Skip to content
New issue

Have a question about this project? Sign up for a free GitHub account to open an issue and contact its maintainers and the community.

By clicking “Sign up for GitHub”, you agree to our terms of service and privacy statement. We’ll occasionally send you account related emails.

Already on GitHub? Sign in to your account

Increase maximum port length from 50 to at least 60 #881

Closed
chrishamm opened this issue Jul 13, 2023 · 2 comments
Closed

Increase maximum port length from 50 to at least 60 #881

chrishamm opened this issue Jul 13, 2023 · 2 comments
Labels
bug Bug that has been reproduced
Milestone

Comments

@chrishamm
Copy link
Collaborator

Under certain circumstances, RRF 3.4 and 3.5 don't allow four pins to be configured at once. See https://forum.duet3d.com/topic/32954/duet-2-wifi-voron-2-4-multiple-z-endstops-query/7?_=1689100174074. That's why we should increase it in 3.4.6-rc.2 and 3.5.0-rc.1.

@chrishamm chrishamm added the bug Bug that has been reproduced label Jul 13, 2023
@chrishamm chrishamm added this to the 3.4.6 milestone Jul 13, 2023
@dc42
Copy link
Collaborator

dc42 commented Jul 18, 2023

Fixed in 3.5-dev today ready fore 3.5.0-rc.1.

@dc42
Copy link
Collaborator

dc42 commented Jul 18, 2023

Also fixed in 3.4-dev ready for 3.4.6-rc.2 or 3.4.6 stable.

@dc42 dc42 closed this as completed Jul 18, 2023
Sign up for free to join this conversation on GitHub. Already have an account? Sign in to comment