From f9bce1e1e9cb9f720b63abef948de7ea2220e861 Mon Sep 17 00:00:00 2001 From: Daniel <139119540+DeltaDaniel@users.noreply.github.com> Date: Wed, 11 Sep 2024 09:13:26 +0200 Subject: [PATCH] test: add more snapshot tests (#429) * WIP * added more snapshottests * fixed paths * try fixing tests * perf(packaging): exclude edi-energy-mirror (#436) exclude edi-energy-mirror * update snapshot * WIP proof of concept * WIP --------- Co-authored-by: kevin Co-authored-by: kevin <68426071+hf-krechan@users.noreply.github.com> --- .github/workflows/checks.yaml | 2 + dev_requirements/requirements-test.txt | 5 + pyproject.toml | 2 +- requirements.txt | 4 + tox.ini | 2 +- unittests/__init__.py | 88 + unittests/__snapshots__/test_ahb.ambr | 490 + .../__snapshots__/test_current_state.ambr | 20373 +++++++++++++--- unittests/test_ahb.py | 39 +- unittests/test_current_state.py | 27 +- 10 files changed, 17482 insertions(+), 3550 deletions(-) create mode 100644 unittests/__snapshots__/test_ahb.ambr diff --git a/.github/workflows/checks.yaml b/.github/workflows/checks.yaml index 7cfd185e..ffd2f0e8 100644 --- a/.github/workflows/checks.yaml +++ b/.github/workflows/checks.yaml @@ -14,6 +14,8 @@ jobs: runs-on: ${{ matrix.os }} steps: - uses: actions/checkout@v4 + with: + submodules: true - name: Set up Python ${{ matrix.python-version }} uses: actions/setup-python@v5 with: diff --git a/dev_requirements/requirements-test.txt b/dev_requirements/requirements-test.txt index 986dadb6..cba85110 100644 --- a/dev_requirements/requirements-test.txt +++ b/dev_requirements/requirements-test.txt @@ -8,6 +8,11 @@ annotated-types==0.7.0 # via pydantic click==8.1.7 # via kohlrahbi (pyproject.toml) +colorama==0.4.6 + # via + # click + # colorlog + # pytest colorlog==6.8.2 # via kohlrahbi (pyproject.toml) coverage==7.6.1 diff --git a/pyproject.toml b/pyproject.toml index 15cf9223..831bab1f 100644 --- a/pyproject.toml +++ b/pyproject.toml @@ -81,7 +81,7 @@ source = "vcs" version-file = "src/kohlrahbi/version.py" [tool.hatch.build.targets.sdist] -exclude = ["/unittests"] +exclude = ["/unittests", "/edi_energy_mirror"] [tool.hatch.build.targets.wheel] only-include = ["src"] diff --git a/requirements.txt b/requirements.txt index a05160a4..32ddf6e9 100644 --- a/requirements.txt +++ b/requirements.txt @@ -8,6 +8,10 @@ annotated-types==0.7.0 # via pydantic click==8.1.7 # via kohlrahbi (pyproject.toml) +colorama==0.4.6 + # via + # click + # colorlog colorlog==6.8.2 # via kohlrahbi (pyproject.toml) efoli==1.1.0 diff --git a/tox.ini b/tox.ini index 2ba39667..78638081 100644 --- a/tox.ini +++ b/tox.ini @@ -25,7 +25,7 @@ deps = -r dev_requirements/requirements-test.txt syrupy setenv = PYTHONPATH = {toxinidir}/src -commands = python -m pytest --basetemp={envtmpdir} {posargs} --snapshot-update +commands = python -m pytest -m snapshot --basetemp={envtmpdir} {posargs} --snapshot-update [testenv:lint] # the lint environment is called by the Github Action that runs the linter diff --git a/unittests/__init__.py b/unittests/__init__.py index 470822ad..f368d28b 100644 --- a/unittests/__init__.py +++ b/unittests/__init__.py @@ -7,3 +7,91 @@ path_to_test_edi_energy_mirror_repo: Path = Path(__file__).parent / "test-edi-energy-mirror-repo" path_to_test_files_fv2310 = path_to_test_edi_energy_mirror_repo / "edi_energy_de" / Path("FV2310") +# list of pruefis to check against in test_current_state +current_state_pruefis = [ + "13002", + "13014", + "13023", + "15002", + "17002", + "17010", + "17114", + "17129", + "17201", + "17208", + "17301", + "19002", + "19007", + "19016", + "19103", + "19120", + "19131", + "19204", + "19301", + "19302", + "21002", + "21010", + "21015", + "21030", + "21039", + "23001", + "23009", + "25001", + "25003", + "25004", + "25006", + "25009", + "27001", + "27003", + "29001", + "29002", + "31001", + "31003", + "31007", + "31011", + "33004", + "35001", + "35004", + "37000", + "37002", + "37005", + "39000", + "39002", + "44001", + "44005", + "44009", + "44016", + "44023", + "44040", + "44053", + "44103", + "44105", + "44112", + "44117", + "44138", + "44140", + "44148", + "44163", + "44180", + "55003", + "55009", + "55014", + "55035", + "55041", + "55062", + "55074", + "55075", + "55077", + "55081", + "55086", + "55093", + "55105", + "55115", + "55127", + "55147", + "55157", + "55182", + "55200", + "55213", + "55555", +] diff --git a/unittests/__snapshots__/test_ahb.ambr b/unittests/__snapshots__/test_ahb.ambr new file mode 100644 index 00000000..4cb89b1c --- /dev/null +++ b/unittests/__snapshots__/test_ahb.ambr @@ -0,0 +1,490 @@ +# serializer version: 1 +# name: TestAhb.test_find_pruefidentifikatoren + dict({ + '13002': 'MSCONSAHB-informatorischeLesefassung3.1cKonsolidierteLesefassungmitFehlerkorrekturenStand12.12.2023_20240402_20231212.docx', + '13003': 'MSCONSAHB-informatorischeLesefassung3.1cKonsolidierteLesefassungmitFehlerkorrekturenStand12.12.2023_20240402_20231212.docx', + '13005': 'MSCONSAHB-informatorischeLesefassung3.1cKonsolidierteLesefassungmitFehlerkorrekturenStand12.12.2023_20240402_20231212.docx', + '13006': 'MSCONSAHB-informatorischeLesefassung3.1cKonsolidierteLesefassungmitFehlerkorrekturenStand12.12.2023_20240402_20231212.docx', + '13007': 'MSCONSAHB-informatorischeLesefassung3.1cKonsolidierteLesefassungmitFehlerkorrekturenStand12.12.2023_20240402_20231212.docx', + '13008': 'MSCONSAHB-informatorischeLesefassung3.1cKonsolidierteLesefassungmitFehlerkorrekturenStand12.12.2023_20240402_20231212.docx', + '13009': 'MSCONSAHB-informatorischeLesefassung3.1cKonsolidierteLesefassungmitFehlerkorrekturenStand12.12.2023_20240402_20231212.docx', + '13010': 'MSCONSAHB-informatorischeLesefassung3.1cKonsolidierteLesefassungmitFehlerkorrekturenStand12.12.2023_20240402_20231212.docx', + '13011': 'MSCONSAHB-informatorischeLesefassung3.1cKonsolidierteLesefassungmitFehlerkorrekturenStand12.12.2023_20240402_20231212.docx', + '13012': 'MSCONSAHB-informatorischeLesefassung3.1cKonsolidierteLesefassungmitFehlerkorrekturenStand12.12.2023_20240402_20231212.docx', + '13013': 'MSCONSAHB-informatorischeLesefassung3.1cKonsolidierteLesefassungmitFehlerkorrekturenStand12.12.2023_20240402_20231212.docx', + '13014': 'MSCONSAHB-informatorischeLesefassung3.1cKonsolidierteLesefassungmitFehlerkorrekturenStand12.12.2023_20240402_20231212.docx', + '13015': 'MSCONSAHB-informatorischeLesefassung3.1cKonsolidierteLesefassungmitFehlerkorrekturenStand12.12.2023_20240402_20231212.docx', + '13016': 'MSCONSAHB-informatorischeLesefassung3.1cKonsolidierteLesefassungmitFehlerkorrekturenStand12.12.2023_20240402_20231212.docx', + '13017': 'MSCONSAHB-informatorischeLesefassung3.1cKonsolidierteLesefassungmitFehlerkorrekturenStand12.12.2023_20240402_20231212.docx', + '13018': 'MSCONSAHB-informatorischeLesefassung3.1cKonsolidierteLesefassungmitFehlerkorrekturenStand12.12.2023_20240402_20231212.docx', + '13019': 'MSCONSAHB-informatorischeLesefassung3.1cKonsolidierteLesefassungmitFehlerkorrekturenStand12.12.2023_20240402_20231212.docx', + '13020': 'MSCONSAHB-informatorischeLesefassung3.1cKonsolidierteLesefassungmitFehlerkorrekturenStand12.12.2023_20240402_20231212.docx', + '13021': 'MSCONSAHB-informatorischeLesefassung3.1cKonsolidierteLesefassungmitFehlerkorrekturenStand12.12.2023_20240402_20231212.docx', + '13022': 'MSCONSAHB-informatorischeLesefassung3.1cKonsolidierteLesefassungmitFehlerkorrekturenStand12.12.2023_20240402_20231212.docx', + '13023': 'MSCONSAHB-informatorischeLesefassung3.1cKonsolidierteLesefassungmitFehlerkorrekturenStand12.12.2023_20240402_20231212.docx', + '13025': 'MSCONSAHB-informatorischeLesefassung3.1cKonsolidierteLesefassungmitFehlerkorrekturenStand12.12.2023_20240402_20231212.docx', + '13026': 'MSCONSAHB-informatorischeLesefassung3.1cKonsolidierteLesefassungmitFehlerkorrekturenStand12.12.2023_20240402_20231212.docx', + '13027': 'MSCONSAHB-informatorischeLesefassung3.1cKonsolidierteLesefassungmitFehlerkorrekturenStand12.12.2023_20240402_20231212.docx', + '15001': 'REQOTEQUOTESORDERSORDRSPORDCHGAHB-informatorischeLesefassung2.3-außerordentlicheVeröffentlichung_20250403_20231001.docx', + '15002': 'REQOTEQUOTESORDERSORDRSPORDCHGAHB-informatorischeLesefassung2.3-außerordentlicheVeröffentlichung_20250403_20231001.docx', + '15003': 'REQOTEQUOTESORDERSORDRSPORDCHGAHB-informatorischeLesefassung2.3-außerordentlicheVeröffentlichung_20250403_20231001.docx', + '15004': 'REQOTEQUOTESORDERSORDRSPORDCHGAHB-informatorischeLesefassung2.3-außerordentlicheVeröffentlichung_20250403_20231001.docx', + '17001': 'REQOTEQUOTESORDERSORDRSPORDCHGAHB-informatorischeLesefassung2.3-außerordentlicheVeröffentlichung_20250403_20231001.docx', + '17002': 'REQOTEQUOTESORDERSORDRSPORDCHGAHB-informatorischeLesefassung2.3-außerordentlicheVeröffentlichung_20250403_20231001.docx', + '17003': 'REQOTEQUOTESORDERSORDRSPORDCHGAHB-informatorischeLesefassung2.3-außerordentlicheVeröffentlichung_20250403_20231001.docx', + '17004': 'REQOTEQUOTESORDERSORDRSPORDCHGAHB-informatorischeLesefassung2.3-außerordentlicheVeröffentlichung_20250403_20231001.docx', + '17005': 'REQOTEQUOTESORDERSORDRSPORDCHGAHB-informatorischeLesefassung2.3-außerordentlicheVeröffentlichung_20250403_20231001.docx', + '17006': 'REQOTEQUOTESORDERSORDRSPORDCHGAHB-informatorischeLesefassung2.3-außerordentlicheVeröffentlichung_20250403_20231001.docx', + '17007': 'REQOTEQUOTESORDERSORDRSPORDCHGAHB-informatorischeLesefassung2.3-außerordentlicheVeröffentlichung_20250403_20231001.docx', + '17008': 'REQOTEQUOTESORDERSORDRSPORDCHGAHB-informatorischeLesefassung2.3-außerordentlicheVeröffentlichung_20250403_20231001.docx', + '17009': 'REQOTEQUOTESORDERSORDRSPORDCHGAHB-informatorischeLesefassung2.3-außerordentlicheVeröffentlichung_20250403_20231001.docx', + '17010': 'REQOTEQUOTESORDERSORDRSPORDCHGAHB-informatorischeLesefassung2.3-außerordentlicheVeröffentlichung_20250403_20231001.docx', + '17101': 'REQOTEQUOTESORDERSORDRSPORDCHGAHB-informatorischeLesefassung2.3-außerordentlicheVeröffentlichung_20250403_20231001.docx', + '17102': 'REQOTEQUOTESORDERSORDRSPORDCHGAHB-informatorischeLesefassung2.3-außerordentlicheVeröffentlichung_20250403_20231001.docx', + '17103': 'REQOTEQUOTESORDERSORDRSPORDCHGAHB-informatorischeLesefassung2.3-außerordentlicheVeröffentlichung_20250403_20231001.docx', + '17104': 'REQOTEQUOTESORDERSORDRSPORDCHGAHB-informatorischeLesefassung2.3-außerordentlicheVeröffentlichung_20250403_20231001.docx', + '17110': 'REQOTEQUOTESORDERSORDRSPORDCHGAHB-informatorischeLesefassung2.3-außerordentlicheVeröffentlichung_20250403_20231001.docx', + '17113': 'REQOTEQUOTESORDERSORDRSPORDCHGAHB-informatorischeLesefassung2.3-außerordentlicheVeröffentlichung_20250403_20231001.docx', + '17114': 'REQOTEQUOTESORDERSORDRSPORDCHGAHB-informatorischeLesefassung2.3-außerordentlicheVeröffentlichung_20250403_20231001.docx', + '17115': 'REQOTEQUOTESORDERSORDRSPORDCHGAHB-informatorischeLesefassung2.3-außerordentlicheVeröffentlichung_20250403_20231001.docx', + '17116': 'REQOTEQUOTESORDERSORDRSPORDCHGAHB-informatorischeLesefassung2.3-außerordentlicheVeröffentlichung_20250403_20231001.docx', + '17117': 'REQOTEQUOTESORDERSORDRSPORDCHGAHB-informatorischeLesefassung2.3-außerordentlicheVeröffentlichung_20250403_20231001.docx', + '17118': 'REQOTEQUOTESORDERSORDRSPORDCHGAHB-informatorischeLesefassung2.3-außerordentlicheVeröffentlichung_20250403_20231001.docx', + '17119': 'REQOTEQUOTESORDERSORDRSPORDCHGAHB-informatorischeLesefassung2.3-außerordentlicheVeröffentlichung_20250403_20231001.docx', + '17120': 'REQOTEQUOTESORDERSORDRSPORDCHGAHB-informatorischeLesefassung2.3-außerordentlicheVeröffentlichung_20250403_20231001.docx', + '17121': 'REQOTEQUOTESORDERSORDRSPORDCHGAHB-informatorischeLesefassung2.3-außerordentlicheVeröffentlichung_20250403_20231001.docx', + '17122': 'REQOTEQUOTESORDERSORDRSPORDCHGAHB-informatorischeLesefassung2.3-außerordentlicheVeröffentlichung_20250403_20231001.docx', + '17123': 'REQOTEQUOTESORDERSORDRSPORDCHGAHB-informatorischeLesefassung2.3-außerordentlicheVeröffentlichung_20250403_20231001.docx', + '17126': 'REQOTEQUOTESORDERSORDRSPORDCHGAHB-informatorischeLesefassung2.3-außerordentlicheVeröffentlichung_20250403_20231001.docx', + '17127': 'REQOTEQUOTESORDERSORDRSPORDCHGAHB-informatorischeLesefassung2.3-außerordentlicheVeröffentlichung_20250403_20231001.docx', + '17128': 'REQOTEQUOTESORDERSORDRSPORDCHGAHB-informatorischeLesefassung2.3-außerordentlicheVeröffentlichung_20250403_20231001.docx', + '17129': 'REQOTEQUOTESORDERSORDRSPORDCHGAHB-informatorischeLesefassung2.3-außerordentlicheVeröffentlichung_20250403_20231001.docx', + '17130': 'REQOTEQUOTESORDERSORDRSPORDCHGAHB-informatorischeLesefassung2.3-außerordentlicheVeröffentlichung_20250403_20231001.docx', + '17131': 'REQOTEQUOTESORDERSORDRSPORDCHGAHB-informatorischeLesefassung2.3-außerordentlicheVeröffentlichung_20250403_20231001.docx', + '17201': 'ORDERSORDRSPAHBMaBiS-informatorischeLesefassung2.2c-außerordentlicheVeröffentlichung_20250403_20231001.docx', + '17202': 'ORDERSORDRSPAHBMaBiS-informatorischeLesefassung2.2c-außerordentlicheVeröffentlichung_20250403_20231001.docx', + '17203': 'ORDERSORDRSPAHBMaBiS-informatorischeLesefassung2.2c-außerordentlicheVeröffentlichung_20250403_20231001.docx', + '17204': 'ORDERSORDRSPAHBMaBiS-informatorischeLesefassung2.2c-außerordentlicheVeröffentlichung_20250403_20231001.docx', + '17205': 'ORDERSORDRSPAHBMaBiS-informatorischeLesefassung2.2c-außerordentlicheVeröffentlichung_20250403_20231001.docx', + '17206': 'ORDERSORDRSPAHBMaBiS-informatorischeLesefassung2.2c-außerordentlicheVeröffentlichung_20250403_20231001.docx', + '17207': 'ORDERSORDRSPAHBMaBiS-informatorischeLesefassung2.2c-außerordentlicheVeröffentlichung_20250403_20231001.docx', + '17208': 'ORDERSORDRSPAHBMaBiS-informatorischeLesefassung2.2c-außerordentlicheVeröffentlichung_20250403_20231001.docx', + '17209': 'ORDERSORDRSPAHBMaBiS-informatorischeLesefassung2.2c-außerordentlicheVeröffentlichung_20250403_20231001.docx', + '17210': 'ORDERSORDRSPAHBMaBiS-informatorischeLesefassung2.2c-außerordentlicheVeröffentlichung_20250403_20231001.docx', + '17211': 'ORDERSORDRSPAHBMaBiS-informatorischeLesefassung2.2c-außerordentlicheVeröffentlichung_20250403_20231001.docx', + '17301': 'HerkunftsnachweisregisterAHB-informatorischeLesefassung2.3cKonsolidierteLesefassungmitFehlerkorrekturenStand19.06.2023_20240402_20231001.docx', + '19001': 'REQOTEQUOTESORDERSORDRSPORDCHGAHB-informatorischeLesefassung2.3-außerordentlicheVeröffentlichung_20250403_20231001.docx', + '19002': 'REQOTEQUOTESORDERSORDRSPORDCHGAHB-informatorischeLesefassung2.3-außerordentlicheVeröffentlichung_20250403_20231001.docx', + '19003': 'REQOTEQUOTESORDERSORDRSPORDCHGAHB-informatorischeLesefassung2.3-außerordentlicheVeröffentlichung_20250403_20231001.docx', + '19004': 'REQOTEQUOTESORDERSORDRSPORDCHGAHB-informatorischeLesefassung2.3-außerordentlicheVeröffentlichung_20250403_20231001.docx', + '19005': 'REQOTEQUOTESORDERSORDRSPORDCHGAHB-informatorischeLesefassung2.3-außerordentlicheVeröffentlichung_20250403_20231001.docx', + '19006': 'REQOTEQUOTESORDERSORDRSPORDCHGAHB-informatorischeLesefassung2.3-außerordentlicheVeröffentlichung_20250403_20231001.docx', + '19007': 'REQOTEQUOTESORDERSORDRSPORDCHGAHB-informatorischeLesefassung2.3-außerordentlicheVeröffentlichung_20250403_20231001.docx', + '19009': 'REQOTEQUOTESORDERSORDRSPORDCHGAHB-informatorischeLesefassung2.3-außerordentlicheVeröffentlichung_20250403_20231001.docx', + '19010': 'REQOTEQUOTESORDERSORDRSPORDCHGAHB-informatorischeLesefassung2.3-außerordentlicheVeröffentlichung_20250403_20231001.docx', + '19011': 'REQOTEQUOTESORDERSORDRSPORDCHGAHB-informatorischeLesefassung2.3-außerordentlicheVeröffentlichung_20250403_20231001.docx', + '19012': 'REQOTEQUOTESORDERSORDRSPORDCHGAHB-informatorischeLesefassung2.3-außerordentlicheVeröffentlichung_20250403_20231001.docx', + '19013': 'REQOTEQUOTESORDERSORDRSPORDCHGAHB-informatorischeLesefassung2.3-außerordentlicheVeröffentlichung_20250403_20231001.docx', + '19014': 'REQOTEQUOTESORDERSORDRSPORDCHGAHB-informatorischeLesefassung2.3-außerordentlicheVeröffentlichung_20250403_20231001.docx', + '19015': 'REQOTEQUOTESORDERSORDRSPORDCHGAHB-informatorischeLesefassung2.3-außerordentlicheVeröffentlichung_20250403_20231001.docx', + '19016': 'REQOTEQUOTESORDERSORDRSPORDCHGAHB-informatorischeLesefassung2.3-außerordentlicheVeröffentlichung_20250403_20231001.docx', + '19017': 'REQOTEQUOTESORDERSORDRSPORDCHGAHB-informatorischeLesefassung2.3-außerordentlicheVeröffentlichung_20250403_20231001.docx', + '19101': 'REQOTEQUOTESORDERSORDRSPORDCHGAHB-informatorischeLesefassung2.3-außerordentlicheVeröffentlichung_20250403_20231001.docx', + '19102': 'REQOTEQUOTESORDERSORDRSPORDCHGAHB-informatorischeLesefassung2.3-außerordentlicheVeröffentlichung_20250403_20231001.docx', + '19103': 'REQOTEQUOTESORDERSORDRSPORDCHGAHB-informatorischeLesefassung2.3-außerordentlicheVeröffentlichung_20250403_20231001.docx', + '19104': 'REQOTEQUOTESORDERSORDRSPORDCHGAHB-informatorischeLesefassung2.3-außerordentlicheVeröffentlichung_20250403_20231001.docx', + '19110': 'REQOTEQUOTESORDERSORDRSPORDCHGAHB-informatorischeLesefassung2.3-außerordentlicheVeröffentlichung_20250403_20231001.docx', + '19114': 'REQOTEQUOTESORDERSORDRSPORDCHGAHB-informatorischeLesefassung2.3-außerordentlicheVeröffentlichung_20250403_20231001.docx', + '19115': 'REQOTEQUOTESORDERSORDRSPORDCHGAHB-informatorischeLesefassung2.3-außerordentlicheVeröffentlichung_20250403_20231001.docx', + '19116': 'REQOTEQUOTESORDERSORDRSPORDCHGAHB-informatorischeLesefassung2.3-außerordentlicheVeröffentlichung_20250403_20231001.docx', + '19117': 'REQOTEQUOTESORDERSORDRSPORDCHGAHB-informatorischeLesefassung2.3-außerordentlicheVeröffentlichung_20250403_20231001.docx', + '19118': 'REQOTEQUOTESORDERSORDRSPORDCHGAHB-informatorischeLesefassung2.3-außerordentlicheVeröffentlichung_20250403_20231001.docx', + '19119': 'REQOTEQUOTESORDERSORDRSPORDCHGAHB-informatorischeLesefassung2.3-außerordentlicheVeröffentlichung_20250403_20231001.docx', + '19120': 'REQOTEQUOTESORDERSORDRSPORDCHGAHB-informatorischeLesefassung2.3-außerordentlicheVeröffentlichung_20250403_20231001.docx', + '19121': 'REQOTEQUOTESORDERSORDRSPORDCHGAHB-informatorischeLesefassung2.3-außerordentlicheVeröffentlichung_20250403_20231001.docx', + '19122': 'REQOTEQUOTESORDERSORDRSPORDCHGAHB-informatorischeLesefassung2.3-außerordentlicheVeröffentlichung_20250403_20231001.docx', + '19123': 'REQOTEQUOTESORDERSORDRSPORDCHGAHB-informatorischeLesefassung2.3-außerordentlicheVeröffentlichung_20250403_20231001.docx', + '19124': 'REQOTEQUOTESORDERSORDRSPORDCHGAHB-informatorischeLesefassung2.3-außerordentlicheVeröffentlichung_20250403_20231001.docx', + '19127': 'REQOTEQUOTESORDERSORDRSPORDCHGAHB-informatorischeLesefassung2.3-außerordentlicheVeröffentlichung_20250403_20231001.docx', + '19128': 'REQOTEQUOTESORDERSORDRSPORDCHGAHB-informatorischeLesefassung2.3-außerordentlicheVeröffentlichung_20250403_20231001.docx', + '19129': 'REQOTEQUOTESORDERSORDRSPORDCHGAHB-informatorischeLesefassung2.3-außerordentlicheVeröffentlichung_20250403_20231001.docx', + '19130': 'REQOTEQUOTESORDERSORDRSPORDCHGAHB-informatorischeLesefassung2.3-außerordentlicheVeröffentlichung_20250403_20231001.docx', + '19131': 'REQOTEQUOTESORDERSORDRSPORDCHGAHB-informatorischeLesefassung2.3-außerordentlicheVeröffentlichung_20250403_20231001.docx', + '19132': 'REQOTEQUOTESORDERSORDRSPORDCHGAHB-informatorischeLesefassung2.3-außerordentlicheVeröffentlichung_20250403_20231001.docx', + '19204': 'ORDERSORDRSPAHBMaBiS-informatorischeLesefassung2.2c-außerordentlicheVeröffentlichung_20250403_20231001.docx', + '19301': 'HerkunftsnachweisregisterAHB-informatorischeLesefassung2.3cKonsolidierteLesefassungmitFehlerkorrekturenStand19.06.2023_20240402_20231001.docx', + '19302': 'HerkunftsnachweisregisterAHB-informatorischeLesefassung2.3cKonsolidierteLesefassungmitFehlerkorrekturenStand19.06.2023_20240402_20231001.docx', + '21000': 'IFTSTAAHB-informatorischeLesefassung2.0e-außerordentlicheVeröffentlichung_20250403_20240311.docx', + '21001': 'IFTSTAAHB-informatorischeLesefassung2.0e-außerordentlicheVeröffentlichung_20250403_20240311.docx', + '21002': 'IFTSTAAHB-informatorischeLesefassung2.0e-außerordentlicheVeröffentlichung_20250403_20240311.docx', + '21003': 'IFTSTAAHB-informatorischeLesefassung2.0e-außerordentlicheVeröffentlichung_20250403_20240311.docx', + '21004': 'IFTSTAAHB-informatorischeLesefassung2.0e-außerordentlicheVeröffentlichung_20250403_20240311.docx', + '21005': 'IFTSTAAHB-informatorischeLesefassung2.0e-außerordentlicheVeröffentlichung_20250403_20240311.docx', + '21007': 'IFTSTAAHB-informatorischeLesefassung2.0e-außerordentlicheVeröffentlichung_20250403_20240311.docx', + '21009': 'IFTSTAAHB-informatorischeLesefassung2.0e-außerordentlicheVeröffentlichung_20250403_20240311.docx', + '21010': 'IFTSTAAHB-informatorischeLesefassung2.0e-außerordentlicheVeröffentlichung_20250403_20240311.docx', + '21011': 'IFTSTAAHB-informatorischeLesefassung2.0e-außerordentlicheVeröffentlichung_20250403_20240311.docx', + '21012': 'IFTSTAAHB-informatorischeLesefassung2.0e-außerordentlicheVeröffentlichung_20250403_20240311.docx', + '21013': 'IFTSTAAHB-informatorischeLesefassung2.0e-außerordentlicheVeröffentlichung_20250403_20240311.docx', + '21015': 'IFTSTAAHB-informatorischeLesefassung2.0e-außerordentlicheVeröffentlichung_20250403_20240311.docx', + '21018': 'IFTSTAAHB-informatorischeLesefassung2.0e-außerordentlicheVeröffentlichung_20250403_20240311.docx', + '21024': 'IFTSTAAHB-informatorischeLesefassung2.0e-außerordentlicheVeröffentlichung_20250403_20240311.docx', + '21025': 'IFTSTAAHB-informatorischeLesefassung2.0e-außerordentlicheVeröffentlichung_20250403_20240311.docx', + '21026': 'IFTSTAAHB-informatorischeLesefassung2.0e-außerordentlicheVeröffentlichung_20250403_20240311.docx', + '21027': 'IFTSTAAHB-informatorischeLesefassung2.0e-außerordentlicheVeröffentlichung_20250403_20240311.docx', + '21028': 'IFTSTAAHB-informatorischeLesefassung2.0e-außerordentlicheVeröffentlichung_20250403_20240311.docx', + '21029': 'IFTSTAAHB-informatorischeLesefassung2.0e-außerordentlicheVeröffentlichung_20250403_20240311.docx', + '21030': 'IFTSTAAHB-informatorischeLesefassung2.0e-außerordentlicheVeröffentlichung_20250403_20240311.docx', + '21031': 'IFTSTAAHB-informatorischeLesefassung2.0e-außerordentlicheVeröffentlichung_20250403_20240311.docx', + '21032': 'IFTSTAAHB-informatorischeLesefassung2.0e-außerordentlicheVeröffentlichung_20250403_20240311.docx', + '21033': 'IFTSTAAHB-informatorischeLesefassung2.0e-außerordentlicheVeröffentlichung_20250403_20240311.docx', + '21035': 'IFTSTAAHB-informatorischeLesefassung2.0e-außerordentlicheVeröffentlichung_20250403_20240311.docx', + '21036': 'IFTSTAAHB-informatorischeLesefassung2.0e-außerordentlicheVeröffentlichung_20250403_20240311.docx', + '21037': 'IFTSTAAHB-informatorischeLesefassung2.0e-außerordentlicheVeröffentlichung_20250403_20240311.docx', + '21038': 'IFTSTAAHB-informatorischeLesefassung2.0e-außerordentlicheVeröffentlichung_20250403_20240311.docx', + '21039': 'IFTSTAAHB-informatorischeLesefassung2.0e-außerordentlicheVeröffentlichung_20250403_20240311.docx', + '21040': 'IFTSTAAHB-informatorischeLesefassung2.0e-außerordentlicheVeröffentlichung_20250403_20240311.docx', + '21042': 'IFTSTAAHB-informatorischeLesefassung2.0e-außerordentlicheVeröffentlichung_20250403_20240311.docx', + '21043': 'IFTSTAAHB-informatorischeLesefassung2.0e-außerordentlicheVeröffentlichung_20250403_20240311.docx', + '21044': 'IFTSTAAHB-informatorischeLesefassung2.0e-außerordentlicheVeröffentlichung_20250403_20240311.docx', + '21045': 'IFTSTAAHB-informatorischeLesefassung2.0e-außerordentlicheVeröffentlichung_20250403_20240311.docx', + '23001': 'INSRPTAHB-informatorischeLesefassung1.1g-außerordentlicheVeröffentlichung_99991231_20230330.docx', + '23003': 'INSRPTAHB-informatorischeLesefassung1.1g-außerordentlicheVeröffentlichung_99991231_20230330.docx', + '23004': 'INSRPTAHB-informatorischeLesefassung1.1g-außerordentlicheVeröffentlichung_99991231_20230330.docx', + '23005': 'INSRPTAHB-informatorischeLesefassung1.1g-außerordentlicheVeröffentlichung_99991231_20230330.docx', + '23008': 'INSRPTAHB-informatorischeLesefassung1.1g-außerordentlicheVeröffentlichung_99991231_20230330.docx', + '23009': 'INSRPTAHB-informatorischeLesefassung1.1g-außerordentlicheVeröffentlichung_99991231_20230330.docx', + '23011': 'INSRPTAHB-informatorischeLesefassung1.1g-außerordentlicheVeröffentlichung_99991231_20230330.docx', + '23012': 'INSRPTAHB-informatorischeLesefassung1.1g-außerordentlicheVeröffentlichung_99991231_20230330.docx', + '25001': 'UTILTSAHBBerechnungsformel-informatorischeLesefassung1.0e_20240402_20231001.docx', + '25002': 'UTILTSAHBBerechnungsformel-informatorischeLesefassung1.0e_20240402_20231001.docx', + '25003': 'UTILTSAHBBerechnungsformel-informatorischeLesefassung1.0e_20240402_20231001.docx', + '25004': 'UTILTSAHBDefinitionen-informatorischeLesefassung1.1KonsolidierteLesefassungmitFehlerkorrekturenStand12.12.2023_20240402_20231212.docx', + '25005': 'UTILTSAHBDefinitionen-informatorischeLesefassung1.1KonsolidierteLesefassungmitFehlerkorrekturenStand12.12.2023_20240402_20231212.docx', + '25006': 'UTILTSAHBDefinitionen-informatorischeLesefassung1.1KonsolidierteLesefassungmitFehlerkorrekturenStand12.12.2023_20240402_20231212.docx', + '25007': 'UTILTSAHBDefinitionen-informatorischeLesefassung1.1KonsolidierteLesefassungmitFehlerkorrekturenStand12.12.2023_20240402_20231212.docx', + '25008': 'UTILTSAHBDefinitionen-informatorischeLesefassung1.1KonsolidierteLesefassungmitFehlerkorrekturenStand12.12.2023_20240402_20231212.docx', + '25009': 'UTILTSAHBDefinitionen-informatorischeLesefassung1.1KonsolidierteLesefassungmitFehlerkorrekturenStand12.12.2023_20240402_20231212.docx', + '27001': 'PRICATAHB-informatorischeLesefassung2.0c_20240402_20231001.docx', + '27002': 'PRICATAHB-informatorischeLesefassung2.0c_20240402_20231001.docx', + '27003': 'PRICATAHB-informatorischeLesefassung2.0c_20240402_20231001.docx', + '29001': 'COMDISAHB-informatorischeLesefassung1.0dKonsolidierteLesefassungmitFehlerkorrekturenStand20.07.2023_20240402_20231001.docx', + '29002': 'COMDISAHB-informatorischeLesefassung1.0dKonsolidierteLesefassungmitFehlerkorrekturenStand20.07.2023_20240402_20231001.docx', + '31001': 'INVOICREMADVAHB-informatorischeLesefassung2.5bKonsolidierteLesefassungmitFehlerkorrekturenStand23.10.2023_20240402_20231023.docx', + '31002': 'INVOICREMADVAHB-informatorischeLesefassung2.5bKonsolidierteLesefassungmitFehlerkorrekturenStand23.10.2023_20240402_20231023.docx', + '31003': 'INVOICREMADVAHB-informatorischeLesefassung2.5bKonsolidierteLesefassungmitFehlerkorrekturenStand23.10.2023_20240402_20231023.docx', + '31004': 'INVOICREMADVAHB-informatorischeLesefassung2.5bKonsolidierteLesefassungmitFehlerkorrekturenStand23.10.2023_20240402_20231023.docx', + '31005': 'INVOICREMADVAHB-informatorischeLesefassung2.5bKonsolidierteLesefassungmitFehlerkorrekturenStand23.10.2023_20240402_20231023.docx', + '31006': 'INVOICREMADVAHB-informatorischeLesefassung2.5bKonsolidierteLesefassungmitFehlerkorrekturenStand23.10.2023_20240402_20231023.docx', + '31007': 'INVOICREMADVAHB-informatorischeLesefassung2.5bKonsolidierteLesefassungmitFehlerkorrekturenStand23.10.2023_20240402_20231023.docx', + '31008': 'INVOICREMADVAHB-informatorischeLesefassung2.5bKonsolidierteLesefassungmitFehlerkorrekturenStand23.10.2023_20240402_20231023.docx', + '31009': 'INVOICREMADVAHB-informatorischeLesefassung2.5bKonsolidierteLesefassungmitFehlerkorrekturenStand23.10.2023_20240402_20231023.docx', + '31010': 'INVOICREMADVAHB-informatorischeLesefassung2.5bKonsolidierteLesefassungmitFehlerkorrekturenStand23.10.2023_20240402_20231023.docx', + '31011': 'INVOICREMADVAHB-informatorischeLesefassung2.5bKonsolidierteLesefassungmitFehlerkorrekturenStand23.10.2023_20240402_20231023.docx', + '33001': 'INVOICREMADVAHB-informatorischeLesefassung2.5bKonsolidierteLesefassungmitFehlerkorrekturenStand23.10.2023_20240402_20231023.docx', + '33002': 'INVOICREMADVAHB-informatorischeLesefassung2.5bKonsolidierteLesefassungmitFehlerkorrekturenStand23.10.2023_20240402_20231023.docx', + '33003': 'INVOICREMADVAHB-informatorischeLesefassung2.5bKonsolidierteLesefassungmitFehlerkorrekturenStand23.10.2023_20240402_20231023.docx', + '33004': 'INVOICREMADVAHB-informatorischeLesefassung2.5bKonsolidierteLesefassungmitFehlerkorrekturenStand23.10.2023_20240402_20231023.docx', + '35001': 'REQOTEQUOTESORDERSORDRSPORDCHGAHB-informatorischeLesefassung2.3-außerordentlicheVeröffentlichung_20250403_20231001.docx', + '35002': 'REQOTEQUOTESORDERSORDRSPORDCHGAHB-informatorischeLesefassung2.3-außerordentlicheVeröffentlichung_20250403_20231001.docx', + '35003': 'REQOTEQUOTESORDERSORDRSPORDCHGAHB-informatorischeLesefassung2.3-außerordentlicheVeröffentlichung_20250403_20231001.docx', + '35004': 'REQOTEQUOTESORDERSORDRSPORDCHGAHB-informatorischeLesefassung2.3-außerordentlicheVeröffentlichung_20250403_20231001.docx', + '37000': 'PARTINAHB-informatorischeLesefassung1.0cKonsolidierteLesefassungmitFehlerkorrekturenStand29.09.2023_20240402_20231001.docx', + '37001': 'PARTINAHB-informatorischeLesefassung1.0cKonsolidierteLesefassungmitFehlerkorrekturenStand29.09.2023_20240402_20231001.docx', + '37002': 'PARTINAHB-informatorischeLesefassung1.0cKonsolidierteLesefassungmitFehlerkorrekturenStand29.09.2023_20240402_20231001.docx', + '37003': 'PARTINAHB-informatorischeLesefassung1.0cKonsolidierteLesefassungmitFehlerkorrekturenStand29.09.2023_20240402_20231001.docx', + '37004': 'PARTINAHB-informatorischeLesefassung1.0cKonsolidierteLesefassungmitFehlerkorrekturenStand29.09.2023_20240402_20231001.docx', + '37005': 'PARTINAHB-informatorischeLesefassung1.0cKonsolidierteLesefassungmitFehlerkorrekturenStand29.09.2023_20240402_20231001.docx', + '37006': 'PARTINAHB-informatorischeLesefassung1.0cKonsolidierteLesefassungmitFehlerkorrekturenStand29.09.2023_20240402_20231001.docx', + '37007': 'PARTINAHB-informatorischeLesefassung1.0cKonsolidierteLesefassungmitFehlerkorrekturenStand29.09.2023_20240402_20231001.docx', + '39000': 'REQOTEQUOTESORDERSORDRSPORDCHGAHB-informatorischeLesefassung2.3-außerordentlicheVeröffentlichung_20250403_20231001.docx', + '39001': 'REQOTEQUOTESORDERSORDRSPORDCHGAHB-informatorischeLesefassung2.3-außerordentlicheVeröffentlichung_20250403_20231001.docx', + '39002': 'REQOTEQUOTESORDERSORDRSPORDCHGAHB-informatorischeLesefassung2.3-außerordentlicheVeröffentlichung_20250403_20231001.docx', + '44001': 'UTILMDAHBGas-informatorischeLesefassung1.0a-außerordentlicheVeröffentlichung_99991231_20231212.docx', + '44002': 'UTILMDAHBGas-informatorischeLesefassung1.0a-außerordentlicheVeröffentlichung_99991231_20231212.docx', + '44003': 'UTILMDAHBGas-informatorischeLesefassung1.0a-außerordentlicheVeröffentlichung_99991231_20231212.docx', + '44004': 'UTILMDAHBGas-informatorischeLesefassung1.0a-außerordentlicheVeröffentlichung_99991231_20231212.docx', + '44005': 'UTILMDAHBGas-informatorischeLesefassung1.0a-außerordentlicheVeröffentlichung_99991231_20231212.docx', + '44006': 'UTILMDAHBGas-informatorischeLesefassung1.0a-außerordentlicheVeröffentlichung_99991231_20231212.docx', + '44007': 'UTILMDAHBGas-informatorischeLesefassung1.0a-außerordentlicheVeröffentlichung_99991231_20231212.docx', + '44008': 'UTILMDAHBGas-informatorischeLesefassung1.0a-außerordentlicheVeröffentlichung_99991231_20231212.docx', + '44009': 'UTILMDAHBGas-informatorischeLesefassung1.0a-außerordentlicheVeröffentlichung_99991231_20231212.docx', + '44010': 'UTILMDAHBGas-informatorischeLesefassung1.0a-außerordentlicheVeröffentlichung_99991231_20231212.docx', + '44011': 'UTILMDAHBGas-informatorischeLesefassung1.0a-außerordentlicheVeröffentlichung_99991231_20231212.docx', + '44012': 'UTILMDAHBGas-informatorischeLesefassung1.0a-außerordentlicheVeröffentlichung_99991231_20231212.docx', + '44013': 'UTILMDAHBGas-informatorischeLesefassung1.0a-außerordentlicheVeröffentlichung_99991231_20231212.docx', + '44014': 'UTILMDAHBGas-informatorischeLesefassung1.0a-außerordentlicheVeröffentlichung_99991231_20231212.docx', + '44015': 'UTILMDAHBGas-informatorischeLesefassung1.0a-außerordentlicheVeröffentlichung_99991231_20231212.docx', + '44016': 'UTILMDAHBGas-informatorischeLesefassung1.0a-außerordentlicheVeröffentlichung_99991231_20231212.docx', + '44017': 'UTILMDAHBGas-informatorischeLesefassung1.0a-außerordentlicheVeröffentlichung_99991231_20231212.docx', + '44018': 'UTILMDAHBGas-informatorischeLesefassung1.0a-außerordentlicheVeröffentlichung_99991231_20231212.docx', + '44019': 'UTILMDAHBGas-informatorischeLesefassung1.0a-außerordentlicheVeröffentlichung_99991231_20231212.docx', + '44020': 'UTILMDAHBGas-informatorischeLesefassung1.0a-außerordentlicheVeröffentlichung_99991231_20231212.docx', + '44021': 'UTILMDAHBGas-informatorischeLesefassung1.0a-außerordentlicheVeröffentlichung_99991231_20231212.docx', + '44022': 'UTILMDAHBGas-informatorischeLesefassung1.0a-außerordentlicheVeröffentlichung_99991231_20231212.docx', + '44023': 'UTILMDAHBGas-informatorischeLesefassung1.0a-außerordentlicheVeröffentlichung_99991231_20231212.docx', + '44024': 'UTILMDAHBGas-informatorischeLesefassung1.0a-außerordentlicheVeröffentlichung_99991231_20231212.docx', + '44035': 'UTILMDAHBGas-informatorischeLesefassung1.0a-außerordentlicheVeröffentlichung_99991231_20231212.docx', + '44036': 'UTILMDAHBGas-informatorischeLesefassung1.0a-außerordentlicheVeröffentlichung_99991231_20231212.docx', + '44037': 'UTILMDAHBGas-informatorischeLesefassung1.0a-außerordentlicheVeröffentlichung_99991231_20231212.docx', + '44038': 'UTILMDAHBGas-informatorischeLesefassung1.0a-außerordentlicheVeröffentlichung_99991231_20231212.docx', + '44039': 'UTILMDAHBGas-informatorischeLesefassung1.0a-außerordentlicheVeröffentlichung_99991231_20231212.docx', + '44040': 'UTILMDAHBGas-informatorischeLesefassung1.0a-außerordentlicheVeröffentlichung_99991231_20231212.docx', + '44041': 'UTILMDAHBGas-informatorischeLesefassung1.0a-außerordentlicheVeröffentlichung_99991231_20231212.docx', + '44042': 'UTILMDAHBGas-informatorischeLesefassung1.0a-außerordentlicheVeröffentlichung_99991231_20231212.docx', + '44043': 'UTILMDAHBGas-informatorischeLesefassung1.0a-außerordentlicheVeröffentlichung_99991231_20231212.docx', + '44044': 'UTILMDAHBGas-informatorischeLesefassung1.0a-außerordentlicheVeröffentlichung_99991231_20231212.docx', + '44051': 'UTILMDAHBGas-informatorischeLesefassung1.0a-außerordentlicheVeröffentlichung_99991231_20231212.docx', + '44052': 'UTILMDAHBGas-informatorischeLesefassung1.0a-außerordentlicheVeröffentlichung_99991231_20231212.docx', + '44053': 'UTILMDAHBGas-informatorischeLesefassung1.0a-außerordentlicheVeröffentlichung_99991231_20231212.docx', + '44060': 'UTILMDAHBGas-informatorischeLesefassung1.0a-außerordentlicheVeröffentlichung_99991231_20231212.docx', + '44101': 'UTILMDAHBGas-informatorischeLesefassung1.0a-außerordentlicheVeröffentlichung_99991231_20231212.docx', + '44102': 'UTILMDAHBGas-informatorischeLesefassung1.0a-außerordentlicheVeröffentlichung_99991231_20231212.docx', + '44103': 'UTILMDAHBGas-informatorischeLesefassung1.0a-außerordentlicheVeröffentlichung_99991231_20231212.docx', + '44104': 'UTILMDAHBGas-informatorischeLesefassung1.0a-außerordentlicheVeröffentlichung_99991231_20231212.docx', + '44105': 'UTILMDAHBGas-informatorischeLesefassung1.0a-außerordentlicheVeröffentlichung_99991231_20231212.docx', + '44109': 'UTILMDAHBGas-informatorischeLesefassung1.0a-außerordentlicheVeröffentlichung_99991231_20231212.docx', + '44111': 'UTILMDAHBGas-informatorischeLesefassung1.0a-außerordentlicheVeröffentlichung_99991231_20231212.docx', + '44112': 'UTILMDAHBGas-informatorischeLesefassung1.0a-außerordentlicheVeröffentlichung_99991231_20231212.docx', + '44113': 'UTILMDAHBGas-informatorischeLesefassung1.0a-außerordentlicheVeröffentlichung_99991231_20231212.docx', + '44115': 'UTILMDAHBGas-informatorischeLesefassung1.0a-außerordentlicheVeröffentlichung_99991231_20231212.docx', + '44116': 'UTILMDAHBGas-informatorischeLesefassung1.0a-außerordentlicheVeröffentlichung_99991231_20231212.docx', + '44117': 'UTILMDAHBGas-informatorischeLesefassung1.0a-außerordentlicheVeröffentlichung_99991231_20231212.docx', + '44119': 'UTILMDAHBGas-informatorischeLesefassung1.0a-außerordentlicheVeröffentlichung_99991231_20231212.docx', + '44120': 'UTILMDAHBGas-informatorischeLesefassung1.0a-außerordentlicheVeröffentlichung_99991231_20231212.docx', + '44121': 'UTILMDAHBGas-informatorischeLesefassung1.0a-außerordentlicheVeröffentlichung_99991231_20231212.docx', + '44123': 'UTILMDAHBGas-informatorischeLesefassung1.0a-außerordentlicheVeröffentlichung_99991231_20231212.docx', + '44124': 'UTILMDAHBGas-informatorischeLesefassung1.0a-außerordentlicheVeröffentlichung_99991231_20231212.docx', + '44137': 'UTILMDAHBGas-informatorischeLesefassung1.0a-außerordentlicheVeröffentlichung_99991231_20231212.docx', + '44138': 'UTILMDAHBGas-informatorischeLesefassung1.0a-außerordentlicheVeröffentlichung_99991231_20231212.docx', + '44139': 'UTILMDAHBGas-informatorischeLesefassung1.0a-außerordentlicheVeröffentlichung_99991231_20231212.docx', + '44140': 'UTILMDAHBGas-informatorischeLesefassung1.0a-außerordentlicheVeröffentlichung_99991231_20231212.docx', + '44142': 'UTILMDAHBGas-informatorischeLesefassung1.0a-außerordentlicheVeröffentlichung_99991231_20231212.docx', + '44143': 'UTILMDAHBGas-informatorischeLesefassung1.0a-außerordentlicheVeröffentlichung_99991231_20231212.docx', + '44145': 'UTILMDAHBGas-informatorischeLesefassung1.0a-außerordentlicheVeröffentlichung_99991231_20231212.docx', + '44146': 'UTILMDAHBGas-informatorischeLesefassung1.0a-außerordentlicheVeröffentlichung_99991231_20231212.docx', + '44147': 'UTILMDAHBGas-informatorischeLesefassung1.0a-außerordentlicheVeröffentlichung_99991231_20231212.docx', + '44148': 'UTILMDAHBGas-informatorischeLesefassung1.0a-außerordentlicheVeröffentlichung_99991231_20231212.docx', + '44149': 'UTILMDAHBGas-informatorischeLesefassung1.0a-außerordentlicheVeröffentlichung_99991231_20231212.docx', + '44150': 'UTILMDAHBGas-informatorischeLesefassung1.0a-außerordentlicheVeröffentlichung_99991231_20231212.docx', + '44151': 'UTILMDAHBGas-informatorischeLesefassung1.0a-außerordentlicheVeröffentlichung_99991231_20231212.docx', + '44152': 'UTILMDAHBGas-informatorischeLesefassung1.0a-außerordentlicheVeröffentlichung_99991231_20231212.docx', + '44156': 'UTILMDAHBGas-informatorischeLesefassung1.0a-außerordentlicheVeröffentlichung_99991231_20231212.docx', + '44157': 'UTILMDAHBGas-informatorischeLesefassung1.0a-außerordentlicheVeröffentlichung_99991231_20231212.docx', + '44159': 'UTILMDAHBGas-informatorischeLesefassung1.0a-außerordentlicheVeröffentlichung_99991231_20231212.docx', + '44160': 'UTILMDAHBGas-informatorischeLesefassung1.0a-außerordentlicheVeröffentlichung_99991231_20231212.docx', + '44161': 'UTILMDAHBGas-informatorischeLesefassung1.0a-außerordentlicheVeröffentlichung_99991231_20231212.docx', + '44162': 'UTILMDAHBGas-informatorischeLesefassung1.0a-außerordentlicheVeröffentlichung_99991231_20231212.docx', + '44163': 'UTILMDAHBGas-informatorischeLesefassung1.0a-außerordentlicheVeröffentlichung_99991231_20231212.docx', + '44164': 'UTILMDAHBGas-informatorischeLesefassung1.0a-außerordentlicheVeröffentlichung_99991231_20231212.docx', + '44165': 'UTILMDAHBGas-informatorischeLesefassung1.0a-außerordentlicheVeröffentlichung_99991231_20231212.docx', + '44166': 'UTILMDAHBGas-informatorischeLesefassung1.0a-außerordentlicheVeröffentlichung_99991231_20231212.docx', + '44167': 'UTILMDAHBGas-informatorischeLesefassung1.0a-außerordentlicheVeröffentlichung_99991231_20231212.docx', + '44168': 'UTILMDAHBGas-informatorischeLesefassung1.0a-außerordentlicheVeröffentlichung_99991231_20231212.docx', + '44169': 'UTILMDAHBGas-informatorischeLesefassung1.0a-außerordentlicheVeröffentlichung_99991231_20231212.docx', + '44170': 'UTILMDAHBGas-informatorischeLesefassung1.0a-außerordentlicheVeröffentlichung_99991231_20231212.docx', + '44175': 'UTILMDAHBGas-informatorischeLesefassung1.0a-außerordentlicheVeröffentlichung_99991231_20231212.docx', + '44176': 'UTILMDAHBGas-informatorischeLesefassung1.0a-außerordentlicheVeröffentlichung_99991231_20231212.docx', + '44180': 'UTILMDAHBGas-informatorischeLesefassung1.0a-außerordentlicheVeröffentlichung_99991231_20231212.docx', + '44181': 'UTILMDAHBGas-informatorischeLesefassung1.0a-außerordentlicheVeröffentlichung_99991231_20231212.docx', + '44182': 'UTILMDAHBGas-informatorischeLesefassung1.0a-außerordentlicheVeröffentlichung_99991231_20231212.docx', + '55001': 'UTILMDAHBStrom-informatorischeLesefassung1.1KonsolidierteLesefassungmitFehlerkorrekturenStand12.12.2023_20240402_20231212.docx', + '55002': 'UTILMDAHBStrom-informatorischeLesefassung1.1KonsolidierteLesefassungmitFehlerkorrekturenStand12.12.2023_20240402_20231212.docx', + '55003': 'UTILMDAHBStrom-informatorischeLesefassung1.1KonsolidierteLesefassungmitFehlerkorrekturenStand12.12.2023_20240402_20231212.docx', + '55004': 'UTILMDAHBStrom-informatorischeLesefassung1.1KonsolidierteLesefassungmitFehlerkorrekturenStand12.12.2023_20240402_20231212.docx', + '55005': 'UTILMDAHBStrom-informatorischeLesefassung1.1KonsolidierteLesefassungmitFehlerkorrekturenStand12.12.2023_20240402_20231212.docx', + '55006': 'UTILMDAHBStrom-informatorischeLesefassung1.1KonsolidierteLesefassungmitFehlerkorrekturenStand12.12.2023_20240402_20231212.docx', + '55007': 'UTILMDAHBStrom-informatorischeLesefassung1.1KonsolidierteLesefassungmitFehlerkorrekturenStand12.12.2023_20240402_20231212.docx', + '55008': 'UTILMDAHBStrom-informatorischeLesefassung1.1KonsolidierteLesefassungmitFehlerkorrekturenStand12.12.2023_20240402_20231212.docx', + '55009': 'UTILMDAHBStrom-informatorischeLesefassung1.1KonsolidierteLesefassungmitFehlerkorrekturenStand12.12.2023_20240402_20231212.docx', + '55010': 'UTILMDAHBStrom-informatorischeLesefassung1.1KonsolidierteLesefassungmitFehlerkorrekturenStand12.12.2023_20240402_20231212.docx', + '55011': 'UTILMDAHBStrom-informatorischeLesefassung1.1KonsolidierteLesefassungmitFehlerkorrekturenStand12.12.2023_20240402_20231212.docx', + '55012': 'UTILMDAHBStrom-informatorischeLesefassung1.1KonsolidierteLesefassungmitFehlerkorrekturenStand12.12.2023_20240402_20231212.docx', + '55013': 'UTILMDAHBStrom-informatorischeLesefassung1.1KonsolidierteLesefassungmitFehlerkorrekturenStand12.12.2023_20240402_20231212.docx', + '55014': 'UTILMDAHBStrom-informatorischeLesefassung1.1KonsolidierteLesefassungmitFehlerkorrekturenStand12.12.2023_20240402_20231212.docx', + '55015': 'UTILMDAHBStrom-informatorischeLesefassung1.1KonsolidierteLesefassungmitFehlerkorrekturenStand12.12.2023_20240402_20231212.docx', + '55016': 'UTILMDAHBStrom-informatorischeLesefassung1.1KonsolidierteLesefassungmitFehlerkorrekturenStand12.12.2023_20240402_20231212.docx', + '55017': 'UTILMDAHBStrom-informatorischeLesefassung1.1KonsolidierteLesefassungmitFehlerkorrekturenStand12.12.2023_20240402_20231212.docx', + '55018': 'UTILMDAHBStrom-informatorischeLesefassung1.1KonsolidierteLesefassungmitFehlerkorrekturenStand12.12.2023_20240402_20231212.docx', + '55022': 'UTILMDAHBStrom-informatorischeLesefassung1.1KonsolidierteLesefassungmitFehlerkorrekturenStand12.12.2023_20240402_20231212.docx', + '55023': 'UTILMDAHBStrom-informatorischeLesefassung1.1KonsolidierteLesefassungmitFehlerkorrekturenStand12.12.2023_20240402_20231212.docx', + '55024': 'UTILMDAHBStrom-informatorischeLesefassung1.1KonsolidierteLesefassungmitFehlerkorrekturenStand12.12.2023_20240402_20231212.docx', + '55035': 'UTILMDAHBStrom-informatorischeLesefassung1.1KonsolidierteLesefassungmitFehlerkorrekturenStand12.12.2023_20240402_20231212.docx', + '55036': 'UTILMDAHBStrom-informatorischeLesefassung1.1KonsolidierteLesefassungmitFehlerkorrekturenStand12.12.2023_20240402_20231212.docx', + '55037': 'UTILMDAHBStrom-informatorischeLesefassung1.1KonsolidierteLesefassungmitFehlerkorrekturenStand12.12.2023_20240402_20231212.docx', + '55038': 'UTILMDAHBStrom-informatorischeLesefassung1.1KonsolidierteLesefassungmitFehlerkorrekturenStand12.12.2023_20240402_20231212.docx', + '55039': 'UTILMDAHBStrom-informatorischeLesefassung1.1KonsolidierteLesefassungmitFehlerkorrekturenStand12.12.2023_20240402_20231212.docx', + '55040': 'UTILMDAHBStrom-informatorischeLesefassung1.1KonsolidierteLesefassungmitFehlerkorrekturenStand12.12.2023_20240402_20231212.docx', + '55041': 'UTILMDAHBStrom-informatorischeLesefassung1.1KonsolidierteLesefassungmitFehlerkorrekturenStand12.12.2023_20240402_20231212.docx', + '55042': 'UTILMDAHBStrom-informatorischeLesefassung1.1KonsolidierteLesefassungmitFehlerkorrekturenStand12.12.2023_20240402_20231212.docx', + '55043': 'UTILMDAHBStrom-informatorischeLesefassung1.1KonsolidierteLesefassungmitFehlerkorrekturenStand12.12.2023_20240402_20231212.docx', + '55044': 'UTILMDAHBStrom-informatorischeLesefassung1.1KonsolidierteLesefassungmitFehlerkorrekturenStand12.12.2023_20240402_20231212.docx', + '55051': 'UTILMDAHBStrom-informatorischeLesefassung1.1KonsolidierteLesefassungmitFehlerkorrekturenStand12.12.2023_20240402_20231212.docx', + '55052': 'UTILMDAHBStrom-informatorischeLesefassung1.1KonsolidierteLesefassungmitFehlerkorrekturenStand12.12.2023_20240402_20231212.docx', + '55053': 'UTILMDAHBStrom-informatorischeLesefassung1.1KonsolidierteLesefassungmitFehlerkorrekturenStand12.12.2023_20240402_20231212.docx', + '55060': 'UTILMDAHBStrom-informatorischeLesefassung1.1KonsolidierteLesefassungmitFehlerkorrekturenStand12.12.2023_20240402_20231212.docx', + '55062': 'UTILMDAHBMaBiS-informatorischeLesefassung4.1KonsolidierteLesefassungmitFehlerkorrekturenStand12.12.2023_20240402_20231212.docx', + '55063': 'UTILMDAHBMaBiS-informatorischeLesefassung4.1KonsolidierteLesefassungmitFehlerkorrekturenStand12.12.2023_20240402_20231212.docx', + '55064': 'UTILMDAHBMaBiS-informatorischeLesefassung4.1KonsolidierteLesefassungmitFehlerkorrekturenStand12.12.2023_20240402_20231212.docx', + '55065': 'UTILMDAHBMaBiS-informatorischeLesefassung4.1KonsolidierteLesefassungmitFehlerkorrekturenStand12.12.2023_20240402_20231212.docx', + '55066': 'UTILMDAHBMaBiS-informatorischeLesefassung4.1KonsolidierteLesefassungmitFehlerkorrekturenStand12.12.2023_20240402_20231212.docx', + '55067': 'UTILMDAHBMaBiS-informatorischeLesefassung4.1KonsolidierteLesefassungmitFehlerkorrekturenStand12.12.2023_20240402_20231212.docx', + '55069': 'UTILMDAHBMaBiS-informatorischeLesefassung4.1KonsolidierteLesefassungmitFehlerkorrekturenStand12.12.2023_20240402_20231212.docx', + '55070': 'UTILMDAHBMaBiS-informatorischeLesefassung4.1KonsolidierteLesefassungmitFehlerkorrekturenStand12.12.2023_20240402_20231212.docx', + '55071': 'UTILMDAHBMaBiS-informatorischeLesefassung4.1KonsolidierteLesefassungmitFehlerkorrekturenStand12.12.2023_20240402_20231212.docx', + '55072': 'UTILMDAHBMaBiS-informatorischeLesefassung4.1KonsolidierteLesefassungmitFehlerkorrekturenStand12.12.2023_20240402_20231212.docx', + '55073': 'UTILMDAHBMaBiS-informatorischeLesefassung4.1KonsolidierteLesefassungmitFehlerkorrekturenStand12.12.2023_20240402_20231212.docx', + '55074': 'HerkunftsnachweisregisterAHB-informatorischeLesefassung2.3cKonsolidierteLesefassungmitFehlerkorrekturenStand19.06.2023_20240402_20231001.docx', + '55075': 'HerkunftsnachweisregisterAHB-informatorischeLesefassung2.3cKonsolidierteLesefassungmitFehlerkorrekturenStand19.06.2023_20240402_20231001.docx', + '55076': 'HerkunftsnachweisregisterAHB-informatorischeLesefassung2.3cKonsolidierteLesefassungmitFehlerkorrekturenStand19.06.2023_20240402_20231001.docx', + '55077': 'UTILMDAHBStrom-informatorischeLesefassung1.1KonsolidierteLesefassungmitFehlerkorrekturenStand12.12.2023_20240402_20231212.docx', + '55078': 'UTILMDAHBStrom-informatorischeLesefassung1.1KonsolidierteLesefassungmitFehlerkorrekturenStand12.12.2023_20240402_20231212.docx', + '55079': 'UTILMDAHBStrom-informatorischeLesefassung1.1KonsolidierteLesefassungmitFehlerkorrekturenStand12.12.2023_20240402_20231212.docx', + '55080': 'UTILMDAHBStrom-informatorischeLesefassung1.1KonsolidierteLesefassungmitFehlerkorrekturenStand12.12.2023_20240402_20231212.docx', + '55081': 'UTILMDAHBStrom-informatorischeLesefassung1.1KonsolidierteLesefassungmitFehlerkorrekturenStand12.12.2023_20240402_20231212.docx', + '55082': 'UTILMDAHBStrom-informatorischeLesefassung1.1KonsolidierteLesefassungmitFehlerkorrekturenStand12.12.2023_20240402_20231212.docx', + '55083': 'UTILMDAHBStrom-informatorischeLesefassung1.1KonsolidierteLesefassungmitFehlerkorrekturenStand12.12.2023_20240402_20231212.docx', + '55084': 'UTILMDAHBStrom-informatorischeLesefassung1.1KonsolidierteLesefassungmitFehlerkorrekturenStand12.12.2023_20240402_20231212.docx', + '55085': 'UTILMDAHBStrom-informatorischeLesefassung1.1KonsolidierteLesefassungmitFehlerkorrekturenStand12.12.2023_20240402_20231212.docx', + '55086': 'UTILMDAHBStrom-informatorischeLesefassung1.1KonsolidierteLesefassungmitFehlerkorrekturenStand12.12.2023_20240402_20231212.docx', + '55087': 'UTILMDAHBStrom-informatorischeLesefassung1.1KonsolidierteLesefassungmitFehlerkorrekturenStand12.12.2023_20240402_20231212.docx', + '55088': 'UTILMDAHBStrom-informatorischeLesefassung1.1KonsolidierteLesefassungmitFehlerkorrekturenStand12.12.2023_20240402_20231212.docx', + '55089': 'UTILMDAHBStrom-informatorischeLesefassung1.1KonsolidierteLesefassungmitFehlerkorrekturenStand12.12.2023_20240402_20231212.docx', + '55090': 'UTILMDAHBStrom-informatorischeLesefassung1.1KonsolidierteLesefassungmitFehlerkorrekturenStand12.12.2023_20240402_20231212.docx', + '55091': 'UTILMDAHBStrom-informatorischeLesefassung1.1KonsolidierteLesefassungmitFehlerkorrekturenStand12.12.2023_20240402_20231212.docx', + '55092': 'UTILMDAHBStrom-informatorischeLesefassung1.1KonsolidierteLesefassungmitFehlerkorrekturenStand12.12.2023_20240402_20231212.docx', + '55093': 'UTILMDAHBStrom-informatorischeLesefassung1.1KonsolidierteLesefassungmitFehlerkorrekturenStand12.12.2023_20240402_20231212.docx', + '55094': 'UTILMDAHBStrom-informatorischeLesefassung1.1KonsolidierteLesefassungmitFehlerkorrekturenStand12.12.2023_20240402_20231212.docx', + '55095': 'UTILMDAHBStrom-informatorischeLesefassung1.1KonsolidierteLesefassungmitFehlerkorrekturenStand12.12.2023_20240402_20231212.docx', + '55101': 'UTILMDAHBStrom-informatorischeLesefassung1.1KonsolidierteLesefassungmitFehlerkorrekturenStand12.12.2023_20240402_20231212.docx', + '55102': 'UTILMDAHBStrom-informatorischeLesefassung1.1KonsolidierteLesefassungmitFehlerkorrekturenStand12.12.2023_20240402_20231212.docx', + '55103': 'UTILMDAHBStrom-informatorischeLesefassung1.1KonsolidierteLesefassungmitFehlerkorrekturenStand12.12.2023_20240402_20231212.docx', + '55104': 'UTILMDAHBStrom-informatorischeLesefassung1.1KonsolidierteLesefassungmitFehlerkorrekturenStand12.12.2023_20240402_20231212.docx', + '55105': 'UTILMDAHBStrom-informatorischeLesefassung1.1KonsolidierteLesefassungmitFehlerkorrekturenStand12.12.2023_20240402_20231212.docx', + '55106': 'UTILMDAHBStrom-informatorischeLesefassung1.1KonsolidierteLesefassungmitFehlerkorrekturenStand12.12.2023_20240402_20231212.docx', + '55107': 'UTILMDAHBStrom-informatorischeLesefassung1.1KonsolidierteLesefassungmitFehlerkorrekturenStand12.12.2023_20240402_20231212.docx', + '55108': 'UTILMDAHBStrom-informatorischeLesefassung1.1KonsolidierteLesefassungmitFehlerkorrekturenStand12.12.2023_20240402_20231212.docx', + '55109': 'UTILMDAHBStrom-informatorischeLesefassung1.1KonsolidierteLesefassungmitFehlerkorrekturenStand12.12.2023_20240402_20231212.docx', + '55110': 'UTILMDAHBStrom-informatorischeLesefassung1.1KonsolidierteLesefassungmitFehlerkorrekturenStand12.12.2023_20240402_20231212.docx', + '55111': 'UTILMDAHBStrom-informatorischeLesefassung1.1KonsolidierteLesefassungmitFehlerkorrekturenStand12.12.2023_20240402_20231212.docx', + '55112': 'UTILMDAHBStrom-informatorischeLesefassung1.1KonsolidierteLesefassungmitFehlerkorrekturenStand12.12.2023_20240402_20231212.docx', + '55113': 'UTILMDAHBStrom-informatorischeLesefassung1.1KonsolidierteLesefassungmitFehlerkorrekturenStand12.12.2023_20240402_20231212.docx', + '55115': 'UTILMDAHBStrom-informatorischeLesefassung1.1KonsolidierteLesefassungmitFehlerkorrekturenStand12.12.2023_20240402_20231212.docx', + '55116': 'UTILMDAHBStrom-informatorischeLesefassung1.1KonsolidierteLesefassungmitFehlerkorrekturenStand12.12.2023_20240402_20231212.docx', + '55117': 'UTILMDAHBStrom-informatorischeLesefassung1.1KonsolidierteLesefassungmitFehlerkorrekturenStand12.12.2023_20240402_20231212.docx', + '55119': 'UTILMDAHBStrom-informatorischeLesefassung1.1KonsolidierteLesefassungmitFehlerkorrekturenStand12.12.2023_20240402_20231212.docx', + '55120': 'UTILMDAHBStrom-informatorischeLesefassung1.1KonsolidierteLesefassungmitFehlerkorrekturenStand12.12.2023_20240402_20231212.docx', + '55121': 'UTILMDAHBStrom-informatorischeLesefassung1.1KonsolidierteLesefassungmitFehlerkorrekturenStand12.12.2023_20240402_20231212.docx', + '55123': 'UTILMDAHBStrom-informatorischeLesefassung1.1KonsolidierteLesefassungmitFehlerkorrekturenStand12.12.2023_20240402_20231212.docx', + '55124': 'UTILMDAHBStrom-informatorischeLesefassung1.1KonsolidierteLesefassungmitFehlerkorrekturenStand12.12.2023_20240402_20231212.docx', + '55126': 'UTILMDAHBStrom-informatorischeLesefassung1.1KonsolidierteLesefassungmitFehlerkorrekturenStand12.12.2023_20240402_20231212.docx', + '55127': 'UTILMDAHBStrom-informatorischeLesefassung1.1KonsolidierteLesefassungmitFehlerkorrekturenStand12.12.2023_20240402_20231212.docx', + '55133': 'UTILMDAHBStrom-informatorischeLesefassung1.1KonsolidierteLesefassungmitFehlerkorrekturenStand12.12.2023_20240402_20231212.docx', + '55134': 'UTILMDAHBStrom-informatorischeLesefassung1.1KonsolidierteLesefassungmitFehlerkorrekturenStand12.12.2023_20240402_20231212.docx', + '55135': 'UTILMDAHBStrom-informatorischeLesefassung1.1KonsolidierteLesefassungmitFehlerkorrekturenStand12.12.2023_20240402_20231212.docx', + '55136': 'UTILMDAHBStrom-informatorischeLesefassung1.1KonsolidierteLesefassungmitFehlerkorrekturenStand12.12.2023_20240402_20231212.docx', + '55137': 'UTILMDAHBStrom-informatorischeLesefassung1.1KonsolidierteLesefassungmitFehlerkorrekturenStand12.12.2023_20240402_20231212.docx', + '55138': 'UTILMDAHBStrom-informatorischeLesefassung1.1KonsolidierteLesefassungmitFehlerkorrekturenStand12.12.2023_20240402_20231212.docx', + '55139': 'UTILMDAHBStrom-informatorischeLesefassung1.1KonsolidierteLesefassungmitFehlerkorrekturenStand12.12.2023_20240402_20231212.docx', + '55140': 'UTILMDAHBStrom-informatorischeLesefassung1.1KonsolidierteLesefassungmitFehlerkorrekturenStand12.12.2023_20240402_20231212.docx', + '55142': 'UTILMDAHBStrom-informatorischeLesefassung1.1KonsolidierteLesefassungmitFehlerkorrekturenStand12.12.2023_20240402_20231212.docx', + '55143': 'UTILMDAHBStrom-informatorischeLesefassung1.1KonsolidierteLesefassungmitFehlerkorrekturenStand12.12.2023_20240402_20231212.docx', + '55145': 'UTILMDAHBStrom-informatorischeLesefassung1.1KonsolidierteLesefassungmitFehlerkorrekturenStand12.12.2023_20240402_20231212.docx', + '55146': 'UTILMDAHBStrom-informatorischeLesefassung1.1KonsolidierteLesefassungmitFehlerkorrekturenStand12.12.2023_20240402_20231212.docx', + '55147': 'UTILMDAHBStrom-informatorischeLesefassung1.1KonsolidierteLesefassungmitFehlerkorrekturenStand12.12.2023_20240402_20231212.docx', + '55148': 'UTILMDAHBStrom-informatorischeLesefassung1.1KonsolidierteLesefassungmitFehlerkorrekturenStand12.12.2023_20240402_20231212.docx', + '55149': 'UTILMDAHBStrom-informatorischeLesefassung1.1KonsolidierteLesefassungmitFehlerkorrekturenStand12.12.2023_20240402_20231212.docx', + '55150': 'UTILMDAHBStrom-informatorischeLesefassung1.1KonsolidierteLesefassungmitFehlerkorrekturenStand12.12.2023_20240402_20231212.docx', + '55151': 'UTILMDAHBStrom-informatorischeLesefassung1.1KonsolidierteLesefassungmitFehlerkorrekturenStand12.12.2023_20240402_20231212.docx', + '55152': 'UTILMDAHBStrom-informatorischeLesefassung1.1KonsolidierteLesefassungmitFehlerkorrekturenStand12.12.2023_20240402_20231212.docx', + '55153': 'UTILMDAHBStrom-informatorischeLesefassung1.1KonsolidierteLesefassungmitFehlerkorrekturenStand12.12.2023_20240402_20231212.docx', + '55154': 'UTILMDAHBStrom-informatorischeLesefassung1.1KonsolidierteLesefassungmitFehlerkorrekturenStand12.12.2023_20240402_20231212.docx', + '55155': 'UTILMDAHBStrom-informatorischeLesefassung1.1KonsolidierteLesefassungmitFehlerkorrekturenStand12.12.2023_20240402_20231212.docx', + '55156': 'UTILMDAHBStrom-informatorischeLesefassung1.1KonsolidierteLesefassungmitFehlerkorrekturenStand12.12.2023_20240402_20231212.docx', + '55157': 'UTILMDAHBStrom-informatorischeLesefassung1.1KonsolidierteLesefassungmitFehlerkorrekturenStand12.12.2023_20240402_20231212.docx', + '55159': 'UTILMDAHBStrom-informatorischeLesefassung1.1KonsolidierteLesefassungmitFehlerkorrekturenStand12.12.2023_20240402_20231212.docx', + '55160': 'UTILMDAHBStrom-informatorischeLesefassung1.1KonsolidierteLesefassungmitFehlerkorrekturenStand12.12.2023_20240402_20231212.docx', + '55161': 'UTILMDAHBStrom-informatorischeLesefassung1.1KonsolidierteLesefassungmitFehlerkorrekturenStand12.12.2023_20240402_20231212.docx', + '55162': 'UTILMDAHBStrom-informatorischeLesefassung1.1KonsolidierteLesefassungmitFehlerkorrekturenStand12.12.2023_20240402_20231212.docx', + '55163': 'UTILMDAHBStrom-informatorischeLesefassung1.1KonsolidierteLesefassungmitFehlerkorrekturenStand12.12.2023_20240402_20231212.docx', + '55164': 'UTILMDAHBStrom-informatorischeLesefassung1.1KonsolidierteLesefassungmitFehlerkorrekturenStand12.12.2023_20240402_20231212.docx', + '55165': 'UTILMDAHBStrom-informatorischeLesefassung1.1KonsolidierteLesefassungmitFehlerkorrekturenStand12.12.2023_20240402_20231212.docx', + '55166': 'UTILMDAHBStrom-informatorischeLesefassung1.1KonsolidierteLesefassungmitFehlerkorrekturenStand12.12.2023_20240402_20231212.docx', + '55167': 'UTILMDAHBStrom-informatorischeLesefassung1.1KonsolidierteLesefassungmitFehlerkorrekturenStand12.12.2023_20240402_20231212.docx', + '55168': 'UTILMDAHBStrom-informatorischeLesefassung1.1KonsolidierteLesefassungmitFehlerkorrekturenStand12.12.2023_20240402_20231212.docx', + '55169': 'UTILMDAHBStrom-informatorischeLesefassung1.1KonsolidierteLesefassungmitFehlerkorrekturenStand12.12.2023_20240402_20231212.docx', + '55170': 'UTILMDAHBStrom-informatorischeLesefassung1.1KonsolidierteLesefassungmitFehlerkorrekturenStand12.12.2023_20240402_20231212.docx', + '55171': 'UTILMDAHBStrom-informatorischeLesefassung1.1KonsolidierteLesefassungmitFehlerkorrekturenStand12.12.2023_20240402_20231212.docx', + '55172': 'UTILMDAHBStrom-informatorischeLesefassung1.1KonsolidierteLesefassungmitFehlerkorrekturenStand12.12.2023_20240402_20231212.docx', + '55173': 'UTILMDAHBStrom-informatorischeLesefassung1.1KonsolidierteLesefassungmitFehlerkorrekturenStand12.12.2023_20240402_20231212.docx', + '55174': 'UTILMDAHBStrom-informatorischeLesefassung1.1KonsolidierteLesefassungmitFehlerkorrekturenStand12.12.2023_20240402_20231212.docx', + '55175': 'UTILMDAHBStrom-informatorischeLesefassung1.1KonsolidierteLesefassungmitFehlerkorrekturenStand12.12.2023_20240402_20231212.docx', + '55176': 'UTILMDAHBStrom-informatorischeLesefassung1.1KonsolidierteLesefassungmitFehlerkorrekturenStand12.12.2023_20240402_20231212.docx', + '55177': 'UTILMDAHBStrom-informatorischeLesefassung1.1KonsolidierteLesefassungmitFehlerkorrekturenStand12.12.2023_20240402_20231212.docx', + '55178': 'UTILMDAHBStrom-informatorischeLesefassung1.1KonsolidierteLesefassungmitFehlerkorrekturenStand12.12.2023_20240402_20231212.docx', + '55180': 'UTILMDAHBStrom-informatorischeLesefassung1.1KonsolidierteLesefassungmitFehlerkorrekturenStand12.12.2023_20240402_20231212.docx', + '55181': 'UTILMDAHBStrom-informatorischeLesefassung1.1KonsolidierteLesefassungmitFehlerkorrekturenStand12.12.2023_20240402_20231212.docx', + '55182': 'UTILMDAHBStrom-informatorischeLesefassung1.1KonsolidierteLesefassungmitFehlerkorrekturenStand12.12.2023_20240402_20231212.docx', + '55185': 'UTILMDAHBStrom-informatorischeLesefassung1.1KonsolidierteLesefassungmitFehlerkorrekturenStand12.12.2023_20240402_20231212.docx', + '55186': 'UTILMDAHBStrom-informatorischeLesefassung1.1KonsolidierteLesefassungmitFehlerkorrekturenStand12.12.2023_20240402_20231212.docx', + '55187': 'UTILMDAHBStrom-informatorischeLesefassung1.1KonsolidierteLesefassungmitFehlerkorrekturenStand12.12.2023_20240402_20231212.docx', + '55188': 'UTILMDAHBStrom-informatorischeLesefassung1.1KonsolidierteLesefassungmitFehlerkorrekturenStand12.12.2023_20240402_20231212.docx', + '55189': 'UTILMDAHBStrom-informatorischeLesefassung1.1KonsolidierteLesefassungmitFehlerkorrekturenStand12.12.2023_20240402_20231212.docx', + '55190': 'UTILMDAHBStrom-informatorischeLesefassung1.1KonsolidierteLesefassungmitFehlerkorrekturenStand12.12.2023_20240402_20231212.docx', + '55191': 'UTILMDAHBStrom-informatorischeLesefassung1.1KonsolidierteLesefassungmitFehlerkorrekturenStand12.12.2023_20240402_20231212.docx', + '55192': 'UTILMDAHBStrom-informatorischeLesefassung1.1KonsolidierteLesefassungmitFehlerkorrekturenStand12.12.2023_20240402_20231212.docx', + '55193': 'UTILMDAHBStrom-informatorischeLesefassung1.1KonsolidierteLesefassungmitFehlerkorrekturenStand12.12.2023_20240402_20231212.docx', + '55194': 'UTILMDAHBStrom-informatorischeLesefassung1.1KonsolidierteLesefassungmitFehlerkorrekturenStand12.12.2023_20240402_20231212.docx', + '55195': 'UTILMDAHBMaBiS-informatorischeLesefassung4.1KonsolidierteLesefassungmitFehlerkorrekturenStand12.12.2023_20240402_20231212.docx', + '55196': 'UTILMDAHBMaBiS-informatorischeLesefassung4.1KonsolidierteLesefassungmitFehlerkorrekturenStand12.12.2023_20240402_20231212.docx', + '55197': 'UTILMDAHBMaBiS-informatorischeLesefassung4.1KonsolidierteLesefassungmitFehlerkorrekturenStand12.12.2023_20240402_20231212.docx', + '55198': 'UTILMDAHBMaBiS-informatorischeLesefassung4.1KonsolidierteLesefassungmitFehlerkorrekturenStand12.12.2023_20240402_20231212.docx', + '55199': 'UTILMDAHBMaBiS-informatorischeLesefassung4.1KonsolidierteLesefassungmitFehlerkorrekturenStand12.12.2023_20240402_20231212.docx', + '55200': 'UTILMDAHBMaBiS-informatorischeLesefassung4.1KonsolidierteLesefassungmitFehlerkorrekturenStand12.12.2023_20240402_20231212.docx', + '55201': 'UTILMDAHBMaBiS-informatorischeLesefassung4.1KonsolidierteLesefassungmitFehlerkorrekturenStand12.12.2023_20240402_20231212.docx', + '55202': 'UTILMDAHBMaBiS-informatorischeLesefassung4.1KonsolidierteLesefassungmitFehlerkorrekturenStand12.12.2023_20240402_20231212.docx', + '55203': 'UTILMDAHBMaBiS-informatorischeLesefassung4.1KonsolidierteLesefassungmitFehlerkorrekturenStand12.12.2023_20240402_20231212.docx', + '55204': 'UTILMDAHBMaBiS-informatorischeLesefassung4.1KonsolidierteLesefassungmitFehlerkorrekturenStand12.12.2023_20240402_20231212.docx', + '55205': 'UTILMDAHBMaBiS-informatorischeLesefassung4.1KonsolidierteLesefassungmitFehlerkorrekturenStand12.12.2023_20240402_20231212.docx', + '55206': 'UTILMDAHBMaBiS-informatorischeLesefassung4.1KonsolidierteLesefassungmitFehlerkorrekturenStand12.12.2023_20240402_20231212.docx', + '55207': 'UTILMDAHBMaBiS-informatorischeLesefassung4.1KonsolidierteLesefassungmitFehlerkorrekturenStand12.12.2023_20240402_20231212.docx', + '55208': 'UTILMDAHBMaBiS-informatorischeLesefassung4.1KonsolidierteLesefassungmitFehlerkorrekturenStand12.12.2023_20240402_20231212.docx', + '55209': 'UTILMDAHBMaBiS-informatorischeLesefassung4.1KonsolidierteLesefassungmitFehlerkorrekturenStand12.12.2023_20240402_20231212.docx', + '55210': 'UTILMDAHBMaBiS-informatorischeLesefassung4.1KonsolidierteLesefassungmitFehlerkorrekturenStand12.12.2023_20240402_20231212.docx', + '55211': 'UTILMDAHBMaBiS-informatorischeLesefassung4.1KonsolidierteLesefassungmitFehlerkorrekturenStand12.12.2023_20240402_20231212.docx', + '55212': 'UTILMDAHBMaBiS-informatorischeLesefassung4.1KonsolidierteLesefassungmitFehlerkorrekturenStand12.12.2023_20240402_20231212.docx', + '55213': 'UTILMDAHBMaBiS-informatorischeLesefassung4.1KonsolidierteLesefassungmitFehlerkorrekturenStand12.12.2023_20240402_20231212.docx', + '55214': 'UTILMDAHBMaBiS-informatorischeLesefassung4.1KonsolidierteLesefassungmitFehlerkorrekturenStand12.12.2023_20240402_20231212.docx', + '55215': 'UTILMDAHBStrom-informatorischeLesefassung1.1KonsolidierteLesefassungmitFehlerkorrekturenStand12.12.2023_20240402_20231212.docx', + '55218': 'UTILMDAHBStrom-informatorischeLesefassung1.1KonsolidierteLesefassungmitFehlerkorrekturenStand12.12.2023_20240402_20231212.docx', + '55219': 'UTILMDAHBStrom-informatorischeLesefassung1.1KonsolidierteLesefassungmitFehlerkorrekturenStand12.12.2023_20240402_20231212.docx', + '55220': 'UTILMDAHBStrom-informatorischeLesefassung1.1KonsolidierteLesefassungmitFehlerkorrekturenStand12.12.2023_20240402_20231212.docx', + '55221': 'UTILMDAHBStrom-informatorischeLesefassung1.1KonsolidierteLesefassungmitFehlerkorrekturenStand12.12.2023_20240402_20231212.docx', + '55222': 'UTILMDAHBStrom-informatorischeLesefassung1.1KonsolidierteLesefassungmitFehlerkorrekturenStand12.12.2023_20240402_20231212.docx', + '55223': 'UTILMDAHBMaBiS-informatorischeLesefassung4.1KonsolidierteLesefassungmitFehlerkorrekturenStand12.12.2023_20240402_20231212.docx', + '55224': 'UTILMDAHBMaBiS-informatorischeLesefassung4.1KonsolidierteLesefassungmitFehlerkorrekturenStand12.12.2023_20240402_20231212.docx', + '55225': 'UTILMDAHBStrom-informatorischeLesefassung1.1KonsolidierteLesefassungmitFehlerkorrekturenStand12.12.2023_20240402_20231212.docx', + '55226': 'UTILMDAHBStrom-informatorischeLesefassung1.1KonsolidierteLesefassungmitFehlerkorrekturenStand12.12.2023_20240402_20231212.docx', + '55227': 'UTILMDAHBStrom-informatorischeLesefassung1.1KonsolidierteLesefassungmitFehlerkorrekturenStand12.12.2023_20240402_20231212.docx', + '55228': 'UTILMDAHBStrom-informatorischeLesefassung1.1KonsolidierteLesefassungmitFehlerkorrekturenStand12.12.2023_20240402_20231212.docx', + '55229': 'UTILMDAHBStrom-informatorischeLesefassung1.1KonsolidierteLesefassungmitFehlerkorrekturenStand12.12.2023_20240402_20231212.docx', + '55230': 'UTILMDAHBStrom-informatorischeLesefassung1.1KonsolidierteLesefassungmitFehlerkorrekturenStand12.12.2023_20240402_20231212.docx', + '55231': 'UTILMDAHBStrom-informatorischeLesefassung1.1KonsolidierteLesefassungmitFehlerkorrekturenStand12.12.2023_20240402_20231212.docx', + '55232': 'UTILMDAHBStrom-informatorischeLesefassung1.1KonsolidierteLesefassungmitFehlerkorrekturenStand12.12.2023_20240402_20231212.docx', + '55233': 'UTILMDAHBStrom-informatorischeLesefassung1.1KonsolidierteLesefassungmitFehlerkorrekturenStand12.12.2023_20240402_20231212.docx', + '55234': 'UTILMDAHBStrom-informatorischeLesefassung1.1KonsolidierteLesefassungmitFehlerkorrekturenStand12.12.2023_20240402_20231212.docx', + '55235': 'UTILMDAHBMaBiS-informatorischeLesefassung4.1KonsolidierteLesefassungmitFehlerkorrekturenStand12.12.2023_20240402_20231212.docx', + '55236': 'UTILMDAHBMaBiS-informatorischeLesefassung4.1KonsolidierteLesefassungmitFehlerkorrekturenStand12.12.2023_20240402_20231212.docx', + '55237': 'UTILMDAHBMaBiS-informatorischeLesefassung4.1KonsolidierteLesefassungmitFehlerkorrekturenStand12.12.2023_20240402_20231212.docx', + '55238': 'UTILMDAHBStrom-informatorischeLesefassung1.1KonsolidierteLesefassungmitFehlerkorrekturenStand12.12.2023_20240402_20231212.docx', + '55239': 'UTILMDAHBStrom-informatorischeLesefassung1.1KonsolidierteLesefassungmitFehlerkorrekturenStand12.12.2023_20240402_20231212.docx', + '55240': 'UTILMDAHBStrom-informatorischeLesefassung1.1KonsolidierteLesefassungmitFehlerkorrekturenStand12.12.2023_20240402_20231212.docx', + '55241': 'UTILMDAHBStrom-informatorischeLesefassung1.1KonsolidierteLesefassungmitFehlerkorrekturenStand12.12.2023_20240402_20231212.docx', + '55242': 'UTILMDAHBStrom-informatorischeLesefassung1.1KonsolidierteLesefassungmitFehlerkorrekturenStand12.12.2023_20240402_20231212.docx', + '55243': 'UTILMDAHBStrom-informatorischeLesefassung1.1KonsolidierteLesefassungmitFehlerkorrekturenStand12.12.2023_20240402_20231212.docx', + '55553': 'UTILMDAHBStrom-informatorischeLesefassung1.1KonsolidierteLesefassungmitFehlerkorrekturenStand12.12.2023_20240402_20231212.docx', + '55554': 'UTILMDAHBStrom-informatorischeLesefassung1.1KonsolidierteLesefassungmitFehlerkorrekturenStand12.12.2023_20240402_20231212.docx', + '55555': 'UTILMDAHBStrom-informatorischeLesefassung1.1KonsolidierteLesefassungmitFehlerkorrekturenStand12.12.2023_20240402_20231212.docx', + '55556': 'UTILMDAHBStrom-informatorischeLesefassung1.1KonsolidierteLesefassungmitFehlerkorrekturenStand12.12.2023_20240402_20231212.docx', + }) +# --- diff --git a/unittests/__snapshots__/test_current_state.ambr b/unittests/__snapshots__/test_current_state.ambr index aec40d11..a159ae7b 100644 --- a/unittests/__snapshots__/test_current_state.ambr +++ b/unittests/__snapshots__/test_current_state.ambr @@ -1,3502 +1,16875 @@ # serializer version: 1 -# name: TestCli.test_kohlrahbi_cli_with_valid_arguments[proof of concept] - dict({ - '17201.csv': ''' - ,Segmentname,Segmentgruppe,Segment,Datenelement,Segment ID,Code,Qualifier,Beschreibung,Bedingungsausdruck,Bedingung - 0,Nachrichten-Kopfsegment,,UNH,,00001,,,,Muss, - 1,Nachrichten-Kopfsegment,,UNH,0062,00001,,,Nachrichten-Referenznummer,X, - 2,Nachrichten-Kopfsegment,,UNH,0065,00001,ORDERS,,Bestellung,X, - 3,Nachrichten-Kopfsegment,,UNH,0052,00001,D,,Entwurfs-Version,X, - 4,Nachrichten-Kopfsegment,,UNH,0054,00001,09B,,Ausgabe 2009 - B,X, - 5,Nachrichten-Kopfsegment,,UNH,0051,00001,UN,,UN/CEFACT,X, - 6,Nachrichten-Kopfsegment,,UNH,0057,00001,1.3,,VersionsnummerderzugrundeliegendenBDEW-Nachrichtenbeschreibung,X, - 7,Beginn der Nachricht,,BGM,,00002,,,,Muss, - 8,Beginn der Nachricht,,BGM,1001,00002,E40,,Bilanzkreiszuordnungsliste,, - 9,Beginn der Nachricht,,BGM,1001,,Z05,,Clearingliste,, - 10,Beginn der Nachricht,,BGM,1001,,Z19,,normiertes Profil/Profilschar,X, - 11,Beginn der Nachricht,,BGM,1004,00002,,,Dokumentennummer,X, - 12,Nachrichtendatum,,DTM,,00003,,,,Muss, - 13,Nachrichtendatum,,DTM,2005,00003,137,,Dokumenten-/Nachrichtendatum/-zeit,X, - 14,Nachrichtendatum,,DTM,2380,00003,,,"Datum oder Uhrzeit oderZeitspanne, Wert",X [931][494],"[494] Das hier genannte Datum muss der Zeitpunkt sein, zu dem das Dokument erstellt wurde, oder ein Zeitpunkt, der davor liegt. - [931] Format: ZZZ = +00" - 15,Nachrichtendatum,,DTM,2379,00003,303,,CCYYMMDDHHMMZZZ,X, - 16,Ausführungsdatum,,DTM,,00004,,,,,"[33] Wenn IMD+Z01 vorhanden - [34] Wenn IMD+Z02 vorhanden" - 17,Ausführungsdatum,,DTM,2005,00004,203,,Ausführungsdatum/-zeit,, - 18,Ausführungsdatum,,DTM,2380,00004,,,Datum oder Uhrzeit oder,, - 19,Ausführungsdatum,,DTM,2379,00004,303,,CCYYMMDDHHMMZZZ,, - 20,Betrachtungszeitintervall,,DTM,,00006,,,,,[1] Wenn IMD+Z03 vorhanden - 21,Betrachtungszeitintervall,,DTM,2005,00006,273,,Gültigkeitszeitspanne,, - 22,Betrachtungszeitintervall,,DTM,2380,00006,,,"Datum oder Uhrzeit oderZeitspanne, Wert",, - 23,Betrachtungszeitintervall,,DTM,2379,00006,610,,CCYYMM,, - 24,Abonnement,,IMD,,00008,,,,Muss, - 25,Abonnement,,IMD,7081,00008,Z01,,Start Abo,X, - 26,Abonnement,,IMD,7081,,Z02,,Ende Abo,X, - 27,Abonnement,,IMD,7081,,Z03,,ohne Abo,, - 28,Prüfidentifikator,SG1,,,,,,,Muss, - 29,Prüfidentifikator,SG1,RFF,,00019,,,,Muss, - 30,Prüfidentifikator,SG1,RFF,1153,00019,Z13,,Prüfidentifikator,X, - 31,Prüfidentifikator,SG1,RFF,1154,00019,17201,,AnforderungnormierterProfile/Profilscharen,X, - 32,Prüfidentifikator,SG1,RFF,1154,,17202,,AnforderungLieferantenclearingliste,, - 33,Prüfidentifikator,SG1,RFF,1154,,17203,,AnforderungBilanzkreiszuordnungsliste,, - 34,Prüfidentifikator,SG1,RFF,1154,,17204,,AnforderungClearingliste BAS,, - 35,Prüfidentifikator,SG1,RFF,1154,,17205,,AnforderungClearingliste DZR,, - 36,MP-ID Absender,SG2,,,,,,,Muss, - 37,MP-ID Absender,SG2,NAD,,00020,,,,Muss, - 38,MP-ID Absender,SG2,NAD,3035,00020,MS,,Dokumenten-/Nachrichtenaussteller bzw. -absender,X, - 39,MP-ID Absender,SG2,NAD,3039,00020,,,MP-ID,X [61],[61] MP-ID nur aus Sparte Strom - 40,MP-ID Absender,SG2,NAD,3055,00020,9,,GS1,X, - 41,MP-ID Absender,SG2,NAD,3055,,293,,"DE, BDEW(Bundesverbandder Energie- undWasserwirtschafte.V.)",X, - 42,Ansprechpartner,SG5,,,,,,,Kann, - 43,Ansprechpartner,SG5,CTA,,00021,,,,Muss, - 44,Ansprechpartner,SG5,CTA,3139,00021,IC,,Informationskontakt,X, - 45,Ansprechpartner,SG5,CTA,3412,00021,,,Kontakt,X, - 46,Kommunikationsverbindu ng,SG5,COM,,00022,,,,Muss, - 47,Kommunikationsverbindu ng,SG5,COM,3148,00022,,,"Kommunikationsadresse,Identifikation",X, - 48,Kommunikationsverbindu ng,SG5,COM,3155,00022,EM,,Elektronische Post,X [1P0..1], - 49,Kommunikationsverbindu ng,SG5,COM,3155,,FX,,Telefax,X [1P0..1], - 50,Kommunikationsverbindu ng,SG5,COM,3155,,TE,,Telefon,X [1P0..1], - 51,Kommunikationsverbindu ng,SG5,COM,3155,,AJ,,weiteres Telefon,X [1P0..1], - 52,Kommunikationsverbindu ng,SG5,COM,3155,,AL,,Handy,X [1P0..1], - 53,MP-ID Empfänger,SG2,,,,,,,Muss, - 54,MP-ID Empfänger,SG2,NAD,,00023,,,,Muss, - 55,MP-ID Empfänger,SG2,NAD,3035,00023,MR,,Nachrichtenempfänger,X, - 56,MP-ID Empfänger,SG2,NAD,3039,00023,,,MP-ID,X [61],[61] MP-ID nur aus Sparte Strom - 57,MP-ID Empfänger,SG2,NAD,3055,00023,9,,GS1,X, - 58,MP-ID Empfänger,SG2,NAD,3055,,293,,"DE, BDEW(Bundesverbandder Energie- undWasserwirtschafte.V.)",X, - 59,Bilanzierungsgebiet/ Regelzone,SG2,LOC,,00024,,,,,[1] Wenn IMD+Z03 vorhanden - 60,Bilanzierungsgebiet/ Regelzone,SG2,LOC,3227,00024,107,,Bilanzierungsgebiet,, - 61,Bilanzierungsgebiet/ Regelzone,SG2,LOC,3227,,231,,Regelzone,,[36] Wenn MP-ID in SG2 NAD+MR mit Rolle NB nicht vorhanden - 62,Bilanzierungsgebiet/ Regelzone,SG2,LOC,3225,00024,,,Bilanzierungsgebiet/Regelzone,, - 63,Positionsdaten,SG29,,,,,,,Muss[2050],[2050] Pro Nachricht ist die SG29 genau einmal anzugeben - 64,Positionsdaten,SG29,LIN,,00040,,,,Muss, - 65,Positionsdaten,SG29,LIN,1082,00040,,,Positionsnummer,X [903],[903] Format: Möglicher Wert: 1 - 66,Profilgruppe,SG30,,,,,,,Muss, - 67,Profilgruppe,SG30,CCI,,00050,,,,Muss, - 68,Profilgruppe,SG30,CCI,7059,00050,Z02,,Standardlastprofil,X, - 69,Profilgruppe,SG30,CCI,7059,,Z03,,tagesparameterabhängiges Lastprofil,X, - 70,Profilgruppe,SG30,CCI,7059,,Z04,,Standardeinspeiseprofil,X, - 71,Profilgruppe,SG30,CCI,7059,,Z05,,tagesparameterabhängigesEinspeiseprofil,X, - 72,Versionsangabe der Summenzeitreihe,SG34,,,,,,,,[1] Wenn IMD+Z03 vorhanden - 73,Versionsangabe der Summenzeitreihe,SG34,RFF,,00060,,,,, - 74,Versionsangabe der Summenzeitreihe,SG34,RFF,1153,00060,AUU,,Referenz auf eineZeitreihe,, - 75,Versionsangabe der Summenzeitreihe,SG34,RFF,1154,00060,,,Version,, - 76,Meldepunkt,SG38,,,,,,,, - 77,Meldepunkt,SG38,LOC,,00063,,,,, - 78,Meldepunkt,SG38,LOC,3227,00063,172,,Meldepunkt,, - 79,Meldepunkt,SG38,LOC,3225,00063,,,Meldepunkt,,"[500] Hinweis: Zählpunkt der BAS - [501] Hinweis: Zählpunkt der DZR - [951] Format: Zählpunktbezeichnu ng" - 80,Bilanzkreis für Strom,SG38,,,,,,,, - 81,Bilanzkreis für Strom,SG38,LOC,,00064,,,,, - 82,Bilanzkreis für Strom,SG38,LOC,3227,00064,237,,Bilanzkreis,, - 83,Bilanzkreis für Strom,SG38,LOC,3225,00064,,,Bilanzkreis,, - 84,Abschnitts- Kontrollsegment,,UNS,,00123,,,,Muss, - 85,Abschnitts- Kontrollsegment,,UNS,0081,00123,S,,Trennung vonPositions- undSummenteil,X, - 86,Nachrichten- Endesegment,,UNT,,00125,,,,Muss, - 87,Nachrichten- Endesegment,,UNT,0074,00125,,,Anzahl der Segmente ineiner Nachricht,X, - 88,Nachrichten- Endesegment,,UNT,0062,00125,,,Nachrichten-Referenznummer,X, - - ''', - '17202.csv': ''' - ,Segmentname,Segmentgruppe,Segment,Datenelement,Segment ID,Code,Qualifier,Beschreibung,Bedingungsausdruck,Bedingung - 0,Nachrichten-Kopfsegment,,UNH,,00001,,,,Muss, - 1,Nachrichten-Kopfsegment,,UNH,0062,00001,,,Nachrichten-Referenznummer,X, - 2,Nachrichten-Kopfsegment,,UNH,0065,00001,ORDERS,,Bestellung,X, - 3,Nachrichten-Kopfsegment,,UNH,0052,00001,D,,Entwurfs-Version,X, - 4,Nachrichten-Kopfsegment,,UNH,0054,00001,09B,,Ausgabe 2009 - B,X, - 5,Nachrichten-Kopfsegment,,UNH,0051,00001,UN,,UN/CEFACT,X, - 6,Nachrichten-Kopfsegment,,UNH,0057,00001,1.3,,VersionsnummerderzugrundeliegendenBDEW-Nachrichtenbeschreibung,X, - 7,Beginn der Nachricht,,BGM,,00002,,,,Muss, - 8,Beginn der Nachricht,,BGM,1001,00002,E40,,Bilanzkreiszuordnungsliste,, - 9,Beginn der Nachricht,,BGM,1001,,Z05,,Clearingliste,X, - 10,Beginn der Nachricht,,BGM,1001,,Z19,,normiertes Profil/Profilschar,, - 11,Beginn der Nachricht,,BGM,1004,00002,,,Dokumentennummer,X, - 12,Nachrichtendatum,,DTM,,00003,,,,Muss, - 13,Nachrichtendatum,,DTM,2005,00003,137,,Dokumenten-/Nachrichtendatum/-zeit,X, - 14,Nachrichtendatum,,DTM,2380,00003,,,"Datum oder Uhrzeit oderZeitspanne, Wert",X [931][494],"[494] Das hier genannte Datum muss der Zeitpunkt sein, zu dem das Dokument erstellt wurde, oder ein Zeitpunkt, der davor liegt. - [931] Format: ZZZ = +00" - 15,Nachrichtendatum,,DTM,2379,00003,303,,CCYYMMDDHHMMZZZ,X, - 16,Ausführungsdatum,,DTM,,00004,,,,Muss [33]⊻ [34],"[33] Wenn IMD+Z01 vorhanden - [34] Wenn IMD+Z02 vorhanden" - 17,Ausführungsdatum,,DTM,2005,00004,203,,Ausführungsdatum/-zeit,X, - 18,Ausführungsdatum,,DTM,2380,00004,,,Datum oder Uhrzeit oder,X [UB1], - 19,Ausführungsdatum,,DTM,2379,00004,303,,CCYYMMDDHHMMZZZ,X, - 20,Betrachtungszeitintervall,,DTM,,00006,,,,Muss [1],[1] Wenn IMD+Z03 vorhanden - 21,Betrachtungszeitintervall,,DTM,2005,00006,273,,Gültigkeitszeitspanne,X, - 22,Betrachtungszeitintervall,,DTM,2380,00006,,,"Datum oder Uhrzeit oderZeitspanne, Wert",X, - 23,Betrachtungszeitintervall,,DTM,2379,00006,610,,CCYYMM,X, - 24,Abonnement,,IMD,,00008,,,,Muss, - 25,Abonnement,,IMD,7081,00008,Z01,,Start Abo,X, - 26,Abonnement,,IMD,7081,,Z02,,Ende Abo,X, - 27,Abonnement,,IMD,7081,,Z03,,ohne Abo,X, - 28,Prüfidentifikator,SG1,,,,,,,Muss, - 29,Prüfidentifikator,SG1,RFF,,00019,,,,Muss, - 30,Prüfidentifikator,SG1,RFF,1153,00019,Z13,,Prüfidentifikator,X, - 31,Prüfidentifikator,SG1,RFF,1154,00019,17201,,AnforderungnormierterProfile/Profilscharen,, - 32,Prüfidentifikator,SG1,RFF,1154,,17202,,AnforderungLieferantenclearingliste,X, - 33,Prüfidentifikator,SG1,RFF,1154,,17203,,AnforderungBilanzkreiszuordnungsliste,, - 34,Prüfidentifikator,SG1,RFF,1154,,17204,,AnforderungClearingliste BAS,, - 35,Prüfidentifikator,SG1,RFF,1154,,17205,,AnforderungClearingliste DZR,, - 36,MP-ID Absender,SG2,,,,,,,Muss, - 37,MP-ID Absender,SG2,NAD,,00020,,,,Muss, - 38,MP-ID Absender,SG2,NAD,3035,00020,MS,,Dokumenten-/Nachrichtenaussteller bzw. -absender,X, - 39,MP-ID Absender,SG2,NAD,3039,00020,,,MP-ID,X [61],[61] MP-ID nur aus Sparte Strom - 40,MP-ID Absender,SG2,NAD,3055,00020,9,,GS1,X, - 41,MP-ID Absender,SG2,NAD,3055,,293,,"DE, BDEW(Bundesverbandder Energie- undWasserwirtschafte.V.)",X, - 42,Ansprechpartner,SG5,,,,,,,Kann, - 43,Ansprechpartner,SG5,CTA,,00021,,,,Muss, - 44,Ansprechpartner,SG5,CTA,3139,00021,IC,,Informationskontakt,X, - 45,Ansprechpartner,SG5,CTA,3412,00021,,,Kontakt,X, - 46,Kommunikationsverbindu ng,SG5,COM,,00022,,,,Muss, - 47,Kommunikationsverbindu ng,SG5,COM,3148,00022,,,"Kommunikationsadresse,Identifikation",X, - 48,Kommunikationsverbindu ng,SG5,COM,3155,00022,EM,,Elektronische Post,X [1P0..1], - 49,Kommunikationsverbindu ng,SG5,COM,3155,,FX,,Telefax,X [1P0..1], - 50,Kommunikationsverbindu ng,SG5,COM,3155,,TE,,Telefon,X [1P0..1], - 51,Kommunikationsverbindu ng,SG5,COM,3155,,AJ,,weiteres Telefon,X [1P0..1], - 52,Kommunikationsverbindu ng,SG5,COM,3155,,AL,,Handy,X [1P0..1], - 53,MP-ID Empfänger,SG2,,,,,,,Muss, - 54,MP-ID Empfänger,SG2,NAD,,00023,,,,Muss, - 55,MP-ID Empfänger,SG2,NAD,3035,00023,MR,,Nachrichtenempfänger,X, - 56,MP-ID Empfänger,SG2,NAD,3039,00023,,,MP-ID,X [61],[61] MP-ID nur aus Sparte Strom - 57,MP-ID Empfänger,SG2,NAD,3055,00023,9,,GS1,X, - 58,MP-ID Empfänger,SG2,NAD,3055,,293,,"DE, BDEW(Bundesverbandder Energie- undWasserwirtschafte.V.)",X, - 59,Bilanzierungsgebiet/ Regelzone,SG2,LOC,,00024,,,,,[1] Wenn IMD+Z03 vorhanden - 60,Bilanzierungsgebiet/ Regelzone,SG2,LOC,3227,00024,107,,Bilanzierungsgebiet,, - 61,Bilanzierungsgebiet/ Regelzone,SG2,LOC,3227,,231,,Regelzone,,[36] Wenn MP-ID in SG2 NAD+MR mit Rolle NB nicht vorhanden - 62,Bilanzierungsgebiet/ Regelzone,SG2,LOC,3225,00024,,,Bilanzierungsgebiet/Regelzone,, - 63,Positionsdaten,SG29,,,,,,,Muss[2050],[2050] Pro Nachricht ist die SG29 genau einmal anzugeben - 64,Positionsdaten,SG29,LIN,,00040,,,,Muss, - 65,Positionsdaten,SG29,LIN,1082,00040,,,Positionsnummer,X [903],[903] Format: Möglicher Wert: 1 - 66,Profilgruppe,SG30,,,,,,,, - 67,Profilgruppe,SG30,CCI,,00050,,,,, - 68,Profilgruppe,SG30,CCI,7059,00050,Z02,,Standardlastprofil,, - 69,Profilgruppe,SG30,CCI,7059,,Z03,,tagesparameterabhängiges Lastprofil,, - 70,Profilgruppe,SG30,CCI,7059,,Z04,,Standardeinspeiseprofil,, - 71,Profilgruppe,SG30,CCI,7059,,Z05,,tagesparameterabhängigesEinspeiseprofil,, - 72,Versionsangabe der Summenzeitreihe,SG34,,,,,,,Muss [1],[1] Wenn IMD+Z03 vorhanden - 73,Versionsangabe der Summenzeitreihe,SG34,RFF,,00060,,,,Muss, - 74,Versionsangabe der Summenzeitreihe,SG34,RFF,1153,00060,AUU,,Referenz auf eineZeitreihe,X, - 75,Versionsangabe der Summenzeitreihe,SG34,RFF,1154,00060,,,Version,X, - 76,Meldepunkt,SG38,,,,,,,Muss, - 77,Meldepunkt,SG38,LOC,,00063,,,,Muss, - 78,Meldepunkt,SG38,LOC,3227,00063,172,,Meldepunkt,X, - 79,Meldepunkt,SG38,LOC,3225,00063,,,Meldepunkt,X [951],"[500] Hinweis: Zählpunkt der BAS - [501] Hinweis: Zählpunkt der DZR - [951] Format: Zählpunktbezeichnu ng" - 80,Bilanzkreis für Strom,SG38,,,,,,,, - 81,Bilanzkreis für Strom,SG38,LOC,,00064,,,,, - 82,Bilanzkreis für Strom,SG38,LOC,3227,00064,237,,Bilanzkreis,, - 83,Bilanzkreis für Strom,SG38,LOC,3225,00064,,,Bilanzkreis,, - 84,Abschnitts- Kontrollsegment,,UNS,,00123,,,,Muss, - 85,Abschnitts- Kontrollsegment,,UNS,0081,00123,S,,Trennung vonPositions- undSummenteil,X, - 86,Nachrichten- Endesegment,,UNT,,00125,,,,Muss, - 87,Nachrichten- Endesegment,,UNT,0074,00125,,,Anzahl der Segmente ineiner Nachricht,X, - 88,Nachrichten- Endesegment,,UNT,0062,00125,,,Nachrichten-Referenznummer,X, - - ''', - '17203.csv': ''' - ,Segmentname,Segmentgruppe,Segment,Datenelement,Segment ID,Code,Qualifier,Beschreibung,Bedingungsausdruck,Bedingung - 0,Nachrichten-Kopfsegment,,UNH,,00001,,,,Muss, - 1,Nachrichten-Kopfsegment,,UNH,0062,00001,,,Nachrichten-Referenznummer,X, - 2,Nachrichten-Kopfsegment,,UNH,0065,00001,ORDERS,,Bestellung,X, - 3,Nachrichten-Kopfsegment,,UNH,0052,00001,D,,Entwurfs-Version,X, - 4,Nachrichten-Kopfsegment,,UNH,0054,00001,09B,,Ausgabe 2009 - B,X, - 5,Nachrichten-Kopfsegment,,UNH,0051,00001,UN,,UN/CEFACT,X, - 6,Nachrichten-Kopfsegment,,UNH,0057,00001,1.3,,VersionsnummerderzugrundeliegendenBDEW-Nachrichtenbeschreibung,X, - 7,Beginn der Nachricht,,BGM,,00002,,,,Muss, - 8,Beginn der Nachricht,,BGM,1001,00002,E40,,Bilanzkreiszuordnungsliste,X, - 9,Beginn der Nachricht,,BGM,1001,,Z05,,Clearingliste,, - 10,Beginn der Nachricht,,BGM,1001,,Z19,,normiertes Profil/Profilschar,, - 11,Beginn der Nachricht,,BGM,1004,00002,,,Dokumentennummer,X, - 12,Nachrichtendatum,,DTM,,00003,,,,Muss, - 13,Nachrichtendatum,,DTM,2005,00003,137,,Dokumenten-/Nachrichtendatum/-zeit,X, - 14,Nachrichtendatum,,DTM,2380,00003,,,"Datum oder Uhrzeit oderZeitspanne, Wert",X [931][494],"[494] Das hier genannte Datum muss der Zeitpunkt sein, zu dem das Dokument erstellt wurde, oder ein Zeitpunkt, der davor liegt. - [931] Format: ZZZ = +00" - 15,Nachrichtendatum,,DTM,2379,00003,303,,CCYYMMDDHHMMZZZ,X, - 16,Ausführungsdatum,,DTM,,00004,,,,Muss [33]⊻ [34],"[33] Wenn IMD+Z01 vorhanden - [34] Wenn IMD+Z02 vorhanden" - 17,Ausführungsdatum,,DTM,2005,00004,203,,Ausführungsdatum/-zeit,X, - 18,Ausführungsdatum,,DTM,2380,00004,,,Datum oder Uhrzeit oder,X [UB1], - 19,Ausführungsdatum,,DTM,2379,00004,303,,CCYYMMDDHHMMZZZ,X, - 20,Betrachtungszeitintervall,,DTM,,00006,,,,Muss [1],[1] Wenn IMD+Z03 vorhanden - 21,Betrachtungszeitintervall,,DTM,2005,00006,273,,Gültigkeitszeitspanne,X, - 22,Betrachtungszeitintervall,,DTM,2380,00006,,,"Datum oder Uhrzeit oderZeitspanne, Wert",X, - 23,Betrachtungszeitintervall,,DTM,2379,00006,610,,CCYYMM,X, - 24,Abonnement,,IMD,,00008,,,,Muss, - 25,Abonnement,,IMD,7081,00008,Z01,,Start Abo,X, - 26,Abonnement,,IMD,7081,,Z02,,Ende Abo,X, - 27,Abonnement,,IMD,7081,,Z03,,ohne Abo,X, - 28,Prüfidentifikator,SG1,,,,,,,Muss, - 29,Prüfidentifikator,SG1,RFF,,00019,,,,Muss, - 30,Prüfidentifikator,SG1,RFF,1153,00019,Z13,,Prüfidentifikator,X, - 31,Prüfidentifikator,SG1,RFF,1154,00019,17201,,AnforderungnormierterProfile/Profilscharen,, - 32,Prüfidentifikator,SG1,RFF,1154,,17202,,AnforderungLieferantenclearingliste,, - 33,Prüfidentifikator,SG1,RFF,1154,,17203,,AnforderungBilanzkreiszuordnungsliste,X, - 34,Prüfidentifikator,SG1,RFF,1154,,17204,,AnforderungClearingliste BAS,, - 35,Prüfidentifikator,SG1,RFF,1154,,17205,,AnforderungClearingliste DZR,, - 36,MP-ID Absender,SG2,,,,,,,Muss, - 37,MP-ID Absender,SG2,NAD,,00020,,,,Muss, - 38,MP-ID Absender,SG2,NAD,3035,00020,MS,,Dokumenten-/Nachrichtenaussteller bzw. -absender,X, - 39,MP-ID Absender,SG2,NAD,3039,00020,,,MP-ID,X [61],[61] MP-ID nur aus Sparte Strom - 40,MP-ID Absender,SG2,NAD,3055,00020,9,,GS1,X, - 41,MP-ID Absender,SG2,NAD,3055,,293,,"DE, BDEW(Bundesverbandder Energie- undWasserwirtschafte.V.)",X, - 42,Ansprechpartner,SG5,,,,,,,Kann, - 43,Ansprechpartner,SG5,CTA,,00021,,,,Muss, - 44,Ansprechpartner,SG5,CTA,3139,00021,IC,,Informationskontakt,X, - 45,Ansprechpartner,SG5,CTA,3412,00021,,,Kontakt,X, - 46,Kommunikationsverbindu ng,SG5,COM,,00022,,,,Muss, - 47,Kommunikationsverbindu ng,SG5,COM,3148,00022,,,"Kommunikationsadresse,Identifikation",X, - 48,Kommunikationsverbindu ng,SG5,COM,3155,00022,EM,,Elektronische Post,X [1P0..1], - 49,Kommunikationsverbindu ng,SG5,COM,3155,,FX,,Telefax,X [1P0..1], - 50,Kommunikationsverbindu ng,SG5,COM,3155,,TE,,Telefon,X [1P0..1], - 51,Kommunikationsverbindu ng,SG5,COM,3155,,AJ,,weiteres Telefon,X [1P0..1], - 52,Kommunikationsverbindu ng,SG5,COM,3155,,AL,,Handy,X [1P0..1], - 53,MP-ID Empfänger,SG2,,,,,,,Muss, - 54,MP-ID Empfänger,SG2,NAD,,00023,,,,Muss, - 55,MP-ID Empfänger,SG2,NAD,3035,00023,MR,,Nachrichtenempfänger,X, - 56,MP-ID Empfänger,SG2,NAD,3039,00023,,,MP-ID,X [61],[61] MP-ID nur aus Sparte Strom - 57,MP-ID Empfänger,SG2,NAD,3055,00023,9,,GS1,X, - 58,MP-ID Empfänger,SG2,NAD,3055,,293,,"DE, BDEW(Bundesverbandder Energie- undWasserwirtschafte.V.)",X, - 59,Bilanzierungsgebiet/ Regelzone,SG2,LOC,,00024,,,,Muss [1],[1] Wenn IMD+Z03 vorhanden - 60,Bilanzierungsgebiet/ Regelzone,SG2,LOC,3227,00024,107,,Bilanzierungsgebiet,X, - 61,Bilanzierungsgebiet/ Regelzone,SG2,LOC,3227,,231,,Regelzone,X [36],[36] Wenn MP-ID in SG2 NAD+MR mit Rolle NB nicht vorhanden - 62,Bilanzierungsgebiet/ Regelzone,SG2,LOC,3225,00024,,,Bilanzierungsgebiet/Regelzone,X, - 63,Positionsdaten,SG29,,,,,,,Muss[2050],[2050] Pro Nachricht ist die SG29 genau einmal anzugeben - 64,Positionsdaten,SG29,LIN,,00040,,,,Muss, - 65,Positionsdaten,SG29,LIN,1082,00040,,,Positionsnummer,X [903],[903] Format: Möglicher Wert: 1 - 66,Profilgruppe,SG30,,,,,,,, - 67,Profilgruppe,SG30,CCI,,00050,,,,, - 68,Profilgruppe,SG30,CCI,7059,00050,Z02,,Standardlastprofil,, - 69,Profilgruppe,SG30,CCI,7059,,Z03,,tagesparameterabhängiges Lastprofil,, - 70,Profilgruppe,SG30,CCI,7059,,Z04,,Standardeinspeiseprofil,, - 71,Profilgruppe,SG30,CCI,7059,,Z05,,tagesparameterabhängigesEinspeiseprofil,, - 72,Versionsangabe der Summenzeitreihe,SG34,,,,,,,,[1] Wenn IMD+Z03 vorhanden - 73,Versionsangabe der Summenzeitreihe,SG34,RFF,,00060,,,,, - 74,Versionsangabe der Summenzeitreihe,SG34,RFF,1153,00060,AUU,,Referenz auf eineZeitreihe,, - 75,Versionsangabe der Summenzeitreihe,SG34,RFF,1154,00060,,,Version,, - 76,Meldepunkt,SG38,,,,,,,, - 77,Meldepunkt,SG38,LOC,,00063,,,,, - 78,Meldepunkt,SG38,LOC,3227,00063,172,,Meldepunkt,, - 79,Meldepunkt,SG38,LOC,3225,00063,,,Meldepunkt,,"[500] Hinweis: Zählpunkt der BAS - [501] Hinweis: Zählpunkt der DZR - [951] Format: Zählpunktbezeichnu ng" - 80,Bilanzkreis für Strom,SG38,,,,,,,Muss, - 81,Bilanzkreis für Strom,SG38,LOC,,00064,,,,Muss, - 82,Bilanzkreis für Strom,SG38,LOC,3227,00064,237,,Bilanzkreis,X, - 83,Bilanzkreis für Strom,SG38,LOC,3225,00064,,,Bilanzkreis,X, - 84,Abschnitts- Kontrollsegment,,UNS,,00123,,,,Muss, - 85,Abschnitts- Kontrollsegment,,UNS,0081,00123,S,,Trennung vonPositions- undSummenteil,X, - 86,Nachrichten- Endesegment,,UNT,,00125,,,,Muss, - 87,Nachrichten- Endesegment,,UNT,0074,00125,,,Anzahl der Segmente ineiner Nachricht,X, - 88,Nachrichten- Endesegment,,UNT,0062,00125,,,Nachrichten-Referenznummer,X, - - ''', - '17204.csv': ''' - ,Segmentname,Segmentgruppe,Segment,Datenelement,Segment ID,Code,Qualifier,Beschreibung,Bedingungsausdruck,Bedingung - 0,Nachrichten-Kopfsegment,,UNH,,00001,,,,Muss, - 1,Nachrichten-Kopfsegment,,UNH,0062,00001,,,Nachrichten-Referenznummer,X, - 2,Nachrichten-Kopfsegment,,UNH,0065,00001,ORDERS,,Bestellung,X, - 3,Nachrichten-Kopfsegment,,UNH,0052,00001,D,,Entwurfs-Version,X, - 4,Nachrichten-Kopfsegment,,UNH,0054,00001,09B,,Ausgabe 2009 - B,X, - 5,Nachrichten-Kopfsegment,,UNH,0051,00001,UN,,UN/CEFACT,X, - 6,Nachrichten-Kopfsegment,,UNH,0057,00001,1.3,,VersionsnummerderzugrundeliegendenBDEW-Nachrichtenbeschreibung,X, - 7,Beginn der Nachricht,,BGM,,00002,,,,Muss, - 8,Beginn der Nachricht,,BGM,1001,00002,E40,,Bilanzkreiszuordnungsliste,, - 9,Beginn der Nachricht,,BGM,1001,,Z05,,Clearingliste,X, - 10,Beginn der Nachricht,,BGM,1001,,Z19,,normiertes Profil/Profilschar,, - 11,Beginn der Nachricht,,BGM,1004,00002,,,Dokumentennummer,X, - 12,Nachrichtendatum,,DTM,,00003,,,,Muss, - 13,Nachrichtendatum,,DTM,2005,00003,137,,Dokumenten-/Nachrichtendatum/-zeit,X, - 14,Nachrichtendatum,,DTM,2380,00003,,,"Datum oder Uhrzeit oderZeitspanne, Wert",X [931][494],"[494] Das hier genannte Datum muss der Zeitpunkt sein, zu dem das Dokument erstellt wurde, oder ein Zeitpunkt, der davor liegt. - [931] Format: ZZZ = +00" - 15,Nachrichtendatum,,DTM,2379,00003,303,,CCYYMMDDHHMMZZZ,X, - 16,Ausführungsdatum,,DTM,,00004,,,,,"[33] Wenn IMD+Z01 vorhanden - [34] Wenn IMD+Z02 vorhanden" - 17,Ausführungsdatum,,DTM,2005,00004,203,,Ausführungsdatum/-zeit,, - 18,Ausführungsdatum,,DTM,2380,00004,,,Datum oder Uhrzeit oder,, - 19,Ausführungsdatum,,DTM,2379,00004,303,,CCYYMMDDHHMMZZZ,, - 20,Betrachtungszeitintervall,,DTM,,00006,,,,Muss,[1] Wenn IMD+Z03 vorhanden - 21,Betrachtungszeitintervall,,DTM,2005,00006,273,,Gültigkeitszeitspanne,X, - 22,Betrachtungszeitintervall,,DTM,2380,00006,,,"Datum oder Uhrzeit oderZeitspanne, Wert",X, - 23,Betrachtungszeitintervall,,DTM,2379,00006,610,,CCYYMM,X, - 24,Abonnement,,IMD,,00008,,,,Muss, - 25,Abonnement,,IMD,7081,00008,Z01,,Start Abo,, - 26,Abonnement,,IMD,7081,,Z02,,Ende Abo,, - 27,Abonnement,,IMD,7081,,Z03,,ohne Abo,X, - 28,Prüfidentifikator,SG1,,,,,,,Muss, - 29,Prüfidentifikator,SG1,RFF,,00019,,,,Muss, - 30,Prüfidentifikator,SG1,RFF,1153,00019,Z13,,Prüfidentifikator,X, - 31,Prüfidentifikator,SG1,RFF,1154,00019,17201,,AnforderungnormierterProfile/Profilscharen,, - 32,Prüfidentifikator,SG1,RFF,1154,,17202,,AnforderungLieferantenclearingliste,, - 33,Prüfidentifikator,SG1,RFF,1154,,17203,,AnforderungBilanzkreiszuordnungsliste,, - 34,Prüfidentifikator,SG1,RFF,1154,,17204,,AnforderungClearingliste BAS,X, - 35,Prüfidentifikator,SG1,RFF,1154,,17205,,AnforderungClearingliste DZR,, - 36,MP-ID Absender,SG2,,,,,,,Muss, - 37,MP-ID Absender,SG2,NAD,,00020,,,,Muss, - 38,MP-ID Absender,SG2,NAD,3035,00020,MS,,Dokumenten-/Nachrichtenaussteller bzw. -absender,X, - 39,MP-ID Absender,SG2,NAD,3039,00020,,,MP-ID,X [61],[61] MP-ID nur aus Sparte Strom - 40,MP-ID Absender,SG2,NAD,3055,00020,9,,GS1,X, - 41,MP-ID Absender,SG2,NAD,3055,,293,,"DE, BDEW(Bundesverbandder Energie- undWasserwirtschafte.V.)",X, - 42,Ansprechpartner,SG5,,,,,,,Kann, - 43,Ansprechpartner,SG5,CTA,,00021,,,,Muss, - 44,Ansprechpartner,SG5,CTA,3139,00021,IC,,Informationskontakt,X, - 45,Ansprechpartner,SG5,CTA,3412,00021,,,Kontakt,X, - 46,Kommunikationsverbindu ng,SG5,COM,,00022,,,,Muss, - 47,Kommunikationsverbindu ng,SG5,COM,3148,00022,,,"Kommunikationsadresse,Identifikation",X, - 48,Kommunikationsverbindu ng,SG5,COM,3155,00022,EM,,Elektronische Post,X [1P0..1], - 49,Kommunikationsverbindu ng,SG5,COM,3155,,FX,,Telefax,X [1P0..1], - 50,Kommunikationsverbindu ng,SG5,COM,3155,,TE,,Telefon,X [1P0..1], - 51,Kommunikationsverbindu ng,SG5,COM,3155,,AJ,,weiteres Telefon,X [1P0..1], - 52,Kommunikationsverbindu ng,SG5,COM,3155,,AL,,Handy,X [1P0..1], - 53,MP-ID Empfänger,SG2,,,,,,,Muss, - 54,MP-ID Empfänger,SG2,NAD,,00023,,,,Muss, - 55,MP-ID Empfänger,SG2,NAD,3035,00023,MR,,Nachrichtenempfänger,X, - 56,MP-ID Empfänger,SG2,NAD,3039,00023,,,MP-ID,X [61],[61] MP-ID nur aus Sparte Strom - 57,MP-ID Empfänger,SG2,NAD,3055,00023,9,,GS1,X, - 58,MP-ID Empfänger,SG2,NAD,3055,,293,,"DE, BDEW(Bundesverbandder Energie- undWasserwirtschafte.V.)",X, - 59,Bilanzierungsgebiet/ Regelzone,SG2,LOC,,00024,,,,,[1] Wenn IMD+Z03 vorhanden - 60,Bilanzierungsgebiet/ Regelzone,SG2,LOC,3227,00024,107,,Bilanzierungsgebiet,, - 61,Bilanzierungsgebiet/ Regelzone,SG2,LOC,3227,,231,,Regelzone,,[36] Wenn MP-ID in SG2 NAD+MR mit Rolle NB nicht vorhanden - 62,Bilanzierungsgebiet/ Regelzone,SG2,LOC,3225,00024,,,Bilanzierungsgebiet/Regelzone,, - 63,Positionsdaten,SG29,,,,,,,Muss[2050],[2050] Pro Nachricht ist die SG29 genau einmal anzugeben - 64,Positionsdaten,SG29,LIN,,00040,,,,Muss, - 65,Positionsdaten,SG29,LIN,1082,00040,,,Positionsnummer,X [903],[903] Format: Möglicher Wert: 1 - 66,Profilgruppe,SG30,,,,,,,, - 67,Profilgruppe,SG30,CCI,,00050,,,,, - 68,Profilgruppe,SG30,CCI,7059,00050,Z02,,Standardlastprofil,, - 69,Profilgruppe,SG30,CCI,7059,,Z03,,tagesparameterabhängiges Lastprofil,, - 70,Profilgruppe,SG30,CCI,7059,,Z04,,Standardeinspeiseprofil,, - 71,Profilgruppe,SG30,CCI,7059,,Z05,,tagesparameterabhängigesEinspeiseprofil,, - 72,Versionsangabe der Summenzeitreihe,SG34,,,,,,,Muss,[1] Wenn IMD+Z03 vorhanden - 73,Versionsangabe der Summenzeitreihe,SG34,RFF,,00060,,,,Muss, - 74,Versionsangabe der Summenzeitreihe,SG34,RFF,1153,00060,AUU,,Referenz auf eineZeitreihe,X, - 75,Versionsangabe der Summenzeitreihe,SG34,RFF,1154,00060,,,Version,X, - 76,Meldepunkt,SG38,,,,,,,Muss, - 77,Meldepunkt,SG38,LOC,,00063,,,,Muss, - 78,Meldepunkt,SG38,LOC,3227,00063,172,,Meldepunkt,X, - 79,Meldepunkt,SG38,LOC,3225,00063,,,Meldepunkt,X [951][500],"[500] Hinweis: Zählpunkt der BAS - [501] Hinweis: Zählpunkt der DZR - [951] Format: Zählpunktbezeichnu ng" - 80,Bilanzkreis für Strom,SG38,,,,,,,, - 81,Bilanzkreis für Strom,SG38,LOC,,00064,,,,, - 82,Bilanzkreis für Strom,SG38,LOC,3227,00064,237,,Bilanzkreis,, - 83,Bilanzkreis für Strom,SG38,LOC,3225,00064,,,Bilanzkreis,, - 84,Abschnitts- Kontrollsegment,,UNS,,00123,,,,Muss, - 85,Abschnitts- Kontrollsegment,,UNS,0081,00123,S,,Trennung vonPositions- undSummenteil,X, - 86,Nachrichten- Endesegment,,UNT,,00125,,,,Muss, - 87,Nachrichten- Endesegment,,UNT,0074,00125,,,Anzahl der Segmente ineiner Nachricht,X, - 88,Nachrichten- Endesegment,,UNT,0062,00125,,,Nachrichten-Referenznummer,X, - - ''', - '17205.csv': ''' - ,Segmentname,Segmentgruppe,Segment,Datenelement,Segment ID,Code,Qualifier,Beschreibung,Bedingungsausdruck,Bedingung - 0,Nachrichten-Kopfsegment,,UNH,,00001,,,,Muss, - 1,Nachrichten-Kopfsegment,,UNH,0062,00001,,,Nachrichten-Referenznummer,X, - 2,Nachrichten-Kopfsegment,,UNH,0065,00001,ORDERS,,Bestellung,X, - 3,Nachrichten-Kopfsegment,,UNH,0052,00001,D,,Entwurfs-Version,X, - 4,Nachrichten-Kopfsegment,,UNH,0054,00001,09B,,Ausgabe 2009 - B,X, - 5,Nachrichten-Kopfsegment,,UNH,0051,00001,UN,,UN/CEFACT,X, - 6,Nachrichten-Kopfsegment,,UNH,0057,00001,1.3,,VersionsnummerderzugrundeliegendenBDEW-Nachrichtenbeschreibung,X, - 7,Beginn der Nachricht,,BGM,,00002,,,,Muss, - 8,Beginn der Nachricht,,BGM,1001,00002,E40,,Bilanzkreiszuordnungsliste,, - 9,Beginn der Nachricht,,BGM,1001,,Z05,,Clearingliste,X, - 10,Beginn der Nachricht,,BGM,1001,,Z19,,normiertes Profil/Profilschar,, - 11,Beginn der Nachricht,,BGM,1004,00002,,,Dokumentennummer,X, - 12,Nachrichtendatum,,DTM,,00003,,,,Muss, - 13,Nachrichtendatum,,DTM,2005,00003,137,,Dokumenten-/Nachrichtendatum/-zeit,X, - 14,Nachrichtendatum,,DTM,2380,00003,,,"Datum oder Uhrzeit oderZeitspanne, Wert",X [931][494],"[494] Das hier genannte Datum muss der Zeitpunkt sein, zu dem das Dokument erstellt wurde, oder ein Zeitpunkt, der davor liegt. - [931] Format: ZZZ = +00" - 15,Nachrichtendatum,,DTM,2379,00003,303,,CCYYMMDDHHMMZZZ,X, - 16,Ausführungsdatum,,DTM,,00004,,,,,"[33] Wenn IMD+Z01 vorhanden - [34] Wenn IMD+Z02 vorhanden" - 17,Ausführungsdatum,,DTM,2005,00004,203,,Ausführungsdatum/-zeit,, - 18,Ausführungsdatum,,DTM,2380,00004,,,Datum oder Uhrzeit oder,, - 19,Ausführungsdatum,,DTM,2379,00004,303,,CCYYMMDDHHMMZZZ,, - 20,Betrachtungszeitintervall,,DTM,,00006,,,,Muss,[1] Wenn IMD+Z03 vorhanden - 21,Betrachtungszeitintervall,,DTM,2005,00006,273,,Gültigkeitszeitspanne,X, - 22,Betrachtungszeitintervall,,DTM,2380,00006,,,"Datum oder Uhrzeit oderZeitspanne, Wert",X, - 23,Betrachtungszeitintervall,,DTM,2379,00006,610,,CCYYMM,X, - 24,Abonnement,,IMD,,00008,,,,Muss, - 25,Abonnement,,IMD,7081,00008,Z01,,Start Abo,, - 26,Abonnement,,IMD,7081,,Z02,,Ende Abo,, - 27,Abonnement,,IMD,7081,,Z03,,ohne Abo,X, - 28,Prüfidentifikator,SG1,,,,,,,Muss, - 29,Prüfidentifikator,SG1,RFF,,00019,,,,Muss, - 30,Prüfidentifikator,SG1,RFF,1153,00019,Z13,,Prüfidentifikator,X, - 31,Prüfidentifikator,SG1,RFF,1154,00019,17201,,AnforderungnormierterProfile/Profilscharen,, - 32,Prüfidentifikator,SG1,RFF,1154,,17202,,AnforderungLieferantenclearingliste,, - 33,Prüfidentifikator,SG1,RFF,1154,,17203,,AnforderungBilanzkreiszuordnungsliste,, - 34,Prüfidentifikator,SG1,RFF,1154,,17204,,AnforderungClearingliste BAS,, - 35,Prüfidentifikator,SG1,RFF,1154,,17205,,AnforderungClearingliste DZR,X, - 36,MP-ID Absender,SG2,,,,,,,Muss, - 37,MP-ID Absender,SG2,NAD,,00020,,,,Muss, - 38,MP-ID Absender,SG2,NAD,3035,00020,MS,,Dokumenten-/Nachrichtenaussteller bzw. -absender,X, - 39,MP-ID Absender,SG2,NAD,3039,00020,,,MP-ID,X [61],[61] MP-ID nur aus Sparte Strom - 40,MP-ID Absender,SG2,NAD,3055,00020,9,,GS1,X, - 41,MP-ID Absender,SG2,NAD,3055,,293,,"DE, BDEW(Bundesverbandder Energie- undWasserwirtschafte.V.)",X, - 42,Ansprechpartner,SG5,,,,,,,Kann, - 43,Ansprechpartner,SG5,CTA,,00021,,,,Muss, - 44,Ansprechpartner,SG5,CTA,3139,00021,IC,,Informationskontakt,X, - 45,Ansprechpartner,SG5,CTA,3412,00021,,,Kontakt,X, - 46,Kommunikationsverbindu ng,SG5,COM,,00022,,,,Muss, - 47,Kommunikationsverbindu ng,SG5,COM,3148,00022,,,"Kommunikationsadresse,Identifikation",X, - 48,Kommunikationsverbindu ng,SG5,COM,3155,00022,EM,,Elektronische Post,X [1P0..1], - 49,Kommunikationsverbindu ng,SG5,COM,3155,,FX,,Telefax,X [1P0..1], - 50,Kommunikationsverbindu ng,SG5,COM,3155,,TE,,Telefon,X [1P0..1], - 51,Kommunikationsverbindu ng,SG5,COM,3155,,AJ,,weiteres Telefon,X [1P0..1], - 52,Kommunikationsverbindu ng,SG5,COM,3155,,AL,,Handy,X [1P0..1], - 53,MP-ID Empfänger,SG2,,,,,,,Muss, - 54,MP-ID Empfänger,SG2,NAD,,00023,,,,Muss, - 55,MP-ID Empfänger,SG2,NAD,3035,00023,MR,,Nachrichtenempfänger,X, - 56,MP-ID Empfänger,SG2,NAD,3039,00023,,,MP-ID,X [61],[61] MP-ID nur aus Sparte Strom - 57,MP-ID Empfänger,SG2,NAD,3055,00023,9,,GS1,X, - 58,MP-ID Empfänger,SG2,NAD,3055,,293,,"DE, BDEW(Bundesverbandder Energie- undWasserwirtschafte.V.)",X, - 59,Bilanzierungsgebiet/ Regelzone,SG2,LOC,,00024,,,,,[1] Wenn IMD+Z03 vorhanden - 60,Bilanzierungsgebiet/ Regelzone,SG2,LOC,3227,00024,107,,Bilanzierungsgebiet,, - 61,Bilanzierungsgebiet/ Regelzone,SG2,LOC,3227,,231,,Regelzone,,[36] Wenn MP-ID in SG2 NAD+MR mit Rolle NB nicht vorhanden - 62,Bilanzierungsgebiet/ Regelzone,SG2,LOC,3225,00024,,,Bilanzierungsgebiet/Regelzone,, - 63,Positionsdaten,SG29,,,,,,,Muss[2050],[2050] Pro Nachricht ist die SG29 genau einmal anzugeben - 64,Positionsdaten,SG29,LIN,,00040,,,,Muss, - 65,Positionsdaten,SG29,LIN,1082,00040,,,Positionsnummer,X [903],[903] Format: Möglicher Wert: 1 - 66,Profilgruppe,SG30,,,,,,,, - 67,Profilgruppe,SG30,CCI,,00050,,,,, - 68,Profilgruppe,SG30,CCI,7059,00050,Z02,,Standardlastprofil,, - 69,Profilgruppe,SG30,CCI,7059,,Z03,,tagesparameterabhängiges Lastprofil,, - 70,Profilgruppe,SG30,CCI,7059,,Z04,,Standardeinspeiseprofil,, - 71,Profilgruppe,SG30,CCI,7059,,Z05,,tagesparameterabhängigesEinspeiseprofil,, - 72,Versionsangabe der Summenzeitreihe,SG34,,,,,,,Muss,[1] Wenn IMD+Z03 vorhanden - 73,Versionsangabe der Summenzeitreihe,SG34,RFF,,00060,,,,Muss, - 74,Versionsangabe der Summenzeitreihe,SG34,RFF,1153,00060,AUU,,Referenz auf eineZeitreihe,X, - 75,Versionsangabe der Summenzeitreihe,SG34,RFF,1154,00060,,,Version,X, - 76,Meldepunkt,SG38,,,,,,,Muss, - 77,Meldepunkt,SG38,LOC,,00063,,,,Muss, - 78,Meldepunkt,SG38,LOC,3227,00063,172,,Meldepunkt,X, - 79,Meldepunkt,SG38,LOC,3225,00063,,,Meldepunkt,X [951][501],"[500] Hinweis: Zählpunkt der BAS - [501] Hinweis: Zählpunkt der DZR - [951] Format: Zählpunktbezeichnu ng" - 80,Bilanzkreis für Strom,SG38,,,,,,,, - 81,Bilanzkreis für Strom,SG38,LOC,,00064,,,,, - 82,Bilanzkreis für Strom,SG38,LOC,3227,00064,237,,Bilanzkreis,, - 83,Bilanzkreis für Strom,SG38,LOC,3225,00064,,,Bilanzkreis,, - 84,Abschnitts- Kontrollsegment,,UNS,,00123,,,,Muss, - 85,Abschnitts- Kontrollsegment,,UNS,0081,00123,S,,Trennung vonPositions- undSummenteil,X, - 86,Nachrichten- Endesegment,,UNT,,00125,,,,Muss, - 87,Nachrichten- Endesegment,,UNT,0074,00125,,,Anzahl der Segmente ineiner Nachricht,X, - 88,Nachrichten- Endesegment,,UNT,0062,00125,,,Nachrichten-Referenznummer,X, - - ''', - '17206.csv': ''' - ,Segmentname,Segmentgruppe,Segment,Datenelement,Segment ID,Code,Qualifier,Beschreibung,Bedingungsausdruck,Bedingung - 0,Nachrichten-Kopfsegment,,UNH,,00001,,,,Muss, - 1,Nachrichten-Kopfsegment,,UNH,0062,00001,,,Nachrichten-Referenznummer,X, - 2,Nachrichten-Kopfsegment,,UNH,0065,00001,ORDERS,,Bestellung,X, - 3,Nachrichten-Kopfsegment,,UNH,0052,00001,D,,Entwurfs-Version,X, - 4,Nachrichten-Kopfsegment,,UNH,0054,00001,09B,,Ausgabe 2009 - B,X, - 5,Nachrichten-Kopfsegment,,UNH,0051,00001,UN,,UN/CEFACT,X, - 6,Nachrichten-Kopfsegment,,UNH,0057,00001,1.3,,Versionsnummer derzugrundeliegendenBDEW-Nachrichtenbeschreibung,X, - 7,Beginn der Nachricht,,BGM,,00002,,,,Muss, - 8,Beginn der Nachricht,,BGM,1001,00002,Z05,,Clearingliste,X, - 9,Beginn der Nachricht,,BGM,1001,,BK,,Zeitreihen im RahmenderBilanzkreisabrechnung,, - 10,Beginn der Nachricht,,BGM,1004,00002,,,Dokumentennummer,X, - 11,Nachrichtendatum,,DTM,,00003,,,,Muss, - 12,Nachrichtendatum,,DTM,2005,00003,137,,Dokumenten-/Nachrichtendatum/-zeit,X, - 13,Nachrichtendatum,,DTM,2380,00003,,,"Datum oder Uhrzeit oderZeitspanne, Wert",X [931][494],"[494] Das hier genannte Datum muss der Zeitpunkt sein, zu dem das Dokument erstellt wurde, oder ein Zeitpunkt, der davor liegt. - [931] Format: ZZZ = +00" - 14,Nachrichtendatum,,DTM,2379,00003,303,,CCYYMMDDHHMMZZZ,X, - 15,Ausführungsdatum,,DTM,,00004,,,,Muss [33] ⊻[34],"[33] Wenn IMD+Z01 vorhanden - [34] Wenn IMD+Z02 vorhanden" - 16,Ausführungsdatum,,DTM,2005,00004,203,,Ausführungsdatum/-zeit,X, - 17,Ausführungsdatum,,DTM,2380,00004,,,"Datum oder Uhrzeit oderZeitspanne, Wert",X [UB1], - 18,Ausführungsdatum,,DTM,2379,00004,303,,CCYYMMDDHHMMZZZ,X, - 19,Betrachtungszeitintervall,,DTM,,00006,,,,Muss [1],[1] Wenn IMD+Z03 vorhanden - 20,Betrachtungszeitintervall,,DTM,2005,00006,273,,Gültigkeitszeitspanne,X, - 21,Betrachtungszeitintervall,,DTM,2380,00006,,,"Datum oder Uhrzeit oderZeitspanne, Wert",X, - 22,Betrachtungszeitintervall,,DTM,2379,00006,610,,CCYYMM,X, - 23,Abonnement,,IMD,,00008,,,,Muss, - 24,Abonnement,,IMD,7081,00008,Z01,,Start Abo,X, - 25,Abonnement,,IMD,7081,,Z02,,Ende Abo,X, - 26,Abonnement,,IMD,7081,,Z03,,ohne Abo,X, - 27,Prüfidentifikator,SG1,,,,,,,Muss, - 28,Prüfidentifikator,SG1,RFF,,00019,,,,Muss, - 29,Prüfidentifikator,SG1,RFF,1153,00019,Z13,,Prüfidentifikator,X, - 30,Prüfidentifikator,SG1,RFF,1154,00019,17206,,AnforderungBilanzierungsgebietsclearingliste,X, - 31,Prüfidentifikator,SG1,RFF,1154,,17207,,Ab-/Bestellung BK-SZRauf AggregationsebeneRZ,, - 32,Prüfidentifikator,SG1,RFF,1154,,17208,,AnforderungClearingliste ÜNB-DZR,, - 33,MP-ID Absender,SG2,,,,,,,Muss, - 34,MP-ID Absender,SG2,NAD,,00020,,,,Muss, - 35,MP-ID Absender,SG2,NAD,3035,00020,MS,,Dokumenten-/Nachrichtenausstellerbzw. -absender,X, - 36,MP-ID Absender,SG2,NAD,3039,00020,,,MP-ID,X [61],[61] MP-ID nur aus Sparte Strom - 37,MP-ID Absender,SG2,NAD,3055,00020,9,,GS1,X, - 38,MP-ID Absender,SG2,NAD,3055,,293,,"DE, BDEW(Bundesverband derEnergie- undWasserwirtschaft e.V.)",X, - 39,Ansprechpartner,SG5,,,,,,,Kann, - 40,Ansprechpartner,SG5,CTA,,00021,,,,Muss, - 41,Ansprechpartner,SG5,CTA,3139,00021,IC,,Informationskontakt,X, - 42,Ansprechpartner,SG5,CTA,3412,00021,,,Kontakt,X, - 43,Kommunikationsverbindung,SG5,COM,,00022,,,,Muss, - 44,Kommunikationsverbindung,SG5,COM,3148,00022,,,"Kommunikationsadresse,Identifikation",X, - 45,Kommunikationsverbindung,SG5,COM,3155,00022,EM,,Elektronische Post,X [1P0..1], - 46,Kommunikationsverbindung,SG5,COM,3155,,FX,,Telefax,X [1P0..1], - 47,Kommunikationsverbindung,SG5,COM,3155,,TE,,Telefon,X [1P0..1], - 48,Kommunikationsverbindung,SG5,COM,3155,,AJ,,weiteres Telefon,X [1P0..1], - 49,Kommunikationsverbindung,SG5,COM,3155,,AL,,Handy,X [1P0..1], - 50,MP-ID Empfänger,SG2,,,,,,,Muss, - 51,MP-ID Empfänger,SG2,NAD,,00023,,,,Muss, - 52,MP-ID Empfänger,SG2,NAD,3035,00023,MR,,Nachrichtenempfänger,X, - 53,MP-ID Empfänger,SG2,NAD,3039,00023,,,MP-ID,X [61],[61] MP-ID nur aus Sparte Strom - 54,MP-ID Empfänger,SG2,NAD,3055,00023,9,,GS1,X, - 55,MP-ID Empfänger,SG2,NAD,3055,,293,,"DE, BDEW(Bundesverband derEnergie- undWasserwirtschaft e.V.)",X, - 56,Positionsdaten,SG29,,,,,,,Muss [2050],[2050] Pro Nachricht ist die SG29 genau einmal anzugeben - 57,Positionsdaten,SG29,LIN,,00040,,,,Muss, - 58,Positionsdaten,SG29,LIN,1082,00040,,,Positionsnummer,X [903],[903] Format: Möglicher Wert: 1 - 59,Versionsangabe der Summenzeitreihe,SG34,,,,,,,Muss [1],[1] Wenn IMD+Z03 vorhanden - 60,Versionsangabe der Summenzeitreihe,SG34,RFF,,00060,,,,Muss, - 61,Versionsangabe der Summenzeitreihe,SG34,RFF,1153,00060,AUU,,Referenz auf eineZeitreihe,X, - 62,Versionsangabe der Summenzeitreihe,SG34,RFF,1154,00060,,,Version,X, - 63,Meldepunkt,SG38,,,,,,,Muss, - 64,Meldepunkt,SG38,LOC,,00063,,,,Muss, - 65,Meldepunkt,SG38,LOC,3227,00063,172,,Meldepunkt,X, - 66,Meldepunkt,SG38,LOC,3225,00063,,,Meldepunkt,X [951][527],"[501] Hinweis: Zählpunkt der DZR - [527] Hinweis: Zählpunkt der BG-SZR (Kategorie B) - [951] Format: Zählpunktbezeichnung" - 67,Bilanzkreis für Strom,SG38,,,,,,,, - 68,Bilanzkreis für Strom,SG38,LOC,,00064,,,,, - 69,Bilanzkreis für Strom,SG38,LOC,3227,00064,237,,Bilanzkreis,, - 70,Bilanzkreis für Strom,SG38,LOC,3225,00064,,,Bilanzkreis,, - 71,Abschnitts-Kontrollsegment,,UNS,,00123,,,,Muss, - 72,Abschnitts-Kontrollsegment,,UNS,0081,00123,S,,Trennung von Positions-und Summenteil,X, - 73,Nachrichten-Endesegment,,UNT,,00125,,,,Muss, - 74,Nachrichten-Endesegment,,UNT,0074,00125,,,Anzahl der Segmente in einerNachricht,X, - 75,Nachrichten-Endesegment,,UNT,0062,00125,,,Nachrichten-Referenznummer,X, - - ''', - '17207.csv': ''' - ,Segmentname,Segmentgruppe,Segment,Datenelement,Segment ID,Code,Qualifier,Beschreibung,Bedingungsausdruck,Bedingung - 0,Nachrichten-Kopfsegment,,UNH,,00001,,,,Muss, - 1,Nachrichten-Kopfsegment,,UNH,0062,00001,,,Nachrichten-Referenznummer,X, - 2,Nachrichten-Kopfsegment,,UNH,0065,00001,ORDERS,,Bestellung,X, - 3,Nachrichten-Kopfsegment,,UNH,0052,00001,D,,Entwurfs-Version,X, - 4,Nachrichten-Kopfsegment,,UNH,0054,00001,09B,,Ausgabe 2009 - B,X, - 5,Nachrichten-Kopfsegment,,UNH,0051,00001,UN,,UN/CEFACT,X, - 6,Nachrichten-Kopfsegment,,UNH,0057,00001,1.3,,Versionsnummer derzugrundeliegendenBDEW-Nachrichtenbeschreibung,X, - 7,Beginn der Nachricht,,BGM,,00002,,,,Muss, - 8,Beginn der Nachricht,,BGM,1001,00002,Z05,,Clearingliste,, - 9,Beginn der Nachricht,,BGM,1001,,BK,,Zeitreihen im RahmenderBilanzkreisabrechnung,X, - 10,Beginn der Nachricht,,BGM,1004,00002,,,Dokumentennummer,X, - 11,Nachrichtendatum,,DTM,,00003,,,,Muss, - 12,Nachrichtendatum,,DTM,2005,00003,137,,Dokumenten-/Nachrichtendatum/-zeit,X, - 13,Nachrichtendatum,,DTM,2380,00003,,,"Datum oder Uhrzeit oderZeitspanne, Wert",X [931][494],"[494] Das hier genannte Datum muss der Zeitpunkt sein, zu dem das Dokument erstellt wurde, oder ein Zeitpunkt, der davor liegt. - [931] Format: ZZZ = +00" - 14,Nachrichtendatum,,DTM,2379,00003,303,,CCYYMMDDHHMMZZZ,X, - 15,Ausführungsdatum,,DTM,,00004,,,,Muss,"[33] Wenn IMD+Z01 vorhanden - [34] Wenn IMD+Z02 vorhanden" - 16,Ausführungsdatum,,DTM,2005,00004,203,,Ausführungsdatum/-zeit,X, - 17,Ausführungsdatum,,DTM,2380,00004,,,"Datum oder Uhrzeit oderZeitspanne, Wert",X [UB1], - 18,Ausführungsdatum,,DTM,2379,00004,303,,CCYYMMDDHHMMZZZ,X, - 19,Betrachtungszeitintervall,,DTM,,00006,,,,,[1] Wenn IMD+Z03 vorhanden - 20,Betrachtungszeitintervall,,DTM,2005,00006,273,,Gültigkeitszeitspanne,, - 21,Betrachtungszeitintervall,,DTM,2380,00006,,,"Datum oder Uhrzeit oderZeitspanne, Wert",, - 22,Betrachtungszeitintervall,,DTM,2379,00006,610,,CCYYMM,, - 23,Abonnement,,IMD,,00008,,,,Muss, - 24,Abonnement,,IMD,7081,00008,Z01,,Start Abo,X, - 25,Abonnement,,IMD,7081,,Z02,,Ende Abo,X, - 26,Abonnement,,IMD,7081,,Z03,,ohne Abo,, - 27,Prüfidentifikator,SG1,,,,,,,Muss, - 28,Prüfidentifikator,SG1,RFF,,00019,,,,Muss, - 29,Prüfidentifikator,SG1,RFF,1153,00019,Z13,,Prüfidentifikator,X, - 30,Prüfidentifikator,SG1,RFF,1154,00019,17206,,AnforderungBilanzierungsgebietsclearingliste,, - 31,Prüfidentifikator,SG1,RFF,1154,,17207,,Ab-/Bestellung BK-SZRauf AggregationsebeneRZ,X, - 32,Prüfidentifikator,SG1,RFF,1154,,17208,,AnforderungClearingliste ÜNB-DZR,, - 33,MP-ID Absender,SG2,,,,,,,Muss, - 34,MP-ID Absender,SG2,NAD,,00020,,,,Muss, - 35,MP-ID Absender,SG2,NAD,3035,00020,MS,,Dokumenten-/Nachrichtenausstellerbzw. -absender,X, - 36,MP-ID Absender,SG2,NAD,3039,00020,,,MP-ID,X [61],[61] MP-ID nur aus Sparte Strom - 37,MP-ID Absender,SG2,NAD,3055,00020,9,,GS1,X, - 38,MP-ID Absender,SG2,NAD,3055,,293,,"DE, BDEW(Bundesverband derEnergie- undWasserwirtschaft e.V.)",X, - 39,Ansprechpartner,SG5,,,,,,,Kann, - 40,Ansprechpartner,SG5,CTA,,00021,,,,Muss, - 41,Ansprechpartner,SG5,CTA,3139,00021,IC,,Informationskontakt,X, - 42,Ansprechpartner,SG5,CTA,3412,00021,,,Kontakt,X, - 43,Kommunikationsverbindung,SG5,COM,,00022,,,,Muss, - 44,Kommunikationsverbindung,SG5,COM,3148,00022,,,"Kommunikationsadresse,Identifikation",X, - 45,Kommunikationsverbindung,SG5,COM,3155,00022,EM,,Elektronische Post,X [1P0..1], - 46,Kommunikationsverbindung,SG5,COM,3155,,FX,,Telefax,X [1P0..1], - 47,Kommunikationsverbindung,SG5,COM,3155,,TE,,Telefon,X [1P0..1], - 48,Kommunikationsverbindung,SG5,COM,3155,,AJ,,weiteres Telefon,X [1P0..1], - 49,Kommunikationsverbindung,SG5,COM,3155,,AL,,Handy,X [1P0..1], - 50,MP-ID Empfänger,SG2,,,,,,,Muss, - 51,MP-ID Empfänger,SG2,NAD,,00023,,,,Muss, - 52,MP-ID Empfänger,SG2,NAD,3035,00023,MR,,Nachrichtenempfänger,X, - 53,MP-ID Empfänger,SG2,NAD,3039,00023,,,MP-ID,X [61],[61] MP-ID nur aus Sparte Strom - 54,MP-ID Empfänger,SG2,NAD,3055,00023,9,,GS1,X, - 55,MP-ID Empfänger,SG2,NAD,3055,,293,,"DE, BDEW(Bundesverband derEnergie- undWasserwirtschaft e.V.)",X, - 56,Positionsdaten,SG29,,,,,,,Muss [2050],[2050] Pro Nachricht ist die SG29 genau einmal anzugeben - 57,Positionsdaten,SG29,LIN,,00040,,,,Muss, - 58,Positionsdaten,SG29,LIN,1082,00040,,,Positionsnummer,X [903],[903] Format: Möglicher Wert: 1 - 59,Versionsangabe der Summenzeitreihe,SG34,,,,,,,,[1] Wenn IMD+Z03 vorhanden - 60,Versionsangabe der Summenzeitreihe,SG34,RFF,,00060,,,,, - 61,Versionsangabe der Summenzeitreihe,SG34,RFF,1153,00060,AUU,,Referenz auf eineZeitreihe,, - 62,Versionsangabe der Summenzeitreihe,SG34,RFF,1154,00060,,,Version,, - 63,Meldepunkt,SG38,,,,,,,, - 64,Meldepunkt,SG38,LOC,,00063,,,,, - 65,Meldepunkt,SG38,LOC,3227,00063,172,,Meldepunkt,, - 66,Meldepunkt,SG38,LOC,3225,00063,,,Meldepunkt,,"[501] Hinweis: Zählpunkt der DZR - [527] Hinweis: Zählpunkt der BG-SZR (Kategorie B) - [951] Format: Zählpunktbezeichnung" - 67,Bilanzkreis für Strom,SG38,,,,,,,Muss, - 68,Bilanzkreis für Strom,SG38,LOC,,00064,,,,Muss, - 69,Bilanzkreis für Strom,SG38,LOC,3227,00064,237,,Bilanzkreis,X, - 70,Bilanzkreis für Strom,SG38,LOC,3225,00064,,,Bilanzkreis,X, - 71,Abschnitts-Kontrollsegment,,UNS,,00123,,,,Muss, - 72,Abschnitts-Kontrollsegment,,UNS,0081,00123,S,,Trennung von Positions-und Summenteil,X, - 73,Nachrichten-Endesegment,,UNT,,00125,,,,Muss, - 74,Nachrichten-Endesegment,,UNT,0074,00125,,,Anzahl der Segmente in einerNachricht,X, - 75,Nachrichten-Endesegment,,UNT,0062,00125,,,Nachrichten-Referenznummer,X, - - ''', - '17208.csv': ''' - ,Segmentname,Segmentgruppe,Segment,Datenelement,Segment ID,Code,Qualifier,Beschreibung,Bedingungsausdruck,Bedingung - 0,Nachrichten-Kopfsegment,,UNH,,00001,,,,Muss, - 1,Nachrichten-Kopfsegment,,UNH,0062,00001,,,Nachrichten-Referenznummer,X, - 2,Nachrichten-Kopfsegment,,UNH,0065,00001,ORDERS,,Bestellung,X, - 3,Nachrichten-Kopfsegment,,UNH,0052,00001,D,,Entwurfs-Version,X, - 4,Nachrichten-Kopfsegment,,UNH,0054,00001,09B,,Ausgabe 2009 - B,X, - 5,Nachrichten-Kopfsegment,,UNH,0051,00001,UN,,UN/CEFACT,X, - 6,Nachrichten-Kopfsegment,,UNH,0057,00001,1.3,,Versionsnummer derzugrundeliegendenBDEW-Nachrichtenbeschreibung,X, - 7,Beginn der Nachricht,,BGM,,00002,,,,Muss, - 8,Beginn der Nachricht,,BGM,1001,00002,Z05,,Clearingliste,X, - 9,Beginn der Nachricht,,BGM,1001,,BK,,Zeitreihen im RahmenderBilanzkreisabrechnung,, - 10,Beginn der Nachricht,,BGM,1004,00002,,,Dokumentennummer,X, - 11,Nachrichtendatum,,DTM,,00003,,,,Muss, - 12,Nachrichtendatum,,DTM,2005,00003,137,,Dokumenten-/Nachrichtendatum/-zeit,X, - 13,Nachrichtendatum,,DTM,2380,00003,,,"Datum oder Uhrzeit oderZeitspanne, Wert",X [931][494],"[494] Das hier genannte Datum muss der Zeitpunkt sein, zu dem das Dokument erstellt wurde, oder ein Zeitpunkt, der davor liegt. - [931] Format: ZZZ = +00" - 14,Nachrichtendatum,,DTM,2379,00003,303,,CCYYMMDDHHMMZZZ,X, - 15,Ausführungsdatum,,DTM,,00004,,,,,"[33] Wenn IMD+Z01 vorhanden - [34] Wenn IMD+Z02 vorhanden" - 16,Ausführungsdatum,,DTM,2005,00004,203,,Ausführungsdatum/-zeit,, - 17,Ausführungsdatum,,DTM,2380,00004,,,"Datum oder Uhrzeit oderZeitspanne, Wert",, - 18,Ausführungsdatum,,DTM,2379,00004,303,,CCYYMMDDHHMMZZZ,, - 19,Betrachtungszeitintervall,,DTM,,00006,,,,Muss,[1] Wenn IMD+Z03 vorhanden - 20,Betrachtungszeitintervall,,DTM,2005,00006,273,,Gültigkeitszeitspanne,X, - 21,Betrachtungszeitintervall,,DTM,2380,00006,,,"Datum oder Uhrzeit oderZeitspanne, Wert",X, - 22,Betrachtungszeitintervall,,DTM,2379,00006,610,,CCYYMM,X, - 23,Abonnement,,IMD,,00008,,,,Muss, - 24,Abonnement,,IMD,7081,00008,Z01,,Start Abo,, - 25,Abonnement,,IMD,7081,,Z02,,Ende Abo,, - 26,Abonnement,,IMD,7081,,Z03,,ohne Abo,X, - 27,Prüfidentifikator,SG1,,,,,,,Muss, - 28,Prüfidentifikator,SG1,RFF,,00019,,,,Muss, - 29,Prüfidentifikator,SG1,RFF,1153,00019,Z13,,Prüfidentifikator,X, - 30,Prüfidentifikator,SG1,RFF,1154,00019,17206,,AnforderungBilanzierungsgebietsclearingliste,, - 31,Prüfidentifikator,SG1,RFF,1154,,17207,,Ab-/Bestellung BK-SZRauf AggregationsebeneRZ,, - 32,Prüfidentifikator,SG1,RFF,1154,,17208,,AnforderungClearingliste ÜNB-DZR,X, - 33,MP-ID Absender,SG2,,,,,,,Muss, - 34,MP-ID Absender,SG2,NAD,,00020,,,,Muss, - 35,MP-ID Absender,SG2,NAD,3035,00020,MS,,Dokumenten-/Nachrichtenausstellerbzw. -absender,X, - 36,MP-ID Absender,SG2,NAD,3039,00020,,,MP-ID,X [61],[61] MP-ID nur aus Sparte Strom - 37,MP-ID Absender,SG2,NAD,3055,00020,9,,GS1,X, - 38,MP-ID Absender,SG2,NAD,3055,,293,,"DE, BDEW(Bundesverband derEnergie- undWasserwirtschaft e.V.)",X, - 39,Ansprechpartner,SG5,,,,,,,Kann, - 40,Ansprechpartner,SG5,CTA,,00021,,,,Muss, - 41,Ansprechpartner,SG5,CTA,3139,00021,IC,,Informationskontakt,X, - 42,Ansprechpartner,SG5,CTA,3412,00021,,,Kontakt,X, - 43,Kommunikationsverbindung,SG5,COM,,00022,,,,Muss, - 44,Kommunikationsverbindung,SG5,COM,3148,00022,,,"Kommunikationsadresse,Identifikation",X, - 45,Kommunikationsverbindung,SG5,COM,3155,00022,EM,,Elektronische Post,X [1P0..1], - 46,Kommunikationsverbindung,SG5,COM,3155,,FX,,Telefax,X [1P0..1], - 47,Kommunikationsverbindung,SG5,COM,3155,,TE,,Telefon,X [1P0..1], - 48,Kommunikationsverbindung,SG5,COM,3155,,AJ,,weiteres Telefon,X [1P0..1], - 49,Kommunikationsverbindung,SG5,COM,3155,,AL,,Handy,X [1P0..1], - 50,MP-ID Empfänger,SG2,,,,,,,Muss, - 51,MP-ID Empfänger,SG2,NAD,,00023,,,,Muss, - 52,MP-ID Empfänger,SG2,NAD,3035,00023,MR,,Nachrichtenempfänger,X, - 53,MP-ID Empfänger,SG2,NAD,3039,00023,,,MP-ID,X [61],[61] MP-ID nur aus Sparte Strom - 54,MP-ID Empfänger,SG2,NAD,3055,00023,9,,GS1,X, - 55,MP-ID Empfänger,SG2,NAD,3055,,293,,"DE, BDEW(Bundesverband derEnergie- undWasserwirtschaft e.V.)",X, - 56,Positionsdaten,SG29,,,,,,,Muss [2050],[2050] Pro Nachricht ist die SG29 genau einmal anzugeben - 57,Positionsdaten,SG29,LIN,,00040,,,,Muss, - 58,Positionsdaten,SG29,LIN,1082,00040,,,Positionsnummer,X [903],[903] Format: Möglicher Wert: 1 - 59,Versionsangabe der Summenzeitreihe,SG34,,,,,,,Muss,[1] Wenn IMD+Z03 vorhanden - 60,Versionsangabe der Summenzeitreihe,SG34,RFF,,00060,,,,Muss, - 61,Versionsangabe der Summenzeitreihe,SG34,RFF,1153,00060,AUU,,Referenz auf eineZeitreihe,X, - 62,Versionsangabe der Summenzeitreihe,SG34,RFF,1154,00060,,,Version,X, - 63,Meldepunkt,SG38,,,,,,,Muss, - 64,Meldepunkt,SG38,LOC,,00063,,,,Muss, - 65,Meldepunkt,SG38,LOC,3227,00063,172,,Meldepunkt,X, - 66,Meldepunkt,SG38,LOC,3225,00063,,,Meldepunkt,X [951][501],"[501] Hinweis: Zählpunkt der DZR - [527] Hinweis: Zählpunkt der BG-SZR (Kategorie B) - [951] Format: Zählpunktbezeichnung" - 67,Bilanzkreis für Strom,SG38,,,,,,,, - 68,Bilanzkreis für Strom,SG38,LOC,,00064,,,,, - 69,Bilanzkreis für Strom,SG38,LOC,3227,00064,237,,Bilanzkreis,, - 70,Bilanzkreis für Strom,SG38,LOC,3225,00064,,,Bilanzkreis,, - 71,Abschnitts-Kontrollsegment,,UNS,,00123,,,,Muss, - 72,Abschnitts-Kontrollsegment,,UNS,0081,00123,S,,Trennung von Positions-und Summenteil,X, - 73,Nachrichten-Endesegment,,UNT,,00125,,,,Muss, - 74,Nachrichten-Endesegment,,UNT,0074,00125,,,Anzahl der Segmente in einerNachricht,X, - 75,Nachrichten-Endesegment,,UNT,0062,00125,,,Nachrichten-Referenznummer,X, - - ''', - '17209.csv': ''' - ,Segmentname,Segmentgruppe,Segment,Datenelement,Segment ID,Code,Qualifier,Beschreibung,Bedingungsausdruck,Bedingung - 0,Nachrichten-Kopfsegment,,UNH,,00001,,,,Muss, - 1,Nachrichten-Kopfsegment,,UNH,0062,00001,,,Nachrichten-Referenznummer,X, - 2,Nachrichten-Kopfsegment,,UNH,0065,00001,ORDERS,,Bestellung,X, - 3,Nachrichten-Kopfsegment,,UNH,0052,00001,D,,Entwurfs-Version,X, - 4,Nachrichten-Kopfsegment,,UNH,0054,00001,09B,,Ausgabe 2009 - B,X, - 5,Nachrichten-Kopfsegment,,UNH,0051,00001,UN,,UN/CEFACT,X, - 6,Nachrichten-Kopfsegment,,UNH,0057,00001,1.3,,Versionsnummer derzugrundeliegendenBDEW-Nachrichtenbeschreibung,X, - 7,Beginn der Nachricht,,BGM,,00002,,,,Muss, - 8,Beginn der Nachricht,,BGM,1001,00002,Z45,,Redispatch EinzelzeitreiheAusfallarbeit,X, - 9,Beginn der Nachricht,,BGM,1004,00002,,,Dokumentennummer,X, - 10,Nachrichtendatum,,DTM,,00003,,,,Muss, - 11,Nachrichtendatum,,DTM,2005,00003,137,,Dokumenten-/Nachrichtendatum/-zeit,X, - 12,Nachrichtendatum,,DTM,2380,00003,,,"Datum oder Uhrzeit oderZeitspanne, Wert",X [931] [494],"[494] Das hier genannte Datum muss der Zeitpunkt sein, zu dem das Dokument erstellt wurde, oder ein Zeitpunkt, der davor liegt. - [931] Format: ZZZ = +00" - 13,Nachrichtendatum,,DTM,2379,00003,303,,CCYYMMDDHHMMZZZ,X, - 14,ID der Redispatch- Maßnahme,SG1,,,,,,,Muss, - 15,ID der Redispatch- Maßnahme,SG1,RFF,,00015,,,,Muss, - 16,ID der Redispatch- Maßnahme,SG1,RFF,1153,00015,AGK,,Anwendungsreferenznummer,X, - 17,ID der Redispatch- Maßnahme,SG1,RFF,1154,00015,,,ID der RD-Maßnahme,X, - 18,Prüfidentifikator,SG1,,,,,,,Muss, - 19,Prüfidentifikator,SG1,RFF,,00019,,,,Muss, - 20,Prüfidentifikator,SG1,RFF,1153,00019,Z13,,Prüfidentifikator,X, - 21,Prüfidentifikator,SG1,RFF,1154,00019,17209,,Anforderung Ausfallarbeit,X, - 22,MP-ID Absender,SG2,,,,,,,Muss, - 23,MP-ID Absender,SG2,NAD,,00020,,,,Muss, - 24,MP-ID Absender,SG2,NAD,3035,00020,Nachrichtenaussteller bzw.-absender,,,MS, - 25,MP-ID Absender,SG2,NAD,3039,00020,,,MP-ID,X [61],[61] MP-ID nur aus Sparte Strom - 26,MP-ID Absender,SG2,NAD,3055,00020,9,,GS1,X, - 27,MP-ID Absender,SG2,NAD,3055,,293,,"DE, BDEW (Bundesverbandder Energie- undWasserwirtschaft e.V.)",X, - 28,Ansprechpartner,SG5,,,,,,,Kann, - 29,Ansprechpartner,SG5,CTA,,00021,,,,Muss, - 30,Ansprechpartner,SG5,CTA,3139,00021,,,,IC, - 31,Ansprechpartner,SG5,CTA,3412,00021,,,Kontakt,X, - 32,Kommunikationsverbindung,SG5,COM,,00022,,,,Muss, - 33,Kommunikationsverbindung,SG5,COM,3148,00022,,,"Kommunikationsadresse,Identifikation",X, - 34,Kommunikationsverbindung,SG5,COM,3155,00022,EM,,Elektronische Post,X [1P0..1], - 35,Kommunikationsverbindung,SG5,COM,3155,,FX,,Telefax,X [1P0..1], - 36,Kommunikationsverbindung,SG5,COM,3155,,TE,,Telefon,X [1P0..1], - 37,Kommunikationsverbindung,SG5,COM,3155,,AJ,,weiteres Telefon,X [1P0..1], - 38,Kommunikationsverbindung,SG5,COM,3155,,AL,,Handy,X [1P0..1], - 39,MP-ID Empfänger,SG2,,,,,,,Muss, - 40,MP-ID Empfänger,SG2,NAD,,00023,,,,Muss, - 41,MP-ID Empfänger,SG2,NAD,3035,00023,,,,MR, - 42,MP-ID Empfänger,SG2,NAD,3039,00023,,,MP-ID,X [61],[61] MP-ID nur aus Sparte Strom - 43,MP-ID Empfänger,SG2,NAD,3055,00023,9,,GS1,X, - 44,MP-ID Empfänger,SG2,NAD,3055,,293,,"DE, BDEW (Bundesverbandder Energie- undWasserwirtschaft e.V.)",X, - 45,Meldepunkt,SG2,,,,,,,Muss, - 46,Meldepunkt,SG2,NAD,,00025,,,,Muss, - 47,Meldepunkt,SG2,NAD,3035,00025,,,,DP, - 48,Meldepunkt,SG2,LOC,,00026,,,,Muss, - 49,Meldepunkt,SG2,LOC,3227,00026,,,,172, - 50,Meldepunkt,SG2,LOC,3225,00026,,,Identifikator,X [922],[922] Format: TR-ID - 51,Positionsdaten,SG29,,,,,,,Muss [2050],[2050] Pro Nachricht ist die SG29 genau einmal anzugeben - 52,Positionsdaten,SG29,LIN,,00040,,,,Muss, - 53,Positionsdaten,SG29,LIN,1082,00040,,,Positionsnummer,X [903],[903] Format: Möglicher Wert: 1 - 54,Beginn Zeitraum für Wertanfrage,SG29,DTM,,00045,,,,Muss, - 55,Beginn Zeitraum für Wertanfrage,SG29,DTM,2005,00045,163,,"Verarbeitung,Beginndatum/-zeit",X, - 56,Beginn Zeitraum für Wertanfrage,SG29,DTM,2380,00045,,,"Datum oder Uhrzeit oderZeitspanne, Wert",X [931],[931] Format: ZZZ = +00 - 57,Beginn Zeitraum für Wertanfrage,SG29,DTM,2379,00045,303,,CCYYMMDDHHMMZZZ,X, - 58,Ende Zeitraum für Wertanfrage,SG29,DTM,,00046,,,,Muss, - 59,Ende Zeitraum für Wertanfrage,SG29,DTM,2005,00046,164,,"Verarbeitung,Endedatum/-zeit",X, - 60,Ende Zeitraum für Wertanfrage,SG29,DTM,2380,00046,,,"Datum oder Uhrzeit oderZeitspanne, Wert",X [931],[931] Format: ZZZ = +00 - 61,Ende Zeitraum für Wertanfrage,SG29,DTM,2379,00046,303,,CCYYMMDDHHMMZZZ,X, - 62,Abschnitts-Kontrollsegment,,UNS,,00123,,,,Muss, - 63,Abschnitts-Kontrollsegment,,UNS,0081,00123,und Summenteil,,,S, - 64,Nachrichten-Endesegment,,UNT,,00125,,,,Muss, - 65,Nachrichten-Endesegment,,UNT,0074,00125,,,Anzahl der Segmente in einerNachricht,X, - 66,Nachrichten-Endesegment,,UNT,0062,00125,,,Nachrichten-Referenznummer,X, - - ''', - '17210.csv': ''' - ,Segmentname,Segmentgruppe,Segment,Datenelement,Segment ID,Code,Qualifier,Beschreibung,Bedingungsausdruck,Bedingung - 0,Nachrichten-Kopfsegment,,UNH,,00001,,,,Muss, - 1,Nachrichten-Kopfsegment,,UNH,0062,00001,,,Nachrichten-Referenznummer,X, - 2,Nachrichten-Kopfsegment,,UNH,0065,00001,ORDERS,,Bestellung,X, - 3,Nachrichten-Kopfsegment,,UNH,0052,00001,D,,Entwurfs-Version,X, - 4,Nachrichten-Kopfsegment,,UNH,0054,00001,09B,,Ausgabe 2009 - B,X, - 5,Nachrichten-Kopfsegment,,UNH,0051,00001,UN,,UN/CEFACT,X, - 6,Nachrichten-Kopfsegment,,UNH,0057,00001,1.3,,Versionsnummer derzugrundeliegendenBDEW-Nachrichtenbeschreibung,X, - 7,Beginn der Nachricht,,BGM,,00002,,,,Muss, - 8,Beginn der Nachricht,,BGM,1001,00002,Z05,,Clearingliste,X, - 9,Beginn der Nachricht,,BGM,1004,00002,,,Dokumentennummer,X, - 10,Nachrichtendatum,,DTM,,00003,,,,Muss, - 11,Nachrichtendatum,,DTM,2005,00003,137,,Dokumenten-/Nachrichtendatum/-zeit,X, - 12,Nachrichtendatum,,DTM,2380,00003,,,"Datum oder Uhrzeit oderZeitspanne, Wert",X [931] [494],"[494] Das hier genannte Datum muss der Zeitpunkt sein, zu dem das Dokument erstellt wurde, oder ein Zeitpunkt, der davor liegt. - [931] Format: ZZZ = +00" - 13,Nachrichtendatum,,DTM,2379,00003,303,,CCYYMMDDHHMMZZZ,X, - 14,Ausführungsdatum,,DTM,,00004,,,,Muss [33] ⊻ [34],"[33] Wenn IMD+Z01 vorhanden - [34] Wenn IMD+Z02 vorhanden" - 15,Ausführungsdatum,,DTM,2005,00004,203,,Ausführungsdatum/-zeit,X, - 16,Ausführungsdatum,,DTM,2380,00004,,,"Datum oder Uhrzeit oderZeitspanne, Wert",X [UB1], - 17,Ausführungsdatum,,DTM,2379,00004,303,,CCYYMMDDHHMMZZZ,X, - 18,Betrachtungszeitintervall,,DTM,,00006,,,,Muss [1],[1] Wenn IMD+Z03 vorhanden - 19,Betrachtungszeitintervall,,DTM,2005,00006,273,,Gültigkeitszeitspanne,X, - 20,Betrachtungszeitintervall,,DTM,2380,00006,,,"Datum oder Uhrzeit oderZeitspanne, Wert",X, - 21,Betrachtungszeitintervall,,DTM,2379,00006,610,,CCYYMM,X, - 22,Abonnement,,IMD,,00008,,,,Muss, - 23,Abonnement,,IMD,7081,00008,Z01,,Start Abo,X, - 24,Abonnement,,IMD,7081,,Z02,,Ende Abo,X, - 25,Abonnement,,IMD,7081,,Z03,,ohne Abo,X, - 26,Prüfidentifikator,SG1,,,,,,,Muss, - 27,Prüfidentifikator,SG1,RFF,,00019,,,,Muss, - 28,Prüfidentifikator,SG1,RFF,1153,00019,Z13,,Prüfidentifikator,X, - 29,Prüfidentifikator,SG1,RFF,1154,00019,17210,,Anforderung,X, - 30,MP-ID Absender,SG2,,,,,,,Muss, - 31,MP-ID Absender,SG2,NAD,,00020,,,,Muss, - 32,MP-ID Absender,SG2,NAD,3035,00020,Nachrichtenaussteller bzw.-absender,,,MS, - 33,MP-ID Absender,SG2,NAD,3039,00020,,,MP-ID,X [61],[61] MP-ID nur aus Sparte Strom - 34,MP-ID Absender,SG2,NAD,3055,00020,9,,GS1,X, - 35,MP-ID Absender,SG2,NAD,3055,,293,,"DE, BDEW (Bundesverbandder Energie- undWasserwirtschaft e.V.)",X, - 36,Ansprechpartner,SG5,,,,,,,Kann, - 37,Ansprechpartner,SG5,CTA,,00021,,,,Muss, - 38,Ansprechpartner,SG5,CTA,3139,00021,,,,IC, - 39,Ansprechpartner,SG5,CTA,3412,00021,,,Kontakt,X, - 40,Kommunikationsverbindung,SG5,COM,,00022,,,,Muss, - 41,Kommunikationsverbindung,SG5,COM,3148,00022,,,"Kommunikationsadresse,Identifikation",X, - 42,Kommunikationsverbindung,SG5,COM,3155,00022,EM,,Elektronische Post,X [1P0..1], - 43,Kommunikationsverbindung,SG5,COM,3155,,FX,,Telefax,X [1P0..1], - 44,Kommunikationsverbindung,SG5,COM,3155,,TE,,Telefon,X [1P0..1], - 45,Kommunikationsverbindung,SG5,COM,3155,,AJ,,weiteres Telefon,X [1P0..1], - 46,Kommunikationsverbindung,SG5,COM,3155,,AL,,Handy,X [1P0..1], - 47,MP-ID Empfänger,SG2,,,,,,,Muss, - 48,MP-ID Empfänger,SG2,NAD,,00023,,,,Muss, - 49,MP-ID Empfänger,SG2,NAD,3035,00023,,,,MR, - 50,MP-ID Empfänger,SG2,NAD,3039,00023,,,MP-ID,X [61],[61] MP-ID nur aus Sparte Strom - 51,MP-ID Empfänger,SG2,NAD,3055,00023,9,,GS1,X, - 52,MP-ID Empfänger,SG2,NAD,3055,,293,,"DE, BDEW (Bundesverbandder Energie- undWasserwirtschaft e.V.)",X, - 53,Positionsdaten,SG29,,,,,,,Muss [2050],[2050] Pro Nachricht ist die SG29 genau einmal anzugeben - 54,Positionsdaten,SG29,LIN,,00040,,,,Muss, - 55,Positionsdaten,SG29,LIN,1082,00040,,,Positionsnummer,X [903],[903] Format: Möglicher Wert: 1 - 56,Versionsangabe der Summenzeitreihe,SG34,,,,,,,Muss [1],[1] Wenn IMD+Z03 vorhanden - 57,Versionsangabe der Summenzeitreihe,SG34,RFF,,00060,,,,Muss, - 58,Versionsangabe der Summenzeitreihe,SG34,RFF,1153,00060,AUU,,Referenz auf eine Zeitreihe,X, - 59,Versionsangabe der Summenzeitreihe,SG34,RFF,1154,00060,,,Version,X, - 60,Meldepunkt,SG38,,,,,,,Muss, - 61,Meldepunkt,SG38,LOC,,00063,,,,Muss, - 62,Meldepunkt,SG38,LOC,3227,00063,,,,172, - 63,Meldepunkt,SG38,LOC,3225,00063,,,Meldepunkt,X [951] [517],"[517] Hinweis: Zählpunkt der LF- AASZR - [951] Format: Zählpunktbezeichnung" - 64,Abschnitts-Kontrollsegment,,UNS,,00123,,,,Muss, - 65,Abschnitts-Kontrollsegment,,UNS,0081,00123,und Summenteil,,,S, - 66,Nachrichten-Endesegment,,UNT,,00125,,,,Muss, - 67,Nachrichten-Endesegment,,UNT,0074,00125,,,Anzahl der Segmente in einerNachricht,X, - 68,Nachrichten-Endesegment,,UNT,0062,00125,,,Nachrichten-Referenznummer,X, - - ''', - '17211.csv': ''' - ,Segmentname,Segmentgruppe,Segment,Datenelement,Segment ID,Code,Qualifier,Beschreibung,Bedingungsausdruck,Bedingung - 0,Nachrichten-Kopfsegment,,UNH,,00001,,,,Muss, - 1,Nachrichten-Kopfsegment,,UNH,0062,00001,,,Nachrichten-Referenznummer,X, - 2,Nachrichten-Kopfsegment,,UNH,0065,00001,ORDERS,,Bestellung,X, - 3,Nachrichten-Kopfsegment,,UNH,0052,00001,D,,Entwurfs-Version,X, - 4,Nachrichten-Kopfsegment,,UNH,0054,00001,09B,,Ausgabe 2009 - B,X, - 5,Nachrichten-Kopfsegment,,UNH,0051,00001,UN,,UN/CEFACT,X, - 6,Nachrichten-Kopfsegment,,UNH,0057,00001,1.3,,Versionsnummer derzugrundeliegendenBDEW-Nachrichtenbeschreibung,X, - 7,Beginn der Nachricht,,BGM,,00002,,,,Muss, - 8,Beginn der Nachricht,,BGM,1001,00002,Z58,,Reklamation Profil/Profilschar,X, - 9,Beginn der Nachricht,,BGM,1004,00002,,,Dokumentennummer,X, - 10,Nachrichtendatum,,DTM,,00003,,,,Muss, - 11,Nachrichtendatum,,DTM,2005,00003,137,,Dokumenten-/Nachrichtendatum/-zeit,X, - 12,Nachrichtendatum,,DTM,2380,00003,,,"Datum oder Uhrzeit oderZeitspanne, Wert",X [931] [494],"[494] Das hier genannte Datum muss der Zeitpunkt sein, zu dem das Dokument erstellt wurde, oder ein Zeitpunkt, der davor liegt. - [931] Format: ZZZ = +00" - 13,Nachrichtendatum,,DTM,2379,00003,303,,CCYYMMDDHHMMZZZ,X, - 14,Reklamation von normierten Profilen bzw. Profilscharen,,FTX,,00012,,,,Muss, - 15,Reklamation von normierten Profilen bzw. Profilscharen,,FTX,4451,00012,,,,AFH, - 16,Reklamation von normierten Profilen bzw. Profilscharen,,FTX,4441,00012,,,Code des Prüfschritts,X, - 17,Reklamation von normierten Profilen bzw. Profilscharen,,FTX,1131,00012,E_0100,,EBD Nr. E_0100,X [6], - 18,Reklamation von normierten Profilen bzw. Profilscharen,,FTX,1131,,E_0101,,EBD Nr. E_0101,X [26],"[6] Wenn MP-ID in SG2 NAD+MS mit Rolle LF vorhanden - [26] Wenn MP-ID in SG2 NAD+MS mit Rolle ÜNB vorhanden" - 19,Referenz Nachrichtennummer,SG1,,,,,,,Muss, - 20,Referenz Nachrichtennummer,SG1,RFF,,00013,,,,Muss, - 21,Referenz Nachrichtennummer,SG1,RFF,1153,00013,ACW,,Referenznummer einervorangegangenenNachricht,X, - 22,Referenz Nachrichtennummer,SG1,RFF,1154,00013,,,Nachrichtennummer,X [525],[525] Hinweis: Wert aus BGM DE1004 der MSCONS - 23,Prüfidentifikator,SG1,,,,,,,Muss, - 24,Prüfidentifikator,SG1,RFF,,00019,,,,Muss, - 25,Prüfidentifikator,SG1,RFF,1153,00019,Z13,,Prüfidentifikator,X, - 26,Prüfidentifikator,SG1,RFF,1154,00019,17211,,Reklamation Profile bzw.Profilscharen,X, - 27,MP-ID Absender,SG2,,,,,,,Muss, - 28,MP-ID Absender,SG2,NAD,,00020,,,,Muss, - 29,MP-ID Absender,SG2,NAD,3035,00020,Nachrichtenaussteller bzw.-absender,,,MS, - 30,MP-ID Absender,SG2,NAD,3039,00020,,,MP-ID,X [61],[61] MP-ID nur aus Sparte Strom - 31,MP-ID Absender,SG2,NAD,3055,00020,9,,GS1,X, - 32,MP-ID Absender,SG2,NAD,3055,,293,,"DE, BDEW (Bundesverbandder Energie- undWasserwirtschaft e.V.)",X, - 33,Ansprechpartner,SG5,,,,,,,Kann, - 34,Ansprechpartner,SG5,CTA,,00021,,,,Muss, - 35,Ansprechpartner,SG5,CTA,3139,00021,,,,IC, - 36,Ansprechpartner,SG5,CTA,3412,00021,,,Kontakt,X, - 37,Kommunikationsverbindung,SG5,COM,,00022,,,,Muss, - 38,Kommunikationsverbindung,SG5,COM,3148,00022,,,"Kommunikationsadresse,Identifikation",X, - 39,Kommunikationsverbindung,SG5,COM,3155,00022,EM,,Elektronische Post,X [1P0..1], - 40,Kommunikationsverbindung,SG5,COM,3155,,FX,,Telefax,X [1P0..1], - 41,Kommunikationsverbindung,SG5,COM,3155,,TE,,Telefon,X [1P0..1], - 42,Kommunikationsverbindung,SG5,COM,3155,,AJ,,weiteres Telefon,X [1P0..1], - 43,Kommunikationsverbindung,SG5,COM,3155,,AL,,Handy,X [1P0..1], - 44,MP-ID Empfänger,SG2,,,,,,,Muss, - 45,MP-ID Empfänger,SG2,NAD,,00023,,,,Muss, - 46,MP-ID Empfänger,SG2,NAD,3035,00023,,,,MR, - 47,MP-ID Empfänger,SG2,NAD,3039,00023,,,MP-ID,X [61],[61] MP-ID nur aus Sparte Strom - 48,MP-ID Empfänger,SG2,NAD,3055,00023,9,,GS1,X, - 49,MP-ID Empfänger,SG2,NAD,3055,,293,,"DE, BDEW (Bundesverbandder Energie- undWasserwirtschaft e.V.)",X, - 50,Abschnitts-Kontrollsegment,,UNS,,00123,,,,Muss, - 51,Abschnitts-Kontrollsegment,,UNS,0081,00123,und Summenteil,,,S, - 52,Nachrichten-Endesegment,,UNT,,00125,,,,Muss, - 53,Nachrichten-Endesegment,,UNT,0074,00125,,,Anzahl der Segmente in einerNachricht,X, - 54,Nachrichten-Endesegment,,UNT,0062,00125,,,Nachrichten-Referenznummer,X, - - ''', - '19204.csv': ''' - ,Segmentname,Segmentgruppe,Segment,Datenelement,Segment ID,Code,Qualifier,Beschreibung,Bedingungsausdruck,Bedingung - 0,Nachrichten-Kopfsegment,,UNH,,00001,,,,Muss, - 1,Nachrichten-Kopfsegment,,UNH,0062,00001,,,Nachrichten-Referenznummer,X, - 2,Nachrichten-Kopfsegment,,UNH,0065,00001,ORDRSP,,Bestellantwort,X, - 3,Nachrichten-Kopfsegment,,UNH,0052,00001,D,,Entwurfs-Version,X, - 4,Nachrichten-Kopfsegment,,UNH,0054,00001,10A,,Ausgabe 2010 - A,X, - 5,Nachrichten-Kopfsegment,,UNH,0051,00001,UN,,UN/CEFACT,X, - 6,Nachrichten-Kopfsegment,,UNH,0057,00001,1.3,,Versionsnummer derzugrundeliegendenBDEW-Nachrichtenbeschreibung,X, - 7,Beginn der Nachricht,,BGM,,00002,,,,Muss, - 8,Beginn der Nachricht,,BGM,1001,00002,BK,,Zeitreihen im Rahmen derBilanzkreisabrechnung,X, - 9,Beginn der Nachricht,,BGM,1004,00002,,,Dokumentennummer,X, - 10,Nachrichtendatum,,DTM,,00003,,,,Muss, - 11,Nachrichtendatum,,DTM,2005,00003,137,,Dokumenten-/Nachrichtendatum/-zeit,X, - 12,Nachrichtendatum,,DTM,2380,00003,,,"Datum oder Uhrzeit oderZeitspanne, Wert",X [931] [494],"[494] Das hier genannte Datum muss der Zeitpunkt sein, zu dem das Dokument erstellt wurde, oder ein Zeitpunkt, der davor liegt. - [931] Format: ZZZ = +00" - 13,Nachrichtendatum,,DTM,2379,00003,303,,CCYYMMDDHHMMZZZ,X, - 14,Referenz Nachrichtennummer,SG1,,,,,,,Muss, - 15,Referenz Nachrichtennummer,SG1,RFF,,00009,,,,Muss, - 16,Referenz Nachrichtennummer,SG1,RFF,1153,00009,ON,,Auftragsnummer (Einkauf),X, - 17,Referenz Nachrichtennummer,SG1,RFF,1154,00009,,,Referenz Nachrichtennummer,X, - 18,Prüfidentifikator,SG1,,,,,,,Muss, - 19,Prüfidentifikator,SG1,RFF,,00012,,,,Muss, - 20,Prüfidentifikator,SG1,RFF,1153,00012,Z13,,Prüfidentifikator,X, - 21,Prüfidentifikator,SG1,RFF,1154,00012,19204,,Ablehnung Ab-/Bestellungder Aggregationsebene,X, - 22,Einzelheiten zu einer Anpassung/Änderung,SG2,,,,,,,Muss, - 23,Einzelheiten zu einer Anpassung/Änderung,SG2,AJT,,00013,,,,Muss, - 24,Einzelheiten zu einer Anpassung/Änderung,SG2,AJT,4465,00013,,,Code des Prüfschritts,X, - 25,Einzelheiten zu einer Anpassung/Änderung,SG2,AJT,1082,00013,,,,E_0003E_0022, - 26,MP-ID Absender,SG3,,,,,,,Muss, - 27,MP-ID Absender,SG3,NAD,,00015,,,,Muss, - 28,MP-ID Absender,SG3,NAD,3035,00015,Nachrichtenaussteller bzw.-absender,,,MS, - 29,MP-ID Absender,SG3,NAD,3039,00015,,,MP-ID,X [30],[30] MP-ID nur aus Sparte Strom - 30,MP-ID Absender,SG3,NAD,3055,00015,9,,GS1,X, - 31,MP-ID Absender,SG3,NAD,3055,,293,,"DE, BDEW (Bundesverbandder Energie- undWasserwirtschaft e.V.)",X, - 32,Ansprechpartner,SG6,,,,,,,Kann, - 33,Ansprechpartner,SG6,CTA,,00016,,,,Muss, - 34,Ansprechpartner,SG6,CTA,3139,00016,,,,IC, - 35,Ansprechpartner,SG6,CTA,3412,00016,,,Kontakt,X, - 36,Kommunikationsverbindung,SG6,COM,,00017,,,,Muss, - 37,Kommunikationsverbindung,SG6,COM,3148,00017,,,"Kommunikationsadresse,Identifikation",X, - 38,Kommunikationsverbindung,SG6,COM,3155,00017,EM,,Elektronische Post,X [1P0..1], - 39,Kommunikationsverbindung,SG6,COM,3155,,FX,,Telefax,X [1P0..1], - 40,Kommunikationsverbindung,SG6,COM,3155,,TE,,Telefon,X [1P0..1], - 41,Kommunikationsverbindung,SG6,COM,3155,,AJ,,weiteres Telefon,X [1P0..1], - 42,Kommunikationsverbindung,SG6,COM,3155,,AL,,Handy,X [1P0..1], - 43,MP-ID Empfänger,SG3,,,,,,,Muss, - 44,MP-ID Empfänger,SG3,NAD,,00018,,,,Muss, - 45,MP-ID Empfänger,SG3,NAD,3035,00018,,,,MR, - 46,MP-ID Empfänger,SG3,NAD,3039,00018,,,MP-ID,X [30],[30] MP-ID nur aus Sparte Strom - 47,MP-ID Empfänger,SG3,NAD,3055,00018,9,,GS1,X, - 48,MP-ID Empfänger,SG3,NAD,3055,,293,,"DE, BDEW (Bundesverbandder Energie- undWasserwirtschaft e.V.)",X, - 49,Abschnitts-Kontrollsegment,,UNS,,00030,,,,Muss, - 50,Abschnitts-Kontrollsegment,,UNS,0081,00030,und Summenteil,,,S, - 51,Nachrichten-Endesegment,,UNT,,00034,,,,Muss, - 52,Nachrichten-Endesegment,,UNT,0074,00034,,,Anzahl der Segmente in einerNachricht,X, - 53,Nachrichten-Endesegment,,UNT,0062,00034,,,Nachrichten-Referenznummer,X, - - ''', - '29001.csv': ''' - ,Segmentname,Segmentgruppe,Segment,Datenelement,Segment ID,Code,Qualifier,Beschreibung,Bedingungsausdruck,Bedingung - 0,Nachrichten-Kopfsegment,,UNH,,,,,,Muss, - 1,Nachrichten-Kopfsegment,,UNH,0062,,,,Nachrichten-Referenznummer,X, - 2,Nachrichten-Kopfsegment,,UNH,0065,,COMDIS,,Handelsunstimmigkeit,X, - 3,Nachrichten-Kopfsegment,,UNH,0052,,D,,Entwurfs-Version,X, - 4,Nachrichten-Kopfsegment,,UNH,0054,,17A,,Ausgabe 2017 - A,X, - 5,Nachrichten-Kopfsegment,,UNH,0051,,UN,,UN/CEFACT,X, - 6,Nachrichten-Kopfsegment,,UNH,0057,,1.0c,,Versionsnummer derzugrundeliegendenBDEW-Nachrichtenbeschreibung,X, - 7,Beginn der Nachricht,,BGM,,,,,,Muss, - 8,Beginn der Nachricht,,BGM,1001,,456,,Belastungsanzeige,X, - 9,Beginn der Nachricht,,BGM,1001,,739,,"MSCONS, die eineINVOIC unterstützt",, - 10,Beginn der Nachricht,,BGM,1004,,,,Dokumentennummer,X, - 11,Prüfidentifikator,,RFF,,,,,,Muss, - 12,Prüfidentifikator,,RFF,1153,,Z13,,Prüfidentifikator,X, - 13,Prüfidentifikator,,RFF,1154,,29001,,Ablehnung REMADV,X, - 14,Prüfidentifikator,,RFF,1154,,29002,,Ablehnung IFTSTA,, - 15,Dokumentendatum,,DTM,,,,,,Muss, - 16,Dokumentendatum,,DTM,2005,,137,,Dokumenten-/Nachrichtendatum/-zeit,X, - 17,Dokumentendatum,,DTM,2380,,,,"Datum oder Uhrzeit oderZeitspanne, Wert",X [931],[931] Format: ZZZ = +00 - 18,Dokumentendatum,,DTM,2379,,303,,CCYYMMDDHHMMZZZ,X, - 19,Währungsangaben,,CUX,,,,,,Muss, - 20,Währungsangaben,,CUX,6347,,2,,Referenzwährung,X, - 21,Währungsangaben,,CUX,6345,,EUR,,Euro,X, - 22,Währungsangaben,,CUX,6343,,4,,Währung der Rechnung,X, - 23,MP-ID Absender,SG1,,,,,,,Muss, - 24,MP-ID Absender,SG1,NAD,,,,,,Muss, - 25,MP-ID Absender,SG1,NAD,3035,,,,"Beteiligter, Qualifier",, - 26,MP-ID Absender,SG1,NAD,3035,,MS,,Dokumenten-/Nachrichtenausstellerbzw. -absender,X, - 27,MP-ID Absender,SG1,NAD,3039,,,,MP-ID,X,[3] Nur MP-ID aus Sparte Strom - 28,MP-ID Absender,SG1,NAD,3055,,9,,GS1,X, - 29,MP-ID Absender,SG1,NAD,3055,,293,,"DE, BDEW(Bundesverband derEnergie- undWasserwirtschaft e.V.)",X, - 30,Ansprechpartner,SG1,CTA,,,,,,Muss, - 31,Ansprechpartner,SG1,CTA,3139,,,,"Funktion des Ansprechpartners,Code",, - 32,Ansprechpartner,SG1,CTA,3139,,IC,,Informationsstelle,X, - 33,Ansprechpartner,SG1,CTA,3412,,,,Abteilung oder Bearbeiter,X, - 34,Kommunikationsverbindung,SG1,COM,,,,,,Muss, - 35,Kommunikationsverbindung,SG1,COM,3148,,,,"Kommunikationsadresse,Identifikation",X, - 36,Kommunikationsverbindung,SG1,COM,3155,,EM,,E-Mail,X [1P0..1], - 37,Kommunikationsverbindung,SG1,COM,3155,,FX,,Telefax,X [1P0..1], - 38,Kommunikationsverbindung,SG1,COM,3155,,TE,,Telefon,X [1P0..1], - 39,Kommunikationsverbindung,SG1,COM,3155,,AJ,,weiteres Telefon,X [1P0..1], - 40,Kommunikationsverbindung,SG1,COM,3155,,AL,,Handy,X [1P0..1], - 41,MP-ID Empfänger,SG1,,,,,,,Muss, - 42,MP-ID Empfänger,SG1,NAD,,,,,,Muss, - 43,MP-ID Empfänger,SG1,NAD,3035,,,,"Beteiligter, Qualifier",, - 44,MP-ID Empfänger,SG1,NAD,3035,,MR,,Nachrichtenempfänger,X, - 45,MP-ID Empfänger,SG1,NAD,3039,,,,MP-ID,X,[3] Nur MP-ID aus Sparte Strom - 46,MP-ID Empfänger,SG1,NAD,3055,,9,,GS1,X, - 47,MP-ID Empfänger,SG1,NAD,3055,,293,,"DE, BDEW(Bundesverband derEnergie- undWasserwirtschaft e.V.)",X, - 48,MP-ID Empfänger,SG1,NAD,3055,,332,,"DE, DVGW Service &Consult GmbH",X, - 49,Dokument-/Nachricht- Einzelheiten,SG2,,,,,,,Muss, - 50,Dokument-/Nachricht- Einzelheiten,SG2,DOC,,,,,,Muss, - 51,Dokument-/Nachricht- Einzelheiten,SG2,DOC,1001,,380,,Handelsrechnung,X, - 52,Dokument-/Nachricht- Einzelheiten,SG2,DOC,1001,,270,,Lieferschein,, - 53,Dokument-/Nachricht- Einzelheiten,SG2,DOC,1001,,Z41,,Lieferschein Grund- /Arbeitspreis,, - 54,Dokument-/Nachricht- Einzelheiten,SG2,DOC,1001,,Z42,,Lieferschein Arbeits- /Leistungspreis,,"[507] Hinweis: Der Code 270 ist nur zu nutzen, wenn ein Lieferschein, der vor dem 1. 4.2021 erstellt wurde, storniert wird." - 55,Dokument-/Nachricht- Einzelheiten,SG2,DOC,1004,,,,Dokumentennummer,X [505],"[505] Hinweis: BGM DE1004 aus der vorher per REMADV abgelehnten INVOIC-Nachricht - [506] Hinweis: BGM DE1004 aus der vorher per IFTSTA abgelehnten MSCONS- Nachricht" - 56,angeforderter Betrag,SG2,MOA,,,,,,Muss, - 57,angeforderter Betrag,SG2,MOA,5025,,9,,Fälliger Betrag (inkl. USt.),X, - 58,angeforderter Betrag,SG2,MOA,5004,,,,Geldbetrag,X [930],[930] Format: max. 2 Nachkommastellen - 59,Begründung der Korrektheit,SG3,,,,,,,Muss, - 60,Begründung der Korrektheit,SG3,AJT,,,,,,Muss, - 61,Begründung der Korrektheit,SG3,AJT,4465,,,,"Anpassungsgrund, Code",X, - 62,Begründung der Korrektheit,SG3,AJT,1082,,Codeliste Strom Nr.S_0108Codeliste Strom Nr.S_0109,,PositionsnummerS_0108S_0109,X [492], - 63,Begründung der Korrektheit,SG3,AJT,1082,,E_0504,,EBD Nr. E_0504,X [492], - 64,Begründung der Korrektheit,SG3,AJT,1082,,E_0265,,EBD Nr. E_0265,X [492], - 65,Begründung der Korrektheit,SG3,AJT,1082,,E_0516,,EBD Nr. E_0516,X [492], - 66,Begründung der Korrektheit,SG3,AJT,1082,,E_0520,,EBD Nr. E_0520,X [492], - 67,Begründung der Korrektheit,SG3,AJT,1082,,E_1008,,EBD Nr. E_1008,X [493],"[492] Wenn MP-ID in NAD+MR (Nachrichtenempfänger) aus Sparte Strom - [493] Wenn MP-ID in NAD+MR (Nachrichtenempfänger) aus Sparte Gas" - 68,Begründung Richtigkeit mit Angabe einer Nachrichtenreferenz,SG3,FTX,,,,,,Muss [4] ⊻ [5] ⊻[20],"[4] wenn SG3 AJT+Z58/Z59/ Z60/Z61/Z62+S_0109 vorhanden - [5] wenn SG3 AJT+A01/A02/ A03/A04/A06/A07/A09/A12/ A15+E_0504 vorhanden - [20] wenn SG3 AJT+A01/ A02/A03/A04/A06/A07/A09/ A15+E_1008 vorhanden" - 69,Begründung Richtigkeit mit Angabe einer Nachrichtenreferenz,SG3,FTX,4451,,ACD,,Begründung,X, - 70,Begründung Richtigkeit mit Angabe einer Nachrichtenreferenz,SG3,FTX,4441,,,,Nachrichtentyp,, - 71,Begründung Richtigkeit mit Angabe einer Nachrichtenreferenz,SG3,FTX,4441,,Z07,,MSCONS,X [1], - 72,Begründung Richtigkeit mit Angabe einer Nachrichtenreferenz,SG3,FTX,4441,,Z08,,UTILMD,X [2], - 73,Begründung Richtigkeit mit Angabe einer Nachrichtenreferenz,SG3,FTX,4441,,Z09,,INVOIC,X [6] ⊻ [13], - 74,Begründung Richtigkeit mit Angabe einer Nachrichtenreferenz,SG3,FTX,4441,,Z10,,ORDERS,X [7] ⊻ [14], - 75,Begründung Richtigkeit mit Angabe einer Nachrichtenreferenz,SG3,FTX,4441,,Z11,,PRICAT,X [8] ⊻ [15], - 76,Begründung Richtigkeit mit Angabe einer Nachrichtenreferenz,SG3,FTX,4441,,Z12,,IFTSTA,X [10] ⊻ [16], - 77,Begründung Richtigkeit mit Angabe einer Nachrichtenreferenz,SG3,FTX,4441,,Z13,,ORDCHG,X [11] ⊻ [17],"[1] wenn SG3 AJT+Z61+S_0109 oder SG3 AJT+Z62+S_0109 vorhanden. - [2] wenn SG3 AJT+Z58+S_0109 oder SG3 AJT+Z59+S_0109 oder SG3 AJT+Z60+S_0109 vorhanden. - [6] wenn SG3 AJT+A07+E_0504 vorhanden - [7] wenn SG3 AJT+A02+E_0504 vorhanden - [8] wenn SG3 AJT+A01/A04/ A06/A09/A12+E_0504 vorhanden - [10] wenn SG3 AJT+A03+E_0504 vorhanden - [11] wenn SG3 AJT+A15+E_0504 vorhanden - [13] wenn SG3 AJT+A07+E_1008 vorhanden - [14] wenn SG3 AJT+A02+E_1008 vorhanden - [15] wenn SG3 AJT+A01/" - 78,Begründung Richtigkeit mit Angabe einer Nachrichtenreferenz,SG3,FTX,4440,,,,Datenaustauschreferenz derreferenzierten Datei,X, - 79,Begründung Richtigkeit mit Angabe einer Nachrichtenreferenz,SG3,FTX,4440,,,,Nachrichten-/Vorgangsnummer,X, - 80,Begründung Richtigkeit mit Angabe einer Nachrichtenreferenz,SG3,FTX,4440,,,,Datenaustauschreferenz derEmpfangsbestätigung,X, - 81,Begründung Richtigkeit mit Angabe von Freitext,SG3,FTX,,,,,,Muss [9] ⊻ [12] ⊻[18] ⊻ [19],"[9] wenn SG3 AJT+A05/A10/ A11/A14+E_0504 vorhanden - [12] wenn SG3 AJT+A99+S_0109 vorhanden - [18] wenn SG3 AJT+A05/ A10/A11+E_1008 vorhanden - [19] wenn SG3 AJT+A99+E_0265/E_0516/ E_0520 vorhanden" - 82,Begründung Richtigkeit mit Angabe von Freitext,SG3,FTX,4451,,ACB,,ZusätzlicheInformationen (fürallgemeine Hinweise),X, - 83,Begründung Richtigkeit mit Angabe von Freitext,SG3,FTX,4440,,,,Freier Text,X, - 84,Nachrichten-Endesegment,,UNT,,,,,,Muss, - 85,Nachrichten-Endesegment,,UNT,0074,,,,Anzahl der Segmente in einerNachricht,X, - 86,Nachrichten-Endesegment,,UNT,0062,,,,Nachrichten-Referenznummer,X, - - ''', - '29002.csv': ''' - ,Segmentname,Segmentgruppe,Segment,Datenelement,Segment ID,Code,Qualifier,Beschreibung,Bedingungsausdruck,Bedingung - 0,Nachrichten-Kopfsegment,,UNH,,,,,,Muss, - 1,Nachrichten-Kopfsegment,,UNH,0062,,,,Nachrichten-Referenznummer,X, - 2,Nachrichten-Kopfsegment,,UNH,0065,,COMDIS,,Handelsunstimmigkeit,X, - 3,Nachrichten-Kopfsegment,,UNH,0052,,D,,Entwurfs-Version,X, - 4,Nachrichten-Kopfsegment,,UNH,0054,,17A,,Ausgabe 2017 - A,X, - 5,Nachrichten-Kopfsegment,,UNH,0051,,UN,,UN/CEFACT,X, - 6,Nachrichten-Kopfsegment,,UNH,0057,,1.0c,,Versionsnummer derzugrundeliegendenBDEW-Nachrichtenbeschreibung,X, - 7,Beginn der Nachricht,,BGM,,,,,,Muss, - 8,Beginn der Nachricht,,BGM,1001,,456,,Belastungsanzeige,, - 9,Beginn der Nachricht,,BGM,1001,,739,,"MSCONS, die eineINVOIC unterstützt",X, - 10,Beginn der Nachricht,,BGM,1004,,,,Dokumentennummer,X, - 11,Prüfidentifikator,,RFF,,,,,,Muss, - 12,Prüfidentifikator,,RFF,1153,,Z13,,Prüfidentifikator,X, - 13,Prüfidentifikator,,RFF,1154,,29001,,Ablehnung REMADV,, - 14,Prüfidentifikator,,RFF,1154,,29002,,Ablehnung IFTSTA,X, - 15,Dokumentendatum,,DTM,,,,,,Muss, - 16,Dokumentendatum,,DTM,2005,,137,,Dokumenten-/Nachrichtendatum/-zeit,X, - 17,Dokumentendatum,,DTM,2380,,,,"Datum oder Uhrzeit oderZeitspanne, Wert",X [931],[931] Format: ZZZ = +00 - 18,Dokumentendatum,,DTM,2379,,303,,CCYYMMDDHHMMZZZ,X, - 19,Währungsangaben,,CUX,,,,,,, - 20,Währungsangaben,,CUX,6347,,2,,Referenzwährung,, - 21,Währungsangaben,,CUX,6345,,EUR,,Euro,, - 22,Währungsangaben,,CUX,6343,,4,,Währung der Rechnung,, - 23,MP-ID Absender,SG1,,,,,,,Muss, - 24,MP-ID Absender,SG1,NAD,,,,,,Muss, - 25,MP-ID Absender,SG1,NAD,3035,,,,"Beteiligter, Qualifier",, - 26,MP-ID Absender,SG1,NAD,3035,,MS,,Dokumenten-/Nachrichtenausstellerbzw. -absender,X, - 27,MP-ID Absender,SG1,NAD,3039,,,,MP-ID,X [3],[3] Nur MP-ID aus Sparte Strom - 28,MP-ID Absender,SG1,NAD,3055,,9,,GS1,X, - 29,MP-ID Absender,SG1,NAD,3055,,293,,"DE, BDEW(Bundesverband derEnergie- undWasserwirtschaft e.V.)",X, - 30,Ansprechpartner,SG1,CTA,,,,,,Muss, - 31,Ansprechpartner,SG1,CTA,3139,,,,"Funktion des Ansprechpartners,Code",, - 32,Ansprechpartner,SG1,CTA,3139,,IC,,Informationsstelle,X, - 33,Ansprechpartner,SG1,CTA,3412,,,,Abteilung oder Bearbeiter,X, - 34,Kommunikationsverbindung,SG1,COM,,,,,,Muss, - 35,Kommunikationsverbindung,SG1,COM,3148,,,,"Kommunikationsadresse,Identifikation",X, - 36,Kommunikationsverbindung,SG1,COM,3155,,EM,,E-Mail,X [1P0..1], - 37,Kommunikationsverbindung,SG1,COM,3155,,FX,,Telefax,X [1P0..1], - 38,Kommunikationsverbindung,SG1,COM,3155,,TE,,Telefon,X [1P0..1], - 39,Kommunikationsverbindung,SG1,COM,3155,,AJ,,weiteres Telefon,X [1P0..1], - 40,Kommunikationsverbindung,SG1,COM,3155,,AL,,Handy,X [1P0..1], - 41,MP-ID Empfänger,SG1,,,,,,,Muss, - 42,MP-ID Empfänger,SG1,NAD,,,,,,Muss, - 43,MP-ID Empfänger,SG1,NAD,3035,,,,"Beteiligter, Qualifier",, - 44,MP-ID Empfänger,SG1,NAD,3035,,MR,,Nachrichtenempfänger,X, - 45,MP-ID Empfänger,SG1,NAD,3039,,,,MP-ID,X [3],[3] Nur MP-ID aus Sparte Strom - 46,MP-ID Empfänger,SG1,NAD,3055,,9,,GS1,X, - 47,MP-ID Empfänger,SG1,NAD,3055,,293,,"DE, BDEW(Bundesverband derEnergie- undWasserwirtschaft e.V.)",X, - 48,MP-ID Empfänger,SG1,NAD,3055,,332,,"DE, DVGW Service &Consult GmbH",, - 49,Dokument-/Nachricht- Einzelheiten,SG2,,,,,,,Muss, - 50,Dokument-/Nachricht- Einzelheiten,SG2,DOC,,,,,,Muss, - 51,Dokument-/Nachricht- Einzelheiten,SG2,DOC,1001,,380,,Handelsrechnung,, - 52,Dokument-/Nachricht- Einzelheiten,SG2,DOC,1001,,270,,Lieferschein,X [507], - 53,Dokument-/Nachricht- Einzelheiten,SG2,DOC,1001,,Z41,,Lieferschein Grund- /Arbeitspreis,X, - 54,Dokument-/Nachricht- Einzelheiten,SG2,DOC,1001,,Z42,,Lieferschein Arbeits- /Leistungspreis,X,"[507] Hinweis: Der Code 270 ist nur zu nutzen, wenn ein Lieferschein, der vor dem 1. 4.2021 erstellt wurde, storniert wird." - 55,Dokument-/Nachricht- Einzelheiten,SG2,DOC,1004,,,,Dokumentennummer,X [506],"[505] Hinweis: BGM DE1004 aus der vorher per REMADV abgelehnten INVOIC-Nachricht - [506] Hinweis: BGM DE1004 aus der vorher per IFTSTA abgelehnten MSCONS- Nachricht" - 56,angeforderter Betrag,SG2,MOA,,,,,,, - 57,angeforderter Betrag,SG2,MOA,5025,,9,,Fälliger Betrag (inkl. USt.),, - 58,angeforderter Betrag,SG2,MOA,5004,,,,Geldbetrag,,[930] Format: max. 2 Nachkommastellen - 59,Begründung der Korrektheit,SG3,,,,,,,Muss, - 60,Begründung der Korrektheit,SG3,AJT,,,,,,Muss, - 61,Begründung der Korrektheit,SG3,AJT,4465,,,,"Anpassungsgrund, Code",X, - 62,Begründung der Korrektheit,SG3,AJT,1082,,Codeliste Strom Nr.S_0108Codeliste Strom Nr.S_0109,,PositionsnummerS_0108S_0109,X [492], - 63,Begründung der Korrektheit,SG3,AJT,1082,,E_0504,,EBD Nr. E_0504,, - 64,Begründung der Korrektheit,SG3,AJT,1082,,E_0265,,EBD Nr. E_0265,, - 65,Begründung der Korrektheit,SG3,AJT,1082,,E_0516,,EBD Nr. E_0516,, - 66,Begründung der Korrektheit,SG3,AJT,1082,,E_0520,,EBD Nr. E_0520,, - 67,Begründung der Korrektheit,SG3,AJT,1082,,E_1008,,EBD Nr. E_1008,,"[492] Wenn MP-ID in NAD+MR (Nachrichtenempfänger) aus Sparte Strom - [493] Wenn MP-ID in NAD+MR (Nachrichtenempfänger) aus Sparte Gas" - 68,Begründung Richtigkeit mit Angabe einer Nachrichtenreferenz,SG3,FTX,,,,,,,"[4] wenn SG3 AJT+Z58/Z59/ Z60/Z61/Z62+S_0109 vorhanden - [5] wenn SG3 AJT+A01/A02/ A03/A04/A06/A07/A09/A12/ A15+E_0504 vorhanden - [20] wenn SG3 AJT+A01/ A02/A03/A04/A06/A07/A09/ A15+E_1008 vorhanden" - 69,Begründung Richtigkeit mit Angabe einer Nachrichtenreferenz,SG3,FTX,4451,,ACD,,Begründung,, - 70,Begründung Richtigkeit mit Angabe einer Nachrichtenreferenz,SG3,FTX,4441,,,,Nachrichtentyp,, - 71,Begründung Richtigkeit mit Angabe einer Nachrichtenreferenz,SG3,FTX,4441,,Z07,,MSCONS,, - 72,Begründung Richtigkeit mit Angabe einer Nachrichtenreferenz,SG3,FTX,4441,,Z08,,UTILMD,, - 73,Begründung Richtigkeit mit Angabe einer Nachrichtenreferenz,SG3,FTX,4441,,Z09,,INVOIC,, - 74,Begründung Richtigkeit mit Angabe einer Nachrichtenreferenz,SG3,FTX,4441,,Z10,,ORDERS,, - 75,Begründung Richtigkeit mit Angabe einer Nachrichtenreferenz,SG3,FTX,4441,,Z11,,PRICAT,, - 76,Begründung Richtigkeit mit Angabe einer Nachrichtenreferenz,SG3,FTX,4441,,Z12,,IFTSTA,, - 77,Begründung Richtigkeit mit Angabe einer Nachrichtenreferenz,SG3,FTX,4441,,Z13,,ORDCHG,,"[1] wenn SG3 AJT+Z61+S_0109 oder SG3 AJT+Z62+S_0109 vorhanden. - [2] wenn SG3 AJT+Z58+S_0109 oder SG3 AJT+Z59+S_0109 oder SG3 AJT+Z60+S_0109 vorhanden. - [6] wenn SG3 AJT+A07+E_0504 vorhanden - [7] wenn SG3 AJT+A02+E_0504 vorhanden - [8] wenn SG3 AJT+A01/A04/ A06/A09/A12+E_0504 vorhanden - [10] wenn SG3 AJT+A03+E_0504 vorhanden - [11] wenn SG3 AJT+A15+E_0504 vorhanden - [13] wenn SG3 AJT+A07+E_1008 vorhanden - [14] wenn SG3 AJT+A02+E_1008 vorhanden - [15] wenn SG3 AJT+A01/" - 78,Begründung Richtigkeit mit Angabe einer Nachrichtenreferenz,SG3,FTX,4440,,,,Datenaustauschreferenz derreferenzierten Datei,, - 79,Begründung Richtigkeit mit Angabe einer Nachrichtenreferenz,SG3,FTX,4440,,,,Nachrichten-/Vorgangsnummer,, - 80,Begründung Richtigkeit mit Angabe einer Nachrichtenreferenz,SG3,FTX,4440,,,,Datenaustauschreferenz derEmpfangsbestätigung,, - 81,Begründung Richtigkeit mit Angabe von Freitext,SG3,FTX,,,,,,Muss,"[9] wenn SG3 AJT+A05/A10/ A11/A14+E_0504 vorhanden - [12] wenn SG3 AJT+A99+S_0109 vorhanden - [18] wenn SG3 AJT+A05/ A10/A11+E_1008 vorhanden - [19] wenn SG3 AJT+A99+E_0265/E_0516/ E_0520 vorhanden" - 82,Begründung Richtigkeit mit Angabe von Freitext,SG3,FTX,4451,,ACB,,ZusätzlicheInformationen (fürallgemeine Hinweise),X, - 83,Begründung Richtigkeit mit Angabe von Freitext,SG3,FTX,4440,,,,Freier Text,X, - 84,Nachrichten-Endesegment,,UNT,,,,,,Muss, - 85,Nachrichten-Endesegment,,UNT,0074,,,,Anzahl der Segmente in einerNachricht,X, - 86,Nachrichten-Endesegment,,UNT,0062,,,,Nachrichten-Referenznummer,X, - - ''', - '37000.csv': ''' - ,Segmentname,Segmentgruppe,Segment,Datenelement,Segment ID,Code,Qualifier,Beschreibung,Bedingungsausdruck,Bedingung - 0,Nachrichten-Kopfsegment,,UNH,,,,,,Muss, - 1,Nachrichten-Kopfsegment,,UNH,0062,,,,Nachrichten-Referenznummer,X, - 2,Nachrichten-Kopfsegment,,UNH,0065,,PARTIN,,Partnerstammdaten,X, - 3,Nachrichten-Kopfsegment,,UNH,0052,,D,,Entwurfs-Version,X, - 4,Nachrichten-Kopfsegment,,UNH,0054,,20B,,Ausgabe 2020 - B,X, - 5,Nachrichten-Kopfsegment,,UNH,0051,,UN,,UN/CEFACT,X, - 6,Nachrichten-Kopfsegment,,UNH,0057,,1.0c,,Versionsnummer derzugrundeliegendenBDEW-Nachrichtenbeschreibung,X, - 7,Beginn der Nachricht,,BGM,,,,,,Muss, - 8,Beginn der Nachricht,,BGM,1001,,10,,Partnerstammdaten,X, - 9,Beginn der Nachricht,,BGM,1004,,,,Dokumentennummer,X, - 10,Beginn der Nachricht,,BGM,1373,,11,,Dokument nichtverfügbar,S [9],[9] Wenn die Kommunikationsdaten vom Absender nicht mehr aktiv sind. - 11,Nachrichtendatum,,DTM,,,,,,Muss, - 12,Nachrichtendatum,,DTM,2005,,137,,Dokumenten-/Nachrichtendatum/-zeit,X, - 13,Nachrichtendatum,,DTM,2380,,,,"Datum oder Uhrzeit oderZeitspanne, Wert",X [931][494],"[494] Das hier genannte Datum muss der Zeitpunkt sein, zu dem das Dokument erstellt wurde, oder ein Zeitpunkt, der davor liegt. - [931] Format: ZZZ = +00" - 14,Nachrichtendatum,,DTM,2379,,303,,CCYYMMDDHHMMZZZ,X, - 15,Prüfidentifikator,SG1,,,,,,,Muss, - 16,Prüfidentifikator,SG1,RFF,,,,,,Muss, - 17,Prüfidentifikator,SG1,RFF,1153,,Z13,,Prüfidentifikator,X, - 18,Prüfidentifikator,SG1,RFF,1154,,37000,,ÜbermittlungKommunikationsdatendes LF,X, - 19,Prüfidentifikator,SG1,RFF,1154,,37001,,ÜbermittlungKommunikationsdatendes NB,, - 20,Prüfidentifikator,SG1,RFF,1154,,37002,,ÜbermittlungKommunikationsdatendes MSB,, - 21,Versionsnummer,SG1,,,,,,,Muss, - 22,Versionsnummer,SG1,RFF,,,,,,Muss, - 23,Versionsnummer,SG1,RFF,1153,,AGK,,Anwendungsreferenznummer,X, - 24,Versionsnummer,SG1,RFF,1056,,,,Versionsnummer,X [908][505],"[505] Wenn eine Vorgängerversion (RFF+ACW) angegeben ist, so muss der Wert in diesem DE1056 mindestens um 1 höher sein, als der Wert aus DE1056 der Vorgängerversion (RFF+ACW). - [908] Format: Mögliche Werte: 1 bis n" - 25,Gültig Ab,SG1,DTM,,,,,,Soll [4],[4] Wenn Vorgängerversion vorhanden - 26,Gültig Ab,SG1,DTM,2005,,157,,"Gültigkeit, Beginndatum",X, - 27,Gültig Ab,SG1,DTM,2380,,,,"Datum oder Uhrzeit oderZeitspanne, Wert",X [UB1], - 28,Gültig Ab,SG1,DTM,2379,,303,,CCYYMMDDHHMMZZZ,X, - 29,Vorgängerversion,SG1,,,,,,,Soll [4],[4] Wenn Vorgängerversion vorhanden - 30,Vorgängerversion,SG1,RFF,,,,,,Muss, - 31,Vorgängerversion,SG1,RFF,1153,,ACW,,Referenznummer einervorangegangenenNachricht,X, - 32,Vorgängerversion,SG1,RFF,1056,,,,Versionsnummer,X [908],[908] Format: Mögliche Werte: 1 bis n - 33,MP-ID Absender,SG2,,,,,,,Muss, - 34,MP-ID Absender,SG2,NAD,,,,,,Muss, - 35,MP-ID Absender,SG2,NAD,3035,,MS,,Dokumenten-/Nachrichtenausstellerbzw. -absender,X, - 36,MP-ID Absender,SG2,NAD,3039,,,,MP-ID,X [1],[1] Nur MP-ID aus Sparte Strom - 37,MP-ID Absender,SG2,NAD,3055,,9,,GS1,X, - 38,MP-ID Absender,SG2,NAD,3055,,293,,"DE, BDEW",X, - 39,Ansprechpartner,SG3,,,,,,,Kann, - 40,Ansprechpartner,SG3,CTA,,,,,,Muss, - 41,Ansprechpartner,SG3,CTA,3139,,IC,,Informationskontakt,X, - 42,Ansprechpartner,SG3,CTA,3412,,,,Name vom Ansprechpartner,X, - 43,Kommunikationsverbindung,SG3,COM,,,,,,Muss, - 44,Kommunikationsverbindung,SG3,COM,3148,,,,Nummer / Adresse,X (([939][6])∨ ([940][7]))∧ [502],"[6] wenn im DE3155 im demselben COM der Code EM vorhanden ist - [7] wenn im DE3155 im demselben COM der Code TE / FX / AJ / AL vorhanden ist - [502] Hinweis: Es darf nur eine Information im DE3148 übermittelt werden - [939] Format: Die Zeichenkette muss die Zeichen @ und . enthalten - [940] Format: Die Zeichenkette muss mit dem Zeichen + beginnen und danach dürfen nur noch Ziffern folgen" - 45,Kommunikationsverbindung,SG3,COM,3155,,EM,,Elektronische Post,X [1P0..1], - 46,Kommunikationsverbindung,SG3,COM,3155,,FX,,Telefax,X [1P0..1], - 47,Kommunikationsverbindung,SG3,COM,3155,,TE,,Telefon,X [1P0..1], - 48,Kommunikationsverbindung,SG3,COM,3155,,AJ,,weiteres Telefon,X [1P0..1], - 49,Kommunikationsverbindung,SG3,COM,3155,,AL,,Handy,X [1P0..1], - 50,MP-ID Empfänger,SG2,,,,,,,Muss, - 51,MP-ID Empfänger,SG2,NAD,,,,,,Muss, - 52,MP-ID Empfänger,SG2,NAD,3035,,MR,,Nachrichtenempfänger,X, - 53,MP-ID Empfänger,SG2,NAD,3039,,,,MP-ID,X [1],[1] Nur MP-ID aus Sparte Strom - 54,MP-ID Empfänger,SG2,NAD,3055,,9,,GS1,X, - 55,MP-ID Empfänger,SG2,NAD,3055,,293,,"DE, BDEW",X, - 56,Abschnitts-Kontrollsegment,,UNS,,,,,,Muss, - 57,Abschnitts-Kontrollsegment,,UNS,0081,,D,,Trennung von Kopf- undPositionsteil,X, - 58,Name und Adresse des Unternehmens,SG4,,,,,,,Muss [10],[10] Wenn BGM DE1373 = 11 (Dokument nicht verfügbar) nicht vorhanden - 59,Name und Adresse des Unternehmens,SG4,NAD,,,,,,Muss, - 60,Name und Adresse des Unternehmens,SG4,NAD,3035,,SU,,Lieferant,X, - 61,Name und Adresse des Unternehmens,SG4,NAD,3035,,DDM,,Netzbetreiber,, - 62,Name und Adresse des Unternehmens,SG4,NAD,3035,,DEB,,Messstellenbetreiber,, - 63,Name und Adresse des Unternehmens,SG4,NAD,3036,,,,Name,X [506],"[506] Hinweis: Das Datenelement ist so zu füllen, dass sein Inhalt den Vorgaben des USt.- Gesetzes genügt, so dass der Empfänger diese Daten in einer INVOIC nutzen kann." - 64,Name und Adresse des Unternehmens,SG4,NAD,3045,,Z02,,Struktur derFirmenbezeichnung,X, - 65,Name und Adresse des Unternehmens,SG4,NAD,3042,,,,Straße und Hausnummer oderPostfach,X [506],"[506] Hinweis: Das Datenelement ist so zu füllen, dass sein Inhalt den Vorgaben des USt.- Gesetzes genügt, so dass der Empfänger diese Daten in einer INVOIC nutzen kann." - 66,Name und Adresse des Unternehmens,SG4,NAD,3164,,,,Ort,X [506],"[506] Hinweis: Das Datenelement ist so zu füllen, dass sein Inhalt den Vorgaben des USt.- Gesetzes genügt, so dass der Empfänger diese Daten in einer INVOIC nutzen kann." - 67,Name und Adresse des Unternehmens,SG4,NAD,3251,,,,Postleitzahl,M [2] ∧[506]S [3] ∧ [506],"[2] Wenn der Code im DE3207 in der ""EDI@Energy Codeliste der europäischen Ländercodes"" in der Spalte ""PLZ vorhanden""" - 68,Name und Adresse des Unternehmens,SG4,NAD,3207,,,,"Ländername, Code",X [506],"[506] Hinweis: Das Datenelement ist so zu füllen, dass sein Inhalt den Vorgaben des USt.- Gesetzes genügt, so dass der Empfänger diese Daten in einer INVOIC nutzen kann." - 69,Bankverbindung,SG4,FII,,,,,,Muss, - 70,Bankverbindung,SG4,FII,3035,,BK,,Kreditinstitut,X, - 71,Bankverbindung,SG4,FII,3194,,IBAN,,,X, - 72,Bankverbindung,SG4,FII,3192,,,,Name des Kontoinhabers,X, - 73,Bankverbindung,SG4,FII,3192,,,,Name des Kontoinhabers,K, - 74,Bankverbindung,SG4,FII,3433,,BIC,,,X, - 75,Bankverbindung,SG4,FII,3432,,,,Name des Kredinstituts,X, - 76,Internetseite (URL),SG4,FTX,,,,,,Muss, - 77,Internetseite (URL),SG4,FTX,4451,,Z13,,Internetseite,X, - 78,Internetseite (URL),SG4,FTX,4440,,,,Internetseite,X, - 79,Gericht und Handelsregister-Nummer,SG4,FTX,,,,,,Soll [3],[3] wenn vorhanden - 80,Gericht und Handelsregister-Nummer,SG4,FTX,4451,,Z15,,Gericht undHandelsregister-Nummer,X, - 81,Gericht und Handelsregister-Nummer,SG4,FTX,4440,,,,Gericht,X, - 82,Gericht und Handelsregister-Nummer,SG4,FTX,4440,,,,Handelsregister-Nummer,X, - 83,"Steuernummer, Umsatzsteuernummer",SG6,,,,,,,Muss [504],[504] Hinweis: Es ist mindestens die - 84,"Steuernummer, Umsatzsteuernummer",SG6,RFF,,,,,,Muss, - 85,"Steuernummer, Umsatzsteuernummer",SG6,RFF,1153,,VA,,Umsatzsteuernummer,X [2P0..1] ⊻[3P1..1], - 86,"Steuernummer, Umsatzsteuernummer",SG6,RFF,1153,,FC,,Steuernummer,X [2P0..1], - 87,"Steuernummer, Umsatzsteuernummer",SG6,RFF,1154,,,,"Referenz, Identifikation",X, - 88,Faxnummer,SG6,RFF,,,,,,Kann, - 89,Faxnummer,SG6,RFF,1153,,Z25,,Faxnummer,X, - 90,Faxnummer,SG6,RFF,1154,,,,Faxnummer,X [940],[940] Format: Die Zeichenkette muss mit dem Zeichen + beginnen und danach dürfen nur noch Ziffern folgen - 91,Erreichbarkeit an Werktagen,SG12,,,,,,,Muss, - 92,Erreichbarkeit an Werktagen,SG12,CCI,,,,,,Muss, - 93,Erreichbarkeit an Werktagen,SG12,CCI,7059,,Z40,,Erreichbarkeit desUnternehmens,X, - 94,Erreichbarkeit,SG12,DTM,,,,,,Muss, - 95,Erreichbarkeit,SG12,DTM,2005,,Z36,,Verfügbarkeit Montag,X [1P1..1], - 96,Erreichbarkeit,SG12,DTM,2005,,Z37,,Verfügbarkeit Dienstag,X [1P1..1], - 97,Erreichbarkeit,SG12,DTM,2005,,Z38,,Verfügbarkeit Mittwoch,X [1P1..1], - 98,Erreichbarkeit,SG12,DTM,2005,,Z39,,VerfügbarkeitDonnerstag,X [1P1..1], - 99,Erreichbarkeit,SG12,DTM,2005,,Z40,,Verfügbarkeit Freitag,X [1P1..1], - 100,Erreichbarkeit,SG12,DTM,2005,,Z41,,Mittagspause (=Ausschluss derVerfügbarkeit),X [1P0..1], - 101,Erreichbarkeit,SG12,DTM,2380,,,,"Datum oder Uhrzeit oderZeitspanne, Wert",X [503],[503] Hinweis: Angabe erfolgt in gesetzlicher deutscher Zeit - 102,Erreichbarkeit,SG12,DTM,2379,,501,,HHMMHHMM,X, - 103,Name und Anschrift Ansprechpartner Übertragungsweg / Datenaustausch,SG4,,,,,,,Muss [10],[10] Wenn BGM DE1373 = 11 (Dokument nicht verfügbar) nicht - 104,Name und Anschrift Ansprechpartner Übertragungsweg / Datenaustausch,SG4,NAD,,,,,,Muss, - 105,Name und Anschrift Ansprechpartner Übertragungsweg / Datenaustausch,SG4,NAD,3035,,Z10,,AnsprechpartnerÜbertragungsweg /Datenaustausch,X, - 106,Name und Anschrift Ansprechpartner Übertragungsweg / Datenaustausch,SG4,NAD,3036,,,,Name,X [500],[500] Hinweis: Es kann der Firmenname eines Dienstleisters oder die identische Firmenbezeichnung aus SG4 NAD+SU / DDM / DEB / Z31 / Z34 / Z35 / Z36 eingetragen werden. - 107,Name und Anschrift Ansprechpartner Übertragungsweg / Datenaustausch,SG4,NAD,3045,,Z02,,Struktur derFirmenbezeichnung,X, - 108,Name und Anschrift Ansprechpartner Übertragungsweg / Datenaustausch,SG4,NAD,3042,,,,Straße und Hausnummer oderPostfach,X, - 109,Name und Anschrift Ansprechpartner Übertragungsweg / Datenaustausch,SG4,NAD,3164,,,,Ort,X, - 110,Name und Anschrift Ansprechpartner Übertragungsweg / Datenaustausch,SG4,NAD,3251,,,,Postleitzahl,M [2]S [3],"[2] Wenn der Code im DE3207 in der ""EDI@Energy Codeliste der europäischen Ländercodes"" in der Spalte ""PLZ vorhanden"" ein ""X"" enthält - [3] wenn vorhanden" - 111,Name und Anschrift Ansprechpartner Übertragungsweg / Datenaustausch,SG4,NAD,3207,,,,"Ländername, Code",X, - 112,Ansprechpartner,SG7,,,,,,,Muss, - 113,Ansprechpartner,SG7,CTA,,,,,,Muss, - 114,Ansprechpartner,SG7,CTA,3139,,IC,,Informationskontakt,X, - 115,Ansprechpartner,SG7,CTA,3412,,,,Name der organisatorischenEinheit,X [501],"[501] Hinweis: Es darf kein Name einer natürlichen Person übermittelt werden, stattdessen ist die organisatorische Einheit im Unternehmen zu nennen." - 116,Kommunikationsverbindung,SG7,COM,,,,,,Muss, - 117,Kommunikationsverbindung,SG7,COM,3148,,,,Nummer / Adresse,X (([939][6])∨ ([940][8]))∧ [502],"[6] wenn im DE3155 im demselben COM der Code EM vorhanden ist - [8] wenn im DE3155 im" - 118,Kommunikationsverbindung,SG7,COM,3155,,EM,,Elektronische Post,X [1P1..1], - 119,Kommunikationsverbindung,SG7,COM,3155,,TE,,Telefon,X [1P1..1], - 120,Kommunikationsverbindung,SG7,COM,3155,,FX,,Telefax,X [1P0..1], - 121,Name und Anschrift Ansprechpartner Rahmenverträge,SG4,,,,,,,Muss [10] ∧[17],"[10] Wenn BGM DE1373 = 11 (Dokument nicht verfügbar) nicht vorhanden - [17] Wenn MP-ID in SG2 NAD+MR (Nachrichtenempfänger) in der Rolle LF/NB/MSB - [18] Wenn MP-ID in SG2 NAD+MR (Nachrichtenempfänger) in der Rolle LF/MSB - [21] Wenn MP-ID in SG2 NAD+MR (Nachrichtenempfänger) in der Rolle LF/NB/ESA" - 122,Name und Anschrift Ansprechpartner Rahmenverträge,SG4,NAD,,,,,,Muss, - 123,Name und Anschrift Ansprechpartner Rahmenverträge,SG4,NAD,3035,,Z11,,AnsprechpartnerRahmenverträge,X, - 124,Name und Anschrift Ansprechpartner Rahmenverträge,SG4,NAD,3036,,,,Name,X [500],[500] Hinweis: Es kann der Firmenname eines Dienstleisters oder die - 125,Name und Anschrift Ansprechpartner Rahmenverträge,SG4,NAD,3045,,Z02,,Struktur derFirmenbezeichnung,X, - 126,Name und Anschrift Ansprechpartner Rahmenverträge,SG4,NAD,3042,,,,Straße und Hausnummer oderPostfach,X, - 127,Name und Anschrift Ansprechpartner Rahmenverträge,SG4,NAD,3164,,,,Ort,X, - 128,Name und Anschrift Ansprechpartner Rahmenverträge,SG4,NAD,3251,,,,Postleitzahl,M [2]S [3],"[2] Wenn der Code im DE3207 in der ""EDI@Energy Codeliste der europäischen Ländercodes"" in der Spalte ""PLZ vorhanden"" ein ""X"" enthält - [3] wenn vorhanden" - 129,Name und Anschrift Ansprechpartner Rahmenverträge,SG4,NAD,3207,,,,"Ländername, Code",X, - 130,Ansprechpartner,SG7,,,,,,,Muss, - 131,Ansprechpartner,SG7,CTA,,,,,,Muss, - 132,Ansprechpartner,SG7,CTA,3139,,IC,,Informationskontakt,X, - 133,Ansprechpartner,SG7,CTA,3412,,,,Name der organisatorischenEinheit,X [501],"[501] Hinweis: Es darf kein Name einer natürlichen Person übermittelt werden, stattdessen ist die organisatorische Einheit im Unternehmen zu nennen." - 134,Kommunikationsverbindung,SG7,COM,,,,,,Muss, - 135,Kommunikationsverbindung,SG7,COM,3148,,,,Nummer / Adresse,X (([939][6])∨ ([940][8]))∧ [502],"[6] wenn im DE3155 im demselben COM der Code EM vorhanden ist - [8] wenn im DE3155 im demselben COM der Code TE / FX vorhanden ist - [502] Hinweis: Es darf nur eine Information im DE3148 übermittelt werden" - 136,Kommunikationsverbindung,SG7,COM,3155,,EM,,Elektronische Post,X [1P1..1], - 137,Kommunikationsverbindung,SG7,COM,3155,,TE,,Telefon,X [1P1..1], - 138,Kommunikationsverbindung,SG7,COM,3155,,FX,,Telefax,X [1P0..1], - 139,Name und Anschrift Ansprechpartner Kündigungsprozess,SG4,,,,,,,Muss [5] ∧[10],"[5] Wenn MP-ID in SG2 NAD+MR (Nachrichtenempfänger) in der Rolle LF - [10] Wenn BGM DE1373 = 11 (Dokument nicht verfügbar) nicht vorhanden - [22] Wenn MP-ID in SG2 NAD+MR (Nachrichtenempfänger) in der Rolle MSB" - 140,Name und Anschrift Ansprechpartner Kündigungsprozess,SG4,NAD,,,,,,Muss, - 141,Name und Anschrift Ansprechpartner Kündigungsprozess,SG4,NAD,3035,,Z12,,AnsprechpartnerKündigungsprozesse,X, - 142,Name und Anschrift Ansprechpartner Kündigungsprozess,SG4,NAD,3036,,,,Name,X [500],[500] Hinweis: Es kann der Firmenname eines Dienstleisters oder die identische Firmenbezeichnung aus SG4 NAD+SU / DDM / DEB / Z31 / Z34 / Z35 / Z36 eingetragen werden. - 143,Name und Anschrift Ansprechpartner Kündigungsprozess,SG4,NAD,3045,,Z02,,Struktur derFirmenbezeichnung,X, - 144,Name und Anschrift Ansprechpartner Kündigungsprozess,SG4,NAD,3042,,,,Straße und Hausnummer oderPostfach,X, - 145,Name und Anschrift Ansprechpartner Kündigungsprozess,SG4,NAD,3164,,,,Ort,X, - 146,Name und Anschrift Ansprechpartner Kündigungsprozess,SG4,NAD,3251,,,,Postleitzahl,M [2]S [3],[2] Wenn der Code im DE3207 in der - 147,Name und Anschrift Ansprechpartner Kündigungsprozess,SG4,NAD,3207,,,,"Ländername, Code",X, - 148,Ansprechpartner,SG7,,,,,,,Muss, - 149,Ansprechpartner,SG7,CTA,,,,,,Muss, - 150,Ansprechpartner,SG7,CTA,3139,,IC,,Informationskontakt,X, - 151,Ansprechpartner,SG7,CTA,3412,,,,Name der organisatorischenEinheit,X [501],"[501] Hinweis: Es darf kein Name einer natürlichen Person übermittelt werden, stattdessen ist die organisatorische Einheit im Unternehmen zu nennen." - 152,Kommunikationsverbindung,SG7,COM,,,,,,Muss, - 153,Kommunikationsverbindung,SG7,COM,3148,,,,Nummer / Adresse,X (([939][6])∨ ([940][8]))∧ [502],"[6] wenn im DE3155 im demselben COM der Code EM vorhanden ist - [8] wenn im DE3155 im demselben COM der Code TE / FX vorhanden ist - [502] Hinweis: Es darf nur eine Information im DE3148 übermittelt werden - [939] Format: Die Zeichenkette muss die Zeichen @ und . enthalten - [940] Format: Die Zeichenkette muss mit dem Zeichen + beginnen und danach dürfen nur noch Ziffern folgen" - 154,Kommunikationsverbindung,SG7,COM,3155,,EM,,Elektronische Post,X [1P1..1], - 155,Kommunikationsverbindung,SG7,COM,3155,,TE,,Telefon,X [1P1..1], - 156,Name und Anschrift Ansprechpartner Wechselprozesse,SG4,,,,,,,Muss [10] ∧[17],"[10] Wenn BGM DE1373 = 11 (Dokument nicht verfügbar) nicht vorhanden - [17] Wenn MP-ID in SG2 NAD+MR (Nachrichtenempfänger) in der Rolle LF/NB/MSB" - 157,Name und Anschrift Ansprechpartner Wechselprozesse,SG4,NAD,,,,,,Muss, - 158,Name und Anschrift Ansprechpartner Wechselprozesse,SG4,NAD,3035,,Z13,,AnsprechpartnerWechselprozesse,X, - 159,Name und Anschrift Ansprechpartner Wechselprozesse,SG4,NAD,3036,,,,Name,X [500],[500] Hinweis: Es kann der Firmenname eines Dienstleisters oder die identische Firmenbezeichnung aus SG4 NAD+SU / DDM / DEB / Z31 / Z34 / Z35 / Z36 eingetragen werden. - 160,Name und Anschrift Ansprechpartner Wechselprozesse,SG4,NAD,3045,,Z02,,Struktur derFirmenbezeichnung,X, - 161,Name und Anschrift Ansprechpartner Wechselprozesse,SG4,NAD,3042,,,,Straße und Hausnummer oderPostfach,X, - 162,Name und Anschrift Ansprechpartner Wechselprozesse,SG4,NAD,3164,,,,Ort,X, - 163,Name und Anschrift Ansprechpartner Wechselprozesse,SG4,NAD,3251,,,,Postleitzahl,M [2]S [3],"[2] Wenn der Code im DE3207 in der ""EDI@Energy Codeliste der europäischen Ländercodes"" in der Spalte ""PLZ vorhanden"" ein ""X"" enthält - [3] wenn vorhanden" - 164,Name und Anschrift Ansprechpartner Wechselprozesse,SG4,NAD,3207,,,,"Ländername, Code",X, - 165,Ansprechpartner,SG7,,,,,,,Muss, - 166,Ansprechpartner,SG7,CTA,,,,,,Muss, - 167,Ansprechpartner,SG7,CTA,3139,,IC,,Informationskontakt,X, - 168,Ansprechpartner,SG7,CTA,3412,,,,Name der organisatorischenEinheit,X [501],"[501] Hinweis: Es darf kein Name einer natürlichen Person übermittelt werden, stattdessen ist die" - 169,Kommunikationsverbindung,SG7,COM,,,,,,Muss, - 170,Kommunikationsverbindung,SG7,COM,3148,,,,Nummer / Adresse,X (([939][6])∨ ([940][8]))∧ [502],"[6] wenn im DE3155 im demselben COM der Code EM vorhanden ist - [8] wenn im DE3155 im demselben COM der Code TE / FX vorhanden ist - [502] Hinweis: Es darf nur eine Information im DE3148 übermittelt werden - [939] Format: Die Zeichenkette muss die Zeichen @ und . enthalten - [940] Format: Die Zeichenkette muss mit dem Zeichen + beginnen und danach dürfen nur noch Ziffern folgen" - 171,Kommunikationsverbindung,SG7,COM,3155,,EM,,Elektronische Post,X [1P1..1], - 172,Kommunikationsverbindung,SG7,COM,3155,,TE,,Telefon,X [1P1..1], - 173,Kommunikationsverbindung,SG7,COM,3155,,FX,,Telefax,X [1P0..1], - 174,Name und Anschrift Ansprechpartner Stammdatenprozesse,SG4,,,,,,,Muss [10],"[10] Wenn BGM DE1373 = 11 (Dokument nicht verfügbar) nicht vorhanden - [19] Wenn MP-ID in SG2 NAD+MR (Nachrichtenempfänger) in der Rolle LF/MSB/ NB/ÜNB" - 175,Name und Anschrift Ansprechpartner Stammdatenprozesse,SG4,NAD,,,,,,Muss, - 176,Name und Anschrift Ansprechpartner Stammdatenprozesse,SG4,NAD,3035,,Z14,,AnsprechpartnerStammdatenprozesse,X, - 177,Name und Anschrift Ansprechpartner Stammdatenprozesse,SG4,NAD,3036,,,,Name,X [500],[500] Hinweis: Es kann der Firmenname eines Dienstleisters oder die identische Firmenbezeichnung aus SG4 NAD+SU / DDM / DEB / Z31 / Z34 / Z35 / Z36 eingetragen werden. - 178,Name und Anschrift Ansprechpartner Stammdatenprozesse,SG4,NAD,3045,,Z02,,Struktur derFirmenbezeichnung,X, - 179,Name und Anschrift Ansprechpartner Stammdatenprozesse,SG4,NAD,3042,,,,Straße und Hausnummer oderPostfach,X, - 180,Name und Anschrift Ansprechpartner Stammdatenprozesse,SG4,NAD,3164,,,,Ort,X, - 181,Name und Anschrift Ansprechpartner Stammdatenprozesse,SG4,NAD,3251,,,,Postleitzahl,M [2]S [3],"[2] Wenn der Code im DE3207 in der ""EDI@Energy Codeliste der europäischen Ländercodes"" in der Spalte ""PLZ vorhanden"" ein ""X"" enthält - [3] wenn vorhanden" - 182,Name und Anschrift Ansprechpartner Stammdatenprozesse,SG4,NAD,3207,,,,"Ländername, Code",X, - 183,Ansprechpartner,SG7,,,,,,,Muss, - 184,Ansprechpartner,SG7,CTA,,,,,,Muss, - 185,Ansprechpartner,SG7,CTA,3139,,IC,,Informationskontakt,X, - 186,Ansprechpartner,SG7,CTA,3412,,,,Name der organisatorischenEinheit,X [501],"[501] Hinweis: Es darf kein Name einer natürlichen Person übermittelt werden, stattdessen ist die organisatorische Einheit im Unternehmen zu nennen." - 187,Kommunikationsverbindung,SG7,COM,,,,,,Muss, - 188,Kommunikationsverbindung,SG7,COM,3148,,,,Nummer / Adresse,X (([939][6])∨ ([940][8]))∧ [502],"[6] wenn im DE3155 im demselben COM der Code EM vorhanden ist - [8] wenn im DE3155 im demselben COM der Code TE / FX vorhanden ist - [502] Hinweis: Es darf" - 189,Kommunikationsverbindung,SG7,COM,3155,,EM,,Elektronische Post,X [1P1..1], - 190,Kommunikationsverbindung,SG7,COM,3155,,TE,,Telefon,X [1P1..1], - 191,Kommunikationsverbindung,SG7,COM,3155,,FX,,Telefax,X [1P0..1], - 192,Name und Anschrift Ansprechpartner Einspeiseprozesse,SG4,,,,,,,Muss [10] ∧[17],"[10] Wenn BGM DE1373 = 11 (Dokument nicht verfügbar) nicht vorhanden - [17] Wenn MP-ID in SG2 NAD+MR (Nachrichtenempfänger) in der Rolle LF/NB/MSB - [18] Wenn MP-ID in SG2 NAD+MR (Nachrichtenempfänger) in der Rolle LF/MSB - [23] Wenn MP-ID in SG2 NAD+MR (Nachrichtenempfänger) in der Rolle NB/ÜNB" - 193,Name und Anschrift Ansprechpartner Einspeiseprozesse,SG4,NAD,,,,,,Muss, - 194,Name und Anschrift Ansprechpartner Einspeiseprozesse,SG4,NAD,3035,,Z16,,AnsprechpartnerEinspeiseprozesse,X, - 195,Name und Anschrift Ansprechpartner Einspeiseprozesse,SG4,NAD,3036,,,,Name,X [500],[500] Hinweis: Es kann der Firmenname eines Dienstleisters oder die identische Firmenbezeichnung aus SG4 NAD+SU / DDM / DEB / Z31 / Z34 / Z35 / Z36 eingetragen werden. - 196,Name und Anschrift Ansprechpartner Einspeiseprozesse,SG4,NAD,3045,,Z02,,Struktur derFirmenbezeichnung,X, - 197,Name und Anschrift Ansprechpartner Einspeiseprozesse,SG4,NAD,3042,,,,Straße und Hausnummer oderPostfach,X, - 198,Name und Anschrift Ansprechpartner Einspeiseprozesse,SG4,NAD,3164,,,,Ort,X, - 199,Name und Anschrift Ansprechpartner Einspeiseprozesse,SG4,NAD,3251,,,,Postleitzahl,M [2]S [3],"[2] Wenn der Code im DE3207 in der ""EDI@Energy Codeliste der europäischen Ländercodes"" in der Spalte ""PLZ vorhanden"" ein ""X"" enthält - [3] wenn vorhanden" - 200,Name und Anschrift Ansprechpartner Einspeiseprozesse,SG4,NAD,3207,,,,"Ländername, Code",X, - 201,Ansprechpartner,SG7,,,,,,,Muss, - 202,Ansprechpartner,SG7,CTA,,,,,,Muss, - 203,Ansprechpartner,SG7,CTA,3139,,IC,,Informationskontakt,X, - 204,Ansprechpartner,SG7,CTA,3412,,,,Name der organisatorischenEinheit,X [501],"[501] Hinweis: Es darf kein Name einer natürlichen Person übermittelt werden, stattdessen ist die organisatorische Einheit im Unternehmen zu nennen." - 205,Kommunikationsverbindung,SG7,COM,,,,,,Muss, - 206,Kommunikationsverbindung,SG7,COM,3148,,,,Nummer / Adresse,X (([939][6])∨ ([940][8]))∧ [502],"[6] wenn im DE3155 im demselben COM der Code EM vorhanden ist - [8] wenn im DE3155 im demselben COM der Code TE / FX vorhanden ist - [502] Hinweis: Es darf nur eine Information im DE3148 übermittelt werden - [939] Format: Die Zeichenkette muss die Zeichen @ und . enthalten " - 207,Kommunikationsverbindung,SG7,COM,3155,,EM,,Elektronische Post,X [1P1..1], - 208,Kommunikationsverbindung,SG7,COM,3155,,TE,,Telefon,X [1P1..1], - 209,Kommunikationsverbindung,SG7,COM,3155,,FX,,Telefax,X [1P0..1], - 210,Name und Anschrift Ansprechpartner Abrechnungsprozesse,SG4,,,,,,,Muss [10] ∧[17],"[10] Wenn BGM DE1373 = 11 (Dokument nicht verfügbar) nicht vorhanden - [17] Wenn MP-ID in SG2 NAD+MR (Nachrichtenempfänger) in der Rolle LF/NB/MSB - [18] Wenn MP-ID in SG2 NAD+MR (Nachrichtenempfänger) in der Rolle LF/MSB - [24] Wenn MP-ID in SG2 NAD+MR (Nachrichtenempfänger) in der Rolle NB/LF/ MSB/ESA" - 211,Name und Anschrift Ansprechpartner Abrechnungsprozesse,SG4,NAD,,,,,,Muss, - 212,Name und Anschrift Ansprechpartner Abrechnungsprozesse,SG4,NAD,3035,,Z17,,AnsprechpartnerAbrechnungsprozesse,X, - 213,Name und Anschrift Ansprechpartner Abrechnungsprozesse,SG4,NAD,3036,,,,Name,X [500],[500] Hinweis: Es kann der Firmenname eines Dienstleisters oder die identische Firmenbezeichnung aus SG4 NAD+SU / DDM / DEB / Z31 / Z34 / Z35 / Z36 eingetragen werden. - 214,Name und Anschrift Ansprechpartner Abrechnungsprozesse,SG4,NAD,3045,,Z02,,Struktur derFirmenbezeichnung,X, - 215,Name und Anschrift Ansprechpartner Abrechnungsprozesse,SG4,NAD,3042,,,,Straße und Hausnummer oderPostfach,X, - 216,Name und Anschrift Ansprechpartner Abrechnungsprozesse,SG4,NAD,3164,,,,Ort,X, - 217,Name und Anschrift Ansprechpartner Abrechnungsprozesse,SG4,NAD,3251,,,,Postleitzahl,M [2]S [3],[2] Wenn der Code im DE3207 in der - 218,Name und Anschrift Ansprechpartner Abrechnungsprozesse,SG4,NAD,3207,,,,"Ländername, Code",X, - 219,Ansprechpartner,SG7,,,,,,,Muss, - 220,Ansprechpartner,SG7,CTA,,,,,,Muss, - 221,Ansprechpartner,SG7,CTA,3139,,IC,,Informationskontakt,X, - 222,Ansprechpartner,SG7,CTA,3412,,,,Name der organisatorischenEinheit,X [501],"[501] Hinweis: Es darf kein Name einer natürlichen Person übermittelt werden, stattdessen ist die organisatorische Einheit im Unternehmen zu nennen." - 223,Kommunikationsverbindung,SG7,COM,,,,,,Muss, - 224,Kommunikationsverbindung,SG7,COM,3148,,,,Nummer / Adresse,X (([939][6])∨ ([940][8]))∧ [502],"[6] wenn im DE3155 im demselben COM der Code EM vorhanden ist - [8] wenn im DE3155 im demselben COM der Code TE / FX vorhanden ist - [502] Hinweis: Es darf nur eine Information im DE3148 übermittelt werden - [939] Format: Die Zeichenkette muss die Zeichen @ und . enthalten - [940] Format: Die Zeichenkette muss mit dem Zeichen + beginnen und danach dürfen nur noch Ziffern folgen" - 225,Kommunikationsverbindung,SG7,COM,3155,,EM,,Elektronische Post,X [1P1..1], - 226,Kommunikationsverbindung,SG7,COM,3155,,TE,,Telefon,X [1P1..1], - 227,Name und Anschrift Ansprechpartner MMMA- Prozesse,SG4,,,,,,,Muss [10] ∧[17],"[10] Wenn BGM DE1373 = 11 (Dokument nicht verfügbar) nicht vorhanden - [17] Wenn MP-ID in SG2 NAD+MR (Nachrichtenempfänger) in der Rolle LF/NB/MSB - [20] Wenn MP-ID in SG2 NAD+MR (Nachrichtenempfänger) in der Rolle LF/MSB/ÜNB" - 228,Name und Anschrift Ansprechpartner MMMA- Prozesse,SG4,NAD,,,,,,Muss, - 229,Name und Anschrift Ansprechpartner MMMA- Prozesse,SG4,NAD,3035,,Z18,,AnsprechpartnerMMMA-Prozesse,X, - 230,Name und Anschrift Ansprechpartner MMMA- Prozesse,SG4,NAD,3036,,,,Name,X [500],[500] Hinweis: Es kann der Firmenname eines Dienstleisters oder die identische Firmenbezeichnung aus SG4 NAD+SU / DDM / DEB / Z31 / Z34 / Z35 / Z36 eingetragen werden. - 231,Name und Anschrift Ansprechpartner MMMA- Prozesse,SG4,NAD,3045,,Z02,,Struktur derFirmenbezeichnung,X, - 232,Name und Anschrift Ansprechpartner MMMA- Prozesse,SG4,NAD,3042,,,,Straße und Hausnummer oderPostfach,X, - 233,Name und Anschrift Ansprechpartner MMMA- Prozesse,SG4,NAD,3164,,,,Ort,X, - 234,Name und Anschrift Ansprechpartner MMMA- Prozesse,SG4,NAD,3251,,,,Postleitzahl,M [2]S [3],"[2] Wenn der Code im DE3207 in der ""EDI@Energy Codeliste der europäischen Ländercodes"" in der Spalte ""PLZ vorhanden"" ein ""X"" enthält - [3] wenn vorhanden" - 235,Name und Anschrift Ansprechpartner MMMA- Prozesse,SG4,NAD,3207,,,,"Ländername, Code",X, - 236,Ansprechpartner,SG7,,,,,,,Muss, - 237,Ansprechpartner,SG7,CTA,,,,,,Muss, - 238,Ansprechpartner,SG7,CTA,3139,,IC,,Informationskontakt,X, - 239,Ansprechpartner,SG7,CTA,3412,,,,Name der organisatorischenEinheit,X [501],"[501] Hinweis: Es darf kein Name einer natürlichen Person übermittelt werden, stattdessen ist die organisatorische Einheit im Unternehmen zu nennen." - 240,Kommunikationsverbindung,SG7,COM,,,,,,Muss, - 241,Kommunikationsverbindung,SG7,COM,3148,,,,Nummer / Adresse,X (([939][6])∨ ([940][8]))∧ [502],"[6] wenn im DE3155 im demselben COM der Code EM vorhanden ist - [8] wenn im DE3155 im demselben COM der Code TE / FX vorhanden ist - [502] Hinweis: Es darf nur eine Information im DE3148 übermittelt werden - [939] Format: Die Zeichenkette muss die Zeichen @ und . enthalten - [940] Format: Die Zeichenkette muss mit dem Zeichen + beginnen und danach dürfen nur noch Ziffern folgen" - 242,Kommunikationsverbindung,SG7,COM,3155,,EM,,Elektronische Post,X [1P1..1], - 243,Kommunikationsverbindung,SG7,COM,3155,,TE,,Telefon,X [1P1..1], - 244,Kommunikationsverbindung,SG7,COM,3155,,FX,,Telefax,X [1P0..1], - 245,Name und Anschrift Bewegungsdaten,SG4,,,,,,,Muss [10],"[10] Wenn BGM DE1373 = 11 (Dokument nicht verfügbar) nicht vorhanden - [19] Wenn MP-ID in SG2 NAD+MR (Nachrichtenempfänger) in der Rolle LF/MSB/" - 246,Name und Anschrift Bewegungsdaten,SG4,NAD,,,,,,Muss, - 247,Name und Anschrift Bewegungsdaten,SG4,NAD,3035,,Z19,,AnsprechpartnerBewegungsdaten,X, - 248,Name und Anschrift Bewegungsdaten,SG4,NAD,3036,,,,Name,X [500],[500] Hinweis: Es kann der Firmenname eines Dienstleisters oder die identische Firmenbezeichnung aus SG4 NAD+SU / DDM / DEB / Z31 / Z34 / Z35 / Z36 eingetragen werden. - 249,Name und Anschrift Bewegungsdaten,SG4,NAD,3045,,Z02,,Struktur derFirmenbezeichnung,X, - 250,Name und Anschrift Bewegungsdaten,SG4,NAD,3042,,,,Straße und Hausnummer oderPostfach,X, - 251,Name und Anschrift Bewegungsdaten,SG4,NAD,3164,,,,Ort,X, - 252,Name und Anschrift Bewegungsdaten,SG4,NAD,3251,,,,Postleitzahl,M [2]S [3],"[2] Wenn der Code im DE3207 in der ""EDI@Energy Codeliste der europäischen Ländercodes"" in der Spalte ""PLZ vorhanden"" ein ""X"" enthält - [3] wenn vorhanden" - 253,Name und Anschrift Bewegungsdaten,SG4,NAD,3207,,,,"Ländername, Code",X, - 254,Ansprechpartner,SG7,,,,,,,Muss, - 255,Ansprechpartner,SG7,CTA,,,,,,Muss, - 256,Ansprechpartner,SG7,CTA,3139,,IC,,Informationskontakt,X, - 257,Ansprechpartner,SG7,CTA,3412,,,,Name der organisatorischenEinheit,X [501],"[501] Hinweis: Es darf kein Name einer natürlichen Person übermittelt werden, stattdessen ist die organisatorische Einheit im Unternehmen zu nennen." - 258,Kommunikationsverbindung,SG7,COM,,,,,,Muss, - 259,Kommunikationsverbindung,SG7,COM,3148,,,,Nummer / Adresse,X (([939][6])∨ ([940][8]))∧ [502],"[6] wenn im DE3155 im demselben COM der Code EM vorhanden ist - [8] wenn im DE3155 im demselben COM der" - 260,Kommunikationsverbindung,SG7,COM,3155,,EM,,Elektronische Post,X [1P1..1], - 261,Kommunikationsverbindung,SG7,COM,3155,,TE,,Telefon,X [1P1..1], - 262,Kommunikationsverbindung,SG7,COM,3155,,FX,,Telefax,X [1P0..1], - 263,Name und Anschrift Ansprechpartner Prozesse zur Unterbrechung und Wiederherstellung der Anschlussnutzung,SG4,,,,,,,Muss [10] ∧[17],"[10] Wenn BGM DE1373 = 11 (Dokument nicht verfügbar) nicht vorhanden - [17] Wenn MP-ID in SG2 NAD+MR (Nachrichtenempfänger) in der Rolle LF/NB/MSB - [20] Wenn MP-ID in SG2 NAD+MR (Nachrichtenempfänger) in der Rolle LF/MSB/ÜNB" - 264,Name und Anschrift Ansprechpartner Prozesse zur Unterbrechung und Wiederherstellung der Anschlussnutzung,SG4,NAD,,,,,,Muss, - 265,Name und Anschrift Ansprechpartner Prozesse zur Unterbrechung und Wiederherstellung der Anschlussnutzung,SG4,NAD,3035,,Z20,,AnsprechpartnerSperr-/Entsperrprozesse,X, - 266,Name und Anschrift Ansprechpartner Prozesse zur Unterbrechung und Wiederherstellung der Anschlussnutzung,SG4,NAD,3036,,,,Name,X [500],[500] Hinweis: Es kann der Firmenname eines Dienstleisters oder die identische Firmenbezeichnung aus SG4 NAD+SU / DDM / DEB / Z31 / Z34 / Z35 / - 267,Name und Anschrift Ansprechpartner Prozesse zur Unterbrechung und Wiederherstellung der Anschlussnutzung,SG4,NAD,3045,,Z02,,Struktur derFirmenbezeichnung,X, - 268,Name und Anschrift Ansprechpartner Prozesse zur Unterbrechung und Wiederherstellung der Anschlussnutzung,SG4,NAD,3042,,,,Straße und Hausnummer oderPostfach,X, - 269,Name und Anschrift Ansprechpartner Prozesse zur Unterbrechung und Wiederherstellung der Anschlussnutzung,SG4,NAD,3164,,,,Ort,X, - 270,Name und Anschrift Ansprechpartner Prozesse zur Unterbrechung und Wiederherstellung der Anschlussnutzung,SG4,NAD,3251,,,,Postleitzahl,M [2]S [3],"[2] Wenn der Code im DE3207 in der ""EDI@Energy Codeliste der europäischen Ländercodes"" in der Spalte ""PLZ vorhanden"" ein ""X"" enthält - [3] wenn vorhanden" - 271,Name und Anschrift Ansprechpartner Prozesse zur Unterbrechung und Wiederherstellung der Anschlussnutzung,SG4,NAD,3207,,,,"Ländername, Code",X, - 272,Ansprechpartner,SG7,,,,,,,Muss, - 273,Ansprechpartner,SG7,CTA,,,,,,Muss, - 274,Ansprechpartner,SG7,CTA,3139,,IC,,Informationskontakt,X, - 275,Ansprechpartner,SG7,CTA,3412,,,,Name der organisatorischenEinheit,X [501],"[501] Hinweis: Es darf kein Name einer natürlichen Person übermittelt werden, stattdessen ist die organisatorische Einheit im Unternehmen zu nennen." - 276,Kommunikationsverbindung,SG7,COM,,,,,,Muss, - 277,Kommunikationsverbindung,SG7,COM,3148,,,,Nummer / Adresse,X (([939][6])∨ ([940][8]))∧ [502],"[6] wenn im DE3155 im demselben COM der Code EM vorhanden ist - [8] wenn im DE3155 im demselben COM der Code TE / FX vorhanden ist - [502] Hinweis: Es darf nur eine Information im DE3148 übermittelt werden - [939] Format: Die Zeichenkette muss die Zeichen @ und ." - 278,Kommunikationsverbindung,SG7,COM,3155,,EM,,Elektronische Post,X [1P1..1], - 279,Kommunikationsverbindung,SG7,COM,3155,,TE,,Telefon,X [1P1..1], - 280,Kommunikationsverbindung,SG7,COM,3155,,FX,,Telefax,X [1P0..1], - 281,Name und Anschrift Ansprechpartner Bilanzierungsprozesse / Bilanzkreismanagement,SG4,,,,,,,Muss [10],[10] Wenn BGM DE1373 = 11 (Dokument nicht verfügbar) nicht vorhanden - 282,Name und Anschrift Ansprechpartner Bilanzierungsprozesse / Bilanzkreismanagement,SG4,NAD,,,,,,Muss, - 283,Name und Anschrift Ansprechpartner Bilanzierungsprozesse / Bilanzkreismanagement,SG4,NAD,3035,,Z21,,AnsprechpartnerBilanzierungsprozesse /Bilanzkreismanagement,X, - 284,Name und Anschrift Ansprechpartner Bilanzierungsprozesse / Bilanzkreismanagement,SG4,NAD,3036,,,,Name,X [500],[500] Hinweis: Es kann der Firmenname eines Dienstleisters oder die identische Firmenbezeichnung aus SG4 NAD+SU / DDM / DEB / Z31 / Z34 / Z35 / Z36 eingetragen werden. - 285,Name und Anschrift Ansprechpartner Bilanzierungsprozesse / Bilanzkreismanagement,SG4,NAD,3045,,Z02,,Struktur derFirmenbezeichnung,X, - 286,Name und Anschrift Ansprechpartner Bilanzierungsprozesse / Bilanzkreismanagement,SG4,NAD,3042,,,,Straße und Hausnummer oderPostfach,X, - 287,Name und Anschrift Ansprechpartner Bilanzierungsprozesse / Bilanzkreismanagement,SG4,NAD,3164,,,,Ort,X, - 288,Name und Anschrift Ansprechpartner Bilanzierungsprozesse / Bilanzkreismanagement,SG4,NAD,3251,,,,Postleitzahl,M [2]S [3],"[2] Wenn der Code im DE3207 in der ""EDI@Energy Codeliste der europäischen Ländercodes"" in der Spalte ""PLZ vorhanden"" ein ""X"" enthält - [3] wenn vorhanden" - 289,Name und Anschrift Ansprechpartner Bilanzierungsprozesse / Bilanzkreismanagement,SG4,NAD,3207,,,,"Ländername, Code",X, - 290,Ansprechpartner,SG7,,,,,,,Muss, - 291,Ansprechpartner,SG7,CTA,,,,,,Muss, - 292,Ansprechpartner,SG7,CTA,3139,,IC,,Informationskontakt,X, - 293,Ansprechpartner,SG7,CTA,3412,,,,Name der organisatorischenEinheit,X [501],"[501] Hinweis: Es darf kein Name einer natürlichen Person übermittelt werden, stattdessen ist die organisatorische Einheit im Unternehmen zu nennen." - 294,Kommunikationsverbindung,SG7,COM,,,,,,Muss, - 295,Kommunikationsverbindung,SG7,COM,3148,,,,Nummer / Adresse,X (([939][6])∨ ([940][8]))∧ [502],"[6] wenn im DE3155 im demselben COM der Code EM vorhanden ist - [8] wenn im DE3155 im demselben COM der Code TE / FX vorhanden ist - [502] Hinweis: Es darf nur eine Information im DE3148 übermittelt werden - [939] Format: Die Zeichenkette muss die Zeichen @ und . enthalten - [940] Format: Die Zeichenkette muss mit dem Zeichen + beginnen und danach dürfen nur noch Ziffern folgen" - 296,Kommunikationsverbindung,SG7,COM,3155,,EM,,Elektronische Post,X [1P1..1], - 297,Kommunikationsverbindung,SG7,COM,3155,,TE,,Telefon,X [1P1..1], - 298,Kommunikationsverbindung,SG7,COM,3155,,FX,,Telefax,X [1P0..1], - 299,Name und Anschrift Ansprechpartner Technischer Netzanschluss für Neuanlagen und Anlagenumbau,SG4,,,,,,,,[10] Wenn BGM DE1373 = 11 (Dokument nicht verfügbar) nicht vorhanden - 300,Name und Anschrift Ansprechpartner Technischer Netzanschluss für Neuanlagen und Anlagenumbau,SG4,NAD,,,,,,, - 301,Name und Anschrift Ansprechpartner Technischer Netzanschluss für Neuanlagen und Anlagenumbau,SG4,NAD,3035,,Z33,,AnsprechpartnertechnischerNetzanschluss fürNeuanlagen undAnlagenumbau,, - 302,Name und Anschrift Ansprechpartner Technischer Netzanschluss für Neuanlagen und Anlagenumbau,SG4,NAD,3036,,,,Name,,[500] Hinweis: Es kann der Firmenname eines Dienstleisters oder die identische Firmenbezeichnung aus SG4 NAD+SU / DDM / DEB / Z31 / Z34 / Z35 / Z36 eingetragen werden. - 303,Name und Anschrift Ansprechpartner Technischer Netzanschluss für Neuanlagen und Anlagenumbau,SG4,NAD,3045,,Z02,,Struktur derFirmenbezeichnung,, - 304,Name und Anschrift Ansprechpartner Technischer Netzanschluss für Neuanlagen und Anlagenumbau,SG4,NAD,3042,,,,Straße und Hausnummer oderPostfach,, - 305,Name und Anschrift Ansprechpartner Technischer Netzanschluss für Neuanlagen und Anlagenumbau,SG4,NAD,3164,,,,Ort,, - 306,Name und Anschrift Ansprechpartner Technischer Netzanschluss für Neuanlagen und Anlagenumbau,SG4,NAD,3251,,,,Postleitzahl,,"[2] Wenn der Code im DE3207 in der ""EDI@Energy Codeliste der europäischen Ländercodes"" in der Spalte ""PLZ vorhanden"" ein ""X"" enthält - [3] wenn vorhanden" - 307,Name und Anschrift Ansprechpartner Technischer Netzanschluss für Neuanlagen und Anlagenumbau,SG4,NAD,3207,,,,"Ländername, Code",, - 308,Ansprechpartner,SG7,,,,,,,, - 309,Ansprechpartner,SG7,CTA,,,,,,, - 310,Ansprechpartner,SG7,CTA,3139,,IC,,Informationskontakt,, - 311,Ansprechpartner,SG7,CTA,3412,,,,Name der organisatorischenEinheit,,"[501] Hinweis: Es darf kein Name einer natürlichen Person übermittelt werden, stattdessen ist die organisatorische Einheit im Unternehmen zu nennen." - 312,Kommunikationsverbindung,SG7,COM,,,,,,, - 313,Kommunikationsverbindung,SG7,COM,3148,,,,Nummer / Adresse,,"[6] wenn im DE3155 im demselben COM der Code EM vorhanden ist - [8] wenn im DE3155 im demselben COM der Code TE / FX vorhanden ist - [502] Hinweis: Es darf nur eine Information im DE3148 übermittelt werden - [939] Format: Die Zeichenkette muss die Zeichen @ und . enthalten - [940] Format: Die Zeichenkette muss mit dem Zeichen + beginnen und danach dürfen nur noch Ziffern folgen" - 314,Kommunikationsverbindung,SG7,COM,3155,,EM,,Elektronische Post,, - 315,Kommunikationsverbindung,SG7,COM,3155,,TE,,Telefon,, - 316,Kommunikationsverbindung,SG7,COM,3155,,FX,,Telefax,, - 317,Nachrichten-Endesegment,,UNT,,,,,,Muss, - 318,Nachrichten-Endesegment,,UNT,0074,,,,Anzahl der Segmente in einerNachricht,X, - 319,Nachrichten-Endesegment,,UNT,0062,,,,Nachrichten-Referenznummer,X, - - ''', - '37001.csv': ''' - ,Segmentname,Segmentgruppe,Segment,Datenelement,Segment ID,Code,Qualifier,Beschreibung,Bedingungsausdruck,Bedingung - 0,Nachrichten-Kopfsegment,,UNH,,,,,,Muss, - 1,Nachrichten-Kopfsegment,,UNH,0062,,,,Nachrichten-Referenznummer,X, - 2,Nachrichten-Kopfsegment,,UNH,0065,,PARTIN,,Partnerstammdaten,X, - 3,Nachrichten-Kopfsegment,,UNH,0052,,D,,Entwurfs-Version,X, - 4,Nachrichten-Kopfsegment,,UNH,0054,,20B,,Ausgabe 2020 - B,X, - 5,Nachrichten-Kopfsegment,,UNH,0051,,UN,,UN/CEFACT,X, - 6,Nachrichten-Kopfsegment,,UNH,0057,,1.0c,,Versionsnummer derzugrundeliegendenBDEW-Nachrichtenbeschreibung,X, - 7,Beginn der Nachricht,,BGM,,,,,,Muss, - 8,Beginn der Nachricht,,BGM,1001,,10,,Partnerstammdaten,X, - 9,Beginn der Nachricht,,BGM,1004,,,,Dokumentennummer,X, - 10,Beginn der Nachricht,,BGM,1373,,11,,Dokument nichtverfügbar,S [9],[9] Wenn die Kommunikationsdaten vom Absender nicht mehr aktiv sind. - 11,Nachrichtendatum,,DTM,,,,,,Muss, - 12,Nachrichtendatum,,DTM,2005,,137,,Dokumenten-/Nachrichtendatum/-zeit,X, - 13,Nachrichtendatum,,DTM,2380,,,,"Datum oder Uhrzeit oderZeitspanne, Wert",X [931][494],"[494] Das hier genannte Datum muss der Zeitpunkt sein, zu dem das Dokument erstellt wurde, oder ein Zeitpunkt, der davor liegt. - [931] Format: ZZZ = +00" - 14,Nachrichtendatum,,DTM,2379,,303,,CCYYMMDDHHMMZZZ,X, - 15,Prüfidentifikator,SG1,,,,,,,Muss, - 16,Prüfidentifikator,SG1,RFF,,,,,,Muss, - 17,Prüfidentifikator,SG1,RFF,1153,,Z13,,Prüfidentifikator,X, - 18,Prüfidentifikator,SG1,RFF,1154,,37000,,ÜbermittlungKommunikationsdatendes LF,, - 19,Prüfidentifikator,SG1,RFF,1154,,37001,,ÜbermittlungKommunikationsdatendes NB,X, - 20,Prüfidentifikator,SG1,RFF,1154,,37002,,ÜbermittlungKommunikationsdatendes MSB,, - 21,Versionsnummer,SG1,,,,,,,Muss, - 22,Versionsnummer,SG1,RFF,,,,,,Muss, - 23,Versionsnummer,SG1,RFF,1153,,AGK,,Anwendungsreferenznummer,X, - 24,Versionsnummer,SG1,RFF,1056,,,,Versionsnummer,X [908][505],"[505] Wenn eine Vorgängerversion (RFF+ACW) angegeben ist, so muss der Wert in diesem DE1056 mindestens um 1 höher sein, als der Wert aus DE1056 der Vorgängerversion (RFF+ACW). - [908] Format: Mögliche Werte: 1 bis n" - 25,Gültig Ab,SG1,DTM,,,,,,Soll [4],[4] Wenn Vorgängerversion vorhanden - 26,Gültig Ab,SG1,DTM,2005,,157,,"Gültigkeit, Beginndatum",X, - 27,Gültig Ab,SG1,DTM,2380,,,,"Datum oder Uhrzeit oderZeitspanne, Wert",X [UB1], - 28,Gültig Ab,SG1,DTM,2379,,303,,CCYYMMDDHHMMZZZ,X, - 29,Vorgängerversion,SG1,,,,,,,Soll [4],[4] Wenn Vorgängerversion vorhanden - 30,Vorgängerversion,SG1,RFF,,,,,,Muss, - 31,Vorgängerversion,SG1,RFF,1153,,ACW,,Referenznummer einervorangegangenenNachricht,X, - 32,Vorgängerversion,SG1,RFF,1056,,,,Versionsnummer,X [908],[908] Format: Mögliche Werte: 1 bis n - 33,MP-ID Absender,SG2,,,,,,,Muss, - 34,MP-ID Absender,SG2,NAD,,,,,,Muss, - 35,MP-ID Absender,SG2,NAD,3035,,MS,,Dokumenten-/Nachrichtenausstellerbzw. -absender,X, - 36,MP-ID Absender,SG2,NAD,3039,,,,MP-ID,X [1],[1] Nur MP-ID aus Sparte Strom - 37,MP-ID Absender,SG2,NAD,3055,,9,,GS1,X, - 38,MP-ID Absender,SG2,NAD,3055,,293,,"DE, BDEW",X, - 39,Ansprechpartner,SG3,,,,,,,Kann, - 40,Ansprechpartner,SG3,CTA,,,,,,Muss, - 41,Ansprechpartner,SG3,CTA,3139,,IC,,Informationskontakt,X, - 42,Ansprechpartner,SG3,CTA,3412,,,,Name vom Ansprechpartner,X, - 43,Kommunikationsverbindung,SG3,COM,,,,,,Muss, - 44,Kommunikationsverbindung,SG3,COM,3148,,,,Nummer / Adresse,X (([939][6])∨ ([940][7]))∧ [502],"[6] wenn im DE3155 im demselben COM der Code EM vorhanden ist - [7] wenn im DE3155 im demselben COM der Code TE / FX / AJ / AL vorhanden ist - [502] Hinweis: Es darf nur eine Information im DE3148 übermittelt werden - [939] Format: Die Zeichenkette muss die Zeichen @ und . enthalten - [940] Format: Die Zeichenkette muss mit dem Zeichen + beginnen und danach dürfen nur noch Ziffern folgen" - 45,Kommunikationsverbindung,SG3,COM,3155,,EM,,Elektronische Post,X [1P0..1], - 46,Kommunikationsverbindung,SG3,COM,3155,,FX,,Telefax,X [1P0..1], - 47,Kommunikationsverbindung,SG3,COM,3155,,TE,,Telefon,X [1P0..1], - 48,Kommunikationsverbindung,SG3,COM,3155,,AJ,,weiteres Telefon,X [1P0..1], - 49,Kommunikationsverbindung,SG3,COM,3155,,AL,,Handy,X [1P0..1], - 50,MP-ID Empfänger,SG2,,,,,,,Muss, - 51,MP-ID Empfänger,SG2,NAD,,,,,,Muss, - 52,MP-ID Empfänger,SG2,NAD,3035,,MR,,Nachrichtenempfänger,X, - 53,MP-ID Empfänger,SG2,NAD,3039,,,,MP-ID,X [1],[1] Nur MP-ID aus Sparte Strom - 54,MP-ID Empfänger,SG2,NAD,3055,,9,,GS1,X, - 55,MP-ID Empfänger,SG2,NAD,3055,,293,,"DE, BDEW",X, - 56,Abschnitts-Kontrollsegment,,UNS,,,,,,Muss, - 57,Abschnitts-Kontrollsegment,,UNS,0081,,D,,Trennung von Kopf- undPositionsteil,X, - 58,Name und Adresse des Unternehmens,SG4,,,,,,,Muss [10],[10] Wenn BGM DE1373 = 11 (Dokument nicht verfügbar) nicht vorhanden - 59,Name und Adresse des Unternehmens,SG4,NAD,,,,,,Muss, - 60,Name und Adresse des Unternehmens,SG4,NAD,3035,,SU,,Lieferant,, - 61,Name und Adresse des Unternehmens,SG4,NAD,3035,,DDM,,Netzbetreiber,X, - 62,Name und Adresse des Unternehmens,SG4,NAD,3035,,DEB,,Messstellenbetreiber,, - 63,Name und Adresse des Unternehmens,SG4,NAD,3036,,,,Name,X [506],"[506] Hinweis: Das Datenelement ist so zu füllen, dass sein Inhalt den Vorgaben des USt.- Gesetzes genügt, so dass der Empfänger diese Daten in einer INVOIC nutzen kann." - 64,Name und Adresse des Unternehmens,SG4,NAD,3045,,Z02,,Struktur derFirmenbezeichnung,X, - 65,Name und Adresse des Unternehmens,SG4,NAD,3042,,,,Straße und Hausnummer oderPostfach,X [506],"[506] Hinweis: Das Datenelement ist so zu füllen, dass sein Inhalt den Vorgaben des USt.- Gesetzes genügt, so dass der Empfänger diese Daten in einer INVOIC nutzen kann." - 66,Name und Adresse des Unternehmens,SG4,NAD,3164,,,,Ort,X [506],"[506] Hinweis: Das Datenelement ist so zu füllen, dass sein Inhalt den Vorgaben des USt.- Gesetzes genügt, so dass der Empfänger diese Daten in einer INVOIC nutzen kann." - 67,Name und Adresse des Unternehmens,SG4,NAD,3251,,,,Postleitzahl,M [2] ∧[506]S [3] ∧ [506],"[2] Wenn der Code im DE3207 in der ""EDI@Energy Codeliste der europäischen Ländercodes"" in der Spalte ""PLZ vorhanden""" - 68,Name und Adresse des Unternehmens,SG4,NAD,3207,,,,"Ländername, Code",X [506],"[506] Hinweis: Das Datenelement ist so zu füllen, dass sein Inhalt den Vorgaben des USt.- Gesetzes genügt, so dass der Empfänger diese Daten in einer INVOIC nutzen kann." - 69,Bankverbindung,SG4,FII,,,,,,Muss, - 70,Bankverbindung,SG4,FII,3035,,BK,,Kreditinstitut,X, - 71,Bankverbindung,SG4,FII,3194,,IBAN,,,X, - 72,Bankverbindung,SG4,FII,3192,,,,Name des Kontoinhabers,X, - 73,Bankverbindung,SG4,FII,3192,,,,Name des Kontoinhabers,K, - 74,Bankverbindung,SG4,FII,3433,,BIC,,,X, - 75,Bankverbindung,SG4,FII,3432,,,,Name des Kredinstituts,X, - 76,Internetseite (URL),SG4,FTX,,,,,,Muss, - 77,Internetseite (URL),SG4,FTX,4451,,Z13,,Internetseite,X, - 78,Internetseite (URL),SG4,FTX,4440,,,,Internetseite,X, - 79,Gericht und Handelsregister-Nummer,SG4,FTX,,,,,,Soll [3],[3] wenn vorhanden - 80,Gericht und Handelsregister-Nummer,SG4,FTX,4451,,Z15,,Gericht undHandelsregister-Nummer,X, - 81,Gericht und Handelsregister-Nummer,SG4,FTX,4440,,,,Gericht,X, - 82,Gericht und Handelsregister-Nummer,SG4,FTX,4440,,,,Handelsregister-Nummer,X, - 83,"Steuernummer, Umsatzsteuernummer",SG6,,,,,,,Muss [504],[504] Hinweis: Es ist mindestens die - 84,"Steuernummer, Umsatzsteuernummer",SG6,RFF,,,,,,Muss, - 85,"Steuernummer, Umsatzsteuernummer",SG6,RFF,1153,,VA,,Umsatzsteuernummer,X [2P0..1] ⊻[3P1..1], - 86,"Steuernummer, Umsatzsteuernummer",SG6,RFF,1153,,FC,,Steuernummer,X [2P0..1], - 87,"Steuernummer, Umsatzsteuernummer",SG6,RFF,1154,,,,"Referenz, Identifikation",X, - 88,Faxnummer,SG6,RFF,,,,,,Kann, - 89,Faxnummer,SG6,RFF,1153,,Z25,,Faxnummer,X, - 90,Faxnummer,SG6,RFF,1154,,,,Faxnummer,X [940],[940] Format: Die Zeichenkette muss mit dem Zeichen + beginnen und danach dürfen nur noch Ziffern folgen - 91,Erreichbarkeit an Werktagen,SG12,,,,,,,Muss, - 92,Erreichbarkeit an Werktagen,SG12,CCI,,,,,,Muss, - 93,Erreichbarkeit an Werktagen,SG12,CCI,7059,,Z40,,Erreichbarkeit desUnternehmens,X, - 94,Erreichbarkeit,SG12,DTM,,,,,,Muss, - 95,Erreichbarkeit,SG12,DTM,2005,,Z36,,Verfügbarkeit Montag,X [1P1..1], - 96,Erreichbarkeit,SG12,DTM,2005,,Z37,,Verfügbarkeit Dienstag,X [1P1..1], - 97,Erreichbarkeit,SG12,DTM,2005,,Z38,,Verfügbarkeit Mittwoch,X [1P1..1], - 98,Erreichbarkeit,SG12,DTM,2005,,Z39,,VerfügbarkeitDonnerstag,X [1P1..1], - 99,Erreichbarkeit,SG12,DTM,2005,,Z40,,Verfügbarkeit Freitag,X [1P1..1], - 100,Erreichbarkeit,SG12,DTM,2005,,Z41,,Mittagspause (=Ausschluss derVerfügbarkeit),X [1P0..1], - 101,Erreichbarkeit,SG12,DTM,2380,,,,"Datum oder Uhrzeit oderZeitspanne, Wert",X [503],[503] Hinweis: Angabe erfolgt in gesetzlicher deutscher Zeit - 102,Erreichbarkeit,SG12,DTM,2379,,501,,HHMMHHMM,X, - 103,Name und Anschrift Ansprechpartner Übertragungsweg / Datenaustausch,SG4,,,,,,,Muss [10],[10] Wenn BGM DE1373 = 11 (Dokument nicht verfügbar) nicht - 104,Name und Anschrift Ansprechpartner Übertragungsweg / Datenaustausch,SG4,NAD,,,,,,Muss, - 105,Name und Anschrift Ansprechpartner Übertragungsweg / Datenaustausch,SG4,NAD,3035,,Z10,,AnsprechpartnerÜbertragungsweg /Datenaustausch,X, - 106,Name und Anschrift Ansprechpartner Übertragungsweg / Datenaustausch,SG4,NAD,3036,,,,Name,X [500],[500] Hinweis: Es kann der Firmenname eines Dienstleisters oder die identische Firmenbezeichnung aus SG4 NAD+SU / DDM / DEB / Z31 / Z34 / Z35 / Z36 eingetragen werden. - 107,Name und Anschrift Ansprechpartner Übertragungsweg / Datenaustausch,SG4,NAD,3045,,Z02,,Struktur derFirmenbezeichnung,X, - 108,Name und Anschrift Ansprechpartner Übertragungsweg / Datenaustausch,SG4,NAD,3042,,,,Straße und Hausnummer oderPostfach,X, - 109,Name und Anschrift Ansprechpartner Übertragungsweg / Datenaustausch,SG4,NAD,3164,,,,Ort,X, - 110,Name und Anschrift Ansprechpartner Übertragungsweg / Datenaustausch,SG4,NAD,3251,,,,Postleitzahl,M [2]S [3],"[2] Wenn der Code im DE3207 in der ""EDI@Energy Codeliste der europäischen Ländercodes"" in der Spalte ""PLZ vorhanden"" ein ""X"" enthält - [3] wenn vorhanden" - 111,Name und Anschrift Ansprechpartner Übertragungsweg / Datenaustausch,SG4,NAD,3207,,,,"Ländername, Code",X, - 112,Ansprechpartner,SG7,,,,,,,Muss, - 113,Ansprechpartner,SG7,CTA,,,,,,Muss, - 114,Ansprechpartner,SG7,CTA,3139,,IC,,Informationskontakt,X, - 115,Ansprechpartner,SG7,CTA,3412,,,,Name der organisatorischenEinheit,X [501],"[501] Hinweis: Es darf kein Name einer natürlichen Person übermittelt werden, stattdessen ist die organisatorische Einheit im Unternehmen zu nennen." - 116,Kommunikationsverbindung,SG7,COM,,,,,,Muss, - 117,Kommunikationsverbindung,SG7,COM,3148,,,,Nummer / Adresse,X (([939][6])∨ ([940][8]))∧ [502],"[6] wenn im DE3155 im demselben COM der Code EM vorhanden ist - [8] wenn im DE3155 im" - 118,Kommunikationsverbindung,SG7,COM,3155,,EM,,Elektronische Post,X [1P1..1], - 119,Kommunikationsverbindung,SG7,COM,3155,,TE,,Telefon,X [1P1..1], - 120,Kommunikationsverbindung,SG7,COM,3155,,FX,,Telefax,X [1P0..1], - 121,Name und Anschrift Ansprechpartner Rahmenverträge,SG4,,,,,,,Muss [10] ∧[18],"[10] Wenn BGM DE1373 = 11 (Dokument nicht verfügbar) nicht vorhanden - [17] Wenn MP-ID in SG2 NAD+MR (Nachrichtenempfänger) in der Rolle LF/NB/MSB - [18] Wenn MP-ID in SG2 NAD+MR (Nachrichtenempfänger) in der Rolle LF/MSB - [21] Wenn MP-ID in SG2 NAD+MR (Nachrichtenempfänger) in der Rolle LF/NB/ESA" - 122,Name und Anschrift Ansprechpartner Rahmenverträge,SG4,NAD,,,,,,Muss, - 123,Name und Anschrift Ansprechpartner Rahmenverträge,SG4,NAD,3035,,Z11,,AnsprechpartnerRahmenverträge,X, - 124,Name und Anschrift Ansprechpartner Rahmenverträge,SG4,NAD,3036,,,,Name,X [500],[500] Hinweis: Es kann der Firmenname eines Dienstleisters oder die - 125,Name und Anschrift Ansprechpartner Rahmenverträge,SG4,NAD,3045,,Z02,,Struktur derFirmenbezeichnung,X, - 126,Name und Anschrift Ansprechpartner Rahmenverträge,SG4,NAD,3042,,,,Straße und Hausnummer oderPostfach,X, - 127,Name und Anschrift Ansprechpartner Rahmenverträge,SG4,NAD,3164,,,,Ort,X, - 128,Name und Anschrift Ansprechpartner Rahmenverträge,SG4,NAD,3251,,,,Postleitzahl,M [2]S [3],"[2] Wenn der Code im DE3207 in der ""EDI@Energy Codeliste der europäischen Ländercodes"" in der Spalte ""PLZ vorhanden"" ein ""X"" enthält - [3] wenn vorhanden" - 129,Name und Anschrift Ansprechpartner Rahmenverträge,SG4,NAD,3207,,,,"Ländername, Code",X, - 130,Ansprechpartner,SG7,,,,,,,Muss, - 131,Ansprechpartner,SG7,CTA,,,,,,Muss, - 132,Ansprechpartner,SG7,CTA,3139,,IC,,Informationskontakt,X, - 133,Ansprechpartner,SG7,CTA,3412,,,,Name der organisatorischenEinheit,X [501],"[501] Hinweis: Es darf kein Name einer natürlichen Person übermittelt werden, stattdessen ist die organisatorische Einheit im Unternehmen zu nennen." - 134,Kommunikationsverbindung,SG7,COM,,,,,,Muss, - 135,Kommunikationsverbindung,SG7,COM,3148,,,,Nummer / Adresse,X (([939][6])∨ ([940][8]))∧ [502],"[6] wenn im DE3155 im demselben COM der Code EM vorhanden ist - [8] wenn im DE3155 im demselben COM der Code TE / FX vorhanden ist - [502] Hinweis: Es darf nur eine Information im DE3148 übermittelt werden" - 136,Kommunikationsverbindung,SG7,COM,3155,,EM,,Elektronische Post,X [1P1..1], - 137,Kommunikationsverbindung,SG7,COM,3155,,TE,,Telefon,X [1P1..1], - 138,Kommunikationsverbindung,SG7,COM,3155,,FX,,Telefax,X [1P0..1], - 139,Name und Anschrift Ansprechpartner Kündigungsprozess,SG4,,,,,,,,"[5] Wenn MP-ID in SG2 NAD+MR (Nachrichtenempfänger) in der Rolle LF - [10] Wenn BGM DE1373 = 11 (Dokument nicht verfügbar) nicht vorhanden - [22] Wenn MP-ID in SG2 NAD+MR (Nachrichtenempfänger) in der Rolle MSB" - 140,Name und Anschrift Ansprechpartner Kündigungsprozess,SG4,NAD,,,,,,, - 141,Name und Anschrift Ansprechpartner Kündigungsprozess,SG4,NAD,3035,,Z12,,AnsprechpartnerKündigungsprozesse,, - 142,Name und Anschrift Ansprechpartner Kündigungsprozess,SG4,NAD,3036,,,,Name,,[500] Hinweis: Es kann der Firmenname eines Dienstleisters oder die identische Firmenbezeichnung aus SG4 NAD+SU / DDM / DEB / Z31 / Z34 / Z35 / Z36 eingetragen werden. - 143,Name und Anschrift Ansprechpartner Kündigungsprozess,SG4,NAD,3045,,Z02,,Struktur derFirmenbezeichnung,, - 144,Name und Anschrift Ansprechpartner Kündigungsprozess,SG4,NAD,3042,,,,Straße und Hausnummer oderPostfach,, - 145,Name und Anschrift Ansprechpartner Kündigungsprozess,SG4,NAD,3164,,,,Ort,, - 146,Name und Anschrift Ansprechpartner Kündigungsprozess,SG4,NAD,3251,,,,Postleitzahl,,[2] Wenn der Code im DE3207 in der - 147,Name und Anschrift Ansprechpartner Kündigungsprozess,SG4,NAD,3207,,,,"Ländername, Code",, - 148,Ansprechpartner,SG7,,,,,,,, - 149,Ansprechpartner,SG7,CTA,,,,,,, - 150,Ansprechpartner,SG7,CTA,3139,,IC,,Informationskontakt,, - 151,Ansprechpartner,SG7,CTA,3412,,,,Name der organisatorischenEinheit,,"[501] Hinweis: Es darf kein Name einer natürlichen Person übermittelt werden, stattdessen ist die organisatorische Einheit im Unternehmen zu nennen." - 152,Kommunikationsverbindung,SG7,COM,,,,,,, - 153,Kommunikationsverbindung,SG7,COM,3148,,,,Nummer / Adresse,,"[6] wenn im DE3155 im demselben COM der Code EM vorhanden ist - [8] wenn im DE3155 im demselben COM der Code TE / FX vorhanden ist - [502] Hinweis: Es darf nur eine Information im DE3148 übermittelt werden - [939] Format: Die Zeichenkette muss die Zeichen @ und . enthalten - [940] Format: Die Zeichenkette muss mit dem Zeichen + beginnen und danach dürfen nur noch Ziffern folgen" - 154,Kommunikationsverbindung,SG7,COM,3155,,EM,,Elektronische Post,, - 155,Kommunikationsverbindung,SG7,COM,3155,,TE,,Telefon,, - 156,Name und Anschrift Ansprechpartner Wechselprozesse,SG4,,,,,,,Muss [10] ∧[17],"[10] Wenn BGM DE1373 = 11 (Dokument nicht verfügbar) nicht vorhanden - [17] Wenn MP-ID in SG2 NAD+MR (Nachrichtenempfänger) in der Rolle LF/NB/MSB" - 157,Name und Anschrift Ansprechpartner Wechselprozesse,SG4,NAD,,,,,,Muss, - 158,Name und Anschrift Ansprechpartner Wechselprozesse,SG4,NAD,3035,,Z13,,AnsprechpartnerWechselprozesse,X, - 159,Name und Anschrift Ansprechpartner Wechselprozesse,SG4,NAD,3036,,,,Name,X [500],[500] Hinweis: Es kann der Firmenname eines Dienstleisters oder die identische Firmenbezeichnung aus SG4 NAD+SU / DDM / DEB / Z31 / Z34 / Z35 / Z36 eingetragen werden. - 160,Name und Anschrift Ansprechpartner Wechselprozesse,SG4,NAD,3045,,Z02,,Struktur derFirmenbezeichnung,X, - 161,Name und Anschrift Ansprechpartner Wechselprozesse,SG4,NAD,3042,,,,Straße und Hausnummer oderPostfach,X, - 162,Name und Anschrift Ansprechpartner Wechselprozesse,SG4,NAD,3164,,,,Ort,X, - 163,Name und Anschrift Ansprechpartner Wechselprozesse,SG4,NAD,3251,,,,Postleitzahl,M [2]S [3],"[2] Wenn der Code im DE3207 in der ""EDI@Energy Codeliste der europäischen Ländercodes"" in der Spalte ""PLZ vorhanden"" ein ""X"" enthält - [3] wenn vorhanden" - 164,Name und Anschrift Ansprechpartner Wechselprozesse,SG4,NAD,3207,,,,"Ländername, Code",X, - 165,Ansprechpartner,SG7,,,,,,,Muss, - 166,Ansprechpartner,SG7,CTA,,,,,,Muss, - 167,Ansprechpartner,SG7,CTA,3139,,IC,,Informationskontakt,X, - 168,Ansprechpartner,SG7,CTA,3412,,,,Name der organisatorischenEinheit,X [501],"[501] Hinweis: Es darf kein Name einer natürlichen Person übermittelt werden, stattdessen ist die" - 169,Kommunikationsverbindung,SG7,COM,,,,,,Muss, - 170,Kommunikationsverbindung,SG7,COM,3148,,,,Nummer / Adresse,X (([939][6])∨ ([940][8]))∧ [502],"[6] wenn im DE3155 im demselben COM der Code EM vorhanden ist - [8] wenn im DE3155 im demselben COM der Code TE / FX vorhanden ist - [502] Hinweis: Es darf nur eine Information im DE3148 übermittelt werden - [939] Format: Die Zeichenkette muss die Zeichen @ und . enthalten - [940] Format: Die Zeichenkette muss mit dem Zeichen + beginnen und danach dürfen nur noch Ziffern folgen" - 171,Kommunikationsverbindung,SG7,COM,3155,,EM,,Elektronische Post,X [1P1..1], - 172,Kommunikationsverbindung,SG7,COM,3155,,TE,,Telefon,X [1P1..1], - 173,Kommunikationsverbindung,SG7,COM,3155,,FX,,Telefax,X [1P0..1], - 174,Name und Anschrift Ansprechpartner Stammdatenprozesse,SG4,,,,,,,Muss [10] ∧[19],"[10] Wenn BGM DE1373 = 11 (Dokument nicht verfügbar) nicht vorhanden - [19] Wenn MP-ID in SG2 NAD+MR (Nachrichtenempfänger) in der Rolle LF/MSB/ NB/ÜNB" - 175,Name und Anschrift Ansprechpartner Stammdatenprozesse,SG4,NAD,,,,,,Muss, - 176,Name und Anschrift Ansprechpartner Stammdatenprozesse,SG4,NAD,3035,,Z14,,AnsprechpartnerStammdatenprozesse,X, - 177,Name und Anschrift Ansprechpartner Stammdatenprozesse,SG4,NAD,3036,,,,Name,X [500],[500] Hinweis: Es kann der Firmenname eines Dienstleisters oder die identische Firmenbezeichnung aus SG4 NAD+SU / DDM / DEB / Z31 / Z34 / Z35 / Z36 eingetragen werden. - 178,Name und Anschrift Ansprechpartner Stammdatenprozesse,SG4,NAD,3045,,Z02,,Struktur derFirmenbezeichnung,X, - 179,Name und Anschrift Ansprechpartner Stammdatenprozesse,SG4,NAD,3042,,,,Straße und Hausnummer oderPostfach,X, - 180,Name und Anschrift Ansprechpartner Stammdatenprozesse,SG4,NAD,3164,,,,Ort,X, - 181,Name und Anschrift Ansprechpartner Stammdatenprozesse,SG4,NAD,3251,,,,Postleitzahl,M [2]S [3],"[2] Wenn der Code im DE3207 in der ""EDI@Energy Codeliste der europäischen Ländercodes"" in der Spalte ""PLZ vorhanden"" ein ""X"" enthält - [3] wenn vorhanden" - 182,Name und Anschrift Ansprechpartner Stammdatenprozesse,SG4,NAD,3207,,,,"Ländername, Code",X, - 183,Ansprechpartner,SG7,,,,,,,Muss, - 184,Ansprechpartner,SG7,CTA,,,,,,Muss, - 185,Ansprechpartner,SG7,CTA,3139,,IC,,Informationskontakt,X, - 186,Ansprechpartner,SG7,CTA,3412,,,,Name der organisatorischenEinheit,X [501],"[501] Hinweis: Es darf kein Name einer natürlichen Person übermittelt werden, stattdessen ist die organisatorische Einheit im Unternehmen zu nennen." - 187,Kommunikationsverbindung,SG7,COM,,,,,,Muss, - 188,Kommunikationsverbindung,SG7,COM,3148,,,,Nummer / Adresse,X (([939][6])∨ ([940][8]))∧ [502],"[6] wenn im DE3155 im demselben COM der Code EM vorhanden ist - [8] wenn im DE3155 im demselben COM der Code TE / FX vorhanden ist - [502] Hinweis: Es darf" - 189,Kommunikationsverbindung,SG7,COM,3155,,EM,,Elektronische Post,X [1P1..1], - 190,Kommunikationsverbindung,SG7,COM,3155,,TE,,Telefon,X [1P1..1], - 191,Kommunikationsverbindung,SG7,COM,3155,,FX,,Telefax,X [1P0..1], - 192,Name und Anschrift Ansprechpartner Einspeiseprozesse,SG4,,,,,,,Muss [10] ∧[18],"[10] Wenn BGM DE1373 = 11 (Dokument nicht verfügbar) nicht vorhanden - [17] Wenn MP-ID in SG2 NAD+MR (Nachrichtenempfänger) in der Rolle LF/NB/MSB - [18] Wenn MP-ID in SG2 NAD+MR (Nachrichtenempfänger) in der Rolle LF/MSB - [23] Wenn MP-ID in SG2 NAD+MR (Nachrichtenempfänger) in der Rolle NB/ÜNB" - 193,Name und Anschrift Ansprechpartner Einspeiseprozesse,SG4,NAD,,,,,,Muss, - 194,Name und Anschrift Ansprechpartner Einspeiseprozesse,SG4,NAD,3035,,Z16,,AnsprechpartnerEinspeiseprozesse,X, - 195,Name und Anschrift Ansprechpartner Einspeiseprozesse,SG4,NAD,3036,,,,Name,X [500],[500] Hinweis: Es kann der Firmenname eines Dienstleisters oder die identische Firmenbezeichnung aus SG4 NAD+SU / DDM / DEB / Z31 / Z34 / Z35 / Z36 eingetragen werden. - 196,Name und Anschrift Ansprechpartner Einspeiseprozesse,SG4,NAD,3045,,Z02,,Struktur derFirmenbezeichnung,X, - 197,Name und Anschrift Ansprechpartner Einspeiseprozesse,SG4,NAD,3042,,,,Straße und Hausnummer oderPostfach,X, - 198,Name und Anschrift Ansprechpartner Einspeiseprozesse,SG4,NAD,3164,,,,Ort,X, - 199,Name und Anschrift Ansprechpartner Einspeiseprozesse,SG4,NAD,3251,,,,Postleitzahl,M [2]S [3],"[2] Wenn der Code im DE3207 in der ""EDI@Energy Codeliste der europäischen Ländercodes"" in der Spalte ""PLZ vorhanden"" ein ""X"" enthält - [3] wenn vorhanden" - 200,Name und Anschrift Ansprechpartner Einspeiseprozesse,SG4,NAD,3207,,,,"Ländername, Code",X, - 201,Ansprechpartner,SG7,,,,,,,Muss, - 202,Ansprechpartner,SG7,CTA,,,,,,Muss, - 203,Ansprechpartner,SG7,CTA,3139,,IC,,Informationskontakt,X, - 204,Ansprechpartner,SG7,CTA,3412,,,,Name der organisatorischenEinheit,X [501],"[501] Hinweis: Es darf kein Name einer natürlichen Person übermittelt werden, stattdessen ist die organisatorische Einheit im Unternehmen zu nennen." - 205,Kommunikationsverbindung,SG7,COM,,,,,,Muss, - 206,Kommunikationsverbindung,SG7,COM,3148,,,,Nummer / Adresse,X (([939][6])∨ ([940][8]))∧ [502],"[6] wenn im DE3155 im demselben COM der Code EM vorhanden ist - [8] wenn im DE3155 im demselben COM der Code TE / FX vorhanden ist - [502] Hinweis: Es darf nur eine Information im DE3148 übermittelt werden - [939] Format: Die Zeichenkette muss die Zeichen @ und . enthalten " - 207,Kommunikationsverbindung,SG7,COM,3155,,EM,,Elektronische Post,X [1P1..1], - 208,Kommunikationsverbindung,SG7,COM,3155,,TE,,Telefon,X [1P1..1], - 209,Kommunikationsverbindung,SG7,COM,3155,,FX,,Telefax,X [1P0..1], - 210,Name und Anschrift Ansprechpartner Abrechnungsprozesse,SG4,,,,,,,Muss [10] ∧[18],"[10] Wenn BGM DE1373 = 11 (Dokument nicht verfügbar) nicht vorhanden - [17] Wenn MP-ID in SG2 NAD+MR (Nachrichtenempfänger) in der Rolle LF/NB/MSB - [18] Wenn MP-ID in SG2 NAD+MR (Nachrichtenempfänger) in der Rolle LF/MSB - [24] Wenn MP-ID in SG2 NAD+MR (Nachrichtenempfänger) in der Rolle NB/LF/ MSB/ESA" - 211,Name und Anschrift Ansprechpartner Abrechnungsprozesse,SG4,NAD,,,,,,Muss, - 212,Name und Anschrift Ansprechpartner Abrechnungsprozesse,SG4,NAD,3035,,Z17,,AnsprechpartnerAbrechnungsprozesse,X, - 213,Name und Anschrift Ansprechpartner Abrechnungsprozesse,SG4,NAD,3036,,,,Name,X [500],[500] Hinweis: Es kann der Firmenname eines Dienstleisters oder die identische Firmenbezeichnung aus SG4 NAD+SU / DDM / DEB / Z31 / Z34 / Z35 / Z36 eingetragen werden. - 214,Name und Anschrift Ansprechpartner Abrechnungsprozesse,SG4,NAD,3045,,Z02,,Struktur derFirmenbezeichnung,X, - 215,Name und Anschrift Ansprechpartner Abrechnungsprozesse,SG4,NAD,3042,,,,Straße und Hausnummer oderPostfach,X, - 216,Name und Anschrift Ansprechpartner Abrechnungsprozesse,SG4,NAD,3164,,,,Ort,X, - 217,Name und Anschrift Ansprechpartner Abrechnungsprozesse,SG4,NAD,3251,,,,Postleitzahl,M [2]S [3],[2] Wenn der Code im DE3207 in der - 218,Name und Anschrift Ansprechpartner Abrechnungsprozesse,SG4,NAD,3207,,,,"Ländername, Code",X, - 219,Ansprechpartner,SG7,,,,,,,Muss, - 220,Ansprechpartner,SG7,CTA,,,,,,Muss, - 221,Ansprechpartner,SG7,CTA,3139,,IC,,Informationskontakt,X, - 222,Ansprechpartner,SG7,CTA,3412,,,,Name der organisatorischenEinheit,X [501],"[501] Hinweis: Es darf kein Name einer natürlichen Person übermittelt werden, stattdessen ist die organisatorische Einheit im Unternehmen zu nennen." - 223,Kommunikationsverbindung,SG7,COM,,,,,,Muss, - 224,Kommunikationsverbindung,SG7,COM,3148,,,,Nummer / Adresse,X (([939][6])∨ ([940][8]))∧ [502],"[6] wenn im DE3155 im demselben COM der Code EM vorhanden ist - [8] wenn im DE3155 im demselben COM der Code TE / FX vorhanden ist - [502] Hinweis: Es darf nur eine Information im DE3148 übermittelt werden - [939] Format: Die Zeichenkette muss die Zeichen @ und . enthalten - [940] Format: Die Zeichenkette muss mit dem Zeichen + beginnen und danach dürfen nur noch Ziffern folgen" - 225,Kommunikationsverbindung,SG7,COM,3155,,EM,,Elektronische Post,X [1P1..1], - 226,Kommunikationsverbindung,SG7,COM,3155,,TE,,Telefon,X [1P1..1], - 227,Name und Anschrift Ansprechpartner MMMA- Prozesse,SG4,,,,,,,Muss [10] ∧[20],"[10] Wenn BGM DE1373 = 11 (Dokument nicht verfügbar) nicht vorhanden - [17] Wenn MP-ID in SG2 NAD+MR (Nachrichtenempfänger) in der Rolle LF/NB/MSB - [20] Wenn MP-ID in SG2 NAD+MR (Nachrichtenempfänger) in der Rolle LF/MSB/ÜNB" - 228,Name und Anschrift Ansprechpartner MMMA- Prozesse,SG4,NAD,,,,,,Muss, - 229,Name und Anschrift Ansprechpartner MMMA- Prozesse,SG4,NAD,3035,,Z18,,AnsprechpartnerMMMA-Prozesse,X, - 230,Name und Anschrift Ansprechpartner MMMA- Prozesse,SG4,NAD,3036,,,,Name,X [500],[500] Hinweis: Es kann der Firmenname eines Dienstleisters oder die identische Firmenbezeichnung aus SG4 NAD+SU / DDM / DEB / Z31 / Z34 / Z35 / Z36 eingetragen werden. - 231,Name und Anschrift Ansprechpartner MMMA- Prozesse,SG4,NAD,3045,,Z02,,Struktur derFirmenbezeichnung,X, - 232,Name und Anschrift Ansprechpartner MMMA- Prozesse,SG4,NAD,3042,,,,Straße und Hausnummer oderPostfach,X, - 233,Name und Anschrift Ansprechpartner MMMA- Prozesse,SG4,NAD,3164,,,,Ort,X, - 234,Name und Anschrift Ansprechpartner MMMA- Prozesse,SG4,NAD,3251,,,,Postleitzahl,M [2]S [3],"[2] Wenn der Code im DE3207 in der ""EDI@Energy Codeliste der europäischen Ländercodes"" in der Spalte ""PLZ vorhanden"" ein ""X"" enthält - [3] wenn vorhanden" - 235,Name und Anschrift Ansprechpartner MMMA- Prozesse,SG4,NAD,3207,,,,"Ländername, Code",X, - 236,Ansprechpartner,SG7,,,,,,,Muss, - 237,Ansprechpartner,SG7,CTA,,,,,,Muss, - 238,Ansprechpartner,SG7,CTA,3139,,IC,,Informationskontakt,X, - 239,Ansprechpartner,SG7,CTA,3412,,,,Name der organisatorischenEinheit,X [501],"[501] Hinweis: Es darf kein Name einer natürlichen Person übermittelt werden, stattdessen ist die organisatorische Einheit im Unternehmen zu nennen." - 240,Kommunikationsverbindung,SG7,COM,,,,,,Muss, - 241,Kommunikationsverbindung,SG7,COM,3148,,,,Nummer / Adresse,X (([939][6])∨ ([940][8]))∧ [502],"[6] wenn im DE3155 im demselben COM der Code EM vorhanden ist - [8] wenn im DE3155 im demselben COM der Code TE / FX vorhanden ist - [502] Hinweis: Es darf nur eine Information im DE3148 übermittelt werden - [939] Format: Die Zeichenkette muss die Zeichen @ und . enthalten - [940] Format: Die Zeichenkette muss mit dem Zeichen + beginnen und danach dürfen nur noch Ziffern folgen" - 242,Kommunikationsverbindung,SG7,COM,3155,,EM,,Elektronische Post,X [1P1..1], - 243,Kommunikationsverbindung,SG7,COM,3155,,TE,,Telefon,X [1P1..1], - 244,Kommunikationsverbindung,SG7,COM,3155,,FX,,Telefax,X [1P0..1], - 245,Name und Anschrift Bewegungsdaten,SG4,,,,,,,Muss [10] ∧[19],"[10] Wenn BGM DE1373 = 11 (Dokument nicht verfügbar) nicht vorhanden - [19] Wenn MP-ID in SG2 NAD+MR (Nachrichtenempfänger) in der Rolle LF/MSB/" - 246,Name und Anschrift Bewegungsdaten,SG4,NAD,,,,,,Muss, - 247,Name und Anschrift Bewegungsdaten,SG4,NAD,3035,,Z19,,AnsprechpartnerBewegungsdaten,X, - 248,Name und Anschrift Bewegungsdaten,SG4,NAD,3036,,,,Name,X [500],[500] Hinweis: Es kann der Firmenname eines Dienstleisters oder die identische Firmenbezeichnung aus SG4 NAD+SU / DDM / DEB / Z31 / Z34 / Z35 / Z36 eingetragen werden. - 249,Name und Anschrift Bewegungsdaten,SG4,NAD,3045,,Z02,,Struktur derFirmenbezeichnung,X, - 250,Name und Anschrift Bewegungsdaten,SG4,NAD,3042,,,,Straße und Hausnummer oderPostfach,X, - 251,Name und Anschrift Bewegungsdaten,SG4,NAD,3164,,,,Ort,X, - 252,Name und Anschrift Bewegungsdaten,SG4,NAD,3251,,,,Postleitzahl,M [2]S [3],"[2] Wenn der Code im DE3207 in der ""EDI@Energy Codeliste der europäischen Ländercodes"" in der Spalte ""PLZ vorhanden"" ein ""X"" enthält - [3] wenn vorhanden" - 253,Name und Anschrift Bewegungsdaten,SG4,NAD,3207,,,,"Ländername, Code",X, - 254,Ansprechpartner,SG7,,,,,,,Muss, - 255,Ansprechpartner,SG7,CTA,,,,,,Muss, - 256,Ansprechpartner,SG7,CTA,3139,,IC,,Informationskontakt,X, - 257,Ansprechpartner,SG7,CTA,3412,,,,Name der organisatorischenEinheit,X [501],"[501] Hinweis: Es darf kein Name einer natürlichen Person übermittelt werden, stattdessen ist die organisatorische Einheit im Unternehmen zu nennen." - 258,Kommunikationsverbindung,SG7,COM,,,,,,Muss, - 259,Kommunikationsverbindung,SG7,COM,3148,,,,Nummer / Adresse,X (([939][6])∨ ([940][8]))∧ [502],"[6] wenn im DE3155 im demselben COM der Code EM vorhanden ist - [8] wenn im DE3155 im demselben COM der" - 260,Kommunikationsverbindung,SG7,COM,3155,,EM,,Elektronische Post,X [1P1..1], - 261,Kommunikationsverbindung,SG7,COM,3155,,TE,,Telefon,X [1P1..1], - 262,Kommunikationsverbindung,SG7,COM,3155,,FX,,Telefax,X [1P0..1], - 263,Name und Anschrift Ansprechpartner Prozesse zur Unterbrechung und Wiederherstellung der Anschlussnutzung,SG4,,,,,,,Muss [10] ∧[20],"[10] Wenn BGM DE1373 = 11 (Dokument nicht verfügbar) nicht vorhanden - [17] Wenn MP-ID in SG2 NAD+MR (Nachrichtenempfänger) in der Rolle LF/NB/MSB - [20] Wenn MP-ID in SG2 NAD+MR (Nachrichtenempfänger) in der Rolle LF/MSB/ÜNB" - 264,Name und Anschrift Ansprechpartner Prozesse zur Unterbrechung und Wiederherstellung der Anschlussnutzung,SG4,NAD,,,,,,Muss, - 265,Name und Anschrift Ansprechpartner Prozesse zur Unterbrechung und Wiederherstellung der Anschlussnutzung,SG4,NAD,3035,,Z20,,AnsprechpartnerSperr-/Entsperrprozesse,X, - 266,Name und Anschrift Ansprechpartner Prozesse zur Unterbrechung und Wiederherstellung der Anschlussnutzung,SG4,NAD,3036,,,,Name,X [500],[500] Hinweis: Es kann der Firmenname eines Dienstleisters oder die identische Firmenbezeichnung aus SG4 NAD+SU / DDM / DEB / Z31 / Z34 / Z35 / - 267,Name und Anschrift Ansprechpartner Prozesse zur Unterbrechung und Wiederherstellung der Anschlussnutzung,SG4,NAD,3045,,Z02,,Struktur derFirmenbezeichnung,X, - 268,Name und Anschrift Ansprechpartner Prozesse zur Unterbrechung und Wiederherstellung der Anschlussnutzung,SG4,NAD,3042,,,,Straße und Hausnummer oderPostfach,X, - 269,Name und Anschrift Ansprechpartner Prozesse zur Unterbrechung und Wiederherstellung der Anschlussnutzung,SG4,NAD,3164,,,,Ort,X, - 270,Name und Anschrift Ansprechpartner Prozesse zur Unterbrechung und Wiederherstellung der Anschlussnutzung,SG4,NAD,3251,,,,Postleitzahl,M [2]S [3],"[2] Wenn der Code im DE3207 in der ""EDI@Energy Codeliste der europäischen Ländercodes"" in der Spalte ""PLZ vorhanden"" ein ""X"" enthält - [3] wenn vorhanden" - 271,Name und Anschrift Ansprechpartner Prozesse zur Unterbrechung und Wiederherstellung der Anschlussnutzung,SG4,NAD,3207,,,,"Ländername, Code",X, - 272,Ansprechpartner,SG7,,,,,,,Muss, - 273,Ansprechpartner,SG7,CTA,,,,,,Muss, - 274,Ansprechpartner,SG7,CTA,3139,,IC,,Informationskontakt,X, - 275,Ansprechpartner,SG7,CTA,3412,,,,Name der organisatorischenEinheit,X [501],"[501] Hinweis: Es darf kein Name einer natürlichen Person übermittelt werden, stattdessen ist die organisatorische Einheit im Unternehmen zu nennen." - 276,Kommunikationsverbindung,SG7,COM,,,,,,Muss, - 277,Kommunikationsverbindung,SG7,COM,3148,,,,Nummer / Adresse,X (([939][6])∨ ([940][8]))∧ [502],"[6] wenn im DE3155 im demselben COM der Code EM vorhanden ist - [8] wenn im DE3155 im demselben COM der Code TE / FX vorhanden ist - [502] Hinweis: Es darf nur eine Information im DE3148 übermittelt werden - [939] Format: Die Zeichenkette muss die Zeichen @ und ." - 278,Kommunikationsverbindung,SG7,COM,3155,,EM,,Elektronische Post,X [1P1..1], - 279,Kommunikationsverbindung,SG7,COM,3155,,TE,,Telefon,X [1P1..1], - 280,Kommunikationsverbindung,SG7,COM,3155,,FX,,Telefax,X [1P0..1], - 281,Name und Anschrift Ansprechpartner Bilanzierungsprozesse / Bilanzkreismanagement,SG4,,,,,,,Muss [10],[10] Wenn BGM DE1373 = 11 (Dokument nicht verfügbar) nicht vorhanden - 282,Name und Anschrift Ansprechpartner Bilanzierungsprozesse / Bilanzkreismanagement,SG4,NAD,,,,,,Muss, - 283,Name und Anschrift Ansprechpartner Bilanzierungsprozesse / Bilanzkreismanagement,SG4,NAD,3035,,Z21,,AnsprechpartnerBilanzierungsprozesse /Bilanzkreismanagement,X, - 284,Name und Anschrift Ansprechpartner Bilanzierungsprozesse / Bilanzkreismanagement,SG4,NAD,3036,,,,Name,X [500],[500] Hinweis: Es kann der Firmenname eines Dienstleisters oder die identische Firmenbezeichnung aus SG4 NAD+SU / DDM / DEB / Z31 / Z34 / Z35 / Z36 eingetragen werden. - 285,Name und Anschrift Ansprechpartner Bilanzierungsprozesse / Bilanzkreismanagement,SG4,NAD,3045,,Z02,,Struktur derFirmenbezeichnung,X, - 286,Name und Anschrift Ansprechpartner Bilanzierungsprozesse / Bilanzkreismanagement,SG4,NAD,3042,,,,Straße und Hausnummer oderPostfach,X, - 287,Name und Anschrift Ansprechpartner Bilanzierungsprozesse / Bilanzkreismanagement,SG4,NAD,3164,,,,Ort,X, - 288,Name und Anschrift Ansprechpartner Bilanzierungsprozesse / Bilanzkreismanagement,SG4,NAD,3251,,,,Postleitzahl,M [2]S [3],"[2] Wenn der Code im DE3207 in der ""EDI@Energy Codeliste der europäischen Ländercodes"" in der Spalte ""PLZ vorhanden"" ein ""X"" enthält - [3] wenn vorhanden" - 289,Name und Anschrift Ansprechpartner Bilanzierungsprozesse / Bilanzkreismanagement,SG4,NAD,3207,,,,"Ländername, Code",X, - 290,Ansprechpartner,SG7,,,,,,,Muss, - 291,Ansprechpartner,SG7,CTA,,,,,,Muss, - 292,Ansprechpartner,SG7,CTA,3139,,IC,,Informationskontakt,X, - 293,Ansprechpartner,SG7,CTA,3412,,,,Name der organisatorischenEinheit,X [501],"[501] Hinweis: Es darf kein Name einer natürlichen Person übermittelt werden, stattdessen ist die organisatorische Einheit im Unternehmen zu nennen." - 294,Kommunikationsverbindung,SG7,COM,,,,,,Muss, - 295,Kommunikationsverbindung,SG7,COM,3148,,,,Nummer / Adresse,X (([939][6])∨ ([940][8]))∧ [502],"[6] wenn im DE3155 im demselben COM der Code EM vorhanden ist - [8] wenn im DE3155 im demselben COM der Code TE / FX vorhanden ist - [502] Hinweis: Es darf nur eine Information im DE3148 übermittelt werden - [939] Format: Die Zeichenkette muss die Zeichen @ und . enthalten - [940] Format: Die Zeichenkette muss mit dem Zeichen + beginnen und danach dürfen nur noch Ziffern folgen" - 296,Kommunikationsverbindung,SG7,COM,3155,,EM,,Elektronische Post,X [1P1..1], - 297,Kommunikationsverbindung,SG7,COM,3155,,TE,,Telefon,X [1P1..1], - 298,Kommunikationsverbindung,SG7,COM,3155,,FX,,Telefax,X [1P0..1], - 299,Name und Anschrift Ansprechpartner Technischer Netzanschluss für Neuanlagen und Anlagenumbau,SG4,,,,,,,Muss [10] ∧ [18],[10] Wenn BGM DE1373 = 11 (Dokument nicht verfügbar) nicht vorhanden - 300,Name und Anschrift Ansprechpartner Technischer Netzanschluss für Neuanlagen und Anlagenumbau,SG4,NAD,,,,,,Muss, - 301,Name und Anschrift Ansprechpartner Technischer Netzanschluss für Neuanlagen und Anlagenumbau,SG4,NAD,3035,,Z33,,AnsprechpartnertechnischerNetzanschluss fürNeuanlagen undAnlagenumbau,X, - 302,Name und Anschrift Ansprechpartner Technischer Netzanschluss für Neuanlagen und Anlagenumbau,SG4,NAD,3036,,,,Name,X [500],[500] Hinweis: Es kann der Firmenname eines Dienstleisters oder die identische Firmenbezeichnung aus SG4 NAD+SU / DDM / DEB / Z31 / Z34 / Z35 / Z36 eingetragen werden. - 303,Name und Anschrift Ansprechpartner Technischer Netzanschluss für Neuanlagen und Anlagenumbau,SG4,NAD,3045,,Z02,,Struktur derFirmenbezeichnung,X, - 304,Name und Anschrift Ansprechpartner Technischer Netzanschluss für Neuanlagen und Anlagenumbau,SG4,NAD,3042,,,,Straße und Hausnummer oderPostfach,X, - 305,Name und Anschrift Ansprechpartner Technischer Netzanschluss für Neuanlagen und Anlagenumbau,SG4,NAD,3164,,,,Ort,X, - 306,Name und Anschrift Ansprechpartner Technischer Netzanschluss für Neuanlagen und Anlagenumbau,SG4,NAD,3251,,,,Postleitzahl,M [2]S [3],"[2] Wenn der Code im DE3207 in der ""EDI@Energy Codeliste der europäischen Ländercodes"" in der Spalte ""PLZ vorhanden"" ein ""X"" enthält - [3] wenn vorhanden" - 307,Name und Anschrift Ansprechpartner Technischer Netzanschluss für Neuanlagen und Anlagenumbau,SG4,NAD,3207,,,,"Ländername, Code",X, - 308,Ansprechpartner,SG7,,,,,,,Muss, - 309,Ansprechpartner,SG7,CTA,,,,,,Muss, - 310,Ansprechpartner,SG7,CTA,3139,,IC,,Informationskontakt,X, - 311,Ansprechpartner,SG7,CTA,3412,,,,Name der organisatorischenEinheit,X [501],"[501] Hinweis: Es darf kein Name einer natürlichen Person übermittelt werden, stattdessen ist die organisatorische Einheit im Unternehmen zu nennen." - 312,Kommunikationsverbindung,SG7,COM,,,,,,Muss, - 313,Kommunikationsverbindung,SG7,COM,3148,,,,Nummer / Adresse,X (([939][6])∨ ([940][8]))∧ [502],"[6] wenn im DE3155 im demselben COM der Code EM vorhanden ist - [8] wenn im DE3155 im demselben COM der Code TE / FX vorhanden ist - [502] Hinweis: Es darf nur eine Information im DE3148 übermittelt werden - [939] Format: Die Zeichenkette muss die Zeichen @ und . enthalten - [940] Format: Die Zeichenkette muss mit dem Zeichen + beginnen und danach dürfen nur noch Ziffern folgen" - 314,Kommunikationsverbindung,SG7,COM,3155,,EM,,Elektronische Post,X [1P1..1], - 315,Kommunikationsverbindung,SG7,COM,3155,,TE,,Telefon,X [1P1..1], - 316,Kommunikationsverbindung,SG7,COM,3155,,FX,,Telefax,X [1P0..1], - 317,Nachrichten-Endesegment,,UNT,,,,,,Muss, - 318,Nachrichten-Endesegment,,UNT,0074,,,,Anzahl der Segmente in einerNachricht,X, - 319,Nachrichten-Endesegment,,UNT,0062,,,,Nachrichten-Referenznummer,X, - - ''', - '37002.csv': ''' - ,Segmentname,Segmentgruppe,Segment,Datenelement,Segment ID,Code,Qualifier,Beschreibung,Bedingungsausdruck,Bedingung - 0,Nachrichten-Kopfsegment,,UNH,,,,,,Muss, - 1,Nachrichten-Kopfsegment,,UNH,0062,,,,Nachrichten-Referenznummer,X, - 2,Nachrichten-Kopfsegment,,UNH,0065,,PARTIN,,Partnerstammdaten,X, - 3,Nachrichten-Kopfsegment,,UNH,0052,,D,,Entwurfs-Version,X, - 4,Nachrichten-Kopfsegment,,UNH,0054,,20B,,Ausgabe 2020 - B,X, - 5,Nachrichten-Kopfsegment,,UNH,0051,,UN,,UN/CEFACT,X, - 6,Nachrichten-Kopfsegment,,UNH,0057,,1.0c,,Versionsnummer derzugrundeliegendenBDEW-Nachrichtenbeschreibung,X, - 7,Beginn der Nachricht,,BGM,,,,,,Muss, - 8,Beginn der Nachricht,,BGM,1001,,10,,Partnerstammdaten,X, - 9,Beginn der Nachricht,,BGM,1004,,,,Dokumentennummer,X, - 10,Beginn der Nachricht,,BGM,1373,,11,,Dokument nichtverfügbar,S [9],[9] Wenn die Kommunikationsdaten vom Absender nicht mehr aktiv sind. - 11,Nachrichtendatum,,DTM,,,,,,Muss, - 12,Nachrichtendatum,,DTM,2005,,137,,Dokumenten-/Nachrichtendatum/-zeit,X, - 13,Nachrichtendatum,,DTM,2380,,,,"Datum oder Uhrzeit oderZeitspanne, Wert",X [931][494],"[494] Das hier genannte Datum muss der Zeitpunkt sein, zu dem das Dokument erstellt wurde, oder ein Zeitpunkt, der davor liegt. - [931] Format: ZZZ = +00" - 14,Nachrichtendatum,,DTM,2379,,303,,CCYYMMDDHHMMZZZ,X, - 15,Prüfidentifikator,SG1,,,,,,,Muss, - 16,Prüfidentifikator,SG1,RFF,,,,,,Muss, - 17,Prüfidentifikator,SG1,RFF,1153,,Z13,,Prüfidentifikator,X, - 18,Prüfidentifikator,SG1,RFF,1154,,37000,,ÜbermittlungKommunikationsdatendes LF,, - 19,Prüfidentifikator,SG1,RFF,1154,,37001,,ÜbermittlungKommunikationsdatendes NB,, - 20,Prüfidentifikator,SG1,RFF,1154,,37002,,ÜbermittlungKommunikationsdatendes MSB,X, - 21,Versionsnummer,SG1,,,,,,,Muss, - 22,Versionsnummer,SG1,RFF,,,,,,Muss, - 23,Versionsnummer,SG1,RFF,1153,,AGK,,Anwendungsreferenznummer,X, - 24,Versionsnummer,SG1,RFF,1056,,,,Versionsnummer,X [908][505],"[505] Wenn eine Vorgängerversion (RFF+ACW) angegeben ist, so muss der Wert in diesem DE1056 mindestens um 1 höher sein, als der Wert aus DE1056 der Vorgängerversion (RFF+ACW). - [908] Format: Mögliche Werte: 1 bis n" - 25,Gültig Ab,SG1,DTM,,,,,,Soll [4],[4] Wenn Vorgängerversion vorhanden - 26,Gültig Ab,SG1,DTM,2005,,157,,"Gültigkeit, Beginndatum",X, - 27,Gültig Ab,SG1,DTM,2380,,,,"Datum oder Uhrzeit oderZeitspanne, Wert",X [UB1], - 28,Gültig Ab,SG1,DTM,2379,,303,,CCYYMMDDHHMMZZZ,X, - 29,Vorgängerversion,SG1,,,,,,,Soll [4],[4] Wenn Vorgängerversion vorhanden - 30,Vorgängerversion,SG1,RFF,,,,,,Muss, - 31,Vorgängerversion,SG1,RFF,1153,,ACW,,Referenznummer einervorangegangenenNachricht,X, - 32,Vorgängerversion,SG1,RFF,1056,,,,Versionsnummer,X [908],[908] Format: Mögliche Werte: 1 bis n - 33,MP-ID Absender,SG2,,,,,,,Muss, - 34,MP-ID Absender,SG2,NAD,,,,,,Muss, - 35,MP-ID Absender,SG2,NAD,3035,,MS,,Dokumenten-/Nachrichtenausstellerbzw. -absender,X, - 36,MP-ID Absender,SG2,NAD,3039,,,,MP-ID,X [1],[1] Nur MP-ID aus Sparte Strom - 37,MP-ID Absender,SG2,NAD,3055,,9,,GS1,X, - 38,MP-ID Absender,SG2,NAD,3055,,293,,"DE, BDEW",X, - 39,Ansprechpartner,SG3,,,,,,,Kann, - 40,Ansprechpartner,SG3,CTA,,,,,,Muss, - 41,Ansprechpartner,SG3,CTA,3139,,IC,,Informationskontakt,X, - 42,Ansprechpartner,SG3,CTA,3412,,,,Name vom Ansprechpartner,X, - 43,Kommunikationsverbindung,SG3,COM,,,,,,Muss, - 44,Kommunikationsverbindung,SG3,COM,3148,,,,Nummer / Adresse,X (([939][6])∨ ([940][7]))∧ [502],"[6] wenn im DE3155 im demselben COM der Code EM vorhanden ist - [7] wenn im DE3155 im demselben COM der Code TE / FX / AJ / AL vorhanden ist - [502] Hinweis: Es darf nur eine Information im DE3148 übermittelt werden - [939] Format: Die Zeichenkette muss die Zeichen @ und . enthalten - [940] Format: Die Zeichenkette muss mit dem Zeichen + beginnen und danach dürfen nur noch Ziffern folgen" - 45,Kommunikationsverbindung,SG3,COM,3155,,EM,,Elektronische Post,X [1P0..1], - 46,Kommunikationsverbindung,SG3,COM,3155,,FX,,Telefax,X [1P0..1], - 47,Kommunikationsverbindung,SG3,COM,3155,,TE,,Telefon,X [1P0..1], - 48,Kommunikationsverbindung,SG3,COM,3155,,AJ,,weiteres Telefon,X [1P0..1], - 49,Kommunikationsverbindung,SG3,COM,3155,,AL,,Handy,X [1P0..1], - 50,MP-ID Empfänger,SG2,,,,,,,Muss, - 51,MP-ID Empfänger,SG2,NAD,,,,,,Muss, - 52,MP-ID Empfänger,SG2,NAD,3035,,MR,,Nachrichtenempfänger,X, - 53,MP-ID Empfänger,SG2,NAD,3039,,,,MP-ID,X [1],[1] Nur MP-ID aus Sparte Strom - 54,MP-ID Empfänger,SG2,NAD,3055,,9,,GS1,X, - 55,MP-ID Empfänger,SG2,NAD,3055,,293,,"DE, BDEW",X, - 56,Abschnitts-Kontrollsegment,,UNS,,,,,,Muss, - 57,Abschnitts-Kontrollsegment,,UNS,0081,,D,,Trennung von Kopf- undPositionsteil,X, - 58,Name und Adresse des Unternehmens,SG4,,,,,,,Muss [10],[10] Wenn BGM DE1373 = 11 (Dokument nicht verfügbar) nicht vorhanden - 59,Name und Adresse des Unternehmens,SG4,NAD,,,,,,Muss, - 60,Name und Adresse des Unternehmens,SG4,NAD,3035,,SU,,Lieferant,, - 61,Name und Adresse des Unternehmens,SG4,NAD,3035,,DDM,,Netzbetreiber,, - 62,Name und Adresse des Unternehmens,SG4,NAD,3035,,DEB,,Messstellenbetreiber,X, - 63,Name und Adresse des Unternehmens,SG4,NAD,3036,,,,Name,X [506],"[506] Hinweis: Das Datenelement ist so zu füllen, dass sein Inhalt den Vorgaben des USt.- Gesetzes genügt, so dass der Empfänger diese Daten in einer INVOIC nutzen kann." - 64,Name und Adresse des Unternehmens,SG4,NAD,3045,,Z02,,Struktur derFirmenbezeichnung,X, - 65,Name und Adresse des Unternehmens,SG4,NAD,3042,,,,Straße und Hausnummer oderPostfach,X [506],"[506] Hinweis: Das Datenelement ist so zu füllen, dass sein Inhalt den Vorgaben des USt.- Gesetzes genügt, so dass der Empfänger diese Daten in einer INVOIC nutzen kann." - 66,Name und Adresse des Unternehmens,SG4,NAD,3164,,,,Ort,X [506],"[506] Hinweis: Das Datenelement ist so zu füllen, dass sein Inhalt den Vorgaben des USt.- Gesetzes genügt, so dass der Empfänger diese Daten in einer INVOIC nutzen kann." - 67,Name und Adresse des Unternehmens,SG4,NAD,3251,,,,Postleitzahl,M [2] ∧[506]S [3] ∧ [506],"[2] Wenn der Code im DE3207 in der ""EDI@Energy Codeliste der europäischen Ländercodes"" in der Spalte ""PLZ vorhanden""" - 68,Name und Adresse des Unternehmens,SG4,NAD,3207,,,,"Ländername, Code",X [506],"[506] Hinweis: Das Datenelement ist so zu füllen, dass sein Inhalt den Vorgaben des USt.- Gesetzes genügt, so dass der Empfänger diese Daten in einer INVOIC nutzen kann." - 69,Bankverbindung,SG4,FII,,,,,,Muss, - 70,Bankverbindung,SG4,FII,3035,,BK,,Kreditinstitut,X, - 71,Bankverbindung,SG4,FII,3194,,IBAN,,,X, - 72,Bankverbindung,SG4,FII,3192,,,,Name des Kontoinhabers,X, - 73,Bankverbindung,SG4,FII,3192,,,,Name des Kontoinhabers,K, - 74,Bankverbindung,SG4,FII,3433,,BIC,,,X, - 75,Bankverbindung,SG4,FII,3432,,,,Name des Kredinstituts,X, - 76,Internetseite (URL),SG4,FTX,,,,,,Muss, - 77,Internetseite (URL),SG4,FTX,4451,,Z13,,Internetseite,X, - 78,Internetseite (URL),SG4,FTX,4440,,,,Internetseite,X, - 79,Gericht und Handelsregister-Nummer,SG4,FTX,,,,,,Soll [3],[3] wenn vorhanden - 80,Gericht und Handelsregister-Nummer,SG4,FTX,4451,,Z15,,Gericht undHandelsregister-Nummer,X, - 81,Gericht und Handelsregister-Nummer,SG4,FTX,4440,,,,Gericht,X, - 82,Gericht und Handelsregister-Nummer,SG4,FTX,4440,,,,Handelsregister-Nummer,X, - 83,"Steuernummer, Umsatzsteuernummer",SG6,,,,,,,Muss [504],[504] Hinweis: Es ist mindestens die - 84,"Steuernummer, Umsatzsteuernummer",SG6,RFF,,,,,,Muss, - 85,"Steuernummer, Umsatzsteuernummer",SG6,RFF,1153,,VA,,Umsatzsteuernummer,X [2P0..1] ⊻[3P1..1], - 86,"Steuernummer, Umsatzsteuernummer",SG6,RFF,1153,,FC,,Steuernummer,X [2P0..1], - 87,"Steuernummer, Umsatzsteuernummer",SG6,RFF,1154,,,,"Referenz, Identifikation",X, - 88,Faxnummer,SG6,RFF,,,,,,Kann, - 89,Faxnummer,SG6,RFF,1153,,Z25,,Faxnummer,X, - 90,Faxnummer,SG6,RFF,1154,,,,Faxnummer,X [940],[940] Format: Die Zeichenkette muss mit dem Zeichen + beginnen und danach dürfen nur noch Ziffern folgen - 91,Erreichbarkeit an Werktagen,SG12,,,,,,,Muss, - 92,Erreichbarkeit an Werktagen,SG12,CCI,,,,,,Muss, - 93,Erreichbarkeit an Werktagen,SG12,CCI,7059,,Z40,,Erreichbarkeit desUnternehmens,X, - 94,Erreichbarkeit,SG12,DTM,,,,,,Muss, - 95,Erreichbarkeit,SG12,DTM,2005,,Z36,,Verfügbarkeit Montag,X [1P1..1], - 96,Erreichbarkeit,SG12,DTM,2005,,Z37,,Verfügbarkeit Dienstag,X [1P1..1], - 97,Erreichbarkeit,SG12,DTM,2005,,Z38,,Verfügbarkeit Mittwoch,X [1P1..1], - 98,Erreichbarkeit,SG12,DTM,2005,,Z39,,VerfügbarkeitDonnerstag,X [1P1..1], - 99,Erreichbarkeit,SG12,DTM,2005,,Z40,,Verfügbarkeit Freitag,X [1P1..1], - 100,Erreichbarkeit,SG12,DTM,2005,,Z41,,Mittagspause (=Ausschluss derVerfügbarkeit),X [1P0..1], - 101,Erreichbarkeit,SG12,DTM,2380,,,,"Datum oder Uhrzeit oderZeitspanne, Wert",X [503],[503] Hinweis: Angabe erfolgt in gesetzlicher deutscher Zeit - 102,Erreichbarkeit,SG12,DTM,2379,,501,,HHMMHHMM,X, - 103,Name und Anschrift Ansprechpartner Übertragungsweg / Datenaustausch,SG4,,,,,,,Muss [10],[10] Wenn BGM DE1373 = 11 (Dokument nicht verfügbar) nicht - 104,Name und Anschrift Ansprechpartner Übertragungsweg / Datenaustausch,SG4,NAD,,,,,,Muss, - 105,Name und Anschrift Ansprechpartner Übertragungsweg / Datenaustausch,SG4,NAD,3035,,Z10,,AnsprechpartnerÜbertragungsweg /Datenaustausch,X, - 106,Name und Anschrift Ansprechpartner Übertragungsweg / Datenaustausch,SG4,NAD,3036,,,,Name,X [500],[500] Hinweis: Es kann der Firmenname eines Dienstleisters oder die identische Firmenbezeichnung aus SG4 NAD+SU / DDM / DEB / Z31 / Z34 / Z35 / Z36 eingetragen werden. - 107,Name und Anschrift Ansprechpartner Übertragungsweg / Datenaustausch,SG4,NAD,3045,,Z02,,Struktur derFirmenbezeichnung,X, - 108,Name und Anschrift Ansprechpartner Übertragungsweg / Datenaustausch,SG4,NAD,3042,,,,Straße und Hausnummer oderPostfach,X, - 109,Name und Anschrift Ansprechpartner Übertragungsweg / Datenaustausch,SG4,NAD,3164,,,,Ort,X, - 110,Name und Anschrift Ansprechpartner Übertragungsweg / Datenaustausch,SG4,NAD,3251,,,,Postleitzahl,M [2]S [3],"[2] Wenn der Code im DE3207 in der ""EDI@Energy Codeliste der europäischen Ländercodes"" in der Spalte ""PLZ vorhanden"" ein ""X"" enthält - [3] wenn vorhanden" - 111,Name und Anschrift Ansprechpartner Übertragungsweg / Datenaustausch,SG4,NAD,3207,,,,"Ländername, Code",X, - 112,Ansprechpartner,SG7,,,,,,,Muss, - 113,Ansprechpartner,SG7,CTA,,,,,,Muss, - 114,Ansprechpartner,SG7,CTA,3139,,IC,,Informationskontakt,X, - 115,Ansprechpartner,SG7,CTA,3412,,,,Name der organisatorischenEinheit,X [501],"[501] Hinweis: Es darf kein Name einer natürlichen Person übermittelt werden, stattdessen ist die organisatorische Einheit im Unternehmen zu nennen." - 116,Kommunikationsverbindung,SG7,COM,,,,,,Muss, - 117,Kommunikationsverbindung,SG7,COM,3148,,,,Nummer / Adresse,X (([939][6])∨ ([940][8]))∧ [502],"[6] wenn im DE3155 im demselben COM der Code EM vorhanden ist - [8] wenn im DE3155 im" - 118,Kommunikationsverbindung,SG7,COM,3155,,EM,,Elektronische Post,X [1P1..1], - 119,Kommunikationsverbindung,SG7,COM,3155,,TE,,Telefon,X [1P1..1], - 120,Kommunikationsverbindung,SG7,COM,3155,,FX,,Telefax,X [1P0..1], - 121,Name und Anschrift Ansprechpartner Rahmenverträge,SG4,,,,,,,Muss [10] ∧[21],"[10] Wenn BGM DE1373 = 11 (Dokument nicht verfügbar) nicht vorhanden - [17] Wenn MP-ID in SG2 NAD+MR (Nachrichtenempfänger) in der Rolle LF/NB/MSB - [18] Wenn MP-ID in SG2 NAD+MR (Nachrichtenempfänger) in der Rolle LF/MSB - [21] Wenn MP-ID in SG2 NAD+MR (Nachrichtenempfänger) in der Rolle LF/NB/ESA" - 122,Name und Anschrift Ansprechpartner Rahmenverträge,SG4,NAD,,,,,,Muss, - 123,Name und Anschrift Ansprechpartner Rahmenverträge,SG4,NAD,3035,,Z11,,AnsprechpartnerRahmenverträge,X, - 124,Name und Anschrift Ansprechpartner Rahmenverträge,SG4,NAD,3036,,,,Name,X [500],[500] Hinweis: Es kann der Firmenname eines Dienstleisters oder die - 125,Name und Anschrift Ansprechpartner Rahmenverträge,SG4,NAD,3045,,Z02,,Struktur derFirmenbezeichnung,X, - 126,Name und Anschrift Ansprechpartner Rahmenverträge,SG4,NAD,3042,,,,Straße und Hausnummer oderPostfach,X, - 127,Name und Anschrift Ansprechpartner Rahmenverträge,SG4,NAD,3164,,,,Ort,X, - 128,Name und Anschrift Ansprechpartner Rahmenverträge,SG4,NAD,3251,,,,Postleitzahl,M [2]S [3],"[2] Wenn der Code im DE3207 in der ""EDI@Energy Codeliste der europäischen Ländercodes"" in der Spalte ""PLZ vorhanden"" ein ""X"" enthält - [3] wenn vorhanden" - 129,Name und Anschrift Ansprechpartner Rahmenverträge,SG4,NAD,3207,,,,"Ländername, Code",X, - 130,Ansprechpartner,SG7,,,,,,,Muss, - 131,Ansprechpartner,SG7,CTA,,,,,,Muss, - 132,Ansprechpartner,SG7,CTA,3139,,IC,,Informationskontakt,X, - 133,Ansprechpartner,SG7,CTA,3412,,,,Name der organisatorischenEinheit,X [501],"[501] Hinweis: Es darf kein Name einer natürlichen Person übermittelt werden, stattdessen ist die organisatorische Einheit im Unternehmen zu nennen." - 134,Kommunikationsverbindung,SG7,COM,,,,,,Muss, - 135,Kommunikationsverbindung,SG7,COM,3148,,,,Nummer / Adresse,X (([939][6])∨ ([940][8]))∧ [502],"[6] wenn im DE3155 im demselben COM der Code EM vorhanden ist - [8] wenn im DE3155 im demselben COM der Code TE / FX vorhanden ist - [502] Hinweis: Es darf nur eine Information im DE3148 übermittelt werden" - 136,Kommunikationsverbindung,SG7,COM,3155,,EM,,Elektronische Post,X [1P1..1], - 137,Kommunikationsverbindung,SG7,COM,3155,,TE,,Telefon,X [1P1..1], - 138,Kommunikationsverbindung,SG7,COM,3155,,FX,,Telefax,X [1P0..1], - 139,Name und Anschrift Ansprechpartner Kündigungsprozess,SG4,,,,,,,Muss [10] ∧[22],"[5] Wenn MP-ID in SG2 NAD+MR (Nachrichtenempfänger) in der Rolle LF - [10] Wenn BGM DE1373 = 11 (Dokument nicht verfügbar) nicht vorhanden - [22] Wenn MP-ID in SG2 NAD+MR (Nachrichtenempfänger) in der Rolle MSB" - 140,Name und Anschrift Ansprechpartner Kündigungsprozess,SG4,NAD,,,,,,Muss, - 141,Name und Anschrift Ansprechpartner Kündigungsprozess,SG4,NAD,3035,,Z12,,AnsprechpartnerKündigungsprozesse,X, - 142,Name und Anschrift Ansprechpartner Kündigungsprozess,SG4,NAD,3036,,,,Name,X [500],[500] Hinweis: Es kann der Firmenname eines Dienstleisters oder die identische Firmenbezeichnung aus SG4 NAD+SU / DDM / DEB / Z31 / Z34 / Z35 / Z36 eingetragen werden. - 143,Name und Anschrift Ansprechpartner Kündigungsprozess,SG4,NAD,3045,,Z02,,Struktur derFirmenbezeichnung,X, - 144,Name und Anschrift Ansprechpartner Kündigungsprozess,SG4,NAD,3042,,,,Straße und Hausnummer oderPostfach,X, - 145,Name und Anschrift Ansprechpartner Kündigungsprozess,SG4,NAD,3164,,,,Ort,X, - 146,Name und Anschrift Ansprechpartner Kündigungsprozess,SG4,NAD,3251,,,,Postleitzahl,M [2]S [3],[2] Wenn der Code im DE3207 in der - 147,Name und Anschrift Ansprechpartner Kündigungsprozess,SG4,NAD,3207,,,,"Ländername, Code",X, - 148,Ansprechpartner,SG7,,,,,,,Muss, - 149,Ansprechpartner,SG7,CTA,,,,,,Muss, - 150,Ansprechpartner,SG7,CTA,3139,,IC,,Informationskontakt,X, - 151,Ansprechpartner,SG7,CTA,3412,,,,Name der organisatorischenEinheit,X [501],"[501] Hinweis: Es darf kein Name einer natürlichen Person übermittelt werden, stattdessen ist die organisatorische Einheit im Unternehmen zu nennen." - 152,Kommunikationsverbindung,SG7,COM,,,,,,Muss, - 153,Kommunikationsverbindung,SG7,COM,3148,,,,Nummer / Adresse,X (([939][6])∨ ([940][8]))∧ [502],"[6] wenn im DE3155 im demselben COM der Code EM vorhanden ist - [8] wenn im DE3155 im demselben COM der Code TE / FX vorhanden ist - [502] Hinweis: Es darf nur eine Information im DE3148 übermittelt werden - [939] Format: Die Zeichenkette muss die Zeichen @ und . enthalten - [940] Format: Die Zeichenkette muss mit dem Zeichen + beginnen und danach dürfen nur noch Ziffern folgen" - 154,Kommunikationsverbindung,SG7,COM,3155,,EM,,Elektronische Post,X [1P1..1], - 155,Kommunikationsverbindung,SG7,COM,3155,,TE,,Telefon,X [1P1..1], - 156,Name und Anschrift Ansprechpartner Wechselprozesse,SG4,,,,,,,Muss [10] ∧[17],"[10] Wenn BGM DE1373 = 11 (Dokument nicht verfügbar) nicht vorhanden - [17] Wenn MP-ID in SG2 NAD+MR (Nachrichtenempfänger) in der Rolle LF/NB/MSB" - 157,Name und Anschrift Ansprechpartner Wechselprozesse,SG4,NAD,,,,,,Muss, - 158,Name und Anschrift Ansprechpartner Wechselprozesse,SG4,NAD,3035,,Z13,,AnsprechpartnerWechselprozesse,X, - 159,Name und Anschrift Ansprechpartner Wechselprozesse,SG4,NAD,3036,,,,Name,X [500],[500] Hinweis: Es kann der Firmenname eines Dienstleisters oder die identische Firmenbezeichnung aus SG4 NAD+SU / DDM / DEB / Z31 / Z34 / Z35 / Z36 eingetragen werden. - 160,Name und Anschrift Ansprechpartner Wechselprozesse,SG4,NAD,3045,,Z02,,Struktur derFirmenbezeichnung,X, - 161,Name und Anschrift Ansprechpartner Wechselprozesse,SG4,NAD,3042,,,,Straße und Hausnummer oderPostfach,X, - 162,Name und Anschrift Ansprechpartner Wechselprozesse,SG4,NAD,3164,,,,Ort,X, - 163,Name und Anschrift Ansprechpartner Wechselprozesse,SG4,NAD,3251,,,,Postleitzahl,M [2]S [3],"[2] Wenn der Code im DE3207 in der ""EDI@Energy Codeliste der europäischen Ländercodes"" in der Spalte ""PLZ vorhanden"" ein ""X"" enthält - [3] wenn vorhanden" - 164,Name und Anschrift Ansprechpartner Wechselprozesse,SG4,NAD,3207,,,,"Ländername, Code",X, - 165,Ansprechpartner,SG7,,,,,,,Muss, - 166,Ansprechpartner,SG7,CTA,,,,,,Muss, - 167,Ansprechpartner,SG7,CTA,3139,,IC,,Informationskontakt,X, - 168,Ansprechpartner,SG7,CTA,3412,,,,Name der organisatorischenEinheit,X [501],"[501] Hinweis: Es darf kein Name einer natürlichen Person übermittelt werden, stattdessen ist die" - 169,Kommunikationsverbindung,SG7,COM,,,,,,Muss, - 170,Kommunikationsverbindung,SG7,COM,3148,,,,Nummer / Adresse,X (([939][6])∨ ([940][8]))∧ [502],"[6] wenn im DE3155 im demselben COM der Code EM vorhanden ist - [8] wenn im DE3155 im demselben COM der Code TE / FX vorhanden ist - [502] Hinweis: Es darf nur eine Information im DE3148 übermittelt werden - [939] Format: Die Zeichenkette muss die Zeichen @ und . enthalten - [940] Format: Die Zeichenkette muss mit dem Zeichen + beginnen und danach dürfen nur noch Ziffern folgen" - 171,Kommunikationsverbindung,SG7,COM,3155,,EM,,Elektronische Post,X [1P1..1], - 172,Kommunikationsverbindung,SG7,COM,3155,,TE,,Telefon,X [1P1..1], - 173,Kommunikationsverbindung,SG7,COM,3155,,FX,,Telefax,X [1P0..1], - 174,Name und Anschrift Ansprechpartner Stammdatenprozesse,SG4,,,,,,,Muss [10] ∧[19],"[10] Wenn BGM DE1373 = 11 (Dokument nicht verfügbar) nicht vorhanden - [19] Wenn MP-ID in SG2 NAD+MR (Nachrichtenempfänger) in der Rolle LF/MSB/ NB/ÜNB" - 175,Name und Anschrift Ansprechpartner Stammdatenprozesse,SG4,NAD,,,,,,Muss, - 176,Name und Anschrift Ansprechpartner Stammdatenprozesse,SG4,NAD,3035,,Z14,,AnsprechpartnerStammdatenprozesse,X, - 177,Name und Anschrift Ansprechpartner Stammdatenprozesse,SG4,NAD,3036,,,,Name,X [500],[500] Hinweis: Es kann der Firmenname eines Dienstleisters oder die identische Firmenbezeichnung aus SG4 NAD+SU / DDM / DEB / Z31 / Z34 / Z35 / Z36 eingetragen werden. - 178,Name und Anschrift Ansprechpartner Stammdatenprozesse,SG4,NAD,3045,,Z02,,Struktur derFirmenbezeichnung,X, - 179,Name und Anschrift Ansprechpartner Stammdatenprozesse,SG4,NAD,3042,,,,Straße und Hausnummer oderPostfach,X, - 180,Name und Anschrift Ansprechpartner Stammdatenprozesse,SG4,NAD,3164,,,,Ort,X, - 181,Name und Anschrift Ansprechpartner Stammdatenprozesse,SG4,NAD,3251,,,,Postleitzahl,M [2]S [3],"[2] Wenn der Code im DE3207 in der ""EDI@Energy Codeliste der europäischen Ländercodes"" in der Spalte ""PLZ vorhanden"" ein ""X"" enthält - [3] wenn vorhanden" - 182,Name und Anschrift Ansprechpartner Stammdatenprozesse,SG4,NAD,3207,,,,"Ländername, Code",X, - 183,Ansprechpartner,SG7,,,,,,,Muss, - 184,Ansprechpartner,SG7,CTA,,,,,,Muss, - 185,Ansprechpartner,SG7,CTA,3139,,IC,,Informationskontakt,X, - 186,Ansprechpartner,SG7,CTA,3412,,,,Name der organisatorischenEinheit,X [501],"[501] Hinweis: Es darf kein Name einer natürlichen Person übermittelt werden, stattdessen ist die organisatorische Einheit im Unternehmen zu nennen." - 187,Kommunikationsverbindung,SG7,COM,,,,,,Muss, - 188,Kommunikationsverbindung,SG7,COM,3148,,,,Nummer / Adresse,X (([939][6])∨ ([940][8]))∧ [502],"[6] wenn im DE3155 im demselben COM der Code EM vorhanden ist - [8] wenn im DE3155 im demselben COM der Code TE / FX vorhanden ist - [502] Hinweis: Es darf" - 189,Kommunikationsverbindung,SG7,COM,3155,,EM,,Elektronische Post,X [1P1..1], - 190,Kommunikationsverbindung,SG7,COM,3155,,TE,,Telefon,X [1P1..1], - 191,Kommunikationsverbindung,SG7,COM,3155,,FX,,Telefax,X [1P0..1], - 192,Name und Anschrift Ansprechpartner Einspeiseprozesse,SG4,,,,,,,Muss [10] ∧[23],"[10] Wenn BGM DE1373 = 11 (Dokument nicht verfügbar) nicht vorhanden - [17] Wenn MP-ID in SG2 NAD+MR (Nachrichtenempfänger) in der Rolle LF/NB/MSB - [18] Wenn MP-ID in SG2 NAD+MR (Nachrichtenempfänger) in der Rolle LF/MSB - [23] Wenn MP-ID in SG2 NAD+MR (Nachrichtenempfänger) in der Rolle NB/ÜNB" - 193,Name und Anschrift Ansprechpartner Einspeiseprozesse,SG4,NAD,,,,,,Muss, - 194,Name und Anschrift Ansprechpartner Einspeiseprozesse,SG4,NAD,3035,,Z16,,AnsprechpartnerEinspeiseprozesse,X, - 195,Name und Anschrift Ansprechpartner Einspeiseprozesse,SG4,NAD,3036,,,,Name,X [500],[500] Hinweis: Es kann der Firmenname eines Dienstleisters oder die identische Firmenbezeichnung aus SG4 NAD+SU / DDM / DEB / Z31 / Z34 / Z35 / Z36 eingetragen werden. - 196,Name und Anschrift Ansprechpartner Einspeiseprozesse,SG4,NAD,3045,,Z02,,Struktur derFirmenbezeichnung,X, - 197,Name und Anschrift Ansprechpartner Einspeiseprozesse,SG4,NAD,3042,,,,Straße und Hausnummer oderPostfach,X, - 198,Name und Anschrift Ansprechpartner Einspeiseprozesse,SG4,NAD,3164,,,,Ort,X, - 199,Name und Anschrift Ansprechpartner Einspeiseprozesse,SG4,NAD,3251,,,,Postleitzahl,M [2]S [3],"[2] Wenn der Code im DE3207 in der ""EDI@Energy Codeliste der europäischen Ländercodes"" in der Spalte ""PLZ vorhanden"" ein ""X"" enthält - [3] wenn vorhanden" - 200,Name und Anschrift Ansprechpartner Einspeiseprozesse,SG4,NAD,3207,,,,"Ländername, Code",X, - 201,Ansprechpartner,SG7,,,,,,,Muss, - 202,Ansprechpartner,SG7,CTA,,,,,,Muss, - 203,Ansprechpartner,SG7,CTA,3139,,IC,,Informationskontakt,X, - 204,Ansprechpartner,SG7,CTA,3412,,,,Name der organisatorischenEinheit,X [501],"[501] Hinweis: Es darf kein Name einer natürlichen Person übermittelt werden, stattdessen ist die organisatorische Einheit im Unternehmen zu nennen." - 205,Kommunikationsverbindung,SG7,COM,,,,,,Muss, - 206,Kommunikationsverbindung,SG7,COM,3148,,,,Nummer / Adresse,X (([939][6])∨ ([940][8]))∧ [502],"[6] wenn im DE3155 im demselben COM der Code EM vorhanden ist - [8] wenn im DE3155 im demselben COM der Code TE / FX vorhanden ist - [502] Hinweis: Es darf nur eine Information im DE3148 übermittelt werden - [939] Format: Die Zeichenkette muss die Zeichen @ und . enthalten " - 207,Kommunikationsverbindung,SG7,COM,3155,,EM,,Elektronische Post,X [1P1..1], - 208,Kommunikationsverbindung,SG7,COM,3155,,TE,,Telefon,X [1P1..1], - 209,Kommunikationsverbindung,SG7,COM,3155,,FX,,Telefax,X [1P0..1], - 210,Name und Anschrift Ansprechpartner Abrechnungsprozesse,SG4,,,,,,,Muss [10] ∧[24],"[10] Wenn BGM DE1373 = 11 (Dokument nicht verfügbar) nicht vorhanden - [17] Wenn MP-ID in SG2 NAD+MR (Nachrichtenempfänger) in der Rolle LF/NB/MSB - [18] Wenn MP-ID in SG2 NAD+MR (Nachrichtenempfänger) in der Rolle LF/MSB - [24] Wenn MP-ID in SG2 NAD+MR (Nachrichtenempfänger) in der Rolle NB/LF/ MSB/ESA" - 211,Name und Anschrift Ansprechpartner Abrechnungsprozesse,SG4,NAD,,,,,,Muss, - 212,Name und Anschrift Ansprechpartner Abrechnungsprozesse,SG4,NAD,3035,,Z17,,AnsprechpartnerAbrechnungsprozesse,X, - 213,Name und Anschrift Ansprechpartner Abrechnungsprozesse,SG4,NAD,3036,,,,Name,X [500],[500] Hinweis: Es kann der Firmenname eines Dienstleisters oder die identische Firmenbezeichnung aus SG4 NAD+SU / DDM / DEB / Z31 / Z34 / Z35 / Z36 eingetragen werden. - 214,Name und Anschrift Ansprechpartner Abrechnungsprozesse,SG4,NAD,3045,,Z02,,Struktur derFirmenbezeichnung,X, - 215,Name und Anschrift Ansprechpartner Abrechnungsprozesse,SG4,NAD,3042,,,,Straße und Hausnummer oderPostfach,X, - 216,Name und Anschrift Ansprechpartner Abrechnungsprozesse,SG4,NAD,3164,,,,Ort,X, - 217,Name und Anschrift Ansprechpartner Abrechnungsprozesse,SG4,NAD,3251,,,,Postleitzahl,M [2]S [3],[2] Wenn der Code im DE3207 in der - 218,Name und Anschrift Ansprechpartner Abrechnungsprozesse,SG4,NAD,3207,,,,"Ländername, Code",X, - 219,Ansprechpartner,SG7,,,,,,,Muss, - 220,Ansprechpartner,SG7,CTA,,,,,,Muss, - 221,Ansprechpartner,SG7,CTA,3139,,IC,,Informationskontakt,X, - 222,Ansprechpartner,SG7,CTA,3412,,,,Name der organisatorischenEinheit,X [501],"[501] Hinweis: Es darf kein Name einer natürlichen Person übermittelt werden, stattdessen ist die organisatorische Einheit im Unternehmen zu nennen." - 223,Kommunikationsverbindung,SG7,COM,,,,,,Muss, - 224,Kommunikationsverbindung,SG7,COM,3148,,,,Nummer / Adresse,X (([939][6])∨ ([940][8]))∧ [502],"[6] wenn im DE3155 im demselben COM der Code EM vorhanden ist - [8] wenn im DE3155 im demselben COM der Code TE / FX vorhanden ist - [502] Hinweis: Es darf nur eine Information im DE3148 übermittelt werden - [939] Format: Die Zeichenkette muss die Zeichen @ und . enthalten - [940] Format: Die Zeichenkette muss mit dem Zeichen + beginnen und danach dürfen nur noch Ziffern folgen" - 225,Kommunikationsverbindung,SG7,COM,3155,,EM,,Elektronische Post,X [1P1..1], - 226,Kommunikationsverbindung,SG7,COM,3155,,TE,,Telefon,X [1P1..1], - 227,Name und Anschrift Ansprechpartner MMMA- Prozesse,SG4,,,,,,,,"[10] Wenn BGM DE1373 = 11 (Dokument nicht verfügbar) nicht vorhanden - [17] Wenn MP-ID in SG2 NAD+MR (Nachrichtenempfänger) in der Rolle LF/NB/MSB - [20] Wenn MP-ID in SG2 NAD+MR (Nachrichtenempfänger) in der Rolle LF/MSB/ÜNB" - 228,Name und Anschrift Ansprechpartner MMMA- Prozesse,SG4,NAD,,,,,,, - 229,Name und Anschrift Ansprechpartner MMMA- Prozesse,SG4,NAD,3035,,Z18,,AnsprechpartnerMMMA-Prozesse,, - 230,Name und Anschrift Ansprechpartner MMMA- Prozesse,SG4,NAD,3036,,,,Name,,[500] Hinweis: Es kann der Firmenname eines Dienstleisters oder die identische Firmenbezeichnung aus SG4 NAD+SU / DDM / DEB / Z31 / Z34 / Z35 / Z36 eingetragen werden. - 231,Name und Anschrift Ansprechpartner MMMA- Prozesse,SG4,NAD,3045,,Z02,,Struktur derFirmenbezeichnung,, - 232,Name und Anschrift Ansprechpartner MMMA- Prozesse,SG4,NAD,3042,,,,Straße und Hausnummer oderPostfach,, - 233,Name und Anschrift Ansprechpartner MMMA- Prozesse,SG4,NAD,3164,,,,Ort,, - 234,Name und Anschrift Ansprechpartner MMMA- Prozesse,SG4,NAD,3251,,,,Postleitzahl,,"[2] Wenn der Code im DE3207 in der ""EDI@Energy Codeliste der europäischen Ländercodes"" in der Spalte ""PLZ vorhanden"" ein ""X"" enthält - [3] wenn vorhanden" - 235,Name und Anschrift Ansprechpartner MMMA- Prozesse,SG4,NAD,3207,,,,"Ländername, Code",, - 236,Ansprechpartner,SG7,,,,,,,, - 237,Ansprechpartner,SG7,CTA,,,,,,, - 238,Ansprechpartner,SG7,CTA,3139,,IC,,Informationskontakt,, - 239,Ansprechpartner,SG7,CTA,3412,,,,Name der organisatorischenEinheit,,"[501] Hinweis: Es darf kein Name einer natürlichen Person übermittelt werden, stattdessen ist die organisatorische Einheit im Unternehmen zu nennen." - 240,Kommunikationsverbindung,SG7,COM,,,,,,, - 241,Kommunikationsverbindung,SG7,COM,3148,,,,Nummer / Adresse,,"[6] wenn im DE3155 im demselben COM der Code EM vorhanden ist - [8] wenn im DE3155 im demselben COM der Code TE / FX vorhanden ist - [502] Hinweis: Es darf nur eine Information im DE3148 übermittelt werden - [939] Format: Die Zeichenkette muss die Zeichen @ und . enthalten - [940] Format: Die Zeichenkette muss mit dem Zeichen + beginnen und danach dürfen nur noch Ziffern folgen" - 242,Kommunikationsverbindung,SG7,COM,3155,,EM,,Elektronische Post,, - 243,Kommunikationsverbindung,SG7,COM,3155,,TE,,Telefon,, - 244,Kommunikationsverbindung,SG7,COM,3155,,FX,,Telefax,, - 245,Name und Anschrift Bewegungsdaten,SG4,,,,,,,Muss [10],"[10] Wenn BGM DE1373 = 11 (Dokument nicht verfügbar) nicht vorhanden - [19] Wenn MP-ID in SG2 NAD+MR (Nachrichtenempfänger) in der Rolle LF/MSB/" - 246,Name und Anschrift Bewegungsdaten,SG4,NAD,,,,,,Muss, - 247,Name und Anschrift Bewegungsdaten,SG4,NAD,3035,,Z19,,AnsprechpartnerBewegungsdaten,X, - 248,Name und Anschrift Bewegungsdaten,SG4,NAD,3036,,,,Name,X [500],[500] Hinweis: Es kann der Firmenname eines Dienstleisters oder die identische Firmenbezeichnung aus SG4 NAD+SU / DDM / DEB / Z31 / Z34 / Z35 / Z36 eingetragen werden. - 249,Name und Anschrift Bewegungsdaten,SG4,NAD,3045,,Z02,,Struktur derFirmenbezeichnung,X, - 250,Name und Anschrift Bewegungsdaten,SG4,NAD,3042,,,,Straße und Hausnummer oderPostfach,X, - 251,Name und Anschrift Bewegungsdaten,SG4,NAD,3164,,,,Ort,X, - 252,Name und Anschrift Bewegungsdaten,SG4,NAD,3251,,,,Postleitzahl,M [2]S [3],"[2] Wenn der Code im DE3207 in der ""EDI@Energy Codeliste der europäischen Ländercodes"" in der Spalte ""PLZ vorhanden"" ein ""X"" enthält - [3] wenn vorhanden" - 253,Name und Anschrift Bewegungsdaten,SG4,NAD,3207,,,,"Ländername, Code",X, - 254,Ansprechpartner,SG7,,,,,,,Muss, - 255,Ansprechpartner,SG7,CTA,,,,,,Muss, - 256,Ansprechpartner,SG7,CTA,3139,,IC,,Informationskontakt,X, - 257,Ansprechpartner,SG7,CTA,3412,,,,Name der organisatorischenEinheit,X [501],"[501] Hinweis: Es darf kein Name einer natürlichen Person übermittelt werden, stattdessen ist die organisatorische Einheit im Unternehmen zu nennen." - 258,Kommunikationsverbindung,SG7,COM,,,,,,Muss, - 259,Kommunikationsverbindung,SG7,COM,3148,,,,Nummer / Adresse,X (([939][6])∨ ([940][8]))∧ [502],"[6] wenn im DE3155 im demselben COM der Code EM vorhanden ist - [8] wenn im DE3155 im demselben COM der" - 260,Kommunikationsverbindung,SG7,COM,3155,,EM,,Elektronische Post,X [1P1..1], - 261,Kommunikationsverbindung,SG7,COM,3155,,TE,,Telefon,X [1P1..1], - 262,Kommunikationsverbindung,SG7,COM,3155,,FX,,Telefax,X [1P0..1], - 263,Name und Anschrift Ansprechpartner Prozesse zur Unterbrechung und Wiederherstellung der Anschlussnutzung,SG4,,,,,,,,"[10] Wenn BGM DE1373 = 11 (Dokument nicht verfügbar) nicht vorhanden - [17] Wenn MP-ID in SG2 NAD+MR (Nachrichtenempfänger) in der Rolle LF/NB/MSB - [20] Wenn MP-ID in SG2 NAD+MR (Nachrichtenempfänger) in der Rolle LF/MSB/ÜNB" - 264,Name und Anschrift Ansprechpartner Prozesse zur Unterbrechung und Wiederherstellung der Anschlussnutzung,SG4,NAD,,,,,,, - 265,Name und Anschrift Ansprechpartner Prozesse zur Unterbrechung und Wiederherstellung der Anschlussnutzung,SG4,NAD,3035,,Z20,,AnsprechpartnerSperr-/Entsperrprozesse,, - 266,Name und Anschrift Ansprechpartner Prozesse zur Unterbrechung und Wiederherstellung der Anschlussnutzung,SG4,NAD,3036,,,,Name,,[500] Hinweis: Es kann der Firmenname eines Dienstleisters oder die identische Firmenbezeichnung aus SG4 NAD+SU / DDM / DEB / Z31 / Z34 / Z35 / - 267,Name und Anschrift Ansprechpartner Prozesse zur Unterbrechung und Wiederherstellung der Anschlussnutzung,SG4,NAD,3045,,Z02,,Struktur derFirmenbezeichnung,, - 268,Name und Anschrift Ansprechpartner Prozesse zur Unterbrechung und Wiederherstellung der Anschlussnutzung,SG4,NAD,3042,,,,Straße und Hausnummer oderPostfach,, - 269,Name und Anschrift Ansprechpartner Prozesse zur Unterbrechung und Wiederherstellung der Anschlussnutzung,SG4,NAD,3164,,,,Ort,, - 270,Name und Anschrift Ansprechpartner Prozesse zur Unterbrechung und Wiederherstellung der Anschlussnutzung,SG4,NAD,3251,,,,Postleitzahl,,"[2] Wenn der Code im DE3207 in der ""EDI@Energy Codeliste der europäischen Ländercodes"" in der Spalte ""PLZ vorhanden"" ein ""X"" enthält - [3] wenn vorhanden" - 271,Name und Anschrift Ansprechpartner Prozesse zur Unterbrechung und Wiederherstellung der Anschlussnutzung,SG4,NAD,3207,,,,"Ländername, Code",, - 272,Ansprechpartner,SG7,,,,,,,, - 273,Ansprechpartner,SG7,CTA,,,,,,, - 274,Ansprechpartner,SG7,CTA,3139,,IC,,Informationskontakt,, - 275,Ansprechpartner,SG7,CTA,3412,,,,Name der organisatorischenEinheit,,"[501] Hinweis: Es darf kein Name einer natürlichen Person übermittelt werden, stattdessen ist die organisatorische Einheit im Unternehmen zu nennen." - 276,Kommunikationsverbindung,SG7,COM,,,,,,, - 277,Kommunikationsverbindung,SG7,COM,3148,,,,Nummer / Adresse,,"[6] wenn im DE3155 im demselben COM der Code EM vorhanden ist - [8] wenn im DE3155 im demselben COM der Code TE / FX vorhanden ist - [502] Hinweis: Es darf nur eine Information im DE3148 übermittelt werden - [939] Format: Die Zeichenkette muss die Zeichen @ und ." - 278,Kommunikationsverbindung,SG7,COM,3155,,EM,,Elektronische Post,, - 279,Kommunikationsverbindung,SG7,COM,3155,,TE,,Telefon,, - 280,Kommunikationsverbindung,SG7,COM,3155,,FX,,Telefax,, - 281,Name und Anschrift Ansprechpartner Bilanzierungsprozesse / Bilanzkreismanagement,SG4,,,,,,,,[10] Wenn BGM DE1373 = 11 (Dokument nicht verfügbar) nicht vorhanden - 282,Name und Anschrift Ansprechpartner Bilanzierungsprozesse / Bilanzkreismanagement,SG4,NAD,,,,,,, - 283,Name und Anschrift Ansprechpartner Bilanzierungsprozesse / Bilanzkreismanagement,SG4,NAD,3035,,Z21,,AnsprechpartnerBilanzierungsprozesse /Bilanzkreismanagement,, - 284,Name und Anschrift Ansprechpartner Bilanzierungsprozesse / Bilanzkreismanagement,SG4,NAD,3036,,,,Name,,[500] Hinweis: Es kann der Firmenname eines Dienstleisters oder die identische Firmenbezeichnung aus SG4 NAD+SU / DDM / DEB / Z31 / Z34 / Z35 / Z36 eingetragen werden. - 285,Name und Anschrift Ansprechpartner Bilanzierungsprozesse / Bilanzkreismanagement,SG4,NAD,3045,,Z02,,Struktur derFirmenbezeichnung,, - 286,Name und Anschrift Ansprechpartner Bilanzierungsprozesse / Bilanzkreismanagement,SG4,NAD,3042,,,,Straße und Hausnummer oderPostfach,, - 287,Name und Anschrift Ansprechpartner Bilanzierungsprozesse / Bilanzkreismanagement,SG4,NAD,3164,,,,Ort,, - 288,Name und Anschrift Ansprechpartner Bilanzierungsprozesse / Bilanzkreismanagement,SG4,NAD,3251,,,,Postleitzahl,,"[2] Wenn der Code im DE3207 in der ""EDI@Energy Codeliste der europäischen Ländercodes"" in der Spalte ""PLZ vorhanden"" ein ""X"" enthält - [3] wenn vorhanden" - 289,Name und Anschrift Ansprechpartner Bilanzierungsprozesse / Bilanzkreismanagement,SG4,NAD,3207,,,,"Ländername, Code",, - 290,Ansprechpartner,SG7,,,,,,,, - 291,Ansprechpartner,SG7,CTA,,,,,,, - 292,Ansprechpartner,SG7,CTA,3139,,IC,,Informationskontakt,, - 293,Ansprechpartner,SG7,CTA,3412,,,,Name der organisatorischenEinheit,,"[501] Hinweis: Es darf kein Name einer natürlichen Person übermittelt werden, stattdessen ist die organisatorische Einheit im Unternehmen zu nennen." - 294,Kommunikationsverbindung,SG7,COM,,,,,,, - 295,Kommunikationsverbindung,SG7,COM,3148,,,,Nummer / Adresse,,"[6] wenn im DE3155 im demselben COM der Code EM vorhanden ist - [8] wenn im DE3155 im demselben COM der Code TE / FX vorhanden ist - [502] Hinweis: Es darf nur eine Information im DE3148 übermittelt werden - [939] Format: Die Zeichenkette muss die Zeichen @ und . enthalten - [940] Format: Die Zeichenkette muss mit dem Zeichen + beginnen und danach dürfen nur noch Ziffern folgen" - 296,Kommunikationsverbindung,SG7,COM,3155,,EM,,Elektronische Post,, - 297,Kommunikationsverbindung,SG7,COM,3155,,TE,,Telefon,, - 298,Kommunikationsverbindung,SG7,COM,3155,,FX,,Telefax,, - 299,Name und Anschrift Ansprechpartner Technischer Netzanschluss für Neuanlagen und Anlagenumbau,SG4,,,,,,,,[10] Wenn BGM DE1373 = 11 (Dokument nicht verfügbar) nicht vorhanden - 300,Name und Anschrift Ansprechpartner Technischer Netzanschluss für Neuanlagen und Anlagenumbau,SG4,NAD,,,,,,, - 301,Name und Anschrift Ansprechpartner Technischer Netzanschluss für Neuanlagen und Anlagenumbau,SG4,NAD,3035,,Z33,,AnsprechpartnertechnischerNetzanschluss fürNeuanlagen undAnlagenumbau,, - 302,Name und Anschrift Ansprechpartner Technischer Netzanschluss für Neuanlagen und Anlagenumbau,SG4,NAD,3036,,,,Name,,[500] Hinweis: Es kann der Firmenname eines Dienstleisters oder die identische Firmenbezeichnung aus SG4 NAD+SU / DDM / DEB / Z31 / Z34 / Z35 / Z36 eingetragen werden. - 303,Name und Anschrift Ansprechpartner Technischer Netzanschluss für Neuanlagen und Anlagenumbau,SG4,NAD,3045,,Z02,,Struktur derFirmenbezeichnung,, - 304,Name und Anschrift Ansprechpartner Technischer Netzanschluss für Neuanlagen und Anlagenumbau,SG4,NAD,3042,,,,Straße und Hausnummer oderPostfach,, - 305,Name und Anschrift Ansprechpartner Technischer Netzanschluss für Neuanlagen und Anlagenumbau,SG4,NAD,3164,,,,Ort,, - 306,Name und Anschrift Ansprechpartner Technischer Netzanschluss für Neuanlagen und Anlagenumbau,SG4,NAD,3251,,,,Postleitzahl,,"[2] Wenn der Code im DE3207 in der ""EDI@Energy Codeliste der europäischen Ländercodes"" in der Spalte ""PLZ vorhanden"" ein ""X"" enthält - [3] wenn vorhanden" - 307,Name und Anschrift Ansprechpartner Technischer Netzanschluss für Neuanlagen und Anlagenumbau,SG4,NAD,3207,,,,"Ländername, Code",, - 308,Ansprechpartner,SG7,,,,,,,, - 309,Ansprechpartner,SG7,CTA,,,,,,, - 310,Ansprechpartner,SG7,CTA,3139,,IC,,Informationskontakt,, - 311,Ansprechpartner,SG7,CTA,3412,,,,Name der organisatorischenEinheit,,"[501] Hinweis: Es darf kein Name einer natürlichen Person übermittelt werden, stattdessen ist die organisatorische Einheit im Unternehmen zu nennen." - 312,Kommunikationsverbindung,SG7,COM,,,,,,, - 313,Kommunikationsverbindung,SG7,COM,3148,,,,Nummer / Adresse,,"[6] wenn im DE3155 im demselben COM der Code EM vorhanden ist - [8] wenn im DE3155 im demselben COM der Code TE / FX vorhanden ist - [502] Hinweis: Es darf nur eine Information im DE3148 übermittelt werden - [939] Format: Die Zeichenkette muss die Zeichen @ und . enthalten - [940] Format: Die Zeichenkette muss mit dem Zeichen + beginnen und danach dürfen nur noch Ziffern folgen" - 314,Kommunikationsverbindung,SG7,COM,3155,,EM,,Elektronische Post,, - 315,Kommunikationsverbindung,SG7,COM,3155,,TE,,Telefon,, - 316,Kommunikationsverbindung,SG7,COM,3155,,FX,,Telefax,, - 317,Nachrichten-Endesegment,,UNT,,,,,,Muss, - 318,Nachrichten-Endesegment,,UNT,0074,,,,Anzahl der Segmente in einerNachricht,X, - 319,Nachrichten-Endesegment,,UNT,0062,,,,Nachrichten-Referenznummer,X, - - ''', - '37003.csv': ''' - ,Segmentname,Segmentgruppe,Segment,Datenelement,Segment ID,Code,Qualifier,Beschreibung,Bedingungsausdruck,Bedingung - 0,Nachrichten-Kopfsegment,,UNH,,,,,,Muss, - 1,Nachrichten-Kopfsegment,,UNH,0062,,,,Nachrichten-Referenznummer,X, - 2,Nachrichten-Kopfsegment,,UNH,0065,,PARTIN,,Partnerstammdaten,X, - 3,Nachrichten-Kopfsegment,,UNH,0052,,D,,Entwurfs-Version,X, - 4,Nachrichten-Kopfsegment,,UNH,0054,,20B,,Ausgabe 2020 - B,X, - 5,Nachrichten-Kopfsegment,,UNH,0051,,UN,,UN/CEFACT,X, - 6,Nachrichten-Kopfsegment,,UNH,0057,,1.0c,,Versionsnummer derzugrundeliegendenBDEW-Nachrichtenbeschreibung,X, - 7,Beginn der Nachricht,,BGM,,,,,,Muss, - 8,Beginn der Nachricht,,BGM,1001,,10,,Partnerstammdaten,X, - 9,Beginn der Nachricht,,BGM,1004,,,,Dokumentennummer,X, - 10,Beginn der Nachricht,,BGM,1373,,11,,Dokument nichtverfügbar,S [9],[9] Wenn die Kommunikationsdaten vom Absender nicht mehr aktiv sind. - 11,Nachrichtendatum,,DTM,,,,,,Muss, - 12,Nachrichtendatum,,DTM,2005,,137,,Dokumenten-/Nachrichtendatum/-zeit,X, - 13,Nachrichtendatum,,DTM,2380,,,,"Datum oder Uhrzeit oderZeitspanne, Wert",X [931][494],"[494] Das hier genannte Datum muss der Zeitpunkt sein, zu dem das Dokument erstellt wurde, oder ein Zeitpunkt, der davor liegt. - [931] Format: ZZZ = +00" - 14,Nachrichtendatum,,DTM,2379,,303,,CCYYMMDDHHMMZZZ,X, - 15,Prüfidentifikator,SG1,,,,,,,Muss, - 16,Prüfidentifikator,SG1,RFF,,,,,,Muss, - 17,Prüfidentifikator,SG1,RFF,1153,,Z13,,Prüfidentifikator,X, - 18,Prüfidentifikator,SG1,RFF,1154,,37003,,ÜbermittlungKommunikationsdatendes BKV,X, - 19,Prüfidentifikator,SG1,RFF,1154,,37004,,ÜbermittlungKommunikationsdatendes BIKO,, - 20,Prüfidentifikator,SG1,RFF,1154,,37005,,ÜbermittlungKommunikationsdatendes ÜNB,, - 21,Versionsnummer,SG1,,,,,,,Muss, - 22,Versionsnummer,SG1,RFF,,,,,,Muss, - 23,Versionsnummer,SG1,RFF,1153,,AGK,,Anwendungsreferenznummer,X, - 24,Versionsnummer,SG1,RFF,1056,,,,Versionsnummer,X [908][505],"[505] Wenn eine Vorgängerversion (RFF+ACW) angegeben ist, so muss der Wert in diesem DE1056 mindestens um 1 höher sein, als der Wert aus DE1056 der Vorgängerversion (RFF+ACW). - [908] Format: Mögliche Werte: 1 bis n" - 25,Gültig Ab,SG1,DTM,,,,,,Soll [4],[4] Wenn Vorgängerversion vorhanden - 26,Gültig Ab,SG1,DTM,2005,,157,,"Gültigkeit, Beginndatum",X, - 27,Gültig Ab,SG1,DTM,2380,,,,"Datum oder Uhrzeit oderZeitspanne, Wert",X [UB1], - 28,Gültig Ab,SG1,DTM,2379,,303,,CCYYMMDDHHMMZZZ,X, - 29,Vorgängerversion,SG1,,,,,,,Soll [4],[4] Wenn Vorgängerversion vorhanden - 30,Vorgängerversion,SG1,RFF,,,,,,Muss, - 31,Vorgängerversion,SG1,RFF,1153,,ACW,,Referenznummer einervorangegangenenNachricht,X, - 32,Vorgängerversion,SG1,RFF,1056,,,,Versionsnummer,X [908],[908] Format: Mögliche Werte: 1 bis n - 33,MP-ID Absender,SG2,,,,,,,Muss, - 34,MP-ID Absender,SG2,NAD,,,,,,Muss, - 35,MP-ID Absender,SG2,NAD,3035,,MS,,Dokumenten-/Nachrichtenausstellerbzw. -absender,X, - 36,MP-ID Absender,SG2,NAD,3039,,,,MP-ID,X [1],[1] Nur MP-ID aus Sparte Strom - 37,MP-ID Absender,SG2,NAD,3055,,9,,GS1,X, - 38,MP-ID Absender,SG2,NAD,3055,,293,,"DE, BDEW",X, - 39,Ansprechpartner,SG3,,,,,,,Kann, - 40,Ansprechpartner,SG3,CTA,,,,,,Muss, - 41,Ansprechpartner,SG3,CTA,3139,,IC,,Informationskontakt,X, - 42,Ansprechpartner,SG3,CTA,3412,,,,Name vom Ansprechpartner,X, - 43,Kommunikationsverbindung,SG3,COM,,,,,,Muss, - 44,Kommunikationsverbindung,SG3,COM,3148,,,,Nummer / Adresse,X (([939][6])∨ ([940][7]))∧ [502],"[6] wenn im DE3155 im demselben COM der Code EM vorhanden ist - [7] wenn im DE3155 im demselben COM der Code TE / FX / AJ / AL vorhanden ist - [502] Hinweis: Es darf nur eine Information im DE3148 übermittelt werden - [939] Format: Die Zeichenkette muss die Zeichen @ und . enthalten - [940] Format: Die Zeichenkette muss mit dem Zeichen + beginnen und danach dürfen nur noch Ziffern folgen" - 45,Kommunikationsverbindung,SG3,COM,3155,,EM,,Elektronische Post,X [1P0..1], - 46,Kommunikationsverbindung,SG3,COM,3155,,FX,,Telefax,X [1P0..1], - 47,Kommunikationsverbindung,SG3,COM,3155,,TE,,Telefon,X [1P0..1], - 48,Kommunikationsverbindung,SG3,COM,3155,,AJ,,weiteres Telefon,X [1P0..1], - 49,Kommunikationsverbindung,SG3,COM,3155,,AL,,Handy,X [1P0..1], - 50,MP-ID Empfänger,SG2,,,,,,,Muss, - 51,MP-ID Empfänger,SG2,NAD,,,,,,Muss, - 52,MP-ID Empfänger,SG2,NAD,3035,,MR,,Nachrichtenempfänger,X, - 53,MP-ID Empfänger,SG2,NAD,3039,,,,MP-ID,X [1],[1] Nur MP-ID aus Sparte Strom - 54,MP-ID Empfänger,SG2,NAD,3055,,9,,GS1,X, - 55,MP-ID Empfänger,SG2,NAD,3055,,293,,"DE, BDEW",X, - 56,Abschnitts-Kontrollsegment,,UNS,,,,,,Muss, - 57,Abschnitts-Kontrollsegment,,UNS,0081,,D,,Trennung von Kopf- undPositionsteil,X, - 58,Name und Adresse des Unternehmens,SG4,,,,,,,Muss [10],[10] Wenn BGM DE1373 = 11 (Dokument nicht verfügbar) nicht vorhanden - 59,Name und Adresse des Unternehmens,SG4,NAD,,,,,,Muss, - 60,Name und Adresse des Unternehmens,SG4,NAD,3035,,Z31,,Übertragungsnetzbetreiber,, - 61,Name und Adresse des Unternehmens,SG4,NAD,3035,,Z34,,Bilanzkoordinator,, - 62,Name und Adresse des Unternehmens,SG4,NAD,3035,,Z35,,Bilanzkreisverantwortlicher,X, - 63,Name und Adresse des Unternehmens,SG4,NAD,3036,,,,Name,X [506],"[506] Hinweis: Das Datenelement ist so zu füllen, dass sein Inhalt den Vorgaben des USt.- Gesetzes genügt, so dass der Empfänger diese Daten in einer INVOIC nutzen kann." - 64,Name und Adresse des Unternehmens,SG4,NAD,3045,,Z02,,Struktur derFirmenbezeichnung,X, - 65,Name und Adresse des Unternehmens,SG4,NAD,3042,,,,Straße und Hausnummer oderPostfach,X [506],"[506] Hinweis: Das Datenelement ist so zu füllen, dass sein Inhalt den Vorgaben des USt.- Gesetzes genügt, so dass der Empfänger diese Daten in einer INVOIC nutzen kann." - 66,Name und Adresse des Unternehmens,SG4,NAD,3164,,,,Ort,X [506],"[506] Hinweis: Das Datenelement ist so zu füllen, dass sein Inhalt den Vorgaben des USt.- Gesetzes genügt, so dass der Empfänger diese Daten in einer INVOIC nutzen kann." - 67,Name und Adresse des Unternehmens,SG4,NAD,3251,,,,Postleitzahl,M [2] ∧[506]S [3] ∧ [506],"[2] Wenn der Code im DE3207 in der ""EDI@Energy Codeliste der europäischen" - 68,Name und Adresse des Unternehmens,SG4,NAD,3207,,,,"Ländername, Code",X [506],"[506] Hinweis: Das Datenelement ist so zu füllen, dass sein Inhalt den Vorgaben des USt.- Gesetzes genügt, so dass der Empfänger diese Daten in einer INVOIC nutzen kann." - 69,Bankverbindung,SG4,FII,,,,,,Muss, - 70,Bankverbindung,SG4,FII,3035,,BK,,Kreditinstitut,X, - 71,Bankverbindung,SG4,FII,3194,,IBAN,,,X, - 72,Bankverbindung,SG4,FII,3192,,,,Name des Kontoinhabers,X, - 73,Bankverbindung,SG4,FII,3192,,,,Name des Kontoinhabers,K, - 74,Bankverbindung,SG4,FII,3433,,BIC,,,X, - 75,Bankverbindung,SG4,FII,3432,,,,Name des Kredinstituts,X, - 76,Internetseite (URL),SG4,FTX,,,,,,Muss, - 77,Internetseite (URL),SG4,FTX,4451,,Z13,,Internetseite,X, - 78,Internetseite (URL),SG4,FTX,4440,,,,Internetseite,X, - 79,Gericht und Handelsregister-Nummer,SG4,FTX,,,,,,Soll [3],[3] wenn vorhanden - 80,Gericht und Handelsregister-Nummer,SG4,FTX,4451,,Z15,,Gericht undHandelsregister-Nummer,X, - 81,Gericht und Handelsregister-Nummer,SG4,FTX,4440,,,,Gericht,X, - 82,Gericht und Handelsregister-Nummer,SG4,FTX,4440,,,,Handelsregister-Nummer,X, - 83,"Steuernummer, Umsatzsteuernummer",SG6,,,,,,,Muss, - 84,"Steuernummer, Umsatzsteuernummer",SG6,RFF,,,,,,Muss, - 85,"Steuernummer, Umsatzsteuernummer",SG6,RFF,1153,,VA,,Umsatzsteuernummer,X [2P0..1] ⊻[3P1..1], - 86,"Steuernummer, Umsatzsteuernummer",SG6,RFF,1153,,FC,,Steuernummer,X [2P0..1], - 87,"Steuernummer, Umsatzsteuernummer",SG6,RFF,1154,,,,"Referenz, Identifikation",X, - 88,Faxnummer,SG6,RFF,,,,,,Kann, - 89,Faxnummer,SG6,RFF,1153,,Z25,,Faxnummer,X, - 90,Faxnummer,SG6,RFF,1154,,,,Faxnummer,X [940],[940] Format: Die Zeichenkette muss mit dem Zeichen + beginnen und danach dürfen nur noch Ziffern folgen - 91,Erreichbarkeit an Werktagen,SG12,,,,,,,Muss, - 92,Erreichbarkeit an Werktagen,SG12,CCI,,,,,,Muss, - 93,Erreichbarkeit an Werktagen,SG12,CCI,7059,,Z40,,Erreichbarkeit desUnternehmens,X, - 94,Erreichbarkeit,SG12,DTM,,,,,,Muss, - 95,Erreichbarkeit,SG12,DTM,2005,,Z36,,Verfügbarkeit Montag,X [1P1..1], - 96,Erreichbarkeit,SG12,DTM,2005,,Z37,,Verfügbarkeit Dienstag,X [1P1..1], - 97,Erreichbarkeit,SG12,DTM,2005,,Z38,,Verfügbarkeit Mittwoch,X [1P1..1], - 98,Erreichbarkeit,SG12,DTM,2005,,Z39,,VerfügbarkeitDonnerstag,X [1P1..1], - 99,Erreichbarkeit,SG12,DTM,2005,,Z40,,Verfügbarkeit Freitag,X [1P1..1], - 100,Erreichbarkeit,SG12,DTM,2005,,Z41,,Mittagspause (=Ausschluss derVerfügbarkeit),X [1P0..1], - 101,Erreichbarkeit,SG12,DTM,2380,,,,"Datum oder Uhrzeit oderZeitspanne, Wert",X [503],[503] Hinweis: Angabe erfolgt in gesetzlicher deutscher Zeit - 102,Erreichbarkeit,SG12,DTM,2379,,501,,HHMMHHMM,X, - 103,Name und Anschrift Ansprechpartner Übertragungsweg / Datenaustausch,SG4,,,,,,,Muss [10],[10] Wenn BGM DE1373 = 11 (Dokument nicht verfügbar) nicht vorhanden - 104,Name und Anschrift Ansprechpartner Übertragungsweg / Datenaustausch,SG4,NAD,,,,,,Muss, - 105,Name und Anschrift Ansprechpartner Übertragungsweg / Datenaustausch,SG4,NAD,3035,,Z10,,Ansprechpartner,X, - 106,Name und Anschrift Ansprechpartner Übertragungsweg / Datenaustausch,SG4,NAD,3036,,,,Name,X [500],[500] Hinweis: Es kann der Firmenname eines Dienstleisters oder die identische Firmenbezeichnung aus SG4 NAD+SU / DDM / DEB / Z31 / Z34 / Z35 / Z36 eingetragen werden. - 107,Name und Anschrift Ansprechpartner Übertragungsweg / Datenaustausch,SG4,NAD,3045,,Z02,,Struktur derFirmenbezeichnung,X, - 108,Name und Anschrift Ansprechpartner Übertragungsweg / Datenaustausch,SG4,NAD,3042,,,,Straße und Hausnummer oderPostfach,X, - 109,Name und Anschrift Ansprechpartner Übertragungsweg / Datenaustausch,SG4,NAD,3164,,,,Ort,X, - 110,Name und Anschrift Ansprechpartner Übertragungsweg / Datenaustausch,SG4,NAD,3251,,,,Postleitzahl,M [2]S [3],"[2] Wenn der Code im DE3207 in der ""EDI@Energy Codeliste der europäischen Ländercodes"" in der Spalte ""PLZ vorhanden"" ein ""X"" enthält - [3] wenn vorhanden" - 111,Name und Anschrift Ansprechpartner Übertragungsweg / Datenaustausch,SG4,NAD,3207,,,,"Ländername, Code",X, - 112,Ansprechpartner,SG7,,,,,,,Muss, - 113,Ansprechpartner,SG7,CTA,,,,,,Muss, - 114,Ansprechpartner,SG7,CTA,3139,,IC,,Informationskontakt,X, - 115,Ansprechpartner,SG7,CTA,3412,,,,Name der organisatorischenEinheit,X [501],"[501] Hinweis: Es darf kein Name einer natürlichen Person übermittelt werden, stattdessen ist die organisatorische Einheit im Unternehmen zu nennen." - 116,Kommunikationsverbindung,SG7,COM,,,,,,Muss, - 117,Kommunikationsverbindung,SG7,COM,3148,,,,Nummer / Adresse,X (([939][6])∨ ([940][8]))∧ [502],"[6] wenn im DE3155 im demselben COM der Code EM vorhanden ist - [8] wenn im DE3155 im demselben COM der Code TE / FX vorhanden ist" - 118,Kommunikationsverbindung,SG7,COM,3155,,EM,,Elektronische Post,X [1P1..1], - 119,Kommunikationsverbindung,SG7,COM,3155,,TE,,Telefon,X [1P1..1], - 120,Kommunikationsverbindung,SG7,COM,3155,,FX,,Telefax,X [1P0..1], - 121,Name und Anschrift Ansprechpartner Rahmenverträge,SG4,,,,,,,Muss [10] ∧[35],"[10] Wenn BGM DE1373 = 11 (Dokument nicht verfügbar) nicht vorhanden - [35] Wenn MP-ID in SG2 NAD+MR (Nachrichtenempfänger) in der Rolle ÜNB - [36] Wenn MP-ID in SG2 NAD+MR (Nachrichtenempfänger) in der Rolle BKV" - 122,Name und Anschrift Ansprechpartner Rahmenverträge,SG4,NAD,,,,,,Muss, - 123,Name und Anschrift Ansprechpartner Rahmenverträge,SG4,NAD,3035,,Z11,,AnsprechpartnerRahmenverträge,X, - 124,Name und Anschrift Ansprechpartner Rahmenverträge,SG4,NAD,3036,,,,Name,X [500],[500] Hinweis: Es kann der Firmenname eines Dienstleisters oder die identische Firmenbezeichnung aus SG4 NAD+SU / DDM / DEB / Z31 / Z34 / Z35 / Z36 eingetragen werden. - 125,Name und Anschrift Ansprechpartner Rahmenverträge,SG4,NAD,3045,,Z02,,Struktur derFirmenbezeichnung,X, - 126,Name und Anschrift Ansprechpartner Rahmenverträge,SG4,NAD,3042,,,,Straße und Hausnummer oder,X, - 127,Name und Anschrift Ansprechpartner Rahmenverträge,SG4,NAD,3164,,,,Ort,X, - 128,Name und Anschrift Ansprechpartner Rahmenverträge,SG4,NAD,3251,,,,Postleitzahl,M [2]S [3],"[2] Wenn der Code im DE3207 in der ""EDI@Energy Codeliste der europäischen Ländercodes"" in der Spalte ""PLZ vorhanden"" ein ""X"" enthält - [3] wenn vorhanden" - 129,Name und Anschrift Ansprechpartner Rahmenverträge,SG4,NAD,3207,,,,"Ländername, Code",X, - 130,Ansprechpartner,SG7,,,,,,,Muss, - 131,Ansprechpartner,SG7,CTA,,,,,,Muss, - 132,Ansprechpartner,SG7,CTA,3139,,IC,,Informationskontakt,X, - 133,Ansprechpartner,SG7,CTA,3412,,,,Name der organisatorischenEinheit,X [501],"[501] Hinweis: Es darf kein Name einer natürlichen Person übermittelt werden, stattdessen ist die organisatorische Einheit im Unternehmen zu nennen." - 134,Kommunikationsverbindung,SG7,COM,,,,,,Muss, - 135,Kommunikationsverbindung,SG7,COM,3148,,,,Nummer / Adresse,X (([939][6])∨ ([940][8]))∧ [502],"[6] wenn im DE3155 im demselben COM der Code EM vorhanden ist - [8] wenn im DE3155 im demselben COM der Code TE / FX vorhanden ist - [502] Hinweis: Es darf nur eine Information im DE3148 übermittelt werden - [939] Format: Die Zeichenkette muss die Zeichen @ und . enthalten - [940] Format: Die Zeichenkette muss mit dem Zeichen + beginnen" - 136,Kommunikationsverbindung,SG7,COM,3155,,EM,,Elektronische Post,X [1P1..1], - 137,Kommunikationsverbindung,SG7,COM,3155,,TE,,Telefon,X [1P1..1], - 138,Kommunikationsverbindung,SG7,COM,3155,,FX,,Telefax,X [1P0..1], - 139,Name und Anschrift Ansprechpartner Stammdatenprozesse,SG4,,,,,,,,"[10] Wenn BGM DE1373 = 11 (Dokument nicht verfügbar) nicht vorhanden - [17] Wenn MP-ID in SG2 NAD+MR (Nachrichtenempfänger) in der Rolle LF/NB/MSB" - 140,Name und Anschrift Ansprechpartner Stammdatenprozesse,SG4,NAD,,,,,,, - 141,Name und Anschrift Ansprechpartner Stammdatenprozesse,SG4,NAD,3035,,Z14,,AnsprechpartnerStammdatenprozesse,, - 142,Name und Anschrift Ansprechpartner Stammdatenprozesse,SG4,NAD,3036,,,,Name,,[500] Hinweis: Es kann der Firmenname eines Dienstleisters oder die identische Firmenbezeichnung aus SG4 NAD+SU / DDM / DEB / Z31 / Z34 / Z35 / Z36 eingetragen werden. - 143,Name und Anschrift Ansprechpartner Stammdatenprozesse,SG4,NAD,3045,,Z02,,Struktur derFirmenbezeichnung,, - 144,Name und Anschrift Ansprechpartner Stammdatenprozesse,SG4,NAD,3042,,,,Straße und Hausnummer oderPostfach,, - 145,Name und Anschrift Ansprechpartner Stammdatenprozesse,SG4,NAD,3164,,,,Ort,, - 146,Name und Anschrift Ansprechpartner Stammdatenprozesse,SG4,NAD,3251,,,,Postleitzahl,,"[2] Wenn der Code im DE3207 in der ""EDI@Energy Codeliste der europäischen Ländercodes"" in der Spalte ""PLZ vorhanden"" ein ""X"" enthält - [3] wenn vorhanden" - 147,Name und Anschrift Ansprechpartner Stammdatenprozesse,SG4,NAD,3207,,,,"Ländername, Code",, - 148,Ansprechpartner,SG7,,,,,,,, - 149,Ansprechpartner,SG7,CTA,,,,,,, - 150,Ansprechpartner,SG7,CTA,3139,,IC,,Informationskontakt,, - 151,Ansprechpartner,SG7,CTA,3412,,,,Name der organisatorischen,,[501] Hinweis: Es darf - 152,Kommunikationsverbindung,SG7,COM,,,,,,, - 153,Kommunikationsverbindung,SG7,COM,3148,,,,Nummer / Adresse,,"[6] wenn im DE3155 im demselben COM der Code EM vorhanden ist - [8] wenn im DE3155 im demselben COM der Code TE / FX vorhanden ist - [502] Hinweis: Es darf nur eine Information im DE3148 übermittelt werden - [939] Format: Die Zeichenkette muss die Zeichen @ und . enthalten - [940] Format: Die Zeichenkette muss mit dem Zeichen + beginnen und danach dürfen nur noch Ziffern folgen" - 154,Kommunikationsverbindung,SG7,COM,3155,,EM,,Elektronische Post,, - 155,Kommunikationsverbindung,SG7,COM,3155,,TE,,Telefon,, - 156,Kommunikationsverbindung,SG7,COM,3155,,FX,,Telefax,, - 157,Name und Anschrift Ansprechpartner MMMA- Prozesse,SG4,,,,,,,,"[10] Wenn BGM DE1373 = 11 (Dokument nicht verfügbar) nicht vorhanden - [25] Wenn MP-ID in SG2 NAD+MR (Nachrichtenempfänger) in der Rolle NB" - 158,Name und Anschrift Ansprechpartner MMMA- Prozesse,SG4,NAD,,,,,,, - 159,Name und Anschrift Ansprechpartner MMMA- Prozesse,SG4,NAD,3035,,Z18,,AnsprechpartnerMMMA-Prozesse,, - 160,Name und Anschrift Ansprechpartner MMMA- Prozesse,SG4,NAD,3036,,,,Name,,[500] Hinweis: Es kann der Firmenname eines Dienstleisters oder die identische Firmenbezeichnung aus SG4 NAD+SU / DDM / DEB / Z31 / Z34 / Z35 / Z36 eingetragen werden. - 161,Name und Anschrift Ansprechpartner MMMA- Prozesse,SG4,NAD,3045,,Z02,,Struktur derFirmenbezeichnung,, - 162,Name und Anschrift Ansprechpartner MMMA- Prozesse,SG4,NAD,3042,,,,Straße und Hausnummer oderPostfach,, - 163,Name und Anschrift Ansprechpartner MMMA- Prozesse,SG4,NAD,3164,,,,Ort,, - 164,Name und Anschrift Ansprechpartner MMMA- Prozesse,SG4,NAD,3251,,,,Postleitzahl,,"[2] Wenn der Code im DE3207 in der ""EDI@Energy Codeliste der europäischen Ländercodes"" in der Spalte ""PLZ vorhanden"" ein ""X"" enthält - [3] wenn vorhanden" - 165,Name und Anschrift Ansprechpartner MMMA- Prozesse,SG4,NAD,3207,,,,"Ländername, Code",, - 166,Ansprechpartner,SG7,,,,,,,, - 167,Ansprechpartner,SG7,CTA,,,,,,, - 168,Ansprechpartner,SG7,CTA,3139,,IC,,Informationskontakt,, - 169,Ansprechpartner,SG7,CTA,3412,,,,Name der organisatorischenEinheit,,"[501] Hinweis: Es darf kein Name einer natürlichen Person übermittelt werden, stattdessen ist die organisatorische Einheit im Unternehmen zu nennen." - 170,Kommunikationsverbindung,SG7,COM,,,,,,, - 171,Kommunikationsverbindung,SG7,COM,3148,,,,Nummer / Adresse,,"[6] wenn im DE3155 im demselben COM der Code EM vorhanden ist - [8] wenn im DE3155 im demselben COM der Code TE / FX vorhanden" - 172,Kommunikationsverbindung,SG7,COM,3155,,EM,,Elektronische Post,, - 173,Kommunikationsverbindung,SG7,COM,3155,,TE,,Telefon,, - 174,Kommunikationsverbindung,SG7,COM,3155,,FX,,Telefax,, - 175,Name und Anschrift Bewegungsdaten,SG4,,,,,,,,"[10] Wenn BGM DE1373 = 11 (Dokument nicht verfügbar) nicht vorhanden - [17] Wenn MP-ID in SG2 NAD+MR (Nachrichtenempfänger) in der Rolle LF/NB/MSB" - 176,Name und Anschrift Bewegungsdaten,SG4,NAD,,,,,,, - 177,Name und Anschrift Bewegungsdaten,SG4,NAD,3035,,Z19,,AnsprechpartnerBewegungsdaten,, - 178,Name und Anschrift Bewegungsdaten,SG4,NAD,3036,,,,Name,,[500] Hinweis: Es kann der Firmenname eines Dienstleisters oder die identische Firmenbezeichnung aus SG4 NAD+SU / DDM / DEB / Z31 / Z34 / Z35 / Z36 eingetragen werden. - 179,Name und Anschrift Bewegungsdaten,SG4,NAD,3045,,Z02,,Struktur derFirmenbezeichnung,, - 180,Name und Anschrift Bewegungsdaten,SG4,NAD,3042,,,,Straße und Hausnummer oderPostfach,, - 181,Name und Anschrift Bewegungsdaten,SG4,NAD,3164,,,,Ort,, - 182,Name und Anschrift Bewegungsdaten,SG4,NAD,3251,,,,Postleitzahl,,[2] Wenn der Code im DE3207 in der - 183,Name und Anschrift Bewegungsdaten,SG4,NAD,3207,,,,"Ländername, Code",, - 184,Ansprechpartner,SG7,,,,,,,, - 185,Ansprechpartner,SG7,CTA,,,,,,, - 186,Ansprechpartner,SG7,CTA,3139,,IC,,Informationskontakt,, - 187,Ansprechpartner,SG7,CTA,3412,,,,Name der organisatorischenEinheit,,"[501] Hinweis: Es darf kein Name einer natürlichen Person übermittelt werden, stattdessen ist die organisatorische Einheit im Unternehmen zu nennen." - 188,Kommunikationsverbindung,SG7,COM,,,,,,, - 189,Kommunikationsverbindung,SG7,COM,3148,,,,Nummer / Adresse,,"[6] wenn im DE3155 im demselben COM der Code EM vorhanden ist - [8] wenn im DE3155 im demselben COM der Code TE / FX vorhanden ist - [502] Hinweis: Es darf nur eine Information im DE3148 übermittelt werden - [939] Format: Die Zeichenkette muss die Zeichen @ und . enthalten - [940] Format: Die Zeichenkette muss mit dem Zeichen + beginnen und danach dürfen nur noch Ziffern folgen" - 190,Kommunikationsverbindung,SG7,COM,3155,,EM,,Elektronische Post,, - 191,Kommunikationsverbindung,SG7,COM,3155,,TE,,Telefon,, - 192,Name und Anschrift Ansprechpartner Prozesse zur Unterbrechung und Wiederherstellung der Anschlussnutzung,SG4,,,,,,,,"[10] Wenn BGM DE1373 = 11 (Dokument nicht verfügbar) nicht vorhanden - [25] Wenn MP-ID in SG2 NAD+MR (Nachrichtenempfänger) in der Rolle NB" - 193,Name und Anschrift Ansprechpartner Prozesse zur Unterbrechung und Wiederherstellung der Anschlussnutzung,SG4,NAD,,,,,,, - 194,Name und Anschrift Ansprechpartner Prozesse zur Unterbrechung und Wiederherstellung der Anschlussnutzung,SG4,NAD,3035,,Z20,,AnsprechpartnerSperr-/Entsperrprozesse,, - 195,Name und Anschrift Ansprechpartner Prozesse zur Unterbrechung und Wiederherstellung der Anschlussnutzung,SG4,NAD,3036,,,,Name,,[500] Hinweis: Es kann der Firmenname eines Dienstleisters oder die identische Firmenbezeichnung aus SG4 NAD+SU / DDM / DEB / Z31 / Z34 / Z35 / Z36 eingetragen werden. - 196,Name und Anschrift Ansprechpartner Prozesse zur Unterbrechung und Wiederherstellung der Anschlussnutzung,SG4,NAD,3045,,Z02,,Struktur derFirmenbezeichnung,, - 197,Name und Anschrift Ansprechpartner Prozesse zur Unterbrechung und Wiederherstellung der Anschlussnutzung,SG4,NAD,3042,,,,Straße und Hausnummer oderPostfach,, - 198,Name und Anschrift Ansprechpartner Prozesse zur Unterbrechung und Wiederherstellung der Anschlussnutzung,SG4,NAD,3164,,,,Ort,, - 199,Name und Anschrift Ansprechpartner Prozesse zur Unterbrechung und Wiederherstellung der Anschlussnutzung,SG4,NAD,3251,,,,Postleitzahl,,"[2] Wenn der Code im DE3207 in der ""EDI@Energy Codeliste der europäischen Ländercodes"" in der Spalte ""PLZ vorhanden"" ein ""X"" enthält - [3] wenn vorhanden" - 200,Name und Anschrift Ansprechpartner Prozesse zur Unterbrechung und Wiederherstellung der Anschlussnutzung,SG4,NAD,3207,,,,"Ländername, Code",, - 201,Ansprechpartner,SG7,,,,,,,, - 202,Ansprechpartner,SG7,CTA,,,,,,, - 203,Ansprechpartner,SG7,CTA,3139,,IC,,Informationskontakt,, - 204,Ansprechpartner,SG7,CTA,3412,,,,Name der organisatorischenEinheit,,[501] Hinweis: Es darf kein Name einer natürlichen Person - 205,Kommunikationsverbindung,SG7,COM,,,,,,, - 206,Kommunikationsverbindung,SG7,COM,3148,,,,Nummer / Adresse,,"[6] wenn im DE3155 im demselben COM der Code EM vorhanden ist - [8] wenn im DE3155 im demselben COM der Code TE / FX vorhanden ist - [502] Hinweis: Es darf nur eine Information im DE3148 übermittelt werden - [939] Format: Die Zeichenkette muss die Zeichen @ und . enthalten - [940] Format: Die Zeichenkette muss mit dem Zeichen + beginnen und danach dürfen nur noch Ziffern folgen" - 207,Kommunikationsverbindung,SG7,COM,3155,,EM,,Elektronische Post,, - 208,Kommunikationsverbindung,SG7,COM,3155,,TE,,Telefon,, - 209,Kommunikationsverbindung,SG7,COM,3155,,FX,,Telefax,, - 210,Name und Anschrift Ansprechpartner Bilanzierungsprozesse / Bilanzkreismanagement,SG4,,,,,,,Muss [10],"[10] Wenn BGM DE1373 = 11 (Dokument nicht verfügbar) nicht vorhanden - [26] Wenn MP-ID in SG2 NAD+MR (Nachrichtenempfänger) in der Rolle NB/LF/BKV/ BIKO" - 211,Name und Anschrift Ansprechpartner Bilanzierungsprozesse / Bilanzkreismanagement,SG4,NAD,,,,,,Muss, - 212,Name und Anschrift Ansprechpartner Bilanzierungsprozesse / Bilanzkreismanagement,SG4,NAD,3035,,Z21,,AnsprechpartnerBilanzierungsprozesse /Bilanzkreismanagement,X, - 213,Name und Anschrift Ansprechpartner Bilanzierungsprozesse / Bilanzkreismanagement,SG4,NAD,3036,,,,Name,X [500],[500] Hinweis: Es kann der Firmenname eines Dienstleisters oder die identische Firmenbezeichnung aus SG4 NAD+SU / DDM / DEB / Z31 / Z34 / Z35 / Z36 eingetragen werden. - 214,Name und Anschrift Ansprechpartner Bilanzierungsprozesse / Bilanzkreismanagement,SG4,NAD,3045,,Z02,,Struktur derFirmenbezeichnung,X, - 215,Name und Anschrift Ansprechpartner Bilanzierungsprozesse / Bilanzkreismanagement,SG4,NAD,3042,,,,Straße und Hausnummer oderPostfach,X, - 216,Name und Anschrift Ansprechpartner Bilanzierungsprozesse / Bilanzkreismanagement,SG4,NAD,3164,,,,Ort,X, - 217,Name und Anschrift Ansprechpartner Bilanzierungsprozesse / Bilanzkreismanagement,SG4,NAD,3251,,,,Postleitzahl,M [2]S [3],"[2] Wenn der Code im DE3207 in der ""EDI@Energy Codeliste der europäischen Ländercodes"" in der Spalte ""PLZ vorhanden"" ein ""X"" enthält - [3] wenn vorhanden" - 218,Name und Anschrift Ansprechpartner Bilanzierungsprozesse / Bilanzkreismanagement,SG4,NAD,3207,,,,"Ländername, Code",X, - 219,Ansprechpartner,SG7,,,,,,,Muss, - 220,Ansprechpartner,SG7,CTA,,,,,,Muss, - 221,Ansprechpartner,SG7,CTA,3139,,IC,,Informationskontakt,X, - 222,Ansprechpartner,SG7,CTA,3412,,,,Name der organisatorischenEinheit,X [501],"[501] Hinweis: Es darf kein Name einer natürlichen Person übermittelt werden, stattdessen ist die organisatorische Einheit im Unternehmen zu nennen." - 223,Kommunikationsverbindung,SG7,COM,,,,,,Muss, - 224,Kommunikationsverbindung,SG7,COM,3148,,,,Nummer / Adresse,X (([939][6])∨ ([940][8]))∧ [502],"[6] wenn im DE3155 im demselben COM der Code EM vorhanden ist - [8] wenn im DE3155 im demselben COM der" - 225,Kommunikationsverbindung,SG7,COM,3155,,EM,,Elektronische Post,X [1P1..1], - 226,Kommunikationsverbindung,SG7,COM,3155,,TE,,Telefon,X [1P1..1], - 227,Kommunikationsverbindung,SG7,COM,3155,,FX,,Telefax,X [1P0..1], - 228,Nachrichten-Endesegment,,UNT,,,,,,Muss, - 229,Nachrichten-Endesegment,,UNT,0074,,,,Anzahl der Segmente in einerNachricht,X, - 230,Nachrichten-Endesegment,,UNT,0062,,,,Nachrichten-Referenznummer,X, - - ''', - '37004.csv': ''' - ,Segmentname,Segmentgruppe,Segment,Datenelement,Segment ID,Code,Qualifier,Beschreibung,Bedingungsausdruck,Bedingung - 0,Nachrichten-Kopfsegment,,UNH,,,,,,Muss, - 1,Nachrichten-Kopfsegment,,UNH,0062,,,,Nachrichten-Referenznummer,X, - 2,Nachrichten-Kopfsegment,,UNH,0065,,PARTIN,,Partnerstammdaten,X, - 3,Nachrichten-Kopfsegment,,UNH,0052,,D,,Entwurfs-Version,X, - 4,Nachrichten-Kopfsegment,,UNH,0054,,20B,,Ausgabe 2020 - B,X, - 5,Nachrichten-Kopfsegment,,UNH,0051,,UN,,UN/CEFACT,X, - 6,Nachrichten-Kopfsegment,,UNH,0057,,1.0c,,Versionsnummer derzugrundeliegendenBDEW-Nachrichtenbeschreibung,X, - 7,Beginn der Nachricht,,BGM,,,,,,Muss, - 8,Beginn der Nachricht,,BGM,1001,,10,,Partnerstammdaten,X, - 9,Beginn der Nachricht,,BGM,1004,,,,Dokumentennummer,X, - 10,Beginn der Nachricht,,BGM,1373,,11,,Dokument nichtverfügbar,S [9],[9] Wenn die Kommunikationsdaten vom Absender nicht mehr aktiv sind. - 11,Nachrichtendatum,,DTM,,,,,,Muss, - 12,Nachrichtendatum,,DTM,2005,,137,,Dokumenten-/Nachrichtendatum/-zeit,X, - 13,Nachrichtendatum,,DTM,2380,,,,"Datum oder Uhrzeit oderZeitspanne, Wert",X [931][494],"[494] Das hier genannte Datum muss der Zeitpunkt sein, zu dem das Dokument erstellt wurde, oder ein Zeitpunkt, der davor liegt. - [931] Format: ZZZ = +00" - 14,Nachrichtendatum,,DTM,2379,,303,,CCYYMMDDHHMMZZZ,X, - 15,Prüfidentifikator,SG1,,,,,,,Muss, - 16,Prüfidentifikator,SG1,RFF,,,,,,Muss, - 17,Prüfidentifikator,SG1,RFF,1153,,Z13,,Prüfidentifikator,X, - 18,Prüfidentifikator,SG1,RFF,1154,,37003,,ÜbermittlungKommunikationsdatendes BKV,, - 19,Prüfidentifikator,SG1,RFF,1154,,37004,,ÜbermittlungKommunikationsdatendes BIKO,X, - 20,Prüfidentifikator,SG1,RFF,1154,,37005,,ÜbermittlungKommunikationsdatendes ÜNB,, - 21,Versionsnummer,SG1,,,,,,,Muss, - 22,Versionsnummer,SG1,RFF,,,,,,Muss, - 23,Versionsnummer,SG1,RFF,1153,,AGK,,Anwendungsreferenznummer,X, - 24,Versionsnummer,SG1,RFF,1056,,,,Versionsnummer,X [908][505],"[505] Wenn eine Vorgängerversion (RFF+ACW) angegeben ist, so muss der Wert in diesem DE1056 mindestens um 1 höher sein, als der Wert aus DE1056 der Vorgängerversion (RFF+ACW). - [908] Format: Mögliche Werte: 1 bis n" - 25,Gültig Ab,SG1,DTM,,,,,,Soll [4],[4] Wenn Vorgängerversion vorhanden - 26,Gültig Ab,SG1,DTM,2005,,157,,"Gültigkeit, Beginndatum",X, - 27,Gültig Ab,SG1,DTM,2380,,,,"Datum oder Uhrzeit oderZeitspanne, Wert",X [UB1], - 28,Gültig Ab,SG1,DTM,2379,,303,,CCYYMMDDHHMMZZZ,X, - 29,Vorgängerversion,SG1,,,,,,,Soll [4],[4] Wenn Vorgängerversion vorhanden - 30,Vorgängerversion,SG1,RFF,,,,,,Muss, - 31,Vorgängerversion,SG1,RFF,1153,,ACW,,Referenznummer einervorangegangenenNachricht,X, - 32,Vorgängerversion,SG1,RFF,1056,,,,Versionsnummer,X [908],[908] Format: Mögliche Werte: 1 bis n - 33,MP-ID Absender,SG2,,,,,,,Muss, - 34,MP-ID Absender,SG2,NAD,,,,,,Muss, - 35,MP-ID Absender,SG2,NAD,3035,,MS,,Dokumenten-/Nachrichtenausstellerbzw. -absender,X, - 36,MP-ID Absender,SG2,NAD,3039,,,,MP-ID,X [1],[1] Nur MP-ID aus Sparte Strom - 37,MP-ID Absender,SG2,NAD,3055,,9,,GS1,X, - 38,MP-ID Absender,SG2,NAD,3055,,293,,"DE, BDEW",X, - 39,Ansprechpartner,SG3,,,,,,,Kann, - 40,Ansprechpartner,SG3,CTA,,,,,,Muss, - 41,Ansprechpartner,SG3,CTA,3139,,IC,,Informationskontakt,X, - 42,Ansprechpartner,SG3,CTA,3412,,,,Name vom Ansprechpartner,X, - 43,Kommunikationsverbindung,SG3,COM,,,,,,Muss, - 44,Kommunikationsverbindung,SG3,COM,3148,,,,Nummer / Adresse,X (([939][6])∨ ([940][7]))∧ [502],"[6] wenn im DE3155 im demselben COM der Code EM vorhanden ist - [7] wenn im DE3155 im demselben COM der Code TE / FX / AJ / AL vorhanden ist - [502] Hinweis: Es darf nur eine Information im DE3148 übermittelt werden - [939] Format: Die Zeichenkette muss die Zeichen @ und . enthalten - [940] Format: Die Zeichenkette muss mit dem Zeichen + beginnen und danach dürfen nur noch Ziffern folgen" - 45,Kommunikationsverbindung,SG3,COM,3155,,EM,,Elektronische Post,X [1P0..1], - 46,Kommunikationsverbindung,SG3,COM,3155,,FX,,Telefax,X [1P0..1], - 47,Kommunikationsverbindung,SG3,COM,3155,,TE,,Telefon,X [1P0..1], - 48,Kommunikationsverbindung,SG3,COM,3155,,AJ,,weiteres Telefon,X [1P0..1], - 49,Kommunikationsverbindung,SG3,COM,3155,,AL,,Handy,X [1P0..1], - 50,MP-ID Empfänger,SG2,,,,,,,Muss, - 51,MP-ID Empfänger,SG2,NAD,,,,,,Muss, - 52,MP-ID Empfänger,SG2,NAD,3035,,MR,,Nachrichtenempfänger,X, - 53,MP-ID Empfänger,SG2,NAD,3039,,,,MP-ID,X [1],[1] Nur MP-ID aus Sparte Strom - 54,MP-ID Empfänger,SG2,NAD,3055,,9,,GS1,X, - 55,MP-ID Empfänger,SG2,NAD,3055,,293,,"DE, BDEW",X, - 56,Abschnitts-Kontrollsegment,,UNS,,,,,,Muss, - 57,Abschnitts-Kontrollsegment,,UNS,0081,,D,,Trennung von Kopf- undPositionsteil,X, - 58,Name und Adresse des Unternehmens,SG4,,,,,,,Muss [10],[10] Wenn BGM DE1373 = 11 (Dokument nicht verfügbar) nicht vorhanden - 59,Name und Adresse des Unternehmens,SG4,NAD,,,,,,Muss, - 60,Name und Adresse des Unternehmens,SG4,NAD,3035,,Z31,,Übertragungsnetzbetreiber,, - 61,Name und Adresse des Unternehmens,SG4,NAD,3035,,Z34,,Bilanzkoordinator,X, - 62,Name und Adresse des Unternehmens,SG4,NAD,3035,,Z35,,Bilanzkreisverantwortlicher,, - 63,Name und Adresse des Unternehmens,SG4,NAD,3036,,,,Name,X [506],"[506] Hinweis: Das Datenelement ist so zu füllen, dass sein Inhalt den Vorgaben des USt.- Gesetzes genügt, so dass der Empfänger diese Daten in einer INVOIC nutzen kann." - 64,Name und Adresse des Unternehmens,SG4,NAD,3045,,Z02,,Struktur derFirmenbezeichnung,X, - 65,Name und Adresse des Unternehmens,SG4,NAD,3042,,,,Straße und Hausnummer oderPostfach,X [506],"[506] Hinweis: Das Datenelement ist so zu füllen, dass sein Inhalt den Vorgaben des USt.- Gesetzes genügt, so dass der Empfänger diese Daten in einer INVOIC nutzen kann." - 66,Name und Adresse des Unternehmens,SG4,NAD,3164,,,,Ort,X [506],"[506] Hinweis: Das Datenelement ist so zu füllen, dass sein Inhalt den Vorgaben des USt.- Gesetzes genügt, so dass der Empfänger diese Daten in einer INVOIC nutzen kann." - 67,Name und Adresse des Unternehmens,SG4,NAD,3251,,,,Postleitzahl,M [2] ∧[506]S [3] ∧ [506],"[2] Wenn der Code im DE3207 in der ""EDI@Energy Codeliste der europäischen" - 68,Name und Adresse des Unternehmens,SG4,NAD,3207,,,,"Ländername, Code",X [506],"[506] Hinweis: Das Datenelement ist so zu füllen, dass sein Inhalt den Vorgaben des USt.- Gesetzes genügt, so dass der Empfänger diese Daten in einer INVOIC nutzen kann." - 69,Bankverbindung,SG4,FII,,,,,,Muss, - 70,Bankverbindung,SG4,FII,3035,,BK,,Kreditinstitut,X, - 71,Bankverbindung,SG4,FII,3194,,IBAN,,,X, - 72,Bankverbindung,SG4,FII,3192,,,,Name des Kontoinhabers,X, - 73,Bankverbindung,SG4,FII,3192,,,,Name des Kontoinhabers,K, - 74,Bankverbindung,SG4,FII,3433,,BIC,,,X, - 75,Bankverbindung,SG4,FII,3432,,,,Name des Kredinstituts,X, - 76,Internetseite (URL),SG4,FTX,,,,,,Muss, - 77,Internetseite (URL),SG4,FTX,4451,,Z13,,Internetseite,X, - 78,Internetseite (URL),SG4,FTX,4440,,,,Internetseite,X, - 79,Gericht und Handelsregister-Nummer,SG4,FTX,,,,,,Soll [3],[3] wenn vorhanden - 80,Gericht und Handelsregister-Nummer,SG4,FTX,4451,,Z15,,Gericht undHandelsregister-Nummer,X, - 81,Gericht und Handelsregister-Nummer,SG4,FTX,4440,,,,Gericht,X, - 82,Gericht und Handelsregister-Nummer,SG4,FTX,4440,,,,Handelsregister-Nummer,X, - 83,"Steuernummer, Umsatzsteuernummer",SG6,,,,,,,Muss, - 84,"Steuernummer, Umsatzsteuernummer",SG6,RFF,,,,,,Muss, - 85,"Steuernummer, Umsatzsteuernummer",SG6,RFF,1153,,VA,,Umsatzsteuernummer,X [2P0..1] ⊻[3P1..1], - 86,"Steuernummer, Umsatzsteuernummer",SG6,RFF,1153,,FC,,Steuernummer,X [2P0..1], - 87,"Steuernummer, Umsatzsteuernummer",SG6,RFF,1154,,,,"Referenz, Identifikation",X, - 88,Faxnummer,SG6,RFF,,,,,,Kann, - 89,Faxnummer,SG6,RFF,1153,,Z25,,Faxnummer,X, - 90,Faxnummer,SG6,RFF,1154,,,,Faxnummer,X [940],[940] Format: Die Zeichenkette muss mit dem Zeichen + beginnen und danach dürfen nur noch Ziffern folgen - 91,Erreichbarkeit an Werktagen,SG12,,,,,,,Muss, - 92,Erreichbarkeit an Werktagen,SG12,CCI,,,,,,Muss, - 93,Erreichbarkeit an Werktagen,SG12,CCI,7059,,Z40,,Erreichbarkeit desUnternehmens,X, - 94,Erreichbarkeit,SG12,DTM,,,,,,Muss, - 95,Erreichbarkeit,SG12,DTM,2005,,Z36,,Verfügbarkeit Montag,X [1P1..1], - 96,Erreichbarkeit,SG12,DTM,2005,,Z37,,Verfügbarkeit Dienstag,X [1P1..1], - 97,Erreichbarkeit,SG12,DTM,2005,,Z38,,Verfügbarkeit Mittwoch,X [1P1..1], - 98,Erreichbarkeit,SG12,DTM,2005,,Z39,,VerfügbarkeitDonnerstag,X [1P1..1], - 99,Erreichbarkeit,SG12,DTM,2005,,Z40,,Verfügbarkeit Freitag,X [1P1..1], - 100,Erreichbarkeit,SG12,DTM,2005,,Z41,,Mittagspause (=Ausschluss derVerfügbarkeit),X [1P0..1], - 101,Erreichbarkeit,SG12,DTM,2380,,,,"Datum oder Uhrzeit oderZeitspanne, Wert",X [503],[503] Hinweis: Angabe erfolgt in gesetzlicher deutscher Zeit - 102,Erreichbarkeit,SG12,DTM,2379,,501,,HHMMHHMM,X, - 103,Name und Anschrift Ansprechpartner Übertragungsweg / Datenaustausch,SG4,,,,,,,Muss [10],[10] Wenn BGM DE1373 = 11 (Dokument nicht verfügbar) nicht vorhanden - 104,Name und Anschrift Ansprechpartner Übertragungsweg / Datenaustausch,SG4,NAD,,,,,,Muss, - 105,Name und Anschrift Ansprechpartner Übertragungsweg / Datenaustausch,SG4,NAD,3035,,Z10,,Ansprechpartner,X, - 106,Name und Anschrift Ansprechpartner Übertragungsweg / Datenaustausch,SG4,NAD,3036,,,,Name,X [500],[500] Hinweis: Es kann der Firmenname eines Dienstleisters oder die identische Firmenbezeichnung aus SG4 NAD+SU / DDM / DEB / Z31 / Z34 / Z35 / Z36 eingetragen werden. - 107,Name und Anschrift Ansprechpartner Übertragungsweg / Datenaustausch,SG4,NAD,3045,,Z02,,Struktur derFirmenbezeichnung,X, - 108,Name und Anschrift Ansprechpartner Übertragungsweg / Datenaustausch,SG4,NAD,3042,,,,Straße und Hausnummer oderPostfach,X, - 109,Name und Anschrift Ansprechpartner Übertragungsweg / Datenaustausch,SG4,NAD,3164,,,,Ort,X, - 110,Name und Anschrift Ansprechpartner Übertragungsweg / Datenaustausch,SG4,NAD,3251,,,,Postleitzahl,M [2]S [3],"[2] Wenn der Code im DE3207 in der ""EDI@Energy Codeliste der europäischen Ländercodes"" in der Spalte ""PLZ vorhanden"" ein ""X"" enthält - [3] wenn vorhanden" - 111,Name und Anschrift Ansprechpartner Übertragungsweg / Datenaustausch,SG4,NAD,3207,,,,"Ländername, Code",X, - 112,Ansprechpartner,SG7,,,,,,,Muss, - 113,Ansprechpartner,SG7,CTA,,,,,,Muss, - 114,Ansprechpartner,SG7,CTA,3139,,IC,,Informationskontakt,X, - 115,Ansprechpartner,SG7,CTA,3412,,,,Name der organisatorischenEinheit,X [501],"[501] Hinweis: Es darf kein Name einer natürlichen Person übermittelt werden, stattdessen ist die organisatorische Einheit im Unternehmen zu nennen." - 116,Kommunikationsverbindung,SG7,COM,,,,,,Muss, - 117,Kommunikationsverbindung,SG7,COM,3148,,,,Nummer / Adresse,X (([939][6])∨ ([940][8]))∧ [502],"[6] wenn im DE3155 im demselben COM der Code EM vorhanden ist - [8] wenn im DE3155 im demselben COM der Code TE / FX vorhanden ist" - 118,Kommunikationsverbindung,SG7,COM,3155,,EM,,Elektronische Post,X [1P1..1], - 119,Kommunikationsverbindung,SG7,COM,3155,,TE,,Telefon,X [1P1..1], - 120,Kommunikationsverbindung,SG7,COM,3155,,FX,,Telefax,X [1P0..1], - 121,Name und Anschrift Ansprechpartner Rahmenverträge,SG4,,,,,,,,"[10] Wenn BGM DE1373 = 11 (Dokument nicht verfügbar) nicht vorhanden - [35] Wenn MP-ID in SG2 NAD+MR (Nachrichtenempfänger) in der Rolle ÜNB - [36] Wenn MP-ID in SG2 NAD+MR (Nachrichtenempfänger) in der Rolle BKV" - 122,Name und Anschrift Ansprechpartner Rahmenverträge,SG4,NAD,,,,,,, - 123,Name und Anschrift Ansprechpartner Rahmenverträge,SG4,NAD,3035,,Z11,,AnsprechpartnerRahmenverträge,, - 124,Name und Anschrift Ansprechpartner Rahmenverträge,SG4,NAD,3036,,,,Name,,[500] Hinweis: Es kann der Firmenname eines Dienstleisters oder die identische Firmenbezeichnung aus SG4 NAD+SU / DDM / DEB / Z31 / Z34 / Z35 / Z36 eingetragen werden. - 125,Name und Anschrift Ansprechpartner Rahmenverträge,SG4,NAD,3045,,Z02,,Struktur derFirmenbezeichnung,, - 126,Name und Anschrift Ansprechpartner Rahmenverträge,SG4,NAD,3042,,,,Straße und Hausnummer oder,, - 127,Name und Anschrift Ansprechpartner Rahmenverträge,SG4,NAD,3164,,,,Ort,, - 128,Name und Anschrift Ansprechpartner Rahmenverträge,SG4,NAD,3251,,,,Postleitzahl,,"[2] Wenn der Code im DE3207 in der ""EDI@Energy Codeliste der europäischen Ländercodes"" in der Spalte ""PLZ vorhanden"" ein ""X"" enthält - [3] wenn vorhanden" - 129,Name und Anschrift Ansprechpartner Rahmenverträge,SG4,NAD,3207,,,,"Ländername, Code",, - 130,Ansprechpartner,SG7,,,,,,,, - 131,Ansprechpartner,SG7,CTA,,,,,,, - 132,Ansprechpartner,SG7,CTA,3139,,IC,,Informationskontakt,, - 133,Ansprechpartner,SG7,CTA,3412,,,,Name der organisatorischenEinheit,,"[501] Hinweis: Es darf kein Name einer natürlichen Person übermittelt werden, stattdessen ist die organisatorische Einheit im Unternehmen zu nennen." - 134,Kommunikationsverbindung,SG7,COM,,,,,,, - 135,Kommunikationsverbindung,SG7,COM,3148,,,,Nummer / Adresse,,"[6] wenn im DE3155 im demselben COM der Code EM vorhanden ist - [8] wenn im DE3155 im demselben COM der Code TE / FX vorhanden ist - [502] Hinweis: Es darf nur eine Information im DE3148 übermittelt werden - [939] Format: Die Zeichenkette muss die Zeichen @ und . enthalten - [940] Format: Die Zeichenkette muss mit dem Zeichen + beginnen" - 136,Kommunikationsverbindung,SG7,COM,3155,,EM,,Elektronische Post,, - 137,Kommunikationsverbindung,SG7,COM,3155,,TE,,Telefon,, - 138,Kommunikationsverbindung,SG7,COM,3155,,FX,,Telefax,, - 139,Name und Anschrift Ansprechpartner Stammdatenprozesse,SG4,,,,,,,,"[10] Wenn BGM DE1373 = 11 (Dokument nicht verfügbar) nicht vorhanden - [17] Wenn MP-ID in SG2 NAD+MR (Nachrichtenempfänger) in der Rolle LF/NB/MSB" - 140,Name und Anschrift Ansprechpartner Stammdatenprozesse,SG4,NAD,,,,,,, - 141,Name und Anschrift Ansprechpartner Stammdatenprozesse,SG4,NAD,3035,,Z14,,AnsprechpartnerStammdatenprozesse,, - 142,Name und Anschrift Ansprechpartner Stammdatenprozesse,SG4,NAD,3036,,,,Name,,[500] Hinweis: Es kann der Firmenname eines Dienstleisters oder die identische Firmenbezeichnung aus SG4 NAD+SU / DDM / DEB / Z31 / Z34 / Z35 / Z36 eingetragen werden. - 143,Name und Anschrift Ansprechpartner Stammdatenprozesse,SG4,NAD,3045,,Z02,,Struktur derFirmenbezeichnung,, - 144,Name und Anschrift Ansprechpartner Stammdatenprozesse,SG4,NAD,3042,,,,Straße und Hausnummer oderPostfach,, - 145,Name und Anschrift Ansprechpartner Stammdatenprozesse,SG4,NAD,3164,,,,Ort,, - 146,Name und Anschrift Ansprechpartner Stammdatenprozesse,SG4,NAD,3251,,,,Postleitzahl,,"[2] Wenn der Code im DE3207 in der ""EDI@Energy Codeliste der europäischen Ländercodes"" in der Spalte ""PLZ vorhanden"" ein ""X"" enthält - [3] wenn vorhanden" - 147,Name und Anschrift Ansprechpartner Stammdatenprozesse,SG4,NAD,3207,,,,"Ländername, Code",, - 148,Ansprechpartner,SG7,,,,,,,, - 149,Ansprechpartner,SG7,CTA,,,,,,, - 150,Ansprechpartner,SG7,CTA,3139,,IC,,Informationskontakt,, - 151,Ansprechpartner,SG7,CTA,3412,,,,Name der organisatorischen,,[501] Hinweis: Es darf - 152,Kommunikationsverbindung,SG7,COM,,,,,,, - 153,Kommunikationsverbindung,SG7,COM,3148,,,,Nummer / Adresse,,"[6] wenn im DE3155 im demselben COM der Code EM vorhanden ist - [8] wenn im DE3155 im demselben COM der Code TE / FX vorhanden ist - [502] Hinweis: Es darf nur eine Information im DE3148 übermittelt werden - [939] Format: Die Zeichenkette muss die Zeichen @ und . enthalten - [940] Format: Die Zeichenkette muss mit dem Zeichen + beginnen und danach dürfen nur noch Ziffern folgen" - 154,Kommunikationsverbindung,SG7,COM,3155,,EM,,Elektronische Post,, - 155,Kommunikationsverbindung,SG7,COM,3155,,TE,,Telefon,, - 156,Kommunikationsverbindung,SG7,COM,3155,,FX,,Telefax,, - 157,Name und Anschrift Ansprechpartner MMMA- Prozesse,SG4,,,,,,,,"[10] Wenn BGM DE1373 = 11 (Dokument nicht verfügbar) nicht vorhanden - [25] Wenn MP-ID in SG2 NAD+MR (Nachrichtenempfänger) in der Rolle NB" - 158,Name und Anschrift Ansprechpartner MMMA- Prozesse,SG4,NAD,,,,,,, - 159,Name und Anschrift Ansprechpartner MMMA- Prozesse,SG4,NAD,3035,,Z18,,AnsprechpartnerMMMA-Prozesse,, - 160,Name und Anschrift Ansprechpartner MMMA- Prozesse,SG4,NAD,3036,,,,Name,,[500] Hinweis: Es kann der Firmenname eines Dienstleisters oder die identische Firmenbezeichnung aus SG4 NAD+SU / DDM / DEB / Z31 / Z34 / Z35 / Z36 eingetragen werden. - 161,Name und Anschrift Ansprechpartner MMMA- Prozesse,SG4,NAD,3045,,Z02,,Struktur derFirmenbezeichnung,, - 162,Name und Anschrift Ansprechpartner MMMA- Prozesse,SG4,NAD,3042,,,,Straße und Hausnummer oderPostfach,, - 163,Name und Anschrift Ansprechpartner MMMA- Prozesse,SG4,NAD,3164,,,,Ort,, - 164,Name und Anschrift Ansprechpartner MMMA- Prozesse,SG4,NAD,3251,,,,Postleitzahl,,"[2] Wenn der Code im DE3207 in der ""EDI@Energy Codeliste der europäischen Ländercodes"" in der Spalte ""PLZ vorhanden"" ein ""X"" enthält - [3] wenn vorhanden" - 165,Name und Anschrift Ansprechpartner MMMA- Prozesse,SG4,NAD,3207,,,,"Ländername, Code",, - 166,Ansprechpartner,SG7,,,,,,,, - 167,Ansprechpartner,SG7,CTA,,,,,,, - 168,Ansprechpartner,SG7,CTA,3139,,IC,,Informationskontakt,, - 169,Ansprechpartner,SG7,CTA,3412,,,,Name der organisatorischenEinheit,,"[501] Hinweis: Es darf kein Name einer natürlichen Person übermittelt werden, stattdessen ist die organisatorische Einheit im Unternehmen zu nennen." - 170,Kommunikationsverbindung,SG7,COM,,,,,,, - 171,Kommunikationsverbindung,SG7,COM,3148,,,,Nummer / Adresse,,"[6] wenn im DE3155 im demselben COM der Code EM vorhanden ist - [8] wenn im DE3155 im demselben COM der Code TE / FX vorhanden" - 172,Kommunikationsverbindung,SG7,COM,3155,,EM,,Elektronische Post,, - 173,Kommunikationsverbindung,SG7,COM,3155,,TE,,Telefon,, - 174,Kommunikationsverbindung,SG7,COM,3155,,FX,,Telefax,, - 175,Name und Anschrift Bewegungsdaten,SG4,,,,,,,,"[10] Wenn BGM DE1373 = 11 (Dokument nicht verfügbar) nicht vorhanden - [17] Wenn MP-ID in SG2 NAD+MR (Nachrichtenempfänger) in der Rolle LF/NB/MSB" - 176,Name und Anschrift Bewegungsdaten,SG4,NAD,,,,,,, - 177,Name und Anschrift Bewegungsdaten,SG4,NAD,3035,,Z19,,AnsprechpartnerBewegungsdaten,, - 178,Name und Anschrift Bewegungsdaten,SG4,NAD,3036,,,,Name,,[500] Hinweis: Es kann der Firmenname eines Dienstleisters oder die identische Firmenbezeichnung aus SG4 NAD+SU / DDM / DEB / Z31 / Z34 / Z35 / Z36 eingetragen werden. - 179,Name und Anschrift Bewegungsdaten,SG4,NAD,3045,,Z02,,Struktur derFirmenbezeichnung,, - 180,Name und Anschrift Bewegungsdaten,SG4,NAD,3042,,,,Straße und Hausnummer oderPostfach,, - 181,Name und Anschrift Bewegungsdaten,SG4,NAD,3164,,,,Ort,, - 182,Name und Anschrift Bewegungsdaten,SG4,NAD,3251,,,,Postleitzahl,,[2] Wenn der Code im DE3207 in der - 183,Name und Anschrift Bewegungsdaten,SG4,NAD,3207,,,,"Ländername, Code",, - 184,Ansprechpartner,SG7,,,,,,,, - 185,Ansprechpartner,SG7,CTA,,,,,,, - 186,Ansprechpartner,SG7,CTA,3139,,IC,,Informationskontakt,, - 187,Ansprechpartner,SG7,CTA,3412,,,,Name der organisatorischenEinheit,,"[501] Hinweis: Es darf kein Name einer natürlichen Person übermittelt werden, stattdessen ist die organisatorische Einheit im Unternehmen zu nennen." - 188,Kommunikationsverbindung,SG7,COM,,,,,,, - 189,Kommunikationsverbindung,SG7,COM,3148,,,,Nummer / Adresse,,"[6] wenn im DE3155 im demselben COM der Code EM vorhanden ist - [8] wenn im DE3155 im demselben COM der Code TE / FX vorhanden ist - [502] Hinweis: Es darf nur eine Information im DE3148 übermittelt werden - [939] Format: Die Zeichenkette muss die Zeichen @ und . enthalten - [940] Format: Die Zeichenkette muss mit dem Zeichen + beginnen und danach dürfen nur noch Ziffern folgen" - 190,Kommunikationsverbindung,SG7,COM,3155,,EM,,Elektronische Post,, - 191,Kommunikationsverbindung,SG7,COM,3155,,TE,,Telefon,, - 192,Name und Anschrift Ansprechpartner Prozesse zur Unterbrechung und Wiederherstellung der Anschlussnutzung,SG4,,,,,,,,"[10] Wenn BGM DE1373 = 11 (Dokument nicht verfügbar) nicht vorhanden - [25] Wenn MP-ID in SG2 NAD+MR (Nachrichtenempfänger) in der Rolle NB" - 193,Name und Anschrift Ansprechpartner Prozesse zur Unterbrechung und Wiederherstellung der Anschlussnutzung,SG4,NAD,,,,,,, - 194,Name und Anschrift Ansprechpartner Prozesse zur Unterbrechung und Wiederherstellung der Anschlussnutzung,SG4,NAD,3035,,Z20,,AnsprechpartnerSperr-/Entsperrprozesse,, - 195,Name und Anschrift Ansprechpartner Prozesse zur Unterbrechung und Wiederherstellung der Anschlussnutzung,SG4,NAD,3036,,,,Name,,[500] Hinweis: Es kann der Firmenname eines Dienstleisters oder die identische Firmenbezeichnung aus SG4 NAD+SU / DDM / DEB / Z31 / Z34 / Z35 / Z36 eingetragen werden. - 196,Name und Anschrift Ansprechpartner Prozesse zur Unterbrechung und Wiederherstellung der Anschlussnutzung,SG4,NAD,3045,,Z02,,Struktur derFirmenbezeichnung,, - 197,Name und Anschrift Ansprechpartner Prozesse zur Unterbrechung und Wiederherstellung der Anschlussnutzung,SG4,NAD,3042,,,,Straße und Hausnummer oderPostfach,, - 198,Name und Anschrift Ansprechpartner Prozesse zur Unterbrechung und Wiederherstellung der Anschlussnutzung,SG4,NAD,3164,,,,Ort,, - 199,Name und Anschrift Ansprechpartner Prozesse zur Unterbrechung und Wiederherstellung der Anschlussnutzung,SG4,NAD,3251,,,,Postleitzahl,,"[2] Wenn der Code im DE3207 in der ""EDI@Energy Codeliste der europäischen Ländercodes"" in der Spalte ""PLZ vorhanden"" ein ""X"" enthält - [3] wenn vorhanden" - 200,Name und Anschrift Ansprechpartner Prozesse zur Unterbrechung und Wiederherstellung der Anschlussnutzung,SG4,NAD,3207,,,,"Ländername, Code",, - 201,Ansprechpartner,SG7,,,,,,,, - 202,Ansprechpartner,SG7,CTA,,,,,,, - 203,Ansprechpartner,SG7,CTA,3139,,IC,,Informationskontakt,, - 204,Ansprechpartner,SG7,CTA,3412,,,,Name der organisatorischenEinheit,,[501] Hinweis: Es darf kein Name einer natürlichen Person - 205,Kommunikationsverbindung,SG7,COM,,,,,,, - 206,Kommunikationsverbindung,SG7,COM,3148,,,,Nummer / Adresse,,"[6] wenn im DE3155 im demselben COM der Code EM vorhanden ist - [8] wenn im DE3155 im demselben COM der Code TE / FX vorhanden ist - [502] Hinweis: Es darf nur eine Information im DE3148 übermittelt werden - [939] Format: Die Zeichenkette muss die Zeichen @ und . enthalten - [940] Format: Die Zeichenkette muss mit dem Zeichen + beginnen und danach dürfen nur noch Ziffern folgen" - 207,Kommunikationsverbindung,SG7,COM,3155,,EM,,Elektronische Post,, - 208,Kommunikationsverbindung,SG7,COM,3155,,TE,,Telefon,, - 209,Kommunikationsverbindung,SG7,COM,3155,,FX,,Telefax,, - 210,Name und Anschrift Ansprechpartner Bilanzierungsprozesse / Bilanzkreismanagement,SG4,,,,,,,Muss [10],"[10] Wenn BGM DE1373 = 11 (Dokument nicht verfügbar) nicht vorhanden - [26] Wenn MP-ID in SG2 NAD+MR (Nachrichtenempfänger) in der Rolle NB/LF/BKV/ BIKO" - 211,Name und Anschrift Ansprechpartner Bilanzierungsprozesse / Bilanzkreismanagement,SG4,NAD,,,,,,Muss, - 212,Name und Anschrift Ansprechpartner Bilanzierungsprozesse / Bilanzkreismanagement,SG4,NAD,3035,,Z21,,AnsprechpartnerBilanzierungsprozesse /Bilanzkreismanagement,X, - 213,Name und Anschrift Ansprechpartner Bilanzierungsprozesse / Bilanzkreismanagement,SG4,NAD,3036,,,,Name,X [500],[500] Hinweis: Es kann der Firmenname eines Dienstleisters oder die identische Firmenbezeichnung aus SG4 NAD+SU / DDM / DEB / Z31 / Z34 / Z35 / Z36 eingetragen werden. - 214,Name und Anschrift Ansprechpartner Bilanzierungsprozesse / Bilanzkreismanagement,SG4,NAD,3045,,Z02,,Struktur derFirmenbezeichnung,X, - 215,Name und Anschrift Ansprechpartner Bilanzierungsprozesse / Bilanzkreismanagement,SG4,NAD,3042,,,,Straße und Hausnummer oderPostfach,X, - 216,Name und Anschrift Ansprechpartner Bilanzierungsprozesse / Bilanzkreismanagement,SG4,NAD,3164,,,,Ort,X, - 217,Name und Anschrift Ansprechpartner Bilanzierungsprozesse / Bilanzkreismanagement,SG4,NAD,3251,,,,Postleitzahl,M [2]S [3],"[2] Wenn der Code im DE3207 in der ""EDI@Energy Codeliste der europäischen Ländercodes"" in der Spalte ""PLZ vorhanden"" ein ""X"" enthält - [3] wenn vorhanden" - 218,Name und Anschrift Ansprechpartner Bilanzierungsprozesse / Bilanzkreismanagement,SG4,NAD,3207,,,,"Ländername, Code",X, - 219,Ansprechpartner,SG7,,,,,,,Muss, - 220,Ansprechpartner,SG7,CTA,,,,,,Muss, - 221,Ansprechpartner,SG7,CTA,3139,,IC,,Informationskontakt,X, - 222,Ansprechpartner,SG7,CTA,3412,,,,Name der organisatorischenEinheit,X [501],"[501] Hinweis: Es darf kein Name einer natürlichen Person übermittelt werden, stattdessen ist die organisatorische Einheit im Unternehmen zu nennen." - 223,Kommunikationsverbindung,SG7,COM,,,,,,Muss, - 224,Kommunikationsverbindung,SG7,COM,3148,,,,Nummer / Adresse,X (([939][6])∨ ([940][8]))∧ [502],"[6] wenn im DE3155 im demselben COM der Code EM vorhanden ist - [8] wenn im DE3155 im demselben COM der" - 225,Kommunikationsverbindung,SG7,COM,3155,,EM,,Elektronische Post,X [1P1..1], - 226,Kommunikationsverbindung,SG7,COM,3155,,TE,,Telefon,X [1P1..1], - 227,Kommunikationsverbindung,SG7,COM,3155,,FX,,Telefax,X [1P0..1], - 228,Nachrichten-Endesegment,,UNT,,,,,,Muss, - 229,Nachrichten-Endesegment,,UNT,0074,,,,Anzahl der Segmente in einerNachricht,X, - 230,Nachrichten-Endesegment,,UNT,0062,,,,Nachrichten-Referenznummer,X, - - ''', - '37005.csv': ''' - ,Segmentname,Segmentgruppe,Segment,Datenelement,Segment ID,Code,Qualifier,Beschreibung,Bedingungsausdruck,Bedingung - 0,Nachrichten-Kopfsegment,,UNH,,,,,,Muss, - 1,Nachrichten-Kopfsegment,,UNH,0062,,,,Nachrichten-Referenznummer,X, - 2,Nachrichten-Kopfsegment,,UNH,0065,,PARTIN,,Partnerstammdaten,X, - 3,Nachrichten-Kopfsegment,,UNH,0052,,D,,Entwurfs-Version,X, - 4,Nachrichten-Kopfsegment,,UNH,0054,,20B,,Ausgabe 2020 - B,X, - 5,Nachrichten-Kopfsegment,,UNH,0051,,UN,,UN/CEFACT,X, - 6,Nachrichten-Kopfsegment,,UNH,0057,,1.0c,,Versionsnummer derzugrundeliegendenBDEW-Nachrichtenbeschreibung,X, - 7,Beginn der Nachricht,,BGM,,,,,,Muss, - 8,Beginn der Nachricht,,BGM,1001,,10,,Partnerstammdaten,X, - 9,Beginn der Nachricht,,BGM,1004,,,,Dokumentennummer,X, - 10,Beginn der Nachricht,,BGM,1373,,11,,Dokument nichtverfügbar,S [9],[9] Wenn die Kommunikationsdaten vom Absender nicht mehr aktiv sind. - 11,Nachrichtendatum,,DTM,,,,,,Muss, - 12,Nachrichtendatum,,DTM,2005,,137,,Dokumenten-/Nachrichtendatum/-zeit,X, - 13,Nachrichtendatum,,DTM,2380,,,,"Datum oder Uhrzeit oderZeitspanne, Wert",X [931][494],"[494] Das hier genannte Datum muss der Zeitpunkt sein, zu dem das Dokument erstellt wurde, oder ein Zeitpunkt, der davor liegt. - [931] Format: ZZZ = +00" - 14,Nachrichtendatum,,DTM,2379,,303,,CCYYMMDDHHMMZZZ,X, - 15,Prüfidentifikator,SG1,,,,,,,Muss, - 16,Prüfidentifikator,SG1,RFF,,,,,,Muss, - 17,Prüfidentifikator,SG1,RFF,1153,,Z13,,Prüfidentifikator,X, - 18,Prüfidentifikator,SG1,RFF,1154,,37003,,ÜbermittlungKommunikationsdatendes BKV,, - 19,Prüfidentifikator,SG1,RFF,1154,,37004,,ÜbermittlungKommunikationsdatendes BIKO,, - 20,Prüfidentifikator,SG1,RFF,1154,,37005,,ÜbermittlungKommunikationsdatendes ÜNB,X, - 21,Versionsnummer,SG1,,,,,,,Muss, - 22,Versionsnummer,SG1,RFF,,,,,,Muss, - 23,Versionsnummer,SG1,RFF,1153,,AGK,,Anwendungsreferenznummer,X, - 24,Versionsnummer,SG1,RFF,1056,,,,Versionsnummer,X [908][505],"[505] Wenn eine Vorgängerversion (RFF+ACW) angegeben ist, so muss der Wert in diesem DE1056 mindestens um 1 höher sein, als der Wert aus DE1056 der Vorgängerversion (RFF+ACW). - [908] Format: Mögliche Werte: 1 bis n" - 25,Gültig Ab,SG1,DTM,,,,,,Soll [4],[4] Wenn Vorgängerversion vorhanden - 26,Gültig Ab,SG1,DTM,2005,,157,,"Gültigkeit, Beginndatum",X, - 27,Gültig Ab,SG1,DTM,2380,,,,"Datum oder Uhrzeit oderZeitspanne, Wert",X [UB1], - 28,Gültig Ab,SG1,DTM,2379,,303,,CCYYMMDDHHMMZZZ,X, - 29,Vorgängerversion,SG1,,,,,,,Soll [4],[4] Wenn Vorgängerversion vorhanden - 30,Vorgängerversion,SG1,RFF,,,,,,Muss, - 31,Vorgängerversion,SG1,RFF,1153,,ACW,,Referenznummer einervorangegangenenNachricht,X, - 32,Vorgängerversion,SG1,RFF,1056,,,,Versionsnummer,X [908],[908] Format: Mögliche Werte: 1 bis n - 33,MP-ID Absender,SG2,,,,,,,Muss, - 34,MP-ID Absender,SG2,NAD,,,,,,Muss, - 35,MP-ID Absender,SG2,NAD,3035,,MS,,Dokumenten-/Nachrichtenausstellerbzw. -absender,X, - 36,MP-ID Absender,SG2,NAD,3039,,,,MP-ID,X [1],[1] Nur MP-ID aus Sparte Strom - 37,MP-ID Absender,SG2,NAD,3055,,9,,GS1,X, - 38,MP-ID Absender,SG2,NAD,3055,,293,,"DE, BDEW",X, - 39,Ansprechpartner,SG3,,,,,,,Kann, - 40,Ansprechpartner,SG3,CTA,,,,,,Muss, - 41,Ansprechpartner,SG3,CTA,3139,,IC,,Informationskontakt,X, - 42,Ansprechpartner,SG3,CTA,3412,,,,Name vom Ansprechpartner,X, - 43,Kommunikationsverbindung,SG3,COM,,,,,,Muss, - 44,Kommunikationsverbindung,SG3,COM,3148,,,,Nummer / Adresse,X (([939][6])∨ ([940][7]))∧ [502],"[6] wenn im DE3155 im demselben COM der Code EM vorhanden ist - [7] wenn im DE3155 im demselben COM der Code TE / FX / AJ / AL vorhanden ist - [502] Hinweis: Es darf nur eine Information im DE3148 übermittelt werden - [939] Format: Die Zeichenkette muss die Zeichen @ und . enthalten - [940] Format: Die Zeichenkette muss mit dem Zeichen + beginnen und danach dürfen nur noch Ziffern folgen" - 45,Kommunikationsverbindung,SG3,COM,3155,,EM,,Elektronische Post,X [1P0..1], - 46,Kommunikationsverbindung,SG3,COM,3155,,FX,,Telefax,X [1P0..1], - 47,Kommunikationsverbindung,SG3,COM,3155,,TE,,Telefon,X [1P0..1], - 48,Kommunikationsverbindung,SG3,COM,3155,,AJ,,weiteres Telefon,X [1P0..1], - 49,Kommunikationsverbindung,SG3,COM,3155,,AL,,Handy,X [1P0..1], - 50,MP-ID Empfänger,SG2,,,,,,,Muss, - 51,MP-ID Empfänger,SG2,NAD,,,,,,Muss, - 52,MP-ID Empfänger,SG2,NAD,3035,,MR,,Nachrichtenempfänger,X, - 53,MP-ID Empfänger,SG2,NAD,3039,,,,MP-ID,X [1],[1] Nur MP-ID aus Sparte Strom - 54,MP-ID Empfänger,SG2,NAD,3055,,9,,GS1,X, - 55,MP-ID Empfänger,SG2,NAD,3055,,293,,"DE, BDEW",X, - 56,Abschnitts-Kontrollsegment,,UNS,,,,,,Muss, - 57,Abschnitts-Kontrollsegment,,UNS,0081,,D,,Trennung von Kopf- undPositionsteil,X, - 58,Name und Adresse des Unternehmens,SG4,,,,,,,Muss [10],[10] Wenn BGM DE1373 = 11 (Dokument nicht verfügbar) nicht vorhanden - 59,Name und Adresse des Unternehmens,SG4,NAD,,,,,,Muss, - 60,Name und Adresse des Unternehmens,SG4,NAD,3035,,Z31,,Übertragungsnetzbetreiber,X, - 61,Name und Adresse des Unternehmens,SG4,NAD,3035,,Z34,,Bilanzkoordinator,, - 62,Name und Adresse des Unternehmens,SG4,NAD,3035,,Z35,,Bilanzkreisverantwortlicher,, - 63,Name und Adresse des Unternehmens,SG4,NAD,3036,,,,Name,X [506],"[506] Hinweis: Das Datenelement ist so zu füllen, dass sein Inhalt den Vorgaben des USt.- Gesetzes genügt, so dass der Empfänger diese Daten in einer INVOIC nutzen kann." - 64,Name und Adresse des Unternehmens,SG4,NAD,3045,,Z02,,Struktur derFirmenbezeichnung,X, - 65,Name und Adresse des Unternehmens,SG4,NAD,3042,,,,Straße und Hausnummer oderPostfach,X [506],"[506] Hinweis: Das Datenelement ist so zu füllen, dass sein Inhalt den Vorgaben des USt.- Gesetzes genügt, so dass der Empfänger diese Daten in einer INVOIC nutzen kann." - 66,Name und Adresse des Unternehmens,SG4,NAD,3164,,,,Ort,X [506],"[506] Hinweis: Das Datenelement ist so zu füllen, dass sein Inhalt den Vorgaben des USt.- Gesetzes genügt, so dass der Empfänger diese Daten in einer INVOIC nutzen kann." - 67,Name und Adresse des Unternehmens,SG4,NAD,3251,,,,Postleitzahl,M [2] ∧[506]S [3] ∧ [506],"[2] Wenn der Code im DE3207 in der ""EDI@Energy Codeliste der europäischen" - 68,Name und Adresse des Unternehmens,SG4,NAD,3207,,,,"Ländername, Code",X [506],"[506] Hinweis: Das Datenelement ist so zu füllen, dass sein Inhalt den Vorgaben des USt.- Gesetzes genügt, so dass der Empfänger diese Daten in einer INVOIC nutzen kann." - 69,Bankverbindung,SG4,FII,,,,,,Muss, - 70,Bankverbindung,SG4,FII,3035,,BK,,Kreditinstitut,X, - 71,Bankverbindung,SG4,FII,3194,,IBAN,,,X, - 72,Bankverbindung,SG4,FII,3192,,,,Name des Kontoinhabers,X, - 73,Bankverbindung,SG4,FII,3192,,,,Name des Kontoinhabers,K, - 74,Bankverbindung,SG4,FII,3433,,BIC,,,X, - 75,Bankverbindung,SG4,FII,3432,,,,Name des Kredinstituts,X, - 76,Internetseite (URL),SG4,FTX,,,,,,Muss, - 77,Internetseite (URL),SG4,FTX,4451,,Z13,,Internetseite,X, - 78,Internetseite (URL),SG4,FTX,4440,,,,Internetseite,X, - 79,Gericht und Handelsregister-Nummer,SG4,FTX,,,,,,Soll [3],[3] wenn vorhanden - 80,Gericht und Handelsregister-Nummer,SG4,FTX,4451,,Z15,,Gericht undHandelsregister-Nummer,X, - 81,Gericht und Handelsregister-Nummer,SG4,FTX,4440,,,,Gericht,X, - 82,Gericht und Handelsregister-Nummer,SG4,FTX,4440,,,,Handelsregister-Nummer,X, - 83,"Steuernummer, Umsatzsteuernummer",SG6,,,,,,,Muss, - 84,"Steuernummer, Umsatzsteuernummer",SG6,RFF,,,,,,Muss, - 85,"Steuernummer, Umsatzsteuernummer",SG6,RFF,1153,,VA,,Umsatzsteuernummer,X [2P0..1] ⊻[3P1..1], - 86,"Steuernummer, Umsatzsteuernummer",SG6,RFF,1153,,FC,,Steuernummer,X [2P0..1], - 87,"Steuernummer, Umsatzsteuernummer",SG6,RFF,1154,,,,"Referenz, Identifikation",X, - 88,Faxnummer,SG6,RFF,,,,,,Kann, - 89,Faxnummer,SG6,RFF,1153,,Z25,,Faxnummer,X, - 90,Faxnummer,SG6,RFF,1154,,,,Faxnummer,X [940],[940] Format: Die Zeichenkette muss mit dem Zeichen + beginnen und danach dürfen nur noch Ziffern folgen - 91,Erreichbarkeit an Werktagen,SG12,,,,,,,Muss, - 92,Erreichbarkeit an Werktagen,SG12,CCI,,,,,,Muss, - 93,Erreichbarkeit an Werktagen,SG12,CCI,7059,,Z40,,Erreichbarkeit desUnternehmens,X, - 94,Erreichbarkeit,SG12,DTM,,,,,,Muss, - 95,Erreichbarkeit,SG12,DTM,2005,,Z36,,Verfügbarkeit Montag,X [1P1..1], - 96,Erreichbarkeit,SG12,DTM,2005,,Z37,,Verfügbarkeit Dienstag,X [1P1..1], - 97,Erreichbarkeit,SG12,DTM,2005,,Z38,,Verfügbarkeit Mittwoch,X [1P1..1], - 98,Erreichbarkeit,SG12,DTM,2005,,Z39,,VerfügbarkeitDonnerstag,X [1P1..1], - 99,Erreichbarkeit,SG12,DTM,2005,,Z40,,Verfügbarkeit Freitag,X [1P1..1], - 100,Erreichbarkeit,SG12,DTM,2005,,Z41,,Mittagspause (=Ausschluss derVerfügbarkeit),X [1P0..1], - 101,Erreichbarkeit,SG12,DTM,2380,,,,"Datum oder Uhrzeit oderZeitspanne, Wert",X [503],[503] Hinweis: Angabe erfolgt in gesetzlicher deutscher Zeit - 102,Erreichbarkeit,SG12,DTM,2379,,501,,HHMMHHMM,X, - 103,Name und Anschrift Ansprechpartner Übertragungsweg / Datenaustausch,SG4,,,,,,,Muss [10],[10] Wenn BGM DE1373 = 11 (Dokument nicht verfügbar) nicht vorhanden - 104,Name und Anschrift Ansprechpartner Übertragungsweg / Datenaustausch,SG4,NAD,,,,,,Muss, - 105,Name und Anschrift Ansprechpartner Übertragungsweg / Datenaustausch,SG4,NAD,3035,,Z10,,Ansprechpartner,X, - 106,Name und Anschrift Ansprechpartner Übertragungsweg / Datenaustausch,SG4,NAD,3036,,,,Name,X [500],[500] Hinweis: Es kann der Firmenname eines Dienstleisters oder die identische Firmenbezeichnung aus SG4 NAD+SU / DDM / DEB / Z31 / Z34 / Z35 / Z36 eingetragen werden. - 107,Name und Anschrift Ansprechpartner Übertragungsweg / Datenaustausch,SG4,NAD,3045,,Z02,,Struktur derFirmenbezeichnung,X, - 108,Name und Anschrift Ansprechpartner Übertragungsweg / Datenaustausch,SG4,NAD,3042,,,,Straße und Hausnummer oderPostfach,X, - 109,Name und Anschrift Ansprechpartner Übertragungsweg / Datenaustausch,SG4,NAD,3164,,,,Ort,X, - 110,Name und Anschrift Ansprechpartner Übertragungsweg / Datenaustausch,SG4,NAD,3251,,,,Postleitzahl,M [2]S [3],"[2] Wenn der Code im DE3207 in der ""EDI@Energy Codeliste der europäischen Ländercodes"" in der Spalte ""PLZ vorhanden"" ein ""X"" enthält - [3] wenn vorhanden" - 111,Name und Anschrift Ansprechpartner Übertragungsweg / Datenaustausch,SG4,NAD,3207,,,,"Ländername, Code",X, - 112,Ansprechpartner,SG7,,,,,,,Muss, - 113,Ansprechpartner,SG7,CTA,,,,,,Muss, - 114,Ansprechpartner,SG7,CTA,3139,,IC,,Informationskontakt,X, - 115,Ansprechpartner,SG7,CTA,3412,,,,Name der organisatorischenEinheit,X [501],"[501] Hinweis: Es darf kein Name einer natürlichen Person übermittelt werden, stattdessen ist die organisatorische Einheit im Unternehmen zu nennen." - 116,Kommunikationsverbindung,SG7,COM,,,,,,Muss, - 117,Kommunikationsverbindung,SG7,COM,3148,,,,Nummer / Adresse,X (([939][6])∨ ([940][8]))∧ [502],"[6] wenn im DE3155 im demselben COM der Code EM vorhanden ist - [8] wenn im DE3155 im demselben COM der Code TE / FX vorhanden ist" - 118,Kommunikationsverbindung,SG7,COM,3155,,EM,,Elektronische Post,X [1P1..1], - 119,Kommunikationsverbindung,SG7,COM,3155,,TE,,Telefon,X [1P1..1], - 120,Kommunikationsverbindung,SG7,COM,3155,,FX,,Telefax,X [1P0..1], - 121,Name und Anschrift Ansprechpartner Rahmenverträge,SG4,,,,,,,Muss [10] ∧[36],"[10] Wenn BGM DE1373 = 11 (Dokument nicht verfügbar) nicht vorhanden - [35] Wenn MP-ID in SG2 NAD+MR (Nachrichtenempfänger) in der Rolle ÜNB - [36] Wenn MP-ID in SG2 NAD+MR (Nachrichtenempfänger) in der Rolle BKV" - 122,Name und Anschrift Ansprechpartner Rahmenverträge,SG4,NAD,,,,,,Muss, - 123,Name und Anschrift Ansprechpartner Rahmenverträge,SG4,NAD,3035,,Z11,,AnsprechpartnerRahmenverträge,X, - 124,Name und Anschrift Ansprechpartner Rahmenverträge,SG4,NAD,3036,,,,Name,X [500],[500] Hinweis: Es kann der Firmenname eines Dienstleisters oder die identische Firmenbezeichnung aus SG4 NAD+SU / DDM / DEB / Z31 / Z34 / Z35 / Z36 eingetragen werden. - 125,Name und Anschrift Ansprechpartner Rahmenverträge,SG4,NAD,3045,,Z02,,Struktur derFirmenbezeichnung,X, - 126,Name und Anschrift Ansprechpartner Rahmenverträge,SG4,NAD,3042,,,,Straße und Hausnummer oder,X, - 127,Name und Anschrift Ansprechpartner Rahmenverträge,SG4,NAD,3164,,,,Ort,X, - 128,Name und Anschrift Ansprechpartner Rahmenverträge,SG4,NAD,3251,,,,Postleitzahl,M [2]S [3],"[2] Wenn der Code im DE3207 in der ""EDI@Energy Codeliste der europäischen Ländercodes"" in der Spalte ""PLZ vorhanden"" ein ""X"" enthält - [3] wenn vorhanden" - 129,Name und Anschrift Ansprechpartner Rahmenverträge,SG4,NAD,3207,,,,"Ländername, Code",X, - 130,Ansprechpartner,SG7,,,,,,,Muss, - 131,Ansprechpartner,SG7,CTA,,,,,,Muss, - 132,Ansprechpartner,SG7,CTA,3139,,IC,,Informationskontakt,X, - 133,Ansprechpartner,SG7,CTA,3412,,,,Name der organisatorischenEinheit,X [501],"[501] Hinweis: Es darf kein Name einer natürlichen Person übermittelt werden, stattdessen ist die organisatorische Einheit im Unternehmen zu nennen." - 134,Kommunikationsverbindung,SG7,COM,,,,,,Muss, - 135,Kommunikationsverbindung,SG7,COM,3148,,,,Nummer / Adresse,X (([939][6])∨ ([940][8]))∧ [502],"[6] wenn im DE3155 im demselben COM der Code EM vorhanden ist - [8] wenn im DE3155 im demselben COM der Code TE / FX vorhanden ist - [502] Hinweis: Es darf nur eine Information im DE3148 übermittelt werden - [939] Format: Die Zeichenkette muss die Zeichen @ und . enthalten - [940] Format: Die Zeichenkette muss mit dem Zeichen + beginnen" - 136,Kommunikationsverbindung,SG7,COM,3155,,EM,,Elektronische Post,X [1P1..1], - 137,Kommunikationsverbindung,SG7,COM,3155,,TE,,Telefon,X [1P1..1], - 138,Kommunikationsverbindung,SG7,COM,3155,,FX,,Telefax,X [1P0..1], - 139,Name und Anschrift Ansprechpartner Stammdatenprozesse,SG4,,,,,,,Muss [10] ∧[17],"[10] Wenn BGM DE1373 = 11 (Dokument nicht verfügbar) nicht vorhanden - [17] Wenn MP-ID in SG2 NAD+MR (Nachrichtenempfänger) in der Rolle LF/NB/MSB" - 140,Name und Anschrift Ansprechpartner Stammdatenprozesse,SG4,NAD,,,,,,Muss, - 141,Name und Anschrift Ansprechpartner Stammdatenprozesse,SG4,NAD,3035,,Z14,,AnsprechpartnerStammdatenprozesse,X, - 142,Name und Anschrift Ansprechpartner Stammdatenprozesse,SG4,NAD,3036,,,,Name,X [500],[500] Hinweis: Es kann der Firmenname eines Dienstleisters oder die identische Firmenbezeichnung aus SG4 NAD+SU / DDM / DEB / Z31 / Z34 / Z35 / Z36 eingetragen werden. - 143,Name und Anschrift Ansprechpartner Stammdatenprozesse,SG4,NAD,3045,,Z02,,Struktur derFirmenbezeichnung,X, - 144,Name und Anschrift Ansprechpartner Stammdatenprozesse,SG4,NAD,3042,,,,Straße und Hausnummer oderPostfach,X, - 145,Name und Anschrift Ansprechpartner Stammdatenprozesse,SG4,NAD,3164,,,,Ort,X, - 146,Name und Anschrift Ansprechpartner Stammdatenprozesse,SG4,NAD,3251,,,,Postleitzahl,M [2]S [3],"[2] Wenn der Code im DE3207 in der ""EDI@Energy Codeliste der europäischen Ländercodes"" in der Spalte ""PLZ vorhanden"" ein ""X"" enthält - [3] wenn vorhanden" - 147,Name und Anschrift Ansprechpartner Stammdatenprozesse,SG4,NAD,3207,,,,"Ländername, Code",X, - 148,Ansprechpartner,SG7,,,,,,,Muss, - 149,Ansprechpartner,SG7,CTA,,,,,,Muss, - 150,Ansprechpartner,SG7,CTA,3139,,IC,,Informationskontakt,X, - 151,Ansprechpartner,SG7,CTA,3412,,,,Name der organisatorischen,X [501],[501] Hinweis: Es darf - 152,Kommunikationsverbindung,SG7,COM,,,,,,Muss, - 153,Kommunikationsverbindung,SG7,COM,3148,,,,Nummer / Adresse,X (([939][6])∨ ([940][8]))∧ [502],"[6] wenn im DE3155 im demselben COM der Code EM vorhanden ist - [8] wenn im DE3155 im demselben COM der Code TE / FX vorhanden ist - [502] Hinweis: Es darf nur eine Information im DE3148 übermittelt werden - [939] Format: Die Zeichenkette muss die Zeichen @ und . enthalten - [940] Format: Die Zeichenkette muss mit dem Zeichen + beginnen und danach dürfen nur noch Ziffern folgen" - 154,Kommunikationsverbindung,SG7,COM,3155,,EM,,Elektronische Post,X [1P1..1], - 155,Kommunikationsverbindung,SG7,COM,3155,,TE,,Telefon,X [1P1..1], - 156,Kommunikationsverbindung,SG7,COM,3155,,FX,,Telefax,X [1P0..1], - 157,Name und Anschrift Ansprechpartner MMMA- Prozesse,SG4,,,,,,,Muss [10] ∧ [25],"[10] Wenn BGM DE1373 = 11 (Dokument nicht verfügbar) nicht vorhanden - [25] Wenn MP-ID in SG2 NAD+MR (Nachrichtenempfänger) in der Rolle NB" - 158,Name und Anschrift Ansprechpartner MMMA- Prozesse,SG4,NAD,,,,,,Muss, - 159,Name und Anschrift Ansprechpartner MMMA- Prozesse,SG4,NAD,3035,,Z18,,AnsprechpartnerMMMA-Prozesse,X, - 160,Name und Anschrift Ansprechpartner MMMA- Prozesse,SG4,NAD,3036,,,,Name,X [500],[500] Hinweis: Es kann der Firmenname eines Dienstleisters oder die identische Firmenbezeichnung aus SG4 NAD+SU / DDM / DEB / Z31 / Z34 / Z35 / Z36 eingetragen werden. - 161,Name und Anschrift Ansprechpartner MMMA- Prozesse,SG4,NAD,3045,,Z02,,Struktur derFirmenbezeichnung,X, - 162,Name und Anschrift Ansprechpartner MMMA- Prozesse,SG4,NAD,3042,,,,Straße und Hausnummer oderPostfach,X, - 163,Name und Anschrift Ansprechpartner MMMA- Prozesse,SG4,NAD,3164,,,,Ort,X, - 164,Name und Anschrift Ansprechpartner MMMA- Prozesse,SG4,NAD,3251,,,,Postleitzahl,M [2]S [3],"[2] Wenn der Code im DE3207 in der ""EDI@Energy Codeliste der europäischen Ländercodes"" in der Spalte ""PLZ vorhanden"" ein ""X"" enthält - [3] wenn vorhanden" - 165,Name und Anschrift Ansprechpartner MMMA- Prozesse,SG4,NAD,3207,,,,"Ländername, Code",X, - 166,Ansprechpartner,SG7,,,,,,,Muss, - 167,Ansprechpartner,SG7,CTA,,,,,,Muss, - 168,Ansprechpartner,SG7,CTA,3139,,IC,,Informationskontakt,X, - 169,Ansprechpartner,SG7,CTA,3412,,,,Name der organisatorischenEinheit,X [501],"[501] Hinweis: Es darf kein Name einer natürlichen Person übermittelt werden, stattdessen ist die organisatorische Einheit im Unternehmen zu nennen." - 170,Kommunikationsverbindung,SG7,COM,,,,,,Muss, - 171,Kommunikationsverbindung,SG7,COM,3148,,,,Nummer / Adresse,X (([939][6])∨ ([940][8]))∧ [502],"[6] wenn im DE3155 im demselben COM der Code EM vorhanden ist - [8] wenn im DE3155 im demselben COM der Code TE / FX vorhanden" - 172,Kommunikationsverbindung,SG7,COM,3155,,EM,,Elektronische Post,X [1P1..1], - 173,Kommunikationsverbindung,SG7,COM,3155,,TE,,Telefon,X [1P1..1], - 174,Kommunikationsverbindung,SG7,COM,3155,,FX,,Telefax,X [1P0..1], - 175,Name und Anschrift Bewegungsdaten,SG4,,,,,,,Muss [10] ∧[17],"[10] Wenn BGM DE1373 = 11 (Dokument nicht verfügbar) nicht vorhanden - [17] Wenn MP-ID in SG2 NAD+MR (Nachrichtenempfänger) in der Rolle LF/NB/MSB" - 176,Name und Anschrift Bewegungsdaten,SG4,NAD,,,,,,Muss, - 177,Name und Anschrift Bewegungsdaten,SG4,NAD,3035,,Z19,,AnsprechpartnerBewegungsdaten,X, - 178,Name und Anschrift Bewegungsdaten,SG4,NAD,3036,,,,Name,X [500],[500] Hinweis: Es kann der Firmenname eines Dienstleisters oder die identische Firmenbezeichnung aus SG4 NAD+SU / DDM / DEB / Z31 / Z34 / Z35 / Z36 eingetragen werden. - 179,Name und Anschrift Bewegungsdaten,SG4,NAD,3045,,Z02,,Struktur derFirmenbezeichnung,X, - 180,Name und Anschrift Bewegungsdaten,SG4,NAD,3042,,,,Straße und Hausnummer oderPostfach,X, - 181,Name und Anschrift Bewegungsdaten,SG4,NAD,3164,,,,Ort,X, - 182,Name und Anschrift Bewegungsdaten,SG4,NAD,3251,,,,Postleitzahl,M [2]S [3],[2] Wenn der Code im DE3207 in der - 183,Name und Anschrift Bewegungsdaten,SG4,NAD,3207,,,,"Ländername, Code",X, - 184,Ansprechpartner,SG7,,,,,,,Muss, - 185,Ansprechpartner,SG7,CTA,,,,,,Muss, - 186,Ansprechpartner,SG7,CTA,3139,,IC,,Informationskontakt,X, - 187,Ansprechpartner,SG7,CTA,3412,,,,Name der organisatorischenEinheit,X [501],"[501] Hinweis: Es darf kein Name einer natürlichen Person übermittelt werden, stattdessen ist die organisatorische Einheit im Unternehmen zu nennen." - 188,Kommunikationsverbindung,SG7,COM,,,,,,Muss, - 189,Kommunikationsverbindung,SG7,COM,3148,,,,Nummer / Adresse,X (([939][6])∨ ([940][8]))∧ [502],"[6] wenn im DE3155 im demselben COM der Code EM vorhanden ist - [8] wenn im DE3155 im demselben COM der Code TE / FX vorhanden ist - [502] Hinweis: Es darf nur eine Information im DE3148 übermittelt werden - [939] Format: Die Zeichenkette muss die Zeichen @ und . enthalten - [940] Format: Die Zeichenkette muss mit dem Zeichen + beginnen und danach dürfen nur noch Ziffern folgen" - 190,Kommunikationsverbindung,SG7,COM,3155,,EM,,Elektronische Post,X [1P1..1], - 191,Kommunikationsverbindung,SG7,COM,3155,,TE,,Telefon,X [1P1..1], - 192,Name und Anschrift Ansprechpartner Prozesse zur Unterbrechung und Wiederherstellung der Anschlussnutzung,SG4,,,,,,,Muss [10] ∧[25],"[10] Wenn BGM DE1373 = 11 (Dokument nicht verfügbar) nicht vorhanden - [25] Wenn MP-ID in SG2 NAD+MR (Nachrichtenempfänger) in der Rolle NB" - 193,Name und Anschrift Ansprechpartner Prozesse zur Unterbrechung und Wiederherstellung der Anschlussnutzung,SG4,NAD,,,,,,Muss, - 194,Name und Anschrift Ansprechpartner Prozesse zur Unterbrechung und Wiederherstellung der Anschlussnutzung,SG4,NAD,3035,,Z20,,AnsprechpartnerSperr-/Entsperrprozesse,X, - 195,Name und Anschrift Ansprechpartner Prozesse zur Unterbrechung und Wiederherstellung der Anschlussnutzung,SG4,NAD,3036,,,,Name,X [500],[500] Hinweis: Es kann der Firmenname eines Dienstleisters oder die identische Firmenbezeichnung aus SG4 NAD+SU / DDM / DEB / Z31 / Z34 / Z35 / Z36 eingetragen werden. - 196,Name und Anschrift Ansprechpartner Prozesse zur Unterbrechung und Wiederherstellung der Anschlussnutzung,SG4,NAD,3045,,Z02,,Struktur derFirmenbezeichnung,X, - 197,Name und Anschrift Ansprechpartner Prozesse zur Unterbrechung und Wiederherstellung der Anschlussnutzung,SG4,NAD,3042,,,,Straße und Hausnummer oderPostfach,X, - 198,Name und Anschrift Ansprechpartner Prozesse zur Unterbrechung und Wiederherstellung der Anschlussnutzung,SG4,NAD,3164,,,,Ort,X, - 199,Name und Anschrift Ansprechpartner Prozesse zur Unterbrechung und Wiederherstellung der Anschlussnutzung,SG4,NAD,3251,,,,Postleitzahl,M [2]S [3],"[2] Wenn der Code im DE3207 in der ""EDI@Energy Codeliste der europäischen Ländercodes"" in der Spalte ""PLZ vorhanden"" ein ""X"" enthält - [3] wenn vorhanden" - 200,Name und Anschrift Ansprechpartner Prozesse zur Unterbrechung und Wiederherstellung der Anschlussnutzung,SG4,NAD,3207,,,,"Ländername, Code",X, - 201,Ansprechpartner,SG7,,,,,,,Muss, - 202,Ansprechpartner,SG7,CTA,,,,,,Muss, - 203,Ansprechpartner,SG7,CTA,3139,,IC,,Informationskontakt,X, - 204,Ansprechpartner,SG7,CTA,3412,,,,Name der organisatorischenEinheit,X [501],[501] Hinweis: Es darf kein Name einer natürlichen Person - 205,Kommunikationsverbindung,SG7,COM,,,,,,Muss, - 206,Kommunikationsverbindung,SG7,COM,3148,,,,Nummer / Adresse,X (([939][6])∨ ([940][8]))∧ [502],"[6] wenn im DE3155 im demselben COM der Code EM vorhanden ist - [8] wenn im DE3155 im demselben COM der Code TE / FX vorhanden ist - [502] Hinweis: Es darf nur eine Information im DE3148 übermittelt werden - [939] Format: Die Zeichenkette muss die Zeichen @ und . enthalten - [940] Format: Die Zeichenkette muss mit dem Zeichen + beginnen und danach dürfen nur noch Ziffern folgen" - 207,Kommunikationsverbindung,SG7,COM,3155,,EM,,Elektronische Post,X [1P1..1], - 208,Kommunikationsverbindung,SG7,COM,3155,,TE,,Telefon,X [1P1..1], - 209,Kommunikationsverbindung,SG7,COM,3155,,FX,,Telefax,X [1P0..1], - 210,Name und Anschrift Ansprechpartner Bilanzierungsprozesse / Bilanzkreismanagement,SG4,,,,,,,Muss [10] ∧[26],"[10] Wenn BGM DE1373 = 11 (Dokument nicht verfügbar) nicht vorhanden - [26] Wenn MP-ID in SG2 NAD+MR (Nachrichtenempfänger) in der Rolle NB/LF/BKV/ BIKO" - 211,Name und Anschrift Ansprechpartner Bilanzierungsprozesse / Bilanzkreismanagement,SG4,NAD,,,,,,Muss, - 212,Name und Anschrift Ansprechpartner Bilanzierungsprozesse / Bilanzkreismanagement,SG4,NAD,3035,,Z21,,AnsprechpartnerBilanzierungsprozesse /Bilanzkreismanagement,X, - 213,Name und Anschrift Ansprechpartner Bilanzierungsprozesse / Bilanzkreismanagement,SG4,NAD,3036,,,,Name,X [500],[500] Hinweis: Es kann der Firmenname eines Dienstleisters oder die identische Firmenbezeichnung aus SG4 NAD+SU / DDM / DEB / Z31 / Z34 / Z35 / Z36 eingetragen werden. - 214,Name und Anschrift Ansprechpartner Bilanzierungsprozesse / Bilanzkreismanagement,SG4,NAD,3045,,Z02,,Struktur derFirmenbezeichnung,X, - 215,Name und Anschrift Ansprechpartner Bilanzierungsprozesse / Bilanzkreismanagement,SG4,NAD,3042,,,,Straße und Hausnummer oderPostfach,X, - 216,Name und Anschrift Ansprechpartner Bilanzierungsprozesse / Bilanzkreismanagement,SG4,NAD,3164,,,,Ort,X, - 217,Name und Anschrift Ansprechpartner Bilanzierungsprozesse / Bilanzkreismanagement,SG4,NAD,3251,,,,Postleitzahl,M [2]S [3],"[2] Wenn der Code im DE3207 in der ""EDI@Energy Codeliste der europäischen Ländercodes"" in der Spalte ""PLZ vorhanden"" ein ""X"" enthält - [3] wenn vorhanden" - 218,Name und Anschrift Ansprechpartner Bilanzierungsprozesse / Bilanzkreismanagement,SG4,NAD,3207,,,,"Ländername, Code",X, - 219,Ansprechpartner,SG7,,,,,,,Muss, - 220,Ansprechpartner,SG7,CTA,,,,,,Muss, - 221,Ansprechpartner,SG7,CTA,3139,,IC,,Informationskontakt,X, - 222,Ansprechpartner,SG7,CTA,3412,,,,Name der organisatorischenEinheit,X [501],"[501] Hinweis: Es darf kein Name einer natürlichen Person übermittelt werden, stattdessen ist die organisatorische Einheit im Unternehmen zu nennen." - 223,Kommunikationsverbindung,SG7,COM,,,,,,Muss, - 224,Kommunikationsverbindung,SG7,COM,3148,,,,Nummer / Adresse,X (([939][6])∨ ([940][8]))∧ [502],"[6] wenn im DE3155 im demselben COM der Code EM vorhanden ist - [8] wenn im DE3155 im demselben COM der" - 225,Kommunikationsverbindung,SG7,COM,3155,,EM,,Elektronische Post,X [1P1..1], - 226,Kommunikationsverbindung,SG7,COM,3155,,TE,,Telefon,X [1P1..1], - 227,Kommunikationsverbindung,SG7,COM,3155,,FX,,Telefax,X [1P0..1], - 228,Nachrichten-Endesegment,,UNT,,,,,,Muss, - 229,Nachrichten-Endesegment,,UNT,0074,,,,Anzahl der Segmente in einerNachricht,X, - 230,Nachrichten-Endesegment,,UNT,0062,,,,Nachrichten-Referenznummer,X, - - ''', - '37006.csv': ''' - ,Segmentname,Segmentgruppe,Segment,Datenelement,Segment ID,Code,Qualifier,Beschreibung,Bedingungsausdruck,Bedingung - 0,Nachrichten-Kopfsegment,,UNH,,,,,,Muss, - 1,Nachrichten-Kopfsegment,,UNH,0062,,,,Nachrichten-Referenznummer,X, - 2,Nachrichten-Kopfsegment,,UNH,0065,,PARTIN,,Partnerstammdaten,X, - 3,Nachrichten-Kopfsegment,,UNH,0052,,D,,Entwurfs-Version,X, - 4,Nachrichten-Kopfsegment,,UNH,0054,,20B,,Ausgabe 2020 - B,X, - 5,Nachrichten-Kopfsegment,,UNH,0051,,UN,,UN/CEFACT,X, - 6,Nachrichten-Kopfsegment,,UNH,0057,,1.0c,,Versionsnummer derzugrundeliegendenBDEW-Nachrichtenbeschreibung,X, - 7,Beginn der Nachricht,,BGM,,,,,,Muss, - 8,Beginn der Nachricht,,BGM,1001,,10,,Partnerstammdaten,X, - 9,Beginn der Nachricht,,BGM,1004,,,,Dokumentennummer,X, - 10,Beginn der Nachricht,,BGM,1373,,,,,11,[9] Wenn die Kommunikationsdaten vom Absender nicht mehr aktiv sind. - 11,Nachrichtendatum,,DTM,,,,,,Muss, - 12,Nachrichtendatum,,DTM,2005,,137,,Dokumenten-/Nachrichtendatum/-zeit,X, - 13,Nachrichtendatum,,DTM,2380,,,,"Datum oder Uhrzeit oderZeitspanne, Wert",X [931][494],"[494] Das hier genannte Datum muss der Zeitpunkt sein, zu dem das Dokument erstellt wurde, oder ein Zeitpunkt, der davor liegt. - [931] Format: ZZZ = +00" - 14,Nachrichtendatum,,DTM,2379,,303,,CCYYMMDDHHMMZZZ,X, - 15,Prüfidentifikator,SG1,,,,,,,Muss, - 16,Prüfidentifikator,SG1,RFF,,,,,,Muss, - 17,Prüfidentifikator,SG1,RFF,1153,,Z13,,Prüfidentifikator,X, - 18,Prüfidentifikator,SG1,RFF,1154,,37006,,ÜbermittlungKommunikationsdaten desESA,X, - 19,Versionsnummer,SG1,,,,,,,Muss, - 20,Versionsnummer,SG1,RFF,,,,,,Muss, - 21,Versionsnummer,SG1,RFF,1153,,AGK,,Anwendungsreferenznummer,X, - 22,Versionsnummer,SG1,RFF,1056,,,,Versionsnummer,X [908][505],"[505] Wenn eine Vorgängerversion (RFF+ACW) angegeben ist, so muss der Wert in diesem DE1056 mindestens um 1 höher sein, als der Wert aus DE1056 der Vorgängerversion (RFF+ACW). - [908] Format: Mögliche Werte: 1" - 23,Gültig Ab,SG1,DTM,,,,,,Soll [4],[4] Wenn Vorgängerversion vorhanden - 24,Gültig Ab,SG1,DTM,2005,,157,,"Gültigkeit, Beginndatum",X, - 25,Gültig Ab,SG1,DTM,2380,,,,"Datum oder Uhrzeit oderZeitspanne, Wert",X [UB1], - 26,Gültig Ab,SG1,DTM,2379,,303,,CCYYMMDDHHMMZZZ,X, - 27,Vorgängerversion,SG1,,,,,,,Soll [4],[4] Wenn Vorgängerversion vorhanden - 28,Vorgängerversion,SG1,RFF,,,,,,Muss, - 29,Vorgängerversion,SG1,RFF,1153,,ACW,,Referenznummer einervorangegangenenNachricht,X, - 30,Vorgängerversion,SG1,RFF,1056,,,,Versionsnummer,X [908],[908] Format: Mögliche Werte: 1 bis n - 31,MP-ID Absender,SG2,,,,,,,Muss, - 32,MP-ID Absender,SG2,NAD,,,,,,Muss, - 33,MP-ID Absender,SG2,NAD,3035,,Nachrichtenaussteller bzw.-absender,,,MS, - 34,MP-ID Absender,SG2,NAD,3039,,,,MP-ID,X [1],[1] Nur MP-ID aus Sparte Strom - 35,MP-ID Absender,SG2,NAD,3055,,9,,GS1,X, - 36,MP-ID Absender,SG2,NAD,3055,,293,,"DE, BDEW (Bundesverbandder Energie- undWasserwirtschaft e.V.)",X, - 37,Ansprechpartner,SG3,,,,,,,Kann, - 38,Ansprechpartner,SG3,CTA,,,,,,Muss, - 39,Ansprechpartner,SG3,CTA,3139,,,,,IC, - 40,Ansprechpartner,SG3,CTA,3412,,,,Name vom Ansprechpartner,X, - 41,Kommunikationsverbindung,SG3,COM,,,,,,Muss, - 42,Kommunikationsverbindung,SG3,COM,3148,,,,Nummer / Adresse,X (([939][6]) ∨ ([940][7]))∧ [502],"[6] wenn im DE3155 im demselben COM der Code EM vorhanden ist - [7] wenn im DE3155 im demselben COM der Code TE / FX / AJ / AL vorhanden ist - [502] Hinweis: Es darf nur eine Information im DE3148 übermittelt werden - [939] Format: Die Zeichenkette muss die Zeichen @ und ." - 43,Kommunikationsverbindung,SG3,COM,3155,,EM,,Elektronische Post,X [1P0..1], - 44,Kommunikationsverbindung,SG3,COM,3155,,FX,,Telefax,X [1P0..1], - 45,Kommunikationsverbindung,SG3,COM,3155,,TE,,Telefon,X [1P0..1], - 46,Kommunikationsverbindung,SG3,COM,3155,,AJ,,weiteres Telefon,X [1P0..1], - 47,Kommunikationsverbindung,SG3,COM,3155,,AL,,Handy,X [1P0..1], - 48,MP-ID Empfänger,SG2,,,,,,,Muss, - 49,MP-ID Empfänger,SG2,NAD,,,,,,Muss, - 50,MP-ID Empfänger,SG2,NAD,3035,,,,,MR, - 51,MP-ID Empfänger,SG2,NAD,3039,,,,MP-ID,X [1],[1] Nur MP-ID aus Sparte Strom - 52,MP-ID Empfänger,SG2,NAD,3055,,9,,GS1,X, - 53,MP-ID Empfänger,SG2,NAD,3055,,293,,"DE, BDEW (Bundesverbandder Energie- undWasserwirtschaft e.V.)",X, - 54,Abschnitts-Kontrollsegment,,UNS,,,,,,Muss, - 55,Abschnitts-Kontrollsegment,,UNS,0081,,Positionsteil,,,D, - 56,Name und Adresse des Unternehmens,SG4,,,,,,,Muss [10],[10] Wenn BGM DE1373 = 11 (Dokument nicht verfügbar) nicht vorhanden - 57,Name und Adresse des Unternehmens,SG4,NAD,,,,,,Muss, - 58,Name und Adresse des Unternehmens,SG4,NAD,3035,,,,,Z36, - 59,Name und Adresse des Unternehmens,SG4,NAD,3036,,,,Name,X [506],"[506] Hinweis: Das Datenelement ist so zu füllen, dass sein Inhalt den Vorgaben des USt.-Gesetzes genügt, so dass der Empfänger diese Daten in einer INVOIC nutzen kann." - 60,Name und Adresse des Unternehmens,SG4,NAD,3045,,Z02,,Struktur derFirmenbezeichnung,X, - 61,Name und Adresse des Unternehmens,SG4,NAD,3042,,,,Straße und Hausnummer oderPostfach,X [506],"[506] Hinweis: Das Datenelement ist so zu füllen, dass sein Inhalt den Vorgaben des USt.-Gesetzes genügt, so dass der Empfänger diese Daten in einer INVOIC nutzen kann." - 62,Name und Adresse des Unternehmens,SG4,NAD,3164,,,,Ort,X [506],"[506] Hinweis: Das Datenelement ist so zu füllen, dass sein Inhalt den Vorgaben des USt.-Gesetzes genügt, so dass der Empfänger diese Daten in einer INVOIC nutzen kann." - 63,Name und Adresse des Unternehmens,SG4,NAD,3251,,,,Postleitzahl,M [2] ∧ [506],[2] Wenn der Code im DE3207 in - 64,Name und Adresse des Unternehmens,SG4,NAD,3207,,,,"Ländername, Code",X [506],"[506] Hinweis: Das Datenelement ist so zu füllen, dass sein Inhalt den Vorgaben des USt.-Gesetzes genügt, so dass der Empfänger diese Daten in einer INVOIC nutzen kann." - 65,Bankverbindung,SG4,FII,,,,,,Muss, - 66,Bankverbindung,SG4,FII,3035,,,,,BK, - 67,Bankverbindung,SG4,FII,3194,,IBAN,,,X, - 68,Bankverbindung,SG4,FII,3192,,,,Name des Kontoinhabers,X, - 69,Bankverbindung,SG4,FII,3192,,,,Name des Kontoinhabers,K, - 70,Bankverbindung,SG4,FII,3433,,BIC,,,X, - 71,Bankverbindung,SG4,FII,3432,,,,Name des Kredinstituts,X, - 72,Internetseite (URL),SG4,FTX,,,,,,Muss, - 73,Internetseite (URL),SG4,FTX,4451,,,,,Z13, - 74,Internetseite (URL),SG4,FTX,4440,,,,Internetseite,X, - 75,Gericht und Handelsregister-Nummer,SG4,FTX,,,,,,Soll [3],[3] wenn vorhanden - 76,Gericht und Handelsregister-Nummer,SG4,FTX,4451,,Handelsregister-Nummer,,,Z15, - 77,Gericht und Handelsregister-Nummer,SG4,FTX,4440,,,,Gericht,X, - 78,Gericht und Handelsregister-Nummer,SG4,FTX,4440,,,,Handelsregister-Nummer,X, - 79,"Steuernummer, Umsatzsteuernummer",SG6,,,,,,,Muss, - 80,"Steuernummer, Umsatzsteuernummer",SG6,RFF,,,,,,Muss, - 81,"Steuernummer, Umsatzsteuernummer",SG6,RFF,1153,,VA,,Umsatzsteuernummer,X [2P0..1] ⊻ [3P1..1], - 82,"Steuernummer, Umsatzsteuernummer",SG6,RFF,1153,,FC,,Steuernummer,X [2P0..1], - 83,"Steuernummer, Umsatzsteuernummer",SG6,RFF,1154,,,,"Referenz, Identifikation",X, - 84,Faxnummer,SG6,RFF,,,,,,Kann, - 85,Faxnummer,SG6,RFF,1153,,Z25,,Faxnummer,X, - 86,Faxnummer,SG6,RFF,1154,,,,Faxnummer,X [940],[940] Format: Die Zeichenkette muss mit dem Zeichen + beginnen und danach dürfen nur noch Ziffern folgen - 87,Erreichbarkeit an Werktagen,SG12,,,,,,,Muss, - 88,Erreichbarkeit an Werktagen,SG12,CCI,,,,,,Muss, - 89,Erreichbarkeit an Werktagen,SG12,CCI,7059,,Unternehmens,,,Z40, - 90,Erreichbarkeit,SG12,DTM,,,,,,Muss, - 91,Erreichbarkeit,SG12,DTM,2005,,Z36,,Verfügbarkeit Montag,X [1P1..1], - 92,Erreichbarkeit,SG12,DTM,2005,,Z37,,Verfügbarkeit Dienstag,X [1P1..1], - 93,Erreichbarkeit,SG12,DTM,2005,,Z38,,Verfügbarkeit Mittwoch,X [1P1..1], - 94,Erreichbarkeit,SG12,DTM,2005,,Z39,,Verfügbarkeit Donnerstag,X [1P1..1], - 95,Erreichbarkeit,SG12,DTM,2005,,Z40,,Verfügbarkeit Freitag,X [1P1..1], - 96,Erreichbarkeit,SG12,DTM,2005,,Z41,,Mittagspause (= Ausschlussder Verfügbarkeit),X [1P0..1], - 97,Erreichbarkeit,SG12,DTM,2380,,,,"Datum oder Uhrzeit oderZeitspanne, Wert",X [503],[503] Hinweis: Angabe erfolgt in gesetzlicher deutscher Zeit - 98,Erreichbarkeit,SG12,DTM,2379,,501,,HHMMHHMM,X, - 99,Name und Anschrift Ansprechpartner Übertragungsweg / Datenaustausch,SG4,,,,,,,Muss [10],[10] Wenn BGM DE1373 = 11 (Dokument nicht verfügbar) nicht vorhanden - 100,Name und Anschrift Ansprechpartner Übertragungsweg / Datenaustausch,SG4,NAD,,,,,,Muss, - 101,Name und Anschrift Ansprechpartner Übertragungsweg / Datenaustausch,SG4,NAD,3035,,Übertragungsweg /Datenaustausch,,,Z10, - 102,Name und Anschrift Ansprechpartner Übertragungsweg / Datenaustausch,SG4,NAD,3036,,,,Name,X [500],[500] Hinweis: Es kann der Firmenname eines Dienstleisters oder die identische Firmenbezeichnung aus SG4 NAD+SU / DDM / DEB / Z31 / Z34 / Z35 / Z36 eingetragen werden. - 103,Name und Anschrift Ansprechpartner Übertragungsweg / Datenaustausch,SG4,NAD,3045,,Z02,,Struktur derFirmenbezeichnung,X, - 104,Name und Anschrift Ansprechpartner Übertragungsweg / Datenaustausch,SG4,NAD,3042,,,,Straße und Hausnummer oderPostfach,X, - 105,Name und Anschrift Ansprechpartner Übertragungsweg / Datenaustausch,SG4,NAD,3164,,,,Ort,X, - 106,Name und Anschrift Ansprechpartner Übertragungsweg / Datenaustausch,SG4,NAD,3251,,,,Postleitzahl,M [2]S [3],"[2] Wenn der Code im DE3207 in der ""EDI@Energy Codeliste der europäischen Ländercodes"" in der Spalte ""PLZ vorhanden"" ein ""X"" enthält" - 107,Name und Anschrift Ansprechpartner Übertragungsweg / Datenaustausch,SG4,NAD,3207,,,,"Ländername, Code",X, - 108,Ansprechpartner,SG7,,,,,,,Muss, - 109,Ansprechpartner,SG7,CTA,,,,,,Muss, - 110,Ansprechpartner,SG7,CTA,3139,,,,,IC, - 111,Ansprechpartner,SG7,CTA,3412,,,,Name der organisatorischen Einheit,X [501],"[501] Hinweis: Es darf kein Name einer natürlichen Person übermittelt werden, stattdessen ist die organisatorische Einheit im Unternehmen zu nennen." - 112,Kommunikationsverbindung,SG7,COM,,,,,,Muss, - 113,Kommunikationsverbindung,SG7,COM,3148,,,,Nummer / Adresse,X (([939][6]) ∨ ([940][8]))∧ [502],"[6] wenn im DE3155 im demselben COM der Code EM vorhanden ist - [8] wenn im DE3155 im demselben COM der Code TE / FX vorhanden ist - [502] Hinweis: Es darf nur eine Information im DE3148 übermittelt werden - [939] Format: Die Zeichenkette muss die Zeichen @ und . enthalten - [940] Format: Die Zeichenkette muss mit dem Zeichen + beginnen und danach dürfen nur noch Ziffern folgen" - 114,Kommunikationsverbindung,SG7,COM,3155,,EM,,Elektronische Post,X [1P1..1], - 115,Kommunikationsverbindung,SG7,COM,3155,,TE,,Telefon,X [1P1..1], - 116,Kommunikationsverbindung,SG7,COM,3155,,FX,,Telefax,X [1P0..1], - 117,Name und Anschrift Ansprechpartner Rahmenverträge,SG4,,,,,,,Muss [10],[10] Wenn BGM DE1373 = 11 (Dokument nicht verfügbar) nicht vorhanden - 118,Name und Anschrift Ansprechpartner Rahmenverträge,SG4,NAD,,,,,,Muss, - 119,Name und Anschrift Ansprechpartner Rahmenverträge,SG4,NAD,3035,,Rahmenverträge,,,Z11, - 120,Name und Anschrift Ansprechpartner Rahmenverträge,SG4,NAD,3036,,,,Name,X [500],[500] Hinweis: Es kann der Firmenname eines Dienstleisters oder die identische Firmenbezeichnung aus SG4 NAD+SU / DDM / DEB / Z31 / Z34 / Z35 / Z36 eingetragen werden. - 121,Name und Anschrift Ansprechpartner Rahmenverträge,SG4,NAD,3045,,Z02,,Struktur derFirmenbezeichnung,X, - 122,Name und Anschrift Ansprechpartner Rahmenverträge,SG4,NAD,3042,,,,Straße und Hausnummer oderPostfach,X, - 123,Name und Anschrift Ansprechpartner Rahmenverträge,SG4,NAD,3164,,,,Ort,X, - 124,Name und Anschrift Ansprechpartner Rahmenverträge,SG4,NAD,3251,,,,Postleitzahl,M [2]S [3],"[2] Wenn der Code im DE3207 in der ""EDI@Energy Codeliste der europäischen Ländercodes"" in der Spalte ""PLZ vorhanden"" ein ""X"" enthält - [3] wenn vorhanden" - 125,Name und Anschrift Ansprechpartner Rahmenverträge,SG4,NAD,3207,,,,"Ländername, Code",X, - 126,Ansprechpartner,SG7,,,,,,,Muss, - 127,Ansprechpartner,SG7,CTA,,,,,,Muss, - 128,Ansprechpartner,SG7,CTA,3139,,,,,IC, - 129,Ansprechpartner,SG7,CTA,3412,,,,Name der organisatorischen Einheit,X [501],"[501] Hinweis: Es darf kein Name einer natürlichen Person übermittelt werden, stattdessen ist die organisatorische Einheit im Unternehmen zu nennen." - 130,Kommunikationsverbindung,SG7,COM,,,,,,Muss, - 131,Kommunikationsverbindung,SG7,COM,3148,,,,Nummer / Adresse,X (([939][6]) ∨ ([940][8]))∧ [502],"[6] wenn im DE3155 im demselben COM der Code EM vorhanden ist - [8] wenn im DE3155 im demselben COM der Code TE / FX vorhanden ist - [502] Hinweis: Es darf nur eine Information im DE3148 übermittelt werden - [939] Format: Die Zeichenkette muss die Zeichen @ und . enthalten - [940] Format: Die Zeichenkette muss mit dem Zeichen + beginnen und danach dürfen nur noch Ziffern folgen" - 132,Kommunikationsverbindung,SG7,COM,3155,,EM,,Elektronische Post,X [1P1..1], - 133,Kommunikationsverbindung,SG7,COM,3155,,TE,,Telefon,X [1P1..1], - 134,Kommunikationsverbindung,SG7,COM,3155,,FX,,Telefax,X [1P0..1], - 135,Name und Anschrift Ansprechpartner Abrechnungsprozesse,SG4,,,,,,,Muss [10],[10] Wenn BGM DE1373 = 11 (Dokument nicht verfügbar) nicht - 136,Name und Anschrift Ansprechpartner Abrechnungsprozesse,SG4,NAD,,,,,,Muss, - 137,Name und Anschrift Ansprechpartner Abrechnungsprozesse,SG4,NAD,3035,,Abrechnungsprozesse,,,Z17, - 138,Name und Anschrift Ansprechpartner Abrechnungsprozesse,SG4,NAD,3036,,,,Name,X [500],[500] Hinweis: Es kann der Firmenname eines Dienstleisters oder die identische Firmenbezeichnung aus SG4 NAD+SU / DDM / DEB / Z31 / Z34 / Z35 / Z36 eingetragen werden. - 139,Name und Anschrift Ansprechpartner Abrechnungsprozesse,SG4,NAD,3045,,Z02,,Struktur derFirmenbezeichnung,X, - 140,Name und Anschrift Ansprechpartner Abrechnungsprozesse,SG4,NAD,3042,,,,Straße und Hausnummer oderPostfach,X, - 141,Name und Anschrift Ansprechpartner Abrechnungsprozesse,SG4,NAD,3164,,,,Ort,X, - 142,Name und Anschrift Ansprechpartner Abrechnungsprozesse,SG4,NAD,3251,,,,Postleitzahl,M [2]S [3],"[2] Wenn der Code im DE3207 in der ""EDI@Energy Codeliste der europäischen Ländercodes"" in der Spalte ""PLZ vorhanden"" ein ""X"" enthält - [3] wenn vorhanden" - 143,Name und Anschrift Ansprechpartner Abrechnungsprozesse,SG4,NAD,3207,,,,"Ländername, Code",X, - 144,Ansprechpartner,SG7,,,,,,,Muss, - 145,Ansprechpartner,SG7,CTA,,,,,,Muss, - 146,Ansprechpartner,SG7,CTA,3139,,,,,IC, - 147,Ansprechpartner,SG7,CTA,3412,,,,Name der organisatorischen Einheit,X [501],"[501] Hinweis: Es darf kein Name einer natürlichen Person übermittelt werden, stattdessen ist die organisatorische Einheit im Unternehmen zu nennen." - 148,Kommunikationsverbindung,SG7,COM,,,,,,Muss, - 149,Kommunikationsverbindung,SG7,COM,3148,,,,Nummer / Adresse,X (([939][6]) ∨ ([940][8]))∧ [502],"[6] wenn im DE3155 im demselben COM der Code EM vorhanden ist - [8] wenn im DE3155 im demselben COM der Code TE / FX vorhanden ist - [502] Hinweis: Es darf nur eine Information im DE3148 übermittelt werden - [939] Format: Die Zeichenkette muss die Zeichen @ und . enthalten - [940] Format: Die Zeichenkette muss mit dem Zeichen + beginnen" - 150,Kommunikationsverbindung,SG7,COM,3155,,EM,,Elektronische Post,X [1P1..1], - 151,Kommunikationsverbindung,SG7,COM,3155,,TE,,Telefon,X [1P1..1], - 152,Kommunikationsverbindung,SG7,COM,3155,,FX,,Telefax,X [1P0..1], - 153,Name und Anschrift Bewegungsdaten,SG4,,,,,,,Muss [10],[10] Wenn BGM DE1373 = 11 (Dokument nicht verfügbar) nicht vorhanden - 154,Name und Anschrift Bewegungsdaten,SG4,NAD,,,,,,Muss, - 155,Name und Anschrift Bewegungsdaten,SG4,NAD,3035,,Bewegungsdaten,,,Z19, - 156,Name und Anschrift Bewegungsdaten,SG4,NAD,3036,,,,Name,X [500],[500] Hinweis: Es kann der Firmenname eines Dienstleisters oder die identische Firmenbezeichnung aus SG4 NAD+SU / DDM / DEB / Z31 / Z34 / Z35 / Z36 eingetragen werden. - 157,Name und Anschrift Bewegungsdaten,SG4,NAD,3045,,Z02,,Struktur derFirmenbezeichnung,X, - 158,Name und Anschrift Bewegungsdaten,SG4,NAD,3042,,,,Straße und Hausnummer oderPostfach,X, - 159,Name und Anschrift Bewegungsdaten,SG4,NAD,3164,,,,Ort,X, - 160,Name und Anschrift Bewegungsdaten,SG4,NAD,3251,,,,Postleitzahl,M [2]S [3],"[2] Wenn der Code im DE3207 in der ""EDI@Energy Codeliste der europäischen Ländercodes"" in der Spalte ""PLZ vorhanden"" ein ""X"" enthält - [3] wenn vorhanden" - 161,Name und Anschrift Bewegungsdaten,SG4,NAD,3207,,,,"Ländername, Code",X, - 162,Ansprechpartner,SG7,,,,,,,Muss, - 163,Ansprechpartner,SG7,CTA,,,,,,Muss, - 164,Ansprechpartner,SG7,CTA,3139,,,,,IC, - 165,Ansprechpartner,SG7,CTA,3412,,,,Name der organisatorischen Einheit,X [501],"[501] Hinweis: Es darf kein Name einer natürlichen Person übermittelt werden, stattdessen ist die organisatorische Einheit im Unternehmen zu nennen." - 166,Kommunikationsverbindung,SG7,COM,,,,,,Muss, - 167,Kommunikationsverbindung,SG7,COM,3148,,,,Nummer / Adresse,X (([939][6]) ∨ ([940][8]))∧ [502],"[6] wenn im DE3155 im demselben COM der Code EM vorhanden ist - [8] wenn im DE3155 im demselben COM der Code TE / FX vorhanden ist " - 168,Kommunikationsverbindung,SG7,COM,3155,,EM,,Elektronische Post,X [1P1..1], - 169,Kommunikationsverbindung,SG7,COM,3155,,TE,,Telefon,X [1P1..1], - 170,Kommunikationsverbindung,SG7,COM,3155,,FX,,Telefax,X [1P0..1], - 171,Nachrichten-Endesegment,,UNT,,,,,,Muss, - 172,Nachrichten-Endesegment,,UNT,0074,,,,Anzahl der Segmente in einerNachricht,X, - 173,Nachrichten-Endesegment,,UNT,0062,,,,Nachrichten-Referenznummer,X, - - ''', - '37007.csv': ''' - ,Segmentname,Segmentgruppe,Segment,Datenelement,Segment ID,Code,Qualifier,Beschreibung,Bedingungsausdruck,Bedingung - 0,Nachrichten-Kopfsegment,,UNH,,,,,,Muss, - 1,Nachrichten-Kopfsegment,,UNH,0062,,,,Nachrichten-Referenznummer,X, - 2,Nachrichten-Kopfsegment,,UNH,0065,,PARTIN,,Partnerstammdaten,X, - 3,Nachrichten-Kopfsegment,,UNH,0052,,D,,Entwurfs-Version,X, - 4,Nachrichten-Kopfsegment,,UNH,0054,,20B,,Ausgabe 2020 - B,X, - 5,Nachrichten-Kopfsegment,,UNH,0051,,UN,,UN/CEFACT,X, - 6,Nachrichten-Kopfsegment,,UNH,0057,,1.0c,,Versionsnummer derzugrundeliegendenBDEW-Nachrichtenbeschreibung,X, - 7,Beginn der Nachricht,,BGM,,,,,,Muss, - 8,Beginn der Nachricht,,BGM,1001,,Z75,,Kommunikationsparameter,X, - 9,Beginn der Nachricht,,BGM,1004,,,,Dokumentennummer,X, - 10,Beginn der Nachricht,,BGM,1373,,,,,11,[9] Wenn die Kommunikationsdaten vom Absender nicht mehr aktiv sind. - 11,Nachrichtendatum,,DTM,,,,,,Muss, - 12,Nachrichtendatum,,DTM,2005,,137,,Dokumenten-/Nachrichtendatum/-zeit,X, - 13,Nachrichtendatum,,DTM,2380,,,,"Datum oder Uhrzeit oderZeitspanne, Wert",X [931][494],"[494] Das hier genannte Datum muss der Zeitpunkt sein, zu dem das Dokument erstellt wurde, oder ein Zeitpunkt, der davor liegt. - [931] Format: ZZZ = +00" - 14,Nachrichtendatum,,DTM,2379,,303,,CCYYMMDDHHMMZZZ,X, - 15,Prüfidentifikator,SG1,,,,,,,Muss, - 16,Prüfidentifikator,SG1,RFF,,,,,,Muss, - 17,Prüfidentifikator,SG1,RFF,1153,,Z13,,Prüfidentifikator,X, - 18,Prüfidentifikator,SG1,RFF,1154,,37007,,ÜbermittlungKommunikationsparameter,X, - 19,Versionsnummer,SG1,,,,,,,Muss, - 20,Versionsnummer,SG1,RFF,,,,,,Muss, - 21,Versionsnummer,SG1,RFF,1153,,AGK,,Anwendungsreferenznummer,X, - 22,Versionsnummer,SG1,RFF,1056,,,,Versionsnummer,X [908][505],"[505] Wenn eine Vorgängerversion (RFF+ACW) angegeben ist, so muss der Wert in diesem DE1056 mindestens um 1 höher sein, als der Wert aus DE1056 der Vorgängerversion (RFF+ACW). - [908] Format: Mögliche Werte: 1 bis n" - 23,Gültig Ab,SG1,DTM,,,,,,Soll [4],[4] Wenn Vorgängerversion vorhanden - 24,Gültig Ab,SG1,DTM,2005,,157,,"Gültigkeit, Beginndatum",X, - 25,Gültig Ab,SG1,DTM,2380,,,,"Datum oder Uhrzeit oderZeitspanne, Wert",X [UB1], - 26,Gültig Ab,SG1,DTM,2379,,303,,CCYYMMDDHHMMZZZ,X, - 27,Vorgängerversion,SG1,,,,,,,Soll [4],[4] Wenn Vorgängerversion vorhanden - 28,Vorgängerversion,SG1,RFF,,,,,,Muss, - 29,Vorgängerversion,SG1,RFF,1153,,ACW,,Referenznummer einervorangegangenenNachricht,X, - 30,Vorgängerversion,SG1,RFF,1056,,,,Versionsnummer,X [908],[908] Format: Mögliche Werte: 1 bis n - 31,MP-ID Absender,SG2,,,,,,,Muss, - 32,MP-ID Absender,SG2,NAD,,,,,,Muss, - 33,MP-ID Absender,SG2,NAD,3035,,Nachrichtenaussteller bzw.,,,MS, - 34,MP-ID Absender,SG2,NAD,3039,,,,MP-ID,X [1],[1] Nur MP-ID aus Sparte Strom - 35,MP-ID Absender,SG2,NAD,3055,,9,,GS1,X, - 36,MP-ID Absender,SG2,NAD,3055,,293,,"DE, BDEW (Bundesverbandder Energie- undWasserwirtschaft e.V.)",X, - 37,Ansprechpartner,SG3,,,,,,,Kann, - 38,Ansprechpartner,SG3,CTA,,,,,,Muss, - 39,Ansprechpartner,SG3,CTA,3139,,,,,IC, - 40,Ansprechpartner,SG3,CTA,3412,,,,Name vom Ansprechpartner,X, - 41,Kommunikationsverbindung,SG3,COM,,,,,,Muss, - 42,Kommunikationsverbindung,SG3,COM,3148,,,,Nummer / Adresse,X (([939][6]) ∨ ([940][7]))∧ [502],"[6] wenn im DE3155 im demselben COM der Code EM vorhanden ist - [7] wenn im DE3155 im demselben COM der Code TE / FX / AJ / AL vorhanden ist - [502] Hinweis: Es darf nur eine Information im DE3148 übermittelt werden - [939] Format: Die Zeichenkette muss die Zeichen @ und . enthalten - [940] Format: Die Zeichenkette muss mit dem Zeichen + beginnen und danach dürfen nur noch Ziffern folgen" - 43,Kommunikationsverbindung,SG3,COM,3155,,EM,,Elektronische Post,X [1P0..1], - 44,Kommunikationsverbindung,SG3,COM,3155,,FX,,Telefax,X [1P0..1], - 45,Kommunikationsverbindung,SG3,COM,3155,,TE,,Telefon,X [1P0..1], - 46,Kommunikationsverbindung,SG3,COM,3155,,AJ,,weiteres Telefon,X [1P0..1], - 47,Kommunikationsverbindung,SG3,COM,3155,,AL,,Handy,X [1P0..1], - 48,MP-ID Empfänger,SG2,,,,,,,Muss, - 49,MP-ID Empfänger,SG2,NAD,,,,,,Muss, - 50,MP-ID Empfänger,SG2,NAD,3035,,,,,MR, - 51,MP-ID Empfänger,SG2,NAD,3039,,,,MP-ID,X [1],[1] Nur MP-ID aus Sparte Strom - 52,MP-ID Empfänger,SG2,NAD,3055,,9,,GS1,X, - 53,MP-ID Empfänger,SG2,NAD,3055,,293,,"DE, BDEW (Bundesverbandder Energie- undWasserwirtschaft e.V.)",X, - 54,Abschnitts-Kontrollsegment,,UNS,,,,,,Muss, - 55,Abschnitts-Kontrollsegment,,UNS,0081,,Positionsteil,,,D, - 56,Name und Adresse des Unternehmens,SG4,,,,,,,Muss [10],[10] Wenn BGM DE1373 = 11 (Dokument nicht verfügbar) nicht vorhanden - 57,Name und Adresse des Unternehmens,SG4,NAD,,,,,,Muss, - 58,Name und Adresse des Unternehmens,SG4,NAD,3035,,,,,SUDDMDEBZ31Z34Z35Z36, - 59,Zertifikatsaussteller (Issuer),SG4,FTX,,,,,,Muss, - 60,Zertifikatsaussteller (Issuer),SG4,FTX,4451,,,,,Z24, - 61,Zertifikatsaussteller (Issuer),SG4,FTX,4440,,,,Zertifikatsaussteller,X, - 62,Zertifikatsnutzer (Subject),SG4,FTX,,,,,,Muss, - 63,Zertifikatsnutzer (Subject),SG4,FTX,4451,,,,,Z23, - 64,Zertifikatsnutzer (Subject),SG4,FTX,4440,,,,Zertifikatsnutzer,X, - 65,Nachrichten-Endesegment,,UNT,,,,,,Muss, - 66,Nachrichten-Endesegment,,UNT,0074,,,,Anzahl der Segmente in einerNachricht,X, - 67,Nachrichten-Endesegment,,UNT,0062,,,,Nachrichten-Referenznummer,X, - - ''', - }) +# name: TestCli.test_kohlrahbi_cli_with_valid_arguments[13002] + ''' + ,Segmentname,Segmentgruppe,Segment,Datenelement,Segment ID,Code,Qualifier,Beschreibung,Bedingungsausdruck,Bedingung + 0,Nutzdaten-Kopfsegment,,UNB,,00002,,,,Muss, + 1,Nutzdaten-Kopfsegment,,UNB,0001,00002,UNOC,,UN/ECE-Zeichensatz C,X, + 2,Nutzdaten-Kopfsegment,,UNB,0002,00002,3,,Version 3,X, + 3,Nutzdaten-Kopfsegment,,UNB,0004,00002,,,MP-ID Absender,X, + 4,Nutzdaten-Kopfsegment,,UNB,0007,00002,14,,GS1,X, + 5,Nutzdaten-Kopfsegment,,UNB,0007,,502,,"DE, DVGW Service &Consult GmbH",X, + 6,Nutzdaten-Kopfsegment,,UNB,0010,00002,,,MP-ID Empfänger,X, + 7,Nutzdaten-Kopfsegment,,UNB,0007,00002,14,,GS1,X, + 8,Nutzdaten-Kopfsegment,,UNB,0007,,502,,"DE, DVGW Service &Consult GmbH",X, + 9,Nutzdaten-Kopfsegment,,UNB,0017,00002,,,Datum der Erstellung,X, + 10,Nutzdaten-Kopfsegment,,UNB,0019,00002,,,Uhrzeit der Erstellung,X, + 11,Nutzdaten-Kopfsegment,,UNB,0020,00002,,,Datenaustauschreferenz,X [918],"[918] Format: Zeichen aus dem über UNOC definierten Zeichensatz, wobei von den Buchstaben nur Großbuchstaben erlaubt sind." + 12,Nutzdaten-Kopfsegment,,UNB,0026,00002,EM,,Energiemenge,, + 13,Nutzdaten-Kopfsegment,,UNB,0026,,VL,,"Verrechnungsliste,Zählerstand",X, + 14,Nachrichtenkopfsegment,,UNH,,00003,,,,Muss, + 15,Nachrichtenkopfsegment,,UNH,0062,00003,,,Nachrichten-Referenznummer,X, + 16,Nachrichtenkopfsegment,,UNH,0065,00003,MSCON,,Bericht über den,X, + 17,Nachrichtenkopfsegment,,UNH,0065,,S,,Verbrauch messbarerDienstleistungen,, + 18,Nachrichtenkopfsegment,,UNH,0052,00003,D,,Entwurfs-Version,X, + 19,Nachrichtenkopfsegment,,UNH,0054,00003,04B,,Ausgabe 2004 - B,X, + 20,Nachrichtenkopfsegment,,UNH,0051,00003,UN,,UN/CEFACT,X, + 21,Nachrichtenkopfsegment,,UNH,0057,00003,2.4c,,Versionsnummer derzugrundeliegendenBDEW-Nachrichtenbeschreibung,X, + 22,Beginn der Nachricht,,BGM,,00004,,,,Muss, + 23,Beginn der Nachricht,,BGM,1001,00004,7,,Prozessdatenbericht,X, + 24,Beginn der Nachricht,,BGM,1004,00004,,,Dokumentennummer,X, + 25,Beginn der Nachricht,,BGM,1225,00004,9,,Original,X, + 26,Nachrichtendatum,,DTM,,00005,,,,Muss, + 27,Nachrichtendatum,,DTM,2005,00005,137,,Dokumenten-/Nachrichtendatum/-zeit,X, + 28,Nachrichtendatum,,DTM,2380,00005,,,"Datum oder Uhrzeit oderZeitspanne, Wert",X [931] [494],"[494] Das hier genannte Datum muss der Zeitpunkt sein, zu dem das Dokument erstellt wurde, oder ein Zeitpunkt, der davor liegt. + [931] Format: ZZZ = +00" + 29,Nachrichtendatum,,DTM,2379,00005,303,,CCYYMMDDHHMMZZZ,X, + 30,Referenzangaben,SG1,,,,,,,Soll [1] ∧ [538],[1] Sofern per ORDERS + 31,Referenzangaben,SG1,RFF,,00006,,,,Muss, + 32,Referenzangaben,SG1,RFF,1153,00006,AGI,,Beantragungsnummer,X, + 33,Referenzangaben,SG1,RFF,1154,00006,,,"Referenz, Identifikation",X [529],"[509] Hinweis: Falls es sich um eine Korrekturenergiemenge handelt, ist hier die Referenz auf die MSCONS anzugeben, in der der Zählerstand vorab übermittelt wurde. + [529] Hinweis: Wert aus BGM+7 DE1004 der ORDERS mit der die Anforderung von Messwerten erfolgt ist. + [531] Hinweis: Wert aus BGM+7 DE1004 der MSCONS mit der der Zählerstand übermittelt wurde." + 34,Referenz auf vorherige Stammdatenmeldung des MSB,SG1,,,,,,,Soll [129] ∧[546],"[129] Wenn es sich um eine Ablesung aufgrund der Änderung an der Messtechnik oder deren Konfiguration handelt (z.B. Gerätewechsel). + [546] Hinweis: Eine Referenz auf die Stammdatenänderung des Gerätewechsels ist immer anzugeben, wenn diese dem Sender vorliegt." + 35,Referenz auf vorherige Stammdatenmeldung des MSB,SG1,RFF,,00008,,,,Muss, + 36,Referenz auf vorherige Stammdatenmeldung des MSB,SG1,RFF,1153,00008,Z30,,Referenz auf vorherigeStammdatenmeldungdes MSB,X, + 37,Referenz auf vorherige Stammdatenmeldung des MSB,SG1,RFF,1154,00008,,,"Referenz, Identifikation",X [530],[530] Hinweis: Wert aus SG4 IDE+24 DE7402 der UTILMD mit dem der Sender der MSCONS die vorherigen Stammdaten mittels UTILMD übermittelt hat. + 38,Prüfidentifikator,SG1,,,,,,,Muss, + 39,Prüfidentifikator,SG1,RFF,,00009,,,,Muss, + 40,Prüfidentifikator,SG1,RFF,1153,00009,Z13,,Prüfidentifikator,X, + 41,Prüfidentifikator,SG1,RFF,1154,00009,13002,,Messw. Zählerstand(Gas),X, + 42,Prüfidentifikator,SG1,RFF,1154,,13009,,Messwert Energiemenge(Gas),, + 43,MP-ID Absender,SG2,,,,,,,Muss, + 44,MP-ID Absender,SG2,NAD,,00010,,,,Muss, + 45,MP-ID Absender,SG2,NAD,3035,00010,MS,,Dokumenten-/Nachrichtenausstellerbzw. -absender,X, + 46,MP-ID Absender,SG2,NAD,3039,00010,,,MP-ID,X [118],[118] Nur MP-ID aus Sparte Gas + 47,MP-ID Absender,SG2,NAD,3055,00010,9,,GS1,X, + 48,MP-ID Absender,SG2,NAD,3055,,332,,"DE, DVGW Service &Consult GmbH",X, + 49,Ansprechpartner,SG4,,,,,,,Kann, + 50,Ansprechpartner,SG4,CTA,,00011,,,,Muss, + 51,Ansprechpartner,SG4,CTA,3139,00011,IC,,Informationsstelle,X, + 52,Ansprechpartner,SG4,CTA,3412,00011,,,Abteilung oder Bearbeiter,X, + 53,Kommunikationsverbindung,SG4,COM,,00012,,,,Muss, + 54,Kommunikationsverbindung,SG4,COM,3148,00012,,,"Kommunikationsadresse,Identifikation",X (([939] [142])∨ ([940] [143]))∧ [576],"[142] wenn im DE3155 im demselben COM der Code EM vorhanden ist + [143]  wenn im DE3155 im demselben COM der Code TE / FX / AJ / AL vorhanden ist + [576] Hinweis: Es darf nur eine Information im DE3148 übermittelt werden + [939] Format: Die Zeichenkette muss die Zeichen @ und . enthalten + [940] Format: Die Zeichenkette muss mit dem Zeichen + beginnen und danach dürfen nur noch Ziffern folgen" + 55,Kommunikationsverbindung,SG4,COM,3155,00012,TE,,Telefon,X [1P0..1], + 56,Kommunikationsverbindung,SG4,COM,3155,,EM,,E-Mail,X [1P0..1], + 57,Kommunikationsverbindung,SG4,COM,3155,,AJ,,weiteres Telefon,X [1P0..1], + 58,Kommunikationsverbindung,SG4,COM,3155,,AL,,Handy,X [1P0..1], + 59,Kommunikationsverbindung,SG4,COM,3155,,FX,,Telefax,X [1P0..1], + 60,MP-ID Empfänger,SG2,,,,,,,Muss, + 61,MP-ID Empfänger,SG2,NAD,,00013,,,,Muss, + 62,MP-ID Empfänger,SG2,NAD,3035,00013,MR,,Nachrichtenempfänger,X, + 63,MP-ID Empfänger,SG2,NAD,3039,00013,,,MP-ID,X [118],[118] Nur MP-ID aus Sparte Gas + 64,MP-ID Empfänger,SG2,NAD,3055,00013,9,,GS1,X, + 65,MP-ID Empfänger,SG2,NAD,3055,,332,,"DE, DVGW Service &Consult GmbH",X, + 66,Abschnitts-Kontrollsegment,,UNS,,00014,,,,Muss, + 67,Abschnitts-Kontrollsegment,,UNS,0081,00014,D,,Trennung von Kopf- undPositionsteil,X, + 68,Name und Adresse,SG5,,,,,,,Muss [2001],[2001] Segmentgruppe ist nur einmal je UNH anzugeben + 69,Name und Adresse,SG5,NAD,,00015,,,,Muss, + 70,Name und Adresse,SG5,NAD,3035,00015,DP,,Lieferanschrift,X, + 71,Identifikationsangabe,SG6,,,,,,,Muss, + 72,Identifikationsangabe,SG6,LOC,,00017,,,,Muss, + 73,Identifikationsangabe,SG6,LOC,3227,00017,172,,Meldepunkt,X, + 74,Identifikationsangabe,SG6,LOC,3225,00017,,,Bezeichnung,X [951] [510],"[510] Hinweis: Verwendung der ID der Messlokation + [514] Hinweis: Verwendung der ID der Marktlokation + [522] Hinweis: Nur für die Übermittlung der Korrekturenergiemengen im Zeitintervall zwischen zwei Messwerten. + [523] Hinweis: Nur für die Übermittlung der Energiemenge im Zeitintervall zwischen zwei Messwerten vor der Netznutzungsabrechnung. + [524] Hinweis: Nur, wenn es sich um die Übermittlung von Abrechnungsbrennwert und Z-Zahl für den vom Lieferanten über eine Geschäftsdatenanfrage angeforderten Zeitraum handelt. + [525] Hinweis: Nur für die Übermittlung der Energiemenge im Zeitintervall für eine Marktlokation ohne Messlokation (Pauschalanlage) wenn eines der Ereignisse aus Kapitel 4.2 eingetreten ist. + [950] Format: Marktlokations-ID + [951] Format: Zählpunktbezeichnung" + 75,Gerätenummer,SG7,,,,,,,Muss, + 76,Gerätenummer,SG7,RFF,,00023,,,,Muss, + 77,Gerätenummer,SG7,RFF,1153,00023,MG,,Gerätenummer,X, + 78,Gerätenummer,SG7,RFF,1154,00023,,,Gerätenummer,X, + 79,lfd. Position,SG9,,,,,,,Muss, + 80,lfd. Position,SG9,LIN,,00026,,,,Muss, + 81,lfd. Position,SG9,LIN,1082,00026,,,Positionsnummer,X [908],[908] Format: Mögliche Werte: 1 bis n + 82,Produktidentifikation,SG9,PIA,,00027,,,,Muss, + 83,Produktidentifikation,SG9,PIA,4347,00027,5,,Produktidentifikation,X, + 84,Produktidentifikation,SG9,PIA,7140,00027,,,Medium / OBIS-Kennzahl,X [501],"[51] Wenn SG9 PIA+5+7-0?: 33.86.0 vorhanden ist, darf mittels Wiederholung SG9 LIN in derselben Nachricht das SG9 PIA+5+7-0?:52.0.22/7- 0?:54.0.16/7-0?:54.0.20/7- 0?:54.0.22 nicht mehr angegeben werden + [501] Hinweis: Es sind nur die Werte erlaubt, die in der EDI@Energy Codeliste der OBIS-Kennzahlen und Medien mit dem entsprechenden Prüfidentifikator versehen sind." + 85,Produktidentifikation,SG9,PIA,7143,00027,SRW,,OBIS-Kennzahl,X, + 86,Mengenangaben,SG10,,,,,,,Muss, + 87,Mengenangaben,SG10,QTY,,00028,,,,Muss, + 88,Mengenangaben,SG10,QTY,6063,00028,220,,Wahrer Wert,X, + 89,Mengenangaben,SG10,QTY,6063,,67,,Ersatzwert,X [32], + 90,Mengenangaben,SG10,QTY,6063,,201,,Vorschlagswert,X [35] ∧ [36] ∧[12], + 91,Mengenangaben,SG10,QTY,6063,,20,,Nicht verwendbarer,X [35] ∧ [36] ∧Wert, + 92,Mengenangaben,SG10,QTY,6063,,187,,Prognosewert,, + 93,Mengenangaben,SG10,QTY,6063,,Z18,,Vorläufiger Wert,X [32] ∧ [12],"[11] Wenn SG9 PIA+5+7-0?: 52.0.22/7-0?:54.0.16/7-0?: 54.0.20/7-0?:54.0.22 + [12] Wenn nicht SG9 PIA+5+7-0?:52.0.22/7-0?:54. 0.16/7-0?:54.0.20/7-0?:54.0. 22 + [32] wenn MP-ID in SG2 NAD+MS in der Rolle NB + [33] wenn MP-ID in SG2 NAD+MR in der Rolle LF + [35] wenn MP-ID in SG2 NAD+MS in der Rolle MSB + [36] wenn MP-ID in SG2 NAD+MR in der Rolle NB + [42] Wenn MP-ID in SG2 NAD+MR in der Rolle MSB" + 94,Mengenangaben,SG10,QTY,6060,00028,,,Menge,X ([902] ∧ [906])∨ ([902] ∧ [907][48]),"[46] Wenn Wert in SG6 LOC+172 DE3225 genau 11 Stellen + [48] Wenn SG9 PIA+5+7-0?: 52.0.22 + [62] Wenn Wert in SG6 LOC+172 DE3225 genau 33 Stellen + [573] Hinweis: Eine Energiemenge in der Sparte Gas ist gemäß DVGW G685 Arbeitsblatt 4 Kapitel 5.3 auf ganze Kilowattstunden zu runden. + [902] Format: Möglicher Wert: ≥ 0 + [906] Format: max. 3" + 95,Beginn Messperiode,SG10,DTM,,00029,,,,Muss [11],[11] Wenn SG9 PIA+5+7-0?: 52.0.22/7-0?:54.0.16/7-0?: 54.0.20/7-0?:54.0.22 + 96,Beginn Messperiode,SG10,DTM,2005,00029,163,,"Verarbeitung,Beginndatum/-zeit",X, + 97,Beginn Messperiode,SG10,DTM,2380,00029,,,"Datum oder Uhrzeit oderZeitspanne, Wert",X [UB2],"[38] wenn in SG6 LOC+172 DE3225 die ID der Messlokation angegeben ist + [119] wenn in SG6 LOC+172 DE3225 die ID der Marktlokation angegeben ist + [495] Der Zeitpunkt muss ≤ dem Wert im DE2380 des DTM+137 sein + [931] Format: ZZZ = +00" + 98,Beginn Messperiode,SG10,DTM,2379,00029,303,,CCYYMMDDHHMMZZZ,X, + 99,Ende Messperiode,SG10,DTM,,00030,,,,Muss [11],[11] Wenn SG9 PIA+5+7-0?: 52.0.22/7-0?:54.0.16/7-0?: 54.0.20/7-0?:54.0.22 + 100,Ende Messperiode,SG10,DTM,2005,00030,164,,"Verarbeitung,Endedatum/-zeit",X, + 101,Ende Messperiode,SG10,DTM,2380,00030,,,"Datum oder Uhrzeit oderZeitspanne, Wert",X [UB2],"[38] wenn in SG6 LOC+172 DE3225 die ID der Messlokation angegeben ist + [119] wenn in SG6 LOC+172 DE3225 die ID der Marktlokation angegeben ist + [495] Der Zeitpunkt muss ≤ dem Wert im DE2380 des DTM+137 sein + [931] Format: ZZZ = +00" + 102,Ende Messperiode,SG10,DTM,2379,00030,303,,CCYYMMDDHHMMZZZ,X, + 103,Ablesedatum,SG10,DTM,,00031,,,,Soll [12] ∧ [93]∧ [128],"[12] Wenn nicht SG9 PIA+5+7-0?:52.0.22/7-0?:54. 0.16/7-0?:54.0.20/7-0?:54.0. 22 + [93] Wenn SG10 QTY DE6063 mit Wert 220 vorhanden + [128] Wenn es sich um eine Ablesung handelt, welche keine Ablesung aufgrund der Änderung an der Messtechnik oder deren Konfiguration ist (z.B. Kundenablesung)." + 104,Ablesedatum,SG10,DTM,2005,00031,9,,Bearbeitungs-/Verarbeitungsdatum/-zeit,X, + 105,Ablesedatum,SG10,DTM,2380,00031,,,"Datum oder Uhrzeit oderZeitspanne, Wert",X ([931] [111] ∧[495]) ⊻ ([134]∧ [135]) ,"[111] Wenn SG10 DTM+9 DE2379 in demselben Segment mit Wert 303 vorhanden + [134] Wenn SG10 DTM+9 DE2379 in demselben Segment mit Wert 102 vorhanden + [135] Der Wert an der Stelle CCYYMMDD muss ≤ dem Wert an der Stelle CCYYMMDD im DE2380 des DTM+137 sein + [495] Der Zeitpunkt muss ≤ dem Wert im DE2380 des DTM+137 sein + [931] Format: ZZZ = +00" + 106,Ablesedatum,SG10,DTM,2379,00031,102,,CCYYMMDD,X, + 107,Ablesedatum,SG10,DTM,2379,,303,,CCYYMMDDHHMMZZZ,X, + 108,Nutzungszeitpunkt,SG10,DTM,,00032,,,,Muss [12],[12] Wenn nicht SG9 PIA+5+7-0?:52.0.22/7-0?:54. 0.16/7-0?:54.0.20/7-0?:54.0. 22 + 109,Nutzungszeitpunkt,SG10,DTM,2005,00032,7,,Gültigkeitsdatum/-zeit,X, + 110,Nutzungszeitpunkt,SG10,DTM,2380,00032,,,"Datum oder Uhrzeit oderZeitspanne, Wert",X [UB2] ∧ [495]∧ ([130] ∨[133]),"[130] Wenn innerhalb desselben LIN-Segments neben diesem Segment (SG10 DTM+7 Nutzungszeitpunkt) noch das SG10 DTM+60 (Ausführungs- / Änderungszeitpunkt) oder das SG10 DTM+9 (Ablesedatum) vorhanden, darf der Wert der Differenz zwischen dem größeren und dem kleineren Zeitpunkt der DTM-Segmente ausschließlich < 24 Stunden sein. Findet zwischen den beiden Zeitpunkten die Sommer/Winter- Zeitumschaltung statt, darf der Wert der Differenz ausschließlich < 25 Stunden sein. Findet zwischen den beiden Zeitpunkten die Winter/Sommer- Zeitumschaltung statt, darf der Wert der Differenz ausschließlich < 23 Stunden sein. + [133] Wenn innerhalb desselben LIN-Segments neben diesem Segment (SG10 DTM+7 Nutzungszeitpunkt)" + 111,Nutzungszeitpunkt,SG10,DTM,2379,00032,303,,CCYYMMDDHHMMZZZ,X, + 112,Ausführungs- / Änderungszeitpunkt,SG10,DTM,,00033,,,,Soll [12] ∧ [129],"[12] Wenn nicht SG9 PIA+5+7-0?:52.0.22/7-0?:54. 0.16/7-0?:54.0.20/7-0?:54.0. 22 + [129] Wenn es sich um eine Ablesung aufgrund der Änderung an der Messtechnik oder deren Konfiguration handelt (z.B. Gerätewechsel)." + 113,Ausführungs- / Änderungszeitpunkt,SG10,DTM,2005,00033,60,,Konstruktionsänderungsdatum,X, + 114,Ausführungs- / Änderungszeitpunkt,SG10,DTM,2380,00033,,,"Datum oder Uhrzeit oderZeitspanne, Wert",X [931] [495],"[495] Der Zeitpunkt muss ≤ dem Wert im DE2380 des DTM+137 sein + [931] Format: ZZZ = +00" + 115,Ausführungs- / Änderungszeitpunkt,SG10,DTM,2379,00033,303,,CCYYMMDDHHMMZZZ,X, + 116,Plausibilisierungshinweis,SG10,STS,,00035,,,,Soll ([92] ⊻ [93]⊻ [94]) ∧ [126],"[92] Wenn SG10 QTY DE6063 mit Wert 67 vorhanden + [93] Wenn SG10 QTY DE6063 mit Wert 220 vorhanden + [94] Wenn SG10 QTY DE6063 mit Wert 201 vorhanden + [126] wenn Plausibilisierungshinweise vorliegen" + 117,Plausibilisierungshinweis,SG10,STS,9015,00035,Z33,,Plausibilisierungshinweis,X, + 118,Plausibilisierungshinweis,SG10,STS,9013,00035,Z83,,Kundenselbstablesung,X [5P0..1], + 119,Plausibilisierungshinweis,SG10,STS,9013,,Z84,,Leerstand,X [4P0..1] ⊻[5P0..1] ⊻[6P0..1] , + 120,Plausibilisierungshinweis,SG10,STS,9013,,Z85,,Realer Zählerüberlauf,X [4P0..1] ⊻geprüft[6P0..1] , + 121,Plausibilisierungshinweis,SG10,STS,9013,,Z86,,Plausibel wg.,X [4P0..1] ⊻Kontrollablesung[6P0..1] , + 122,Plausibilisierungshinweis,SG10,STS,9013,,Z87,,Plausibel wg.,X [4P0..1] ⊻, + 123,Ersatzwertbildungsverfahre n,SG10,STS,,00036,,,,Muss [92] ⊻ [94],"[92] Wenn SG10 QTY DE6063 mit Wert 67 vorhanden + [94] Wenn SG10 QTY DE6063 mit Wert 201 vorhanden" + 124,Ersatzwertbildungsverfahre n,SG10,STS,9015,00036,Z32,,Ersatzwertbildungsverfahren,X, + 125,Ersatzwertbildungsverfahre n,SG10,STS,9013,00036,Z89,,Vergleichsmessung,X [4P0..1] ⊻(nicht geeicht), + 126,Ersatzwertbildungsverfahre n,SG10,STS,9013,,Z90,,Messwertnachbildung,X [4P0..1] ⊻aus geeichten Werten, + 127,Ersatzwertbildungsverfahre n,SG10,STS,9013,,Z91,,MesswertnachbildungWerten,X [4P0..1] ⊻aus nicht geeichten, + 128,Ersatzwertbildungsverfahre n,SG10,STS,9013,,Z92,,Interpolation,X [4P0..1] ⊻[6P0..1], + 129,Ersatzwertbildungsverfahre n,SG10,STS,9013,,Z93,,Haltewert,X [4P0..1] ⊻[6P0..1], + 130,Ersatzwertbildungsverfahre n,SG10,STS,9013,,Z94,,Bilanzierung,X [4P0..1] ⊻Netzabschnitt, + 131,Ersatzwertbildungsverfahre n,SG10,STS,9013,,Z95,,Historische Messwerte,X [4P0..1] ⊻[6P0..1], + 132,Ersatzwertbildungsverfahre n,SG10,STS,9013,,ZQ8,,Aufteilung,X [4P0..1] ⊻[6P0..1], + 133,Ersatzwertbildungsverfahre n,SG10,STS,9013,,ZQ9,,Verwendung von WertenStörmengenzählwerks,X [4P0..1] ⊻des, + 134,Ersatzwertbildungsverfahre n,SG10,STS,9013,,ZR0,,Umgangs- und,X [4P0..1] ⊻Korrekturmengen, + 135,Ersatzwertbildungsverfahre n,SG10,STS,9013,,ZS0,,Ersatzwertbildungsverfahren gemäß Angaben aufEbene der Messlokation,,"[46] Wenn Wert in SG6 LOC+172 DE3225 genau 11 Stellen + [568] Hinweis: Verwendung ist nur zulässig, wenn es sich um 1:n Beziehung zwischen Markt- und Messlokation handelt und auf Ebene der Messlokation unterschiedliche Ersatzwertbildungsverfahren verwendet und kommuniziert wurden." + 136,Korrekturgrund,SG10,STS,,00037,,,,Soll [127] ∧[559],"[127] wenn ein Korrekturgrund anzugeben ist + [559] Hinweis: Ein Korrekturgrund ist anzugeben, wenn: 1. ein bereits an den MP übermittelter vorläufiger Wert nach Stornierung durch einen Ersatzwert ersetzt wird, oder 2. ein bereits an den MP übermittelter Ersatzwert nach Stornierung durch einen Ersatzwert ersetzt wird, oder 3. ein bereits an den MP übermittelter wahrer Wert" + 137,Korrekturgrund,SG10,STS,9015,00037,Z34,,Korrekturgrund,X, + 138,Korrekturgrund,SG10,STS,9013,00037,Z74,,kein Zugang,X [4P0..1] ⊻[6P0..1] ⊻[7P0..1] ⊻[8P0..1], + 139,Korrekturgrund,SG10,STS,9013,,Z75,,Kommunikationsstörung,X [4P0..1] ⊻[6P0..1] ⊻[7P0..1] ⊻[8P0..1], + 140,Korrekturgrund,SG10,STS,9013,,Z76,,Netzausfall,X [4P0..1] ⊻[6P0..1] ⊻[7P0..1] ⊻[8P0..1], + 141,Korrekturgrund,SG10,STS,9013,,Z78,,Gerätewechsel,X [4P0..1] ⊻[6P0..1] ⊻[7P0..1] ⊻[8P0..1], + 142,Korrekturgrund,SG10,STS,9013,,Z80,,Gerät arbeitet außerhalb,X [4P0..1] ⊻der Betriebsbedingungen[7P0..1] ⊻[8P0..1], + 143,Korrekturgrund,SG10,STS,9013,,Z81,,Messeinrichtung,X [4P0..1] ⊻gestört/defekt[7P0..1] ⊻[8P0..1], + 144,Korrekturgrund,SG10,STS,9013,,Z82,,Unsicherheit Messung,X [4P0..1] ⊻[6P0..1] ⊻[7P0..1] ⊻[8P0..1], + 145,Korrekturgrund,SG10,STS,9013,,Z98,,Berücksichtigung,X [4P0..1] ⊻Störmengenzählwerk, + 146,Korrekturgrund,SG10,STS,9013,,Z99,,Mengenumwertung,X [6P0..1] ⊻unvollständig[8P0..1], + 147,Korrekturgrund,SG10,STS,9013,,ZA0,,Uhrzeit gestellt /,X [4P0..1] ⊻Synchronisation[7P0..1] ⊻[8P0..1], + 148,Korrekturgrund,SG10,STS,9013,,ZA1,,Messwert unplausibel,X [6P0..1] ⊻[7P0..1] ⊻[8P0..1], + 149,Korrekturgrund,SG10,STS,9013,,ZA4,,Fehlerhafte Ablesung,X [4P0..1] ⊻[5P0..1] ⊻[6P0..1] ⊻[7P0..1] ⊻[8P0..1], + 150,Korrekturgrund,SG10,STS,9013,,ZA5,,Änderung der,X [4P0..1] ⊻Berechnung[6P0..1] ⊻[7P0..1] ⊻[8P0..1], + 151,Korrekturgrund,SG10,STS,9013,,ZA6,,Umbau der Messlokation,X [4P0..1] ⊻[5P0..1] ⊻, + 152,Grund der Ersatzwertbildung,SG10,STS,,00038,,,,Muss [92],[92] Wenn SG10 QTY DE6063 mit Wert 67 vorhanden + 153,Grund der Ersatzwertbildung,SG10,STS,9015,00038,Z40,,Grund derErsatzwertbildung,X, + 154,Grund der Ersatzwertbildung,SG10,STS,9013,00038,Z74,,kein Zugang,X [4P0..1], + 155,Grund der Ersatzwertbildung,SG10,STS,9013,,Z75,,Kommunikationsstörung,X [4P0..1], + 156,Grund der Ersatzwertbildung,SG10,STS,9013,,Z76,,Netzausfall,X [4P0..1], + 157,Grund der Ersatzwertbildung,SG10,STS,9013,,Z78,,Gerätewechsel,X [4P0..1], + 158,Grund der Ersatzwertbildung,SG10,STS,9013,,Z80,,Gerät arbeitet außerhalbder Betriebsbedingungen,X [4P0..1], + 159,Grund der Ersatzwertbildung,SG10,STS,9013,,Z81,,Messeinrichtung,X [4P0..1],"[46] Wenn Wert in SG6 LOC+172 DE3225 genau 11 Stellen + [570] Hinweis: Verwendung ist nur zulässig, wenn es sich um 1:n Beziehung zwischen Markt- und Messlokation" + 160,Gasqualität,SG10,STS,,00039,,,,Soll [97],[97] Wenn es sich um die Übermittlung eines Wertes aufgrund der Umstellung der Gasqualität handelt + 161,Gasqualität,SG10,STS,9015,00039,Z31,,Gasqualität,X, + 162,Gasqualität,SG10,STS,9013,00039,ZG3,,Umstellung Gasqualität,X, + 163,Nachrichten-Endesegment,,UNT,,00041,,,,Muss, + 164,Nachrichten-Endesegment,,UNT,0074,00041,,,Anzahl der Segmente in einerNachricht,X, + 165,Nachrichten-Endesegment,,UNT,0062,00041,,,Nachrichten-Referenznummer,X, + 166,Nutzdaten-Endesegment,,UNZ,,00042,,,,Muss, + 167,Nutzdaten-Endesegment,,UNZ,0036,00042,,,Datenaustauschzähler,X, + 168,Nutzdaten-Endesegment,,UNZ,0020,00042,,,Datenaustauschreferenz,X, + + ''' +# --- +# name: TestCli.test_kohlrahbi_cli_with_valid_arguments[13014] + ''' + ,Segmentname,Segmentgruppe,Segment,Datenelement,Segment ID,Code,Qualifier,Beschreibung,Bedingungsausdruck,Bedingung + 0,Nutzdaten-Kopfsegment,,UNB,,00002,,,,Muss, + 1,Nutzdaten-Kopfsegment,,UNB,0001,00002,UNOC,,UN/ECE-Zeichensatz C,X, + 2,Nutzdaten-Kopfsegment,,UNB,0002,00002,3,,Version 3,X, + 3,Nutzdaten-Kopfsegment,,UNB,0004,00002,,,MP-ID Absender,X, + 4,Nutzdaten-Kopfsegment,,UNB,0007,00002,14,,GS1,X, + 5,Nutzdaten-Kopfsegment,,UNB,0007,,500,,"DE, BDEW(Bundesverband derEnergie- undWasserwirtschaft e.V.)",X, + 6,Nutzdaten-Kopfsegment,,UNB,0007,,502,,"DE, DVGW Service &Consult GmbH",X, + 7,Nutzdaten-Kopfsegment,,UNB,0010,00002,,,MP-ID Empfänger,X, + 8,Nutzdaten-Kopfsegment,,UNB,0007,00002,14,,GS1,X, + 9,Nutzdaten-Kopfsegment,,UNB,0007,,500,,"DE, BDEW(Bundesverband derEnergie- undWasserwirtschaft e.V.)",X, + 10,Nutzdaten-Kopfsegment,,UNB,0007,,502,,"DE, DVGW Service &Consult GmbH",X, + 11,Nutzdaten-Kopfsegment,,UNB,0017,00002,,,Datum der Erstellung,X, + 12,Nutzdaten-Kopfsegment,,UNB,0019,00002,,,Uhrzeit der Erstellung,X, + 13,Nutzdaten-Kopfsegment,,UNB,0020,00002,,,Datenaustauschreferenz,X [918],"[918] Format: Zeichen aus dem über UNOC definierten Zeichensatz, wobei von den Buchstaben nur Großbuchstaben erlaubt sind." + 14,Nutzdaten-Kopfsegment,,UNB,0026,00002,EM,,Energiemenge,X, + 15,Nachrichtenkopfsegment,,UNH,,00003,,,,Muss, + 16,Nachrichtenkopfsegment,,UNH,0062,00003,,,Nachrichten-Referenznummer,X, + 17,Nachrichtenkopfsegment,,UNH,0065,00003,MSCON,,Bericht über den,X, + 18,Nachrichtenkopfsegment,,UNH,0065,,S,,Verbrauch messbarerDienstleistungen,, + 19,Nachrichtenkopfsegment,,UNH,0052,00003,D,,Entwurfs-Version,X, + 20,Nachrichtenkopfsegment,,UNH,0054,00003,04B,,Ausgabe 2004 - B,X, + 21,Nachrichtenkopfsegment,,UNH,0051,00003,UN,,UN/CEFACT,X, + 22,Nachrichtenkopfsegment,,UNH,0057,00003,2.4c,,Versionsnummer derzugrundeliegendenBDEW-Nachrichtenbeschreibung,X, + 23,Nachrichtenkopfsegment,,UNH,0068,00003,,,Allgemeine Zuordnungs-Referenz,,[22] Wenn Aufteilung vorhanden + 24,Nachrichtenkopfsegment,,UNH,0070,00003,,,Übermittlungsfolgenummer,, + 25,Nachrichtenkopfsegment,,UNH,0073,00003,C,,Beginn,, + 26,Nachrichtenkopfsegment,,UNH,0073,,F,,Ende,,"[23] Wenn UNH DE0070 mit 1 vorhanden + [24] Bei Aufteilung, in der Nachricht mit der höchsten Übermittlungsnummer" + 27,Beginn der Nachricht,,BGM,,00004,,,,Muss, + 28,Beginn der Nachricht,,BGM,1001,00004,Z23,,Bilanzierte Menge(MMMA),X, + 29,Beginn der Nachricht,,BGM,1001,,Z24,,Allokationsliste (MMMA),, + 30,Beginn der Nachricht,,BGM,1004,00004,,,Dokumentennummer,X, + 31,Beginn der Nachricht,,BGM,1225,00004,9,,Original,X, + 32,Nachrichtendatum,,DTM,,00005,,,,Muss, + 33,Nachrichtendatum,,DTM,2005,00005,137,,Dokumenten-/Nachrichtendatum/-zeit,X, + 34,Nachrichtendatum,,DTM,2380,00005,,,"Datum oder Uhrzeit oderZeitspanne, Wert",X [931] [494],"[494] Das hier genannte Datum muss der Zeitpunkt sein, zu dem das Dokument erstellt wurde, oder ein Zeitpunkt, der davor liegt. + [931] Format: ZZZ = +00" + 35,Nachrichtendatum,,DTM,2379,00005,303,,CCYYMMDDHHMMZZZ,X, + 36,Referenzangaben,SG1,,,,,,,Muss [81] ∧[36],"[36] wenn MP-ID in SG2 NAD+MR in der Rolle NB + [81] Wenn MP-ID in SG2 NAD+MS in der Rolle ÜNB" + 37,Referenzangaben,SG1,RFF,,00006,,,,Muss, + 38,Referenzangaben,SG1,RFF,1153,00006,AGI,,Beantragungsnummer,X, + 39,Referenzangaben,SG1,RFF,1154,00006,,,"Referenz, Identifikation",X [543],"[526] Hinweis: Wert aus BGM+Z24 DE1004 der ORDERS mit der die Allokationsliste bestellt wurde. + [543] Hinweis: Wert aus BGM+Z23 DE1004 der ORDERS mit der die bilanzierte Menge bestellt wurde." + 40,Versionsangabe marktlokationsscharfe Allokationsliste Gas (MMMA),SG1,DTM,,00007,,,,, + 41,Versionsangabe marktlokationsscharfe Allokationsliste Gas (MMMA),SG1,DTM,2005,00007,293,,Fertigstellungsdatum/-zeit,, + 42,Versionsangabe marktlokationsscharfe Allokationsliste Gas (MMMA),SG1,DTM,2380,00007,,,"Datum oder Uhrzeit oderZeitspanne, Wert",,[931] Format: ZZZ = +00 + 43,Versionsangabe marktlokationsscharfe Allokationsliste Gas (MMMA),SG1,DTM,2379,00007,304,,CCYYMMDDHHMMSSZZZ,, + 44,Prüfidentifikator,SG1,,,,,,,Muss, + 45,Prüfidentifikator,SG1,RFF,,00009,,,,Muss, + 46,Prüfidentifikator,SG1,RFF,1153,00009,Z13,,Prüfidentifikator,X, + 47,Prüfidentifikator,SG1,RFF,1154,00009,13013,,MarktlokationsscharfeAllokationsliste Gas(MMMA),, + 48,Prüfidentifikator,SG1,RFF,1154,,13014,,Marktlokationsscharfebilanzierte Menge (MMMA),X, + 49,MP-ID Absender,SG2,,,,,,,Muss, + 50,MP-ID Absender,SG2,NAD,,00010,,,,Muss, + 51,MP-ID Absender,SG2,NAD,3035,00010,MS,,Dokumenten-/Nachrichtenausstellerbzw. -absender,X, + 52,MP-ID Absender,SG2,NAD,3039,00010,,,MP-ID,X,[118] Nur MP-ID aus Sparte Gas + 53,MP-ID Absender,SG2,NAD,3055,00010,9,,GS1,X, + 54,MP-ID Absender,SG2,NAD,3055,,293,,"DE, BDEW(Bundesverband derEnergie- undWasserwirtschaft e.V.)",X, + 55,MP-ID Absender,SG2,NAD,3055,,332,,"DE, DVGW Service &Consult GmbH",X, + 56,Ansprechpartner,SG4,,,,,,,Kann, + 57,Ansprechpartner,SG4,CTA,,00011,,,,Muss, + 58,Ansprechpartner,SG4,CTA,3139,00011,IC,,Informationsstelle,X, + 59,Ansprechpartner,SG4,CTA,3412,00011,,,Abteilung oder Bearbeiter,X, + 60,Kommunikationsverbindung,SG4,COM,,00012,,,,Muss, + 61,Kommunikationsverbindung,SG4,COM,3148,00012,,,"Kommunikationsadresse,Identifikation",X (([939] [142])∨ ([940] [143]))∧ [576],"[142] wenn im DE3155 im demselben COM der Code EM vorhanden ist + [143]  wenn im DE3155 im demselben COM der Code TE / FX / AJ / AL vorhanden ist + [576] Hinweis: Es darf nur eine Information im DE3148 übermittelt werden + [939] Format: Die Zeichenkette muss die Zeichen @ und . enthalten + [940] Format: Die Zeichenkette muss mit dem Zeichen + beginnen und danach dürfen nur noch Ziffern folgen" + 62,Kommunikationsverbindung,SG4,COM,3155,00012,TE,,Telefon,X [1P0..1], + 63,Kommunikationsverbindung,SG4,COM,3155,,EM,,E-Mail,X [1P0..1], + 64,Kommunikationsverbindung,SG4,COM,3155,,AJ,,weiteres Telefon,X [1P0..1], + 65,Kommunikationsverbindung,SG4,COM,3155,,AL,,Handy,X [1P0..1], + 66,Kommunikationsverbindung,SG4,COM,3155,,FX,,Telefax,X [1P0..1], + 67,MP-ID Empfänger,SG2,,,,,,,Muss, + 68,MP-ID Empfänger,SG2,NAD,,00013,,,,Muss, + 69,MP-ID Empfänger,SG2,NAD,3035,00013,MR,,Nachrichtenempfänger,X, + 70,MP-ID Empfänger,SG2,NAD,3039,00013,,,MP-ID,X,[118] Nur MP-ID aus Sparte Gas + 71,MP-ID Empfänger,SG2,NAD,3055,00013,9,,GS1,X, + 72,MP-ID Empfänger,SG2,NAD,3055,,293,,"DE, BDEW",X, + 73,Abschnitts-Kontrollsegment,,UNS,,00014,,,,Muss, + 74,Abschnitts-Kontrollsegment,,UNS,0081,00014,D,,Trennung von Kopf- undPositionsteil,X, + 75,Name und Adresse,SG5,,,,,,,Muss [2001],[2001] Segmentgruppe ist nur einmal je UNH anzugeben + 76,Name und Adresse,SG5,NAD,,00015,,,,Muss, + 77,Name und Adresse,SG5,NAD,3035,00015,DP,,Lieferanschrift,X, + 78,Identifikationsangabe,SG6,,,,,,,Muss, + 79,Identifikationsangabe,SG6,LOC,,00017,,,,Muss, + 80,Identifikationsangabe,SG6,LOC,3227,00017,172,,Meldepunkt,X, + 81,Identifikationsangabe,SG6,LOC,3225,00017,,,Bezeichnung,X [950] [514],"[514] Hinweis: Verwendung der ID der Marktlokation + [950] Format: Marktlokations-ID" + 82,Bilanzierungsmonat,SG6,DTM,,00020,,,,, + 83,Bilanzierungsmonat,SG6,DTM,2005,00020,492,,"Bilanzierungsdatum, -zeit, -periode",, + 84,Bilanzierungsmonat,SG6,DTM,2380,00020,,,"Datum oder Uhrzeit oderZeitspanne, Wert",, + 85,Bilanzierungsmonat,SG6,DTM,2379,00020,610,,CCYYMM,, + 86,lfd. Position,SG9,,,,,,,Muss, + 87,lfd. Position,SG9,LIN,,00026,,,,Muss, + 88,lfd. Position,SG9,LIN,1082,00026,,,Positionsnummer,X [908],[908] Format: Mögliche Werte: 1 bis n + 89,Produktidentifikation,SG9,PIA,,00027,,,,Muss, + 90,Produktidentifikation,SG9,PIA,4347,00027,5,,Produktidentifikation,X, + 91,Produktidentifikation,SG9,PIA,7140,00027,,,Medium / OBIS-Kennzahl,X [501],"[501] Hinweis: Es sind nur die Werte erlaubt, die in der EDI@Energy Codeliste der OBIS-Kennzahlen und Medien mit dem entsprechenden Prüfidentifikator versehen sind." + 92,Produktidentifikation,SG9,PIA,7143,00027,Z02,,BDEW OBIS-ähnlicheKennzahl,X, + 93,Mengenangaben,SG10,,,,,,,Muss, + 94,Mengenangaben,SG10,QTY,,00028,,,,Muss, + 95,Mengenangaben,SG10,QTY,6063,00028,79,,"Energiemenge summiert(Summenwert,Bilanzsumme)",X, + 96,Mengenangaben,SG10,QTY,6060,00028,,,Menge,X [902] ∧ [906],"[902] Format: Möglicher Wert: ≥ 0 + [906] Format: max. 3 Nachkommastellen" + 97,Beginn Messperiode,SG10,DTM,,00029,,,,Muss, + 98,Beginn Messperiode,SG10,DTM,2005,00029,163,,"Verarbeitung,Beginndatum/-zeit",X, + 99,Beginn Messperiode,SG10,DTM,2380,00029,,,"Datum oder Uhrzeit oderZeitspanne, Wert",X [UB3] ∧ [495],[495] Der Zeitpunkt muss ≤ dem Wert im DE2380 des DTM+137 sein + 100,Beginn Messperiode,SG10,DTM,2379,00029,303,,CCYYMMDDHHMMZZZ,X, + 101,Ende Messperiode,SG10,DTM,,00030,,,,Muss, + 102,Ende Messperiode,SG10,DTM,2005,00030,164,,"Verarbeitung,Endedatum/-zeit",X, + 103,Ende Messperiode,SG10,DTM,2380,00030,,,"Datum oder Uhrzeit oderZeitspanne, Wert",X [UB3] ∧ [495],[495] Der Zeitpunkt muss ≤ dem Wert im DE2380 des DTM+137 sein + 104,Ende Messperiode,SG10,DTM,2379,00030,303,,CCYYMMDDHHMMZZZ,X, + 105,Leistungsperiode,SG10,DTM,,00034,,,,, + 106,Leistungsperiode,SG10,DTM,2005,00034,306,,Leistungsperiode,, + 107,Leistungsperiode,SG10,DTM,2380,00034,,,"Datum oder Uhrzeit oderZeitspanne, Wert",, + 108,Leistungsperiode,SG10,DTM,2379,00034,102,,CCYYMMDD,, + 109,Nachrichten-Endesegment,,UNT,,00041,,,,Muss, + 110,Nachrichten-Endesegment,,UNT,0074,00041,,,Anzahl der Segmente in einerNachricht,X, + 111,Nachrichten-Endesegment,,UNT,0062,00041,,,Nachrichten-Referenznummer,X, + 112,Nutzdaten-Endesegment,,UNZ,,00042,,,,Muss, + 113,Nutzdaten-Endesegment,,UNZ,0036,00042,,,Datenaustauschzähler,X, + 114,Nutzdaten-Endesegment,,UNZ,0020,00042,,,Datenaustauschreferenz,X, + + ''' +# --- +# name: TestCli.test_kohlrahbi_cli_with_valid_arguments[13023] + ''' + ,Segmentname,Segmentgruppe,Segment,Datenelement,Segment ID,Code,Qualifier,Beschreibung,Bedingungsausdruck,Bedingung + 0,Nutzdaten-Kopfsegment,,UNB,,00002,,,,Muss, + 1,Nutzdaten-Kopfsegment,,UNB,0001,00002,UNOC,,UN/ECE-Zeichensatz C,X, + 2,Nutzdaten-Kopfsegment,,UNB,0002,00002,3,,Version 3,X, + 3,Nutzdaten-Kopfsegment,,UNB,0004,00002,,,MP-ID Absender,X, + 4,Nutzdaten-Kopfsegment,,UNB,0007,00002,14,,GS1,X, + 5,Nutzdaten-Kopfsegment,,UNB,0007,,500,,"DE, BDEW(Bundesverband derEnergie- undWasserwirtschaft e.V.)",X, + 6,Nutzdaten-Kopfsegment,,UNB,0010,00002,,,MP-ID Empfänger,X, + 7,Nutzdaten-Kopfsegment,,UNB,0007,00002,14,,GS1,X, + 8,Nutzdaten-Kopfsegment,,UNB,0007,,500,,"DE, BDEW(Bundesverband derEnergie- undWasserwirtschaft e.V.)",X, + 9,Nutzdaten-Kopfsegment,,UNB,0017,00002,,,Datum der Erstellung,X, + 10,Nutzdaten-Kopfsegment,,UNB,0019,00002,,,Uhrzeit der Erstellung,X, + 11,Nutzdaten-Kopfsegment,,UNB,0020,00002,,,Datenaustauschreferenz,X [918],"[918] Format: Zeichen aus dem über UNOC definierten Zeichensatz, wobei von den Buchstaben nur Großbuchstaben erlaubt sind." + 12,Nutzdaten-Kopfsegment,,UNB,0026,00002,TL,,"Lastgang, beliebigerZeitraum",X, + 13,Nachrichtenkopfsegment,,UNH,,00003,,,,Muss, + 14,Nachrichtenkopfsegment,,UNH,0062,00003,,,Nachrichten-Referenznummer,X, + 15,Nachrichtenkopfsegment,,UNH,0065,00003,MSCON,,Bericht über den,X, + 16,Nachrichtenkopfsegment,,UNH,0065,,S,,Verbrauch messbarerDienstleistungen,, + 17,Nachrichtenkopfsegment,,UNH,0052,00003,D,,Entwurfs-Version,X, + 18,Nachrichtenkopfsegment,,UNH,0054,00003,04B,,Ausgabe 2004 - B,X, + 19,Nachrichtenkopfsegment,,UNH,0051,00003,UN,,UN/CEFACT,X, + 20,Nachrichtenkopfsegment,,UNH,0057,00003,2.4c,,Versionsnummer derzugrundeliegendenBDEW-Nachrichtenbeschreibung,X, + 21,Beginn der Nachricht,,BGM,,00004,,,,Muss, + 22,Beginn der Nachricht,,BGM,1001,00004,BK,,Zeitreihen im RahmenderBilanzkreisabrechnung,, + 23,Beginn der Nachricht,,BGM,1001,,Z39,,TäglicheSummenzeitreihe,, + 24,Beginn der Nachricht,,BGM,1001,,Z46,,RedispatchAusfallarbeitssummenzeitreihe,X, + 25,Beginn der Nachricht,,BGM,1004,00004,,,Dokumentennummer,X, + 26,Beginn der Nachricht,,BGM,1225,00004,9,,Original,X, + 27,Nachrichtendatum,,DTM,,00005,,,,Muss, + 28,Nachrichtendatum,,DTM,2005,00005,137,,Dokumenten-/Nachrichtendatum/-zeit,X, + 29,Nachrichtendatum,,DTM,2380,00005,,,"Datum oder Uhrzeit oderZeitspanne, Wert",X [931] [494],"[494] Das hier genannte Datum muss der Zeitpunkt sein, zu dem das Dokument erstellt wurde, oder ein Zeitpunkt, der davor liegt. + [931] Format: ZZZ = +00" + 30,Nachrichtendatum,,DTM,2379,00005,303,,CCYYMMDDHHMMZZZ,X, + 31,Prüfidentifikator,SG1,,,,,,,Muss, + 32,Prüfidentifikator,SG1,RFF,,00009,,,,Muss, + 33,Prüfidentifikator,SG1,RFF,1153,00009,Z13,,Prüfidentifikator,X, + 34,Prüfidentifikator,SG1,RFF,1154,00009,13003,,Summenzeitreihe,, + 35,Prüfidentifikator,SG1,RFF,1154,,13023,,RedispatchAusfallarbeitssummenzeitreihe,X, + 36,MP-ID Absender,SG2,,,,,,,Muss, + 37,MP-ID Absender,SG2,NAD,,00010,,,,Muss, + 38,MP-ID Absender,SG2,NAD,3035,00010,MS,,Dokumenten-/Nachrichtenausstellerbzw. -absender,X, + 39,MP-ID Absender,SG2,NAD,3039,00010,,,MP-ID,X [117],[117] Nur MP-ID aus Sparte Strom + 40,MP-ID Absender,SG2,NAD,3055,00010,9,,GS1,X, + 41,MP-ID Absender,SG2,NAD,3055,,293,,"DE, BDEW(Bundesverband derEnergie- undWasserwirtschaft e.V.)",X, + 42,Ansprechpartner,SG4,,,,,,,Kann, + 43,Ansprechpartner,SG4,CTA,,00011,,,,Muss, + 44,Ansprechpartner,SG4,CTA,3139,00011,IC,,Informationsstelle,X, + 45,Ansprechpartner,SG4,CTA,3412,00011,,,Abteilung oder Bearbeiter,X, + 46,Kommunikationsverbindung,SG4,COM,,00012,,,,Muss, + 47,Kommunikationsverbindung,SG4,COM,3148,00012,,,"Kommunikationsadresse,Identifikation",X (([939] [142])∨ ([940] [143]))∧ [576],"[142] wenn im DE3155 im demselben COM der Code EM vorhanden ist + [143]  wenn im DE3155 im demselben COM der Code TE / FX / AJ / AL vorhanden ist + [576] Hinweis: Es darf nur eine Information im DE3148 übermittelt werden + [939] Format: Die Zeichenkette muss die Zeichen @ und . enthalten + [940] Format: Die Zeichenkette muss mit dem Zeichen + beginnen und danach dürfen nur noch" + 48,Kommunikationsverbindung,SG4,COM,3155,00012,TE,,Telefon,X [1P0..1], + 49,Kommunikationsverbindung,SG4,COM,3155,,EM,,E-Mail,X [1P0..1], + 50,Kommunikationsverbindung,SG4,COM,3155,,AJ,,weiteres Telefon,X [1P0..1], + 51,Kommunikationsverbindung,SG4,COM,3155,,AL,,Handy,X [1P0..1], + 52,Kommunikationsverbindung,SG4,COM,3155,,FX,,Telefax,X [1P0..1], + 53,MP-ID Empfänger,SG2,,,,,,,Muss, + 54,MP-ID Empfänger,SG2,NAD,,00013,,,,Muss, + 55,MP-ID Empfänger,SG2,NAD,3035,00013,MR,,Nachrichtenempfänger,X, + 56,MP-ID Empfänger,SG2,NAD,3039,00013,,,MP-ID,X [117],[117] Nur MP-ID aus Sparte Strom + 57,MP-ID Empfänger,SG2,NAD,3055,00013,9,,GS1,X, + 58,MP-ID Empfänger,SG2,NAD,3055,,293,,"DE, BDEW(Bundesverband derEnergie- undWasserwirtschaft e.V.)",X, + 59,Abschnitts-Kontrollsegment,,UNS,,00014,,,,Muss, + 60,Abschnitts-Kontrollsegment,,UNS,0081,00014,D,,Trennung von Kopf- undPositionsteil,X, + 61,Name und Adresse,SG5,,,,,,,Muss [2001],[2001] Segmentgruppe ist nur einmal je UNH anzugeben + 62,Name und Adresse,SG5,NAD,,00015,,,,Muss, + 63,Name und Adresse,SG5,NAD,3035,00015,DP,,Lieferanschrift,X, + 64,Identifikationsangabe,SG6,,,,,,,Muss, + 65,Identifikationsangabe,SG6,LOC,,00017,,,,Muss, + 66,Identifikationsangabe,SG6,LOC,3227,00017,172,,Meldepunkt,X, + 67,Identifikationsangabe,SG6,LOC,3225,00017,,,Bezeichnung,X [951] [511],"[511] Hinweis: Verwendung der ID des MaBiS-ZP + [951] Format: Zählpunktbezeichnung" + 68,Bilanzierungsmonat,SG6,DTM,,00020,,,,Muss,[70] Wenn BGM+BK vorhanden + 69,Bilanzierungsmonat,SG6,DTM,2005,00020,492,,"Bilanzierungsdatum, -zeit, -periode",X, + 70,Bilanzierungsmonat,SG6,DTM,2380,00020,,,"Datum oder Uhrzeit oderZeitspanne, Wert",X, + 71,Bilanzierungsmonat,SG6,DTM,2379,00020,610,,CCYYMM,X, + 72,Versionsangabe ,SG6,DTM,,00021,,,,Muss,[70] Wenn BGM+BK vorhanden + 73,Versionsangabe ,SG6,DTM,2005,00021,293,,Fertigstellungsdatum/-zeit,X, + 74,Versionsangabe ,SG6,DTM,2380,00021,,,"Datum oder Uhrzeit oderZeitspanne, Wert",X [931],[931] Format: ZZZ = +00 + 75,Versionsangabe ,SG6,DTM,2379,00021,304,,CCYYMMDDHHMMSSZZZ,X, + 76,lfd. Position,SG9,,,,,,,Muss, + 77,lfd. Position,SG9,LIN,,00026,,,,Muss, + 78,lfd. Position,SG9,LIN,1082,00026,,,Positionsnummer,X [908],[908] Format: Mögliche Werte: 1 bis n + 79,Produktidentifikation,SG9,PIA,,00027,,,,Muss, + 80,Produktidentifikation,SG9,PIA,4347,00027,5,,Produktidentifikation,X, + 81,Produktidentifikation,SG9,PIA,7140,00027,,,Medium / OBIS-Kennzahl,X [501],"[501] Hinweis: Es sind nur die Werte erlaubt, die in der EDI@Energy Codeliste der OBIS-Kennzahlen und Medien mit dem entsprechenden Prüfidentifikator versehen sind." + 82,Produktidentifikation,SG9,PIA,7143,00027,SRW,,OBIS-Kennzahl,, + 83,Produktidentifikation,SG9,PIA,7143,,Z08,,Medium,X, + 84,Mengenangaben,SG10,,,,,,,Muss, + 85,Mengenangaben,SG10,QTY,,00028,,,,Muss, + 86,Mengenangaben,SG10,QTY,6063,00028,220,,Wahrer Wert,, + 87,Mengenangaben,SG10,QTY,6063,,67,,Ersatzwert,, + 88,Mengenangaben,SG10,QTY,6063,,79,,"Energiemenge summiert(Summenwert,Bilanzsumme)",X, + 89,Mengenangaben,SG10,QTY,6063,,Z18,,Vorläufiger Wert,, + 90,Mengenangaben,SG10,QTY,6063,,Z30,,Fehlender Wert,,"[70] Wenn BGM+BK vorhanden + [71] Wenn BGM+Z39 vorhanden" + 91,Mengenangaben,SG10,QTY,6060,00028,,,Menge,X [910] ∧ [906],"[902] Format: Möglicher Wert: ≥ 0 + [906] Format: max. 3 Nachkommastellen + [910] Format: Möglicher Wert: < 0 oder ≥ 0" + 92,Mengenangaben,SG10,QTY,6411,00028,KWH,,Kilowattstunde,X, + 93,Beginn Messperiode,SG10,DTM,,00029,,,,Muss, + 94,Beginn Messperiode,SG10,DTM,2005,00029,163,,"Verarbeitung,Beginndatum/-zeit",X, + 95,Beginn Messperiode,SG10,DTM,2380,00029,,,"Datum oder Uhrzeit oderZeitspanne, Wert",X [931] [495],"[495] Der Zeitpunkt muss ≤ dem Wert im DE2380 des DTM+137 sein + [931] Format: ZZZ = +00" + 96,Beginn Messperiode,SG10,DTM,2379,00029,303,,CCYYMMDDHHMMZZZ,X, + 97,Ende Messperiode,SG10,DTM,,00030,,,,Muss, + 98,Ende Messperiode,SG10,DTM,2005,00030,164,,"Verarbeitung,Endedatum/-zeit",X, + 99,Ende Messperiode,SG10,DTM,2380,00030,,,"Datum oder Uhrzeit oderZeitspanne, Wert",X [931] [495],[495] Der Zeitpunkt muss ≤ dem Wert im DE2380 des DTM+137 sein + 100,Ende Messperiode,SG10,DTM,2379,00030,303,,CCYYMMDDHHMMZZZ,X, + 101,Nachrichten-Endesegment,,UNT,,00041,,,,Muss, + 102,Nachrichten-Endesegment,,UNT,0074,00041,,,Anzahl der Segmente in einerNachricht,X, + 103,Nachrichten-Endesegment,,UNT,0062,00041,,,Nachrichten-Referenznummer,X, + 104,Nutzdaten-Endesegment,,UNZ,,00042,,,,Muss, + 105,Nutzdaten-Endesegment,,UNZ,0036,00042,,,Datenaustauschzähler,X, + 106,Nutzdaten-Endesegment,,UNZ,0020,00042,,,Datenaustauschreferenz,X, + + ''' +# --- +# name: TestCli.test_kohlrahbi_cli_with_valid_arguments[15002] + ''' + ,Segmentname,Segmentgruppe,Segment,Datenelement,Segment ID,Code,Qualifier,Beschreibung,Bedingungsausdruck,Bedingung + 0,Nachrichten-Kopfsegment,,UNH,,00001,,,,Muss, + 1,Nachrichten-Kopfsegment,,UNH,0062,00001,,,Nachrichten-Referenznummer,X, + 2,Nachrichten-Kopfsegment,,UNH,0065,00001,QUOTES,,Angebot,X, + 3,Nachrichten-Kopfsegment,,UNH,0052,00001,D,,Entwurfs-Version,X, + 4,Nachrichten-Kopfsegment,,UNH,0054,00001,10A,,Ausgabe 2010 - A,X, + 5,Nachrichten-Kopfsegment,,UNH,0051,00001,UN,,UN/CEFACT,X, + 6,Nachrichten-Kopfsegment,,UNH,0057,00001,1.3,,Versionsnummer derzugrundeliegendenBDEW-Nachrichtenbeschreibung,X, + 7,Beginn der Nachricht,,BGM,,00002,,,,Muss, + 8,Beginn der Nachricht,,BGM,1001,00002,Z29,,Abrechnung desMessstellenbetriebs vomMSB an den LF,X, + 9,Beginn der Nachricht,,BGM,1004,00002,,,Dokumentennummer,X, + 10,Nachrichtendatum,,DTM,,00003,,,,Muss, + 11,Nachrichtendatum,,DTM,2005,00003,137,,Dokumenten-/Nachrichtendatum/-zeit,X, + 12,Nachrichtendatum,,DTM,2380,00003,,,"Datum oder Uhrzeit oderZeitspanne, Wert",X [931] [494],"[494] Das hier genannte Datum muss der Zeitpunkt sein, zu dem das Dokument erstellt wurde, oder ein Zeitpunkt, der davor liegt. + [931] Format: ZZZ = +00" + 13,Nachrichtendatum,,DTM,2379,00003,303,,CCYYMMDDHHMMZZZ,X, + 14,Ausführungsdatum,,DTM,,00005,,,,Muss [27],[27] Wenn DTM+469 nicht vorhanden + 15,Ausführungsdatum,,DTM,2005,00005,203,,Ausführungsdatum/-zeit,X, + 16,Ausführungsdatum,,DTM,2380,00005,,,"Datum oder Uhrzeit oderZeitspanne, Wert",X [UB1], + 17,Ausführungsdatum,,DTM,2379,00005,303,,CCYYMMDDHHMMZZZ,X, + 18,Beginn zum (nächstmöglichen Termin),,DTM,,00006,,,,Soll [26] ∧ [28] ∧ [29],"[26] Wenn DTM+203 nicht vorhanden + [28] Wenn RFF+AAV vorhanden + [29] Wenn DTM+469 in Anfrage (REQOTE) vorhanden war" + 19,Beginn zum (nächstmöglichen Termin),,DTM,2005,00006,469,,"Startdatum oder -zeitpunkt, frühestes/r",X, + 20,Beginn zum (nächstmöglichen Termin),,DTM,2380,00006,,,"Datum oder Uhrzeit oderZeitspanne, Wert",X [UB1], + 21,Beginn zum (nächstmöglichen Termin),,DTM,2379,00006,303,,CCYYMMDDHHMMZZZ,X, + 22,Produkt-/ Leistungsbeschreibung,,IMD,,00009,,,,Muss, + 23,Produkt-/ Leistungsbeschreibung,,IMD,7081,00009,Z33,,Angebot auf BasisPreisblatt,X, + 24,Produkt-/ Leistungsbeschreibung,,IMD,7081,,Z34,,Individuelles Angebot,X, + 25,Nachrichtennummer der Anfrage,SG1,,,,,,,Soll [17],[17] Wenn das Angebot per REQOTE angefragt wurde + 26,Nachrichtennummer der Anfrage,SG1,RFF,,00011,,,,Muss, + 27,Nachrichtennummer der Anfrage,SG1,RFF,1153,00011,AAV,,Nummer der Anfrage,X, + 28,Nachrichtennummer der Anfrage,SG1,RFF,1154,00011,,,Nachrichtennummer,X [505],"[505] Hinweis: Wert aus BGM+Z29 DE1004 der REQOTE, mit der die Anfrage Rechnungsabwicklung erfolgt ist." + 29,Prüfidentifikator,SG1,,,,,,,Muss, + 30,Prüfidentifikator,SG1,RFF,,00012,,,,Muss, + 31,Prüfidentifikator,SG1,RFF,1153,00012,Z13,,Prüfidentifikator,X, + 32,Prüfidentifikator,SG1,RFF,1154,00012,15002,,AngebotRechnungsabwicklung MSBüber LF,X, + 33,Währungsangaben,SG4,,,,,,,Muss [21],[21] Wenn IMD++Z34 vorhanden + 34,Währungsangaben,SG4,CUX,,00013,,,,Muss, + 35,Währungsangaben,SG4,CUX,6347,00013,2,,Referenzwährung,X, + 36,Währungsangaben,SG4,CUX,6345,00013,EUR,,Euro,X, + 37,Währungsangaben,SG4,CUX,6343,00013,4,,Währung der Rechnung,X, + 38,MP-ID Absender,SG11,,,,,,,Muss, + 39,MP-ID Absender,SG11,NAD,,00014,,,,Muss, + 40,MP-ID Absender,SG11,NAD,3035,00014,Nachrichtenaussteller bzw.-absender,,,MS, + 41,MP-ID Absender,SG11,NAD,3039,00014,,,MP-ID,X [39],[39] MP-ID nur aus Sparte Strom + 42,MP-ID Absender,SG11,NAD,3055,00014,9,,GS1,X, + 43,MP-ID Absender,SG11,NAD,3055,,293,,"DE, BDEW (Bundesverbandder Energie- undWasserwirtschaft e.V.)",X, + 44,Ansprechpartner,SG14,,,,,,,Muss, + 45,Ansprechpartner,SG14,CTA,,00015,,,,Muss, + 46,Ansprechpartner,SG14,CTA,3139,00015,,,,IC, + 47,Ansprechpartner,SG14,CTA,3412,00015,,,Kontakt,X, + 48,Kommunikationsverbindung,SG14,COM,,00016,,,,Muss, + 49,Kommunikationsverbindung,SG14,COM,3148,00016,,,"Kommunikationsadresse,Identifikation",X, + 50,Kommunikationsverbindung,SG14,COM,3155,00016,EM,,Elektronische Post,X [1P0..1], + 51,Kommunikationsverbindung,SG14,COM,3155,,FX,,Telefax,X [1P0..1], + 52,MP-ID Empfänger,SG11,,,,,,,Muss, + 53,MP-ID Empfänger,SG11,NAD,,00017,,,,Muss, + 54,MP-ID Empfänger,SG11,NAD,3035,00017,,,,MR, + 55,MP-ID Empfänger,SG11,NAD,3039,00017,,,MP-ID,X [39],[39] MP-ID nur aus Sparte Strom + 56,MP-ID Empfänger,SG11,NAD,3055,00017,9,,GS1,X, + 57,MP-ID Empfänger,SG11,NAD,3055,,293,,"DE, BDEW (Bundesverbandder Energie- undWasserwirtschaft e.V.)",X, + 58,"Liefer-, bzw. Bezugsort",SG11,,,,,,,Muss, + 59,"Liefer-, bzw. Bezugsort",SG11,NAD,,00018,,,,Muss, + 60,"Liefer-, bzw. Bezugsort",SG11,NAD,3035,00018,,,,DP, + 61,Meldepunkt,SG11,LOC,,00019,,,,Muss, + 62,Meldepunkt,SG11,LOC,3227,00019,,,,172, + 63,Meldepunkt,SG11,LOC,3225,00019,,,Identifikator,X [950] [501],"[501] Hinweis: Verwendung der ID der Marktlokation + [950] Format: Marktlokations-ID" + 64,Positionsdaten,SG27,,,,,,,Muss, + 65,Positionsdaten,SG27,LIN,,00020,,,,Muss, + 66,Positionsdaten,SG27,LIN,1082,00020,,,Positionsnummer,X [911],"[911] Format: Mögliche Werte: 1 bis n, je Nachricht oder Segmentgruppe bei 1 beginnend und fortlaufend aufsteigend" + 67,Positionsdaten,SG27,LIN,7140,00020,,,Produkt-/Leistungsnummer,X ([31] ∧ ([65] ⊻ [66])) ⊻([942] [69] ∧ ([67] ⊻ [68])),"[31] Es sind nur die Artikelnummern erlaubt, die in der Codeliste der Artikelnummern des BDEW mit dem entsprechenden Prüfidentifikator versehen sind. + [65] Wenn DTM+203 (Ausführungsdatum) im DE2380 < 202312312300?+00 + [66] Wenn DTM+469 (Beginn zum (nächstmöglichen Termin)) im DE2380 < 202312312300?+00 + [67] Wenn DTM+203 (Ausführungsdatum) im DE2380 ≥ 202312312300?+00 + [68] Wenn DTM+469 (Beginn zum (nächstmöglichen Termin)) im DE2380 ≥ 202312312300?+00 + [69] Es sind nur Werte aus der EDI@Energy Codeliste der Artikelnummern und Artikel-ID erlaubt, die im Kapitel 3.5" + 68,Positionsdaten,SG27,LIN,7143,00020,Z01,,Artikelnummer,X [65] ⊻ [66], + 69,Positionsdaten,SG27,LIN,7143,,Z09,,Artikel-ID,X [67] ⊻ [68],"[65] Wenn DTM+203 (Ausführungsdatum) im DE2380 < 202312312300?+00 + [66] Wenn DTM+469 (Beginn zum (nächstmöglichen Termin)) im DE2380 < 202312312300?+00 + [67] Wenn DTM+203 (Ausführungsdatum) im DE2380 ≥ 202312312300?+00 + [68] Wenn DTM+469 (Beginn zum (nächstmöglichen Termin)) im DE2380 ≥ 202312312300?+00" + 70,Zusätzliche Produktidentifikation,SG27,PIA,,00021,,,,Muss [20] ∧ ([65] ⊻ [66]),"[20] Wenn IMD++Z33 vorhanden + [65] Wenn DTM+203 (Ausführungsdatum) im DE2380 < 202312312300?+00 + [66] Wenn DTM+469 (Beginn zum (nächstmöglichen Termin)) im DE2380 < 202312312300?+00" + 71,Zusätzliche Produktidentifikation,SG27,PIA,4347,00021,,,,1, + 72,Zusätzliche Produktidentifikation,SG27,PIA,7140,00021,,,Preisschlüsselstamm,X, + 73,Zusätzliche Produktidentifikation,SG27,PIA,7143,00021,Z06,,Preisschlüsselstamm,X, + 74,Menge,SG27,QTY,,00023,,,,Muss, + 75,Menge,SG27,QTY,6063,00023,47,,Berechnete (fakturierte)Menge,X, + 76,Menge,SG27,QTY,6060,00023,,,Menge,X [908],[908] Format: Mögliche Werte: 1 bis n + 77,Menge,SG27,QTY,6411,00023,H87,,Stück,X, + 78,zeitliche Mengenangaben,SG27,QTY,,00024,,,,Muss [21],[21] Wenn IMD++Z34 vorhanden + 79,zeitliche Mengenangaben,SG27,QTY,6063,00024,136,,Erreichte Menge in demZeitintervall,X, + 80,zeitliche Mengenangaben,SG27,QTY,6060,00024,,,Menge,X [908],[908] Format: Mögliche Werte: 1 bis n + 81,zeitliche Mengenangaben,SG27,QTY,6411,00024,ANN,,Jahr,X, + 82,zeitliche Mengenangaben,SG27,QTY,6411,,DAY,,Tag,X, + 83,zeitliche Mengenangaben,SG27,QTY,6411,,MON,,Monat,X, + 84,Geldbetrag,SG29,,,,,,,Muss [21],[21] Wenn IMD++Z34 vorhanden + 85,Geldbetrag,SG29,MOA,,00048,,,,Muss, + 86,Geldbetrag,SG29,MOA,5025,00048,203,,Positionsbetrag (ohne USt.),X, + 87,Geldbetrag,SG29,MOA,5004,00048,,,Geldbetrag,X [930],[930] Format: max. 2 Nachkommastellen + 88,Preisangaben,SG31,,,,,,,Muss [21],[21] Wenn IMD++Z34 vorhanden + 89,Preisangaben,SG31,PRI,,00049,,,,Muss, + 90,Preisangaben,SG31,PRI,5125,00049,CAL,,Berechnungspreis,X, + 91,Preisangaben,SG31,PRI,5118,00049,,,"Preis, Betrag",X [912],[912] Format: max. 6 Nachkommastellen + 92,Referenz auf ID weiterer Marktlokationen,SG32,,,,,,,Soll [18] ∧ [20],"[18] Wenn Angebot mehrere Marktlokationen abdeckt (AN nutzt mehrere Marktlokationen in einem Gebäude) + [20] Wenn IMD++Z33 vorhanden" + 93,Referenz auf ID weiterer Marktlokationen,SG32,RFF,,00051,,,,Muss, + 94,Referenz auf ID weiterer Marktlokationen,SG32,RFF,1153,00051,Z18,,Marktlokation,X, + 95,Referenz auf ID weiterer Marktlokationen,SG32,RFF,1154,00051,,,ID einer Marktlokation,X [950],[950] Format: Marktlokations-ID + 96,Abschnitts-Kontrollsegment,,UNS,,00097,,,,Muss, + 97,Abschnitts-Kontrollsegment,,UNS,0081,00097,und Summenteil,,,S, + 98,Summenbetrag (netto),,MOA,,00098,,,,Muss [21],[21] Wenn IMD++Z34 vorhanden + 99,Summenbetrag (netto),,MOA,5025,00098,97,,Gesamtbetrag desAngebots,X, + 100,Summenbetrag (netto),,MOA,5004,00098,,,Geldbetrag,X [930],[930] Format: max. 2 Nachkommastellen + 101,Nachrichten-Endesegment,,UNT,,00099,,,,Muss, + 102,Nachrichten-Endesegment,,UNT,0074,00099,,,Anzahl der Segmente in einerNachricht,X, + 103,Nachrichten-Endesegment,,UNT,0062,00099,,,Nachrichten-Referenznummer,X, + + ''' +# --- +# name: TestCli.test_kohlrahbi_cli_with_valid_arguments[17002] + ''' + ,Segmentname,Segmentgruppe,Segment,Datenelement,Segment ID,Code,Qualifier,Beschreibung,Bedingungsausdruck,Bedingung + 0,Nachrichten-Kopfsegment,,UNH,,00001,,,,Muss, + 1,Nachrichten-Kopfsegment,,UNH,0062,00001,,,Nachrichten-Referenznummer,X, + 2,Nachrichten-Kopfsegment,,UNH,0065,00001,ORDERS,,Bestellung,X, + 3,Nachrichten-Kopfsegment,,UNH,0052,00001,D,,Entwurfs-Version,X, + 4,Nachrichten-Kopfsegment,,UNH,0054,00001,09B,,Ausgabe 2009 - B,X, + 5,Nachrichten-Kopfsegment,,UNH,0051,00001,UN,,UN/CEFACT,X, + 6,Nachrichten-Kopfsegment,,UNH,0057,00001,1.3,,Versionsnummer derzugrundeliegendenBDEW-Nachrichtenbeschreibung,X, + 7,Beginn der Nachricht,,BGM,,00002,,,,Muss, + 8,Beginn der Nachricht,,BGM,1001,00002,Z11,,Weiterverpflichtung zumBetrieb der Messlokation,X, + 9,Beginn der Nachricht,,BGM,1004,00002,,,Dokumentennummer,X, + 10,Nachrichtendatum,,DTM,,00003,,,,Muss, + 11,Nachrichtendatum,,DTM,2005,00003,137,,Dokumenten-/Nachrichtendatum/-zeit,X, + 12,Nachrichtendatum,,DTM,2380,00003,,,"Datum oder Uhrzeit oderZeitspanne, Wert",X [931] [494],"[494] Das hier genannte Datum muss der Zeitpunkt sein, zu dem das Dokument erstellt wurde, oder ein Zeitpunkt, der davor liegt. + [931] Format: ZZZ = +00" + 13,Nachrichtendatum,,DTM,2379,00003,303,,CCYYMMDDHHMMZZZ,X, + 14,verschobener Abmeldetermin,,DTM,,00005,,,,Muss, + 15,verschobener Abmeldetermin,,DTM,2005,00005,Z02,,VerschobenerAbmeldetermin,X, + 16,verschobener Abmeldetermin,,DTM,2380,00005,,,"Datum oder Uhrzeit oderZeitspanne, Wert",X [UB3] ∧ [506],"[506] Hinweis: Datum, bis zu dem der MSBA zur Fortführung verpflichtet wird" + 17,verschobener Abmeldetermin,,DTM,2379,00005,303,,CCYYMMDDHHMMZZZ,X, + 18,Prüfidentifikator,SG1,,,,,,,Muss, + 19,Prüfidentifikator,SG1,RFF,,00019,,,,Muss, + 20,Prüfidentifikator,SG1,RFF,1153,00019,Z13,,Prüfidentifikator,X, + 21,Prüfidentifikator,SG1,RFF,1154,00019,17002,,Weiterverpflichtung MSBA,X, + 22,MP-ID Absender,SG2,,,,,,,Muss, + 23,MP-ID Absender,SG2,NAD,,00020,,,,Muss, + 24,MP-ID Absender,SG2,NAD,3035,00020,Nachrichtenaussteller bzw.-absender,,,MS, + 25,MP-ID Absender,SG2,NAD,3039,00020,,,MP-ID,X, + 26,MP-ID Absender,SG2,NAD,3055,00020,9,,GS1,X, + 27,MP-ID Absender,SG2,NAD,3055,,293,,"DE, BDEW (Bundesverbandder Energie- undWasserwirtschaft e.V.)",X, + 28,Ansprechpartner,SG5,,,,,,,Kann, + 29,Ansprechpartner,SG5,CTA,,00021,,,,Muss, + 30,Ansprechpartner,SG5,CTA,3139,00021,,,,IC, + 31,Ansprechpartner,SG5,CTA,3412,00021,,,Kontakt,X, + 32,Kommunikationsverbindung,SG5,COM,,00022,,,,Muss, + 33,Kommunikationsverbindung,SG5,COM,3148,00022,,,"Kommunikationsadresse,Identifikation",X, + 34,Kommunikationsverbindung,SG5,COM,3155,00022,EM,,Elektronische Post,X [1P0..1], + 35,Kommunikationsverbindung,SG5,COM,3155,,FX,,Telefax,X [1P0..1], + 36,Kommunikationsverbindung,SG5,COM,3155,,TE,,Telefon,X [1P0..1], + 37,Kommunikationsverbindung,SG5,COM,3155,,AJ,,weiteres Telefon,X [1P0..1], + 38,Kommunikationsverbindung,SG5,COM,3155,,AL,,Handy,X [1P0..1], + 39,MP-ID Empfänger,SG2,,,,,,,Muss, + 40,MP-ID Empfänger,SG2,NAD,,00023,,,,Muss, + 41,MP-ID Empfänger,SG2,NAD,3035,00023,,,,MR, + 42,MP-ID Empfänger,SG2,NAD,3039,00023,,,MP-ID,X, + 43,MP-ID Empfänger,SG2,NAD,3055,00023,9,,GS1,X, + 44,MP-ID Empfänger,SG2,NAD,3055,,293,,"DE, BDEW (Bundesverbandder Energie- undWasserwirtschaft e.V.)",X, + 45,MP-ID Empfänger,SG2,NAD,3055,,332,,"DE, DVGW Service &Consult GmbH",X, + 46,Meldepunkt,SG2,,,,,,,Muss, + 47,Meldepunkt,SG2,NAD,,00025,,,,Muss, + 48,Meldepunkt,SG2,NAD,3035,00025,,,,DP, + 49,Meldepunkt,SG2,LOC,,00026,,,,Muss, + 50,Meldepunkt,SG2,LOC,3227,00026,,,,172, + 51,Meldepunkt,SG2,LOC,3225,00026,,,Identifikator,X [951] [522],"[522] Hinweis: Verwendung der ID der Messlokation + [951] Format: Zählpunktbezeichnung" + 52,Referenz auf ID der Marktlokation,SG3,,,,,,,Muss [492],[492] Wenn MP-ID in NAD+MR (Nachrichtenempfänger) aus Sparte Strom + 53,Referenz auf ID der Marktlokation,SG3,RFF,,00027,,,,Muss, + 54,Referenz auf ID der Marktlokation,SG3,RFF,1153,00027,Z18,,Marktlokation,X, + 55,Referenz auf ID der Marktlokation,SG3,RFF,1154,00027,,,ID der Marktlokation,X [950],[950] Format: Marktlokations-ID + 56,Abschnitts-Kontrollsegment,,UNS,,00123,,,,Muss, + 57,Abschnitts-Kontrollsegment,,UNS,0081,00123,und Summenteil,,,S, + 58,Nachrichten-Endesegment,,UNT,,00125,,,,Muss, + 59,Nachrichten-Endesegment,,UNT,0074,00125,,,Anzahl der Segmente in einerNachricht,X, + 60,Nachrichten-Endesegment,,UNT,0062,00125,,,Nachrichten-Referenznummer,X, + + ''' +# --- +# name: TestCli.test_kohlrahbi_cli_with_valid_arguments[17010] + ''' + ,Segmentname,Segmentgruppe,Segment,Datenelement,Segment ID,Code,Qualifier,Beschreibung,Bedingungsausdruck,Bedingung + 0,Nachrichten-Kopfsegment,,UNH,,00001,,,,Muss, + 1,Nachrichten-Kopfsegment,,UNH,0062,00001,,,Nachrichten-Referenznummer,X, + 2,Nachrichten-Kopfsegment,,UNH,0065,00001,ORDERS,,Bestellung,X, + 3,Nachrichten-Kopfsegment,,UNH,0052,00001,D,,Entwurfs-Version,X, + 4,Nachrichten-Kopfsegment,,UNH,0054,00001,09B,,Ausgabe 2009 - B,X, + 5,Nachrichten-Kopfsegment,,UNH,0051,00001,UN,,UN/CEFACT,X, + 6,Nachrichten-Kopfsegment,,UNH,0057,00001,1.3,,Versionsnummer derzugrundeliegendenBDEW-Nachrichtenbeschreibung,X, + 7,Beginn der Nachricht,,BGM,,00002,,,,Muss, + 8,Beginn der Nachricht,,BGM,1001,00002,Z84,,Bestellung ÄnderungNetzentgelte aufgrundnetzorientierterSteuerungsmöglichkeit,X, + 9,Beginn der Nachricht,,BGM,1004,00002,,,Dokumentennummer,X, + 10,Nachrichtendatum,,DTM,,00003,,,,Muss, + 11,Nachrichtendatum,,DTM,2005,00003,137,,Dokumenten-/Nachrichtendatum/-zeit,X, + 12,Nachrichtendatum,,DTM,2380,00003,,,"Datum oder Uhrzeit oderZeitspanne, Wert",X [931] [494],"[494] Das hier genannte Datum muss der Zeitpunkt sein, zu dem das Dokument erstellt wurde, oder ein Zeitpunkt, der davor liegt. + [931] Format: ZZZ = +00" + 13,Nachrichtendatum,,DTM,2379,00003,303,,CCYYMMDDHHMMZZZ,X, + 14,Ausführungsdatum,,DTM,,00004,,,,Muss, + 15,Ausführungsdatum,,DTM,2005,00004,203,,Ausführungsdatum/-zeit,X, + 16,Ausführungsdatum,,DTM,2380,00004,,,"Datum oder Uhrzeit oderZeitspanne, Wert",X [UB1], + 17,Ausführungsdatum,,DTM,2379,00004,303,,CCYYMMDDHHMMZZZ,X, + 18,Prüfidentifikator,SG1,,,,,,,Muss, + 19,Prüfidentifikator,SG1,RFF,,00019,,,,Muss, + 20,Prüfidentifikator,SG1,RFF,1153,00019,Z13,,Prüfidentifikator,X, + 21,Prüfidentifikator,SG1,RFF,1154,00019,17010,,Bestellung ÄnderungNetzentgelte aufgrundnetzorientierterSteuerungsmöglichkeit,X, + 22,MP-ID Absender,SG2,,,,,,,Muss, + 23,MP-ID Absender,SG2,NAD,,00020,,,,Muss, + 24,MP-ID Absender,SG2,NAD,3035,00020,Nachrichtenaussteller bzw.-absender,,,MS, + 25,MP-ID Absender,SG2,NAD,3039,00020,,,MP-ID,X [61],[61] MP-ID nur aus Sparte Strom + 26,MP-ID Absender,SG2,NAD,3055,00020,9,,GS1,X, + 27,MP-ID Absender,SG2,NAD,3055,,293,,"DE, BDEW (Bundesverbandder Energie- undWasserwirtschaft e.V.)",X, + 28,Ansprechpartner,SG5,,,,,,,Kann, + 29,Ansprechpartner,SG5,CTA,,00021,,,,Muss, + 30,Ansprechpartner,SG5,CTA,3139,00021,,,,IC, + 31,Ansprechpartner,SG5,CTA,3412,00021,,,Kontakt,X, + 32,Kommunikationsverbindung,SG5,COM,,00022,,,,Muss, + 33,Kommunikationsverbindung,SG5,COM,3148,00022,,,"Kommunikationsadresse,Identifikation",X, + 34,Kommunikationsverbindung,SG5,COM,3155,00022,EM,,Elektronische Post,X [1P0..1], + 35,Kommunikationsverbindung,SG5,COM,3155,,FX,,Telefax,X [1P0..1], + 36,Kommunikationsverbindung,SG5,COM,3155,,TE,,Telefon,X [1P0..1], + 37,Kommunikationsverbindung,SG5,COM,3155,,AJ,,weiteres Telefon,X [1P0..1], + 38,Kommunikationsverbindung,SG5,COM,3155,,AL,,Handy,X [1P0..1], + 39,MP-ID Empfänger,SG2,,,,,,,Muss, + 40,MP-ID Empfänger,SG2,NAD,,00023,,,,Muss, + 41,MP-ID Empfänger,SG2,NAD,3035,00023,,,,MR, + 42,MP-ID Empfänger,SG2,NAD,3039,00023,,,MP-ID,X [61],[61] MP-ID nur aus Sparte Strom + 43,MP-ID Empfänger,SG2,NAD,3055,00023,9,,GS1,X, + 44,MP-ID Empfänger,SG2,NAD,3055,,293,,"DE, BDEW (Bundesverbandder Energie- undWasserwirtschaft e.V.)",X, + 45,Meldepunkt,SG2,,,,,,,Muss, + 46,Meldepunkt,SG2,NAD,,00025,,,,Muss, + 47,Meldepunkt,SG2,NAD,3035,00025,,,,DP, + 48,Meldepunkt,SG2,LOC,,00026,,,,Muss, + 49,Meldepunkt,SG2,LOC,3227,00026,,,,172, + 50,Meldepunkt,SG2,LOC,3225,00026,,,Identifikator,X [950] [521],"[521] Hinweis: Verwendung der ID der Marktlokation + [950] Format: Marktlokations-ID" + 51,Erforderliches Modul der Netzentgelte,SG29,,,,,,,Muss [2050],[2050] Pro Nachricht ist die SG29 genau einmal anzugeben + 52,Erforderliches Modul der Netzentgelte,SG29,LIN,,00121,,,,Muss, + 53,Erforderliches Modul der Netzentgelte,SG29,LIN,1082,00121,,,Positionsnummer,X [903],[903] Format: Möglicher Wert: 1 + 54,Erforderliches Modul der Netzentgelte,SG29,LIN,1229,00121,Netzentgelte,,,Z77, + 55,Erforderliches Modul der Netzentgelte,SG30,,,,,,,Muss [2093],[2093] Pro SG29 LIN (Erforderliches Modul der + 56,Erforderliches Modul der Netzentgelte,SG30,CCI,,00122,,,,Muss, + 57,Erforderliches Modul der Netzentgelte,SG30,CCI,7059,00122,,,,Z62, + 58,Erforderliches Modul der Netzentgelte,SG30,CCI,7037,00122,ZG3,,pauschaleNetzentgeltreduzierung(Modul 1),X [15P0..1] ⊻ [14P1..1], + 59,Erforderliches Modul der Netzentgelte,SG30,CCI,7037,,ZG4,,prozentuale ReduzierungArbeitspreis (Modul 2),X [15P0..1], + 60,Erforderliches Modul der Netzentgelte,SG30,CCI,7037,,ZG5,,Anreizmodul zeitvariablesNetzentgelt (Modul 3),X [13P0..1], + 61,Abschnitts-Kontrollsegment,,UNS,,00123,,,,Muss, + 62,Abschnitts-Kontrollsegment,,UNS,0081,00123,und Summenteil,,,S, + 63,Nachrichten-Endesegment,,UNT,,00125,,,,Muss, + 64,Nachrichten-Endesegment,,UNT,0074,00125,,,Anzahl der Segmente in einerNachricht,X, + 65,Nachrichten-Endesegment,,UNT,0062,00125,,,Nachrichten-Referenznummer,X, + + ''' +# --- +# name: TestCli.test_kohlrahbi_cli_with_valid_arguments[17114] + ''' + ,Segmentname,Segmentgruppe,Segment,Datenelement,Segment ID,Code,Qualifier,Beschreibung,Bedingungsausdruck,Bedingung + 0,Nachrichten-Kopfsegment,,UNH,,00001,,,,Muss, + 1,Nachrichten-Kopfsegment,,UNH,0062,00001,,,Nachrichten-Referenznummer,X, + 2,Nachrichten-Kopfsegment,,UNH,0065,00001,ORDERS,,Bestellung,X, + 3,Nachrichten-Kopfsegment,,UNH,0052,00001,D,,Entwurfs-Version,X, + 4,Nachrichten-Kopfsegment,,UNH,0054,00001,09B,,Ausgabe 2009 - B,X, + 5,Nachrichten-Kopfsegment,,UNH,0051,00001,UN,,UN/CEFACT,X, + 6,Nachrichten-Kopfsegment,,UNH,0057,00001,1.3,,Versionsnummer derzugrundeliegendenBDEW-Nachrichtenbeschreibung,X, + 7,Beginn der Nachricht,,BGM,,00002,,,,Muss, + 8,Beginn der Nachricht,,BGM,1001,00002,Z23,,Bilanzierte Menge(MMMA),X, + 9,Beginn der Nachricht,,BGM,1004,00002,,,Dokumentennummer,X, + 10,Nachrichtendatum,,DTM,,00003,,,,Muss, + 11,Nachrichtendatum,,DTM,2005,00003,137,,Dokumenten-/Nachrichtendatum/-zeit,X, + 12,Nachrichtendatum,,DTM,2380,00003,,,"Datum oder Uhrzeit oderZeitspanne, Wert",X [931] [494],"[494] Das hier genannte Datum muss der Zeitpunkt sein, zu dem das Dokument erstellt wurde, oder ein Zeitpunkt, der davor liegt. + [931] Format: ZZZ = +00" + 13,Nachrichtendatum,,DTM,2379,00003,303,,CCYYMMDDHHMMZZZ,X, + 14,Prüfidentifikator,SG1,,,,,,,Muss, + 15,Prüfidentifikator,SG1,RFF,,00019,,,,Muss, + 16,Prüfidentifikator,SG1,RFF,1153,00019,Z13,,Prüfidentifikator,X, + 17,Prüfidentifikator,SG1,RFF,1154,00019,17114,,Anforderung bilanzierteMenge,X, + 18,MP-ID Absender,SG2,,,,,,,Muss, + 19,MP-ID Absender,SG2,NAD,,00020,,,,Muss, + 20,MP-ID Absender,SG2,NAD,3035,00020,Nachrichtenaussteller bzw.-absender,,,MS, + 21,MP-ID Absender,SG2,NAD,3039,00020,,,MP-ID,X [61],[61] MP-ID nur aus Sparte Strom + 22,MP-ID Absender,SG2,NAD,3055,00020,9,,GS1,X, + 23,MP-ID Absender,SG2,NAD,3055,,293,,"DE, BDEW (Bundesverbandder Energie- undWasserwirtschaft e.V.)",X, + 24,Ansprechpartner,SG5,,,,,,,Kann, + 25,Ansprechpartner,SG5,CTA,,00021,,,,Muss, + 26,Ansprechpartner,SG5,CTA,3139,00021,,,,IC, + 27,Ansprechpartner,SG5,CTA,3412,00021,,,Kontakt,X, + 28,Kommunikationsverbindung,SG5,COM,,00022,,,,Muss, + 29,Kommunikationsverbindung,SG5,COM,3148,00022,,,"Kommunikationsadresse,Identifikation",X, + 30,Kommunikationsverbindung,SG5,COM,3155,00022,EM,,Elektronische Post,X [1P0..1], + 31,Kommunikationsverbindung,SG5,COM,3155,,FX,,Telefax,X [1P0..1], + 32,Kommunikationsverbindung,SG5,COM,3155,,TE,,Telefon,X [1P0..1], + 33,Kommunikationsverbindung,SG5,COM,3155,,AJ,,weiteres Telefon,X [1P0..1], + 34,Kommunikationsverbindung,SG5,COM,3155,,AL,,Handy,X [1P0..1], + 35,MP-ID Empfänger,SG2,,,,,,,Muss, + 36,MP-ID Empfänger,SG2,NAD,,00023,,,,Muss, + 37,MP-ID Empfänger,SG2,NAD,3035,00023,,,,MR, + 38,MP-ID Empfänger,SG2,NAD,3039,00023,,,MP-ID,X [61],[61] MP-ID nur aus Sparte Strom + 39,MP-ID Empfänger,SG2,NAD,3055,00023,9,,GS1,X, + 40,MP-ID Empfänger,SG2,NAD,3055,,293,,"DE, BDEW (Bundesverbandder Energie- undWasserwirtschaft e.V.)",X, + 41,Meldepunkt,SG2,,,,,,,Muss, + 42,Meldepunkt,SG2,NAD,,00025,,,,Muss, + 43,Meldepunkt,SG2,NAD,3035,00025,,,,DP, + 44,Meldepunkt,SG2,LOC,,00026,,,,Muss, + 45,Meldepunkt,SG2,LOC,3227,00026,,,,172, + 46,Meldepunkt,SG2,LOC,3225,00026,,,Identifikator,X [950] [521],"[521] Hinweis: Verwendung der ID der Marktlokation + [950] Format: Marktlokations-ID" + 47,Positionsdaten,SG29,,,,,,,Muss [2050],[2050] Pro Nachricht ist die SG29 genau einmal anzugeben + 48,Positionsdaten,SG29,LIN,,00040,,,,Muss, + 49,Positionsdaten,SG29,LIN,1082,00040,,,Positionsnummer,X [903],[903] Format: Möglicher Wert: 1 + 50,Beginn Zeitraum für Wertanfrage,SG29,DTM,,00045,,,,Muss, + 51,Beginn Zeitraum für Wertanfrage,SG29,DTM,2005,00045,163,,"Verarbeitung,Beginndatum/-zeit",X, + 52,Beginn Zeitraum für Wertanfrage,SG29,DTM,2380,00045,,,"Datum oder Uhrzeit oderZeitspanne, Wert",X [UB1], + 53,Beginn Zeitraum für Wertanfrage,SG29,DTM,2379,00045,303,,CCYYMMDDHHMMZZZ,X, + 54,Ende Zeitraum für Wertanfrage,SG29,DTM,,00046,,,,Muss, + 55,Ende Zeitraum für Wertanfrage,SG29,DTM,2005,00046,164,,"Verarbeitung,Endedatum/-zeit",X, + 56,Ende Zeitraum für Wertanfrage,SG29,DTM,2380,00046,,,"Datum oder Uhrzeit oderZeitspanne, Wert",X [UB1], + 57,Ende Zeitraum für Wertanfrage,SG29,DTM,2379,00046,303,,CCYYMMDDHHMMZZZ,X, + 58,Abschnitts-Kontrollsegment,,UNS,,00123,,,,Muss, + 59,Abschnitts-Kontrollsegment,,UNS,0081,00123,und Summenteil,,,S, + 60,Nachrichten-Endesegment,,UNT,,00125,,,,Muss, + 61,Nachrichten-Endesegment,,UNT,0074,00125,,,Anzahl der Segmente in einerNachricht,X, + 62,Nachrichten-Endesegment,,UNT,0062,00125,,,Nachrichten-Referenznummer,X, + + ''' +# --- +# name: TestCli.test_kohlrahbi_cli_with_valid_arguments[17129] + ''' + ,Segmentname,Segmentgruppe,Segment,Datenelement,Segment ID,Code,Qualifier,Beschreibung,Bedingungsausdruck,Bedingung + 0,Nachrichten-Kopfsegment,,UNH,,00001,,,,Muss, + 1,Nachrichten-Kopfsegment,,UNH,0062,00001,,,Nachrichten-Referenznummer,X, + 2,Nachrichten-Kopfsegment,,UNH,0065,00001,ORDERS,,Bestellung,X, + 3,Nachrichten-Kopfsegment,,UNH,0052,00001,D,,Entwurfs-Version,X, + 4,Nachrichten-Kopfsegment,,UNH,0054,00001,09B,,Ausgabe 2009 - B,X, + 5,Nachrichten-Kopfsegment,,UNH,0051,00001,UN,,UN/CEFACT,X, + 6,Nachrichten-Kopfsegment,,UNH,0057,00001,1.3,,Versionsnummer derzugrundeliegendenBDEW-Nachrichtenbeschreibung,X, + 7,Beginn der Nachricht,,BGM,,00002,,,,Muss, + 8,Beginn der Nachricht,,BGM,1001,00002,Z72,,Beendigung einerKonfiguration,X, + 9,Beginn der Nachricht,,BGM,1004,00002,,,Dokumentennummer,X, + 10,Nachrichtendatum,,DTM,,00003,,,,Muss, + 11,Nachrichtendatum,,DTM,2005,00003,137,,Dokumenten-/Nachrichtendatum/-zeit,X, + 12,Nachrichtendatum,,DTM,2380,00003,,,"Datum oder Uhrzeit oderZeitspanne, Wert",X [931] [494],"[494] Das hier genannte Datum muss der Zeitpunkt sein, zu dem das Dokument erstellt wurde, oder ein Zeitpunkt, der davor liegt. + [931] Format: ZZZ = +00" + 13,Nachrichtendatum,,DTM,2379,00003,303,,CCYYMMDDHHMMZZZ,X, + 14,Ausführungsdatum,,DTM,,00004,,,,Muss, + 15,Ausführungsdatum,,DTM,2005,00004,203,,Ausführungsdatum/-zeit,X, + 16,Ausführungsdatum,,DTM,2380,00004,,,"Datum oder Uhrzeit oderZeitspanne, Wert",X [UB1], + 17,Ausführungsdatum,,DTM,2379,00004,303,,CCYYMMDDHHMMZZZ,X, + 18,Referenznummer der Nachricht der betroffenen Antwort auf Bestellung ,SG1,,,,,,,Muss, + 19,Referenznummer der Nachricht der betroffenen Antwort auf Bestellung ,SG1,RFF,,00017,,,,Muss, + 20,Referenznummer der Nachricht der betroffenen Antwort auf Bestellung ,SG1,RFF,1153,00017,Z42,,Referenznummer derNachricht der betroffenenAntwort auf Bestellung(Bestellbestätigung),X, + 21,Referenznummer der Nachricht der betroffenen Antwort auf Bestellung ,SG1,RFF,1154,00017,,,"Referenz, Identifikation",X [562],[562] Hinweis: Wert aus BGM+Z73 DE1004 der IFTSTA mit der die Antwort auf die Bestellung der Konfiguration übermittelt wurde + 22,Referenznummer des Vorgangs der betroffenen Antwort auf Bestellung,SG1,,,,,,,Muss, + 23,Referenznummer des Vorgangs der betroffenen Antwort auf Bestellung,SG1,RFF,,00018,,,,Muss, + 24,Referenznummer des Vorgangs der betroffenen Antwort auf Bestellung,SG1,RFF,1153,00018,Z43,,Referenznummer desVorgangs der betroffenenAntwort auf Bestellung(Bestellbestätigung),X, + 25,Referenznummer des Vorgangs der betroffenen Antwort auf Bestellung,SG1,RFF,1154,00018,,,"Referenz, Identifikation",X [563],[563] Hinweis: Vorgangsnummer aus CNI DE1490 der IFTSTA mit BGM+Z73 mit der die Antwort auf die Bestellung der Konfiguration übermittelt wurde + 26,Prüfidentifikator,SG1,,,,,,,Muss, + 27,Prüfidentifikator,SG1,RFF,,00019,,,,Muss, + 28,Prüfidentifikator,SG1,RFF,1153,00019,Z13,,Prüfidentifikator,X, + 29,Prüfidentifikator,SG1,RFF,1154,00019,17129,,Bestellung Beendigungeiner Konfiguration,X, + 30,MP-ID Absender,SG2,,,,,,,Muss, + 31,MP-ID Absender,SG2,NAD,,00020,,,,Muss, + 32,MP-ID Absender,SG2,NAD,3035,00020,Nachrichtenaussteller bzw.-absender,,,MS, + 33,MP-ID Absender,SG2,NAD,3039,00020,,,MP-ID,X [61],[61] MP-ID nur aus Sparte Strom + 34,MP-ID Absender,SG2,NAD,3055,00020,9,,GS1,X, + 35,MP-ID Absender,SG2,NAD,3055,,293,,"DE, BDEW (Bundesverbandder Energie- undWasserwirtschaft e.V.)",X, + 36,Ansprechpartner,SG5,,,,,,,Kann, + 37,Ansprechpartner,SG5,CTA,,00021,,,,Muss, + 38,Ansprechpartner,SG5,CTA,3139,00021,,,,IC, + 39,Ansprechpartner,SG5,CTA,3412,00021,,,Kontakt,X, + 40,Kommunikationsverbindung,SG5,COM,,00022,,,,Muss, + 41,Kommunikationsverbindung,SG5,COM,3148,00022,,,"Kommunikationsadresse,Identifikation",X, + 42,Kommunikationsverbindung,SG5,COM,3155,00022,EM,,Elektronische Post,X [1P0..1], + 43,Kommunikationsverbindung,SG5,COM,3155,,FX,,Telefax,X [1P0..1], + 44,Kommunikationsverbindung,SG5,COM,3155,,TE,,Telefon,X [1P0..1], + 45,Kommunikationsverbindung,SG5,COM,3155,,AJ,,weiteres Telefon,X [1P0..1], + 46,Kommunikationsverbindung,SG5,COM,3155,,AL,,Handy,X [1P0..1], + 47,MP-ID Empfänger,SG2,,,,,,,Muss, + 48,MP-ID Empfänger,SG2,NAD,,00023,,,,Muss, + 49,MP-ID Empfänger,SG2,NAD,3035,00023,,,,MR, + 50,MP-ID Empfänger,SG2,NAD,3039,00023,,,MP-ID,X [61],[61] MP-ID nur aus Sparte Strom + 51,MP-ID Empfänger,SG2,NAD,3055,00023,9,,GS1,X, + 52,MP-ID Empfänger,SG2,NAD,3055,,293,,"DE, BDEW (Bundesverbandder Energie- undWasserwirtschaft e.V.)",X, + 53,Abschnitts-Kontrollsegment,,UNS,,00123,,,,Muss, + 54,Abschnitts-Kontrollsegment,,UNS,0081,00123,und Summenteil,,,S, + 55,Nachrichten-Endesegment,,UNT,,00125,,,,Muss, + 56,Nachrichten-Endesegment,,UNT,0074,00125,,,Anzahl der Segmente in einerNachricht,X, + 57,Nachrichten-Endesegment,,UNT,0062,00125,,,Nachrichten-Referenznummer,X, + + ''' +# --- +# name: TestCli.test_kohlrahbi_cli_with_valid_arguments[17201] + ''' + ,Segmentname,Segmentgruppe,Segment,Datenelement,Segment ID,Code,Qualifier,Beschreibung,Bedingungsausdruck,Bedingung + 0,Nachrichten-Kopfsegment,,UNH,,00001,,,,Muss, + 1,Nachrichten-Kopfsegment,,UNH,0062,00001,,,Nachrichten-Referenznummer,X, + 2,Nachrichten-Kopfsegment,,UNH,0065,00001,ORDERS,,Bestellung,X, + 3,Nachrichten-Kopfsegment,,UNH,0052,00001,D,,Entwurfs-Version,X, + 4,Nachrichten-Kopfsegment,,UNH,0054,00001,09B,,Ausgabe 2009 - B,X, + 5,Nachrichten-Kopfsegment,,UNH,0051,00001,UN,,UN/CEFACT,X, + 6,Nachrichten-Kopfsegment,,UNH,0057,00001,1.3,,VersionsnummerderzugrundeliegendenBDEW-Nachrichtenbeschreibung,X, + 7,Beginn der Nachricht,,BGM,,00002,,,,Muss, + 8,Beginn der Nachricht,,BGM,1001,00002,E40,,Bilanzkreiszuordnungsliste,, + 9,Beginn der Nachricht,,BGM,1001,,Z05,,Clearingliste,, + 10,Beginn der Nachricht,,BGM,1001,,Z19,,normiertes Profil/Profilschar,X, + 11,Beginn der Nachricht,,BGM,1004,00002,,,Dokumentennummer,X, + 12,Nachrichtendatum,,DTM,,00003,,,,Muss, + 13,Nachrichtendatum,,DTM,2005,00003,137,,Dokumenten-/Nachrichtendatum/-zeit,X, + 14,Nachrichtendatum,,DTM,2380,00003,,,"Datum oder Uhrzeit oderZeitspanne, Wert",X [931][494],"[494] Das hier genannte Datum muss der Zeitpunkt sein, zu dem das Dokument erstellt wurde, oder ein Zeitpunkt, der davor liegt. + [931] Format: ZZZ = +00" + 15,Nachrichtendatum,,DTM,2379,00003,303,,CCYYMMDDHHMMZZZ,X, + 16,Ausführungsdatum,,DTM,,00004,,,,,"[33] Wenn IMD+Z01 vorhanden + [34] Wenn IMD+Z02 vorhanden" + 17,Ausführungsdatum,,DTM,2005,00004,203,,Ausführungsdatum/-zeit,, + 18,Ausführungsdatum,,DTM,2380,00004,,,Datum oder Uhrzeit oder,, + 19,Ausführungsdatum,,DTM,2379,00004,303,,CCYYMMDDHHMMZZZ,, + 20,Betrachtungszeitintervall,,DTM,,00006,,,,,[1] Wenn IMD+Z03 vorhanden + 21,Betrachtungszeitintervall,,DTM,2005,00006,273,,Gültigkeitszeitspanne,, + 22,Betrachtungszeitintervall,,DTM,2380,00006,,,"Datum oder Uhrzeit oderZeitspanne, Wert",, + 23,Betrachtungszeitintervall,,DTM,2379,00006,610,,CCYYMM,, + 24,Abonnement,,IMD,,00008,,,,Muss, + 25,Abonnement,,IMD,7081,00008,Z01,,Start Abo,X, + 26,Abonnement,,IMD,7081,,Z02,,Ende Abo,X, + 27,Abonnement,,IMD,7081,,Z03,,ohne Abo,, + 28,Prüfidentifikator,SG1,,,,,,,Muss, + 29,Prüfidentifikator,SG1,RFF,,00019,,,,Muss, + 30,Prüfidentifikator,SG1,RFF,1153,00019,Z13,,Prüfidentifikator,X, + 31,Prüfidentifikator,SG1,RFF,1154,00019,17201,,AnforderungnormierterProfile/Profilscharen,X, + 32,Prüfidentifikator,SG1,RFF,1154,,17202,,AnforderungLieferantenclearingliste,, + 33,Prüfidentifikator,SG1,RFF,1154,,17203,,AnforderungBilanzkreiszuordnungsliste,, + 34,Prüfidentifikator,SG1,RFF,1154,,17204,,AnforderungClearingliste BAS,, + 35,Prüfidentifikator,SG1,RFF,1154,,17205,,AnforderungClearingliste DZR,, + 36,MP-ID Absender,SG2,,,,,,,Muss, + 37,MP-ID Absender,SG2,NAD,,00020,,,,Muss, + 38,MP-ID Absender,SG2,NAD,3035,00020,MS,,Dokumenten-/Nachrichtenaussteller bzw. -absender,X, + 39,MP-ID Absender,SG2,NAD,3039,00020,,,MP-ID,X [61],[61] MP-ID nur aus Sparte Strom + 40,MP-ID Absender,SG2,NAD,3055,00020,9,,GS1,X, + 41,MP-ID Absender,SG2,NAD,3055,,293,,"DE, BDEW(Bundesverbandder Energie- undWasserwirtschafte.V.)",X, + 42,Ansprechpartner,SG5,,,,,,,Kann, + 43,Ansprechpartner,SG5,CTA,,00021,,,,Muss, + 44,Ansprechpartner,SG5,CTA,3139,00021,IC,,Informationskontakt,X, + 45,Ansprechpartner,SG5,CTA,3412,00021,,,Kontakt,X, + 46,Kommunikationsverbindu ng,SG5,COM,,00022,,,,Muss, + 47,Kommunikationsverbindu ng,SG5,COM,3148,00022,,,"Kommunikationsadresse,Identifikation",X, + 48,Kommunikationsverbindu ng,SG5,COM,3155,00022,EM,,Elektronische Post,X [1P0..1], + 49,Kommunikationsverbindu ng,SG5,COM,3155,,FX,,Telefax,X [1P0..1], + 50,Kommunikationsverbindu ng,SG5,COM,3155,,TE,,Telefon,X [1P0..1], + 51,Kommunikationsverbindu ng,SG5,COM,3155,,AJ,,weiteres Telefon,X [1P0..1], + 52,Kommunikationsverbindu ng,SG5,COM,3155,,AL,,Handy,X [1P0..1], + 53,MP-ID Empfänger,SG2,,,,,,,Muss, + 54,MP-ID Empfänger,SG2,NAD,,00023,,,,Muss, + 55,MP-ID Empfänger,SG2,NAD,3035,00023,MR,,Nachrichtenempfänger,X, + 56,MP-ID Empfänger,SG2,NAD,3039,00023,,,MP-ID,X [61],[61] MP-ID nur aus Sparte Strom + 57,MP-ID Empfänger,SG2,NAD,3055,00023,9,,GS1,X, + 58,MP-ID Empfänger,SG2,NAD,3055,,293,,"DE, BDEW(Bundesverbandder Energie- undWasserwirtschafte.V.)",X, + 59,Bilanzierungsgebiet/ Regelzone,SG2,LOC,,00024,,,,,[1] Wenn IMD+Z03 vorhanden + 60,Bilanzierungsgebiet/ Regelzone,SG2,LOC,3227,00024,107,,Bilanzierungsgebiet,, + 61,Bilanzierungsgebiet/ Regelzone,SG2,LOC,3227,,231,,Regelzone,,[36] Wenn MP-ID in SG2 NAD+MR mit Rolle NB nicht vorhanden + 62,Bilanzierungsgebiet/ Regelzone,SG2,LOC,3225,00024,,,Bilanzierungsgebiet/Regelzone,, + 63,Positionsdaten,SG29,,,,,,,Muss[2050],[2050] Pro Nachricht ist die SG29 genau einmal anzugeben + 64,Positionsdaten,SG29,LIN,,00040,,,,Muss, + 65,Positionsdaten,SG29,LIN,1082,00040,,,Positionsnummer,X [903],[903] Format: Möglicher Wert: 1 + 66,Profilgruppe,SG30,,,,,,,Muss, + 67,Profilgruppe,SG30,CCI,,00050,,,,Muss, + 68,Profilgruppe,SG30,CCI,7059,00050,Z02,,Standardlastprofil,X, + 69,Profilgruppe,SG30,CCI,7059,,Z03,,tagesparameterabhängiges Lastprofil,X, + 70,Profilgruppe,SG30,CCI,7059,,Z04,,Standardeinspeiseprofil,X, + 71,Profilgruppe,SG30,CCI,7059,,Z05,,tagesparameterabhängigesEinspeiseprofil,X, + 72,Versionsangabe der Summenzeitreihe,SG34,,,,,,,,[1] Wenn IMD+Z03 vorhanden + 73,Versionsangabe der Summenzeitreihe,SG34,RFF,,00060,,,,, + 74,Versionsangabe der Summenzeitreihe,SG34,RFF,1153,00060,AUU,,Referenz auf eineZeitreihe,, + 75,Versionsangabe der Summenzeitreihe,SG34,RFF,1154,00060,,,Version,, + 76,Meldepunkt,SG38,,,,,,,, + 77,Meldepunkt,SG38,LOC,,00063,,,,, + 78,Meldepunkt,SG38,LOC,3227,00063,172,,Meldepunkt,, + 79,Meldepunkt,SG38,LOC,3225,00063,,,Meldepunkt,,"[500] Hinweis: Zählpunkt der BAS + [501] Hinweis: Zählpunkt der DZR + [951] Format: Zählpunktbezeichnu ng" + 80,Bilanzkreis für Strom,SG38,,,,,,,, + 81,Bilanzkreis für Strom,SG38,LOC,,00064,,,,, + 82,Bilanzkreis für Strom,SG38,LOC,3227,00064,237,,Bilanzkreis,, + 83,Bilanzkreis für Strom,SG38,LOC,3225,00064,,,Bilanzkreis,, + 84,Abschnitts- Kontrollsegment,,UNS,,00123,,,,Muss, + 85,Abschnitts- Kontrollsegment,,UNS,0081,00123,S,,Trennung vonPositions- undSummenteil,X, + 86,Nachrichten- Endesegment,,UNT,,00125,,,,Muss, + 87,Nachrichten- Endesegment,,UNT,0074,00125,,,Anzahl der Segmente ineiner Nachricht,X, + 88,Nachrichten- Endesegment,,UNT,0062,00125,,,Nachrichten-Referenznummer,X, + + ''' +# --- +# name: TestCli.test_kohlrahbi_cli_with_valid_arguments[17208] + ''' + ,Segmentname,Segmentgruppe,Segment,Datenelement,Segment ID,Code,Qualifier,Beschreibung,Bedingungsausdruck,Bedingung + 0,Nachrichten-Kopfsegment,,UNH,,00001,,,,Muss, + 1,Nachrichten-Kopfsegment,,UNH,0062,00001,,,Nachrichten-Referenznummer,X, + 2,Nachrichten-Kopfsegment,,UNH,0065,00001,ORDERS,,Bestellung,X, + 3,Nachrichten-Kopfsegment,,UNH,0052,00001,D,,Entwurfs-Version,X, + 4,Nachrichten-Kopfsegment,,UNH,0054,00001,09B,,Ausgabe 2009 - B,X, + 5,Nachrichten-Kopfsegment,,UNH,0051,00001,UN,,UN/CEFACT,X, + 6,Nachrichten-Kopfsegment,,UNH,0057,00001,1.3,,Versionsnummer derzugrundeliegendenBDEW-Nachrichtenbeschreibung,X, + 7,Beginn der Nachricht,,BGM,,00002,,,,Muss, + 8,Beginn der Nachricht,,BGM,1001,00002,Z05,,Clearingliste,X, + 9,Beginn der Nachricht,,BGM,1001,,BK,,Zeitreihen im RahmenderBilanzkreisabrechnung,, + 10,Beginn der Nachricht,,BGM,1004,00002,,,Dokumentennummer,X, + 11,Nachrichtendatum,,DTM,,00003,,,,Muss, + 12,Nachrichtendatum,,DTM,2005,00003,137,,Dokumenten-/Nachrichtendatum/-zeit,X, + 13,Nachrichtendatum,,DTM,2380,00003,,,"Datum oder Uhrzeit oderZeitspanne, Wert",X [931][494],"[494] Das hier genannte Datum muss der Zeitpunkt sein, zu dem das Dokument erstellt wurde, oder ein Zeitpunkt, der davor liegt. + [931] Format: ZZZ = +00" + 14,Nachrichtendatum,,DTM,2379,00003,303,,CCYYMMDDHHMMZZZ,X, + 15,Ausführungsdatum,,DTM,,00004,,,,,"[33] Wenn IMD+Z01 vorhanden + [34] Wenn IMD+Z02 vorhanden" + 16,Ausführungsdatum,,DTM,2005,00004,203,,Ausführungsdatum/-zeit,, + 17,Ausführungsdatum,,DTM,2380,00004,,,"Datum oder Uhrzeit oderZeitspanne, Wert",, + 18,Ausführungsdatum,,DTM,2379,00004,303,,CCYYMMDDHHMMZZZ,, + 19,Betrachtungszeitintervall,,DTM,,00006,,,,Muss,[1] Wenn IMD+Z03 vorhanden + 20,Betrachtungszeitintervall,,DTM,2005,00006,273,,Gültigkeitszeitspanne,X, + 21,Betrachtungszeitintervall,,DTM,2380,00006,,,"Datum oder Uhrzeit oderZeitspanne, Wert",X, + 22,Betrachtungszeitintervall,,DTM,2379,00006,610,,CCYYMM,X, + 23,Abonnement,,IMD,,00008,,,,Muss, + 24,Abonnement,,IMD,7081,00008,Z01,,Start Abo,, + 25,Abonnement,,IMD,7081,,Z02,,Ende Abo,, + 26,Abonnement,,IMD,7081,,Z03,,ohne Abo,X, + 27,Prüfidentifikator,SG1,,,,,,,Muss, + 28,Prüfidentifikator,SG1,RFF,,00019,,,,Muss, + 29,Prüfidentifikator,SG1,RFF,1153,00019,Z13,,Prüfidentifikator,X, + 30,Prüfidentifikator,SG1,RFF,1154,00019,17206,,AnforderungBilanzierungsgebietsclearingliste,, + 31,Prüfidentifikator,SG1,RFF,1154,,17207,,Ab-/Bestellung BK-SZRauf AggregationsebeneRZ,, + 32,Prüfidentifikator,SG1,RFF,1154,,17208,,AnforderungClearingliste ÜNB-DZR,X, + 33,MP-ID Absender,SG2,,,,,,,Muss, + 34,MP-ID Absender,SG2,NAD,,00020,,,,Muss, + 35,MP-ID Absender,SG2,NAD,3035,00020,MS,,Dokumenten-/Nachrichtenausstellerbzw. -absender,X, + 36,MP-ID Absender,SG2,NAD,3039,00020,,,MP-ID,X [61],[61] MP-ID nur aus Sparte Strom + 37,MP-ID Absender,SG2,NAD,3055,00020,9,,GS1,X, + 38,MP-ID Absender,SG2,NAD,3055,,293,,"DE, BDEW(Bundesverband derEnergie- undWasserwirtschaft e.V.)",X, + 39,Ansprechpartner,SG5,,,,,,,Kann, + 40,Ansprechpartner,SG5,CTA,,00021,,,,Muss, + 41,Ansprechpartner,SG5,CTA,3139,00021,IC,,Informationskontakt,X, + 42,Ansprechpartner,SG5,CTA,3412,00021,,,Kontakt,X, + 43,Kommunikationsverbindung,SG5,COM,,00022,,,,Muss, + 44,Kommunikationsverbindung,SG5,COM,3148,00022,,,"Kommunikationsadresse,Identifikation",X, + 45,Kommunikationsverbindung,SG5,COM,3155,00022,EM,,Elektronische Post,X [1P0..1], + 46,Kommunikationsverbindung,SG5,COM,3155,,FX,,Telefax,X [1P0..1], + 47,Kommunikationsverbindung,SG5,COM,3155,,TE,,Telefon,X [1P0..1], + 48,Kommunikationsverbindung,SG5,COM,3155,,AJ,,weiteres Telefon,X [1P0..1], + 49,Kommunikationsverbindung,SG5,COM,3155,,AL,,Handy,X [1P0..1], + 50,MP-ID Empfänger,SG2,,,,,,,Muss, + 51,MP-ID Empfänger,SG2,NAD,,00023,,,,Muss, + 52,MP-ID Empfänger,SG2,NAD,3035,00023,MR,,Nachrichtenempfänger,X, + 53,MP-ID Empfänger,SG2,NAD,3039,00023,,,MP-ID,X [61],[61] MP-ID nur aus Sparte Strom + 54,MP-ID Empfänger,SG2,NAD,3055,00023,9,,GS1,X, + 55,MP-ID Empfänger,SG2,NAD,3055,,293,,"DE, BDEW(Bundesverband derEnergie- undWasserwirtschaft e.V.)",X, + 56,Positionsdaten,SG29,,,,,,,Muss [2050],[2050] Pro Nachricht ist die SG29 genau einmal anzugeben + 57,Positionsdaten,SG29,LIN,,00040,,,,Muss, + 58,Positionsdaten,SG29,LIN,1082,00040,,,Positionsnummer,X [903],[903] Format: Möglicher Wert: 1 + 59,Versionsangabe der Summenzeitreihe,SG34,,,,,,,Muss,[1] Wenn IMD+Z03 vorhanden + 60,Versionsangabe der Summenzeitreihe,SG34,RFF,,00060,,,,Muss, + 61,Versionsangabe der Summenzeitreihe,SG34,RFF,1153,00060,AUU,,Referenz auf eineZeitreihe,X, + 62,Versionsangabe der Summenzeitreihe,SG34,RFF,1154,00060,,,Version,X, + 63,Meldepunkt,SG38,,,,,,,Muss, + 64,Meldepunkt,SG38,LOC,,00063,,,,Muss, + 65,Meldepunkt,SG38,LOC,3227,00063,172,,Meldepunkt,X, + 66,Meldepunkt,SG38,LOC,3225,00063,,,Meldepunkt,X [951][501],"[501] Hinweis: Zählpunkt der DZR + [527] Hinweis: Zählpunkt der BG-SZR (Kategorie B) + [951] Format: Zählpunktbezeichnung" + 67,Bilanzkreis für Strom,SG38,,,,,,,, + 68,Bilanzkreis für Strom,SG38,LOC,,00064,,,,, + 69,Bilanzkreis für Strom,SG38,LOC,3227,00064,237,,Bilanzkreis,, + 70,Bilanzkreis für Strom,SG38,LOC,3225,00064,,,Bilanzkreis,, + 71,Abschnitts-Kontrollsegment,,UNS,,00123,,,,Muss, + 72,Abschnitts-Kontrollsegment,,UNS,0081,00123,S,,Trennung von Positions-und Summenteil,X, + 73,Nachrichten-Endesegment,,UNT,,00125,,,,Muss, + 74,Nachrichten-Endesegment,,UNT,0074,00125,,,Anzahl der Segmente in einerNachricht,X, + 75,Nachrichten-Endesegment,,UNT,0062,00125,,,Nachrichten-Referenznummer,X, + + ''' +# --- +# name: TestCli.test_kohlrahbi_cli_with_valid_arguments[17301] + ''' + ,Segmentname,Segmentgruppe,Segment,Datenelement,Segment ID,Code,Qualifier,Beschreibung,Bedingungsausdruck,Bedingung + 0,Nachrichten-Kopfsegment,,UNH,,00001,,,,Muss, + 1,Nachrichten-Kopfsegment,,UNH,0062,00001,,,Nachrichten-Referenznummer,X, + 2,Nachrichten-Kopfsegment,,UNH,0065,00001,ORDERS,,Bestellung,X, + 3,Nachrichten-Kopfsegment,,UNH,0052,00001,D,,Entwurfs-Version,X, + 4,Nachrichten-Kopfsegment,,UNH,0054,00001,09B,,Ausgabe 2009 - B,X, + 5,Nachrichten-Kopfsegment,,UNH,0051,00001,UN,,UN/CEFACT,X, + 6,Nachrichten-Kopfsegment,,UNH,0057,00001,1.3,,Versionsnummer derzugrundeliegendenBDEW-Nachrichtenbeschreibung,X, + 7,Beginn der Nachricht,,BGM,,00002,,,,Muss, + 8,Beginn der Nachricht,,BGM,1001,00002,7,,Prozessdatenbericht,X, + 9,Beginn der Nachricht,,BGM,1001,,Z14,,Stammdaten der Markt-oder Messlokation,X, + 10,Beginn der Nachricht,,BGM,1004,00002,,,Dokumentennummer,X, + 11,Nachrichtendatum,,DTM,,00003,,,,Muss, + 12,Nachrichtendatum,,DTM,2005,00003,137,,Dokumenten-/Nachrichtendatum/-zeit,X, + 13,Nachrichtendatum,,DTM,2380,00003,,,"Datum oder Uhrzeit oderZeitspanne, Wert",X [931] [494],"[494] Das hier genannte Datum muss der Zeitpunkt sein, zu dem das Dokument erstellt wurde, oder ein Zeitpunkt, der davor liegt. + [931] Format: ZZZ = +00" + 14,Nachrichtendatum,,DTM,2379,00003,303,,CCYYMMDDHHMMZZZ,X, + 15,Ausführungsdatum,,DTM,,00004,,,,Muss, + 16,Ausführungsdatum,,DTM,2005,00004,203,,Ausführungsdatum/-zeit,X, + 17,Ausführungsdatum,,DTM,2380,00004,,,"Datum oder Uhrzeit oderZeitspanne, Wert",X [UB1], + 18,Ausführungsdatum,,DTM,2379,00004,303,,CCYYMMDDHHMMZZZ,X, + 19,Abonnement,,IMD,,00008,,,,Muss, + 20,Abonnement,,IMD,7081,00008,Z01,,Start Abo,X, + 21,Abonnement,,IMD,7081,,Z02,,Ende Abo,X, + 22,Produkt-/ Leistungsbeschreibung,,IMD,,00009,,,,Muss [2],[2] Wenn BGM+7 vorhanden + 23,Produkt-/ Leistungsbeschreibung,,IMD,7081,00009,Z11,,Lastgangdaten,X, + 24,Produkt-/ Leistungsbeschreibung,,IMD,7081,,Z12,,Zählerstände,X, + 25,Prüfidentifikator,SG1,,,,,,,Muss, + 26,Prüfidentifikator,SG1,RFF,,00019,,,,Muss, + 27,Prüfidentifikator,SG1,RFF,1153,00019,Z13,,Prüfidentifikator,X, + 28,Prüfidentifikator,SG1,RFF,1154,00019,17301,,Anforderung Abo,X, + 29,MP-ID Absender,SG2,,,,,,,Muss, + 30,MP-ID Absender,SG2,NAD,,00020,,,,Muss, + 31,MP-ID Absender,SG2,NAD,3035,00020,Nachrichtenaussteller bzw.-absender,,,MS, + 32,MP-ID Absender,SG2,NAD,3039,00020,,,MP-ID,X [61],[61] MP-ID nur aus Sparte Strom + 33,MP-ID Absender,SG2,NAD,3055,00020,9,,GS1,X, + 34,Ansprechpartner,SG5,,,,,,,Kann, + 35,Ansprechpartner,SG5,CTA,,00021,,,,Muss, + 36,Ansprechpartner,SG5,CTA,3139,00021,,,,IC, + 37,Ansprechpartner,SG5,CTA,3412,00021,,,Kontakt,X, + 38,Kommunikationsverbindung,SG5,COM,,00022,,,,Muss, + 39,Kommunikationsverbindung,SG5,COM,3148,00022,,,"Kommunikationsadresse,Identifikation",X, + 40,Kommunikationsverbindung,SG5,COM,3155,00022,EM,,Elektronische Post,X [1P0..1], + 41,Kommunikationsverbindung,SG5,COM,3155,,FX,,Telefax,X [1P0..1], + 42,Kommunikationsverbindung,SG5,COM,3155,,TE,,Telefon,X [1P0..1], + 43,Kommunikationsverbindung,SG5,COM,3155,,AJ,,weiteres Telefon,X [1P0..1], + 44,Kommunikationsverbindung,SG5,COM,3155,,AL,,Handy,X [1P0..1], + 45,MP-ID Empfänger,SG2,,,,,,,Muss, + 46,MP-ID Empfänger,SG2,NAD,,00023,,,,Muss, + 47,MP-ID Empfänger,SG2,NAD,3035,00023,,,,MR, + 48,MP-ID Empfänger,SG2,NAD,3039,00023,,,MP-ID,X [61],[61] MP-ID nur aus Sparte Strom + 49,MP-ID Empfänger,SG2,NAD,3055,00023,9,,GS1,X, + 50,MP-ID Empfänger,SG2,NAD,3055,,293,,"DE, BDEW (Bundesverbandder Energie- undWasserwirtschaft e.V.)",X, + 51,Meldepunkt,SG2,,,,,,,Muss, + 52,Meldepunkt,SG2,NAD,,00025,,,,Muss, + 53,Meldepunkt,SG2,NAD,3035,00025,,,,DP, + 54,Meldepunkt,SG2,LOC,,00026,,,,Muss, + 55,Meldepunkt,SG2,LOC,3227,00026,,,,172, + 56,Meldepunkt,SG2,LOC,3225,00026,,,Identifikator,X (([950] [521]) ⊻ ([951][522]) ⊻ ([950] [523])),"[521] Hinweis: Verwendung der ID der Marktlokation + [522] Hinweis: Verwendung der ID der Messlokation + [523] Hinweis: Verwendung der ID der Tranche + [950] Format: Marktlokations-ID + [951] Format: Zählpunktbezeichnung" + 57,Abschnitts-Kontrollsegment,,UNS,,00123,,,,Muss, + 58,Abschnitts-Kontrollsegment,,UNS,0081,00123,,,,S, + 59,Nachrichten-Endesegment,,UNT,,00125,,,,Muss, + 60,Nachrichten-Endesegment,,UNT,0074,00125,,,Anzahl der Segmente in einerNachricht,X, + 61,Nachrichten-Endesegment,,UNT,0062,00125,,,Nachrichten-Referenznummer,X, + + ''' +# --- +# name: TestCli.test_kohlrahbi_cli_with_valid_arguments[19002] + ''' + ,Segmentname,Segmentgruppe,Segment,Datenelement,Segment ID,Code,Qualifier,Beschreibung,Bedingungsausdruck,Bedingung + 0,Nachrichten-Kopfsegment,,UNH,,00001,,,,Muss, + 1,Nachrichten-Kopfsegment,,UNH,0062,00001,,,Nachrichten-Referenznummer,X, + 2,Nachrichten-Kopfsegment,,UNH,0065,00001,ORDRSP,,Bestellantwort,X, + 3,Nachrichten-Kopfsegment,,UNH,0052,00001,D,,Entwurfs-Version,X, + 4,Nachrichten-Kopfsegment,,UNH,0054,00001,10A,,Ausgabe 2010 - A,X, + 5,Nachrichten-Kopfsegment,,UNH,0051,00001,UN,,UN/CEFACT,X, + 6,Nachrichten-Kopfsegment,,UNH,0057,00001,1.3,,Versionsnummer derzugrundeliegendenBDEW-Nachrichtenbeschreibung,X, + 7,Beginn der Nachricht,,BGM,,00002,,,,Muss, + 8,Beginn der Nachricht,,BGM,1001,00002,Z10,,Geräteübernahme,X, + 9,Beginn der Nachricht,,BGM,1004,00002,,,Dokumentennummer,X, + 10,Nachrichtendatum,,DTM,,00003,,,,Muss, + 11,Nachrichtendatum,,DTM,2005,00003,137,,Dokumenten-/Nachrichtendatum/-zeit,X, + 12,Nachrichtendatum,,DTM,2380,00003,,,"Datum oder Uhrzeit oderZeitspanne, Wert",X [931] [494],"[494] Das hier genannte Datum muss der Zeitpunkt sein, zu dem das Dokument erstellt wurde, oder ein Zeitpunkt, der davor liegt. + [931] Format: ZZZ = +00" + 13,Nachrichtendatum,,DTM,2379,00003,303,,CCYYMMDDHHMMZZZ,X, + 14,Ausführungsdatum,,DTM,,00004,,,,Muss, + 15,Ausführungsdatum,,DTM,2005,00004,203,,Ausführungsdatum/-zeit,X, + 16,Ausführungsdatum,,DTM,2380,00004,,,"Datum oder Uhrzeit oderZeitspanne, Wert",X [UB3], + 17,Ausführungsdatum,,DTM,2379,00004,303,,CCYYMMDDHHMMZZZ,X, + 18,Produkt-/ Leistungsbeschreibung,,IMD,,00008,,,,Muss, + 19,Produkt-/ Leistungsbeschreibung,,IMD,7081,00008,Z07,,Kauf,X, + 20,Produkt-/ Leistungsbeschreibung,,IMD,7081,,Z08,,Nutzungsüberlassung,X, + 21,Referenz Nachrichtennummer,SG1,,,,,,,Muss, + 22,Referenz Nachrichtennummer,SG1,RFF,,00009,,,,Muss, + 23,Referenz Nachrichtennummer,SG1,RFF,1153,00009,ON,,Auftragsnummer(Einkauf),X, + 24,Referenz Nachrichtennummer,SG1,RFF,1154,00009,,,Referenz Nachrichtennummer,X [518],"[518] Hinweis: Wert aus BGM+Z10 DE1004 der ORDERS, mit der die Bestellung erfolgt ist" + 25,Prüfidentifikator,SG1,,,,,,,Muss, + 26,Prüfidentifikator,SG1,RFF,,00012,,,,Muss, + 27,Prüfidentifikator,SG1,RFF,1153,00012,Z13,,Prüfidentifikator,X, + 28,Prüfidentifikator,SG1,RFF,1154,00012,19001,,Bestellbestätigung,, + 29,Prüfidentifikator,SG1,RFF,1154,,19002,,Ablehnung derBestellung,X, + 30,Einzelheiten zu einer Anpassung/Änderung,SG2,,,,,,,Muss, + 31,Einzelheiten zu einer Anpassung/Änderung,SG2,AJT,,00013,,,,Muss, + 32,Einzelheiten zu einer Anpassung/Änderung,SG2,AJT,4465,00013,,,Code des Prüfschritts,X, + 33,Einzelheiten zu einer Anpassung/Änderung,SG2,AJT,1082,00013,G_0061,,Codeliste Gas Nr.G_0061,, + 34,Einzelheiten zu einer Anpassung/Änderung,SG2,AJT,1082,,G_0074S_0067S_0068,,Codeliste Gas Nr.G_0074Codeliste Strom Nr.S_0067Codeliste Strom Nr.S_0068,X [493]X [492],"[492] Wenn MP-ID in NAD+MR (Nachrichtenempfänger) aus Sparte Strom + [493] Wenn MP-ID in NAD+MR (Nachrichtenempfänger) aus Sparte Gas" + 35,MP-ID Absender,SG3,,,,,,,Muss, + 36,MP-ID Absender,SG3,NAD,,00015,,,,Muss, + 37,MP-ID Absender,SG3,NAD,3035,00015,MS,,Dokumenten-/Nachrichtenausstellerbzw. -absender,X, + 38,MP-ID Absender,SG3,NAD,3039,00015,,,MP-ID,X, + 39,MP-ID Absender,SG3,NAD,3055,00015,9,,GS1,X, + 40,MP-ID Absender,SG3,NAD,3055,,293,,"DE, BDEW(Bundesverband derEnergie- undWasserwirtschaft e.V.)",X, + 41,MP-ID Absender,SG3,NAD,3055,,332,,"DE, DVGW Service &Consult GmbH",X, + 42,Ansprechpartner,SG6,,,,,,,Muss, + 43,Ansprechpartner,SG6,CTA,,00016,,,,Muss, + 44,Ansprechpartner,SG6,CTA,3139,00016,IC,,Informationskontakt,X, + 45,Ansprechpartner,SG6,CTA,3412,00016,,,Kontakt,X [500],[500] Hinweis: Angabe eines technischen Ansprechpartners für die Geräteübernahme + 46,Kommunikationsverbindung,SG6,COM,,00017,,,,Muss, + 47,Kommunikationsverbindung,SG6,COM,3148,00017,,,"Kommunikationsadresse,Identifikation",X, + 48,Kommunikationsverbindung,SG6,COM,3155,00017,EM,,Elektronische Post,X [1P0..1], + 49,Kommunikationsverbindung,SG6,COM,3155,,FX,,Telefax,X [1P0..1], + 50,Kommunikationsverbindung,SG6,COM,3155,,TE,,Telefon,X [1P0..1], + 51,Kommunikationsverbindung,SG6,COM,3155,,AJ,,weiteres Telefon,X [1P0..1], + 52,Kommunikationsverbindung,SG6,COM,3155,,AL,,Handy,X [1P0..1], + 53,MP-ID Empfänger,SG3,,,,,,,Muss, + 54,MP-ID Empfänger,SG3,NAD,,00018,,,,Muss, + 55,MP-ID Empfänger,SG3,NAD,3035,00018,MR,,Nachrichtenempfänger,X, + 56,MP-ID Empfänger,SG3,NAD,3039,00018,,,MP-ID,X, + 57,MP-ID Empfänger,SG3,NAD,3055,00018,9,,GS1,X, + 58,MP-ID Empfänger,SG3,NAD,3055,,293,,"DE, BDEW(Bundesverband derEnergie- undWasserwirtschaft e.V.)",X, + 59,MP-ID Empfänger,SG3,NAD,3055,,332,,"DE, DVGW Service &Consult GmbH",X, + 60,Währungsangaben,SG8,,,,,,,, + 61,Währungsangaben,SG8,CUX,,00021,,,,, + 62,Währungsangaben,SG8,CUX,6347,00021,2,,Referenzwährung,, + 63,Währungsangaben,SG8,CUX,6345,00021,EUR,,Euro,, + 64,Währungsangaben,SG8,CUX,6343,00021,9,,Auftragswährung,, + 65,Positionsdaten,SG27,,,,,,,, + 66,Positionsdaten,SG27,LIN,,00022,,,,, + 67,Positionsdaten,SG27,LIN,1082,00022,,,Positionsnummer,,"[911] Format: Mögliche Werte: 1 bis n, je Nachricht oder Segmentgruppe bei 1 beginnend und fortlaufend aufsteigend" + 68,Positionsdaten,SG27,LIN,7140,00022,,,Artikelnummer,,"[19] Es sind nur die Artikelnummern erlaubt, die in der Codeliste der Artikelnummern des BDEW mit dem entsprechenden Prüfidentifikator versehen sind. + [501] Hinweis: Übernahme der Angabe aus der entsprechenden Position der ORDERS" + 69,Positionsdaten,SG27,LIN,7143,00022,Z01,,Artikelnummer,, + 70,Menge,SG27,QTY,,00023,,,,, + 71,Menge,SG27,QTY,6063,00023,145,,Istbestand,, + 72,Menge,SG27,QTY,6060,00023,,,Menge,,[908] Format: Mögliche Werte: 1 bis n + 73,Menge,SG27,QTY,6411,00023,H87,,Stück,, + 74,Positionsnettobetrag,SG27,MOA,,00024,,,,, + 75,Positionsnettobetrag,SG27,MOA,5025,00024,203,,Positionsbetrag (ohneUSt.),, + 76,Positionsnettobetrag,SG27,MOA,5004,00024,,,Geldbetrag,,[930] Format: max. 2 Nachkommastellen + 77,Allgemeine Information (Feld für allgemeine Hinweise),SG27,FTX,,00025,,,,, + 78,Allgemeine Information (Feld für allgemeine Hinweise),SG27,FTX,4451,00025,ACB,,ZusätzlicheInformationen (fürallgemeine Hinweise),, + 79,Allgemeine Information (Feld für allgemeine Hinweise),SG27,FTX,4440,00025,,,Freier Text,, + 80,Preisangaben,SG31,,,,,,,, + 81,Preisangaben,SG31,PRI,,00027,,,,, + 82,Preisangaben,SG31,PRI,5125,00027,CAL,,Berechnungspreis,, + 83,Preisangaben,SG31,PRI,5118,00027,,,"Preis, Betrag",,[912] Format: max. 6 Nachkommastellen + 84,Gerätenummer,SG32,,,,,,,,"[6] Übernahme der Angabe aus der ORDERS, wenn dort vorhanden" + 85,Gerätenummer,SG32,RFF,,00028,,,,, + 86,Gerätenummer,SG32,RFF,1153,00028,Z09,,Gerätenummer,, + 87,Gerätenummer,SG32,RFF,1154,00028,,,Gerätenummer,, + 88,Positionsnummer der Bestellung,SG32,,,,,,,, + 89,Positionsnummer der Bestellung,SG32,RFF,,00029,,,,, + 90,Positionsnummer der Bestellung,SG32,RFF,1153,00029,Z06,,Positionsnummer derBestellung,, + 91,Positionsnummer der Bestellung,SG32,RFF,1154,00029,,,Positionsnummer,,[502] Hinweis: Hinweis: Wert aus LIN DE1082 der ORDERS mit der die Bestellung erfolgt ist + 92,Abschnitts-Kontrollsegment,,UNS,,00030,,,,Muss, + 93,Abschnitts-Kontrollsegment,,UNS,0081,00030,S,,Trennung von Positions-und Summenteil,X, + 94,Summenbetrag (netto),,MOA,,00031,,,,, + 95,Summenbetrag (netto),,MOA,5025,00031,24,,Summe derGesamtkosten,, + 96,Summenbetrag (netto),,MOA,5004,00031,,,Geldbetrag,,"[528] Hinweis: Der Summenbetrag ist entsprechend der Summe der Einzelbeträge der Bestellposition aufzuführen. Bei der Bestellbestätigung kann der Summenbetrag (netto) aus der ORDERS übernommen werden + [930] Format: max. 2 Nachkommastellen" + 97,Nachrichten-Endesegment,,UNT,,00034,,,,Muss, + 98,Nachrichten-Endesegment,,UNT,0074,00034,,,Anzahl der Segmente in einerNachricht,X, + 99,Nachrichten-Endesegment,,UNT,0062,00034,,,Nachrichten-Referenznummer,X, + + ''' +# --- +# name: TestCli.test_kohlrahbi_cli_with_valid_arguments[19007] + ''' + ,Segmentname,Segmentgruppe,Segment,Datenelement,Segment ID,Code,Qualifier,Beschreibung,Bedingungsausdruck,Bedingung + 0,Nachrichten-Kopfsegment,,UNH,,00001,,,,Muss, + 1,Nachrichten-Kopfsegment,,UNH,0062,00001,,,Nachrichten-Referenznummer,X, + 2,Nachrichten-Kopfsegment,,UNH,0065,00001,ORDRSP,,Bestellantwort,X, + 3,Nachrichten-Kopfsegment,,UNH,0052,00001,D,,Entwurfs-Version,X, + 4,Nachrichten-Kopfsegment,,UNH,0054,00001,10A,,Ausgabe 2010 - A,X, + 5,Nachrichten-Kopfsegment,,UNH,0051,00001,UN,,UN/CEFACT,X, + 6,Nachrichten-Kopfsegment,,UNH,0057,00001,1.3,,Versionsnummer derzugrundeliegendenBDEW-Nachrichtenbeschreibung,X, + 7,Beginn der Nachricht,,BGM,,00002,,,,Muss, + 8,Beginn der Nachricht,,BGM,1001,00002,7,,Prozessdatenbericht,X, + 9,Beginn der Nachricht,,BGM,1004,00002,,,Dokumentennummer,X, + 10,Nachrichtendatum,,DTM,,00003,,,,Muss, + 11,Nachrichtendatum,,DTM,2005,00003,137,,Dokumenten-/Nachrichtendatum/-zeit,X, + 12,Nachrichtendatum,,DTM,2380,00003,,,"Datum oder Uhrzeit oderZeitspanne, Wert",X [931] [494],"[494] Das hier genannte Datum muss der Zeitpunkt sein, zu dem das Dokument erstellt wurde, oder ein Zeitpunkt, der davor liegt. + [931] Format: ZZZ = +00" + 13,Nachrichtendatum,,DTM,2379,00003,303,,CCYYMMDDHHMMZZZ,X, + 14,Produkt-/ Leistungsbeschreibung,,IMD,,00008,,,,Muss, + 15,Produkt-/ Leistungsbeschreibung,,IMD,7081,00008,Z13,,Werteermittlung,X, + 16,Referenz Nachrichtennummer,SG1,,,,,,,Muss, + 17,Referenz Nachrichtennummer,SG1,RFF,,00009,,,,Muss, + 18,Referenz Nachrichtennummer,SG1,RFF,1153,00009,ON,,Auftragsnummer (Einkauf),X, + 19,Referenz Nachrichtennummer,SG1,RFF,1154,00009,,,Referenz Nachrichtennummer,X [519],"[519] Hinweis: Wert aus BGM+7 DE1004 der ORDERS, mit der die Bestellung erfolgt ist." + 20,Prüfidentifikator,SG1,,,,,,,Muss, + 21,Prüfidentifikator,SG1,RFF,,00012,,,,Muss, + 22,Prüfidentifikator,SG1,RFF,1153,00012,Z13,,Prüfidentifikator,X, + 23,Prüfidentifikator,SG1,RFF,1154,00012,19007,,Ablehnung AnforderungMesswerte,X, + 24,Einzelheiten zu einer Anpassung/Änderung,SG2,,,,,,,Muss, + 25,Einzelheiten zu einer Anpassung/Änderung,SG2,AJT,,00013,,,,Muss, + 26,Einzelheiten zu einer Anpassung/Änderung,SG2,AJT,4465,00013,,,Code des Prüfschritts,X, + 27,Einzelheiten zu einer Anpassung/Änderung,SG2,AJT,1082,00013,,,,G_0075S_0073S_0074S_0075,"[4] Wenn MP-ID in SG3 NAD+MR mit Rolle LF vorhanden + [14] Wenn MP-ID in SG3 NAD+MR mit Rolle MSB vorhanden + [15] Wenn MP-ID in SG3 NAD+MR mit Rolle NB vorhanden + [492] Wenn MP-ID in NAD+MR (Nachrichtenempfänger) aus Sparte Strom + [493] Wenn MP-ID in NAD+MR (Nachrichtenempfänger) aus Sparte Gas" + 28,MP-ID Absender,SG3,,,,,,,Muss, + 29,MP-ID Absender,SG3,NAD,,00015,,,,Muss, + 30,MP-ID Absender,SG3,NAD,3035,00015,Nachrichtenaussteller bzw.-absender,,,MS, + 31,MP-ID Absender,SG3,NAD,3039,00015,,,MP-ID,X, + 32,MP-ID Absender,SG3,NAD,3055,00015,9,,GS1,X, + 33,MP-ID Absender,SG3,NAD,3055,,293,,"DE, BDEW (Bundesverbandder Energie- undWasserwirtschaft e.V.)",X, + 34,MP-ID Absender,SG3,NAD,3055,,332,,"DE, DVGW Service &Consult GmbH",X, + 35,Ansprechpartner,SG6,,,,,,,Kann, + 36,Ansprechpartner,SG6,CTA,,00016,,,,Muss, + 37,Ansprechpartner,SG6,CTA,3139,00016,,,,IC, + 38,Ansprechpartner,SG6,CTA,3412,00016,,,Kontakt,X, + 39,Kommunikationsverbindung,SG6,COM,,00017,,,,Muss, + 40,Kommunikationsverbindung,SG6,COM,3148,00017,,,"Kommunikationsadresse,Identifikation",X, + 41,Kommunikationsverbindung,SG6,COM,3155,00017,EM,,Elektronische Post,X [1P0..1], + 42,Kommunikationsverbindung,SG6,COM,3155,,FX,,Telefax,X [1P0..1], + 43,Kommunikationsverbindung,SG6,COM,3155,,TE,,Telefon,X [1P0..1], + 44,Kommunikationsverbindung,SG6,COM,3155,,AJ,,weiteres Telefon,X [1P0..1], + 45,Kommunikationsverbindung,SG6,COM,3155,,AL,,Handy,X [1P0..1], + 46,MP-ID Empfänger,SG3,,,,,,,Muss, + 47,MP-ID Empfänger,SG3,NAD,,00018,,,,Muss, + 48,MP-ID Empfänger,SG3,NAD,3035,00018,,,,MR, + 49,MP-ID Empfänger,SG3,NAD,3039,00018,,,MP-ID,X, + 50,MP-ID Empfänger,SG3,NAD,3055,00018,9,,GS1,X, + 51,MP-ID Empfänger,SG3,NAD,3055,,293,,"DE, BDEW (Bundesverbandder Energie- undWasserwirtschaft e.V.)",X, + 52,Abschnitts-Kontrollsegment,,UNS,,00030,,,,Muss, + 53,Abschnitts-Kontrollsegment,,UNS,0081,00030,und Summenteil,,,S, + 54,Nachrichten-Endesegment,,UNT,,00034,,,,Muss, + 55,Nachrichten-Endesegment,,UNT,0074,00034,,,Anzahl der Segmente in einerNachricht,X, + 56,Nachrichten-Endesegment,,UNT,0062,00034,,,Nachrichten-Referenznummer,X, + + ''' +# --- +# name: TestCli.test_kohlrahbi_cli_with_valid_arguments[19016] + ''' + ,Segmentname,Segmentgruppe,Segment,Datenelement,Segment ID,Code,Qualifier,Beschreibung,Bedingungsausdruck,Bedingung + 0,Nachrichten-Kopfsegment,,UNH,,00001,,,,Muss, + 1,Nachrichten-Kopfsegment,,UNH,0062,00001,,,Nachrichten-Referenznummer,X, + 2,Nachrichten-Kopfsegment,,UNH,0065,00001,ORDRSP,,Bestellantwort,X, + 3,Nachrichten-Kopfsegment,,UNH,0052,00001,D,,Entwurfs-Version,X, + 4,Nachrichten-Kopfsegment,,UNH,0054,00001,10A,,Ausgabe 2010 - A,X, + 5,Nachrichten-Kopfsegment,,UNH,0051,00001,UN,,UN/CEFACT,X, + 6,Nachrichten-Kopfsegment,,UNH,0057,00001,1.3,,Versionsnummer derzugrundeliegendenBDEW-Nachrichtenbeschreibung,X, + 7,Beginn der Nachricht,,BGM,,00002,,,,Muss, + 8,Beginn der Nachricht,,BGM,1001,00002,Z13,,Gerätewechselabsicht,X, + 9,Beginn der Nachricht,,BGM,1004,00002,,,Dokumentennummer,X, + 10,Nachrichtendatum,,DTM,,00003,,,,Muss, + 11,Nachrichtendatum,,DTM,2005,00003,137,,Dokumenten-/Nachrichtendatum/-zeit,X, + 12,Nachrichtendatum,,DTM,2380,00003,,,"Datum oder Uhrzeit oderZeitspanne, Wert",X [931] [494],"[494] Das hier genannte Datum muss der Zeitpunkt sein, zu dem das Dokument erstellt wurde, oder ein Zeitpunkt, der davor liegt. + [931] Format: ZZZ = +00" + 13,Nachrichtendatum,,DTM,2379,00003,303,,CCYYMMDDHHMMZZZ,X, + 14,Referenz Nachrichtennummer,SG1,,,,,,,Muss, + 15,Referenz Nachrichtennummer,SG1,RFF,,00009,,,,Muss, + 16,Referenz Nachrichtennummer,SG1,RFF,1153,00009,ON,,Auftragsnummer(Einkauf),X, + 17,Referenz Nachrichtennummer,SG1,RFF,1154,00009,,,Referenz Nachrichtennummer,X [535],"[535] Hinweis: Wert aus BGM+Z13 DE1004 der ORDERS, mit der die Ankündigung Gerätewechselabsicht erfolgt ist." + 18,Prüfidentifikator,SG1,,,,,,,Muss, + 19,Prüfidentifikator,SG1,RFF,,00012,,,,Muss, + 20,Prüfidentifikator,SG1,RFF,1153,00012,Z13,,Prüfidentifikator,X, + 21,Prüfidentifikator,SG1,RFF,1154,00012,19015,,BestätigungGerätewechselabsicht,, + 22,Prüfidentifikator,SG1,RFF,1154,,19016,,AblehnungGerätewechselabsicht,X, + 23,Einzelheiten zu einer Anpassung/Änderung,SG2,,,,,,,Muss, + 24,Einzelheiten zu einer Anpassung/Änderung,SG2,AJT,,00013,,,,Muss, + 25,Einzelheiten zu einer Anpassung/Änderung,SG2,AJT,4465,00013,,,Code des Prüfschritts,X [39],"[38] Möglicher Wert: ZB4 oder ZB5 + [39] Möglicher Wert: E17 oder Z07" + 26,Einzelheiten zu einer Anpassung/Änderung,SG2,AJT,1082,00013,G_0059,,Codeliste Gas Nr.G_0059,X [493], + 27,Einzelheiten zu einer Anpassung/Änderung,SG2,AJT,1082,,G_0060S_0065S_0066,,Codeliste Gas Nr.G_0060Codeliste Strom Nr.S_0065Codeliste Strom Nr.S_0066,X [493]X [492]X [492],"[492] Wenn MP-ID in NAD+MR (Nachrichtenempfänger) aus Sparte Strom + [493] Wenn MP-ID in NAD+MR (Nachrichtenempfänger) aus Sparte Gas" + 28,MP-ID Absender,SG3,,,,,,,Muss, + 29,MP-ID Absender,SG3,NAD,,00015,,,,Muss, + 30,MP-ID Absender,SG3,NAD,3035,00015,MS,,Dokumenten-/Nachrichtenausstellerbzw. -absender,X, + 31,MP-ID Absender,SG3,NAD,3039,00015,,,MP-ID,X, + 32,MP-ID Absender,SG3,NAD,3055,00015,9,,GS1,X, + 33,MP-ID Absender,SG3,NAD,3055,,293,,"DE, BDEW(Bundesverband derEnergie- undWasserwirtschaft e.V.)",X, + 34,MP-ID Absender,SG3,NAD,3055,,332,,"DE, DVGW Service &Consult GmbH",X, + 35,Ansprechpartner,SG6,,,,,,,Kann, + 36,Ansprechpartner,SG6,CTA,,00016,,,,Muss, + 37,Ansprechpartner,SG6,CTA,3139,00016,IC,,Informationskontakt,X, + 38,Ansprechpartner,SG6,CTA,3412,00016,,,Kontakt,X, + 39,Kommunikationsverbindung,SG6,COM,,00017,,,,Muss, + 40,Kommunikationsverbindung,SG6,COM,3148,00017,,,"Kommunikationsadresse,Identifikation",X, + 41,Kommunikationsverbindung,SG6,COM,3155,00017,EM,,Elektronische Post,X [1P0..1], + 42,Kommunikationsverbindung,SG6,COM,3155,,FX,,Telefax,X [1P0..1], + 43,Kommunikationsverbindung,SG6,COM,3155,,TE,,Telefon,X [1P0..1], + 44,Kommunikationsverbindung,SG6,COM,3155,,AJ,,weiteres Telefon,X [1P0..1], + 45,Kommunikationsverbindung,SG6,COM,3155,,AL,,Handy,X [1P0..1], + 46,MP-ID Empfänger,SG3,,,,,,,Muss, + 47,MP-ID Empfänger,SG3,NAD,,00018,,,,Muss, + 48,MP-ID Empfänger,SG3,NAD,3035,00018,MR,,Nachrichtenempfänger,X, + 49,MP-ID Empfänger,SG3,NAD,3039,00018,,,MP-ID,X, + 50,MP-ID Empfänger,SG3,NAD,3055,00018,9,,GS1,X, + 51,MP-ID Empfänger,SG3,NAD,3055,,293,,"DE, BDEW(Bundesverband derEnergie- undWasserwirtschaft e.V.)",X, + 52,Beteiligter Marktpartner MP-ID,SG3,,,,,,,Muss [42],[42] Wenn SG2 AJT+Z07 (Antwortkategorie: Ablehnung (Keine Berechtigung)) vorhanden + 53,Beteiligter Marktpartner MP-ID,SG3,NAD,,00019,,,,Muss, + 54,Beteiligter Marktpartner MP-ID,SG3,NAD,3035,00019,VY,,andere zugehörige Partei,X, + 55,Beteiligter Marktpartner MP-ID,SG3,NAD,3039,00019,,,MP-ID,X [536],"[536] Hinweis: Es ist die MP-ID des Eigentümers (MSB) zur bilateralen Klärung anzugeben, wenn der angefragte MSB nicht selber der Eigentümer ist." + 56,Beteiligter Marktpartner MP-ID,SG3,NAD,3055,00019,9,,GS1,X, + 57,Beteiligter Marktpartner MP-ID,SG3,NAD,3055,,293,,"DE, BDEW(Bundesverband derEnergie- undWasserwirtschaft e.V.)",X, + 58,Beteiligter Marktpartner MP-ID,SG3,NAD,3055,,332,,"DE, DVGW Service &Consult GmbH",X, + 59,Name und Lieferadresse für Altgeräte,SG3,,,,,,,,[41] wenn SG2 AJT (Einzelheiten zu einer Anpassung/Änderung) DE4465 mit Wert ZB5 vorhanden + 60,Name und Lieferadresse für Altgeräte,SG3,NAD,,00020,,,,, + 61,Name und Lieferadresse für Altgeräte,SG3,NAD,3035,00020,Z22,,Lieferadresse fürAltgeräte,, + 62,Name und Lieferadresse für Altgeräte,SG3,NAD,3036,00020,,,Beteiligter,, + 63,Name und Lieferadresse für Altgeräte,SG3,NAD,3045,00020,Z02,,Struktur derFirmenbezeichnung,, + 64,Name und Lieferadresse für Altgeräte,SG3,NAD,3042,00020,,,Straße und Hausnummer oderPostfach,, + 65,Name und Lieferadresse für Altgeräte,SG3,NAD,3164,00020,,,Ort,, + 66,Name und Lieferadresse für Altgeräte,SG3,NAD,3251,00020,,,"Postleitzahl, Code",,"[34] wenn vorhanden + [40] Wenn der Code im DE3207 in der ""EDI@Energy Codeliste der europäischen Ländercodes"" in der Spalte ""PLZ vorhanden"" ein ""X"" enthält" + 67,Name und Lieferadresse für Altgeräte,SG3,NAD,3207,00020,,,"Ländername, Code",, + 68,Abschnitts-Kontrollsegment,,UNS,,00030,,,,Muss, + 69,Abschnitts-Kontrollsegment,,UNS,0081,00030,S,,Trennung von Positions-und Summenteil,X, + 70,Nachrichten-Endesegment,,UNT,,00034,,,,Muss, + 71,Nachrichten-Endesegment,,UNT,0074,00034,,,Anzahl der Segmente in einerNachricht,X, + 72,Nachrichten-Endesegment,,UNT,0062,00034,,,Nachrichten-Referenznummer,X, + + ''' +# --- +# name: TestCli.test_kohlrahbi_cli_with_valid_arguments[19103] + ''' + ,Segmentname,Segmentgruppe,Segment,Datenelement,Segment ID,Code,Qualifier,Beschreibung,Bedingungsausdruck,Bedingung + 0,Nachrichten-Kopfsegment,,UNH,,00001,,,,Muss, + 1,Nachrichten-Kopfsegment,,UNH,0062,00001,,,Nachrichten-Referenznummer,X, + 2,Nachrichten-Kopfsegment,,UNH,0065,00001,ORDRSP,,Bestellantwort,X, + 3,Nachrichten-Kopfsegment,,UNH,0052,00001,D,,Entwurfs-Version,X, + 4,Nachrichten-Kopfsegment,,UNH,0054,00001,10A,,Ausgabe 2010 - A,X, + 5,Nachrichten-Kopfsegment,,UNH,0051,00001,UN,,UN/CEFACT,X, + 6,Nachrichten-Kopfsegment,,UNH,0057,00001,1.3,,Versionsnummer derzugrundeliegendenBDEW-Nachrichtenbeschreibung,X, + 7,Beginn der Nachricht,,BGM,,00002,,,,Muss, + 8,Beginn der Nachricht,,BGM,1001,00002,7,,Prozessdatenbericht,X, + 9,Beginn der Nachricht,,BGM,1004,00002,,,Dokumentennummer,X, + 10,Nachrichtendatum,,DTM,,00003,,,,Muss, + 11,Nachrichtendatum,,DTM,2005,00003,137,,Dokumenten-/Nachrichtendatum/-zeit,X, + 12,Nachrichtendatum,,DTM,2380,00003,,,"Datum oder Uhrzeit oderZeitspanne, Wert",X [931] [494],"[494] Das hier genannte Datum muss der Zeitpunkt sein, zu dem das Dokument erstellt wurde, oder ein Zeitpunkt, der davor liegt. + [931] Format: ZZZ = +00" + 13,Nachrichtendatum,,DTM,2379,00003,303,,CCYYMMDDHHMMZZZ,X, + 14,Produkt-/ Leistungsbeschreibung,,IMD,,00008,,,,Muss, + 15,Produkt-/ Leistungsbeschreibung,,IMD,7081,00008,Z10,,Abrechnungsbrennwertund Zustandszahl,X, + 16,Referenz Nachrichtennummer,SG1,,,,,,,Muss, + 17,Referenz Nachrichtennummer,SG1,RFF,,00009,,,,Muss, + 18,Referenz Nachrichtennummer,SG1,RFF,1153,00009,ON,,Auftragsnummer (Einkauf),X, + 19,Referenz Nachrichtennummer,SG1,RFF,1154,00009,,,Referenz Nachrichtennummer,X [523],"[523] Hinweis: Wert aus BGM+7 DE1004 der ORDERS, mit der die Anforderung Anforderung von Brennwert und Zustandszahl erfolgt ist." + 20,Prüfidentifikator,SG1,,,,,,,Muss, + 21,Prüfidentifikator,SG1,RFF,,00012,,,,Muss, + 22,Prüfidentifikator,SG1,RFF,1153,00012,Z13,,Prüfidentifikator,X, + 23,Prüfidentifikator,SG1,RFF,1154,00012,19103,,Ablehnung Brennwert undZustandszahl,X, + 24,Einzelheiten zu einer Anpassung/Änderung,SG2,,,,,,,Muss, + 25,Einzelheiten zu einer Anpassung/Änderung,SG2,AJT,,00013,,,,Muss, + 26,Einzelheiten zu einer Anpassung/Änderung,SG2,AJT,4465,00013,,,Code des Prüfschritts,X, + 27,Einzelheiten zu einer Anpassung/Änderung,SG2,AJT,1082,00013,,,,G_0015, + 28,MP-ID Absender,SG3,,,,,,,Muss, + 29,MP-ID Absender,SG3,NAD,,00015,,,,Muss, + 30,MP-ID Absender,SG3,NAD,3035,00015,Nachrichtenaussteller bzw.-absender,,,MS, + 31,MP-ID Absender,SG3,NAD,3039,00015,,,MP-ID,X [29],[29] MP-ID nur aus Sparte Gas + 32,MP-ID Absender,SG3,NAD,3055,00015,9,,GS1,X, + 33,MP-ID Absender,SG3,NAD,3055,,332,,"DE, DVGW Service &Consult GmbH",X, + 34,Ansprechpartner,SG6,,,,,,,Kann, + 35,Ansprechpartner,SG6,CTA,,00016,,,,Muss, + 36,Ansprechpartner,SG6,CTA,3139,00016,,,,IC, + 37,Ansprechpartner,SG6,CTA,3412,00016,,,Kontakt,X, + 38,Kommunikationsverbindung,SG6,COM,,00017,,,,Muss, + 39,Kommunikationsverbindung,SG6,COM,3148,00017,,,"Kommunikationsadresse,Identifikation",X, + 40,Kommunikationsverbindung,SG6,COM,3155,00017,EM,,Elektronische Post,X [1P0..1], + 41,Kommunikationsverbindung,SG6,COM,3155,,FX,,Telefax,X [1P0..1], + 42,Kommunikationsverbindung,SG6,COM,3155,,TE,,Telefon,X [1P0..1], + 43,Kommunikationsverbindung,SG6,COM,3155,,AJ,,weiteres Telefon,X [1P0..1], + 44,Kommunikationsverbindung,SG6,COM,3155,,AL,,Handy,X [1P0..1], + 45,MP-ID Empfänger,SG3,,,,,,,Muss, + 46,MP-ID Empfänger,SG3,NAD,,00018,,,,Muss, + 47,MP-ID Empfänger,SG3,NAD,3035,00018,,,,MR, + 48,MP-ID Empfänger,SG3,NAD,3039,00018,,,MP-ID,X [29],[29] MP-ID nur aus Sparte Gas + 49,MP-ID Empfänger,SG3,NAD,3055,00018,9,,GS1,X, + 50,MP-ID Empfänger,SG3,NAD,3055,,332,,"DE, DVGW Service &Consult GmbH",X, + 51,Abschnitts-Kontrollsegment,,UNS,,00030,,,,Muss, + 52,Abschnitts-Kontrollsegment,,UNS,0081,00030,und Summenteil,,,S, + 53,Nachrichten-Endesegment,,UNT,,00034,,,,Muss, + 54,Nachrichten-Endesegment,,UNT,0074,00034,,,Anzahl der Segmente in einerNachricht,X, + 55,Nachrichten-Endesegment,,UNT,0062,00034,,,Nachrichten-Referenznummer,X, + + ''' +# --- +# name: TestCli.test_kohlrahbi_cli_with_valid_arguments[19120] + ''' + ,Segmentname,Segmentgruppe,Segment,Datenelement,Segment ID,Code,Qualifier,Beschreibung,Bedingungsausdruck,Bedingung + 0,Nachrichten-Kopfsegment,,UNH,,00001,,,,Muss, + 1,Nachrichten-Kopfsegment,,UNH,0062,00001,,,Nachrichten-Referenznummer,X, + 2,Nachrichten-Kopfsegment,,UNH,0065,00001,ORDRSP,,Bestellantwort,X, + 3,Nachrichten-Kopfsegment,,UNH,0052,00001,D,,Entwurfs-Version,X, + 4,Nachrichten-Kopfsegment,,UNH,0054,00001,10A,,Ausgabe 2010 - A,X, + 5,Nachrichten-Kopfsegment,,UNH,0051,00001,UN,,UN/CEFACT,X, + 6,Nachrichten-Kopfsegment,,UNH,0057,00001,1.3,,Versionsnummer derzugrundeliegendenBDEW-Nachrichtenbeschreibung,X, + 7,Beginn der Nachricht,,BGM,,00002,,,,Muss, + 8,Beginn der Nachricht,,BGM,1001,00002,Z68,,Änderung,X, + 9,Beginn der Nachricht,,BGM,1004,00002,,,Dokumentennummer,X, + 10,Nachrichtendatum,,DTM,,00003,,,,Muss, + 11,Nachrichtendatum,,DTM,2005,00003,137,,Dokumenten-/Nachrichtendatum/-zeit,X, + 12,Nachrichtendatum,,DTM,2380,00003,,,"Datum oder Uhrzeit oderZeitspanne, Wert",X [931] [494],"[494] Das hier genannte Datum muss der Zeitpunkt sein, zu dem das Dokument erstellt wurde, oder ein Zeitpunkt, der davor liegt. + [931] Format: ZZZ = +00" + 13,Nachrichtendatum,,DTM,2379,00003,303,,CCYYMMDDHHMMZZZ,X, + 14,Referenz Nachrichtennummer,SG1,,,,,,,Muss, + 15,Referenz Nachrichtennummer,SG1,RFF,,00009,,,,Muss, + 16,Referenz Nachrichtennummer,SG1,RFF,1153,00009,ON,,Auftragsnummer (Einkauf),X, + 17,Referenz Nachrichtennummer,SG1,RFF,1154,00009,,,Referenz Nachrichtennummer,X [529],[529] Hinweis: Dokumentennummer aus BGM DE1004 der ORDERS + 18,Prüfidentifikator,SG1,,,,,,,Muss, + 19,Prüfidentifikator,SG1,RFF,,00012,,,,Muss, + 20,Prüfidentifikator,SG1,RFF,1153,00012,Z13,,Prüfidentifikator,X, + 21,Prüfidentifikator,SG1,RFF,1154,00012,19120,,Mitteilung zur Änderung,X, + 22,Einzelheiten zu einer Anpassung/Änderung,SG2,,,,,,,Muss, + 23,Einzelheiten zu einer Anpassung/Änderung,SG2,AJT,,00013,,,,Muss, + 24,Einzelheiten zu einer Anpassung/Änderung,SG2,AJT,4465,00013,,,Code des Prüfschritts,X, + 25,Einzelheiten zu einer Anpassung/Änderung,SG2,AJT,1082,00013,,,,E_0526, + 26,Allgemeine Information (Feld für allgemeine Hinweise),SG2,FTX,,00014,,,,Muss [28],[28] Wenn AJT+A99 vorhanden + 27,Allgemeine Information (Feld für allgemeine Hinweise),SG2,FTX,4451,00014,,,,AAP, + 28,Allgemeine Information (Feld für allgemeine Hinweise),SG2,FTX,4440,00014,,,Freier Text,X, + 29,MP-ID Absender,SG3,,,,,,,Muss, + 30,MP-ID Absender,SG3,NAD,,00015,,,,Muss, + 31,MP-ID Absender,SG3,NAD,3035,00015,Nachrichtenaussteller bzw.-absender,,,MS, + 32,MP-ID Absender,SG3,NAD,3039,00015,,,MP-ID,X [30],[30] MP-ID nur aus Sparte Strom + 33,MP-ID Absender,SG3,NAD,3055,00015,9,,GS1,X, + 34,MP-ID Absender,SG3,NAD,3055,,293,,"DE, BDEW (Bundesverbandder Energie- undWasserwirtschaft e.V.)",X, + 35,Ansprechpartner,SG6,,,,,,,Kann, + 36,Ansprechpartner,SG6,CTA,,00016,,,,Muss, + 37,Ansprechpartner,SG6,CTA,3139,00016,,,,IC, + 38,Ansprechpartner,SG6,CTA,3412,00016,,,Kontakt,X, + 39,Kommunikationsverbindung,SG6,COM,,00017,,,,Muss, + 40,Kommunikationsverbindung,SG6,COM,3148,00017,,,"Kommunikationsadresse,Identifikation",X, + 41,Kommunikationsverbindung,SG6,COM,3155,00017,EM,,Elektronische Post,X [1P0..1], + 42,Kommunikationsverbindung,SG6,COM,3155,,FX,,Telefax,X [1P0..1], + 43,Kommunikationsverbindung,SG6,COM,3155,,TE,,Telefon,X [1P0..1], + 44,Kommunikationsverbindung,SG6,COM,3155,,AJ,,weiteres Telefon,X [1P0..1], + 45,Kommunikationsverbindung,SG6,COM,3155,,AL,,Handy,X [1P0..1], + 46,MP-ID Empfänger,SG3,,,,,,,Muss, + 47,MP-ID Empfänger,SG3,NAD,,00018,,,,Muss, + 48,MP-ID Empfänger,SG3,NAD,3035,00018,,,,MR, + 49,MP-ID Empfänger,SG3,NAD,3039,00018,,,MP-ID,X [30],[30] MP-ID nur aus Sparte Strom + 50,MP-ID Empfänger,SG3,NAD,3055,00018,9,,GS1,X, + 51,MP-ID Empfänger,SG3,NAD,3055,,293,,"DE, BDEW (Bundesverbandder Energie- undWasserwirtschaft e.V.)",X, + 52,Abschnitts-Kontrollsegment,,UNS,,00030,,,,Muss, + 53,Abschnitts-Kontrollsegment,,UNS,0081,00030,und Summenteil,,,S, + 54,Nachrichten-Endesegment,,UNT,,00034,,,,Muss, + 55,Nachrichten-Endesegment,,UNT,0074,00034,,,Anzahl der Segmente in einerNachricht,X, + 56,Nachrichten-Endesegment,,UNT,0062,00034,,,Nachrichten-Referenznummer,X, + + ''' +# --- +# name: TestCli.test_kohlrahbi_cli_with_valid_arguments[19131] + ''' + ,Segmentname,Segmentgruppe,Segment,Datenelement,Segment ID,Code,Qualifier,Beschreibung,Bedingungsausdruck,Bedingung + 0,Nachrichten-Kopfsegment,,UNH,,00001,,,,Muss, + 1,Nachrichten-Kopfsegment,,UNH,0062,00001,,,Nachrichten-Referenznummer,X, + 2,Nachrichten-Kopfsegment,,UNH,0065,00001,ORDRSP,,Bestellantwort,X, + 3,Nachrichten-Kopfsegment,,UNH,0052,00001,D,,Entwurfs-Version,X, + 4,Nachrichten-Kopfsegment,,UNH,0054,00001,10A,,Ausgabe 2010 - A,X, + 5,Nachrichten-Kopfsegment,,UNH,0051,00001,UN,,UN/CEFACT,X, + 6,Nachrichten-Kopfsegment,,UNH,0057,00001,1.3,,Versionsnummer derzugrundeliegendenBDEW-Nachrichtenbeschreibung,X, + 7,Beginn der Nachricht,,BGM,,00002,,,,Muss, + 8,Beginn der Nachricht,,BGM,1001,00002,Z72,,Beendigung einerKonfiguration,X, + 9,Beginn der Nachricht,,BGM,1004,00002,,,Dokumentennummer,X, + 10,Nachrichtendatum,,DTM,,00003,,,,Muss, + 11,Nachrichtendatum,,DTM,2005,00003,137,,Dokumenten-/Nachrichtendatum/-zeit,X, + 12,Nachrichtendatum,,DTM,2380,00003,,,"Datum oder Uhrzeit oderZeitspanne, Wert",X [931] [494],"[494] Das hier genannte Datum muss der Zeitpunkt sein, zu dem das Dokument erstellt wurde, oder ein Zeitpunkt, der davor liegt. + [931] Format: ZZZ = +00" + 13,Nachrichtendatum,,DTM,2379,00003,303,,CCYYMMDDHHMMZZZ,X, + 14,Referenz Nachrichtennummer,SG1,,,,,,,Muss, + 15,Referenz Nachrichtennummer,SG1,RFF,,00009,,,,Muss, + 16,Referenz Nachrichtennummer,SG1,RFF,1153,00009,ON,,Auftragsnummer (Einkauf),X, + 17,Referenz Nachrichtennummer,SG1,RFF,1154,00009,,,Referenz Nachrichtennummer,X [537],"[537] Hinweis: Wert aus BGM+Z72 DE1004 der ORDERS, mit der die Bestellung Beendigung der Konfiguration erfolgt ist." + 18,Prüfidentifikator,SG1,,,,,,,Muss, + 19,Prüfidentifikator,SG1,RFF,,00012,,,,Muss, + 20,Prüfidentifikator,SG1,RFF,1153,00012,Z13,,Prüfidentifikator,X, + 21,Prüfidentifikator,SG1,RFF,1154,00012,19131,,Antwort auf BestellungBeendigung einerKonfiguration,X, + 22,Einzelheiten zu einer Anpassung/Änderung,SG2,,,,,,,Muss, + 23,Einzelheiten zu einer Anpassung/Änderung,SG2,AJT,,00013,,,,Muss, + 24,Einzelheiten zu einer Anpassung/Änderung,SG2,AJT,4465,00013,,,Code des Prüfschritts,X, + 25,Einzelheiten zu einer Anpassung/Änderung,SG2,AJT,1082,00013,,,,E_0538E_0539,[4] Wenn MP-ID in SG3 NAD+MR mit Rolle LF vorhanden + 26,Allgemeine Information (Feld für allgemeine Hinweise),SG2,FTX,,00014,,,,Muss [28],[28] Wenn AJT+A99 vorhanden + 27,Allgemeine Information (Feld für allgemeine Hinweise),SG2,FTX,4451,00014,,,,AAP, + 28,Allgemeine Information (Feld für allgemeine Hinweise),SG2,FTX,4440,00014,,,Freier Text,X, + 29,MP-ID Absender,SG3,,,,,,,Muss, + 30,MP-ID Absender,SG3,NAD,,00015,,,,Muss, + 31,MP-ID Absender,SG3,NAD,3035,00015,Nachrichtenaussteller bzw.-absender,,,MS, + 32,MP-ID Absender,SG3,NAD,3039,00015,,,MP-ID,X [30],[30] MP-ID nur aus Sparte Strom + 33,MP-ID Absender,SG3,NAD,3055,00015,9,,GS1,X, + 34,MP-ID Absender,SG3,NAD,3055,,293,,"DE, BDEW (Bundesverbandder Energie- undWasserwirtschaft e.V.)",X, + 35,Ansprechpartner,SG6,,,,,,,Kann, + 36,Ansprechpartner,SG6,CTA,,00016,,,,Muss, + 37,Ansprechpartner,SG6,CTA,3139,00016,,,,IC, + 38,Ansprechpartner,SG6,CTA,3412,00016,,,Kontakt,X, + 39,Kommunikationsverbindung,SG6,COM,,00017,,,,Muss, + 40,Kommunikationsverbindung,SG6,COM,3148,00017,,,"Kommunikationsadresse,Identifikation",X, + 41,Kommunikationsverbindung,SG6,COM,3155,00017,EM,,Elektronische Post,X [1P0..1], + 42,Kommunikationsverbindung,SG6,COM,3155,,FX,,Telefax,X [1P0..1], + 43,Kommunikationsverbindung,SG6,COM,3155,,TE,,Telefon,X [1P0..1], + 44,Kommunikationsverbindung,SG6,COM,3155,,AJ,,weiteres Telefon,X [1P0..1], + 45,Kommunikationsverbindung,SG6,COM,3155,,AL,,Handy,X [1P0..1], + 46,MP-ID Empfänger,SG3,,,,,,,Muss, + 47,MP-ID Empfänger,SG3,NAD,,00018,,,,Muss, + 48,MP-ID Empfänger,SG3,NAD,3035,00018,,,,MR, + 49,MP-ID Empfänger,SG3,NAD,3039,00018,,,MP-ID,X [30],[30] MP-ID nur aus Sparte Strom + 50,MP-ID Empfänger,SG3,NAD,3055,00018,9,,GS1,X, + 51,MP-ID Empfänger,SG3,NAD,3055,,293,,"DE, BDEW (Bundesverbandder Energie- undWasserwirtschaft e.V.)",X, + 52,Abschnitts-Kontrollsegment,,UNS,,00030,,,,Muss, + 53,Abschnitts-Kontrollsegment,,UNS,0081,00030,und Summenteil,,,S, + 54,Nachrichten-Endesegment,,UNT,,00034,,,,Muss, + 55,Nachrichten-Endesegment,,UNT,0074,00034,,,Anzahl der Segmente in einerNachricht,X, + 56,Nachrichten-Endesegment,,UNT,0062,00034,,,Nachrichten-Referenznummer,X, + + ''' +# --- +# name: TestCli.test_kohlrahbi_cli_with_valid_arguments[19204] + ''' + ,Segmentname,Segmentgruppe,Segment,Datenelement,Segment ID,Code,Qualifier,Beschreibung,Bedingungsausdruck,Bedingung + 0,Nachrichten-Kopfsegment,,UNH,,00001,,,,Muss, + 1,Nachrichten-Kopfsegment,,UNH,0062,00001,,,Nachrichten-Referenznummer,X, + 2,Nachrichten-Kopfsegment,,UNH,0065,00001,ORDRSP,,Bestellantwort,X, + 3,Nachrichten-Kopfsegment,,UNH,0052,00001,D,,Entwurfs-Version,X, + 4,Nachrichten-Kopfsegment,,UNH,0054,00001,10A,,Ausgabe 2010 - A,X, + 5,Nachrichten-Kopfsegment,,UNH,0051,00001,UN,,UN/CEFACT,X, + 6,Nachrichten-Kopfsegment,,UNH,0057,00001,1.3,,Versionsnummer derzugrundeliegendenBDEW-Nachrichtenbeschreibung,X, + 7,Beginn der Nachricht,,BGM,,00002,,,,Muss, + 8,Beginn der Nachricht,,BGM,1001,00002,BK,,Zeitreihen im Rahmen derBilanzkreisabrechnung,X, + 9,Beginn der Nachricht,,BGM,1004,00002,,,Dokumentennummer,X, + 10,Nachrichtendatum,,DTM,,00003,,,,Muss, + 11,Nachrichtendatum,,DTM,2005,00003,137,,Dokumenten-/Nachrichtendatum/-zeit,X, + 12,Nachrichtendatum,,DTM,2380,00003,,,"Datum oder Uhrzeit oderZeitspanne, Wert",X [931] [494],"[494] Das hier genannte Datum muss der Zeitpunkt sein, zu dem das Dokument erstellt wurde, oder ein Zeitpunkt, der davor liegt. + [931] Format: ZZZ = +00" + 13,Nachrichtendatum,,DTM,2379,00003,303,,CCYYMMDDHHMMZZZ,X, + 14,Referenz Nachrichtennummer,SG1,,,,,,,Muss, + 15,Referenz Nachrichtennummer,SG1,RFF,,00009,,,,Muss, + 16,Referenz Nachrichtennummer,SG1,RFF,1153,00009,ON,,Auftragsnummer (Einkauf),X, + 17,Referenz Nachrichtennummer,SG1,RFF,1154,00009,,,Referenz Nachrichtennummer,X, + 18,Prüfidentifikator,SG1,,,,,,,Muss, + 19,Prüfidentifikator,SG1,RFF,,00012,,,,Muss, + 20,Prüfidentifikator,SG1,RFF,1153,00012,Z13,,Prüfidentifikator,X, + 21,Prüfidentifikator,SG1,RFF,1154,00012,19204,,Ablehnung Ab-/Bestellungder Aggregationsebene,X, + 22,Einzelheiten zu einer Anpassung/Änderung,SG2,,,,,,,Muss, + 23,Einzelheiten zu einer Anpassung/Änderung,SG2,AJT,,00013,,,,Muss, + 24,Einzelheiten zu einer Anpassung/Änderung,SG2,AJT,4465,00013,,,Code des Prüfschritts,X, + 25,Einzelheiten zu einer Anpassung/Änderung,SG2,AJT,1082,00013,,,,E_0003E_0022, + 26,MP-ID Absender,SG3,,,,,,,Muss, + 27,MP-ID Absender,SG3,NAD,,00015,,,,Muss, + 28,MP-ID Absender,SG3,NAD,3035,00015,Nachrichtenaussteller bzw.-absender,,,MS, + 29,MP-ID Absender,SG3,NAD,3039,00015,,,MP-ID,X [30],[30] MP-ID nur aus Sparte Strom + 30,MP-ID Absender,SG3,NAD,3055,00015,9,,GS1,X, + 31,MP-ID Absender,SG3,NAD,3055,,293,,"DE, BDEW (Bundesverbandder Energie- undWasserwirtschaft e.V.)",X, + 32,Ansprechpartner,SG6,,,,,,,Kann, + 33,Ansprechpartner,SG6,CTA,,00016,,,,Muss, + 34,Ansprechpartner,SG6,CTA,3139,00016,,,,IC, + 35,Ansprechpartner,SG6,CTA,3412,00016,,,Kontakt,X, + 36,Kommunikationsverbindung,SG6,COM,,00017,,,,Muss, + 37,Kommunikationsverbindung,SG6,COM,3148,00017,,,"Kommunikationsadresse,Identifikation",X, + 38,Kommunikationsverbindung,SG6,COM,3155,00017,EM,,Elektronische Post,X [1P0..1], + 39,Kommunikationsverbindung,SG6,COM,3155,,FX,,Telefax,X [1P0..1], + 40,Kommunikationsverbindung,SG6,COM,3155,,TE,,Telefon,X [1P0..1], + 41,Kommunikationsverbindung,SG6,COM,3155,,AJ,,weiteres Telefon,X [1P0..1], + 42,Kommunikationsverbindung,SG6,COM,3155,,AL,,Handy,X [1P0..1], + 43,MP-ID Empfänger,SG3,,,,,,,Muss, + 44,MP-ID Empfänger,SG3,NAD,,00018,,,,Muss, + 45,MP-ID Empfänger,SG3,NAD,3035,00018,,,,MR, + 46,MP-ID Empfänger,SG3,NAD,3039,00018,,,MP-ID,X [30],[30] MP-ID nur aus Sparte Strom + 47,MP-ID Empfänger,SG3,NAD,3055,00018,9,,GS1,X, + 48,MP-ID Empfänger,SG3,NAD,3055,,293,,"DE, BDEW (Bundesverbandder Energie- undWasserwirtschaft e.V.)",X, + 49,Abschnitts-Kontrollsegment,,UNS,,00030,,,,Muss, + 50,Abschnitts-Kontrollsegment,,UNS,0081,00030,und Summenteil,,,S, + 51,Nachrichten-Endesegment,,UNT,,00034,,,,Muss, + 52,Nachrichten-Endesegment,,UNT,0074,00034,,,Anzahl der Segmente in einerNachricht,X, + 53,Nachrichten-Endesegment,,UNT,0062,00034,,,Nachrichten-Referenznummer,X, + + ''' +# --- +# name: TestCli.test_kohlrahbi_cli_with_valid_arguments[19301] + ''' + ,Segmentname,Segmentgruppe,Segment,Datenelement,Segment ID,Code,Qualifier,Beschreibung,Bedingungsausdruck,Bedingung + 0,Nachrichten-Kopfsegment,,UNH,,00001,,,,Muss, + 1,Nachrichten-Kopfsegment,,UNH,0062,00001,,,Nachrichten-Referenznummer,X, + 2,Nachrichten-Kopfsegment,,UNH,0065,00001,ORDRSP,,Bestellantwort,X, + 3,Nachrichten-Kopfsegment,,UNH,0052,00001,D,,Entwurfs-Version,X, + 4,Nachrichten-Kopfsegment,,UNH,0054,00001,10A,,Ausgabe 2010 - A,X, + 5,Nachrichten-Kopfsegment,,UNH,0051,00001,UN,,UN/CEFACT,X, + 6,Nachrichten-Kopfsegment,,UNH,0057,00001,1.3,,Versionsnummer derzugrundeliegendenBDEW-Nachrichtenbeschreibung,X, + 7,Beginn der Nachricht,,BGM,,00002,,,,Muss, + 8,Beginn der Nachricht,,BGM,1001,00002,7,,Prozessdatenbericht,X, + 9,Beginn der Nachricht,,BGM,1001,,Z14,,Stammdaten der Markt-oder Messlokation,X, + 10,Beginn der Nachricht,,BGM,1004,00002,,,Dokumentennummer,X, + 11,Nachrichtendatum,,DTM,,00003,,,,Muss, + 12,Nachrichtendatum,,DTM,2005,00003,137,,Dokumenten-/Nachrichtendatum/-zeit,X, + 13,Nachrichtendatum,,DTM,2380,00003,,,"Datum oder Uhrzeit oderZeitspanne, Wert",X [931] [494],"[494] Das hier genannte Datum muss der Zeitpunkt sein, zu dem das Dokument erstellt wurde, oder ein Zeitpunkt, der davor liegt. + [931] Format: ZZZ = +00" + 14,Nachrichtendatum,,DTM,2379,00003,303,,CCYYMMDDHHMMZZZ,X, + 15,Abonnement,,IMD,,00007,,,,Muss, + 16,Abonnement,,IMD,7081,00007,Z01,,Start Abo,X, + 17,Abonnement,,IMD,7081,,Z02,,Ende Abo,X, + 18,Produkt-/ Leistungsbeschreibung,,IMD,,00008,,,,Muss [1],[1] Wenn BGM+7 vorhanden + 19,Produkt-/ Leistungsbeschreibung,,IMD,7081,00008,Z11,,Lastgangdaten,X, + 20,Produkt-/ Leistungsbeschreibung,,IMD,7081,,Z12,,Zählerstände,X, + 21,Referenz Nachrichtennummer,SG1,,,,,,,Muss, + 22,Referenz Nachrichtennummer,SG1,RFF,,00009,,,,Muss, + 23,Referenz Nachrichtennummer,SG1,RFF,1153,00009,ON,,Auftragsnummer(Einkauf),X, + 24,Referenz Nachrichtennummer,SG1,RFF,1154,00009,,,Referenz Nachrichtennummer,X, + 25,Prüfidentifikator,SG1,,,,,,,Muss, + 26,Prüfidentifikator,SG1,RFF,,00012,,,,Muss, + 27,Prüfidentifikator,SG1,RFF,1153,00012,Z13,,Prüfidentifikator,X, + 28,Prüfidentifikator,SG1,RFF,1154,00012,19301,,Ablehnung Abo,X, + 29,Prüfidentifikator,SG1,RFF,1154,,19302,,Bestätigung Ende Abo,, + 30,Einzelheiten zu einer Anpassung/Änderung,SG2,,,,,,,Muss, + 31,Einzelheiten zu einer Anpassung/Änderung,SG2,AJT,,00013,,,,Muss, + 32,Einzelheiten zu einer Anpassung/Änderung,SG2,AJT,4465,00013,,,Code des Prüfschritts,X, + 33,Einzelheiten zu einer Anpassung/Änderung,SG2,AJT,1082,00013,Codeliste Strom Nr.S_0092Codeliste Strom Nr.S_0093,,S_0092S_0093,X, + 34,MP-ID Absender,SG3,,,,,,,Muss, + 35,MP-ID Absender,SG3,NAD,,00015,,,,Muss, + 36,MP-ID Absender,SG3,NAD,3035,00015,MS,,Dokumenten-/Nachrichtenausstellerbzw. -absender,X, + 37,MP-ID Absender,SG3,NAD,3039,00015,,,MP-ID,X [30],[30] MP-ID nur aus Sparte Strom + 38,MP-ID Absender,SG3,NAD,3055,00015,9,,GS1,X, + 39,MP-ID Absender,SG3,NAD,3055,,293,,"DE, BDEW(Bundesverband derEnergie- undWasserwirtschaft e.V.)",X, + 40,Ansprechpartner,SG6,,,,,,,Muss, + 41,Ansprechpartner,SG6,CTA,,00016,,,,Muss, + 42,Ansprechpartner,SG6,CTA,3139,00016,IC,,Informationskontakt,X, + 43,Ansprechpartner,SG6,CTA,3412,00016,,,Kontakt,X, + 44,Kommunikationsverbindung,SG6,COM,,00017,,,,Muss, + 45,Kommunikationsverbindung,SG6,COM,3148,00017,,,"Kommunikationsadresse,Identifikation",X, + 46,Kommunikationsverbindung,SG6,COM,3155,00017,EM,,Elektronische Post,X [1P0..1], + 47,Kommunikationsverbindung,SG6,COM,3155,,FX,,Telefax,X [1P0..1], + 48,Kommunikationsverbindung,SG6,COM,3155,,TE,,Telefon,X [1P0..1], + 49,Kommunikationsverbindung,SG6,COM,3155,,AJ,,weiteres Telefon,X [1P0..1], + 50,Kommunikationsverbindung,SG6,COM,3155,,AL,,Handy,X [1P0..1], + 51,MP-ID Empfänger,SG3,,,,,,,Muss, + 52,MP-ID Empfänger,SG3,NAD,,00018,,,,Muss, + 53,MP-ID Empfänger,SG3,NAD,3035,00018,MR,,Nachrichtenempfänger,X, + 54,MP-ID Empfänger,SG3,NAD,3039,00018,,,MP-ID,X [30],[30] MP-ID nur aus Sparte + 55,MP-ID Empfänger,SG3,NAD,3055,00018,9,,GS1,X, + 56,MP-ID Empfänger,SG3,NAD,3055,,293,,"DE, BDEW(Bundesverband derEnergie- undWasserwirtschaft e.V.)",X, + 57,Abschnitts-Kontrollsegment,,UNS,,00030,,,,Muss, + 58,Abschnitts-Kontrollsegment,,UNS,0081,00030,S,,Trennung von Positions-und Summenteil,X, + 59,Nachrichten-Endesegment,,UNT,,00034,,,,Muss, + 60,Nachrichten-Endesegment,,UNT,0074,00034,,,Anzahl der Segmente in einerNachricht,X, + 61,Nachrichten-Endesegment,,UNT,0062,00034,,,Nachrichten-Referenznummer,X, + + ''' +# --- +# name: TestCli.test_kohlrahbi_cli_with_valid_arguments[19302] + ''' + ,Segmentname,Segmentgruppe,Segment,Datenelement,Segment ID,Code,Qualifier,Beschreibung,Bedingungsausdruck,Bedingung + 0,Nachrichten-Kopfsegment,,UNH,,00001,,,,Muss, + 1,Nachrichten-Kopfsegment,,UNH,0062,00001,,,Nachrichten-Referenznummer,X, + 2,Nachrichten-Kopfsegment,,UNH,0065,00001,ORDRSP,,Bestellantwort,X, + 3,Nachrichten-Kopfsegment,,UNH,0052,00001,D,,Entwurfs-Version,X, + 4,Nachrichten-Kopfsegment,,UNH,0054,00001,10A,,Ausgabe 2010 - A,X, + 5,Nachrichten-Kopfsegment,,UNH,0051,00001,UN,,UN/CEFACT,X, + 6,Nachrichten-Kopfsegment,,UNH,0057,00001,1.3,,Versionsnummer derzugrundeliegendenBDEW-Nachrichtenbeschreibung,X, + 7,Beginn der Nachricht,,BGM,,00002,,,,Muss, + 8,Beginn der Nachricht,,BGM,1001,00002,7,,Prozessdatenbericht,X, + 9,Beginn der Nachricht,,BGM,1001,,Z14,,Stammdaten der Markt-oder Messlokation,X, + 10,Beginn der Nachricht,,BGM,1004,00002,,,Dokumentennummer,X, + 11,Nachrichtendatum,,DTM,,00003,,,,Muss, + 12,Nachrichtendatum,,DTM,2005,00003,137,,Dokumenten-/Nachrichtendatum/-zeit,X, + 13,Nachrichtendatum,,DTM,2380,00003,,,"Datum oder Uhrzeit oderZeitspanne, Wert",X [931] [494],"[494] Das hier genannte Datum muss der Zeitpunkt sein, zu dem das Dokument erstellt wurde, oder ein Zeitpunkt, der davor liegt. + [931] Format: ZZZ = +00" + 14,Nachrichtendatum,,DTM,2379,00003,303,,CCYYMMDDHHMMZZZ,X, + 15,Abonnement,,IMD,,00007,,,,Muss, + 16,Abonnement,,IMD,7081,00007,Z01,,Start Abo,, + 17,Abonnement,,IMD,7081,,Z02,,Ende Abo,X, + 18,Produkt-/ Leistungsbeschreibung,,IMD,,00008,,,,Muss [1],[1] Wenn BGM+7 vorhanden + 19,Produkt-/ Leistungsbeschreibung,,IMD,7081,00008,Z11,,Lastgangdaten,X, + 20,Produkt-/ Leistungsbeschreibung,,IMD,7081,,Z12,,Zählerstände,X, + 21,Referenz Nachrichtennummer,SG1,,,,,,,Muss, + 22,Referenz Nachrichtennummer,SG1,RFF,,00009,,,,Muss, + 23,Referenz Nachrichtennummer,SG1,RFF,1153,00009,ON,,Auftragsnummer(Einkauf),X, + 24,Referenz Nachrichtennummer,SG1,RFF,1154,00009,,,Referenz Nachrichtennummer,X, + 25,Prüfidentifikator,SG1,,,,,,,Muss, + 26,Prüfidentifikator,SG1,RFF,,00012,,,,Muss, + 27,Prüfidentifikator,SG1,RFF,1153,00012,Z13,,Prüfidentifikator,X, + 28,Prüfidentifikator,SG1,RFF,1154,00012,19301,,Ablehnung Abo,, + 29,Prüfidentifikator,SG1,RFF,1154,,19302,,Bestätigung Ende Abo,X, + 30,Einzelheiten zu einer Anpassung/Änderung,SG2,,,,,,,Muss, + 31,Einzelheiten zu einer Anpassung/Änderung,SG2,AJT,,00013,,,,Muss, + 32,Einzelheiten zu einer Anpassung/Änderung,SG2,AJT,4465,00013,,,Code des Prüfschritts,X, + 33,Einzelheiten zu einer Anpassung/Änderung,SG2,AJT,1082,00013,Codeliste Strom Nr.S_0092Codeliste Strom Nr.S_0093,,S_0092S_0093,X, + 34,MP-ID Absender,SG3,,,,,,,Muss, + 35,MP-ID Absender,SG3,NAD,,00015,,,,Muss, + 36,MP-ID Absender,SG3,NAD,3035,00015,MS,,Dokumenten-/Nachrichtenausstellerbzw. -absender,X, + 37,MP-ID Absender,SG3,NAD,3039,00015,,,MP-ID,X [30],[30] MP-ID nur aus Sparte Strom + 38,MP-ID Absender,SG3,NAD,3055,00015,9,,GS1,X, + 39,MP-ID Absender,SG3,NAD,3055,,293,,"DE, BDEW(Bundesverband derEnergie- undWasserwirtschaft e.V.)",X, + 40,Ansprechpartner,SG6,,,,,,,Muss, + 41,Ansprechpartner,SG6,CTA,,00016,,,,Muss, + 42,Ansprechpartner,SG6,CTA,3139,00016,IC,,Informationskontakt,X, + 43,Ansprechpartner,SG6,CTA,3412,00016,,,Kontakt,X, + 44,Kommunikationsverbindung,SG6,COM,,00017,,,,Muss, + 45,Kommunikationsverbindung,SG6,COM,3148,00017,,,"Kommunikationsadresse,Identifikation",X, + 46,Kommunikationsverbindung,SG6,COM,3155,00017,EM,,Elektronische Post,X [1P0..1], + 47,Kommunikationsverbindung,SG6,COM,3155,,FX,,Telefax,X [1P0..1], + 48,Kommunikationsverbindung,SG6,COM,3155,,TE,,Telefon,X [1P0..1], + 49,Kommunikationsverbindung,SG6,COM,3155,,AJ,,weiteres Telefon,X [1P0..1], + 50,Kommunikationsverbindung,SG6,COM,3155,,AL,,Handy,X [1P0..1], + 51,MP-ID Empfänger,SG3,,,,,,,Muss, + 52,MP-ID Empfänger,SG3,NAD,,00018,,,,Muss, + 53,MP-ID Empfänger,SG3,NAD,3035,00018,MR,,Nachrichtenempfänger,X, + 54,MP-ID Empfänger,SG3,NAD,3039,00018,,,MP-ID,X [30],[30] MP-ID nur aus Sparte + 55,MP-ID Empfänger,SG3,NAD,3055,00018,9,,GS1,X, + 56,MP-ID Empfänger,SG3,NAD,3055,,293,,"DE, BDEW(Bundesverband derEnergie- undWasserwirtschaft e.V.)",X, + 57,Abschnitts-Kontrollsegment,,UNS,,00030,,,,Muss, + 58,Abschnitts-Kontrollsegment,,UNS,0081,00030,S,,Trennung von Positions-und Summenteil,X, + 59,Nachrichten-Endesegment,,UNT,,00034,,,,Muss, + 60,Nachrichten-Endesegment,,UNT,0074,00034,,,Anzahl der Segmente in einerNachricht,X, + 61,Nachrichten-Endesegment,,UNT,0062,00034,,,Nachrichten-Referenznummer,X, + + ''' +# --- +# name: TestCli.test_kohlrahbi_cli_with_valid_arguments[21002] + ''' + ,Segmentname,Segmentgruppe,Segment,Datenelement,Segment ID,Code,Qualifier,Beschreibung,Bedingungsausdruck,Bedingung + 0,Nachrichten-Kopfsegment,,UNH,,00001,,,,Muss, + 1,Nachrichten-Kopfsegment,,UNH,0062,00001,,,Nachrichten-Referenznummer,X, + 2,Nachrichten-Kopfsegment,,UNH,0065,00001,IFTSTA,,Multimodaler Statusbericht,X, + 3,Nachrichten-Kopfsegment,,UNH,0052,00001,D,,Entwurfs-Version,X, + 4,Nachrichten-Kopfsegment,,UNH,0054,00001,18A,,Ausgabe 2018 - A,X, + 5,Nachrichten-Kopfsegment,,UNH,0051,00001,UN,,UN/CEFACT,X, + 6,Nachrichten-Kopfsegment,,UNH,0057,00001,2.0e,,Versionsnummer derzugrundeliegendenBDEW-Nachrichtenbeschreibung,X, + 7,Beginn der Nachricht,,BGM,,00002,,,,Muss, + 8,Beginn der Nachricht,,BGM,1001,00002,Z03,,MaBiS Meldung(en),X, + 9,Beginn der Nachricht,,BGM,1004,00002,,,Dokumentennummer,X, + 10,Dokumentendatum,,DTM,,00003,,,,Muss, + 11,Dokumentendatum,,DTM,2005,00003,137,,Dokumenten-/Nachrichtendatum/-zeit,X, + 12,Dokumentendatum,,DTM,2380,00003,,,"Datum oder Uhrzeit oderZeitspanne, Wert",X [931] [494],"[494] Das hier genannte Datum muss der Zeitpunkt sein, zu dem das Dokument erstellt wurde, oder ein Zeitpunkt, der davor liegt + [931] Format: ZZZ = +00" + 13,Dokumentendatum,,DTM,2379,00003,303,,CCYYMMDDHHMMZZZ,X, + 14,MP-ID Empfänger,SG1,,,,,,,Muss, + 15,MP-ID Empfänger,SG1,NAD,,00004,,,,Muss, + 16,MP-ID Empfänger,SG1,NAD,3035,00004,,,,MR, + 17,MP-ID Empfänger,SG1,NAD,3039,00004,,,MP-ID,X [27],[27] Nur MP-ID aus Sparte Strom + 18,MP-ID Empfänger,SG1,NAD,3055,00004,9,,GS1,X, + 19,MP-ID Empfänger,SG1,NAD,3055,,293,,"DE, BDEW (Bundesverbandder Energie- undWasserwirtschaft e.V.)",X, + 20,MP-ID Absender,SG1,,,,,,,Muss, + 21,MP-ID Absender,SG1,NAD,,00005,,,,Muss, + 22,MP-ID Absender,SG1,NAD,3035,00005,Nachrichtenaussteller bzw.-absender,,,MS, + 23,MP-ID Absender,SG1,NAD,3039,00005,,,MP-ID,X [27],[27] Nur MP-ID aus Sparte Strom + 24,MP-ID Absender,SG1,NAD,3055,00005,9,,GS1,X, + 25,MP-ID Absender,SG1,NAD,3055,,293,,"DE, BDEW (Bundesverbandder Energie- undWasserwirtschaft e.V.)",X, + 26,Ansprechpartner,SG2,,,,,,,Kann, + 27,Ansprechpartner,SG2,CTA,,00006,,,,Muss, + 28,Ansprechpartner,SG2,CTA,3139,00006,,,,IC, + 29,Ansprechpartner,SG2,CTA,3412,00006,,,Kontakt,X, + 30,Kommunikationsverbindung,SG2,COM,,00007,,,,Muss, + 31,Kommunikationsverbindung,SG2,COM,3148,00007,,,Nummer / E-Mail Adresse,X, + 32,Kommunikationsverbindung,SG2,COM,3155,00007,EM,,E-Mail,X [1P0..1], + 33,Kommunikationsverbindung,SG2,COM,3155,,FX,,Telefax,X [1P0..1], + 34,Kommunikationsverbindung,SG2,COM,3155,,TE,,Telefon,X [1P0..1], + 35,Kommunikationsverbindung,SG2,COM,3155,,AJ,,weiteres Telefon,X [1P0..1], + 36,Kommunikationsverbindung,SG2,COM,3155,,AL,,Handy,X [1P0..1], + 37,Einzelheiten zu Equipment,SG4,,,,,,,Muss, + 38,Einzelheiten zu Equipment,SG4,EQD,,00008,,,,Muss, + 39,Einzelheiten zu Equipment,SG4,EQD,8053,00008,,,,Z01, + 40,Einzelheiten zu Equipment,SG4,EQD,8260,00008,,,Vorgangsnummer,X [911],"[911] Format: Mögliche Werte: 1 bis n, je Nachricht bei 1 beginnend und fortlaufend aufsteigend" + 41,Prüfidentifikator,SG4,RFF,,00009,,,,Muss, + 42,Prüfidentifikator,SG4,RFF,1153,00009,Z13,,Prüfidentifikator,X, + 43,Prüfidentifikator,SG4,RFF,1154,00009,21002,,MaBiS / Abweisung vomBIKO an NB/ÜNB,X, + 44,Versionsangabe der betrachteten Summenzeitreihe,SG4,RFF,,00010,,,,Muss, + 45,Versionsangabe der betrachteten Summenzeitreihe,SG4,RFF,1153,00010,AUU,,Referenz auf eine Zeitreihe,X, + 46,Versionsangabe der betrachteten Summenzeitreihe,SG4,RFF,1154,00010,,,Version der Summenzeitreihe,X, + 47,Meldepunkt,SG6,,,,,,,Muss, + 48,Meldepunkt,SG6,LOC,,00011,,,,Muss, + 49,Meldepunkt,SG6,LOC,3227,00011,,,,172, + 50,Meldepunkt,SG6,LOC,3225,00011,,,Identifikator,X [951] [504],"[504] Hinweis: Verwendung der ID des MaBiS-ZP + [951] Format: Zählpunktbezeichnung" + 51,Betrachtungszeitintervall,SG6,DTM,,00012,,,,Muss, + 52,Betrachtungszeitintervall,SG6,DTM,2005,00012,492,,"Bilanzierungsdatum, -zeit,-periode",X, + 53,Betrachtungszeitintervall,SG6,DTM,2380,00012,,,"Datum oder Uhrzeit oderZeitspanne, Wert",X, + 54,Betrachtungszeitintervall,SG6,DTM,2379,00012,610,,CCYYMM,X, + 55,Zeitpunkt der Statusvergabe,SG6,DTM,,00013,,,,Muss, + 56,Zeitpunkt der Statusvergabe,SG6,DTM,2005,00013,334,,"Statusveränderung,Datum/Zeit",X, + 57,Zeitpunkt der Statusvergabe,SG6,DTM,2380,00013,,,"Datum oder Uhrzeit oderZeitspanne, Wert",X [931] [495],"[495] Der Zeitpunkt muss ≤ dem Wert im DE2380 des DTM+137 sein + [931] Format: ZZZ = +00" + 58,Zeitpunkt der Statusvergabe,SG6,DTM,2379,00013,304,,CCYYMMDDHHMMSSZZZ,X, + 59,Abweisung der Summenzeitreihe,SG7,,,,,,,Muss, + 60,Abweisung der Summenzeitreihe,SG7,STS,,00015,,,,Muss, + 61,Abweisung der Summenzeitreihe,SG7,STS,9015,00015,Z02,,Abweisung derSummenzeitreihe,X, + 62,Abweisung der Summenzeitreihe,SG7,STS,9013,00015,,,Code des Prüfschritts,X, + 63,Abweisung der Summenzeitreihe,SG7,STS,1131,00015,E_0008,,EBD Nr. E_0008,X, + 64,Abweisung der Summenzeitreihe,SG7,STS,1131,,E_0023,,EBD Nr. E_0023,X, + 65,Abweisung der Summenzeitreihe,SG7,STS,1131,,E_0029,,EBD Nr. E_0029,X, + 66,Abweisung der Summenzeitreihe,SG7,STS,1131,,E_0036,,EBD Nr. E_0036,X, + 67,Abweisung der Summenzeitreihe,SG7,STS,1131,,E_0038,,EBD Nr. E_0038,X, + 68,Abweisung der Summenzeitreihe,SG7,STS,1131,,E_0073,,EBD Nr. E_0073,X, + 69,Abweisung der Summenzeitreihe,SG7,STS,1131,,E_0080,,EBD Nr. E_0080,X, + 70,Nachrichten-Endesegment,,UNT,,00126,,,,Muss, + 71,Nachrichten-Endesegment,,UNT,0074,00126,,,Anzahl der Segmente in einerNachricht,X, + 72,Nachrichten-Endesegment,,UNT,0062,00126,,,Nachrichten-Referenznummer,X, + + ''' +# --- +# name: TestCli.test_kohlrahbi_cli_with_valid_arguments[21010] + ''' + ,Segmentname,Segmentgruppe,Segment,Datenelement,Segment ID,Code,Qualifier,Beschreibung,Bedingungsausdruck,Bedingung + 0,Nachrichten-Kopfsegment,,UNH,,00001,,,,Muss, + 1,Nachrichten-Kopfsegment,,UNH,0062,00001,,,Nachrichten-Referenznummer,X, + 2,Nachrichten-Kopfsegment,,UNH,0065,00001,IFTSTA,,MultimodalerStatusbericht,X, + 3,Nachrichten-Kopfsegment,,UNH,0052,00001,D,,Entwurfs-Version,X, + 4,Nachrichten-Kopfsegment,,UNH,0054,00001,18A,,Ausgabe 2018 - A,X, + 5,Nachrichten-Kopfsegment,,UNH,0051,00001,UN,,UN/CEFACT,X, + 6,Nachrichten-Kopfsegment,,UNH,0057,00001,2.0e,,VersionsnummerderzugrundeliegendenBDEW-Nachrichtenbeschreibung,X, + 7,Beginn der Nachricht,,BGM,,00002,,,,Muss, + 8,Beginn der Nachricht,,BGM,1001,00002,Z09,,WiM Meldung(en),X, + 9,Beginn der Nachricht,,BGM,1004,00002,,,Dokumentennummer,X, + 10,Dokumentendatum,,DTM,,00003,,,,Muss, + 11,Dokumentendatum,,DTM,2005,00003,137,,Dokumenten-/Nachrichtendatum/-zeit,X, + 12,Dokumentendatum,,DTM,2380,00003,,,"Datum oder Uhrzeit oderZeitspanne, Wert",X [931][494],"[494] Das hier genannte Datum muss der Zeitpunkt sein, zu dem das Dokument erstellt wurde, oder ein Zeitpunkt, der davor liegt + [931] Format: ZZZ = +00" + 13,Dokumentendatum,,DTM,2379,00003,303,,CCYYMMDDHHMMZZZ,X, + 14,MP-ID Empfänger,SG1,,,,,,,Muss, + 15,MP-ID Empfänger,SG1,NAD,,00004,,,,Muss, + 16,MP-ID Empfänger,SG1,NAD,3035,00004,MR,,Nachrichtenempfänger,X, + 17,MP-ID Empfänger,SG1,NAD,3039,00004,,,MP-ID,X, + 18,MP-ID Empfänger,SG1,NAD,3055,00004,9,,GS1,X, + 19,MP-ID Empfänger,SG1,NAD,3055,,293,,"DE, BDEW(Bundesverbandder Energie- undWasserwirtschafte.V.)",X, + 20,MP-ID Empfänger,SG1,NAD,3055,,332,,"DE, DVGW Service& Consult GmbH",X, + 21,MP-ID Absender,SG1,,,,,,,Muss, + 22,MP-ID Absender,SG1,NAD,,00005,,,,Muss, + 23,MP-ID Absender,SG1,NAD,3035,00005,MS,,Dokumenten-/Nachrichtenaussteller bzw. -absender,X, + 24,MP-ID Absender,SG1,NAD,3039,00005,,,MP-ID,X, + 25,MP-ID Absender,SG1,NAD,3055,00005,9,,GS1,X, + 26,MP-ID Absender,SG1,NAD,3055,,293,,"DE, BDEW(Bundesverbandder Energie- undWasserwirtschafte.V.)",X, + 27,MP-ID Absender,SG1,NAD,3055,,332,,"DE, DVGW Service& Consult GmbH",X, + 28,Ansprechpartner,SG2,,,,,,,Kann, + 29,Ansprechpartner,SG2,CTA,,00006,,,,Muss, + 30,Ansprechpartner,SG2,CTA,3139,00006,IC,,Informationskontakt,X, + 31,Ansprechpartner,SG2,CTA,3412,00006,,,Kontakt,X, + 32,Kommunikationsverbindu ng,SG2,COM,,00007,,,,Muss, + 33,Kommunikationsverbindu ng,SG2,COM,3148,00007,,,Nummer / E-Mail Adresse,X, + 34,Kommunikationsverbindu ng,SG2,COM,3155,00007,EM,,E-Mail,X [1P0..1], + 35,Kommunikationsverbindu ng,SG2,COM,3155,,FX,,Telefax,X [1P0..1], + 36,Kommunikationsverbindu ng,SG2,COM,3155,,TE,,Telefon,X [1P0..1], + 37,Kommunikationsverbindu ng,SG2,COM,3155,,AJ,,weiteres Telefon,X [1P0..1], + 38,Kommunikationsverbindu ng,SG2,COM,3155,,AL,,Handy,X [1P0..1], + 39,Sendungsdaten,SG14,,,,,,,Muss, + 40,Sendungsdaten,SG14,CNI,,00019,,,,Muss, + 41,Sendungsdaten,SG14,CNI,1490,00019,,,Vorgangsnummer,X [911],"[911] Format: Mögliche Werte: 1 bis n, je Nachricht bei 1 beginnend und fortlaufend aufsteigend" + 42,Meldepunkt,SG14,LOC,,00020,,,,Muss, + 43,Meldepunkt,SG14,LOC,3227,00020,172,,Meldepunkt,X, + 44,Meldepunkt,SG14,LOC,3225,00020,,,Identifikator,X [951][505],"[505] Hinweis: Verwendung der ID der Messlokation + [951] Format: Zählpunktbezeichnu ng" + 45,MSB-Wechselstatus,SG15,,,,,,,Muss, + 46,MSB-Wechselstatus,SG15,STS,,00021,,,,Muss, + 47,MSB-Wechselstatus,SG15,STS,9015,00021,Z10,,MSB-Wechsel nachMsbG,X, + 48,MSB-Wechselstatus,SG15,STS,4405,00021,Z13,,gescheitert,, + 49,MSB-Wechselstatus,SG15,STS,4405,,Z14,,erfolgreich,X, + 50,MSB-Wechselstatus,SG15,STS,9013,00021,,,Code des Prüfschritts,, + 51,MSB-Wechselstatus,SG15,STS,9013,,E17,,Ablehnung wg.Fristüberschreitung,, + 52,MSB-Wechselstatus,SG15,STS,1131,00021,G_005,,Codeliste Gas Nr.,, + 53,MSB-Wechselstatus,SG15,STS,1131,,5S_0057,,G_0055Codeliste StromNr. S_0057,,"[492] wenn MP-ID in NAD+MR aus Sparte Strom + [493] wenn MP-ID in NAD+MR aus Sparte Gas" + 54,Prüfidentifikator,SG15,RFF,,00022,,,,Muss, + 55,Prüfidentifikator,SG15,RFF,1153,00022,Z13,,Prüfidentifikator,X, + 56,Prüfidentifikator,SG15,RFF,1154,00022,21009,,WiM /Statusmeldung(gescheitert) vomMSBN an NB,, + 57,Prüfidentifikator,SG15,RFF,1154,,21010,,WiM /Statusmeldung(erfolgreich) vomMSBN an NB,X, + 58,Prüfidentifikator,SG15,RFF,1154,,21011,,WiM /Statusmeldung(MSB/Scheitermeldung)vom NB an MSBN /MSBA / LF,, + 59,Prüfidentifikator,SG15,RFF,1154,,21012,,WiM /Statusmeldung(erfolgreich) vomNB an MSBN,, + 60,Prüfidentifikator,SG15,RFF,1154,,21013,,WiM /Statusmeldung(gescheitert) vomNB an MSBN /MSBA / LF,, + 61,Referenz Nachrichtennummer,SG15,RFF,,00023,,,,, + 62,Referenz Nachrichtennummer,SG15,RFF,1153,00023,ACW,,Referenznummereinervorangegangenen,, + 63,Referenz Nachrichtennummer,SG15,RFF,1154,00023,,,"Referenz, Identifikation",, + 64,Referenz Vorgangsnummer,SG15,RFF,,00024,,,,, + 65,Referenz Vorgangsnummer,SG15,RFF,1153,00024,ADY,,Mitteilungsnummer,, + 66,Referenz Vorgangsnummer,SG15,RFF,1154,00024,,,"Referenz, Identifikation",, + 67,Datum/Uhrzeit/ Zeitspanne,SG15,DTM,,00026,,,,Muss, + 68,Datum/Uhrzeit/ Zeitspanne,SG15,DTM,2005,00026,293,,Fertigstellungsdatum/-zeit,X, + 69,Datum/Uhrzeit/ Zeitspanne,SG15,DTM,2380,00026,,,"Datum oder Uhrzeit oderZeitspanne, Wert",X ([UB3][26] ∧([521] ⊻[522])) ⊻([931][117]),"[26] Wenn MP-ID in SG1 NAD+MR in der Rolle NB + [117] Wenn MP-ID in SG1 NAD+MR in der Rolle MSB + [521] Hinweis: Zeitpunkt, ab dem der MSBN tatsächlich den Messstellenbetrieb übernimmt + [522] Hinweis: Zeitpunkt, ab dem der gMSB den Messstellenbetrieb übernimmt + [931] Format: ZZZ = +00" + 70,Datum/Uhrzeit/ Zeitspanne,SG15,DTM,2379,00026,303,,CCYYMMDDHHMMZZZ,X, + 71,Nachrichten- Endesegment,,UNT,,00126,,,,Muss, + 72,Nachrichten- Endesegment,,UNT,0074,00126,,,Anzahl der Segmente ineiner Nachricht,X, + 73,Nachrichten- Endesegment,,UNT,0062,00126,,,Nachrichten-Referenznummer,X, + + ''' +# --- +# name: TestCli.test_kohlrahbi_cli_with_valid_arguments[21015] + ''' + ,Segmentname,Segmentgruppe,Segment,Datenelement,Segment ID,Code,Qualifier,Beschreibung,Bedingungsausdruck,Bedingung + 0,Nachrichten-Kopfsegment,,UNH,,00001,,,,Muss, + 1,Nachrichten-Kopfsegment,,UNH,0062,00001,,,Nachrichten-Referenznummer,X, + 2,Nachrichten-Kopfsegment,,UNH,0065,00001,IFTSTA,,Multimodaler Statusbericht,X, + 3,Nachrichten-Kopfsegment,,UNH,0052,00001,D,,Entwurfs-Version,X, + 4,Nachrichten-Kopfsegment,,UNH,0054,00001,18A,,Ausgabe 2018 - A,X, + 5,Nachrichten-Kopfsegment,,UNH,0051,00001,UN,,UN/CEFACT,X, + 6,Nachrichten-Kopfsegment,,UNH,0057,00001,2.0e,,Versionsnummer derzugrundeliegendenBDEW-Nachrichtenbeschreibung,X, + 7,Beginn der Nachricht,,BGM,,00002,,,,Muss, + 8,Beginn der Nachricht,,BGM,1001,00002,Z09,,WiM Meldung(en),X, + 9,Beginn der Nachricht,,BGM,1004,00002,,,Dokumentennummer,X, + 10,Dokumentendatum,,DTM,,00003,,,,Muss, + 11,Dokumentendatum,,DTM,2005,00003,137,,Dokumenten-/Nachrichtendatum/-zeit,X, + 12,Dokumentendatum,,DTM,2380,00003,,,"Datum oder Uhrzeit oderZeitspanne, Wert",X [931] [494],"[494] Das hier genannte Datum muss der Zeitpunkt sein, zu dem das Dokument erstellt wurde, oder ein Zeitpunkt, der davor liegt + [931] Format: ZZZ = +00" + 13,Dokumentendatum,,DTM,2379,00003,303,,CCYYMMDDHHMMZZZ,X, + 14,MP-ID Empfänger,SG1,,,,,,,Muss, + 15,MP-ID Empfänger,SG1,NAD,,00004,,,,Muss, + 16,MP-ID Empfänger,SG1,NAD,3035,00004,,,,MR, + 17,MP-ID Empfänger,SG1,NAD,3039,00004,,,MP-ID,X [28],[28] Nur MP-ID aus Sparte Gas + 18,MP-ID Empfänger,SG1,NAD,3055,00004,9,,GS1,X, + 19,MP-ID Empfänger,SG1,NAD,3055,,332,,"DE, DVGW Service &Consult GmbH",X, + 20,MP-ID Absender,SG1,,,,,,,Muss, + 21,MP-ID Absender,SG1,NAD,,00005,,,,Muss, + 22,MP-ID Absender,SG1,NAD,3035,00005,Nachrichtenaussteller bzw.-absender,,,MS, + 23,MP-ID Absender,SG1,NAD,3039,00005,,,MP-ID,X [28],[28] Nur MP-ID aus Sparte Gas + 24,MP-ID Absender,SG1,NAD,3055,00005,9,,GS1,X, + 25,MP-ID Absender,SG1,NAD,3055,,332,,"DE, DVGW Service &Consult GmbH",X, + 26,Ansprechpartner,SG2,,,,,,,Kann, + 27,Ansprechpartner,SG2,CTA,,00006,,,,Muss, + 28,Ansprechpartner,SG2,CTA,3139,00006,,,,IC, + 29,Ansprechpartner,SG2,CTA,3412,00006,,,Kontakt,X, + 30,Kommunikationsverbindung,SG2,COM,,00007,,,,Muss, + 31,Kommunikationsverbindung,SG2,COM,3148,00007,,,Nummer / E-Mail Adresse,X, + 32,Kommunikationsverbindung,SG2,COM,3155,00007,EM,,E-Mail,X [1P0..1], + 33,Sendungsdaten,SG14,,,,,,,Muss, + 34,Sendungsdaten,SG14,CNI,,00019,,,,Muss, + 35,Sendungsdaten,SG14,CNI,1490,00019,,,Vorgangsnummer,X [911],"[911] Format: Mögliche Werte: 1 bis n, je Nachricht bei 1 beginnend und fortlaufend aufsteigend" + 36,Meldepunkt,SG14,LOC,,00020,,,,Muss, + 37,Meldepunkt,SG14,LOC,3227,00020,,,,172, + 38,Meldepunkt,SG14,LOC,3225,00020,,,Identifikator,X [951] [505],"[505] Hinweis: Verwendung der ID der Messlokation + [951] Format: Zählpunktbezeichnung" + 39,MSB-Wechselstatus,SG15,,,,,,,Muss, + 40,MSB-Wechselstatus,SG15,STS,,00021,,,,Muss, + 41,MSB-Wechselstatus,SG15,STS,9015,00021,Z10,,MSB-Wechsel nach MsbG,X, + 42,MSB-Wechselstatus,SG15,STS,4405,00021,Z14,,erfolgreich,X, + 43,Prüfidentifikator,SG15,RFF,,00022,,,,Muss, + 44,Prüfidentifikator,SG15,RFF,1153,00022,Z13,,Prüfidentifikator,X, + 45,Prüfidentifikator,SG15,RFF,1154,00022,21015,,WiM /Informationsmeldung(erfolgreich) vom NB anMSBA,X, + 46,Datum/Uhrzeit/Zeitspanne,SG15,DTM,,00026,,,,Muss, + 47,Datum/Uhrzeit/Zeitspanne,SG15,DTM,2005,00026,293,,Fertigstellungsdatum/-zeit,X, + 48,Datum/Uhrzeit/Zeitspanne,SG15,DTM,2380,00026,,,"Datum oder Uhrzeit oderZeitspanne, Wert",X [UB2], + 49,Datum/Uhrzeit/Zeitspanne,SG15,DTM,2379,00026,303,,CCYYMMDDHHMMZZZ,X, + 50,Messstellenbetreiber an der Messlokation,SG17,,,,,,,Muss, + 51,Messstellenbetreiber an der Messlokation,SG17,NAD,,00027,,,,Muss, + 52,Messstellenbetreiber an der Messlokation,SG17,NAD,3035,00027,,,,DEB, + 53,Messstellenbetreiber an der Messlokation,SG17,NAD,3039,00027,,,MP-ID,X, + 54,Messstellenbetreiber an der Messlokation,SG17,NAD,3055,00027,9,,GS1,X, + 55,Messstellenbetreiber an der Messlokation,SG17,NAD,3055,,332,,"DE, DVGW Service &Consult GmbH",X, + 56,Nachrichten-Endesegment,,UNT,,00126,,,,Muss, + 57,Nachrichten-Endesegment,,UNT,0074,00126,,,Anzahl der Segmente in einerNachricht,X, + 58,Nachrichten-Endesegment,,UNT,0062,00126,,,Nachrichten-Referenznummer,X, + + ''' +# --- +# name: TestCli.test_kohlrahbi_cli_with_valid_arguments[21030] + ''' + ,Segmentname,Segmentgruppe,Segment,Datenelement,Segment ID,Code,Qualifier,Beschreibung,Bedingungsausdruck,Bedingung + 0,Nachrichten-Kopfsegment,,UNH,,00001,,,,Muss, + 1,Nachrichten-Kopfsegment,,UNH,0062,00001,,,Nachrichten-Referenznummer,X, + 2,Nachrichten-Kopfsegment,,UNH,0065,00001,IFTSTA,,MultimodalerStatusbericht,X, + 3,Nachrichten-Kopfsegment,,UNH,0052,00001,D,,Entwurfs-Version,X, + 4,Nachrichten-Kopfsegment,,UNH,0054,00001,18A,,Ausgabe 2018 - A,X, + 5,Nachrichten-Kopfsegment,,UNH,0051,00001,UN,,UN/CEFACT,X, + 6,Nachrichten-Kopfsegment,,UNH,0057,00001,2.0e,,Versionsnummer derzugrundeliegendenBDEW-Nachrichtenbeschreibung,X, + 7,Beginn der Nachricht,,BGM,,00002,,,,Muss, + 8,Beginn der Nachricht,,BGM,1001,00002,Z09,,WiM Meldung(en),X, + 9,Beginn der Nachricht,,BGM,1004,00002,,,Dokumentennummer,X, + 10,Dokumentendatum,,DTM,,00003,,,,Muss, + 11,Dokumentendatum,,DTM,2005,00003,137,,Dokumenten-/Nachrichtendatum/-zeit,X, + 12,Dokumentendatum,,DTM,2380,00003,,,"Datum oder Uhrzeit oderZeitspanne, Wert",X [931][494],"[494] Das hier genannte Datum muss der Zeitpunkt sein, zu dem das Dokument erstellt wurde, oder ein Zeitpunkt, der davor liegt + [931] Format: ZZZ = +00" + 13,Dokumentendatum,,DTM,2379,00003,303,,CCYYMMDDHHMMZZZ,X, + 14,MP-ID Empfänger,SG1,,,,,,,Muss, + 15,MP-ID Empfänger,SG1,NAD,,00004,,,,Muss, + 16,MP-ID Empfänger,SG1,NAD,3035,00004,MR,,Nachrichtenempfänger,X, + 17,MP-ID Empfänger,SG1,NAD,3039,00004,,,MP-ID,X [27],[27] Nur MP-ID aus Sparte Strom + 18,MP-ID Empfänger,SG1,NAD,3055,00004,9,,GS1,X, + 19,MP-ID Empfänger,SG1,NAD,3055,,293,,"DE, BDEW(Bundesverband derEnergie- undWasserwirtschaft e.V.)",X, + 20,MP-ID Absender,SG1,,,,,,,Muss, + 21,MP-ID Absender,SG1,NAD,,00005,,,,Muss, + 22,MP-ID Absender,SG1,NAD,3035,00005,MS,,Dokumenten-/Nachrichtenausstellerbzw. -absender,X, + 23,MP-ID Absender,SG1,NAD,3039,00005,,,MP-ID,X [27],[27] Nur MP-ID aus Sparte Strom + 24,MP-ID Absender,SG1,NAD,3055,00005,9,,GS1,X, + 25,MP-ID Absender,SG1,NAD,3055,,293,,"DE, BDEW",X, + 26,Ansprechpartner,SG2,,,,,,,Kann, + 27,Ansprechpartner,SG2,CTA,,00006,,,,Muss, + 28,Ansprechpartner,SG2,CTA,3139,00006,IC,,Informationskontakt,X, + 29,Ansprechpartner,SG2,CTA,3412,00006,,,Kontakt,X, + 30,Kommunikationsverbindung,SG2,COM,,00007,,,,Muss, + 31,Kommunikationsverbindung,SG2,COM,3148,00007,,,Nummer / E-Mail Adresse,X, + 32,Kommunikationsverbindung,SG2,COM,3155,00007,EM,,E-Mail,X [1P0..1], + 33,Kommunikationsverbindung,SG2,COM,3155,,FX,,Telefax,X [1P0..1], + 34,Kommunikationsverbindung,SG2,COM,3155,,TE,,Telefon,X [1P0..1], + 35,Kommunikationsverbindung,SG2,COM,3155,,AJ,,weiteres Telefon,X [1P0..1], + 36,Kommunikationsverbindung,SG2,COM,3155,,AL,,Handy,X [1P0..1], + 37,Sendungsdaten,SG14,,,,,,,Muss, + 38,Sendungsdaten,SG14,CNI,,00019,,,,Muss, + 39,Sendungsdaten,SG14,CNI,1490,00019,,,Vorgangsnummer,X [911],"[911] Format: Mögliche Werte: 1 bis n, je Nachricht bei 1 beginnend und fortlaufend aufsteigend" + 40,Meldepunkt,SG14,LOC,,00020,,,,Muss, + 41,Meldepunkt,SG14,LOC,3227,00020,172,,Meldepunkt,X, + 42,Meldepunkt,SG14,LOC,3225,00020,,,Identifikator,X [951][505],"[505] Hinweis: Verwendung der ID der Messlokation + [951] Format: Zählpunktbezeichnung" + 43,Ersteinbau iMS Planungsstatus,SG15,,,,,,,Muss,[19] Wenn SG15 STS+Z24 nicht vorhanden. + 44,Ersteinbau iMS Planungsstatus,SG15,STS,,00034,,,,Muss, + 45,Ersteinbau iMS Planungsstatus,SG15,STS,9015,00034,Z19,,Ersteinbau iMS,X, + 46,Ersteinbau iMS Planungsstatus,SG15,STS,4405,00034,Z17,,geplant,, + 47,Ersteinbau iMS Planungsstatus,SG15,STS,4405,,Z30,,zugestimmt,X [503], + 48,Ersteinbau iMS Planungsstatus,SG15,STS,4405,,Z31,,widersprochen,,[503] Hinweis: Auf Selbsteinbau eines iMS oder einer mME wird verzichtet + 49,Ersteinbau iMS Planungsstatus,SG15,STS,9013,00034,,,Code des Prüfschritts,X [48],"[47] Es sind nur Codes aus dem EBD-Cluster Ablehnung möglich. + [48] Es sind nur Codes aus dem EBD-Cluster Zustimmung möglich." + 50,Ersteinbau iMS Planungsstatus,SG15,STS,1131,00034,E_0233,,EBD Nr. E_0233,X, + 51,Prüfidentifikator,SG15,RFF,,00035,,,,Muss, + 52,Prüfidentifikator,SG15,RFF,1153,00035,Z13,,Prüfidentifikator,X, + 53,Prüfidentifikator,SG15,RFF,1154,00035,21029,,WiM / Vorabinformation,, + 54,Prüfidentifikator,SG15,RFF,1154,,21030,,WiM / ZustimmungiMS-Ersteinbau,X, + 55,Prüfidentifikator,SG15,RFF,1154,,21031,,WiM / Bestandsschutz /Eigenausbau iMS,, + 56,Referenz auf die Marktlokation,SG15,RFF,,00036,,,,,[20] Wenn MP-ID in SG1 NAD+MR in der Rolle LF + 57,Referenz auf die Marktlokation,SG15,RFF,1153,00036,AVE,,Meldepunkt,, + 58,Referenz auf die Marktlokation,SG15,RFF,1154,00036,,,ID einer Marktlokation,,"[506] Hinweis: Verwendung der ID der Marktlokation + [950] Format: Marktlokations-ID" + 59,Referenz auf den Preisschlüsselstamm,SG15,RFF,,00037,,,,,"[20] Wenn MP-ID in SG1 NAD+MR in der Rolle LF + [144] Wenn RFF+Z45 in dieser SG15 nicht vorhanden" + 60,Referenz auf den Preisschlüsselstamm,SG15,RFF,1153,00037,Z17,,Preisschlüsselstamm,, + 61,Referenz auf den Preisschlüsselstamm,SG15,RFF,1154,00037,,,Code des Preisschlüsselstamms,, + 62,Referenz auf die Artikel-ID,SG15,RFF,,00038,,,,,"[20] Wenn MP-ID in SG1 NAD+MR in der Rolle LF + [145] Wenn RFF+Z17 in dieser SG15 nicht vorhanden" + 63,Referenz auf die Artikel-ID,SG15,RFF,1153,00038,Z45,,Referenz auf die Artikel-ID,, + 64,Referenz auf die Artikel-ID,SG15,RFF,1154,00038,,,Artikel-ID,, + 65,Datum/Uhrzeit/Zeitspanne,SG15,DTM,,00039,,,,Muss, + 66,Datum/Uhrzeit/Zeitspanne,SG15,DTM,2005,00039,76,,"Lieferdatum/-zeit,geplant",X, + 67,Datum/Uhrzeit/Zeitspanne,SG15,DTM,2380,00039,,,"Datum oder Uhrzeit oderZeitspanne, Wert",X [496] ,[496] Der Zeitpunkt muss > dem Wert im DE2380 des DTM+137 sein + 68,Datum/Uhrzeit/Zeitspanne,SG15,DTM,2379,00039,102,,CCYYMMDD,X, + 69,Ersteinbau mME Planungsstatus,SG15,,,,,,,,"[18] Wenn SG15 STS+Z19 nicht vorhanden. + [20] Wenn MP-ID in SG1 NAD+MR in der Rolle LF" + 70,Ersteinbau mME Planungsstatus,SG15,STS,,00040,,,,, + 71,Ersteinbau mME Planungsstatus,SG15,STS,9015,00040,Z24,,Ersteinbau mME,, + 72,Ersteinbau mME Planungsstatus,SG15,STS,4405,00040,Z17,,geplant,, + 73,Prüfidentifikator,SG15,RFF,,00041,,,,, + 74,Prüfidentifikator,SG15,RFF,1153,00041,Z13,,Prüfidentifikator,, + 75,Prüfidentifikator,SG15,RFF,1154,00041,21029,,WiM / Vorabinformation,, + 76,Referenz auf die Marktlokation,SG15,RFF,,00042,,,,, + 77,Referenz auf die Marktlokation,SG15,RFF,1153,00042,AVE,,Meldepunkt,, + 78,Referenz auf die Marktlokation,SG15,RFF,1154,00042,,,ID einer Marktlokation,,"[506] Hinweis: Verwendung der ID der Marktlokation + [950] Format: Marktlokations-ID" + 79,Beginn des Zeitintervalls,SG15,DTM,,00043,,,,, + 80,Beginn des Zeitintervalls,SG15,DTM,2005,00043,469,,"Startdatum oder -zeitpunkt, frühestes/r",, + 81,Beginn des Zeitintervalls,SG15,DTM,2380,00043,,,"Datum oder Uhrzeit oderZeitspanne, Wert",,[496] Der Zeitpunkt muss > dem Wert im DE2380 des DTM+137 sein + 82,Beginn des Zeitintervalls,SG15,DTM,2379,00043,303,,CCYYMMDDHHMMZZZ,, + 83,Ende des Zeitintervalls,SG15,DTM,,00044,,,,, + 84,Ende des Zeitintervalls,SG15,DTM,2005,00044,472,,"Endedatum oder -zeitpunkt, spätestes/r",, + 85,Ende des Zeitintervalls,SG15,DTM,2380,00044,,,"Datum oder Uhrzeit oderZeitspanne, Wert",,[496] Der Zeitpunkt muss > dem Wert im DE2380 des DTM+137 sein + 86,Ende des Zeitintervalls,SG15,DTM,2379,00044,303,,CCYYMMDDHHMMZZZ,, + 87,Nachrichten-Endesegment,,UNT,,00126,,,,Muss, + 88,Nachrichten-Endesegment,,UNT,0074,00126,,,Anzahl der Segmente in einerNachricht,X, + 89,Nachrichten-Endesegment,,UNT,0062,00126,,,Nachrichten-Referenznummer,X, + + ''' +# --- +# name: TestCli.test_kohlrahbi_cli_with_valid_arguments[21039] + ''' + ,Segmentname,Segmentgruppe,Segment,Datenelement,Segment ID,Code,Qualifier,Beschreibung,Bedingungsausdruck,Bedingung + 0,Nachrichten-Kopfsegment,,UNH,,00001,,,,Muss, + 1,Nachrichten-Kopfsegment,,UNH,0062,00001,,,Nachrichten-Referenznummer,X, + 2,Nachrichten-Kopfsegment,,UNH,0065,00001,IFTSTA,,Multimodaler Statusbericht,X, + 3,Nachrichten-Kopfsegment,,UNH,0052,00001,D,,Entwurfs-Version,X, + 4,Nachrichten-Kopfsegment,,UNH,0054,00001,18A,,Ausgabe 2018 - A,X, + 5,Nachrichten-Kopfsegment,,UNH,0051,00001,UN,,UN/CEFACT,X, + 6,Nachrichten-Kopfsegment,,UNH,0057,00001,2.0e,,Versionsnummer derzugrundeliegendenBDEW-Nachrichtenbeschreibung,X, + 7,Beginn der Nachricht,,BGM,,00002,,,,Muss, + 8,Beginn der Nachricht,,BGM,1001,00002,Z33,,GPKE Meldung(en),X, + 9,Beginn der Nachricht,,BGM,1004,00002,,,Dokumentennummer,X, + 10,Dokumentendatum,,DTM,,00003,,,,Muss, + 11,Dokumentendatum,,DTM,2005,00003,137,,Dokumenten-/Nachrichtendatum/-zeit,X, + 12,Dokumentendatum,,DTM,2380,00003,,,"Datum oder Uhrzeit oderZeitspanne, Wert",X [931] [494],"[494] Das hier genannte Datum muss der Zeitpunkt sein, zu dem das Dokument erstellt wurde, oder ein Zeitpunkt, der davor liegt + [931] Format: ZZZ = +00" + 13,Dokumentendatum,,DTM,2379,00003,303,,CCYYMMDDHHMMZZZ,X, + 14,MP-ID Empfänger,SG1,,,,,,,Muss, + 15,MP-ID Empfänger,SG1,NAD,,00004,,,,Muss, + 16,MP-ID Empfänger,SG1,NAD,3035,00004,,,,MR, + 17,MP-ID Empfänger,SG1,NAD,3039,00004,,,MP-ID,X, + 18,MP-ID Empfänger,SG1,NAD,3055,00004,9,,GS1,X, + 19,MP-ID Empfänger,SG1,NAD,3055,,293,,"DE, BDEW (Bundesverbandder Energie- undWasserwirtschaft e.V.)",X, + 20,MP-ID Empfänger,SG1,NAD,3055,,332,,"DE, DVGW Service &Consult GmbH",X, + 21,MP-ID Absender,SG1,,,,,,,Muss, + 22,MP-ID Absender,SG1,NAD,,00005,,,,Muss, + 23,MP-ID Absender,SG1,NAD,3035,00005,Nachrichtenaussteller bzw.-absender,,,MS, + 24,MP-ID Absender,SG1,NAD,3039,00005,,,MP-ID,X, + 25,MP-ID Absender,SG1,NAD,3055,00005,9,,GS1,X, + 26,MP-ID Absender,SG1,NAD,3055,,293,,"DE, BDEW (Bundesverbandder Energie- undWasserwirtschaft e.V.)",X, + 27,MP-ID Absender,SG1,NAD,3055,,332,,"DE, DVGW Service &Consult GmbH",X, + 28,Ansprechpartner,SG2,,,,,,,Kann, + 29,Ansprechpartner,SG2,CTA,,00006,,,,Muss, + 30,Ansprechpartner,SG2,CTA,3139,00006,,,,IC, + 31,Ansprechpartner,SG2,CTA,3412,00006,,,Kontakt,X, + 32,Kommunikationsverbindung,SG2,COM,,00007,,,,Muss, + 33,Kommunikationsverbindung,SG2,COM,3148,00007,,,Nummer / E-Mail Adresse,X, + 34,Kommunikationsverbindung,SG2,COM,3155,00007,EM,,E-Mail,X [1P0..1], + 35,Kommunikationsverbindung,SG2,COM,3155,,FX,,Telefax,X [1P0..1], + 36,Kommunikationsverbindung,SG2,COM,3155,,TE,,Telefon,X [1P0..1], + 37,Kommunikationsverbindung,SG2,COM,3155,,AJ,,weiteres Telefon,X [1P0..1], + 38,Kommunikationsverbindung,SG2,COM,3155,,AL,,Handy,X [1P0..1], + 39,Sendungsdaten,SG14,,,,,,,Muss, + 40,Sendungsdaten,SG14,CNI,,00019,,,,Muss, + 41,Sendungsdaten,SG14,CNI,1490,00019,,,Vorgangsnummer,X [911],"[911] Format: Mögliche Werte: 1 bis n, je Nachricht bei 1 beginnend und fortlaufend aufsteigend" + 42,Meldepunkt,SG14,LOC,,00020,,,,Muss, + 43,Meldepunkt,SG14,LOC,3227,00020,,,,172, + 44,Meldepunkt,SG14,LOC,3225,00020,,,Identifikator,X [950] [506],"[506] Hinweis: Verwendung der ID der Marktlokation + [950] Format: Marktlokations-ID" + 45,Auftragstatus Sperren,SG15,,,,,,,Muss [78],[78] Wenn STS+Z38 in dieser SG14 nicht vorhanden + 46,Auftragstatus Sperren,SG15,STS,,00103,,,,Muss, + 47,Auftragstatus Sperren,SG15,STS,9015,00103,Z37,,Auftragsstatus Sperren,X, + 48,Auftragstatus Sperren,SG15,STS,4405,00103,Z13,,gescheitert,X ([91] ⊻ [133]) ∧ [20], + 49,Auftragstatus Sperren,SG15,STS,4405,,Z14,,erfolgreich,X [91] ⊻ [133], + 50,Auftragstatus Sperren,SG15,STS,4405,,Z32,,abgelehnt,X [92] ⊻ [134],"[20] Wenn MP-ID in SG1 NAD+MR in der Rolle LF + [91] Wenn in diesem STS DE1131 = E_0472 + [92] Wenn in diesem STS DE1131 = E_0501 + [133] Wenn in diesem STS DE1131 = E_1003 + [134] Wenn in diesem STS DE1131 = E_1002" + 51,Auftragstatus Sperren,SG15,STS,9013,00103,,,Code des Prüfschritts,X ([93] ⊻ [94] ⊻ [107]),"[93] Wenn STS+Z37+Z13 vorhanden, dann sind nur Codes aus dem EBD-Cluster gescheitert möglich. + [94] Wenn STS+Z37+Z14 vorhanden, dann sind nur Codes aus dem EBD-Cluster erfolgreich möglich. + [107] Wenn STS+Z37+Z32 vorhanden, dann sind nur Codes aus dem EBD-Cluster Ablehnung möglich." + 52,Auftragstatus Sperren,SG15,STS,1131,00103,E_0472,,EBD Nr. E_0472,X, + 53,Auftragstatus Sperren,SG15,STS,1131,,E_0501,,EBD Nr. E_0501,X [20], + 54,Auftragstatus Sperren,SG15,STS,1131,,E_1002,,EBD Nr. E_1002,X [20], + 55,Auftragstatus Sperren,SG15,STS,1131,,E_1003,,EBD Nr. E_1003,X,[20] Wenn MP-ID in SG1 NAD+MR in der Rolle LF + 56,Prüfidentifikator,SG15,RFF,,00104,,,,Muss, + 57,Prüfidentifikator,SG15,RFF,1153,00104,Z13,,Prüfidentifikator,X, + 58,Prüfidentifikator,SG15,RFF,1154,00104,21039,,"GPKE, Awh Sperrp. Gas /Auftragsstatus (Sperren)",X, + 59,Datum/Uhrzeit/Zeitspanne,SG15,DTM,,00105,,,,Muss [77],[77] Wenn STS+Z37+Z14 in dieser SG14 vorhanden + 60,Datum/Uhrzeit/Zeitspanne,SG15,DTM,2005,00105,293,,Fertigstellungsdatum/-zeit,X, + 61,Datum/Uhrzeit/Zeitspanne,SG15,DTM,2380,00105,,,"Datum oder Uhrzeit oderZeitspanne, Wert",X [931] [495],"[495] Der Zeitpunkt muss ≤ dem Wert im DE2380 des DTM+137 sein + [931] Format: ZZZ = +00" + 62,Datum/Uhrzeit/Zeitspanne,SG15,DTM,2379,00105,303,,CCYYMMDDHHMMZZZ,X, + 63,Sendungspositionseinzelhei ten,SG25,,,,,,,Muss ([83] ⊻ [85] ⊻ [131] ⊻[132]),"[83] Wenn STS+Z37+Z13+A04/ A05/A06:E_0472 in dieser SG14 vorhanden + [85] Wenn STS+Z37+Z32+A01: E_0501 in dieser SG14 vorhanden + [131] Wenn STS+Z37+Z13+A04/ A05/A06:E_1003 in dieser SG14 vorhanden + [132] Wenn STS+Z37+Z32+A01: E_1002 in dieser SG14 vorhanden" + 64,Sendungspositionseinzelhei ten,SG25,GID,,00106,,,,Muss, + 65,Sendungspositionseinzelhei ten,SG25,GID,1496,00106,,,Sendungsposition,X [903],[903] Format: Möglicher Wert: 1 + 66,Freier Text,SG25,FTX,,00107,,,,Muss, + 67,Freier Text,SG25,FTX,4451,00107,(für allgemeine Hinweise),,,ACB, + 68,Freier Text,SG25,FTX,4440,00107,,,Freier Text,X, + 69,Auftragstatus Entsperren,SG15,,,,,,,Muss [79],[79] Wenn STS+Z37 in dieser SG14 nicht vorhanden + 70,Auftragstatus Entsperren,SG15,STS,,00108,,,,Muss, + 71,Auftragstatus Entsperren,SG15,STS,9015,00108,Z38,,Auftragsstatus Entsperren,X, + 72,Auftragstatus Entsperren,SG15,STS,4405,00108,Z13,,gescheitert,X [95] ⊻ [137], + 73,Auftragstatus Entsperren,SG15,STS,4405,,Z14,,erfolgreich,X [95] ⊻ [137] ⊻ [96] ⊻[138],"[95] Wenn in diesem STS DE1131 = E_0499 + [96] Wenn in diesem STS DE1131 = E_0487 + [137] Wenn in diesem STS DE1131 = E_1005 + [138] Wenn in diesem STS DE1131 = E_1020" + 74,Auftragstatus Entsperren,SG15,STS,9013,00108,,,Code des Prüfschritts,X ((([97] ⊻ [98]) ∧ ([95] ⊻[137])) ⊻ [99] ⊻ [139]),"[95] Wenn in diesem STS DE1131 = E_0499 + [97] Wenn STS+Z38+Z13 vorhanden, dann sind nur Codes aus dem EBD-Cluster gescheitert möglich. + [98] Wenn STS+Z38+Z14" + 75,Auftragstatus Entsperren,SG15,STS,1131,00108,E_0487,,EBD Nr. E_0487,X, + 76,Auftragstatus Entsperren,SG15,STS,1131,,E_0499,,EBD Nr. E_0499,X, + 77,Auftragstatus Entsperren,SG15,STS,1131,,E_1005,,EBD Nr. E_1005,X, + 78,Auftragstatus Entsperren,SG15,STS,1131,,E_1020,,EBD Nr. E_1020,X, + 79,Prüfidentifikator,SG15,RFF,,00109,,,,Muss, + 80,Prüfidentifikator,SG15,RFF,1153,00109,Z13,,Prüfidentifikator,X, + 81,Prüfidentifikator,SG15,RFF,1154,00109,21039,,"GPKE, Awh Sperrp. Gas /Auftragsstatus (Sperren)",X, + 82,Datum/Uhrzeit/Zeitspanne,SG15,DTM,,00110,,,,Muss [80],[80] Wenn STS+Z38+Z14 in dieser SG14 vorhanden + 83,Datum/Uhrzeit/Zeitspanne,SG15,DTM,2005,00110,293,,Fertigstellungsdatum/-zeit,X, + 84,Datum/Uhrzeit/Zeitspanne,SG15,DTM,2380,00110,,,"Datum oder Uhrzeit oderZeitspanne, Wert",X [931] [495],"[495] Der Zeitpunkt muss ≤ dem Wert im DE2380 des DTM+137 sein + [931] Format: ZZZ = +00" + 85,Datum/Uhrzeit/Zeitspanne,SG15,DTM,2379,00110,303,,CCYYMMDDHHMMZZZ,X, + 86,Sendungspositionseinzelhei ten,SG25,,,,,,,Muss [84] ⊻ [136],"[84] Wenn STS+Z38+Z13+A02: E_0499 in dieser SG14 vorhanden + [136] Wenn STS+Z38+Z13+A02: E_1005 in dieser SG14 vorhanden" + 87,Sendungspositionseinzelhei ten,SG25,GID,,00111,,,,Muss, + 88,Sendungspositionseinzelhei ten,SG25,GID,1496,00111,,,Sendungsposition,X [903],[903] Format: Möglicher Wert: 1 + 89,Freier Text,SG25,FTX,,00112,,,,Muss, + 90,Freier Text,SG25,FTX,4451,00112,(für allgemeine Hinweise),,,ACB, + 91,Freier Text,SG25,FTX,4440,00112,,,Freier Text,X, + 92,Nachrichten-Endesegment,,UNT,,00126,,,,Muss, + 93,Nachrichten-Endesegment,,UNT,0074,00126,,,Anzahl der Segmente in einerNachricht,X, + 94,Nachrichten-Endesegment,,UNT,0062,00126,,,Nachrichten-Referenznummer,X, + + ''' +# --- +# name: TestCli.test_kohlrahbi_cli_with_valid_arguments[23001] + ''' + ,Segmentname,Segmentgruppe,Segment,Datenelement,Segment ID,Code,Qualifier,Beschreibung,Bedingungsausdruck,Bedingung + 0,Nachrichten-Kopfsegment,,UNH,,00001,,,,Muss, + 1,Nachrichten-Kopfsegment,,UNH,0062,00001,,,Nachrichten-Referenznummer,X, + 2,Nachrichten-Kopfsegment,,UNH,0065,00001,INSRPT,,Prüfbericht,X, + 3,Nachrichten-Kopfsegment,,UNH,0052,00001,D,,Entwurfs-Version,X, + 4,Nachrichten-Kopfsegment,,UNH,0054,00001,10A,,Ausgabe 2010 - A,X, + 5,Nachrichten-Kopfsegment,,UNH,0051,00001,UN,,UN/CEFACT,X, + 6,Nachrichten-Kopfsegment,,UNH,0057,00001,1.1a,,VersionsnummerderzugrundeliegendenBDEW-Nachrichtenbeschreibung,X, + 7,Beginn der Nachricht,,BGM,,00002,,,,Muss, + 8,Beginn der Nachricht,,BGM,1001,00002,4,,Prüfbericht,X, + 9,Beginn der Nachricht,,BGM,1004,00002,,,Dokumentennummer,X, + 10,Dokumentendatum,,DTM,,00003,,,,Muss, + 11,Dokumentendatum,,DTM,2005,00003,137,,Dokumenten-/Nachrichtendatum/-zeit,X, + 12,Dokumentendatum,,DTM,2380,00003,,,"Datum oder Uhrzeit oderZeitspanne, Wert",X [931][494],"[494] Das hier genannte Datum muss der Zeitpunkt sein, zu dem das Dokument erstellt wurde, oder ein Zeitpunkt, der davor liegt + [931] Format: ZZZ = +00" + 13,Dokumentendatum,,DTM,2379,00003,303,,CCYYMMDDHHMMZZZ,X, + 14,MP-ID Empfänger,SG2,,,,,,,Muss, + 15,MP-ID Empfänger,SG2,NAD,,00004,,,,Muss, + 16,MP-ID Empfänger,SG2,NAD,3035,00004,MR,,Nachrichtenempfänger,X, + 17,MP-ID Empfänger,SG2,NAD,3039,00004,,,MP-ID,X, + 18,MP-ID Empfänger,SG2,NAD,3055,00004,9,,GS1,X, + 19,MP-ID Empfänger,SG2,NAD,3055,,293,,"DE, BDEW(Bundesverband derEnergie- undWasserwirtschafte.V.)",X, + 20,MP-ID Empfänger,SG2,NAD,3055,,332,,"DE, DVGW Service &Consult GmbH",X, + 21,MP-ID Absender,SG2,,,,,,,Muss, + 22,MP-ID Absender,SG2,NAD,,00005,,,,Muss, + 23,MP-ID Absender,SG2,NAD,3035,00005,MS,,Dokumenten-/Nachrichtenaussteller bzw. -absender,X, + 24,MP-ID Absender,SG2,NAD,3039,00005,,,MP-ID,X, + 25,MP-ID Absender,SG2,NAD,3055,00005,9,,GS1,X, + 26,MP-ID Absender,SG2,NAD,3055,,293,,"DE, BDEW(Bundesverband derEnergie- undWasserwirtschafte.V.)",X, + 27,MP-ID Absender,SG2,NAD,3055,,332,,"DE, DVGW Service &Consult GmbH",X, + 28,Dokument-/Nachricht- Einzelheiten,SG3,,,,,,,Muss, + 29,Dokument-/Nachricht- Einzelheiten,SG3,DOC,,00006,,,,Muss, + 30,Dokument-/Nachricht- Einzelheiten,SG3,DOC,1001,00006,21,,Anfrage,X, + 31,Dokument-/Nachricht- Einzelheiten,SG3,DOC,1001,,22,,Antwort auf Anfrage,, + 32,Dokument-/Nachricht- Einzelheiten,SG3,DOC,1001,,293,,Prüfbericht,, + 33,Dokument-/Nachricht- Einzelheiten,SG3,DOC,1004,00006,,,Vorgangsnummer,X, + 34,Prüfidentifikator,SG4,,,,,,,Muss, + 35,Prüfidentifikator,SG4,RFF,,00007,,,,Muss, + 36,Prüfidentifikator,SG4,RFF,1153,00007,Z13,,Prüfidentifikator,X, + 37,Prüfidentifikator,SG4,RFF,1154,00007,23001,,WiM /Störungsmeldungvom LF/NB/MSB anMSB,X, + 38,Prüfidentifikator,SG4,RFF,1154,,23003,,WiM / Ablehnungvom MSB an LF/NB/MSB,, + 39,Prüfidentifikator,SG4,RFF,1154,,23004,,WiM / Bestätigungvom MSB an LF/NB/MSB,, + 40,Prüfidentifikator,SG4,RFF,1154,,23008,,WiM /Ergebnisbericht vomMSB an LF/NB/MSB,, + 41,Referenzangaben,SG4,,,,,,,, + 42,Referenzangaben,SG4,RFF,,00008,,,,, + 43,Referenzangaben,SG4,RFF,1153,00008,AAV,,Nummer derAnfrage,, + 44,Referenzangaben,SG4,RFF,1153,,TN,,Transaktions-Referenznummer,, + 45,Referenzangaben,SG4,RFF,1154,00008,,,Dokumenten-/Vorgangsnummer derBezugsnachricht,,[500] Hinweis: Vorgangsnummer (DOC DE1004) aus Prozessschritt 4b „Bestätigung der Störungsmeldung“ (Gas) bzw. Prozessschritt 2 „Antwort“ (Strom). + 46,Ansprechpartner beim Nachrichtenabsender,SG5,,,,,,,Muss, + 47,Ansprechpartner beim Nachrichtenabsender,SG5,NAD,,00009,,,,Muss, + 48,Ansprechpartner beim Nachrichtenabsender,SG5,NAD,3035,00009,MS,,Dokumenten-/Nachrichtenaussteller bzw. -absender,X, + 49,Ansprechpartner beim Nachrichtenabsender,SG5,NAD,3039,00009,,,MP-ID,X, + 50,Ansprechpartner beim Nachrichtenabsender,SG5,NAD,3055,00009,9,,GS1,X, + 51,Ansprechpartner beim Nachrichtenabsender,SG5,NAD,3055,,293,,"DE, BDEW(Bundesverband derEnergie- undWasserwirtschafte.V.)",X, + 52,Ansprechpartner beim Nachrichtenabsender,SG5,NAD,3055,,332,,"DE, DVGW Service &Consult GmbH",X, + 53,Ansprechpartner,SG6,,,,,,,Muss, + 54,Ansprechpartner,SG6,CTA,,00010,,,,Muss, + 55,Ansprechpartner,SG6,CTA,3139,00010,IC,,Informationskontakt,X, + 56,Ansprechpartner,SG6,CTA,3412,00010,,,Kontakt,X, + 57,Kommunikationsverbindu ng,SG6,COM,,00011,,,,Muss, + 58,Kommunikationsverbindu ng,SG6,COM,3148,00011,,,"Kommunikationsadresse,Identifikation",X, + 59,Kommunikationsverbindu ng,SG6,COM,3155,00011,EM,,E-Mail,X [1P0..1], + 60,Kommunikationsverbindu ng,SG6,COM,3155,,FX,,Telefax,X [1P0..1], + 61,Kommunikationsverbindu ng,SG6,COM,3155,,TE,,Telefon,X [1P0..1], + 62,Kommunikationsverbindu ng,SG6,COM,3155,,AJ,,weiteres Telefon,X [1P0..1], + 63,Kommunikationsverbindu ng,SG6,COM,3155,,AL,,Handy,X [1P0..1], + 64,Ansprechpartner beim Kunden,SG5,,,,,,,Soll [1],[1] Wenn Nachrichtenabsender vom Kunden informiert wurde. + 65,Ansprechpartner beim Kunden,SG5,NAD,,00012,,,,Muss, + 66,Ansprechpartner beim Kunden,SG5,NAD,3035,00012,CC,,Anspruchsteller,X, + 67,Ansprechpartner,SG6,,,,,,,Muss, + 68,Ansprechpartner,SG6,CTA,,00013,,,,Muss, + 69,Ansprechpartner,SG6,CTA,3139,00013,IC,,Informationskontakt,X, + 70,Ansprechpartner,SG6,CTA,3412,00013,,,Kontakt,X, + 71,Kommunikationsverbindu ng,SG6,COM,,00014,,,,Muss, + 72,Kommunikationsverbindu ng,SG6,COM,3148,00014,,,"Kommunikationsadresse,Identifikation",X, + 73,Kommunikationsverbindu ng,SG6,COM,3155,00014,EM,,E-Mail,X [1P0..1], + 74,Kommunikationsverbindu ng,SG6,COM,3155,,FX,,Telefax,X [1P0..1], + 75,Kommunikationsverbindu ng,SG6,COM,3155,,TE,,Telefon,X [1P0..1], + 76,Kommunikationsverbindu ng,SG6,COM,3155,,AJ,,weiteres Telefon,X [1P0..1], + 77,Kommunikationsverbindu ng,SG6,COM,3155,,AL,,Handy,X [1P0..1], + 78,Positionsdaten,SG7,,,,,,,Muss,"[512] Hinweis: Wurde eine Störung festgestellt und durch den MSB behoben, ist die Segmentgruppe mit demselben Meldepunkt zweimal anzugeben + [513] Hinweis: Wurde keine Störung festgestellt, ist die Segmentgruppe genau einmal anzugeben + [514] Hinweis: Wurde eine Störung festgestellt, die nicht durch den MSB behoben werden konnte, ist die Segmentgruppe genau einmal anzugeben" + 79,Positionsdaten,SG7,LIN,,00015,,,,Muss, + 80,Positionsdaten,SG7,LIN,1082,00015,,,Positionsnummer,X [908][511],"[511] Hinweis: Die Nummerierung beginnt in jedem Dokument bei 1 + [908] Format: Mögliche Werte: 1 bis n" + 81,Zeitpunkt zu dem der Geräte-Status ermittelt wurde,SG7,DTM,,00016,,,,,"[6] Wenn keine Störung festgestellt werden konnte. + [9] Wenn eine Störung festgestellt wurde, die durch den MSB selbständig und unverschuldet nicht behoben werden konnte." + 82,Zeitpunkt zu dem der Geräte-Status ermittelt wurde,SG7,DTM,2005,00016,9,,Bearbeitungs-/Verarbeitungsdatum/-zeit,, + 83,Zeitpunkt zu dem der Geräte-Status ermittelt wurde,SG7,DTM,2380,00016,,,"Datum oder Uhrzeit oderZeitspanne, Wert",,[13] Wenn DE2379 = 303 + 84,Zeitpunkt zu dem der Geräte-Status ermittelt wurde,SG7,DTM,2379,00016,102,,CCYYMMDD,, + 85,Zeitpunkt zu dem der Geräte-Status ermittelt wurde,SG7,DTM,2379,,303,,CCYYMMDDHHMMZZZ,, + 86,Beginn des Geräte-Status,SG7,DTM,,00017,,,,Kann,[7] Wenn keine weitere SG7 mit demselben Meldepunkt und DTM+9 vorhanden + 87,Beginn des Geräte-Status,SG7,DTM,2005,00017,163,,"Verarbeitung,Beginndatum/-zeit",X, + 88,Beginn des Geräte-Status,SG7,DTM,2380,00017,,,"Datum oder Uhrzeit oderZeitspanne, Wert",X ([931][13] ∧[495]) ⊻([495] ∧[515]),"[13] Wenn DE2379 = 303 + [495] Der Zeitpunkt muss ≤ dem Wert im DE2380 des DTM+137 sein + [515] Hinweis: ""≤ dem Wert im DE2380 des DTM+137"" bedeutet, dass der dort genannte Tag ≥ dem in diesem DTM genannten Tag sein muss, wenn in DE2379 der Code 102 steht. + [931] Format: ZZZ = +00" + 89,Beginn des Geräte-Status,SG7,DTM,2379,00017,102,,CCYYMMDD,X, + 90,Beginn des Geräte-Status,SG7,DTM,2379,,303,,CCYYMMDDHHMMZZZ,X, + 91,Ende des Geräte-Status,SG7,DTM,,00018,,,,,[8] Wenn in dieser SG7 STS+Z06+Z10 vorhanden + 92,Ende des Geräte-Status,SG7,DTM,2005,00018,164,,"Verarbeitung,Endedatum/-zeit",, + 93,Ende des Geräte-Status,SG7,DTM,2380,00018,,,"Datum oder Uhrzeit oderZeitspanne, Wert",,"[13] Wenn DE2379 = 303 + [495] Der Zeitpunkt muss ≤ dem Wert im DE2380 des DTM+137 sein + [515] Hinweis: ""≤ dem Wert im DE2380 des DTM+137"" bedeutet, dass der dort genannte Tag ≥ dem in diesem DTM genannten Tag sein muss, wenn in DE2379 der Code 102 steht. + [931] Format: ZZZ = +00" + 94,Ende des Geräte-Status,SG7,DTM,2379,00018,102,,CCYYMMDD,, + 95,Ende des Geräte-Status,SG7,DTM,2379,,303,,CCYYMMDDHHMMZZZ,, + 96,Ende des Zustands,SG7,DTM,,00019,,,,, + 97,Ende des Zustands,SG7,DTM,2005,00019,292,,"Datum/Zeit derabgeschlossenenLeistung (Arbeit),geplant",, + 98,Ende des Zustands,SG7,DTM,2380,00019,,,"Datum oder Uhrzeit oderZeitspanne, Wert",,"[13] Wenn DE2379 = 303 + [931] Format: ZZZ = +00" + 99,Ende des Zustands,SG7,DTM,2379,00019,102,,CCYYMMDD,, + 100,Ende des Zustands,SG7,DTM,2379,,303,,CCYYMMDDHHMMZZZ,, + 101,Gerätestatus,SG7,STS,,00020,,,,Muss, + 102,Gerätestatus,SG7,STS,9015,00020,Z06,,Gerätestatus,X, + 103,Gerätestatus,SG7,STS,4405,00020,Z09,,störungsfrei,, + 104,Gerätestatus,SG7,STS,4405,,Z10,,gestört,, + 105,Gerätestatus,SG7,STS,4405,,Z11,,festgestellte Störung,X, + 106,Gerätestatus,SG7,STS,4405,,Z12,,vermutete Störung,X, + 107,Gerätestatus,SG7,STS,9013,00020,Z75,,Kommunikationsstörung,, + 108,Gerätestatus,SG7,STS,9013,,Z78,,Gerätewechsel,, + 109,Gerätestatus,SG7,STS,9013,,Z81,,Messeinrichtunggestört/defekt,, + 110,Gerätestatus,SG7,STS,9013,,ZB8,,keine Störung,, + 111,Gerätestatus,SG7,STS,9013,,ZC1,,Störungsbehebung,,"[6] Wenn keine Störung festgestellt werden konnte. + [10] Wenn in diesem STS DE4405 = Z09 + [11] Wenn in diesem STS DE4405 = Z10 + [12] Wenn eine Störung festgestellt wurde, die durch den" + 112,Antwortstatus,SG7,STS,,00021,,,,, + 113,Antwortstatus,SG7,STS,9015,00021,E01,,Status der Antwort,, + 114,Antwortstatus,SG7,STS,9013,00021,E15,,Zustimmung ohneKorrekturen,, + 115,Antwortstatus,SG7,STS,9013,,Z29,,Ablehnung (keinVertragsverhältnismehr vorhanden),, + 116,Antwortstatus,SG7,STS,9013,,ZB8,,keine Störungfeststellbar,, + 117,Freier Text,SG7,FTX,,00022,,,,Kann,[2] Wenn SG7 STS+Z06+Z10+ZC1 vorhanden. + 118,Freier Text,SG7,FTX,4451,00022,AAO,,Fehlerbeschreibung(Freier Text),, + 119,Freier Text,SG7,FTX,4451,,ACD,,Begründung,X, + 120,Freier Text,SG7,FTX,4440,00022,,,Freier Text,X, + 121,Messlokation,SG8,,,,,,,Muss, + 122,Messlokation,SG8,NAD,,00023,,,,Muss, + 123,Messlokation,SG8,NAD,3035,00023,DP,,Lieferanschrift,X, + 124,Meldepunkt,SG8,LOC,,00024,,,,Muss, + 125,Meldepunkt,SG8,LOC,3227,00024,172,,Meldepunkt,X, + 126,Meldepunkt,SG8,LOC,3225,00024,,,Identifikator,X [951][509],"[509] Hinweis: Verwendung der ID der Messlokation + [951] Format: Zählpunktbezeichnung" + 127,Nachrichten- Endesegment,,UNT,,00026,,,,Muss, + 128,Nachrichten- Endesegment,,UNT,0074,00026,,,Anzahl der Segmente ineiner Nachricht,X, + 129,Nachrichten- Endesegment,,UNT,0062,00026,,,Nachrichten-Referenznummer,X, + + ''' +# --- +# name: TestCli.test_kohlrahbi_cli_with_valid_arguments[23009] + ''' + ,Segmentname,Segmentgruppe,Segment,Datenelement,Segment ID,Code,Qualifier,Beschreibung,Bedingungsausdruck,Bedingung + 0,Nachrichten-Kopfsegment,,UNH,,00001,,,,Muss, + 1,Nachrichten-Kopfsegment,,UNH,0062,00001,,,Nachrichten-Referenznummer,X, + 2,Nachrichten-Kopfsegment,,UNH,0065,00001,INSRPT,,Prüfbericht,X, + 3,Nachrichten-Kopfsegment,,UNH,0052,00001,D,,Entwurfs-Version,X, + 4,Nachrichten-Kopfsegment,,UNH,0054,00001,10A,,Ausgabe 2010 - A,X, + 5,Nachrichten-Kopfsegment,,UNH,0051,00001,UN,,UN/CEFACT,X, + 6,Nachrichten-Kopfsegment,,UNH,0057,00001,1.1a,,Versionsnummer derzugrundeliegendenBDEW-Nachrichtenbeschreibung,X, + 7,Beginn der Nachricht,,BGM,,00002,,,,Muss, + 8,Beginn der Nachricht,,BGM,1001,00002,4,,Prüfbericht,X, + 9,Beginn der Nachricht,,BGM,1004,00002,,,Dokumentennummer,X, + 10,Dokumentendatum,,DTM,,00003,,,,Muss, + 11,Dokumentendatum,,DTM,2005,00003,137,,Dokumenten-/Nachrichtendatum/-zeit,X, + 12,Dokumentendatum,,DTM,2380,00003,,,"Datum oder Uhrzeit oderZeitspanne, Wert",X [931] [494],"[494] Das hier genannte Datum muss der Zeitpunkt sein, zu dem das Dokument erstellt wurde, oder ein Zeitpunkt, der davor liegt + [931] Format: ZZZ = +00" + 13,Dokumentendatum,,DTM,2379,00003,303,,CCYYMMDDHHMMZZZ,X, + 14,MP-ID Empfänger,SG2,,,,,,,Muss, + 15,MP-ID Empfänger,SG2,NAD,,00004,,,,Muss, + 16,MP-ID Empfänger,SG2,NAD,3035,00004,MR,,Nachrichtenempfänger,X, + 17,MP-ID Empfänger,SG2,NAD,3039,00004,,,MP-ID,X, + 18,MP-ID Empfänger,SG2,NAD,3055,00004,9,,GS1,X, + 19,MP-ID Empfänger,SG2,NAD,3055,,293,,"DE, BDEW(Bundesverband derEnergie- undWasserwirtschaft e.V.)",X, + 20,MP-ID Empfänger,SG2,NAD,3055,,332,,"DE, DVGW Service &Consult GmbH",X, + 21,MP-ID Absender,SG2,,,,,,,Muss, + 22,MP-ID Absender,SG2,NAD,,00005,,,,Muss, + 23,MP-ID Absender,SG2,NAD,3035,00005,MS,,Dokumenten-/Nachrichtenausstellerbzw. -absender,X, + 24,MP-ID Absender,SG2,NAD,3039,00005,,,MP-ID,X, + 25,MP-ID Absender,SG2,NAD,3055,00005,9,,GS1,X, + 26,MP-ID Absender,SG2,NAD,3055,,293,,"DE, BDEW(Bundesverband derEnergie- undWasserwirtschaft e.V.)",X, + 27,Dokument-/Nachricht- Einzelheiten,SG3,,,,,,,Muss, + 28,Dokument-/Nachricht- Einzelheiten,SG3,DOC,,00006,,,,Muss, + 29,Dokument-/Nachricht- Einzelheiten,SG3,DOC,1001,00006,23,,Statusinformationen,, + 30,Dokument-/Nachricht- Einzelheiten,SG3,DOC,1001,,293,,Prüfbericht,X, + 31,Dokument-/Nachricht- Einzelheiten,SG3,DOC,1004,00006,,,Vorgangsnummer,X, + 32,Prüfidentifikator,SG4,,,,,,,Muss, + 33,Prüfidentifikator,SG4,RFF,,00007,,,,Muss, + 34,Prüfidentifikator,SG4,RFF,1153,00007,Z13,,Prüfidentifikator,X, + 35,Prüfidentifikator,SG4,RFF,1154,00007,23005,,WiM /Informationsmeldung(Störungsmeldung) vomMSB an NB (Gas)/MSB(Strom),, + 36,Prüfidentifikator,SG4,RFF,1154,,23009,,WiM /Informationsmeldung(Störungsbehebung) vomMSB an NB (Gas)/MSB(Strom),X, + 37,Referenzangaben,SG4,,,,,,,Muss, + 38,Referenzangaben,SG4,RFF,,00008,,,,Muss, + 39,Referenzangaben,SG4,RFF,1153,00008,TN,,Transaktions-Referenznummer,X, + 40,Referenzangaben,SG4,RFF,1154,00008,,,Dokumenten-/Vorgangsnummerder Bezugsnachricht,X [508],[508] Hinweis: Vorgangsnummer aus DOC DE1004. + 41,Positionsdaten,SG7,,,,,,,Muss, + 42,Positionsdaten,SG7,LIN,,00015,,,,Muss, + 43,Positionsdaten,SG7,LIN,1082,00015,,,Positionsnummer,X [908] [511],"[511] Hinweis: Die Nummerierung beginnt in jedem Dokument bei 1 + [908] Format: Mögliche Werte: 1 bis n" + 44,Zeitpunkt zu dem der Geräte-Status ermittelt wurde,SG7,DTM,,00016,,,,Soll [3],[3] Wenn vorhanden. + 45,Zeitpunkt zu dem der Geräte-Status ermittelt wurde,SG7,DTM,2005,00016,9,,Bearbeitungs-/Verarbeitungsdatum/-zeit,X, + 46,Zeitpunkt zu dem der Geräte-Status ermittelt wurde,SG7,DTM,2380,00016,,,"Datum oder Uhrzeit oderZeitspanne, Wert",X ([931] [13] ∧[495]) ⊻ ([495]∧ [515]),"[13] Wenn DE2379 = 303 + [495] Der Zeitpunkt muss ≤ dem Wert im DE2380 des DTM+137 sein + [515] Hinweis: ""≤ dem Wert" + 47,Zeitpunkt zu dem der Geräte-Status ermittelt wurde,SG7,DTM,2379,00016,102,,CCYYMMDD,X, + 48,Zeitpunkt zu dem der Geräte-Status ermittelt wurde,SG7,DTM,2379,,303,,CCYYMMDDHHMMZZZ,X, + 49,Beginn des Geräte-Status,SG7,DTM,,00017,,,,Kann, + 50,Beginn des Geräte-Status,SG7,DTM,2005,00017,163,,"Verarbeitung,Beginndatum/-zeit",X, + 51,Beginn des Geräte-Status,SG7,DTM,2380,00017,,,"Datum oder Uhrzeit oderZeitspanne, Wert",X ([931] [13] ∧[495]) ⊻ ([495]∧ [515]),"[13] Wenn DE2379 = 303 + [495] Der Zeitpunkt muss ≤ dem Wert im DE2380 des DTM+137 sein + [515] Hinweis: ""≤ dem Wert im DE2380 des DTM+137"" bedeutet, dass der dort genannte Tag ≥ dem in diesem DTM genannten Tag sein muss, wenn in DE2379 der Code 102 steht. + [931] Format: ZZZ = +00" + 52,Beginn des Geräte-Status,SG7,DTM,2379,00017,102,,CCYYMMDD,X, + 53,Beginn des Geräte-Status,SG7,DTM,2379,,303,,CCYYMMDDHHMMZZZ,X, + 54,Ende des Geräte-Status,SG7,DTM,,00018,,,,Muss, + 55,Ende des Geräte-Status,SG7,DTM,2005,00018,164,,"Verarbeitung,Endedatum/-zeit",X, + 56,Ende des Geräte-Status,SG7,DTM,2380,00018,,,"Datum oder Uhrzeit oderZeitspanne, Wert",X ([931] [13] ∧[495]) ⊻ ([495]∧ [515]),"[13] Wenn DE2379 = 303 + [495] Der Zeitpunkt muss ≤ dem Wert im DE2380 des DTM+137 sein + [515] Hinweis: ""≤ dem Wert im DE2380 des DTM+137"" bedeutet, dass der dort genannte Tag ≥ dem in diesem DTM genannten Tag sein muss, wenn in DE2379 der Code 102 steht. + [931] Format: ZZZ = +00" + 57,Ende des Geräte-Status,SG7,DTM,2379,00018,102,,CCYYMMDD,X, + 58,Ende des Geräte-Status,SG7,DTM,2379,,303,,CCYYMMDDHHMMZZZ,X, + 59,Ende des Zustands,SG7,DTM,,00019,,,,, + 60,Ende des Zustands,SG7,DTM,2005,00019,292,,"Datum/Zeit derabgeschlossenenLeistung (Arbeit), geplant",, + 61,Ende des Zustands,SG7,DTM,2380,00019,,,"Datum oder Uhrzeit oderZeitspanne, Wert",,"[13] Wenn DE2379 = 303 + [931] Format: ZZZ = +00" + 62,Ende des Zustands,SG7,DTM,2379,00019,102,,CCYYMMDD,, + 63,Ende des Zustands,SG7,DTM,2379,,303,,CCYYMMDDHHMMZZZ,, + 64,Gerätestatus,SG7,STS,,00020,,,,Muss, + 65,Gerätestatus,SG7,STS,9015,00020,Z06,,Gerätestatus,X, + 66,Gerätestatus,SG7,STS,4405,00020,Z09,,störungsfrei,X, + 67,Gerätestatus,SG7,STS,4405,,Z10,,gestört,X, + 68,Gerätestatus,SG7,STS,9013,00020,Z75,,Kommunikationsstörung,X, + 69,Gerätestatus,SG7,STS,9013,,Z78,,Gerätewechsel,X, + 70,Gerätestatus,SG7,STS,9013,,Z81,,Messeinrichtunggestört/defekt,X, + 71,Gerätestatus,SG7,STS,9013,,ZB8,,keine Störungfeststellbar,X, + 72,Gerätestatus,SG7,STS,9013,,ZC1,,Störungsbehebung nichtmöglich,X [506] ∧ [507],"[506] Hinweis: Zu nutzen, wenn Behebung der Störung durch den MSB selbständig und unverschuldet nicht möglich ist. + [507] Hinweis: In SG7 FTX+AAO ist anzugeben, was die übergeordnete Ursache ist, aufgrund derer der MSB nicht in der Lage ist die Störung zu beheben." + 73,Freier Text,SG7,FTX,,00022,,,,Muss [2],[2] Wenn SG7 STS+Z06+Z10+ZC1 vorhanden. + 74,Freier Text,SG7,FTX,4451,00022,AAO,,Fehlerbeschreibung(Freier Text),X, + 75,Freier Text,SG7,FTX,4440,00022,,,Freier Text,X, + 76,Messlokation,SG8,,,,,,,Muss, + 77,Messlokation,SG8,NAD,,00023,,,,Muss, + 78,Messlokation,SG8,NAD,3035,00023,DP,,Lieferanschrift,X, + 79,Meldepunkt,SG8,LOC,,00024,,,,Muss, + 80,Meldepunkt,SG8,LOC,3227,00024,172,,Meldepunkt,X, + 81,Meldepunkt,SG8,LOC,3225,00024,,,Identifikator,X [951] [509],"[509] Hinweis: Verwendung der ID der Messlokation + [951] Format: Zählpunktbezeichnung" + 82,Nachrichten-Endesegment,,UNT,,00026,,,,Muss, + 83,Nachrichten-Endesegment,,UNT,0074,00026,,,Anzahl der Segmente in einerNachricht,X, + 84,Nachrichten-Endesegment,,UNT,0062,00026,,,Nachrichten-Referenznummer,X, + + ''' +# --- +# name: TestCli.test_kohlrahbi_cli_with_valid_arguments[25001] + ''' + ,Segmentname,Segmentgruppe,Segment,Datenelement,Segment ID,Code,Qualifier,Beschreibung,Bedingungsausdruck,Bedingung + 0,Nachrichten-Kopfsegment,,UNH,,00001,,,,Muss, + 1,Nachrichten-Kopfsegment,,UNH,0062,00001,,,Nachrichten-Referenznummer,X, + 2,Nachrichten-Kopfsegment,,UNH,0065,00001,UTILTS,,Netznutzungszeiten-Nachricht,X, + 3,Nachrichten-Kopfsegment,,UNH,0052,00001,D,,Entwurfs-Version,X, + 4,Nachrichten-Kopfsegment,,UNH,0054,00001,18A,,Ausgabe 2018 - A,X, + 5,Nachrichten-Kopfsegment,,UNH,0051,00001,UN,,UN/CEFACT,X, + 6,Nachrichten-Kopfsegment,,UNH,0057,00001,1.1c,,Versionsnummer derzugrundeliegendenBDEW-Nachrichtenbeschreibung,X, + 7,Beginn der Nachricht,,BGM,,00002,,,,Muss, + 8,Beginn der Nachricht,,BGM,1001,00002,Z36,,Berechnungsformel,X, + 9,Beginn der Nachricht,,BGM,1004,00002,,,Dokumentennummer,X, + 10,Nachrichtendatum,,DTM,,00003,,,,Muss, + 11,Nachrichtendatum,,DTM,2005,00003,137,,Dokumenten-/Nachrichtendatum/-zeit,X, + 12,Nachrichtendatum,,DTM,2380,00003,,,"Datum oder Uhrzeit oderZeitspanne, Wert",X [931][494],"[494] Das hier genannte Datum muss der Zeitpunkt sein, zu dem das Dokument erstellt wurde, oder ein Zeitpunkt, der davor liegt. + [931] Format: ZZZ = +00" + 13,Nachrichtendatum,,DTM,2379,00003,303,,CCYYMMDDHHMMZZZ,X, + 14,MP-ID Absender,SG2,,,,,,,Muss, + 15,MP-ID Absender,SG2,NAD,,00004,,,,Muss, + 16,MP-ID Absender,SG2,NAD,3035,00004,MS,,Dokumenten-/Nachrichtenausstellerbzw. -absender,X, + 17,MP-ID Absender,SG2,NAD,3039,00004,,,MP-ID,X [1],[1] Nur MP-ID aus Sparte Strom + 18,MP-ID Absender,SG2,NAD,3055,00004,9,,GS1,X, + 19,MP-ID Absender,SG2,NAD,3055,,293,,"DE, BDEW(Bundesverband derEnergie- undWasserwirtschaft e.V.)",X, + 20,Ansprechpartner,SG3,,,,,,,Muss [2]Kann,[2] Wenn SG5 STS+Z23+Z34 (Formel muss beim Absender angefragt werden) in einem SG5 IDE vorhanden + 21,Ansprechpartner,SG3,CTA,,00005,,,,Muss, + 22,Ansprechpartner,SG3,CTA,3139,00005,IC,,Informationskontakt,X, + 23,Ansprechpartner,SG3,CTA,3412,00005,,,Name vom Ansprechpartner,X, + 24,Kommunikationsverbindung,SG3,COM,,00006,,,,Muss, + 25,Kommunikationsverbindung,SG3,COM,3148,00006,,,Nummer / Adresse,X, + 26,Kommunikationsverbindung,SG3,COM,3155,00006,EM,,Elektronische Post,X [1P0..1], + 27,Kommunikationsverbindung,SG3,COM,3155,,FX,,Telefax,X [1P0..1], + 28,Kommunikationsverbindung,SG3,COM,3155,,TE,,Telefon,X [1P0..1], + 29,Kommunikationsverbindung,SG3,COM,3155,,AJ,,weiteres Telefon,X [1P0..1], + 30,Kommunikationsverbindung,SG3,COM,3155,,AL,,Handy,X [1P0..1], + 31,MP-ID Empfänger,SG2,,,,,,,Muss, + 32,MP-ID Empfänger,SG2,NAD,,00007,,,,Muss, + 33,MP-ID Empfänger,SG2,NAD,3035,00007,MR,,Nachrichtenempfänger,X, + 34,MP-ID Empfänger,SG2,NAD,3039,00007,,,MP-ID,X [1],[1] Nur MP-ID aus Sparte Strom + 35,MP-ID Empfänger,SG2,NAD,3055,00007,9,,GS1,X, + 36,MP-ID Empfänger,SG2,NAD,3055,,293,,"DE, BDEW(Bundesverband derEnergie- undWasserwirtschaft e.V.)",X, + 37,Vorgang,SG5,,,,,,,Muss, + 38,Vorgang,SG5,IDE,,00008,,,,Muss, + 39,Vorgang,SG5,IDE,7495,00008,24,,Transaktion,X, + 40,Vorgang,SG5,IDE,7402,00008,,,Vorgangsnummer,X, + 41,ID der Marktlokation,SG5,LOC,,00009,,,,Muss, + 42,ID der Marktlokation,SG5,LOC,3227,00009,172,,Meldepunkt,X, + 43,ID der Marktlokation,SG5,LOC,3225,00009,,,ID der Marktlokation,X [950][501],"[501] Hinweis: Verwendung der ID der Marktlokation + [950] Format: Marktlokations-ID" + 44,Gültig ab,SG5,DTM,,00011,,,,Muss, + 45,Gültig ab,SG5,DTM,2005,00011,157,,"Gültigkeit, Beginndatum",X, + 46,Gültig ab,SG5,DTM,2380,00011,,,"Datum oder Uhrzeit oderZeitspanne, Wert",X [931][500] ∧[UB1],"[500] Hinweis: Zeitpunkt, ab dem die Berechnungsformel anzuwenden ist + [931] Format: ZZZ = +00" + 47,Gültig ab,SG5,DTM,2379,00011,303,,CCYYMMDDHHMMZZZ,X, + 48,Status der Antwort,SG5,STS,,00015,,,,, + 49,Status der Antwort,SG5,STS,9015,00015,E01,,Status der Antwort,, + 50,Status der Antwort,SG5,STS,9013,00015,,,Code des Prüfschritts,,"[16] Der hier angegebene Code des Prüfschritt muss im EBD dem Cluster Zustimmung zugeordnet sein + [17] Der hier angegebene Code des Prüfschritt muss im EBD dem Cluster Ablehnung zugeordnet sein" + 51,Status der Antwort,SG5,STS,1131,00015,E_0218,,EBD Nr. E_0218,, + 52,Status der Berechnungsformel,SG5,STS,,00016,,,,Muss, + 53,Status der Berechnungsformel,SG5,STS,9015,00016,Z23,,Status derBerechnungsformel,X, + 54,Status der Berechnungsformel,SG5,STS,4405,00016,Z33,,Berechnungsformelangefügt,X, + 55,Status der Berechnungsformel,SG5,STS,4405,,Z34,,Berechnungsformel mussbeim Absender angefragtwerden,X, + 56,Status der Berechnungsformel,SG5,STS,4405,,Z40,,Berechnungsformelbesitzt keineRechenoperation,X, + 57,Status der Berechnungsformel,SG5,STS,4405,,Z41,,Berechnungsformel nichterforderlich,X [18],[18] Wenn MP-ID in SG2 NAD+MR (Nachrichtenempfänger) in der Rolle LF + 58,Prüfidentifikator,SG6,,,,,,,Muss, + 59,Prüfidentifikator,SG6,RFF,,00018,,,,Muss, + 60,Prüfidentifikator,SG6,RFF,1153,00018,Z13,,Prüfidentifikator,X, + 61,Prüfidentifikator,SG6,RFF,1154,00018,25001,,Berechnungsformel,X, + 62,Prüfidentifikator,SG6,RFF,1154,,25002,,AblehnungBerechnungsformel,, + 63,Prüfidentifikator,SG6,RFF,1154,,25003,,ZustimmungBerechnungsformel,, + 64,Referenz Vorgangsnummer (aus Berechnungsformel),SG6,,,,,,,, + 65,Referenz Vorgangsnummer (aus Berechnungsformel),SG6,RFF,,00020,,,,, + 66,Referenz Vorgangsnummer (aus Berechnungsformel),SG6,RFF,1153,00020,TN,,Transaktions-Referenznummer,, + 67,Referenz Vorgangsnummer (aus Berechnungsformel),SG6,RFF,1154,00020,,,Vorgangsnummer,, + 68,Lieferrichtung,SG7,,,,,,,Muss, + 69,Lieferrichtung,SG7,CCI,,00021,,,,Muss, + 70,Lieferrichtung,SG7,CCI,7059,00021,Z30,,Lieferrichtung,X, + 71,Lieferrichtung,SG7,CCI,7037,00021,Z06,,Erzeugung,X, + 72,Lieferrichtung,SG7,CCI,7037,,Z07,,Verbrauch,X, + 73,Energiemenge der Marktlokation,SG8,,,,,,,Muss [3],[3] Wenn SG5 STS+Z23+Z33 (Formel angefügt) vorhanden + 74,Energiemenge der Marktlokation,SG8,SEQ,,00022,,,,Muss, + 75,Energiemenge der Marktlokation,SG8,SEQ,1229,00022,Z36,,Energiemenge derMarktlokation,X, + 76,Referenz auf einen Rechenschritt,SG8,RFF,,00023,,,,Muss, + 77,Referenz auf einen Rechenschritt,SG8,RFF,1153,00023,Z23,,Rechenschritt,X, + 78,Referenz auf einen Rechenschritt,SG8,RFF,1154,00023,,,Rechenschrittidentifikator,X [913] [8],"[8] Rechenschrittidentifikato r aus einem SG8 SEQ+Z37 (Bestandteil des Rechenschritts) DE1050 desselben SG5 IDE+24 + [913] Format: Mögliche Werte: 1 bis 99999" + 79,Verwendungszweck der Werte,SG9,,,,,,,Muss, + 80,Verwendungszweck der Werte,SG9,CCI,,00024,,,,Muss, + 81,Verwendungszweck der Werte,SG9,CCI,7059,00024,Z27,,Verwendungszweck derWerte,X, + 82,Verwendungszweck der Werte,SG9,CAV,,00025,,,,Muss [2000],[2000] Segment ist bis zu viermal je SG9 CCI+Z27 anzugeben + 83,Verwendungszweck der Werte,SG9,CAV,7111,00025,Z84,,Netznutzungsabrechnung,X [1P0..1], + 84,Verwendungszweck der Werte,SG9,CAV,7111,,Z85,,Bilanzkreisabrechnung,X [1P0..1], + 85,Verwendungszweck der Werte,SG9,CAV,7111,,Z86,,Mehrmindermengenabrechnung,X [1P0..1], + 86,Verwendungszweck der Werte,SG9,CAV,7111,,Z92,,Übermittlung an dasHKNR,X [1P0..1], + 87,Verwendungszweck der Werte,SG9,CAV,7111,,Z47,,Endkundenabrechnung,X [1P0..1], + 88,Bestandteil des Rechenschritts,SG8,,,,,,,Muss [3],[3] Wenn SG5 STS+Z23+Z33 (Formel angefügt) vorhanden + 89,Bestandteil des Rechenschritts,SG8,SEQ,,00026,,,,Muss, + 90,Bestandteil des Rechenschritts,SG8,SEQ,1229,00026,Z37,,Bestandteil desRechenschritts,X, + 91,Bestandteil des Rechenschritts,SG8,SEQ,1050,00026,,,Rechenschrittidentifikator,X [913],[913] Format: Mögliche Werte: 1 bis 99999 + 92,Referenz auf die ID einer Messlokation,SG8,RFF,,00027,,,,Muss [6],[6] Wenn das SG8 RFF+Z23 (Referenz auf Rechenschritt) in derselben SG8 SEQ+Z37 nicht vorhanden + 93,Referenz auf die ID einer Messlokation,SG8,RFF,1153,00027,Z19,,Messlokation,X, + 94,Referenz auf die ID einer Messlokation,SG8,RFF,1154,00027,,,ID einer Messlokation,X [951][502],"[502] Hinweis: Verwendung der ID der Messlokation + [951] Format: Zählpunktbezeichnung" + 95,Referenz auf einen Rechenschritt,SG8,RFF,,00028,,,,Muss [5],[5] Wenn das SG8 RFF+Z19 (Referenz auf eine Messlokation) in derselben SG8 SEQ+Z37 nicht vorhanden + 96,Referenz auf einen Rechenschritt,SG8,RFF,1153,00028,Z23,,Rechenschritt,X, + 97,Referenz auf einen Rechenschritt,SG8,RFF,1154,00028,,,Rechenschrittidentifikator,X [913] [8] ∧[9],"[8] Rechenschrittidentifikato r aus einem SG8 SEQ+Z37 (Bestandteil des Rechenschritts) DE1050 desselben SG5 IDE+24 + [9] Der hier angegebene Rechenschrittidentifikato r darf nicht identisch mit dem Rechenschrittidentifikato r aus diesem SG8 SEQ+Z37 DE1050 sein + [913] Format: Mögliche Werte: 1 bis 99999" + 98,Mathematischer Operator,SG9,,,,,,,Muss, + 99,Mathematischer Operator,SG9,CCI,,00029,,,,Muss, + 100,Mathematischer Operator,SG9,CCI,7037,00029,Z86,,MathematischerOperator,X, + 101,Operator / Operation,SG9,CAV,,00030,,,,Muss, + 102,Operator / Operation,SG9,CAV,7111,00030,Z69,,Addition,X [11] ⊻ [15], + 103,Operator / Operation,SG9,CAV,7111,,Z70,,Subtraktion,X [11], + 104,Operator / Operation,SG9,CAV,7111,,Z80,,Divisor,X [13],[11] Wenn in SG8 SEQ+Z37 SG9 CCI+++Z86 CAV+Z69/Z70 (Addition / + 105,Energieflussrichtung,SG9,,,,,,,Muss [7],[7] Wenn in derselben SG8 SEQ+Z37 das SG8 RFF+Z19 (Referenz auf eine Messlokation) vorhanden + 106,Energieflussrichtung,SG9,CCI,,00031,,,,Muss, + 107,Energieflussrichtung,SG9,CCI,7037,00031,Z87,,Energieflussrichtung,X, + 108,Energieflussrichtung,SG9,CAV,,00032,,,,Muss, + 109,Energieflussrichtung,SG9,CAV,7111,00032,Z71,,Verbrauch,X, + 110,Energieflussrichtung,SG9,CAV,7111,,Z72,,Erzeugung,X, + 111,Verlustfaktor Trafo,SG9,,,,,,,Soll [10] ∧[7],"[7] Wenn in derselben SG8 SEQ+Z37 das SG8 RFF+Z19 (Referenz auf eine Messlokation) vorhanden + [10] wenn vorhanden" + 112,Verlustfaktor Trafo,SG9,CCI,,00033,,,,Muss, + 113,Verlustfaktor Trafo,SG9,CCI,7037,00033,Z16,,Verlustfaktor Trafo,X, + 114,Verlustfaktor Trafo,SG9,CAV,,00034,,,,Muss, + 115,Verlustfaktor Trafo,SG9,CAV,7111,00034,Z28,,Verlustfaktor,X, + 116,Verlustfaktor Trafo,SG9,CAV,7110,00034,,,Verlustfaktor Trafo,X [912] ∧[914] ∧[915],"[912] Format: Wert kann mit maximal 6 Nachkommastellen angegeben werden + [914] Format: Möglicher Wert: > 0 + [915] Format: Möglicher Wert: ≠ 1" + 117,Verlustfaktor Leitung,SG9,,,,,,,Soll [10] ∧[7],"[7] Wenn in derselben SG8 SEQ+Z37 das SG8 RFF+Z19 (Referenz auf eine Messlokation) vorhanden + [10] wenn vorhanden" + 118,Verlustfaktor Leitung,SG9,CCI,,00035,,,,Muss, + 119,Verlustfaktor Leitung,SG9,CCI,7037,00035,ZB2,,Verlustfaktor Leitung,X, + 120,Verlustfaktor Leitung,SG9,CAV,,00036,,,,Muss, + 121,Verlustfaktor Leitung,SG9,CAV,7111,00036,Z28,,Verlustfaktor,X, + 122,Verlustfaktor Leitung,SG9,CAV,7110,00036,,,Verlustfaktor Leitung,X [912] ∧,[912] Format: Wert kann + 123,Aufteilungsfaktor Energiemenge,SG9,,,,,,,Soll [10] ∧[7],"[7] Wenn in derselben SG8 SEQ+Z37 das SG8 RFF+Z19 (Referenz auf eine Messlokation) vorhanden + [10] wenn vorhanden" + 124,Aufteilungsfaktor Energiemenge,SG9,CCI,,00037,,,,Muss, + 125,Aufteilungsfaktor Energiemenge,SG9,CCI,7037,00037,ZG6,,AufteilungsfaktorEnergiemenge,X, + 126,Aufteilungsfaktor Energiemenge,SG9,CAV,,00038,,,,Muss, + 127,Aufteilungsfaktor Energiemenge,SG9,CAV,7111,00038,ZH6,,AufteilungsfaktorEnergiemenge,X, + 128,Aufteilungsfaktor Energiemenge,SG9,CAV,7110,00038,,,Aufteilungsfaktor Energiemenge,X [914] ∧[969] ∧[912],"[912] Format: Wert kann mit maximal 6 Nachkommastellen angegeben werden + [914] Format: Möglicher Wert: > 0 + [969] Format: Möglicher Wer: ≤ 1" + 129,Nachrichten-Endesegment,,UNT,,00064,,,,Muss, + 130,Nachrichten-Endesegment,,UNT,0074,00064,,,Anzahl der Segmente in einerNachricht,X, + 131,Nachrichten-Endesegment,,UNT,0062,00064,,,Nachrichten-Referenznummer,X, + + ''' +# --- +# name: TestCli.test_kohlrahbi_cli_with_valid_arguments[25003] + ''' + ,Segmentname,Segmentgruppe,Segment,Datenelement,Segment ID,Code,Qualifier,Beschreibung,Bedingungsausdruck,Bedingung + 0,Nachrichten-Kopfsegment,,UNH,,00001,,,,Muss, + 1,Nachrichten-Kopfsegment,,UNH,0062,00001,,,Nachrichten-Referenznummer,X, + 2,Nachrichten-Kopfsegment,,UNH,0065,00001,UTILTS,,Netznutzungszeiten-Nachricht,X, + 3,Nachrichten-Kopfsegment,,UNH,0052,00001,D,,Entwurfs-Version,X, + 4,Nachrichten-Kopfsegment,,UNH,0054,00001,18A,,Ausgabe 2018 - A,X, + 5,Nachrichten-Kopfsegment,,UNH,0051,00001,UN,,UN/CEFACT,X, + 6,Nachrichten-Kopfsegment,,UNH,0057,00001,1.1c,,Versionsnummer derzugrundeliegendenBDEW-Nachrichtenbeschreibung,X, + 7,Beginn der Nachricht,,BGM,,00002,,,,Muss, + 8,Beginn der Nachricht,,BGM,1001,00002,Z36,,Berechnungsformel,X, + 9,Beginn der Nachricht,,BGM,1004,00002,,,Dokumentennummer,X, + 10,Nachrichtendatum,,DTM,,00003,,,,Muss, + 11,Nachrichtendatum,,DTM,2005,00003,137,,Dokumenten-/Nachrichtendatum/-zeit,X, + 12,Nachrichtendatum,,DTM,2380,00003,,,"Datum oder Uhrzeit oderZeitspanne, Wert",X [931][494],"[494] Das hier genannte Datum muss der Zeitpunkt sein, zu dem das Dokument erstellt wurde, oder ein Zeitpunkt, der davor liegt. + [931] Format: ZZZ = +00" + 13,Nachrichtendatum,,DTM,2379,00003,303,,CCYYMMDDHHMMZZZ,X, + 14,MP-ID Absender,SG2,,,,,,,Muss, + 15,MP-ID Absender,SG2,NAD,,00004,,,,Muss, + 16,MP-ID Absender,SG2,NAD,3035,00004,MS,,Dokumenten-/Nachrichtenausstellerbzw. -absender,X, + 17,MP-ID Absender,SG2,NAD,3039,00004,,,MP-ID,X [1],[1] Nur MP-ID aus Sparte Strom + 18,MP-ID Absender,SG2,NAD,3055,00004,9,,GS1,X, + 19,MP-ID Absender,SG2,NAD,3055,,293,,"DE, BDEW(Bundesverband derEnergie- undWasserwirtschaft e.V.)",X, + 20,Ansprechpartner,SG3,,,,,,,Kann,[2] Wenn SG5 STS+Z23+Z34 (Formel muss beim Absender angefragt werden) in einem SG5 IDE vorhanden + 21,Ansprechpartner,SG3,CTA,,00005,,,,Muss, + 22,Ansprechpartner,SG3,CTA,3139,00005,IC,,Informationskontakt,X, + 23,Ansprechpartner,SG3,CTA,3412,00005,,,Name vom Ansprechpartner,X, + 24,Kommunikationsverbindung,SG3,COM,,00006,,,,Muss, + 25,Kommunikationsverbindung,SG3,COM,3148,00006,,,Nummer / Adresse,X, + 26,Kommunikationsverbindung,SG3,COM,3155,00006,EM,,Elektronische Post,X [1P0..1], + 27,Kommunikationsverbindung,SG3,COM,3155,,FX,,Telefax,X [1P0..1], + 28,Kommunikationsverbindung,SG3,COM,3155,,TE,,Telefon,X [1P0..1], + 29,Kommunikationsverbindung,SG3,COM,3155,,AJ,,weiteres Telefon,X [1P0..1], + 30,Kommunikationsverbindung,SG3,COM,3155,,AL,,Handy,X [1P0..1], + 31,MP-ID Empfänger,SG2,,,,,,,Muss, + 32,MP-ID Empfänger,SG2,NAD,,00007,,,,Muss, + 33,MP-ID Empfänger,SG2,NAD,3035,00007,MR,,Nachrichtenempfänger,X, + 34,MP-ID Empfänger,SG2,NAD,3039,00007,,,MP-ID,X [1],[1] Nur MP-ID aus Sparte Strom + 35,MP-ID Empfänger,SG2,NAD,3055,00007,9,,GS1,X, + 36,MP-ID Empfänger,SG2,NAD,3055,,293,,"DE, BDEW(Bundesverband derEnergie- undWasserwirtschaft e.V.)",X, + 37,Vorgang,SG5,,,,,,,Muss, + 38,Vorgang,SG5,IDE,,00008,,,,Muss, + 39,Vorgang,SG5,IDE,7495,00008,24,,Transaktion,X, + 40,Vorgang,SG5,IDE,7402,00008,,,Vorgangsnummer,X, + 41,ID der Marktlokation,SG5,LOC,,00009,,,,, + 42,ID der Marktlokation,SG5,LOC,3227,00009,172,,Meldepunkt,, + 43,ID der Marktlokation,SG5,LOC,3225,00009,,,ID der Marktlokation,,"[501] Hinweis: Verwendung der ID der Marktlokation + [950] Format: Marktlokations-ID" + 44,Gültig ab,SG5,DTM,,00011,,,,, + 45,Gültig ab,SG5,DTM,2005,00011,157,,"Gültigkeit, Beginndatum",, + 46,Gültig ab,SG5,DTM,2380,00011,,,"Datum oder Uhrzeit oderZeitspanne, Wert",,"[500] Hinweis: Zeitpunkt, ab dem die Berechnungsformel anzuwenden ist + [931] Format: ZZZ = +00" + 47,Gültig ab,SG5,DTM,2379,00011,303,,CCYYMMDDHHMMZZZ,, + 48,Status der Antwort,SG5,STS,,00015,,,,Muss, + 49,Status der Antwort,SG5,STS,9015,00015,E01,,Status der Antwort,X, + 50,Status der Antwort,SG5,STS,9013,00015,,,Code des Prüfschritts,X [16],"[16] Der hier angegebene Code des Prüfschritt muss im EBD dem Cluster Zustimmung zugeordnet sein + [17] Der hier angegebene Code des Prüfschritt muss im EBD dem Cluster Ablehnung zugeordnet sein" + 51,Status der Antwort,SG5,STS,1131,00015,E_0218,,EBD Nr. E_0218,X, + 52,Status der Berechnungsformel,SG5,STS,,00016,,,,, + 53,Status der Berechnungsformel,SG5,STS,9015,00016,Z23,,Status derBerechnungsformel,, + 54,Status der Berechnungsformel,SG5,STS,4405,00016,Z33,,Berechnungsformelangefügt,, + 55,Status der Berechnungsformel,SG5,STS,4405,,Z34,,Berechnungsformel mussbeim Absender angefragtwerden,, + 56,Status der Berechnungsformel,SG5,STS,4405,,Z40,,Berechnungsformelbesitzt keineRechenoperation,, + 57,Status der Berechnungsformel,SG5,STS,4405,,Z41,,Berechnungsformel nichterforderlich,,[18] Wenn MP-ID in SG2 NAD+MR (Nachrichtenempfänger) in der Rolle LF + 58,Prüfidentifikator,SG6,,,,,,,Muss, + 59,Prüfidentifikator,SG6,RFF,,00018,,,,Muss, + 60,Prüfidentifikator,SG6,RFF,1153,00018,Z13,,Prüfidentifikator,X, + 61,Prüfidentifikator,SG6,RFF,1154,00018,25001,,Berechnungsformel,, + 62,Prüfidentifikator,SG6,RFF,1154,,25002,,AblehnungBerechnungsformel,, + 63,Prüfidentifikator,SG6,RFF,1154,,25003,,ZustimmungBerechnungsformel,X, + 64,Referenz Vorgangsnummer (aus Berechnungsformel),SG6,,,,,,,Muss, + 65,Referenz Vorgangsnummer (aus Berechnungsformel),SG6,RFF,,00020,,,,Muss, + 66,Referenz Vorgangsnummer (aus Berechnungsformel),SG6,RFF,1153,00020,TN,,Transaktions-Referenznummer,X, + 67,Referenz Vorgangsnummer (aus Berechnungsformel),SG6,RFF,1154,00020,,,Vorgangsnummer,X, + 68,Lieferrichtung,SG7,,,,,,,, + 69,Lieferrichtung,SG7,CCI,,00021,,,,, + 70,Lieferrichtung,SG7,CCI,7059,00021,Z30,,Lieferrichtung,, + 71,Lieferrichtung,SG7,CCI,7037,00021,Z06,,Erzeugung,, + 72,Lieferrichtung,SG7,CCI,7037,,Z07,,Verbrauch,, + 73,Energiemenge der Marktlokation,SG8,,,,,,,,[3] Wenn SG5 STS+Z23+Z33 (Formel angefügt) vorhanden + 74,Energiemenge der Marktlokation,SG8,SEQ,,00022,,,,, + 75,Energiemenge der Marktlokation,SG8,SEQ,1229,00022,Z36,,Energiemenge derMarktlokation,, + 76,Referenz auf einen Rechenschritt,SG8,RFF,,00023,,,,, + 77,Referenz auf einen Rechenschritt,SG8,RFF,1153,00023,Z23,,Rechenschritt,, + 78,Referenz auf einen Rechenschritt,SG8,RFF,1154,00023,,,Rechenschrittidentifikator,,"[8] Rechenschrittidentifikato r aus einem SG8 SEQ+Z37 (Bestandteil des Rechenschritts) DE1050 desselben SG5 IDE+24 + [913] Format: Mögliche Werte: 1 bis 99999" + 79,Verwendungszweck der Werte,SG9,,,,,,,, + 80,Verwendungszweck der Werte,SG9,CCI,,00024,,,,, + 81,Verwendungszweck der Werte,SG9,CCI,7059,00024,Z27,,Verwendungszweck derWerte,, + 82,Verwendungszweck der Werte,SG9,CAV,,00025,,,,,[2000] Segment ist bis zu viermal je SG9 CCI+Z27 anzugeben + 83,Verwendungszweck der Werte,SG9,CAV,7111,00025,Z84,,Netznutzungsabrechnung,, + 84,Verwendungszweck der Werte,SG9,CAV,7111,,Z85,,Bilanzkreisabrechnung,, + 85,Verwendungszweck der Werte,SG9,CAV,7111,,Z86,,Mehrmindermengenabrechnung,, + 86,Verwendungszweck der Werte,SG9,CAV,7111,,Z92,,Übermittlung an dasHKNR,, + 87,Verwendungszweck der Werte,SG9,CAV,7111,,Z47,,Endkundenabrechnung,, + 88,Bestandteil des Rechenschritts,SG8,,,,,,,,[3] Wenn SG5 STS+Z23+Z33 (Formel angefügt) vorhanden + 89,Bestandteil des Rechenschritts,SG8,SEQ,,00026,,,,, + 90,Bestandteil des Rechenschritts,SG8,SEQ,1229,00026,Z37,,Bestandteil desRechenschritts,, + 91,Bestandteil des Rechenschritts,SG8,SEQ,1050,00026,,,Rechenschrittidentifikator,,[913] Format: Mögliche Werte: 1 bis 99999 + 92,Referenz auf die ID einer Messlokation,SG8,RFF,,00027,,,,,[6] Wenn das SG8 RFF+Z23 (Referenz auf Rechenschritt) in derselben SG8 SEQ+Z37 nicht vorhanden + 93,Referenz auf die ID einer Messlokation,SG8,RFF,1153,00027,Z19,,Messlokation,, + 94,Referenz auf die ID einer Messlokation,SG8,RFF,1154,00027,,,ID einer Messlokation,,"[502] Hinweis: Verwendung der ID der Messlokation + [951] Format: Zählpunktbezeichnung" + 95,Referenz auf einen Rechenschritt,SG8,RFF,,00028,,,,,[5] Wenn das SG8 RFF+Z19 (Referenz auf eine Messlokation) in derselben SG8 SEQ+Z37 nicht vorhanden + 96,Referenz auf einen Rechenschritt,SG8,RFF,1153,00028,Z23,,Rechenschritt,, + 97,Referenz auf einen Rechenschritt,SG8,RFF,1154,00028,,,Rechenschrittidentifikator,,"[8] Rechenschrittidentifikato r aus einem SG8 SEQ+Z37 (Bestandteil des Rechenschritts) DE1050 desselben SG5 IDE+24 + [9] Der hier angegebene Rechenschrittidentifikato r darf nicht identisch mit dem Rechenschrittidentifikato r aus diesem SG8 SEQ+Z37 DE1050 sein + [913] Format: Mögliche Werte: 1 bis 99999" + 98,Mathematischer Operator,SG9,,,,,,,, + 99,Mathematischer Operator,SG9,CCI,,00029,,,,, + 100,Mathematischer Operator,SG9,CCI,7037,00029,Z86,,MathematischerOperator,, + 101,Operator / Operation,SG9,CAV,,00030,,,,, + 102,Operator / Operation,SG9,CAV,7111,00030,Z69,,Addition,, + 103,Operator / Operation,SG9,CAV,7111,,Z70,,Subtraktion,, + 104,Operator / Operation,SG9,CAV,7111,,Z80,,Divisor,,[11] Wenn in SG8 SEQ+Z37 SG9 CCI+++Z86 CAV+Z69/Z70 (Addition / + 105,Energieflussrichtung,SG9,,,,,,,,[7] Wenn in derselben SG8 SEQ+Z37 das SG8 RFF+Z19 (Referenz auf eine Messlokation) vorhanden + 106,Energieflussrichtung,SG9,CCI,,00031,,,,, + 107,Energieflussrichtung,SG9,CCI,7037,00031,Z87,,Energieflussrichtung,, + 108,Energieflussrichtung,SG9,CAV,,00032,,,,, + 109,Energieflussrichtung,SG9,CAV,7111,00032,Z71,,Verbrauch,, + 110,Energieflussrichtung,SG9,CAV,7111,,Z72,,Erzeugung,, + 111,Verlustfaktor Trafo,SG9,,,,,,,,"[7] Wenn in derselben SG8 SEQ+Z37 das SG8 RFF+Z19 (Referenz auf eine Messlokation) vorhanden + [10] wenn vorhanden" + 112,Verlustfaktor Trafo,SG9,CCI,,00033,,,,, + 113,Verlustfaktor Trafo,SG9,CCI,7037,00033,Z16,,Verlustfaktor Trafo,, + 114,Verlustfaktor Trafo,SG9,CAV,,00034,,,,, + 115,Verlustfaktor Trafo,SG9,CAV,7111,00034,Z28,,Verlustfaktor,, + 116,Verlustfaktor Trafo,SG9,CAV,7110,00034,,,Verlustfaktor Trafo,,"[912] Format: Wert kann mit maximal 6 Nachkommastellen angegeben werden + [914] Format: Möglicher Wert: > 0 + [915] Format: Möglicher Wert: ≠ 1" + 117,Verlustfaktor Leitung,SG9,,,,,,,,"[7] Wenn in derselben SG8 SEQ+Z37 das SG8 RFF+Z19 (Referenz auf eine Messlokation) vorhanden + [10] wenn vorhanden" + 118,Verlustfaktor Leitung,SG9,CCI,,00035,,,,, + 119,Verlustfaktor Leitung,SG9,CCI,7037,00035,ZB2,,Verlustfaktor Leitung,, + 120,Verlustfaktor Leitung,SG9,CAV,,00036,,,,, + 121,Verlustfaktor Leitung,SG9,CAV,7111,00036,Z28,,Verlustfaktor,, + 122,Verlustfaktor Leitung,SG9,CAV,7110,00036,,,Verlustfaktor Leitung,,[912] Format: Wert kann + 123,Aufteilungsfaktor Energiemenge,SG9,,,,,,,,"[7] Wenn in derselben SG8 SEQ+Z37 das SG8 RFF+Z19 (Referenz auf eine Messlokation) vorhanden + [10] wenn vorhanden" + 124,Aufteilungsfaktor Energiemenge,SG9,CCI,,00037,,,,, + 125,Aufteilungsfaktor Energiemenge,SG9,CCI,7037,00037,ZG6,,AufteilungsfaktorEnergiemenge,, + 126,Aufteilungsfaktor Energiemenge,SG9,CAV,,00038,,,,, + 127,Aufteilungsfaktor Energiemenge,SG9,CAV,7111,00038,ZH6,,AufteilungsfaktorEnergiemenge,, + 128,Aufteilungsfaktor Energiemenge,SG9,CAV,7110,00038,,,Aufteilungsfaktor Energiemenge,,"[912] Format: Wert kann mit maximal 6 Nachkommastellen angegeben werden + [914] Format: Möglicher Wert: > 0 + [969] Format: Möglicher Wer: ≤ 1" + 129,Nachrichten-Endesegment,,UNT,,00064,,,,Muss, + 130,Nachrichten-Endesegment,,UNT,0074,00064,,,Anzahl der Segmente in einerNachricht,X, + 131,Nachrichten-Endesegment,,UNT,0062,00064,,,Nachrichten-Referenznummer,X, + + ''' +# --- +# name: TestCli.test_kohlrahbi_cli_with_valid_arguments[25004] + ''' + ,Segmentname,Segmentgruppe,Segment,Datenelement,Segment ID,Code,Qualifier,Beschreibung,Bedingungsausdruck,Bedingung + 0,Nachrichten-Kopfsegment,,UNH,,00001,,,,Muss, + 1,Nachrichten-Kopfsegment,,UNH,0062,00001,,,Nachrichten-Referenznummer,X, + 2,Nachrichten-Kopfsegment,,UNH,0065,00001,UTILTS,,Netznutzungszeiten-Nachricht,X, + 3,Nachrichten-Kopfsegment,,UNH,0052,00001,D,,Entwurfs-Version,X, + 4,Nachrichten-Kopfsegment,,UNH,0054,00001,18A,,Ausgabe 2018 - A,X, + 5,Nachrichten-Kopfsegment,,UNH,0051,00001,UN,,UN/CEFACT,X, + 6,Nachrichten-Kopfsegment,,UNH,0057,00001,1.1c,,Versionsnummer derzugrundeliegendenBDEW-Nachrichtenbeschreibung,X, + 7,Beginn der Nachricht,,BGM,,00002,,,,Muss, + 8,Beginn der Nachricht,,BGM,1001,00002,Z60,,ÜbersichtZählzeitdefinitionen,X, + 9,Beginn der Nachricht,,BGM,1001,,Z78,,ÜbersichtSchaltzeitdefinitionen,, + 10,Beginn der Nachricht,,BGM,1001,,Z79,,ÜbersichtLeistungskurvendefinitionen,, + 11,Beginn der Nachricht,,BGM,1004,00002,,,Dokumentennummer,X, + 12,Nachrichtendatum,,DTM,,00003,,,,Muss, + 13,Nachrichtendatum,,DTM,2005,00003,137,,Dokumenten-/Nachrichtendatum/-zeit,X, + 14,Nachrichtendatum,,DTM,2380,00003,,,"Datum oder Uhrzeit oderZeitspanne, Wert",X [931][494],"[494] Das hier genannte Datum muss der Zeitpunkt sein, zu dem das Dokument erstellt wurde, oder ein Zeitpunkt, der davor liegt. + [931] Format: ZZZ = +00" + 15,Nachrichtendatum,,DTM,2379,00003,303,,CCYYMMDDHHMMZZZ,X, + 16,MP-ID Absender,SG2,,,,,,,Muss, + 17,MP-ID Absender,SG2,NAD,,00004,,,,Muss, + 18,MP-ID Absender,SG2,NAD,3035,00004,MS,,Dokumenten-/Nachrichtenausstellerbzw. -absender,X, + 19,MP-ID Absender,SG2,NAD,3039,00004,,,MP-ID,X [1],[1] Nur MP-ID aus Sparte Strom + 20,MP-ID Absender,SG2,NAD,3055,00004,9,,GS1,X, + 21,MP-ID Absender,SG2,NAD,3055,,293,,"DE, BDEW(Bundesverband der",X, + 22,Ansprechpartner,SG3,,,,,,,Kann, + 23,Ansprechpartner,SG3,CTA,,00005,,,,Muss, + 24,Ansprechpartner,SG3,CTA,3139,00005,IC,,Informationskontakt,X, + 25,Ansprechpartner,SG3,CTA,3412,00005,,,Name vom Ansprechpartner,X, + 26,Kommunikationsverbindung,SG3,COM,,00006,,,,Muss, + 27,Kommunikationsverbindung,SG3,COM,3148,00006,,,Nummer / Adresse,X, + 28,Kommunikationsverbindung,SG3,COM,3155,00006,EM,,Elektronische Post,X [1P0..1], + 29,Kommunikationsverbindung,SG3,COM,3155,,FX,,Telefax,X [1P0..1], + 30,Kommunikationsverbindung,SG3,COM,3155,,TE,,Telefon,X [1P0..1], + 31,Kommunikationsverbindung,SG3,COM,3155,,AJ,,weiteres Telefon,X [1P0..1], + 32,Kommunikationsverbindung,SG3,COM,3155,,AL,,Handy,X [1P0..1], + 33,MP-ID Empfänger,SG2,,,,,,,Muss, + 34,MP-ID Empfänger,SG2,NAD,,00007,,,,Muss, + 35,MP-ID Empfänger,SG2,NAD,3035,00007,MR,,Nachrichtenempfänger,X, + 36,MP-ID Empfänger,SG2,NAD,3039,00007,,,MP-ID,X [1],[1] Nur MP-ID aus Sparte Strom + 37,MP-ID Empfänger,SG2,NAD,3055,00007,9,,GS1,X, + 38,MP-ID Empfänger,SG2,NAD,3055,,293,,"DE, BDEW(Bundesverband derEnergie- undWasserwirtschaft e.V.)",X, + 39,Vorgang,SG5,,,,,,,Muss [2001],[2001] Segment bzw. Segmentgruppe ist genau einmal anzugeben + 40,Vorgang,SG5,IDE,,00008,,,,Muss, + 41,Vorgang,SG5,IDE,7495,00008,24,,Transaktion,X, + 42,Vorgang,SG5,IDE,7402,00008,,,Vorgangsnummer,X, + 43,Gültig ab,SG5,DTM,,00011,,,,Muss, + 44,Gültig ab,SG5,DTM,2005,00011,157,,"Gültigkeit, Beginndatum",X, + 45,Gültig ab,SG5,DTM,2380,00011,,,"Datum oder Uhrzeit oderZeitspanne, Wert",X [931][506] ∧[UB1],"[506] Hinweis: Zeitpunkt, ab dem die Übersicht der Zählzeitdefinitionen gültig ist + [508] Hinweis: Zeitpunkt, ab dem die Übersicht der Schaltzeitdefinitionen gültig ist " + 46,Gültig ab,SG5,DTM,2379,00011,303,,CCYYMMDDHHMMZZZ,X, + 47,Versionsangabe,SG5,DTM,,00014,,,,Muss, + 48,Versionsangabe,SG5,DTM,2005,00014,293,,Fertigstellungsdatum/-zeit,X, + 49,Versionsangabe,SG5,DTM,2380,00014,,,"Datum oder Uhrzeit oderZeitspanne, Wert",X [931],[931] Format: ZZZ = +00 + 50,Versionsangabe,SG5,DTM,2379,00014,304,,CCYYMMDDHHMMSSZZZ,X, + 51,Status der Nutzung von Definitionen,SG5,STS,,00017,,,,Muss, + 52,Status der Nutzung von Definitionen,SG5,STS,9015,00017,Z36,,Nutzung vonDefinitionen,X, + 53,Status der Nutzung von Definitionen,SG5,STS,4405,00017,Z45,,Definitionen werdenverwendet,X, + 54,Status der Nutzung von Definitionen,SG5,STS,4405,,Z46,,Definitionen werdennicht verwendet,X, + 55,Prüfidentifikator,SG6,,,,,,,Muss, + 56,Prüfidentifikator,SG6,RFF,,00018,,,,Muss, + 57,Prüfidentifikator,SG6,RFF,1153,00018,Z13,,Prüfidentifikator,X, + 58,Prüfidentifikator,SG6,RFF,1154,00018,25004,,ÜbersichtZählzeitdefinitionen,X, + 59,Prüfidentifikator,SG6,RFF,1154,,25006,,ÜbersichtSchaltzeitdefinitionen,, + 60,Prüfidentifikator,SG6,RFF,1154,,25007,,ÜbersichtLeistungskurvendefinitionen,, + 61,Referenz auf Reklamation,SG6,,,,,,,Soll [26],[26] sofern per ORDERS reklamiert + 62,Referenz auf Reklamation,SG6,RFF,,00019,,,,Muss, + 63,Referenz auf Reklamation,SG6,RFF,1153,00019,AGI,,Beantragungsnummer,X, + 64,Referenz auf Reklamation,SG6,RFF,1154,00019,,,"Referenz, Identifikation",X [504],[504] Hinweis: Wert aus BGM+Z55 DE1004 der ORDERS mit der die Reklamation einer Definition erfolgt ist + 65,Zählzeitdefinition,SG8,,,,,,,Muss [24],[24] Wenn SG5 + 66,Zählzeitdefinition,SG8,SEQ,,00039,,,,Muss, + 67,Zählzeitdefinition,SG8,SEQ,1229,00039,Z42,,Zählzeitdefinition,X, + 68,Code der Zählzeitdefinition,SG9,,,,,,,Muss, + 69,Code der Zählzeitdefinition,SG9,CCI,,00042,,,,Muss, + 70,Code der Zählzeitdefinition,SG9,CCI,7059,00042,Z39,,Code derZählzeitdefinition,X, + 71,Code der Zählzeitdefinition,SG9,CCI,7037,00042,,,Code der Zählzeitdefinition,X [44],[44] Der in diesem Datenlement angegebene Code der Zählzeitdefinition muss innerhalb eines Vorgangs (IDE) eindeutig sein. + 72,Häufigkeit der Übermittlung,SG9,CAV,,00043,,,,Muss, + 73,Häufigkeit der Übermittlung,SG9,CAV,7111,00043,ZE0,,Häufigkeit derÜbermittlung,X, + 74,Häufigkeit der Übermittlung,SG9,CAV,7110,00043,Z33,,einmalig zuübermittelndeausgerollte Definition,X, + 75,Häufigkeit der Übermittlung,SG9,CAV,7110,,Z34,,jährlich zu übermittelndeausgerollte Definition,X, + 76,Übermittelbarkeit der ausgerollten Zählzeitdefinition,SG9,CAV,,00044,,,,Muss, + 77,Übermittelbarkeit der ausgerollten Zählzeitdefinition,SG9,CAV,7111,00044,ZD5,,Übermittelbarkeit derausgerollten Definition,X, + 78,Übermittelbarkeit der ausgerollten Zählzeitdefinition,SG9,CAV,7110,00044,Z23,,elektronischübermittelbar,X, + 79,Übermittelbarkeit der ausgerollten Zählzeitdefinition,SG9,CAV,7110,,Z24,,elektronisch nichtübermittelbar,X, + 80,Ermittlung des Leistungsmaximums bei atypischer Netznutzung,SG9,CAV,,00045,,,,Muss [22],[22] Wenn MP-ID in SG2 NAD+MS (Nachrichtenabsender) in der Rolle NB + 81,Ermittlung des Leistungsmaximums bei atypischer Netznutzung,SG9,CAV,7111,00045,ZD4,,Ermittlung desLeistungsmaximums beiatypischer Netznutzung,X, + 82,Ermittlung des Leistungsmaximums bei atypischer Netznutzung,SG9,CAV,7110,00045,Z25,,Verwendung desHochlastzeitfensters,X, + 83,Ermittlung des Leistungsmaximums bei atypischer Netznutzung,SG9,CAV,7110,,Z26,,keine Verwendung desHochlastzeitfensters,X, + 84,Bestellbarkeit der Zählzeitdefinition,SG9,CAV,,00046,,,,Muss [22] ∧[25],"[22] Wenn MP-ID in SG2 NAD+MS (Nachrichtenabsender) in der Rolle NB + [25] Wenn MP-ID in SG2 NAD+MR (Nachrichtenempfänger) in der Rolle LF" + 85,Bestellbarkeit der Zählzeitdefinition,SG9,CAV,7111,00046,ZD7,,Bestellbarkeit derZählzeitdefinition,X, + 86,Bestellbarkeit der Zählzeitdefinition,SG9,CAV,7110,00046,Z27,,Zählzeitdefinition istbestellbar,X, + 87,Bestellbarkeit der Zählzeitdefinition,SG9,CAV,7110,,Z28,,Zählzeitdefinition istnicht bestellbar,X, + 88,Zählzeitdefinitionstyp,SG9,CAV,,00047,,,,Muss [22] ∧[27],"[22] Wenn MP-ID in SG2 NAD+MS (Nachrichtenabsender) in der Rolle NB + [27] Wenn in SG9 CAV+ZD4+Z26 (keine Verwendung des Hochlastzeitfensters) vorhanden" + 89,Zählzeitdefinitionstyp,SG9,CAV,7111,00047,ZD3,,Zählzeitdefinitionstyp,X, + 90,Zählzeitdefinitionstyp,SG9,CAV,7110,00047,Z29,,Wärmepumpe,X, + 91,Zählzeitdefinitionstyp,SG9,CAV,7110,,Z30,,Nachtspeicherheizung,X, + 92,Zählzeitdefinitionstyp,SG9,CAV,7110,,Z31,,Schwachlastzeitfenster,X, + 93,Zählzeitdefinitionstyp,SG9,CAV,7110,,Z32,,sonstigerZählzeitdefinitionstyp,X, + 94,Zählzeitdefinitionstyp,SG9,CAV,7110,,Z35,,Hochlastzeitfenster,X, + 95,Zählzeitdefinitionstyp,SG9,CAV,7110,00047,,,BeschreibungZählzeitdefinitionstyp,X [21],[21] Wenn in dieser CAV+ZD3 der Wert im DE7110 mit Z32 (sonstiger Zählzeitdefinitionstyp) vorhanden ist + 96,Register der Zählzeitdefinition,SG8,,,,,,,Muss [41] ∧[2002],"[41] Wenn SG8 SEQ+Z42 (Zählzeitdefinition) vorhanden + [2002] Für jeden Code der Zählzeit aus SG8 SEQ+Z42 (Zählzeitdefinition) SG9 CCI+Z39 (Code der Zählzeitdefinition) sind mindestens zwei Register anzugeben, bei denen in dieser SG8 das SG8 RFF+Z27 mit diesem Code gefüllt ist" + 97,Register der Zählzeitdefinition,SG8,SEQ,,00048,,,,Muss, + 98,Register der Zählzeitdefinition,SG8,SEQ,1229,00048,Z41,,Register derZählzeitdefinition,X, + 99,Referenz auf eine Zählzeitdefinition,SG8,RFF,,00049,,,,Muss, + 100,Referenz auf eine Zählzeitdefinition,SG8,RFF,1153,00049,Z27,,Code derZählzeitdefinition,X, + 101,Referenz auf eine Zählzeitdefinition,SG8,RFF,1154,00049,,,Code der Zählzeitdefinition,X, + 102,Code des Zählzeitregister,SG9,,,,,,,Muss, + 103,Code des Zählzeitregister,SG9,CCI,,00050,,,,Muss, + 104,Code des Zählzeitregister,SG9,CCI,7059,00050,Z38,,Code desZählzeitregisters,X, + 105,Code des Zählzeitregister,SG9,CCI,7037,00050,,,Code des Zählzeitregisters,X, + 106,Schwachlastfähigkeit,SG9,,,,,,,Muss [22],[22] Wenn MP-ID in SG2 NAD+MS (Nachrichtenabsender) in der Rolle NB + 107,Schwachlastfähigkeit,SG9,CCI,,00051,,,,Muss, + 108,Schwachlastfähigkeit,SG9,CCI,7059,00051,Z10,,Schwachlastfähigkeit,X, + 109,Schwachlastfähigkeit,SG9,CCI,7037,00051,Z59,,Nicht-Schwachlast fähig,X, + 110,Schwachlastfähigkeit,SG9,CCI,7037,,Z60,,Schwachlast fähig,X, + 111,Schaltzeitdefinition,SG8,,,,,,,,[24] Wenn SG5 STS+Z36+Z45 (Definitionen werden verwendet) vorhanden + 112,Schaltzeitdefinition,SG8,SEQ,,00052,,,,, + 113,Schaltzeitdefinition,SG8,SEQ,1229,00052,Z69,,Schaltzeitdefinition,, + 114,Code der Schaltzeitdefinition,SG9,,,,,,,, + 115,Code der Schaltzeitdefinition,SG9,CCI,,00054,,,,, + 116,Code der Schaltzeitdefinition,SG9,CCI,7059,00054,Z52,,Code derSchaltzeitdefinition,, + 117,Code der Schaltzeitdefinition,SG9,CCI,7037,00054,,,Code der Schaltzeitdefinition,,[42] Der in diesem Datenlement angegebene Code der Schaltzeitdefinition muss innerhalb eines Vorgangs (IDE) eindeutig sein. + 118,Häufigkeit der Übermittlung,SG9,CAV,,00055,,,,, + 119,Häufigkeit der Übermittlung,SG9,CAV,7111,00055,ZE0,,Häufigkeit derÜbermittlung,, + 120,Häufigkeit der Übermittlung,SG9,CAV,7110,00055,Z33,,einmalig zuübermittelndeausgerollte Definition,, + 121,Häufigkeit der Übermittlung,SG9,CAV,7110,,Z34,,jährlich zu übermittelndeausgerollte Definition,, + 122,Übermittelbarkeit der ausgerollten Schaltzeitdefinition,SG9,CAV,,00056,,,,, + 123,Übermittelbarkeit der ausgerollten Schaltzeitdefinition,SG9,CAV,7111,00056,ZD5,,Übermittelbarkeit derausgerollten Definition,, + 124,Übermittelbarkeit der ausgerollten Schaltzeitdefinition,SG9,CAV,7110,00056,Z23,,elektronischübermittelbar,, + 125,Übermittelbarkeit der ausgerollten Schaltzeitdefinition,SG9,CAV,7110,,Z24,,elektronisch nichtübermittelbar,, + 126,Leistungskurvendefinition,SG8,,,,,,,,[24] Wenn SG5 STS+Z36+Z45 (Definitionen werden verwendet) vorhanden + 127,Leistungskurvendefinition,SG8,SEQ,,00058,,,,, + 128,Leistungskurvendefinition,SG8,SEQ,1229,00058,Z70,,Leistungskurvendefinition,, + 129,Code der Leistungskurvendefinition,SG9,,,,,,,, + 130,Code der Leistungskurvendefinition,SG9,CCI,,00060,,,,, + 131,Code der Leistungskurvendefinition,SG9,CCI,7059,00060,Z53,,Code derLeistungskurvendefinition,, + 132,Code der Leistungskurvendefinition,SG9,CCI,7037,00060,,,Code der,,[43] Der in diesem + 133,Häufigkeit der Übermittlung,SG9,CAV,,00061,,,,, + 134,Häufigkeit der Übermittlung,SG9,CAV,7111,00061,ZE0,,Häufigkeit derÜbermittlung,, + 135,Häufigkeit der Übermittlung,SG9,CAV,7110,00061,Z33,,einmalig zuübermittelndeausgerollte Definition,, + 136,Häufigkeit der Übermittlung,SG9,CAV,7110,,Z34,,jährlich zu übermittelndeausgerollte Definition,, + 137,Übermittelbarkeit der ausgerollten Leistungskurvendefinition,SG9,CAV,,00062,,,,, + 138,Übermittelbarkeit der ausgerollten Leistungskurvendefinition,SG9,CAV,7111,00062,ZD5,,Übermittelbarkeit derausgerollten Definition,, + 139,Übermittelbarkeit der ausgerollten Leistungskurvendefinition,SG9,CAV,7110,00062,Z23,,elektronischübermittelbar,, + 140,Übermittelbarkeit der ausgerollten Leistungskurvendefinition,SG9,CAV,7110,,Z24,,elektronisch nichtübermittelbar,, + 141,Nachrichten-Endesegment,,UNT,,00064,,,,Muss, + 142,Nachrichten-Endesegment,,UNT,0074,00064,,,Anzahl der Segmente in einerNachricht,X, + 143,Nachrichten-Endesegment,,UNT,0062,00064,,,Nachrichten-Referenznummer,X, + + ''' +# --- +# name: TestCli.test_kohlrahbi_cli_with_valid_arguments[25006] + ''' + ,Segmentname,Segmentgruppe,Segment,Datenelement,Segment ID,Code,Qualifier,Beschreibung,Bedingungsausdruck,Bedingung + 0,Nachrichten-Kopfsegment,,UNH,,00001,,,,Muss, + 1,Nachrichten-Kopfsegment,,UNH,0062,00001,,,Nachrichten-Referenznummer,X, + 2,Nachrichten-Kopfsegment,,UNH,0065,00001,UTILTS,,Netznutzungszeiten-Nachricht,X, + 3,Nachrichten-Kopfsegment,,UNH,0052,00001,D,,Entwurfs-Version,X, + 4,Nachrichten-Kopfsegment,,UNH,0054,00001,18A,,Ausgabe 2018 - A,X, + 5,Nachrichten-Kopfsegment,,UNH,0051,00001,UN,,UN/CEFACT,X, + 6,Nachrichten-Kopfsegment,,UNH,0057,00001,1.1c,,Versionsnummer derzugrundeliegendenBDEW-Nachrichtenbeschreibung,X, + 7,Beginn der Nachricht,,BGM,,00002,,,,Muss, + 8,Beginn der Nachricht,,BGM,1001,00002,Z60,,ÜbersichtZählzeitdefinitionen,, + 9,Beginn der Nachricht,,BGM,1001,,Z78,,ÜbersichtSchaltzeitdefinitionen,X, + 10,Beginn der Nachricht,,BGM,1001,,Z79,,ÜbersichtLeistungskurvendefinitionen,, + 11,Beginn der Nachricht,,BGM,1004,00002,,,Dokumentennummer,X, + 12,Nachrichtendatum,,DTM,,00003,,,,Muss, + 13,Nachrichtendatum,,DTM,2005,00003,137,,Dokumenten-/Nachrichtendatum/-zeit,X, + 14,Nachrichtendatum,,DTM,2380,00003,,,"Datum oder Uhrzeit oderZeitspanne, Wert",X [931][494],"[494] Das hier genannte Datum muss der Zeitpunkt sein, zu dem das Dokument erstellt wurde, oder ein Zeitpunkt, der davor liegt. + [931] Format: ZZZ = +00" + 15,Nachrichtendatum,,DTM,2379,00003,303,,CCYYMMDDHHMMZZZ,X, + 16,MP-ID Absender,SG2,,,,,,,Muss, + 17,MP-ID Absender,SG2,NAD,,00004,,,,Muss, + 18,MP-ID Absender,SG2,NAD,3035,00004,MS,,Dokumenten-/Nachrichtenausstellerbzw. -absender,X, + 19,MP-ID Absender,SG2,NAD,3039,00004,,,MP-ID,X [1],[1] Nur MP-ID aus Sparte Strom + 20,MP-ID Absender,SG2,NAD,3055,00004,9,,GS1,X, + 21,MP-ID Absender,SG2,NAD,3055,,293,,"DE, BDEW(Bundesverband der",X, + 22,Ansprechpartner,SG3,,,,,,,Kann, + 23,Ansprechpartner,SG3,CTA,,00005,,,,Muss, + 24,Ansprechpartner,SG3,CTA,3139,00005,IC,,Informationskontakt,X, + 25,Ansprechpartner,SG3,CTA,3412,00005,,,Name vom Ansprechpartner,X, + 26,Kommunikationsverbindung,SG3,COM,,00006,,,,Muss, + 27,Kommunikationsverbindung,SG3,COM,3148,00006,,,Nummer / Adresse,X, + 28,Kommunikationsverbindung,SG3,COM,3155,00006,EM,,Elektronische Post,X [1P0..1], + 29,Kommunikationsverbindung,SG3,COM,3155,,FX,,Telefax,X [1P0..1], + 30,Kommunikationsverbindung,SG3,COM,3155,,TE,,Telefon,X [1P0..1], + 31,Kommunikationsverbindung,SG3,COM,3155,,AJ,,weiteres Telefon,X [1P0..1], + 32,Kommunikationsverbindung,SG3,COM,3155,,AL,,Handy,X [1P0..1], + 33,MP-ID Empfänger,SG2,,,,,,,Muss, + 34,MP-ID Empfänger,SG2,NAD,,00007,,,,Muss, + 35,MP-ID Empfänger,SG2,NAD,3035,00007,MR,,Nachrichtenempfänger,X, + 36,MP-ID Empfänger,SG2,NAD,3039,00007,,,MP-ID,X [1],[1] Nur MP-ID aus Sparte Strom + 37,MP-ID Empfänger,SG2,NAD,3055,00007,9,,GS1,X, + 38,MP-ID Empfänger,SG2,NAD,3055,,293,,"DE, BDEW(Bundesverband derEnergie- undWasserwirtschaft e.V.)",X, + 39,Vorgang,SG5,,,,,,,Muss [2001],[2001] Segment bzw. Segmentgruppe ist genau einmal anzugeben + 40,Vorgang,SG5,IDE,,00008,,,,Muss, + 41,Vorgang,SG5,IDE,7495,00008,24,,Transaktion,X, + 42,Vorgang,SG5,IDE,7402,00008,,,Vorgangsnummer,X, + 43,Gültig ab,SG5,DTM,,00011,,,,Muss, + 44,Gültig ab,SG5,DTM,2005,00011,157,,"Gültigkeit, Beginndatum",X, + 45,Gültig ab,SG5,DTM,2380,00011,,,"Datum oder Uhrzeit oderZeitspanne, Wert",X [931][508] ∧[UB1],"[506] Hinweis: Zeitpunkt, ab dem die Übersicht der Zählzeitdefinitionen gültig ist + [508] Hinweis: Zeitpunkt, ab dem die Übersicht der Schaltzeitdefinitionen gültig ist " + 46,Gültig ab,SG5,DTM,2379,00011,303,,CCYYMMDDHHMMZZZ,X, + 47,Versionsangabe,SG5,DTM,,00014,,,,Muss, + 48,Versionsangabe,SG5,DTM,2005,00014,293,,Fertigstellungsdatum/-zeit,X, + 49,Versionsangabe,SG5,DTM,2380,00014,,,"Datum oder Uhrzeit oderZeitspanne, Wert",X [931],[931] Format: ZZZ = +00 + 50,Versionsangabe,SG5,DTM,2379,00014,304,,CCYYMMDDHHMMSSZZZ,X, + 51,Status der Nutzung von Definitionen,SG5,STS,,00017,,,,Muss, + 52,Status der Nutzung von Definitionen,SG5,STS,9015,00017,Z36,,Nutzung vonDefinitionen,X, + 53,Status der Nutzung von Definitionen,SG5,STS,4405,00017,Z45,,Definitionen werdenverwendet,X, + 54,Status der Nutzung von Definitionen,SG5,STS,4405,,Z46,,Definitionen werdennicht verwendet,X, + 55,Prüfidentifikator,SG6,,,,,,,Muss, + 56,Prüfidentifikator,SG6,RFF,,00018,,,,Muss, + 57,Prüfidentifikator,SG6,RFF,1153,00018,Z13,,Prüfidentifikator,X, + 58,Prüfidentifikator,SG6,RFF,1154,00018,25004,,ÜbersichtZählzeitdefinitionen,, + 59,Prüfidentifikator,SG6,RFF,1154,,25006,,ÜbersichtSchaltzeitdefinitionen,X, + 60,Prüfidentifikator,SG6,RFF,1154,,25007,,ÜbersichtLeistungskurvendefinitionen,, + 61,Referenz auf Reklamation,SG6,,,,,,,Soll [26],[26] sofern per ORDERS reklamiert + 62,Referenz auf Reklamation,SG6,RFF,,00019,,,,Muss, + 63,Referenz auf Reklamation,SG6,RFF,1153,00019,AGI,,Beantragungsnummer,X, + 64,Referenz auf Reklamation,SG6,RFF,1154,00019,,,"Referenz, Identifikation",X [504],[504] Hinweis: Wert aus BGM+Z55 DE1004 der ORDERS mit der die Reklamation einer Definition erfolgt ist + 65,Zählzeitdefinition,SG8,,,,,,,,[24] Wenn SG5 + 66,Zählzeitdefinition,SG8,SEQ,,00039,,,,, + 67,Zählzeitdefinition,SG8,SEQ,1229,00039,Z42,,Zählzeitdefinition,, + 68,Code der Zählzeitdefinition,SG9,,,,,,,, + 69,Code der Zählzeitdefinition,SG9,CCI,,00042,,,,, + 70,Code der Zählzeitdefinition,SG9,CCI,7059,00042,Z39,,Code derZählzeitdefinition,, + 71,Code der Zählzeitdefinition,SG9,CCI,7037,00042,,,Code der Zählzeitdefinition,,[44] Der in diesem Datenlement angegebene Code der Zählzeitdefinition muss innerhalb eines Vorgangs (IDE) eindeutig sein. + 72,Häufigkeit der Übermittlung,SG9,CAV,,00043,,,,, + 73,Häufigkeit der Übermittlung,SG9,CAV,7111,00043,ZE0,,Häufigkeit derÜbermittlung,, + 74,Häufigkeit der Übermittlung,SG9,CAV,7110,00043,Z33,,einmalig zuübermittelndeausgerollte Definition,, + 75,Häufigkeit der Übermittlung,SG9,CAV,7110,,Z34,,jährlich zu übermittelndeausgerollte Definition,, + 76,Übermittelbarkeit der ausgerollten Zählzeitdefinition,SG9,CAV,,00044,,,,, + 77,Übermittelbarkeit der ausgerollten Zählzeitdefinition,SG9,CAV,7111,00044,ZD5,,Übermittelbarkeit derausgerollten Definition,, + 78,Übermittelbarkeit der ausgerollten Zählzeitdefinition,SG9,CAV,7110,00044,Z23,,elektronischübermittelbar,, + 79,Übermittelbarkeit der ausgerollten Zählzeitdefinition,SG9,CAV,7110,,Z24,,elektronisch nichtübermittelbar,, + 80,Ermittlung des Leistungsmaximums bei atypischer Netznutzung,SG9,CAV,,00045,,,,,[22] Wenn MP-ID in SG2 NAD+MS (Nachrichtenabsender) in der Rolle NB + 81,Ermittlung des Leistungsmaximums bei atypischer Netznutzung,SG9,CAV,7111,00045,ZD4,,Ermittlung desLeistungsmaximums beiatypischer Netznutzung,, + 82,Ermittlung des Leistungsmaximums bei atypischer Netznutzung,SG9,CAV,7110,00045,Z25,,Verwendung desHochlastzeitfensters,, + 83,Ermittlung des Leistungsmaximums bei atypischer Netznutzung,SG9,CAV,7110,,Z26,,keine Verwendung desHochlastzeitfensters,, + 84,Bestellbarkeit der Zählzeitdefinition,SG9,CAV,,00046,,,,,"[22] Wenn MP-ID in SG2 NAD+MS (Nachrichtenabsender) in der Rolle NB + [25] Wenn MP-ID in SG2 NAD+MR (Nachrichtenempfänger) in der Rolle LF" + 85,Bestellbarkeit der Zählzeitdefinition,SG9,CAV,7111,00046,ZD7,,Bestellbarkeit derZählzeitdefinition,, + 86,Bestellbarkeit der Zählzeitdefinition,SG9,CAV,7110,00046,Z27,,Zählzeitdefinition istbestellbar,, + 87,Bestellbarkeit der Zählzeitdefinition,SG9,CAV,7110,,Z28,,Zählzeitdefinition istnicht bestellbar,, + 88,Zählzeitdefinitionstyp,SG9,CAV,,00047,,,,,"[22] Wenn MP-ID in SG2 NAD+MS (Nachrichtenabsender) in der Rolle NB + [27] Wenn in SG9 CAV+ZD4+Z26 (keine Verwendung des Hochlastzeitfensters) vorhanden" + 89,Zählzeitdefinitionstyp,SG9,CAV,7111,00047,ZD3,,Zählzeitdefinitionstyp,, + 90,Zählzeitdefinitionstyp,SG9,CAV,7110,00047,Z29,,Wärmepumpe,, + 91,Zählzeitdefinitionstyp,SG9,CAV,7110,,Z30,,Nachtspeicherheizung,, + 92,Zählzeitdefinitionstyp,SG9,CAV,7110,,Z31,,Schwachlastzeitfenster,, + 93,Zählzeitdefinitionstyp,SG9,CAV,7110,,Z32,,sonstigerZählzeitdefinitionstyp,, + 94,Zählzeitdefinitionstyp,SG9,CAV,7110,,Z35,,Hochlastzeitfenster,, + 95,Zählzeitdefinitionstyp,SG9,CAV,7110,00047,,,BeschreibungZählzeitdefinitionstyp,,[21] Wenn in dieser CAV+ZD3 der Wert im DE7110 mit Z32 (sonstiger Zählzeitdefinitionstyp) vorhanden ist + 96,Register der Zählzeitdefinition,SG8,,,,,,,,"[41] Wenn SG8 SEQ+Z42 (Zählzeitdefinition) vorhanden + [2002] Für jeden Code der Zählzeit aus SG8 SEQ+Z42 (Zählzeitdefinition) SG9 CCI+Z39 (Code der Zählzeitdefinition) sind mindestens zwei Register anzugeben, bei denen in dieser SG8 das SG8 RFF+Z27 mit diesem Code gefüllt ist" + 97,Register der Zählzeitdefinition,SG8,SEQ,,00048,,,,, + 98,Register der Zählzeitdefinition,SG8,SEQ,1229,00048,Z41,,Register derZählzeitdefinition,, + 99,Referenz auf eine Zählzeitdefinition,SG8,RFF,,00049,,,,, + 100,Referenz auf eine Zählzeitdefinition,SG8,RFF,1153,00049,Z27,,Code derZählzeitdefinition,, + 101,Referenz auf eine Zählzeitdefinition,SG8,RFF,1154,00049,,,Code der Zählzeitdefinition,, + 102,Code des Zählzeitregister,SG9,,,,,,,, + 103,Code des Zählzeitregister,SG9,CCI,,00050,,,,, + 104,Code des Zählzeitregister,SG9,CCI,7059,00050,Z38,,Code desZählzeitregisters,, + 105,Code des Zählzeitregister,SG9,CCI,7037,00050,,,Code des Zählzeitregisters,, + 106,Schwachlastfähigkeit,SG9,,,,,,,,[22] Wenn MP-ID in SG2 NAD+MS (Nachrichtenabsender) in der Rolle NB + 107,Schwachlastfähigkeit,SG9,CCI,,00051,,,,, + 108,Schwachlastfähigkeit,SG9,CCI,7059,00051,Z10,,Schwachlastfähigkeit,, + 109,Schwachlastfähigkeit,SG9,CCI,7037,00051,Z59,,Nicht-Schwachlast fähig,, + 110,Schwachlastfähigkeit,SG9,CCI,7037,,Z60,,Schwachlast fähig,, + 111,Schaltzeitdefinition,SG8,,,,,,,Muss [24],[24] Wenn SG5 STS+Z36+Z45 (Definitionen werden verwendet) vorhanden + 112,Schaltzeitdefinition,SG8,SEQ,,00052,,,,Muss, + 113,Schaltzeitdefinition,SG8,SEQ,1229,00052,Z69,,Schaltzeitdefinition,X, + 114,Code der Schaltzeitdefinition,SG9,,,,,,,Muss, + 115,Code der Schaltzeitdefinition,SG9,CCI,,00054,,,,Muss, + 116,Code der Schaltzeitdefinition,SG9,CCI,7059,00054,Z52,,Code derSchaltzeitdefinition,X, + 117,Code der Schaltzeitdefinition,SG9,CCI,7037,00054,,,Code der Schaltzeitdefinition,X [42],[42] Der in diesem Datenlement angegebene Code der Schaltzeitdefinition muss innerhalb eines Vorgangs (IDE) eindeutig sein. + 118,Häufigkeit der Übermittlung,SG9,CAV,,00055,,,,Muss, + 119,Häufigkeit der Übermittlung,SG9,CAV,7111,00055,ZE0,,Häufigkeit derÜbermittlung,X, + 120,Häufigkeit der Übermittlung,SG9,CAV,7110,00055,Z33,,einmalig zuübermittelndeausgerollte Definition,X, + 121,Häufigkeit der Übermittlung,SG9,CAV,7110,,Z34,,jährlich zu übermittelndeausgerollte Definition,X, + 122,Übermittelbarkeit der ausgerollten Schaltzeitdefinition,SG9,CAV,,00056,,,,Muss, + 123,Übermittelbarkeit der ausgerollten Schaltzeitdefinition,SG9,CAV,7111,00056,ZD5,,Übermittelbarkeit derausgerollten Definition,X, + 124,Übermittelbarkeit der ausgerollten Schaltzeitdefinition,SG9,CAV,7110,00056,Z23,,elektronischübermittelbar,X, + 125,Übermittelbarkeit der ausgerollten Schaltzeitdefinition,SG9,CAV,7110,,Z24,,elektronisch nichtübermittelbar,X, + 126,Leistungskurvendefinition,SG8,,,,,,,,[24] Wenn SG5 STS+Z36+Z45 (Definitionen werden verwendet) vorhanden + 127,Leistungskurvendefinition,SG8,SEQ,,00058,,,,, + 128,Leistungskurvendefinition,SG8,SEQ,1229,00058,Z70,,Leistungskurvendefinition,, + 129,Code der Leistungskurvendefinition,SG9,,,,,,,, + 130,Code der Leistungskurvendefinition,SG9,CCI,,00060,,,,, + 131,Code der Leistungskurvendefinition,SG9,CCI,7059,00060,Z53,,Code derLeistungskurvendefinition,, + 132,Code der Leistungskurvendefinition,SG9,CCI,7037,00060,,,Code der,,[43] Der in diesem + 133,Häufigkeit der Übermittlung,SG9,CAV,,00061,,,,, + 134,Häufigkeit der Übermittlung,SG9,CAV,7111,00061,ZE0,,Häufigkeit derÜbermittlung,, + 135,Häufigkeit der Übermittlung,SG9,CAV,7110,00061,Z33,,einmalig zuübermittelndeausgerollte Definition,, + 136,Häufigkeit der Übermittlung,SG9,CAV,7110,,Z34,,jährlich zu übermittelndeausgerollte Definition,, + 137,Übermittelbarkeit der ausgerollten Leistungskurvendefinition,SG9,CAV,,00062,,,,, + 138,Übermittelbarkeit der ausgerollten Leistungskurvendefinition,SG9,CAV,7111,00062,ZD5,,Übermittelbarkeit derausgerollten Definition,, + 139,Übermittelbarkeit der ausgerollten Leistungskurvendefinition,SG9,CAV,7110,00062,Z23,,elektronischübermittelbar,, + 140,Übermittelbarkeit der ausgerollten Leistungskurvendefinition,SG9,CAV,7110,,Z24,,elektronisch nichtübermittelbar,, + 141,Nachrichten-Endesegment,,UNT,,00064,,,,Muss, + 142,Nachrichten-Endesegment,,UNT,0074,00064,,,Anzahl der Segmente in einerNachricht,X, + 143,Nachrichten-Endesegment,,UNT,0062,00064,,,Nachrichten-Referenznummer,X, + + ''' +# --- +# name: TestCli.test_kohlrahbi_cli_with_valid_arguments[25009] + ''' + ,Segmentname,Segmentgruppe,Segment,Datenelement,Segment ID,Code,Qualifier,Beschreibung,Bedingungsausdruck,Bedingung + 0,Nachrichten-Kopfsegment,,UNH,,00001,,,,Muss, + 1,Nachrichten-Kopfsegment,,UNH,0062,00001,,,Nachrichten-Referenznummer,X, + 2,Nachrichten-Kopfsegment,,UNH,0065,00001,UTILTS,,Netznutzungszeiten-Nachricht,X, + 3,Nachrichten-Kopfsegment,,UNH,0052,00001,D,,Entwurfs-Version,X, + 4,Nachrichten-Kopfsegment,,UNH,0054,00001,18A,,Ausgabe 2018 - A,X, + 5,Nachrichten-Kopfsegment,,UNH,0051,00001,UN,,UN/CEFACT,X, + 6,Nachrichten-Kopfsegment,,UNH,0057,00001,1.1c,,Versionsnummer derzugrundeliegendenBDEW-Nachrichtenbeschreibung,X, + 7,Beginn der Nachricht,,BGM,,00002,,,,Muss, + 8,Beginn der Nachricht,,BGM,1001,00002,Z59,,AusgerollteZählzeitdefinition,, + 9,Beginn der Nachricht,,BGM,1001,,Z80,,AusgerollteSchaltzeitdefinition,, + 10,Beginn der Nachricht,,BGM,1001,,Z81,,AusgerollteLeistungskurvendefinition,X, + 11,Beginn der Nachricht,,BGM,1004,00002,,,Dokumentennummer,X, + 12,Nachrichtendatum,,DTM,,00003,,,,Muss, + 13,Nachrichtendatum,,DTM,2005,00003,137,,Dokumenten-/Nachrichtendatum/-zeit,X, + 14,Nachrichtendatum,,DTM,2380,00003,,,"Datum oder Uhrzeit oderZeitspanne, Wert",X [931][494],"[494] Das hier genannte Datum muss der Zeitpunkt sein, zu dem das Dokument erstellt wurde, oder ein Zeitpunkt, der davor liegt. + [931] Format: ZZZ = +00" + 15,Nachrichtendatum,,DTM,2379,00003,303,,CCYYMMDDHHMMZZZ,X, + 16,MP-ID Absender,SG2,,,,,,,Muss, + 17,MP-ID Absender,SG2,NAD,,00004,,,,Muss, + 18,MP-ID Absender,SG2,NAD,3035,00004,MS,,Dokumenten-/Nachrichtenausstellerbzw. -absender,X, + 19,MP-ID Absender,SG2,NAD,3039,00004,,,MP-ID,X [1],[1] Nur MP-ID aus Sparte Strom + 20,MP-ID Absender,SG2,NAD,3055,00004,9,,GS1,X, + 21,MP-ID Absender,SG2,NAD,3055,,293,,"DE, BDEW",X, + 22,Ansprechpartner,SG3,,,,,,,Kann, + 23,Ansprechpartner,SG3,CTA,,00005,,,,Muss, + 24,Ansprechpartner,SG3,CTA,3139,00005,IC,,Informationskontakt,X, + 25,Ansprechpartner,SG3,CTA,3412,00005,,,Name vom Ansprechpartner,X, + 26,Kommunikationsverbindung,SG3,COM,,00006,,,,Muss, + 27,Kommunikationsverbindung,SG3,COM,3148,00006,,,Nummer / Adresse,X, + 28,Kommunikationsverbindung,SG3,COM,3155,00006,EM,,Elektronische Post,X [1P0..1], + 29,Kommunikationsverbindung,SG3,COM,3155,,FX,,Telefax,X [1P0..1], + 30,Kommunikationsverbindung,SG3,COM,3155,,TE,,Telefon,X [1P0..1], + 31,Kommunikationsverbindung,SG3,COM,3155,,AJ,,weiteres Telefon,X [1P0..1], + 32,Kommunikationsverbindung,SG3,COM,3155,,AL,,Handy,X [1P0..1], + 33,MP-ID Empfänger,SG2,,,,,,,Muss, + 34,MP-ID Empfänger,SG2,NAD,,00007,,,,Muss, + 35,MP-ID Empfänger,SG2,NAD,3035,00007,MR,,Nachrichtenempfänger,X, + 36,MP-ID Empfänger,SG2,NAD,3039,00007,,,MP-ID,X [1],[1] Nur MP-ID aus Sparte Strom + 37,MP-ID Empfänger,SG2,NAD,3055,00007,9,,GS1,X, + 38,MP-ID Empfänger,SG2,NAD,3055,,293,,"DE, BDEW(Bundesverband derEnergie- undWasserwirtschaft e.V.)",X, + 39,Vorgang,SG5,,,,,,,Muss [523],"[505] Hinweis: Jede ausgerollte Zählzeitdefinition ist in einem eigenen IDE anzugeben + [522] Hinweis: Jede ausgerollte Schaltzeitdefinition ist in einem eigenen IDE anzugeben + [523] Hinweis: Jede ausgerollte Leistungskurvendefinitio n ist in einem eigenen IDE anzugeben" + 40,Vorgang,SG5,IDE,,00008,,,,Muss, + 41,Vorgang,SG5,IDE,7495,00008,24,,Transaktion,X, + 42,Vorgang,SG5,IDE,7402,00008,,,Vorgangsnummer,X, + 43,Code der Definition,SG5,LOC,,00010,,,,Muss, + 44,Code der Definition,SG5,LOC,3227,00010,Z09,,Code der Definition,X, + 45,Code der Definition,SG5,LOC,3225,00010,,,Code der Definition,X [526],"[524] Hinweis: Es ist der Code einer Zählzeitdefinition anzugeben + [525] Hinweis: Es ist der Code einer Schaltzeitdefinition anzugeben + [526] Hinweis: Es ist der Code einer Leistungskurvendefinitio n anzugeben" + 46,Gültigkeitsbeginn der ausgerollten Definition,SG5,DTM,,00012,,,,Muss, + 47,Gültigkeitsbeginn der ausgerollten Definition,SG5,DTM,2005,00012,Z34,,Gültigkeitsbeginn,X, + 48,Gültigkeitsbeginn der ausgerollten Definition,SG5,DTM,2380,00012,,,"Datum oder Uhrzeit oderZeitspanne, Wert",X [931] ∧[947],"[931] Format: ZZZ = +00 + [947] Format: MMDDHHMM = 12312300" + 49,Gültigkeitsbeginn der ausgerollten Definition,SG5,DTM,2379,00012,303,,CCYYMMDDHHMMZZZ,X, + 50,Gültigkeitsende der ausgerollten Definition,SG5,DTM,,00013,,,,Muss [48]Soll [49] ∧[37],"[29] Wenn in SG8 SEQ+Z43 DTM+Z33 (Zählzeitänderungszeitpu nkt) im DE2379 der Code 303 vorhanden + [36] Wenn in SG8 SEQ+Z43 DTM+Z33 (Zählzeitänderungszeitpu nkt) im DE2379 der Code 401 vorhanden + [37] Wenn ein Gültigkeitsende bereits angegeben werden kann." + 51,Gültigkeitsende der ausgerollten Definition,SG5,DTM,2005,00013,Z35,,Gültigkeitsende,X, + 52,Gültigkeitsende der ausgerollten Definition,SG5,DTM,2380,00013,,,"Datum oder Uhrzeit oderZeitspanne, Wert",X [931] ∧[947] [30],"[30] Der Wert von CCYY in diesem DE muss genau um eins höher sein, als der Wert CCYY des SG5 DTM+Z34 (Gültigkeitsbeginn) DE2380 + [931] Format: ZZZ = +00 + [947] Format: MMDDHHMM = 12312300" + 53,Gültigkeitsende der ausgerollten Definition,SG5,DTM,2379,00013,303,,CCYYMMDDHHMMZZZ,X, + 54,Versionsangabe,SG5,DTM,,00014,,,,Muss, + 55,Versionsangabe,SG5,DTM,2005,00014,293,,Fertigstellungsdatum/-zeit,X, + 56,Versionsangabe,SG5,DTM,2380,00014,,,"Datum oder Uhrzeit oderZeitspanne, Wert",X [931],[931] Format: ZZZ = +00 + 57,Versionsangabe,SG5,DTM,2379,00014,304,,CCYYMMDDHHMMSSZZZ,X, + 58,Prüfidentifikator,SG6,,,,,,,Muss, + 59,Prüfidentifikator,SG6,RFF,,00018,,,,Muss, + 60,Prüfidentifikator,SG6,RFF,1153,00018,Z13,,Prüfidentifikator,X, + 61,Prüfidentifikator,SG6,RFF,1154,00018,25005,,AusgerollteZählzeitdefinition,, + 62,Prüfidentifikator,SG6,RFF,1154,,25008,,AusgerollteSchaltzeitdefinition,, + 63,Prüfidentifikator,SG6,RFF,1154,,25009,,AusgerollteLeistungskurvendefinition,X, + 64,Referenz auf Reklamation,SG6,,,,,,,Soll [26],[26] sofern per ORDERS reklamiert + 65,Referenz auf Reklamation,SG6,RFF,,00019,,,,Muss, + 66,Referenz auf Reklamation,SG6,RFF,1153,00019,AGI,,Beantragungsnummer,X, + 67,Referenz auf Reklamation,SG6,RFF,1154,00019,,,"Referenz, Identifikation",X [504],[504] Hinweis: Wert aus BGM+Z55 DE1004 der ORDERS mit der die Reklamation einer Definition erfolgt ist + 68,Operator / Operation,SG9,CAV,,00030,,,,, + 69,Operator / Operation,SG9,CAV,7111,00030,Z83,,Positivwert,;, + 70,Zählzeitdefinition,SG8,,,,,,,,"[510] Hinweis: Für jeden Zählzeitänderungszeitpu nkt (SG8 DTM+Z33) ist diese Sementgruppe einmal anzugeben + [511] Hinweis: Der Zählzeitänderungszeitpu nkt (SG8DTM+Z33) dieser SG8 darf in keiner anderen SG8 „Zählzeitdefinition“ wiederholt werden + [512] Hinweis: Wenn der Code 303 im DE2379 des Zählzeitänderungszeitpu nkt (SG8 DTM+Z33) genutzt wird, muss genau ein Wert im DE2380 des Zählzeitänderungszeitpu nkt (SG8 DTM+Z33) identisch mit dem Wert aus DE2380 des" + 71,Zählzeitdefinition,SG8,SEQ,,00039,,,,, + 72,Zählzeitdefinition,SG8,SEQ,1229,00039,Z43,,AusgerollteZählzeitdefinition,, + 73,Zählzeitänderungszeitpunkt,SG8,DTM,,00040,,,,, + 74,Zählzeitänderungszeitpunkt,SG8,DTM,2005,00040,Z33,,Zählzeitänderungszeitpunkt,, + 75,Zählzeitänderungszeitpunkt,SG8,DTM,2380,00040,,,"Datum oder Uhrzeit oderZeitspanne, Wert",,"[31] Wenn im DE2379 dieses Segments der Code 303 vorhanden + [32] Der Zeitpunkt in diesem DE muss ≥ dem Zeitpunkt aus dem DE2380 des Gültigkeitsbeginn der ausgerollten Definition (SG5 DTM+Z34) sein + [33] Der Zeitpunkt in diesem DE muss ≤ dem Zeitpunkt aus dem DE2380 des Gültigkeitsende der ausgerollten Definition (SG5 DTM+Z35) sein + [34] Wenn im DE2379 dieses Segments der Code 401 vorhanden + [507] Hinweis: Es ist die Zeit nach der deutschen gesetzlichen Zeit anzugeben" + 76,Zählzeitänderungszeitpunkt,SG8,DTM,2379,00040,303,,CCYYMMDDHHMMZZZ,, + 77,Zählzeitänderungszeitpunkt,SG8,DTM,2379,,401,,HHMM,,"[50] In jedem DE2379 dieses DTM-Segments innerhalb eines IDE+24 (Vorgangs) muss der gleiche Code angegeben werden + [527] Hinweis: Dieser Code ist anzugeben, wenn es sich um eine einmalig zu übermittelnde Definition handelt + [528] Hinweis: Dieser Code ist anzugeben, wenn es sich um eine jährlich zu übermittelnde Definition handelt" + 78,Zählendes Register,SG8,RFF,,00041,,,,, + 79,Zählendes Register,SG8,RFF,1153,00041,Z28,,Code des zählendenRegisters,, + 80,Zählendes Register,SG8,RFF,1154,00041,,,Code des zählenden Registers,, + 81,Schaltzeitdefinition,SG8,,,,,,,,"[514] Hinweis: Für jeden Schaltzeitänderungszeitp unkt (SG8 DTM+Z44) ist diese Sementgruppe einmal anzugeben + [515] Hinweis: Kein Schaltzeitänderungszeitp unkt (SG8 DTM+Z44) darf mehrfach vorkommen + [516] Hinweis: Wenn der Code 303 im DE2379 des Schaltzeitänderungszeitp" + 82,Schaltzeitdefinition,SG8,SEQ,,00052,,,,, + 83,Schaltzeitdefinition,SG8,SEQ,1229,00052,Z73,,AusgerollteSchaltzeitdefinition,, + 84,Schaltzeitänderungszeitpun kt,SG8,DTM,,00053,,,,, + 85,Schaltzeitänderungszeitpun kt,SG8,DTM,2005,00053,Z44,,Schaltzeitänderungszeitpunkt,, + 86,Schaltzeitänderungszeitpun kt,SG8,DTM,2380,00053,,,"Datum oder Uhrzeit oderZeitspanne, Wert",,"[31] Wenn im DE2379 dieses Segments der Code 303 vorhanden + [32] Der Zeitpunkt in diesem DE muss ≥ dem Zeitpunkt aus dem DE2380 des Gültigkeitsbeginn der ausgerollten Definition (SG5 DTM+Z34) sein + [33] Der Zeitpunkt in diesem DE muss ≤ dem Zeitpunkt aus dem DE2380 des Gültigkeitsende der ausgerollten Definition (SG5 DTM+Z35) sein" + 87,Schaltzeitänderungszeitpun kt,SG8,DTM,2379,00053,303,,CCYYMMDDHHMMZZZ,, + 88,Schaltzeitänderungszeitpun kt,SG8,DTM,2379,,401,,HHMM,,"[50] In jedem DE2379 dieses DTM-Segments innerhalb eines IDE+24 (Vorgangs) muss der gleiche Code angegeben werden + [527] Hinweis: Dieser Code ist anzugeben, wenn es sich um eine einmalig zu übermittelnde Definition handelt + [528] Hinweis: Dieser Code ist anzugeben, wenn es sich um eine jährlich zu übermittelnde Definition handelt" + 89,Schalthandlung an der Lokation,SG9,,,,,,,, + 90,Schalthandlung an der Lokation,SG9,CCI,,00057,,,,, + 91,Schalthandlung an der Lokation,SG9,CCI,7059,00057,Z58,,Schalthandlung,, + 92,Schalthandlung an der Lokation,SG9,CCI,7037,00057,ZF4,,Leistung an der Lokationan,, + 93,Schalthandlung an der Lokation,SG9,CCI,7037,,ZF5,,Leistung an der Lokationaus,, + 94,Leistungskurvendefinition,SG8,,,,,,,Muss [518]∧ [519] ∧([520] ⊻,[518] Hinweis: Für jeden Leistungskurvenänderun gszeitpunkt (SG8 + 95,Leistungskurvendefinition,SG8,SEQ,,00058,,,,Muss, + 96,Leistungskurvendefinition,SG8,SEQ,1229,00058,Z74,,AusgerollteLeistungskurvendefinition,X, + 97,Leistungskurvenänderungsz eitpunkt,SG8,DTM,,00059,,,,Muss, + 98,Leistungskurvenänderungsz eitpunkt,SG8,DTM,2005,00059,Z45,,Leistungskurvenänderungszeitpunkt,X, + 99,Leistungskurvenänderungsz eitpunkt,SG8,DTM,2380,00059,,,"Datum oder Uhrzeit oderZeitspanne, Wert",X ([931] [31]∧ [32] ∧[33]) ⊻(([964] ∧[965] [34])∧ [507]),"[31] Wenn im DE2379 dieses Segments der Code 303 vorhanden + [32] Der Zeitpunkt in diesem DE muss ≥ dem Zeitpunkt aus dem DE2380 des Gültigkeitsbeginn der" + 100,Leistungskurvenänderungsz eitpunkt,SG8,DTM,2379,00059,303,,CCYYMMDDHHMMZZZ,X [50] ∧[528], + 101,Leistungskurvenänderungsz eitpunkt,SG8,DTM,2379,,401,,HHMM,X [50] ∧[527],"[50] In jedem DE2379 dieses DTM-Segments innerhalb eines IDE+24 (Vorgangs) muss der gleiche Code angegeben werden + [527] Hinweis: Dieser Code ist anzugeben, wenn es sich um eine einmalig zu übermittelnde Definition handelt + [528] Hinweis: Dieser Code ist anzugeben, wenn es sich um eine jährlich zu übermittelnde Definition handelt" + 102,oberer Schwellwert,SG11,,,,,,,Muss, + 103,oberer Schwellwert,SG11,QTY,,00063,,,,Muss, + 104,oberer Schwellwert,SG11,QTY,6063,00063,Z40,,oberer Schwellwert,X, + 105,oberer Schwellwert,SG11,QTY,6060,00063,,,Mengenangabe in %,X [930] ∧[963],"[930] Format: max. 2 Nachkommastellen + [963] Format: Möglicher Wert: ≤ 100" + 106,oberer Schwellwert,SG11,QTY,6411,00063,P1,,Prozent,X, + 107,Nachrichten-Endesegment,,UNT,,00064,,,,Muss, + 108,Nachrichten-Endesegment,,UNT,0074,00064,,,Anzahl der Segmente in einerNachricht,X, + 109,Nachrichten-Endesegment,,UNT,0062,00064,,,Nachrichten-Referenznummer,X, + + ''' +# --- +# name: TestCli.test_kohlrahbi_cli_with_valid_arguments[27001] + ''' + ,Segmentname,Segmentgruppe,Segment,Datenelement,Segment ID,Code,Qualifier,Beschreibung,Bedingungsausdruck,Bedingung + 0,Nachrichten-Kopfsegment,,UNH,,00001,,,,Muss [12],"[12] je UNB ist nur eine Nachricht mit BGM+Z04 in der Übertragungsdatei erlaubt (nur eine Nachricht je Übertragungsdatei) + [14] je UNB ist maximal je Code aus DE1001 eine Nachricht in der Übertragungsdatei erlaubt" + 1,Nachrichten-Kopfsegment,,UNH,0062,00001,,,Nachrichten-Referenznummer,X, + 2,Nachrichten-Kopfsegment,,UNH,0065,00001,PRICAT,,Preisliste/Katalog,X, + 3,Nachrichten-Kopfsegment,,UNH,0052,00001,D,,Entwurfs-Version,X, + 4,Nachrichten-Kopfsegment,,UNH,0054,00001,20B,,Ausgabe 2020 - B,X, + 5,Nachrichten-Kopfsegment,,UNH,0051,00001,UN,,UN/CEFACT,X, + 6,Nachrichten-Kopfsegment,,UNH,0057,00001,2.0c,,Versionsnummer derzugrundeliegendenBDEW-Nachrichtenbeschreibung,x, + 7,Beginn der Nachricht,,BGM,,00002,,,,Muss, + 8,Beginn der Nachricht,,BGM,1001,00002,Z04,,Ausgleichsenergiepreis,X, + 9,Beginn der Nachricht,,BGM,1001,,Z32,,Preisblatt,, + 10,Beginn der Nachricht,,BGM,1001,,Z77,,PreisblattKonfigurationen,,"[30] wenn MP-ID in SG2 NAD+MR in der Rolle LF + [33] wenn der Zeitpunkt im DTM+157 DE2380 ≥ 01.01. 2024 00:00 Uhr gesetzlicher deutscher Zeit + [36] wenn MP-ID in SG2 NAD+MR in der Rolle NB" + 11,Beginn der Nachricht,,BGM,1004,00002,,,Dokumentennummer,X, + 12,Beginn der Nachricht,,BGM,1373,00002,11,,Dokument nichtverfügbar,,[35] Wenn das in DE1001 angegebene Preisblatt vom MSB nicht genutzt wird. + 13,Betrachtungszeitintervall,,DTM,,00003,,,,Muss, + 14,Betrachtungszeitintervall,,DTM,2005,00003,492,,"Bilanzierungsdatum, -zeit, -periode",X, + 15,Betrachtungszeitintervall,,DTM,2380,00003,,,"Datum oder Uhrzeit oderZeitspanne, Wert",X, + 16,Betrachtungszeitintervall,,DTM,2379,00003,610,,CCYYMM,X, + 17,Nachrichtendatum,,DTM,,00004,,,,Muss, + 18,Nachrichtendatum,,DTM,2005,00004,137,,Dokumenten-/Nachrichtendatum/-zeit,X, + 19,Nachrichtendatum,,DTM,2380,00004,,,"Datum oder Uhrzeit oderZeitspanne, Wert",X [931] [494],"[494] Das hier genannte Datum muss der Zeitpunkt sein, zu dem das Dokument erstellt wurde, oder ein Zeitpunkt, der davor liegt + [931] Format: ZZZ = +00" + 20,Nachrichtendatum,,DTM,2379,00004,303,,CCYYMMDDHHMMZZZ,X, + 21,Gültigkeitsbeginn,,DTM,,00005,,,,, + 22,Gültigkeitsbeginn,,DTM,2005,00005,157,,"Gültigkeit, Beginndatum",, + 23,Gültigkeitsbeginn,,DTM,2380,00005,,,"Datum oder Uhrzeit oderZeitspanne, Wert",,"[43] Wenn BGM DE1001 = Z32 und LIN DE7140 im Format n1-n2-n1-n3, dann muss der hier genannte Zeitpunkt ≥ 01. 01.2024 00:00 Uhr gesetzlicher deutscher Zeit sein + [44] Wenn BGM DE1001 = Z77, dann muss der hier genannte Zeitpunkt ≥ 01.10. 2023 00:00 Uhr gesetzlicher deutscher Zeit sein. + [47] Wenn BGM DE1001 = Z32 und LIN DE7140 im Format n13, dann muss der hier genannte Zeitpunkt < 01.01. 2024 00:00 Uhr gesetzlicher deutscher Zeit sein" + 24,Gültigkeitsbeginn,,DTM,2379,00005,303,,CCYYMMDDHHMMZZZ,, + 25,Vorgängerversion,SG1,,,,,,,,[1] Wenn Vorgängerversion vorhanden + 26,Vorgängerversion,SG1,RFF,,00006,,,,, + 27,Vorgängerversion,SG1,RFF,1153,00006,ACW,,Referenznummer einervorangegangenenNachricht,, + 28,Vorgängerversion,SG1,RFF,1154,00006,,,"Referenz, Identifikation",,[504] Hinweis: Dokumentennummer der PRICAT + 29,Prüfidentifikator,SG1,,,,,,,Muss, + 30,Prüfidentifikator,SG1,RFF,,00007,,,,Muss, + 31,Prüfidentifikator,SG1,RFF,1153,00007,Z13,,Prüfidentifikator,X, + 32,Prüfidentifikator,SG1,RFF,1154,00007,27001,,Übermittlung derAusgleichsenergiepreise,X, + 33,Prüfidentifikator,SG1,RFF,1154,,27002,,Preisblatt MSB-Leistungen,, + 34,Empfänger-ID,SG2,,,,,,,Muss, + 35,Empfänger-ID,SG2,NAD,,00008,,,,Muss, + 36,Empfänger-ID,SG2,NAD,3035,00008,MR,,Nachrichtenempfänger,X, + 37,Empfänger-ID,SG2,NAD,3039,00008,,,"Beteiligter, Identifikation",X [19],[19] Nur MP-ID aus Sparte Strom + 38,Empfänger-ID,SG2,NAD,3055,00008,9,,GS1,X, + 39,Empfänger-ID,SG2,NAD,3055,,293,,"DE, BDEW(Bundesverband derEnergie- undWasserwirtschaft e.V.)",X, + 40,Sender-ID,SG2,,,,,,,Muss, + 41,Sender-ID,SG2,NAD,,00009,,,,Muss, + 42,Sender-ID,SG2,NAD,3035,00009,MS,,Dokumenten-/Nachrichtenausstellerbzw. -absender,X, + 43,Sender-ID,SG2,NAD,3039,00009,,,"Beteiligter, Identifikation",X [19],[19] Nur MP-ID aus Sparte Strom + 44,Sender-ID,SG2,NAD,3055,00009,9,,GS1,X, + 45,Sender-ID,SG2,NAD,3055,,293,,"DE, BDEW(Bundesverband derEnergie- undWasserwirtschaft e.V.)",X, + 46,Regelzone,SG2,LOC,,00010,,,,Muss, + 47,Regelzone,SG2,LOC,3227,00010,231,,Regelzone,X, + 48,Regelzone,SG2,LOC,3225,00010,,,"Ortsangabe, Nummer",X, + 49,Ansprechpartner,SG4,,,,,,,Kann, + 50,Ansprechpartner,SG4,CTA,,00011,,,,Muss, + 51,Ansprechpartner,SG4,CTA,3139,00011,IC,,Informationskontakt,X, + 52,Ansprechpartner,SG4,CTA,3412,00011,,,Kontakt,X, + 53,Kommunikationsverbindung,SG4,COM,,00012,,,,Muss, + 54,Kommunikationsverbindung,SG4,COM,3148,00012,,,"Kommunikationsadresse,Identifikation",X (([939][37]) ∨([940][38])) ∧[519],"[37] Wenn im DE3155 in demselben COM der Code EM vorhanden ist + [38] Wenn im DE3155 in demselben COM der Code TE / FX / AJ / AL vorhanden ist + [519] Hinweis: Es darf nur eine Information im DE3148 übermittelt werden + [939] Format: Die Zeichenkette muss die Zeichen @ und . enthalten + [940] Format: Die Zeichenkette muss mit dem Zeichen + beginnen und danach dürfen nur noch Ziffern folgen" + 55,Kommunikationsverbindung,SG4,COM,3155,00012,EM,,E-Mail,X [1P0..1], + 56,Kommunikationsverbindung,SG4,COM,3155,,FX,,Telefax,X [1P0..1], + 57,Kommunikationsverbindung,SG4,COM,3155,,TE,,Telefon,X [1P0..1], + 58,Kommunikationsverbindung,SG4,COM,3155,,AJ,,weiteres Telefon,X [1P0..1], + 59,Kommunikationsverbindung,SG4,COM,3155,,AL,,Handy,X [1P0..1], + 60,Währungsangaben,SG6,,,,,,,Muss,[9] Wenn BGM DE1373 =11 nicht vorhanden + 61,Währungsangaben,SG6,CUX,,00013,,,,Muss, + 62,Währungsangaben,SG6,CUX,6347,00013,2,,Referenzwährung,X, + 63,Währungsangaben,SG6,CUX,6345,00013,EUR,,Euro,X, + 64,Währungsangaben,SG6,CUX,6343,00013,8,,Währung der Preisliste,X, + 65,Produktgruppen- Information,SG17,,,,,,,Muss,[9] Wenn BGM DE1373 =11 nicht vorhanden + 66,Produktgruppen- Information,SG17,PGI,,00014,,,,Muss, + 67,Produktgruppen- Information,SG17,PGI,5379,00014,9,,keine Gruppe genutzt,X, + 68,Positionsdaten,SG36,,,,,,,Muss, + 69,Positionsdaten,SG36,LIN,,00015,,,,Muss, + 70,Positionsdaten,SG36,LIN,1082,00015,,,Positionsnummer,X [911],"[911] Format: Mögliche Werte: 1 bis n, je Nachricht oder Segmentgruppe bei 1 beginnend und fortlaufend aufsteigend" + 71,Positionsdaten,SG36,LIN,7140,00015,,,Produkt-/Leistungsnummer,X [941] ∧ [39],"[31] wenn BGM DE1001 = Z32 + [32] wenn der Zeitpunkt im DTM+157 DE2380 < 01.01. 2024 00:00 Uhr gesetzlicher deutscher Zeit + [33] wenn der Zeitpunkt im DTM+157 DE2380 ≥ 01.01. 2024 00:00 Uhr gesetzlicher deutscher Zeit + [34] wenn BGM DE1001 = Z77 + [39] Es sind nur Werte aus der EDI@Energy Codeliste der Artikelnummern und Artikel-ID erlaubt, die in der Spalte MaBiS ein X haben + [40] Es sind nur Werte aus der EDI@Energy Codeliste der Artikelnummern und Artikel-ID erlaubt, die in der Spalte H ein X haben + [45] Es sind nur Werte aus der EDI@Energy Codeliste der Artikelnummern und Artikel-ID erlaubt, die in dieser in Kapitel ""Abrechnung Messstellenbetrieb für die Sparte Strom"" genannt sind + [46] Es sind nur Werte aus der EDI@Energy Codeliste der Artikelnummern und Artikel-ID erlaubt, die in dieser in Kapitel ""Artikel-ID für den Universalbestellprozess für die Sparte Strom"" genannt sind + [941] Format: Artikelnummer + [942] Format: n1-n2-n1-n3 + [959] Format: n13-n2" + 72,Positionsdaten,SG36,LIN,7143,00015,Z01,,Artikelnummer,X,[31] wenn BGM DE1001 = Z32 + 73,Preisschlüsselstamm,SG36,PIA,,00016,,,,,"[31] wenn BGM DE1001 = Z32 + [32] wenn der Zeitpunkt im DTM+157 DE2380 < 01.01. 2024 00:00 Uhr gesetzlicher deutscher Zeit" + 74,Preisschlüsselstamm,SG36,PIA,4347,00016,1,,Zusätzliche Identifikation,, + 75,Preisschlüsselstamm,SG36,PIA,7140,00016,,,Code des Preisschlüsselstamms,, + 76,Preisschlüsselstamm,SG36,PIA,7143,00016,Z06,,Preisschlüsselstamm,, + 77,Produktbeschreibung,SG36,IMD,,00017,,,,,"[31] wenn BGM DE1001 = Z32 + [32] wenn der Zeitpunkt im DTM+157 DE2380 < 01.01. 2024 00:00 Uhr gesetzlicher deutscher Zeit" + 78,Produktbeschreibung,SG36,IMD,7077,00017,C,,Code (aus der Liste einercodepflegendenOrganisation),, + 79,Produktbeschreibung,SG36,IMD,7077,,X,,Teilstrukturiert (Codeund Text),,"[6] Wenn in dieser SG36 LIN in DE7140 9990001000798 vorhanden + [7] Wenn in dieser SG36 LIN in DE7140 9990001000798 nicht vorhanden" + 80,Produktbeschreibung,SG36,IMD,7081,00017,Z15,,POG bei verbrauchenderMarktlokation > 100.000kWh/a mit iMS,, + 81,Produktbeschreibung,SG36,IMD,7081,,Z16,,POG bei verbrauchenderMarktlokation ]50.000kWh/a; 100.000 kWh/a]mit iMS,, + 82,Produktbeschreibung,SG36,IMD,7081,,Z17,,POG bei verbrauchenderMarktlokation ]20.000kWh/a; 50.000 kWh/a]mit iMS,, + 83,Produktbeschreibung,SG36,IMD,7081,,Z18,,POG bei verbrauchenderMarktlokation ]10.000kWh/a; 20.000 kWh/a]mit iMS,, + 84,Produktbeschreibung,SG36,IMD,7081,,Z19,,POG bei verbrauchenderMarktlokation mitunterbrechbarenVerbrauchseinrichtungnach § 14a EnWG mitiMS,, + 85,Produktbeschreibung,SG36,IMD,7081,,Z20,,POG bei verbrauchender,,"[4] Wenn SG36 IMD+C in diesem IMD vorhanden + [5] Wenn SG36 IMD+X in diesem IMD vorhanden" + 86,Produktbeschreibung,SG36,IMD,7009,00017,,,"Produkt-/Leistungsbeschreibung,Code",, + 87,Produktbeschreibung,SG36,IMD,7009,,Z08,,Höchstspannung,, + 88,Produktbeschreibung,SG36,IMD,7009,,Z09,,Hochspannung,, + 89,Produktbeschreibung,SG36,IMD,7009,,Z10,,Mittelspannung,, + 90,Produktbeschreibung,SG36,IMD,7009,,Z11,,Niederspannung,,[2] Wenn in dieser SG36 LIN in DE7140 9990001000813 vorhanden + 91,Produktbeschreibung,SG36,IMD,7008,00017,,,Produkt-/Leistungsbeschreibung,,[3] Wenn IMD+X vorhanden + 92,Preisangaben,SG40,,,,,,,Muss, + 93,Preisangaben,SG40,PRI,,00018,,,,Muss, + 94,Preisangaben,SG40,PRI,5125,00018,CAL,,Berechnungspreis,X, + 95,Preisangaben,SG40,PRI,5118,00018,,,"Preis, Betrag",X [912] [502],"[502] Hinweis: Preis in Euro je MWh + [513] Hinweis: Die zum Preis gehörende Einheit ist in der Codeliste definiert " + 96,Preisangaben,SG40,PRI,5284,00018,,,"Einzelpreisbasis, Menge",X [929] [503],"[503] Hinweis: Hier ist immer der Wert 1000 einzutragen, da in DE5118 der Preis in €/MWh angegeben wird. + [929] Format: Möglicher Wert: 1000" + 97,Preisangaben,SG40,PRI,6411,00018,ANN,,Jahr,,"[31] wenn BGM DE1001 = Z32 + [32] wenn der Zeitpunkt im DTM+157 DE2380 < 01.01. 2024 00:00 Uhr gesetzlicher deutscher Zeit" + 98,Datum/Uhrzeit/Zeitspanne,SG40,DTM,,00019,,,,Muss, + 99,Datum/Uhrzeit/Zeitspanne,SG40,DTM,2005,00019,163,,"Verarbeitung,Beginndatum/-zeit",X, + 100,Datum/Uhrzeit/Zeitspanne,SG40,DTM,2005,,164,,"Verarbeitung,Endedatum/-zeit",X, + 101,Datum/Uhrzeit/Zeitspanne,SG40,DTM,2380,00019,,,"Datum oder Uhrzeit oderZeitspanne, Wert",X [931] [495],"[495] Der Zeitpunkt muss ≤ dem Wert im DE2380 des DTM+137 sein + [931] Format: ZZZ = +00" + 102,Datum/Uhrzeit/Zeitspanne,SG40,DTM,2379,00019,303,,CCYYMMDDHHMMZZZ,X, + 103,Nachrichten-Endesegment,,UNT,,00024,,,,Muss, + 104,Nachrichten-Endesegment,,UNT,0074,00024,,,Anzahl der Segmente in einerNachricht,X, + 105,Nachrichten-Endesegment,,UNT,0062,00024,,,Nachrichten-Referenznummer,X, + + ''' +# --- +# name: TestCli.test_kohlrahbi_cli_with_valid_arguments[27003] + ''' + ,Segmentname,Segmentgruppe,Segment,Datenelement,Segment ID,Code,Qualifier,Beschreibung,Bedingungsausdruck,Bedingung + 0,Nachrichten-Kopfsegment,,UNH,,00001,,,,Muss [14],[14] je UNB ist maximal je Code aus DE1001 eine Nachricht in der Übertragungsdatei erlaubt + 1,Nachrichten-Kopfsegment,,UNH,0062,00001,,,Nachrichten-Referenznummer,X, + 2,Nachrichten-Kopfsegment,,UNH,0065,00001,PRICAT,,Preisliste/Katalog,X, + 3,Nachrichten-Kopfsegment,,UNH,0052,00001,D,,Entwurfs-Version,X, + 4,Nachrichten-Kopfsegment,,UNH,0054,00001,20B,,Ausgabe 2020 - B,X, + 5,Nachrichten-Kopfsegment,,UNH,0051,00001,UN,,UN/CEFACT,X, + 6,Nachrichten-Kopfsegment,,UNH,0057,00001,2.0c,,Versionsnummer derzugrundeliegendenBDEW-Nachrichtenbeschreibung,x, + 7,Beginn der Nachricht,,BGM,,00002,,,,Muss, + 8,Beginn der Nachricht,,BGM,1001,00002,Z54,,Preisblatt Sperren /Entsperren undVerzugskosten,X, + 9,Beginn der Nachricht,,BGM,1001,,Z64,,Preisblatt Netznutzungohne gemeindespezifischeKonzessionsabgaben,X [492], + 10,Beginn der Nachricht,,BGM,1001,,Z67,,Preisblatt Blindarbeit,X [492], + 11,Beginn der Nachricht,,BGM,1001,,Z70,,Preisblatt Netznutzung:GemeindespezifischeKonzessionsabgaben,X [492],[492] wenn MP-ID in NAD+MR aus Sparte Strom + 12,Beginn der Nachricht,,BGM,1004,00002,,,Dokumentennummer,X, + 13,Beginn der Nachricht,,BGM,1373,00002,,,,11,[8] Wenn das in DE1001 angegebene Preisblatt vom NB nicht genutzt wird. + 14,Nachrichtendatum,,DTM,,00004,,,,Muss, + 15,Nachrichtendatum,,DTM,2005,00004,137,,Dokumenten-/Nachrichtendatum/-zeit,X, + 16,Nachrichtendatum,,DTM,2380,00004,,,"Datum oder Uhrzeit oderZeitspanne, Wert",X [931] [494],"[494] Das hier genannte Datum muss der Zeitpunkt sein, zu dem das Dokument erstellt wurde, oder ein Zeitpunkt, der davor liegt + [931] Format: ZZZ = +00" + 17,Nachrichtendatum,,DTM,2379,00004,303,,CCYYMMDDHHMMZZZ,X, + 18,Gültigkeitsbeginn,,DTM,,00005,,,,Muss, + 19,Gültigkeitsbeginn,,DTM,2005,00005,157,,"Gültigkeit, Beginndatum",X, + 20,Gültigkeitsbeginn,,DTM,2380,00005,,,"Datum oder Uhrzeit oderZeitspanne, Wert",X [UB1], + 21,Gültigkeitsbeginn,,DTM,2379,00005,303,,CCYYMMDDHHMMZZZ,X, + 22,Vorgängerversion,SG1,,,,,,,Soll [1],[1] Wenn Vorgängerversion vorhanden + 23,Vorgängerversion,SG1,RFF,,00006,,,,Muss, + 24,Vorgängerversion,SG1,RFF,1153,00006,ACW,,Referenznummer einervorangegangenenNachricht,X, + 25,Vorgängerversion,SG1,RFF,1154,00006,,,"Referenz, Identifikation",X [504],[504] Hinweis: + 26,Prüfidentifikator,SG1,,,,,,,Muss, + 27,Prüfidentifikator,SG1,RFF,,00007,,,,Muss, + 28,Prüfidentifikator,SG1,RFF,1153,00007,Z13,,Prüfidentifikator,X, + 29,Prüfidentifikator,SG1,RFF,1154,00007,27003,,Preisblatt NB-Leistungen,X, + 30,Empfänger-ID,SG2,,,,,,,Muss, + 31,Empfänger-ID,SG2,NAD,,00008,,,,Muss, + 32,Empfänger-ID,SG2,NAD,3035,00008,,,,MR, + 33,Empfänger-ID,SG2,NAD,3039,00008,,,"Beteiligter, Identifikation",X, + 34,Empfänger-ID,SG2,NAD,3055,00008,9,,GS1,X, + 35,Empfänger-ID,SG2,NAD,3055,,293,,"DE, BDEW (Bundesverbandder Energie- undWasserwirtschaft e.V.)",X, + 36,Empfänger-ID,SG2,NAD,3055,,332,,"DE, DVGW Service &Consult GmbH",X, + 37,Sender-ID,SG2,,,,,,,Muss, + 38,Sender-ID,SG2,NAD,,00009,,,,Muss, + 39,Sender-ID,SG2,NAD,3035,00009,Nachrichtenaussteller bzw.-absender,,,MS, + 40,Sender-ID,SG2,NAD,3039,00009,,,"Beteiligter, Identifikation",X, + 41,Sender-ID,SG2,NAD,3055,00009,9,,GS1,X, + 42,Sender-ID,SG2,NAD,3055,,293,,"DE, BDEW (Bundesverbandder Energie- undWasserwirtschaft e.V.)",X, + 43,Sender-ID,SG2,NAD,3055,,332,,"DE, DVGW Service &Consult GmbH",X, + 44,Ansprechpartner,SG4,,,,,,,Kann, + 45,Ansprechpartner,SG4,CTA,,00011,,,,Muss, + 46,Ansprechpartner,SG4,CTA,3139,00011,,,,IC, + 47,Ansprechpartner,SG4,CTA,3412,00011,,,Kontakt,X, + 48,Kommunikationsverbindung,SG4,COM,,00012,,,,Muss, + 49,Kommunikationsverbindung,SG4,COM,3148,00012,,,"Kommunikationsadresse,Identifikation",X (([939][37]) ∨ ([940][38])) ∧ [519],"[37] Wenn im DE3155 in demselben COM der Code EM vorhanden ist + [38] Wenn im DE3155 in demselben COM der Code TE / FX / AJ / AL vorhanden ist + [519] Hinweis: Es darf nur eine Information im DE3148 übermittelt werden + [939] Format: Die Zeichenkette muss die Zeichen @ und . enthalten + [940] Format: Die Zeichenkette muss mit dem Zeichen + beginnen und danach dürfen nur noch Ziffern folgen" + 50,Kommunikationsverbindung,SG4,COM,3155,00012,EM,,E-Mail,X [1P0..1], + 51,Kommunikationsverbindung,SG4,COM,3155,,FX,,Telefax,X [1P0..1], + 52,Kommunikationsverbindung,SG4,COM,3155,,TE,,Telefon,X [1P0..1], + 53,Kommunikationsverbindung,SG4,COM,3155,,AJ,,weiteres Telefon,X [1P0..1], + 54,Kommunikationsverbindung,SG4,COM,3155,,AL,,Handy,X [1P0..1], + 55,Währungsangaben,SG6,,,,,,,Muss [9],[9] Wenn BGM DE1373 =11 nicht vorhanden + 56,Währungsangaben,SG6,CUX,,00013,,,,Muss, + 57,Währungsangaben,SG6,CUX,6347,00013,2,,Referenzwährung,X, + 58,Währungsangaben,SG6,CUX,6345,00013,EUR,,Euro,X, + 59,Währungsangaben,SG6,CUX,6343,00013,8,,Währung der Preisliste,X, + 60,Produktgruppen- Information,SG17,,,,,,,Muss [9] ∧ [27],"[9] Wenn BGM DE1373 =11 nicht vorhanden + [27] Wenn BGM DE1001 = Z70 nicht vorhanden" + 61,Produktgruppen- Information,SG17,PGI,,00014,,,,Muss, + 62,Produktgruppen- Information,SG17,PGI,5379,00014,,,,9, + 63,Positionsdaten,SG36,,,,,,,Muss, + 64,Positionsdaten,SG36,LIN,,00015,,,,Muss, + 65,Positionsdaten,SG36,LIN,1082,00015,,,Positionsnummer,X [911],"[911] Format: Mögliche Werte: 1 bis n, je Nachricht oder Segmentgruppe bei 1 beginnend und fortlaufend aufsteigend" + 66,Positionsdaten,SG36,LIN,7140,00015,,,Produkt-/Leistungsnummer,X [942] ∧ [41],"[41] Es sind nur Werte aus der EDI@Energy Codeliste der Artikelnummern und Artikel-ID erlaubt, die in der Spalte ""PRICAT Codeverwendung"" ein X haben + [942] Format: n1-n2-n1-n3" + 67,Positionsdaten,SG36,LIN,7143,00015,Z09,,Artikel-ID,X, + 68,Preisangaben,SG40,,,,,,,Muss [22],"[22] Wenn die Artikel-ID aus dieser SG36 LIN DE7140 in der EDI@Energy Codeliste der Artikelnummern und Artikel-ID in der Spalte ""PRICAT Preisangabe"" ein X hat" + 69,Preisangaben,SG40,PRI,,00018,,,,Muss, + 70,Preisangaben,SG40,PRI,5125,00018,CAL,,Berechnungspreis,X, + 71,Preisangaben,SG40,PRI,5118,00018,,,"Preis, Betrag",X ([946] [513]) ∧ (([968][48]) ⊻ ([902] [49])),"[48] Wenn in dieser SG36 LIN in DE7140 einer der Codes 1-01-6- 005 / 1-01-9-001 / 1-01-9-002 / 1-02-0-015 / 1-03-8-001 / 1-03- 8-002 / 1-03-8-003 / 1-03-8-004 / 1-03-9-001 / 1-03-9-002 / 1-03- 9-003 / 1-03-9-004 / 1-07-4-001 vorhanden + [49] Wenn in dieser SG36 LIN in DE7140 keiner der Codes 1-01-6- 005 / 1-01-9-001 / 1-01-9-002 /" + 72,Netzbetreiberindividuelle Artikel-ID,SG17,,,,,,,Muss [9] ∧ [26],"[9] Wenn BGM DE1373 =11 nicht vorhanden + [26] Wenn BGM DE1001 = Z70 vorhanden" + 73,Netzbetreiberindividuelle Artikel-ID,SG17,PGI,,00020,,,,Muss, + 74,Netzbetreiberindividuelle Artikel-ID,SG17,PGI,5379,00020,Artikel-ID,,,Z01, + 75,Positionsdaten,SG36,,,,,,,Muss, + 76,Positionsdaten,SG36,LIN,,00021,,,,Muss, + 77,Positionsdaten,SG36,LIN,1082,00021,,,Positionsnummer,X [911],"[911] Format: Mögliche Werte: 1 bis n, je Nachricht oder Segmentgruppe bei 1 beginnend und fortlaufend aufsteigend" + 78,Positionsdaten,SG36,LIN,7140,00021,,,Produkt-/Leistungsnummer,X ([948] ⊻ [949] ⊻ [957]) ∧[42],"[42] Es sind nur Werte erlaubt, die die Bildungsvorschrift der EDI@Energy Codeliste der Artikelnummern und Artikel-ID erfüllen, und die in der Spalte ""PRICAT Codeverwendung"" ein X haben + [948] Format: n1-n2-n1-n8-n2 + [949] Format: n1-n2-n1-n8-n2-n1 + [957] Format: n1-n2-n1-n8" + 79,Positionsdaten,SG36,LIN,7143,00021,Z09,,Artikel-ID,X, + 80,Preisangaben,SG40,,,,,,,Muss, + 81,Preisangaben,SG40,PRI,,00022,,,,Muss, + 82,Preisangaben,SG40,PRI,5125,00022,CAL,,Berechnungspreis,X, + 83,Preisangaben,SG40,PRI,5118,00022,,,"Preis, Betrag",X [946],[946] Format: max. 11 Nachkommastellen + 84,Zonenintervallgrenzen,SG40,RNG,,00023,,,,Muss [24],[24] Wenn in dieser SG36 Wert von LIN DE7140 im Format n1- n2-n1-n8-n2-n1 + 85,Zonenintervallgrenzen,SG40,RNG,6167,00023,,,,10, + 86,Zonenintervallgrenzen,SG40,RNG,6411,00023,KWH,,kilowatt hour,X, + 87,Zonenintervallgrenzen,SG40,RNG,6162,00023,,,"Wertebereichsgrenze, untere",X ([926] [28] ⊻ [908] [29]),[28] Wenn die zugehörige Artikel- + 88,Zonenintervallgrenzen,SG40,RNG,6152,00023,,,"Wertebereichsgrenze, obere",S [10] ∧ [512] ,"[10] Wenn eine weitere Zone für diese Gruppenartikel-ID vorhanden + [512] Hinweis: Der genannte Wert gehört zum Intervall" + 89,Nachrichten-Endesegment,,UNT,,00024,,,,Muss, + 90,Nachrichten-Endesegment,,UNT,0074,00024,,,Anzahl der Segmente in einerNachricht,X, + 91,Nachrichten-Endesegment,,UNT,0062,00024,,,Nachrichten-Referenznummer,X, + + ''' +# --- +# name: TestCli.test_kohlrahbi_cli_with_valid_arguments[29001] + ''' + ,Segmentname,Segmentgruppe,Segment,Datenelement,Segment ID,Code,Qualifier,Beschreibung,Bedingungsausdruck,Bedingung + 0,Nachrichten-Kopfsegment,,UNH,,,,,,Muss, + 1,Nachrichten-Kopfsegment,,UNH,0062,,,,Nachrichten-Referenznummer,X, + 2,Nachrichten-Kopfsegment,,UNH,0065,,COMDIS,,Handelsunstimmigkeit,X, + 3,Nachrichten-Kopfsegment,,UNH,0052,,D,,Entwurfs-Version,X, + 4,Nachrichten-Kopfsegment,,UNH,0054,,17A,,Ausgabe 2017 - A,X, + 5,Nachrichten-Kopfsegment,,UNH,0051,,UN,,UN/CEFACT,X, + 6,Nachrichten-Kopfsegment,,UNH,0057,,1.0d,,Versionsnummer derzugrundeliegendenBDEW-Nachrichtenbeschreibung,X, + 7,Beginn der Nachricht,,BGM,,,,,,Muss, + 8,Beginn der Nachricht,,BGM,1001,,456,,Belastungsanzeige,X, + 9,Beginn der Nachricht,,BGM,1001,,739,,"MSCONS, die eineINVOIC unterstützt",, + 10,Beginn der Nachricht,,BGM,1004,,,,Dokumentennummer,X, + 11,Prüfidentifikator,,RFF,,,,,,Muss, + 12,Prüfidentifikator,,RFF,1153,,Z13,,Prüfidentifikator,X, + 13,Prüfidentifikator,,RFF,1154,,29001,,Ablehnung REMADV,X, + 14,Prüfidentifikator,,RFF,1154,,29002,,Ablehnung IFTSTA,, + 15,Dokumentendatum,,DTM,,,,,,Muss, + 16,Dokumentendatum,,DTM,2005,,137,,Dokumenten-/Nachrichtendatum/-zeit,X, + 17,Dokumentendatum,,DTM,2380,,,,"Datum oder Uhrzeit oderZeitspanne, Wert",X [931],[931] Format: ZZZ = +00 + 18,Dokumentendatum,,DTM,2379,,303,,CCYYMMDDHHMMZZZ,X, + 19,Währungsangaben,,CUX,,,,,,Muss, + 20,Währungsangaben,,CUX,6347,,2,,Referenzwährung,X, + 21,Währungsangaben,,CUX,6345,,EUR,,Euro,X, + 22,Währungsangaben,,CUX,6343,,4,,Währung der Rechnung,X, + 23,MP-ID Absender,SG1,,,,,,,Muss, + 24,MP-ID Absender,SG1,NAD,,,,,,Muss, + 25,MP-ID Absender,SG1,NAD,3035,,,,"Beteiligter, Qualifier",, + 26,MP-ID Absender,SG1,NAD,3035,,MS,,Dokumenten-/Nachrichtenausstellerbzw. -absender,X, + 27,MP-ID Absender,SG1,NAD,3039,,,,MP-ID,X,[3] Nur MP-ID aus Sparte Strom + 28,MP-ID Absender,SG1,NAD,3055,,9,,GS1,X, + 29,MP-ID Absender,SG1,NAD,3055,,293,,"DE, BDEW(Bundesverband der",X, + 30,Ansprechpartner,SG1,CTA,,,,,,Muss, + 31,Ansprechpartner,SG1,CTA,3139,,,,"Funktion des Ansprechpartners,Code",, + 32,Ansprechpartner,SG1,CTA,3139,,IC,,Informationsstelle,X, + 33,Ansprechpartner,SG1,CTA,3412,,,,Abteilung oder Bearbeiter,X, + 34,Kommunikationsverbindung,SG1,COM,,,,,,Muss, + 35,Kommunikationsverbindung,SG1,COM,3148,,,,"Kommunikationsadresse,Identifikation",X (([939][21]) ∨([940][22])) ∧[508],"[21] wenn im DE3155 in demselben COM der Code EM vorhanden ist + [22] wenn im DE3155 in demselben COM der Code TE / FX / AJ / AL vorhanden ist + [508] Hinweis: Es darf nur eine Information im DE3148 übermittelt werden + [939] Format: Die Zeichenkette muss die Zeichen @ und . enthalten + [940] Format: Die Zeichenkette muss mit dem Zeichen + beginnen und danach dürfen nur noch Ziffern folgen" + 36,Kommunikationsverbindung,SG1,COM,3155,,EM,,E-Mail,X [1P0..1], + 37,Kommunikationsverbindung,SG1,COM,3155,,FX,,Telefax,X [1P0..1], + 38,Kommunikationsverbindung,SG1,COM,3155,,TE,,Telefon,X [1P0..1], + 39,Kommunikationsverbindung,SG1,COM,3155,,AJ,,weiteres Telefon,X [1P0..1], + 40,Kommunikationsverbindung,SG1,COM,3155,,AL,,Handy,X [1P0..1], + 41,MP-ID Empfänger,SG1,,,,,,,Muss, + 42,MP-ID Empfänger,SG1,NAD,,,,,,Muss, + 43,MP-ID Empfänger,SG1,NAD,3035,,,,"Beteiligter, Qualifier",, + 44,MP-ID Empfänger,SG1,NAD,3035,,MR,,Nachrichtenempfänger,X, + 45,MP-ID Empfänger,SG1,NAD,3039,,,,MP-ID,X,[3] Nur MP-ID aus Sparte Strom + 46,MP-ID Empfänger,SG1,NAD,3055,,9,,GS1,X, + 47,MP-ID Empfänger,SG1,NAD,3055,,293,,"DE, BDEW(Bundesverband derEnergie- undWasserwirtschaft e.V.)",X, + 48,MP-ID Empfänger,SG1,NAD,3055,,332,,"DE, DVGW Service &Consult GmbH",X, + 49,Dokument-/Nachricht- Einzelheiten,SG2,,,,,,,Muss, + 50,Dokument-/Nachricht- Einzelheiten,SG2,DOC,,,,,,Muss, + 51,Dokument-/Nachricht- Einzelheiten,SG2,DOC,1001,,380,,Handelsrechnung,X, + 52,Dokument-/Nachricht- Einzelheiten,SG2,DOC,1001,,Z41,,Lieferschein Grund- /Arbeitspreis,, + 53,Dokument-/Nachricht- Einzelheiten,SG2,DOC,1001,,Z42,,Lieferschein Arbeits- /Leistungspreis,, + 54,Dokument-/Nachricht- Einzelheiten,SG2,DOC,1004,,,,Dokumentennummer,X [505],"[505] Hinweis: BGM DE1004 aus der vorher per REMADV abgelehnten INVOIC-Nachricht + [506] Hinweis: BGM DE1004 aus der vorher per IFTSTA abgelehnten MSCONS- Nachricht" + 55,angeforderter Betrag,SG2,MOA,,,,,,Muss, + 56,angeforderter Betrag,SG2,MOA,5025,,9,,Fälliger Betrag (inkl. USt.),X, + 57,angeforderter Betrag,SG2,MOA,5004,,,,Geldbetrag,X [930],[930] Format: max. 2 Nachkommastellen + 58,Begründung der Korrektheit,SG3,,,,,,,Muss, + 59,Begründung der Korrektheit,SG3,AJT,,,,,,Muss, + 60,Begründung der Korrektheit,SG3,AJT,4465,,,,"Anpassungsgrund, Code",X, + 61,Begründung der Korrektheit,SG3,AJT,1082,,,,Positionsnummer,, + 62,Begründung der Korrektheit,SG3,AJT,1082,,E_0265,,EBD Nr. E_0265,X [492] ∧ [23] ∧[24], + 63,Begründung der Korrektheit,SG3,AJT,1082,,E_0504,,EBD Nr. E_0504,X [492] ∧ [27] ∧[25], + 64,Begründung der Korrektheit,SG3,AJT,1082,,E_0516,,EBD Nr. E_0516,X [492] ∧ [23] ∧[26], + 65,Begründung der Korrektheit,SG3,AJT,1082,,E_0520,,EBD Nr. E_0520,X [492] ∧ [23] ∧[25], + 66,Begründung der Korrektheit,SG3,AJT,1082,,E_0567,,EBD Nr. E_0567,X [492] ∧ [23] ∧[26], + 67,Begründung der Korrektheit,SG3,AJT,1082,,E_1008S_0108S_0109,,EBD Nr. E_1008Codeliste Strom Nr.S_0108Codeliste Strom Nr.,X [493] ∧ [27] ∧[25]X [492] ∧ [27] ∧S_0109,"[23] Wenn MP-ID in NAD+MS (Nachrichtensender) mit Rolle MSB vorhanden + [24] Wenn MP-ID in NAD+MR (Nachrichtenempfänger) mit Rolle ESA vorhanden + [25] Wenn MP-ID in NAD+MR (Nachrichtenempfänger) mit Rolle LF vorhanden + [26] Wenn MP-ID in NAD+MR (Nachrichtenempfänger) mit Rolle NB vorhanden + [27] Wenn MP-ID in NAD+MS (Nachrichtensender) mit Rolle NB vorhanden + [492] Wenn MP-ID in NAD+MR (Nachrichtenempfänger) aus Sparte Strom + [493] Wenn MP-ID in NAD+MR (Nachrichtenempfänger) aus Sparte Gas" + 68,Begründung Richtigkeit mit Angabe einer Nachrichtenreferenz,SG3,FTX,,,,,,Muss [4] ⊻ [5] ⊻[20],[4] wenn SG3 AJT+Z58/Z59/ Z60/Z61/Z62+S_0109 + 69,Begründung Richtigkeit mit Angabe einer Nachrichtenreferenz,SG3,FTX,4451,,ACD,,Begründung,X, + 70,Begründung Richtigkeit mit Angabe einer Nachrichtenreferenz,SG3,FTX,4441,,,,Nachrichtentyp,, + 71,Begründung Richtigkeit mit Angabe einer Nachrichtenreferenz,SG3,FTX,4441,,Z07,,MSCONS,X [1], + 72,Begründung Richtigkeit mit Angabe einer Nachrichtenreferenz,SG3,FTX,4441,,Z08,,UTILMD,X [2], + 73,Begründung Richtigkeit mit Angabe einer Nachrichtenreferenz,SG3,FTX,4441,,Z09,,INVOIC,X [6] ⊻ [13], + 74,Begründung Richtigkeit mit Angabe einer Nachrichtenreferenz,SG3,FTX,4441,,Z10,,ORDERS,X [7] ⊻ [14], + 75,Begründung Richtigkeit mit Angabe einer Nachrichtenreferenz,SG3,FTX,4441,,Z11,,PRICAT,X [8] ⊻ [15], + 76,Begründung Richtigkeit mit Angabe einer Nachrichtenreferenz,SG3,FTX,4441,,Z12,,IFTSTA,X [10] ⊻ [16], + 77,Begründung Richtigkeit mit Angabe einer Nachrichtenreferenz,SG3,FTX,4441,,Z13,,ORDCHG,X [11] ⊻ [17],"[1] wenn SG3 AJT+Z61+S_0109 oder SG3 AJT+Z62+S_0109 vorhanden. + [2] wenn SG3 AJT+Z58+S_0109 oder SG3 AJT+Z59+S_0109 oder SG3 AJT+Z60+S_0109 vorhanden. + [6] wenn SG3 AJT+A07+E_0504 vorhanden + [7] wenn SG3 AJT+A02+E_0504 vorhanden + [8] wenn SG3 AJT+A01/A04/ A06/A09/A12+E_0504 vorhanden + [10] wenn SG3 AJT+A03+E_0504 vorhanden + [11] wenn SG3 AJT+A15+E_0504 vorhanden + [13] wenn SG3 AJT+A07+E_1008 vorhanden + [14] wenn SG3 AJT+A02+E_1008 vorhanden + [15] wenn SG3 AJT+A01/ A04/A06/A09+E_1008 vorhanden + [16] wenn SG3 AJT+A03+E_1008 vorhanden + [17] wenn SG3 AJT+A15+E_1008 vorhanden" + 78,Begründung Richtigkeit mit Angabe einer Nachrichtenreferenz,SG3,FTX,4440,,,,Datenaustauschreferenz derreferenzierten Datei,X, + 79,Begründung Richtigkeit mit Angabe einer Nachrichtenreferenz,SG3,FTX,4440,,,,Nachrichten-/Vorgangsnummer,X, + 80,Begründung Richtigkeit mit Angabe einer Nachrichtenreferenz,SG3,FTX,4440,,,,Datenaustauschreferenz derEmpfangsbestätigung,X, + 81,Begründung Richtigkeit mit Angabe von Freitext,SG3,FTX,,,,,,Muss [9] ⊻ [12] ⊻[18] ⊻ [19],"[9] wenn SG3 AJT+A05/A10/ A11/A14+E_0504 vorhanden + [12] wenn SG3 AJT+A99+S_0109 vorhanden + [18] wenn SG3 AJT+A05/ A10/A11+E_1008 vorhanden + [19] wenn SG3 AJT+A99+E_0265/E_0516/ E_0520/E_0567 vorhanden" + 82,Begründung Richtigkeit mit Angabe von Freitext,SG3,FTX,4451,,ACB,,ZusätzlicheInformationen (fürallgemeine Hinweise),X, + 83,Begründung Richtigkeit mit Angabe von Freitext,SG3,FTX,4440,,,,Freier Text,X, + 84,Nachrichten-Endesegment,,UNT,,,,,,Muss, + 85,Nachrichten-Endesegment,,UNT,0074,,,,Anzahl der Segmente in einerNachricht,X, + 86,Nachrichten-Endesegment,,UNT,0062,,,,Nachrichten-Referenznummer,X, + + ''' +# --- +# name: TestCli.test_kohlrahbi_cli_with_valid_arguments[29002] + ''' + ,Segmentname,Segmentgruppe,Segment,Datenelement,Segment ID,Code,Qualifier,Beschreibung,Bedingungsausdruck,Bedingung + 0,Nachrichten-Kopfsegment,,UNH,,,,,,Muss, + 1,Nachrichten-Kopfsegment,,UNH,0062,,,,Nachrichten-Referenznummer,X, + 2,Nachrichten-Kopfsegment,,UNH,0065,,COMDIS,,Handelsunstimmigkeit,X, + 3,Nachrichten-Kopfsegment,,UNH,0052,,D,,Entwurfs-Version,X, + 4,Nachrichten-Kopfsegment,,UNH,0054,,17A,,Ausgabe 2017 - A,X, + 5,Nachrichten-Kopfsegment,,UNH,0051,,UN,,UN/CEFACT,X, + 6,Nachrichten-Kopfsegment,,UNH,0057,,1.0d,,Versionsnummer derzugrundeliegendenBDEW-Nachrichtenbeschreibung,X, + 7,Beginn der Nachricht,,BGM,,,,,,Muss, + 8,Beginn der Nachricht,,BGM,1001,,456,,Belastungsanzeige,, + 9,Beginn der Nachricht,,BGM,1001,,739,,"MSCONS, die eineINVOIC unterstützt",X, + 10,Beginn der Nachricht,,BGM,1004,,,,Dokumentennummer,X, + 11,Prüfidentifikator,,RFF,,,,,,Muss, + 12,Prüfidentifikator,,RFF,1153,,Z13,,Prüfidentifikator,X, + 13,Prüfidentifikator,,RFF,1154,,29001,,Ablehnung REMADV,, + 14,Prüfidentifikator,,RFF,1154,,29002,,Ablehnung IFTSTA,X, + 15,Dokumentendatum,,DTM,,,,,,Muss, + 16,Dokumentendatum,,DTM,2005,,137,,Dokumenten-/Nachrichtendatum/-zeit,X, + 17,Dokumentendatum,,DTM,2380,,,,"Datum oder Uhrzeit oderZeitspanne, Wert",X [931],[931] Format: ZZZ = +00 + 18,Dokumentendatum,,DTM,2379,,303,,CCYYMMDDHHMMZZZ,X, + 19,Währungsangaben,,CUX,,,,,,, + 20,Währungsangaben,,CUX,6347,,2,,Referenzwährung,, + 21,Währungsangaben,,CUX,6345,,EUR,,Euro,, + 22,Währungsangaben,,CUX,6343,,4,,Währung der Rechnung,, + 23,MP-ID Absender,SG1,,,,,,,Muss, + 24,MP-ID Absender,SG1,NAD,,,,,,Muss, + 25,MP-ID Absender,SG1,NAD,3035,,,,"Beteiligter, Qualifier",, + 26,MP-ID Absender,SG1,NAD,3035,,MS,,Dokumenten-/Nachrichtenausstellerbzw. -absender,X, + 27,MP-ID Absender,SG1,NAD,3039,,,,MP-ID,X [3],[3] Nur MP-ID aus Sparte Strom + 28,MP-ID Absender,SG1,NAD,3055,,9,,GS1,X, + 29,MP-ID Absender,SG1,NAD,3055,,293,,"DE, BDEW(Bundesverband der",X, + 30,Ansprechpartner,SG1,CTA,,,,,,Muss, + 31,Ansprechpartner,SG1,CTA,3139,,,,"Funktion des Ansprechpartners,Code",, + 32,Ansprechpartner,SG1,CTA,3139,,IC,,Informationsstelle,X, + 33,Ansprechpartner,SG1,CTA,3412,,,,Abteilung oder Bearbeiter,X, + 34,Kommunikationsverbindung,SG1,COM,,,,,,Muss, + 35,Kommunikationsverbindung,SG1,COM,3148,,,,"Kommunikationsadresse,Identifikation",X (([939][21]) ∨([940][22])) ∧[508],"[21] wenn im DE3155 in demselben COM der Code EM vorhanden ist + [22] wenn im DE3155 in demselben COM der Code TE / FX / AJ / AL vorhanden ist + [508] Hinweis: Es darf nur eine Information im DE3148 übermittelt werden + [939] Format: Die Zeichenkette muss die Zeichen @ und . enthalten + [940] Format: Die Zeichenkette muss mit dem Zeichen + beginnen und danach dürfen nur noch Ziffern folgen" + 36,Kommunikationsverbindung,SG1,COM,3155,,EM,,E-Mail,X [1P0..1], + 37,Kommunikationsverbindung,SG1,COM,3155,,FX,,Telefax,X [1P0..1], + 38,Kommunikationsverbindung,SG1,COM,3155,,TE,,Telefon,X [1P0..1], + 39,Kommunikationsverbindung,SG1,COM,3155,,AJ,,weiteres Telefon,X [1P0..1], + 40,Kommunikationsverbindung,SG1,COM,3155,,AL,,Handy,X [1P0..1], + 41,MP-ID Empfänger,SG1,,,,,,,Muss, + 42,MP-ID Empfänger,SG1,NAD,,,,,,Muss, + 43,MP-ID Empfänger,SG1,NAD,3035,,,,"Beteiligter, Qualifier",, + 44,MP-ID Empfänger,SG1,NAD,3035,,MR,,Nachrichtenempfänger,X, + 45,MP-ID Empfänger,SG1,NAD,3039,,,,MP-ID,X [3],[3] Nur MP-ID aus Sparte Strom + 46,MP-ID Empfänger,SG1,NAD,3055,,9,,GS1,X, + 47,MP-ID Empfänger,SG1,NAD,3055,,293,,"DE, BDEW(Bundesverband derEnergie- undWasserwirtschaft e.V.)",X, + 48,MP-ID Empfänger,SG1,NAD,3055,,332,,"DE, DVGW Service &Consult GmbH",, + 49,Dokument-/Nachricht- Einzelheiten,SG2,,,,,,,Muss, + 50,Dokument-/Nachricht- Einzelheiten,SG2,DOC,,,,,,Muss, + 51,Dokument-/Nachricht- Einzelheiten,SG2,DOC,1001,,380,,Handelsrechnung,, + 52,Dokument-/Nachricht- Einzelheiten,SG2,DOC,1001,,Z41,,Lieferschein Grund- /Arbeitspreis,X, + 53,Dokument-/Nachricht- Einzelheiten,SG2,DOC,1001,,Z42,,Lieferschein Arbeits- /Leistungspreis,X, + 54,Dokument-/Nachricht- Einzelheiten,SG2,DOC,1004,,,,Dokumentennummer,X [506],"[505] Hinweis: BGM DE1004 aus der vorher per REMADV abgelehnten INVOIC-Nachricht + [506] Hinweis: BGM DE1004 aus der vorher per IFTSTA abgelehnten MSCONS- Nachricht" + 55,angeforderter Betrag,SG2,MOA,,,,,,, + 56,angeforderter Betrag,SG2,MOA,5025,,9,,Fälliger Betrag (inkl. USt.),, + 57,angeforderter Betrag,SG2,MOA,5004,,,,Geldbetrag,,[930] Format: max. 2 Nachkommastellen + 58,Begründung der Korrektheit,SG3,,,,,,,Muss, + 59,Begründung der Korrektheit,SG3,AJT,,,,,,Muss, + 60,Begründung der Korrektheit,SG3,AJT,4465,,,,"Anpassungsgrund, Code",X, + 61,Begründung der Korrektheit,SG3,AJT,1082,,,,Positionsnummer,, + 62,Begründung der Korrektheit,SG3,AJT,1082,,E_0265,,EBD Nr. E_0265,, + 63,Begründung der Korrektheit,SG3,AJT,1082,,E_0504,,EBD Nr. E_0504,, + 64,Begründung der Korrektheit,SG3,AJT,1082,,E_0516,,EBD Nr. E_0516,, + 65,Begründung der Korrektheit,SG3,AJT,1082,,E_0520,,EBD Nr. E_0520,, + 66,Begründung der Korrektheit,SG3,AJT,1082,,E_0567,,EBD Nr. E_0567,, + 67,Begründung der Korrektheit,SG3,AJT,1082,,E_1008S_0108S_0109,,EBD Nr. E_1008Codeliste Strom Nr.S_0108Codeliste Strom Nr.,X [492],"[23] Wenn MP-ID in NAD+MS (Nachrichtensender) mit Rolle MSB vorhanden + [24] Wenn MP-ID in NAD+MR (Nachrichtenempfänger) mit Rolle ESA vorhanden + [25] Wenn MP-ID in NAD+MR (Nachrichtenempfänger) mit Rolle LF vorhanden + [26] Wenn MP-ID in NAD+MR (Nachrichtenempfänger) mit Rolle NB vorhanden + [27] Wenn MP-ID in NAD+MS (Nachrichtensender) mit Rolle NB vorhanden + [492] Wenn MP-ID in NAD+MR (Nachrichtenempfänger) aus Sparte Strom + [493] Wenn MP-ID in NAD+MR (Nachrichtenempfänger) aus Sparte Gas" + 68,Begründung Richtigkeit mit Angabe einer Nachrichtenreferenz,SG3,FTX,,,,,,,[4] wenn SG3 AJT+Z58/Z59/ Z60/Z61/Z62+S_0109 + 69,Begründung Richtigkeit mit Angabe einer Nachrichtenreferenz,SG3,FTX,4451,,ACD,,Begründung,, + 70,Begründung Richtigkeit mit Angabe einer Nachrichtenreferenz,SG3,FTX,4441,,,,Nachrichtentyp,, + 71,Begründung Richtigkeit mit Angabe einer Nachrichtenreferenz,SG3,FTX,4441,,Z07,,MSCONS,, + 72,Begründung Richtigkeit mit Angabe einer Nachrichtenreferenz,SG3,FTX,4441,,Z08,,UTILMD,, + 73,Begründung Richtigkeit mit Angabe einer Nachrichtenreferenz,SG3,FTX,4441,,Z09,,INVOIC,, + 74,Begründung Richtigkeit mit Angabe einer Nachrichtenreferenz,SG3,FTX,4441,,Z10,,ORDERS,, + 75,Begründung Richtigkeit mit Angabe einer Nachrichtenreferenz,SG3,FTX,4441,,Z11,,PRICAT,, + 76,Begründung Richtigkeit mit Angabe einer Nachrichtenreferenz,SG3,FTX,4441,,Z12,,IFTSTA,, + 77,Begründung Richtigkeit mit Angabe einer Nachrichtenreferenz,SG3,FTX,4441,,Z13,,ORDCHG,,"[1] wenn SG3 AJT+Z61+S_0109 oder SG3 AJT+Z62+S_0109 vorhanden. + [2] wenn SG3 AJT+Z58+S_0109 oder SG3 AJT+Z59+S_0109 oder SG3 AJT+Z60+S_0109 vorhanden. + [6] wenn SG3 AJT+A07+E_0504 vorhanden + [7] wenn SG3 AJT+A02+E_0504 vorhanden + [8] wenn SG3 AJT+A01/A04/ A06/A09/A12+E_0504 vorhanden + [10] wenn SG3 AJT+A03+E_0504 vorhanden + [11] wenn SG3 AJT+A15+E_0504 vorhanden + [13] wenn SG3 AJT+A07+E_1008 vorhanden + [14] wenn SG3 AJT+A02+E_1008 vorhanden + [15] wenn SG3 AJT+A01/ A04/A06/A09+E_1008 vorhanden + [16] wenn SG3 AJT+A03+E_1008 vorhanden + [17] wenn SG3 AJT+A15+E_1008 vorhanden" + 78,Begründung Richtigkeit mit Angabe einer Nachrichtenreferenz,SG3,FTX,4440,,,,Datenaustauschreferenz derreferenzierten Datei,, + 79,Begründung Richtigkeit mit Angabe einer Nachrichtenreferenz,SG3,FTX,4440,,,,Nachrichten-/Vorgangsnummer,, + 80,Begründung Richtigkeit mit Angabe einer Nachrichtenreferenz,SG3,FTX,4440,,,,Datenaustauschreferenz derEmpfangsbestätigung,, + 81,Begründung Richtigkeit mit Angabe von Freitext,SG3,FTX,,,,,,Muss,"[9] wenn SG3 AJT+A05/A10/ A11/A14+E_0504 vorhanden + [12] wenn SG3 AJT+A99+S_0109 vorhanden + [18] wenn SG3 AJT+A05/ A10/A11+E_1008 vorhanden + [19] wenn SG3 AJT+A99+E_0265/E_0516/ E_0520/E_0567 vorhanden" + 82,Begründung Richtigkeit mit Angabe von Freitext,SG3,FTX,4451,,ACB,,ZusätzlicheInformationen (fürallgemeine Hinweise),X, + 83,Begründung Richtigkeit mit Angabe von Freitext,SG3,FTX,4440,,,,Freier Text,X, + 84,Nachrichten-Endesegment,,UNT,,,,,,Muss, + 85,Nachrichten-Endesegment,,UNT,0074,,,,Anzahl der Segmente in einerNachricht,X, + 86,Nachrichten-Endesegment,,UNT,0062,,,,Nachrichten-Referenznummer,X, + + ''' +# --- +# name: TestCli.test_kohlrahbi_cli_with_valid_arguments[31001] + ''' + ,Segmentname,Segmentgruppe,Segment,Datenelement,Segment ID,Code,Qualifier,Beschreibung,Bedingungsausdruck,Bedingung + 0,Nachrichtenanfang,,UNH,,,,,,Muss, + 1,Nachrichtenanfang,,UNH,0062,,,,Nachrichten-Referenznummer,X, + 2,Nachrichtenanfang,,UNH,0065,,INVOIC,,Rechnung,X, + 3,Nachrichtenanfang,,UNH,0052,,D,,Entwurfs-Version,X, + 4,Nachrichtenanfang,,UNH,0054,,06A,,Ausgabe 2006 - A,X, + 5,Nachrichtenanfang,,UNH,0051,,UN,,UN/CEFACT,X, + 6,Nachrichtenanfang,,UNH,0057,,2.8c,,VersionsnummerderzugrundeliegendenBDEW-Nachrichtenbeschreibung,X, + 7,Rechnungsnummer,,BGM,,,,,,Muss, + 8,Rechnungsnummer,,BGM,1001,,380,,Handelsrechnung,X, + 9,Rechnungsnummer,,BGM,1004,,,,Dokumentennummer,X, + 10,Rechnungsnummer,,BGM,1225,,7,,Duplikat,X, + 11,Rechnungsnummer,,BGM,1225,,9,,Original,X, + 12,Nachrichtendatum,,DTM,,,,,,Muss, + 13,Nachrichtendatum,,DTM,2005,,137,,Dokumenten-/Nachrichtendatum/-zeit,X, + 14,Nachrichtendatum,,DTM,2380,,,,"Datum oder Uhrzeit oderZeitspanne, Wert",X [931],[931] Format: ZZZ = +00 + 15,Nachrichtendatum,,DTM,2379,,303,,CCYYMMDDHHMMZZZ,X, + 16,Bearbeitungs-/ Verarbeitungsdatum,,DTM,,,,,,Muss, + 17,Bearbeitungs-/ Verarbeitungsdatum,,DTM,2005,,9,,Bearbeitungs-/Verarbeitungsdatum/-zeit,X, + 18,Bearbeitungs-/ Verarbeitungsdatum,,DTM,2380,,,,"Datum oder Uhrzeit oderZeitspanne, Wert",X [931],[931] Format: ZZZ = +00 + 19,Bearbeitungs-/ Verarbeitungsdatum,,DTM,2379,,303,,CCYYMMDDHHMMZZZ,X, + 20,Abrechnungszeitraum Beginn,,DTM,,,,,,,[2] Wenn es sich um eine Nutzungsüberlassung (Pacht) eines Gerätes handelt + 21,Abrechnungszeitraum Beginn,,DTM,2005,,155,,"Rechnungsperiode,Beginndatum",, + 22,Abrechnungszeitraum Beginn,,DTM,2380,,,,"Datum oder Uhrzeit oderZeitspanne, Wert",, + 23,Abrechnungszeitraum Beginn,,DTM,2379,,303,,CCYYMMDDHHMMZZZ,, + 24,Abrechnungszeitraum Ende,,DTM,,,,,,,[2] Wenn es sich um eine Nutzungsüberlassung (Pacht) eines Gerätes handelt + 25,Abrechnungszeitraum Ende,,DTM,2005,,156,,"Rechnungsperiode,Endedatum",, + 26,Abrechnungszeitraum Ende,,DTM,2380,,,,"Datum oder Uhrzeit oderZeitspanne, Wert",, + 27,Abrechnungszeitraum Ende,,DTM,2379,,303,,CCYYMMDDHHMMZZZ,, + 28,vorläufiger Abrechnungszeitraum Beginn,,DTM,,,,,,Muss, + 29,vorläufiger Abrechnungszeitraum Beginn,,DTM,2005,,Z42,,vorläufigerAbrechnungszeitraum Beginn,X, + 30,vorläufiger Abrechnungszeitraum Beginn,,DTM,2380,,,,"Datum oder Uhrzeit oderZeitspanne, Wert",X [UB3], + 31,vorläufiger Abrechnungszeitraum Beginn,,DTM,2379,,303,,CCYYMMDDHHMMZZZ,X, + 32,vorläufiger Abrechnungszeitraum Ende,,DTM,,,,,,Muss, + 33,vorläufiger Abrechnungszeitraum Ende,,DTM,2005,,Z43,,vorläufigerAbrechnungszeitraum Ende,X, + 34,vorläufiger Abrechnungszeitraum Ende,,DTM,2380,,,,"Datum oder Uhrzeit oderZeitspanne, Wert",X [UB3], + 35,vorläufiger Abrechnungszeitraum Ende,,DTM,2379,,303,,CCYYMMDDHHMMZZZ,X, + 36,Ausführungsdatum,,DTM,,,,,,,[3] Wenn es sich um einen Kauf eines Gerätes handelt + 37,Ausführungsdatum,,DTM,2005,,203,,Ausführungsdatum/-zeit,, + 38,Ausführungsdatum,,DTM,2380,,,,"Datum oder Uhrzeit oderZeitspanne, Wert",,[931] Format: ZZZ = +00 + 39,Ausführungsdatum,,DTM,2379,,303,,CCYYMMDDHHMMZZZ,, + 40,Rechnungstyp,,IMD,,,,,,Muss, + 41,Rechnungstyp,,IMD,7081,,ABR,,Abschlussrechnung,, + 42,Rechnungstyp,,IMD,7081,,ABS,,Abschlagsrechnung,X,[56] Wenn DTM+137 (Nachrichtendatum ≥ + 43,Meldeinformationen,,FTX,,,,,,Soll [4],[4] Wenn Steuerschuldnerschaft des Leistungsempfängers vorliegt + 44,Meldeinformationen,,FTX,4451,,REG,,Meldeinformationen,X, + 45,Meldeinformationen,,FTX,4441,,RCH,,Reverse Chargegemäß §13b UStG /Steuerschuldnerschaft desLeistungsempfängers,X, + 46,Spezifikation der Sonderrechnung,,GEI,,,,,,,[41] Wenn IMD++SOR vorhanden + 47,Spezifikation der Sonderrechnung,,GEI,9649,,Z01,,Art derSonderrechnung,, + 48,Spezifikation der Sonderrechnung,,GEI,7365,,Z01,,Konzessionsabgabe(Testat),, + 49,Spezifikation der Sonderrechnung,,GEI,7365,,Z02,,IndividuelleVereinbarung füratypische undenergieintensiveNetznutzung,, + 50,Spezifikation der Sonderrechnung,,GEI,7365,,Z03,,IndividuelleVereinbarung fürsinguläreNetznutzung,,"[78] Wenn GEI+Z08 nicht vorhanden + [79] Wenn GEI+Z09 nicht vorhanden + [80] Wenn GEI+Z01 nicht vorhanden + [81] Wenn GEI+Z04 nicht vorhanden + [82] Wenn GEI+Z05 nicht vorhanden" + 51,Prüfidentifikator,SG1,,,,,,,Muss, + 52,Prüfidentifikator,SG1,RFF,,,,,,Muss, + 53,Prüfidentifikator,SG1,RFF,1153,,Z13,,Prüfidentifikator,X, + 54,Prüfidentifikator,SG1,RFF,1154,,31001,,Abschlagsrechnung,X, + 55,Prüfidentifikator,SG1,RFF,1154,,31002,,NN-Rechnung,, + 56,Prüfidentifikator,SG1,RFF,1154,,31003,,WiM-Rechnung,, + 57,Prüfidentifikator,SG1,RFF,1154,,31009,,MSB-Rechnung,, + 58,Referenz auf Ursprungsrechnungsnum mer,SG1,,,,,,,,[41] Wenn IMD++SOR vorhanden + 59,Referenz auf Ursprungsrechnungsnum mer,SG1,RFF,,,,,,, + 60,Referenz auf Ursprungsrechnungsnum mer,SG1,RFF,1153,,OI,,Ursprungsrechnungsnummer,, + 61,Referenz auf Ursprungsrechnungsnum mer,SG1,RFF,1154,,,,"Referenz, Identifikation",, + 62,Referenzdatum,SG1,DTM,,,,,,, + 63,Referenzdatum,SG1,DTM,2005,,171,,Referenzdatum/-zeit,, + 64,Referenzdatum,SG1,DTM,2380,,,,"Datum oder Uhrzeit oderZeitspanne, Wert",, + 65,Referenzdatum,SG1,DTM,2379,,303,,CCYYMMDDHHMMZZZ,, + 66,Referenz auf Nummer des zugehörigen Dokuments,SG1,,,,,,,,"[36] Wenn DTM+156 (Abrechnungszeitraum Ende) ≥ 01.12.2019 + [37] Wenn Lieferschein zuvor ausgetauscht wurde + [50] Wenn IMD++SOR nicht vorhanden + [66] Wenn IMD++KON vorhanden + [72] Wenn MP-ID in NAD+MR in der Rolle LF + [73] Wenn IMD++MSB" + 67,Referenz auf Nummer des zugehörigen Dokuments,SG1,RFF,,,,,,, + 68,Referenz auf Nummer des zugehörigen Dokuments,SG1,RFF,1153,,ACE,,Nummer deszugehörigenDokuments,, + 69,Referenz auf Nummer des zugehörigen Dokuments,SG1,RFF,1154,,,,"Referenz, Identifikation",,"[66] Wenn IMD++KON vorhanden + [73] Wenn IMD++MSB vorhanden + [501] Hinweis: Dokumentennummer der ORDERS + [508] Hinweis: Dokumentennummer der QUOTES + [514] Hinweis: Dokumentennummer der Lieferschein- MSCONS" + 70,Name und Anschrift des Nachrichtensenders,SG2,,,,,,,Muss, + 71,Name und Anschrift des Nachrichtensenders,SG2,NAD,,,,,,Muss, + 72,Name und Anschrift des Nachrichtensenders,SG2,NAD,3035,,MS,,Dokumenten-/Nachrichtenaussteller bzw. -absender,X, + 73,Name und Anschrift des Nachrichtensenders,SG2,NAD,3039,,,,MP-ID,X,[45] Nur MP-ID aus Sparte Strom + 74,Name und Anschrift des Nachrichtensenders,SG2,NAD,3055,,9,,GS1,X, + 75,Name und Anschrift des Nachrichtensenders,SG2,NAD,3055,,293,,"DE, BDEW(Bundesverband derEnergie- undWasserwirtschafte.V.)",X, + 76,Name und Anschrift des Nachrichtensenders,SG2,NAD,3055,,332,,"DE, DVGW Service &Consult GmbH",X, + 77,Name und Anschrift des Nachrichtensenders,SG2,NAD,3036,,,,Beteiligter,X, + 78,Name und Anschrift des Nachrichtensenders,SG2,NAD,3045,,Z01,,Struktur vonPersonennamen,X, + 79,Name und Anschrift des Nachrichtensenders,SG2,NAD,3045,,Z02,,Struktur derFirmenbezeichnung,X, + 80,Name und Anschrift des Nachrichtensenders,SG2,NAD,3042,,,,Straße und Hausnummeroder Postfach,S [7],[7] Sofern keine Großkundenpostleitza hl verwendet wird + 81,Name und Anschrift des Nachrichtensenders,SG2,NAD,3164,,,,Ort,M, + 82,Name und Anschrift des Nachrichtensenders,SG2,NAD,3251,,,,"Postleitzahl, Code",X, + 83,Name und Anschrift des Nachrichtensenders,SG2,NAD,3207,,,,"Ländername, Code",X, + 84,"Steuernummer, Umsatzsteuernummer",SG3,,,,,,,Muss, + 85,"Steuernummer, Umsatzsteuernummer",SG3,RFF,,,,,,Muss, + 86,"Steuernummer, Umsatzsteuernummer",SG3,RFF,1153,,VA,,Umsatzsteuernummer,X, + 87,"Steuernummer, Umsatzsteuernummer",SG3,RFF,1153,,FC,,Steuernummer,X [6],[6] Wenn NAD+MR DE3207 = „DE“ + 88,"Steuernummer, Umsatzsteuernummer",SG3,RFF,1154,,,,"Referenz, Identifikation",X, + 89,Ansprechpartner,SG5,,,,,,,Kann, + 90,Ansprechpartner,SG5,CTA,,,,,,Muss, + 91,Ansprechpartner,SG5,CTA,3139,,IC,,Informationskontakt,X, + 92,Ansprechpartner,SG5,CTA,3412,,,,Kontakt,X, + 93,Kommunikationsverbindu ng,SG5,COM,,,,,,Muss, + 94,Kommunikationsverbindu ng,SG5,COM,3148,,,,"Kommunikationsadresse,Identifikation",X (([939][74]) ∨([940][75]))∧ [524],"[74] wenn im DE3155 in demselben COM der Code EM vorhanden ist + [75] wenn im DE3155 in demselben COM der Code TE / FX / AJ / AL vorhanden ist + [524] Hinweis: Es darf nur eine Information im DE3148 übermittelt werden + [939] Format: Die Zeichenkette muss die Zeichen @ und . enthalten + [940] Format: Die Zeichenkette muss mit dem Zeichen + beginnen und danach dürfen nur noch Ziffern folgen" + 95,Kommunikationsverbindu ng,SG5,COM,3155,,EM,,Elektronische Post,X [1P0..1], + 96,Kommunikationsverbindu ng,SG5,COM,3155,,FX,,Telefax,X [1P0..1], + 97,Kommunikationsverbindu ng,SG5,COM,3155,,TE,,Telefon,X [1P0..1], + 98,Name und Anschrift des Nachrichtenempfängers,SG2,,,,,,,Muss, + 99,Name und Anschrift des Nachrichtenempfängers,SG2,NAD,,,,,,Muss, + 100,Name und Anschrift des Nachrichtenempfängers,SG2,NAD,3035,,MR,,Nachrichtenempfänger,X, + 101,Name und Anschrift des Nachrichtenempfängers,SG2,NAD,3039,,,,MP-ID,X,[45] Nur MP-ID aus Sparte Strom + 102,Name und Anschrift des Nachrichtenempfängers,SG2,NAD,3055,,9,,GS1,X, + 103,Name und Anschrift des Nachrichtenempfängers,SG2,NAD,3055,,293,,"DE, BDEW(Bundesverband derEnergie- undWasserwirtschafte.V.)",X, + 104,Name und Anschrift des Nachrichtenempfängers,SG2,NAD,3055,,332,,"DE, DVGW Service &Consult GmbH",X, + 105,Name und Anschrift des Nachrichtenempfängers,SG2,NAD,3036,,,,Beteiligter,X, + 106,Name und Anschrift des Nachrichtenempfängers,SG2,NAD,3045,,Z01,,Struktur vonPersonennamen,X, + 107,Name und Anschrift des Nachrichtenempfängers,SG2,NAD,3045,,Z02,,Struktur derFirmenbezeichnung,X, + 108,Name und Anschrift des Nachrichtenempfängers,SG2,NAD,3042,,,,Straße und Hausnummeroder Postfach,S [7],[7] Sofern keine Großkundenpostleitza hl verwendet wird + 109,Name und Anschrift des Nachrichtenempfängers,SG2,NAD,3164,,,,Ort,M, + 110,Name und Anschrift des Nachrichtenempfängers,SG2,NAD,3251,,,,"Postleitzahl, Code",X, + 111,Name und Anschrift des Nachrichtenempfängers,SG2,NAD,3207,,,,"Ländername, Code",X, + 112,"Steuernummer, Umsatzsteuernummer",SG3,,,,,,,Muss [5]Soll [4],"[4] Wenn Steuerschuldnerschaft des Leistungsempfängers vorliegt + [5] Wenn NAD+MR DE3207 <> „DE“" + 113,"Steuernummer, Umsatzsteuernummer",SG3,RFF,,,,,,Muss, + 114,"Steuernummer, Umsatzsteuernummer",SG3,RFF,1153,,VA,,Umsatzsteuernummer,X, + 115,"Steuernummer, Umsatzsteuernummer",SG3,RFF,1153,,FC,,Steuernummer,X [6],[6] Wenn NAD+MR DE3207 = „DE“ + 116,"Steuernummer, Umsatzsteuernummer",SG3,RFF,1154,,,,"Referenz, Identifikation",X, + 117,Adresse der Leistungserbringung,SG2,,,,,,,Muss, + 118,Adresse der Leistungserbringung,SG2,NAD,,,,,,Muss, + 119,Adresse der Leistungserbringung,SG2,NAD,3035,,DP,,Lieferanschrift,X, + 120,Adresse der Leistungserbringung,SG2,NAD,3124,,,,Zusatzinformation zurIdentifizierung,K, + 121,Adresse der Leistungserbringung,SG2,NAD,3042,,,,Straße und Hausnummeroder Postfach,S [22]M [23],"[22] Wenn vorhanden + [23] Wenn im selben" + 122,Adresse der Leistungserbringung,SG2,NAD,3164,,,,Ort,M, + 123,Adresse der Leistungserbringung,SG2,NAD,3251,,,,"Postleitzahl, Code",X, + 124,Adresse der Leistungserbringung,SG2,NAD,3207,,,,"Ländername, Code",X, + 125,Meldepunkt,SG2,LOC,,,,,,Muss, + 126,Meldepunkt,SG2,LOC,3227,,172,,Meldepunkt,X, + 127,Meldepunkt,SG2,LOC,3225,,,,"Ortsangabe, Nummer",X [950][509],"[509] Hinweis: Verwendung der ID der Marktlokation + [510] Hinweis: Verwendung der ID der Messlokation + [522] Hinweis: Verwendung der ID der Netzlokation + [523] Hinweis: Verwendung der ID der Steuerbaren Ressource + [950] Format: Marktlokations-ID + [951] Format: Zählpunktbezeichnung + [960] Format: Netzlokations-ID + [961] Format: SR-ID" + 128,Währungsangaben,SG7,,,,,,,Muss, + 129,Währungsangaben,SG7,CUX,,,,,,Muss, + 130,Währungsangaben,SG7,CUX,6347,,2,,Referenzwährung,X, + 131,Währungsangaben,SG7,CUX,6345,,EUR,,Euro,X, + 132,Währungsangaben,SG7,CUX,6343,,4,,Währung derRechnung,X, + 133,Zahlungsbedingungen,SG8,,,,,,,Muss, + 134,Zahlungsbedingungen,SG8,PYT,,,,,,Muss, + 135,Zahlungsbedingungen,SG8,PYT,4279,,3,,Fixdatum,X, + 136,Fälligkeitsdatum,SG8,DTM,,,,,,Muss, + 137,Fälligkeitsdatum,SG8,DTM,2005,,265,,Fälligkeitsdatum,X, + 138,Fälligkeitsdatum,SG8,DTM,2380,,,,"Datum oder Uhrzeit oderZeitspanne, Wert",X [UB1] ∧(([493] ∧[20] ∧ [24])⊻ ([493] ∧[21] ∧ [25])⊻ [492]),"[20] Wenn fälliger Betrag (SG50 MOA+9) ≥ 0 + [21] Wenn fälliger Betrag (SG50 MOA+9) < 0 + [24] Wert muss" + 139,Fälligkeitsdatum,SG8,DTM,2379,,303,,CCYYMMDDHHMMZZZ,X, + 140,Positionsdaten,SG26,,,,,,,Muss, + 141,Positionsdaten,SG26,LIN,,,,,,Muss, + 142,Positionsdaten,SG26,LIN,1082,,,,Positionsnummer,X [911],"[911] Format: Mögliche Werte: 1 bis n, je Nachricht oder Segmentgruppe bei 1 beginnend und fortlaufend aufsteigend" + 143,Positionsdaten,SG26,LIN,7140,,,,Produkt-/Leistungsnummer,X [40],"[40] Es sind nur die Artikelnummern erlaubt, die in der Codeliste der Artikelnummern und Artikel-ID mit dem entsprechenden Prüfidentifikator versehen sind oder Artikel-ID aus der Codeliste der Artikelnummern und Artikel-ID. + [41] Wenn IMD++SOR vorhanden + [50] Wenn IMD++SOR nicht vorhanden + [67] Es sind nur die Artikelnummern erlaubt, die im Kapitel 2 „Codeliste der Artikelnummer“ in der Codeliste der Artikelnummern und Artikel-ID ein „X“ für den entsprechenden Prüfidentifikator" + 144,Positionsdaten,SG26,LIN,7143,,Z01,,Artikelnummer,X, + 145,Positionsdaten,SG26,LIN,7143,,Z09,,Artikel-ID,,"[51] Wenn SG26 DTM+156 (Positionsbezogener Abrechnungszeitraum Ende) ≤ 1.1.2023 0:00 gesetzlicher deutscher Zeit + [59] Wenn SG26 DTM+155 (Positionsbezogener Abrechnungszeitraum Beginn) ≥ 1.1.2023 0: 00 gesetzlicher deutscher Zeit + [65] Wenn SG26 DTM+155 (Positionsbezogener Abrechnungszeitraum Beginn) ≥ 1.1.2024 0: 00 gesetzlicher deutscher Zeit + [66] Wenn IMD++KON vorhanden + [77] Wenn SG26 DTM+156 (Positionsbezogener Abrechnungszeitraum Ende) ≤ 1.1.2024 0:00 gesetzlicher deutscher Zeit + [492] Wenn MP-ID in NAD+MR (Nachrichtenempfäng" + 146,energetische Mengenangaben,SG26,QTY,,,,,,Muss, + 147,energetische Mengenangaben,SG26,QTY,6063,,47,,Berechnete(fakturierte) Menge,X, + 148,energetische Mengenangaben,SG26,QTY,6060,,,,Menge,X [902] ∧[906],"[902] Format: Möglicher Wert: ≥ 0 + [906] Format: max. 3 Nachkommastellen + [910] Format: Möglicher Wert: < 0 oder ≥ 0 " + 149,energetische Mengenangaben,SG26,QTY,6411,,KWH,,Kilowattstunde,, + 150,energetische Mengenangaben,SG26,QTY,6411,,KWT,,Kilowatt,, + 151,energetische Mengenangaben,SG26,QTY,6411,,KVR,,kilovar,, + 152,energetische Mengenangaben,SG26,QTY,6411,,K3,,kilovolt ampere,, + 153,energetische Mengenangaben,SG26,QTY,6411,,H87,,Stück,X,"[51] Wenn SG26 DTM+156 (Positionsbezogener Abrechnungszeitraum Ende) ≤ 1.1.2023 0:00 gesetzlicher deutscher Zeit + [492] Wenn MP-ID in NAD+MR (Nachrichtenempfäng er) aus Sparte Strom" + 154,zeitliche Mengenangaben,SG26,QTY,,,,,,,[8] Bei zeitabhängigen Preisen + 155,zeitliche Mengenangaben,SG26,QTY,6063,,136,,Erreichte Menge indem Zeitintervall,, + 156,zeitliche Mengenangaben,SG26,QTY,6060,,,,Menge,,[908] Format: Mögliche Werte: 1 bis n + 157,zeitliche Mengenangaben,SG26,QTY,6411,,DAY,,Tag,, + 158,zeitliche Mengenangaben,SG26,QTY,6411,,MON,,Monat,, + 159,zeitliche Mengenangaben,SG26,QTY,6411,,ANN,,Jahr,,"[51] Wenn SG26 DTM+156 (Positionsbezogener Abrechnungszeitraum Ende) ≤ 1.1.2023 0:00 gesetzlicher deutscher Zeit + [64] Wenn DTM+156 (Abrechnungszeitraum Ende) ≤ 1.1.2024 0:00 gesetzlicher deutscher Zeit + [493] Wenn MP-ID in NAD+MR (Nachrichtenempfäng er) aus Sparte Gas" + 160,Positionsbezogener Abrechnungszeitraum Beginn,SG26,DTM,,,,,,Muss,[9] Wenn SG26 DTM+203 nicht vorhanden + 161,Positionsbezogener Abrechnungszeitraum Beginn,SG26,DTM,2005,,155,,"Rechnungsperiode,Beginndatum",X, + 162,Positionsbezogener Abrechnungszeitraum Beginn,SG26,DTM,2380,,,,"Datum oder Uhrzeit oderZeitspanne, Wert",X [UB3], + 163,Positionsbezogener Abrechnungszeitraum Beginn,SG26,DTM,2379,,303,,CCYYMMDDHHMMZZZ,X, + 164,Positionsbezogener Abrechnungszeitraum Ende,SG26,DTM,,,,,,Muss,[9] Wenn SG26 DTM+203 nicht vorhanden + 165,Positionsbezogener Abrechnungszeitraum Ende,SG26,DTM,2005,,156,,"Rechnungsperiode,Endedatum",X, + 166,Positionsbezogener Abrechnungszeitraum Ende,SG26,DTM,2380,,,,"Datum oder Uhrzeit oderZeitspanne, Wert",X [UB3], + 167,Positionsbezogener Abrechnungszeitraum Ende,SG26,DTM,2379,,303,,CCYYMMDDHHMMZZZ,X, + 168,Ausführungsdatum,SG26,DTM,,,,,,,[10] Wenn SG26 DTM+155/156 nicht vorhanden + 169,Ausführungsdatum,SG26,DTM,2005,,203,,Ausführungsdatum/-zeit,, + 170,Ausführungsdatum,SG26,DTM,2380,,,,"Datum oder Uhrzeit oderZeitspanne, Wert",,[931] Format: ZZZ = +00 + 171,Ausführungsdatum,SG26,DTM,2379,,303,,CCYYMMDDHHMMZZZ,, + 172,Positionsnettobetrag,SG27,,,,,,,Muss, + 173,Positionsnettobetrag,SG27,MOA,,,,,,Muss, + 174,Positionsnettobetrag,SG27,MOA,5025,,203,,Positionsbetrag(ohne USt.),X, + 175,Positionsnettobetrag,SG27,MOA,5004,,,,Geldbetrag,X [930],[930] Format: max. 2 Nachkommastellen + 176,Gesamtzu- oder abschlagsbetrag,SG27,,,,,,,,"[26] Wenn SG39 ALC+A+:Z04 vorhanden + [27] Wenn SG39 ALC+C vorhanden" + 177,Gesamtzu- oder abschlagsbetrag,SG27,MOA,,,,,,, + 178,Gesamtzu- oder abschlagsbetrag,SG27,MOA,5025,,131,,Gesamtzu- oderabschlagsbetrag,, + 179,Gesamtzu- oder abschlagsbetrag,SG27,MOA,5004,,,,Geldbetrag,,[930] Format: max. 2 Nachkommastellen + 180,Preis,SG29,,,,,,,Muss, + 181,Preis,SG29,PRI,,,,,,Muss, + 182,Preis,SG29,PRI,5125,,CAL,,Berechnungspreis,X, + 183,Preis,SG29,PRI,5118,,,,"Preis, Betrag",X [912],"[912] Format: max. 6 Nachkommastellen + [946] Format: max. 11 Nachkommastellen" + 184,Preis,SG29,PRI,6411,,DAY,,Tag,, + 185,Preis,SG29,PRI,6411,,MON,,Monat,, + 186,Preis,SG29,PRI,6411,,ANN,,Jahr,,"[12] Wenn SG26 QTY+136 vorhanden + [51] Wenn SG26 DTM+156 (Positionsbezogener Abrechnungszeitraum Ende) ≤ 1.1.2023 0:00 gesetzlicher deutscher Zeit + [65] Wenn SG26 DTM+155 (Positionsbezogener Abrechnungszeitraum Beginn) ≥ 1.1.2024 0: 00 gesetzlicher deutscher Zeit + [77] Wenn SG26 DTM+156 (Positionsbezogener Abrechnungszeitraum Ende) ≤ 1.1.2024 0:00 gesetzlicher deutscher Zeit + [493] Wenn MP-ID in NAD+MR (Nachrichtenempfäng er) aus Sparte Gas" + 187,Umsatzsteuer der Position,SG34,,,,,,,Muss, + 188,Umsatzsteuer der Position,SG34,TAX,,,,,,Muss, + 189,Umsatzsteuer der Position,SG34,TAX,5283,,7,,Steuer,X, + 190,Umsatzsteuer der Position,SG34,TAX,5153,,VAT,,Umsatzsteuer,X, + 191,Umsatzsteuer der Position,SG34,TAX,5278,,,,Zoll-/Steuer-/Gebührenrate,X [902] ∧[930],"[902] Format: Möglicher Wert: ≥ 0 + [930] Format: max. 2 Nachkommastellen" + 192,Umsatzsteuer der Position,SG34,TAX,5305,,S,,Einheitssatz(Standard),X, + 193,Umsatzsteuer der Position,SG34,TAX,5305,,O,,nicht steuerbar,X, + 194,Abschlag,SG39,,,,,,,,[11] Wenn Abschlag anfällt + 195,Abschlag,SG39,ALC,,,,,,, + 196,Abschlag,SG39,ALC,5463,,A,,Abschlag,, + 197,Abschlag,SG39,ALC,5189,,Z01,,GemeinderabattnachKonzessionsabgabenverordnung,, + 198,Abschlag,SG39,ALC,5189,,Z04,,"Anpassung nach §19, Absatz 2Stromnetzentgeltverordnung",, + 199,Prozentangabe des Abschlags,SG41,PCD,,,,,,, + 200,Prozentangabe des Abschlags,SG41,PCD,5245,,3,,Zu- oder Abschlag,, + 201,Prozentangabe des Abschlags,SG41,PCD,5482,,,,Prozentsatz,,"[914] Format: Möglicher Wert: > 0 + [930] Format: max. 2 Nachkommastellen" + 202,Bemessungsgrundlage des Gemeinderabatts,SG42,,,,,,,,[32] Wenn SG39 ALC+A+:Z01 (Gemeinderabatt) vorhanden + 203,Bemessungsgrundlage des Gemeinderabatts,SG42,MOA,,,,,,, + 204,Bemessungsgrundlage des Gemeinderabatts,SG42,MOA,5025,,25,,Zu-/Abschlagsbasis,, + 205,Bemessungsgrundlage des Gemeinderabatts,SG42,MOA,5004,,,,Geldbetrag,,"[512] Hinweis: Hier ist entweder der Betrag aus MOA+203 oder der um den gültigen Steuerbetrag erhöhte Betrag aus MOA+203 anzugeben. + [930] Format: max. 2 Nachkommastellen" + 206,Gemeinderabatt der Position,SG42,,,,,,,,[32] Wenn SG39 ALC+A+:Z01 (Gemeinderabatt) vorhanden + 207,Gemeinderabatt der Position,SG42,MOA,,,,,,, + 208,Gemeinderabatt der Position,SG42,MOA,5025,,Z01,,Gemeinderabatt,, + 209,Gemeinderabatt der Position,SG42,MOA,5004,,,,Geldbetrag,,"[513] Hinweis: Hier ist das Ergebnis der Multiplikation von MOA+25 mit PCD+3 anzugeben. + [930] Format: max. 2 Nachkommastellen" + 210,Zuschlag,SG39,,,,,,,,[28] Wenn Zuschlag anfällt + 211,Zuschlag,SG39,ALC,,,,,,, + 212,Zuschlag,SG39,ALC,5463,,C,,Zuschlag,, + 213,Zuschlag,SG39,ALC,5189,,Z02,,Umspannungszuschlag,, + 214,Zuschlag,SG39,ALC,5189,,Z03,,"allein genutzteBetriebsmittel nach§ 19, Absatz 3Stromnetzentgeltverordnung",, + 215,Zuschlag,SG39,ALC,5189,,Z04,,"Anpassung nach §19, Absatz 2Stromnetzentgeltverordnung",, + 216,Zuschlag,SG39,ALC,5189,,Z05,,AnpassungPauschaleNetzentgeltreduzierung nach § 14aEnWG auf Höhe derNNE,,"[29] [Wenn DTM+155 (Abrechnungszeitraum Beginn) nicht größer 31.12.2015 + [525] Hinweis: Verwendung, sofern Netzentgelte geringer als die Pauschale Netzentgeltreduzierun g " + 217,Prozentangabe des Zuschlags,SG41,,,,,,,,[84] Wenn in dieser SG39 ALC+C+:Z02 / Z03 / Z04 vorhanden + 218,Prozentangabe des Zuschlags,SG41,PCD,,,,,,, + 219,Prozentangabe des Zuschlags,SG41,PCD,5245,,3,,Zu- oder Abschlag,, + 220,Prozentangabe des Zuschlags,SG41,PCD,5482,,,,Prozentsatz,,"[914] Format: Möglicher Wert: > 0 + [930] Format: max. 2 Nachkommastellen" + 221,Abschnitts- Kontrollsegment,,UNS,,,,,,Muss, + 222,Abschnitts- Kontrollsegment,,UNS,0081,,S,,Trennung vonPositions- undSummenteil,X, + 223,Rechnungsbetrag,SG50,,,,,,,Muss, + 224,Rechnungsbetrag,SG50,MOA,,,,,,Muss, + 225,Rechnungsbetrag,SG50,MOA,5025,,77,,Rechnungsbetrag,X, + 226,Rechnungsbetrag,SG50,MOA,5004,,,,Geldbetrag,X [930],[930] Format: max. 2 Nachkommastellen + 227,Vorausbezahlter Betrag,SG50,,,,,,,,"[13] Wenn vorausbezahlter Betrag vorliegt + [519] Hinweis: Stornierte Abschlagsrechnungen sind nicht aufzuführen" + 228,Vorausbezahlter Betrag,SG50,MOA,,,,,,, + 229,Vorausbezahlter Betrag,SG50,MOA,5025,,113,,VorausbezahlterBetrag (inkl. USt.),, + 230,Vorausbezahlter Betrag,SG50,MOA,5004,,,,Geldbetrag,,[930] Format: max. 2 Nachkommastellen + 231,Referenz auf Vorgängerrechnung,SG51,,,,,,,,"[22] Wenn vorhanden + [42] Wenn DTM+155 (Abrechnungszeitraum Beginn) ≥ 1.1.2023 0: 00 gesetzlicher deutscher Zeit + [54] Wenn IMD++ABR/JVR/ZVR vorhanden + [492] Wenn MP-ID in NAD+MR (Nachrichtenempfäng er) aus Sparte Strom" + 232,Referenz auf Vorgängerrechnung,SG51,RFF,,,,,,, + 233,Referenz auf Vorgängerrechnung,SG51,RFF,1153,,AFL,,ZugehörigeRechnungen,, + 234,Referenz auf Vorgängerrechnung,SG51,RFF,1154,,,,"Referenz, Identifikation",, + 235,Datum der Vorgängerrechnung,SG51,DTM,,,,,,, + 236,Datum der Vorgängerrechnung,SG51,DTM,2005,,3,,Rechnungsdatum/-zeit,, + 237,Datum der Vorgängerrechnung,SG51,DTM,2380,,,,"Datum oder Uhrzeit oderZeitspanne, Wert",, + 238,Datum der Vorgängerrechnung,SG51,DTM,2379,,303,,CCYYMMDDHHMMZZZ,, + 239,Gemeinderabatt,SG50,,,,,,,,[32] Wenn SG39 ALC+A+:Z01 (Gemeinderabatt) vorhanden + 240,Gemeinderabatt,SG50,MOA,,,,,,, + 241,Gemeinderabatt,SG50,MOA,5025,,Z01,,Gemeinderabatt,, + 242,Gemeinderabatt,SG50,MOA,5004,,,,Geldbetrag,,[930] Format: max. 2 Nachkommastellen + 243,Fälliger Betrag,SG50,,,,,,,Muss, + 244,Fälliger Betrag,SG50,MOA,,,,,,Muss, + 245,Fälliger Betrag,SG50,MOA,5025,,9,,Fälliger Betrag (inkl.USt.),X, + 246,Fälliger Betrag,SG50,MOA,5004,,,,Geldbetrag,X [930],[930] Format: max. 2 Nachkommastellen + 247,Umsatzsteuer der Rechnung,SG52,,,,,,,Muss, + 248,Umsatzsteuer der Rechnung,SG52,TAX,,,,,,Muss, + 249,Umsatzsteuer der Rechnung,SG52,TAX,5283,,7,,Steuer,X, + 250,Umsatzsteuer der Rechnung,SG52,TAX,5153,,VAT,,Umsatzsteuer,X, + 251,Umsatzsteuer der Rechnung,SG52,TAX,5278,,,,Zoll-/Steuer-/Gebührenrate,X [902] ∧[930],"[902] Format: Möglicher Wert: ≥ 0 + [930] Format: max. 2 Nachkommastellen" + 252,Umsatzsteuer der Rechnung,SG52,TAX,5305,,S,,Einheitssatz(Standard),X, + 253,Umsatzsteuer der Rechnung,SG52,TAX,5305,,O,,nicht steuerbar,X, + 254,Umsatzsteuer der Rechnung,SG52,TAX,5305,,AE,,Reverse Charge /Steuerschuldnerschaft desLeistungsempfängers,X, + 255,Vorausbezahlter Betrag (steuersatzbezogen),SG52,MOA,,,,,,,[13] Wenn vorausbezahlter Betrag vorliegt + 256,Vorausbezahlter Betrag (steuersatzbezogen),SG52,MOA,5025,,113,,VorausbezahlterBetrag (inkl. USt.),, + 257,Vorausbezahlter Betrag (steuersatzbezogen),SG52,MOA,5004,,,,Geldbetrag,,[930] Format: max. 2 Nachkommastellen + 258,Vorausbezahlte Steuern (steuersatzbezogen),SG52,MOA,,,,,,,[58] Wenn in dieser SG52 MOA+113 vorhanden + 259,Vorausbezahlte Steuern (steuersatzbezogen),SG52,MOA,5025,,115,,VorausbezahlteSteuern (USt.-Anteildes vorausbezahltenBetrages),, + 260,Vorausbezahlte Steuern (steuersatzbezogen),SG52,MOA,5004,,,,Geldbetrag,,[930] Format: max. 2 Nachkommastellen + 261,Besteuerungsgrundlage (steuersatzbezogen),SG52,MOA,,,,,,Muss, + 262,Besteuerungsgrundlage (steuersatzbezogen),SG52,MOA,5025,,125,,Besteuerungsgrundl,X, + 263,Besteuerungsgrundlage (steuersatzbezogen),SG52,MOA,5004,,,,Geldbetrag,X [930],[930] Format: max. 2 Nachkommastellen + 264,Steuerbetrag (steuersatzbezogen),SG52,MOA,,,,,,Muss, + 265,Steuerbetrag (steuersatzbezogen),SG52,MOA,5025,,161,,Steuer-/Gebühren-/Abgabebetrag,X, + 266,Steuerbetrag (steuersatzbezogen),SG52,MOA,5004,,,,Geldbetrag,X [930],[930] Format: max. 2 Nachkommastellen + 267,Nachrichtenende,,UNT,,,,,,Muss, + 268,Nachrichtenende,,UNT,0074,,,,Anzahl der Segmente ineiner Nachricht,X, + 269,Nachrichtenende,,UNT,0062,,,,Nachrichten-Referenznummer,X, + + ''' +# --- +# name: TestCli.test_kohlrahbi_cli_with_valid_arguments[31003] + ''' + ,Segmentname,Segmentgruppe,Segment,Datenelement,Segment ID,Code,Qualifier,Beschreibung,Bedingungsausdruck,Bedingung + 0,Nachrichtenanfang,,UNH,,,,,,Muss, + 1,Nachrichtenanfang,,UNH,0062,,,,Nachrichten-Referenznummer,X, + 2,Nachrichtenanfang,,UNH,0065,,INVOIC,,Rechnung,X, + 3,Nachrichtenanfang,,UNH,0052,,D,,Entwurfs-Version,X, + 4,Nachrichtenanfang,,UNH,0054,,06A,,Ausgabe 2006 - A,X, + 5,Nachrichtenanfang,,UNH,0051,,UN,,UN/CEFACT,X, + 6,Nachrichtenanfang,,UNH,0057,,2.8c,,VersionsnummerderzugrundeliegendenBDEW-Nachrichtenbeschreibung,X, + 7,Rechnungsnummer,,BGM,,,,,,Muss, + 8,Rechnungsnummer,,BGM,1001,,380,,Handelsrechnung,X, + 9,Rechnungsnummer,,BGM,1004,,,,Dokumentennummer,X, + 10,Rechnungsnummer,,BGM,1225,,7,,Duplikat,X, + 11,Rechnungsnummer,,BGM,1225,,9,,Original,X, + 12,Nachrichtendatum,,DTM,,,,,,Muss, + 13,Nachrichtendatum,,DTM,2005,,137,,Dokumenten-/Nachrichtendatum/-zeit,X, + 14,Nachrichtendatum,,DTM,2380,,,,"Datum oder Uhrzeit oderZeitspanne, Wert",X [931],[931] Format: ZZZ = +00 + 15,Nachrichtendatum,,DTM,2379,,303,,CCYYMMDDHHMMZZZ,X, + 16,Bearbeitungs-/ Verarbeitungsdatum,,DTM,,,,,,Muss, + 17,Bearbeitungs-/ Verarbeitungsdatum,,DTM,2005,,9,,Bearbeitungs-/Verarbeitungsdatum/-zeit,X, + 18,Bearbeitungs-/ Verarbeitungsdatum,,DTM,2380,,,,"Datum oder Uhrzeit oderZeitspanne, Wert",X [931],[931] Format: ZZZ = +00 + 19,Bearbeitungs-/ Verarbeitungsdatum,,DTM,2379,,303,,CCYYMMDDHHMMZZZ,X, + 20,Abrechnungszeitraum Beginn,,DTM,,,,,,Soll [2],[2] Wenn es sich um eine Nutzungsüberlassung (Pacht) eines Gerätes handelt + 21,Abrechnungszeitraum Beginn,,DTM,2005,,155,,"Rechnungsperiode,Beginndatum",X, + 22,Abrechnungszeitraum Beginn,,DTM,2380,,,,"Datum oder Uhrzeit oderZeitspanne, Wert",X [UB3], + 23,Abrechnungszeitraum Beginn,,DTM,2379,,303,,CCYYMMDDHHMMZZZ,X, + 24,Abrechnungszeitraum Ende,,DTM,,,,,,Soll [2],[2] Wenn es sich um eine Nutzungsüberlassung (Pacht) eines Gerätes handelt + 25,Abrechnungszeitraum Ende,,DTM,2005,,156,,"Rechnungsperiode,Endedatum",X, + 26,Abrechnungszeitraum Ende,,DTM,2380,,,,"Datum oder Uhrzeit oderZeitspanne, Wert",X [UB3], + 27,Abrechnungszeitraum Ende,,DTM,2379,,303,,CCYYMMDDHHMMZZZ,X, + 28,vorläufiger Abrechnungszeitraum Beginn,,DTM,,,,,,, + 29,vorläufiger Abrechnungszeitraum Beginn,,DTM,2005,,Z42,,vorläufigerAbrechnungszeitraum Beginn,, + 30,vorläufiger Abrechnungszeitraum Beginn,,DTM,2380,,,,"Datum oder Uhrzeit oderZeitspanne, Wert",, + 31,vorläufiger Abrechnungszeitraum Beginn,,DTM,2379,,303,,CCYYMMDDHHMMZZZ,, + 32,vorläufiger Abrechnungszeitraum Ende,,DTM,,,,,,, + 33,vorläufiger Abrechnungszeitraum Ende,,DTM,2005,,Z43,,vorläufigerAbrechnungszeitraum Ende,, + 34,vorläufiger Abrechnungszeitraum Ende,,DTM,2380,,,,"Datum oder Uhrzeit oderZeitspanne, Wert",, + 35,vorläufiger Abrechnungszeitraum Ende,,DTM,2379,,303,,CCYYMMDDHHMMZZZ,, + 36,Ausführungsdatum,,DTM,,,,,,Soll [3],[3] Wenn es sich um einen Kauf eines Gerätes handelt + 37,Ausführungsdatum,,DTM,2005,,203,,Ausführungsdatum/-zeit,X, + 38,Ausführungsdatum,,DTM,2380,,,,"Datum oder Uhrzeit oderZeitspanne, Wert",X [931],[931] Format: ZZZ = +00 + 39,Ausführungsdatum,,DTM,2379,,303,,CCYYMMDDHHMMZZZ,X, + 40,Rechnungstyp,,IMD,,,,,,Muss, + 41,Rechnungstyp,,IMD,7081,,ABR,,Abschlussrechnung,, + 42,Rechnungstyp,,IMD,7081,,ABS,,Abschlagsrechnung,,[56] Wenn DTM+137 (Nachrichtendatum ≥ + 43,Meldeinformationen,,FTX,,,,,,Soll [4],[4] Wenn Steuerschuldnerschaft des Leistungsempfängers vorliegt + 44,Meldeinformationen,,FTX,4451,,REG,,Meldeinformationen,X, + 45,Meldeinformationen,,FTX,4441,,RCH,,Reverse Chargegemäß §13b UStG /Steuerschuldnerschaft desLeistungsempfängers,X, + 46,Spezifikation der Sonderrechnung,,GEI,,,,,,,[41] Wenn IMD++SOR vorhanden + 47,Spezifikation der Sonderrechnung,,GEI,9649,,Z01,,Art derSonderrechnung,, + 48,Spezifikation der Sonderrechnung,,GEI,7365,,Z01,,Konzessionsabgabe(Testat),, + 49,Spezifikation der Sonderrechnung,,GEI,7365,,Z02,,IndividuelleVereinbarung füratypische undenergieintensiveNetznutzung,, + 50,Spezifikation der Sonderrechnung,,GEI,7365,,Z03,,IndividuelleVereinbarung fürsinguläreNetznutzung,,"[78] Wenn GEI+Z08 nicht vorhanden + [79] Wenn GEI+Z09 nicht vorhanden + [80] Wenn GEI+Z01 nicht vorhanden + [81] Wenn GEI+Z04 nicht vorhanden + [82] Wenn GEI+Z05 nicht vorhanden" + 51,Prüfidentifikator,SG1,,,,,,,Muss, + 52,Prüfidentifikator,SG1,RFF,,,,,,Muss, + 53,Prüfidentifikator,SG1,RFF,1153,,Z13,,Prüfidentifikator,X, + 54,Prüfidentifikator,SG1,RFF,1154,,31001,,Abschlagsrechnung,, + 55,Prüfidentifikator,SG1,RFF,1154,,31002,,NN-Rechnung,, + 56,Prüfidentifikator,SG1,RFF,1154,,31003,,WiM-Rechnung,X, + 57,Prüfidentifikator,SG1,RFF,1154,,31009,,MSB-Rechnung,, + 58,Referenz auf Ursprungsrechnungsnum mer,SG1,,,,,,,,[41] Wenn IMD++SOR vorhanden + 59,Referenz auf Ursprungsrechnungsnum mer,SG1,RFF,,,,,,, + 60,Referenz auf Ursprungsrechnungsnum mer,SG1,RFF,1153,,OI,,Ursprungsrechnungsnummer,, + 61,Referenz auf Ursprungsrechnungsnum mer,SG1,RFF,1154,,,,"Referenz, Identifikation",, + 62,Referenzdatum,SG1,DTM,,,,,,, + 63,Referenzdatum,SG1,DTM,2005,,171,,Referenzdatum/-zeit,, + 64,Referenzdatum,SG1,DTM,2380,,,,"Datum oder Uhrzeit oderZeitspanne, Wert",, + 65,Referenzdatum,SG1,DTM,2379,,303,,CCYYMMDDHHMMZZZ,, + 66,Referenz auf Nummer des zugehörigen Dokuments,SG1,,,,,,,Muss,"[36] Wenn DTM+156 (Abrechnungszeitraum Ende) ≥ 01.12.2019 + [37] Wenn Lieferschein zuvor ausgetauscht wurde + [50] Wenn IMD++SOR nicht vorhanden + [66] Wenn IMD++KON vorhanden + [72] Wenn MP-ID in NAD+MR in der Rolle LF + [73] Wenn IMD++MSB" + 67,Referenz auf Nummer des zugehörigen Dokuments,SG1,RFF,,,,,,Muss, + 68,Referenz auf Nummer des zugehörigen Dokuments,SG1,RFF,1153,,ACE,,Nummer deszugehörigenDokuments,X, + 69,Referenz auf Nummer des zugehörigen Dokuments,SG1,RFF,1154,,,,"Referenz, Identifikation",X [501],"[66] Wenn IMD++KON vorhanden + [73] Wenn IMD++MSB vorhanden + [501] Hinweis: Dokumentennummer der ORDERS + [508] Hinweis: Dokumentennummer der QUOTES + [514] Hinweis: Dokumentennummer der Lieferschein- MSCONS" + 70,Name und Anschrift des Nachrichtensenders,SG2,,,,,,,Muss, + 71,Name und Anschrift des Nachrichtensenders,SG2,NAD,,,,,,Muss, + 72,Name und Anschrift des Nachrichtensenders,SG2,NAD,3035,,MS,,Dokumenten-/Nachrichtenaussteller bzw. -absender,X, + 73,Name und Anschrift des Nachrichtensenders,SG2,NAD,3039,,,,MP-ID,X,[45] Nur MP-ID aus Sparte Strom + 74,Name und Anschrift des Nachrichtensenders,SG2,NAD,3055,,9,,GS1,X, + 75,Name und Anschrift des Nachrichtensenders,SG2,NAD,3055,,293,,"DE, BDEW(Bundesverband derEnergie- undWasserwirtschafte.V.)",X, + 76,Name und Anschrift des Nachrichtensenders,SG2,NAD,3055,,332,,"DE, DVGW Service &Consult GmbH",X, + 77,Name und Anschrift des Nachrichtensenders,SG2,NAD,3036,,,,Beteiligter,X, + 78,Name und Anschrift des Nachrichtensenders,SG2,NAD,3045,,Z01,,Struktur vonPersonennamen,X, + 79,Name und Anschrift des Nachrichtensenders,SG2,NAD,3045,,Z02,,Struktur derFirmenbezeichnung,X, + 80,Name und Anschrift des Nachrichtensenders,SG2,NAD,3042,,,,Straße und Hausnummeroder Postfach,S [7],[7] Sofern keine Großkundenpostleitza hl verwendet wird + 81,Name und Anschrift des Nachrichtensenders,SG2,NAD,3164,,,,Ort,M, + 82,Name und Anschrift des Nachrichtensenders,SG2,NAD,3251,,,,"Postleitzahl, Code",X, + 83,Name und Anschrift des Nachrichtensenders,SG2,NAD,3207,,,,"Ländername, Code",X, + 84,"Steuernummer, Umsatzsteuernummer",SG3,,,,,,,Muss, + 85,"Steuernummer, Umsatzsteuernummer",SG3,RFF,,,,,,Muss, + 86,"Steuernummer, Umsatzsteuernummer",SG3,RFF,1153,,VA,,Umsatzsteuernummer,X, + 87,"Steuernummer, Umsatzsteuernummer",SG3,RFF,1153,,FC,,Steuernummer,X [6],[6] Wenn NAD+MR DE3207 = „DE“ + 88,"Steuernummer, Umsatzsteuernummer",SG3,RFF,1154,,,,"Referenz, Identifikation",X, + 89,Ansprechpartner,SG5,,,,,,,Kann, + 90,Ansprechpartner,SG5,CTA,,,,,,Muss, + 91,Ansprechpartner,SG5,CTA,3139,,IC,,Informationskontakt,X, + 92,Ansprechpartner,SG5,CTA,3412,,,,Kontakt,X, + 93,Kommunikationsverbindu ng,SG5,COM,,,,,,Muss, + 94,Kommunikationsverbindu ng,SG5,COM,3148,,,,"Kommunikationsadresse,Identifikation",X (([939][74]) ∨([940][75]))∧ [524],"[74] wenn im DE3155 in demselben COM der Code EM vorhanden ist + [75] wenn im DE3155 in demselben COM der Code TE / FX / AJ / AL vorhanden ist + [524] Hinweis: Es darf nur eine Information im DE3148 übermittelt werden + [939] Format: Die Zeichenkette muss die Zeichen @ und . enthalten + [940] Format: Die Zeichenkette muss mit dem Zeichen + beginnen und danach dürfen nur noch Ziffern folgen" + 95,Kommunikationsverbindu ng,SG5,COM,3155,,EM,,Elektronische Post,X [1P0..1], + 96,Kommunikationsverbindu ng,SG5,COM,3155,,FX,,Telefax,X [1P0..1], + 97,Kommunikationsverbindu ng,SG5,COM,3155,,TE,,Telefon,X [1P0..1], + 98,Name und Anschrift des Nachrichtenempfängers,SG2,,,,,,,Muss, + 99,Name und Anschrift des Nachrichtenempfängers,SG2,NAD,,,,,,Muss, + 100,Name und Anschrift des Nachrichtenempfängers,SG2,NAD,3035,,MR,,Nachrichtenempfänger,X, + 101,Name und Anschrift des Nachrichtenempfängers,SG2,NAD,3039,,,,MP-ID,X,[45] Nur MP-ID aus Sparte Strom + 102,Name und Anschrift des Nachrichtenempfängers,SG2,NAD,3055,,9,,GS1,X, + 103,Name und Anschrift des Nachrichtenempfängers,SG2,NAD,3055,,293,,"DE, BDEW(Bundesverband derEnergie- undWasserwirtschafte.V.)",X, + 104,Name und Anschrift des Nachrichtenempfängers,SG2,NAD,3055,,332,,"DE, DVGW Service &Consult GmbH",X, + 105,Name und Anschrift des Nachrichtenempfängers,SG2,NAD,3036,,,,Beteiligter,X, + 106,Name und Anschrift des Nachrichtenempfängers,SG2,NAD,3045,,Z01,,Struktur vonPersonennamen,X, + 107,Name und Anschrift des Nachrichtenempfängers,SG2,NAD,3045,,Z02,,Struktur derFirmenbezeichnung,X, + 108,Name und Anschrift des Nachrichtenempfängers,SG2,NAD,3042,,,,Straße und Hausnummeroder Postfach,S [7],[7] Sofern keine Großkundenpostleitza hl verwendet wird + 109,Name und Anschrift des Nachrichtenempfängers,SG2,NAD,3164,,,,Ort,M, + 110,Name und Anschrift des Nachrichtenempfängers,SG2,NAD,3251,,,,"Postleitzahl, Code",X, + 111,Name und Anschrift des Nachrichtenempfängers,SG2,NAD,3207,,,,"Ländername, Code",X, + 112,"Steuernummer, Umsatzsteuernummer",SG3,,,,,,,Muss [5]Soll [4],"[4] Wenn Steuerschuldnerschaft des Leistungsempfängers vorliegt + [5] Wenn NAD+MR DE3207 <> „DE“" + 113,"Steuernummer, Umsatzsteuernummer",SG3,RFF,,,,,,Muss, + 114,"Steuernummer, Umsatzsteuernummer",SG3,RFF,1153,,VA,,Umsatzsteuernummer,X, + 115,"Steuernummer, Umsatzsteuernummer",SG3,RFF,1153,,FC,,Steuernummer,X [6],[6] Wenn NAD+MR DE3207 = „DE“ + 116,"Steuernummer, Umsatzsteuernummer",SG3,RFF,1154,,,,"Referenz, Identifikation",X, + 117,Adresse der Leistungserbringung,SG2,,,,,,,Muss, + 118,Adresse der Leistungserbringung,SG2,NAD,,,,,,Muss, + 119,Adresse der Leistungserbringung,SG2,NAD,3035,,DP,,Lieferanschrift,X, + 120,Adresse der Leistungserbringung,SG2,NAD,3124,,,,Zusatzinformation zurIdentifizierung,K, + 121,Adresse der Leistungserbringung,SG2,NAD,3042,,,,Straße und Hausnummeroder Postfach,S [22]M [23],"[22] Wenn vorhanden + [23] Wenn im selben" + 122,Adresse der Leistungserbringung,SG2,NAD,3164,,,,Ort,M, + 123,Adresse der Leistungserbringung,SG2,NAD,3251,,,,"Postleitzahl, Code",X, + 124,Adresse der Leistungserbringung,SG2,NAD,3207,,,,"Ländername, Code",X, + 125,Meldepunkt,SG2,LOC,,,,,,Muss, + 126,Meldepunkt,SG2,LOC,3227,,172,,Meldepunkt,X, + 127,Meldepunkt,SG2,LOC,3225,,,,"Ortsangabe, Nummer",X [951][510],"[509] Hinweis: Verwendung der ID der Marktlokation + [510] Hinweis: Verwendung der ID der Messlokation + [522] Hinweis: Verwendung der ID der Netzlokation + [523] Hinweis: Verwendung der ID der Steuerbaren Ressource + [950] Format: Marktlokations-ID + [951] Format: Zählpunktbezeichnung + [960] Format: Netzlokations-ID + [961] Format: SR-ID" + 128,Währungsangaben,SG7,,,,,,,Muss, + 129,Währungsangaben,SG7,CUX,,,,,,Muss, + 130,Währungsangaben,SG7,CUX,6347,,2,,Referenzwährung,X, + 131,Währungsangaben,SG7,CUX,6345,,EUR,,Euro,X, + 132,Währungsangaben,SG7,CUX,6343,,4,,Währung derRechnung,X, + 133,Zahlungsbedingungen,SG8,,,,,,,Muss, + 134,Zahlungsbedingungen,SG8,PYT,,,,,,Muss, + 135,Zahlungsbedingungen,SG8,PYT,4279,,3,,Fixdatum,X, + 136,Fälligkeitsdatum,SG8,DTM,,,,,,Muss, + 137,Fälligkeitsdatum,SG8,DTM,2005,,265,,Fälligkeitsdatum,X, + 138,Fälligkeitsdatum,SG8,DTM,2380,,,,"Datum oder Uhrzeit oderZeitspanne, Wert",X [UB1] ∧(([493] ∧[20] ∧ [24])⊻ ([493] ∧[21] ∧ [25])⊻ [492]),"[20] Wenn fälliger Betrag (SG50 MOA+9) ≥ 0 + [21] Wenn fälliger Betrag (SG50 MOA+9) < 0 + [24] Wert muss" + 139,Fälligkeitsdatum,SG8,DTM,2379,,303,,CCYYMMDDHHMMZZZ,X, + 140,Positionsdaten,SG26,,,,,,,Muss, + 141,Positionsdaten,SG26,LIN,,,,,,Muss, + 142,Positionsdaten,SG26,LIN,1082,,,,Positionsnummer,X [911],"[911] Format: Mögliche Werte: 1 bis n, je Nachricht oder Segmentgruppe bei 1 beginnend und fortlaufend aufsteigend" + 143,Positionsdaten,SG26,LIN,7140,,,,Produkt-/Leistungsnummer,X [40],"[40] Es sind nur die Artikelnummern erlaubt, die in der Codeliste der Artikelnummern und Artikel-ID mit dem entsprechenden Prüfidentifikator versehen sind oder Artikel-ID aus der Codeliste der Artikelnummern und Artikel-ID. + [41] Wenn IMD++SOR vorhanden + [50] Wenn IMD++SOR nicht vorhanden + [67] Es sind nur die Artikelnummern erlaubt, die im Kapitel 2 „Codeliste der Artikelnummer“ in der Codeliste der Artikelnummern und Artikel-ID ein „X“ für den entsprechenden Prüfidentifikator" + 144,Positionsdaten,SG26,LIN,7143,,Z01,,Artikelnummer,X, + 145,Positionsdaten,SG26,LIN,7143,,Z09,,Artikel-ID,,"[51] Wenn SG26 DTM+156 (Positionsbezogener Abrechnungszeitraum Ende) ≤ 1.1.2023 0:00 gesetzlicher deutscher Zeit + [59] Wenn SG26 DTM+155 (Positionsbezogener Abrechnungszeitraum Beginn) ≥ 1.1.2023 0: 00 gesetzlicher deutscher Zeit + [65] Wenn SG26 DTM+155 (Positionsbezogener Abrechnungszeitraum Beginn) ≥ 1.1.2024 0: 00 gesetzlicher deutscher Zeit + [66] Wenn IMD++KON vorhanden + [77] Wenn SG26 DTM+156 (Positionsbezogener Abrechnungszeitraum Ende) ≤ 1.1.2024 0:00 gesetzlicher deutscher Zeit + [492] Wenn MP-ID in NAD+MR (Nachrichtenempfäng" + 146,energetische Mengenangaben,SG26,QTY,,,,,,Muss, + 147,energetische Mengenangaben,SG26,QTY,6063,,47,,Berechnete(fakturierte) Menge,X, + 148,energetische Mengenangaben,SG26,QTY,6060,,,,Menge,X [902] ∧[906],"[902] Format: Möglicher Wert: ≥ 0 + [906] Format: max. 3 Nachkommastellen + [910] Format: Möglicher Wert: < 0 oder ≥ 0 " + 149,energetische Mengenangaben,SG26,QTY,6411,,KWH,,Kilowattstunde,, + 150,energetische Mengenangaben,SG26,QTY,6411,,KWT,,Kilowatt,, + 151,energetische Mengenangaben,SG26,QTY,6411,,KVR,,kilovar,, + 152,energetische Mengenangaben,SG26,QTY,6411,,K3,,kilovolt ampere,, + 153,energetische Mengenangaben,SG26,QTY,6411,,H87,,Stück,X,"[51] Wenn SG26 DTM+156 (Positionsbezogener Abrechnungszeitraum Ende) ≤ 1.1.2023 0:00 gesetzlicher deutscher Zeit + [492] Wenn MP-ID in NAD+MR (Nachrichtenempfäng er) aus Sparte Strom" + 154,zeitliche Mengenangaben,SG26,QTY,,,,,,Soll [8],[8] Bei zeitabhängigen Preisen + 155,zeitliche Mengenangaben,SG26,QTY,6063,,136,,Erreichte Menge indem Zeitintervall,X, + 156,zeitliche Mengenangaben,SG26,QTY,6060,,,,Menge,X [908],[908] Format: Mögliche Werte: 1 bis n + 157,zeitliche Mengenangaben,SG26,QTY,6411,,DAY,,Tag,X, + 158,zeitliche Mengenangaben,SG26,QTY,6411,,MON,,Monat,X, + 159,zeitliche Mengenangaben,SG26,QTY,6411,,ANN,,Jahr,X,"[51] Wenn SG26 DTM+156 (Positionsbezogener Abrechnungszeitraum Ende) ≤ 1.1.2023 0:00 gesetzlicher deutscher Zeit + [64] Wenn DTM+156 (Abrechnungszeitraum Ende) ≤ 1.1.2024 0:00 gesetzlicher deutscher Zeit + [493] Wenn MP-ID in NAD+MR (Nachrichtenempfäng er) aus Sparte Gas" + 160,Positionsbezogener Abrechnungszeitraum Beginn,SG26,DTM,,,,,,Muss [9],[9] Wenn SG26 DTM+203 nicht vorhanden + 161,Positionsbezogener Abrechnungszeitraum Beginn,SG26,DTM,2005,,155,,"Rechnungsperiode,Beginndatum",X, + 162,Positionsbezogener Abrechnungszeitraum Beginn,SG26,DTM,2380,,,,"Datum oder Uhrzeit oderZeitspanne, Wert",X [UB3], + 163,Positionsbezogener Abrechnungszeitraum Beginn,SG26,DTM,2379,,303,,CCYYMMDDHHMMZZZ,X, + 164,Positionsbezogener Abrechnungszeitraum Ende,SG26,DTM,,,,,,Muss [9],[9] Wenn SG26 DTM+203 nicht vorhanden + 165,Positionsbezogener Abrechnungszeitraum Ende,SG26,DTM,2005,,156,,"Rechnungsperiode,Endedatum",X, + 166,Positionsbezogener Abrechnungszeitraum Ende,SG26,DTM,2380,,,,"Datum oder Uhrzeit oderZeitspanne, Wert",X [UB3], + 167,Positionsbezogener Abrechnungszeitraum Ende,SG26,DTM,2379,,303,,CCYYMMDDHHMMZZZ,X, + 168,Ausführungsdatum,SG26,DTM,,,,,,Muss [10],[10] Wenn SG26 DTM+155/156 nicht vorhanden + 169,Ausführungsdatum,SG26,DTM,2005,,203,,Ausführungsdatum/-zeit,X, + 170,Ausführungsdatum,SG26,DTM,2380,,,,"Datum oder Uhrzeit oderZeitspanne, Wert",X [931],[931] Format: ZZZ = +00 + 171,Ausführungsdatum,SG26,DTM,2379,,303,,CCYYMMDDHHMMZZZ,X, + 172,Positionsnettobetrag,SG27,,,,,,,Muss, + 173,Positionsnettobetrag,SG27,MOA,,,,,,Muss, + 174,Positionsnettobetrag,SG27,MOA,5025,,203,,Positionsbetrag(ohne USt.),X, + 175,Positionsnettobetrag,SG27,MOA,5004,,,,Geldbetrag,X [930],[930] Format: max. 2 Nachkommastellen + 176,Gesamtzu- oder abschlagsbetrag,SG27,,,,,,,,"[26] Wenn SG39 ALC+A+:Z04 vorhanden + [27] Wenn SG39 ALC+C vorhanden" + 177,Gesamtzu- oder abschlagsbetrag,SG27,MOA,,,,,,, + 178,Gesamtzu- oder abschlagsbetrag,SG27,MOA,5025,,131,,Gesamtzu- oderabschlagsbetrag,, + 179,Gesamtzu- oder abschlagsbetrag,SG27,MOA,5004,,,,Geldbetrag,,[930] Format: max. 2 Nachkommastellen + 180,Preis,SG29,,,,,,,Muss, + 181,Preis,SG29,PRI,,,,,,Muss, + 182,Preis,SG29,PRI,5125,,CAL,,Berechnungspreis,X, + 183,Preis,SG29,PRI,5118,,,,"Preis, Betrag",X [912],"[912] Format: max. 6 Nachkommastellen + [946] Format: max. 11 Nachkommastellen" + 184,Preis,SG29,PRI,6411,,DAY,,Tag,X [12], + 185,Preis,SG29,PRI,6411,,MON,,Monat,X [12], + 186,Preis,SG29,PRI,6411,,ANN,,Jahr,X [12],"[12] Wenn SG26 QTY+136 vorhanden + [51] Wenn SG26 DTM+156 (Positionsbezogener Abrechnungszeitraum Ende) ≤ 1.1.2023 0:00 gesetzlicher deutscher Zeit + [65] Wenn SG26 DTM+155 (Positionsbezogener Abrechnungszeitraum Beginn) ≥ 1.1.2024 0: 00 gesetzlicher deutscher Zeit + [77] Wenn SG26 DTM+156 (Positionsbezogener Abrechnungszeitraum Ende) ≤ 1.1.2024 0:00 gesetzlicher deutscher Zeit + [493] Wenn MP-ID in NAD+MR (Nachrichtenempfäng er) aus Sparte Gas" + 187,Umsatzsteuer der Position,SG34,,,,,,,Muss, + 188,Umsatzsteuer der Position,SG34,TAX,,,,,,Muss, + 189,Umsatzsteuer der Position,SG34,TAX,5283,,7,,Steuer,X, + 190,Umsatzsteuer der Position,SG34,TAX,5153,,VAT,,Umsatzsteuer,X, + 191,Umsatzsteuer der Position,SG34,TAX,5278,,,,Zoll-/Steuer-/Gebührenrate,X [902] ∧[930],"[902] Format: Möglicher Wert: ≥ 0 + [930] Format: max. 2 Nachkommastellen" + 192,Umsatzsteuer der Position,SG34,TAX,5305,,S,,Einheitssatz(Standard),X, + 193,Umsatzsteuer der Position,SG34,TAX,5305,,O,,nicht steuerbar,X, + 194,Abschlag,SG39,,,,,,,,[11] Wenn Abschlag anfällt + 195,Abschlag,SG39,ALC,,,,,,, + 196,Abschlag,SG39,ALC,5463,,A,,Abschlag,, + 197,Abschlag,SG39,ALC,5189,,Z01,,GemeinderabattnachKonzessionsabgabenverordnung,, + 198,Abschlag,SG39,ALC,5189,,Z04,,"Anpassung nach §19, Absatz 2Stromnetzentgeltverordnung",, + 199,Prozentangabe des Abschlags,SG41,PCD,,,,,,, + 200,Prozentangabe des Abschlags,SG41,PCD,5245,,3,,Zu- oder Abschlag,, + 201,Prozentangabe des Abschlags,SG41,PCD,5482,,,,Prozentsatz,,"[914] Format: Möglicher Wert: > 0 + [930] Format: max. 2 Nachkommastellen" + 202,Bemessungsgrundlage des Gemeinderabatts,SG42,,,,,,,,[32] Wenn SG39 ALC+A+:Z01 (Gemeinderabatt) vorhanden + 203,Bemessungsgrundlage des Gemeinderabatts,SG42,MOA,,,,,,, + 204,Bemessungsgrundlage des Gemeinderabatts,SG42,MOA,5025,,25,,Zu-/Abschlagsbasis,, + 205,Bemessungsgrundlage des Gemeinderabatts,SG42,MOA,5004,,,,Geldbetrag,,"[512] Hinweis: Hier ist entweder der Betrag aus MOA+203 oder der um den gültigen Steuerbetrag erhöhte Betrag aus MOA+203 anzugeben. + [930] Format: max. 2 Nachkommastellen" + 206,Gemeinderabatt der Position,SG42,,,,,,,,[32] Wenn SG39 ALC+A+:Z01 (Gemeinderabatt) vorhanden + 207,Gemeinderabatt der Position,SG42,MOA,,,,,,, + 208,Gemeinderabatt der Position,SG42,MOA,5025,,Z01,,Gemeinderabatt,, + 209,Gemeinderabatt der Position,SG42,MOA,5004,,,,Geldbetrag,,"[513] Hinweis: Hier ist das Ergebnis der Multiplikation von MOA+25 mit PCD+3 anzugeben. + [930] Format: max. 2 Nachkommastellen" + 210,Zuschlag,SG39,,,,,,,,[28] Wenn Zuschlag anfällt + 211,Zuschlag,SG39,ALC,,,,,,, + 212,Zuschlag,SG39,ALC,5463,,C,,Zuschlag,, + 213,Zuschlag,SG39,ALC,5189,,Z02,,Umspannungszuschlag,, + 214,Zuschlag,SG39,ALC,5189,,Z03,,"allein genutzteBetriebsmittel nach§ 19, Absatz 3Stromnetzentgeltverordnung",, + 215,Zuschlag,SG39,ALC,5189,,Z04,,"Anpassung nach §19, Absatz 2Stromnetzentgeltverordnung",, + 216,Zuschlag,SG39,ALC,5189,,Z05,,AnpassungPauschaleNetzentgeltreduzierung nach § 14aEnWG auf Höhe derNNE,,"[29] [Wenn DTM+155 (Abrechnungszeitraum Beginn) nicht größer 31.12.2015 + [525] Hinweis: Verwendung, sofern Netzentgelte geringer als die Pauschale Netzentgeltreduzierun g " + 217,Prozentangabe des Zuschlags,SG41,,,,,,,,[84] Wenn in dieser SG39 ALC+C+:Z02 / Z03 / Z04 vorhanden + 218,Prozentangabe des Zuschlags,SG41,PCD,,,,,,, + 219,Prozentangabe des Zuschlags,SG41,PCD,5245,,3,,Zu- oder Abschlag,, + 220,Prozentangabe des Zuschlags,SG41,PCD,5482,,,,Prozentsatz,,"[914] Format: Möglicher Wert: > 0 + [930] Format: max. 2 Nachkommastellen" + 221,Abschnitts- Kontrollsegment,,UNS,,,,,,Muss, + 222,Abschnitts- Kontrollsegment,,UNS,0081,,S,,Trennung vonPositions- undSummenteil,X, + 223,Rechnungsbetrag,SG50,,,,,,,Muss, + 224,Rechnungsbetrag,SG50,MOA,,,,,,Muss, + 225,Rechnungsbetrag,SG50,MOA,5025,,77,,Rechnungsbetrag,X, + 226,Rechnungsbetrag,SG50,MOA,5004,,,,Geldbetrag,X [930],[930] Format: max. 2 Nachkommastellen + 227,Vorausbezahlter Betrag,SG50,,,,,,,,"[13] Wenn vorausbezahlter Betrag vorliegt + [519] Hinweis: Stornierte Abschlagsrechnungen sind nicht aufzuführen" + 228,Vorausbezahlter Betrag,SG50,MOA,,,,,,, + 229,Vorausbezahlter Betrag,SG50,MOA,5025,,113,,VorausbezahlterBetrag (inkl. USt.),, + 230,Vorausbezahlter Betrag,SG50,MOA,5004,,,,Geldbetrag,,[930] Format: max. 2 Nachkommastellen + 231,Referenz auf Vorgängerrechnung,SG51,,,,,,,,"[22] Wenn vorhanden + [42] Wenn DTM+155 (Abrechnungszeitraum Beginn) ≥ 1.1.2023 0: 00 gesetzlicher deutscher Zeit + [54] Wenn IMD++ABR/JVR/ZVR vorhanden + [492] Wenn MP-ID in NAD+MR (Nachrichtenempfäng er) aus Sparte Strom" + 232,Referenz auf Vorgängerrechnung,SG51,RFF,,,,,,, + 233,Referenz auf Vorgängerrechnung,SG51,RFF,1153,,AFL,,ZugehörigeRechnungen,, + 234,Referenz auf Vorgängerrechnung,SG51,RFF,1154,,,,"Referenz, Identifikation",, + 235,Datum der Vorgängerrechnung,SG51,DTM,,,,,,, + 236,Datum der Vorgängerrechnung,SG51,DTM,2005,,3,,Rechnungsdatum/-zeit,, + 237,Datum der Vorgängerrechnung,SG51,DTM,2380,,,,"Datum oder Uhrzeit oderZeitspanne, Wert",, + 238,Datum der Vorgängerrechnung,SG51,DTM,2379,,303,,CCYYMMDDHHMMZZZ,, + 239,Gemeinderabatt,SG50,,,,,,,,[32] Wenn SG39 ALC+A+:Z01 (Gemeinderabatt) vorhanden + 240,Gemeinderabatt,SG50,MOA,,,,,,, + 241,Gemeinderabatt,SG50,MOA,5025,,Z01,,Gemeinderabatt,, + 242,Gemeinderabatt,SG50,MOA,5004,,,,Geldbetrag,,[930] Format: max. 2 Nachkommastellen + 243,Fälliger Betrag,SG50,,,,,,,Muss, + 244,Fälliger Betrag,SG50,MOA,,,,,,Muss, + 245,Fälliger Betrag,SG50,MOA,5025,,9,,Fälliger Betrag (inkl.USt.),X, + 246,Fälliger Betrag,SG50,MOA,5004,,,,Geldbetrag,X [930],[930] Format: max. 2 Nachkommastellen + 247,Umsatzsteuer der Rechnung,SG52,,,,,,,Muss, + 248,Umsatzsteuer der Rechnung,SG52,TAX,,,,,,Muss, + 249,Umsatzsteuer der Rechnung,SG52,TAX,5283,,7,,Steuer,X, + 250,Umsatzsteuer der Rechnung,SG52,TAX,5153,,VAT,,Umsatzsteuer,X, + 251,Umsatzsteuer der Rechnung,SG52,TAX,5278,,,,Zoll-/Steuer-/Gebührenrate,X [902] ∧[930],"[902] Format: Möglicher Wert: ≥ 0 + [930] Format: max. 2 Nachkommastellen" + 252,Umsatzsteuer der Rechnung,SG52,TAX,5305,,S,,Einheitssatz(Standard),X, + 253,Umsatzsteuer der Rechnung,SG52,TAX,5305,,O,,nicht steuerbar,X, + 254,Umsatzsteuer der Rechnung,SG52,TAX,5305,,AE,,Reverse Charge /Steuerschuldnerschaft desLeistungsempfängers,X, + 255,Vorausbezahlter Betrag (steuersatzbezogen),SG52,MOA,,,,,,,[13] Wenn vorausbezahlter Betrag vorliegt + 256,Vorausbezahlter Betrag (steuersatzbezogen),SG52,MOA,5025,,113,,VorausbezahlterBetrag (inkl. USt.),, + 257,Vorausbezahlter Betrag (steuersatzbezogen),SG52,MOA,5004,,,,Geldbetrag,,[930] Format: max. 2 Nachkommastellen + 258,Vorausbezahlte Steuern (steuersatzbezogen),SG52,MOA,,,,,,,[58] Wenn in dieser SG52 MOA+113 vorhanden + 259,Vorausbezahlte Steuern (steuersatzbezogen),SG52,MOA,5025,,115,,VorausbezahlteSteuern (USt.-Anteildes vorausbezahltenBetrages),, + 260,Vorausbezahlte Steuern (steuersatzbezogen),SG52,MOA,5004,,,,Geldbetrag,,[930] Format: max. 2 Nachkommastellen + 261,Besteuerungsgrundlage (steuersatzbezogen),SG52,MOA,,,,,,Muss, + 262,Besteuerungsgrundlage (steuersatzbezogen),SG52,MOA,5025,,125,,Besteuerungsgrundl,X, + 263,Besteuerungsgrundlage (steuersatzbezogen),SG52,MOA,5004,,,,Geldbetrag,X [930],[930] Format: max. 2 Nachkommastellen + 264,Steuerbetrag (steuersatzbezogen),SG52,MOA,,,,,,Muss, + 265,Steuerbetrag (steuersatzbezogen),SG52,MOA,5025,,161,,Steuer-/Gebühren-/Abgabebetrag,X, + 266,Steuerbetrag (steuersatzbezogen),SG52,MOA,5004,,,,Geldbetrag,X [930],[930] Format: max. 2 Nachkommastellen + 267,Nachrichtenende,,UNT,,,,,,Muss, + 268,Nachrichtenende,,UNT,0074,,,,Anzahl der Segmente ineiner Nachricht,X, + 269,Nachrichtenende,,UNT,0062,,,,Nachrichten-Referenznummer,X, + + ''' +# --- +# name: TestCli.test_kohlrahbi_cli_with_valid_arguments[31007] + ''' + ,Segmentname,Segmentgruppe,Segment,Datenelement,Segment ID,Code,Qualifier,Beschreibung,Bedingungsausdruck,Bedingung + 0,Nachrichtenanfang,,UNH,,,,,,Muss, + 1,Nachrichtenanfang,,UNH,0062,,,,Nachrichten-Referenznummer,X, + 2,Nachrichtenanfang,,UNH,0065,,INVOIC,,Rechnung,X, + 3,Nachrichtenanfang,,UNH,0052,,D,,Entwurfs-Version,X, + 4,Nachrichtenanfang,,UNH,0054,,06A,,Ausgabe 2006 - A,X, + 5,Nachrichtenanfang,,UNH,0051,,UN,,UN/CEFACT,X, + 6,Nachrichtenanfang,,UNH,0057,,2.8c,,VersionsnummerderzugrundeliegendenBDEW-Nachrichtenbeschreibung,X, + 7,Rechnungsnummer,,BGM,,,,,,Muss, + 8,Rechnungsnummer,,BGM,1001,,380,,Handelsrechnung,X, + 9,Rechnungsnummer,,BGM,1001,,389,,"Selbst ausgestellteRechnung (engl.:""Self-billed invoice"")",, + 10,Rechnungsnummer,,BGM,1004,,,,Dokumentennummer,X, + 11,Rechnungsnummer,,BGM,1225,,7,,Duplikat,X, + 12,Rechnungsnummer,,BGM,1225,,9,,Original,X, + 13,Nachrichtendatum,,DTM,,,,,,Muss, + 14,Nachrichtendatum,,DTM,2005,,137,,Dokumenten-/Nachrichtendatum/-zeit,X, + 15,Nachrichtendatum,,DTM,2380,,,,"Datum oder Uhrzeit oderZeitspanne, Wert",X [931],[931] Format: ZZZ = +00 + 16,Nachrichtendatum,,DTM,2379,,303,,CCYYMMDDHHMMZZZ,X, + 17,Bearbeitungs-/ Verarbeitungsdatum,,DTM,,,,,,Muss, + 18,Bearbeitungs-/ Verarbeitungsdatum,,DTM,2005,,9,,Bearbeitungs-/Verarbeitungsdatum/-zeit,X, + 19,Bearbeitungs-/ Verarbeitungsdatum,,DTM,2380,,,,"Datum oder Uhrzeit oderZeitspanne, Wert",X [931],[931] Format: ZZZ = +00 + 20,Bearbeitungs-/ Verarbeitungsdatum,,DTM,2379,,303,,CCYYMMDDHHMMZZZ,X, + 21,Abrechnungszeitraum Beginn,,DTM,,,,,,Muss, + 22,Abrechnungszeitraum Beginn,,DTM,2005,,155,,"Rechnungsperiode,Beginndatum",X, + 23,Abrechnungszeitraum Beginn,,DTM,2380,,,,Datum oder Uhrzeit oder,X [UB3], + 24,Abrechnungszeitraum Beginn,,DTM,2379,,303,,CCYYMMDDHHMMZZZ,X, + 25,Abrechnungszeitraum Ende,,DTM,,,,,,Muss, + 26,Abrechnungszeitraum Ende,,DTM,2005,,156,,"Rechnungsperiode,Endedatum",X, + 27,Abrechnungszeitraum Ende,,DTM,2380,,,,"Datum oder Uhrzeit oderZeitspanne, Wert",X [UB3], + 28,Abrechnungszeitraum Ende,,DTM,2379,,303,,CCYYMMDDHHMMZZZ,X, + 29,Beginn Bilanzierung,,DTM,,,,,,,[15] Wenn eine Bilanzierung erfolgt ist + 30,Beginn Bilanzierung,,DTM,2005,,Z11,,BeginndatumBilanzierungzugeordnetePeriode,, + 31,Beginn Bilanzierung,,DTM,2380,,,,"Datum oder Uhrzeit oderZeitspanne, Wert",, + 32,Beginn Bilanzierung,,DTM,2379,,303,,CCYYMMDDHHMMZZZ,, + 33,Ende Netznutzung,,DTM,,,,,,,[16] Wenn eine Netznutzung erfolgt ist + 34,Ende Netznutzung,,DTM,2005,,Z12,,Ende NetznutzungzugeordnetePeriode,, + 35,Ende Netznutzung,,DTM,2380,,,,"Datum oder Uhrzeit oderZeitspanne, Wert",, + 36,Ende Netznutzung,,DTM,2379,,303,,CCYYMMDDHHMMZZZ,, + 37,Rechnungstyp,,IMD,,,,,,Muss, + 38,Rechnungstyp,,IMD,7081,,MMM,,Mehr-/Mindermengenabrechnung,X, + 39,Rechnungstyp,,IMD,7009,,Z06,,Erzeugung,, + 40,Rechnungstyp,,IMD,7009,,Z07,,Verbrauch,, + 41,Meldeinformationen,,FTX,,,,,,Soll [4] ,[4] Wenn Steuerschuldnerschaft des Leistungsempfängers vorliegt + 42,Meldeinformationen,,FTX,4451,,REG,,Meldeinformationen,X, + 43,Meldeinformationen,,FTX,4441,,RCH,,Reverse Chargegemäß §13b UStG /Steuerschuldnerschaft desLeistungsempfängers,X, + 44,Prüfidentifikator,SG1,,,,,,,Muss, + 45,Prüfidentifikator,SG1,RFF,,,,,,Muss, + 46,Prüfidentifikator,SG1,RFF,1153,,Z13,,Prüfidentifikator,X, + 47,Prüfidentifikator,SG1,RFF,1154,,31005,,MMM-Rechnung,, + 48,Prüfidentifikator,SG1,RFF,1154,,31006,,MMM-selbstausgestellteRechnung,, + 49,Prüfidentifikator,SG1,RFF,1154,,31007,,Aggregierte MMM-Rechnung,X, + 50,Prüfidentifikator,SG1,RFF,1154,,31008,,Aggregierte MMM-selbst ausgestellteRechnung,, + 51,Referenz auf Nummer des zugehörigen Dokuments,SG1,,,,,,,Muss [17],[17] Wenn DTM+Z11 vorhanden + 52,Referenz auf Nummer des zugehörigen Dokuments,SG1,RFF,,,,,,Muss, + 53,Referenz auf Nummer des zugehörigen Dokuments,SG1,RFF,1153,,ACE,,Nummer deszugehörigenDokuments,X, + 54,Referenz auf Nummer des zugehörigen Dokuments,SG1,RFF,1154,,,,"Referenz, Identifikation",X [507],"[502] Hinweis: Dokumentennummer der Bilanzierungs- MSCONS + [507] Hinweis: Dokumentennummer der SSQNOT" + 55,Name und Anschrift des Nachrichtensenders,SG2,,,,,,,Muss, + 56,Name und Anschrift des Nachrichtensenders,SG2,NAD,,,,,,Muss, + 57,Name und Anschrift des Nachrichtensenders,SG2,NAD,3035,,MS,,Dokumenten-/Nachrichtenaussteller bzw. -absender,X, + 58,Name und Anschrift des Nachrichtensenders,SG2,NAD,3039,,,,MP-ID,X, + 59,Name und Anschrift des Nachrichtensenders,SG2,NAD,3055,,9,,GS1,X, + 60,Name und Anschrift des Nachrichtensenders,SG2,NAD,3055,,293,,"DE, BDEW(Bundesverband derEnergie- undWasserwirtschafte.V.)",, + 61,Name und Anschrift des Nachrichtensenders,SG2,NAD,3055,,332,,"DE, DVGW Service &Consult GmbH",X, + 62,Name und Anschrift des Nachrichtensenders,SG2,NAD,3036,,,,Beteiligter,X, + 63,Name und Anschrift des Nachrichtensenders,SG2,NAD,3045,,Z01,,Struktur vonPersonennamen,X, + 64,Name und Anschrift des Nachrichtensenders,SG2,NAD,3045,,Z02,,Struktur derFirmenbezeichnung,X, + 65,Name und Anschrift des Nachrichtensenders,SG2,NAD,3042,,,,Straße und Hausnummeroder Postfach,S [7],[7] Sofern keine Großkundenpostleitza hl verwendet wird + 66,Name und Anschrift des Nachrichtensenders,SG2,NAD,3164,,,,Ort,M, + 67,Name und Anschrift des Nachrichtensenders,SG2,NAD,3251,,,,"Postleitzahl, Code",X, + 68,Name und Anschrift des Nachrichtensenders,SG2,NAD,3207,,,,"Ländername, Code",X, + 69,"Steuernummer, Umsatzsteuernummer",SG3,,,,,,,Muss, + 70,"Steuernummer, Umsatzsteuernummer",SG3,RFF,,,,,,Muss, + 71,"Steuernummer, Umsatzsteuernummer",SG3,RFF,1153,,VA,,Umsatzsteuernummer,X, + 72,"Steuernummer, Umsatzsteuernummer",SG3,RFF,1153,,FC,,Steuernummer,X [6],[6] Wenn NAD+MR DE3207 = „DE“ + 73,"Steuernummer, Umsatzsteuernummer",SG3,RFF,1154,,,,"Referenz, Identifikation",X, + 74,Ansprechpartner,SG5,,,,,,,Kann, + 75,Ansprechpartner,SG5,CTA,,,,,,Muss, + 76,Ansprechpartner,SG5,CTA,3139,,IC,,Informationskontakt,X, + 77,Ansprechpartner,SG5,CTA,3412,,,,Kontakt,X, + 78,Kommunikationsverbindu ng,SG5,COM,,,,,,Muss, + 79,Kommunikationsverbindu ng,SG5,COM,3148,,,,"Kommunikationsadresse,Identifikation",X (([939][74]) ∨([940][75]))∧ [524],"[74] wenn im DE3155 in demselben COM der Code EM vorhanden ist + [75] wenn im DE3155 in demselben COM der Code TE / FX / AJ / AL vorhanden ist + [524] Hinweis: Es darf nur eine Information im DE3148 übermittelt werden + [939] Format: Die Zeichenkette muss die Zeichen @ und . enthalten + [940] Format: Die Zeichenkette muss mit dem Zeichen + beginnen und danach dürfen nur noch" + 80,Kommunikationsverbindu ng,SG5,COM,3155,,EM,,Elektronische Post,X [1P0..1], + 81,Kommunikationsverbindu ng,SG5,COM,3155,,FX,,Telefax,X [1P0..1], + 82,Kommunikationsverbindu ng,SG5,COM,3155,,TE,,Telefon,X [1P0..1], + 83,Kommunikationsverbindu ng,SG5,COM,3155,,AJ,,weiteres Telefon,X [1P0..1], + 84,Kommunikationsverbindu ng,SG5,COM,3155,,AL,,Handy,X [1P0..1], + 85,Name und Anschrift des Nachrichtenempfängers,SG2,,,,,,,Muss, + 86,Name und Anschrift des Nachrichtenempfängers,SG2,NAD,,,,,,Muss, + 87,Name und Anschrift des Nachrichtenempfängers,SG2,NAD,3035,,MR,,Nachrichtenempfänger,X, + 88,Name und Anschrift des Nachrichtenempfängers,SG2,NAD,3039,,,,MP-ID,X, + 89,Name und Anschrift des Nachrichtenempfängers,SG2,NAD,3055,,9,,GS1,X, + 90,Name und Anschrift des Nachrichtenempfängers,SG2,NAD,3055,,293,,"DE, BDEW(Bundesverband derEnergie- undWasserwirtschafte.V.)",, + 91,Name und Anschrift des Nachrichtenempfängers,SG2,NAD,3055,,332,,"DE, DVGW Service &Consult GmbH",X, + 92,Name und Anschrift des Nachrichtenempfängers,SG2,NAD,3036,,,,Beteiligter,X, + 93,Name und Anschrift des Nachrichtenempfängers,SG2,NAD,3045,,Z01,,Struktur vonPersonennamen,X, + 94,Name und Anschrift des Nachrichtenempfängers,SG2,NAD,3045,,Z02,,Struktur derFirmenbezeichnung,X, + 95,Name und Anschrift des Nachrichtenempfängers,SG2,NAD,3042,,,,Straße und Hausnummeroder Postfach,S [7],[7] Sofern keine Großkundenpostleitza hl verwendet wird + 96,Name und Anschrift des Nachrichtenempfängers,SG2,NAD,3164,,,,Ort,M, + 97,Name und Anschrift des Nachrichtenempfängers,SG2,NAD,3251,,,,"Postleitzahl, Code",X, + 98,Name und Anschrift des Nachrichtenempfängers,SG2,NAD,3207,,,,"Ländername, Code",X, + 99,"Steuernummer, Umsatzsteuernummer",SG3,,,,,,,MussSoll [4],"[4] Wenn Steuerschuldnerschaft des Leistungsempfängers vorliegt + [5] Wenn NAD+MR DE3207 <> „DE“" + 100,"Steuernummer, Umsatzsteuernummer",SG3,RFF,,,,,,Muss, + 101,"Steuernummer, Umsatzsteuernummer",SG3,RFF,1153,,VA,,Umsatzsteuernummer,X, + 102,"Steuernummer, Umsatzsteuernummer",SG3,RFF,1153,,FC,,Steuernummer,X [6],[6] Wenn NAD+MR DE3207 = „DE“ + 103,"Steuernummer, Umsatzsteuernummer",SG3,RFF,1154,,,,"Referenz, Identifikation",X, + 104,Adresse der Leistungserbringung,SG2,,,,,,,, + 105,Adresse der Leistungserbringung,SG2,NAD,,,,,,, + 106,Adresse der Leistungserbringung,SG2,NAD,3035,,DP,,Lieferanschrift,, + 107,Adresse der Leistungserbringung,SG2,NAD,3124,,,,Zusatzinformation zurIdentifizierung,, + 108,Adresse der Leistungserbringung,SG2,NAD,3042,,,,Straße und Hausnummeroder Postfach,,"[22] Wenn vorhanden + [23] Wenn im selben NAD DE3124 nicht vorhanden" + 109,Adresse der Leistungserbringung,SG2,NAD,3164,,,,Ort,, + 110,Adresse der Leistungserbringung,SG2,NAD,3251,,,,"Postleitzahl, Code",, + 111,Adresse der Leistungserbringung,SG2,NAD,3207,,,,"Ländername, Code",, + 112,Meldepunkt,SG2,LOC,,,,,,, + 113,Meldepunkt,SG2,LOC,3227,,172,,Meldepunkt,, + 114,Meldepunkt,SG2,LOC,3225,,,,"Ortsangabe, Nummer",,"[509] Hinweis: Verwendung der ID der Marktlokation + [950] Format: Marktlokations-ID" + 115,Netzbetreiberkontonum mer,SG2,,,,,,,Muss, + 116,Netzbetreiberkontonum mer,SG2,NAD,,,,,,Muss, + 117,Netzbetreiberkontonum mer,SG2,NAD,3035,,ZSH,,Netzkonto,X, + 118,Netzbetreiberkontonum mer,SG2,NAD,3039,,,,"Beteiligter, Identifikation",X, + 119,Währungsangaben,SG7,,,,,,,Muss, + 120,Währungsangaben,SG7,CUX,,,,,,Muss, + 121,Währungsangaben,SG7,CUX,6347,,2,,Referenzwährung,X, + 122,Währungsangaben,SG7,CUX,6345,,EUR,,Euro,X, + 123,Währungsangaben,SG7,CUX,6343,,4,,Währung derRechnung,X, + 124,Zahlungsbedingungen,SG8,,,,,,,Muss, + 125,Zahlungsbedingungen,SG8,PYT,,,,,,Muss, + 126,Zahlungsbedingungen,SG8,PYT,4279,,3,,Fixdatum,X, + 127,Fälligkeitsdatum,SG8,DTM,,,,,,Muss, + 128,Fälligkeitsdatum,SG8,DTM,2005,,265,,Fälligkeitsdatum,X, + 129,Fälligkeitsdatum,SG8,DTM,2380,,,,"Datum oder Uhrzeit oderZeitspanne, Wert",X [UB1] ∧[24],"[20] Wenn fälliger Betrag (SG50 MOA+9) ≥ 0 + [21] Wenn fälliger Betrag (SG50 MOA+9) < 0" + 130,Fälligkeitsdatum,SG8,DTM,2379,,303,,CCYYMMDDHHMMZZZ,X, + 131,Positionsdaten,SG26,,,,,,,Muss, + 132,Positionsdaten,SG26,LIN,,,,,,Muss, + 133,Positionsdaten,SG26,LIN,1082,,,,Positionsnummer,X [911],"[911] Format: Mögliche Werte: 1 bis n, je Nachricht oder Segmentgruppe bei 1 beginnend und fortlaufend aufsteigend" + 134,Positionsdaten,SG26,LIN,7140,,,,Produkt-/Leistungsnummer,X [40],"[40] Es sind nur die Artikelnummern erlaubt, die in der Codeliste der Artikelnummern und Artikel-ID mit dem entsprechenden Prüfidentifikator versehen sind oder Artikel-ID aus der Codeliste der Artikelnummern und Artikel-ID." + 135,Positionsdaten,SG26,LIN,7143,,Z01,,Artikelnummer,X, + 136,energetische Mengenangaben,SG26,QTY,,,,,,Muss, + 137,energetische Mengenangaben,SG26,QTY,6063,,47,,Berechnete(fakturierte) Menge,X, + 138,energetische Mengenangaben,SG26,QTY,6060,,,,Menge,X [902] ∧[937],"[902] Format: Möglicher Wert: ≥ 0 + [937] Format: keine Nachkommastelle" + 139,energetische Mengenangaben,SG26,QTY,6411,,KWH,,Kilowattstunde,X, + 140,Korrekturfaktor,SG26,QTY,,,,,,,[14] Wenn in selben SG26 LIN DE7140 = + 141,Korrekturfaktor,SG26,QTY,6063,,Z17,,Korrekturfaktor,, + 142,Korrekturfaktor,SG26,QTY,6060,,,,Menge,,[927] Format: Möglicher Wert: -1 + 143,Positionsbezogener Abrechnungszeitraum Beginn,SG26,DTM,,,,,,Muss, + 144,Positionsbezogener Abrechnungszeitraum Beginn,SG26,DTM,2005,,155,,"Rechnungsperiode,Beginndatum",X, + 145,Positionsbezogener Abrechnungszeitraum Beginn,SG26,DTM,2380,,,,"Datum oder Uhrzeit oderZeitspanne, Wert",X [UB2], + 146,Positionsbezogener Abrechnungszeitraum Beginn,SG26,DTM,2379,,303,,CCYYMMDDHHMMZZZ,X, + 147,Positionsbezogener Abrechnungszeitraum Ende,SG26,DTM,,,,,,Muss, + 148,Positionsbezogener Abrechnungszeitraum Ende,SG26,DTM,2005,,156,,"Rechnungsperiode,Endedatum",X, + 149,Positionsbezogener Abrechnungszeitraum Ende,SG26,DTM,2380,,,,"Datum oder Uhrzeit oderZeitspanne, Wert",X [UB2], + 150,Positionsbezogener Abrechnungszeitraum Ende,SG26,DTM,2379,,303,,CCYYMMDDHHMMZZZ,X, + 151,Positionsnettobetrag,SG27,,,,,,,Muss, + 152,Positionsnettobetrag,SG27,MOA,,,,,,Muss, + 153,Positionsnettobetrag,SG27,MOA,5025,,203,,Positionsbetrag(ohne USt.),X, + 154,Positionsnettobetrag,SG27,MOA,5004,,,,Geldbetrag,X [930],[930] Format: max. 2 Nachkommastellen + 155,Preis,SG29,,,,,,,Muss, + 156,Preis,SG29,PRI,,,,,,Muss, + 157,Preis,SG29,PRI,5125,,CAL,,Berechnungspreis,X, + 158,Preis,SG29,PRI,5118,,,,"Preis, Betrag",X [912],[912] Format: max. 6 Nachkommastellen + 159,Umsatzsteuer der Position,SG34,,,,,,,Muss, + 160,Umsatzsteuer der Position,SG34,TAX,,,,,,Muss, + 161,Umsatzsteuer der Position,SG34,TAX,5283,,7,,Steuer,X, + 162,Umsatzsteuer der Position,SG34,TAX,5153,,VAT,,Umsatzsteuer,X, + 163,Umsatzsteuer der Position,SG34,TAX,5278,,,,Zoll-/Steuer-/Gebührenrate,X [902] ∧,[902] Format: + 164,Umsatzsteuer der Position,SG34,TAX,5305,,S,,Einheitssatz(Standard),X, + 165,Umsatzsteuer der Position,SG34,TAX,5305,,O,,nicht steuerbar,X, + 166,Umsatzsteuer der Position,SG34,TAX,5305,,AE,,Reverse Charge /Steuerschuldnerschaft desLeistungsempfängers,X, + 167,Abschnitts- Kontrollsegment,,UNS,,,,,,Muss, + 168,Abschnitts- Kontrollsegment,,UNS,0081,,S,,Trennung vonPositions- undSummenteil,X, + 169,Rechnungsbetrag,SG50,,,,,,,Muss, + 170,Rechnungsbetrag,SG50,MOA,,,,,,Muss, + 171,Rechnungsbetrag,SG50,MOA,5025,,77,,Rechnungsbetrag,X, + 172,Rechnungsbetrag,SG50,MOA,5004,,,,Geldbetrag,X [930][503],"[503] Hinweis: Ein positiver Betrag ist eine Forderung des Rechnungsstellers. + [504] Hinweis: Ein positiver Betrag ist eine Forderung des Rechnungsempfängers . + [930] Format: max. 2 Nachkommastellen" + 173,Fälliger Betrag,SG50,,,,,,,Muss, + 174,Fälliger Betrag,SG50,MOA,,,,,,Muss, + 175,Fälliger Betrag,SG50,MOA,5025,,9,,Fälliger Betrag (inkl.USt.),X, + 176,Fälliger Betrag,SG50,MOA,5004,,,,Geldbetrag,X [930],[930] Format: max. 2 Nachkommastellen + 177,Umsatzsteuer der Rechnung,SG52,,,,,,,Muss, + 178,Umsatzsteuer der Rechnung,SG52,TAX,,,,,,Muss, + 179,Umsatzsteuer der Rechnung,SG52,TAX,5283,,7,,Steuer,X, + 180,Umsatzsteuer der Rechnung,SG52,TAX,5153,,VAT,,Umsatzsteuer,X, + 181,Umsatzsteuer der Rechnung,SG52,TAX,5278,,,,Zoll-/Steuer-/Gebührenrate,X [902] ∧[930],"[902] Format: Möglicher Wert: ≥ 0 + [930] Format: max. 2 Nachkommastellen" + 182,Umsatzsteuer der Rechnung,SG52,TAX,5305,,S,,Einheitssatz(Standard),X, + 183,Umsatzsteuer der Rechnung,SG52,TAX,5305,,O,,nicht steuerbar,X, + 184,Umsatzsteuer der Rechnung,SG52,TAX,5305,,AE,,Reverse Charge /Steuerschuldnerschaft desLeistungsempfängers,X, + 185,Besteuerungsgrundlage (steuersatzbezogen),SG52,MOA,,,,,,Muss, + 186,Besteuerungsgrundlage (steuersatzbezogen),SG52,MOA,5025,,125,,Besteuerungsgrundlage,X, + 187,Besteuerungsgrundlage (steuersatzbezogen),SG52,MOA,5004,,,,Geldbetrag,X [930],[930] Format: max. 2 Nachkommastellen + 188,Steuerbetrag (steuersatzbezogen),SG52,MOA,,,,,,Muss, + 189,Steuerbetrag (steuersatzbezogen),SG52,MOA,5025,,161,,Steuer-/Gebühren-/Abgabebetrag,X, + 190,Steuerbetrag (steuersatzbezogen),SG52,MOA,5004,,,,Geldbetrag,X [930],[930] Format: max. 2 Nachkommastellen + 191,Nachrichtenende,,UNT,,,,,,Muss, + 192,Nachrichtenende,,UNT,0074,,,,Anzahl der Segmente ineiner Nachricht,X, + 193,Nachrichtenende,,UNT,0062,,,,Nachrichten-Referenznummer,X, + + ''' +# --- +# name: TestCli.test_kohlrahbi_cli_with_valid_arguments[31011] + ''' + ,Segmentname,Segmentgruppe,Segment,Datenelement,Segment ID,Code,Qualifier,Beschreibung,Bedingungsausdruck,Bedingung + 0,Nachrichtenanfang,,UNH,,,,,,Muss, + 1,Nachrichtenanfang,,UNH,0062,,,,Nachrichten-Referenznummer,X, + 2,Nachrichtenanfang,,UNH,0065,,INVOIC,,Rechnung,X, + 3,Nachrichtenanfang,,UNH,0052,,D,,Entwurfs-Version,X, + 4,Nachrichtenanfang,,UNH,0054,,06A,,Ausgabe 2006 - A,X, + 5,Nachrichtenanfang,,UNH,0051,,UN,,UN/CEFACT,X, + 6,Nachrichtenanfang,,UNH,0057,,2.8c,,Versionsnummer derzugrundeliegendenBDEW-Nachrichtenbeschreibung,X, + 7,Rechnungsnummer,,BGM,,,,,,Muss, + 8,Rechnungsnummer,,BGM,1001,,380,,Handelsrechnung,X, + 9,Rechnungsnummer,,BGM,1004,,,,Dokumentennummer,X, + 10,Rechnungsnummer,,BGM,1225,,,,,79, + 11,Nachrichtendatum,,DTM,,,,,,Muss, + 12,Nachrichtendatum,,DTM,2005,,137,,Dokumenten-/Nachrichtendatum/-zeit,X, + 13,Nachrichtendatum,,DTM,2380,,,,"Datum oder Uhrzeit oderZeitspanne, Wert",X [931],[931] Format: ZZZ = +00 + 14,Nachrichtendatum,,DTM,2379,,303,,CCYYMMDDHHMMZZZ,X, + 15,Bearbeitungs-/ Verarbeitungsdatum,,DTM,,,,,,Muss, + 16,Bearbeitungs-/ Verarbeitungsdatum,,DTM,2005,,9,,Bearbeitungs-/Verarbeitungsdatum/-zeit,X, + 17,Bearbeitungs-/ Verarbeitungsdatum,,DTM,2380,,,,"Datum oder Uhrzeit oderZeitspanne, Wert",X [931],[931] Format: ZZZ = +00 + 18,Bearbeitungs-/ Verarbeitungsdatum,,DTM,2379,,303,,CCYYMMDDHHMMZZZ,X, + 19,Abrechnungszeitraum Beginn,,DTM,,,,,,Muss [53],[53] Wenn IMD++Z45 vorhanden + 20,Abrechnungszeitraum Beginn,,DTM,2005,,155,,"Rechnungsperiode,Beginndatum",X, + 21,Abrechnungszeitraum Beginn,,DTM,2380,,,,"Datum oder Uhrzeit oderZeitspanne, Wert",X [UB3], + 22,Abrechnungszeitraum Beginn,,DTM,2379,,303,,CCYYMMDDHHMMZZZ,X, + 23,Abrechnungszeitraum Ende,,DTM,,,,,,Muss [53],[53] Wenn IMD++Z45 vorhanden + 24,Abrechnungszeitraum Ende,,DTM,2005,,156,,"Rechnungsperiode,Endedatum",X, + 25,Abrechnungszeitraum Ende,,DTM,2380,,,,"Datum oder Uhrzeit oderZeitspanne, Wert",X [UB3], + 26,Abrechnungszeitraum Ende,,DTM,2379,,303,,CCYYMMDDHHMMZZZ,X, + 27,Ausführungsdatum,,DTM,,,,,,Muss [47],[47] Wenn IMD++Z43 vorhanden + 28,Ausführungsdatum,,DTM,2005,,203,,Ausführungsdatum/-zeit,X, + 29,Ausführungsdatum,,DTM,2380,,,,"Datum oder Uhrzeit oderZeitspanne, Wert",X [518],[518] Hinweis: Im Fall der Stornierung des Auftrags der Unterbrechung: Der Tag an dem der NB die Stornierung empfangen hat Bei erfolgreicher Sperrung: Tag der durchgeführten Sperrung Bei erfolgloser Sperrung: Letzter Sperrversuchstag + 30,Ausführungsdatum,,DTM,2379,,102,,CCYYMMDD,X, + 31,Rechnungstyp,,IMD,,,,,,Muss, + 32,Rechnungstyp,,IMD,7081,,Z43,,Rechnung für Sperren undWiederinbetriebnahme,X, + 33,Rechnungstyp,,IMD,7081,,Z44,,Verzugskostenrechnung,X, + 34,Rechnungstyp,,IMD,7081,,Z45,,Blindarbeitrechnung,X [492],[492] Wenn MP-ID in NAD+MR (Nachrichtenempfänger) aus Sparte Strom + 35,Meldeinformationen,,FTX,,,,,,Soll [4] ,[4] Wenn Steuerschuldnerschaft des Leistungsempfängers vorliegt + 36,Meldeinformationen,,FTX,4451,,,,,REG, + 37,Meldeinformationen,,FTX,4441,,RCH,,Reverse Charge gemäߧ13b UStG /Steuerschuldnerschaft desLeistungsempfängers,X, + 38,Prüfidentifikator,SG1,,,,,,,Muss, + 39,Prüfidentifikator,SG1,RFF,,,,,,Muss, + 40,Prüfidentifikator,SG1,RFF,1153,,Z13,,Prüfidentifikator,X, + 41,Prüfidentifikator,SG1,RFF,1154,,31011,,Rechnung sonstige Leistung,X, + 42,Referenz auf Ursprungsrechnungsnumm er,SG1,,,,,,,Muss [48],[48] Wenn IMD++Z44 vorhanden + 43,Referenz auf Ursprungsrechnungsnumm er,SG1,RFF,,,,,,Muss, + 44,Referenz auf Ursprungsrechnungsnumm er,SG1,RFF,1153,,OI,,Ursprungsrechnungsnummer,X [521],"[521] Hinweis: BGM DE1004 aus der INVOIC-Nachricht, für die Verzugskosten erhoben werden" + 45,Referenz auf Ursprungsrechnungsnumm er,SG1,RFF,1154,,,,"Referenz, Identifikation",X, + 46,Referenzdatum,SG1,DTM,,,,,,Muss, + 47,Referenzdatum,SG1,DTM,2005,,171,,Referenzdatum/-zeit,X, + 48,Referenzdatum,SG1,DTM,2380,,,,"Datum oder Uhrzeit oderZeitspanne, Wert",X [931],[931] Format: ZZZ = +00 + 49,Referenzdatum,SG1,DTM,2379,,303,,CCYYMMDDHHMMZZZ,X, + 50,Referenz auf Nummer des zugehörigen Dokuments,SG1,,,,,,,Muss [47],[47] Wenn IMD++Z43 vorhanden + 51,Referenz auf Nummer des zugehörigen Dokuments,SG1,RFF,,,,,,Muss, + 52,Referenz auf Nummer des zugehörigen Dokuments,SG1,RFF,1153,,ACE,,Nummer des zugehörigen,X, + 53,Referenz auf Nummer des zugehörigen Dokuments,SG1,RFF,1154,,,,"Referenz, Identifikation",X [501],[501] Hinweis: Dokumentennummer der ORDERS + 54,Name und Anschrift des Nachrichtensenders,SG2,,,,,,,Muss, + 55,Name und Anschrift des Nachrichtensenders,SG2,NAD,,,,,,Muss, + 56,Name und Anschrift des Nachrichtensenders,SG2,NAD,3035,,Nachrichtenaussteller bzw.-absender,,,MS, + 57,Name und Anschrift des Nachrichtensenders,SG2,NAD,3039,,,,MP-ID,X, + 58,Name und Anschrift des Nachrichtensenders,SG2,NAD,3055,,9,,GS1,X, + 59,Name und Anschrift des Nachrichtensenders,SG2,NAD,3055,,293,,"DE, BDEW (Bundesverbandder Energie- undWasserwirtschaft e.V.)",X, + 60,Name und Anschrift des Nachrichtensenders,SG2,NAD,3055,,332,,"DE, DVGW Service &Consult GmbH",X, + 61,Name und Anschrift des Nachrichtensenders,SG2,NAD,3036,,,,Beteiligter,X, + 62,Name und Anschrift des Nachrichtensenders,SG2,NAD,3045,,Z01,,Struktur vonPersonennamen,X, + 63,Name und Anschrift des Nachrichtensenders,SG2,NAD,3045,,Z02,,Struktur derFirmenbezeichnung,X, + 64,Name und Anschrift des Nachrichtensenders,SG2,NAD,3042,,,,Straße und Hausnummer oderPostfach,S [7],[7] Sofern keine Großkundenpostleitzahl verwendet wird + 65,Name und Anschrift des Nachrichtensenders,SG2,NAD,3164,,,,Ort,M, + 66,Name und Anschrift des Nachrichtensenders,SG2,NAD,3251,,,,"Postleitzahl, Code",X, + 67,Name und Anschrift des Nachrichtensenders,SG2,NAD,3207,,,,"Ländername, Code",X, + 68,"Steuernummer, Umsatzsteuernummer",SG3,,,,,,,Muss, + 69,"Steuernummer, Umsatzsteuernummer",SG3,RFF,,,,,,Muss, + 70,"Steuernummer, Umsatzsteuernummer",SG3,RFF,1153,,VA,,Umsatzsteuernummer,X, + 71,"Steuernummer, Umsatzsteuernummer",SG3,RFF,1153,,FC,,Steuernummer,X [6],[6] Wenn NAD+MR DE3207 = „DE“ + 72,"Steuernummer, Umsatzsteuernummer",SG3,RFF,1154,,,,"Referenz, Identifikation",X, + 73,Ansprechpartner,SG5,,,,,,,Kann, + 74,Ansprechpartner,SG5,CTA,,,,,,Muss, + 75,Ansprechpartner,SG5,CTA,3139,,,,,IC, + 76,Ansprechpartner,SG5,CTA,3412,,,,Kontakt,X, + 77,Kommunikationsverbindung,SG5,COM,,,,,,Muss, + 78,Kommunikationsverbindung,SG5,COM,3148,,,,"Kommunikationsadresse,Identifikation",X (([939][74]) ∨ ([940][75])) ∧ [524],"[74] wenn im DE3155 in demselben COM der Code EM vorhanden ist + [75] wenn im DE3155 in demselben COM der Code TE / FX / AJ / AL vorhanden ist + [524] Hinweis: Es darf nur eine Information im DE3148 übermittelt werden" + 79,Kommunikationsverbindung,SG5,COM,3155,,EM,,Elektronische Post,X [1P0..1], + 80,Kommunikationsverbindung,SG5,COM,3155,,FX,,Telefax,X [1P0..1], + 81,Kommunikationsverbindung,SG5,COM,3155,,TE,,Telefon,X [1P0..1], + 82,Kommunikationsverbindung,SG5,COM,3155,,AJ,,weiteres Telefon,X [1P0..1], + 83,Kommunikationsverbindung,SG5,COM,3155,,AL,,Handy,X [1P0..1], + 84,Name und Anschrift des Nachrichtenempfängers,SG2,,,,,,,Muss, + 85,Name und Anschrift des Nachrichtenempfängers,SG2,NAD,,,,,,Muss, + 86,Name und Anschrift des Nachrichtenempfängers,SG2,NAD,3035,,,,,MR, + 87,Name und Anschrift des Nachrichtenempfängers,SG2,NAD,3039,,,,MP-ID,X, + 88,Name und Anschrift des Nachrichtenempfängers,SG2,NAD,3055,,9,,GS1,X, + 89,Name und Anschrift des Nachrichtenempfängers,SG2,NAD,3055,,293,,"DE, BDEW (Bundesverbandder Energie- undWasserwirtschaft e.V.)",X, + 90,Name und Anschrift des Nachrichtenempfängers,SG2,NAD,3055,,332,,"DE, DVGW Service &Consult GmbH",X, + 91,Name und Anschrift des Nachrichtenempfängers,SG2,NAD,3036,,,,Beteiligter,X, + 92,Name und Anschrift des Nachrichtenempfängers,SG2,NAD,3045,,Z01,,Struktur vonPersonennamen,X, + 93,Name und Anschrift des Nachrichtenempfängers,SG2,NAD,3045,,Z02,,Struktur derFirmenbezeichnung,X, + 94,Name und Anschrift des Nachrichtenempfängers,SG2,NAD,3042,,,,Straße und Hausnummer oderPostfach,S [7],[7] Sofern keine Großkundenpostleitzahl verwendet wird + 95,Name und Anschrift des Nachrichtenempfängers,SG2,NAD,3164,,,,Ort,M, + 96,Name und Anschrift des Nachrichtenempfängers,SG2,NAD,3251,,,,"Postleitzahl, Code",X, + 97,Name und Anschrift des Nachrichtenempfängers,SG2,NAD,3207,,,,"Ländername, Code",X, + 98,"Steuernummer, Umsatzsteuernummer",SG3,,,,,,,Muss [5]Soll [4],"[4] Wenn Steuerschuldnerschaft des Leistungsempfängers vorliegt + [5] Wenn NAD+MR DE3207 <> „DE“" + 99,"Steuernummer, Umsatzsteuernummer",SG3,RFF,,,,,,Muss, + 100,"Steuernummer, Umsatzsteuernummer",SG3,RFF,1153,,VA,,Umsatzsteuernummer,X, + 101,"Steuernummer, Umsatzsteuernummer",SG3,RFF,1153,,FC,,Steuernummer,X [6],[6] Wenn NAD+MR DE3207 = „DE“ + 102,"Steuernummer, Umsatzsteuernummer",SG3,RFF,1154,,,,"Referenz, Identifikation",X, + 103,Adresse der Leistungserbringung,SG2,,,,,,,Muss, + 104,Adresse der Leistungserbringung,SG2,NAD,,,,,,Muss, + 105,Adresse der Leistungserbringung,SG2,NAD,3035,,,,,DP, + 106,Adresse der Leistungserbringung,SG2,NAD,3124,,,,Zusatzinformation zurIdentifizierung,K, + 107,Adresse der Leistungserbringung,SG2,NAD,3042,,,,Straße und Hausnummer oder,S [22],[22] Wenn vorhanden + 108,Adresse der Leistungserbringung,SG2,NAD,3164,,,,Ort,M, + 109,Adresse der Leistungserbringung,SG2,NAD,3251,,,,"Postleitzahl, Code",X, + 110,Adresse der Leistungserbringung,SG2,NAD,3207,,,,"Ländername, Code",X, + 111,Meldepunkt,SG2,LOC,,,,,,Muss, + 112,Meldepunkt,SG2,LOC,3227,,,,,172, + 113,Meldepunkt,SG2,LOC,3225,,,,"Ortsangabe, Nummer",X ([950] [509] ∧ ([64] V[70])) V ([960] [522] ∧ [71]∧ [53]),"[53] Wenn IMD++Z45 vorhanden + [64] Wenn DTM+156 (Abrechnungszeitraum Ende) ≤ 1. 1.2024 0:00 gesetzlicher deutscher Zeit + [70] Wenn IMD++Z45 nicht vorhanden + [71] Wenn DTM+155 (Abrechnungszeitraum Beginn) ≥ 1.1.2024 0:00 gesetzlicher deutscher Zeit + [509] Hinweis: Verwendung der ID der Marktlokation + [522] Hinweis: Verwendung der ID der Netzlokation + [950] Format: Marktlokations-ID + [960] Format: Netzlokations-ID" + 114,Währungsangaben,SG7,,,,,,,Muss, + 115,Währungsangaben,SG7,CUX,,,,,,Muss, + 116,Währungsangaben,SG7,CUX,6347,,2,,Referenzwährung,X, + 117,Währungsangaben,SG7,CUX,6345,,EUR,,Euro,X, + 118,Währungsangaben,SG7,CUX,6343,,4,,Währung der Rechnung,X, + 119,Zahlungsbedingungen,SG8,,,,,,,Muss, + 120,Zahlungsbedingungen,SG8,PYT,,,,,,Muss, + 121,Zahlungsbedingungen,SG8,PYT,4279,,,,,3, + 122,Fälligkeitsdatum,SG8,DTM,,,,,,Muss, + 123,Fälligkeitsdatum,SG8,DTM,2005,,265,,Fälligkeitsdatum,X, + 124,Fälligkeitsdatum,SG8,DTM,2380,,,,"Datum oder Uhrzeit oderZeitspanne, Wert",X [UB1], + 125,Fälligkeitsdatum,SG8,DTM,2379,,303,,CCYYMMDDHHMMZZZ,X, + 126,Positionsdaten,SG26,,,,,,,Muss, + 127,Positionsdaten,SG26,LIN,,,,,,Muss, + 128,Positionsdaten,SG26,LIN,1082,,,,Positionsnummer,X [911],"[911] Format: Mögliche Werte: 1 bis n, je Nachricht oder Segmentgruppe bei 1 beginnend und fortlaufend aufsteigend" + 129,Positionsdaten,SG26,LIN,7140,,,,Produkt-/Leistungsnummer,X [520],[520] Hinweis: Es sind nur die + 130,Positionsdaten,SG26,LIN,7143,,Z09,,Artikel-ID,X, + 131,energetische Mengenangaben,SG26,QTY,,,,,,Muss, + 132,energetische Mengenangaben,SG26,QTY,6063,,47,,Berechnete (fakturierte)Menge,X, + 133,energetische Mengenangaben,SG26,QTY,6060,,,,Menge,X [902] ∧ [937],"[902] Format: Möglicher Wert: ≥ 0 + [937] Format: keine Nachkommastelle" + 134,energetische Mengenangaben,SG26,QTY,6411,,K3,,kilovolt ampere reactivehour,X, + 135,energetische Mengenangaben,SG26,QTY,6411,,H87,,Stück,X, + 136,Positionsbezogener Abrechnungszeitraum Beginn,SG26,DTM,,,,,,Muss [53],[53] Wenn IMD++Z45 vorhanden + 137,Positionsbezogener Abrechnungszeitraum Beginn,SG26,DTM,2005,,155,,"Rechnungsperiode,Beginndatum",X, + 138,Positionsbezogener Abrechnungszeitraum Beginn,SG26,DTM,2380,,,,"Datum oder Uhrzeit oderZeitspanne, Wert",X [UB1], + 139,Positionsbezogener Abrechnungszeitraum Beginn,SG26,DTM,2379,,303,,CCYYMMDDHHMMZZZ,X, + 140,Positionsbezogener Abrechnungszeitraum Ende,SG26,DTM,,,,,,Muss [53],[53] Wenn IMD++Z45 vorhanden + 141,Positionsbezogener Abrechnungszeitraum Ende,SG26,DTM,2005,,156,,"Rechnungsperiode,Endedatum",X, + 142,Positionsbezogener Abrechnungszeitraum Ende,SG26,DTM,2380,,,,"Datum oder Uhrzeit oderZeitspanne, Wert",X [UB1], + 143,Positionsbezogener Abrechnungszeitraum Ende,SG26,DTM,2379,,303,,CCYYMMDDHHMMZZZ,X, + 144,Ausführungsdatum,SG26,DTM,,,,,,Muss [47],[47] Wenn IMD++Z43 vorhanden + 145,Ausführungsdatum,SG26,DTM,2005,,203,,Ausführungsdatum/-zeit,X, + 146,Ausführungsdatum,SG26,DTM,2380,,,,"Datum oder Uhrzeit oderZeitspanne, Wert",X [518],[518] Hinweis: Im Fall der Stornierung des Auftrags der Unterbrechung: Der Tag an dem der NB die Stornierung empfangen hat Bei erfolgreicher Sperrung: Tag der durchgeführten Sperrung Bei erfolgloser Sperrung: Letzter Sperrversuchstag + 147,Ausführungsdatum,SG26,DTM,2379,,102,,CCYYMMDD,X, + 148,Positionsnettobetrag,SG27,,,,,,,Muss, + 149,Positionsnettobetrag,SG27,MOA,,,,,,Muss, + 150,Positionsnettobetrag,SG27,MOA,5025,,203,,Positionsbetrag (ohne USt.),X, + 151,Positionsnettobetrag,SG27,MOA,5004,,,,Geldbetrag,X [930],[930] Format: max. 2 Nachkommastellen + 152,Preis,SG29,,,,,,,Muss, + 153,Preis,SG29,PRI,,,,,,Muss, + 154,Preis,SG29,PRI,5125,,CAL,,Berechnungspreis,X, + 155,Preis,SG29,PRI,5118,,,,"Preis, Betrag",X [946],[946] Format: max. 11 Nachkommastellen + 156,Umsatzsteuer der Position,SG34,,,,,,,Muss, + 157,Umsatzsteuer der Position,SG34,TAX,,,,,,Muss, + 158,Umsatzsteuer der Position,SG34,TAX,5283,,,,,7, + 159,Umsatzsteuer der Position,SG34,TAX,5153,,VAT,,Umsatzsteuer,X, + 160,Umsatzsteuer der Position,SG34,TAX,5278,,,,Zoll-/Steuer-/Gebührenrate,X [902] ∧ [930],"[902] Format: Möglicher Wert: ≥ 0 + [930] Format: max. 2 Nachkommastellen" + 161,Umsatzsteuer der Position,SG34,TAX,5305,,Steuerschuldnerschaft desLeistungsempfängers,,,SOAE, + 162,Abschnitts-Kontrollsegment,,UNS,,,,,,Muss, + 163,Abschnitts-Kontrollsegment,,UNS,0081,,und Summenteil,,,S, + 164,Rechnungsbetrag,SG50,,,,,,,Muss, + 165,Rechnungsbetrag,SG50,MOA,,,,,,Muss, + 166,Rechnungsbetrag,SG50,MOA,5025,,77,,Rechnungsbetrag,X, + 167,Rechnungsbetrag,SG50,MOA,5004,,,,Geldbetrag,X [930],[930] Format: max. 2 Nachkommastellen + 168,Fälliger Betrag,SG50,,,,,,,Muss, + 169,Fälliger Betrag,SG50,MOA,,,,,,Muss, + 170,Fälliger Betrag,SG50,MOA,5025,,9,,Fälliger Betrag (inkl. USt.),X, + 171,Fälliger Betrag,SG50,MOA,5004,,,,Geldbetrag,X [930],[930] Format: max. 2 Nachkommastellen + 172,Umsatzsteuer der Rechnung,SG52,,,,,,,Muss, + 173,Umsatzsteuer der Rechnung,SG52,TAX,,,,,,Muss, + 174,Umsatzsteuer der Rechnung,SG52,TAX,5283,,,,,7, + 175,Umsatzsteuer der Rechnung,SG52,TAX,5153,,VAT,,Umsatzsteuer,X, + 176,Umsatzsteuer der Rechnung,SG52,TAX,5278,,,,Zoll-/Steuer-/Gebührenrate,X [902] ∧ [930],"[902] Format: Möglicher Wert: ≥ 0 + [930] Format: max. 2 Nachkommastellen" + 177,Umsatzsteuer der Rechnung,SG52,TAX,5305,,Steuerschuldnerschaft des,,,SOAE, + 178,Besteuerungsgrundlage (steuersatzbezogen),SG52,MOA,,,,,,Muss, + 179,Besteuerungsgrundlage (steuersatzbezogen),SG52,MOA,5025,,125,,Besteuerungsgrundlage,X, + 180,Besteuerungsgrundlage (steuersatzbezogen),SG52,MOA,5004,,,,Geldbetrag,X [930],[930] Format: max. 2 Nachkommastellen + 181,Steuerbetrag (steuersatzbezogen),SG52,MOA,,,,,,Muss, + 182,Steuerbetrag (steuersatzbezogen),SG52,MOA,5025,,161,,Steuer-/Gebühren-/Abgabebetrag,X, + 183,Steuerbetrag (steuersatzbezogen),SG52,MOA,5004,,,,Geldbetrag,X [930],[930] Format: max. 2 Nachkommastellen + 184,Nachrichtenende,,UNT,,,,,,Muss, + 185,Nachrichtenende,,UNT,0074,,,,Anzahl der Segmente in einerNachricht,X, + 186,Nachrichtenende,,UNT,0062,,,,Nachrichten-Referenznummer,X, + + ''' +# --- +# name: TestCli.test_kohlrahbi_cli_with_valid_arguments[33004] + ''' + ,Segmentname,Segmentgruppe,Segment,Datenelement,Segment ID,Code,Qualifier,Beschreibung,Bedingungsausdruck,Bedingung + 0,Nachrichten-Kopfsegment,,UNH,,,,,,Muss, + 1,Nachrichten-Kopfsegment,,UNH,0062,,,,Nachrichten-Referenznummer,X, + 2,Nachrichten-Kopfsegment,,UNH,0065,,REMADV,,Zahlungsavis,X, + 3,Nachrichten-Kopfsegment,,UNH,0052,,D,,Entwurfs-Version,X, + 4,Nachrichten-Kopfsegment,,UNH,0054,,05A,,Ausgabe 2005 - A,X, + 5,Nachrichten-Kopfsegment,,UNH,0051,,UN,,UN/CEFACT,X, + 6,Nachrichten-Kopfsegment,,UNH,0057,,2.9c,,Versionsnummer derzugrundeliegendenBDEW-Nachrichtenbeschreibung,X, + 7,Beginn der Nachricht,,BGM,,,,,,Muss, + 8,Beginn der Nachricht,,BGM,1001,,239,,Abgelehnte Forderung(Nicht-Zahlungsavis),X, + 9,Beginn der Nachricht,,BGM,1004,,,,Dokumentennummer,X, + 10,Dokumentendatum,,DTM,,,,,,Muss, + 11,Dokumentendatum,,DTM,2005,,137,,Dokumenten-/Nachrichtendatum/-zeit,X, + 12,Dokumentendatum,,DTM,2380,,,,"Datum oder Uhrzeit oderZeitspanne, Wert",X [931],[931] Format: ZZZ = +00 + 13,Dokumentendatum,,DTM,2379,,303,,CCYYMMDDHHMMZZZ,X, + 14,Prüfidentifikator,,RFF,,,,,,Muss, + 15,Prüfidentifikator,,RFF,1153,,Z13,,Prüfidentifikator,X, + 16,Prüfidentifikator,,RFF,1154,,33003,,Abweisung Kopf undSumme,, + 17,Prüfidentifikator,,RFF,1154,,33004,,Abweisung Position,X, + 18,MP-ID Absender,SG1,,,,,,,Muss, + 19,MP-ID Absender,SG1,NAD,,,,,,Muss, + 20,MP-ID Absender,SG1,NAD,3035,,MS,,Dokumenten-/Nachrichtenausstellerbzw. -absender,X, + 21,MP-ID Absender,SG1,NAD,3039,,,,MP-ID,X [45],[45] Nur MP-ID aus Sparte Strom + 22,MP-ID Absender,SG1,NAD,3055,,9,,GS1,X, + 23,MP-ID Absender,SG1,NAD,3055,,293,,"DE, BDEW(Bundesverband derEnergie- undWasserwirtschaft e.V.)",X, + 24,Ansprechpartner,SG3,,,,,,,Kann [503],"[503] Hinweis: Empfohlen, um bei Abweisung Ansprechpartner für Rückfragen zu erreichen." + 25,Ansprechpartner,SG3,CTA,,,,,,Muss, + 26,Ansprechpartner,SG3,CTA,3139,,IC,,Informationsstelle,X, + 27,Ansprechpartner,SG3,CTA,3412,,,,Abteilung oder Bearbeiter,X, + 28,Kommunikationsverbindung,SG3,COM,,,,,,Muss, + 29,Kommunikationsverbindung,SG3,COM,3148,,,,"Kommunikationsadresse,Identifikation",X (([939][89]) ∨([940][90])) ∧[549],"[89] wenn im DE3155 in demselben COM der Code EM vorhanden ist + [90] wenn im DE3155 in demselben COM der Code TE / FX / AJ / AL vorhanden ist + [549] Hinweis: Es darf nur eine Information im DE3148 übermittelt werden + [939] Format: Die Zeichenkette muss die Zeichen @ und . enthalten + [940] Format: Die Zeichenkette muss mit dem Zeichen + beginnen und danach dürfen nur noch Ziffern folgen" + 30,Kommunikationsverbindung,SG3,COM,3155,,EM,,E-Mail,X [1P0..1], + 31,Kommunikationsverbindung,SG3,COM,3155,,FX,,Telefax,X [1P0..1], + 32,Kommunikationsverbindung,SG3,COM,3155,,TE,,Telefon,X [1P0..1], + 33,Kommunikationsverbindung,SG3,COM,3155,,AJ,,weiteres Telefon,X [1P0..1], + 34,Kommunikationsverbindung,SG3,COM,3155,,AL,,Handy,X [1P0..1], + 35,MP-ID Empfänger,SG1,,,,,,,Muss, + 36,MP-ID Empfänger,SG1,NAD,,,,,,Muss, + 37,MP-ID Empfänger,SG1,NAD,3035,,MR,,Nachrichtenempfänger,X, + 38,MP-ID Empfänger,SG1,NAD,3039,,,,MP-ID,X [45],[45] Nur MP-ID aus Sparte Strom + 39,MP-ID Empfänger,SG1,NAD,3055,,9,,GS1,X, + 40,MP-ID Empfänger,SG1,NAD,3055,,293,,"DE, BDEW(Bundesverband derEnergie- undWasserwirtschaft e.V.)",X, + 41,Währungsangaben,SG4,,,,,,,Muss, + 42,Währungsangaben,SG4,CUX,,,,,,Muss, + 43,Währungsangaben,SG4,CUX,6347,,2,,Referenzwährung,X, + 44,Währungsangaben,SG4,CUX,6345,,EUR,,Euro,X, + 45,Währungsangaben,SG4,CUX,6343,,11,,Zahlungswährung,X, + 46,Dokument-/Nachrichten- Einzelheiten,SG5,,,,,,,Muss, + 47,Dokument-/Nachrichten- Einzelheiten,SG5,DOC,,,,,,Muss, + 48,Dokument-/Nachrichten- Einzelheiten,SG5,DOC,1001,,380,,Handelsrechnung,X, + 49,Dokument-/Nachrichten- Einzelheiten,SG5,DOC,1004,,,,Dokumentennummer,X [511],[511] Hinweis: BGM DE1004 aus der abgelehnten INVOIC- Nachricht + 50,Geforderter Rechnungsbetrag,SG5,MOA,,,,,,Muss, + 51,Geforderter Rechnungsbetrag,SG5,MOA,5025,,9,,Fälliger Betrag (inkl. USt.),X, + 52,Geforderter Rechnungsbetrag,SG5,MOA,5004,,,,Geldbetrag,X [930] [501],"[501] Hinweis: An dieser Stelle ist der Betrag aus SG50 MOA+9 der zugrundeliegenden INVOIC zu übernehmen. + [930] Format: max. 2 Nachkommastellen" + 53,Überweisungsbetrag,SG5,MOA,,,,,,Muss, + 54,Überweisungsbetrag,SG5,MOA,5025,,12,,Überweisungsbetrag,X, + 55,Überweisungsbetrag,SG5,MOA,5004,,,,Geldbetrag,X [926],[926] Format: Möglicher Wert: 0 + 56,Rechnungsdatum,SG5,DTM,,,,,,Muss, + 57,Rechnungsdatum,SG5,DTM,2005,,137,,Dokumenten-/Nachrichtendatum/-zeit,X, + 58,Rechnungsdatum,SG5,DTM,2380,,,,"Datum oder Uhrzeit oderZeitspanne, Wert",X [931],[931] Format: ZZZ = +00 + 59,Rechnungsdatum,SG5,DTM,2379,,303,,CCYYMMDDHHMMZZZ,X, + 60,Referenz auf COMDIS,SG5,RFF,,,,,,Muss [98] ⊻ [99],"[42] Wenn in SG7 AJT DE1082 = E_0407/E_0568/E_0521/ E_0517/E_0266 + [98] Wenn in SG12 AJT DE1082 = E_0407 + [99] Wenn in SG12 AJT DE1082 = E_0568" + 61,Referenz auf COMDIS,SG5,RFF,1153,,ACW,,Referenznummer einervorangegangenenNachricht,X, + 62,Referenz auf COMDIS,SG5,RFF,1154,,,,"Referenz, Identifikation",X [512],[512] Hinweis: BGM DE1004 aus der abgelehnten COMDIS-Nachricht + 63,Abweichungsgrund,SG7,,,,,,,,"[517] Hinweis: Wenn in dieser SG5 in AJT DE4465 ein Code aus Cluster Ablehnung auf Summenebene verwendet wird, ist diese SG7 so oft zu wiederholen, bis alle Fehler der Summenebene genannt sind. + [518] Hinweis: Wenn in dieser SG5 in AJT DE4465 ein Code aus Cluster Ablehnung auf Kopfebene verwendet wird, der von A80 abweicht, ist diese SG7 genau einmal zu nutzen. + [519] Hinweis: Diese SG7 ist so oft mit AJT DE4465 = A74 zu wiederholen, bis alle Rechnungsnummern im RFF- Segment dieser SG7 genannt sind, die in der INVOIC fehlen, die in diesem SG5 DOC DE1004 genannt ist + [520] Hinweis: Diese SG7 ist so oft mit AJT DE4465 = A75 zu wiederholen, bis alle Rechnungsnummern der Rechnungen genannt sind, die mindestens eine Abschlagsrechnung enthalten, die in der INVOIC abgerechnet wurden, die in diesem SG5 DOC DE1004 genannt ist. + [521] Hinweis: Diese SG7 ist so oft mit AJT DE4465 = A76 zu wiederholen, bis alle Rechnungsnummern der Abschlagsrechnungen genannt sind, die in der INVOIC, die in diesem SG5 DOC DE1004 genannt ist, nicht hätten berücksichtigt werden dürfen. + [535] Hinweis: Diese SG7 ist so oft mit AJT DE4465 = A80 zu wiederholen, bis die Rechnungsnummern der nicht stornierten Sonderrechnungen mit derselben Sonderrechnungsart wie sie in Sonderrechnung genannt ist die in diesem SG5 DOC" + 64,Abweichungsgrund,SG7,AJT,,,,,,, + 65,Abweichungsgrund,SG7,AJT,4465,,,,Code des Prüfschritts,,"[11] Wenn in diesem AJT DE1082 = E_0406 + [12] Wenn in diesem AJT DE1082 = E_0407 + [14] A-Code aus Cluster Ablehnung auf Kopfebene + [16] A-Code aus Cluster Ablehnung auf Summenebene + [47] Wenn in diesem AJT DE1082 = E_0210 + [48] Wenn in diesem AJT DE1082 = E_0259 + [75] Wenn in diesem AJT DE1082 = E_0264 + [76] Wenn in diesem AJT DE1082 = E_0266 + [77] Wenn in diesem AJT DE1082 = E_0515 + [78] Wenn in diesem AJT DE1082 = E_0517 + [79] Wenn in diesem AJT DE1082 = E_0519 + [80] Wenn in diesem AJT DE1082 = E_0521 + [91] Wenn in dieser SG7 AJT DE1082 = E_0566 + [92] Wenn in dieser SG7 AJT DE1082 = E_0568" + 66,Abweichungsgrund,SG7,AJT,1082,,E_0210,,EBD Nr. E_0210,, + 67,Abweichungsgrund,SG7,AJT,1082,,E_0259,,EBD Nr. E_0259,, + 68,Abweichungsgrund,SG7,AJT,1082,,E_0264,,EBD Nr. E_0264,, + 69,Abweichungsgrund,SG7,AJT,1082,,E_0266,,EBD Nr. E_0266,, + 70,Abweichungsgrund,SG7,AJT,1082,,E_0406,,EBD Nr. E_0406,, + 71,Abweichungsgrund,SG7,AJT,1082,,E_0407,,EBD Nr. E_0407,, + 72,Abweichungsgrund,SG7,AJT,1082,,E_0515,,EBD Nr. E_0515,, + 73,Abweichungsgrund,SG7,AJT,1082,,E_0517,,EBD Nr. E_0517,, + 74,Abweichungsgrund,SG7,AJT,1082,,E_0519,,EBD Nr. E_0519,, + 75,Abweichungsgrund,SG7,AJT,1082,,E_0521,,EBD Nr. E_0521,, + 76,Zugehörige Rechnung,SG7,RFF,,,,,,,"[11] Wenn in diesem AJT DE1082 = E_0406 + [12] Wenn in diesem AJT DE1082 = E_0407 + [36] Wenn in dieser SG7 AJT DE4465 = A12/A75/A80/AE1" + 77,Zugehörige Rechnung,SG7,RFF,1153,,AFL,,Zugehörige Rechnungen,, + 78,Zugehörige Rechnung,SG7,RFF,1154,,,,"Referenz, Identifikation",,[536] Hinweis: Dieses DE darf keine Abschlagsrechnungsnummer enthalten + 79,Nähere Erläuterung des Abweichungsgrundes,SG7,FTX,,,,,,,"[22] Wenn in dieser SG7 AJT DE4465 = A02/A06/A16/ A66/A67/A68/A69/A78/A90/ A95/A96/AC3/AC4 + [39] Wenn in dieser SG7 AJT DE4465 = AC1 + [40] Wenn in dieser SG7 AJT DE1082 = E_0406 + [41] Wenn in dieser SG7 AJT DE1082 = E_0407 + [49] Wenn in dieser SG7 AJT DE4465 = A05/A22/A23/ A90/A96 + [50] Wenn in dieser SG7 AJT DE4465 = A05/A18/A19/ A20/A90/A96 + [57] Wenn in dieser SG7 AJT DE1082 = E_0210 + [58] Wenn in dieser SG7 AJT DE1082 = E_0259 + [81] Wenn in dieser SG7 AJT DE1082 = E_0264 + [82] Wenn in dieser SG7 AJT DE1082 = E_0515 + [83] Wenn in dieser SG7 AJT DE1082 = E_0519 + [84] Wenn in dieser SG7 AJT DE1082 = E_0266 + [85] Wenn in dieser SG7 AJT DE1082 = E_0517 + [86] Wenn in dieser SG7 AJT DE1082 = E_0521 + [87] Wenn in dieser SG7 AJT DE4465 = A05/A21/A22/ A23/A90/A96/AE7" + 80,Nähere Erläuterung des Abweichungsgrundes,SG7,FTX,4451,,ABO,,Information überAbweichung,, + 81,Nähere Erläuterung des Abweichungsgrundes,SG7,FTX,4440,,,,Freier Text,,[548] Hinweis: Die Befüllung des Datenelements ergibt sich aus dem zugehörigen EBD. + 82,Enthaltene Abschlagsrechnungen,SG7,FTX,,,,,,,"[18] Wenn in dieser SG7 AJT DE4465 = A74/A75/A76/AC5 + [529] Hinweis: Wenn in dieser SG7 AJT DE4465 = A75 vorhanden, dann dürfen in den DE4440 dieses FTX- Segments nur Abschlagsrechnungsnummern genannt sein, welche in der Rechnung enthalten sind, deren Nummer in dieser SG7 in SG7 RFF+AFL angegeben ist." + 83,Enthaltene Abschlagsrechnungen,SG7,FTX,4451,,Z14,,Enthaltene Abschläge,, + 84,Enthaltene Abschlagsrechnungen,SG7,FTX,4440,,,,Freier Text,,"[523] Hinweis: Jede Rechnungsnummer einer Abschlagsrechnung muss in einem separaten DE4440 angegeben werden. Reichen die fünf DE4440 für die Rechnungsnummern aller anzugebenden Abschlagrechnungen nicht aus, ist das FTX+Z14 zu wiederholen." + 85,Fehlende Positionen,SG7,FTX,,,,,,,"[56] Wenn in dieser SG7 AJT DE4465 = A21 + [57] Wenn in dieser SG7 AJT DE1082 = E_0210 + [81] Wenn in dieser SG7 AJT DE1082 = E_0264 + [82] Wenn in dieser SG7 AJT DE1082 = E_0515 + [83] Wenn in dieser SG7 AJT DE1082 = E_0519 + [84] Wenn in dieser SG7 AJT DE1082 = E_0266 + [85] Wenn in dieser SG7 AJT" + 86,Fehlende Positionen,SG7,FTX,4451,,Z16,,Positionsnummern ausdem Angebot,, + 87,Fehlende Positionen,SG7,FTX,4440,,,,Freier Text,,"[538] Hinweis: Jede Positionsnummer eines Angebotes muss in einem separaten DE4440 angegeben werden. Reichen die fünf DE4440 für die Positionsnummern aller anzugebenden Angebote nicht aus, ist das SG7 FTX+Z16 zu wiederholen." + 88,Identifikation der Zeile/ Position im Dokument,SG10,,,,,,,Muss [525],"[525] Hinweis: Diese SG10 ist so oft zu wiederholen, bis alle Fehler der Positionsebene genannt sind." + 89,Identifikation der Zeile/ Position im Dokument,SG10,DLI,,,,,,Muss, + 90,Identifikation der Zeile/ Position im Dokument,SG10,DLI,1073,,1,,Enthalten inDokument/Nachricht,X, + 91,Identifikation der Zeile/ Position im Dokument,SG10,DLI,1082,,,,Positionsnummer,X [526],"[526] Hinweis: Wert aus DE1082 der SG26 in der sich der nachfolgende Fehler in der INVOIC befindet, die in diesem SG5 DOC DE1004 genannt ist." + 92,Abweichungsgrund auf Positionsebene,SG12,,,,,,,Muss [533] ⊻ [534],"[533] Hinweis: Wenn in dieser SG12 AJT DE4465 = AA1/ AA6/AA7/AB8/AD6, ist diese SG12 so oft mit AJT DE4465 = Code zu wiederholen, bis alle Rechnungsnummern im RFF- Segment dieser SG12 genannt sind. + [534] Hinweis: Wenn in dieser SG12 AJT DE4465 = A34/ A39/AA2/AB2, ist diese SG12 ist so oft mit AJT DE4465 = Code zu wiederholen, bis alle" + 93,Abweichungsgrund auf Positionsebene,SG12,AJT,,,,,,Muss, + 94,Abweichungsgrund auf Positionsebene,SG12,AJT,4465,,,,Code des Prüfschritts,X ([15] ∧ ([11] ⊻[12] ⊻ [47] ⊻ [48]⊻ [75] ⊻ [76] ⊻[77] ⊻ [78] ⊻ [79]⊻ [80] ⊻ [91] ⊻[92])) ⊻ [33] ⊻[34],"[11] Wenn in diesem AJT DE1082 = E_0406 + [12] Wenn in diesem AJT DE1082 = E_0407 + [15] A-Code aus Cluster Ablehnung auf Positionsebene + [33] Wenn in diesem AJT DE1082 = S_0103 + [34] Wenn in diesem AJT DE1082 = S_0104 + [47] Wenn in diesem AJT DE1082 = E_0210 + [48] Wenn in diesem AJT DE1082 = E_0259 + [75] Wenn in diesem AJT DE1082 = E_0264 + [76] Wenn in diesem AJT DE1082 = E_0266 + [77] Wenn in diesem AJT DE1082 = E_0515 + [78] Wenn in diesem AJT DE1082 = E_0517 + [79] Wenn in diesem AJT DE1082 = E_0519 + [80] Wenn in diesem AJT DE1082 = E_0521 + [91] Wenn in dieser SG7 AJT DE1082 = E_0566 + [92] Wenn in dieser SG7 AJT DE1082 = E_0568" + 95,Abweichungsgrund auf Positionsebene,SG12,AJT,1082,,E_0210,,EBD Nr. E_0210,X, + 96,Abweichungsgrund auf Positionsebene,SG12,AJT,1082,,E_0259,,EBD Nr. E_0259,X, + 97,Abweichungsgrund auf Positionsebene,SG12,AJT,1082,,E_0264,,EBD Nr. E_0264,X, + 98,Abweichungsgrund auf Positionsebene,SG12,AJT,1082,,E_0266,,EBD Nr. E_0266,X, + 99,Abweichungsgrund auf Positionsebene,SG12,AJT,1082,,E_0406,,EBD Nr. E_0406,X, + 100,Abweichungsgrund auf Positionsebene,SG12,AJT,1082,,E_0407,,EBD Nr. E_0407,X, + 101,Abweichungsgrund auf Positionsebene,SG12,AJT,1082,,E_0515,,EBD Nr. E_0515,X, + 102,Abweichungsgrund auf Positionsebene,SG12,AJT,1082,,E_0517,,EBD Nr. E_0517,X, + 103,Abweichungsgrund auf Positionsebene,SG12,AJT,1082,,E_0519,,EBD Nr. E_0519,X, + 104,Abweichungsgrund auf Positionsebene,SG12,AJT,1082,,E_0521,,EBD Nr. E_0521,X, + 105,Abweichungsgrund auf Positionsebene,SG12,AJT,1082,,E_0566,,EBD Nr. E_0566,X, + 106,Abweichungsgrund auf Positionsebene,SG12,AJT,1082,,E_0568S_0103S_0104,,EBD Nr. E_0568Codeliste Strom Nr.S_0103Codeliste Strom Nr.S_0104,XXX, + 107,Zugehörige Rechnung oder Bestellung auf Positionsebene,SG12,RFF,,,,,,Muss [26] ⊻ [35]⊻ ([70] ∧ ([65] ⊻[68] ⊻ [66] ⊻[69] ⊻ [64] ⊻[67])) ⊻ ([97] ∧([51] ⊻ [52])),"[26] Wenn in dieser SG12 AJT DE4465 = A51/A62/A82/ AA1/AA6/AA7/AB8/AD6 + [35] Wenn in dieser SG12 AJT DE4465 = A34/A39/AA2/AB2 + [51] Wenn in dieser SG12 AJT DE1082 = E_0406 + [52] Wenn in dieser SG12 AJT DE1082 = E_0407 + [64] Wenn in dieser SG12 AJT DE1082 = E_0264 + [65] Wenn in dieser SG12 AJT DE1082 = E_0515 + [66] Wenn in dieser SG12 AJT DE1082 = E_0519 + [67] Wenn in dieser SG12 AJT DE1082 = E_0266 + [68] Wenn in dieser SG12 AJT DE1082 = E_0517 + [69] Wenn in dieser SG12 AJT DE1082 = E_0521 + [70] Wenn in dieser SG12 AJT DE4465 = A15 + [97] Wenn in dieser SG12 AJT DE4465 = A27 " + 108,Zugehörige Rechnung oder Bestellung auf Positionsebene,SG12,RFF,1153,,AFL,,Zugehörige Rechnungen,X [26] ⊻ ([70] ∧([65] ⊻ [68] ⊻[66] ⊻ [69] ⊻[64] ⊻ [67])) ⊻([97] ∧ ([51] ⊻[52])), + 109,Zugehörige Rechnung oder Bestellung auf Positionsebene,SG12,RFF,1153,,ACW,,Referenznummer einervorangegangenenNachricht,X [35],"[26] Wenn in dieser SG12 AJT DE4465 = A51/A62/A82/ AA1/AA6/AA7/AB8/AD6 + [35] Wenn in dieser SG12 AJT DE4465 = A34/A39/AA2/AB2 + [51] Wenn in dieser SG12 AJT DE1082 = E_0406 + [52] Wenn in dieser SG12 AJT DE1082 = E_0407 + [64] Wenn in dieser SG12 AJT DE1082 = E_0264 + [65] Wenn in dieser SG12 AJT DE1082 = E_0515 + [66] Wenn in dieser SG12 AJT DE1082 = E_0519 + [67] Wenn in dieser SG12 AJT DE1082 = E_0266 + [68] Wenn in dieser SG12 AJT DE1082 = E_0517 + [69] Wenn in dieser SG12 AJT DE1082 = E_0521 + [70] Wenn in dieser SG12 AJT DE4465 = A15 + [97] Wenn in dieser SG12 AJT DE4465 = A27 " + 110,Zugehörige Rechnung oder Bestellung auf Positionsebene,SG12,RFF,1154,,,,"Referenz, Identifikation",X, + 111,Nähere Erläuterung des Abweichungsgrundes auf Positionsebene,SG12,FTX,,,,,,Muss [43] ⊻([28] ∧ ([51] ⊻[52])) ⊻ ([53] ∧([54] ⊻ [55] ⊻[91] ⊻ [92])) ⊻([71] ∧ ([64] ⊻[65] ⊻ [66] ⊻ [67]⊻ [68] ⊻ [69]))Kann,"[28] Wenn in dieser SG12 AJT DE4465 = A23/A26/A35/ A36/A38/A46/A47/A48/A50/ A58/A59/A61/A77/A84/A99 + [43] Wenn in SG12 AJT DE4465=28 + [51] Wenn in dieser SG12 AJT DE1082 = E_0406 + [52] Wenn in dieser SG12 AJT DE1082 = E_0407 + [53] Wenn in dieser SG12 AJT DE4465 = A25/A99/AF1 + [54] Wenn in dieser SG12 AJT DE1082 = E_0210 + [55] Wenn in dieser SG12 AJT DE1082 = E_0259 + [64] Wenn in dieser SG12 AJT DE1082 = E_0264 + [65] Wenn in dieser SG12 AJT DE1082 = E_0515 + [66] Wenn in dieser SG12 AJT DE1082 = E_0519 + [67] Wenn in dieser SG12 AJT DE1082 = E_0266 + [68] Wenn in dieser SG12 AJT DE1082 = E_0517 + [69] Wenn in dieser SG12 AJT DE1082 = E_0521 + [71] Wenn in dieser SG12 AJT DE4465 = A99 + [91] Wenn in dieser SG7 AJT DE1082 = E_0566 + [92] Wenn in dieser SG7 AJT DE1082 = E_0568" + 112,Nähere Erläuterung des Abweichungsgrundes auf Positionsebene,SG12,FTX,4451,,ABO,,Information überAbweichung,X, + 113,Nähere Erläuterung des Abweichungsgrundes auf Positionsebene,SG12,FTX,4440,,,,Freier Text,X [548],[548] Hinweis: Die Befüllung des Datenelements ergibt sich aus dem zugehörigen EBD. + 114,Trennung von Positions- u. Summenteil,,UNS,,,,,,Muss, + 115,Trennung von Positions- u. Summenteil,,UNS,0081,,S,,Trennung von Positions-und Summenteil,X, + 116,Summenbetrag,,MOA,,,,,,Muss, + 117,Summenbetrag,,MOA,5025,,12,,Überweisungsbetrag,X, + 118,Summenbetrag,,MOA,5004,,,,Geldbetrag,X [926],[926] Format: Möglicher Wert: 0 + 119,Nachrichten-Endesegment,,UNT,,,,,,Muss, + 120,Nachrichten-Endesegment,,UNT,0074,,,,Anzahl der Segmente in einerNachricht,X, + 121,Nachrichten-Endesegment,,UNT,0062,,,,Nachrichten-Referenznummer,X, + 122,Nachrichten-Endesegment,,POS,,,,,,,Kommentar + 123,8,,POS,,,,,,,Kommentar + 124,8,,POS,,,,,,,Kommentar + 125,41,,POS,,,,,,,Kommentar + 126,30,,POS,,,,,,,Kommentar + 127,4,,POS,,,,,,,Kommentar + 128,4,,POS,,,,,,,Kommentar + 129,1,,POS,,,,,,,Kommentar + 130,20,,POS,,,,,,,Kommentar + 131,5,,POS,,,,,,, Einheit + 132,Summe der Netzentgelte,,POS,,,,,,, Einheit + 133,Summe der Netzentgelte,,POS,,,,,,, Einheit + 134,Summe der Netzentgelte,,POS,,,,,,, Einheit + 135,Summe der Netzentgelte,,POS,,,,,,, Einheit + 136,Summe der Netzentgelte,,POS,,,,,,, Einheit + + ''' +# --- +# name: TestCli.test_kohlrahbi_cli_with_valid_arguments[35001] + ''' + ,Segmentname,Segmentgruppe,Segment,Datenelement,Segment ID,Code,Qualifier,Beschreibung,Bedingungsausdruck,Bedingung + 0,Nachrichten-Kopfsegment,,UNH,,00001,,,,Muss, + 1,Nachrichten-Kopfsegment,,UNH,0062,00001,,,Nachrichten-Referenznummer,X, + 2,Nachrichten-Kopfsegment,,UNH,0065,00001,REQOTE,,Anfrage,X, + 3,Nachrichten-Kopfsegment,,UNH,0052,00001,D,,Entwurfs-Version,X, + 4,Nachrichten-Kopfsegment,,UNH,0054,00001,10A,,Ausgabe 2010 - A,X, + 5,Nachrichten-Kopfsegment,,UNH,0051,00001,UN,,UN/CEFACT,X, + 6,Nachrichten-Kopfsegment,,UNH,0057,00001,1.3,,Versionsnummer derzugrundeliegendenBDEW-Nachrichtenbeschreibung,X, + 7,Beginn der Nachricht,,BGM,,00002,,,,Muss, + 8,Beginn der Nachricht,,BGM,1001,00002,311,,Aufforderung zurAngebotsabgabe (Anfrage),X, + 9,Beginn der Nachricht,,BGM,1004,00002,,,Dokumentennummer,X, + 10,Nachrichtendatum,,DTM,,00003,,,,Muss, + 11,Nachrichtendatum,,DTM,2005,00003,137,,Dokumenten-/Nachrichtendatum/-zeit,X, + 12,Nachrichtendatum,,DTM,2380,00003,,,"Datum oder Uhrzeit oderZeitspanne, Wert",X [931] [494],"[494] Das hier genannte Datum muss der Zeitpunkt sein, zu dem das Dokument erstellt wurde, oder ein Zeitpunkt, der davor liegt. + [931] Format: ZZZ = +00" + 13,Nachrichtendatum,,DTM,2379,00003,303,,CCYYMMDDHHMMZZZ,X, + 14,Datum zum geplanten Leistungsbeginn,,DTM,,00004,,,,Muss, + 15,Datum zum geplanten Leistungsbeginn,,DTM,2005,00004,76,,"Lieferdatum/-zeit, geplant",X, + 16,Datum zum geplanten Leistungsbeginn,,DTM,2380,00004,,,"Datum oder Uhrzeit oderZeitspanne, Wert",X [UB3], + 17,Datum zum geplanten Leistungsbeginn,,DTM,2379,00004,303,,CCYYMMDDHHMMZZZ,X, + 18,Prüfidentifikator,SG1,,,,,,,Muss, + 19,Prüfidentifikator,SG1,RFF,,00009,,,,Muss, + 20,Prüfidentifikator,SG1,RFF,1153,00009,Z13,,Prüfidentifikator,X, + 21,Prüfidentifikator,SG1,RFF,1154,00009,35001,,Anforderung AngebotGeräteübernahme,X, + 22,MP-ID Absender,SG11,,,,,,,Muss, + 23,MP-ID Absender,SG11,NAD,,00014,,,,Muss, + 24,MP-ID Absender,SG11,NAD,3035,00014,Nachrichtenaussteller bzw.-absender,,,MS, + 25,MP-ID Absender,SG11,NAD,3039,00014,,,MP-ID,X, + 26,MP-ID Absender,SG11,NAD,3055,00014,9,,GS1,X, + 27,MP-ID Absender,SG11,NAD,3055,,293,,"DE, BDEW (Bundesverbandder Energie- undWasserwirtschaft e.V.)",X, + 28,MP-ID Absender,SG11,NAD,3055,,332,,"DE, DVGW Service &",X, + 29,Ansprechpartner,SG14,,,,,,,Muss, + 30,Ansprechpartner,SG14,CTA,,00015,,,,Muss, + 31,Ansprechpartner,SG14,CTA,3139,00015,,,,IC, + 32,Ansprechpartner,SG14,CTA,3412,00015,,,Kontakt,X [500],[500] Hinweis: Angabe eines technischen Ansprechpartners für die Geräteübernahme + 33,Kommunikationsverbindung,SG14,COM,,00016,,,,Muss, + 34,Kommunikationsverbindung,SG14,COM,3148,00016,,,"Kommunikationsadresse,Identifikation",X, + 35,Kommunikationsverbindung,SG14,COM,3155,00016,EM,,Elektronische Post,X [1P0..1], + 36,Kommunikationsverbindung,SG14,COM,3155,,FX,,Telefax,X [1P0..1], + 37,Kommunikationsverbindung,SG14,COM,3155,,TE,,Telefon,X [1P0..1], + 38,Kommunikationsverbindung,SG14,COM,3155,,AJ,,weiteres Telefon,X [1P0..1], + 39,Kommunikationsverbindung,SG14,COM,3155,,AL,,Handy,X [1P0..1], + 40,MP-ID Empfänger,SG11,,,,,,,Muss, + 41,MP-ID Empfänger,SG11,NAD,,00017,,,,Muss, + 42,MP-ID Empfänger,SG11,NAD,3035,00017,,,,MR, + 43,MP-ID Empfänger,SG11,NAD,3039,00017,,,MP-ID,X, + 44,MP-ID Empfänger,SG11,NAD,3055,00017,9,,GS1,X, + 45,MP-ID Empfänger,SG11,NAD,3055,,293,,"DE, BDEW (Bundesverbandder Energie- undWasserwirtschaft e.V.)",X, + 46,MP-ID Empfänger,SG11,NAD,3055,,332,,"DE, DVGW Service &Consult GmbH",X, + 47,"Liefer-, bzw. Bezugsort",SG11,,,,,,,Muss, + 48,"Liefer-, bzw. Bezugsort",SG11,NAD,,00018,,,,Muss, + 49,"Liefer-, bzw. Bezugsort",SG11,NAD,3035,00018,,,,DP, + 50,Meldepunkt,SG11,LOC,,00019,,,,Muss, + 51,Meldepunkt,SG11,LOC,3227,00019,,,,172, + 52,Meldepunkt,SG11,LOC,3225,00019,,,Identifikator,X [951] [503],"[503] Hinweis: Verwendung der ID der Messlokation + [951] Format: Zählpunktbezeichnung" + 53,Positionsdaten,SG27,,,,,,,Muss [2005],[2005] Pro Nachricht ist die SG27 genau einmal anzugeben + 54,Positionsdaten,SG27,LIN,,00020,,,,Muss, + 55,Positionsdaten,SG27,LIN,1082,00020,,,Positionsnummer,X [903],[903] Format: Möglicher Wert: 1 + 56,Abschnitts-Kontrollsegment,,UNS,,00049,,,,Muss, + 57,Abschnitts-Kontrollsegment,,UNS,0081,00049,und Summenteil,,,S, + 58,Nachrichten-Endesegment,,UNT,,00050,,,,Muss, + 59,Nachrichten-Endesegment,,UNT,0074,00050,,,Anzahl der Segmente in einerNachricht,X, + 60,Nachrichten-Endesegment,,UNT,0062,00050,,,Nachrichten-Referenznummer,X, + + ''' +# --- +# name: TestCli.test_kohlrahbi_cli_with_valid_arguments[35004] + ''' + ,Segmentname,Segmentgruppe,Segment,Datenelement,Segment ID,Code,Qualifier,Beschreibung,Bedingungsausdruck,Bedingung + 0,Nachrichten-Kopfsegment,,UNH,,00001,,,,Muss, + 1,Nachrichten-Kopfsegment,,UNH,0062,00001,,,Nachrichten-Referenznummer,X, + 2,Nachrichten-Kopfsegment,,UNH,0065,00001,REQOTE,,Anfrage,X, + 3,Nachrichten-Kopfsegment,,UNH,0052,00001,D,,Entwurfs-Version,X, + 4,Nachrichten-Kopfsegment,,UNH,0054,00001,10A,,Ausgabe 2010 - A,X, + 5,Nachrichten-Kopfsegment,,UNH,0051,00001,UN,,UN/CEFACT,X, + 6,Nachrichten-Kopfsegment,,UNH,0057,00001,1.3,,Versionsnummer derzugrundeliegendenBDEW-Nachrichtenbeschreibung,X, + 7,Beginn der Nachricht,,BGM,,00002,,,,Muss, + 8,Beginn der Nachricht,,BGM,1001,00002,Z74,,Bestellung eines Angebotseiner Konfiguration,X [36], + 9,Beginn der Nachricht,,BGM,1001,,Z82,,Bestellung eines Angebotseiner Konfiguration durchden LF,X [35],"[35] Wenn MP-ID in SG11 NAD+MS mit Rolle LF vorhanden + [36] Wenn MP-ID in SG11 NAD+MS mit Rolle NB vorhanden" + 10,Beginn der Nachricht,,BGM,1004,00002,,,Dokumentennummer,X, + 11,Nachrichtendatum,,DTM,,00003,,,,Muss, + 12,Nachrichtendatum,,DTM,2005,00003,137,,Dokumenten-/Nachrichtendatum/-zeit,X, + 13,Nachrichtendatum,,DTM,2380,00003,,,"Datum oder Uhrzeit oderZeitspanne, Wert",X [931] [494],"[494] Das hier genannte Datum muss der Zeitpunkt sein, zu dem das Dokument erstellt wurde, oder ein Zeitpunkt, der davor liegt. + [931] Format: ZZZ = +00" + 14,Nachrichtendatum,,DTM,2379,00003,303,,CCYYMMDDHHMMZZZ,X, + 15,Datum zum geplanten Leistungsbeginn,,DTM,,00004,,,,Muss [16],[16] Wenn SG1 RFF+Z41 (Referenznummer des Vorgangs der Anmeldung nach WiM) nicht vorhanden + 16,Datum zum geplanten Leistungsbeginn,,DTM,2005,00004,76,,"Lieferdatum/-zeit, geplant",X, + 17,Datum zum geplanten Leistungsbeginn,,DTM,2380,00004,,,"Datum oder Uhrzeit oderZeitspanne, Wert",X [UB1], + 18,Datum zum geplanten Leistungsbeginn,,DTM,2379,00004,303,,CCYYMMDDHHMMZZZ,X, + 19,Grund des Angebots,,IMD,,00007,,,,Muss, + 20,Grund des Angebots,,IMD,7081,00007,Z55,,Änderung Konfiguration,X, + 21,Grund des Angebots,,IMD,7081,,Z64,,Neukonfiguration,X, + 22,Prüfidentifikator,SG1,,,,,,,Muss, + 23,Prüfidentifikator,SG1,RFF,,00009,,,,Muss, + 24,Prüfidentifikator,SG1,RFF,1153,00009,Z13,,Prüfidentifikator,X, + 25,Prüfidentifikator,SG1,RFF,1154,00009,35004,,Anfrage einer Konfiguration,X, + 26,Referenznummer des Vorgangs der Anmeldung nach WiM,SG1,,,,,,,Muss [15],[15] Wenn DTM+76 (Datum zum geplanten Leistungsbeginn) nicht vorhanden + 27,Referenznummer des Vorgangs der Anmeldung nach WiM,SG1,RFF,,00010,,,,Muss, + 28,Referenznummer des Vorgangs der Anmeldung nach WiM,SG1,RFF,1153,00010,Z41,,Referenznummer desVorgangs der Anmeldungnach WiM,X, + 29,Referenznummer des Vorgangs der Anmeldung nach WiM,SG1,RFF,1154,00010,,,"Referenz, Identifikation",X [507],[507] Hinweis: Vorgangsnummer aus SG4 IDE+24 DE7402 der UTILMD mit BGM+E01 mit der die Anmeldung des MSB-Wechsels erfolgt ist. + 30,Referenznummer der Nachricht der betroffenen Antwort auf Bestellung ,SG1,,,,,,,Muss [18],[18] Wenn IMD++Z55 (Änderung Konfiguration) vorhanden + 31,Referenznummer der Nachricht der betroffenen Antwort auf Bestellung ,SG1,RFF,,00011,,,,Muss, + 32,Referenznummer der Nachricht der betroffenen Antwort auf Bestellung ,SG1,RFF,1153,00011,Z42,,Referenznummer derNachricht der betroffenenAntwort auf Bestellung(Bestellbestätigung),X, + 33,Referenznummer der Nachricht der betroffenen Antwort auf Bestellung ,SG1,RFF,1154,00011,,,"Referenz, Identifikation",X [508],[508] Hinweis: Wert aus BGM+Z73 DE1004 der IFTSTA mit der die Antwort auf die Bestellung der Konfiguration übermittelt wurde + 34,Referenznummer des Vorgangs der betroffenen Antwort auf Bestellung,SG1,,,,,,,Muss [18],[18] Wenn IMD++Z55 (Änderung Konfiguration) vorhanden + 35,Referenznummer des Vorgangs der betroffenen Antwort auf Bestellung,SG1,RFF,,00012,,,,Muss, + 36,Referenznummer des Vorgangs der betroffenen Antwort auf Bestellung,SG1,RFF,1153,00012,Z43,,Referenznummer desVorgangs der betroffenenAntwort auf Bestellung(Bestellbestätigung),X, + 37,Referenznummer des Vorgangs der betroffenen Antwort auf Bestellung,SG1,RFF,1154,00012,,,"Referenz, Identifikation",X [509],[509] Hinweis: Vorgangsnummer aus CNI DE1490 der IFTSTA mit BGM+Z73 mit der die Antwort auf die Bestellung der Konfiguration übermittelt wurde + 38,MP-ID des NB des Vorgangs der Anmeldung nach WiM,SG11,,,,,,,Muss [17],[17] Wenn SG1 RFF+Z41 (Referenznummer des Vorgangs der Anmeldung nach WiM) vorhanden + 39,MP-ID des NB des Vorgangs der Anmeldung nach WiM,SG11,NAD,,00013,,,,Muss, + 40,MP-ID des NB des Vorgangs der Anmeldung nach WiM,SG11,NAD,3035,00013,,,,DDM, + 41,MP-ID des NB des Vorgangs der Anmeldung nach WiM,SG11,NAD,3039,00013,,,"Beteiligter, Identifikation",X [10],[10] MP-ID nur aus Sparte Strom + 42,MP-ID des NB des Vorgangs der Anmeldung nach WiM,SG11,NAD,3055,00013,9,,GS1,X, + 43,MP-ID des NB des Vorgangs der Anmeldung nach WiM,SG11,NAD,3055,,293,,"DE, BDEW (Bundesverbandder Energie- undWasserwirtschaft e.V.)",X, + 44,MP-ID Absender,SG11,,,,,,,Muss, + 45,MP-ID Absender,SG11,NAD,,00014,,,,Muss, + 46,MP-ID Absender,SG11,NAD,3035,00014,Nachrichtenaussteller bzw.-absender,,,MS, + 47,MP-ID Absender,SG11,NAD,3039,00014,,,MP-ID,X [10],[10] MP-ID nur aus Sparte Strom + 48,MP-ID Absender,SG11,NAD,3055,00014,9,,GS1,X, + 49,MP-ID Absender,SG11,NAD,3055,,293,,"DE, BDEW (Bundesverbandder Energie- undWasserwirtschaft e.V.)",X, + 50,Ansprechpartner,SG14,,,,,,,Muss, + 51,Ansprechpartner,SG14,CTA,,00015,,,,Muss, + 52,Ansprechpartner,SG14,CTA,3139,00015,,,,IC, + 53,Ansprechpartner,SG14,CTA,3412,00015,,,Kontakt,X, + 54,Kommunikationsverbindung,SG14,COM,,00016,,,,Muss, + 55,Kommunikationsverbindung,SG14,COM,3148,00016,,,"Kommunikationsadresse,Identifikation",X, + 56,Kommunikationsverbindung,SG14,COM,3155,00016,EM,,Elektronische Post,X [1P0..1], + 57,Kommunikationsverbindung,SG14,COM,3155,,FX,,Telefax,X [1P0..1], + 58,Kommunikationsverbindung,SG14,COM,3155,,TE,,Telefon,X [1P0..1], + 59,Kommunikationsverbindung,SG14,COM,3155,,AJ,,weiteres Telefon,X [1P0..1], + 60,Kommunikationsverbindung,SG14,COM,3155,,AL,,Handy,X [1P0..1], + 61,MP-ID Empfänger,SG11,,,,,,,Muss, + 62,MP-ID Empfänger,SG11,NAD,,00017,,,,Muss, + 63,MP-ID Empfänger,SG11,NAD,3035,00017,,,,MR, + 64,MP-ID Empfänger,SG11,NAD,3039,00017,,,MP-ID,X [10],[10] MP-ID nur aus Sparte Strom + 65,MP-ID Empfänger,SG11,NAD,3055,00017,9,,GS1,X, + 66,MP-ID Empfänger,SG11,NAD,3055,,293,,"DE, BDEW (Bundesverbandder Energie- undWasserwirtschaft e.V.)",X, + 67,"Liefer-, bzw. Bezugsort",SG11,,,,,,,Muss, + 68,"Liefer-, bzw. Bezugsort",SG11,NAD,,00018,,,,Muss, + 69,"Liefer-, bzw. Bezugsort",SG11,NAD,3035,00018,,,,DP, + 70,Meldepunkt,SG11,LOC,,00019,,,,Muss, + 71,Meldepunkt,SG11,LOC,3227,00019,,,,172, + 72,Meldepunkt,SG11,LOC,3225,00019,,,Identifikator,X ([950] [502] ∧ ([20] ∨[22])) ⊻ ([951] [503] ∧([22] ∨ [23])) ⊻ ([960][510] ∧ ([20] ∨ [21] ∨[22])) ⊻ ([961] [511] ∧([19] ∨ [20] ∨ [21])),"[19] Wenn SG27 LIN++Z64 (Erforderliches Produkt Schaltzeitdefinitionen) vorhanden + [20] Wenn SG27 LIN++Z65 (Erforderliches Produkt Leistungskurvendefinitionen) vorhanden + [21] Wenn SG27 LIN++Z66 (Erforderliches Produkt Ad-hoc- Steuerkanal) vorhanden" + 73,Erforderliches Produkt Schaltzeitdefinitionen,SG27,,,,,,,Soll [24] ∧ [2060] ∧ [28],"[24] Wenn Produkt bestellt werden soll + [28] Wenn in LOC+172 DE3225 (Meldepunkt) die ID einer Steuerbaren Ressource angegeben ist. + [2060] Pro Nachricht ist die SG27 LIN+Z64 (Erforderliches Produkt Schaltzeitdefinitionen) maximal einmal anzugeben" + 74,Erforderliches Produkt Schaltzeitdefinitionen,SG27,LIN,,00029,,,,Muss, + 75,Erforderliches Produkt Schaltzeitdefinitionen,SG27,LIN,1082,00029,,,Positionsnummer,X [903],[903] Format: Möglicher Wert: 1 + 76,Erforderliches Produkt Schaltzeitdefinitionen,SG27,LIN,1229,00029,Schaltzeitdefinitionen,,,Z64, + 77,Erforderliches Produkt Schaltzeitdefinitionen,SG27,PIA,,00030,,,,Muss, + 78,Erforderliches Produkt Schaltzeitdefinitionen,SG27,PIA,4347,00030,,,,5, + 79,Erforderliches Produkt Schaltzeitdefinitionen,SG27,PIA,7140,00030,,,Produkt-Code,X [29],"[29] Es sind nur die Konfigurations-Produkte erlaubt, die in der Codeliste der Konfigurationen im Kapitel 4.1 „Konfigurationsprodukte Schaltzeitdefinition“ enthalten sind." + 80,Erforderliches Produkt Schaltzeitdefinitionen,SG27,PIA,7143,00030,Z12,,Konfigurationsprodukt,X, + 81,Zugeordnete Schaltzeitdefinition,SG28,,,,,,,Muss, + 82,Zugeordnete Schaltzeitdefinition,SG28,CCI,,00031,,,,Muss, + 83,Zugeordnete Schaltzeitdefinition,SG28,CCI,7059,00031,,,,Z52, + 84,Zugeordnete Schaltzeitdefinition,SG28,CCI,7037,00031,,,"Merkmal, Code",X, + 85,Erforderliches Produkt Leistungskurvendefinitione n,SG27,,,,,,,Soll [24] ∧ [2061] ∧ ([25]⊻ [27] ⊻ [28]) ,"[24] Wenn Produkt bestellt werden soll + [25] Wenn in LOC+172 DE3225 (Meldepunkt) die ID einer Marktlokation angegeben ist. + [27] Wenn in LOC+172 DE3225 (Meldepunkt) die ID einer Netzlokation angegeben ist. + [28] Wenn in LOC+172 DE3225 (Meldepunkt) die ID einer Steuerbaren Ressource angegeben ist. + [2061] Pro Nachricht ist die SG27 LIN++Z65 (Erforderliches Produkt Leistungskurvendefinitionen) maximal einmal anzugeben" + 86,Erforderliches Produkt Leistungskurvendefinitione n,SG27,LIN,,00032,,,,Muss, + 87,Erforderliches Produkt Leistungskurvendefinitione n,SG27,LIN,1082,00032,,,Positionsnummer,X [903],[903] Format: Möglicher Wert: 1 + 88,Erforderliches Produkt Leistungskurvendefinitione n,SG27,LIN,1229,00032,Leistungskurvendefinitionen,,,Z65, + 89,Erforderliches Produkt Leistungskurvendefinitione n,SG27,PIA,,00033,,,,Muss, + 90,Erforderliches Produkt Leistungskurvendefinitione n,SG27,PIA,4347,00033,,,,5, + 91,Erforderliches Produkt Leistungskurvendefinitione n,SG27,PIA,7140,00033,,,Produkt-Code,X [30],"[30] Es sind nur die Konfigurations-Produkte erlaubt, die in der Codeliste der Konfigurationen im Kapitel 4.2 „Konfigurationsprodukte Leistungskurvendefinition“ enthalten sind." + 92,Erforderliches Produkt Leistungskurvendefinitione n,SG27,PIA,7143,00033,Z12,,Konfigurationsprodukt,X, + 93,Zugeordnete Leistungskurvendefinitione n,SG28,,,,,,,Muss, + 94,Zugeordnete Leistungskurvendefinitione n,SG28,CCI,,00034,,,,Muss, + 95,Zugeordnete Leistungskurvendefinitione n,SG28,CCI,7059,00034,Leistungskurvendefinition,,,Z53, + 96,Zugeordnete Leistungskurvendefinitione n,SG28,CCI,7037,00034,,,"Merkmal, Code",X, + 97,Erforderliches Produkt Ad- hoc-Steuerkanal,SG27,,,,,,,Soll [24] ∧ [2062] ∧ ([27]⊻ [28]),"[24] Wenn Produkt bestellt werden soll + [27] Wenn in LOC+172 DE3225 (Meldepunkt) die ID einer Netzlokation angegeben ist." + 98,Erforderliches Produkt Ad- hoc-Steuerkanal,SG27,LIN,,00035,,,,Muss, + 99,Erforderliches Produkt Ad- hoc-Steuerkanal,SG27,LIN,1082,00035,,,Positionsnummer,X [903],[903] Format: Möglicher Wert: 1 + 100,Erforderliches Produkt Ad- hoc-Steuerkanal,SG27,LIN,1229,00035,Ad-hoc-Steuerkanal,,,Z66, + 101,Erforderliches Produkt Ad- hoc-Steuerkanal,SG27,PIA,,00036,,,,Muss, + 102,Erforderliches Produkt Ad- hoc-Steuerkanal,SG27,PIA,4347,00036,,,,5, + 103,Erforderliches Produkt Ad- hoc-Steuerkanal,SG27,PIA,7140,00036,,,Produkt-Code,X [31],"[31] Es sind nur die Konfigurations-Produkte erlaubt, die in der Codeliste der Konfigurationen im Kapitel 4.3 „Konfigurationsprodukte Ad- Hoc-Steuerkanal“ enthalten sind." + 104,Erforderliches Produkt Ad- hoc-Steuerkanal,SG27,PIA,7143,00036,Z12,,Konfigurationsprodukt,X, + 105,Zieladresse URI,SG27,FTX,,00037,,,,Muss [513],[513] Hinweis: Für den Empfang der Mitteilung zum weiteren Vorgehen eines Steuerbefehls und der Antwort auf die Anweisung eines Steuerbefehls. + 106,Zieladresse URI,SG27,FTX,4451,00037,,,,Z17, + 107,Zieladresse URI,SG27,FTX,4440,00037,,,Zieladresse URI für KommunikationSteuerbefehl,X, + 108,Zertifikatsaussteller (Issuer),SG27,FTX,,00038,,,,Muss [513],[513] Hinweis: Für den Empfang der Mitteilung zum weiteren Vorgehen eines Steuerbefehls und der Antwort auf die Anweisung eines Steuerbefehls. + 109,Zertifikatsaussteller (Issuer),SG27,FTX,4451,00038,,,,Z24, + 110,Zertifikatsaussteller (Issuer),SG27,FTX,4440,00038,,,Zertifikatsaussteller,X [967],"[967] Format: Zertifikatskörper gemäß X509.1, BSI TR-03109-4" + 111,Zertifikatsnutzer (Subject),SG27,FTX,,00039,,,,Muss [513],[513] Hinweis: Für den Empfang der Mitteilung zum weiteren Vorgehen eines Steuerbefehls und der Antwort auf die Anweisung eines Steuerbefehls. + 112,Zertifikatsnutzer (Subject),SG27,FTX,4451,00039,,,,Z23, + 113,Zertifikatsnutzer (Subject),SG27,FTX,4440,00039,,,Zertifikatsnutzer,X [967],"[967] Format: Zertifikatskörper gemäß X509.1, BSI TR-03109-4" + 114,Erforderliches Messprodukt für Werte nach Typ 2 aus Backend,SG27,,,,,,,Soll [24] ∧ [2063] ∧ ([25]⊻ [26] ⊻ [27]),"[24] Wenn Produkt bestellt werden soll + [25] Wenn in LOC+172 DE3225 (Meldepunkt) die ID einer Marktlokation angegeben ist. + [26] Wenn in LOC+172 DE3225 (Meldepunkt) die ID einer Messlokation angegeben ist. + [27] Wenn in LOC+172 DE3225 (Meldepunkt) die ID einer Netzlokation angegeben ist. + [2063] Pro Nachricht ist die SG27 LIN++Z67 (Erforderliches Messprodukt für Werte nach Typ 2 aus Backend) maximal einmal anzugeben" + 115,Erforderliches Messprodukt für Werte nach Typ 2 aus Backend,SG27,LIN,,00040,,,,Muss, + 116,Erforderliches Messprodukt für Werte nach Typ 2 aus Backend,SG27,LIN,1082,00040,,,Positionsnummer,X [903],[903] Format: Möglicher Wert: 1 + 117,Erforderliches Messprodukt für Werte nach Typ 2 aus Backend,SG27,LIN,1229,00040,für Werte nach Typ 2 ausBackend,,,Z67, + 118,Erforderliches Messprodukt für Werte nach Typ 2 aus Backend,SG27,PIA,,00041,,,,Muss, + 119,Erforderliches Messprodukt für Werte nach Typ 2 aus Backend,SG27,PIA,4347,00041,,,,5, + 120,Erforderliches Messprodukt für Werte nach Typ 2 aus Backend,SG27,PIA,7140,00041,,,Produkt-Code,X [32],"[32] Es sind nur die Messprodukte erlaubt, die in der Codeliste der Konfigurationen im Kapitel 4.5 „Messprodukte für Werte nach Typ 2 aus Backend für LF und NB“ enthalten sind." + 121,Erforderliches Messprodukt für Werte nach Typ 2 aus Backend,SG27,PIA,7143,00041,Z11,,Messprodukt,X, + 122,Erforderliches Produkt Konfigurationserlaubnis für Werte nach Typ 2 aus SMGW,SG27,,,,,,,Soll [24] ∧ [2064] ∧ [26],"[24] Wenn Produkt bestellt werden soll + [26] Wenn in LOC+172 DE3225 (Meldepunkt) die ID einer Messlokation angegeben ist. + [2064] Pro Nachricht ist die SG27 LIN++Z68 (Erforderliches Produkt Konfigurationserlaubnis für Werte nach Typ 2 aus SMGW) maximal einmal anzugeben" + 123,Erforderliches Produkt Konfigurationserlaubnis für Werte nach Typ 2 aus SMGW,SG27,LIN,,00042,,,,Muss, + 124,Erforderliches Produkt Konfigurationserlaubnis für Werte nach Typ 2 aus SMGW,SG27,LIN,1082,00042,,,Positionsnummer,X [903],[903] Format: Möglicher Wert: 1 + 125,Erforderliches Produkt Konfigurationserlaubnis für Werte nach Typ 2 aus SMGW,SG27,LIN,1229,00042,Konfigurationserlaubnis für,,,Z68, + 126,Erforderliches Produkt Konfigurationserlaubnis für Werte nach Typ 2 aus SMGW,SG27,PIA,,00043,,,,Muss, + 127,Erforderliches Produkt Konfigurationserlaubnis für Werte nach Typ 2 aus SMGW,SG27,PIA,4347,00043,,,,5, + 128,Erforderliches Produkt Konfigurationserlaubnis für Werte nach Typ 2 aus SMGW,SG27,PIA,7140,00043,,,Produkt-Code,X [33],"[33] Es sind nur die Messprodukte erlaubt, die in der Codeliste der Konfigurationen im Kapitel 4.4 „Messprodukte mit Konfigurationserlaubnis für Werte nach Typ 2 aus SMGW“ enthalten sind." + 129,Erforderliches Produkt Konfigurationserlaubnis für Werte nach Typ 2 aus SMGW,SG27,PIA,7143,00043,Z12,,Konfigurationsprodukt,X, + 130,Zieladresse URI,SG27,FTX,,00044,,,,Muss [512],[512] Hinweis: Für den Empfang der Werte nach Typ 2 aus dem SMGW. + 131,Zieladresse URI,SG27,FTX,4451,00044,,,,Z17, + 132,Zieladresse URI,SG27,FTX,4440,00044,,,Zieladresse URI für dieBereitstellung der Werte,X, + 133,Zertifikatsaussteller (Issuer),SG27,FTX,,00045,,,,Muss [512],[512] Hinweis: Für den Empfang der Werte nach Typ 2 aus dem SMGW. + 134,Zertifikatsaussteller (Issuer),SG27,FTX,4451,00045,,,,Z24, + 135,Zertifikatsaussteller (Issuer),SG27,FTX,4440,00045,,,Zertifikatsaussteller,X [967],"[967] Format: Zertifikatskörper gemäß X509.1, BSI TR-03109-4" + 136,Zertifikatsnutzer (Subject),SG27,FTX,,00046,,,,Muss [512],[512] Hinweis: Für den Empfang der Werte nach Typ 2 aus dem SMGW. + 137,Zertifikatsnutzer (Subject),SG27,FTX,4451,00046,,,,Z23, + 138,Zertifikatsnutzer (Subject),SG27,FTX,4440,00046,,,Zertifikatsnutzer,X [967],"[967] Format: Zertifikatskörper gemäß X509.1, BSI TR-03109-4" + 139,Änderungsmöglichkeit der Konfiguration im SMGW,SG28,,,,,,,Muss, + 140,Änderungsmöglichkeit der Konfiguration im SMGW,SG28,CCI,,00047,,,,Muss, + 141,Änderungsmöglichkeit der Konfiguration im SMGW,SG28,CCI,7059,00047,Konfiguration im SMGW,,,Z54, + 142,Änderungsmöglichkeit der Konfiguration im SMGW,SG28,CCI,7037,00047,ZF7,,selbstständigeÄnderungsmöglichkeiterforderlich,X, + 143,Änderungsmöglichkeit der Konfiguration im SMGW,SG28,CCI,7037,,ZF8,,selbstständigeÄnderungsmöglichkeitnicht erforderlich,X, + 144,Schwellwerte,SG28,,,,,,,Muss [2065] ∧ [38] ,"[38] Wenn innerhalb derselben SG27 LIN im PIA+5 DE7140 (Erforderliches Produkt Konfigurationserlaubnis für Werte nach Typ 2 aus SMGW) ein Produkt angegeben ist, das in der Codeliste der Konfigurationen im Kapitel 4.4 „Messprodukte mit Konfigurationserlaubnis für Werte nach Typ 2 aus SMGW“ in der Spalte ""Auslöser"" mit dem Wert ""Bei Schwellwertunter- / - überschreitung"" gekennzeichnet ist. + [2065] Diese SG28 ist so oft zu wiederholen, wie zu den unterschiedlichen Messprodukt- Position-Codes zu dem innerhalb derselben SG27 LIN im PIA+5 DE7140 (Erforderliches Produkt Konfigurationserlaubnis für Werte nach Typ 2 aus SMGW) angegebenen Produkt ein Produkt angegeben ist, das in der Codeliste der Konfigurationen im Kapitel 4.4 „Messprodukte mit Konfigurationserlaubnis für Werte nach Typ 2 aus SMGW“ in der Spalte ""Auslöser"" mit dem Wert ""Bei Schwellwertunter- / - überschreitung"" gekennzeichnet ist." + 145,Schwellwerte,SG28,CCI,,00048,,,,Muss, + 146,Schwellwerte,SG28,CCI,7059,00048,,,,Z60, + 147,Schwellwerte,SG28,CCI,7037,00048,,,Messprodukt-Position-Code,X [37],"[37] Es sind nur die Messprodukt-Position-Codes erlaubt, die in der Codeliste der Konfigurationen im Kapitel 4.7 „Art der Werte für Messprodukte nach Typ 2“ enthalten sind." + 148,Schwellwerte,SG28,CCI,7036,00048,,,oberer Schwellwert,X [906] ∧ [962],"[906] Format: max. 3 Nachkommastellen + [962] Format: max. 6 Vorkommastellen" + 149,Schwellwerte,SG28,CCI,7036,00048,,,unterer Schwellwert,X [906] ∧ [962],"[906] Format: max. 3 Nachkommastellen + [962] Format: max. 6 Vorkommastellen" + 150,Abschnitts-Kontrollsegment,,UNS,,00049,,,,Muss, + 151,Abschnitts-Kontrollsegment,,UNS,0081,00049,und Summenteil,,,S, + 152,Nachrichten-Endesegment,,UNT,,00050,,,,Muss, + 153,Nachrichten-Endesegment,,UNT,0074,00050,,,Anzahl der Segmente in einerNachricht,X, + 154,Nachrichten-Endesegment,,UNT,0062,00050,,,Nachrichten-Referenznummer,X, + + ''' +# --- +# name: TestCli.test_kohlrahbi_cli_with_valid_arguments[37000] + ''' + ,Segmentname,Segmentgruppe,Segment,Datenelement,Segment ID,Code,Qualifier,Beschreibung,Bedingungsausdruck,Bedingung + 0,Nachrichten-Kopfsegment,,UNH,,00001,,,,Muss, + 1,Nachrichten-Kopfsegment,,UNH,0062,00001,,,Nachrichten-Referenznummer,X, + 2,Nachrichten-Kopfsegment,,UNH,0065,00001,PARTIN,,Partnerstammdaten,X, + 3,Nachrichten-Kopfsegment,,UNH,0052,00001,D,,Entwurfs-Version,X, + 4,Nachrichten-Kopfsegment,,UNH,0054,00001,20B,,Ausgabe 2020 - B,X, + 5,Nachrichten-Kopfsegment,,UNH,0051,00001,UN,,UN/CEFACT,X, + 6,Nachrichten-Kopfsegment,,UNH,0057,00001,1.0d,,Versionsnummer derzugrundeliegendenBDEW-Nachrichtenbeschreibung,X, + 7,Beginn der Nachricht,,BGM,,00002,,,,Muss, + 8,Beginn der Nachricht,,BGM,1001,00002,10,,Partnerstammdaten,X, + 9,Beginn der Nachricht,,BGM,1004,00002,,,Dokumentennummer,X, + 10,Beginn der Nachricht,,BGM,1373,00002,11,,Dokument nichtverfügbar,S [9],[9] Wenn die Kommunikationsdaten vom Absender nicht mehr aktiv sind. + 11,Nachrichtendatum,,DTM,,00003,,,,Muss, + 12,Nachrichtendatum,,DTM,2005,00003,137,,Dokumenten-/Nachrichtendatum/-zeit,X, + 13,Nachrichtendatum,,DTM,2380,00003,,,"Datum oder Uhrzeit oderZeitspanne, Wert",X [931][494],"[494] Das hier genannte Datum muss der Zeitpunkt sein, zu dem das Dokument erstellt wurde, oder ein Zeitpunkt, der davor liegt. + [931] Format: ZZZ = +00" + 14,Nachrichtendatum,,DTM,2379,00003,303,,CCYYMMDDHHMMZZZ,X, + 15,Prüfidentifikator,SG1,,,,,,,Muss, + 16,Prüfidentifikator,SG1,RFF,,00004,,,,Muss, + 17,Prüfidentifikator,SG1,RFF,1153,00004,Z13,,Prüfidentifikator,X, + 18,Prüfidentifikator,SG1,RFF,1154,00004,37000,,ÜbermittlungKommunikationsdatendes LF,X, + 19,Prüfidentifikator,SG1,RFF,1154,,37001,,ÜbermittlungKommunikationsdatendes NB,, + 20,Prüfidentifikator,SG1,RFF,1154,,37002,,ÜbermittlungKommunikationsdatendes MSB,, + 21,Versionsnummer,SG1,,,,,,,Muss, + 22,Versionsnummer,SG1,RFF,,00005,,,,Muss, + 23,Versionsnummer,SG1,RFF,1153,00005,AGK,,Anwendungsreferenznummer,X, + 24,Versionsnummer,SG1,RFF,1056,00005,,,Versionsnummer,X [908][505],"[505] Wenn eine Vorgängerversion (RFF+ACW) angegeben ist, so muss der Wert in diesem DE1056 mindestens um 1 höher sein, als der Wert aus DE1056 der Vorgängerversion (RFF+ACW). + [908] Format: Mögliche Werte: 1 bis n" + 25,Gültig Ab,SG1,DTM,,00006,,,,Soll [4],[4] Wenn Vorgängerversion vorhanden + 26,Gültig Ab,SG1,DTM,2005,00006,157,,"Gültigkeit, Beginndatum",X, + 27,Gültig Ab,SG1,DTM,2380,00006,,,"Datum oder Uhrzeit oderZeitspanne, Wert",X [UB1], + 28,Gültig Ab,SG1,DTM,2379,00006,303,,CCYYMMDDHHMMZZZ,X, + 29,Vorgängerversion,SG1,,,,,,,Soll [4],[4] Wenn Vorgängerversion vorhanden + 30,Vorgängerversion,SG1,RFF,,00007,,,,Muss, + 31,Vorgängerversion,SG1,RFF,1153,00007,ACW,,Referenznummer einervorangegangenenNachricht,X, + 32,Vorgängerversion,SG1,RFF,1056,00007,,,Versionsnummer,X [908],[908] Format: Mögliche Werte: 1 bis n + 33,MP-ID Absender,SG2,,,,,,,Muss, + 34,MP-ID Absender,SG2,NAD,,00008,,,,Muss, + 35,MP-ID Absender,SG2,NAD,3035,00008,MS,,Dokumenten-/Nachrichtenausstellerbzw. -absender,X, + 36,MP-ID Absender,SG2,NAD,3039,00008,,,MP-ID,X [1],[1] Nur MP-ID aus Sparte Strom + 37,MP-ID Absender,SG2,NAD,3055,00008,9,,GS1,X, + 38,MP-ID Absender,SG2,NAD,3055,,293,,"DE, BDEW",X, + 39,Ansprechpartner,SG3,,,,,,,Kann, + 40,Ansprechpartner,SG3,CTA,,00009,,,,Muss, + 41,Ansprechpartner,SG3,CTA,3139,00009,IC,,Informationskontakt,X, + 42,Ansprechpartner,SG3,CTA,3412,00009,,,Name vom Ansprechpartner,X, + 43,Kommunikationsverbindung,SG3,COM,,00010,,,,Muss, + 44,Kommunikationsverbindung,SG3,COM,3148,00010,,,Nummer / Adresse,X (([939][6])∨ ([940][7]))∧ [502],"[6] wenn im DE3155 im demselben COM der Code EM vorhanden ist + [7] wenn im DE3155 im demselben COM der Code TE / FX / AJ / AL vorhanden ist + [502] Hinweis: Es darf nur eine Information im DE3148 übermittelt werden + [939] Format: Die Zeichenkette muss die Zeichen @ und . enthalten + [940] Format: Die Zeichenkette muss mit dem Zeichen + beginnen und danach dürfen nur noch Ziffern folgen" + 45,Kommunikationsverbindung,SG3,COM,3155,00010,EM,,Elektronische Post,X [1P0..1], + 46,Kommunikationsverbindung,SG3,COM,3155,,FX,,Telefax,X [1P0..1], + 47,Kommunikationsverbindung,SG3,COM,3155,,TE,,Telefon,X [1P0..1], + 48,Kommunikationsverbindung,SG3,COM,3155,,AJ,,weiteres Telefon,X [1P0..1], + 49,Kommunikationsverbindung,SG3,COM,3155,,AL,,Handy,X [1P0..1], + 50,MP-ID Empfänger,SG2,,,,,,,Muss, + 51,MP-ID Empfänger,SG2,NAD,,00011,,,,Muss, + 52,MP-ID Empfänger,SG2,NAD,3035,00011,MR,,Nachrichtenempfänger,X, + 53,MP-ID Empfänger,SG2,NAD,3039,00011,,,MP-ID,X [1],[1] Nur MP-ID aus Sparte Strom + 54,MP-ID Empfänger,SG2,NAD,3055,00011,9,,GS1,X, + 55,MP-ID Empfänger,SG2,NAD,3055,,293,,"DE, BDEW",X, + 56,Abschnitts-Kontrollsegment,,UNS,,00012,,,,Muss, + 57,Abschnitts-Kontrollsegment,,UNS,0081,00012,D,,Trennung von Kopf- undPositionsteil,X, + 58,Name und Adresse des Unternehmens,SG4,,,,,,,Muss [10],[10] Wenn BGM DE1373 = 11 (Dokument nicht verfügbar) nicht vorhanden + 59,Name und Adresse des Unternehmens,SG4,NAD,,00013,,,,Muss, + 60,Name und Adresse des Unternehmens,SG4,NAD,3035,00013,SU,,Lieferant,X, + 61,Name und Adresse des Unternehmens,SG4,NAD,3035,,DDM,,Netzbetreiber,, + 62,Name und Adresse des Unternehmens,SG4,NAD,3035,,DEB,,Messstellenbetreiber,, + 63,Name und Adresse des Unternehmens,SG4,NAD,3036,00013,,,Name,X [506],"[506] Hinweis: Das Datenelement ist so zu füllen, dass sein Inhalt den Vorgaben des USt.- Gesetzes genügt, so dass der Empfänger diese Daten in einer INVOIC nutzen kann." + 64,Name und Adresse des Unternehmens,SG4,NAD,3045,00013,Z02,,Struktur derFirmenbezeichnung,X, + 65,Name und Adresse des Unternehmens,SG4,NAD,3042,00013,,,Straße und Hausnummer oderPostfach,X [506],"[506] Hinweis: Das Datenelement ist so zu füllen, dass sein Inhalt den Vorgaben des USt.- Gesetzes genügt, so dass der Empfänger diese Daten in einer INVOIC nutzen kann." + 66,Name und Adresse des Unternehmens,SG4,NAD,3164,00013,,,Ort,X [506],"[506] Hinweis: Das Datenelement ist so zu füllen, dass sein Inhalt den Vorgaben des USt.- Gesetzes genügt, so dass der Empfänger diese Daten in einer INVOIC nutzen kann." + 67,Name und Adresse des Unternehmens,SG4,NAD,3251,00013,,,Postleitzahl,M [2] ∧[506]S [3] ∧ [506],"[2] Wenn der Code im DE3207 in der ""EDI@Energy Codeliste der europäischen Ländercodes"" in der Spalte ""PLZ vorhanden""" + 68,Name und Adresse des Unternehmens,SG4,NAD,3207,00013,,,"Ländername, Code",X [506],"[506] Hinweis: Das Datenelement ist so zu füllen, dass sein Inhalt den Vorgaben des USt.- Gesetzes genügt, so dass der Empfänger diese Daten in einer INVOIC nutzen kann." + 69,Bankverbindung,SG4,FII,,00014,,,,Muss, + 70,Bankverbindung,SG4,FII,3035,00014,BK,,Kreditinstitut,X, + 71,Bankverbindung,SG4,FII,3194,00014,IBAN,,,X, + 72,Bankverbindung,SG4,FII,3192,00014,,,Name des Kontoinhabers,X, + 73,Bankverbindung,SG4,FII,3192,00014,,,Name des Kontoinhabers,K, + 74,Bankverbindung,SG4,FII,3433,00014,BIC,,,X, + 75,Bankverbindung,SG4,FII,3432,00014,,,Name des Kredinstituts,X, + 76,Internetseite (URL),SG4,FTX,,00015,,,,Muss, + 77,Internetseite (URL),SG4,FTX,4451,00015,Z13,,Internetseite,X, + 78,Internetseite (URL),SG4,FTX,4440,00015,,,Internetseite,X, + 79,Gericht und Handelsregister-Nummer,SG4,FTX,,00016,,,,Soll [3],[3] wenn vorhanden + 80,Gericht und Handelsregister-Nummer,SG4,FTX,4451,00016,Z15,,Gericht undHandelsregister-Nummer,X, + 81,Gericht und Handelsregister-Nummer,SG4,FTX,4440,00016,,,Gericht,X, + 82,Gericht und Handelsregister-Nummer,SG4,FTX,4440,00016,,,Handelsregister-Nummer,X, + 83,"Steuernummer, Umsatzsteuernummer",SG6,,,,,,,Muss [504],[504] Hinweis: Es ist mindestens die + 84,"Steuernummer, Umsatzsteuernummer",SG6,RFF,,00017,,,,Muss, + 85,"Steuernummer, Umsatzsteuernummer",SG6,RFF,1153,00017,VA,,Umsatzsteuernummer,X [2P0..1] ⊻[3P1..1], + 86,"Steuernummer, Umsatzsteuernummer",SG6,RFF,1153,,FC,,Steuernummer,X [2P0..1], + 87,"Steuernummer, Umsatzsteuernummer",SG6,RFF,1154,00017,,,"Referenz, Identifikation",X, + 88,Faxnummer,SG6,RFF,,00018,,,,Kann, + 89,Faxnummer,SG6,RFF,1153,00018,Z25,,Faxnummer,X, + 90,Faxnummer,SG6,RFF,1154,00018,,,Faxnummer,X [940],[940] Format: Die Zeichenkette muss mit dem Zeichen + beginnen und danach dürfen nur noch Ziffern folgen + 91,Erreichbarkeit an Werktagen,SG12,,,,,,,Muss, + 92,Erreichbarkeit an Werktagen,SG12,CCI,,00019,,,,Muss, + 93,Erreichbarkeit an Werktagen,SG12,CCI,7059,00019,Z40,,Erreichbarkeit desUnternehmens,X, + 94,Erreichbarkeit,SG12,DTM,,00020,,,,Muss, + 95,Erreichbarkeit,SG12,DTM,2005,00020,Z36,,Verfügbarkeit Montag,X [1P1..1], + 96,Erreichbarkeit,SG12,DTM,2005,,Z37,,Verfügbarkeit Dienstag,X [1P1..1], + 97,Erreichbarkeit,SG12,DTM,2005,,Z38,,Verfügbarkeit Mittwoch,X [1P1..1], + 98,Erreichbarkeit,SG12,DTM,2005,,Z39,,VerfügbarkeitDonnerstag,X [1P1..1], + 99,Erreichbarkeit,SG12,DTM,2005,,Z40,,Verfügbarkeit Freitag,X [1P1..1], + 100,Erreichbarkeit,SG12,DTM,2005,,Z41,,Mittagspause (=Ausschluss derVerfügbarkeit),X [1P0..1], + 101,Erreichbarkeit,SG12,DTM,2380,00020,,,"Datum oder Uhrzeit oderZeitspanne, Wert",X [503],[503] Hinweis: Angabe erfolgt in gesetzlicher deutscher Zeit + 102,Erreichbarkeit,SG12,DTM,2379,00020,501,,HHMMHHMM,X, + 103,Name und Anschrift Ansprechpartner Übertragungsweg / Datenaustausch,SG4,,,,,,,Muss [10],[10] Wenn BGM DE1373 = 11 (Dokument nicht verfügbar) nicht + 104,Name und Anschrift Ansprechpartner Übertragungsweg / Datenaustausch,SG4,NAD,,00021,,,,Muss, + 105,Name und Anschrift Ansprechpartner Übertragungsweg / Datenaustausch,SG4,NAD,3035,00021,Z10,,AnsprechpartnerÜbertragungsweg /Datenaustausch,X, + 106,Name und Anschrift Ansprechpartner Übertragungsweg / Datenaustausch,SG4,NAD,3036,00021,,,Name,X [500],[500] Hinweis: Es kann der Firmenname eines Dienstleisters oder die identische Firmenbezeichnung aus SG4 NAD+SU / DDM / DEB / Z31 / Z34 / Z35 / Z36 eingetragen werden. + 107,Name und Anschrift Ansprechpartner Übertragungsweg / Datenaustausch,SG4,NAD,3045,00021,Z02,,Struktur derFirmenbezeichnung,X, + 108,Name und Anschrift Ansprechpartner Übertragungsweg / Datenaustausch,SG4,NAD,3042,00021,,,Straße und Hausnummer oderPostfach,X, + 109,Name und Anschrift Ansprechpartner Übertragungsweg / Datenaustausch,SG4,NAD,3164,00021,,,Ort,X, + 110,Name und Anschrift Ansprechpartner Übertragungsweg / Datenaustausch,SG4,NAD,3251,00021,,,Postleitzahl,M [2]S [3],"[2] Wenn der Code im DE3207 in der ""EDI@Energy Codeliste der europäischen Ländercodes"" in der Spalte ""PLZ vorhanden"" ein ""X"" enthält + [3] wenn vorhanden" + 111,Name und Anschrift Ansprechpartner Übertragungsweg / Datenaustausch,SG4,NAD,3207,00021,,,"Ländername, Code",X, + 112,Ansprechpartner,SG7,,,,,,,Muss, + 113,Ansprechpartner,SG7,CTA,,00022,,,,Muss, + 114,Ansprechpartner,SG7,CTA,3139,00022,IC,,Informationskontakt,X, + 115,Ansprechpartner,SG7,CTA,3412,00022,,,Name der organisatorischenEinheit,X [501],"[501] Hinweis: Es darf kein Name einer natürlichen Person übermittelt werden, stattdessen ist die organisatorische Einheit im Unternehmen zu nennen." + 116,Kommunikationsverbindung,SG7,COM,,00023,,,,Muss, + 117,Kommunikationsverbindung,SG7,COM,3148,00023,,,Nummer / Adresse,X (([939][6])∨ ([940][8]))∧ [502],"[6] wenn im DE3155 im demselben COM der Code EM vorhanden ist + [8] wenn im DE3155 im" + 118,Kommunikationsverbindung,SG7,COM,3155,00023,EM,,Elektronische Post,X [1P1..1], + 119,Kommunikationsverbindung,SG7,COM,3155,,TE,,Telefon,X [1P1..1], + 120,Kommunikationsverbindung,SG7,COM,3155,,FX,,Telefax,X [1P0..1], + 121,Name und Anschrift Ansprechpartner Rahmenverträge,SG4,,,,,,,Muss [10] ∧[17],"[10] Wenn BGM DE1373 = 11 (Dokument nicht verfügbar) nicht vorhanden + [17] Wenn MP-ID in SG2 NAD+MR (Nachrichtenempfänger) in der Rolle LF/NB/MSB + [18] Wenn MP-ID in SG2 NAD+MR (Nachrichtenempfänger) in der Rolle LF/MSB + [21] Wenn MP-ID in SG2 NAD+MR (Nachrichtenempfänger) in der Rolle LF/NB/ESA" + 122,Name und Anschrift Ansprechpartner Rahmenverträge,SG4,NAD,,00024,,,,Muss, + 123,Name und Anschrift Ansprechpartner Rahmenverträge,SG4,NAD,3035,00024,Z11,,AnsprechpartnerRahmenverträge,X, + 124,Name und Anschrift Ansprechpartner Rahmenverträge,SG4,NAD,3036,00024,,,Name,X [500],[500] Hinweis: Es kann der Firmenname eines Dienstleisters oder die + 125,Name und Anschrift Ansprechpartner Rahmenverträge,SG4,NAD,3045,00024,Z02,,Struktur derFirmenbezeichnung,X, + 126,Name und Anschrift Ansprechpartner Rahmenverträge,SG4,NAD,3042,00024,,,Straße und Hausnummer oderPostfach,X, + 127,Name und Anschrift Ansprechpartner Rahmenverträge,SG4,NAD,3164,00024,,,Ort,X, + 128,Name und Anschrift Ansprechpartner Rahmenverträge,SG4,NAD,3251,00024,,,Postleitzahl,M [2]S [3],"[2] Wenn der Code im DE3207 in der ""EDI@Energy Codeliste der europäischen Ländercodes"" in der Spalte ""PLZ vorhanden"" ein ""X"" enthält + [3] wenn vorhanden" + 129,Name und Anschrift Ansprechpartner Rahmenverträge,SG4,NAD,3207,00024,,,"Ländername, Code",X, + 130,Ansprechpartner,SG7,,,,,,,Muss, + 131,Ansprechpartner,SG7,CTA,,00025,,,,Muss, + 132,Ansprechpartner,SG7,CTA,3139,00025,IC,,Informationskontakt,X, + 133,Ansprechpartner,SG7,CTA,3412,00025,,,Name der organisatorischenEinheit,X [501],"[501] Hinweis: Es darf kein Name einer natürlichen Person übermittelt werden, stattdessen ist die organisatorische Einheit im Unternehmen zu nennen." + 134,Kommunikationsverbindung,SG7,COM,,00026,,,,Muss, + 135,Kommunikationsverbindung,SG7,COM,3148,00026,,,Nummer / Adresse,X (([939][6])∨ ([940][8]))∧ [502],"[6] wenn im DE3155 im demselben COM der Code EM vorhanden ist + [8] wenn im DE3155 im demselben COM der Code TE / FX vorhanden ist + [502] Hinweis: Es darf nur eine Information im DE3148 übermittelt werden" + 136,Kommunikationsverbindung,SG7,COM,3155,00026,EM,,Elektronische Post,X [1P1..1], + 137,Kommunikationsverbindung,SG7,COM,3155,,TE,,Telefon,X [1P1..1], + 138,Kommunikationsverbindung,SG7,COM,3155,,FX,,Telefax,X [1P0..1], + 139,Name und Anschrift Ansprechpartner Kündigungsprozess,SG4,,,,,,,Muss [5] ∧[10],"[5] Wenn MP-ID in SG2 NAD+MR (Nachrichtenempfänger) in der Rolle LF + [10] Wenn BGM DE1373 = 11 (Dokument nicht verfügbar) nicht vorhanden + [22] Wenn MP-ID in SG2 NAD+MR (Nachrichtenempfänger) in der Rolle MSB" + 140,Name und Anschrift Ansprechpartner Kündigungsprozess,SG4,NAD,,00027,,,,Muss, + 141,Name und Anschrift Ansprechpartner Kündigungsprozess,SG4,NAD,3035,00027,Z12,,AnsprechpartnerKündigungsprozesse,X, + 142,Name und Anschrift Ansprechpartner Kündigungsprozess,SG4,NAD,3036,00027,,,Name,X [500],[500] Hinweis: Es kann der Firmenname eines Dienstleisters oder die identische Firmenbezeichnung aus SG4 NAD+SU / DDM / DEB / Z31 / Z34 / Z35 / Z36 eingetragen werden. + 143,Name und Anschrift Ansprechpartner Kündigungsprozess,SG4,NAD,3045,00027,Z02,,Struktur derFirmenbezeichnung,X, + 144,Name und Anschrift Ansprechpartner Kündigungsprozess,SG4,NAD,3042,00027,,,Straße und Hausnummer oderPostfach,X, + 145,Name und Anschrift Ansprechpartner Kündigungsprozess,SG4,NAD,3164,00027,,,Ort,X, + 146,Name und Anschrift Ansprechpartner Kündigungsprozess,SG4,NAD,3251,00027,,,Postleitzahl,M [2]S [3],[2] Wenn der Code im DE3207 in der + 147,Name und Anschrift Ansprechpartner Kündigungsprozess,SG4,NAD,3207,00027,,,"Ländername, Code",X, + 148,Ansprechpartner,SG7,,,,,,,Muss, + 149,Ansprechpartner,SG7,CTA,,00028,,,,Muss, + 150,Ansprechpartner,SG7,CTA,3139,00028,IC,,Informationskontakt,X, + 151,Ansprechpartner,SG7,CTA,3412,00028,,,Name der organisatorischenEinheit,X [501],"[501] Hinweis: Es darf kein Name einer natürlichen Person übermittelt werden, stattdessen ist die organisatorische Einheit im Unternehmen zu nennen." + 152,Kommunikationsverbindung,SG7,COM,,00029,,,,Muss, + 153,Kommunikationsverbindung,SG7,COM,3148,00029,,,Nummer / Adresse,X (([939][6])∨ ([940][8]))∧ [502],"[6] wenn im DE3155 im demselben COM der Code EM vorhanden ist + [8] wenn im DE3155 im demselben COM der Code TE / FX vorhanden ist + [502] Hinweis: Es darf nur eine Information im DE3148 übermittelt werden + [939] Format: Die Zeichenkette muss die Zeichen @ und . enthalten + [940] Format: Die Zeichenkette muss mit dem Zeichen + beginnen und danach dürfen nur noch Ziffern folgen" + 154,Kommunikationsverbindung,SG7,COM,3155,00029,EM,,Elektronische Post,X [1P1..1], + 155,Kommunikationsverbindung,SG7,COM,3155,,TE,,Telefon,X [1P1..1], + 156,Name und Anschrift Ansprechpartner Wechselprozesse,SG4,,,,,,,Muss [10] ∧[17],"[10] Wenn BGM DE1373 = 11 (Dokument nicht verfügbar) nicht vorhanden + [17] Wenn MP-ID in SG2 NAD+MR (Nachrichtenempfänger) in der Rolle LF/NB/MSB" + 157,Name und Anschrift Ansprechpartner Wechselprozesse,SG4,NAD,,00030,,,,Muss, + 158,Name und Anschrift Ansprechpartner Wechselprozesse,SG4,NAD,3035,00030,Z13,,AnsprechpartnerWechselprozesse,X, + 159,Name und Anschrift Ansprechpartner Wechselprozesse,SG4,NAD,3036,00030,,,Name,X [500],[500] Hinweis: Es kann der Firmenname eines Dienstleisters oder die identische Firmenbezeichnung aus SG4 NAD+SU / DDM / DEB / Z31 / Z34 / Z35 / Z36 eingetragen werden. + 160,Name und Anschrift Ansprechpartner Wechselprozesse,SG4,NAD,3045,00030,Z02,,Struktur derFirmenbezeichnung,X, + 161,Name und Anschrift Ansprechpartner Wechselprozesse,SG4,NAD,3042,00030,,,Straße und Hausnummer oderPostfach,X, + 162,Name und Anschrift Ansprechpartner Wechselprozesse,SG4,NAD,3164,00030,,,Ort,X, + 163,Name und Anschrift Ansprechpartner Wechselprozesse,SG4,NAD,3251,00030,,,Postleitzahl,M [2]S [3],"[2] Wenn der Code im DE3207 in der ""EDI@Energy Codeliste der europäischen Ländercodes"" in der Spalte ""PLZ vorhanden"" ein ""X"" enthält + [3] wenn vorhanden" + 164,Name und Anschrift Ansprechpartner Wechselprozesse,SG4,NAD,3207,00030,,,"Ländername, Code",X, + 165,Ansprechpartner,SG7,,,,,,,Muss, + 166,Ansprechpartner,SG7,CTA,,00031,,,,Muss, + 167,Ansprechpartner,SG7,CTA,3139,00031,IC,,Informationskontakt,X, + 168,Ansprechpartner,SG7,CTA,3412,00031,,,Name der organisatorischenEinheit,X [501],"[501] Hinweis: Es darf kein Name einer natürlichen Person übermittelt werden, stattdessen ist die" + 169,Kommunikationsverbindung,SG7,COM,,00032,,,,Muss, + 170,Kommunikationsverbindung,SG7,COM,3148,00032,,,Nummer / Adresse,X (([939][6])∨ ([940][8]))∧ [502],"[6] wenn im DE3155 im demselben COM der Code EM vorhanden ist + [8] wenn im DE3155 im demselben COM der Code TE / FX vorhanden ist + [502] Hinweis: Es darf nur eine Information im DE3148 übermittelt werden + [939] Format: Die Zeichenkette muss die Zeichen @ und . enthalten + [940] Format: Die Zeichenkette muss mit dem Zeichen + beginnen und danach dürfen nur noch Ziffern folgen" + 171,Kommunikationsverbindung,SG7,COM,3155,00032,EM,,Elektronische Post,X [1P1..1], + 172,Kommunikationsverbindung,SG7,COM,3155,,TE,,Telefon,X [1P1..1], + 173,Kommunikationsverbindung,SG7,COM,3155,,FX,,Telefax,X [1P0..1], + 174,Name und Anschrift Ansprechpartner Stammdatenprozesse,SG4,,,,,,,Muss [10],"[10] Wenn BGM DE1373 = 11 (Dokument nicht verfügbar) nicht vorhanden + [19] Wenn MP-ID in SG2 NAD+MR (Nachrichtenempfänger) in der Rolle LF/MSB/ NB/ÜNB" + 175,Name und Anschrift Ansprechpartner Stammdatenprozesse,SG4,NAD,,00033,,,,Muss, + 176,Name und Anschrift Ansprechpartner Stammdatenprozesse,SG4,NAD,3035,00033,Z14,,AnsprechpartnerStammdatenprozesse,X, + 177,Name und Anschrift Ansprechpartner Stammdatenprozesse,SG4,NAD,3036,00033,,,Name,X [500],[500] Hinweis: Es kann der Firmenname eines Dienstleisters oder die identische Firmenbezeichnung aus SG4 NAD+SU / DDM / DEB / Z31 / Z34 / Z35 / Z36 eingetragen werden. + 178,Name und Anschrift Ansprechpartner Stammdatenprozesse,SG4,NAD,3045,00033,Z02,,Struktur derFirmenbezeichnung,X, + 179,Name und Anschrift Ansprechpartner Stammdatenprozesse,SG4,NAD,3042,00033,,,Straße und Hausnummer oderPostfach,X, + 180,Name und Anschrift Ansprechpartner Stammdatenprozesse,SG4,NAD,3164,00033,,,Ort,X, + 181,Name und Anschrift Ansprechpartner Stammdatenprozesse,SG4,NAD,3251,00033,,,Postleitzahl,M [2]S [3],"[2] Wenn der Code im DE3207 in der ""EDI@Energy Codeliste der europäischen Ländercodes"" in der Spalte ""PLZ vorhanden"" ein ""X"" enthält + [3] wenn vorhanden" + 182,Name und Anschrift Ansprechpartner Stammdatenprozesse,SG4,NAD,3207,00033,,,"Ländername, Code",X, + 183,Ansprechpartner,SG7,,,,,,,Muss, + 184,Ansprechpartner,SG7,CTA,,00034,,,,Muss, + 185,Ansprechpartner,SG7,CTA,3139,00034,IC,,Informationskontakt,X, + 186,Ansprechpartner,SG7,CTA,3412,00034,,,Name der organisatorischenEinheit,X [501],"[501] Hinweis: Es darf kein Name einer natürlichen Person übermittelt werden, stattdessen ist die organisatorische Einheit im Unternehmen zu nennen." + 187,Kommunikationsverbindung,SG7,COM,,00035,,,,Muss, + 188,Kommunikationsverbindung,SG7,COM,3148,00035,,,Nummer / Adresse,X (([939][6])∨ ([940][8]))∧ [502],"[6] wenn im DE3155 im demselben COM der Code EM vorhanden ist + [8] wenn im DE3155 im demselben COM der Code TE / FX vorhanden ist + [502] Hinweis: Es darf" + 189,Kommunikationsverbindung,SG7,COM,3155,00035,EM,,Elektronische Post,X [1P1..1], + 190,Kommunikationsverbindung,SG7,COM,3155,,TE,,Telefon,X [1P1..1], + 191,Kommunikationsverbindung,SG7,COM,3155,,FX,,Telefax,X [1P0..1], + 192,Name und Anschrift Ansprechpartner Einspeiseprozesse,SG4,,,,,,,Muss [10] ∧[17],"[10] Wenn BGM DE1373 = 11 (Dokument nicht verfügbar) nicht vorhanden + [17] Wenn MP-ID in SG2 NAD+MR (Nachrichtenempfänger) in der Rolle LF/NB/MSB + [18] Wenn MP-ID in SG2 NAD+MR (Nachrichtenempfänger) in der Rolle LF/MSB + [23] Wenn MP-ID in SG2 NAD+MR (Nachrichtenempfänger) in der Rolle NB/ÜNB" + 193,Name und Anschrift Ansprechpartner Einspeiseprozesse,SG4,NAD,,00036,,,,Muss, + 194,Name und Anschrift Ansprechpartner Einspeiseprozesse,SG4,NAD,3035,00036,Z16,,AnsprechpartnerEinspeiseprozesse,X, + 195,Name und Anschrift Ansprechpartner Einspeiseprozesse,SG4,NAD,3036,00036,,,Name,X [500],[500] Hinweis: Es kann der Firmenname eines Dienstleisters oder die identische Firmenbezeichnung aus SG4 NAD+SU / DDM / DEB / Z31 / Z34 / Z35 / Z36 eingetragen werden. + 196,Name und Anschrift Ansprechpartner Einspeiseprozesse,SG4,NAD,3045,00036,Z02,,Struktur derFirmenbezeichnung,X, + 197,Name und Anschrift Ansprechpartner Einspeiseprozesse,SG4,NAD,3042,00036,,,Straße und Hausnummer oderPostfach,X, + 198,Name und Anschrift Ansprechpartner Einspeiseprozesse,SG4,NAD,3164,00036,,,Ort,X, + 199,Name und Anschrift Ansprechpartner Einspeiseprozesse,SG4,NAD,3251,00036,,,Postleitzahl,M [2]S [3],"[2] Wenn der Code im DE3207 in der ""EDI@Energy Codeliste der europäischen Ländercodes"" in der Spalte ""PLZ vorhanden"" ein ""X"" enthält + [3] wenn vorhanden" + 200,Name und Anschrift Ansprechpartner Einspeiseprozesse,SG4,NAD,3207,00036,,,"Ländername, Code",X, + 201,Ansprechpartner,SG7,,,,,,,Muss, + 202,Ansprechpartner,SG7,CTA,,00037,,,,Muss, + 203,Ansprechpartner,SG7,CTA,3139,00037,IC,,Informationskontakt,X, + 204,Ansprechpartner,SG7,CTA,3412,00037,,,Name der organisatorischenEinheit,X [501],"[501] Hinweis: Es darf kein Name einer natürlichen Person übermittelt werden, stattdessen ist die organisatorische Einheit im Unternehmen zu nennen." + 205,Kommunikationsverbindung,SG7,COM,,00038,,,,Muss, + 206,Kommunikationsverbindung,SG7,COM,3148,00038,,,Nummer / Adresse,X (([939][6])∨ ([940][8]))∧ [502],"[6] wenn im DE3155 im demselben COM der Code EM vorhanden ist + [8] wenn im DE3155 im demselben COM der Code TE / FX vorhanden ist + [502] Hinweis: Es darf nur eine Information im DE3148 übermittelt werden + [939] Format: Die Zeichenkette muss die Zeichen @ und . enthalten " + 207,Kommunikationsverbindung,SG7,COM,3155,00038,EM,,Elektronische Post,X [1P1..1], + 208,Kommunikationsverbindung,SG7,COM,3155,,TE,,Telefon,X [1P1..1], + 209,Kommunikationsverbindung,SG7,COM,3155,,FX,,Telefax,X [1P0..1], + 210,Name und Anschrift Ansprechpartner Abrechnungsprozesse,SG4,,,,,,,Muss [10] ∧[17],"[10] Wenn BGM DE1373 = 11 (Dokument nicht verfügbar) nicht vorhanden + [17] Wenn MP-ID in SG2 NAD+MR (Nachrichtenempfänger) in der Rolle LF/NB/MSB + [18] Wenn MP-ID in SG2 NAD+MR (Nachrichtenempfänger) in der Rolle LF/MSB + [24] Wenn MP-ID in SG2 NAD+MR (Nachrichtenempfänger) in der Rolle NB/LF/ MSB/ESA" + 211,Name und Anschrift Ansprechpartner Abrechnungsprozesse,SG4,NAD,,00039,,,,Muss, + 212,Name und Anschrift Ansprechpartner Abrechnungsprozesse,SG4,NAD,3035,00039,Z17,,AnsprechpartnerAbrechnungsprozesse,X, + 213,Name und Anschrift Ansprechpartner Abrechnungsprozesse,SG4,NAD,3036,00039,,,Name,X [500],[500] Hinweis: Es kann der Firmenname eines Dienstleisters oder die identische Firmenbezeichnung aus SG4 NAD+SU / DDM / DEB / Z31 / Z34 / Z35 / Z36 eingetragen werden. + 214,Name und Anschrift Ansprechpartner Abrechnungsprozesse,SG4,NAD,3045,00039,Z02,,Struktur derFirmenbezeichnung,X, + 215,Name und Anschrift Ansprechpartner Abrechnungsprozesse,SG4,NAD,3042,00039,,,Straße und Hausnummer oderPostfach,X, + 216,Name und Anschrift Ansprechpartner Abrechnungsprozesse,SG4,NAD,3164,00039,,,Ort,X, + 217,Name und Anschrift Ansprechpartner Abrechnungsprozesse,SG4,NAD,3251,00039,,,Postleitzahl,M [2]S [3],[2] Wenn der Code im DE3207 in der + 218,Name und Anschrift Ansprechpartner Abrechnungsprozesse,SG4,NAD,3207,00039,,,"Ländername, Code",X, + 219,Ansprechpartner,SG7,,,,,,,Muss, + 220,Ansprechpartner,SG7,CTA,,00040,,,,Muss, + 221,Ansprechpartner,SG7,CTA,3139,00040,IC,,Informationskontakt,X, + 222,Ansprechpartner,SG7,CTA,3412,00040,,,Name der organisatorischenEinheit,X [501],"[501] Hinweis: Es darf kein Name einer natürlichen Person übermittelt werden, stattdessen ist die organisatorische Einheit im Unternehmen zu nennen." + 223,Kommunikationsverbindung,SG7,COM,,00041,,,,Muss, + 224,Kommunikationsverbindung,SG7,COM,3148,00041,,,Nummer / Adresse,X (([939][6])∨ ([940][8]))∧ [502],"[6] wenn im DE3155 im demselben COM der Code EM vorhanden ist + [8] wenn im DE3155 im demselben COM der Code TE / FX vorhanden ist + [502] Hinweis: Es darf nur eine Information im DE3148 übermittelt werden + [939] Format: Die Zeichenkette muss die Zeichen @ und . enthalten + [940] Format: Die Zeichenkette muss mit dem Zeichen + beginnen und danach dürfen nur noch Ziffern folgen" + 225,Kommunikationsverbindung,SG7,COM,3155,00041,EM,,Elektronische Post,X [1P1..1], + 226,Kommunikationsverbindung,SG7,COM,3155,,TE,,Telefon,X [1P1..1], + 227,Name und Anschrift Ansprechpartner MMMA- Prozesse,SG4,,,,,,,Muss [10] ∧[17],"[10] Wenn BGM DE1373 = 11 (Dokument nicht verfügbar) nicht vorhanden + [17] Wenn MP-ID in SG2 NAD+MR (Nachrichtenempfänger) in der Rolle LF/NB/MSB + [20] Wenn MP-ID in SG2 NAD+MR (Nachrichtenempfänger) in der Rolle LF/MSB/ÜNB" + 228,Name und Anschrift Ansprechpartner MMMA- Prozesse,SG4,NAD,,00042,,,,Muss, + 229,Name und Anschrift Ansprechpartner MMMA- Prozesse,SG4,NAD,3035,00042,Z18,,AnsprechpartnerMMMA-Prozesse,X, + 230,Name und Anschrift Ansprechpartner MMMA- Prozesse,SG4,NAD,3036,00042,,,Name,X [500],[500] Hinweis: Es kann der Firmenname eines Dienstleisters oder die identische Firmenbezeichnung aus SG4 NAD+SU / DDM / DEB / Z31 / Z34 / Z35 / Z36 eingetragen werden. + 231,Name und Anschrift Ansprechpartner MMMA- Prozesse,SG4,NAD,3045,00042,Z02,,Struktur derFirmenbezeichnung,X, + 232,Name und Anschrift Ansprechpartner MMMA- Prozesse,SG4,NAD,3042,00042,,,Straße und Hausnummer oderPostfach,X, + 233,Name und Anschrift Ansprechpartner MMMA- Prozesse,SG4,NAD,3164,00042,,,Ort,X, + 234,Name und Anschrift Ansprechpartner MMMA- Prozesse,SG4,NAD,3251,00042,,,Postleitzahl,M [2]S [3],"[2] Wenn der Code im DE3207 in der ""EDI@Energy Codeliste der europäischen Ländercodes"" in der Spalte ""PLZ vorhanden"" ein ""X"" enthält + [3] wenn vorhanden" + 235,Name und Anschrift Ansprechpartner MMMA- Prozesse,SG4,NAD,3207,00042,,,"Ländername, Code",X, + 236,Ansprechpartner,SG7,,,,,,,Muss, + 237,Ansprechpartner,SG7,CTA,,00043,,,,Muss, + 238,Ansprechpartner,SG7,CTA,3139,00043,IC,,Informationskontakt,X, + 239,Ansprechpartner,SG7,CTA,3412,00043,,,Name der organisatorischenEinheit,X [501],"[501] Hinweis: Es darf kein Name einer natürlichen Person übermittelt werden, stattdessen ist die organisatorische Einheit im Unternehmen zu nennen." + 240,Kommunikationsverbindung,SG7,COM,,00044,,,,Muss, + 241,Kommunikationsverbindung,SG7,COM,3148,00044,,,Nummer / Adresse,X (([939][6])∨ ([940][8]))∧ [502],"[6] wenn im DE3155 im demselben COM der Code EM vorhanden ist + [8] wenn im DE3155 im demselben COM der Code TE / FX vorhanden ist + [502] Hinweis: Es darf nur eine Information im DE3148 übermittelt werden + [939] Format: Die Zeichenkette muss die Zeichen @ und . enthalten + [940] Format: Die Zeichenkette muss mit dem Zeichen + beginnen und danach dürfen nur noch Ziffern folgen" + 242,Kommunikationsverbindung,SG7,COM,3155,00044,EM,,Elektronische Post,X [1P1..1], + 243,Kommunikationsverbindung,SG7,COM,3155,,TE,,Telefon,X [1P1..1], + 244,Kommunikationsverbindung,SG7,COM,3155,,FX,,Telefax,X [1P0..1], + 245,Name und Anschrift Bewegungsdaten,SG4,,,,,,,Muss [10],"[10] Wenn BGM DE1373 = 11 (Dokument nicht verfügbar) nicht vorhanden + [19] Wenn MP-ID in SG2 NAD+MR (Nachrichtenempfänger) in der Rolle LF/MSB/" + 246,Name und Anschrift Bewegungsdaten,SG4,NAD,,00045,,,,Muss, + 247,Name und Anschrift Bewegungsdaten,SG4,NAD,3035,00045,Z19,,AnsprechpartnerBewegungsdaten,X, + 248,Name und Anschrift Bewegungsdaten,SG4,NAD,3036,00045,,,Name,X [500],[500] Hinweis: Es kann der Firmenname eines Dienstleisters oder die identische Firmenbezeichnung aus SG4 NAD+SU / DDM / DEB / Z31 / Z34 / Z35 / Z36 eingetragen werden. + 249,Name und Anschrift Bewegungsdaten,SG4,NAD,3045,00045,Z02,,Struktur derFirmenbezeichnung,X, + 250,Name und Anschrift Bewegungsdaten,SG4,NAD,3042,00045,,,Straße und Hausnummer oderPostfach,X, + 251,Name und Anschrift Bewegungsdaten,SG4,NAD,3164,00045,,,Ort,X, + 252,Name und Anschrift Bewegungsdaten,SG4,NAD,3251,00045,,,Postleitzahl,M [2]S [3],"[2] Wenn der Code im DE3207 in der ""EDI@Energy Codeliste der europäischen Ländercodes"" in der Spalte ""PLZ vorhanden"" ein ""X"" enthält + [3] wenn vorhanden" + 253,Name und Anschrift Bewegungsdaten,SG4,NAD,3207,00045,,,"Ländername, Code",X, + 254,Ansprechpartner,SG7,,,,,,,Muss, + 255,Ansprechpartner,SG7,CTA,,00046,,,,Muss, + 256,Ansprechpartner,SG7,CTA,3139,00046,IC,,Informationskontakt,X, + 257,Ansprechpartner,SG7,CTA,3412,00046,,,Name der organisatorischenEinheit,X [501],"[501] Hinweis: Es darf kein Name einer natürlichen Person übermittelt werden, stattdessen ist die organisatorische Einheit im Unternehmen zu nennen." + 258,Kommunikationsverbindung,SG7,COM,,00047,,,,Muss, + 259,Kommunikationsverbindung,SG7,COM,3148,00047,,,Nummer / Adresse,X (([939][6])∨ ([940][8]))∧ [502],"[6] wenn im DE3155 im demselben COM der Code EM vorhanden ist + [8] wenn im DE3155 im demselben COM der" + 260,Kommunikationsverbindung,SG7,COM,3155,00047,EM,,Elektronische Post,X [1P1..1], + 261,Kommunikationsverbindung,SG7,COM,3155,,TE,,Telefon,X [1P1..1], + 262,Kommunikationsverbindung,SG7,COM,3155,,FX,,Telefax,X [1P0..1], + 263,Name und Anschrift Ansprechpartner Prozesse zur Unterbrechung und Wiederherstellung der Anschlussnutzung,SG4,,,,,,,Muss [10] ∧[17],"[10] Wenn BGM DE1373 = 11 (Dokument nicht verfügbar) nicht vorhanden + [17] Wenn MP-ID in SG2 NAD+MR (Nachrichtenempfänger) in der Rolle LF/NB/MSB + [20] Wenn MP-ID in SG2 NAD+MR (Nachrichtenempfänger) in der Rolle LF/MSB/ÜNB" + 264,Name und Anschrift Ansprechpartner Prozesse zur Unterbrechung und Wiederherstellung der Anschlussnutzung,SG4,NAD,,00048,,,,Muss, + 265,Name und Anschrift Ansprechpartner Prozesse zur Unterbrechung und Wiederherstellung der Anschlussnutzung,SG4,NAD,3035,00048,Z20,,AnsprechpartnerSperr-/Entsperrprozesse,X, + 266,Name und Anschrift Ansprechpartner Prozesse zur Unterbrechung und Wiederherstellung der Anschlussnutzung,SG4,NAD,3036,00048,,,Name,X [500],[500] Hinweis: Es kann der Firmenname eines Dienstleisters oder die identische Firmenbezeichnung aus SG4 NAD+SU / DDM / DEB / Z31 / Z34 / Z35 / + 267,Name und Anschrift Ansprechpartner Prozesse zur Unterbrechung und Wiederherstellung der Anschlussnutzung,SG4,NAD,3045,00048,Z02,,Struktur derFirmenbezeichnung,X, + 268,Name und Anschrift Ansprechpartner Prozesse zur Unterbrechung und Wiederherstellung der Anschlussnutzung,SG4,NAD,3042,00048,,,Straße und Hausnummer oderPostfach,X, + 269,Name und Anschrift Ansprechpartner Prozesse zur Unterbrechung und Wiederherstellung der Anschlussnutzung,SG4,NAD,3164,00048,,,Ort,X, + 270,Name und Anschrift Ansprechpartner Prozesse zur Unterbrechung und Wiederherstellung der Anschlussnutzung,SG4,NAD,3251,00048,,,Postleitzahl,M [2]S [3],"[2] Wenn der Code im DE3207 in der ""EDI@Energy Codeliste der europäischen Ländercodes"" in der Spalte ""PLZ vorhanden"" ein ""X"" enthält + [3] wenn vorhanden" + 271,Name und Anschrift Ansprechpartner Prozesse zur Unterbrechung und Wiederherstellung der Anschlussnutzung,SG4,NAD,3207,00048,,,"Ländername, Code",X, + 272,Ansprechpartner,SG7,,,,,,,Muss, + 273,Ansprechpartner,SG7,CTA,,00049,,,,Muss, + 274,Ansprechpartner,SG7,CTA,3139,00049,IC,,Informationskontakt,X, + 275,Ansprechpartner,SG7,CTA,3412,00049,,,Name der organisatorischenEinheit,X [501],"[501] Hinweis: Es darf kein Name einer natürlichen Person übermittelt werden, stattdessen ist die organisatorische Einheit im Unternehmen zu nennen." + 276,Kommunikationsverbindung,SG7,COM,,00050,,,,Muss, + 277,Kommunikationsverbindung,SG7,COM,3148,00050,,,Nummer / Adresse,X (([939][6])∨ ([940][8]))∧ [502],"[6] wenn im DE3155 im demselben COM der Code EM vorhanden ist + [8] wenn im DE3155 im demselben COM der Code TE / FX vorhanden ist + [502] Hinweis: Es darf nur eine Information im DE3148 übermittelt werden + [939] Format: Die Zeichenkette muss die Zeichen @ und ." + 278,Kommunikationsverbindung,SG7,COM,3155,00050,EM,,Elektronische Post,X [1P1..1], + 279,Kommunikationsverbindung,SG7,COM,3155,,TE,,Telefon,X [1P1..1], + 280,Kommunikationsverbindung,SG7,COM,3155,,FX,,Telefax,X [1P0..1], + 281,Name und Anschrift Ansprechpartner Bilanzierungsprozesse / Bilanzkreismanagement,SG4,,,,,,,Muss [10],[10] Wenn BGM DE1373 = 11 (Dokument nicht verfügbar) nicht vorhanden + 282,Name und Anschrift Ansprechpartner Bilanzierungsprozesse / Bilanzkreismanagement,SG4,NAD,,00051,,,,Muss, + 283,Name und Anschrift Ansprechpartner Bilanzierungsprozesse / Bilanzkreismanagement,SG4,NAD,3035,00051,Z21,,AnsprechpartnerBilanzierungsprozesse /Bilanzkreismanagement,X, + 284,Name und Anschrift Ansprechpartner Bilanzierungsprozesse / Bilanzkreismanagement,SG4,NAD,3036,00051,,,Name,X [500],[500] Hinweis: Es kann der Firmenname eines Dienstleisters oder die identische Firmenbezeichnung aus SG4 NAD+SU / DDM / DEB / Z31 / Z34 / Z35 / Z36 eingetragen werden. + 285,Name und Anschrift Ansprechpartner Bilanzierungsprozesse / Bilanzkreismanagement,SG4,NAD,3045,00051,Z02,,Struktur derFirmenbezeichnung,X, + 286,Name und Anschrift Ansprechpartner Bilanzierungsprozesse / Bilanzkreismanagement,SG4,NAD,3042,00051,,,Straße und Hausnummer oderPostfach,X, + 287,Name und Anschrift Ansprechpartner Bilanzierungsprozesse / Bilanzkreismanagement,SG4,NAD,3164,00051,,,Ort,X, + 288,Name und Anschrift Ansprechpartner Bilanzierungsprozesse / Bilanzkreismanagement,SG4,NAD,3251,00051,,,Postleitzahl,M [2]S [3],"[2] Wenn der Code im DE3207 in der ""EDI@Energy Codeliste der europäischen Ländercodes"" in der Spalte ""PLZ vorhanden"" ein ""X"" enthält + [3] wenn vorhanden" + 289,Name und Anschrift Ansprechpartner Bilanzierungsprozesse / Bilanzkreismanagement,SG4,NAD,3207,00051,,,"Ländername, Code",X, + 290,Ansprechpartner,SG7,,,,,,,Muss, + 291,Ansprechpartner,SG7,CTA,,00052,,,,Muss, + 292,Ansprechpartner,SG7,CTA,3139,00052,IC,,Informationskontakt,X, + 293,Ansprechpartner,SG7,CTA,3412,00052,,,Name der organisatorischenEinheit,X [501],"[501] Hinweis: Es darf kein Name einer natürlichen Person übermittelt werden, stattdessen ist die organisatorische Einheit im Unternehmen zu nennen." + 294,Kommunikationsverbindung,SG7,COM,,00053,,,,Muss, + 295,Kommunikationsverbindung,SG7,COM,3148,00053,,,Nummer / Adresse,X (([939][6])∨ ([940][8]))∧ [502],"[6] wenn im DE3155 im demselben COM der Code EM vorhanden ist + [8] wenn im DE3155 im demselben COM der Code TE / FX vorhanden ist + [502] Hinweis: Es darf nur eine Information im DE3148 übermittelt werden + [939] Format: Die Zeichenkette muss die Zeichen @ und . enthalten + [940] Format: Die Zeichenkette muss mit dem Zeichen + beginnen und danach dürfen nur noch Ziffern folgen" + 296,Kommunikationsverbindung,SG7,COM,3155,00053,EM,,Elektronische Post,X [1P1..1], + 297,Kommunikationsverbindung,SG7,COM,3155,,TE,,Telefon,X [1P1..1], + 298,Kommunikationsverbindung,SG7,COM,3155,,FX,,Telefax,X [1P0..1], + 299,Name und Anschrift Ansprechpartner Technischer Netzanschluss für Neuanlagen und Anlagenumbau,SG4,,,,,,,,[10] Wenn BGM DE1373 = 11 (Dokument nicht verfügbar) nicht vorhanden + 300,Name und Anschrift Ansprechpartner Technischer Netzanschluss für Neuanlagen und Anlagenumbau,SG4,NAD,,00054,,,,, + 301,Name und Anschrift Ansprechpartner Technischer Netzanschluss für Neuanlagen und Anlagenumbau,SG4,NAD,3035,00054,Z33,,AnsprechpartnertechnischerNetzanschluss fürNeuanlagen undAnlagenumbau,, + 302,Name und Anschrift Ansprechpartner Technischer Netzanschluss für Neuanlagen und Anlagenumbau,SG4,NAD,3036,00054,,,Name,,[500] Hinweis: Es kann der Firmenname eines Dienstleisters oder die identische Firmenbezeichnung aus SG4 NAD+SU / DDM / DEB / Z31 / Z34 / Z35 / Z36 eingetragen werden. + 303,Name und Anschrift Ansprechpartner Technischer Netzanschluss für Neuanlagen und Anlagenumbau,SG4,NAD,3045,00054,Z02,,Struktur derFirmenbezeichnung,, + 304,Name und Anschrift Ansprechpartner Technischer Netzanschluss für Neuanlagen und Anlagenumbau,SG4,NAD,3042,00054,,,Straße und Hausnummer oderPostfach,, + 305,Name und Anschrift Ansprechpartner Technischer Netzanschluss für Neuanlagen und Anlagenumbau,SG4,NAD,3164,00054,,,Ort,, + 306,Name und Anschrift Ansprechpartner Technischer Netzanschluss für Neuanlagen und Anlagenumbau,SG4,NAD,3251,00054,,,Postleitzahl,,"[2] Wenn der Code im DE3207 in der ""EDI@Energy Codeliste der europäischen Ländercodes"" in der Spalte ""PLZ vorhanden"" ein ""X"" enthält + [3] wenn vorhanden" + 307,Name und Anschrift Ansprechpartner Technischer Netzanschluss für Neuanlagen und Anlagenumbau,SG4,NAD,3207,00054,,,"Ländername, Code",, + 308,Ansprechpartner,SG7,,,,,,,, + 309,Ansprechpartner,SG7,CTA,,00055,,,,, + 310,Ansprechpartner,SG7,CTA,3139,00055,IC,,Informationskontakt,, + 311,Ansprechpartner,SG7,CTA,3412,00055,,,Name der organisatorischenEinheit,,"[501] Hinweis: Es darf kein Name einer natürlichen Person übermittelt werden, stattdessen ist die organisatorische Einheit im Unternehmen zu nennen." + 312,Kommunikationsverbindung,SG7,COM,,00056,,,,, + 313,Kommunikationsverbindung,SG7,COM,3148,00056,,,Nummer / Adresse,,"[6] wenn im DE3155 im demselben COM der Code EM vorhanden ist + [8] wenn im DE3155 im demselben COM der Code TE / FX vorhanden ist + [502] Hinweis: Es darf nur eine Information im DE3148 übermittelt werden + [939] Format: Die Zeichenkette muss die Zeichen @ und . enthalten + [940] Format: Die Zeichenkette muss mit dem Zeichen + beginnen und danach dürfen nur noch Ziffern folgen" + 314,Kommunikationsverbindung,SG7,COM,3155,00056,EM,,Elektronische Post,, + 315,Kommunikationsverbindung,SG7,COM,3155,,TE,,Telefon,, + 316,Kommunikationsverbindung,SG7,COM,3155,,FX,,Telefax,, + 317,Nachrichten-Endesegment,,UNT,,00061,,,,Muss, + 318,Nachrichten-Endesegment,,UNT,0074,00061,,,Anzahl der Segmente in einerNachricht,X, + 319,Nachrichten-Endesegment,,UNT,0062,00061,,,Nachrichten-Referenznummer,X, + + ''' +# --- +# name: TestCli.test_kohlrahbi_cli_with_valid_arguments[37002] + ''' + ,Segmentname,Segmentgruppe,Segment,Datenelement,Segment ID,Code,Qualifier,Beschreibung,Bedingungsausdruck,Bedingung + 0,Nachrichten-Kopfsegment,,UNH,,00001,,,,Muss, + 1,Nachrichten-Kopfsegment,,UNH,0062,00001,,,Nachrichten-Referenznummer,X, + 2,Nachrichten-Kopfsegment,,UNH,0065,00001,PARTIN,,Partnerstammdaten,X, + 3,Nachrichten-Kopfsegment,,UNH,0052,00001,D,,Entwurfs-Version,X, + 4,Nachrichten-Kopfsegment,,UNH,0054,00001,20B,,Ausgabe 2020 - B,X, + 5,Nachrichten-Kopfsegment,,UNH,0051,00001,UN,,UN/CEFACT,X, + 6,Nachrichten-Kopfsegment,,UNH,0057,00001,1.0d,,Versionsnummer derzugrundeliegendenBDEW-Nachrichtenbeschreibung,X, + 7,Beginn der Nachricht,,BGM,,00002,,,,Muss, + 8,Beginn der Nachricht,,BGM,1001,00002,10,,Partnerstammdaten,X, + 9,Beginn der Nachricht,,BGM,1004,00002,,,Dokumentennummer,X, + 10,Beginn der Nachricht,,BGM,1373,00002,11,,Dokument nichtverfügbar,S [9],[9] Wenn die Kommunikationsdaten vom Absender nicht mehr aktiv sind. + 11,Nachrichtendatum,,DTM,,00003,,,,Muss, + 12,Nachrichtendatum,,DTM,2005,00003,137,,Dokumenten-/Nachrichtendatum/-zeit,X, + 13,Nachrichtendatum,,DTM,2380,00003,,,"Datum oder Uhrzeit oderZeitspanne, Wert",X [931][494],"[494] Das hier genannte Datum muss der Zeitpunkt sein, zu dem das Dokument erstellt wurde, oder ein Zeitpunkt, der davor liegt. + [931] Format: ZZZ = +00" + 14,Nachrichtendatum,,DTM,2379,00003,303,,CCYYMMDDHHMMZZZ,X, + 15,Prüfidentifikator,SG1,,,,,,,Muss, + 16,Prüfidentifikator,SG1,RFF,,00004,,,,Muss, + 17,Prüfidentifikator,SG1,RFF,1153,00004,Z13,,Prüfidentifikator,X, + 18,Prüfidentifikator,SG1,RFF,1154,00004,37000,,ÜbermittlungKommunikationsdatendes LF,, + 19,Prüfidentifikator,SG1,RFF,1154,,37001,,ÜbermittlungKommunikationsdatendes NB,, + 20,Prüfidentifikator,SG1,RFF,1154,,37002,,ÜbermittlungKommunikationsdatendes MSB,X, + 21,Versionsnummer,SG1,,,,,,,Muss, + 22,Versionsnummer,SG1,RFF,,00005,,,,Muss, + 23,Versionsnummer,SG1,RFF,1153,00005,AGK,,Anwendungsreferenznummer,X, + 24,Versionsnummer,SG1,RFF,1056,00005,,,Versionsnummer,X [908][505],"[505] Wenn eine Vorgängerversion (RFF+ACW) angegeben ist, so muss der Wert in diesem DE1056 mindestens um 1 höher sein, als der Wert aus DE1056 der Vorgängerversion (RFF+ACW). + [908] Format: Mögliche Werte: 1 bis n" + 25,Gültig Ab,SG1,DTM,,00006,,,,Soll [4],[4] Wenn Vorgängerversion vorhanden + 26,Gültig Ab,SG1,DTM,2005,00006,157,,"Gültigkeit, Beginndatum",X, + 27,Gültig Ab,SG1,DTM,2380,00006,,,"Datum oder Uhrzeit oderZeitspanne, Wert",X [UB1], + 28,Gültig Ab,SG1,DTM,2379,00006,303,,CCYYMMDDHHMMZZZ,X, + 29,Vorgängerversion,SG1,,,,,,,Soll [4],[4] Wenn Vorgängerversion vorhanden + 30,Vorgängerversion,SG1,RFF,,00007,,,,Muss, + 31,Vorgängerversion,SG1,RFF,1153,00007,ACW,,Referenznummer einervorangegangenenNachricht,X, + 32,Vorgängerversion,SG1,RFF,1056,00007,,,Versionsnummer,X [908],[908] Format: Mögliche Werte: 1 bis n + 33,MP-ID Absender,SG2,,,,,,,Muss, + 34,MP-ID Absender,SG2,NAD,,00008,,,,Muss, + 35,MP-ID Absender,SG2,NAD,3035,00008,MS,,Dokumenten-/Nachrichtenausstellerbzw. -absender,X, + 36,MP-ID Absender,SG2,NAD,3039,00008,,,MP-ID,X [1],[1] Nur MP-ID aus Sparte Strom + 37,MP-ID Absender,SG2,NAD,3055,00008,9,,GS1,X, + 38,MP-ID Absender,SG2,NAD,3055,,293,,"DE, BDEW",X, + 39,Ansprechpartner,SG3,,,,,,,Kann, + 40,Ansprechpartner,SG3,CTA,,00009,,,,Muss, + 41,Ansprechpartner,SG3,CTA,3139,00009,IC,,Informationskontakt,X, + 42,Ansprechpartner,SG3,CTA,3412,00009,,,Name vom Ansprechpartner,X, + 43,Kommunikationsverbindung,SG3,COM,,00010,,,,Muss, + 44,Kommunikationsverbindung,SG3,COM,3148,00010,,,Nummer / Adresse,X (([939][6])∨ ([940][7]))∧ [502],"[6] wenn im DE3155 im demselben COM der Code EM vorhanden ist + [7] wenn im DE3155 im demselben COM der Code TE / FX / AJ / AL vorhanden ist + [502] Hinweis: Es darf nur eine Information im DE3148 übermittelt werden + [939] Format: Die Zeichenkette muss die Zeichen @ und . enthalten + [940] Format: Die Zeichenkette muss mit dem Zeichen + beginnen und danach dürfen nur noch Ziffern folgen" + 45,Kommunikationsverbindung,SG3,COM,3155,00010,EM,,Elektronische Post,X [1P0..1], + 46,Kommunikationsverbindung,SG3,COM,3155,,FX,,Telefax,X [1P0..1], + 47,Kommunikationsverbindung,SG3,COM,3155,,TE,,Telefon,X [1P0..1], + 48,Kommunikationsverbindung,SG3,COM,3155,,AJ,,weiteres Telefon,X [1P0..1], + 49,Kommunikationsverbindung,SG3,COM,3155,,AL,,Handy,X [1P0..1], + 50,MP-ID Empfänger,SG2,,,,,,,Muss, + 51,MP-ID Empfänger,SG2,NAD,,00011,,,,Muss, + 52,MP-ID Empfänger,SG2,NAD,3035,00011,MR,,Nachrichtenempfänger,X, + 53,MP-ID Empfänger,SG2,NAD,3039,00011,,,MP-ID,X [1],[1] Nur MP-ID aus Sparte Strom + 54,MP-ID Empfänger,SG2,NAD,3055,00011,9,,GS1,X, + 55,MP-ID Empfänger,SG2,NAD,3055,,293,,"DE, BDEW",X, + 56,Abschnitts-Kontrollsegment,,UNS,,00012,,,,Muss, + 57,Abschnitts-Kontrollsegment,,UNS,0081,00012,D,,Trennung von Kopf- undPositionsteil,X, + 58,Name und Adresse des Unternehmens,SG4,,,,,,,Muss [10],[10] Wenn BGM DE1373 = 11 (Dokument nicht verfügbar) nicht vorhanden + 59,Name und Adresse des Unternehmens,SG4,NAD,,00013,,,,Muss, + 60,Name und Adresse des Unternehmens,SG4,NAD,3035,00013,SU,,Lieferant,, + 61,Name und Adresse des Unternehmens,SG4,NAD,3035,,DDM,,Netzbetreiber,, + 62,Name und Adresse des Unternehmens,SG4,NAD,3035,,DEB,,Messstellenbetreiber,X, + 63,Name und Adresse des Unternehmens,SG4,NAD,3036,00013,,,Name,X [506],"[506] Hinweis: Das Datenelement ist so zu füllen, dass sein Inhalt den Vorgaben des USt.- Gesetzes genügt, so dass der Empfänger diese Daten in einer INVOIC nutzen kann." + 64,Name und Adresse des Unternehmens,SG4,NAD,3045,00013,Z02,,Struktur derFirmenbezeichnung,X, + 65,Name und Adresse des Unternehmens,SG4,NAD,3042,00013,,,Straße und Hausnummer oderPostfach,X [506],"[506] Hinweis: Das Datenelement ist so zu füllen, dass sein Inhalt den Vorgaben des USt.- Gesetzes genügt, so dass der Empfänger diese Daten in einer INVOIC nutzen kann." + 66,Name und Adresse des Unternehmens,SG4,NAD,3164,00013,,,Ort,X [506],"[506] Hinweis: Das Datenelement ist so zu füllen, dass sein Inhalt den Vorgaben des USt.- Gesetzes genügt, so dass der Empfänger diese Daten in einer INVOIC nutzen kann." + 67,Name und Adresse des Unternehmens,SG4,NAD,3251,00013,,,Postleitzahl,M [2] ∧[506]S [3] ∧ [506],"[2] Wenn der Code im DE3207 in der ""EDI@Energy Codeliste der europäischen Ländercodes"" in der Spalte ""PLZ vorhanden""" + 68,Name und Adresse des Unternehmens,SG4,NAD,3207,00013,,,"Ländername, Code",X [506],"[506] Hinweis: Das Datenelement ist so zu füllen, dass sein Inhalt den Vorgaben des USt.- Gesetzes genügt, so dass der Empfänger diese Daten in einer INVOIC nutzen kann." + 69,Bankverbindung,SG4,FII,,00014,,,,Muss, + 70,Bankverbindung,SG4,FII,3035,00014,BK,,Kreditinstitut,X, + 71,Bankverbindung,SG4,FII,3194,00014,IBAN,,,X, + 72,Bankverbindung,SG4,FII,3192,00014,,,Name des Kontoinhabers,X, + 73,Bankverbindung,SG4,FII,3192,00014,,,Name des Kontoinhabers,K, + 74,Bankverbindung,SG4,FII,3433,00014,BIC,,,X, + 75,Bankverbindung,SG4,FII,3432,00014,,,Name des Kredinstituts,X, + 76,Internetseite (URL),SG4,FTX,,00015,,,,Muss, + 77,Internetseite (URL),SG4,FTX,4451,00015,Z13,,Internetseite,X, + 78,Internetseite (URL),SG4,FTX,4440,00015,,,Internetseite,X, + 79,Gericht und Handelsregister-Nummer,SG4,FTX,,00016,,,,Soll [3],[3] wenn vorhanden + 80,Gericht und Handelsregister-Nummer,SG4,FTX,4451,00016,Z15,,Gericht undHandelsregister-Nummer,X, + 81,Gericht und Handelsregister-Nummer,SG4,FTX,4440,00016,,,Gericht,X, + 82,Gericht und Handelsregister-Nummer,SG4,FTX,4440,00016,,,Handelsregister-Nummer,X, + 83,"Steuernummer, Umsatzsteuernummer",SG6,,,,,,,Muss [504],[504] Hinweis: Es ist mindestens die + 84,"Steuernummer, Umsatzsteuernummer",SG6,RFF,,00017,,,,Muss, + 85,"Steuernummer, Umsatzsteuernummer",SG6,RFF,1153,00017,VA,,Umsatzsteuernummer,X [2P0..1] ⊻[3P1..1], + 86,"Steuernummer, Umsatzsteuernummer",SG6,RFF,1153,,FC,,Steuernummer,X [2P0..1], + 87,"Steuernummer, Umsatzsteuernummer",SG6,RFF,1154,00017,,,"Referenz, Identifikation",X, + 88,Faxnummer,SG6,RFF,,00018,,,,Kann, + 89,Faxnummer,SG6,RFF,1153,00018,Z25,,Faxnummer,X, + 90,Faxnummer,SG6,RFF,1154,00018,,,Faxnummer,X [940],[940] Format: Die Zeichenkette muss mit dem Zeichen + beginnen und danach dürfen nur noch Ziffern folgen + 91,Erreichbarkeit an Werktagen,SG12,,,,,,,Muss, + 92,Erreichbarkeit an Werktagen,SG12,CCI,,00019,,,,Muss, + 93,Erreichbarkeit an Werktagen,SG12,CCI,7059,00019,Z40,,Erreichbarkeit desUnternehmens,X, + 94,Erreichbarkeit,SG12,DTM,,00020,,,,Muss, + 95,Erreichbarkeit,SG12,DTM,2005,00020,Z36,,Verfügbarkeit Montag,X [1P1..1], + 96,Erreichbarkeit,SG12,DTM,2005,,Z37,,Verfügbarkeit Dienstag,X [1P1..1], + 97,Erreichbarkeit,SG12,DTM,2005,,Z38,,Verfügbarkeit Mittwoch,X [1P1..1], + 98,Erreichbarkeit,SG12,DTM,2005,,Z39,,VerfügbarkeitDonnerstag,X [1P1..1], + 99,Erreichbarkeit,SG12,DTM,2005,,Z40,,Verfügbarkeit Freitag,X [1P1..1], + 100,Erreichbarkeit,SG12,DTM,2005,,Z41,,Mittagspause (=Ausschluss derVerfügbarkeit),X [1P0..1], + 101,Erreichbarkeit,SG12,DTM,2380,00020,,,"Datum oder Uhrzeit oderZeitspanne, Wert",X [503],[503] Hinweis: Angabe erfolgt in gesetzlicher deutscher Zeit + 102,Erreichbarkeit,SG12,DTM,2379,00020,501,,HHMMHHMM,X, + 103,Name und Anschrift Ansprechpartner Übertragungsweg / Datenaustausch,SG4,,,,,,,Muss [10],[10] Wenn BGM DE1373 = 11 (Dokument nicht verfügbar) nicht + 104,Name und Anschrift Ansprechpartner Übertragungsweg / Datenaustausch,SG4,NAD,,00021,,,,Muss, + 105,Name und Anschrift Ansprechpartner Übertragungsweg / Datenaustausch,SG4,NAD,3035,00021,Z10,,AnsprechpartnerÜbertragungsweg /Datenaustausch,X, + 106,Name und Anschrift Ansprechpartner Übertragungsweg / Datenaustausch,SG4,NAD,3036,00021,,,Name,X [500],[500] Hinweis: Es kann der Firmenname eines Dienstleisters oder die identische Firmenbezeichnung aus SG4 NAD+SU / DDM / DEB / Z31 / Z34 / Z35 / Z36 eingetragen werden. + 107,Name und Anschrift Ansprechpartner Übertragungsweg / Datenaustausch,SG4,NAD,3045,00021,Z02,,Struktur derFirmenbezeichnung,X, + 108,Name und Anschrift Ansprechpartner Übertragungsweg / Datenaustausch,SG4,NAD,3042,00021,,,Straße und Hausnummer oderPostfach,X, + 109,Name und Anschrift Ansprechpartner Übertragungsweg / Datenaustausch,SG4,NAD,3164,00021,,,Ort,X, + 110,Name und Anschrift Ansprechpartner Übertragungsweg / Datenaustausch,SG4,NAD,3251,00021,,,Postleitzahl,M [2]S [3],"[2] Wenn der Code im DE3207 in der ""EDI@Energy Codeliste der europäischen Ländercodes"" in der Spalte ""PLZ vorhanden"" ein ""X"" enthält + [3] wenn vorhanden" + 111,Name und Anschrift Ansprechpartner Übertragungsweg / Datenaustausch,SG4,NAD,3207,00021,,,"Ländername, Code",X, + 112,Ansprechpartner,SG7,,,,,,,Muss, + 113,Ansprechpartner,SG7,CTA,,00022,,,,Muss, + 114,Ansprechpartner,SG7,CTA,3139,00022,IC,,Informationskontakt,X, + 115,Ansprechpartner,SG7,CTA,3412,00022,,,Name der organisatorischenEinheit,X [501],"[501] Hinweis: Es darf kein Name einer natürlichen Person übermittelt werden, stattdessen ist die organisatorische Einheit im Unternehmen zu nennen." + 116,Kommunikationsverbindung,SG7,COM,,00023,,,,Muss, + 117,Kommunikationsverbindung,SG7,COM,3148,00023,,,Nummer / Adresse,X (([939][6])∨ ([940][8]))∧ [502],"[6] wenn im DE3155 im demselben COM der Code EM vorhanden ist + [8] wenn im DE3155 im" + 118,Kommunikationsverbindung,SG7,COM,3155,00023,EM,,Elektronische Post,X [1P1..1], + 119,Kommunikationsverbindung,SG7,COM,3155,,TE,,Telefon,X [1P1..1], + 120,Kommunikationsverbindung,SG7,COM,3155,,FX,,Telefax,X [1P0..1], + 121,Name und Anschrift Ansprechpartner Rahmenverträge,SG4,,,,,,,Muss [10] ∧[21],"[10] Wenn BGM DE1373 = 11 (Dokument nicht verfügbar) nicht vorhanden + [17] Wenn MP-ID in SG2 NAD+MR (Nachrichtenempfänger) in der Rolle LF/NB/MSB + [18] Wenn MP-ID in SG2 NAD+MR (Nachrichtenempfänger) in der Rolle LF/MSB + [21] Wenn MP-ID in SG2 NAD+MR (Nachrichtenempfänger) in der Rolle LF/NB/ESA" + 122,Name und Anschrift Ansprechpartner Rahmenverträge,SG4,NAD,,00024,,,,Muss, + 123,Name und Anschrift Ansprechpartner Rahmenverträge,SG4,NAD,3035,00024,Z11,,AnsprechpartnerRahmenverträge,X, + 124,Name und Anschrift Ansprechpartner Rahmenverträge,SG4,NAD,3036,00024,,,Name,X [500],[500] Hinweis: Es kann der Firmenname eines Dienstleisters oder die + 125,Name und Anschrift Ansprechpartner Rahmenverträge,SG4,NAD,3045,00024,Z02,,Struktur derFirmenbezeichnung,X, + 126,Name und Anschrift Ansprechpartner Rahmenverträge,SG4,NAD,3042,00024,,,Straße und Hausnummer oderPostfach,X, + 127,Name und Anschrift Ansprechpartner Rahmenverträge,SG4,NAD,3164,00024,,,Ort,X, + 128,Name und Anschrift Ansprechpartner Rahmenverträge,SG4,NAD,3251,00024,,,Postleitzahl,M [2]S [3],"[2] Wenn der Code im DE3207 in der ""EDI@Energy Codeliste der europäischen Ländercodes"" in der Spalte ""PLZ vorhanden"" ein ""X"" enthält + [3] wenn vorhanden" + 129,Name und Anschrift Ansprechpartner Rahmenverträge,SG4,NAD,3207,00024,,,"Ländername, Code",X, + 130,Ansprechpartner,SG7,,,,,,,Muss, + 131,Ansprechpartner,SG7,CTA,,00025,,,,Muss, + 132,Ansprechpartner,SG7,CTA,3139,00025,IC,,Informationskontakt,X, + 133,Ansprechpartner,SG7,CTA,3412,00025,,,Name der organisatorischenEinheit,X [501],"[501] Hinweis: Es darf kein Name einer natürlichen Person übermittelt werden, stattdessen ist die organisatorische Einheit im Unternehmen zu nennen." + 134,Kommunikationsverbindung,SG7,COM,,00026,,,,Muss, + 135,Kommunikationsverbindung,SG7,COM,3148,00026,,,Nummer / Adresse,X (([939][6])∨ ([940][8]))∧ [502],"[6] wenn im DE3155 im demselben COM der Code EM vorhanden ist + [8] wenn im DE3155 im demselben COM der Code TE / FX vorhanden ist + [502] Hinweis: Es darf nur eine Information im DE3148 übermittelt werden" + 136,Kommunikationsverbindung,SG7,COM,3155,00026,EM,,Elektronische Post,X [1P1..1], + 137,Kommunikationsverbindung,SG7,COM,3155,,TE,,Telefon,X [1P1..1], + 138,Kommunikationsverbindung,SG7,COM,3155,,FX,,Telefax,X [1P0..1], + 139,Name und Anschrift Ansprechpartner Kündigungsprozess,SG4,,,,,,,Muss [10] ∧[22],"[5] Wenn MP-ID in SG2 NAD+MR (Nachrichtenempfänger) in der Rolle LF + [10] Wenn BGM DE1373 = 11 (Dokument nicht verfügbar) nicht vorhanden + [22] Wenn MP-ID in SG2 NAD+MR (Nachrichtenempfänger) in der Rolle MSB" + 140,Name und Anschrift Ansprechpartner Kündigungsprozess,SG4,NAD,,00027,,,,Muss, + 141,Name und Anschrift Ansprechpartner Kündigungsprozess,SG4,NAD,3035,00027,Z12,,AnsprechpartnerKündigungsprozesse,X, + 142,Name und Anschrift Ansprechpartner Kündigungsprozess,SG4,NAD,3036,00027,,,Name,X [500],[500] Hinweis: Es kann der Firmenname eines Dienstleisters oder die identische Firmenbezeichnung aus SG4 NAD+SU / DDM / DEB / Z31 / Z34 / Z35 / Z36 eingetragen werden. + 143,Name und Anschrift Ansprechpartner Kündigungsprozess,SG4,NAD,3045,00027,Z02,,Struktur derFirmenbezeichnung,X, + 144,Name und Anschrift Ansprechpartner Kündigungsprozess,SG4,NAD,3042,00027,,,Straße und Hausnummer oderPostfach,X, + 145,Name und Anschrift Ansprechpartner Kündigungsprozess,SG4,NAD,3164,00027,,,Ort,X, + 146,Name und Anschrift Ansprechpartner Kündigungsprozess,SG4,NAD,3251,00027,,,Postleitzahl,M [2]S [3],[2] Wenn der Code im DE3207 in der + 147,Name und Anschrift Ansprechpartner Kündigungsprozess,SG4,NAD,3207,00027,,,"Ländername, Code",X, + 148,Ansprechpartner,SG7,,,,,,,Muss, + 149,Ansprechpartner,SG7,CTA,,00028,,,,Muss, + 150,Ansprechpartner,SG7,CTA,3139,00028,IC,,Informationskontakt,X, + 151,Ansprechpartner,SG7,CTA,3412,00028,,,Name der organisatorischenEinheit,X [501],"[501] Hinweis: Es darf kein Name einer natürlichen Person übermittelt werden, stattdessen ist die organisatorische Einheit im Unternehmen zu nennen." + 152,Kommunikationsverbindung,SG7,COM,,00029,,,,Muss, + 153,Kommunikationsverbindung,SG7,COM,3148,00029,,,Nummer / Adresse,X (([939][6])∨ ([940][8]))∧ [502],"[6] wenn im DE3155 im demselben COM der Code EM vorhanden ist + [8] wenn im DE3155 im demselben COM der Code TE / FX vorhanden ist + [502] Hinweis: Es darf nur eine Information im DE3148 übermittelt werden + [939] Format: Die Zeichenkette muss die Zeichen @ und . enthalten + [940] Format: Die Zeichenkette muss mit dem Zeichen + beginnen und danach dürfen nur noch Ziffern folgen" + 154,Kommunikationsverbindung,SG7,COM,3155,00029,EM,,Elektronische Post,X [1P1..1], + 155,Kommunikationsverbindung,SG7,COM,3155,,TE,,Telefon,X [1P1..1], + 156,Name und Anschrift Ansprechpartner Wechselprozesse,SG4,,,,,,,Muss [10] ∧[17],"[10] Wenn BGM DE1373 = 11 (Dokument nicht verfügbar) nicht vorhanden + [17] Wenn MP-ID in SG2 NAD+MR (Nachrichtenempfänger) in der Rolle LF/NB/MSB" + 157,Name und Anschrift Ansprechpartner Wechselprozesse,SG4,NAD,,00030,,,,Muss, + 158,Name und Anschrift Ansprechpartner Wechselprozesse,SG4,NAD,3035,00030,Z13,,AnsprechpartnerWechselprozesse,X, + 159,Name und Anschrift Ansprechpartner Wechselprozesse,SG4,NAD,3036,00030,,,Name,X [500],[500] Hinweis: Es kann der Firmenname eines Dienstleisters oder die identische Firmenbezeichnung aus SG4 NAD+SU / DDM / DEB / Z31 / Z34 / Z35 / Z36 eingetragen werden. + 160,Name und Anschrift Ansprechpartner Wechselprozesse,SG4,NAD,3045,00030,Z02,,Struktur derFirmenbezeichnung,X, + 161,Name und Anschrift Ansprechpartner Wechselprozesse,SG4,NAD,3042,00030,,,Straße und Hausnummer oderPostfach,X, + 162,Name und Anschrift Ansprechpartner Wechselprozesse,SG4,NAD,3164,00030,,,Ort,X, + 163,Name und Anschrift Ansprechpartner Wechselprozesse,SG4,NAD,3251,00030,,,Postleitzahl,M [2]S [3],"[2] Wenn der Code im DE3207 in der ""EDI@Energy Codeliste der europäischen Ländercodes"" in der Spalte ""PLZ vorhanden"" ein ""X"" enthält + [3] wenn vorhanden" + 164,Name und Anschrift Ansprechpartner Wechselprozesse,SG4,NAD,3207,00030,,,"Ländername, Code",X, + 165,Ansprechpartner,SG7,,,,,,,Muss, + 166,Ansprechpartner,SG7,CTA,,00031,,,,Muss, + 167,Ansprechpartner,SG7,CTA,3139,00031,IC,,Informationskontakt,X, + 168,Ansprechpartner,SG7,CTA,3412,00031,,,Name der organisatorischenEinheit,X [501],"[501] Hinweis: Es darf kein Name einer natürlichen Person übermittelt werden, stattdessen ist die" + 169,Kommunikationsverbindung,SG7,COM,,00032,,,,Muss, + 170,Kommunikationsverbindung,SG7,COM,3148,00032,,,Nummer / Adresse,X (([939][6])∨ ([940][8]))∧ [502],"[6] wenn im DE3155 im demselben COM der Code EM vorhanden ist + [8] wenn im DE3155 im demselben COM der Code TE / FX vorhanden ist + [502] Hinweis: Es darf nur eine Information im DE3148 übermittelt werden + [939] Format: Die Zeichenkette muss die Zeichen @ und . enthalten + [940] Format: Die Zeichenkette muss mit dem Zeichen + beginnen und danach dürfen nur noch Ziffern folgen" + 171,Kommunikationsverbindung,SG7,COM,3155,00032,EM,,Elektronische Post,X [1P1..1], + 172,Kommunikationsverbindung,SG7,COM,3155,,TE,,Telefon,X [1P1..1], + 173,Kommunikationsverbindung,SG7,COM,3155,,FX,,Telefax,X [1P0..1], + 174,Name und Anschrift Ansprechpartner Stammdatenprozesse,SG4,,,,,,,Muss [10] ∧[19],"[10] Wenn BGM DE1373 = 11 (Dokument nicht verfügbar) nicht vorhanden + [19] Wenn MP-ID in SG2 NAD+MR (Nachrichtenempfänger) in der Rolle LF/MSB/ NB/ÜNB" + 175,Name und Anschrift Ansprechpartner Stammdatenprozesse,SG4,NAD,,00033,,,,Muss, + 176,Name und Anschrift Ansprechpartner Stammdatenprozesse,SG4,NAD,3035,00033,Z14,,AnsprechpartnerStammdatenprozesse,X, + 177,Name und Anschrift Ansprechpartner Stammdatenprozesse,SG4,NAD,3036,00033,,,Name,X [500],[500] Hinweis: Es kann der Firmenname eines Dienstleisters oder die identische Firmenbezeichnung aus SG4 NAD+SU / DDM / DEB / Z31 / Z34 / Z35 / Z36 eingetragen werden. + 178,Name und Anschrift Ansprechpartner Stammdatenprozesse,SG4,NAD,3045,00033,Z02,,Struktur derFirmenbezeichnung,X, + 179,Name und Anschrift Ansprechpartner Stammdatenprozesse,SG4,NAD,3042,00033,,,Straße und Hausnummer oderPostfach,X, + 180,Name und Anschrift Ansprechpartner Stammdatenprozesse,SG4,NAD,3164,00033,,,Ort,X, + 181,Name und Anschrift Ansprechpartner Stammdatenprozesse,SG4,NAD,3251,00033,,,Postleitzahl,M [2]S [3],"[2] Wenn der Code im DE3207 in der ""EDI@Energy Codeliste der europäischen Ländercodes"" in der Spalte ""PLZ vorhanden"" ein ""X"" enthält + [3] wenn vorhanden" + 182,Name und Anschrift Ansprechpartner Stammdatenprozesse,SG4,NAD,3207,00033,,,"Ländername, Code",X, + 183,Ansprechpartner,SG7,,,,,,,Muss, + 184,Ansprechpartner,SG7,CTA,,00034,,,,Muss, + 185,Ansprechpartner,SG7,CTA,3139,00034,IC,,Informationskontakt,X, + 186,Ansprechpartner,SG7,CTA,3412,00034,,,Name der organisatorischenEinheit,X [501],"[501] Hinweis: Es darf kein Name einer natürlichen Person übermittelt werden, stattdessen ist die organisatorische Einheit im Unternehmen zu nennen." + 187,Kommunikationsverbindung,SG7,COM,,00035,,,,Muss, + 188,Kommunikationsverbindung,SG7,COM,3148,00035,,,Nummer / Adresse,X (([939][6])∨ ([940][8]))∧ [502],"[6] wenn im DE3155 im demselben COM der Code EM vorhanden ist + [8] wenn im DE3155 im demselben COM der Code TE / FX vorhanden ist + [502] Hinweis: Es darf" + 189,Kommunikationsverbindung,SG7,COM,3155,00035,EM,,Elektronische Post,X [1P1..1], + 190,Kommunikationsverbindung,SG7,COM,3155,,TE,,Telefon,X [1P1..1], + 191,Kommunikationsverbindung,SG7,COM,3155,,FX,,Telefax,X [1P0..1], + 192,Name und Anschrift Ansprechpartner Einspeiseprozesse,SG4,,,,,,,Muss [10] ∧[23],"[10] Wenn BGM DE1373 = 11 (Dokument nicht verfügbar) nicht vorhanden + [17] Wenn MP-ID in SG2 NAD+MR (Nachrichtenempfänger) in der Rolle LF/NB/MSB + [18] Wenn MP-ID in SG2 NAD+MR (Nachrichtenempfänger) in der Rolle LF/MSB + [23] Wenn MP-ID in SG2 NAD+MR (Nachrichtenempfänger) in der Rolle NB/ÜNB" + 193,Name und Anschrift Ansprechpartner Einspeiseprozesse,SG4,NAD,,00036,,,,Muss, + 194,Name und Anschrift Ansprechpartner Einspeiseprozesse,SG4,NAD,3035,00036,Z16,,AnsprechpartnerEinspeiseprozesse,X, + 195,Name und Anschrift Ansprechpartner Einspeiseprozesse,SG4,NAD,3036,00036,,,Name,X [500],[500] Hinweis: Es kann der Firmenname eines Dienstleisters oder die identische Firmenbezeichnung aus SG4 NAD+SU / DDM / DEB / Z31 / Z34 / Z35 / Z36 eingetragen werden. + 196,Name und Anschrift Ansprechpartner Einspeiseprozesse,SG4,NAD,3045,00036,Z02,,Struktur derFirmenbezeichnung,X, + 197,Name und Anschrift Ansprechpartner Einspeiseprozesse,SG4,NAD,3042,00036,,,Straße und Hausnummer oderPostfach,X, + 198,Name und Anschrift Ansprechpartner Einspeiseprozesse,SG4,NAD,3164,00036,,,Ort,X, + 199,Name und Anschrift Ansprechpartner Einspeiseprozesse,SG4,NAD,3251,00036,,,Postleitzahl,M [2]S [3],"[2] Wenn der Code im DE3207 in der ""EDI@Energy Codeliste der europäischen Ländercodes"" in der Spalte ""PLZ vorhanden"" ein ""X"" enthält + [3] wenn vorhanden" + 200,Name und Anschrift Ansprechpartner Einspeiseprozesse,SG4,NAD,3207,00036,,,"Ländername, Code",X, + 201,Ansprechpartner,SG7,,,,,,,Muss, + 202,Ansprechpartner,SG7,CTA,,00037,,,,Muss, + 203,Ansprechpartner,SG7,CTA,3139,00037,IC,,Informationskontakt,X, + 204,Ansprechpartner,SG7,CTA,3412,00037,,,Name der organisatorischenEinheit,X [501],"[501] Hinweis: Es darf kein Name einer natürlichen Person übermittelt werden, stattdessen ist die organisatorische Einheit im Unternehmen zu nennen." + 205,Kommunikationsverbindung,SG7,COM,,00038,,,,Muss, + 206,Kommunikationsverbindung,SG7,COM,3148,00038,,,Nummer / Adresse,X (([939][6])∨ ([940][8]))∧ [502],"[6] wenn im DE3155 im demselben COM der Code EM vorhanden ist + [8] wenn im DE3155 im demselben COM der Code TE / FX vorhanden ist + [502] Hinweis: Es darf nur eine Information im DE3148 übermittelt werden + [939] Format: Die Zeichenkette muss die Zeichen @ und . enthalten " + 207,Kommunikationsverbindung,SG7,COM,3155,00038,EM,,Elektronische Post,X [1P1..1], + 208,Kommunikationsverbindung,SG7,COM,3155,,TE,,Telefon,X [1P1..1], + 209,Kommunikationsverbindung,SG7,COM,3155,,FX,,Telefax,X [1P0..1], + 210,Name und Anschrift Ansprechpartner Abrechnungsprozesse,SG4,,,,,,,Muss [10] ∧[24],"[10] Wenn BGM DE1373 = 11 (Dokument nicht verfügbar) nicht vorhanden + [17] Wenn MP-ID in SG2 NAD+MR (Nachrichtenempfänger) in der Rolle LF/NB/MSB + [18] Wenn MP-ID in SG2 NAD+MR (Nachrichtenempfänger) in der Rolle LF/MSB + [24] Wenn MP-ID in SG2 NAD+MR (Nachrichtenempfänger) in der Rolle NB/LF/ MSB/ESA" + 211,Name und Anschrift Ansprechpartner Abrechnungsprozesse,SG4,NAD,,00039,,,,Muss, + 212,Name und Anschrift Ansprechpartner Abrechnungsprozesse,SG4,NAD,3035,00039,Z17,,AnsprechpartnerAbrechnungsprozesse,X, + 213,Name und Anschrift Ansprechpartner Abrechnungsprozesse,SG4,NAD,3036,00039,,,Name,X [500],[500] Hinweis: Es kann der Firmenname eines Dienstleisters oder die identische Firmenbezeichnung aus SG4 NAD+SU / DDM / DEB / Z31 / Z34 / Z35 / Z36 eingetragen werden. + 214,Name und Anschrift Ansprechpartner Abrechnungsprozesse,SG4,NAD,3045,00039,Z02,,Struktur derFirmenbezeichnung,X, + 215,Name und Anschrift Ansprechpartner Abrechnungsprozesse,SG4,NAD,3042,00039,,,Straße und Hausnummer oderPostfach,X, + 216,Name und Anschrift Ansprechpartner Abrechnungsprozesse,SG4,NAD,3164,00039,,,Ort,X, + 217,Name und Anschrift Ansprechpartner Abrechnungsprozesse,SG4,NAD,3251,00039,,,Postleitzahl,M [2]S [3],[2] Wenn der Code im DE3207 in der + 218,Name und Anschrift Ansprechpartner Abrechnungsprozesse,SG4,NAD,3207,00039,,,"Ländername, Code",X, + 219,Ansprechpartner,SG7,,,,,,,Muss, + 220,Ansprechpartner,SG7,CTA,,00040,,,,Muss, + 221,Ansprechpartner,SG7,CTA,3139,00040,IC,,Informationskontakt,X, + 222,Ansprechpartner,SG7,CTA,3412,00040,,,Name der organisatorischenEinheit,X [501],"[501] Hinweis: Es darf kein Name einer natürlichen Person übermittelt werden, stattdessen ist die organisatorische Einheit im Unternehmen zu nennen." + 223,Kommunikationsverbindung,SG7,COM,,00041,,,,Muss, + 224,Kommunikationsverbindung,SG7,COM,3148,00041,,,Nummer / Adresse,X (([939][6])∨ ([940][8]))∧ [502],"[6] wenn im DE3155 im demselben COM der Code EM vorhanden ist + [8] wenn im DE3155 im demselben COM der Code TE / FX vorhanden ist + [502] Hinweis: Es darf nur eine Information im DE3148 übermittelt werden + [939] Format: Die Zeichenkette muss die Zeichen @ und . enthalten + [940] Format: Die Zeichenkette muss mit dem Zeichen + beginnen und danach dürfen nur noch Ziffern folgen" + 225,Kommunikationsverbindung,SG7,COM,3155,00041,EM,,Elektronische Post,X [1P1..1], + 226,Kommunikationsverbindung,SG7,COM,3155,,TE,,Telefon,X [1P1..1], + 227,Name und Anschrift Ansprechpartner MMMA- Prozesse,SG4,,,,,,,,"[10] Wenn BGM DE1373 = 11 (Dokument nicht verfügbar) nicht vorhanden + [17] Wenn MP-ID in SG2 NAD+MR (Nachrichtenempfänger) in der Rolle LF/NB/MSB + [20] Wenn MP-ID in SG2 NAD+MR (Nachrichtenempfänger) in der Rolle LF/MSB/ÜNB" + 228,Name und Anschrift Ansprechpartner MMMA- Prozesse,SG4,NAD,,00042,,,,, + 229,Name und Anschrift Ansprechpartner MMMA- Prozesse,SG4,NAD,3035,00042,Z18,,AnsprechpartnerMMMA-Prozesse,, + 230,Name und Anschrift Ansprechpartner MMMA- Prozesse,SG4,NAD,3036,00042,,,Name,,[500] Hinweis: Es kann der Firmenname eines Dienstleisters oder die identische Firmenbezeichnung aus SG4 NAD+SU / DDM / DEB / Z31 / Z34 / Z35 / Z36 eingetragen werden. + 231,Name und Anschrift Ansprechpartner MMMA- Prozesse,SG4,NAD,3045,00042,Z02,,Struktur derFirmenbezeichnung,, + 232,Name und Anschrift Ansprechpartner MMMA- Prozesse,SG4,NAD,3042,00042,,,Straße und Hausnummer oderPostfach,, + 233,Name und Anschrift Ansprechpartner MMMA- Prozesse,SG4,NAD,3164,00042,,,Ort,, + 234,Name und Anschrift Ansprechpartner MMMA- Prozesse,SG4,NAD,3251,00042,,,Postleitzahl,,"[2] Wenn der Code im DE3207 in der ""EDI@Energy Codeliste der europäischen Ländercodes"" in der Spalte ""PLZ vorhanden"" ein ""X"" enthält + [3] wenn vorhanden" + 235,Name und Anschrift Ansprechpartner MMMA- Prozesse,SG4,NAD,3207,00042,,,"Ländername, Code",, + 236,Ansprechpartner,SG7,,,,,,,, + 237,Ansprechpartner,SG7,CTA,,00043,,,,, + 238,Ansprechpartner,SG7,CTA,3139,00043,IC,,Informationskontakt,, + 239,Ansprechpartner,SG7,CTA,3412,00043,,,Name der organisatorischenEinheit,,"[501] Hinweis: Es darf kein Name einer natürlichen Person übermittelt werden, stattdessen ist die organisatorische Einheit im Unternehmen zu nennen." + 240,Kommunikationsverbindung,SG7,COM,,00044,,,,, + 241,Kommunikationsverbindung,SG7,COM,3148,00044,,,Nummer / Adresse,,"[6] wenn im DE3155 im demselben COM der Code EM vorhanden ist + [8] wenn im DE3155 im demselben COM der Code TE / FX vorhanden ist + [502] Hinweis: Es darf nur eine Information im DE3148 übermittelt werden + [939] Format: Die Zeichenkette muss die Zeichen @ und . enthalten + [940] Format: Die Zeichenkette muss mit dem Zeichen + beginnen und danach dürfen nur noch Ziffern folgen" + 242,Kommunikationsverbindung,SG7,COM,3155,00044,EM,,Elektronische Post,, + 243,Kommunikationsverbindung,SG7,COM,3155,,TE,,Telefon,, + 244,Kommunikationsverbindung,SG7,COM,3155,,FX,,Telefax,, + 245,Name und Anschrift Bewegungsdaten,SG4,,,,,,,Muss [10],"[10] Wenn BGM DE1373 = 11 (Dokument nicht verfügbar) nicht vorhanden + [19] Wenn MP-ID in SG2 NAD+MR (Nachrichtenempfänger) in der Rolle LF/MSB/" + 246,Name und Anschrift Bewegungsdaten,SG4,NAD,,00045,,,,Muss, + 247,Name und Anschrift Bewegungsdaten,SG4,NAD,3035,00045,Z19,,AnsprechpartnerBewegungsdaten,X, + 248,Name und Anschrift Bewegungsdaten,SG4,NAD,3036,00045,,,Name,X [500],[500] Hinweis: Es kann der Firmenname eines Dienstleisters oder die identische Firmenbezeichnung aus SG4 NAD+SU / DDM / DEB / Z31 / Z34 / Z35 / Z36 eingetragen werden. + 249,Name und Anschrift Bewegungsdaten,SG4,NAD,3045,00045,Z02,,Struktur derFirmenbezeichnung,X, + 250,Name und Anschrift Bewegungsdaten,SG4,NAD,3042,00045,,,Straße und Hausnummer oderPostfach,X, + 251,Name und Anschrift Bewegungsdaten,SG4,NAD,3164,00045,,,Ort,X, + 252,Name und Anschrift Bewegungsdaten,SG4,NAD,3251,00045,,,Postleitzahl,M [2]S [3],"[2] Wenn der Code im DE3207 in der ""EDI@Energy Codeliste der europäischen Ländercodes"" in der Spalte ""PLZ vorhanden"" ein ""X"" enthält + [3] wenn vorhanden" + 253,Name und Anschrift Bewegungsdaten,SG4,NAD,3207,00045,,,"Ländername, Code",X, + 254,Ansprechpartner,SG7,,,,,,,Muss, + 255,Ansprechpartner,SG7,CTA,,00046,,,,Muss, + 256,Ansprechpartner,SG7,CTA,3139,00046,IC,,Informationskontakt,X, + 257,Ansprechpartner,SG7,CTA,3412,00046,,,Name der organisatorischenEinheit,X [501],"[501] Hinweis: Es darf kein Name einer natürlichen Person übermittelt werden, stattdessen ist die organisatorische Einheit im Unternehmen zu nennen." + 258,Kommunikationsverbindung,SG7,COM,,00047,,,,Muss, + 259,Kommunikationsverbindung,SG7,COM,3148,00047,,,Nummer / Adresse,X (([939][6])∨ ([940][8]))∧ [502],"[6] wenn im DE3155 im demselben COM der Code EM vorhanden ist + [8] wenn im DE3155 im demselben COM der" + 260,Kommunikationsverbindung,SG7,COM,3155,00047,EM,,Elektronische Post,X [1P1..1], + 261,Kommunikationsverbindung,SG7,COM,3155,,TE,,Telefon,X [1P1..1], + 262,Kommunikationsverbindung,SG7,COM,3155,,FX,,Telefax,X [1P0..1], + 263,Name und Anschrift Ansprechpartner Prozesse zur Unterbrechung und Wiederherstellung der Anschlussnutzung,SG4,,,,,,,,"[10] Wenn BGM DE1373 = 11 (Dokument nicht verfügbar) nicht vorhanden + [17] Wenn MP-ID in SG2 NAD+MR (Nachrichtenempfänger) in der Rolle LF/NB/MSB + [20] Wenn MP-ID in SG2 NAD+MR (Nachrichtenempfänger) in der Rolle LF/MSB/ÜNB" + 264,Name und Anschrift Ansprechpartner Prozesse zur Unterbrechung und Wiederherstellung der Anschlussnutzung,SG4,NAD,,00048,,,,, + 265,Name und Anschrift Ansprechpartner Prozesse zur Unterbrechung und Wiederherstellung der Anschlussnutzung,SG4,NAD,3035,00048,Z20,,AnsprechpartnerSperr-/Entsperrprozesse,, + 266,Name und Anschrift Ansprechpartner Prozesse zur Unterbrechung und Wiederherstellung der Anschlussnutzung,SG4,NAD,3036,00048,,,Name,,[500] Hinweis: Es kann der Firmenname eines Dienstleisters oder die identische Firmenbezeichnung aus SG4 NAD+SU / DDM / DEB / Z31 / Z34 / Z35 / + 267,Name und Anschrift Ansprechpartner Prozesse zur Unterbrechung und Wiederherstellung der Anschlussnutzung,SG4,NAD,3045,00048,Z02,,Struktur derFirmenbezeichnung,, + 268,Name und Anschrift Ansprechpartner Prozesse zur Unterbrechung und Wiederherstellung der Anschlussnutzung,SG4,NAD,3042,00048,,,Straße und Hausnummer oderPostfach,, + 269,Name und Anschrift Ansprechpartner Prozesse zur Unterbrechung und Wiederherstellung der Anschlussnutzung,SG4,NAD,3164,00048,,,Ort,, + 270,Name und Anschrift Ansprechpartner Prozesse zur Unterbrechung und Wiederherstellung der Anschlussnutzung,SG4,NAD,3251,00048,,,Postleitzahl,,"[2] Wenn der Code im DE3207 in der ""EDI@Energy Codeliste der europäischen Ländercodes"" in der Spalte ""PLZ vorhanden"" ein ""X"" enthält + [3] wenn vorhanden" + 271,Name und Anschrift Ansprechpartner Prozesse zur Unterbrechung und Wiederherstellung der Anschlussnutzung,SG4,NAD,3207,00048,,,"Ländername, Code",, + 272,Ansprechpartner,SG7,,,,,,,, + 273,Ansprechpartner,SG7,CTA,,00049,,,,, + 274,Ansprechpartner,SG7,CTA,3139,00049,IC,,Informationskontakt,, + 275,Ansprechpartner,SG7,CTA,3412,00049,,,Name der organisatorischenEinheit,,"[501] Hinweis: Es darf kein Name einer natürlichen Person übermittelt werden, stattdessen ist die organisatorische Einheit im Unternehmen zu nennen." + 276,Kommunikationsverbindung,SG7,COM,,00050,,,,, + 277,Kommunikationsverbindung,SG7,COM,3148,00050,,,Nummer / Adresse,,"[6] wenn im DE3155 im demselben COM der Code EM vorhanden ist + [8] wenn im DE3155 im demselben COM der Code TE / FX vorhanden ist + [502] Hinweis: Es darf nur eine Information im DE3148 übermittelt werden + [939] Format: Die Zeichenkette muss die Zeichen @ und ." + 278,Kommunikationsverbindung,SG7,COM,3155,00050,EM,,Elektronische Post,, + 279,Kommunikationsverbindung,SG7,COM,3155,,TE,,Telefon,, + 280,Kommunikationsverbindung,SG7,COM,3155,,FX,,Telefax,, + 281,Name und Anschrift Ansprechpartner Bilanzierungsprozesse / Bilanzkreismanagement,SG4,,,,,,,,[10] Wenn BGM DE1373 = 11 (Dokument nicht verfügbar) nicht vorhanden + 282,Name und Anschrift Ansprechpartner Bilanzierungsprozesse / Bilanzkreismanagement,SG4,NAD,,00051,,,,, + 283,Name und Anschrift Ansprechpartner Bilanzierungsprozesse / Bilanzkreismanagement,SG4,NAD,3035,00051,Z21,,AnsprechpartnerBilanzierungsprozesse /Bilanzkreismanagement,, + 284,Name und Anschrift Ansprechpartner Bilanzierungsprozesse / Bilanzkreismanagement,SG4,NAD,3036,00051,,,Name,,[500] Hinweis: Es kann der Firmenname eines Dienstleisters oder die identische Firmenbezeichnung aus SG4 NAD+SU / DDM / DEB / Z31 / Z34 / Z35 / Z36 eingetragen werden. + 285,Name und Anschrift Ansprechpartner Bilanzierungsprozesse / Bilanzkreismanagement,SG4,NAD,3045,00051,Z02,,Struktur derFirmenbezeichnung,, + 286,Name und Anschrift Ansprechpartner Bilanzierungsprozesse / Bilanzkreismanagement,SG4,NAD,3042,00051,,,Straße und Hausnummer oderPostfach,, + 287,Name und Anschrift Ansprechpartner Bilanzierungsprozesse / Bilanzkreismanagement,SG4,NAD,3164,00051,,,Ort,, + 288,Name und Anschrift Ansprechpartner Bilanzierungsprozesse / Bilanzkreismanagement,SG4,NAD,3251,00051,,,Postleitzahl,,"[2] Wenn der Code im DE3207 in der ""EDI@Energy Codeliste der europäischen Ländercodes"" in der Spalte ""PLZ vorhanden"" ein ""X"" enthält + [3] wenn vorhanden" + 289,Name und Anschrift Ansprechpartner Bilanzierungsprozesse / Bilanzkreismanagement,SG4,NAD,3207,00051,,,"Ländername, Code",, + 290,Ansprechpartner,SG7,,,,,,,, + 291,Ansprechpartner,SG7,CTA,,00052,,,,, + 292,Ansprechpartner,SG7,CTA,3139,00052,IC,,Informationskontakt,, + 293,Ansprechpartner,SG7,CTA,3412,00052,,,Name der organisatorischenEinheit,,"[501] Hinweis: Es darf kein Name einer natürlichen Person übermittelt werden, stattdessen ist die organisatorische Einheit im Unternehmen zu nennen." + 294,Kommunikationsverbindung,SG7,COM,,00053,,,,, + 295,Kommunikationsverbindung,SG7,COM,3148,00053,,,Nummer / Adresse,,"[6] wenn im DE3155 im demselben COM der Code EM vorhanden ist + [8] wenn im DE3155 im demselben COM der Code TE / FX vorhanden ist + [502] Hinweis: Es darf nur eine Information im DE3148 übermittelt werden + [939] Format: Die Zeichenkette muss die Zeichen @ und . enthalten + [940] Format: Die Zeichenkette muss mit dem Zeichen + beginnen und danach dürfen nur noch Ziffern folgen" + 296,Kommunikationsverbindung,SG7,COM,3155,00053,EM,,Elektronische Post,, + 297,Kommunikationsverbindung,SG7,COM,3155,,TE,,Telefon,, + 298,Kommunikationsverbindung,SG7,COM,3155,,FX,,Telefax,, + 299,Name und Anschrift Ansprechpartner Technischer Netzanschluss für Neuanlagen und Anlagenumbau,SG4,,,,,,,,[10] Wenn BGM DE1373 = 11 (Dokument nicht verfügbar) nicht vorhanden + 300,Name und Anschrift Ansprechpartner Technischer Netzanschluss für Neuanlagen und Anlagenumbau,SG4,NAD,,00054,,,,, + 301,Name und Anschrift Ansprechpartner Technischer Netzanschluss für Neuanlagen und Anlagenumbau,SG4,NAD,3035,00054,Z33,,AnsprechpartnertechnischerNetzanschluss fürNeuanlagen undAnlagenumbau,, + 302,Name und Anschrift Ansprechpartner Technischer Netzanschluss für Neuanlagen und Anlagenumbau,SG4,NAD,3036,00054,,,Name,,[500] Hinweis: Es kann der Firmenname eines Dienstleisters oder die identische Firmenbezeichnung aus SG4 NAD+SU / DDM / DEB / Z31 / Z34 / Z35 / Z36 eingetragen werden. + 303,Name und Anschrift Ansprechpartner Technischer Netzanschluss für Neuanlagen und Anlagenumbau,SG4,NAD,3045,00054,Z02,,Struktur derFirmenbezeichnung,, + 304,Name und Anschrift Ansprechpartner Technischer Netzanschluss für Neuanlagen und Anlagenumbau,SG4,NAD,3042,00054,,,Straße und Hausnummer oderPostfach,, + 305,Name und Anschrift Ansprechpartner Technischer Netzanschluss für Neuanlagen und Anlagenumbau,SG4,NAD,3164,00054,,,Ort,, + 306,Name und Anschrift Ansprechpartner Technischer Netzanschluss für Neuanlagen und Anlagenumbau,SG4,NAD,3251,00054,,,Postleitzahl,,"[2] Wenn der Code im DE3207 in der ""EDI@Energy Codeliste der europäischen Ländercodes"" in der Spalte ""PLZ vorhanden"" ein ""X"" enthält + [3] wenn vorhanden" + 307,Name und Anschrift Ansprechpartner Technischer Netzanschluss für Neuanlagen und Anlagenumbau,SG4,NAD,3207,00054,,,"Ländername, Code",, + 308,Ansprechpartner,SG7,,,,,,,, + 309,Ansprechpartner,SG7,CTA,,00055,,,,, + 310,Ansprechpartner,SG7,CTA,3139,00055,IC,,Informationskontakt,, + 311,Ansprechpartner,SG7,CTA,3412,00055,,,Name der organisatorischenEinheit,,"[501] Hinweis: Es darf kein Name einer natürlichen Person übermittelt werden, stattdessen ist die organisatorische Einheit im Unternehmen zu nennen." + 312,Kommunikationsverbindung,SG7,COM,,00056,,,,, + 313,Kommunikationsverbindung,SG7,COM,3148,00056,,,Nummer / Adresse,,"[6] wenn im DE3155 im demselben COM der Code EM vorhanden ist + [8] wenn im DE3155 im demselben COM der Code TE / FX vorhanden ist + [502] Hinweis: Es darf nur eine Information im DE3148 übermittelt werden + [939] Format: Die Zeichenkette muss die Zeichen @ und . enthalten + [940] Format: Die Zeichenkette muss mit dem Zeichen + beginnen und danach dürfen nur noch Ziffern folgen" + 314,Kommunikationsverbindung,SG7,COM,3155,00056,EM,,Elektronische Post,, + 315,Kommunikationsverbindung,SG7,COM,3155,,TE,,Telefon,, + 316,Kommunikationsverbindung,SG7,COM,3155,,FX,,Telefax,, + 317,Nachrichten-Endesegment,,UNT,,00061,,,,Muss, + 318,Nachrichten-Endesegment,,UNT,0074,00061,,,Anzahl der Segmente in einerNachricht,X, + 319,Nachrichten-Endesegment,,UNT,0062,00061,,,Nachrichten-Referenznummer,X, + + ''' +# --- +# name: TestCli.test_kohlrahbi_cli_with_valid_arguments[37005] + ''' + ,Segmentname,Segmentgruppe,Segment,Datenelement,Segment ID,Code,Qualifier,Beschreibung,Bedingungsausdruck,Bedingung + 0,Nachrichten-Kopfsegment,,UNH,,00001,,,,Muss, + 1,Nachrichten-Kopfsegment,,UNH,0062,00001,,,Nachrichten-Referenznummer,X, + 2,Nachrichten-Kopfsegment,,UNH,0065,00001,PARTIN,,Partnerstammdaten,X, + 3,Nachrichten-Kopfsegment,,UNH,0052,00001,D,,Entwurfs-Version,X, + 4,Nachrichten-Kopfsegment,,UNH,0054,00001,20B,,Ausgabe 2020 - B,X, + 5,Nachrichten-Kopfsegment,,UNH,0051,00001,UN,,UN/CEFACT,X, + 6,Nachrichten-Kopfsegment,,UNH,0057,00001,1.0d,,Versionsnummer derzugrundeliegendenBDEW-Nachrichtenbeschreibung,X, + 7,Beginn der Nachricht,,BGM,,00002,,,,Muss, + 8,Beginn der Nachricht,,BGM,1001,00002,10,,Partnerstammdaten,X, + 9,Beginn der Nachricht,,BGM,1004,00002,,,Dokumentennummer,X, + 10,Beginn der Nachricht,,BGM,1373,00002,11,,Dokument nichtverfügbar,S [9],[9] Wenn die Kommunikationsdaten vom Absender nicht mehr aktiv sind. + 11,Nachrichtendatum,,DTM,,00003,,,,Muss, + 12,Nachrichtendatum,,DTM,2005,00003,137,,Dokumenten-/Nachrichtendatum/-zeit,X, + 13,Nachrichtendatum,,DTM,2380,00003,,,"Datum oder Uhrzeit oderZeitspanne, Wert",X [931][494],"[494] Das hier genannte Datum muss der Zeitpunkt sein, zu dem das Dokument erstellt wurde, oder ein Zeitpunkt, der davor liegt. + [931] Format: ZZZ = +00" + 14,Nachrichtendatum,,DTM,2379,00003,303,,CCYYMMDDHHMMZZZ,X, + 15,Prüfidentifikator,SG1,,,,,,,Muss, + 16,Prüfidentifikator,SG1,RFF,,00004,,,,Muss, + 17,Prüfidentifikator,SG1,RFF,1153,00004,Z13,,Prüfidentifikator,X, + 18,Prüfidentifikator,SG1,RFF,1154,00004,37003,,ÜbermittlungKommunikationsdatendes BKV,, + 19,Prüfidentifikator,SG1,RFF,1154,,37004,,ÜbermittlungKommunikationsdatendes BIKO,, + 20,Prüfidentifikator,SG1,RFF,1154,,37005,,ÜbermittlungKommunikationsdatendes ÜNB,X, + 21,Versionsnummer,SG1,,,,,,,Muss, + 22,Versionsnummer,SG1,RFF,,00005,,,,Muss, + 23,Versionsnummer,SG1,RFF,1153,00005,AGK,,Anwendungsreferenznummer,X, + 24,Versionsnummer,SG1,RFF,1056,00005,,,Versionsnummer,X [908][505],"[505] Wenn eine Vorgängerversion (RFF+ACW) angegeben ist, so muss der Wert in diesem DE1056 mindestens um 1 höher sein, als der Wert aus DE1056 der Vorgängerversion (RFF+ACW). + [908] Format: Mögliche Werte: 1 bis n" + 25,Gültig Ab,SG1,DTM,,00006,,,,Soll [4],[4] Wenn Vorgängerversion vorhanden + 26,Gültig Ab,SG1,DTM,2005,00006,157,,"Gültigkeit, Beginndatum",X, + 27,Gültig Ab,SG1,DTM,2380,00006,,,"Datum oder Uhrzeit oderZeitspanne, Wert",X [UB1], + 28,Gültig Ab,SG1,DTM,2379,00006,303,,CCYYMMDDHHMMZZZ,X, + 29,Vorgängerversion,SG1,,,,,,,Soll [4],[4] Wenn Vorgängerversion vorhanden + 30,Vorgängerversion,SG1,RFF,,00007,,,,Muss, + 31,Vorgängerversion,SG1,RFF,1153,00007,ACW,,Referenznummer einervorangegangenenNachricht,X, + 32,Vorgängerversion,SG1,RFF,1056,00007,,,Versionsnummer,X [908],[908] Format: Mögliche Werte: 1 bis n + 33,MP-ID Absender,SG2,,,,,,,Muss, + 34,MP-ID Absender,SG2,NAD,,00008,,,,Muss, + 35,MP-ID Absender,SG2,NAD,3035,00008,MS,,Dokumenten-/Nachrichtenausstellerbzw. -absender,X, + 36,MP-ID Absender,SG2,NAD,3039,00008,,,MP-ID,X [1],[1] Nur MP-ID aus Sparte Strom + 37,MP-ID Absender,SG2,NAD,3055,00008,9,,GS1,X, + 38,MP-ID Absender,SG2,NAD,3055,,293,,"DE, BDEW",X, + 39,Ansprechpartner,SG3,,,,,,,Kann, + 40,Ansprechpartner,SG3,CTA,,00009,,,,Muss, + 41,Ansprechpartner,SG3,CTA,3139,00009,IC,,Informationskontakt,X, + 42,Ansprechpartner,SG3,CTA,3412,00009,,,Name vom Ansprechpartner,X, + 43,Kommunikationsverbindung,SG3,COM,,00010,,,,Muss, + 44,Kommunikationsverbindung,SG3,COM,3148,00010,,,Nummer / Adresse,X (([939][6])∨ ([940][7]))∧ [502],"[6] wenn im DE3155 im demselben COM der Code EM vorhanden ist + [7] wenn im DE3155 im demselben COM der Code TE / FX / AJ / AL vorhanden ist + [502] Hinweis: Es darf nur eine Information im DE3148 übermittelt werden + [939] Format: Die Zeichenkette muss die Zeichen @ und . enthalten + [940] Format: Die Zeichenkette muss mit dem Zeichen + beginnen und danach dürfen nur noch Ziffern folgen" + 45,Kommunikationsverbindung,SG3,COM,3155,00010,EM,,Elektronische Post,X [1P0..1], + 46,Kommunikationsverbindung,SG3,COM,3155,,FX,,Telefax,X [1P0..1], + 47,Kommunikationsverbindung,SG3,COM,3155,,TE,,Telefon,X [1P0..1], + 48,Kommunikationsverbindung,SG3,COM,3155,,AJ,,weiteres Telefon,X [1P0..1], + 49,Kommunikationsverbindung,SG3,COM,3155,,AL,,Handy,X [1P0..1], + 50,MP-ID Empfänger,SG2,,,,,,,Muss, + 51,MP-ID Empfänger,SG2,NAD,,00011,,,,Muss, + 52,MP-ID Empfänger,SG2,NAD,3035,00011,MR,,Nachrichtenempfänger,X, + 53,MP-ID Empfänger,SG2,NAD,3039,00011,,,MP-ID,X [1],[1] Nur MP-ID aus Sparte Strom + 54,MP-ID Empfänger,SG2,NAD,3055,00011,9,,GS1,X, + 55,MP-ID Empfänger,SG2,NAD,3055,,293,,"DE, BDEW",X, + 56,Abschnitts-Kontrollsegment,,UNS,,00012,,,,Muss, + 57,Abschnitts-Kontrollsegment,,UNS,0081,00012,D,,Trennung von Kopf- undPositionsteil,X, + 58,Name und Adresse des Unternehmens,SG4,,,,,,,Muss [10],[10] Wenn BGM DE1373 = 11 (Dokument nicht verfügbar) nicht vorhanden + 59,Name und Adresse des Unternehmens,SG4,NAD,,00013,,,,Muss, + 60,Name und Adresse des Unternehmens,SG4,NAD,3035,00013,Z31,,Übertragungsnetzbetreiber,X, + 61,Name und Adresse des Unternehmens,SG4,NAD,3035,,Z34,,Bilanzkoordinator,, + 62,Name und Adresse des Unternehmens,SG4,NAD,3035,,Z35,,Bilanzkreisverantwortlicher,, + 63,Name und Adresse des Unternehmens,SG4,NAD,3036,00013,,,Name,X [506],"[506] Hinweis: Das Datenelement ist so zu füllen, dass sein Inhalt den Vorgaben des USt.- Gesetzes genügt, so dass der Empfänger diese Daten in einer INVOIC nutzen kann." + 64,Name und Adresse des Unternehmens,SG4,NAD,3045,00013,Z02,,Struktur derFirmenbezeichnung,X, + 65,Name und Adresse des Unternehmens,SG4,NAD,3042,00013,,,Straße und Hausnummer oderPostfach,X [506],"[506] Hinweis: Das Datenelement ist so zu füllen, dass sein Inhalt den Vorgaben des USt.- Gesetzes genügt, so dass der Empfänger diese Daten in einer INVOIC nutzen kann." + 66,Name und Adresse des Unternehmens,SG4,NAD,3164,00013,,,Ort,X [506],"[506] Hinweis: Das Datenelement ist so zu füllen, dass sein Inhalt den Vorgaben des USt.- Gesetzes genügt, so dass der Empfänger diese Daten in einer INVOIC nutzen kann." + 67,Name und Adresse des Unternehmens,SG4,NAD,3251,00013,,,Postleitzahl,M [2] ∧[506]S [3] ∧ [506],"[2] Wenn der Code im DE3207 in der ""EDI@Energy Codeliste der europäischen" + 68,Name und Adresse des Unternehmens,SG4,NAD,3207,00013,,,"Ländername, Code",X [506],"[506] Hinweis: Das Datenelement ist so zu füllen, dass sein Inhalt den Vorgaben des USt.- Gesetzes genügt, so dass der Empfänger diese Daten in einer INVOIC nutzen kann." + 69,Bankverbindung,SG4,FII,,00014,,,,Muss, + 70,Bankverbindung,SG4,FII,3035,00014,BK,,Kreditinstitut,X, + 71,Bankverbindung,SG4,FII,3194,00014,IBAN,,,X, + 72,Bankverbindung,SG4,FII,3192,00014,,,Name des Kontoinhabers,X, + 73,Bankverbindung,SG4,FII,3192,00014,,,Name des Kontoinhabers,K, + 74,Bankverbindung,SG4,FII,3433,00014,BIC,,,X, + 75,Bankverbindung,SG4,FII,3432,00014,,,Name des Kredinstituts,X, + 76,Internetseite (URL),SG4,FTX,,00015,,,,Muss, + 77,Internetseite (URL),SG4,FTX,4451,00015,Z13,,Internetseite,X, + 78,Internetseite (URL),SG4,FTX,4440,00015,,,Internetseite,X, + 79,Gericht und Handelsregister-Nummer,SG4,FTX,,00016,,,,Soll [3],[3] wenn vorhanden + 80,Gericht und Handelsregister-Nummer,SG4,FTX,4451,00016,Z15,,Gericht undHandelsregister-Nummer,X, + 81,Gericht und Handelsregister-Nummer,SG4,FTX,4440,00016,,,Gericht,X, + 82,Gericht und Handelsregister-Nummer,SG4,FTX,4440,00016,,,Handelsregister-Nummer,X, + 83,"Steuernummer, Umsatzsteuernummer",SG6,,,,,,,Muss, + 84,"Steuernummer, Umsatzsteuernummer",SG6,RFF,,00017,,,,Muss, + 85,"Steuernummer, Umsatzsteuernummer",SG6,RFF,1153,00017,VA,,Umsatzsteuernummer,X [2P0..1] ⊻[3P1..1], + 86,"Steuernummer, Umsatzsteuernummer",SG6,RFF,1153,,FC,,Steuernummer,X [2P0..1], + 87,"Steuernummer, Umsatzsteuernummer",SG6,RFF,1154,00017,,,"Referenz, Identifikation",X, + 88,Faxnummer,SG6,RFF,,00018,,,,Kann, + 89,Faxnummer,SG6,RFF,1153,00018,Z25,,Faxnummer,X, + 90,Faxnummer,SG6,RFF,1154,00018,,,Faxnummer,X [940],[940] Format: Die Zeichenkette muss mit dem Zeichen + beginnen und danach dürfen nur noch Ziffern folgen + 91,Erreichbarkeit an Werktagen,SG12,,,,,,,Muss, + 92,Erreichbarkeit an Werktagen,SG12,CCI,,00019,,,,Muss, + 93,Erreichbarkeit an Werktagen,SG12,CCI,7059,00019,Z40,,Erreichbarkeit desUnternehmens,X, + 94,Erreichbarkeit,SG12,DTM,,00020,,,,Muss, + 95,Erreichbarkeit,SG12,DTM,2005,00020,Z36,,Verfügbarkeit Montag,X [1P1..1], + 96,Erreichbarkeit,SG12,DTM,2005,,Z37,,Verfügbarkeit Dienstag,X [1P1..1], + 97,Erreichbarkeit,SG12,DTM,2005,,Z38,,Verfügbarkeit Mittwoch,X [1P1..1], + 98,Erreichbarkeit,SG12,DTM,2005,,Z39,,VerfügbarkeitDonnerstag,X [1P1..1], + 99,Erreichbarkeit,SG12,DTM,2005,,Z40,,Verfügbarkeit Freitag,X [1P1..1], + 100,Erreichbarkeit,SG12,DTM,2005,,Z41,,Mittagspause (=Ausschluss derVerfügbarkeit),X [1P0..1], + 101,Erreichbarkeit,SG12,DTM,2380,00020,,,"Datum oder Uhrzeit oderZeitspanne, Wert",X [503],[503] Hinweis: Angabe erfolgt in gesetzlicher deutscher Zeit + 102,Erreichbarkeit,SG12,DTM,2379,00020,501,,HHMMHHMM,X, + 103,Name und Anschrift Ansprechpartner Übertragungsweg / Datenaustausch,SG4,,,,,,,Muss [10],[10] Wenn BGM DE1373 = 11 (Dokument nicht verfügbar) nicht vorhanden + 104,Name und Anschrift Ansprechpartner Übertragungsweg / Datenaustausch,SG4,NAD,,00021,,,,Muss, + 105,Name und Anschrift Ansprechpartner Übertragungsweg / Datenaustausch,SG4,NAD,3035,00021,Z10,,Ansprechpartner,X, + 106,Name und Anschrift Ansprechpartner Übertragungsweg / Datenaustausch,SG4,NAD,3036,00021,,,Name,X [500],[500] Hinweis: Es kann der Firmenname eines Dienstleisters oder die identische Firmenbezeichnung aus SG4 NAD+SU / DDM / DEB / Z31 / Z34 / Z35 / Z36 eingetragen werden. + 107,Name und Anschrift Ansprechpartner Übertragungsweg / Datenaustausch,SG4,NAD,3045,00021,Z02,,Struktur derFirmenbezeichnung,X, + 108,Name und Anschrift Ansprechpartner Übertragungsweg / Datenaustausch,SG4,NAD,3042,00021,,,Straße und Hausnummer oderPostfach,X, + 109,Name und Anschrift Ansprechpartner Übertragungsweg / Datenaustausch,SG4,NAD,3164,00021,,,Ort,X, + 110,Name und Anschrift Ansprechpartner Übertragungsweg / Datenaustausch,SG4,NAD,3251,00021,,,Postleitzahl,M [2]S [3],"[2] Wenn der Code im DE3207 in der ""EDI@Energy Codeliste der europäischen Ländercodes"" in der Spalte ""PLZ vorhanden"" ein ""X"" enthält + [3] wenn vorhanden" + 111,Name und Anschrift Ansprechpartner Übertragungsweg / Datenaustausch,SG4,NAD,3207,00021,,,"Ländername, Code",X, + 112,Ansprechpartner,SG7,,,,,,,Muss, + 113,Ansprechpartner,SG7,CTA,,00022,,,,Muss, + 114,Ansprechpartner,SG7,CTA,3139,00022,IC,,Informationskontakt,X, + 115,Ansprechpartner,SG7,CTA,3412,00022,,,Name der organisatorischenEinheit,X [501],"[501] Hinweis: Es darf kein Name einer natürlichen Person übermittelt werden, stattdessen ist die organisatorische Einheit im Unternehmen zu nennen." + 116,Kommunikationsverbindung,SG7,COM,,00023,,,,Muss, + 117,Kommunikationsverbindung,SG7,COM,3148,00023,,,Nummer / Adresse,X (([939][6])∨ ([940][8]))∧ [502],"[6] wenn im DE3155 im demselben COM der Code EM vorhanden ist + [8] wenn im DE3155 im demselben COM der Code TE / FX vorhanden ist" + 118,Kommunikationsverbindung,SG7,COM,3155,00023,EM,,Elektronische Post,X [1P1..1], + 119,Kommunikationsverbindung,SG7,COM,3155,,TE,,Telefon,X [1P1..1], + 120,Kommunikationsverbindung,SG7,COM,3155,,FX,,Telefax,X [1P0..1], + 121,Name und Anschrift Ansprechpartner Rahmenverträge,SG4,,,,,,,Muss [10] ∧[36],"[10] Wenn BGM DE1373 = 11 (Dokument nicht verfügbar) nicht vorhanden + [35] Wenn MP-ID in SG2 NAD+MR (Nachrichtenempfänger) in der Rolle ÜNB + [36] Wenn MP-ID in SG2 NAD+MR (Nachrichtenempfänger) in der Rolle BKV" + 122,Name und Anschrift Ansprechpartner Rahmenverträge,SG4,NAD,,00024,,,,Muss, + 123,Name und Anschrift Ansprechpartner Rahmenverträge,SG4,NAD,3035,00024,Z11,,AnsprechpartnerRahmenverträge,X, + 124,Name und Anschrift Ansprechpartner Rahmenverträge,SG4,NAD,3036,00024,,,Name,X [500],[500] Hinweis: Es kann der Firmenname eines Dienstleisters oder die identische Firmenbezeichnung aus SG4 NAD+SU / DDM / DEB / Z31 / Z34 / Z35 / Z36 eingetragen werden. + 125,Name und Anschrift Ansprechpartner Rahmenverträge,SG4,NAD,3045,00024,Z02,,Struktur derFirmenbezeichnung,X, + 126,Name und Anschrift Ansprechpartner Rahmenverträge,SG4,NAD,3042,00024,,,Straße und Hausnummer oder,X, + 127,Name und Anschrift Ansprechpartner Rahmenverträge,SG4,NAD,3164,00024,,,Ort,X, + 128,Name und Anschrift Ansprechpartner Rahmenverträge,SG4,NAD,3251,00024,,,Postleitzahl,M [2]S [3],"[2] Wenn der Code im DE3207 in der ""EDI@Energy Codeliste der europäischen Ländercodes"" in der Spalte ""PLZ vorhanden"" ein ""X"" enthält + [3] wenn vorhanden" + 129,Name und Anschrift Ansprechpartner Rahmenverträge,SG4,NAD,3207,00024,,,"Ländername, Code",X, + 130,Ansprechpartner,SG7,,,,,,,Muss, + 131,Ansprechpartner,SG7,CTA,,00025,,,,Muss, + 132,Ansprechpartner,SG7,CTA,3139,00025,IC,,Informationskontakt,X, + 133,Ansprechpartner,SG7,CTA,3412,00025,,,Name der organisatorischenEinheit,X [501],"[501] Hinweis: Es darf kein Name einer natürlichen Person übermittelt werden, stattdessen ist die organisatorische Einheit im Unternehmen zu nennen." + 134,Kommunikationsverbindung,SG7,COM,,00026,,,,Muss, + 135,Kommunikationsverbindung,SG7,COM,3148,00026,,,Nummer / Adresse,X (([939][6])∨ ([940][8]))∧ [502],"[6] wenn im DE3155 im demselben COM der Code EM vorhanden ist + [8] wenn im DE3155 im demselben COM der Code TE / FX vorhanden ist + [502] Hinweis: Es darf nur eine Information im DE3148 übermittelt werden + [939] Format: Die Zeichenkette muss die Zeichen @ und . enthalten + [940] Format: Die Zeichenkette muss mit dem Zeichen + beginnen" + 136,Kommunikationsverbindung,SG7,COM,3155,00026,EM,,Elektronische Post,X [1P1..1], + 137,Kommunikationsverbindung,SG7,COM,3155,,TE,,Telefon,X [1P1..1], + 138,Kommunikationsverbindung,SG7,COM,3155,,FX,,Telefax,X [1P0..1], + 139,Name und Anschrift Ansprechpartner Stammdatenprozesse,SG4,,,,,,,Muss [10] ∧[17],"[10] Wenn BGM DE1373 = 11 (Dokument nicht verfügbar) nicht vorhanden + [17] Wenn MP-ID in SG2 NAD+MR (Nachrichtenempfänger) in der Rolle LF/NB/MSB" + 140,Name und Anschrift Ansprechpartner Stammdatenprozesse,SG4,NAD,,00033,,,,Muss, + 141,Name und Anschrift Ansprechpartner Stammdatenprozesse,SG4,NAD,3035,00033,Z14,,AnsprechpartnerStammdatenprozesse,X, + 142,Name und Anschrift Ansprechpartner Stammdatenprozesse,SG4,NAD,3036,00033,,,Name,X [500],[500] Hinweis: Es kann der Firmenname eines Dienstleisters oder die identische Firmenbezeichnung aus SG4 NAD+SU / DDM / DEB / Z31 / Z34 / Z35 / Z36 eingetragen werden. + 143,Name und Anschrift Ansprechpartner Stammdatenprozesse,SG4,NAD,3045,00033,Z02,,Struktur derFirmenbezeichnung,X, + 144,Name und Anschrift Ansprechpartner Stammdatenprozesse,SG4,NAD,3042,00033,,,Straße und Hausnummer oderPostfach,X, + 145,Name und Anschrift Ansprechpartner Stammdatenprozesse,SG4,NAD,3164,00033,,,Ort,X, + 146,Name und Anschrift Ansprechpartner Stammdatenprozesse,SG4,NAD,3251,00033,,,Postleitzahl,M [2]S [3],"[2] Wenn der Code im DE3207 in der ""EDI@Energy Codeliste der europäischen Ländercodes"" in der Spalte ""PLZ vorhanden"" ein ""X"" enthält + [3] wenn vorhanden" + 147,Name und Anschrift Ansprechpartner Stammdatenprozesse,SG4,NAD,3207,00033,,,"Ländername, Code",X, + 148,Ansprechpartner,SG7,,,,,,,Muss, + 149,Ansprechpartner,SG7,CTA,,00034,,,,Muss, + 150,Ansprechpartner,SG7,CTA,3139,00034,IC,,Informationskontakt,X, + 151,Ansprechpartner,SG7,CTA,3412,00034,,,Name der organisatorischen,X [501],[501] Hinweis: Es darf + 152,Kommunikationsverbindung,SG7,COM,,00035,,,,Muss, + 153,Kommunikationsverbindung,SG7,COM,3148,00035,,,Nummer / Adresse,X (([939][6])∨ ([940][8]))∧ [502],"[6] wenn im DE3155 im demselben COM der Code EM vorhanden ist + [8] wenn im DE3155 im demselben COM der Code TE / FX vorhanden ist + [502] Hinweis: Es darf nur eine Information im DE3148 übermittelt werden + [939] Format: Die Zeichenkette muss die Zeichen @ und . enthalten + [940] Format: Die Zeichenkette muss mit dem Zeichen + beginnen und danach dürfen nur noch Ziffern folgen" + 154,Kommunikationsverbindung,SG7,COM,3155,00035,EM,,Elektronische Post,X [1P1..1], + 155,Kommunikationsverbindung,SG7,COM,3155,,TE,,Telefon,X [1P1..1], + 156,Kommunikationsverbindung,SG7,COM,3155,,FX,,Telefax,X [1P0..1], + 157,Name und Anschrift Ansprechpartner MMMA- Prozesse,SG4,,,,,,,Muss [10] ∧ [25],"[10] Wenn BGM DE1373 = 11 (Dokument nicht verfügbar) nicht vorhanden + [25] Wenn MP-ID in SG2 NAD+MR (Nachrichtenempfänger) in der Rolle NB" + 158,Name und Anschrift Ansprechpartner MMMA- Prozesse,SG4,NAD,,00042,,,,Muss, + 159,Name und Anschrift Ansprechpartner MMMA- Prozesse,SG4,NAD,3035,00042,Z18,,AnsprechpartnerMMMA-Prozesse,X, + 160,Name und Anschrift Ansprechpartner MMMA- Prozesse,SG4,NAD,3036,00042,,,Name,X [500],[500] Hinweis: Es kann der Firmenname eines Dienstleisters oder die identische Firmenbezeichnung aus SG4 NAD+SU / DDM / DEB / Z31 / Z34 / Z35 / Z36 eingetragen werden. + 161,Name und Anschrift Ansprechpartner MMMA- Prozesse,SG4,NAD,3045,00042,Z02,,Struktur derFirmenbezeichnung,X, + 162,Name und Anschrift Ansprechpartner MMMA- Prozesse,SG4,NAD,3042,00042,,,Straße und Hausnummer oderPostfach,X, + 163,Name und Anschrift Ansprechpartner MMMA- Prozesse,SG4,NAD,3164,00042,,,Ort,X, + 164,Name und Anschrift Ansprechpartner MMMA- Prozesse,SG4,NAD,3251,00042,,,Postleitzahl,M [2]S [3],"[2] Wenn der Code im DE3207 in der ""EDI@Energy Codeliste der europäischen Ländercodes"" in der Spalte ""PLZ vorhanden"" ein ""X"" enthält + [3] wenn vorhanden" + 165,Name und Anschrift Ansprechpartner MMMA- Prozesse,SG4,NAD,3207,00042,,,"Ländername, Code",X, + 166,Ansprechpartner,SG7,,,,,,,Muss, + 167,Ansprechpartner,SG7,CTA,,00043,,,,Muss, + 168,Ansprechpartner,SG7,CTA,3139,00043,IC,,Informationskontakt,X, + 169,Ansprechpartner,SG7,CTA,3412,00043,,,Name der organisatorischenEinheit,X [501],"[501] Hinweis: Es darf kein Name einer natürlichen Person übermittelt werden, stattdessen ist die organisatorische Einheit im Unternehmen zu nennen." + 170,Kommunikationsverbindung,SG7,COM,,00044,,,,Muss, + 171,Kommunikationsverbindung,SG7,COM,3148,00044,,,Nummer / Adresse,X (([939][6])∨ ([940][8]))∧ [502],"[6] wenn im DE3155 im demselben COM der Code EM vorhanden ist + [8] wenn im DE3155 im demselben COM der Code TE / FX vorhanden" + 172,Kommunikationsverbindung,SG7,COM,3155,00044,EM,,Elektronische Post,X [1P1..1], + 173,Kommunikationsverbindung,SG7,COM,3155,,TE,,Telefon,X [1P1..1], + 174,Kommunikationsverbindung,SG7,COM,3155,,FX,,Telefax,X [1P0..1], + 175,Name und Anschrift Bewegungsdaten,SG4,,,,,,,Muss [10] ∧[17],"[10] Wenn BGM DE1373 = 11 (Dokument nicht verfügbar) nicht vorhanden + [17] Wenn MP-ID in SG2 NAD+MR (Nachrichtenempfänger) in der Rolle LF/NB/MSB" + 176,Name und Anschrift Bewegungsdaten,SG4,NAD,,00045,,,,Muss, + 177,Name und Anschrift Bewegungsdaten,SG4,NAD,3035,00045,Z19,,AnsprechpartnerBewegungsdaten,X, + 178,Name und Anschrift Bewegungsdaten,SG4,NAD,3036,00045,,,Name,X [500],[500] Hinweis: Es kann der Firmenname eines Dienstleisters oder die identische Firmenbezeichnung aus SG4 NAD+SU / DDM / DEB / Z31 / Z34 / Z35 / Z36 eingetragen werden. + 179,Name und Anschrift Bewegungsdaten,SG4,NAD,3045,00045,Z02,,Struktur derFirmenbezeichnung,X, + 180,Name und Anschrift Bewegungsdaten,SG4,NAD,3042,00045,,,Straße und Hausnummer oderPostfach,X, + 181,Name und Anschrift Bewegungsdaten,SG4,NAD,3164,00045,,,Ort,X, + 182,Name und Anschrift Bewegungsdaten,SG4,NAD,3251,00045,,,Postleitzahl,M [2]S [3],[2] Wenn der Code im DE3207 in der + 183,Name und Anschrift Bewegungsdaten,SG4,NAD,3207,00045,,,"Ländername, Code",X, + 184,Ansprechpartner,SG7,,,,,,,Muss, + 185,Ansprechpartner,SG7,CTA,,00046,,,,Muss, + 186,Ansprechpartner,SG7,CTA,3139,00046,IC,,Informationskontakt,X, + 187,Ansprechpartner,SG7,CTA,3412,00046,,,Name der organisatorischenEinheit,X [501],"[501] Hinweis: Es darf kein Name einer natürlichen Person übermittelt werden, stattdessen ist die organisatorische Einheit im Unternehmen zu nennen." + 188,Kommunikationsverbindung,SG7,COM,,00047,,,,Muss, + 189,Kommunikationsverbindung,SG7,COM,3148,00047,,,Nummer / Adresse,X (([939][6])∨ ([940][8]))∧ [502],"[6] wenn im DE3155 im demselben COM der Code EM vorhanden ist + [8] wenn im DE3155 im demselben COM der Code TE / FX vorhanden ist + [502] Hinweis: Es darf nur eine Information im DE3148 übermittelt werden + [939] Format: Die Zeichenkette muss die Zeichen @ und . enthalten + [940] Format: Die Zeichenkette muss mit dem Zeichen + beginnen und danach dürfen nur noch Ziffern folgen" + 190,Kommunikationsverbindung,SG7,COM,3155,00047,EM,,Elektronische Post,X [1P1..1], + 191,Kommunikationsverbindung,SG7,COM,3155,,TE,,Telefon,X [1P1..1], + 192,Name und Anschrift Ansprechpartner Prozesse zur Unterbrechung und Wiederherstellung der Anschlussnutzung,SG4,,,,,,,Muss [10] ∧[25],"[10] Wenn BGM DE1373 = 11 (Dokument nicht verfügbar) nicht vorhanden + [25] Wenn MP-ID in SG2 NAD+MR (Nachrichtenempfänger) in der Rolle NB" + 193,Name und Anschrift Ansprechpartner Prozesse zur Unterbrechung und Wiederherstellung der Anschlussnutzung,SG4,NAD,,00048,,,,Muss, + 194,Name und Anschrift Ansprechpartner Prozesse zur Unterbrechung und Wiederherstellung der Anschlussnutzung,SG4,NAD,3035,00048,Z20,,AnsprechpartnerSperr-/Entsperrprozesse,X, + 195,Name und Anschrift Ansprechpartner Prozesse zur Unterbrechung und Wiederherstellung der Anschlussnutzung,SG4,NAD,3036,00048,,,Name,X [500],[500] Hinweis: Es kann der Firmenname eines Dienstleisters oder die identische Firmenbezeichnung aus SG4 NAD+SU / DDM / DEB / Z31 / Z34 / Z35 / Z36 eingetragen werden. + 196,Name und Anschrift Ansprechpartner Prozesse zur Unterbrechung und Wiederherstellung der Anschlussnutzung,SG4,NAD,3045,00048,Z02,,Struktur derFirmenbezeichnung,X, + 197,Name und Anschrift Ansprechpartner Prozesse zur Unterbrechung und Wiederherstellung der Anschlussnutzung,SG4,NAD,3042,00048,,,Straße und Hausnummer oderPostfach,X, + 198,Name und Anschrift Ansprechpartner Prozesse zur Unterbrechung und Wiederherstellung der Anschlussnutzung,SG4,NAD,3164,00048,,,Ort,X, + 199,Name und Anschrift Ansprechpartner Prozesse zur Unterbrechung und Wiederherstellung der Anschlussnutzung,SG4,NAD,3251,00048,,,Postleitzahl,M [2]S [3],"[2] Wenn der Code im DE3207 in der ""EDI@Energy Codeliste der europäischen Ländercodes"" in der Spalte ""PLZ vorhanden"" ein ""X"" enthält + [3] wenn vorhanden" + 200,Name und Anschrift Ansprechpartner Prozesse zur Unterbrechung und Wiederherstellung der Anschlussnutzung,SG4,NAD,3207,00048,,,"Ländername, Code",X, + 201,Ansprechpartner,SG7,,,,,,,Muss, + 202,Ansprechpartner,SG7,CTA,,00049,,,,Muss, + 203,Ansprechpartner,SG7,CTA,3139,00049,IC,,Informationskontakt,X, + 204,Ansprechpartner,SG7,CTA,3412,00049,,,Name der organisatorischenEinheit,X [501],[501] Hinweis: Es darf kein Name einer natürlichen Person + 205,Kommunikationsverbindung,SG7,COM,,00050,,,,Muss, + 206,Kommunikationsverbindung,SG7,COM,3148,00050,,,Nummer / Adresse,X (([939][6])∨ ([940][8]))∧ [502],"[6] wenn im DE3155 im demselben COM der Code EM vorhanden ist + [8] wenn im DE3155 im demselben COM der Code TE / FX vorhanden ist + [502] Hinweis: Es darf nur eine Information im DE3148 übermittelt werden + [939] Format: Die Zeichenkette muss die Zeichen @ und . enthalten + [940] Format: Die Zeichenkette muss mit dem Zeichen + beginnen und danach dürfen nur noch Ziffern folgen" + 207,Kommunikationsverbindung,SG7,COM,3155,00050,EM,,Elektronische Post,X [1P1..1], + 208,Kommunikationsverbindung,SG7,COM,3155,,TE,,Telefon,X [1P1..1], + 209,Kommunikationsverbindung,SG7,COM,3155,,FX,,Telefax,X [1P0..1], + 210,Name und Anschrift Ansprechpartner Bilanzierungsprozesse / Bilanzkreismanagement,SG4,,,,,,,Muss [10] ∧[26],"[10] Wenn BGM DE1373 = 11 (Dokument nicht verfügbar) nicht vorhanden + [26] Wenn MP-ID in SG2 NAD+MR (Nachrichtenempfänger) in der Rolle NB/LF/BKV/ BIKO" + 211,Name und Anschrift Ansprechpartner Bilanzierungsprozesse / Bilanzkreismanagement,SG4,NAD,,00051,,,,Muss, + 212,Name und Anschrift Ansprechpartner Bilanzierungsprozesse / Bilanzkreismanagement,SG4,NAD,3035,00051,Z21,,AnsprechpartnerBilanzierungsprozesse /Bilanzkreismanagement,X, + 213,Name und Anschrift Ansprechpartner Bilanzierungsprozesse / Bilanzkreismanagement,SG4,NAD,3036,00051,,,Name,X [500],[500] Hinweis: Es kann der Firmenname eines Dienstleisters oder die identische Firmenbezeichnung aus SG4 NAD+SU / DDM / DEB / Z31 / Z34 / Z35 / Z36 eingetragen werden. + 214,Name und Anschrift Ansprechpartner Bilanzierungsprozesse / Bilanzkreismanagement,SG4,NAD,3045,00051,Z02,,Struktur derFirmenbezeichnung,X, + 215,Name und Anschrift Ansprechpartner Bilanzierungsprozesse / Bilanzkreismanagement,SG4,NAD,3042,00051,,,Straße und Hausnummer oderPostfach,X, + 216,Name und Anschrift Ansprechpartner Bilanzierungsprozesse / Bilanzkreismanagement,SG4,NAD,3164,00051,,,Ort,X, + 217,Name und Anschrift Ansprechpartner Bilanzierungsprozesse / Bilanzkreismanagement,SG4,NAD,3251,00051,,,Postleitzahl,M [2]S [3],"[2] Wenn der Code im DE3207 in der ""EDI@Energy Codeliste der europäischen Ländercodes"" in der Spalte ""PLZ vorhanden"" ein ""X"" enthält + [3] wenn vorhanden" + 218,Name und Anschrift Ansprechpartner Bilanzierungsprozesse / Bilanzkreismanagement,SG4,NAD,3207,00051,,,"Ländername, Code",X, + 219,Ansprechpartner,SG7,,,,,,,Muss, + 220,Ansprechpartner,SG7,CTA,,00052,,,,Muss, + 221,Ansprechpartner,SG7,CTA,3139,00052,IC,,Informationskontakt,X, + 222,Ansprechpartner,SG7,CTA,3412,00052,,,Name der organisatorischenEinheit,X [501],"[501] Hinweis: Es darf kein Name einer natürlichen Person übermittelt werden, stattdessen ist die organisatorische Einheit im Unternehmen zu nennen." + 223,Kommunikationsverbindung,SG7,COM,,00053,,,,Muss, + 224,Kommunikationsverbindung,SG7,COM,3148,00053,,,Nummer / Adresse,X (([939][6])∨ ([940][8]))∧ [502],"[6] wenn im DE3155 im demselben COM der Code EM vorhanden ist + [8] wenn im DE3155 im demselben COM der" + 225,Kommunikationsverbindung,SG7,COM,3155,00053,EM,,Elektronische Post,X [1P1..1], + 226,Kommunikationsverbindung,SG7,COM,3155,,TE,,Telefon,X [1P1..1], + 227,Kommunikationsverbindung,SG7,COM,3155,,FX,,Telefax,X [1P0..1], + 228,Nachrichten-Endesegment,,UNT,,00061,,,,Muss, + 229,Nachrichten-Endesegment,,UNT,0074,00061,,,Anzahl der Segmente in einerNachricht,X, + 230,Nachrichten-Endesegment,,UNT,0062,00061,,,Nachrichten-Referenznummer,X, + + ''' +# --- +# name: TestCli.test_kohlrahbi_cli_with_valid_arguments[39000] + ''' + ,Segmentname,Segmentgruppe,Segment,Datenelement,Segment ID,Code,Qualifier,Beschreibung,Bedingungsausdruck,Bedingung + 0,Nachrichten-Kopfsegment,,UNH,,00001,,,,Muss, + 1,Nachrichten-Kopfsegment,,UNH,0062,00001,,,Nachrichten-Referenznummer,X, + 2,Nachrichten-Kopfsegment,,UNH,0065,00001,ORDCHG,,Bestelländerung,X, + 3,Nachrichten-Kopfsegment,,UNH,0052,00001,D,,Entwurfs-Version,X, + 4,Nachrichten-Kopfsegment,,UNH,0054,00001,20B,,Ausgabe 2020 - B,X, + 5,Nachrichten-Kopfsegment,,UNH,0051,00001,UN,,UN/CEFACT,X, + 6,Nachrichten-Kopfsegment,,UNH,0057,00001,1.1,,Versionsnummer derzugrundeliegendenBDEW-Nachrichtenbeschreibung,X, + 7,Beginn der Nachricht,,BGM,,00002,,,,Muss, + 8,Beginn der Nachricht,,BGM,1001,00002,Z51,,Sperrung,X, + 9,Beginn der Nachricht,,BGM,1001,,Z52,,Entsperrung,X, + 10,Beginn der Nachricht,,BGM,1004,00002,,,Dokumentennummer,X, + 11,Beginn der Nachricht,,BGM,1225,00002,1,,Aufhebung/Stornierung,X, + 12,Nachrichtendatum,,DTM,,00003,,,,Muss, + 13,Nachrichtendatum,,DTM,2005,00003,137,,Dokumenten-/Nachrichtendatum/-zeit,X, + 14,Nachrichtendatum,,DTM,2380,00003,,,"Datum oder Uhrzeit oderZeitspanne, Wert",X [931] [494],"[494] Das hier genannte Datum muss der Zeitpunkt sein, zu dem das Dokument erstellt wurde, oder ein Zeitpunkt, der davor liegt. + [931] Format: ZZZ = +00" + 15,Nachrichtendatum,,DTM,2379,00003,303,,CCYYMMDDHHMMZZZ,X, + 16,Nachrichtennummer der Anfrage/Bestellung,SG1,,,,,,,Muss, + 17,Nachrichtennummer der Anfrage/Bestellung,SG1,RFF,,00004,,,,Muss, + 18,Nachrichtennummer der Anfrage/Bestellung,SG1,RFF,1153,00004,ON,,Auftragsnummer(Einkauf),X, + 19,Nachrichtennummer der Anfrage/Bestellung,SG1,RFF,1154,00004,,,Nachrichtennummer,X [500],"[2] Wenn BGM+Z51 (Sperrung) vorhanden + [3] Wenn BGM+Z52 (Entsperrung) vorhanden + [500] Hinweis: Dokumentennummer aus BGM DE1004 der ORDERS + [501] Hinweis: Wert aus BGM+Z33 DE1004 der IFTSTA mit der die Information über den Entsperrauftrag übermittelt wurde" + 20,Vorgangsnummer der Anfrage/Bestellung,SG1,RFF,,00005,,,,,[3] Wenn BGM+Z52 (Entsperrung) vorhanden + 21,Vorgangsnummer der Anfrage/Bestellung,SG1,RFF,1153,00005,TN,,Transaktions-Referenznummer,, + 22,Vorgangsnummer der Anfrage/Bestellung,SG1,RFF,1154,00005,,,Vorgangsnummer,,[502] Hinweis: Vorgangsnummer aus CNI DE1490 der IFTSTA mit BGM+Z33 mit der die Information über den Entsperrauftrag übermittelt wurde + 23,Prüfidentifikator,SG1,,,,,,,Muss, + 24,Prüfidentifikator,SG1,RFF,,00006,,,,Muss, + 25,Prüfidentifikator,SG1,RFF,1153,00006,Z13,,Prüfidentifikator,X, + 26,Prüfidentifikator,SG1,RFF,1154,00006,39000,,Stornierung Sperr-/Entsperrauftrag,X, + 27,Prüfidentifikator,SG1,RFF,1154,,39001,,Weiterleitung derStornierung,, + 28,MP-ID Absender,SG3,,,,,,,Muss, + 29,MP-ID Absender,SG3,NAD,,00007,,,,Muss, + 30,MP-ID Absender,SG3,NAD,3035,00007,MS,,Dokumenten-/Nachrichtenausstellerbzw. -absender,X, + 31,MP-ID Absender,SG3,NAD,3039,00007,,,MP-ID,X, + 32,MP-ID Absender,SG3,NAD,3055,00007,9,,GS1,X, + 33,MP-ID Absender,SG3,NAD,3055,,293,,"DE, BDEW(Bundesverband derEnergie- undWasserwirtschaft e.V.)",X, + 34,MP-ID Absender,SG3,NAD,3055,,332,,"DE, DVGW Service &Consult GmbH",X, + 35,Ansprechpartner,SG6,,,,,,,Kann, + 36,Ansprechpartner,SG6,CTA,,00008,,,,Muss, + 37,Ansprechpartner,SG6,CTA,3139,00008,IC,,Informationskontakt,X, + 38,Ansprechpartner,SG6,CTA,3412,00008,,,Kontakt,X, + 39,Kommunikationsverbindung,SG6,COM,,00009,,,,Muss, + 40,Kommunikationsverbindung,SG6,COM,3148,00009,,,"Kommunikationsadresse,Identifikation",X, + 41,Kommunikationsverbindung,SG6,COM,3155,00009,EM,,Elektronische Post,X [1P0..1], + 42,Kommunikationsverbindung,SG6,COM,3155,,FX,,Telefax,X [1P0..1], + 43,Kommunikationsverbindung,SG6,COM,3155,,TE,,Telefon,X [1P0..1], + 44,Kommunikationsverbindung,SG6,COM,3155,,AJ,,weiteres Telefon,X [1P0..1], + 45,Kommunikationsverbindung,SG6,COM,3155,,AL,,Handy,X [1P0..1], + 46,MP-ID Empfänger,SG3,,,,,,,Muss, + 47,MP-ID Empfänger,SG3,NAD,,00010,,,,Muss, + 48,MP-ID Empfänger,SG3,NAD,3035,00010,MR,,Nachrichtenempfänger,X, + 49,MP-ID Empfänger,SG3,NAD,3039,00010,,,MP-ID,X, + 50,MP-ID Empfänger,SG3,NAD,3055,00010,9,,GS1,X, + 51,Abschnitts-Kontrollsegment,,UNS,,00011,,,,Muss, + 52,Abschnitts-Kontrollsegment,,UNS,0081,00011,S,,Trennung von Positions-und Summenteil,X, + 53,Nachrichten-Endesegment,,UNT,,00012,,,,Muss, + 54,Nachrichten-Endesegment,,UNT,0074,00012,,,Anzahl der Segmente in einerNachricht,X, + 55,Nachrichten-Endesegment,,UNT,0062,00012,,,Nachrichten-Referenznummer,X, + + ''' +# --- +# name: TestCli.test_kohlrahbi_cli_with_valid_arguments[39002] + ''' + ,Segmentname,Segmentgruppe,Segment,Datenelement,Segment ID,Code,Qualifier,Beschreibung,Bedingungsausdruck,Bedingung + 0,Nachrichten-Kopfsegment,,UNH,,00001,,,,Muss, + 1,Nachrichten-Kopfsegment,,UNH,0062,00001,,,Nachrichten-Referenznummer,X, + 2,Nachrichten-Kopfsegment,,UNH,0065,00001,ORDCHG,,Bestelländerung,X, + 3,Nachrichten-Kopfsegment,,UNH,0052,00001,D,,Entwurfs-Version,X, + 4,Nachrichten-Kopfsegment,,UNH,0054,00001,20B,,Ausgabe 2020 - B,X, + 5,Nachrichten-Kopfsegment,,UNH,0051,00001,UN,,UN/CEFACT,X, + 6,Nachrichten-Kopfsegment,,UNH,0057,00001,1.1,,Versionsnummer derzugrundeliegendenBDEW-Nachrichtenbeschreibung,X, + 7,Beginn der Nachricht,,BGM,,00002,,,,Muss, + 8,Beginn der Nachricht,,BGM,1001,00002,Z57,,Übermittlung von Wertenan ESA,X, + 9,Beginn der Nachricht,,BGM,1004,00002,,,Dokumentennummer,X, + 10,Beginn der Nachricht,,BGM,1225,00002,,,,1, + 11,Nachrichtendatum,,DTM,,00003,,,,Muss, + 12,Nachrichtendatum,,DTM,2005,00003,137,,Dokumenten-/Nachrichtendatum/-zeit,X, + 13,Nachrichtendatum,,DTM,2380,00003,,,"Datum oder Uhrzeit oderZeitspanne, Wert",X [931] [494],"[494] Das hier genannte Datum muss der Zeitpunkt sein, zu dem das Dokument erstellt wurde, oder ein Zeitpunkt, der davor liegt. + [931] Format: ZZZ = +00" + 14,Nachrichtendatum,,DTM,2379,00003,303,,CCYYMMDDHHMMZZZ,X, + 15,Nachrichtennummer der Anfrage/Bestellung,SG1,,,,,,,Muss, + 16,Nachrichtennummer der Anfrage/Bestellung,SG1,RFF,,00004,,,,Muss, + 17,Nachrichtennummer der Anfrage/Bestellung,SG1,RFF,1153,00004,ON,,Auftragsnummer (Einkauf),X, + 18,Nachrichtennummer der Anfrage/Bestellung,SG1,RFF,1154,00004,,,Nachrichtennummer,X [500],[500] Hinweis: Dokumentennummer aus BGM DE1004 der ORDERS + 19,Prüfidentifikator,SG1,,,,,,,Muss, + 20,Prüfidentifikator,SG1,RFF,,00006,,,,Muss, + 21,Prüfidentifikator,SG1,RFF,1153,00006,Z13,,Prüfidentifikator,X, + 22,Prüfidentifikator,SG1,RFF,1154,00006,39002,,Stornierung der Bestellungfür ESA,X, + 23,MP-ID Absender,SG3,,,,,,,Muss, + 24,MP-ID Absender,SG3,NAD,,00007,,,,Muss, + 25,MP-ID Absender,SG3,NAD,3035,00007,Nachrichtenaussteller bzw.-absender,,,MS, + 26,MP-ID Absender,SG3,NAD,3039,00007,,,MP-ID,X [1],[1] MP-ID nur aus Sparte Strom + 27,MP-ID Absender,SG3,NAD,3055,00007,9,,GS1,X, + 28,MP-ID Absender,SG3,NAD,3055,,293,,"DE, BDEW (Bundesverband",X, + 29,Ansprechpartner,SG6,,,,,,,Kann, + 30,Ansprechpartner,SG6,CTA,,00008,,,,Muss, + 31,Ansprechpartner,SG6,CTA,3139,00008,,,,IC, + 32,Ansprechpartner,SG6,CTA,3412,00008,,,Kontakt,X, + 33,Kommunikationsverbindung,SG6,COM,,00009,,,,Muss, + 34,Kommunikationsverbindung,SG6,COM,3148,00009,,,"Kommunikationsadresse,Identifikation",X, + 35,Kommunikationsverbindung,SG6,COM,3155,00009,EM,,Elektronische Post,X [1P0..1], + 36,Kommunikationsverbindung,SG6,COM,3155,,FX,,Telefax,X [1P0..1], + 37,Kommunikationsverbindung,SG6,COM,3155,,TE,,Telefon,X [1P0..1], + 38,Kommunikationsverbindung,SG6,COM,3155,,AJ,,weiteres Telefon,X [1P0..1], + 39,Kommunikationsverbindung,SG6,COM,3155,,AL,,Handy,X [1P0..1], + 40,MP-ID Empfänger,SG3,,,,,,,Muss, + 41,MP-ID Empfänger,SG3,NAD,,00010,,,,Muss, + 42,MP-ID Empfänger,SG3,NAD,3035,00010,,,,MR, + 43,MP-ID Empfänger,SG3,NAD,3039,00010,,,MP-ID,X [1],[1] MP-ID nur aus Sparte Strom + 44,MP-ID Empfänger,SG3,NAD,3055,00010,9,,GS1,X, + 45,MP-ID Empfänger,SG3,NAD,3055,,293,,"DE, BDEW (Bundesverbandder Energie- undWasserwirtschaft e.V.)",X, + 46,Abschnitts-Kontrollsegment,,UNS,,00011,,,,Muss, + 47,Abschnitts-Kontrollsegment,,UNS,0081,00011,und Summenteil,,,S, + 48,Nachrichten-Endesegment,,UNT,,00012,,,,Muss, + 49,Nachrichten-Endesegment,,UNT,0074,00012,,,Anzahl der Segmente in einerNachricht,X, + 50,Nachrichten-Endesegment,,UNT,0062,00012,,,Nachrichten-Referenznummer,X, + + ''' +# --- +# name: TestCli.test_kohlrahbi_cli_with_valid_arguments[44001] + ''' + ,Segmentname,Segmentgruppe,Segment,Datenelement,Segment ID,Code,Qualifier,Beschreibung,Bedingungsausdruck,Bedingung + 0,Nachrichten-Kopfsegment,,UNH,,00003,,,,Muss, + 1,Nachrichten-Kopfsegment,,UNH,0062,00003,,,Nachrichten-Referenznummer,X, + 2,Nachrichten-Kopfsegment,,UNH,0065,00003,UTILMD,,Netzanschluss-Stammdaten,X, + 3,Nachrichten-Kopfsegment,,UNH,0052,00003,D,,Entwurfs-Version,X, + 4,Nachrichten-Kopfsegment,,UNH,0054,00003,11A,,Ausgabe 2011 - A,X, + 5,Nachrichten-Kopfsegment,,UNH,0051,00003,UN,,UN/CEFACT,X, + 6,Nachrichten-Kopfsegment,,UNH,0057,00003,Versionsnummer derzugrundeliegendenBDEW-Nachrichtenbeschreibung,,G1.0a,X, + 7,Beginn der Nachricht,,BGM,,00004,,,,Muss, + 8,Beginn der Nachricht,,BGM,1001,00004,E01,,Anmeldungen,X, + 9,Beginn der Nachricht,,BGM,1004,00004,,,Dokumentennummer,X, + 10,Nachrichtendatum,,DTM,,00005,,,,Muss, + 11,Nachrichtendatum,,DTM,2005,00005,137,,Dokumenten-/Nachrichtendatum/-zeit,X, + 12,Nachrichtendatum,,DTM,2380,00005,,,"Datum oder Uhrzeit oderZeitspanne, Wert",X [931][494],"[494] Das hier genannte Datum muss der Zeitpunkt sein, zu dem das Dokument erstellt wurde, oder ein Zeitpunkt, der davor liegt + [931] Format: ZZZ = +00" + 13,Nachrichtendatum,,DTM,2379,00005,303,,CCYYMMDDHHMMZZZ,X, + 14,MP-ID Absender,SG2,,,,,,,Muss, + 15,MP-ID Absender,SG2,NAD,,00008,,,,Muss, + 16,MP-ID Absender,SG2,NAD,3035,00008,MS,,Dokumenten-/Nachrichtenausstellerbzw. -absender,X, + 17,MP-ID Absender,SG2,NAD,3039,00008,,,MP-ID,X, + 18,MP-ID Absender,SG2,NAD,3055,00008,9,,GS1,X, + 19,MP-ID Absender,SG2,NAD,3055,,332,,"DE, DVGW Service &Consult GmbH",X, + 20,Ansprechpartner,SG3,,,,,,,Kann, + 21,Ansprechpartner,SG3,CTA,,00009,,,,Muss, + 22,Ansprechpartner,SG3,CTA,3139,00009,IC,,Informationskontakt,X, + 23,Ansprechpartner,SG3,CTA,3412,00009,,,Name vom Ansprechpartner,X, + 24,Kommunikationsverbindung,SG3,COM,,00010,,,,Muss, + 25,Kommunikationsverbindung,SG3,COM,3148,00010,,,Nummer / Adresse,X, + 26,Kommunikationsverbindung,SG3,COM,3155,00010,EM,,Elektronische Post,X [1P0..1], + 27,MP-ID Empfänger,SG2,,,,,,,Muss, + 28,MP-ID Empfänger,SG2,NAD,,00011,,,,Muss, + 29,MP-ID Empfänger,SG2,NAD,3035,00011,MR,,Nachrichtenempfänger,X, + 30,MP-ID Empfänger,SG2,NAD,3039,00011,,,MP-ID,X, + 31,MP-ID Empfänger,SG2,NAD,3055,00011,9,,GS1,X, + 32,MP-ID Empfänger,SG2,NAD,3055,,332,,"DE, DVGW Service &Consult GmbH",X, + 33,Vorgang,SG4,,,,,,,Muss, + 34,Vorgang,SG4,IDE,,00012,,,,Muss, + 35,Vorgang,SG4,IDE,7495,00012,24,,Transaktion,X, + 36,Vorgang,SG4,IDE,7402,00012,,,Vorgangsnummer,X, + 37,Beginn zum,SG4,DTM,,00015,,,,Muss, + 38,Beginn zum,SG4,DTM,2005,00015,92,,Datum Vertragsbeginn,X, + 39,Beginn zum,SG4,DTM,2380,00015,,,"Datum oder Uhrzeit oderZeitspanne, Wert",X [UB2], + 40,Beginn zum,SG4,DTM,2379,00015,303,,CCYYMMDDHHMMZZZ,X, + 41,Ende zum,SG4,DTM,,00016,,,,Muss [10],[10] Wenn SG4 STS+Z17 (Transaktionsgrund für befristete Anmeldung) vorhanden + 42,Ende zum,SG4,DTM,2005,00016,93,,Datum Vertragsende,X, + 43,Ende zum,SG4,DTM,2380,00016,,,"Datum oder Uhrzeit oderZeitspanne, Wert",X [UB2], + 44,Ende zum,SG4,DTM,2379,00016,303,,CCYYMMDDHHMMZZZ,X, + 45,Bilanzierungsbeginn,SG4,DTM,,00020,,,,,"[18] Wenn SG4 DTM+93 (Ende zum) nicht vorhanden + [28] Wenn SG4 DTM+93 (Ende zum) vorhanden + [29] Wenn eine Bilanzierung stattfindet" + 46,Bilanzierungsbeginn,SG4,DTM,2005,00020,158,,Bilanzierungsbeginn,, + 47,Bilanzierungsbeginn,SG4,DTM,2380,00020,,,"Datum oder Uhrzeit oderZeitspanne, Wert",, + 48,Bilanzierungsbeginn,SG4,DTM,2379,00020,303,,CCYYMMDDHHMMZZZ,, + 49,Bilanzierungsende,SG4,DTM,,00021,,,,,"[28] Wenn SG4 DTM+93 (Ende zum) vorhanden + [64] Wenn SG4 DTM+158 (Bilanzierungsbeginn) vorhanden" + 50,Bilanzierungsende,SG4,DTM,2005,00021,159,,Bilanzierungsende,, + 51,Bilanzierungsende,SG4,DTM,2380,00021,,,"Datum oder Uhrzeit oderZeitspanne, Wert",, + 52,Bilanzierungsende,SG4,DTM,2379,00021,303,,CCYYMMDDHHMMZZZ,, + 53,Lieferbeginndatum in Bearbeitung,SG4,DTM,,00024,,,,,[36] Wenn SG4 STS+E01++ZC5 (Status der Antwort: Ablehnung andere Anmeldung in Bearbeitung) vorhanden + 54,Lieferbeginndatum in Bearbeitung,SG4,DTM,2005,00024,Z07,,Lieferbeginndatum inBearbeitung,, + 55,Lieferbeginndatum in Bearbeitung,SG4,DTM,2380,00024,,,"Datum oder Uhrzeit oderZeitspanne, Wert",, + 56,Lieferbeginndatum in Bearbeitung,SG4,DTM,2379,00024,303,,CCYYMMDDHHMMZZZ,, + 57,Datum für nächste Bearbeitung,SG4,DTM,,00025,,,,,[36] Wenn SG4 STS+E01++ZC5 (Status der Antwort: Ablehnung andere Anmeldung in Bearbeitung) vorhanden + 58,Datum für nächste Bearbeitung,SG4,DTM,2005,00025,Z08,,Datum für nächsteBearbeitung,, + 59,Datum für nächste Bearbeitung,SG4,DTM,2380,00025,,,"Datum oder Uhrzeit oderZeitspanne, Wert",, + 60,Datum für nächste Bearbeitung,SG4,DTM,2379,00025,303,,CCYYMMDDHHMMZZZ,, + 61,Transaktionsgrund,SG4,STS,,00026,,,,Muss [2061],[2061] Segment bzw. Segmentgruppe ist genau einmal je SG4 IDE (Vorgang) anzugeben + 62,Transaktionsgrund,SG4,STS,9015,00026,7,,Transaktionsgrund,X, + 63,Transaktionsgrund,SG4,STS,9013,00026,E01,,Ein-/Auszug (Umzug),X, + 64,Transaktionsgrund,SG4,STS,9013,,E02,,Einzug in Neuanlage,X, + 65,Transaktionsgrund,SG4,STS,9013,,E03,,Wechsel,X, + 66,Transaktionsgrund,SG4,STS,9013,,ZD2,,Lieferbeginn und, beiAbmeldung aus derErsatzversorgungDrittlieferant wird keine, + 67,Transaktionsgrundergänzun g für Lieferende bei befristeter Anmeldung,SG4,STS,,00027,,,,Soll [37],[37] Wenn Anmeldung/ Änderung befristet + 68,Transaktionsgrundergänzun g für Lieferende bei befristeter Anmeldung,SG4,STS,9015,00027,Z17,,Transaktionsgrundergänzung für befristeteAnmeldung,X, + 69,Transaktionsgrundergänzun g für Lieferende bei befristeter Anmeldung,SG4,STS,9013,00027,E01,,Ein-/Auszug (Umzug),X, + 70,Transaktionsgrundergänzun g für Lieferende bei befristeter Anmeldung,SG4,STS,9013,,E03,,Wechsel,X, + 71,Status der Antwort,SG4,STS,,00028,,,,,[249] Innerhalb eines SG4 IDE müssen alle DE1131 der SG4 STS+E01 den identischen Wert enthalten + 72,Status der Antwort,SG4,STS,9015,00028,E01,,Status der Antwort,, + 73,Status der Antwort,SG4,STS,9013,00028,,,Code des Prüfschritts,, + 74,Status der Antwort,SG4,STS,1131,00028,G_0011,,Codeliste Gas Nr.G_0011,, + 75,Status der Antwort,SG4,STS,1131,,G_0012,,Codeliste Gas Nr.G_0012,, + 76,Status der Antwort des dritten Marktbeteiligten,SG4,STS,,00029,,,,,[84] Wenn SG4 STS+E01++Z35 (Status der Antwort: Ablehnung der Abmeldeanfrage) vorhanden + 77,Status der Antwort des dritten Marktbeteiligten,SG4,STS,9015,00029,Z35,,Status der Antwort desdritten Marktbeteiligten,, + 78,Status der Antwort des dritten Marktbeteiligten,SG4,STS,9013,00029,,,Code des Prüfschritts,,[368] Es sind alle Codes aus der Codeliste G_0009 erlaubt + 79,Status der Antwort des dritten Marktbeteiligten,SG4,STS,1131,00029,G_0009,,Codeliste Gas Nr.G_0009,, + 80,Bemerkung (Feld für allgemeine Hinweise),SG4,FTX,,00031,,,,Kann,[48] Wenn in dieser SG4 das STS+E01++E14 + 81,Bemerkung (Feld für allgemeine Hinweise),SG4,FTX,4451,00031,ACB,,ZusätzlicheInformationen (fürallgemeine Hinweise),X, + 82,Bemerkung (Feld für allgemeine Hinweise),SG4,FTX,4440,00031,,,Text für allgemeine Information,X, + 83,Information zum Zählerstand,SG4,FTX,,00033,,,,Soll [39] ∧[51],"[39] Wenn LF beabsichtigt Zählerstand zu übermitteln + [51] Bei rückwirkendem Lieferende/Lieferbeginn" + 84,Information zum Zählerstand,SG4,FTX,4451,00033,ADM,,Information zumZählerstand,X, + 85,Information zum Zählerstand,SG4,FTX,4441,00033,Z01,,"Ankündigung, dass perMSCONS noch derZählerstand übermitteltwird",X, + 86,Meldepunkt,SG5,,,,,,,Soll [165] ∧(([2061] ∧[583]) ∨[584]),"[165] Wenn bekannt + [362] Wenn STS+E01++A03/ A17 nicht vorhanden + [527] Hinweis: Es ist die ID der Marktlokation und alle Identifikatoren der Messlokationen anzugeben + [583] Hinweis: Verwendung der ID der Marktlokation + [584] Hinweis: Verwendung der ID der Messlokation + [2061] Segment bzw. Segmentgruppe ist genau einmal je SG4 IDE (Vorgang) anzugeben" + 87,Meldepunkt,SG5,LOC,,00035,,,,Muss, + 88,Meldepunkt,SG5,LOC,3227,00035,172,,Meldepunkt,X, + 89,Meldepunkt,SG5,LOC,3225,00035,,,Identifikator,X [953],"[950] Format: Marktlokations-ID + [953] Format: Marktlokations-ID oder Zählpunktbezeichnung" + 90,Prüfidentifikator,SG6,,,,,,,Muss, + 91,Prüfidentifikator,SG6,RFF,,00037,,,,Muss, + 92,Prüfidentifikator,SG6,RFF,1153,00037,Z13,,Prüfidentifikator,X, + 93,Prüfidentifikator,SG6,RFF,1154,00037,44001,,GeLi Gas / AnmeldungNN,X, + 94,Prüfidentifikator,SG6,RFF,1154,,44002,,GeLi Gas / BestätigungAnmeldung,, + 95,Prüfidentifikator,SG6,RFF,1154,,44003,,GeLi Gas / AblehnungAnmeldung,, + 96,Referenz Vorgangsnummer (aus Anfragenachricht),SG6,,,,,,,, + 97,Referenz Vorgangsnummer (aus Anfragenachricht),SG6,RFF,,00038,,,,, + 98,Referenz Vorgangsnummer (aus Anfragenachricht),SG6,RFF,1153,00038,TN,,Transaktions-Referenznummer,, + 99,Referenz Vorgangsnummer (aus Anfragenachricht),SG6,RFF,1154,00038,,,Vorgangsnummer,, + 100,Referenz auf die ID der Marktlokation für Termine der Marktlokation,SG6,,,,,,,Muss, + 101,Referenz auf die ID der Marktlokation für Termine der Marktlokation,SG6,RFF,,00041,,,,Muss [636],[636] Hinweis: Dieses RFF klassifiziert mit einem Code im DE1153 die in derselben Segmentgruppe enthaltenen DTM zu einem Markt- bzw. Messlokation relevanten Inhalt + 102,Referenz auf die ID der Marktlokation für Termine der Marktlokation,SG6,RFF,1153,00041,Z18,,Marktlokation,X, + 103,Referenz auf die ID der Marktlokation für Termine der Marktlokation,SG6,RFF,1154,00041,,,ID der Marktlokation,,[950] Format: Marktlokations-ID + 104,Start des Abrechnungsjahrs bei Marktlokationen mit Jahresleistungspreis,SG6,DTM,,00042,,,,,[19] Wenn SG8 SEQ+Z01 (Daten der Marktlokation) SG10 CCI+++ZC0 (Prognose auf Basis von Werten) vorhanden + 105,Start des Abrechnungsjahrs bei Marktlokationen mit Jahresleistungspreis,SG6,DTM,2005,00042,155,,"Rechnungsperiode,Beginndatum",, + 106,Start des Abrechnungsjahrs bei Marktlokationen mit Jahresleistungspreis,SG6,DTM,2380,00042,,,"Datum oder Uhrzeit oderZeitspanne, Wert",, + 107,Start des Abrechnungsjahrs bei Marktlokationen mit Jahresleistungspreis,SG6,DTM,2379,00042,303,,CCYYMMDDHHMMZZZ,, + 108,Abrechnungsintervall des LF,SG6,DTM,,00043,,,,Muss, + 109,Abrechnungsintervall des LF,SG6,DTM,2005,00043,Z20,,Abrechnungsintervall des,X, + 110,Abrechnungsintervall des LF,SG6,DTM,2380,00043,,,"Datum oder Uhrzeit oderZeitspanne, Wert",X, + 111,Abrechnungsintervall des LF,SG6,DTM,2379,00043,802,,Monat,X, + 112,Termin der Netznutzungsabrechnung,SG6,DTM,,00044,,,,, + 113,Termin der Netznutzungsabrechnung,SG6,DTM,2005,00044,Z21,,Termin derNetznutzungsabrechnung,, + 114,Termin der Netznutzungsabrechnung,SG6,DTM,2380,00044,,,"Datum oder Uhrzeit oderZeitspanne, Wert",, + 115,Termin der Netznutzungsabrechnung,SG6,DTM,2379,00044,106,,MMDD,, + 116,Termin der Netznutzungsabrechnung,SG6,DTM,2379,,104,,MMWW-MMWW,, + 117,Nächste Netznutzungsabrechnung,SG6,DTM,,00045,,,,,[230] Sich ergebendes Datum/ bzw. Endedatum des Turnuszeitraums aus DTM+Z21 (Termin der Netznutzungsabrechnun g) und DTM+Z09 (Nächste Netznutzungsabrechnun g) muss >= DTM+92 (Beginn zum) sein + 118,Nächste Netznutzungsabrechnung,SG6,DTM,2005,00045,Z09,,NächsteNetznutzungsabrechnung,, + 119,Nächste Netznutzungsabrechnung,SG6,DTM,2380,00045,,,"Datum oder Uhrzeit oderZeitspanne, Wert",, + 120,Nächste Netznutzungsabrechnung,SG6,DTM,2379,00045,602,,CCYY,, + 121,Netznutzungsabrechnungsi ntervall des NB,SG6,DTM,,00046,,,,, + 122,Netznutzungsabrechnungsi ntervall des NB,SG6,DTM,2005,00046,Z22,,Netznutzungsabrechnungs- bzw.Einspeisevergütungsintervall des NB,,[504] Hinweis: Der Code Z22 wird auch in der Sparte Strom genutzt. Der Verweis auf den Einspeisevergütungsinter vall ist in der Sparte Gas nicht relevant. + 123,Netznutzungsabrechnungsi ntervall des NB,SG6,DTM,2380,00046,,,"Datum oder Uhrzeit oderZeitspanne, Wert",, + 124,Netznutzungsabrechnungsi ntervall des NB,SG6,DTM,2379,00046,802,,Monat,, + 125,Daten der Marktlokation,SG8,,,,,,,Muss, + 126,Daten der Marktlokation,SG8,SEQ,,00049,,,,Muss, + 127,Daten der Marktlokation,SG8,SEQ,1229,00049,Z01,,Daten der Marktlokation,X, + 128,Veranschlagte Jahresmenge gesamt,SG9,,,,,,,Kann,"[106] Wenn in dieser SG8 SEQ+Z01 SG10 CCI+++ZA6 (Prognosegrundlage der Marktlokation: Prognose auf Basis von Profilen) vorhanden + [513] Hinweis: Ist SG9 QTY+Y02 (TUM Kundenwert) vorhanden, dann ist ausschließlich SG9 QTY+Y02, unabhängig von SG9 QTY+31 (Veranschlagte Jahresmenge gesamt), für die Bilanzierung und MMM-Abrechnung zu nutzen" + 129,Veranschlagte Jahresmenge gesamt,SG9,QTY,,00050,,,,Muss, + 130,Veranschlagte Jahresmenge gesamt,SG9,QTY,6063,00050,31,,VeranschlagteJahresmenge Gesamt,X, + 131,Veranschlagte Jahresmenge gesamt,SG9,QTY,6060,00050,,,Mengenangabe,X [902] ∧[937],"[902] Format: Möglicher Wert: ≥ 0 + [937] Format: keine Nachkommastelle" + 132,Veranschlagte Jahresmenge gesamt,SG9,QTY,6411,00050,KWH,,Kilowattstunde,X, + 133,TUM Kundenwert,SG9,,,,,,,Kann,"[46] Wenn in SG8 SEQ+Z35 ein SG10 CCI+Z12 (Lastprofil) CAV (Lastprofil) DE3055 der Wert 293 enthalten ist + [47] Wenn in SG8 SEQ+Z35 ein SG10 CCI+Z12 (Lastprofil) CAV (Lastprofil) DE3055 der Wert 293 nicht enthalten ist + [106] Wenn in dieser SG8 SEQ+Z01 SG10 CCI+++ZA6 (Prognosegrundlage der Marktlokation: Prognose auf Basis von Profilen) vorhanden + [108] Wenn Kundenwertverfahren (z. B. TU München)" + 134,TUM Kundenwert,SG9,QTY,,00051,,,,Muss, + 135,TUM Kundenwert,SG9,QTY,6063,00051,Y02,,Kundenwert,X, + 136,TUM Kundenwert,SG9,QTY,6060,00051,,,Mengenangabe,X [902] ∧[907],"[902] Format: Möglicher Wert: ≥ 0 + [907] Format: max. 4 Nachkommastellen" + 137,TUM Kundenwert,SG9,QTY,6411,00051,KWH,,Kilowattstunde,X, + 138,Bilanzkreis,SG10,,,,,,,Muss,"[64] Wenn SG4 DTM+158 (Bilanzierungsbeginn) vorhanden + [2061] Segment bzw. Segmentgruppe ist genau einmal je SG4 IDE (Vorgang) anzugeben" + 139,Bilanzkreis,SG10,CCI,,00053,,,,Muss, + 140,Bilanzkreis,SG10,CCI,7059,00053,Z19,,Bilanzkreis,X, + 141,Bilanzkreis,SG10,CCI,7037,00053,,,Bilanzkreis,X, + 142,Angabe der Priorisierung für GeLi Gas,SG10,CAV,,00054,,,,Muss [66],[66] Wenn SG10 CCI+Z19 (Bilanzkreis) im Vorgang mehr als einmal vorhanden + 143,Angabe der Priorisierung für GeLi Gas,SG10,CAV,7111,00054,Z75,,1. Priorität,X [66], + 144,Angabe der Priorisierung für GeLi Gas,SG10,CAV,7111,,Z76,,2. Priorität,X [66], + 145,Angabe der Priorisierung für GeLi Gas,SG10,CAV,7111,,Z77,,3. Priorität,X [68], + 146,Angabe der Priorisierung für GeLi Gas,SG10,CAV,7111,,Z78,,4. Priorität,X [69], + 147,Angabe der Priorisierung für GeLi Gas,SG10,CAV,7111,,Z79,,5. Priorität,X [70],"[66] Wenn SG10 CCI+Z19 (Bilanzkreis) im Vorgang mehr als einmal vorhanden + [68] Wenn SG10 CCI+Z19 (Bilanzkreis) im Vorgang mehr als zweimal vorhanden + [69] Wenn SG10 CCI+Z19 (Bilanzkreis) im Vorgang mehr als dreimal vorhanden + [70] Wenn SG10 CCI+Z19 (Bilanzkreis) im Vorgang fünfmal vorhanden" + 148,Marktgebiet,SG10,,,,,,,, + 149,Marktgebiet,SG10,CCI,,00055,,,,, + 150,Marktgebiet,SG10,CCI,7059,00055,Z21,,Marktgebiet,, + 151,Marktgebiet,SG10,CCI,7037,00055,,,Marktgebiet,, + 152,Druckebene der Marktlokation,SG10,,,,,,,, + 153,Druckebene der Marktlokation,SG10,CCI,,00056,,,,, + 154,Druckebene der Marktlokation,SG10,CCI,7037,00056,Y01,,Druckebene derMarktlokation,, + 155,Druckebene der Marktlokation,SG10,CAV,,00057,,,,, + 156,Druckebene der Marktlokation,SG10,CAV,7111,00057,Y01,,Hochdruck,, + 157,Druckebene der Marktlokation,SG10,CAV,7111,,Y02,,Mitteldruck,, + 158,Druckebene der Marktlokation,SG10,CAV,7111,,Y03,,Niederdruck,, + 159,Prognosegrundlage der Marktlokation,SG10,,,,,,,, + 160,Prognosegrundlage der Marktlokation,SG10,CCI,,00058,,,,, + 161,Prognosegrundlage der Marktlokation,SG10,CCI,7037,00058,ZC0,,Prognose auf Basis vonWerten,, + 162,Prognosegrundlage der Marktlokation,SG10,CCI,7037,,ZA6,,Prognose auf Basis vonProfilen,, + 163,Gruppenzuordnung (nach EnWG) ,SG10,,,,,,,Muss, + 164,Gruppenzuordnung (nach EnWG) ,SG10,CCI,,00060,,,,Muss, + 165,Gruppenzuordnung (nach EnWG) ,SG10,CCI,7037,00060,Z15,,Haushaltskunde gem.EnWG,X, + 166,Gruppenzuordnung (nach EnWG) ,SG10,CCI,7037,,Z18,,Kein Haushaltskundegem. EnWG,X, + 167,Fallgruppenzuordnung,SG10,,,,,,,Kann,[19] Wenn SG8 SEQ+Z01 (Daten der Marktlokation) SG10 CCI+++ZC0 (Prognose auf Basis von Werten) vorhanden + 168,Fallgruppenzuordnung,SG10,CCI,,00061,,,,Muss, + 169,Fallgruppenzuordnung,SG10,CCI,7037,00061,Z17,,Fallgruppenzuordnungnach GABi Gas,X, + 170,Fallgruppenzuordnung,SG10,CCI,1131,00061,GABi-,,Nominierungsersatzverfa,X, + 171,Fallgruppenzuordnung,SG10,CCI,1131,,RLMNE,,hren - Exit (Hinweis:,, + 172,Fallgruppenzuordnung,SG10,CCI,1131,,V,,Dieser Code darf nur fürLiefermonate vor dem01.10.2016 genutztwerden),, + 173,Fallgruppenzuordnung,SG10,CCI,1131,,GABi-RLMmT,,RLM-Kunde inTagesregime - Exit,X, + 174,Fallgruppenzuordnung,SG10,CCI,1131,,GABi-RLMoT,,RLM-Kunde imStundenregime - Exit,X, + 175,Netznutzung,SG10,,,,,,,Muss, + 176,Netznutzung,SG10,CCI,,00062,,,,Muss, + 177,Netznutzung,SG10,CCI,7037,00062,Z88,,Netznutzung,X, + 178,Netznutzungsvertrag,SG10,CAV,,00063,,,,Muss, + 179,Netznutzungsvertrag,SG10,CAV,7111,00063,Z74,,Netznutzungsvertrag,X, + 180,Netznutzungsvertrag,SG10,CAV,7110,00063,Z08,,Direkter Vertragzwischen Kunden und NB,X, + 181,Netznutzungsvertrag,SG10,CAV,7110,,Z09,,Vertrag zwischenLieferanten und NB,X, + 182,Zahlung der Netznutzung,SG10,CAV,,00064,,,,Muss, + 183,Zahlung der Netznutzung,SG10,CAV,7111,00064,Z73,,Zahlung der Netznutzung,X, + 184,Zahlung der Netznutzung,SG10,CAV,7110,00064,Z10,,Kunde,X [216], + 185,Zahlung der Netznutzung,SG10,CAV,7110,,Z11,,Lieferant,X,[216] Wenn CCI+++Z88 (Netznutzung) CAV+Z74:::Z08 (Netznutzungsvertrag: Direkter Vertrag zwischen Kunden und NB) vorhanden + 186,Netznutzungsabrechnungsv ariante,SG10,CAV,,00065,,,,, + 187,Netznutzungsabrechnungsv ariante,SG10,CAV,7111,00065,ZB1,,Netznutzungsabrechnungsvariante,, + 188,Netznutzungsabrechnungsv ariante,SG10,CAV,7110,00065,Z14,,Arbeitspreis/Grundpreis,, + 189,Netznutzungsabrechnungsv ariante,SG10,CAV,7110,,Z15,,Arbeitspreis/Leistungspreis,, + 190,OBIS-Daten der Marktlokation,SG8,,,,,,,, + 191,OBIS-Daten der Marktlokation,SG8,SEQ,,00067,,,,, + 192,OBIS-Daten der Marktlokation,SG8,SEQ,1229,00067,Z02,,OBIS-Daten derMarktlokation,, + 193,OBIS-Kennzahl der Marktlokation,SG8,PIA,,00068,,,,, + 194,OBIS-Kennzahl der Marktlokation,SG8,PIA,4347,00068,5,,Produktidentifikation,, + 195,OBIS-Kennzahl der Marktlokation,SG8,PIA,7140,00068,,,OBIS-Kennzahl der Marktlokation,,"[315] Es sind alle OBISKennzahlen gem. EDI@Energy Codeliste der OBIS-Kennzahlen und Medien für den deutschen Energiemarkt Kap. 4 anzugeben welche an der Marktlokation erforderlich sind, dabei muss der Mindestumfang aus Kap. 4.6 eingehalten werden. Der Mindestumfang der OBIS-Kennzahlen ergibt sich aus den genannten" + 196,OBIS-Kennzahl der Marktlokation,SG8,PIA,7143,00068,SRW,,OBIS-Kennzahl,, + 197,Wertegranularität,SG10,,,,,,,,[257] Wenn in derselben SG8 SEQ+Z02 (OBIS- Daten der Marktlokation) das PIA+5+7-0?:33.86.0 vorhanden + 198,Wertegranularität,SG10,CCI,,00069,,,,, + 199,Wertegranularität,SG10,CCI,7037,00069,ZE4,,Wertegranularität,, + 200,Wertegranularität,SG10,CAV,,00070,,,,, + 201,Wertegranularität,SG10,CAV,7111,00070,ZD9,,Jährlich,, + 202,Wertegranularität,SG10,CAV,7111,,ZE8,,Halbjährlich,, + 203,Wertegranularität,SG10,CAV,7111,,ZE9,,Quartalsweise,, + 204,Wertegranularität,SG10,CAV,7111,,ZB7,,Monatlich,, + 205,Konzessionsabgabedaten,SG8,,,,,,,Soll [127],"[127] Hat der Lieferant auf Grund seines Vertrags Kenntnis, dass der Kunde keine hohe KA hat so muss er dies dem NB mitteilen + [2335] Für jede SEQ+Z02 (OBIS-Daten der Marktlokation), welche im PIA+5 die OBIS- Kennzahl 7-20:99.33.17/ 7-0:33.86.0 übermittelt, genau einmal anzugeben" + 206,Konzessionsabgabedaten,SG8,SEQ,,00071,,,,Muss, + 207,Konzessionsabgabedaten,SG8,SEQ,1229,00071,Z07,,Konzessionsabgabedaten,X, + 208,Referenz auf die OBIS- Kennzahl der Marktlokation,SG8,RFF,,00072,,,,, + 209,Referenz auf die OBIS- Kennzahl der Marktlokation,SG8,RFF,1153,00072,Z10,,OBIS-Kennzahl,, + 210,Referenz auf die OBIS- Kennzahl der Marktlokation,SG8,RFF,1154,00072,,,OBIS-Kennzahl,, + 211,Zuordnung Konzessionsabgabe,SG10,,,,,,,Muss, + 212,Zuordnung Konzessionsabgabe,SG10,CCI,,00073,,,,Muss, + 213,Zuordnung Konzessionsabgabe,SG10,CCI,7037,00073,Z08,,Konzessionsabgabe,X, + 214,Konzessionsabgabe,SG10,CAV,,00074,,,,Muss, + 215,Konzessionsabgabe,SG10,CAV,7111,00074,KAS,,"für allekonzessionsvertraglichenSonderregelungen, dienicht in die Systematikder KAV eingegliedertsind",X, + 216,Konzessionsabgabe,SG10,CAV,7111,,SA,,"Sondervertragskunden <1 kV nach § 2 (7) und > 1kV, Preis nach § 2 (3) (fürStrom 0,11 ct/kWh undfür Gas 0,03 ct/kWh)",X, + 217,Konzessionsabgabe,SG10,CAV,7111,,SAS,,"Kennzeichnung, dass einabweichender Preis fürSondervertragskundenvorliegt",X, + 218,Konzessionsabgabe,SG10,CAV,7111,,TA,,"Tarifkunden, für Strom §2. (2) 1b HT bzw. ET(hohe KA) und für Gas §2 (2) 2b",, + 219,Konzessionsabgabe,SG10,CAV,7111,,TAS,,"Kennzeichnung, dass einabweichender Preis fürTarifkunden vorliegt",X, + 220,Konzessionsabgabe,SG10,CAV,7111,,TK,,für Gas nach KAV § 2 (2)2a bei ausschließlicherNutzung zum KochenundWarmwassererzeugung,X, + 221,Konzessionsabgabe,SG10,CAV,7111,,TKS,,"Kennzeichnung, wennnach KAV § 2 (2) 2a einanderer Preis zuverwenden ist",X, + 222,Konzessionsabgabe,SG10,CAV,7110,00074,,,Konzessionsabgabe in Euro/kWh,Soll [912] ∧[902] [128]∧ [129] ,"[128] Wenn SG10 CAV+TAS/ TKS/ SAS/ KAS vorhanden + [129] Hat der Lieferant auf Grund seines Vertrags Kenntnis über die Höhe der Sonder-KA, so muss er diesen dem NB mitteilen + [902] Format: Möglicher Wert: ≥ 0 + [912] Format: max. 6 Nachkommastellen" + 223,Konzessionsabgabe,SG10,CAV,7110,00074,,,Gebührenkategorie derKonzessionsabgabe,Kann,[219] Wenn an Marktlokation vorhanden + 224,Gemeinderabatt,SG8,,,,,,,Muss, + 225,Gemeinderabatt,SG8,SEQ,,00075,,,,Muss, + 226,Gemeinderabatt,SG8,SEQ,1229,00075,Z12,,Gemeinderabatt,X, + 227,Gemeinderabatt,SG9,,,,,,,Muss, + 228,Gemeinderabatt,SG9,QTY,,00076,,,,Muss, + 229,Gemeinderabatt,SG9,QTY,6063,00076,Z16,,Gemeinderabatt,X, + 230,Gemeinderabatt,SG9,QTY,6060,00076,,,Menge,X [902] ∧[930] ∧[938],"[902] Format: Möglicher Wert: ≥ 0 + [930] Format: max. 2 Nachkommastellen + [938] Format: Möglicher Wert: <= 10" + 231,Gemeinderabatt,SG9,QTY,6411,00076,P1,,Prozent,X, + 232,Daten der Messlokation,SG8,,,,,,,,[2284] Für jede Messlokations-ID im SG5 LOC+172 (Meldepunkt) DE3225 genau einmal anzugeben + 233,Daten der Messlokation,SG8,SEQ,,00077,,,,, + 234,Daten der Messlokation,SG8,SEQ,1229,00077,Z18,,Daten der Messlokation,, + 235,Referenz auf die ID der Messlokation,SG8,RFF,,00078,,,,, + 236,Referenz auf die ID der Messlokation,SG8,RFF,1153,00078,Z19,,Messlokation,, + 237,Referenz auf die ID der Messlokation,SG8,RFF,1154,00078,,,ID der Messlokation,,[951] Format: Zählpunktbezeichnung + 238,Zugeordnete Marktpartner,SG10,,,,,,,, + 239,Zugeordnete Marktpartner,SG10,CCI,,00079,,,,, + 240,Zugeordnete Marktpartner,SG10,CCI,7037,00079,ZB3,,ZugeordneterMarktpartner,, + 241,Messstellenbetreiber,SG10,CAV,,00080,,,,, + 242,Messstellenbetreiber,SG10,CAV,7111,00080,Z91,,MSB,, + 243,Messstellenbetreiber,SG10,CAV,1131,00080,,,MP-ID,, + 244,Messstellenbetreiber,SG10,CAV,7110,00080,Z19,,Auf vertraglicherGrundlage gegenüberAnschlussnutzer /Anschlussnehmer,, + 245,Messstellenbetreiber,SG10,CAV,7110,,Z20,,In der Ausübung derWeiterverpflichtungdurch den gMSB,, + 246,Grundzuständiger Messstellenbetreiber,SG10,CAV,,00081,,,,, + 247,Grundzuständiger Messstellenbetreiber,SG10,CAV,7111,00081,ZF0,,gMSB,, + 248,Grundzuständiger Messstellenbetreiber,SG10,CAV,1131,00081,,,MP-ID,, + 249,Gasqualität,SG10,,,,,,,, + 250,Gasqualität,SG10,CCI,,00083,,,,, + 251,Gasqualität,SG10,CCI,7037,00083,Y02,,Gasqualität,, + 252,Gasqualität,SG10,CAV,,00084,,,,, + 253,Gasqualität,SG10,CAV,7111,00084,Y04,,H-Gas,, + 254,Gasqualität,SG10,CAV,7111,,Y05,,L-Gas,, + 255,Zähleinrichtungsdaten,SG8,,,,,,,Kann,[2286] Für jede SEQ+Z18 (Daten der Messlokation) mindestens einmal anzugeben + 256,Zähleinrichtungsdaten,SG8,SEQ,,00088,,,,Muss, + 257,Zähleinrichtungsdaten,SG8,SEQ,1229,00088,Z03,,Zähleinrichtungsdaten,X, + 258,Referenz auf die ID einer Messlokation,SG8,RFF,,00089,,,,, + 259,Referenz auf die ID einer Messlokation,SG8,RFF,1153,00089,Z19,,Messlokation,, + 260,Referenz auf die ID einer Messlokation,SG8,RFF,1154,00089,,,ID einer Messlokation,,[951] Format: Zählpunktbezeichnung + 261,Zählertyp,SG10,,,,,,,Muss, + 262,Zählertyp,SG10,CCI,,00090,,,,Muss, + 263,Zählertyp,SG10,CCI,7037,00090,E13,,Zählertyp,X, + 264,Zählertyp,SG10,CAV,,00091,,,,, + 265,Zählertyp,SG10,CAV,7111,00091,NMG,,neue MesseinrichtungGas nach MsbG,, + 266,Zählertyp,SG10,CAV,7111,,DKZ,,Drehkolbengaszähler,, + 267,Zählertyp,SG10,CAV,7111,,BGZ,,Balgengaszähler,, + 268,Zählertyp,SG10,CAV,7111,,TRZ,,Turbinenradgaszähler,, + 269,Zählertyp,SG10,CAV,7111,,UGZ,,Ultraschallgaszähler,, + 270,Zählertyp,SG10,CAV,7111,,WGZ,,Wirbelgaszähler,, + 271,Zählertyp,SG10,CAV,7111,,EHZ,,elektronischerHaushaltszähler,, + 272,Zählertyp,SG10,CAV,7111,,IVA,,Individuelle Abstimmung(Sonderausstattung),, + 273,Zählergröße,SG10,CAV,,00092,,,,, + 274,Zählergröße,SG10,CAV,7110,00092,G10,,Gaszähler G10,, + 275,Zählergröße,SG10,CAV,7110,,G100,,Gaszähler G100,, + 276,Zählergröße,SG10,CAV,7110,,G1000,,Gaszähler G1000,, + 277,Zählergröße,SG10,CAV,7110,,G10000,,Gaszähler G10000,, + 278,Zählergröße,SG10,CAV,7110,,G12500,,Gaszähler G12500,, + 279,Zählergröße,SG10,CAV,7110,,G16,,Gaszähler G16,, + 280,Identifikation / Nummer des Gerätes,SG10,CAV,,00093,,,,Muss, + 281,Identifikation / Nummer des Gerätes,SG10,CAV,7111,00093,Z30,,Gerätenummer,X, + 282,Identifikation / Nummer des Gerätes,SG10,CAV,7110,00093,,,Gerätenummer,X, + 283,Messwerterfassung an der Zähleinrichtung,SG10,,,,,,,, + 284,Messwerterfassung an der Zähleinrichtung,SG10,CCI,,00097,,,,, + 285,Messwerterfassung an der Zähleinrichtung,SG10,CCI,7037,00097,E12,,Messwerterfassung ander Zähleinrichtung,, + 286,Messwerterfassung an der Zähleinrichtung,SG10,CAV,,00098,,,,, + 287,Messwerterfassung an der Zähleinrichtung,SG10,CAV,7111,00098,AMR,,fernauslesbare Zähler,, + 288,Messwerterfassung an der Zähleinrichtung,SG10,CAV,7111,,MMR,,manuell ausgeleseneZähler,, + 289,Messdatenregistriergeräted aten,SG8,,,,,,,,[130] Wenn an Messlokation vorhanden + 290,Messdatenregistriergeräted aten,SG8,SEQ,,00099,,,,, + 291,Messdatenregistriergeräted aten,SG8,SEQ,1229,00099,Z50,,Messdatenregistriergerätedaten,, + 292,Referenz auf die ID einer Messlokation,SG8,RFF,,00100,,,,, + 293,Referenz auf die ID einer Messlokation,SG8,RFF,1153,00100,Z19,,Messlokation,, + 294,Referenz auf die ID einer Messlokation,SG8,RFF,1154,00100,,,ID einer Messlokation,,[951] Format: Zählpunktbezeichnung + 295,Messdatenregistriergerät,SG10,,,,,,,, + 296,Messdatenregistriergerät,SG10,CCI,,00101,,,,, + 297,Messdatenregistriergerät,SG10,CCI,7037,00101,E13,,Zählertyp,, + 298,Identifikation / Nummer des Gerätes,SG10,CAV,,00102,,,,, + 299,Identifikation / Nummer des Gerätes,SG10,CAV,7111,00102,Z30,,Gerätenummer,, + 300,Identifikation / Nummer des Gerätes,SG10,CAV,7110,00102,,,Gerätenummer,, + 301,Mengenumwerterdaten,SG8,,,,,,,,[130] Wenn an Messlokation vorhanden + 302,Mengenumwerterdaten,SG8,SEQ,,00104,,,,, + 303,Mengenumwerterdaten,SG8,SEQ,1229,00104,Z09,,Mengenumwerter-Daten,, + 304,Referenz auf die Gerätenummer,SG8,RFF,,00105,,,,, + 305,Referenz auf die Gerätenummer,SG8,RFF,1153,00105,MG,,Gerätenummer desZählers,, + 306,Referenz auf die Gerätenummer,SG8,RFF,1154,00105,,,Gerätenummer,, + 307,Mengenumwerter,SG10,,,,,,,, + 308,Mengenumwerter,SG10,CCI,,00106,,,,, + 309,Mengenumwerter,SG10,CCI,7037,00106,Z64,,Mengenumwerter,, + 310,Identifikation / Nummer des Gerätes,SG10,CAV,,00107,,,,, + 311,Identifikation / Nummer des Gerätes,SG10,CAV,7111,00107,Z30,,Gerätenummer,, + 312,Identifikation / Nummer des Gerätes,SG10,CAV,7110,00107,,,Gerätenummer,, + 313,Mengenumwertertyp,SG10,CAV,,00108,,,,, + 314,Mengenumwertertyp,SG10,CAV,7111,00108,DMU,,Dichtemengenumwerter,, + 315,Mengenumwertertyp,SG10,CAV,7111,,TMU,,Temperaturmengenumwerter,, + 316,Mengenumwertertyp,SG10,CAV,7111,,ZMU,,Zustandsmengenumwerter,, + 317,OBIS-Daten der Zähleinrichtung / Mengenumwerter,SG8,,,,,,,,"[2287] Für jede SEQ+Z03 (Zähleinrichtungsdaten) mindestens einmal anzugeben + [2353] Für jede SEQ+Z09 (Mengenumwerter- Daten) mindestens einmal anzugeben" + 318,OBIS-Daten der Zähleinrichtung / Mengenumwerter,SG8,SEQ,,00110,,,,, + 319,OBIS-Daten der Zähleinrichtung / Mengenumwerter,SG8,SEQ,1229,00110,Z20,,OBIS-Daten derZähleinrichtung,, + 320,Referenz auf die Gerätenummer,SG8,RFF,,00111,,,,,[655] Hinweis: Wenn ein Zähler an einen Mengenumwerter angeschlossen ist werden an dem Zähler keine OBIS-Kennzahlen angegeben Hier gibt es nur OBIS Kennzahlen vom Mengenumwerter   + 321,Referenz auf die Gerätenummer,SG8,RFF,1153,00111,MG,,Gerätenummer desZählers,, + 322,Referenz auf die Gerätenummer,SG8,RFF,1153,,Z11,,Gerätenummer desMengenumwerters,,[442] Wenn in keinem SG8+SEQ+Z09 Mengenumwerterdaten das RFF+MG (Referenz auf die Gerätenummer) der in diesem RFF DE1154 genannte Gerätenummer des Zählers vorhanden ist + 323,Referenz auf die Gerätenummer,SG8,RFF,1154,00111,,,Gerätenummer,, + 324,Referenz auf die ID einer Messlokation,SG8,RFF,,00112,,,,, + 325,Referenz auf die ID einer Messlokation,SG8,RFF,1153,00112,Z19,,Messlokation,, + 326,Referenz auf die ID einer Messlokation,SG8,RFF,1154,00112,,,ID einer Messlokation,,[951] Format: Zählpunktbezeichnung + 327,OBIS-Kennzahl der Zähleinrichtung / Mengenumwerter,SG8,PIA,,00113,,,,, + 328,OBIS-Kennzahl der Zähleinrichtung / Mengenumwerter,SG8,PIA,4347,00113,5,,Produktidentifikation,, + 329,OBIS-Kennzahl der Zähleinrichtung / Mengenumwerter,SG8,PIA,7140,00113,,,OBIS-Kennzahl derZähleinrichtung,,"[324] Es sind alle OBIS- Kennzahlen gem. EDI@Energy Codeliste der OBIS Kennzahlen Kap. 4. anzugeben welche an der Zähleinrichtung genutzt werden. Der Mindestumfang der OBIS-Kennzahlen ergibt sich aus den genannten Messprodukt-Codes dem Kap. 5.2 des Dokumentes ""Codeliste der Konfigurationen""" + 330,OBIS-Kennzahl der Zähleinrichtung / Mengenumwerter,SG8,PIA,7143,00113,SRW,,OBIS-Kennzahl,, + 331,Wertegranularität,SG10,,,,,,,,[274] Wenn in derselben SG8 SEQ+Z20 (OBIS- Daten der Zähleinrichtung / Mengenumwerter) das PIA+5+7-b?:3.0.0 / 7- b?:6.0.0 / 7-b?:3.1.0 / 7-b?:6.1.0 / 7-b?:3.2.0 / 7-b?:6.2.0 / 7-b?:13.2.0 / 7-b?:16.2.0 / 7-b?:1.0.0 / 7-b?:2.0.0 / 7-b?:4.0.0 / 7-b?:5.0.0 / 7-b?:11.2.0 / 7-b?:12.2.0 / 7-b?:14.2.0 / 7-b?:15.2.0 vorhanden + 332,Wertegranularität,SG10,CCI,,00114,,,,, + 333,Wertegranularität,SG10,CCI,7037,00114,ZE4,,Wertegranularität,, + 334,Wertegranularität,SG10,CAV,,00115,,,,, + 335,Wertegranularität,SG10,CAV,7111,00115,ZD9,,Jährlich,, + 336,Wertegranularität,SG10,CAV,7111,,ZE8,,Halbjährlich,, + 337,Wertegranularität,SG10,CAV,7111,,ZE9,,Quartalsweise,, + 338,Wertegranularität,SG10,CAV,7111,,ZB7,,Monatlich,, + 339,Vor- und Nachkommastellen des Zählwerks,SG10,,,,,,,,[274] Wenn in derselben SG8 SEQ+Z20 (OBIS- Daten der Zähleinrichtung / Mengenumwerter) das PIA+5+7-b?:3.0.0 / 7- b?:6.0.0 / 7-b?:3.1.0 / 7-b?:6.1.0 / 7-b?:3.2.0 / 7-b?:6.2.0 / 7-b?:13.2.0 / 7-b?:16.2.0 / 7-b?:1.0.0 / 7-b?:2.0.0 / 7-b?:4.0.0 / 7-b?:5.0.0 / 7-b?:11.2.0 / 7-b?:12.2.0 / 7-b?:14.2.0 / 7-b?:15.2.0 vorhanden + 340,Vor- und Nachkommastellen des Zählwerks,SG10,CCI,,00116,,,,, + 341,Vor- und Nachkommastellen des Zählwerks,SG10,CCI,7059,00116,11,,Produkt,, + 342,Vor- und Nachkommastellen des Zählwerks,SG10,CCI,7037,00116,Z33,,Vor- undNachkommastellen desZählwerkes,, + 343,Vor- und Nachkommastellen des Zählwerks,SG10,CAV,,00117,,,,, + 344,Vor- und Nachkommastellen des Zählwerks,SG10,CAV,7110,00117,,,Angabe der Vorkommastelle,, + 345,Vor- und Nachkommastellen des Zählwerks,SG10,CAV,7110,00117,,,Angabe der Nachkommastelle,, + 346,Bezeichnung des Zählwerks auf dem Gerät,SG10,,,,,,,,"[123] Wenn noch mindestens eine weitere SG8 SEQ+Z20 (OBIS- Daten der Zähleinrichtung / Mengenumwerter) mit dem SG8 RFF+MG / Z11 (Gerätenummer des Zählers / Mengenumwerters) auf die gleiche Identifikation/Nummer des Gerätes referenziert + [274] Wenn in derselben SG8 SEQ+Z20 (OBIS- Daten der Zähleinrichtung / Mengenumwerter) das PIA+5+7-b?:3.0.0 / 7- b?:6.0.0 / 7-b?:3.1.0 / 7-b?:6.1.0 / 7-b?:3.2.0 / 7-b?:6.2.0 / 7-b?:13.2.0 / 7-b?:16.2.0 / 7-b?:1.0.0 / 7-b?:2.0.0 / 7-b?:4.0.0 / 7-b?:5.0.0 / 7-b?:11.2.0 / 7-b?:12.2.0 / 7-b?:14.2.0 / 7-b?:15.2.0 vorhanden" + 347,Bezeichnung des Zählwerks auf dem Gerät,SG10,CCI,,00118,,,,, + 348,Bezeichnung des Zählwerks auf dem Gerät,SG10,CCI,7037,00118,Z63,,Lokale Kennzeichnung zuKontrollzwecken,, + 349,Bezeichnung des Zählwerks auf dem Gerät,SG10,CCI,7036,00118,,,Bezeichnung des Zählwerks aufdem Gerät,, + 350,Kommunikationseinrichtun gsdaten,SG8,,,,,,,,"[130] Wenn an Messlokation vorhanden + [2119] Je SG8 SEQ+Z13 (Smartmeter-Gateway) ist genau einmal die Segmentgruppe anzugeben" + 351,Kommunikationseinrichtun gsdaten,SG8,SEQ,,00119,,,,, + 352,Kommunikationseinrichtun gsdaten,SG8,SEQ,1229,00119,Z05,,Kommunikationseinrichtungsdaten,, + 353,Referenz auf die Gerätenummer,SG8,RFF,,00120,,,,, + 354,Referenz auf die Gerätenummer,SG8,RFF,1153,00120,MG,,Gerätenummer des,, + 355,Referenz auf die Gerätenummer,SG8,RFF,1154,00120,,,Gerätenummer,, + 356,Kommunikationseinrichtun g,SG10,,,,,,,, + 357,Kommunikationseinrichtun g,SG10,CCI,,00121,,,,, + 358,Kommunikationseinrichtun g,SG10,CCI,7037,00121,Z26,,Kommunikationseinrichtung,, + 359,Identifikation / Nummer des Gerätes,SG10,CAV,,00122,,,,, + 360,Identifikation / Nummer des Gerätes,SG10,CAV,7111,00122,Z30,,Gerätenummer,, + 361,Identifikation / Nummer des Gerätes,SG10,CAV,7110,00122,,,Gerätenummer,, + 362,Kommunikationseinrichtun gstyp,SG10,CAV,,00123,,,,, + 363,Kommunikationseinrichtun gstyp,SG10,CAV,7111,00123,GSM,,GSM/GPRS/UMTS-Kom.-Einr.,, + 364,Kommunikationseinrichtun gstyp,SG10,CAV,7111,,ETH,,Ethernet-Kom.-Einricht.LAN/WLAN,, + 365,Kommunikationseinrichtun gstyp,SG10,CAV,7111,,PLC,,PLC-Kom.-Einrichtung,, + 366,Kommunikationseinrichtun gstyp,SG10,CAV,7111,,PST,,Festnetz-Kom.-Einricht.TAE,, + 367,Kommunikationseinrichtun gstyp,SG10,CAV,7111,,DSL,,DSL-Kom.Einr.,, + 368,Kommunikationseinrichtun gstyp,SG10,CAV,7111,,LTE,,LTE-Kom.-Einr.,, + 369,Smartmeter-Gateway,SG8,,,,,,,,[130] Wenn an Messlokation vorhanden + 370,Smartmeter-Gateway,SG8,SEQ,,00124,,,,, + 371,Smartmeter-Gateway,SG8,SEQ,1229,00124,Z13,,Smartmeter-Gateway,, + 372,Smartmeter-Gateway,SG10,,,,,,,, + 373,Smartmeter-Gateway,SG10,CCI,,00125,,,,, + 374,Smartmeter-Gateway,SG10,CCI,7037,00125,Z75,,Smartmeter-Gateway,, + 375,Identifikation / Nummer des Gerätes,SG10,CAV,,00126,,,,, + 376,Identifikation / Nummer des Gerätes,SG10,CAV,7111,00126,Z30,,Gerätenummer,, + 377,Identifikation / Nummer des Gerätes,SG10,CAV,7110,00126,,,Gerätenummer,,[952] Format: Gerätenummer nach DIN 43863-5 + 378,Lastprofildaten,SG8,,,,,,,Kann,[106] Wenn in dieser SG8 SEQ+Z01 SG10 CCI+++ZA6 (Prognosegrundlage der Marktlokation: Prognose + 379,Lastprofildaten,SG8,SEQ,,00127,,,,Muss, + 380,Lastprofildaten,SG8,SEQ,1229,00127,Z35,,Lastprofildaten,X, + 381,Lastprofil,SG10,,,,,,,Muss, + 382,Lastprofil,SG10,CCI,,00128,,,,Muss, + 383,Lastprofil,SG10,CCI,7059,00128,Z12,,Lastprofil,X, + 384,Lastprofil,SG10,CCI,7037,00128,E01,,synthetisches Verfahren,X, + 385,Lastprofil,SG10,CCI,7037,,Z10,,analytisches Verfahren,X, + 386,Lastprofil,SG10,CAV,,00129,,,,Muss, + 387,Lastprofil,SG10,CAV,7111,00129,,,Code des Lastprofils,X, + 388,Lastprofil,SG10,CAV,3055,00129,89,,Vergeben vom Händler(hier Netzbetreiber),X, + 389,Lastprofil,SG10,CAV,3055,,293,,"DE, BDEW(Bundesverband derEnergie- undWasserwirtschaft e.V.)",X, + 390,Klimazone / Temperaturmessstelle,SG10,,,,,,,, + 391,Klimazone / Temperaturmessstelle,SG10,CCI,,00130,,,,, + 392,Klimazone / Temperaturmessstelle,SG10,CCI,7059,00130,Z99,,Messstelle desTagesparameters(derzeit ist nur dieTemperatur ein erlaubterTagesparameter),, + 393,Klimazone / Temperaturmessstelle,SG10,CCI,7059,,ZA0,,Klimazone desTagesparameters(derzeit istTagesparameter),, + 394,Klimazone / Temperaturmessstelle,SG10,CCI,7037,00130,,,ID Klimazone /Temperaturmessstelle,, + 395,Klimazone / Temperaturmessstelle,SG10,CCI,1131,00130,,,Dienstanbieter,,[58] Wenn in diesem CCI das DE3055 mit dem Code 293 vorhanden + 396,Klimazone / Temperaturmessstelle,SG10,CCI,3055,00130,89,,Vergeben vom Händler(hier Netzbetreiber),, + 397,Klimazone / Temperaturmessstelle,SG10,CCI,3055,,293,,"DE, BDEW(Bundesverband derEnergie- undWasserwirtschaft e.V.)",, + 398,Kunde des Lieferanten,SG12,,,,,,,Muss,[572] Hinweis: Kundenname aus Anmeldung Lieferant neu + 399,Kunde des Lieferanten,SG12,NAD,,00134,,,,Muss, + 400,Kunde des Lieferanten,SG12,NAD,3035,00134,Z09,,Kunde des LF,X, + 401,Kunde des Lieferanten,SG12,NAD,3036,00134,,,Name,X, + 402,Kunde des Lieferanten,SG12,NAD,3045,00134,Z01,,Struktur von,X, + 403,Kundennummer beim Lieferanten,SG12,RFF,,00135,,,,Kann,[147] Wenn in Anfrage vorhanden + 404,Kundennummer beim Lieferanten,SG12,RFF,1153,00135,AVC,,Kundennummer beimLieferanten,X, + 405,Kundennummer beim Lieferanten,SG12,RFF,1154,00135,,,Kundennummer beim LF,X, + 406,Kundennummer beim Altlieferant,SG12,RFF,,00136,,,,Soll [165],[165] Wenn bekannt + 407,Kundennummer beim Altlieferant,SG12,RFF,1153,00136,Z01,,Kundennummer beimAltlieferanten,X, + 408,Kundennummer beim Altlieferant,SG12,RFF,1154,00136,,,Kundennummer beim LFA,X, + 409,Korrespondenzanschrift des Kunden des Lieferanten,SG12,,,,,,,Muss [556]∧ [559],"[556] Hinweis: Wenn keine Korrespondenzanschrift des Endverbrauchers/ Kunden vorliegt, ist die Anschrift der Marktlokation zu übermitteln + [559] Hinweis: Die Korrespondenzanschrift des Endverbrauchers/ Kunden wird nicht zur Identifikation genutzt" + 410,Korrespondenzanschrift des Kunden des Lieferanten,SG12,NAD,,00137,,,,Muss, + 411,Korrespondenzanschrift des Kunden des Lieferanten,SG12,NAD,3035,00137,Z04,,Korrespondenzanschriftdes Kunden des LF,X, + 412,Korrespondenzanschrift des Kunden des Lieferanten,SG12,NAD,3036,00137,,,Name,X, + 413,Korrespondenzanschrift des Kunden des Lieferanten,SG12,NAD,3045,00137,Z01,,Struktur vonPersonennamen,X, + 414,Korrespondenzanschrift des Kunden des Lieferanten,SG12,NAD,3045,,Z02,,Struktur derFirmenbezeichnung,X, + 415,Korrespondenzanschrift des Kunden des Lieferanten,SG12,NAD,3042,00137,,,Straße und Hausnummer oderPostfach,X, + 416,Korrespondenzanschrift des Kunden des Lieferanten,SG12,NAD,3164,00137,,,Ort,X, + 417,Korrespondenzanschrift des Kunden des Lieferanten,SG12,NAD,3251,00137,,,Postleitzahl,M [268]S [166],"[166] Wenn vorhanden + [268] Wenn der Code im DE3207 in der ""EDI@Energy Codeliste der europäischen Ländercodes"" in der Spalte ""PLZ vorhanden""" + 418,Korrespondenzanschrift des Kunden des Lieferanten,SG12,NAD,3207,00137,,,"Ländername, Code",X, + 419,Beteiligter Marktpartner MP-ID,SG12,,,,,,,,"[84] Wenn SG4 STS+E01++Z35 (Status der Antwort: Ablehnung der Abmeldeanfrage) vorhanden + [367] Wenn SG4 STS+E01++A04 vorhanden + [566] Hinweis: Altlieferant + [643] Hinweis: Nachfolgender Netzbetreiber" + 420,Beteiligter Marktpartner MP-ID,SG12,NAD,,00144,,,,, + 421,Beteiligter Marktpartner MP-ID,SG12,NAD,3035,00144,VY,,andere zugehörige Partei,, + 422,Beteiligter Marktpartner MP-ID,SG12,NAD,3039,00144,,,MP-ID,, + 423,Beteiligter Marktpartner MP-ID,SG12,NAD,3055,00144,9,,GS1,, + 424,Beteiligter Marktpartner MP-ID,SG12,NAD,3055,,332,,"DE, DVGW Service &Consult GmbH",, + 425,Marktlokationsanschrift,SG12,,,,,,,Soll [165],[165] Wenn bekannt + 426,Marktlokationsanschrift,SG12,NAD,,00145,,,,Muss, + 427,Marktlokationsanschrift,SG12,NAD,3035,00145,DP,,Lieferanschrift,X, + 428,Marktlokationsanschrift,SG12,NAD,3124,00145,,,Zusatzinformation zurIdentifizierung,K, + 429,Marktlokationsanschrift,SG12,NAD,3042,00145,,,Straße und Hausnummer oderPostfach,S [165]M [212],"[165] Wenn bekannt + [166] Wenn vorhanden + [212] Wenn im selben SG12 NAD DE3124 nicht vorhanden" + 430,Marktlokationsanschrift,SG12,NAD,3164,00145,,,Ort,X, + 431,Marktlokationsanschrift,SG12,NAD,3251,00145,,,Postleitzahl,X, + 432,Marktlokationsanschrift,SG12,NAD,3207,00145,,,"Ländername, Code",X, + 433,Name und Adresse für die Ablesekarte,SG12,,,,,,,Muss [560],[560] Hinweis: Die Angabe Name und Adresse für die Ablesekarte wird nicht zur Identifikation genutzt + 434,Name und Adresse für die Ablesekarte,SG12,NAD,,00147,,,,Muss, + 435,Name und Adresse für die Ablesekarte,SG12,NAD,3035,00147,Z05,,Name und Adresse fürdie Ablesekarte,X, + 436,Name und Adresse für die Ablesekarte,SG12,NAD,3036,00147,,,Name,X, + 437,Name und Adresse für die Ablesekarte,SG12,NAD,3045,00147,Z01,,Struktur vonPersonennamen,X, + 438,Name und Adresse für die Ablesekarte,SG12,NAD,3045,,Z02,,Struktur derFirmenbezeichnung,X, + 439,Name und Adresse für die Ablesekarte,SG12,NAD,3042,00147,,,Straße und Hausnummer oderPostfach,X, + 440,Name und Adresse für die Ablesekarte,SG12,NAD,3164,00147,,,Ort,X, + 441,Name und Adresse für die Ablesekarte,SG12,NAD,3251,00147,,,Postleitzahl,M [268]S [166],"[166] Wenn vorhanden + [268] Wenn der Code im DE3207 in der ""EDI@Energy Codeliste der europäischen Ländercodes"" in der Spalte ""PLZ vorhanden"" ein ""X"" aufgeführt ist" + 442,Name und Adresse für die Ablesekarte,SG12,NAD,3207,00147,,,"Ländername, Code",X, + 443,Referenz auf die ID einer Messlokation,SG12,RFF,,00148,,,,Kann, + 444,Referenz auf die ID einer Messlokation,SG12,RFF,1153,00148,Z19,,Messlokation,X, + 445,Referenz auf die ID einer Messlokation,SG12,RFF,1154,00148,,,ID einer Messlokation,X [951],[951] Format: Zählpunktbezeichnung + 446,Nachrichten-Endesegment,,UNT,,00149,,,,Muss, + 447,Nachrichten-Endesegment,,UNT,0074,00149,,,Anzahl der Segmente in einerNachricht,X, + 448,Nachrichten-Endesegment,,UNT,0062,00149,,,Nachrichten-Referenznummer,X, + + ''' +# --- +# name: TestCli.test_kohlrahbi_cli_with_valid_arguments[44005] + ''' + ,Segmentname,Segmentgruppe,Segment,Datenelement,Segment ID,Code,Qualifier,Beschreibung,Bedingungsausdruck,Bedingung + 0,Nachrichten-Kopfsegment,,UNH,,00003,,,,Muss, + 1,Nachrichten-Kopfsegment,,UNH,0062,00003,,,Nachrichten-Referenznummer,X, + 2,Nachrichten-Kopfsegment,,UNH,0065,00003,UTILMD,,Netzanschluss-Stammdaten,X, + 3,Nachrichten-Kopfsegment,,UNH,0052,00003,D,,Entwurfs-Version,X, + 4,Nachrichten-Kopfsegment,,UNH,0054,00003,11A,,Ausgabe 2011 - A,X, + 5,Nachrichten-Kopfsegment,,UNH,0051,00003,UN,,UN/CEFACT,X, + 6,Nachrichten-Kopfsegment,,UNH,0057,00003,Versionsnummer derzugrundeliegendenBDEW-Nachrichtenbeschreibung,,G1.0a,X, + 7,Beginn der Nachricht,,BGM,,00004,,,,Muss, + 8,Beginn der Nachricht,,BGM,1001,00004,E02,,Abmeldungen,X, + 9,Beginn der Nachricht,,BGM,1004,00004,,,Dokumentennummer,X, + 10,Nachrichtendatum,,DTM,,00005,,,,Muss, + 11,Nachrichtendatum,,DTM,2005,00005,137,,Dokumenten-/Nachrichtendatum/-zeit,X, + 12,Nachrichtendatum,,DTM,2380,00005,,,"Datum oder Uhrzeit oderZeitspanne, Wert",X [931][494],"[494] Das hier genannte Datum muss der Zeitpunkt sein, zu dem das Dokument erstellt wurde, oder ein Zeitpunkt, der davor liegt + [931] Format: ZZZ = +00" + 13,Nachrichtendatum,,DTM,2379,00005,303,,CCYYMMDDHHMMZZZ,X, + 14,MP-ID Absender,SG2,,,,,,,Muss, + 15,MP-ID Absender,SG2,NAD,,00008,,,,Muss, + 16,MP-ID Absender,SG2,NAD,3035,00008,MS,,Dokumenten-/Nachrichtenausstellerbzw. -absender,X, + 17,MP-ID Absender,SG2,NAD,3039,00008,,,MP-ID,X, + 18,MP-ID Absender,SG2,NAD,3055,00008,9,,GS1,X, + 19,MP-ID Absender,SG2,NAD,3055,,332,,"DE, DVGW Service &Consult GmbH",X, + 20,Ansprechpartner,SG3,,,,,,,Kann, + 21,Ansprechpartner,SG3,CTA,,00009,,,,Muss, + 22,Ansprechpartner,SG3,CTA,3139,00009,IC,,Informationskontakt,X, + 23,Ansprechpartner,SG3,CTA,3412,00009,,,Name vom Ansprechpartner,X, + 24,Kommunikationsverbindung,SG3,COM,,00010,,,,Muss, + 25,Kommunikationsverbindung,SG3,COM,3148,00010,,,Nummer / Adresse,X, + 26,Kommunikationsverbindung,SG3,COM,3155,00010,EM,,Elektronische Post,X [1P0..1], + 27,MP-ID Empfänger,SG2,,,,,,,Muss, + 28,MP-ID Empfänger,SG2,NAD,,00011,,,,Muss, + 29,MP-ID Empfänger,SG2,NAD,3035,00011,MR,,Nachrichtenempfänger,X, + 30,MP-ID Empfänger,SG2,NAD,3039,00011,,,MP-ID,X, + 31,MP-ID Empfänger,SG2,NAD,3055,00011,9,,GS1,X, + 32,MP-ID Empfänger,SG2,NAD,3055,,332,,"DE, DVGW Service &Consult GmbH",X, + 33,Vorgang,SG4,,,,,,,Muss, + 34,Vorgang,SG4,IDE,,00012,,,,Muss, + 35,Vorgang,SG4,IDE,7495,00012,24,,Transaktion,X, + 36,Vorgang,SG4,IDE,7402,00012,,,Vorgangsnummer,X, + 37,Beginn zum,SG4,DTM,,00015,,,,Muss [7] ∧[577],"[7] Wenn SG4 STS+7++ZG9/ZH1/ZH2 (Transaktionsgrund: Aufhebung einer zukünftigen Zuordnung wegen Auszug des Kunden / -wegen Stilllegung / -wegen aufgehobenem Vertragsverhältnis) vorhanden + [577] Hinweis: Wird mit dem ursprünglich vom NB bestätigten Beginndatum gefüllt" + 38,Beginn zum,SG4,DTM,2005,00015,92,,Datum Vertragsbeginn,X, + 39,Beginn zum,SG4,DTM,2380,00015,,,"Datum oder Uhrzeit oderZeitspanne, Wert",X [UB2], + 40,Beginn zum,SG4,DTM,2379,00015,303,,CCYYMMDDHHMMZZZ,X, + 41,Ende zum,SG4,DTM,,00016,,,,Muss [11],[11] Wenn SG4 STS+7++ZG9/ZH1/ZH2 (Transaktionsgrund: Aufhebung einer zukünftigen Zuordnung wegen Auszug des Kunden / -wegen Stilllegung / -wegen aufgehobenem Vertragsverhältnis) nicht vorhanden + 42,Ende zum,SG4,DTM,2005,00016,93,,Datum Vertragsende,X, + 43,Ende zum,SG4,DTM,2380,00016,,,"Datum oder Uhrzeit oderZeitspanne, Wert",X [UB2], + 44,Ende zum,SG4,DTM,2379,00016,303,,CCYYMMDDHHMMZZZ,X, + 45,Bilanzierungsende,SG4,DTM,,00021,,,,Soll [29],[29] Wenn eine Bilanzierung stattfindet + 46,Bilanzierungsende,SG4,DTM,2005,00021,159,,Bilanzierungsende,X, + 47,Bilanzierungsende,SG4,DTM,2380,00021,,,"Datum oder Uhrzeit oderZeitspanne, Wert",X [UB2], + 48,Bilanzierungsende,SG4,DTM,2379,00021,303,,CCYYMMDDHHMMZZZ,X, + 49,Transaktionsgrund,SG4,STS,,00026,,,,Muss [2061],[2061] Segment bzw. Segmentgruppe ist genau einmal je SG4 IDE (Vorgang) anzugeben + 50,Transaktionsgrund,SG4,STS,9015,00026,7,,Transaktionsgrund,X, + 51,Transaktionsgrund,SG4,STS,9013,00026,E01,,Ein-/Auszug (Umzug),X, + 52,Transaktionsgrund,SG4,STS,9013,,Z33,,Auszug wegen Stilllegung,X, + 53,Transaktionsgrund,SG4,STS,9013,,Z41,,Ende der ESV ohneFolgelieferung,X, + 54,Transaktionsgrund,SG4,STS,9013,,ZG9,,Aufhebung einerzukünftigen Zuordnungwegen Auszug desKunden,X, + 55,Transaktionsgrund,SG4,STS,9013,,ZH1,,Aufhebung einerzukünftigen Zuordnungwegen Stilllegung,X, + 56,Transaktionsgrund,SG4,STS,9013,,ZH2,,Aufhebung einerzukünftigen Zuordnungwegen aufgehobenemVertragsverhältnis,X, + 57,Transaktionsgrund,SG4,STS,9013,,ZD2,,Lieferbeginn undAbmeldung aus derErsatzversorgung,, + 58,Transaktionsgrund,SG4,STS,9013,,ZT4,,Ende wegen Kündigungdurch LF,X, + 59,Transaktionsgrund,SG4,STS,9013,,ZT5,,Ende wegen Kündigungdurch Kunde/LFN,X,[510] Hinweis: Zu verwenden bei der Abmeldung der ESV + 60,Status der Antwort,SG4,STS,,00028,,,,Muss [249],[249] Innerhalb eines SG4 IDE müssen alle DE1131 der SG4 STS+E01 den identischen Wert enthalten + 61,Status der Antwort,SG4,STS,9015,00028,E01,,Status der Antwort,X, + 62,Status der Antwort,SG4,STS,9013,00028,,,Code des Prüfschritts,X, + 63,Status der Antwort,SG4,STS,1131,00028,G_0007,,Codeliste Gas Nr.G_0007,, + 64,Status der Antwort,SG4,STS,1131,,G_0008,,Codeliste Gas Nr.,X, + 65,Bemerkung (Feld für allgemeine Hinweise),SG4,FTX,,00031,,,,,[48] Wenn in dieser SG4 das STS+E01++E14 (Status der Antwort: Ablehnung Sonstiges) vorhanden + 66,Bemerkung (Feld für allgemeine Hinweise),SG4,FTX,4451,00031,ACB,,ZusätzlicheInformationen (fürallgemeine Hinweise),, + 67,Bemerkung (Feld für allgemeine Hinweise),SG4,FTX,4440,00031,,,Text für allgemeine Information,, + 68,Information zum Zählerstand,SG4,FTX,,00033,,,,,"[39] Wenn LF beabsichtigt Zählerstand zu übermitteln + [51] Bei rückwirkendem Lieferende/Lieferbeginn" + 69,Information zum Zählerstand,SG4,FTX,4451,00033,ADM,,Information zumZählerstand,, + 70,Information zum Zählerstand,SG4,FTX,4441,00033,Z01,,"Ankündigung, dass perMSCONS noch derZählerstand übermitteltwird",, + 71,Meldepunkt,SG5,,,,,,,Muss [2061]∧ [583],"[583] Hinweis: Verwendung der ID der Marktlokation + [2061] Segment bzw. Segmentgruppe ist genau einmal je SG4 IDE (Vorgang) anzugeben" + 72,Meldepunkt,SG5,LOC,,00035,,,,Muss, + 73,Meldepunkt,SG5,LOC,3227,00035,172,,Meldepunkt,X, + 74,Meldepunkt,SG5,LOC,3225,00035,,,Identifikator,X [950],[950] Format: Marktlokations-ID + 75,Prüfidentifikator,SG6,,,,,,,Muss, + 76,Prüfidentifikator,SG6,RFF,,00037,,,,Muss, + 77,Prüfidentifikator,SG6,RFF,1153,00037,Z13,,Prüfidentifikator,X, + 78,Prüfidentifikator,SG6,RFF,1154,00037,44004,,GeLi Gas / AbmeldungNN,, + 79,Prüfidentifikator,SG6,RFF,1154,,44005,,GeLi Gas / BestätigungAbmeldung,X, + 80,Prüfidentifikator,SG6,RFF,1154,,44006,,GeLi Gas / AblehnungAbmeldung,, + 81,Referenz Vorgangsnummer (aus Anfragenachricht),SG6,,,,,,,Muss, + 82,Referenz Vorgangsnummer (aus Anfragenachricht),SG6,RFF,,00038,,,,Muss, + 83,Referenz Vorgangsnummer (aus Anfragenachricht),SG6,RFF,1153,00038,TN,,Transaktions-Referenznummer,X, + 84,Referenz Vorgangsnummer (aus Anfragenachricht),SG6,RFF,1154,00038,,,Vorgangsnummer,X, + 85,Nachrichten-Endesegment,,UNT,,00149,,,,Muss, + 86,Nachrichten-Endesegment,,UNT,0074,00149,,,Anzahl der Segmente in einerNachricht,X, + 87,Nachrichten-Endesegment,,UNT,0062,00149,,,Nachrichten-Referenznummer,X, + + ''' +# --- +# name: TestCli.test_kohlrahbi_cli_with_valid_arguments[44009] + ''' + ,Segmentname,Segmentgruppe,Segment,Datenelement,Segment ID,Code,Qualifier,Beschreibung,Bedingungsausdruck,Bedingung + 0,Nachrichten-Kopfsegment,,UNH,,00003,,,,Muss, + 1,Nachrichten-Kopfsegment,,UNH,0062,00003,,,Nachrichten-Referenznummer,X, + 2,Nachrichten-Kopfsegment,,UNH,0065,00003,UTILMD,,Netzanschluss-Stammdaten,X, + 3,Nachrichten-Kopfsegment,,UNH,0052,00003,D,,Entwurfs-Version,X, + 4,Nachrichten-Kopfsegment,,UNH,0054,00003,11A,,Ausgabe 2011 - A,X, + 5,Nachrichten-Kopfsegment,,UNH,0051,00003,UN,,UN/CEFACT,X, + 6,Nachrichten-Kopfsegment,,UNH,0057,00003,Versionsnummer derzugrundeliegendenBDEW-Nachrichtenbeschreibung,,G1.0a,X, + 7,Beginn der Nachricht,,BGM,,00004,,,,Muss, + 8,Beginn der Nachricht,,BGM,1001,00004,E02,,Abmeldungen,X, + 9,Beginn der Nachricht,,BGM,1004,00004,,,Dokumentennummer,X, + 10,Nachrichtendatum,,DTM,,00005,,,,Muss, + 11,Nachrichtendatum,,DTM,2005,00005,137,,Dokumenten-/Nachrichtendatum/-zeit,X, + 12,Nachrichtendatum,,DTM,2380,00005,,,"Datum oder Uhrzeit oderZeitspanne, Wert",X [931][494],"[494] Das hier genannte Datum muss der Zeitpunkt sein, zu dem das Dokument erstellt wurde, oder ein Zeitpunkt, der davor liegt + [931] Format: ZZZ = +00" + 13,Nachrichtendatum,,DTM,2379,00005,303,,CCYYMMDDHHMMZZZ,X, + 14,MP-ID Absender,SG2,,,,,,,Muss, + 15,MP-ID Absender,SG2,NAD,,00008,,,,Muss, + 16,MP-ID Absender,SG2,NAD,3035,00008,MS,,Dokumenten-/Nachrichtenausstellerbzw. -absender,X, + 17,MP-ID Absender,SG2,NAD,3039,00008,,,MP-ID,X, + 18,MP-ID Absender,SG2,NAD,3055,00008,9,,GS1,X, + 19,MP-ID Absender,SG2,NAD,3055,,332,,"DE, DVGW Service &Consult GmbH",X, + 20,Ansprechpartner,SG3,,,,,,,Kann, + 21,Ansprechpartner,SG3,CTA,,00009,,,,Muss, + 22,Ansprechpartner,SG3,CTA,3139,00009,IC,,Informationskontakt,X, + 23,Ansprechpartner,SG3,CTA,3412,00009,,,Name vom Ansprechpartner,X, + 24,Kommunikationsverbindung,SG3,COM,,00010,,,,Muss, + 25,Kommunikationsverbindung,SG3,COM,3148,00010,,,Nummer / Adresse,X, + 26,Kommunikationsverbindung,SG3,COM,3155,00010,EM,,Elektronische Post,X [1P0..1], + 27,Kommunikationsverbindung,SG3,COM,3155,,FX,,Telefax,X [1P0..1], + 28,Kommunikationsverbindung,SG3,COM,3155,,TE,,Telefon,X [1P0..1], + 29,Kommunikationsverbindung,SG3,COM,3155,,AJ,,weiteres Telefon,X [1P0..1], + 30,Kommunikationsverbindung,SG3,COM,3155,,AL,,Handy,X [1P0..1], + 31,MP-ID Empfänger,SG2,,,,,,,Muss, + 32,MP-ID Empfänger,SG2,NAD,,00011,,,,Muss, + 33,MP-ID Empfänger,SG2,NAD,3035,00011,MR,,Nachrichtenempfänger,X, + 34,MP-ID Empfänger,SG2,NAD,3039,00011,,,MP-ID,X, + 35,MP-ID Empfänger,SG2,NAD,3055,00011,9,,GS1,X, + 36,MP-ID Empfänger,SG2,NAD,3055,,332,,"DE, DVGW Service &Consult GmbH",X, + 37,Vorgang,SG4,,,,,,,Muss, + 38,Vorgang,SG4,IDE,,00012,,,,Muss, + 39,Vorgang,SG4,IDE,7495,00012,24,,Transaktion,X, + 40,Vorgang,SG4,IDE,7402,00012,,,Vorgangsnummer,X, + 41,Ende zum,SG4,DTM,,00016,,,,, + 42,Ende zum,SG4,DTM,2005,00016,93,,Datum Vertragsende,, + 43,Ende zum,SG4,DTM,2380,00016,,,"Datum oder Uhrzeit oderZeitspanne, Wert",, + 44,Ende zum,SG4,DTM,2379,00016,303,,CCYYMMDDHHMMZZZ,, + 45,Bilanzierungsende,SG4,DTM,,00021,,,,,"[29] Wenn eine Bilanzierung stattfindet + [33] Wenn in Abmeldung ein Bilanzierungsende vorhanden" + 46,Bilanzierungsende,SG4,DTM,2005,00021,159,,Bilanzierungsende,, + 47,Bilanzierungsende,SG4,DTM,2380,00021,,,"Datum oder Uhrzeit oderZeitspanne, Wert",, + 48,Bilanzierungsende,SG4,DTM,2379,00021,303,,CCYYMMDDHHMMZZZ,, + 49,Transaktionsgrund,SG4,STS,,00026,,,,Muss [2061],[2061] Segment bzw. Segmentgruppe ist genau einmal je SG4 IDE (Vorgang) anzugeben + 50,Transaktionsgrund,SG4,STS,9015,00026,7,,Transaktionsgrund,X, + 51,Transaktionsgrund,SG4,STS,9013,00026,Z33,,Auszug wegen Stilllegung,X, + 52,Status der Antwort,SG4,STS,,00028,,,,Muss [249],[249] Innerhalb eines SG4 IDE müssen alle + 53,Status der Antwort,SG4,STS,9015,00028,E01,,Status der Antwort,X, + 54,Status der Antwort,SG4,STS,9013,00028,,,Code des Prüfschritts,X, + 55,Status der Antwort,SG4,STS,1131,00028,G_0067,,Codeliste Gas Nr.G_0067,, + 56,Status der Antwort,SG4,STS,1131,,G_0068,,Codeliste Gas Nr.G_0068,X, + 57,Bemerkung (Feld für allgemeine Hinweise),SG4,FTX,,00031,,,,Muss [48]Kann,[48] Wenn in dieser SG4 das STS+E01++E14 (Status der Antwort: Ablehnung Sonstiges) vorhanden + 58,Bemerkung (Feld für allgemeine Hinweise),SG4,FTX,4451,00031,ACB,,ZusätzlicheInformationen (fürallgemeine Hinweise),X, + 59,Bemerkung (Feld für allgemeine Hinweise),SG4,FTX,4440,00031,,,Text für allgemeine Information,X, + 60,Meldepunkt,SG5,,,,,,,Muss [2061]∧ [583] ,"[583] Hinweis: Verwendung der ID der Marktlokation + [2061] Segment bzw. Segmentgruppe ist genau einmal je SG4 IDE (Vorgang) anzugeben" + 61,Meldepunkt,SG5,LOC,,00035,,,,Muss, + 62,Meldepunkt,SG5,LOC,3227,00035,172,,Meldepunkt,X, + 63,Meldepunkt,SG5,LOC,3225,00035,,,Identifikator,X [950],[950] Format: Marktlokations-ID + 64,Prüfidentifikator,SG6,,,,,,,Muss, + 65,Prüfidentifikator,SG6,RFF,,00037,,,,Muss, + 66,Prüfidentifikator,SG6,RFF,1153,00037,Z13,,Prüfidentifikator,X, + 67,Prüfidentifikator,SG6,RFF,1154,00037,44007,,GeLi Gas / AbmeldungNN vom NB,, + 68,Prüfidentifikator,SG6,RFF,1154,,44008,,GeLi Gas / BestätigungAbmeldung vom NB,, + 69,Prüfidentifikator,SG6,RFF,1154,,44009,,GeLi Gas / AblehnungAbmeldung vom NB,X, + 70,Referenz Vorgangsnummer (aus Anfragenachricht),SG6,,,,,,,Muss, + 71,Referenz Vorgangsnummer (aus Anfragenachricht),SG6,RFF,,00038,,,,Muss, + 72,Referenz Vorgangsnummer (aus Anfragenachricht),SG6,RFF,1153,00038,TN,,Transaktions-Referenznummer,X, + 73,Referenz Vorgangsnummer (aus Anfragenachricht),SG6,RFF,1154,00038,,,Vorgangsnummer,X, + 74,Nachrichten-Endesegment,,UNT,,00149,,,,Muss, + 75,Nachrichten-Endesegment,,UNT,0074,00149,,,Anzahl der Segmente in einerNachricht,X, + 76,Nachrichten-Endesegment,,UNT,0062,00149,,,Nachrichten-Referenznummer,X, + + ''' +# --- +# name: TestCli.test_kohlrahbi_cli_with_valid_arguments[44016] + ''' + ,Segmentname,Segmentgruppe,Segment,Datenelement,Segment ID,Code,Qualifier,Beschreibung,Bedingungsausdruck,Bedingung + 0,Nachrichten-Kopfsegment,,UNH,,00003,,,,Muss, + 1,Nachrichten-Kopfsegment,,UNH,0062,00003,,,Nachrichten-Referenznummer,X, + 2,Nachrichten-Kopfsegment,,UNH,0065,00003,UTILMD,,Netzanschluss-Stammdaten,X, + 3,Nachrichten-Kopfsegment,,UNH,0052,00003,D,,Entwurfs-Version,X, + 4,Nachrichten-Kopfsegment,,UNH,0054,00003,11A,,Ausgabe 2011 - A,X, + 5,Nachrichten-Kopfsegment,,UNH,0051,00003,UN,,UN/CEFACT,X, + 6,Nachrichten-Kopfsegment,,UNH,0057,00003,Versionsnummer derzugrundeliegendenBDEW-Nachrichtenbeschreibung,,G1.0a,X, + 7,Beginn der Nachricht,,BGM,,00004,,,,Muss, + 8,Beginn der Nachricht,,BGM,1001,00004,E35,,Kündigung,X, + 9,Beginn der Nachricht,,BGM,1004,00004,,,Dokumentennummer,X, + 10,Nachrichtendatum,,DTM,,00005,,,,Muss, + 11,Nachrichtendatum,,DTM,2005,00005,137,,Dokumenten-/Nachrichtendatum/-zeit,X, + 12,Nachrichtendatum,,DTM,2380,00005,,,"Datum oder Uhrzeit oderZeitspanne, Wert",X [931][494],"[494] Das hier genannte Datum muss der Zeitpunkt sein, zu dem das Dokument erstellt wurde, oder ein Zeitpunkt, der davor liegt + [931] Format: ZZZ = +00" + 13,Nachrichtendatum,,DTM,2379,00005,303,,CCYYMMDDHHMMZZZ,X, + 14,MP-ID Absender,SG2,,,,,,,Muss, + 15,MP-ID Absender,SG2,NAD,,00008,,,,Muss, + 16,MP-ID Absender,SG2,NAD,3035,00008,MS,,Dokumenten-/Nachrichtenausstellerbzw. -absender,X, + 17,MP-ID Absender,SG2,NAD,3039,00008,,,MP-ID,X, + 18,MP-ID Absender,SG2,NAD,3055,00008,9,,GS1,X, + 19,MP-ID Absender,SG2,NAD,3055,,332,,"DE, DVGW Service &Consult GmbH",X, + 20,Ansprechpartner,SG3,,,,,,,Kann, + 21,Ansprechpartner,SG3,CTA,,00009,,,,Muss, + 22,Ansprechpartner,SG3,CTA,3139,00009,IC,,Informationskontakt,X, + 23,Ansprechpartner,SG3,CTA,3412,00009,,,Name vom Ansprechpartner,X, + 24,Kommunikationsverbindung,SG3,COM,,00010,,,,Muss, + 25,Kommunikationsverbindung,SG3,COM,3148,00010,,,Nummer / Adresse,X, + 26,Kommunikationsverbindung,SG3,COM,3155,00010,EM,,Elektronische Post,X [1P0..1], + 27,Kommunikationsverbindung,SG3,COM,3155,,FX,,Telefax,X [1P0..1], + 28,Kommunikationsverbindung,SG3,COM,3155,,TE,,Telefon,X [1P0..1], + 29,Kommunikationsverbindung,SG3,COM,3155,,AJ,,weiteres Telefon,X [1P0..1], + 30,Kommunikationsverbindung,SG3,COM,3155,,AL,,Handy,X [1P0..1], + 31,MP-ID Empfänger,SG2,,,,,,,Muss, + 32,MP-ID Empfänger,SG2,NAD,,00011,,,,Muss, + 33,MP-ID Empfänger,SG2,NAD,3035,00011,MR,,Nachrichtenempfänger,X, + 34,MP-ID Empfänger,SG2,NAD,3039,00011,,,MP-ID,X, + 35,MP-ID Empfänger,SG2,NAD,3055,00011,9,,GS1,X, + 36,MP-ID Empfänger,SG2,NAD,3055,,332,,"DE, DVGW Service &Consult GmbH",X, + 37,Vorgang,SG4,,,,,,,Muss, + 38,Vorgang,SG4,IDE,,00012,,,,Muss, + 39,Vorgang,SG4,IDE,7495,00012,24,,Transaktion,X, + 40,Vorgang,SG4,IDE,7402,00012,,,Vorgangsnummer,X, + 41,Ende zum,SG4,DTM,,00016,,,,Muss [12],"[12] Wenn SG4 DTM+471 (Ende zum nächstmöglichem Termin) nicht vorhanden + [13] Wenn SG4 STS+E01++Z01 (Status der Antwort: Zustimmung mit Terminänderung) nicht vorhanden" + 42,Ende zum,SG4,DTM,2005,00016,93,,Datum Vertragsende,X, + 43,Ende zum,SG4,DTM,2380,00016,,,"Datum oder Uhrzeit oderZeitspanne, Wert",X [UB2], + 44,Ende zum,SG4,DTM,2379,00016,303,,CCYYMMDDHHMMZZZ,X, + 45,Datum des bereits bestätigten Vertragsendes,SG4,DTM,,00017,,,,,"[15] Wenn SG4 STS+E01++Z34 (Status der Antwort: Ablehnung Mehrfachkündigung) vorhanden + [16] Wenn SG4 STS+E01++Z12 (Status der Antwort: Ablehnung Vertragsbindung) vorhanden + [17] Wenn bereits eine bestätigte Kündigung" + 46,Datum des bereits bestätigten Vertragsendes,SG4,DTM,2005,00017,Z05,,gegenüber KundebestätigtesKündigungsdatum,, + 47,Datum des bereits bestätigten Vertragsendes,SG4,DTM,2005,,Z06,,gegenüber LieferantbestätigtesKündigungsdatum,, + 48,Datum des bereits bestätigten Vertragsendes,SG4,DTM,2380,00017,,,"Datum oder Uhrzeit oderZeitspanne, Wert",, + 49,Datum des bereits bestätigten Vertragsendes,SG4,DTM,2379,00017,303,,CCYYMMDDHHMMZZZ,, + 50,"Änderung zum, Gültigkeit, Beginndatum",SG4,DTM,,00018,,,,,"[16] Wenn SG4 STS+E01++Z12 (Status der Antwort: Ablehnung Vertragsbindung) vorhanden + [581] Hinweis: Es ist das nächst mögliche Kündigungsdatum anzugeben" + 51,"Änderung zum, Gültigkeit, Beginndatum",SG4,DTM,2005,00018,157,,"Gültigkeit, Beginndatum",, + 52,"Änderung zum, Gültigkeit, Beginndatum",SG4,DTM,2380,00018,,,"Datum oder Uhrzeit oderZeitspanne, Wert",, + 53,"Änderung zum, Gültigkeit, Beginndatum",SG4,DTM,2379,00018,303,,CCYYMMDDHHMMZZZ,, + 54,Ende zum (nächstmöglichem Termin),SG4,DTM,,00019,,,,Muss [18],[18] Wenn SG4 DTM+93 (Ende zum) nicht vorhanden + 55,Ende zum (nächstmöglichem Termin),SG4,DTM,2005,00019,471,,Ende zum(nächstmöglichemTermin),X, + 56,Ende zum (nächstmöglichem Termin),SG4,DTM,2380,00019,,,"Datum oder Uhrzeit oderZeitspanne, Wert",X [UB2], + 57,Ende zum (nächstmöglichem Termin),SG4,DTM,2379,00019,303,,CCYYMMDDHHMMZZZ,X, + 58,Kündigungsfrist des Vertrags,SG4,DTM,,00022,,,,,[16] Wenn SG4 STS+E01++Z12 (Status der Antwort: Ablehnung Vertragsbindung) vorhanden + 59,Kündigungsfrist des Vertrags,SG4,DTM,2005,00022,Z01,,Kündigungsfrist,, + 60,Kündigungsfrist des Vertrags,SG4,DTM,2380,00022,,,"Datum oder Uhrzeit oderZeitspanne, Wert",, + 61,Kündigungsfrist des Vertrags,SG4,DTM,2379,00022,Z01,,ZZRB,, + 62,Kündigungstermin des Vertrags,SG4,DTM,,00023,,,,,[35] Wenn das DE2380 von SG4 DTM+Z01 (Kündigungsfrist des Vertrags) an vierter Stelle T (Termin) enthält + 63,Kündigungstermin des Vertrags,SG4,DTM,2005,00023,Z10,,Kündigungstermin,, + 64,Kündigungstermin des Vertrags,SG4,DTM,2380,00023,,,"Datum oder Uhrzeit oderZeitspanne, Wert",,[209] Wenn im selben Segment im DE2379 der Code 303 vorhanden ist + 65,Kündigungstermin des Vertrags,SG4,DTM,2379,00023,106,,MMDD,, + 66,Kündigungstermin des Vertrags,SG4,DTM,2379,,303,,CCYYMMDDHHMMZZZ,, + 67,Transaktionsgrund,SG4,STS,,00026,,,,Muss [2061],[2061] Segment bzw. Segmentgruppe ist genau einmal je SG4 IDE (Vorgang) anzugeben + 68,Transaktionsgrund,SG4,STS,9015,00026,7,,Transaktionsgrund,X, + 69,Transaktionsgrund,SG4,STS,9013,00026,E03,,Wechsel,X, + 70,Status der Antwort,SG4,STS,,00028,,,,,[249] Innerhalb eines SG4 IDE müssen alle DE1131 der SG4 STS+E01 den identischen Wert enthalten + 71,Status der Antwort,SG4,STS,9015,00028,E01,,Status der Antwort,, + 72,Status der Antwort,SG4,STS,9013,00028,,,Code des Prüfschritts,, + 73,Status der Antwort,SG4,STS,1131,00028,G_0005,,Codeliste Gas Nr.G_0005,, + 74,Status der Antwort,SG4,STS,1131,,G_0006,,Codeliste Gas Nr.G_0006,, + 75,Bemerkung (Feld für allgemeine Hinweise),SG4,FTX,,00031,,,,Kann,[48] Wenn in dieser SG4 das STS+E01++E14 (Status der Antwort: Ablehnung Sonstiges) vorhanden + 76,Bemerkung (Feld für allgemeine Hinweise),SG4,FTX,4451,00031,ACB,,ZusätzlicheInformationen (fürallgemeine Hinweise),X, + 77,Bemerkung (Feld für allgemeine Hinweise),SG4,FTX,4440,00031,,,Text für allgemeine Information,X, + 78,Meldepunkt,SG5,,,,,,,Soll [165] ∧(([2061] ∧,[165] Wenn bekannt + 79,Meldepunkt,SG5,LOC,,00035,,,,Muss, + 80,Meldepunkt,SG5,LOC,3227,00035,172,,Meldepunkt,X, + 81,Meldepunkt,SG5,LOC,3225,00035,,,Identifikator,X [953],"[950] Format: Marktlokations-ID + [953] Format: Marktlokations-ID oder Zählpunktbezeichnung" + 82,Prüfidentifikator,SG6,,,,,,,Muss, + 83,Prüfidentifikator,SG6,RFF,,00037,,,,Muss, + 84,Prüfidentifikator,SG6,RFF,1153,00037,Z13,,Prüfidentifikator,X, + 85,Prüfidentifikator,SG6,RFF,1154,00037,44016,,GeLi Gas / Kündigungbeim alten Lieferanten,X, + 86,Prüfidentifikator,SG6,RFF,1154,,44017,,GeLi Gas / BestätigungKündigung,, + 87,Prüfidentifikator,SG6,RFF,1154,,44018,,GeLi Gas / AblehnungKündigung,, + 88,Referenz Vorgangsnummer (aus Anfragenachricht),SG6,,,,,,,, + 89,Referenz Vorgangsnummer (aus Anfragenachricht),SG6,RFF,,00038,,,,, + 90,Referenz Vorgangsnummer (aus Anfragenachricht),SG6,RFF,1153,00038,TN,,Transaktions-Referenznummer,, + 91,Referenz Vorgangsnummer (aus Anfragenachricht),SG6,RFF,1154,00038,,,Vorgangsnummer,, + 92,Daten der Marktlokation,SG8,,,,,,,, + 93,Daten der Marktlokation,SG8,SEQ,,00049,,,,, + 94,Daten der Marktlokation,SG8,SEQ,1229,00049,Z01,,Daten der Marktlokation,, + 95,Vorjahresverbrauch vom Lieferant,SG9,,,,,,,, + 96,Vorjahresverbrauch vom Lieferant,SG9,QTY,,00052,,,,, + 97,Vorjahresverbrauch vom Lieferant,SG9,QTY,6063,00052,Z09,,Vorjahresverbrauch,, + 98,Vorjahresverbrauch vom Lieferant,SG9,QTY,6060,00052,,,Mengenangabe,,[902] Format: Möglicher Wert: ≥ 0 + 99,Vorjahresverbrauch vom Lieferant,SG9,QTY,6411,00052,KWH,,Kilowattstunde,, + 100,Zähleinrichtungsdaten,SG8,,,,,,,Kann, + 101,Zähleinrichtungsdaten,SG8,SEQ,,00088,,,,Muss, + 102,Zähleinrichtungsdaten,SG8,SEQ,1229,00088,Z03,,Zähleinrichtungsdaten,X, + 103,Zählertyp,SG10,,,,,,,Muss, + 104,Zählertyp,SG10,CCI,,00090,,,,Muss, + 105,Zählertyp,SG10,CCI,7037,00090,E13,,Zählertyp,X, + 106,Identifikation / Nummer des Gerätes,SG10,CAV,,00093,,,,Muss, + 107,Identifikation / Nummer des Gerätes,SG10,CAV,7111,00093,Z30,,Gerätenummer,X, + 108,Identifikation / Nummer des Gerätes,SG10,CAV,7110,00093,,,Gerätenummer,X, + 109,Kunde des Lieferanten,SG12,,,,,,,Muss, + 110,Kunde des Lieferanten,SG12,NAD,,00134,,,,Muss, + 111,Kunde des Lieferanten,SG12,NAD,3035,00134,Z09,,Kunde des LF,X, + 112,Kunde des Lieferanten,SG12,NAD,3036,00134,,,Name,X, + 113,Kunde des Lieferanten,SG12,NAD,3045,00134,Z01,,Struktur vonPersonennamen,X, + 114,Kunde des Lieferanten,SG12,NAD,3045,,Z02,,Struktur derFirmenbezeichnung,X, + 115,Kundennummer beim Altlieferant,SG12,RFF,,00136,,,,Kann, + 116,Kundennummer beim Altlieferant,SG12,RFF,1153,00136,Z01,,Kundennummer beimAltlieferanten,X, + 117,Kundennummer beim Altlieferant,SG12,RFF,1154,00136,,,Kundennummer beim LFA,X, + 118,Marktlokationsanschrift,SG12,,,,,,,Muss, + 119,Marktlokationsanschrift,SG12,NAD,,00145,,,,Muss, + 120,Marktlokationsanschrift,SG12,NAD,3035,00145,DP,,Lieferanschrift,X, + 121,Marktlokationsanschrift,SG12,NAD,3124,00145,,,Zusatzinformation zurIdentifizierung,K, + 122,Marktlokationsanschrift,SG12,NAD,3042,00145,,,Straße und Hausnummer oderPostfach,S [165]M [212],"[165] Wenn bekannt + [166] Wenn vorhanden + [212] Wenn im selben SG12 NAD DE3124 nicht vorhanden" + 123,Marktlokationsanschrift,SG12,NAD,3164,00145,,,Ort,X, + 124,Marktlokationsanschrift,SG12,NAD,3251,00145,,,Postleitzahl,X, + 125,Marktlokationsanschrift,SG12,NAD,3207,00145,,,"Ländername, Code",X, + 126,Nachrichten-Endesegment,,UNT,,00149,,,,Muss, + 127,Nachrichten-Endesegment,,UNT,0074,00149,,,Anzahl der Segmente in einerNachricht,X, + 128,Nachrichten-Endesegment,,UNT,0062,00149,,,Nachrichten-Referenznummer,X, + + ''' +# --- +# name: TestCli.test_kohlrahbi_cli_with_valid_arguments[44023] + ''' + ,Segmentname,Segmentgruppe,Segment,Datenelement,Segment ID,Code,Qualifier,Beschreibung,Bedingungsausdruck,Bedingung + 0,Nachrichten-Kopfsegment,,UNH,,00003,,,,Muss, + 1,Nachrichten-Kopfsegment,,UNH,0062,00003,,,Nachrichten-Referenznummer,X, + 2,Nachrichten-Kopfsegment,,UNH,0065,00003,UTILMD,,Netzanschluss-Stammdaten,X, + 3,Nachrichten-Kopfsegment,,UNH,0052,00003,D,,Entwurfs-Version,X, + 4,Nachrichten-Kopfsegment,,UNH,0054,00003,11A,,Ausgabe 2011 - A,X, + 5,Nachrichten-Kopfsegment,,UNH,0051,00003,UN,,UN/CEFACT,X, + 6,Nachrichten-Kopfsegment,,UNH,0057,00003,Versionsnummer derzugrundeliegendenBDEW-Nachrichtenbeschreibung,,G1.0a,X, + 7,Beginn der Nachricht,,BGM,,00004,,,,Muss [500],[500] Hinweis: Code ist gemäß der Kategorie der zu stornierenden Meldung zu wählen + 8,Beginn der Nachricht,,BGM,1001,00004,E01,,Anmeldungen,X, + 9,Beginn der Nachricht,,BGM,1001,,E02,,Abmeldungen,X, + 10,Beginn der Nachricht,,BGM,1001,,E35,,Kündigung,X, + 11,Beginn der Nachricht,,BGM,1004,00004,,,Dokumentennummer,X, + 12,Nachrichtendatum,,DTM,,00005,,,,Muss, + 13,Nachrichtendatum,,DTM,2005,00005,137,,Dokumenten-/Nachrichtendatum/-zeit,X, + 14,Nachrichtendatum,,DTM,2380,00005,,,"Datum oder Uhrzeit oderZeitspanne, Wert",X [931][494],"[494] Das hier genannte Datum muss der Zeitpunkt sein, zu dem das Dokument erstellt wurde, oder ein Zeitpunkt, der davor liegt + [931] Format: ZZZ = +00" + 15,Nachrichtendatum,,DTM,2379,00005,303,,CCYYMMDDHHMMZZZ,X, + 16,MP-ID Absender,SG2,,,,,,,Muss, + 17,MP-ID Absender,SG2,NAD,,00008,,,,Muss, + 18,MP-ID Absender,SG2,NAD,3035,00008,MS,,Dokumenten-/Nachrichtenausstellerbzw. -absender,X, + 19,MP-ID Absender,SG2,NAD,3039,00008,,,MP-ID,X, + 20,MP-ID Absender,SG2,NAD,3055,00008,9,,GS1,X, + 21,MP-ID Absender,SG2,NAD,3055,,332,,"DE, DVGW Service &Consult GmbH",X, + 22,Ansprechpartner,SG3,,,,,,,Kann, + 23,Ansprechpartner,SG3,CTA,,00009,,,,Muss, + 24,Ansprechpartner,SG3,CTA,3139,00009,IC,,Informationskontakt,X, + 25,Ansprechpartner,SG3,CTA,3412,00009,,,Name vom Ansprechpartner,X, + 26,Kommunikationsverbindung,SG3,COM,,00010,,,,Muss, + 27,Kommunikationsverbindung,SG3,COM,3148,00010,,,Nummer / Adresse,X, + 28,Kommunikationsverbindung,SG3,COM,3155,00010,EM,,Elektronische Post,X [1P0..1], + 29,Kommunikationsverbindung,SG3,COM,3155,,FX,,Telefax,X [1P0..1], + 30,Kommunikationsverbindung,SG3,COM,3155,,TE,,Telefon,X [1P0..1], + 31,Kommunikationsverbindung,SG3,COM,3155,,AJ,,weiteres Telefon,X [1P0..1], + 32,Kommunikationsverbindung,SG3,COM,3155,,AL,,Handy,X [1P0..1], + 33,MP-ID Empfänger,SG2,,,,,,,Muss, + 34,MP-ID Empfänger,SG2,NAD,,00011,,,,Muss, + 35,MP-ID Empfänger,SG2,NAD,3035,00011,MR,,Nachrichtenempfänger,X, + 36,MP-ID Empfänger,SG2,NAD,3039,00011,,,MP-ID,X, + 37,MP-ID Empfänger,SG2,NAD,3055,00011,9,,GS1,X, + 38,MP-ID Empfänger,SG2,NAD,3055,,332,,"DE, DVGW Service &Consult GmbH",X, + 39,Vorgang,SG4,,,,,,,Muss, + 40,Vorgang,SG4,IDE,,00012,,,,Muss, + 41,Vorgang,SG4,IDE,7495,00012,24,,Transaktion,X, + 42,Vorgang,SG4,IDE,7402,00012,,,Vorgangsnummer,X, + 43,Transaktionsgrund,SG4,STS,,00026,,,,Muss [2061],[2061] Segment bzw. Segmentgruppe ist genau einmal je SG4 IDE (Vorgang) anzugeben + 44,Transaktionsgrund,SG4,STS,9015,00026,7,,Transaktionsgrund,X, + 45,Transaktionsgrund,SG4,STS,9013,00026,E05,,Stornierung,X, + 46,Status der Antwort,SG4,STS,,00028,,,,Muss [249],[249] Innerhalb eines SG4 IDE müssen alle DE1131 der SG4 STS+E01 den identischen Wert enthalten + 47,Status der Antwort,SG4,STS,9015,00028,E01,,Status der Antwort,X, + 48,Status der Antwort,SG4,STS,9013,00028,,,Code des Prüfschritts,X, + 49,Status der Antwort,SG4,STS,1131,00028,G_0003,,Codeliste Gas Nr.G_0003,, + 50,Status der Antwort,SG4,STS,1131,,G_0004,,Codeliste Gas Nr.G_0004,X, + 51,Bemerkung (Feld für allgemeine Hinweise),SG4,FTX,,00031,,,,,[48] Wenn in dieser SG4 das STS+E01++E14 (Status der Antwort: Ablehnung Sonstiges) vorhanden + 52,Bemerkung (Feld für allgemeine Hinweise),SG4,FTX,4451,00031,ACB,,ZusätzlicheInformationen (fürallgemeine Hinweise),, + 53,Bemerkung (Feld für allgemeine Hinweise),SG4,FTX,4440,00031,,,Text für allgemeine Information,, + 54,Prüfidentifikator,SG6,,,,,,,Muss, + 55,Prüfidentifikator,SG6,RFF,,00037,,,,Muss, + 56,Prüfidentifikator,SG6,RFF,1153,00037,Z13,,Prüfidentifikator,X, + 57,Prüfidentifikator,SG6,RFF,1154,00037,44022,,GeLi Gas / Anfrage nachStornierung,, + 58,Prüfidentifikator,SG6,RFF,1154,,44023,,GeLi Gas / BestätigungAnfrage Stornierung,X, + 59,Prüfidentifikator,SG6,RFF,1154,,44024,,GeLi Gas / AblehnungAnfrage Stornierung,, + 60,Referenz Vorgangsnummer (aus Anfragenachricht),SG6,,,,,,,Muss, + 61,Referenz Vorgangsnummer (aus Anfragenachricht),SG6,RFF,,00038,,,,Muss, + 62,Referenz Vorgangsnummer (aus Anfragenachricht),SG6,RFF,1153,00038,TN,,Transaktions-Referenznummer,X, + 63,Referenz Vorgangsnummer (aus Anfragenachricht),SG6,RFF,1154,00038,,,Vorgangsnummer,X, + 64,Referenz auf zu stornierende Vorgangsnummer,SG6,,,,,,,, + 65,Referenz auf zu stornierende Vorgangsnummer,SG6,RFF,,00039,,,,, + 66,Referenz auf zu stornierende Vorgangsnummer,SG6,RFF,1153,00039,ACW,,Referenznummer einervorangegangenenNachricht,, + 67,Referenz auf zu stornierende Vorgangsnummer,SG6,RFF,1154,00039,,,Vorgangsnummer,, + 68,Nachrichten-Endesegment,,UNT,,00149,,,,Muss, + 69,Nachrichten-Endesegment,,UNT,0074,00149,,,Anzahl der Segmente in einerNachricht,X, + 70,Nachrichten-Endesegment,,UNT,0062,00149,,,Nachrichten-Referenznummer,X, + + ''' +# --- +# name: TestCli.test_kohlrahbi_cli_with_valid_arguments[44040] + ''' + ,Segmentname,Segmentgruppe,Segment,Datenelement,Segment ID,Code,Qualifier,Beschreibung,Bedingungsausdruck,Bedingung + 0,Nachrichten-Kopfsegment,,UNH,,00003,,,,Muss, + 1,Nachrichten-Kopfsegment,,UNH,0062,00003,,,Nachrichten-Referenznummer,X, + 2,Nachrichten-Kopfsegment,,UNH,0065,00003,UTILMD,,Netzanschluss-Stammdaten,X, + 3,Nachrichten-Kopfsegment,,UNH,0052,00003,D,,Entwurfs-Version,X, + 4,Nachrichten-Kopfsegment,,UNH,0054,00003,11A,,Ausgabe 2011 - A,X, + 5,Nachrichten-Kopfsegment,,UNH,0051,00003,UN,,UN/CEFACT,X, + 6,Nachrichten-Kopfsegment,,UNH,0057,00003,Versionsnummer derzugrundeliegendenBDEW-Nachrichtenbeschreibung,,G1.0a,X, + 7,Beginn der Nachricht,,BGM,,00004,,,,Muss, + 8,Beginn der Nachricht,,BGM,1001,00004,E35,,Kündigung,X, + 9,Beginn der Nachricht,,BGM,1004,00004,,,Dokumentennummer,X, + 10,Nachrichtendatum,,DTM,,00005,,,,Muss, + 11,Nachrichtendatum,,DTM,2005,00005,137,,Dokumenten-/Nachrichtendatum/-zeit,X, + 12,Nachrichtendatum,,DTM,2380,00005,,,"Datum oder Uhrzeit oderZeitspanne, Wert",X [931][494],"[494] Das hier genannte Datum muss der Zeitpunkt sein, zu dem das Dokument erstellt wurde, oder ein Zeitpunkt, der davor liegt + [931] Format: ZZZ = +00" + 13,Nachrichtendatum,,DTM,2379,00005,303,,CCYYMMDDHHMMZZZ,X, + 14,MP-ID Absender,SG2,,,,,,,Muss, + 15,MP-ID Absender,SG2,NAD,,00008,,,,Muss, + 16,MP-ID Absender,SG2,NAD,3035,00008,MS,,Dokumenten-/Nachrichtenausstellerbzw. -absender,X, + 17,MP-ID Absender,SG2,NAD,3039,00008,,,MP-ID,X, + 18,MP-ID Absender,SG2,NAD,3055,00008,9,,GS1,X, + 19,MP-ID Absender,SG2,NAD,3055,,332,,"DE, DVGW Service &Consult GmbH",X, + 20,Ansprechpartner,SG3,,,,,,,Kann, + 21,Ansprechpartner,SG3,CTA,,00009,,,,Muss, + 22,Ansprechpartner,SG3,CTA,3139,00009,IC,,Informationskontakt,X, + 23,Ansprechpartner,SG3,CTA,3412,00009,,,Name vom Ansprechpartner,X, + 24,Kommunikationsverbindung,SG3,COM,,00010,,,,Muss, + 25,Kommunikationsverbindung,SG3,COM,3148,00010,,,Nummer / Adresse,X, + 26,Kommunikationsverbindung,SG3,COM,3155,00010,EM,,Elektronische Post,X [1P0..1], + 27,Kommunikationsverbindung,SG3,COM,3155,,FX,,Telefax,X [1P0..1], + 28,Kommunikationsverbindung,SG3,COM,3155,,TE,,Telefon,X [1P0..1], + 29,Kommunikationsverbindung,SG3,COM,3155,,AJ,,weiteres Telefon,X [1P0..1], + 30,Kommunikationsverbindung,SG3,COM,3155,,AL,,Handy,X [1P0..1], + 31,MP-ID Empfänger,SG2,,,,,,,Muss, + 32,MP-ID Empfänger,SG2,NAD,,00011,,,,Muss, + 33,MP-ID Empfänger,SG2,NAD,3035,00011,MR,,Nachrichtenempfänger,X, + 34,MP-ID Empfänger,SG2,NAD,3039,00011,,,MP-ID,X, + 35,MP-ID Empfänger,SG2,NAD,3055,00011,9,,GS1,X, + 36,MP-ID Empfänger,SG2,NAD,3055,,332,,"DE, DVGW Service &Consult GmbH",X, + 37,Vorgang,SG4,,,,,,,Muss, + 38,Vorgang,SG4,IDE,,00012,,,,Muss, + 39,Vorgang,SG4,IDE,7495,00012,24,,Transaktion,X, + 40,Vorgang,SG4,IDE,7402,00012,,,Vorgangsnummer,X, + 41,Ende zum,SG4,DTM,,00016,,,,Muss [12] ∧[13],"[12] Wenn SG4 DTM+471 (Ende zum nächstmöglichem Termin) nicht vorhanden + [13] Wenn SG4 STS+E01++Z01 (Status der Antwort: Zustimmung mit Terminänderung) nicht vorhanden" + 42,Ende zum,SG4,DTM,2005,00016,93,,Datum Vertragsende,X, + 43,Ende zum,SG4,DTM,2380,00016,,,"Datum oder Uhrzeit oderZeitspanne, Wert",X [UB2], + 44,Ende zum,SG4,DTM,2379,00016,303,,CCYYMMDDHHMMZZZ,X, + 45,"Änderung zum, Gültigkeit, Beginndatum",SG4,DTM,,00018,,,,,"[16] Wenn SG4 STS+E01++Z12 (Status der Antwort: Ablehnung Vertragsbindung) vorhanden + [581] Hinweis: Es ist das nächst mögliche Kündigungsdatum anzugeben" + 46,"Änderung zum, Gültigkeit, Beginndatum",SG4,DTM,2005,00018,157,,"Gültigkeit, Beginndatum",, + 47,"Änderung zum, Gültigkeit, Beginndatum",SG4,DTM,2380,00018,,,Datum oder Uhrzeit oder,, + 48,"Änderung zum, Gültigkeit, Beginndatum",SG4,DTM,2379,00018,303,,CCYYMMDDHHMMZZZ,, + 49,Ende zum (nächstmöglichem Termin),SG4,DTM,,00019,,,,Muss [18],[18] Wenn SG4 DTM+93 (Ende zum) nicht vorhanden + 50,Ende zum (nächstmöglichem Termin),SG4,DTM,2005,00019,471,,Ende zum(nächstmöglichemTermin),X, + 51,Ende zum (nächstmöglichem Termin),SG4,DTM,2380,00019,,,"Datum oder Uhrzeit oderZeitspanne, Wert",X [UB2], + 52,Ende zum (nächstmöglichem Termin),SG4,DTM,2379,00019,303,,CCYYMMDDHHMMZZZ,X, + 53,Kündigungsfrist des Vertrags,SG4,DTM,,00022,,,,,[16] Wenn SG4 STS+E01++Z12 (Status der Antwort: Ablehnung Vertragsbindung) vorhanden + 54,Kündigungsfrist des Vertrags,SG4,DTM,2005,00022,Z01,,Kündigungsfrist,, + 55,Kündigungsfrist des Vertrags,SG4,DTM,2380,00022,,,"Datum oder Uhrzeit oderZeitspanne, Wert",, + 56,Kündigungsfrist des Vertrags,SG4,DTM,2379,00022,Z01,,ZZRB,, + 57,Kündigungstermin des Vertrags,SG4,DTM,,00023,,,,,[35] Wenn das DE2380 von SG4 DTM+Z01 (Kündigungsfrist des Vertrags) an vierter Stelle T (Termin) enthält + 58,Kündigungstermin des Vertrags,SG4,DTM,2005,00023,Z10,,Kündigungstermin,, + 59,Kündigungstermin des Vertrags,SG4,DTM,2380,00023,,,"Datum oder Uhrzeit oderZeitspanne, Wert",,[209] Wenn im selben Segment im DE2379 der Code 303 vorhanden ist + 60,Kündigungstermin des Vertrags,SG4,DTM,2379,00023,106,,MMDD,, + 61,Kündigungstermin des Vertrags,SG4,DTM,2379,,303,,CCYYMMDDHHMMZZZ,, + 62,Transaktionsgrund,SG4,STS,,00026,,,,Muss [2061],[2061] Segment bzw. Segmentgruppe ist genau einmal je SG4 IDE (Vorgang) anzugeben + 63,Transaktionsgrund,SG4,STS,9015,00026,7,,Transaktionsgrund,X, + 64,Transaktionsgrund,SG4,STS,9013,00026,E03,,Wechsel,X, + 65,Transaktionsgrund,SG4,STS,9013,,ZR9,,Kündigung aufgrundVertrag mit,X, + 66,Status der Antwort,SG4,STS,,00028,,,,Muss [249],[249] Innerhalb eines SG4 IDE müssen alle DE1131 der SG4 STS+E01 den identischen Wert enthalten + 67,Status der Antwort,SG4,STS,9015,00028,E01,,Status der Antwort,X, + 68,Status der Antwort,SG4,STS,9013,00028,,,Code des Prüfschritts,X, + 69,Status der Antwort,SG4,STS,1131,00028,G_0051,,Codeliste Gas Nr.G_0051,, + 70,Status der Antwort,SG4,STS,1131,,G_0052,,Codeliste Gas Nr.G_0052,X, + 71,Meldepunkt,SG5,,,,,,,Muss [2061]∧ [584],"[77] Wenn SG8 SEQ+Z03 (Zähleinrichtungsdaten) CAV+Z30 (Identifikation/Nummer des Gerätes) nicht vorhanden + [584] Hinweis: Verwendung der ID der Messlokation + [2061] Segment bzw. Segmentgruppe ist genau einmal je SG4 IDE (Vorgang) anzugeben" + 72,Meldepunkt,SG5,LOC,,00035,,,,Muss, + 73,Meldepunkt,SG5,LOC,3227,00035,172,,Meldepunkt,X, + 74,Meldepunkt,SG5,LOC,3225,00035,,,Identifikator,X [951],[951] Format: Zählpunktbezeichnung + 75,Prüfidentifikator,SG6,,,,,,,Muss, + 76,Prüfidentifikator,SG6,RFF,,00037,,,,Muss, + 77,Prüfidentifikator,SG6,RFF,1153,00037,Z13,,Prüfidentifikator,X, + 78,Prüfidentifikator,SG6,RFF,1154,00037,44039,,WiM Gas / KündigungMSB,, + 79,Prüfidentifikator,SG6,RFF,1154,,44040,,WiM Gas / BestätigungKündigung MSB,X, + 80,Prüfidentifikator,SG6,RFF,1154,,44041,,WiM Gas / AblehnungKündigung MSB,, + 81,Referenz Vorgangsnummer (aus Anfragenachricht),SG6,,,,,,,Muss, + 82,Referenz Vorgangsnummer (aus Anfragenachricht),SG6,RFF,,00038,,,,Muss, + 83,Referenz Vorgangsnummer (aus Anfragenachricht),SG6,RFF,1153,00038,TN,,Transaktions-Referenznummer,X, + 84,Referenz Vorgangsnummer (aus Anfragenachricht),SG6,RFF,1154,00038,,,Vorgangsnummer,X, + 85,Zähleinrichtungsdaten,SG8,,,,,,,Muss,[138] Wenn SG5 LOC+172 (Meldepunkt) nicht vorhanden + 86,Zähleinrichtungsdaten,SG8,SEQ,,00088,,,,Muss, + 87,Zähleinrichtungsdaten,SG8,SEQ,1229,00088,Z03,,Zähleinrichtungsdaten,X, + 88,Referenz auf die ID einer Messlokation,SG8,RFF,,00089,,,,Muss, + 89,Referenz auf die ID einer Messlokation,SG8,RFF,1153,00089,Z19,,Messlokation,X, + 90,Referenz auf die ID einer Messlokation,SG8,RFF,1154,00089,,,ID einer Messlokation,X [951],[951] Format: Zählpunktbezeichnung + 91,Zählertyp,SG10,,,,,,,Muss, + 92,Zählertyp,SG10,CCI,,00090,,,,Muss, + 93,Zählertyp,SG10,CCI,7037,00090,E13,,Zählertyp,X, + 94,Identifikation / Nummer des Gerätes,SG10,CAV,,00093,,,,Muss, + 95,Identifikation / Nummer des Gerätes,SG10,CAV,7111,00093,Z30,,Gerätenummer,X, + 96,Identifikation / Nummer des Gerätes,SG10,CAV,7110,00093,,,Gerätenummer,X, + 97,Kunde des Messstellenbetreibers,SG12,,,,,,,Muss, + 98,Kunde des Messstellenbetreibers,SG12,NAD,,00138,,,,Muss, + 99,Kunde des Messstellenbetreibers,SG12,NAD,3035,00138,Z07,,Kunde des MSB,X, + 100,Kunde des Messstellenbetreibers,SG12,NAD,3036,00138,,,Name,X, + 101,Kunde des Messstellenbetreibers,SG12,NAD,3045,00138,Z01,,Struktur vonPersonennamen,X, + 102,Kunde des Messstellenbetreibers,SG12,NAD,3045,,Z02,,Struktur derFirmenbezeichnung,X, + 103,Messlokationsadresse,SG12,,,,,,,Muss,[165] Wenn bekannt + 104,Messlokationsadresse,SG12,NAD,,00146,,,,Muss, + 105,Messlokationsadresse,SG12,NAD,3035,00146,Z03,,Messlokationsadresse,X, + 106,Messlokationsadresse,SG12,NAD,3124,00146,,,Zusatzinformation zurIdentifizierung,K, + 107,Messlokationsadresse,SG12,NAD,3042,00146,,,Straße und Hausnummer oderPostfach,S [166]M [212],"[166] Wenn vorhanden + [212] Wenn im selben SG12 NAD DE3124 nicht vorhanden" + 108,Messlokationsadresse,SG12,NAD,3164,00146,,,Ort,X, + 109,Messlokationsadresse,SG12,NAD,3251,00146,,,Postleitzahl,X, + 110,Messlokationsadresse,SG12,NAD,3207,00146,,,"Ländername, Code",X, + 111,Nachrichten-Endesegment,,UNT,,00149,,,,Muss, + 112,Nachrichten-Endesegment,,UNT,0074,00149,,,Anzahl der Segmente in einerNachricht,X, + 113,Nachrichten-Endesegment,,UNT,0062,00149,,,Nachrichten-Referenznummer,X, + + ''' +# --- +# name: TestCli.test_kohlrahbi_cli_with_valid_arguments[44053] + ''' + ,Segmentname,Segmentgruppe,Segment,Datenelement,Segment ID,Code,Qualifier,Beschreibung,Bedingungsausdruck,Bedingung + 0,Nachrichten-Kopfsegment,,UNH,,00003,,,,Muss, + 1,Nachrichten-Kopfsegment,,UNH,0062,00003,,,Nachrichten-Referenznummer,X, + 2,Nachrichten-Kopfsegment,,UNH,0065,00003,UTILMD,,Netzanschluss-Stammdaten,X, + 3,Nachrichten-Kopfsegment,,UNH,0052,00003,D,,Entwurfs-Version,X, + 4,Nachrichten-Kopfsegment,,UNH,0054,00003,11A,,Ausgabe 2011 - A,X, + 5,Nachrichten-Kopfsegment,,UNH,0051,00003,UN,,UN/CEFACT,X, + 6,Nachrichten-Kopfsegment,,UNH,0057,00003,Versionsnummer derzugrundeliegendenBDEW-Nachrichtenbeschreibung,,G1.0a,X, + 7,Beginn der Nachricht,,BGM,,00004,,,,Muss, + 8,Beginn der Nachricht,,BGM,1001,00004,E02,,Abmeldungen,X, + 9,Beginn der Nachricht,,BGM,1004,00004,,,Dokumentennummer,X, + 10,Nachrichtendatum,,DTM,,00005,,,,Muss, + 11,Nachrichtendatum,,DTM,2005,00005,137,,Dokumenten-/Nachrichtendatum/-zeit,X, + 12,Nachrichtendatum,,DTM,2380,00005,,,"Datum oder Uhrzeit oderZeitspanne, Wert",X [931][494],"[494] Das hier genannte Datum muss der Zeitpunkt sein, zu dem das Dokument erstellt wurde, oder ein Zeitpunkt, der davor liegt + [931] Format: ZZZ = +00" + 13,Nachrichtendatum,,DTM,2379,00005,303,,CCYYMMDDHHMMZZZ,X, + 14,MP-ID Absender,SG2,,,,,,,Muss, + 15,MP-ID Absender,SG2,NAD,,00008,,,,Muss, + 16,MP-ID Absender,SG2,NAD,3035,00008,MS,,Dokumenten-/Nachrichtenausstellerbzw. -absender,X, + 17,MP-ID Absender,SG2,NAD,3039,00008,,,MP-ID,X, + 18,MP-ID Absender,SG2,NAD,3055,00008,9,,GS1,X, + 19,MP-ID Absender,SG2,NAD,3055,,332,,"DE, DVGW Service &Consult GmbH",X, + 20,Ansprechpartner,SG3,,,,,,,Kann, + 21,Ansprechpartner,SG3,CTA,,00009,,,,Muss, + 22,Ansprechpartner,SG3,CTA,3139,00009,IC,,Informationskontakt,X, + 23,Ansprechpartner,SG3,CTA,3412,00009,,,Name vom Ansprechpartner,X, + 24,Kommunikationsverbindung,SG3,COM,,00010,,,,Muss, + 25,Kommunikationsverbindung,SG3,COM,3148,00010,,,Nummer / Adresse,X, + 26,Kommunikationsverbindung,SG3,COM,3155,00010,EM,,Elektronische Post,X [1P0..1], + 27,MP-ID Empfänger,SG2,,,,,,,Muss, + 28,MP-ID Empfänger,SG2,NAD,,00011,,,,Muss, + 29,MP-ID Empfänger,SG2,NAD,3035,00011,MR,,Nachrichtenempfänger,X, + 30,MP-ID Empfänger,SG2,NAD,3039,00011,,,MP-ID,X, + 31,MP-ID Empfänger,SG2,NAD,3055,00011,9,,GS1,X, + 32,MP-ID Empfänger,SG2,NAD,3055,,332,,"DE, DVGW Service &Consult GmbH",X, + 33,Vorgang,SG4,,,,,,,Muss, + 34,Vorgang,SG4,IDE,,00012,,,,Muss, + 35,Vorgang,SG4,IDE,7495,00012,24,,Transaktion,X, + 36,Vorgang,SG4,IDE,7402,00012,,,Vorgangsnummer,X, + 37,Beginn zum,SG4,DTM,,00015,,,,,"[7] Wenn SG4 STS+7++ZG9/ZH1/ZH2 (Transaktionsgrund: Aufhebung einer zukünftigen Zuordnung wegen Auszug des Kunden / -wegen Stilllegung / -wegen aufgehobenem Vertragsverhältnis) vorhanden + [577] Hinweis: Wird mit dem ursprünglich vom NB bestätigten Beginndatum gefüllt" + 38,Beginn zum,SG4,DTM,2005,00015,92,,Datum Vertragsbeginn,, + 39,Beginn zum,SG4,DTM,2380,00015,,,"Datum oder Uhrzeit oderZeitspanne, Wert",, + 40,Beginn zum,SG4,DTM,2379,00015,303,,CCYYMMDDHHMMZZZ,, + 41,Ende zum,SG4,DTM,,00016,,,,,[11] Wenn SG4 STS+7++ZG9/ZH1/ZH2 (Transaktionsgrund: Aufhebung einer zukünftigen Zuordnung wegen Auszug des Kunden / -wegen Stilllegung / -wegen aufgehobenem Vertragsverhältnis) nicht vorhanden + 42,Ende zum,SG4,DTM,2005,00016,93,,Datum Vertragsende,, + 43,Ende zum,SG4,DTM,2380,00016,,,"Datum oder Uhrzeit oderZeitspanne, Wert",, + 44,Ende zum,SG4,DTM,2379,00016,303,,CCYYMMDDHHMMZZZ,, + 45,Transaktionsgrund,SG4,STS,,00026,,,,Muss [2061],[2061] Segment bzw. Segmentgruppe ist genau einmal je SG4 IDE (Vorgang) anzugeben + 46,Transaktionsgrund,SG4,STS,9015,00026,7,,Transaktionsgrund,X, + 47,Transaktionsgrund,SG4,STS,9013,00026,E01,,Ein-/Auszug (Umzug),X, + 48,Transaktionsgrund,SG4,STS,9013,,E03,,Wechsel,X, + 49,Transaktionsgrund,SG4,STS,9013,,Z33,,Auszug wegen Stilllegung,X, + 50,Transaktionsgrund,SG4,STS,9013,,ZG9,,Aufhebung einerzukünftigen Zuordnungwegen Auszug desKunden,X, + 51,Transaktionsgrund,SG4,STS,9013,,ZH1,,Aufhebung einerzukünftigen Zuordnungwegen Stilllegung,X, + 52,Transaktionsgrund,SG4,STS,9013,,ZH2,,Aufhebung einerzukünftigen Zuordnungwegen aufgehobenemVertragsverhältnis,X, + 53,Status der Antwort,SG4,STS,,00028,,,,Muss [249],[249] Innerhalb eines SG4 IDE müssen alle DE1131 der SG4 STS+E01 den identischen Wert enthalten + 54,Status der Antwort,SG4,STS,9015,00028,E01,,Status der Antwort,X, + 55,Status der Antwort,SG4,STS,9013,00028,,,Code des Prüfschritts,X, + 56,Status der Antwort,SG4,STS,1131,00028,G_0057,,Codeliste Gas Nr.G_0057,X, + 57,Status der Antwort,SG4,STS,1131,,G_0058,,Codeliste Gas Nr.G_0058,, + 58,Meldepunkt,SG5,,,,,,,Muss [2061]∧ [584],"[584] Hinweis: Verwendung der ID der Messlokation + [2061] Segment bzw. Segmentgruppe ist genau einmal je SG4 IDE (Vorgang) anzugeben" + 59,Meldepunkt,SG5,LOC,,00035,,,,Muss, + 60,Meldepunkt,SG5,LOC,3227,00035,172,,Meldepunkt,X, + 61,Meldepunkt,SG5,LOC,3225,00035,,,Identifikator,X [951],[951] Format: Zählpunktbezeichnung + 62,Prüfidentifikator,SG6,,,,,,,Muss, + 63,Prüfidentifikator,SG6,RFF,,00037,,,,Muss, + 64,Prüfidentifikator,SG6,RFF,1153,00037,Z13,,Prüfidentifikator,X, + 65,Prüfidentifikator,SG6,RFF,1154,00037,44051,,WiM Gas / Ende MSB,, + 66,Prüfidentifikator,SG6,RFF,1154,,44052,,WiM Gas / BestätigungEnde MSB,, + 67,Prüfidentifikator,SG6,RFF,1154,,44053,,WiM Gas / AblehnungEnde MSB,X, + 68,Referenz Vorgangsnummer (aus Anfragenachricht),SG6,,,,,,,Muss, + 69,Referenz Vorgangsnummer (aus Anfragenachricht),SG6,RFF,,00038,,,,Muss, + 70,Referenz Vorgangsnummer (aus Anfragenachricht),SG6,RFF,1153,00038,TN,,Transaktions-Referenznummer,X, + 71,Referenz Vorgangsnummer (aus Anfragenachricht),SG6,RFF,1154,00038,,,Vorgangsnummer,X, + 72,Nachrichten-Endesegment,,UNT,,00149,,,,Muss, + 73,Nachrichten-Endesegment,,UNT,0074,00149,,,Anzahl der Segmente in einerNachricht,X, + 74,Nachrichten-Endesegment,,UNT,0062,00149,,,Nachrichten-Referenznummer,X, + + ''' +# --- +# name: TestCli.test_kohlrahbi_cli_with_valid_arguments[44103] + ''' + ,Segmentname,Segmentgruppe,Segment,Datenelement,Segment ID,Code,Qualifier,Beschreibung,Bedingungsausdruck,Bedingung + 0,Nachrichten-Kopfsegment,,UNH,,00003,,,,Muss, + 1,Nachrichten-Kopfsegment,,UNH,0062,00003,,,Nachrichten-Referenznummer,X, + 2,Nachrichten-Kopfsegment,,UNH,0065,00003,UTILMD,,Netzanschluss-Stammdaten,X, + 3,Nachrichten-Kopfsegment,,UNH,0052,00003,D,,Entwurfs-Version,X, + 4,Nachrichten-Kopfsegment,,UNH,0054,00003,11A,,Ausgabe 2011 - A,X, + 5,Nachrichten-Kopfsegment,,UNH,0051,00003,UN,,UN/CEFACT,X, + 6,Nachrichten-Kopfsegment,,UNH,0057,00003,Versionsnummer derzugrundeliegendenBDEW-Nachrichtenbeschreibung,,G1.0a,X, + 7,Nachrichten-Kopfsegment,,UNH,0068,00003,,,Allgemeine Zuordnungs-Referenz,S [1],[1] Wenn Aufteilung vorhanden + 8,Nachrichten-Kopfsegment,,UNH,0070,00003,,,Übermittlungsfolgenummer,X [252],[252] Wenn DE0068 vorhanden + 9,Nachrichten-Kopfsegment,,UNH,0073,00003,C,,Beginn,M [2], + 10,Nachrichten-Kopfsegment,,UNH,0073,,F,,Ende,S [3],"[2] Wenn UNH DE0070 (Übermittlungsfolgenum mer) mit 1 vorhanden + [3] Bei Aufteilung, in der Nachricht mit der höchsten Übermittlungsfolgenum mer" + 11,Beginn der Nachricht,,BGM,,00004,,,,Muss, + 12,Beginn der Nachricht,,BGM,1001,00004,Z22,,Netzbetreiberwechsel,X, + 13,Beginn der Nachricht,,BGM,1004,00004,,,Dokumentennummer,X, + 14,Nachrichtendatum,,DTM,,00005,,,,Muss, + 15,Nachrichtendatum,,DTM,2005,00005,137,,Dokumenten-/Nachrichtendatum/-zeit,X, + 16,Nachrichtendatum,,DTM,2380,00005,,,"Datum oder Uhrzeit oderZeitspanne, Wert",X [931][494],"[494] Das hier genannte Datum muss der Zeitpunkt sein, zu dem das Dokument erstellt wurde, oder ein Zeitpunkt, der davor liegt + [931] Format: ZZZ = +00" + 17,Nachrichtendatum,,DTM,2379,00005,303,,CCYYMMDDHHMMZZZ,X, + 18,MP-ID Absender,SG2,,,,,,,Muss, + 19,MP-ID Absender,SG2,NAD,,00008,,,,Muss, + 20,MP-ID Absender,SG2,NAD,3035,00008,MS,,Dokumenten-/Nachrichtenausstellerbzw. -absender,X, + 21,MP-ID Absender,SG2,NAD,3039,00008,,,MP-ID,X, + 22,MP-ID Absender,SG2,NAD,3055,00008,9,,GS1,X, + 23,MP-ID Absender,SG2,NAD,3055,,332,,"DE, DVGW Service &Consult GmbH",X, + 24,Ansprechpartner,SG3,,,,,,,Kann, + 25,Ansprechpartner,SG3,CTA,,00009,,,,Muss, + 26,Ansprechpartner,SG3,CTA,3139,00009,IC,,Informationskontakt,X, + 27,Ansprechpartner,SG3,CTA,3412,00009,,,Name vom Ansprechpartner,X, + 28,Kommunikationsverbindung,SG3,COM,,00010,,,,Muss, + 29,Kommunikationsverbindung,SG3,COM,3148,00010,,,Nummer / Adresse,X, + 30,Kommunikationsverbindung,SG3,COM,3155,00010,EM,,Elektronische Post,X [1P0..1], + 31,Kommunikationsverbindung,SG3,COM,3155,,FX,,Telefax,X [1P0..1], + 32,Kommunikationsverbindung,SG3,COM,3155,,TE,,Telefon,X [1P0..1], + 33,Kommunikationsverbindung,SG3,COM,3155,,AJ,,weiteres Telefon,X [1P0..1], + 34,Kommunikationsverbindung,SG3,COM,3155,,AL,,Handy,X [1P0..1], + 35,MP-ID Empfänger,SG2,,,,,,,Muss, + 36,MP-ID Empfänger,SG2,NAD,,00011,,,,Muss, + 37,MP-ID Empfänger,SG2,NAD,3035,00011,MR,,Nachrichtenempfänger,X, + 38,MP-ID Empfänger,SG2,NAD,3039,00011,,,MP-ID,X, + 39,MP-ID Empfänger,SG2,NAD,3055,00011,9,,GS1,X, + 40,MP-ID Empfänger,SG2,NAD,3055,,332,,"DE, DVGW Service &Consult GmbH",X, + 41,Vorgang,SG4,,,,,,,Muss, + 42,Vorgang,SG4,IDE,,00012,,,,Muss, + 43,Vorgang,SG4,IDE,7495,00012,24,,Transaktion,X, + 44,Vorgang,SG4,IDE,7402,00012,,,Vorgangsnummer,X, + 45,Beginn zum,SG4,DTM,,00015,,,,Muss [508],"[9] Wenn SG4 STS+7++ZE4 (Transaktionsgrund: Weggefallene Markt- bzw. Messlokation) nicht vorhanden + [508] Hinweis: Beginndatum beim neuen NB" + 46,Beginn zum,SG4,DTM,2005,00015,92,,Datum Vertragsbeginn,X, + 47,Beginn zum,SG4,DTM,2380,00015,,,"Datum oder Uhrzeit oderZeitspanne, Wert",X [UB2], + 48,Beginn zum,SG4,DTM,2379,00015,303,,CCYYMMDDHHMMZZZ,X, + 49,Ende zum,SG4,DTM,,00016,,,,Soll [14],"[9] Wenn SG4 STS+7++ZE4 (Transaktionsgrund: Weggefallene Markt- bzw. Messlokation) nicht vorhanden + [14] Wenn Datum bekannt" + 50,Ende zum,SG4,DTM,2005,00016,93,,Datum Vertragsende,X, + 51,Ende zum,SG4,DTM,2380,00016,,,"Datum oder Uhrzeit oderZeitspanne, Wert",X [UB2], + 52,Ende zum,SG4,DTM,2379,00016,303,,CCYYMMDDHHMMZZZ,X, + 53,"Änderung zum, Gültigkeit, Beginndatum",SG4,DTM,,00018,,,,Muss,[9] Wenn SG4 STS+7++ZE4 (Transaktionsgrund: Weggefallene Markt- bzw. Messlokation) nicht vorhanden + 54,"Änderung zum, Gültigkeit, Beginndatum",SG4,DTM,2005,00018,157,,"Gültigkeit, Beginndatum",X, + 55,"Änderung zum, Gültigkeit, Beginndatum",SG4,DTM,2380,00018,,,"Datum oder Uhrzeit oderZeitspanne, Wert",X [UB2], + 56,"Änderung zum, Gültigkeit, Beginndatum",SG4,DTM,2379,00018,303,,CCYYMMDDHHMMZZZ,X, + 57,Bilanzierungsbeginn,SG4,DTM,,00020,,,,Muss,[9] Wenn SG4 STS+7++ZE4 (Transaktionsgrund: Weggefallene Markt- bzw. Messlokation) nicht vorhanden + 58,Bilanzierungsbeginn,SG4,DTM,2005,00020,158,,Bilanzierungsbeginn,X, + 59,Bilanzierungsbeginn,SG4,DTM,2380,00020,,,"Datum oder Uhrzeit oderZeitspanne, Wert",X [UB2], + 60,Bilanzierungsbeginn,SG4,DTM,2379,00020,303,,CCYYMMDDHHMMZZZ,X, + 61,Bilanzierungsende,SG4,DTM,,00021,,,,Muss [28] ∧[64],"[9] Wenn SG4 STS+7++ZE4 (Transaktionsgrund: Weggefallene Markt- bzw. Messlokation) nicht vorhanden + [28] Wenn SG4 DTM+93 (Ende zum) vorhanden" + 62,Bilanzierungsende,SG4,DTM,2005,00021,159,,Bilanzierungsende,X, + 63,Bilanzierungsende,SG4,DTM,2380,00021,,,"Datum oder Uhrzeit oderZeitspanne, Wert",X [UB2], + 64,Bilanzierungsende,SG4,DTM,2379,00021,303,,CCYYMMDDHHMMZZZ,X, + 65,Transaktionsgrund,SG4,STS,,00026,,,,Muss [2061],[2061] Segment bzw. Segmentgruppe ist genau einmal je SG4 IDE (Vorgang) anzugeben + 66,Transaktionsgrund,SG4,STS,9015,00026,7,,Transaktionsgrund,X, + 67,Transaktionsgrund,SG4,STS,9013,00026,Z15,,Zusätzlicher Datensatz,, + 68,Transaktionsgrund,SG4,STS,9013,,ZE3,,Stammdatenänderung,, + 69,Transaktionsgrund,SG4,STS,9013,,ZE4,,Weggefallene Markt-bzw. Messlokation,, + 70,Transaktionsgrund,SG4,STS,9013,,ZE5,,Initialmeldung,X, + 71,Status der Antwort,SG4,STS,,00028,,,,,[249] Innerhalb eines SG4 IDE müssen alle DE1131 der SG4 STS+E01 den identischen Wert enthalten + 72,Status der Antwort,SG4,STS,9015,00028,E01,,Status der Antwort,, + 73,Status der Antwort,SG4,STS,9013,00028,,,Code des Prüfschritts,, + 74,Status der Antwort,SG4,STS,1131,00028,Codeliste Gas und StromNr. GS_001,,GS_001,, + 75,Bilanzkreiszuordnung zur Marktlokation,SG4,STS,,00030,,,,Muss,[9] Wenn SG4 STS+7++ZE4 (Transaktionsgrund: Weggefallene Markt- bzw. Messlokation) nicht vorhanden + 76,Bilanzkreiszuordnung zur Marktlokation,SG4,STS,9015,00030,Z18,,Bilanzkreiszuordnung zurMarktlokation,X, + 77,Bilanzkreiszuordnung zur Marktlokation,SG4,STS,4405,00030,Z13,,gescheitert,X, + 78,Bilanzkreiszuordnung zur Marktlokation,SG4,STS,4405,,Z14,,erfolgreich,X, + 79,Meldepunkt,SG5,,,,,,,Muss [2061]∧ [583],[583] Hinweis: Verwendung der ID der Marktlokation + 80,Meldepunkt,SG5,LOC,,00035,,,,Muss, + 81,Meldepunkt,SG5,LOC,3227,00035,172,,Meldepunkt,X, + 82,Meldepunkt,SG5,LOC,3225,00035,,,Identifikator,X [950],[950] Format: Marktlokations-ID + 83,Prüfidentifikator,SG6,,,,,,,Muss, + 84,Prüfidentifikator,SG6,RFF,,00037,,,,Muss, + 85,Prüfidentifikator,SG6,RFF,1153,00037,Z13,,Prüfidentifikator,X, + 86,Prüfidentifikator,SG6,RFF,1154,00037,44103,,NBW Gas / Stammdatenzur verbrauchendenMarktlokation,X, + 87,Prüfidentifikator,SG6,RFF,1154,,44104,,NBW Gas / AktualisierteStammdaten zurverbrauchendenMarktlokation,, + 88,Prüfidentifikator,SG6,RFF,1154,,44105,,NBW Gas / Ablehnungauf Stammdaten zurverbrauchendenMarktlokation,, + 89,Referenz Vorgangsnummer (aus Anfragenachricht),SG6,,,,,,,, + 90,Referenz Vorgangsnummer (aus Anfragenachricht),SG6,RFF,,00038,,,,, + 91,Referenz Vorgangsnummer (aus Anfragenachricht),SG6,RFF,1153,00038,TN,,Transaktions-Referenznummer,, + 92,Referenz Vorgangsnummer (aus Anfragenachricht),SG6,RFF,1154,00038,,,Vorgangsnummer,, + 93,Daten der Marktlokation,SG8,,,,,,,Muss,[9] Wenn SG4 STS+7++ZE4 (Transaktionsgrund: Weggefallene Markt- bzw. Messlokation) nicht vorhanden + 94,Daten der Marktlokation,SG8,SEQ,,00049,,,,Muss, + 95,Daten der Marktlokation,SG8,SEQ,1229,00049,Z01,,Daten der Marktlokation,X, + 96,Veranschlagte Jahresmenge gesamt,SG9,,,,,,,Muss [106]∧ [513],[106] Wenn in dieser SG8 SEQ+Z01 SG10 CCI+++ZA6 (Prognosegrundlage der Marktlokation: Prognose auf Basis von Profilen) vorhanden + 97,Veranschlagte Jahresmenge gesamt,SG9,QTY,,00050,,,,Muss, + 98,Veranschlagte Jahresmenge gesamt,SG9,QTY,6063,00050,31,,VeranschlagteJahresmenge Gesamt,X, + 99,Veranschlagte Jahresmenge gesamt,SG9,QTY,6060,00050,,,Mengenangabe,X [902] ∧[937],"[902] Format: Möglicher Wert: ≥ 0 + [937] Format: keine Nachkommastelle" + 100,Veranschlagte Jahresmenge gesamt,SG9,QTY,6411,00050,KWH,,Kilowattstunde,X, + 101,TUM Kundenwert,SG9,,,,,,,Soll [47] ∧[108] ∧[106]Muss [46] ∧[106],"[46] Wenn in SG8 SEQ+Z35 ein SG10 CCI+Z12 (Lastprofil) CAV (Lastprofil) DE3055 der Wert 293 enthalten ist + [47] Wenn in SG8 SEQ+Z35 ein SG10 CCI+Z12 (Lastprofil) CAV (Lastprofil) DE3055 der Wert 293 nicht enthalten ist + [106] Wenn in dieser SG8 SEQ+Z01 SG10 CCI+++ZA6 (Prognosegrundlage der Marktlokation: Prognose auf Basis von Profilen) vorhanden + [108] Wenn Kundenwertverfahren (z. B. TU München)" + 102,TUM Kundenwert,SG9,QTY,,00051,,,,Muss, + 103,TUM Kundenwert,SG9,QTY,6063,00051,Y02,,Kundenwert,X, + 104,TUM Kundenwert,SG9,QTY,6060,00051,,,Mengenangabe,X [902] ∧[907],"[902] Format: Möglicher Wert: ≥ 0 + [907] Format: max. 4 Nachkommastellen" + 105,TUM Kundenwert,SG9,QTY,6411,00051,KWH,,Kilowattstunde,X, + 106,Prognosegrundlage der Marktlokation,SG10,,,,,,,Muss, + 107,Prognosegrundlage der Marktlokation,SG10,CCI,,00058,,,,Muss, + 108,Prognosegrundlage der Marktlokation,SG10,CCI,7037,00058,ZC0,,Prognose auf Basis vonWerten,X, + 109,Prognosegrundlage der Marktlokation,SG10,CCI,7037,,ZA6,,Prognose auf Basis vonProfilen,X, + 110,Fallgruppenzuordnung,SG10,,,,,,,Muss [19],[19] Wenn SG8 SEQ+Z01 (Daten der Marktlokation) SG10 CCI+++ZC0 (Prognose auf Basis von Werten) vorhanden + 111,Fallgruppenzuordnung,SG10,CCI,,00061,,,,Muss, + 112,Fallgruppenzuordnung,SG10,CCI,7037,00061,Z17,,Fallgruppenzuordnungnach GABi Gas,X, + 113,Fallgruppenzuordnung,SG10,CCI,1131,00061,GABi-,,Nominierungsersatzverfa,X, + 114,Fallgruppenzuordnung,SG10,CCI,1131,,RLMNE,,hren - Exit (Hinweis:,, + 115,Fallgruppenzuordnung,SG10,CCI,1131,,V,,Dieser Code darf nur fürLiefermonate vor dem01.10.2016 genutztwerden),, + 116,Fallgruppenzuordnung,SG10,CCI,1131,,GABi-RLMmT,,RLM-Kunde inTagesregime - Exit,X, + 117,Fallgruppenzuordnung,SG10,CCI,1131,,GABi-RLMoT,,RLM-Kunde imStundenregime - Exit,X, + 118,Lastprofildaten,SG8,,,,,,,Muss [106],"[9] Wenn SG4 STS+7++ZE4 (Transaktionsgrund: Weggefallene Markt- bzw. Messlokation) nicht vorhanden + [106] Wenn in dieser SG8 SEQ+Z01 SG10 CCI+++ZA6 (Prognosegrundlage der Marktlokation: Prognose auf Basis von Profilen) vorhanden" + 119,Lastprofildaten,SG8,SEQ,,00127,,,,Muss, + 120,Lastprofildaten,SG8,SEQ,1229,00127,Z35,,Lastprofildaten,X, + 121,Lastprofil,SG10,,,,,,,Muss, + 122,Lastprofil,SG10,CCI,,00128,,,,Muss, + 123,Lastprofil,SG10,CCI,7059,00128,Z12,,Lastprofil,X, + 124,Lastprofil,SG10,CCI,7037,00128,E01,,synthetisches Verfahren,X, + 125,Lastprofil,SG10,CCI,7037,,Z10,,analytisches Verfahren,X, + 126,Lastprofil,SG10,CAV,,00129,,,,Muss, + 127,Lastprofil,SG10,CAV,7111,00129,,,Code des Lastprofils,X, + 128,Lastprofil,SG10,CAV,3055,00129,89,,Vergeben vom Händler(hier Netzbetreiber),X, + 129,Lastprofil,SG10,CAV,3055,,293,,"DE, BDEW(Bundesverband derEnergie- undWasserwirtschaft e.V.)",X, + 130,Klimazone / Temperaturmessstelle,SG10,,,,,,,Muss, + 131,Klimazone / Temperaturmessstelle,SG10,CCI,,00130,,,,Muss, + 132,Klimazone / Temperaturmessstelle,SG10,CCI,7059,00130,Z99,,Messstelle desTagesparameters(derzeit ist nur dieTemperatur ein erlaubterTagesparameter),X, + 133,Klimazone / Temperaturmessstelle,SG10,CCI,7059,,ZA0,,Klimazone desTagesparameters(derzeit istTagesparameter),X, + 134,Klimazone / Temperaturmessstelle,SG10,CCI,7037,00130,,,ID Klimazone /Temperaturmessstelle,X, + 135,Klimazone / Temperaturmessstelle,SG10,CCI,1131,00130,,,Dienstanbieter,X [58],[58] Wenn in diesem CCI das DE3055 mit dem Code 293 vorhanden + 136,Klimazone / Temperaturmessstelle,SG10,CCI,3055,00130,89,,Vergeben vom Händler(hier Netzbetreiber),X, + 137,Klimazone / Temperaturmessstelle,SG10,CCI,3055,,293,,"DE, BDEW(Bundesverband derEnergie- undWasserwirtschaft e.V.)",X, + 138,Beteiligter Marktpartner MP-ID,SG12,,,,,,,Muss [570],[570] Hinweis: Netzbetreiber Alt + 139,Beteiligter Marktpartner MP-ID,SG12,NAD,,00144,,,,Muss, + 140,Beteiligter Marktpartner MP-ID,SG12,NAD,3035,00144,VY,,andere zugehörige Partei,X, + 141,Beteiligter Marktpartner MP-ID,SG12,NAD,3039,00144,,,MP-ID,X, + 142,Beteiligter Marktpartner MP-ID,SG12,NAD,3055,00144,9,,GS1,X, + 143,Beteiligter Marktpartner MP-ID,SG12,NAD,3055,,332,,"DE, DVGW Service &Consult GmbH",X, + 144,Nachrichten-Endesegment,,UNT,,00149,,,,Muss, + 145,Nachrichten-Endesegment,,UNT,0074,00149,,,Anzahl der Segmente in einerNachricht,X, + 146,Nachrichten-Endesegment,,UNT,0062,00149,,,Nachrichten-Referenznummer,X, + + ''' +# --- +# name: TestCli.test_kohlrahbi_cli_with_valid_arguments[44105] + ''' + ,Segmentname,Segmentgruppe,Segment,Datenelement,Segment ID,Code,Qualifier,Beschreibung,Bedingungsausdruck,Bedingung + 0,Nachrichten-Kopfsegment,,UNH,,00003,,,,Muss, + 1,Nachrichten-Kopfsegment,,UNH,0062,00003,,,Nachrichten-Referenznummer,X, + 2,Nachrichten-Kopfsegment,,UNH,0065,00003,UTILMD,,Netzanschluss-Stammdaten,X, + 3,Nachrichten-Kopfsegment,,UNH,0052,00003,D,,Entwurfs-Version,X, + 4,Nachrichten-Kopfsegment,,UNH,0054,00003,11A,,Ausgabe 2011 - A,X, + 5,Nachrichten-Kopfsegment,,UNH,0051,00003,UN,,UN/CEFACT,X, + 6,Nachrichten-Kopfsegment,,UNH,0057,00003,Versionsnummer derzugrundeliegendenBDEW-Nachrichtenbeschreibung,,G1.0a,X, + 7,Nachrichten-Kopfsegment,,UNH,0068,00003,,,Allgemeine Zuordnungs-Referenz,,[1] Wenn Aufteilung vorhanden + 8,Nachrichten-Kopfsegment,,UNH,0070,00003,,,Übermittlungsfolgenummer,,[252] Wenn DE0068 vorhanden + 9,Nachrichten-Kopfsegment,,UNH,0073,00003,C,,Beginn,, + 10,Nachrichten-Kopfsegment,,UNH,0073,,F,,Ende,,"[2] Wenn UNH DE0070 (Übermittlungsfolgenum mer) mit 1 vorhanden + [3] Bei Aufteilung, in der Nachricht mit der höchsten Übermittlungsfolgenum mer" + 11,Beginn der Nachricht,,BGM,,00004,,,,Muss, + 12,Beginn der Nachricht,,BGM,1001,00004,Z22,,Netzbetreiberwechsel,X, + 13,Beginn der Nachricht,,BGM,1004,00004,,,Dokumentennummer,X, + 14,Nachrichtendatum,,DTM,,00005,,,,Muss, + 15,Nachrichtendatum,,DTM,2005,00005,137,,Dokumenten-/Nachrichtendatum/-zeit,X, + 16,Nachrichtendatum,,DTM,2380,00005,,,"Datum oder Uhrzeit oderZeitspanne, Wert",X [931][494],"[494] Das hier genannte Datum muss der Zeitpunkt sein, zu dem das Dokument erstellt wurde, oder ein Zeitpunkt, der davor liegt + [931] Format: ZZZ = +00" + 17,Nachrichtendatum,,DTM,2379,00005,303,,CCYYMMDDHHMMZZZ,X, + 18,MP-ID Absender,SG2,,,,,,,Muss, + 19,MP-ID Absender,SG2,NAD,,00008,,,,Muss, + 20,MP-ID Absender,SG2,NAD,3035,00008,MS,,Dokumenten-/Nachrichtenausstellerbzw. -absender,X, + 21,MP-ID Absender,SG2,NAD,3039,00008,,,MP-ID,X, + 22,MP-ID Absender,SG2,NAD,3055,00008,9,,GS1,X, + 23,MP-ID Absender,SG2,NAD,3055,,332,,"DE, DVGW Service &Consult GmbH",X, + 24,Ansprechpartner,SG3,,,,,,,Kann, + 25,Ansprechpartner,SG3,CTA,,00009,,,,Muss, + 26,Ansprechpartner,SG3,CTA,3139,00009,IC,,Informationskontakt,X, + 27,Ansprechpartner,SG3,CTA,3412,00009,,,Name vom Ansprechpartner,X, + 28,Kommunikationsverbindung,SG3,COM,,00010,,,,Muss, + 29,Kommunikationsverbindung,SG3,COM,3148,00010,,,Nummer / Adresse,X, + 30,Kommunikationsverbindung,SG3,COM,3155,00010,EM,,Elektronische Post,X [1P0..1], + 31,Kommunikationsverbindung,SG3,COM,3155,,FX,,Telefax,X [1P0..1], + 32,Kommunikationsverbindung,SG3,COM,3155,,TE,,Telefon,X [1P0..1], + 33,Kommunikationsverbindung,SG3,COM,3155,,AJ,,weiteres Telefon,X [1P0..1], + 34,Kommunikationsverbindung,SG3,COM,3155,,AL,,Handy,X [1P0..1], + 35,MP-ID Empfänger,SG2,,,,,,,Muss, + 36,MP-ID Empfänger,SG2,NAD,,00011,,,,Muss, + 37,MP-ID Empfänger,SG2,NAD,3035,00011,MR,,Nachrichtenempfänger,X, + 38,MP-ID Empfänger,SG2,NAD,3039,00011,,,MP-ID,X, + 39,MP-ID Empfänger,SG2,NAD,3055,00011,9,,GS1,X, + 40,MP-ID Empfänger,SG2,NAD,3055,,332,,"DE, DVGW Service &Consult GmbH",X, + 41,Vorgang,SG4,,,,,,,Muss , + 42,Vorgang,SG4,IDE,,00012,,,,Muss, + 43,Vorgang,SG4,IDE,7495,00012,24,,Transaktion,X, + 44,Vorgang,SG4,IDE,7402,00012,,,Vorgangsnummer,X, + 45,Beginn zum,SG4,DTM,,00015,,,,,"[9] Wenn SG4 STS+7++ZE4 (Transaktionsgrund: Weggefallene Markt- bzw. Messlokation) nicht vorhanden + [508] Hinweis: Beginndatum beim neuen NB" + 46,Beginn zum,SG4,DTM,2005,00015,92,,Datum Vertragsbeginn,, + 47,Beginn zum,SG4,DTM,2380,00015,,,"Datum oder Uhrzeit oderZeitspanne, Wert",, + 48,Beginn zum,SG4,DTM,2379,00015,303,,CCYYMMDDHHMMZZZ,, + 49,Ende zum,SG4,DTM,,00016,,,,,"[9] Wenn SG4 STS+7++ZE4 (Transaktionsgrund: Weggefallene Markt- bzw. Messlokation) nicht vorhanden + [14] Wenn Datum bekannt" + 50,Ende zum,SG4,DTM,2005,00016,93,,Datum Vertragsende,, + 51,Ende zum,SG4,DTM,2380,00016,,,"Datum oder Uhrzeit oderZeitspanne, Wert",, + 52,Ende zum,SG4,DTM,2379,00016,303,,CCYYMMDDHHMMZZZ,, + 53,"Änderung zum, Gültigkeit, Beginndatum",SG4,DTM,,00018,,,,Muss,[9] Wenn SG4 STS+7++ZE4 (Transaktionsgrund: Weggefallene Markt- bzw. Messlokation) nicht vorhanden + 54,"Änderung zum, Gültigkeit, Beginndatum",SG4,DTM,2005,00018,157,,"Gültigkeit, Beginndatum",X, + 55,"Änderung zum, Gültigkeit, Beginndatum",SG4,DTM,2380,00018,,,"Datum oder Uhrzeit oderZeitspanne, Wert",X [UB2], + 56,"Änderung zum, Gültigkeit, Beginndatum",SG4,DTM,2379,00018,303,,CCYYMMDDHHMMZZZ,X, + 57,Bilanzierungsbeginn,SG4,DTM,,00020,,,,,[9] Wenn SG4 STS+7++ZE4 (Transaktionsgrund: Weggefallene Markt- bzw. Messlokation) nicht vorhanden + 58,Bilanzierungsbeginn,SG4,DTM,2005,00020,158,,Bilanzierungsbeginn,, + 59,Bilanzierungsbeginn,SG4,DTM,2380,00020,,,"Datum oder Uhrzeit oderZeitspanne, Wert",, + 60,Bilanzierungsbeginn,SG4,DTM,2379,00020,303,,CCYYMMDDHHMMZZZ,, + 61,Bilanzierungsende,SG4,DTM,,00021,,,,,"[9] Wenn SG4 STS+7++ZE4 (Transaktionsgrund: Weggefallene Markt- bzw. Messlokation) nicht vorhanden + [28] Wenn SG4 DTM+93 (Ende zum) vorhanden" + 62,Bilanzierungsende,SG4,DTM,2005,00021,159,,Bilanzierungsende,, + 63,Bilanzierungsende,SG4,DTM,2380,00021,,,"Datum oder Uhrzeit oderZeitspanne, Wert",, + 64,Bilanzierungsende,SG4,DTM,2379,00021,303,,CCYYMMDDHHMMZZZ,, + 65,Transaktionsgrund,SG4,STS,,00026,,,,Muss [2061],[2061] Segment bzw. Segmentgruppe ist genau einmal je SG4 IDE (Vorgang) anzugeben + 66,Transaktionsgrund,SG4,STS,9015,00026,7,,Transaktionsgrund,X, + 67,Transaktionsgrund,SG4,STS,9013,00026,Z15,,Zusätzlicher Datensatz,X, + 68,Transaktionsgrund,SG4,STS,9013,,ZE3,,Stammdatenänderung,X, + 69,Transaktionsgrund,SG4,STS,9013,,ZE4,,Weggefallene Markt-bzw. Messlokation,X, + 70,Transaktionsgrund,SG4,STS,9013,,ZE5,,Initialmeldung,X, + 71,Status der Antwort,SG4,STS,,00028,,,,Muss [249],[249] Innerhalb eines SG4 IDE müssen alle DE1131 der SG4 STS+E01 den identischen Wert enthalten + 72,Status der Antwort,SG4,STS,9015,00028,E01,,Status der Antwort,X, + 73,Status der Antwort,SG4,STS,9013,00028,,,Code des Prüfschritts,X, + 74,Status der Antwort,SG4,STS,1131,00028,Codeliste Gas und StromNr. GS_001,,GS_001,X, + 75,Bilanzkreiszuordnung zur Marktlokation,SG4,STS,,00030,,,,,[9] Wenn SG4 STS+7++ZE4 (Transaktionsgrund: Weggefallene Markt- bzw. Messlokation) nicht vorhanden + 76,Bilanzkreiszuordnung zur Marktlokation,SG4,STS,9015,00030,Z18,,Bilanzkreiszuordnung zurMarktlokation,, + 77,Bilanzkreiszuordnung zur Marktlokation,SG4,STS,4405,00030,Z13,,gescheitert,, + 78,Bilanzkreiszuordnung zur Marktlokation,SG4,STS,4405,,Z14,,erfolgreich,, + 79,Meldepunkt,SG5,,,,,,,Muss [2061]∧ [583],[583] Hinweis: Verwendung der ID der Marktlokation + 80,Meldepunkt,SG5,LOC,,00035,,,,Muss, + 81,Meldepunkt,SG5,LOC,3227,00035,172,,Meldepunkt,X, + 82,Meldepunkt,SG5,LOC,3225,00035,,,Identifikator,X [950],[950] Format: Marktlokations-ID + 83,Prüfidentifikator,SG6,,,,,,,Muss, + 84,Prüfidentifikator,SG6,RFF,,00037,,,,Muss, + 85,Prüfidentifikator,SG6,RFF,1153,00037,Z13,,Prüfidentifikator,X, + 86,Prüfidentifikator,SG6,RFF,1154,00037,44103,,NBW Gas / Stammdatenzur verbrauchendenMarktlokation,, + 87,Prüfidentifikator,SG6,RFF,1154,,44104,,NBW Gas / AktualisierteStammdaten zurverbrauchendenMarktlokation,, + 88,Prüfidentifikator,SG6,RFF,1154,,44105,,NBW Gas / Ablehnungauf Stammdaten zurverbrauchendenMarktlokation,X, + 89,Referenz Vorgangsnummer (aus Anfragenachricht),SG6,,,,,,,Muss, + 90,Referenz Vorgangsnummer (aus Anfragenachricht),SG6,RFF,,00038,,,,Muss, + 91,Referenz Vorgangsnummer (aus Anfragenachricht),SG6,RFF,1153,00038,TN,,Transaktions-Referenznummer,X, + 92,Referenz Vorgangsnummer (aus Anfragenachricht),SG6,RFF,1154,00038,,,Vorgangsnummer,X, + 93,Daten der Marktlokation,SG8,,,,,,,,[9] Wenn SG4 STS+7++ZE4 (Transaktionsgrund: Weggefallene Markt- bzw. Messlokation) nicht vorhanden + 94,Daten der Marktlokation,SG8,SEQ,,00049,,,,, + 95,Daten der Marktlokation,SG8,SEQ,1229,00049,Z01,,Daten der Marktlokation,, + 96,Veranschlagte Jahresmenge gesamt,SG9,,,,,,,,[106] Wenn in dieser SG8 SEQ+Z01 SG10 CCI+++ZA6 (Prognosegrundlage der Marktlokation: Prognose auf Basis von Profilen) vorhanden + 97,Veranschlagte Jahresmenge gesamt,SG9,QTY,,00050,,,,, + 98,Veranschlagte Jahresmenge gesamt,SG9,QTY,6063,00050,31,,VeranschlagteJahresmenge Gesamt,, + 99,Veranschlagte Jahresmenge gesamt,SG9,QTY,6060,00050,,,Mengenangabe,,"[902] Format: Möglicher Wert: ≥ 0 + [937] Format: keine Nachkommastelle" + 100,Veranschlagte Jahresmenge gesamt,SG9,QTY,6411,00050,KWH,,Kilowattstunde,, + 101,TUM Kundenwert,SG9,,,,,,,,"[46] Wenn in SG8 SEQ+Z35 ein SG10 CCI+Z12 (Lastprofil) CAV (Lastprofil) DE3055 der Wert 293 enthalten ist + [47] Wenn in SG8 SEQ+Z35 ein SG10 CCI+Z12 (Lastprofil) CAV (Lastprofil) DE3055 der Wert 293 nicht enthalten ist + [106] Wenn in dieser SG8 SEQ+Z01 SG10 CCI+++ZA6 (Prognosegrundlage der Marktlokation: Prognose auf Basis von Profilen) vorhanden + [108] Wenn Kundenwertverfahren (z. B. TU München)" + 102,TUM Kundenwert,SG9,QTY,,00051,,,,, + 103,TUM Kundenwert,SG9,QTY,6063,00051,Y02,,Kundenwert,, + 104,TUM Kundenwert,SG9,QTY,6060,00051,,,Mengenangabe,,"[902] Format: Möglicher Wert: ≥ 0 + [907] Format: max. 4 Nachkommastellen" + 105,TUM Kundenwert,SG9,QTY,6411,00051,KWH,,Kilowattstunde,, + 106,Prognosegrundlage der Marktlokation,SG10,,,,,,,, + 107,Prognosegrundlage der Marktlokation,SG10,CCI,,00058,,,,, + 108,Prognosegrundlage der Marktlokation,SG10,CCI,7037,00058,ZC0,,Prognose auf Basis vonWerten,, + 109,Prognosegrundlage der Marktlokation,SG10,CCI,7037,,ZA6,,Prognose auf Basis vonProfilen,, + 110,Fallgruppenzuordnung,SG10,,,,,,,,[19] Wenn SG8 SEQ+Z01 (Daten der Marktlokation) SG10 CCI+++ZC0 (Prognose auf Basis von Werten) vorhanden + 111,Fallgruppenzuordnung,SG10,CCI,,00061,,,,, + 112,Fallgruppenzuordnung,SG10,CCI,7037,00061,Z17,,Fallgruppenzuordnungnach GABi Gas,, + 113,Fallgruppenzuordnung,SG10,CCI,1131,00061,GABi-,,Nominierungsersatzverfa,, + 114,Fallgruppenzuordnung,SG10,CCI,1131,,RLMNE,,hren - Exit (Hinweis:,, + 115,Fallgruppenzuordnung,SG10,CCI,1131,,V,,Dieser Code darf nur fürLiefermonate vor dem01.10.2016 genutztwerden),, + 116,Fallgruppenzuordnung,SG10,CCI,1131,,GABi-RLMmT,,RLM-Kunde inTagesregime - Exit,, + 117,Fallgruppenzuordnung,SG10,CCI,1131,,GABi-RLMoT,,RLM-Kunde imStundenregime - Exit,, + 118,Lastprofildaten,SG8,,,,,,,,"[9] Wenn SG4 STS+7++ZE4 (Transaktionsgrund: Weggefallene Markt- bzw. Messlokation) nicht vorhanden + [106] Wenn in dieser SG8 SEQ+Z01 SG10 CCI+++ZA6 (Prognosegrundlage der Marktlokation: Prognose auf Basis von Profilen) vorhanden" + 119,Lastprofildaten,SG8,SEQ,,00127,,,,, + 120,Lastprofildaten,SG8,SEQ,1229,00127,Z35,,Lastprofildaten,, + 121,Lastprofil,SG10,,,,,,,, + 122,Lastprofil,SG10,CCI,,00128,,,,, + 123,Lastprofil,SG10,CCI,7059,00128,Z12,,Lastprofil,, + 124,Lastprofil,SG10,CCI,7037,00128,E01,,synthetisches Verfahren,, + 125,Lastprofil,SG10,CCI,7037,,Z10,,analytisches Verfahren,, + 126,Lastprofil,SG10,CAV,,00129,,,,, + 127,Lastprofil,SG10,CAV,7111,00129,,,Code des Lastprofils,, + 128,Lastprofil,SG10,CAV,3055,00129,89,,Vergeben vom Händler(hier Netzbetreiber),, + 129,Lastprofil,SG10,CAV,3055,,293,,"DE, BDEW(Bundesverband derEnergie- undWasserwirtschaft e.V.)",, + 130,Klimazone / Temperaturmessstelle,SG10,,,,,,,, + 131,Klimazone / Temperaturmessstelle,SG10,CCI,,00130,,,,, + 132,Klimazone / Temperaturmessstelle,SG10,CCI,7059,00130,Z99,,Messstelle desTagesparameters(derzeit ist nur dieTemperatur ein erlaubterTagesparameter),, + 133,Klimazone / Temperaturmessstelle,SG10,CCI,7059,,ZA0,,Klimazone desTagesparameters(derzeit istTagesparameter),, + 134,Klimazone / Temperaturmessstelle,SG10,CCI,7037,00130,,,ID Klimazone /Temperaturmessstelle,, + 135,Klimazone / Temperaturmessstelle,SG10,CCI,1131,00130,,,Dienstanbieter,,[58] Wenn in diesem CCI das DE3055 mit dem Code 293 vorhanden + 136,Klimazone / Temperaturmessstelle,SG10,CCI,3055,00130,89,,Vergeben vom Händler(hier Netzbetreiber),, + 137,Klimazone / Temperaturmessstelle,SG10,CCI,3055,,293,,"DE, BDEW(Bundesverband derEnergie- undWasserwirtschaft e.V.)",, + 138,Beteiligter Marktpartner MP-ID,SG12,,,,,,,,[570] Hinweis: Netzbetreiber Alt + 139,Beteiligter Marktpartner MP-ID,SG12,NAD,,00144,,,,, + 140,Beteiligter Marktpartner MP-ID,SG12,NAD,3035,00144,VY,,andere zugehörige Partei,, + 141,Beteiligter Marktpartner MP-ID,SG12,NAD,3039,00144,,,MP-ID,, + 142,Beteiligter Marktpartner MP-ID,SG12,NAD,3055,00144,9,,GS1,, + 143,Beteiligter Marktpartner MP-ID,SG12,NAD,3055,,332,,"DE, DVGW Service &Consult GmbH",, + 144,Nachrichten-Endesegment,,UNT,,00149,,,,Muss, + 145,Nachrichten-Endesegment,,UNT,0074,00149,,,Anzahl der Segmente in einerNachricht,X, + 146,Nachrichten-Endesegment,,UNT,0062,00149,,,Nachrichten-Referenznummer,X, + + ''' +# --- +# name: TestCli.test_kohlrahbi_cli_with_valid_arguments[44112] + ''' + ,Segmentname,Segmentgruppe,Segment,Datenelement,Segment ID,Code,Qualifier,Beschreibung,Bedingungsausdruck,Bedingung + 0,Nachrichten-Kopfsegment,,UNH,,00003,,,,Muss, + 1,Nachrichten-Kopfsegment,,UNH,0062,00003,,,Nachrichten-Referenznummer,X, + 2,Nachrichten-Kopfsegment,,UNH,0065,00003,UTILMD,,Netzanschluss-Stammdaten,X, + 3,Nachrichten-Kopfsegment,,UNH,0052,00003,D,,Entwurfs-Version,X, + 4,Nachrichten-Kopfsegment,,UNH,0054,00003,11A,,Ausgabe 2011 - A,X, + 5,Nachrichten-Kopfsegment,,UNH,0051,00003,UN,,UN/CEFACT,X, + 6,Nachrichten-Kopfsegment,,UNH,0057,00003,Versionsnummer derzugrundeliegendenBDEW-Nachrichtenbeschreibung,,G1.0a,X, + 7,Beginn der Nachricht,,BGM,,00004,,,,Muss, + 8,Beginn der Nachricht,,BGM,1001,00004,E03,,Änderungsmeldungen,X, + 9,Beginn der Nachricht,,BGM,1001,,Z26,,Vorläufige Meldung zurMarktraumumstellung,X, + 10,Beginn der Nachricht,,BGM,1004,00004,,,Dokumentennummer,X, + 11,Nachrichtendatum,,DTM,,00005,,,,Muss, + 12,Nachrichtendatum,,DTM,2005,00005,137,,Dokumenten-/Nachrichtendatum/-zeit,X, + 13,Nachrichtendatum,,DTM,2380,00005,,,"Datum oder Uhrzeit oderZeitspanne, Wert",X [931][494],"[494] Das hier genannte Datum muss der Zeitpunkt sein, zu dem das Dokument erstellt wurde, oder ein Zeitpunkt, der davor liegt + [931] Format: ZZZ = +00" + 14,Nachrichtendatum,,DTM,2379,00005,303,,CCYYMMDDHHMMZZZ,X, + 15,MP-ID Absender,SG2,,,,,,,Muss, + 16,MP-ID Absender,SG2,NAD,,00008,,,,Muss, + 17,MP-ID Absender,SG2,NAD,3035,00008,MS,,Dokumenten-/Nachrichtenausstellerbzw. -absender,X, + 18,MP-ID Absender,SG2,NAD,3039,00008,,,MP-ID,X, + 19,MP-ID Absender,SG2,NAD,3055,00008,9,,GS1,X, + 20,MP-ID Absender,SG2,NAD,3055,,332,,"DE, DVGW Service &Consult GmbH",X, + 21,Ansprechpartner,SG3,,,,,,,Kann, + 22,Ansprechpartner,SG3,CTA,,00009,,,,Muss, + 23,Ansprechpartner,SG3,CTA,3139,00009,IC,,Informationskontakt,X, + 24,Ansprechpartner,SG3,CTA,3412,00009,,,Name vom Ansprechpartner,X, + 25,Kommunikationsverbindung,SG3,COM,,00010,,,,Muss, + 26,Kommunikationsverbindung,SG3,COM,3148,00010,,,Nummer / Adresse,X, + 27,Kommunikationsverbindung,SG3,COM,3155,00010,EM,,Elektronische Post,X [1P0..1], + 28,Kommunikationsverbindung,SG3,COM,3155,,FX,,Telefax,X [1P0..1], + 29,Kommunikationsverbindung,SG3,COM,3155,,TE,,Telefon,X [1P0..1], + 30,Kommunikationsverbindung,SG3,COM,3155,,AJ,,weiteres Telefon,X [1P0..1], + 31,Kommunikationsverbindung,SG3,COM,3155,,AL,,Handy,X [1P0..1], + 32,MP-ID Empfänger,SG2,,,,,,,Muss, + 33,MP-ID Empfänger,SG2,NAD,,00011,,,,Muss, + 34,MP-ID Empfänger,SG2,NAD,3035,00011,MR,,Nachrichtenempfänger,X, + 35,MP-ID Empfänger,SG2,NAD,3039,00011,,,MP-ID,X, + 36,MP-ID Empfänger,SG2,NAD,3055,00011,9,,GS1,X, + 37,MP-ID Empfänger,SG2,NAD,3055,,332,,"DE, DVGW Service &Consult GmbH",X, + 38,Vorgang,SG4,,,,,,,Muss, + 39,Vorgang,SG4,IDE,,00012,,,,Muss, + 40,Vorgang,SG4,IDE,7495,00012,24,,Transaktion,X, + 41,Vorgang,SG4,IDE,7402,00012,,,Vorgangsnummer,X, + 42,Beginn zum,SG4,DTM,,00015,,,,Muss, + 43,Beginn zum,SG4,DTM,2005,00015,92,,Datum Vertragsbeginn,X, + 44,Beginn zum,SG4,DTM,2380,00015,,,"Datum oder Uhrzeit oderZeitspanne, Wert",X [UB2], + 45,Beginn zum,SG4,DTM,2379,00015,303,,CCYYMMDDHHMMZZZ,X, + 46,"Änderung zum, Gültigkeit, Beginndatum",SG4,DTM,,00018,,,,Muss, + 47,"Änderung zum, Gültigkeit, Beginndatum",SG4,DTM,2005,00018,157,,"Gültigkeit, Beginndatum",X, + 48,"Änderung zum, Gültigkeit, Beginndatum",SG4,DTM,2380,00018,,,"Datum oder Uhrzeit oderZeitspanne, Wert",X [UB2], + 49,"Änderung zum, Gültigkeit, Beginndatum",SG4,DTM,2379,00018,303,,CCYYMMDDHHMMZZZ,X, + 50,Transaktionsgrund,SG4,STS,,00026,,,,Muss [2061],[2061] Segment bzw. Segmentgruppe ist genau einmal je SG4 IDE (Vorgang) anzugeben + 51,Transaktionsgrund,SG4,STS,9015,00026,7,,Transaktionsgrund,X, + 52,Transaktionsgrund,SG4,STS,9013,00026,ZE7,,Nicht bila.rel. Änderungvom NB,X, + 53,Status der Antwort,SG4,STS,,00028,,,,,[249] Innerhalb eines SG4 IDE müssen alle DE1131 der SG4 STS+E01 den identischen Wert enthalten + 54,Status der Antwort,SG4,STS,9015,00028,E01,,Status der Antwort,, + 55,Status der Antwort,SG4,STS,9013,00028,,,Code des Prüfschritts,, + 56,Status der Antwort,SG4,STS,1131,00028,G_0016,,Codeliste Gas Nr.G_0016,, + 57,Meldepunkt,SG5,,,,,,,Muss ([32]∧ [2061] ∧[651]) ⊻([200] ∧[601]),"[32] Wenn BGM+E03 (Änderungsmeldungen) vorhanden + [200] Wenn BGM+Z26 (Vorläufige Meldung zur Marktraumumstellung) vorhanden + [601] Hinweis: Es ist die ID der Marktlokation und alle Identifikatoren der Messlokationen anzugeben. + [651] Hinweis: Bei einer Marktraumumstellung (Gas) ist zu beachten, dass die tatsächliche Meldung zur Marktraumumstellung auf Ebene der Messlokation durch Angabe der Gasqualität erfolgt. Die betroffene Marktlokation ist vom LF und MSB selbst festzustellen + [2061] Segment bzw. Segmentgruppe ist genau einmal je SG4 IDE (Vorgang) anzugeben" + 58,Meldepunkt,SG5,LOC,,00035,,,,Muss, + 59,Meldepunkt,SG5,LOC,3227,00035,172,,Meldepunkt,X, + 60,Meldepunkt,SG5,LOC,3225,00035,,,Identifikator,X [953],[953] Format: Marktlokations-ID oder Zählpunktbezeichnung + 61,Prüfidentifikator,SG6,,,,,,,Muss, + 62,Prüfidentifikator,SG6,RFF,,00037,,,,Muss, + 63,Prüfidentifikator,SG6,RFF,1153,00037,Z13,,Prüfidentifikator,X, + 64,Prüfidentifikator,SG6,RFF,1154,00037,44112,,SDÄ Gas / Nicht bila.rel.Änderung vom NB an LF,X, + 65,Prüfidentifikator,SG6,RFF,1154,,44113,,SDÄ Gas / Nicht bila.rel.Änderung vom NB anMSB,, + 66,Prüfidentifikator,SG6,RFF,1154,,44115,,SDÄ Gas / Antwort aufÄnderung vom NB AG anNB,, + 67,Referenz Vorgangsnummer (aus Anfragenachricht),SG6,,,,,,,, + 68,Referenz Vorgangsnummer (aus Anfragenachricht),SG6,RFF,,00038,,,,, + 69,Referenz Vorgangsnummer (aus Anfragenachricht),SG6,RFF,1153,00038,TN,,Transaktions-Referenznummer,, + 70,Referenz Vorgangsnummer (aus Anfragenachricht),SG6,RFF,1154,00038,,,Vorgangsnummer,, + 71,Referenz auf die ID der Marktlokation für Termine der Marktlokation,SG6,,,,,,,Soll [25] ∧[92],"[25] Wenn der Meldepunkt im SG5 LOC+172 (Meldepunkt) DE3225 das Format der Marktlokations-ID hat + [92] Wenn Wert innerhalb SG bzw. Segment geändert wird" + 72,Referenz auf die ID der Marktlokation für Termine der Marktlokation,SG6,RFF,,00041,,,,Muss [636],[636] Hinweis: Dieses RFF klassifiziert mit einem Code im DE1153 die in derselben Segmentgruppe enthaltenen DTM zu einem Markt- bzw. Messlokation relevanten Inhalt + 73,Referenz auf die ID der Marktlokation für Termine der Marktlokation,SG6,RFF,1153,00041,Z18,,Marktlokation,X, + 74,Referenz auf die ID der Marktlokation für Termine der Marktlokation,SG6,RFF,1154,00041,,,ID der Marktlokation,X [950],[950] Format: Marktlokations-ID + 75,Start des Abrechnungsjahrs bei Marktlokationen mit Jahresleistungspreis,SG6,DTM,,00042,,,,Soll [92],[92] Wenn Wert innerhalb SG bzw. Segment geändert wird + 76,Start des Abrechnungsjahrs bei Marktlokationen mit Jahresleistungspreis,SG6,DTM,2005,00042,155,,"Rechnungsperiode,Beginndatum",X, + 77,Start des Abrechnungsjahrs bei Marktlokationen mit Jahresleistungspreis,SG6,DTM,2380,00042,,,"Datum oder Uhrzeit oderZeitspanne, Wert",X [UB2], + 78,Start des Abrechnungsjahrs bei Marktlokationen mit Jahresleistungspreis,SG6,DTM,2379,00042,303,,CCYYMMDDHHMMZZZ,X, + 79,Termin der Netznutzungsabrechnung,SG6,DTM,,00044,,,,Soll [92],[92] Wenn Wert innerhalb SG bzw. Segment geändert wird + 80,Termin der Netznutzungsabrechnung,SG6,DTM,2005,00044,Z21,,Termin derNetznutzungsabrechnung,X, + 81,Termin der Netznutzungsabrechnung,SG6,DTM,2380,00044,,,"Datum oder Uhrzeit oderZeitspanne, Wert",X, + 82,Termin der Netznutzungsabrechnung,SG6,DTM,2379,00044,106,,MMDD,X, + 83,Termin der Netznutzungsabrechnung,SG6,DTM,2379,,104,,MMWW-MMWW,X, + 84,Nächste Netznutzungsabrechnung,SG6,DTM,,00045,,,,Muss [24] ∧[230],"[24] Wenn SG6 DTM+Z21 (Termin der Netznutzungsabrechnun g) vorhanden + [230] Sich ergebendes Datum/ bzw. Endedatum des Turnuszeitraums aus DTM+Z21 (Termin der Netznutzungsabrechnun g) und DTM+Z09 (Nächste Netznutzungsabrechnun g) muss >= DTM+92 (Beginn zum) sein" + 85,Nächste Netznutzungsabrechnung,SG6,DTM,2005,00045,Z09,,NächsteNetznutzungsabrechnung,X, + 86,Nächste Netznutzungsabrechnung,SG6,DTM,2380,00045,,,"Datum oder Uhrzeit oderZeitspanne, Wert",X, + 87,Nächste Netznutzungsabrechnung,SG6,DTM,2379,00045,602,,CCYY,X, + 88,Netznutzungsabrechnungsi ntervall des NB,SG6,DTM,,00046,,,,Soll [92],[92] Wenn Wert innerhalb SG bzw. Segment geändert wird + 89,Netznutzungsabrechnungsi ntervall des NB,SG6,DTM,2005,00046,Z22,,Netznutzungsabrechnungs- bzw.Einspeisevergütungsintervall des NB,X [504],[504] Hinweis: Der Code Z22 wird auch in der Sparte Strom genutzt. Der Verweis auf den Einspeisevergütungsinter vall ist in der Sparte Gas nicht relevant. + 90,Netznutzungsabrechnungsi ntervall des NB,SG6,DTM,2380,00046,,,"Datum oder Uhrzeit oderZeitspanne, Wert",X, + 91,Netznutzungsabrechnungsi ntervall des NB,SG6,DTM,2379,00046,802,,Monat,X, + 92,Referenz auf die ID der Messlokation für Termine der Messlokation,SG6,,,,,,,,"[26] Wenn der Meldepunkt im SG5 LOC+172 (Meldepunkt) DE3225 das Format der Zählpunktbezeichnung hat + [92] Wenn Wert innerhalb SG bzw. Segment geändert wird" + 93,Referenz auf die ID der Messlokation für Termine der Messlokation,SG6,RFF,,00047,,,,,[636] Hinweis: Dieses RFF klassifiziert mit einem Code im DE1153 die in derselben Segmentgruppe enthaltenen DTM zu einem Markt- bzw. Messlokation relevanten Inhalt + 94,Referenz auf die ID der Messlokation für Termine der Messlokation,SG6,RFF,1153,00047,Z19,,Messlokation,, + 95,Referenz auf die ID der Messlokation für Termine der Messlokation,SG6,RFF,1154,00047,,,ID der Messlokation,,[951] Format: Zählpunktbezeichnung + 96,Turnusablesung des NB,SG6,DTM,,00048,,,,,[92] Wenn Wert innerhalb SG bzw. Segment geändert wird + 97,Turnusablesung des NB,SG6,DTM,2005,00048,752,,Turnusablesung,, + 98,Turnusablesung des NB,SG6,DTM,2380,00048,,,"Datum oder Uhrzeit oderZeitspanne, Wert",, + 99,Turnusablesung des NB,SG6,DTM,2379,00048,104,,MMWW-MMWW,, + 100,Turnusablesung des NB,SG6,DTM,2379,,106,,MMDD,, + 101,Daten der Marktlokation,SG8,,,,,,,Soll [25] ∧[92]Muss [200],"[25] Wenn der Meldepunkt im SG5 LOC+172 (Meldepunkt) DE3225 das Format der Marktlokations-ID hat + [92] Wenn Wert innerhalb SG bzw. Segment geändert wird + [200] Wenn BGM+Z26 (Vorläufige Meldung zur" + 102,Daten der Marktlokation,SG8,SEQ,,00049,,,,Muss, + 103,Daten der Marktlokation,SG8,SEQ,1229,00049,Z01,,Daten der Marktlokation,X, + 104,Marktgebiet,SG10,,,,,,,Soll [92]Muss [200],"[92] Wenn Wert innerhalb SG bzw. Segment geändert wird + [200] Wenn BGM+Z26 (Vorläufige Meldung zur Marktraumumstellung) vorhanden" + 105,Marktgebiet,SG10,CCI,,00055,,,,Muss, + 106,Marktgebiet,SG10,CCI,7059,00055,Z21,,Marktgebiet,X, + 107,Marktgebiet,SG10,CCI,7037,00055,,,Marktgebiet,X, + 108,Druckebene der Marktlokation,SG10,,,,,,,Soll [92],[92] Wenn Wert innerhalb SG bzw. Segment geändert wird + 109,Druckebene der Marktlokation,SG10,CCI,,00056,,,,Muss, + 110,Druckebene der Marktlokation,SG10,CCI,7037,00056,Y01,,Druckebene derMarktlokation,X, + 111,Druckebene der Marktlokation,SG10,CAV,,00057,,,,Muss, + 112,Druckebene der Marktlokation,SG10,CAV,7111,00057,Y01,,Hochdruck,X, + 113,Druckebene der Marktlokation,SG10,CAV,7111,,Y02,,Mitteldruck,X, + 114,Druckebene der Marktlokation,SG10,CAV,7111,,Y03,,Niederdruck,X, + 115,Netznutzung,SG10,,,,,,,Soll [92],[92] Wenn Wert innerhalb SG bzw. Segment geändert wird + 116,Netznutzung,SG10,CCI,,00062,,,,Muss, + 117,Netznutzung,SG10,CCI,7037,00062,Z88,,Netznutzung,X, + 118,Netznutzungsvertrag,SG10,CAV,,00063,,,,Muss, + 119,Netznutzungsvertrag,SG10,CAV,7111,00063,Z74,,Netznutzungsvertrag,X, + 120,Netznutzungsvertrag,SG10,CAV,7110,00063,Z08,,Direkter Vertragzwischen Kunden und NB,X, + 121,Netznutzungsvertrag,SG10,CAV,7110,,Z09,,Vertrag zwischenLieferanten und NB,X, + 122,Zahlung der Netznutzung,SG10,CAV,,00064,,,,Muss, + 123,Zahlung der Netznutzung,SG10,CAV,7111,00064,Z73,,Zahlung der Netznutzung,X, + 124,Zahlung der Netznutzung,SG10,CAV,7110,00064,Z10,,Kunde,X [216], + 125,Zahlung der Netznutzung,SG10,CAV,7110,,Z11,,Lieferant,X,[216] Wenn CCI+++Z88 (Netznutzung) CAV+Z74:::Z08 (Netznutzungsvertrag: Direkter Vertrag zwischen Kunden und NB) vorhanden + 126,Netznutzungsabrechnungsv ariante,SG10,CAV,,00065,,,,Muss, + 127,Netznutzungsabrechnungsv ariante,SG10,CAV,7111,00065,ZB1,,Netznutzungsabrechnungsvariante,X, + 128,Netznutzungsabrechnungsv ariante,SG10,CAV,7110,00065,Z14,,Arbeitspreis/Grundpreis,X, + 129,Netznutzungsabrechnungsv ariante,SG10,CAV,7110,,Z15,,Arbeitspreis/Leistungspreis,X, + 130,OBIS-Daten der Marktlokation,SG8,,,,,,,Soll [25] ∧[92] ∧ [530],"[25] Wenn der Meldepunkt im SG5 LOC+172 (Meldepunkt) DE3225 das Format der Marktlokations-ID hat + [92] Wenn Wert innerhalb SG bzw. Segment geändert wird + [530] Hinweis: Es sind alle an dem Meldepunkt vorhandenen Daten, die mit dieser Segmentgruppe übermittelt werden und zum Datum „Änderung zum“ Gültigkeit haben, anzugeben. Dies kann zur Folge haben, dass Segmentgruppen bzw. Segmente zu wiederholen sind" + 131,OBIS-Daten der Marktlokation,SG8,SEQ,,00067,,,,Muss, + 132,OBIS-Daten der Marktlokation,SG8,SEQ,1229,00067,Z02,,OBIS-Daten derMarktlokation,X, + 133,OBIS-Kennzahl der Marktlokation,SG8,PIA,,00068,,,,Muss, + 134,OBIS-Kennzahl der Marktlokation,SG8,PIA,4347,00068,5,,Produktidentifikation,X, + 135,OBIS-Kennzahl der Marktlokation,SG8,PIA,7140,00068,,,OBIS-Kennzahl der Marktlokation,X [315],[315] Es sind alle + 136,OBIS-Kennzahl der Marktlokation,SG8,PIA,7143,00068,SRW,,OBIS-Kennzahl,X, + 137,Wertegranularität,SG10,,,,,,,Muss [257],[257] Wenn in derselben SG8 SEQ+Z02 (OBIS- Daten der Marktlokation) das PIA+5+7-0?:33.86.0 vorhanden + 138,Wertegranularität,SG10,CCI,,00069,,,,Muss, + 139,Wertegranularität,SG10,CCI,7037,00069,ZE4,,Wertegranularität,X, + 140,Wertegranularität,SG10,CAV,,00070,,,,Muss, + 141,Wertegranularität,SG10,CAV,7111,00070,ZD9,,Jährlich,X, + 142,Wertegranularität,SG10,CAV,7111,,ZE8,,Halbjährlich,X, + 143,Wertegranularität,SG10,CAV,7111,,ZE9,,Quartalsweise,X, + 144,Wertegranularität,SG10,CAV,7111,,ZB7,,Monatlich,X, + 145,Konzessionsabgabedaten,SG8,,,,,,,Soll [25] ∧[92] ∧ [530],"[25] Wenn der Meldepunkt im SG5 LOC+172 (Meldepunkt) DE3225 das Format der Marktlokations-ID hat + [92] Wenn Wert innerhalb SG bzw. Segment geändert wird + [530] Hinweis: Es sind alle an dem Meldepunkt vorhandenen Daten, die mit dieser Segmentgruppe übermittelt werden und" + 146,Konzessionsabgabedaten,SG8,SEQ,,00071,,,,Muss, + 147,Konzessionsabgabedaten,SG8,SEQ,1229,00071,Z07,,Konzessionsabgabedaten,X, + 148,Referenz auf die OBIS- Kennzahl der Marktlokation,SG8,RFF,,00072,,,,Muss, + 149,Referenz auf die OBIS- Kennzahl der Marktlokation,SG8,RFF,1153,00072,Z10,,OBIS-Kennzahl,X, + 150,Referenz auf die OBIS- Kennzahl der Marktlokation,SG8,RFF,1154,00072,,,OBIS-Kennzahl,X, + 151,Zuordnung Konzessionsabgabe,SG10,,,,,,,Muss, + 152,Zuordnung Konzessionsabgabe,SG10,CCI,,00073,,,,Muss, + 153,Zuordnung Konzessionsabgabe,SG10,CCI,7037,00073,Z08,,Konzessionsabgabe,X, + 154,Konzessionsabgabe,SG10,CAV,,00074,,,,Muss, + 155,Konzessionsabgabe,SG10,CAV,7111,00074,KAS,,"für allekonzessionsvertraglichenSonderregelungen, dienicht in die Systematikder KAV eingegliedertsind",X, + 156,Konzessionsabgabe,SG10,CAV,7111,,SA,,"Sondervertragskunden <1 kV nach § 2 (7) und > 1kV, Preis nach § 2 (3) (fürStrom 0,11 ct/kWh undfür Gas 0,03 ct/kWh)",X, + 157,Konzessionsabgabe,SG10,CAV,7111,,SAS,,"Kennzeichnung, dass einabweichender Preis fürSondervertragskundenvorliegt",X, + 158,Konzessionsabgabe,SG10,CAV,7111,,TA,,"Tarifkunden, für Strom §2. (2) 1b HT bzw. ET(hohe KA) und für Gas §2 (2) 2b",X, + 159,Konzessionsabgabe,SG10,CAV,7111,,TAS,,"Kennzeichnung, dass einabweichender Preis fürTarifkunden vorliegt",X, + 160,Konzessionsabgabe,SG10,CAV,7111,,TK,,für Gas nach KAV § 2 (2)2a bei ausschließlicherNutzung zum KochenundWarmwassererzeugung,X, + 161,Konzessionsabgabe,SG10,CAV,7111,,TKS,,"Kennzeichnung, wenn",X, + 162,Konzessionsabgabe,SG10,CAV,7110,00074,,,Konzessionsabgabe in Euro/kWh,Muss [912]∧ [902][128] ,"[128] Wenn SG10 CAV+TAS/ TKS/ SAS/ KAS vorhanden + [902] Format: Möglicher Wert: ≥ 0 + [912] Format: max. 6 Nachkommastellen" + 163,Konzessionsabgabe,SG10,CAV,7110,00074,,,Gebührenkategorie derKonzessionsabgabe,Soll [219],[219] Wenn an Marktlokation vorhanden + 164,Gemeinderabatt,SG8,,,,,,,Soll [25] ∧[92],"[25] Wenn der Meldepunkt im SG5 LOC+172 (Meldepunkt) DE3225 das Format der Marktlokations-ID hat + [92] Wenn Wert innerhalb SG bzw. Segment geändert wird" + 165,Gemeinderabatt,SG8,SEQ,,00075,,,,Muss, + 166,Gemeinderabatt,SG8,SEQ,1229,00075,Z12,,Gemeinderabatt,X, + 167,Gemeinderabatt,SG9,,,,,,,Muss, + 168,Gemeinderabatt,SG9,QTY,,00076,,,,Muss, + 169,Gemeinderabatt,SG9,QTY,6063,00076,Z16,,Gemeinderabatt,X, + 170,Gemeinderabatt,SG9,QTY,6060,00076,,,Menge,X [902] ∧[930] ∧[938],"[902] Format: Möglicher Wert: ≥ 0 + [930] Format: max. 2 Nachkommastellen + [938] Format: Möglicher Wert: <= 10" + 171,Gemeinderabatt,SG9,QTY,6411,00076,P1,,Prozent,X, + 172,Daten der Messlokation,SG8,,,,,,,Soll [92] ∧[345]Muss [200],"[92] Wenn Wert innerhalb SG bzw. Segment geändert wird + [200] Wenn BGM+Z26 (Vorläufige Meldung zur Marktraumumstellung) vorhanden + [345] Wenn 33-stelliger" + 173,Daten der Messlokation,SG8,SEQ,,00077,,,,Muss, + 174,Daten der Messlokation,SG8,SEQ,1229,00077,Z18,,Daten der Messlokation,X, + 175,Referenz auf die ID der Messlokation,SG8,RFF,,00078,,,,Muss, + 176,Referenz auf die ID der Messlokation,SG8,RFF,1153,00078,Z19,,Messlokation,X, + 177,Referenz auf die ID der Messlokation,SG8,RFF,1154,00078,,,ID der Messlokation,X [951],[951] Format: Zählpunktbezeichnung + 178,Zugeordnete Marktpartner,SG10,,,,,,,Soll [92],[92] Wenn Wert innerhalb SG bzw. Segment geändert wird + 179,Zugeordnete Marktpartner,SG10,CCI,,00079,,,,Muss, + 180,Zugeordnete Marktpartner,SG10,CCI,7037,00079,ZB3,,ZugeordneterMarktpartner,X, + 181,Messstellenbetreiber,SG10,CAV,,00080,,,,Muss, + 182,Messstellenbetreiber,SG10,CAV,7111,00080,Z91,,MSB,X, + 183,Messstellenbetreiber,SG10,CAV,1131,00080,,,MP-ID,X, + 184,Messstellenbetreiber,SG10,CAV,7110,00080,Z19,,Auf vertraglicherGrundlage gegenüberAnschlussnutzer /Anschlussnehmer,X, + 185,Messstellenbetreiber,SG10,CAV,7110,,Z20,,In der Ausübung derWeiterverpflichtungdurch den gMSB,X, + 186,Grundzuständiger Messstellenbetreiber,SG10,CAV,,00081,,,,Muss, + 187,Grundzuständiger Messstellenbetreiber,SG10,CAV,7111,00081,ZF0,,gMSB,X, + 188,Grundzuständiger Messstellenbetreiber,SG10,CAV,1131,00081,,,MP-ID,X, + 189,Gasqualität,SG10,,,,,,,Soll [92]Muss [200],"[92] Wenn Wert innerhalb SG bzw. Segment geändert wird + [200] Wenn BGM+Z26 (Vorläufige Meldung zur Marktraumumstellung) vorhanden" + 190,Gasqualität,SG10,CCI,,00083,,,,Muss, + 191,Gasqualität,SG10,CCI,7037,00083,Y02,,Gasqualität,X, + 192,Gasqualität,SG10,CAV,,00084,,,,Muss, + 193,Gasqualität,SG10,CAV,7111,00084,Y04,,H-Gas,X, + 194,Gasqualität,SG10,CAV,7111,,Y05,,L-Gas,X, + 195,Kunde des Netzbetreibers,SG12,,,,,,,Kann [92] ∧[558],"[92] Wenn Wert innerhalb SG bzw. Segment geändert wird + [558] Hinweis: Diese Information kann freiwillig ausgetauscht werden" + 196,Kunde des Netzbetreibers,SG12,NAD,,00140,,,,Muss, + 197,Kunde des Netzbetreibers,SG12,NAD,3035,00140,Z25,,Kunde des NB,X, + 198,Kunde des Netzbetreibers,SG12,NAD,3036,00140,,,Name,X, + 199,Kunde des Netzbetreibers,SG12,NAD,3045,00140,Z01,,Struktur vonPersonennamen,X, + 200,Kunde des Netzbetreibers,SG12,NAD,3045,,Z02,,Struktur derFirmenbezeichnung,X, + 201,Korrespondenzanschrift des Kunde des Netzbetreibers,SG12,,,,,,,Kann [92] ∧[558],"[92] Wenn Wert innerhalb SG bzw. Segment geändert wird + [558] Hinweis: Diese Information kann freiwillig ausgetauscht werden" + 202,Korrespondenzanschrift des Kunde des Netzbetreibers,SG12,NAD,,00141,,,,Muss, + 203,Korrespondenzanschrift des Kunde des Netzbetreibers,SG12,NAD,3035,00141,Z26,,Korrespondenzanschriftdes Kunden des NB,X, + 204,Korrespondenzanschrift des Kunde des Netzbetreibers,SG12,NAD,3036,00141,,,Name,X, + 205,Korrespondenzanschrift des Kunde des Netzbetreibers,SG12,NAD,3045,00141,Z01,,Struktur vonPersonennamen,X, + 206,Korrespondenzanschrift des Kunde des Netzbetreibers,SG12,NAD,3045,,Z02,,Struktur derFirmenbezeichnung,X, + 207,Korrespondenzanschrift des Kunde des Netzbetreibers,SG12,NAD,3042,00141,,,Straße und Hausnummer oderPostfach,X, + 208,Korrespondenzanschrift des Kunde des Netzbetreibers,SG12,NAD,3164,00141,,,Ort,X, + 209,Korrespondenzanschrift des Kunde des Netzbetreibers,SG12,NAD,3251,00141,,,Postleitzahl,M [268]S [166],"[166] Wenn vorhanden + [268] Wenn der Code im DE3207 in der ""EDI@Energy Codeliste der europäischen Ländercodes"" in der Spalte ""PLZ vorhanden"" ein ""X"" aufgeführt ist" + 210,Korrespondenzanschrift des Kunde des Netzbetreibers,SG12,NAD,3207,00141,,,"Ländername, Code",X, + 211,Netzanschlusseigentümer,SG12,,,,,,,Kann [92] ∧[558],"[92] Wenn Wert innerhalb SG bzw. Segment geändert wird + [558] Hinweis: Diese Information kann freiwillig ausgetauscht werden" + 212,Netzanschlusseigentümer,SG12,NAD,,00142,,,,Muss, + 213,Netzanschlusseigentümer,SG12,NAD,3035,00142,EO,,Anschlussnehmer,X, + 214,Netzanschlusseigentümer,SG12,NAD,3036,00142,,,Name,X, + 215,Netzanschlusseigentümer,SG12,NAD,3045,00142,Z01,,Struktur vonPersonennamen,X, + 216,Netzanschlusseigentümer,SG12,NAD,3045,,Z02,,Struktur derFirmenbezeichnung,X, + 217,Netzanschlusseigentümer,SG12,NAD,3042,00142,,,Straße und Hausnummer oderPostfach,X, + 218,Netzanschlusseigentümer,SG12,NAD,3164,00142,,,Ort,X, + 219,Netzanschlusseigentümer,SG12,NAD,3251,00142,,,Postleitzahl,M [268]S [166],"[166] Wenn vorhanden + [268] Wenn der Code im DE3207 in der ""EDI@Energy Codeliste der europäischen Ländercodes"" in der Spalte ""PLZ vorhanden"" ein ""X"" aufgeführt ist" + 220,Netzanschlusseigentümer,SG12,NAD,3207,00142,,,"Ländername, Code",Muss, + 221,Hausverwalter,SG12,,,,,,,Kann [92] ∧[558],"[92] Wenn Wert innerhalb SG bzw. Segment geändert wird + [558] Hinweis: Diese Information kann freiwillig ausgetauscht werden" + 222,Hausverwalter,SG12,NAD,,00143,,,,Muss, + 223,Hausverwalter,SG12,NAD,3035,00143,DDO,,Location manager,X, + 224,Hausverwalter,SG12,NAD,3036,00143,,,Name,X, + 225,Hausverwalter,SG12,NAD,3045,00143,Z01,,Struktur vonPersonennamen,X, + 226,Hausverwalter,SG12,NAD,3045,,Z02,,Struktur derFirmenbezeichnung,X, + 227,Hausverwalter,SG12,NAD,3042,00143,,,Straße und Hausnummer oderPostfach,X, + 228,Hausverwalter,SG12,NAD,3164,00143,,,Ort,X, + 229,Hausverwalter,SG12,NAD,3251,00143,,,Postleitzahl,M [268]S [166],[166] Wenn vorhanden + 230,Hausverwalter,SG12,NAD,3207,00143,,,"Ländername, Code",Muss, + 231,Marktlokationsanschrift,SG12,,,,,,,Soll [92],[92] Wenn Wert innerhalb SG bzw. Segment geändert wird + 232,Marktlokationsanschrift,SG12,NAD,,00145,,,,Muss, + 233,Marktlokationsanschrift,SG12,NAD,3035,00145,DP,,Lieferanschrift,X, + 234,Marktlokationsanschrift,SG12,NAD,3124,00145,,,Zusatzinformation zurIdentifizierung,K, + 235,Marktlokationsanschrift,SG12,NAD,3042,00145,,,Straße und Hausnummer oderPostfach,S [166]M [212],"[166] Wenn vorhanden + [212] Wenn im selben SG12 NAD DE3124 nicht vorhanden" + 236,Marktlokationsanschrift,SG12,NAD,3164,00145,,,Ort,X, + 237,Marktlokationsanschrift,SG12,NAD,3251,00145,,,Postleitzahl,X, + 238,Marktlokationsanschrift,SG12,NAD,3207,00145,,,"Ländername, Code",X, + 239,Nachrichten-Endesegment,,UNT,,00149,,,,Muss, + 240,Nachrichten-Endesegment,,UNT,0074,00149,,,Anzahl der Segmente in einerNachricht,X, + 241,Nachrichten-Endesegment,,UNT,0062,00149,,,Nachrichten-Referenznummer,X, + + ''' +# --- +# name: TestCli.test_kohlrahbi_cli_with_valid_arguments[44117] + ''' + ,Segmentname,Segmentgruppe,Segment,Datenelement,Segment ID,Code,Qualifier,Beschreibung,Bedingungsausdruck,Bedingung + 0,Nachrichten-Kopfsegment,,UNH,,00003,,,,Muss, + 1,Nachrichten-Kopfsegment,,UNH,0062,00003,,,Nachrichten-Referenznummer,X, + 2,Nachrichten-Kopfsegment,,UNH,0065,00003,UTILMD,,Netzanschluss-Stammdaten,X, + 3,Nachrichten-Kopfsegment,,UNH,0052,00003,D,,Entwurfs-Version,X, + 4,Nachrichten-Kopfsegment,,UNH,0054,00003,11A,,Ausgabe 2011 - A,X, + 5,Nachrichten-Kopfsegment,,UNH,0051,00003,UN,,UN/CEFACT,X, + 6,Nachrichten-Kopfsegment,,UNH,0057,00003,Versionsnummer derzugrundeliegendenBDEW-Nachrichtenbeschreibung,,G1.0a,X, + 7,Beginn der Nachricht,,BGM,,00004,,,,Muss, + 8,Beginn der Nachricht,,BGM,1001,00004,E03,,Änderungsmeldungen,X, + 9,Beginn der Nachricht,,BGM,1004,00004,,,Dokumentennummer,X, + 10,Nachrichtendatum,,DTM,,00005,,,,Muss, + 11,Nachrichtendatum,,DTM,2005,00005,137,,Dokumenten-/Nachrichtendatum/-zeit,X, + 12,Nachrichtendatum,,DTM,2380,00005,,,"Datum oder Uhrzeit oderZeitspanne, Wert",X [931][494],"[494] Das hier genannte Datum muss der Zeitpunkt sein, zu dem das Dokument erstellt wurde, oder ein Zeitpunkt, der davor liegt + [931] Format: ZZZ = +00" + 13,Nachrichtendatum,,DTM,2379,00005,303,,CCYYMMDDHHMMZZZ,X, + 14,MP-ID Absender,SG2,,,,,,,Muss, + 15,MP-ID Absender,SG2,NAD,,00008,,,,Muss, + 16,MP-ID Absender,SG2,NAD,3035,00008,MS,,Dokumenten-/Nachrichtenausstellerbzw. -absender,X, + 17,MP-ID Absender,SG2,NAD,3039,00008,,,MP-ID,X, + 18,MP-ID Absender,SG2,NAD,3055,00008,9,,GS1,X, + 19,MP-ID Absender,SG2,NAD,3055,,332,,"DE, DVGW Service &Consult GmbH",X, + 20,Ansprechpartner,SG3,,,,,,,Kann, + 21,Ansprechpartner,SG3,CTA,,00009,,,,Muss, + 22,Ansprechpartner,SG3,CTA,3139,00009,IC,,Informationskontakt,X, + 23,Ansprechpartner,SG3,CTA,3412,00009,,,Name vom Ansprechpartner,X, + 24,Kommunikationsverbindung,SG3,COM,,00010,,,,Muss, + 25,Kommunikationsverbindung,SG3,COM,3148,00010,,,Nummer / Adresse,X, + 26,Kommunikationsverbindung,SG3,COM,3155,00010,EM,,Elektronische Post,X [1P0..1], + 27,Kommunikationsverbindung,SG3,COM,3155,,FX,,Telefax,X [1P0..1], + 28,Kommunikationsverbindung,SG3,COM,3155,,TE,,Telefon,X [1P0..1], + 29,Kommunikationsverbindung,SG3,COM,3155,,AJ,,weiteres Telefon,X [1P0..1], + 30,Kommunikationsverbindung,SG3,COM,3155,,AL,,Handy,X [1P0..1], + 31,MP-ID Empfänger,SG2,,,,,,,Muss, + 32,MP-ID Empfänger,SG2,NAD,,00011,,,,Muss, + 33,MP-ID Empfänger,SG2,NAD,3035,00011,MR,,Nachrichtenempfänger,X, + 34,MP-ID Empfänger,SG2,NAD,3039,00011,,,MP-ID,X, + 35,MP-ID Empfänger,SG2,NAD,3055,00011,9,,GS1,X, + 36,MP-ID Empfänger,SG2,NAD,3055,,332,,"DE, DVGW Service &Consult GmbH",X, + 37,Vorgang,SG4,,,,,,,Muss, + 38,Vorgang,SG4,IDE,,00012,,,,Muss, + 39,Vorgang,SG4,IDE,7495,00012,24,,Transaktion,X, + 40,Vorgang,SG4,IDE,7402,00012,,,Vorgangsnummer,X, + 41,Beginn zum,SG4,DTM,,00015,,,,Muss, + 42,Beginn zum,SG4,DTM,2005,00015,92,,Datum Vertragsbeginn,X, + 43,Beginn zum,SG4,DTM,2380,00015,,,"Datum oder Uhrzeit oderZeitspanne, Wert",X [UB2], + 44,Beginn zum,SG4,DTM,2379,00015,303,,CCYYMMDDHHMMZZZ,X, + 45,"Änderung zum, Gültigkeit, Beginndatum",SG4,DTM,,00018,,,,Muss, + 46,"Änderung zum, Gültigkeit, Beginndatum",SG4,DTM,2005,00018,157,,"Gültigkeit, Beginndatum",X, + 47,"Änderung zum, Gültigkeit, Beginndatum",SG4,DTM,2380,00018,,,"Datum oder Uhrzeit oderZeitspanne, Wert",X [UB2], + 48,"Änderung zum, Gültigkeit, Beginndatum",SG4,DTM,2379,00018,303,,CCYYMMDDHHMMZZZ,X, + 49,Transaktionsgrund,SG4,STS,,00026,,,,Muss [2061],[2061] Segment bzw. Segmentgruppe ist genau einmal je SG4 IDE (Vorgang) anzugeben + 50,Transaktionsgrund,SG4,STS,9015,00026,7,,Transaktionsgrund,X, + 51,Transaktionsgrund,SG4,STS,9013,00026,ZE8,,Änderung vom MSB mitAbhängigkeiten,X, + 52,Status der Antwort,SG4,STS,,00028,,,,,[249] Innerhalb eines SG4 IDE müssen alle DE1131 der SG4 STS+E01 den identischen Wert enthalten + 53,Status der Antwort,SG4,STS,9015,00028,E01,,Status der Antwort,, + 54,Status der Antwort,SG4,STS,9013,00028,,,Code des Prüfschritts,, + 55,Status der Antwort,SG4,STS,1131,00028,G_0026,,Codeliste Gas Nr.G_0026,, + 56,Status der Antwort,SG4,STS,1131,,G_0027,,Codeliste Gas Nr.G_0027,,"[5] Wenn MP-ID in SG2 NAD+MS (Nachrichtenabsender) in der Rolle LF + [98] Wenn MP-ID in SG2 NAD+MS (Nachrichtenabsender) in der Rolle NB" + 57,Meldepunkt,SG5,,,,,,,Muss [2061],[2061] Segment bzw. Segmentgruppe ist genau einmal je SG4 IDE (Vorgang) anzugeben + 58,Meldepunkt,SG5,LOC,,00035,,,,Muss, + 59,Meldepunkt,SG5,LOC,3227,00035,172,,Meldepunkt,X, + 60,Meldepunkt,SG5,LOC,3225,00035,,,Identifikator,X [951],[951] Format: Zählpunktbezeichnung + 61,Prüfidentifikator,SG6,,,,,,,Muss, + 62,Prüfidentifikator,SG6,RFF,,00037,,,,Muss, + 63,Prüfidentifikator,SG6,RFF,1153,00037,Z13,,Prüfidentifikator,X, + 64,Prüfidentifikator,SG6,RFF,1154,00037,44116,,SDÄ Gas / Änderung vomMSB an NB,, + 65,Prüfidentifikator,SG6,RFF,1154,,44117,,SDÄ Gas / Änderung vomMSB NB an LF,X, + 66,Prüfidentifikator,SG6,RFF,1154,,44119,,SDÄ Gas / Antwort aufÄnderung vom MSB AGan AF,, + 67,Referenz Vorgangsnummer (aus Anfragenachricht),SG6,,,,,,,, + 68,Referenz Vorgangsnummer (aus Anfragenachricht),SG6,RFF,,00038,,,,, + 69,Referenz Vorgangsnummer (aus Anfragenachricht),SG6,RFF,1153,00038,TN,,Transaktions-,, + 70,Referenz Vorgangsnummer (aus Anfragenachricht),SG6,RFF,1154,00038,,,Vorgangsnummer,, + 71,Zähleinrichtungsdaten,SG8,,,,,,,Muss [530],"[530] Hinweis: Es sind alle an dem Meldepunkt vorhandenen Daten, die mit dieser Segmentgruppe übermittelt werden und zum Datum „Änderung zum“ Gültigkeit haben, anzugeben. Dies kann zur Folge haben, dass Segmentgruppen bzw. Segmente zu wiederholen sind" + 72,Zähleinrichtungsdaten,SG8,SEQ,,00088,,,,Muss, + 73,Zähleinrichtungsdaten,SG8,SEQ,1229,00088,Z03,,Zähleinrichtungsdaten,X, + 74,Referenz auf die ID einer Messlokation,SG8,RFF,,00089,,,,Muss, + 75,Referenz auf die ID einer Messlokation,SG8,RFF,1153,00089,Z19,,Messlokation,X, + 76,Referenz auf die ID einer Messlokation,SG8,RFF,1154,00089,,,ID einer Messlokation,X [951],[951] Format: Zählpunktbezeichnung + 77,Zählertyp,SG10,,,,,,,Muss, + 78,Zählertyp,SG10,CCI,,00090,,,,Muss, + 79,Zählertyp,SG10,CCI,7037,00090,E13,,Zählertyp,X, + 80,Zählertyp,SG10,CAV,,00091,,,,Muss, + 81,Zählertyp,SG10,CAV,7111,00091,NMG,,neue MesseinrichtungGas nach MsbG,X, + 82,Zählertyp,SG10,CAV,7111,,DKZ,,Drehkolbengaszähler,X, + 83,Zählertyp,SG10,CAV,7111,,BGZ,,Balgengaszähler,X, + 84,Zählertyp,SG10,CAV,7111,,TRZ,,Turbinenradgaszähler,X, + 85,Zählertyp,SG10,CAV,7111,,UGZ,,Ultraschallgaszähler,X, + 86,Zählertyp,SG10,CAV,7111,,WGZ,,Wirbelgaszähler,X, + 87,Zählertyp,SG10,CAV,7111,,EHZ,,elektronischerHaushaltszähler,X, + 88,Zählertyp,SG10,CAV,7111,,IVA,,Individuelle Abstimmung(Sonderausstattung),X, + 89,Zählergröße,SG10,CAV,,00092,,,,Muss, + 90,Zählergröße,SG10,CAV,7110,00092,G10,,Gaszähler G10,X, + 91,Zählergröße,SG10,CAV,7110,,G100,,Gaszähler G100,X, + 92,Zählergröße,SG10,CAV,7110,,G1000,,Gaszähler G1000,X, + 93,Zählergröße,SG10,CAV,7110,,G10000,,Gaszähler G10000,X, + 94,Zählergröße,SG10,CAV,7110,,G12500,,Gaszähler G12500,X, + 95,Zählergröße,SG10,CAV,7110,,G16,,Gaszähler G16,X, + 96,Zählergröße,SG10,CAV,7110,,G160,,Gaszähler G160,X, + 97,Zählergröße,SG10,CAV,7110,,G1600,,Gaszähler G1600,X, + 98,Zählergröße,SG10,CAV,7110,,G16000G2.5,,Gaszähler G16000Gaszähler G2.5,XX, + 99,Zählergröße,SG10,CAV,7110,,G25,,Gaszähler G25,X, + 100,Zählergröße,SG10,CAV,7110,,G250,,Gaszähler G250,X, + 101,Zählergröße,SG10,CAV,7110,,G2500,,Gaszähler G2500,X, + 102,Zählergröße,SG10,CAV,7110,,G350,,Gaszähler G350,X, + 103,Zählergröße,SG10,CAV,7110,,G4,,Gaszähler G4,X, + 104,Zählergröße,SG10,CAV,7110,,G40,,Gaszähler G40,X, + 105,Zählergröße,SG10,CAV,7110,,G400,,Gaszähler G400,X, + 106,Zählergröße,SG10,CAV,7110,,G4000,,Gaszähler G4000,X, + 107,Zählergröße,SG10,CAV,7110,,G6,,Gaszähler G6,X, + 108,Zählergröße,SG10,CAV,7110,,G65,,Gaszähler G65,X, + 109,Zählergröße,SG10,CAV,7110,,G650,,Gaszähler G650,X, + 110,Zählergröße,SG10,CAV,7110,,G6500,,Gaszähler G6500,X, + 111,Identifikation / Nummer des Gerätes,SG10,CAV,,00093,,,,Muss, + 112,Identifikation / Nummer des Gerätes,SG10,CAV,7111,00093,Z30,,Gerätenummer,X, + 113,Identifikation / Nummer des Gerätes,SG10,CAV,7110,00093,,,Gerätenummer,X, + 114,Art der Volumenerfassung,SG10,CAV,,00094,,,,,[166] Wenn vorhanden + 115,Art der Volumenerfassung,SG10,CAV,7111,00094,ZC0,,Art derVolumenerfassung,, + 116,Art der Volumenerfassung,SG10,CAV,7110,00094,Z16,,Hochfrequenzsonde,, + 117,Befestigungsart Zähleinrichtung,SG10,,,,,,,, + 118,Befestigungsart Zähleinrichtung,SG10,CCI,,00095,,,,, + 119,Befestigungsart Zähleinrichtung,SG10,CCI,7037,00095,Z28,,BefestigungsartZähleinrichtung,, + 120,Befestigungsart Zähleinrichtung,SG10,CAV,,00096,,,,, + 121,Befestigungsart Zähleinrichtung,SG10,CAV,7111,00096,Z31,,Einstutzen-Zähler,, + 122,Messwerterfassung an der Zähleinrichtung,SG10,,,,,,,Muss, + 123,Messwerterfassung an der Zähleinrichtung,SG10,CCI,,00097,,,,Muss, + 124,Messwerterfassung an der Zähleinrichtung,SG10,CCI,7037,00097,E12,,Messwerterfassung ander Zähleinrichtung,X, + 125,Messwerterfassung an der Zähleinrichtung,SG10,CAV,,00098,,,,Muss, + 126,Messwerterfassung an der Zähleinrichtung,SG10,CAV,7111,00098,AMR,,fernauslesbare Zähler,X, + 127,Messwerterfassung an der Zähleinrichtung,SG10,CAV,7111,,MMR,,manuell ausgeleseneZähler,X, + 128,Messdatenregistriergeräted aten,SG8,,,,,,,Soll [133] ∧[530],"[133] Wenn an der übermittelten Marktlokation / Messlokation vorhanden + [530] Hinweis: Es sind alle an dem Meldepunkt vorhandenen Daten, die mit dieser Segmentgruppe übermittelt werden und zum Datum „Änderung zum“ Gültigkeit haben, anzugeben. Dies kann zur Folge haben, dass Segmentgruppen bzw. Segmente zu wiederholen sind" + 129,Messdatenregistriergeräted aten,SG8,SEQ,,00099,,,,Muss, + 130,Messdatenregistriergeräted aten,SG8,SEQ,1229,00099,Z50,,Messdatenregistriergerätedaten,X, + 131,Messdatenregistriergerät,SG10,,,,,,,Muss, + 132,Messdatenregistriergerät,SG10,CCI,,00101,,,,Muss, + 133,Messdatenregistriergerät,SG10,CCI,7037,00101,E13,,Zählertyp,X, + 134,Identifikation / Nummer des Gerätes,SG10,CAV,,00102,,,,Muss, + 135,Identifikation / Nummer des Gerätes,SG10,CAV,7111,00102,Z30,,Gerätenummer,X, + 136,Identifikation / Nummer des Gerätes,SG10,CAV,7110,00102,,,Gerätenummer,X, + 137,Art der Volumenerfassung,SG10,CAV,,00103,,,,,[166] Wenn vorhanden + 138,Art der Volumenerfassung,SG10,CAV,7111,00103,ZC0,,Art derVolumenerfassung,, + 139,Art der Volumenerfassung,SG10,CAV,7110,00103,Z16,,Hochfrequenzsonde,, + 140,Mengenumwerterdaten,SG8,,,,,,,Soll [133] ∧[530],"[133] Wenn an der übermittelten Marktlokation / Messlokation vorhanden + [530] Hinweis: Es sind alle an dem Meldepunkt vorhandenen Daten, die mit dieser Segmentgruppe übermittelt werden und zum Datum „Änderung zum“ Gültigkeit haben, anzugeben. Dies kann zur Folge haben, dass Segmentgruppen bzw. Segmente zu wiederholen sind" + 141,Mengenumwerterdaten,SG8,SEQ,,00104,,,,Muss, + 142,Mengenumwerterdaten,SG8,SEQ,1229,00104,Z09,,Mengenumwerter-Daten,X, + 143,Referenz auf die Gerätenummer,SG8,RFF,,00105,,,,Muss, + 144,Referenz auf die Gerätenummer,SG8,RFF,1153,00105,MG,,Gerätenummer desZählers,X, + 145,Referenz auf die Gerätenummer,SG8,RFF,1154,00105,,,Gerätenummer,X, + 146,Mengenumwerter,SG10,,,,,,,Muss, + 147,Mengenumwerter,SG10,CCI,,00106,,,,Muss, + 148,Mengenumwerter,SG10,CCI,7037,00106,Z64,,Mengenumwerter,X, + 149,Identifikation / Nummer des Gerätes,SG10,CAV,,00107,,,,Muss, + 150,Identifikation / Nummer des Gerätes,SG10,CAV,7111,00107,Z30,,Gerätenummer,X, + 151,Identifikation / Nummer des Gerätes,SG10,CAV,7110,00107,,,Gerätenummer,X, + 152,Mengenumwertertyp,SG10,CAV,,00108,,,,Muss, + 153,Mengenumwertertyp,SG10,CAV,7111,00108,DMU,,Dichtemengenumwerter,X, + 154,Mengenumwertertyp,SG10,CAV,7111,,TMU,,Temperaturmengenumwerter,X, + 155,Mengenumwertertyp,SG10,CAV,7111,,ZMU,,Zustandsmengenumwerter,X, + 156,Art der Volumenerfassung,SG10,CAV,,00109,,,,,[166] Wenn vorhanden + 157,Art der Volumenerfassung,SG10,CAV,7111,00109,ZC0,,Art derVolumenerfassung,, + 158,Art der Volumenerfassung,SG10,CAV,7110,00109,Z17,,Kennlinienkorrektur,, + 159,Art der Volumenerfassung,SG10,CAV,7110,,Z18,,Schleichmengenunterdrückung,, + 160,OBIS-Daten der Zähleinrichtung / Mengenumwerter,SG8,,,,,,,Muss [530]∧ [654] ∧([2287] ∨[2353]),"[530] Hinweis: Es sind alle an dem Meldepunkt vorhandenen Daten, die mit dieser Segmentgruppe übermittelt werden und zum Datum „Änderung zum“ Gültigkeit haben, anzugeben. Dies kann zur Folge haben, dass Segmentgruppen bzw. Segmente zu wiederholen sind + [654] Hinweis: Es sind ausschließlich die Daten zum Meldepunkt anzugeben, die für den in NAD+MR (Nachrichtenempfänger) adressierten Marktpartner relevant ist + [2287] Für jede SEQ+Z03 (Zähleinrichtungsdaten) mindestens einmal anzugeben" + 161,OBIS-Daten der Zähleinrichtung / Mengenumwerter,SG8,SEQ,,00110,,,,Muss, + 162,OBIS-Daten der Zähleinrichtung / Mengenumwerter,SG8,SEQ,1229,00110,Z20,,OBIS-Daten derZähleinrichtung,X, + 163,Referenz auf die Gerätenummer,SG8,RFF,,00111,,,,Muss [655],[655] Hinweis: Wenn ein Zähler an einen Mengenumwerter angeschlossen ist werden an dem Zähler keine OBIS-Kennzahlen angegeben Hier gibt es nur OBIS Kennzahlen vom Mengenumwerter   + 164,Referenz auf die Gerätenummer,SG8,RFF,1153,00111,MG,,Gerätenummer desZählers,X [442], + 165,Referenz auf die Gerätenummer,SG8,RFF,1153,,Z11,,Gerätenummer desMengenumwerters,X,[442] Wenn in keinem SG8+SEQ+Z09 Mengenumwerterdaten das RFF+MG (Referenz auf die Gerätenummer) der in diesem RFF DE1154 genannte Gerätenummer des Zählers vorhanden ist + 166,Referenz auf die Gerätenummer,SG8,RFF,1154,00111,,,Gerätenummer,X, + 167,Referenz auf die ID einer Messlokation,SG8,RFF,,00112,,,,Muss, + 168,Referenz auf die ID einer Messlokation,SG8,RFF,1153,00112,Z19,,Messlokation,X, + 169,Referenz auf die ID einer Messlokation,SG8,RFF,1154,00112,,,ID einer Messlokation,X [951],[951] Format: Zählpunktbezeichnung + 170,OBIS-Kennzahl der Zähleinrichtung / Mengenumwerter,SG8,PIA,,00113,,,,Muss, + 171,OBIS-Kennzahl der Zähleinrichtung / Mengenumwerter,SG8,PIA,4347,00113,5,,Produktidentifikation,X, + 172,OBIS-Kennzahl der Zähleinrichtung / Mengenumwerter,SG8,PIA,7140,00113,,,OBIS-Kennzahl derZähleinrichtung,X [324],[324] Es sind alle OBIS- Kennzahlen gem. EDI@Energy Codeliste + 173,OBIS-Kennzahl der Zähleinrichtung / Mengenumwerter,SG8,PIA,7143,00113,SRW,,OBIS-Kennzahl,X, + 174,Wertegranularität,SG10,,,,,,,Muss [274],[274] Wenn in derselben SG8 SEQ+Z20 (OBIS- Daten der Zähleinrichtung / Mengenumwerter) das PIA+5+7-b?:3.0.0 / 7- b?:6.0.0 / 7-b?:3.1.0 / 7-b?:6.1.0 / 7-b?:3.2.0 / 7-b?:6.2.0 / 7-b?:13.2.0 / 7-b?:16.2.0 / 7-b?:1.0.0 / 7-b?:2.0.0 / 7-b?:4.0.0 / 7-b?:5.0.0 / 7-b?:11.2.0 / 7-b?:12.2.0 / 7-b?:14.2.0 / 7-b?:15.2.0 vorhanden + 175,Wertegranularität,SG10,CCI,,00114,,,,Muss, + 176,Wertegranularität,SG10,CCI,7037,00114,ZE4,,Wertegranularität,X, + 177,Wertegranularität,SG10,CAV,,00115,,,,Muss, + 178,Wertegranularität,SG10,CAV,7111,00115,ZD9,,Jährlich,X, + 179,Wertegranularität,SG10,CAV,7111,,ZE8,,Halbjährlich,X, + 180,Wertegranularität,SG10,CAV,7111,,ZE9,,Quartalsweise,X, + 181,Wertegranularität,SG10,CAV,7111,,ZB7,,Monatlich,X, + 182,Vor- und Nachkommastellen des Zählwerks,SG10,,,,,,,Muss [274],[274] Wenn in derselben SG8 SEQ+Z20 (OBIS- Daten der Zähleinrichtung / Mengenumwerter) das PIA+5+7-b?:3.0.0 / 7- b?:6.0.0 / 7-b?:3.1.0 / 7-b?:6.1.0 / 7-b?:3.2.0 / + 183,Vor- und Nachkommastellen des Zählwerks,SG10,CCI,,00116,,,,Muss, + 184,Vor- und Nachkommastellen des Zählwerks,SG10,CCI,7059,00116,11,,Produkt,X, + 185,Vor- und Nachkommastellen des Zählwerks,SG10,CCI,7037,00116,Z33,,Vor- undNachkommastellen desZählwerkes,X, + 186,Vor- und Nachkommastellen des Zählwerks,SG10,CAV,,00117,,,,Muss, + 187,Vor- und Nachkommastellen des Zählwerks,SG10,CAV,7110,00117,,,Angabe der Vorkommastelle,X, + 188,Vor- und Nachkommastellen des Zählwerks,SG10,CAV,7110,00117,,,Angabe der Nachkommastelle,X, + 189,Bezeichnung des Zählwerks auf dem Gerät,SG10,,,,,,,Muss [123]∧ [274],"[123] Wenn noch mindestens eine weitere SG8 SEQ+Z20 (OBIS- Daten der Zähleinrichtung / Mengenumwerter) mit dem SG8 RFF+MG / Z11 (Gerätenummer des Zählers / Mengenumwerters) auf die gleiche Identifikation/Nummer des Gerätes referenziert + [274] Wenn in derselben SG8 SEQ+Z20 (OBIS- Daten der Zähleinrichtung / Mengenumwerter) das PIA+5+7-b?:3.0.0 / 7- b?:6.0.0 / 7-b?:3.1.0 / 7-b?:6.1.0 / 7-b?:3.2.0 / 7-b?:6.2.0 / 7-b?:13.2.0 / 7-b?:16.2.0 / 7-b?:1.0.0 / 7-b?:2.0.0 / 7-b?:4.0.0 / 7-b?:5.0.0 / 7-b?:11.2.0 / 7-b?:12.2.0 / 7-b?:14.2.0 / 7-b?:15.2.0 vorhanden" + 190,Bezeichnung des Zählwerks auf dem Gerät,SG10,CCI,,00118,,,,Muss, + 191,Bezeichnung des Zählwerks auf dem Gerät,SG10,CCI,7037,00118,Z63,,Lokale Kennzeichnung zuKontrollzwecken,X, + 192,Bezeichnung des Zählwerks auf dem Gerät,SG10,CCI,7036,00118,,,Bezeichnung des Zählwerks aufdem Gerät,X, + 193,Kommunikationseinrichtun gsdaten,SG8,,,,,,,Muss [2119]Soll [133] ∧[530],"[133] Wenn an der übermittelten Marktlokation / Messlokation vorhanden + [530] Hinweis: Es sind alle an dem Meldepunkt vorhandenen Daten, die mit dieser Segmentgruppe übermittelt werden und zum Datum „Änderung zum“ Gültigkeit haben, anzugeben. Dies kann zur Folge haben, dass Segmentgruppen bzw. Segmente zu wiederholen sind + [2119] Je SG8 SEQ+Z13 (Smartmeter-Gateway) ist genau einmal die Segmentgruppe anzugeben" + 194,Kommunikationseinrichtun gsdaten,SG8,SEQ,,00119,,,,Muss, + 195,Kommunikationseinrichtun gsdaten,SG8,SEQ,1229,00119,Z05,,Kommunikationseinrichtungsdaten,X, + 196,Referenz auf die Gerätenummer,SG8,RFF,,00120,,,,Muss, + 197,Referenz auf die Gerätenummer,SG8,RFF,1153,00120,MG,,Gerätenummer desZählers,X, + 198,Referenz auf die Gerätenummer,SG8,RFF,1154,00120,,,Gerätenummer,X, + 199,Kommunikationseinrichtun g,SG10,,,,,,,Muss, + 200,Kommunikationseinrichtun g,SG10,CCI,,00121,,,,Muss, + 201,Kommunikationseinrichtun g,SG10,CCI,7037,00121,Z26,,Kommunikationseinrichtung,X, + 202,Identifikation / Nummer des Gerätes,SG10,CAV,,00122,,,,Muss, + 203,Identifikation / Nummer des Gerätes,SG10,CAV,7111,00122,Z30,,Gerätenummer,X, + 204,Identifikation / Nummer des Gerätes,SG10,CAV,7110,00122,,,Gerätenummer,X, + 205,Kommunikationseinrichtun gstyp,SG10,CAV,,00123,,,,Muss, + 206,Kommunikationseinrichtun gstyp,SG10,CAV,7111,00123,GSM,,GSM/GPRS/UMTS-Kom.-Einr.,X, + 207,Kommunikationseinrichtun gstyp,SG10,CAV,7111,,ETH,,Ethernet-Kom.-Einricht.LAN/WLAN,X, + 208,Kommunikationseinrichtun gstyp,SG10,CAV,7111,,PLC,,PLC-Kom.-Einrichtung,X, + 209,Kommunikationseinrichtun gstyp,SG10,CAV,7111,,PST,,Festnetz-Kom.-Einricht.TAE,X, + 210,Kommunikationseinrichtun gstyp,SG10,CAV,7111,,DSL,,DSL-Kom.Einr.,X, + 211,Kommunikationseinrichtun gstyp,SG10,CAV,7111,,LTE,,LTE-Kom.-Einr.,X, + 212,Smartmeter-Gateway,SG8,,,,,,,Soll [130],[130] Wenn an Messlokation vorhanden + 213,Smartmeter-Gateway,SG8,SEQ,,00124,,,,Muss, + 214,Smartmeter-Gateway,SG8,SEQ,1229,00124,Z13,,Smartmeter-Gateway,X, + 215,Smartmeter-Gateway,SG10,,,,,,,Muss, + 216,Smartmeter-Gateway,SG10,CCI,,00125,,,,Muss, + 217,Smartmeter-Gateway,SG10,CCI,7037,00125,Z75,,Smartmeter-Gateway,X, + 218,Identifikation / Nummer des Gerätes,SG10,CAV,,00126,,,,Muss, + 219,Identifikation / Nummer des Gerätes,SG10,CAV,7111,00126,Z30,,Gerätenummer,X, + 220,Identifikation / Nummer des Gerätes,SG10,CAV,7110,00126,,,Gerätenummer,X [952],[952] Format: Gerätenummer nach DIN 43863-5 + 221,Nachrichten-Endesegment,,UNT,,00149,,,,Muss, + 222,Nachrichten-Endesegment,,UNT,0074,00149,,,Anzahl der Segmente in einerNachricht,X, + 223,Nachrichten-Endesegment,,UNT,0062,00149,,,Nachrichten-Referenznummer,X, + + ''' +# --- +# name: TestCli.test_kohlrahbi_cli_with_valid_arguments[44138] + ''' + ,Segmentname,Segmentgruppe,Segment,Datenelement,Segment ID,Code,Qualifier,Beschreibung,Bedingungsausdruck,Bedingung + 0,Nachrichten-Kopfsegment,,UNH,,00003,,,,Muss, + 1,Nachrichten-Kopfsegment,,UNH,0062,00003,,,Nachrichten-Referenznummer,X, + 2,Nachrichten-Kopfsegment,,UNH,0065,00003,UTILMD,,Netzanschluss-Stammdaten,X, + 3,Nachrichten-Kopfsegment,,UNH,0052,00003,D,,Entwurfs-Version,X, + 4,Nachrichten-Kopfsegment,,UNH,0054,00003,11A,,Ausgabe 2011 - A,X, + 5,Nachrichten-Kopfsegment,,UNH,0051,00003,UN,,UN/CEFACT,X, + 6,Nachrichten-Kopfsegment,,UNH,0057,00003,Versionsnummer derzugrundeliegendenBDEW-Nachrichtenbeschreibung,,G1.0a,X, + 7,Beginn der Nachricht,,BGM,,00004,,,,Muss, + 8,Beginn der Nachricht,,BGM,1001,00004,E03,,Änderungsmeldungen,X, + 9,Beginn der Nachricht,,BGM,1004,00004,,,Dokumentennummer,X, + 10,Nachrichtendatum,,DTM,,00005,,,,Muss, + 11,Nachrichtendatum,,DTM,2005,00005,137,,Dokumenten-/Nachrichtendatum/-zeit,X, + 12,Nachrichtendatum,,DTM,2380,00005,,,"Datum oder Uhrzeit oderZeitspanne, Wert",X [931] [494],"[494] Das hier genannte Datum muss der Zeitpunkt sein, zu dem das Dokument erstellt wurde, oder ein Zeitpunkt, der davor liegt + [931] Format: ZZZ = +00" + 13,Nachrichtendatum,,DTM,2379,00005,303,,CCYYMMDDHHMMZZZ,X, + 14,MP-ID Absender,SG2,,,,,,,Muss, + 15,MP-ID Absender,SG2,NAD,,00008,,,,Muss, + 16,MP-ID Absender,SG2,NAD,3035,00008,MS,,Dokumenten-/Nachrichtenausstellerbzw. -absender,X, + 17,MP-ID Absender,SG2,NAD,3039,00008,,,MP-ID,X, + 18,MP-ID Absender,SG2,NAD,3055,00008,9,,GS1,X, + 19,MP-ID Absender,SG2,NAD,3055,,332,,"DE, DVGW Service &Consult GmbH",X, + 20,Ansprechpartner,SG3,,,,,,,Kann, + 21,Ansprechpartner,SG3,CTA,,00009,,,,Muss, + 22,Ansprechpartner,SG3,CTA,3139,00009,IC,,Informationskontakt,X, + 23,Ansprechpartner,SG3,CTA,3412,00009,,,Name vom Ansprechpartner,X, + 24,Kommunikationsverbindung,SG3,COM,,00010,,,,Muss, + 25,Kommunikationsverbindung,SG3,COM,3148,00010,,,Nummer / Adresse,X, + 26,Kommunikationsverbindung,SG3,COM,3155,00010,EM,,Elektronische Post,X [1P0..1], + 27,MP-ID Empfänger,SG2,,,,,,,Muss, + 28,MP-ID Empfänger,SG2,NAD,,00011,,,,Muss, + 29,MP-ID Empfänger,SG2,NAD,3035,00011,MR,,Nachrichtenempfänger,X, + 30,MP-ID Empfänger,SG2,NAD,3039,00011,,,MP-ID,X, + 31,MP-ID Empfänger,SG2,NAD,3055,00011,9,,GS1,X, + 32,MP-ID Empfänger,SG2,NAD,3055,,332,,"DE, DVGW Service &Consult GmbH",X, + 33,Vorgang,SG4,,,,,,,Muss, + 34,Vorgang,SG4,IDE,,00012,,,,Muss, + 35,Vorgang,SG4,IDE,7495,00012,24,,Transaktion,X, + 36,Vorgang,SG4,IDE,7402,00012,,,Vorgangsnummer,X, + 37,Beginn zum,SG4,DTM,,00015,,,,Muss, + 38,Beginn zum,SG4,DTM,2005,00015,92,,Datum Vertragsbeginn,X, + 39,Beginn zum,SG4,DTM,2380,00015,,,"Datum oder Uhrzeit oderZeitspanne, Wert",X [UB2] ∧ [528],[528] Hinweis: Es ist das Datum/ Daten aus der Anfrage zu verwenden + 40,Beginn zum,SG4,DTM,2379,00015,303,,CCYYMMDDHHMMZZZ,X, + 41,"Änderung zum, Gültigkeit, Beginndatum",SG4,DTM,,00018,,,,Muss, + 42,"Änderung zum, Gültigkeit, Beginndatum",SG4,DTM,2005,00018,157,,"Gültigkeit, Beginndatum",X, + 43,"Änderung zum, Gültigkeit, Beginndatum",SG4,DTM,2380,00018,,,"Datum oder Uhrzeit oderZeitspanne, Wert",X [UB2] ∧ [528],[528] Hinweis: Es ist das Datum/ Daten aus der Anfrage zu verwenden + 44,"Änderung zum, Gültigkeit, Beginndatum",SG4,DTM,2379,00018,303,,CCYYMMDDHHMMZZZ,X, + 45,Transaktionsgrund,SG4,STS,,00026,,,,Muss [2061],[2061] Segment bzw. Segmentgruppe ist genau einmal je SG4 IDE (Vorgang) anzugeben + 46,Transaktionsgrund,SG4,STS,9015,00026,7,,Transaktionsgrund,X, + 47,Transaktionsgrund,SG4,STS,9013,00026,ZF3,,Nicht bila.rel. Anfrage anLF,X, + 48,Status der Antwort,SG4,STS,,00028,,,,Muss [249],[249] Innerhalb eines SG4 IDE müssen alle DE1131 der SG4 STS+E01 den identischen Wert enthalten + 49,Status der Antwort,SG4,STS,9015,00028,E01,,Status der Antwort,X, + 50,Status der Antwort,SG4,STS,9013,00028,,,Code des Prüfschritts,X, + 51,Status der Antwort,SG4,STS,1131,00028,G_0040,,Codeliste Gas Nr.G_0040,X, + 52,Meldepunkt,SG5,,,,,,,Muss [2061],[2061] Segment bzw. Segmentgruppe ist genau einmal je SG4 IDE (Vorgang) anzugeben + 53,Meldepunkt,SG5,LOC,,00035,,,,Muss, + 54,Meldepunkt,SG5,LOC,3227,00035,172,,Meldepunkt,X, + 55,Meldepunkt,SG5,LOC,3225,00035,,,Identifikator,X [950],[950] Format: Marktlokations-ID + 56,Prüfidentifikator,SG6,,,,,,,Muss, + 57,Prüfidentifikator,SG6,RFF,,00037,,,,Muss, + 58,Prüfidentifikator,SG6,RFF,1153,00037,Z13,,Prüfidentifikator,X, + 59,Prüfidentifikator,SG6,RFF,1154,00037,44137,,SDÄ Gas / Nicht bila.rel.Anfrage an LF NB[Berechtigt] an LF,, + 60,Prüfidentifikator,SG6,RFF,1154,,44138,,SDÄ Gas / Antwort aufnicht bila.rel. Anfrage anLF LF an NB,X, + 61,Referenz Vorgangsnummer (aus Anfragenachricht),SG6,,,,,,,Muss, + 62,Referenz Vorgangsnummer (aus Anfragenachricht),SG6,RFF,,00038,,,,Muss, + 63,Referenz Vorgangsnummer (aus Anfragenachricht),SG6,RFF,1153,00038,TN,,Transaktions-Referenznummer,X, + 64,Referenz Vorgangsnummer (aus Anfragenachricht),SG6,RFF,1154,00038,,,Vorgangsnummer,X, + 65,Referenz auf die ID der Marktlokation für Termine der Marktlokation,SG6,,,,,,,Soll [202] ∧[336],"[202] Wenn SG4 STS+E01+ZG2 (Status der Antwort: Gültiges Ergebnis nach der Datenprüfung) vorhanden + [336] Wenn in Änderungsmeldung gefüllt" + 66,Referenz auf die ID der Marktlokation für Termine der Marktlokation,SG6,RFF,,00041,,,,Muss [636],[636] Hinweis: Dieses RFF klassifiziert mit einem Code im DE1153 die in derselben Segmentgruppe enthaltenen DTM zu einem Markt- bzw. Messlokation relevanten Inhalt + 67,Referenz auf die ID der Marktlokation für Termine der Marktlokation,SG6,RFF,1153,00041,Z18,,Marktlokation,X, + 68,Referenz auf die ID der Marktlokation für Termine der Marktlokation,SG6,RFF,1154,00041,,,ID der Marktlokation,X [950],[950] Format: Marktlokations-ID + 69,Abrechnungsintervall des LF,SG6,DTM,,00043,,,,Muss, + 70,Abrechnungsintervall des LF,SG6,DTM,2005,00043,Z20,,Abrechnungsintervall desLF,X, + 71,Abrechnungsintervall des LF,SG6,DTM,2380,00043,,,"Datum oder Uhrzeit oderZeitspanne, Wert",X, + 72,Abrechnungsintervall des LF,SG6,DTM,2379,00043,802,,Monat,X, + 73,Daten der Marktlokation,SG8,,,,,,,Soll [202] ∧[336],"[92] Wenn Wert innerhalb SG bzw. Segment geändert wird + [202] Wenn SG4 STS+E01+ZG2 (Status der Antwort: Gültiges Ergebnis nach der Datenprüfung) vorhanden + [336] Wenn in Änderungsmeldung gefüllt" + 74,Daten der Marktlokation,SG8,SEQ,,00049,,,,Muss, + 75,Daten der Marktlokation,SG8,SEQ,1229,00049,Z01,,Daten der Marktlokation,X, + 76,Gruppenzuordnung (nach EnWG) ,SG10,,,,,,,Muss, + 77,Gruppenzuordnung (nach EnWG) ,SG10,CCI,,00060,,,,Muss, + 78,Gruppenzuordnung (nach EnWG) ,SG10,CCI,7037,00060,Z15,,Haushaltskunde gem.EnWG,X, + 79,Gruppenzuordnung (nach EnWG) ,SG10,CCI,7037,,Z18,,Kein Haushaltskundegem. EnWG,X, + 80,Kunde des Lieferanten,SG12,,,,,,,Soll [202] ∧[336],"[202] Wenn SG4 STS+E01+ZG2 (Status der Antwort: Gültiges Ergebnis nach der Datenprüfung) vorhanden + [336] Wenn in Änderungsmeldung gefüllt" + 81,Kunde des Lieferanten,SG12,NAD,,00134,,,,Muss, + 82,Kunde des Lieferanten,SG12,NAD,3035,00134,Z09,,Kunde des LF,X, + 83,Kunde des Lieferanten,SG12,NAD,3036,00134,,,Name,X, + 84,Kunde des Lieferanten,SG12,NAD,3045,00134,Z01,,Struktur vonPersonennamen,X, + 85,Kunde des Lieferanten,SG12,NAD,3045,,Z02,,Struktur derFirmenbezeichnung,X, + 86,Kundennummer beim Lieferanten,SG12,RFF,,00135,,,,Kann, + 87,Kundennummer beim Lieferanten,SG12,RFF,1153,00135,AVC,,Kundennummer beimLieferanten,X, + 88,Kundennummer beim Lieferanten,SG12,RFF,1154,00135,,,Kundennummer beim LF,X, + 89,Korrespondenzanschrift des Kunden des Lieferanten,SG12,,,,,,,Soll [202] ∧[336],"[202] Wenn SG4 STS+E01+ZG2 (Status der Antwort: Gültiges Ergebnis nach der Datenprüfung) vorhanden + [336] Wenn in Änderungsmeldung gefüllt" + 90,Korrespondenzanschrift des Kunden des Lieferanten,SG12,NAD,,00137,,,,Muss, + 91,Korrespondenzanschrift des Kunden des Lieferanten,SG12,NAD,3035,00137,Z04,,Korrespondenzanschriftdes Kunden des LF,X, + 92,Korrespondenzanschrift des Kunden des Lieferanten,SG12,NAD,3036,00137,,,Name,X, + 93,Korrespondenzanschrift des Kunden des Lieferanten,SG12,NAD,3045,00137,Z01,,Struktur vonPersonennamen,X, + 94,Korrespondenzanschrift des Kunden des Lieferanten,SG12,NAD,3045,,Z02,,Struktur derFirmenbezeichnung,X, + 95,Korrespondenzanschrift des Kunden des Lieferanten,SG12,NAD,3042,00137,,,Straße und Hausnummer oderPostfach,X, + 96,Korrespondenzanschrift des Kunden des Lieferanten,SG12,NAD,3164,00137,,,Ort,X, + 97,Korrespondenzanschrift des Kunden des Lieferanten,SG12,NAD,3251,00137,,,Postleitzahl,M [268]S [166],"[166] Wenn vorhanden + [268] Wenn der Code im DE3207 in der ""EDI@Energy Codeliste der europäischen Ländercodes"" in der Spalte ""PLZ vorhanden"" ein ""X"" aufgeführt ist" + 98,Korrespondenzanschrift des Kunden des Lieferanten,SG12,NAD,3207,00137,,,"Ländername, Code",X, + 99,Nachrichten-Endesegment,,UNT,,00149,,,,Muss, + 100,Nachrichten-Endesegment,,UNT,0074,00149,,,Anzahl der Segmente in einerNachricht,X, + 101,Nachrichten-Endesegment,,UNT,0062,00149,,,Nachrichten-Referenznummer,X, + + ''' +# --- +# name: TestCli.test_kohlrahbi_cli_with_valid_arguments[44140] + ''' + ,Segmentname,Segmentgruppe,Segment,Datenelement,Segment ID,Code,Qualifier,Beschreibung,Bedingungsausdruck,Bedingung + 0,Nachrichten-Kopfsegment,,UNH,,00003,,,,Muss, + 1,Nachrichten-Kopfsegment,,UNH,0062,00003,,,Nachrichten-Referenznummer,X, + 2,Nachrichten-Kopfsegment,,UNH,0065,00003,UTILMD,,Netzanschluss-Stammdaten,X, + 3,Nachrichten-Kopfsegment,,UNH,0052,00003,D,,Entwurfs-Version,X, + 4,Nachrichten-Kopfsegment,,UNH,0054,00003,11A,,Ausgabe 2011 - A,X, + 5,Nachrichten-Kopfsegment,,UNH,0051,00003,UN,,UN/CEFACT,X, + 6,Nachrichten-Kopfsegment,,UNH,0057,00003,Versionsnummer derzugrundeliegendenBDEW-Nachrichtenbeschreibung,,G1.0a,X, + 7,Beginn der Nachricht,,BGM,,00004,,,,Muss, + 8,Beginn der Nachricht,,BGM,1001,00004,E03,,Änderungsmeldungen,X, + 9,Beginn der Nachricht,,BGM,1004,00004,,,Dokumentennummer,X, + 10,Nachrichtendatum,,DTM,,00005,,,,Muss, + 11,Nachrichtendatum,,DTM,2005,00005,137,,Dokumenten-/Nachrichtendatum/-zeit,X, + 12,Nachrichtendatum,,DTM,2380,00005,,,"Datum oder Uhrzeit oderZeitspanne, Wert",X [931][494],"[494] Das hier genannte Datum muss der Zeitpunkt sein, zu dem das Dokument erstellt wurde, oder ein Zeitpunkt, der davor liegt + [931] Format: ZZZ = +00" + 13,Nachrichtendatum,,DTM,2379,00005,303,,CCYYMMDDHHMMZZZ,X, + 14,MP-ID Absender,SG2,,,,,,,Muss, + 15,MP-ID Absender,SG2,NAD,,00008,,,,Muss, + 16,MP-ID Absender,SG2,NAD,3035,00008,MS,,Dokumenten-/Nachrichtenausstellerbzw. -absender,X, + 17,MP-ID Absender,SG2,NAD,3039,00008,,,MP-ID,X, + 18,MP-ID Absender,SG2,NAD,3055,00008,9,,GS1,X, + 19,MP-ID Absender,SG2,NAD,3055,,332,,"DE, DVGW Service &Consult GmbH",X, + 20,Ansprechpartner,SG3,,,,,,,Kann, + 21,Ansprechpartner,SG3,CTA,,00009,,,,Muss, + 22,Ansprechpartner,SG3,CTA,3139,00009,IC,,Informationskontakt,X, + 23,Ansprechpartner,SG3,CTA,3412,00009,,,Name vom Ansprechpartner,X, + 24,Kommunikationsverbindung,SG3,COM,,00010,,,,Muss, + 25,Kommunikationsverbindung,SG3,COM,3148,00010,,,Nummer / Adresse,X, + 26,Kommunikationsverbindung,SG3,COM,3155,00010,EM,,Elektronische Post,X [1P0..1], + 27,Kommunikationsverbindung,SG3,COM,3155,,FX,,Telefax,X [1P0..1], + 28,Kommunikationsverbindung,SG3,COM,3155,,TE,,Telefon,X [1P0..1], + 29,Kommunikationsverbindung,SG3,COM,3155,,AJ,,weiteres Telefon,X [1P0..1], + 30,Kommunikationsverbindung,SG3,COM,3155,,AL,,Handy,X [1P0..1], + 31,MP-ID Empfänger,SG2,,,,,,,Muss, + 32,MP-ID Empfänger,SG2,NAD,,00011,,,,Muss, + 33,MP-ID Empfänger,SG2,NAD,3035,00011,MR,,Nachrichtenempfänger,X, + 34,MP-ID Empfänger,SG2,NAD,3039,00011,,,MP-ID,X, + 35,MP-ID Empfänger,SG2,NAD,3055,00011,9,,GS1,X, + 36,MP-ID Empfänger,SG2,NAD,3055,,332,,"DE, DVGW Service &Consult GmbH",X, + 37,Vorgang,SG4,,,,,,,Muss, + 38,Vorgang,SG4,IDE,,00012,,,,Muss, + 39,Vorgang,SG4,IDE,7495,00012,24,,Transaktion,X, + 40,Vorgang,SG4,IDE,7402,00012,,,Vorgangsnummer,X, + 41,Beginn zum,SG4,DTM,,00015,,,,Muss, + 42,Beginn zum,SG4,DTM,2005,00015,92,,Datum Vertragsbeginn,X, + 43,Beginn zum,SG4,DTM,2380,00015,,,"Datum oder Uhrzeit oderZeitspanne, Wert",X [UB2],[528] Hinweis: Es ist das Datum/ Daten aus der Anfrage zu verwenden + 44,Beginn zum,SG4,DTM,2379,00015,303,,CCYYMMDDHHMMZZZ,X, + 45,"Änderung zum, Gültigkeit, Beginndatum",SG4,DTM,,00018,,,,Muss, + 46,"Änderung zum, Gültigkeit, Beginndatum",SG4,DTM,2005,00018,157,,"Gültigkeit, Beginndatum",X, + 47,"Änderung zum, Gültigkeit, Beginndatum",SG4,DTM,2380,00018,,,"Datum oder Uhrzeit oderZeitspanne, Wert",X [UB2],[528] Hinweis: Es ist das Datum/ Daten aus der Anfrage zu verwenden + 48,"Änderung zum, Gültigkeit, Beginndatum",SG4,DTM,2379,00018,303,,CCYYMMDDHHMMZZZ,X, + 49,Transaktionsgrund,SG4,STS,,00026,,,,Muss [2061],[2061] Segment bzw. Segmentgruppe ist genau einmal je SG4 IDE (Vorgang) anzugeben + 50,Transaktionsgrund,SG4,STS,9015,00026,7,,Transaktionsgrund,X, + 51,Transaktionsgrund,SG4,STS,9013,00026,ZF4,,Nicht bila.rel. Anfrage anNB,X, + 52,Status der Antwort,SG4,STS,,00028,,,,,[249] Innerhalb eines SG4 IDE müssen alle + 53,Status der Antwort,SG4,STS,9015,00028,E01,,Status der Antwort,, + 54,Status der Antwort,SG4,STS,9013,00028,,,Code des Prüfschritts,, + 55,Status der Antwort,SG4,STS,1131,00028,G_0031,,Codeliste Gas Nr.G_0031,, + 56,Status der Antwort,SG4,STS,1131,,G_0069,,Codeliste Gas Nr.G_0069,,"[4] Wenn MP-ID in SG2 NAD+MR (Nachrichtenempfänger) in der Rolle LF + [241] Wenn MP-ID in SG2 NAD+MR (Nachrichtenempfänger) in der Rolle MSB" + 57,Meldepunkt,SG5,,,,,,,Muss [2061],[2061] Segment bzw. Segmentgruppe ist genau einmal je SG4 IDE (Vorgang) anzugeben + 58,Meldepunkt,SG5,LOC,,00035,,,,Muss, + 59,Meldepunkt,SG5,LOC,3227,00035,172,,Meldepunkt,X, + 60,Meldepunkt,SG5,LOC,3225,00035,,,Identifikator,X [951],"[951] Format: Zählpunktbezeichnung + [953] Format: Marktlokations-ID oder Zählpunktbezeichnung" + 61,Prüfidentifikator,SG6,,,,,,,Muss, + 62,Prüfidentifikator,SG6,RFF,,00037,,,,Muss, + 63,Prüfidentifikator,SG6,RFF,1153,00037,Z13,,Prüfidentifikator,X, + 64,Prüfidentifikator,SG6,RFF,1154,00037,44139,,SDÄ Gas / Nicht bila.rel.Anfrage an NB LF an NB,, + 65,Prüfidentifikator,SG6,RFF,1154,,44140,,SDÄ Gas / Nicht bila.rel.Anfrage an NB MSB anNB,X, + 66,Prüfidentifikator,SG6,RFF,1154,,44142,,SDÄ Gas / Antwort aufnicht bila.rel. Anfrage anNB NB an AF,, + 67,Referenz Vorgangsnummer (aus Anfragenachricht),SG6,,,,,,,, + 68,Referenz Vorgangsnummer (aus Anfragenachricht),SG6,RFF,,00038,,,,, + 69,Referenz Vorgangsnummer (aus Anfragenachricht),SG6,RFF,1153,00038,TN,,Transaktions-Referenznummer,, + 70,Referenz Vorgangsnummer (aus Anfragenachricht),SG6,RFF,1154,00038,,,Vorgangsnummer,, + 71,Referenz auf die ID der Marktlokation für Termine der Marktlokation,SG6,,,,,,,,[202] Wenn SG4 + 72,Referenz auf die ID der Marktlokation für Termine der Marktlokation,SG6,RFF,,00041,,,,,[636] Hinweis: Dieses RFF klassifiziert mit einem Code im DE1153 die in derselben Segmentgruppe enthaltenen DTM zu einem Markt- bzw. Messlokation relevanten Inhalt + 73,Referenz auf die ID der Marktlokation für Termine der Marktlokation,SG6,RFF,1153,00041,Z18,,Marktlokation,, + 74,Referenz auf die ID der Marktlokation für Termine der Marktlokation,SG6,RFF,1154,00041,,,ID der Marktlokation,,[950] Format: Marktlokations-ID + 75,Start des Abrechnungsjahrs bei Marktlokationen mit Jahresleistungspreis,SG6,DTM,,00042,,,,,"[202] Wenn SG4 STS+E01+ZG2 (Status der Antwort: Gültiges Ergebnis nach der Datenprüfung) vorhanden + [336] Wenn in Änderungsmeldung gefüllt" + 76,Start des Abrechnungsjahrs bei Marktlokationen mit Jahresleistungspreis,SG6,DTM,2005,00042,155,,"Rechnungsperiode,Beginndatum",, + 77,Start des Abrechnungsjahrs bei Marktlokationen mit Jahresleistungspreis,SG6,DTM,2380,00042,,,"Datum oder Uhrzeit oderZeitspanne, Wert",, + 78,Start des Abrechnungsjahrs bei Marktlokationen mit Jahresleistungspreis,SG6,DTM,2379,00042,303,,CCYYMMDDHHMMZZZ,, + 79,Termin der Netznutzungsabrechnung,SG6,DTM,,00044,,,,,"[202] Wenn SG4 STS+E01+ZG2 (Status der Antwort: Gültiges Ergebnis nach der Datenprüfung) vorhanden + [336] Wenn in Änderungsmeldung gefüllt" + 80,Termin der Netznutzungsabrechnung,SG6,DTM,2005,00044,Z21,,Termin derNetznutzungsabrechnung,, + 81,Termin der Netznutzungsabrechnung,SG6,DTM,2380,00044,,,"Datum oder Uhrzeit oderZeitspanne, Wert",, + 82,Termin der Netznutzungsabrechnung,SG6,DTM,2379,00044,106,,MMDD,, + 83,Termin der Netznutzungsabrechnung,SG6,DTM,2379,,104,,MMWW-MMWW,, + 84,Nächste Netznutzungsabrechnung,SG6,DTM,,00045,,,,,"[24] Wenn SG6 DTM+Z21 (Termin der Netznutzungsabrechnun g) vorhanden + [230] Sich ergebendes Datum/ bzw. Endedatum des Turnuszeitraums aus DTM+Z21 (Termin der Netznutzungsabrechnun g) und DTM+Z09 (Nächste Netznutzungsabrechnun g) muss >= DTM+92 (Beginn zum) sein" + 85,Nächste Netznutzungsabrechnung,SG6,DTM,2005,00045,Z09,,NächsteNetznutzungsabrechnung,, + 86,Nächste Netznutzungsabrechnung,SG6,DTM,2380,00045,,,"Datum oder Uhrzeit oderZeitspanne, Wert",, + 87,Nächste Netznutzungsabrechnung,SG6,DTM,2379,00045,602,,CCYY,, + 88,Netznutzungsabrechnungsi ntervall des NB,SG6,DTM,,00046,,,,,"[202] Wenn SG4 STS+E01+ZG2 (Status der Antwort: Gültiges Ergebnis nach der Datenprüfung) vorhanden + [336] Wenn in Änderungsmeldung gefüllt" + 89,Netznutzungsabrechnungsi ntervall des NB,SG6,DTM,2005,00046,Z22,,Netznutzungsabrechnungs- bzw.Einspeisevergütungsintervall des NB,,[504] Hinweis: Der Code Z22 wird auch in der Sparte Strom genutzt. Der Verweis auf den Einspeisevergütungsinter vall ist in der Sparte Gas nicht relevant. + 90,Netznutzungsabrechnungsi ntervall des NB,SG6,DTM,2380,00046,,,"Datum oder Uhrzeit oderZeitspanne, Wert",, + 91,Netznutzungsabrechnungsi ntervall des NB,SG6,DTM,2379,00046,802,,Monat,, + 92,Referenz auf die ID der Messlokation für Termine der Messlokation,SG6,,,,,,,Kann,"[202] Wenn SG4 STS+E01+ZG2 (Status der Antwort: Gültiges Ergebnis nach der Datenprüfung) vorhanden + [336] Wenn in Änderungsmeldung gefüllt" + 93,Referenz auf die ID der Messlokation für Termine der Messlokation,SG6,RFF,,00047,,,,Muss [636],[636] Hinweis: Dieses RFF klassifiziert mit einem Code im DE1153 die in derselben Segmentgruppe enthaltenen DTM zu einem Markt- bzw. Messlokation relevanten Inhalt + 94,Referenz auf die ID der Messlokation für Termine der Messlokation,SG6,RFF,1153,00047,Z19,,Messlokation,X, + 95,Referenz auf die ID der Messlokation für Termine der Messlokation,SG6,RFF,1154,00047,,,ID der Messlokation,X [951],[951] Format: Zählpunktbezeichnung + 96,Turnusablesung des NB,SG6,DTM,,00048,,,,Kann,"[202] Wenn SG4 STS+E01+ZG2 (Status der Antwort: Gültiges Ergebnis nach der Datenprüfung) vorhanden + [336] Wenn in Änderungsmeldung gefüllt" + 97,Turnusablesung des NB,SG6,DTM,2005,00048,752,,Turnusablesung,X, + 98,Turnusablesung des NB,SG6,DTM,2380,00048,,,"Datum oder Uhrzeit oderZeitspanne, Wert",X, + 99,Turnusablesung des NB,SG6,DTM,2379,00048,104,,MMWW-MMWW,X, + 100,Turnusablesung des NB,SG6,DTM,2379,,106,,MMDD,X, + 101,Daten der Marktlokation,SG8,,,,,,,,[92] Wenn Wert innerhalb SG bzw. Segment geändert wird + 102,Daten der Marktlokation,SG8,SEQ,,00049,,,,, + 103,Daten der Marktlokation,SG8,SEQ,1229,00049,Z01,,Daten der Marktlokation,, + 104,Marktgebiet,SG10,,,,,,,,[202] Wenn SG4 + 105,Marktgebiet,SG10,CCI,,00055,,,,, + 106,Marktgebiet,SG10,CCI,7059,00055,Z21,,Marktgebiet,, + 107,Marktgebiet,SG10,CCI,7037,00055,,,Marktgebiet,, + 108,Druckebene der Marktlokation,SG10,,,,,,,,"[202] Wenn SG4 STS+E01+ZG2 (Status der Antwort: Gültiges Ergebnis nach der Datenprüfung) vorhanden + [336] Wenn in Änderungsmeldung gefüllt" + 109,Druckebene der Marktlokation,SG10,CCI,,00056,,,,, + 110,Druckebene der Marktlokation,SG10,CCI,7037,00056,Y01,,Druckebene derMarktlokation,, + 111,Druckebene der Marktlokation,SG10,CAV,,00057,,,,, + 112,Druckebene der Marktlokation,SG10,CAV,7111,00057,Y01,,Hochdruck,, + 113,Druckebene der Marktlokation,SG10,CAV,7111,,Y02,,Mitteldruck,, + 114,Druckebene der Marktlokation,SG10,CAV,7111,,Y03,,Niederdruck,, + 115,Bereits ausgetauschte Prognosegrundlage der Marktlokation,SG10,,,,,,,, + 116,Bereits ausgetauschte Prognosegrundlage der Marktlokation,SG10,CCI,,00059,,,,, + 117,Bereits ausgetauschte Prognosegrundlage der Marktlokation,SG10,CCI,7037,00059,ZB0,,Prognose auf Basis vonWerten gültig,, + 118,Bereits ausgetauschte Prognosegrundlage der Marktlokation,SG10,CCI,7037,,ZB1,,Prognose auf Basis vonProfilen gültig,, + 119,Netznutzung,SG10,,,,,,,,[202] Wenn SG4 STS+E01+ZG2 (Status der Antwort: Gültiges Ergebnis nach der Datenprüfung) vorhanden + 120,Netznutzung,SG10,CCI,,00062,,,,, + 121,Netznutzung,SG10,CCI,7037,00062,Z88,,Netznutzung,, + 122,Netznutzungsvertrag,SG10,CAV,,00063,,,,, + 123,Netznutzungsvertrag,SG10,CAV,7111,00063,Z74,,Netznutzungsvertrag,, + 124,Netznutzungsvertrag,SG10,CAV,7110,00063,Z08,,Direkter Vertragzwischen Kunden und NB,, + 125,Netznutzungsvertrag,SG10,CAV,7110,,Z09,,Vertrag zwischenLieferanten und NB,, + 126,Zahlung der Netznutzung,SG10,CAV,,00064,,,,, + 127,Zahlung der Netznutzung,SG10,CAV,7111,00064,Z73,,Zahlung der Netznutzung,, + 128,Zahlung der Netznutzung,SG10,CAV,7110,00064,Z10,,Kunde,, + 129,Zahlung der Netznutzung,SG10,CAV,7110,,Z11,,Lieferant,,[216] Wenn CCI+++Z88 (Netznutzung) CAV+Z74:::Z08 (Netznutzungsvertrag: Direkter Vertrag zwischen Kunden und NB) vorhanden + 130,Netznutzungsabrechnungsv ariante,SG10,CAV,,00065,,,,, + 131,Netznutzungsabrechnungsv ariante,SG10,CAV,7111,00065,ZB1,,Netznutzungsabrechnungsvariante,, + 132,Netznutzungsabrechnungsv ariante,SG10,CAV,7110,00065,Z14,,Arbeitspreis/Grundpreis,, + 133,Netznutzungsabrechnungsv ariante,SG10,CAV,7110,,Z15,,Arbeitspreis/Leistungspreis,, + 134,OBIS-Daten der Marktlokation,SG8,,,,,,,,"[25] Wenn der Meldepunkt im SG5 LOC+172 (Meldepunkt) DE3225 das Format der Marktlokations-ID hat + [202] Wenn SG4 STS+E01+ZG2 (Status der Antwort: Gültiges Ergebnis nach der Datenprüfung) vorhanden + [336] Wenn in Änderungsmeldung gefüllt" + 135,OBIS-Daten der Marktlokation,SG8,SEQ,,00067,,,,, + 136,OBIS-Daten der Marktlokation,SG8,SEQ,1229,00067,Z02,,OBIS-Daten derMarktlokation,, + 137,OBIS-Kennzahl der Marktlokation,SG8,PIA,,00068,,,,, + 138,OBIS-Kennzahl der Marktlokation,SG8,PIA,4347,00068,5,,Produktidentifikation,, + 139,OBIS-Kennzahl der Marktlokation,SG8,PIA,7140,00068,,,OBIS-Kennzahl der Marktlokation,,"[315] Es sind alle OBISKennzahlen gem. EDI@Energy Codeliste der OBIS-Kennzahlen und Medien für den deutschen Energiemarkt Kap. 4 anzugeben welche an der Marktlokation erforderlich sind, dabei muss der Mindestumfang aus Kap. 4.6 eingehalten werden. Der Mindestumfang der OBIS-Kennzahlen ergibt sich aus den genannten Messprodukt-Codes dem Kap. 5.2 des Dokumentes ""Codeliste der Konfigurationen""" + 140,OBIS-Kennzahl der Marktlokation,SG8,PIA,7143,00068,SRW,,OBIS-Kennzahl,, + 141,Wertegranularität,SG10,,,,,,,,[257] Wenn in derselben SG8 SEQ+Z02 (OBIS- Daten der Marktlokation) das PIA+5+7-0?:33.86.0 vorhanden + 142,Wertegranularität,SG10,CCI,,00069,,,,, + 143,Wertegranularität,SG10,CCI,7037,00069,ZE4,,Wertegranularität,, + 144,Wertegranularität,SG10,CAV,,00070,,,,, + 145,Wertegranularität,SG10,CAV,7111,00070,ZD9,,Jährlich,, + 146,Wertegranularität,SG10,CAV,7111,,ZE8,,Halbjährlich,, + 147,Wertegranularität,SG10,CAV,7111,,ZE9,,Quartalsweise,, + 148,Wertegranularität,SG10,CAV,7111,,ZB7,,Monatlich,, + 149,Konzessionsabgabedaten,SG8,,,,,,,,"[25] Wenn der Meldepunkt im SG5 LOC+172 (Meldepunkt) DE3225 das Format der Marktlokations-ID hat + [202] Wenn SG4 STS+E01+ZG2 (Status der Antwort: Gültiges Ergebnis nach der Datenprüfung) vorhanden + [336] Wenn in Änderungsmeldung gefüllt" + 150,Konzessionsabgabedaten,SG8,SEQ,,00071,,,,, + 151,Konzessionsabgabedaten,SG8,SEQ,1229,00071,Z07,,Konzessionsabgabedaten,, + 152,Referenz auf die OBIS- Kennzahl der Marktlokation,SG8,RFF,,00072,,,,, + 153,Referenz auf die OBIS- Kennzahl der Marktlokation,SG8,RFF,1153,00072,Z10,,OBIS-Kennzahl,, + 154,Referenz auf die OBIS- Kennzahl der Marktlokation,SG8,RFF,1154,00072,,,OBIS-Kennzahl,, + 155,Zuordnung Konzessionsabgabe,SG10,,,,,,,, + 156,Zuordnung Konzessionsabgabe,SG10,CCI,,00073,,,,, + 157,Zuordnung Konzessionsabgabe,SG10,CCI,7037,00073,Z08,,Konzessionsabgabe,, + 158,Konzessionsabgabe,SG10,CAV,,00074,,,,, + 159,Konzessionsabgabe,SG10,CAV,7111,00074,KAS,,"für allekonzessionsvertraglichenSonderregelungen, dienicht in die Systematikder KAV eingegliedertsind",, + 160,Konzessionsabgabe,SG10,CAV,7111,,SA,,"Sondervertragskunden <1 kV nach § 2 (7) und > 1kV, Preis nach § 2 (3) (fürStrom 0,11 ct/kWh undfür Gas 0,03 ct/kWh)",, + 161,Konzessionsabgabe,SG10,CAV,7111,,SAS,,"Kennzeichnung, dass ein",, + 162,Konzessionsabgabe,SG10,CAV,7110,00074,,,Konzessionsabgabe in Euro/kWh,,"[128] Wenn SG10 CAV+TAS/ TKS/ SAS/ KAS vorhanden + [902] Format: Möglicher Wert: ≥ 0 + [912] Format: max. 6 Nachkommastellen" + 163,Konzessionsabgabe,SG10,CAV,7110,00074,,,Gebührenkategorie derKonzessionsabgabe,,[219] Wenn an Marktlokation vorhanden + 164,Gemeinderabatt,SG8,,,,,,,,"[25] Wenn der Meldepunkt im SG5 LOC+172 (Meldepunkt) DE3225 das Format der Marktlokations-ID hat + [202] Wenn SG4 STS+E01+ZG2 (Status der Antwort: Gültiges Ergebnis nach der Datenprüfung) vorhanden + [336] Wenn in Änderungsmeldung gefüllt" + 165,Gemeinderabatt,SG8,SEQ,,00075,,,,, + 166,Gemeinderabatt,SG8,SEQ,1229,00075,Z12,,Gemeinderabatt,, + 167,Gemeinderabatt,SG9,,,,,,,, + 168,Gemeinderabatt,SG9,QTY,,00076,,,,, + 169,Gemeinderabatt,SG9,QTY,6063,00076,Z16,,Gemeinderabatt,, + 170,Gemeinderabatt,SG9,QTY,6060,00076,,,Menge,,"[902] Format: Möglicher Wert: ≥ 0 + [930] Format: max. 2 Nachkommastellen + [938] Format: Möglicher Wert: <= 10" + 171,Gemeinderabatt,SG9,QTY,6411,00076,P1,,Prozent,, + 172,Daten der Messlokation,SG8,,,,,,,Kann [345],"[202] Wenn SG4 STS+E01+ZG2 (Status der Antwort: Gültiges Ergebnis nach der Datenprüfung) vorhanden + [336] Wenn in Änderungsmeldung gefüllt + [345] Wenn 33-stelliger Meldepunkt im SG5 LOC+172 (Meldepunkt) vorhanden" + 173,Daten der Messlokation,SG8,SEQ,,00077,,,,Muss, + 174,Daten der Messlokation,SG8,SEQ,1229,00077,Z18,,Daten der Messlokation,X, + 175,Referenz auf die ID der Messlokation,SG8,RFF,,00078,,,,Muss, + 176,Referenz auf die ID der Messlokation,SG8,RFF,1153,00078,Z19,,Messlokation,X, + 177,Referenz auf die ID der Messlokation,SG8,RFF,1154,00078,,,ID der Messlokation,X [951],[951] Format: Zählpunktbezeichnung + 178,Zugeordnete Marktpartner,SG10,,,,,,,Kann,"[202] Wenn SG4 STS+E01+ZG2 (Status der Antwort: Gültiges Ergebnis nach der Datenprüfung) vorhanden + [336] Wenn in Änderungsmeldung gefüllt" + 179,Zugeordnete Marktpartner,SG10,CCI,,00079,,,,Muss, + 180,Zugeordnete Marktpartner,SG10,CCI,7037,00079,ZB3,,ZugeordneterMarktpartner,X, + 181,Messstellenbetreiber,SG10,CAV,,00080,,,,Muss, + 182,Messstellenbetreiber,SG10,CAV,7111,00080,Z91,,MSB,X, + 183,Messstellenbetreiber,SG10,CAV,1131,00080,,,MP-ID,X, + 184,Messstellenbetreiber,SG10,CAV,7110,00080,Z19,,Auf vertraglicherGrundlage gegenüberAnschlussnutzer /Anschlussnehmer,X, + 185,Messstellenbetreiber,SG10,CAV,7110,,Z20,,In der Ausübung derWeiterverpflichtungdurch den gMSB,X, + 186,Grundzuständiger Messstellenbetreiber,SG10,CAV,,00081,,,,Muss, + 187,Grundzuständiger Messstellenbetreiber,SG10,CAV,7111,00081,ZF0,,gMSB,X, + 188,Grundzuständiger Messstellenbetreiber,SG10,CAV,1131,00081,,,MP-ID,X, + 189,Gasqualität,SG10,,,,,,,Kann,"[202] Wenn SG4 STS+E01+ZG2 (Status der Antwort: Gültiges Ergebnis nach der Datenprüfung) vorhanden + [336] Wenn in Änderungsmeldung gefüllt" + 190,Gasqualität,SG10,CCI,,00083,,,,Muss, + 191,Gasqualität,SG10,CCI,7037,00083,Y02,,Gasqualität,X, + 192,Gasqualität,SG10,CAV,,00084,,,,Muss, + 193,Gasqualität,SG10,CAV,7111,00084,Y04,,H-Gas,X, + 194,Gasqualität,SG10,CAV,7111,,Y05,,L-Gas,X, + 195,Kunde des Netzbetreibers,SG12,,,,,,,Kann [558],[558] Hinweis: Diese Information kann freiwillig ausgetauscht werden + 196,Kunde des Netzbetreibers,SG12,NAD,,00140,,,,Muss, + 197,Kunde des Netzbetreibers,SG12,NAD,3035,00140,Z25,,Kunde des NB,X, + 198,Kunde des Netzbetreibers,SG12,NAD,3036,00140,,,Name,X, + 199,Kunde des Netzbetreibers,SG12,NAD,3045,00140,Z01,,Struktur vonPersonennamen,X, + 200,Kunde des Netzbetreibers,SG12,NAD,3045,,Z02,,Struktur derFirmenbezeichnung,X, + 201,Korrespondenzanschrift des Kunde des Netzbetreibers,SG12,,,,,,,Kann [558],[558] Hinweis: Diese Information kann + 202,Korrespondenzanschrift des Kunde des Netzbetreibers,SG12,NAD,,00141,,,,Muss, + 203,Korrespondenzanschrift des Kunde des Netzbetreibers,SG12,NAD,3035,00141,Z26,,Korrespondenzanschriftdes Kunden des NB,X, + 204,Korrespondenzanschrift des Kunde des Netzbetreibers,SG12,NAD,3036,00141,,,Name,X, + 205,Korrespondenzanschrift des Kunde des Netzbetreibers,SG12,NAD,3045,00141,Z01,,Struktur vonPersonennamen,X, + 206,Korrespondenzanschrift des Kunde des Netzbetreibers,SG12,NAD,3045,,Z02,,Struktur derFirmenbezeichnung,X, + 207,Korrespondenzanschrift des Kunde des Netzbetreibers,SG12,NAD,3042,00141,,,Straße und Hausnummer oderPostfach,X, + 208,Korrespondenzanschrift des Kunde des Netzbetreibers,SG12,NAD,3164,00141,,,Ort,X, + 209,Korrespondenzanschrift des Kunde des Netzbetreibers,SG12,NAD,3251,00141,,,Postleitzahl,M [268]S [166],"[166] Wenn vorhanden + [268] Wenn der Code im DE3207 in der ""EDI@Energy Codeliste der europäischen Ländercodes"" in der Spalte ""PLZ vorhanden"" ein ""X"" aufgeführt ist" + 210,Korrespondenzanschrift des Kunde des Netzbetreibers,SG12,NAD,3207,00141,,,"Ländername, Code",X, + 211,Netzanschlusseigentümer,SG12,,,,,,,Kann [558],[558] Hinweis: Diese Information kann freiwillig ausgetauscht werden + 212,Netzanschlusseigentümer,SG12,NAD,,00142,,,,Muss, + 213,Netzanschlusseigentümer,SG12,NAD,3035,00142,EO,,Anschlussnehmer,X, + 214,Netzanschlusseigentümer,SG12,NAD,3036,00142,,,Name,X, + 215,Netzanschlusseigentümer,SG12,NAD,3045,00142,Z01,,Struktur vonPersonennamen,X, + 216,Netzanschlusseigentümer,SG12,NAD,3045,,Z02,,Struktur derFirmenbezeichnung,X, + 217,Netzanschlusseigentümer,SG12,NAD,3042,00142,,,Straße und Hausnummer oderPostfach,X, + 218,Netzanschlusseigentümer,SG12,NAD,3164,00142,,,Ort,X, + 219,Netzanschlusseigentümer,SG12,NAD,3251,00142,,,Postleitzahl,M [268]S [166],"[166] Wenn vorhanden + [268] Wenn der Code im DE3207 in der ""EDI@Energy Codeliste der europäischen Ländercodes"" in der Spalte ""PLZ vorhanden"" ein ""X"" aufgeführt ist" + 220,Netzanschlusseigentümer,SG12,NAD,3207,00142,,,"Ländername, Code",Muss, + 221,Hausverwalter,SG12,,,,,,,Kann [558],[558] Hinweis: Diese Information kann freiwillig ausgetauscht + 222,Hausverwalter,SG12,NAD,,00143,,,,Muss, + 223,Hausverwalter,SG12,NAD,3035,00143,DDO,,Location manager,X, + 224,Hausverwalter,SG12,NAD,3036,00143,,,Name,X, + 225,Hausverwalter,SG12,NAD,3045,00143,Z01,,Struktur vonPersonennamen,X, + 226,Hausverwalter,SG12,NAD,3045,,Z02,,Struktur derFirmenbezeichnung,X, + 227,Hausverwalter,SG12,NAD,3042,00143,,,Straße und Hausnummer oderPostfach,X, + 228,Hausverwalter,SG12,NAD,3164,00143,,,Ort,X, + 229,Hausverwalter,SG12,NAD,3251,00143,,,Postleitzahl,M [268]S [166],"[166] Wenn vorhanden + [268] Wenn der Code im DE3207 in der ""EDI@Energy Codeliste der europäischen Ländercodes"" in der Spalte ""PLZ vorhanden"" ein ""X"" aufgeführt ist" + 230,Hausverwalter,SG12,NAD,3207,00143,,,"Ländername, Code",Muss, + 231,Marktlokationsanschrift,SG12,,,,,,,,"[202] Wenn SG4 STS+E01+ZG2 (Status der Antwort: Gültiges Ergebnis nach der Datenprüfung) vorhanden + [336] Wenn in Änderungsmeldung gefüllt" + 232,Marktlokationsanschrift,SG12,NAD,,00145,,,,, + 233,Marktlokationsanschrift,SG12,NAD,3035,00145,DP,,Lieferanschrift,, + 234,Marktlokationsanschrift,SG12,NAD,3124,00145,,,Zusatzinformation zurIdentifizierung,, + 235,Marktlokationsanschrift,SG12,NAD,3042,00145,,,Straße und Hausnummer oderPostfach,,"[166] Wenn vorhanden + [212] Wenn im selben SG12 NAD DE3124 nicht vorhanden" + 236,Marktlokationsanschrift,SG12,NAD,3164,00145,,,Ort,, + 237,Marktlokationsanschrift,SG12,NAD,3251,00145,,,Postleitzahl,, + 238,Marktlokationsanschrift,SG12,NAD,3207,00145,,,"Ländername, Code",, + 239,Nachrichten-Endesegment,,UNT,,00149,,,,Muss, + 240,Nachrichten-Endesegment,,UNT,0074,00149,,,Anzahl der Segmente in einerNachricht,X, + 241,Nachrichten-Endesegment,,UNT,0062,00149,,,Nachrichten-Referenznummer,X, + + ''' +# --- +# name: TestCli.test_kohlrahbi_cli_with_valid_arguments[44148] + ''' + ,Segmentname,Segmentgruppe,Segment,Datenelement,Segment ID,Code,Qualifier,Beschreibung,Bedingungsausdruck,Bedingung + 0,Nachrichten-Kopfsegment,,UNH,,00003,,,,Muss, + 1,Nachrichten-Kopfsegment,,UNH,0062,00003,,,Nachrichten-Referenznummer,X, + 2,Nachrichten-Kopfsegment,,UNH,0065,00003,UTILMD,,Netzanschluss-Stammdaten,X, + 3,Nachrichten-Kopfsegment,,UNH,0052,00003,D,,Entwurfs-Version,X, + 4,Nachrichten-Kopfsegment,,UNH,0054,00003,11A,,Ausgabe 2011 - A,X, + 5,Nachrichten-Kopfsegment,,UNH,0051,00003,UN,,UN/CEFACT,X, + 6,Nachrichten-Kopfsegment,,UNH,0057,00003,Versionsnummer derzugrundeliegendenBDEW-Nachrichtenbeschreibung,,G1.0a,X, + 7,Beginn der Nachricht,,BGM,,00004,,,,Muss, + 8,Beginn der Nachricht,,BGM,1001,00004,E03,,Änderungsmeldungen,X, + 9,Beginn der Nachricht,,BGM,1004,00004,,,Dokumentennummer,X, + 10,Nachrichtendatum,,DTM,,00005,,,,Muss, + 11,Nachrichtendatum,,DTM,2005,00005,137,,Dokumenten-/Nachrichtendatum/-zeit,X, + 12,Nachrichtendatum,,DTM,2380,00005,,,"Datum oder Uhrzeit oderZeitspanne, Wert",X [931][494],"[494] Das hier genannte Datum muss der Zeitpunkt sein, zu dem das Dokument erstellt wurde, oder ein Zeitpunkt, der davor liegt + [931] Format: ZZZ = +00" + 13,Nachrichtendatum,,DTM,2379,00005,303,,CCYYMMDDHHMMZZZ,X, + 14,MP-ID Absender,SG2,,,,,,,Muss, + 15,MP-ID Absender,SG2,NAD,,00008,,,,Muss, + 16,MP-ID Absender,SG2,NAD,3035,00008,MS,,Dokumenten-/Nachrichtenausstellerbzw. -absender,X, + 17,MP-ID Absender,SG2,NAD,3039,00008,,,MP-ID,X, + 18,MP-ID Absender,SG2,NAD,3055,00008,9,,GS1,X, + 19,MP-ID Absender,SG2,NAD,3055,,332,,"DE, DVGW Service &Consult GmbH",X, + 20,Ansprechpartner,SG3,,,,,,,Kann, + 21,Ansprechpartner,SG3,CTA,,00009,,,,Muss, + 22,Ansprechpartner,SG3,CTA,3139,00009,IC,,Informationskontakt,X, + 23,Ansprechpartner,SG3,CTA,3412,00009,,,Name vom Ansprechpartner,X, + 24,Kommunikationsverbindung,SG3,COM,,00010,,,,Muss, + 25,Kommunikationsverbindung,SG3,COM,3148,00010,,,Nummer / Adresse,X, + 26,Kommunikationsverbindung,SG3,COM,3155,00010,EM,,Elektronische Post,X [1P0..1], + 27,Kommunikationsverbindung,SG3,COM,3155,,FX,,Telefax,X [1P0..1], + 28,Kommunikationsverbindung,SG3,COM,3155,,TE,,Telefon,X [1P0..1], + 29,Kommunikationsverbindung,SG3,COM,3155,,AJ,,weiteres Telefon,X [1P0..1], + 30,Kommunikationsverbindung,SG3,COM,3155,,AL,,Handy,X [1P0..1], + 31,MP-ID Empfänger,SG2,,,,,,,Muss, + 32,MP-ID Empfänger,SG2,NAD,,00011,,,,Muss, + 33,MP-ID Empfänger,SG2,NAD,3035,00011,MR,,Nachrichtenempfänger,X, + 34,MP-ID Empfänger,SG2,NAD,3039,00011,,,MP-ID,X, + 35,MP-ID Empfänger,SG2,NAD,3055,00011,9,,GS1,X, + 36,MP-ID Empfänger,SG2,NAD,3055,,332,,"DE, DVGW Service &Consult GmbH",X, + 37,Vorgang,SG4,,,,,,,Muss, + 38,Vorgang,SG4,IDE,,00012,,,,Muss, + 39,Vorgang,SG4,IDE,7495,00012,24,,Transaktion,X, + 40,Vorgang,SG4,IDE,7402,00012,,,Vorgangsnummer,X, + 41,Beginn zum,SG4,DTM,,00015,,,,Muss, + 42,Beginn zum,SG4,DTM,2005,00015,92,,Datum Vertragsbeginn,X, + 43,Beginn zum,SG4,DTM,2380,00015,,,"Datum oder Uhrzeit oderZeitspanne, Wert",X [UB2],[528] Hinweis: Es ist das Datum/ Daten aus der Anfrage zu verwenden + 44,Beginn zum,SG4,DTM,2379,00015,303,,CCYYMMDDHHMMZZZ,X, + 45,"Änderung zum, Gültigkeit, Beginndatum",SG4,DTM,,00018,,,,Muss, + 46,"Änderung zum, Gültigkeit, Beginndatum",SG4,DTM,2005,00018,157,,"Gültigkeit, Beginndatum",X, + 47,"Änderung zum, Gültigkeit, Beginndatum",SG4,DTM,2380,00018,,,"Datum oder Uhrzeit oderZeitspanne, Wert",X [UB2],[528] Hinweis: Es ist das Datum/ Daten aus der Anfrage zu verwenden + 48,"Änderung zum, Gültigkeit, Beginndatum",SG4,DTM,2379,00018,303,,CCYYMMDDHHMMZZZ,X, + 49,Transaktionsgrund,SG4,STS,,00026,,,,Muss [2061],[2061] Segment bzw. Segmentgruppe ist genau einmal je SG4 IDE (Vorgang) anzugeben + 50,Transaktionsgrund,SG4,STS,9015,00026,7,,Transaktionsgrund,X, + 51,Transaktionsgrund,SG4,STS,9013,00026,ZF5,,Anfrage an MSB mit,X, + 52,Status der Antwort,SG4,STS,,00028,,,,,[249] Innerhalb eines SG4 IDE müssen alle DE1131 der SG4 STS+E01 den identischen Wert enthalten + 53,Status der Antwort,SG4,STS,9015,00028,E01,,Status der Antwort,, + 54,Status der Antwort,SG4,STS,9013,00028,,,Code des Prüfschritts,, + 55,Status der Antwort,SG4,STS,1131,00028,G_0044,,Codeliste Gas Nr.G_0044,, + 56,Meldepunkt,SG5,,,,,,,Muss [2061],[2061] Segment bzw. Segmentgruppe ist genau einmal je SG4 IDE (Vorgang) anzugeben + 57,Meldepunkt,SG5,LOC,,00035,,,,Muss, + 58,Meldepunkt,SG5,LOC,3227,00035,172,,Meldepunkt,X, + 59,Meldepunkt,SG5,LOC,3225,00035,,,Identifikator,X [951],[951] Format: Zählpunktbezeichnung + 60,Prüfidentifikator,SG6,,,,,,,Muss, + 61,Prüfidentifikator,SG6,RFF,,00037,,,,Muss, + 62,Prüfidentifikator,SG6,RFF,1153,00037,Z13,,Prüfidentifikator,X, + 63,Prüfidentifikator,SG6,RFF,1154,00037,44147,,SDÄ Gas / Anfrage anMSB mit AbhängigkeitenNB [Verteiler] an MSB,, + 64,Prüfidentifikator,SG6,RFF,1154,,44148,,SDÄ Gas / Anfrage anMSB mit AbhängigkeitenNB [Berechtigt] an MSB,X, + 65,Prüfidentifikator,SG6,RFF,1154,,44149,,SDÄ Gas / Antwort aufAnfrage an MSB mitAbhängigkeiten MSB anNB,, + 66,Referenz Vorgangsnummer (aus Anfragenachricht),SG6,,,,,,,, + 67,Referenz Vorgangsnummer (aus Anfragenachricht),SG6,RFF,,00038,,,,, + 68,Referenz Vorgangsnummer (aus Anfragenachricht),SG6,RFF,1153,00038,TN,,Transaktions-Referenznummer,, + 69,Referenz Vorgangsnummer (aus Anfragenachricht),SG6,RFF,1154,00038,,,Vorgangsnummer,, + 70,Zähleinrichtungsdaten,SG8,,,,,,,Kann,[336] Wenn in Änderungsmeldung gefüllt + 71,Zähleinrichtungsdaten,SG8,SEQ,,00088,,,,Muss, + 72,Zähleinrichtungsdaten,SG8,SEQ,1229,00088,Z03,,Zähleinrichtungsdaten,X, + 73,Referenz auf die ID einer Messlokation,SG8,RFF,,00089,,,,Muss, + 74,Referenz auf die ID einer Messlokation,SG8,RFF,1153,00089,Z19,,Messlokation,X, + 75,Referenz auf die ID einer Messlokation,SG8,RFF,1154,00089,,,ID einer Messlokation,X [951],[951] Format: Zählpunktbezeichnung + 76,Zählertyp,SG10,,,,,,,Muss, + 77,Zählertyp,SG10,CCI,,00090,,,,Muss, + 78,Zählertyp,SG10,CCI,7037,00090,E13,,Zählertyp,X, + 79,Zählertyp,SG10,CAV,,00091,,,,Muss, + 80,Zählertyp,SG10,CAV,7111,00091,NMG,,neue MesseinrichtungGas nach MsbG,X, + 81,Zählertyp,SG10,CAV,7111,,DKZ,,Drehkolbengaszähler,X, + 82,Zählertyp,SG10,CAV,7111,,BGZ,,Balgengaszähler,X, + 83,Zählertyp,SG10,CAV,7111,,TRZ,,Turbinenradgaszähler,X, + 84,Zählertyp,SG10,CAV,7111,,UGZ,,Ultraschallgaszähler,X, + 85,Zählertyp,SG10,CAV,7111,,WGZ,,Wirbelgaszähler,X, + 86,Zählertyp,SG10,CAV,7111,,EHZ,,elektronischerHaushaltszähler,X, + 87,Zählertyp,SG10,CAV,7111,,IVA,,Individuelle Abstimmung(Sonderausstattung),X, + 88,Zählergröße,SG10,CAV,,00092,,,,Muss, + 89,Zählergröße,SG10,CAV,7110,00092,G10,,Gaszähler G10,X, + 90,Zählergröße,SG10,CAV,7110,,G100,,Gaszähler G100,X, + 91,Zählergröße,SG10,CAV,7110,,G1000,,Gaszähler G1000,X, + 92,Zählergröße,SG10,CAV,7110,,G10000,,Gaszähler G10000,X, + 93,Zählergröße,SG10,CAV,7110,,G12500,,Gaszähler G12500,X, + 94,Zählergröße,SG10,CAV,7110,,G16,,Gaszähler G16,X, + 95,Zählergröße,SG10,CAV,7110,,G160,,Gaszähler G160,X, + 96,Zählergröße,SG10,CAV,7110,,G1600,,Gaszähler G1600,X, + 97,Zählergröße,SG10,CAV,7110,,G16000G2.5,,Gaszähler G16000Gaszähler G2.5,XX, + 98,Zählergröße,SG10,CAV,7110,,G25,,Gaszähler G25,X, + 99,Zählergröße,SG10,CAV,7110,,G250,,Gaszähler G250,X, + 100,Zählergröße,SG10,CAV,7110,,G2500,,Gaszähler G2500,X, + 101,Zählergröße,SG10,CAV,7110,,G350,,Gaszähler G350,X, + 102,Zählergröße,SG10,CAV,7110,,G4,,Gaszähler G4,X, + 103,Zählergröße,SG10,CAV,7110,,G40,,Gaszähler G40,X, + 104,Zählergröße,SG10,CAV,7110,,G400,,Gaszähler G400,X, + 105,Zählergröße,SG10,CAV,7110,,G4000,,Gaszähler G4000,X, + 106,Zählergröße,SG10,CAV,7110,,G6,,Gaszähler G6,X, + 107,Zählergröße,SG10,CAV,7110,,G65,,Gaszähler G65,X, + 108,Zählergröße,SG10,CAV,7110,,G650,,Gaszähler G650,X, + 109,Zählergröße,SG10,CAV,7110,,G6500,,Gaszähler G6500,X, + 110,Identifikation / Nummer des Gerätes,SG10,CAV,,00093,,,,Muss, + 111,Identifikation / Nummer des Gerätes,SG10,CAV,7111,00093,Z30,,Gerätenummer,X, + 112,Identifikation / Nummer des Gerätes,SG10,CAV,7110,00093,,,Gerätenummer,X, + 113,Art der Volumenerfassung,SG10,CAV,,00094,,,,Soll [166],[166] Wenn vorhanden + 114,Art der Volumenerfassung,SG10,CAV,7111,00094,ZC0,,Art derVolumenerfassung,X, + 115,Art der Volumenerfassung,SG10,CAV,7110,00094,Z16,,Hochfrequenzsonde,X, + 116,Befestigungsart Zähleinrichtung,SG10,,,,,,,Muss, + 117,Befestigungsart Zähleinrichtung,SG10,CCI,,00095,,,,Muss, + 118,Befestigungsart Zähleinrichtung,SG10,CCI,7037,00095,Z28,,BefestigungsartZähleinrichtung,X, + 119,Befestigungsart Zähleinrichtung,SG10,CAV,,00096,,,,Muss, + 120,Befestigungsart Zähleinrichtung,SG10,CAV,7111,00096,Z31,,Einstutzen-Zähler,X, + 121,Befestigungsart Zähleinrichtung,SG10,CAV,7111,,Z32,,Zweistutzen-Zähler,X, + 122,Messwerterfassung an der Zähleinrichtung,SG10,,,,,,,Muss, + 123,Messwerterfassung an der Zähleinrichtung,SG10,CCI,,00097,,,,Muss, + 124,Messwerterfassung an der Zähleinrichtung,SG10,CCI,7037,00097,E12,,Messwerterfassung ander Zähleinrichtung,X, + 125,Messwerterfassung an der Zähleinrichtung,SG10,CAV,,00098,,,,Muss, + 126,Messwerterfassung an der Zähleinrichtung,SG10,CAV,7111,00098,AMR,,fernauslesbare Zähler,X, + 127,Messwerterfassung an der Zähleinrichtung,SG10,CAV,7111,,MMR,,manuell ausgeleseneZähler,X, + 128,Messdatenregistriergeräted aten,SG8,,,,,,,Kann [345],"[133] Wenn an der übermittelten Marktlokation / Messlokation vorhanden + [336] Wenn in Änderungsmeldung gefüllt + [345] Wenn 33-stelliger Meldepunkt im SG5 LOC+172 (Meldepunkt) vorhanden + [530] Hinweis: Es sind alle an dem Meldepunkt vorhandenen Daten, die mit dieser Segmentgruppe übermittelt werden und zum Datum „Änderung zum“ Gültigkeit haben, anzugeben. Dies kann zur Folge haben, dass Segmentgruppen bzw. Segmente zu wiederholen sind" + 129,Messdatenregistriergeräted aten,SG8,SEQ,,00099,,,,Muss, + 130,Messdatenregistriergeräted aten,SG8,SEQ,1229,00099,Z50,,Messdatenregistriergerätedaten,X, + 131,Messdatenregistriergerät,SG10,,,,,,,Muss, + 132,Messdatenregistriergerät,SG10,CCI,,00101,,,,Muss, + 133,Messdatenregistriergerät,SG10,CCI,7037,00101,E13,,Zählertyp,X, + 134,Identifikation / Nummer des Gerätes,SG10,CAV,,00102,,,,Muss, + 135,Identifikation / Nummer des Gerätes,SG10,CAV,7111,00102,Z30,,Gerätenummer,X, + 136,Identifikation / Nummer des Gerätes,SG10,CAV,7110,00102,,,Gerätenummer,X, + 137,Art der Volumenerfassung,SG10,CAV,,00103,,,,Soll [166],[166] Wenn vorhanden + 138,Art der Volumenerfassung,SG10,CAV,7111,00103,ZC0,,Art derVolumenerfassung,X, + 139,Art der Volumenerfassung,SG10,CAV,7110,00103,Z16,,Hochfrequenzsonde,X, + 140,Mengenumwerterdaten,SG8,,,,,,,Kann [345],"[133] Wenn an der übermittelten Marktlokation / Messlokation vorhanden + [336] Wenn in Änderungsmeldung gefüllt + [345] Wenn 33-stelliger Meldepunkt im SG5 LOC+172 (Meldepunkt) vorhanden + [530] Hinweis: Es sind alle an dem Meldepunkt vorhandenen Daten, die mit dieser Segmentgruppe übermittelt werden und zum Datum „Änderung zum“ Gültigkeit haben, anzugeben. Dies kann zur Folge haben, dass Segmentgruppen bzw. Segmente zu wiederholen sind" + 141,Mengenumwerterdaten,SG8,SEQ,,00104,,,,Muss, + 142,Mengenumwerterdaten,SG8,SEQ,1229,00104,Z09,,Mengenumwerter-Daten,X, + 143,Referenz auf die Gerätenummer,SG8,RFF,,00105,,,,Muss, + 144,Referenz auf die Gerätenummer,SG8,RFF,1153,00105,MG,,Gerätenummer desZählers,X, + 145,Referenz auf die Gerätenummer,SG8,RFF,1154,00105,,,Gerätenummer,X, + 146,Mengenumwerter,SG10,,,,,,,Muss, + 147,Mengenumwerter,SG10,CCI,,00106,,,,Muss, + 148,Mengenumwerter,SG10,CCI,7037,00106,Z64,,Mengenumwerter,X, + 149,Identifikation / Nummer des Gerätes,SG10,CAV,,00107,,,,Muss, + 150,Identifikation / Nummer des Gerätes,SG10,CAV,7111,00107,Z30,,Gerätenummer,X, + 151,Identifikation / Nummer des Gerätes,SG10,CAV,7110,00107,,,Gerätenummer,X, + 152,Mengenumwertertyp,SG10,CAV,,00108,,,,Muss, + 153,Mengenumwertertyp,SG10,CAV,7111,00108,DMU,,Dichtemengenumwerter,X, + 154,Mengenumwertertyp,SG10,CAV,7111,,TMU,,Temperaturmengenumwerter,X, + 155,Mengenumwertertyp,SG10,CAV,7111,,ZMU,,Zustandsmengenumwerter,X, + 156,Art der Volumenerfassung,SG10,CAV,,00109,,,,Soll [166],[166] Wenn vorhanden + 157,Art der Volumenerfassung,SG10,CAV,7111,00109,ZC0,,Art derVolumenerfassung,X, + 158,Art der Volumenerfassung,SG10,CAV,7110,00109,Z17,,Kennlinienkorrektur,X, + 159,Art der Volumenerfassung,SG10,CAV,7110,,Z18,,Schleichmengenunterdrückung,X, + 160,OBIS-Daten der Zähleinrichtung / Mengenumwerter,SG8,,,,,,,Kann,"[336] Wenn in Änderungsmeldung gefüllt + [345] Wenn 33-stelliger Meldepunkt im SG5 LOC+172 (Meldepunkt) vorhanden + [530] Hinweis: Es sind alle an dem Meldepunkt vorhandenen Daten, die mit dieser Segmentgruppe übermittelt werden und zum Datum „Änderung zum“ Gültigkeit haben," + 161,OBIS-Daten der Zähleinrichtung / Mengenumwerter,SG8,SEQ,,00110,,,,Muss, + 162,OBIS-Daten der Zähleinrichtung / Mengenumwerter,SG8,SEQ,1229,00110,Z20,,OBIS-Daten derZähleinrichtung,X, + 163,Referenz auf die Gerätenummer,SG8,RFF,,00111,,,,Muss [655],[655] Hinweis: Wenn ein Zähler an einen Mengenumwerter angeschlossen ist werden an dem Zähler keine OBIS-Kennzahlen angegeben Hier gibt es nur OBIS Kennzahlen vom Mengenumwerter   + 164,Referenz auf die Gerätenummer,SG8,RFF,1153,00111,MG,,Gerätenummer desZählers,X [442], + 165,Referenz auf die Gerätenummer,SG8,RFF,1153,,Z11,,Gerätenummer desMengenumwerters,X,[442] Wenn in keinem SG8+SEQ+Z09 Mengenumwerterdaten das RFF+MG (Referenz auf die Gerätenummer) der in diesem RFF DE1154 genannte Gerätenummer des Zählers vorhanden ist + 166,Referenz auf die Gerätenummer,SG8,RFF,1154,00111,,,Gerätenummer,X, + 167,Referenz auf die ID einer Messlokation,SG8,RFF,,00112,,,,Muss, + 168,Referenz auf die ID einer Messlokation,SG8,RFF,1153,00112,Z19,,Messlokation,X, + 169,Referenz auf die ID einer Messlokation,SG8,RFF,1154,00112,,,ID einer Messlokation,X [951],[951] Format: Zählpunktbezeichnung + 170,OBIS-Kennzahl der Zähleinrichtung / Mengenumwerter,SG8,PIA,,00113,,,,Muss, + 171,OBIS-Kennzahl der Zähleinrichtung / Mengenumwerter,SG8,PIA,4347,00113,5,,Produktidentifikation,X, + 172,OBIS-Kennzahl der Zähleinrichtung / Mengenumwerter,SG8,PIA,7140,00113,,,OBIS-Kennzahl derZähleinrichtung,X [324],"[324] Es sind alle OBIS- Kennzahlen gem. EDI@Energy Codeliste der OBIS Kennzahlen Kap. 4. anzugeben welche an der Zähleinrichtung genutzt werden. Der Mindestumfang der OBIS-Kennzahlen ergibt sich aus den genannten Messprodukt-Codes dem Kap. 5.2 des Dokumentes ""Codeliste der Konfigurationen""" + 173,OBIS-Kennzahl der Zähleinrichtung / Mengenumwerter,SG8,PIA,7143,00113,SRW,,OBIS-Kennzahl,X, + 174,Wertegranularität,SG10,,,,,,,Muss [274],[274] Wenn in derselben SG8 SEQ+Z20 (OBIS- Daten der Zähleinrichtung / Mengenumwerter) das PIA+5+7-b?:3.0.0 / 7- b?:6.0.0 / 7-b?:3.1.0 / 7-b?:6.1.0 / 7-b?:3.2.0 / 7-b?:6.2.0 / 7-b?:13.2.0 / 7-b?:16.2.0 / 7-b?:1.0.0 / 7-b?:2.0.0 / 7-b?:4.0.0 / 7-b?:5.0.0 / 7-b?:11.2.0 / 7-b?:12.2.0 / 7-b?:14.2.0 / 7-b?:15.2.0 vorhanden + 175,Wertegranularität,SG10,CCI,,00114,,,,Muss, + 176,Wertegranularität,SG10,CCI,7037,00114,ZE4,,Wertegranularität,X, + 177,Wertegranularität,SG10,CAV,,00115,,,,Muss, + 178,Wertegranularität,SG10,CAV,7111,00115,ZD9,,Jährlich,X, + 179,Wertegranularität,SG10,CAV,7111,,ZE8,,Halbjährlich,X, + 180,Wertegranularität,SG10,CAV,7111,,ZE9,,Quartalsweise,X, + 181,Wertegranularität,SG10,CAV,7111,,ZB7,,Monatlich,X, + 182,Vor- und Nachkommastellen des Zählwerks,SG10,,,,,,,Muss [274],[274] Wenn in derselben + 183,Vor- und Nachkommastellen des Zählwerks,SG10,CCI,,00116,,,,Muss, + 184,Vor- und Nachkommastellen des Zählwerks,SG10,CCI,7059,00116,11,,Produkt,X, + 185,Vor- und Nachkommastellen des Zählwerks,SG10,CCI,7037,00116,Z33,,Vor- undNachkommastellen desZählwerkes,X, + 186,Vor- und Nachkommastellen des Zählwerks,SG10,CAV,,00117,,,,Muss, + 187,Vor- und Nachkommastellen des Zählwerks,SG10,CAV,7110,00117,,,Angabe der Vorkommastelle,X, + 188,Vor- und Nachkommastellen des Zählwerks,SG10,CAV,7110,00117,,,Angabe der Nachkommastelle,X, + 189,Bezeichnung des Zählwerks auf dem Gerät,SG10,,,,,,,Muss [123]∧ [274],"[123] Wenn noch mindestens eine weitere SG8 SEQ+Z20 (OBIS- Daten der Zähleinrichtung / Mengenumwerter) mit dem SG8 RFF+MG / Z11 (Gerätenummer des Zählers / Mengenumwerters) auf die gleiche Identifikation/Nummer des Gerätes referenziert + [274] Wenn in derselben SG8 SEQ+Z20 (OBIS- Daten der Zähleinrichtung / Mengenumwerter) das" + 190,Bezeichnung des Zählwerks auf dem Gerät,SG10,CCI,,00118,,,,Muss, + 191,Bezeichnung des Zählwerks auf dem Gerät,SG10,CCI,7037,00118,Z63,,Lokale Kennzeichnung zuKontrollzwecken,X, + 192,Bezeichnung des Zählwerks auf dem Gerät,SG10,CCI,7036,00118,,,Bezeichnung des Zählwerks aufdem Gerät,X, + 193,Kommunikationseinrichtun gsdaten,SG8,,,,,,,Kann [345],"[133] Wenn an der übermittelten Marktlokation / Messlokation vorhanden + [336] Wenn in Änderungsmeldung gefüllt + [345] Wenn 33-stelliger Meldepunkt im SG5 LOC+172 (Meldepunkt) vorhanden + [530] Hinweis: Es sind alle an dem Meldepunkt vorhandenen Daten, die mit dieser Segmentgruppe übermittelt werden und zum Datum „Änderung zum“ Gültigkeit haben, anzugeben. Dies kann zur Folge haben, dass Segmentgruppen bzw. Segmente zu wiederholen sind + [2119] Je SG8 SEQ+Z13 (Smartmeter-Gateway) ist genau einmal die" + 194,Kommunikationseinrichtun gsdaten,SG8,SEQ,,00119,,,,Muss, + 195,Kommunikationseinrichtun gsdaten,SG8,SEQ,1229,00119,Z05,,Kommunikationseinrichtungsdaten,X, + 196,Referenz auf die Gerätenummer,SG8,RFF,,00120,,,,Muss, + 197,Referenz auf die Gerätenummer,SG8,RFF,1153,00120,MG,,Gerätenummer desZählers,X, + 198,Referenz auf die Gerätenummer,SG8,RFF,1154,00120,,,Gerätenummer,X, + 199,Kommunikationseinrichtun g,SG10,,,,,,,Muss, + 200,Kommunikationseinrichtun g,SG10,CCI,,00121,,,,Muss, + 201,Kommunikationseinrichtun g,SG10,CCI,7037,00121,Z26,,Kommunikationseinrichtung,X, + 202,Identifikation / Nummer des Gerätes,SG10,CAV,,00122,,,,Muss, + 203,Identifikation / Nummer des Gerätes,SG10,CAV,7111,00122,Z30,,Gerätenummer,X, + 204,Identifikation / Nummer des Gerätes,SG10,CAV,7110,00122,,,Gerätenummer,X, + 205,Kommunikationseinrichtun gstyp,SG10,CAV,,00123,,,,Muss, + 206,Kommunikationseinrichtun gstyp,SG10,CAV,7111,00123,GSM,,GSM/GPRS/UMTS-Kom.-Einr.,X, + 207,Kommunikationseinrichtun gstyp,SG10,CAV,7111,,ETH,,Ethernet-Kom.-Einricht.LAN/WLAN,X, + 208,Kommunikationseinrichtun gstyp,SG10,CAV,7111,,PLC,,PLC-Kom.-Einrichtung,X, + 209,Kommunikationseinrichtun gstyp,SG10,CAV,7111,,PST,,Festnetz-Kom.-Einricht.TAE,X, + 210,Kommunikationseinrichtun gstyp,SG10,CAV,7111,,DSL,,DSL-Kom.Einr.,X, + 211,Kommunikationseinrichtun gstyp,SG10,CAV,7111,,LTE,,LTE-Kom.-Einr.,X, + 212,Smartmeter-Gateway,SG8,,,,,,,Kann,"[130] Wenn an Messlokation vorhanden + [336] Wenn in Änderungsmeldung gefüllt" + 213,Smartmeter-Gateway,SG8,SEQ,,00124,,,,Muss, + 214,Smartmeter-Gateway,SG8,SEQ,1229,00124,Z13,,Smartmeter-Gateway,X, + 215,Smartmeter-Gateway,SG10,,,,,,,Muss, + 216,Smartmeter-Gateway,SG10,CCI,,00125,,,,Muss, + 217,Smartmeter-Gateway,SG10,CCI,7037,00125,Z75,,Smartmeter-Gateway,X, + 218,Identifikation / Nummer des Gerätes,SG10,CAV,,00126,,,,Muss, + 219,Identifikation / Nummer des Gerätes,SG10,CAV,7111,00126,Z30,,Gerätenummer,X, + 220,Identifikation / Nummer des Gerätes,SG10,CAV,7110,00126,,,Gerätenummer,X [952],[952] Format: Gerätenummer nach DIN 43863-5 + 221,Nachrichten-Endesegment,,UNT,,00149,,,,Muss, + 222,Nachrichten-Endesegment,,UNT,0074,00149,,,Anzahl der Segmente in einerNachricht,X, + 223,Nachrichten-Endesegment,,UNT,0062,00149,,,Nachrichten-Referenznummer,X, + + ''' +# --- +# name: TestCli.test_kohlrahbi_cli_with_valid_arguments[44163] + ''' + ,Segmentname,Segmentgruppe,Segment,Datenelement,Segment ID,Code,Qualifier,Beschreibung,Bedingungsausdruck,Bedingung + 0,Nachrichten-Kopfsegment,,UNH,,00003,,,,Muss, + 1,Nachrichten-Kopfsegment,,UNH,0062,00003,,,Nachrichten-Referenznummer,X, + 2,Nachrichten-Kopfsegment,,UNH,0065,00003,UTILMD,,Netzanschluss-Stammdaten,X, + 3,Nachrichten-Kopfsegment,,UNH,0052,00003,D,,Entwurfs-Version,X, + 4,Nachrichten-Kopfsegment,,UNH,0054,00003,11A,,Ausgabe 2011 - A,X, + 5,Nachrichten-Kopfsegment,,UNH,0051,00003,UN,,UN/CEFACT,X, + 6,Nachrichten-Kopfsegment,,UNH,0057,00003,Versionsnummer derzugrundeliegenden BDEW-Nachrichtenbeschreibung,,G1.0a,X, + 7,Beginn der Nachricht,,BGM,,00004,,,,Muss, + 8,Beginn der Nachricht,,BGM,1001,00004,E03,,Änderungsmeldungen,X, + 9,Beginn der Nachricht,,BGM,1004,00004,,,Dokumentennummer,X, + 10,Nachrichtendatum,,DTM,,00005,,,,Muss, + 11,Nachrichtendatum,,DTM,2005,00005,137,,Dokumenten-/Nachrichtendatum/-zeit,X, + 12,Nachrichtendatum,,DTM,2380,00005,,,"Datum oder Uhrzeit oder Zeitspanne, Wert",X [931] [494],"[494] Das hier genannte Datum muss der Zeitpunkt sein, zu dem das Dokument erstellt wurde, oder ein Zeitpunkt, der davor liegt + [931] Format: ZZZ = +00" + 13,EDIFACT Struktur,,DTM,2379,00005,303,,CCYYMMDDHHMMZZZ,X, + 14,MP-ID Absender,SG2,,,,,,,Muss, + 15,MP-ID Absender,SG2,NAD,,00008,,,,Muss, + 16,MP-ID Absender,SG2,NAD,3035,00008,MS,,Dokumenten-/Nachrichtenaussteller bzw. -absender,X, + 17,MP-ID Absender,SG2,NAD,3039,00008,,,MP-ID,X, + 18,MP-ID Absender,SG2,NAD,3055,00008,9,,GS1,X, + 19,MP-ID Absender,SG2,NAD,3055,,332,,"DE, DVGW Service & ConsultGmbH",X, + 20,Ansprechpartner,SG3,,,,,,,Kann, + 21,Ansprechpartner,SG3,CTA,,00009,,,,Muss, + 22,Ansprechpartner,SG3,CTA,3139,00009,IC,,Informationskontakt,X, + 23,Ansprechpartner,SG3,CTA,3412,00009,,,Name vom Ansprechpartner,X, + 24,Kommunikationsverbindung,SG3,COM,,00010,,,,Muss, + 25,Kommunikationsverbindung,SG3,COM,3148,00010,,,Nummer / Adresse,X, + 26,Kommunikationsverbindung,SG3,COM,3155,00010,EM,,Elektronische Post,X [1P0..1], + 27,Kommunikationsverbindung,SG3,COM,3155,,FX,,Telefax,X [1P0..1], + 28,Kommunikationsverbindung,SG3,COM,3155,,TE,,Telefon,X [1P0..1], + 29,Kommunikationsverbindung,SG3,COM,3155,,AJ,,weiteres Telefon,X [1P0..1], + 30,Kommunikationsverbindung,SG3,COM,3155,,AL,,Handy,X [1P0..1], + 31,MP-ID Empfänger,SG2,,,,,,,Muss, + 32,MP-ID Empfänger,SG2,NAD,,00011,,,,Muss, + 33,MP-ID Empfänger,SG2,NAD,3035,00011,MR,,Nachrichtenempfänger,X, + 34,MP-ID Empfänger,SG2,NAD,3039,00011,,,MP-ID,X, + 35,MP-ID Empfänger,SG2,NAD,3055,00011,9,,GS1,X, + 36,MP-ID Empfänger,SG2,NAD,3055,,332,,"DE, DVGW Service & ConsultGmbH",X, + 37,Vorgang,SG4,,,,,,,Muss, + 38,Vorgang,SG4,IDE,,00012,,,,Muss, + 39,Vorgang,SG4,IDE,7495,00012,24,,Transaktion,X, + 40,Vorgang,SG4,IDE,7402,00012,,,Vorgangsnummer,X, + 41,Beginn zum,SG4,DTM,,00015,,,,Muss, + 42,Beginn zum,SG4,DTM,2005,00015,92,,Datum Vertragsbeginn,X, + 43,Beginn zum,SG4,DTM,2380,00015,,,"Datum oder Uhrzeit oder Zeitspanne, Wert",X [UB2] ∧[528],[528] Hinweis: Es ist das Datum/ Daten aus der Anfrage zu verwenden + 44,Beginn zum,SG4,DTM,2379,00015,303,,CCYYMMDDHHMMZZZ,X, + 45,"Änderung zum, Gültigkeit, Beginndatum",SG4,DTM,,00018,,,,Muss, + 46,EDIFACT Struktur,SG4,DTM,2005,00018,157,,"Gültigkeit, Beginndatum",X, + 47,EDIFACT Struktur,SG4,DTM,2380,00018,,,"Datum oder Uhrzeit oder Zeitspanne, Wert",X [UB2] ∧[528],[528] Hinweis: Es ist das Datum/ Daten aus der Anfrage zu verwenden + 48,EDIFACT Struktur,SG4,DTM,2379,00018,303,,CCYYMMDDHHMMZZZ,X, + 49,Transaktionsgrund,SG4,STS,,00026,,,,Muss [2061],[2061] Segment bzw. Segmentgruppe ist genau einmal je SG4 IDE (Vorgang) anzugeben + 50,Transaktionsgrund,SG4,STS,9015,00026,7,,Transaktionsgrund,X, + 51,Transaktionsgrund,SG4,STS,9013,00026,ZG8,,Anfrage an MSB ohneAbhängigkeiten,X, + 52,Status der Antwort,SG4,STS,,00028,,,,Muss [249],[249] Innerhalb eines SG4 IDE müssen alle DE1131 der SG4 STS+E01 den identischen Wert enthalten + 53,Status der Antwort,SG4,STS,9015,00028,E01,,Status der Antwort,X, + 54,Status der Antwort,SG4,STS,9013,00028,,,Code des Prüfschritts,X, + 55,Status der Antwort,SG4,STS,1131,00028,G_0043,,Codeliste Gas Nr. G_0043,, + 56,Status der Antwort,SG4,STS,1131,,G_0044,,Codeliste Gas Nr. G_0044,X, + 57,Status der Antwort,SG4,STS,1131,,G_0046,,Codeliste Gas Nr. G_0046,, + 58,Meldepunkt,SG5,,,,,,,Muss [2061],[2061] Segment bzw. Segmentgruppe ist genau einmal je SG4 IDE (Vorgang) anzugeben + 59,Meldepunkt,SG5,LOC,,00035,,,,Muss, + 60,Meldepunkt,SG5,LOC,3227,00035,172,,Meldepunkt,X, + 61,Meldepunkt,SG5,LOC,3225,00035,,,Identifikator,X [951],[951] Format: Zählpunktbezeichnung + 62,Prüfidentifikator,SG6,,,,,,,Muss, + 63,Prüfidentifikator,SG6,RFF,,00037,,,,Muss, + 64,Prüfidentifikator,SG6,RFF,1153,00037,Z13,,Prüfidentifikator,X, + 65,Prüfidentifikator,SG6,RFF,1154,00037,44162,,SDÄ /Anfrage an MSB ohneAbhängigkeiten von LF / MSB anNB,, + 66,Prüfidentifikator,SG6,RFF,1154,,44163,,SDÄ Gas / Antwort auf Anfrage anMSB ohne Abhängigkeiten LF /MSB an NB,X, + 67,Prüfidentifikator,SG6,RFF,1154,,44164,,SDÄ Gas / Ablehnung auf Anfragean MSB ohne Abhängigkeiten LF /MSB an NB,, + 68,Prüfidentifikator,SG6,RFF,1154,,44165,,SDÄ Gas /Anfrage an MSB ohneAbhängigkeiten NB [Verteiler] anMSB,, + 69,Prüfidentifikator,SG6,RFF,1154,,44166,,SDÄ Gas /Anfrage an MSB ohneAbhängigkeiten NB [Berechtigter],, + 70,EDIFACT Struktur,SG6,RFF,1154,,44167,,SDÄ Gas / Antwort auf Anfrage anMSB ohne Abhängigkeiten MSB anNB,, + 71,Referenz Vorgangsnummer (aus Anfragenachricht),SG6,,,,,,,Muss, + 72,Referenz Vorgangsnummer (aus Anfragenachricht),SG6,RFF,,00038,,,,Muss, + 73,Referenz Vorgangsnummer (aus Anfragenachricht),SG6,RFF,1153,00038,TN,,Transaktions-Referenznummer,X, + 74,Referenz Vorgangsnummer (aus Anfragenachricht),SG6,RFF,1154,00038,,,Vorgangsnummer,X, + 75,Kunde des Messstellenbetreibers,SG12,,,,,,,,"[202] Wenn SG4 STS+E01+ZG2 (Status der Antwort: Gültiges Ergebnis nach der Datenprüfung) vorhanden + [336] Wenn in Änderungsmeldung gefüllt" + 76,Kunde des Messstellenbetreibers,SG12,NAD,,00138,,,,, + 77,Kunde des Messstellenbetreibers,SG12,NAD,3035,00138,Z07,,Kunde des MSB,, + 78,Kunde des Messstellenbetreibers,SG12,NAD,3036,00138,,,Name,, + 79,Kunde des Messstellenbetreibers,SG12,NAD,3045,00138,Z01,,Struktur von Personennamen,, + 80,Kunde des Messstellenbetreibers,SG12,NAD,3045,,Z02,,Struktur der Firmenbezeichnung,, + 81,Kunden des Messstellenbetreibers,SG12,,,,,,,,"[202] Wenn SG4 STS+E01+ZG2 (Status der Antwort: Gültiges Ergebnis nach der Datenprüfung) vorhanden + [336] Wenn in Änderungsmeldung gefüllt" + 82,Kunden des Messstellenbetreibers,SG12,NAD,,00139,,,,, + 83,Kunden des Messstellenbetreibers,SG12,NAD,3035,00139,Z08,,Korrespondenzanschrift desKunden des MSB,, + 84,Kunden des Messstellenbetreibers,SG12,NAD,3036,00139,,,Name,, + 85,Kunden des Messstellenbetreibers,SG12,NAD,3045,00139,Z01,,Struktur von Personennamen,, + 86,Kunden des Messstellenbetreibers,SG12,NAD,3045,,Z02,,Struktur der Firmenbezeichnung,, + 87,Kunden des Messstellenbetreibers,SG12,NAD,3042,00139,,,Straße und Hausnummer oder Postfach,, + 88,Kunden des Messstellenbetreibers,SG12,NAD,3164,00139,,,Ort,, + 89,Kunden des Messstellenbetreibers,SG12,NAD,3251,00139,,,Postleitzahl,,"[166] Wenn vorhanden + [268] Wenn der Code im DE3207 in der ""EDI@Energy Codeliste der europäischen Ländercodes"" in der Spalte ""PLZ vorhanden"" ein ""X"" aufgeführt ist" + 90,Kunden des Messstellenbetreibers,SG12,NAD,3207,00139,,,"Ländername, Code",, + 91,Messlokationsadresse,SG12,,,,,,,,"[202] Wenn SG4 STS+E01+ZG2 (Status der Antwort: Gültiges Ergebnis nach der Datenprüfung) vorhanden + [336] Wenn in Änderungsmeldung gefüllt" + 92,Messlokationsadresse,SG12,NAD,,00146,,,,, + 93,Messlokationsadresse,SG12,NAD,3035,00146,Z03,,Messlokationsadresse,, + 94,Messlokationsadresse,SG12,NAD,3124,00146,,,Zusatzinformation zur Identifizierung,, + 95,Messlokationsadresse,SG12,NAD,3042,00146,,,Straße und Hausnummer oder Postfach,,"[166] Wenn vorhanden + [212] Wenn im selben SG12 NAD DE3124 nicht vorhanden" + 96,Messlokationsadresse,SG12,NAD,3164,00146,,,Ort,, + 97,Messlokationsadresse,SG12,NAD,3251,00146,,,Postleitzahl,, + 98,Messlokationsadresse,SG12,NAD,3207,00146,,,"Ländername, Code",, + 99,Name und Adresse für die Ablesekarte,SG12,,,,,,,Muss [345],[202] Wenn SG4 STS+E01+ZG2 (Status der Antwort: Gültiges Ergebnis nach der Datenprüfung) vorhanden + 100,EDIFACT Struktur,SG12,NAD,,00147,,,,Muss, + 101,EDIFACT Struktur,SG12,NAD,3035,00147,Z05,,Name und Adresse für dieAblesekarte,X, + 102,EDIFACT Struktur,SG12,NAD,3036,00147,,,Name,X, + 103,EDIFACT Struktur,SG12,NAD,3045,00147,Z01,,Struktur von Personennamen,X, + 104,EDIFACT Struktur,SG12,NAD,3045,,Z02,,Struktur der Firmenbezeichnung,X, + 105,EDIFACT Struktur,SG12,NAD,3042,00147,,,Straße und Hausnummer oder Postfach,X, + 106,EDIFACT Struktur,SG12,NAD,3164,00147,,,Ort,X, + 107,EDIFACT Struktur,SG12,NAD,3251,00147,,,Postleitzahl,M [268]S [166],"[166] Wenn vorhanden + [268] Wenn der Code im DE3207 in der ""EDI@Energy Codeliste der europäischen Ländercodes"" in der Spalte ""PLZ vorhanden"" ein ""X"" aufgeführt ist" + 108,EDIFACT Struktur,SG12,NAD,3207,00147,,,"Ländername, Code",X, + 109,Referenz auf die ID einer Messlokation,SG12,RFF,,00148,,,,Muss, + 110,EDIFACT Struktur,SG12,RFF,1153,00148,Z19,,Messlokation,X, + 111,EDIFACT Struktur,SG12,RFF,1154,00148,,,ID einer Messlokation,X [951],[951] Format: Zählpunktbezeichnung + 112,Nachrichten-Endesegment,,UNT,,00149,,,,Muss, + 113,Nachrichten-Endesegment,,UNT,0074,00149,,,Anzahl der Segmente in einer Nachricht,X, + 114,Nachrichten-Endesegment,,UNT,0062,00149,,,Nachrichten-Referenznummer,X, + + ''' +# --- +# name: TestCli.test_kohlrahbi_cli_with_valid_arguments[44180] + ''' + ,Segmentname,Segmentgruppe,Segment,Datenelement,Segment ID,Code,Qualifier,Beschreibung,Bedingungsausdruck,Bedingung + 0,Nachrichten-Kopfsegment,,UNH,,00003,,,,Muss, + 1,Nachrichten-Kopfsegment,,UNH,0062,00003,,,Nachrichten-Referenznummer,X, + 2,Nachrichten-Kopfsegment,,UNH,0065,00003,UTILMD,,Netzanschluss-Stammdaten,X, + 3,Nachrichten-Kopfsegment,,UNH,0052,00003,D,,Entwurfs-Version,X, + 4,Nachrichten-Kopfsegment,,UNH,0054,00003,11A,,Ausgabe 2011 - A,X, + 5,Nachrichten-Kopfsegment,,UNH,0051,00003,UN,,UN/CEFACT,X, + 6,Nachrichten-Kopfsegment,,UNH,0057,00003,Versionsnummer derzugrundeliegendenBDEW-Nachrichtenbeschreibung,,G1.0a,X, + 7,Beginn der Nachricht,,BGM,,00004,,,,Muss, + 8,Beginn der Nachricht,,BGM,1001,00004,E03,,Änderungsmeldungen,X, + 9,Beginn der Nachricht,,BGM,1004,00004,,,Dokumentennummer,X, + 10,Nachrichtendatum,,DTM,,00005,,,,Muss, + 11,Nachrichtendatum,,DTM,2005,00005,137,,Dokumenten-/Nachrichtendatum/-zeit,X, + 12,Nachrichtendatum,,DTM,2380,00005,,,"Datum oder Uhrzeit oderZeitspanne, Wert",X [931][494],"[494] Das hier genannte Datum muss der Zeitpunkt sein, zu dem das Dokument erstellt wurde, oder ein Zeitpunkt, der davor liegt + [931] Format: ZZZ = +00" + 13,Nachrichtendatum,,DTM,2379,00005,303,,CCYYMMDDHHMMZZZ,X, + 14,MP-ID Absender,SG2,,,,,,,Muss, + 15,MP-ID Absender,SG2,NAD,,00008,,,,Muss, + 16,MP-ID Absender,SG2,NAD,3035,00008,MS,,Dokumenten-/Nachrichtenausstellerbzw. -absender,X, + 17,MP-ID Absender,SG2,NAD,3039,00008,,,MP-ID,X, + 18,MP-ID Absender,SG2,NAD,3055,00008,9,,GS1,X, + 19,MP-ID Absender,SG2,NAD,3055,,332,,"DE, DVGW Service &Consult GmbH",X, + 20,Ansprechpartner,SG3,,,,,,,Kann, + 21,Ansprechpartner,SG3,CTA,,00009,,,,Muss, + 22,Ansprechpartner,SG3,CTA,3139,00009,IC,,Informationskontakt,X, + 23,Ansprechpartner,SG3,CTA,3412,00009,,,Name vom Ansprechpartner,X, + 24,Kommunikationsverbindung,SG3,COM,,00010,,,,Muss, + 25,Kommunikationsverbindung,SG3,COM,3148,00010,,,Nummer / Adresse,X, + 26,Kommunikationsverbindung,SG3,COM,3155,00010,EM,,Elektronische Post,X [1P0..1], + 27,Kommunikationsverbindung,SG3,COM,3155,,FX,,Telefax,X [1P0..1], + 28,Kommunikationsverbindung,SG3,COM,3155,,TE,,Telefon,X [1P0..1], + 29,Kommunikationsverbindung,SG3,COM,3155,,AJ,,weiteres Telefon,X [1P0..1], + 30,Kommunikationsverbindung,SG3,COM,3155,,AL,,Handy,X [1P0..1], + 31,MP-ID Empfänger,SG2,,,,,,,Muss, + 32,MP-ID Empfänger,SG2,NAD,,00011,,,,Muss, + 33,MP-ID Empfänger,SG2,NAD,3035,00011,MR,,Nachrichtenempfänger,X, + 34,MP-ID Empfänger,SG2,NAD,3039,00011,,,MP-ID,X, + 35,MP-ID Empfänger,SG2,NAD,3055,00011,9,,GS1,X, + 36,MP-ID Empfänger,SG2,NAD,3055,,332,,"DE, DVGW Service &Consult GmbH",X, + 37,Vorgang,SG4,,,,,,,Muss, + 38,Vorgang,SG4,IDE,,00012,,,,Muss, + 39,Vorgang,SG4,IDE,7495,00012,24,,Transaktion,X, + 40,Vorgang,SG4,IDE,7402,00012,,,Vorgangsnummer,X, + 41,Beginn zum,SG4,DTM,,00015,,,,Muss, + 42,Beginn zum,SG4,DTM,2005,00015,92,,Datum Vertragsbeginn,X, + 43,Beginn zum,SG4,DTM,2380,00015,,,"Datum oder Uhrzeit oderZeitspanne, Wert",X [UB2],[528] Hinweis: Es ist das Datum/ Daten aus der Anfrage zu verwenden + 44,Beginn zum,SG4,DTM,2379,00015,303,,CCYYMMDDHHMMZZZ,X, + 45,"Änderung zum, Gültigkeit, Beginndatum",SG4,DTM,,00018,,,,Muss, + 46,"Änderung zum, Gültigkeit, Beginndatum",SG4,DTM,2005,00018,157,,"Gültigkeit, Beginndatum",X, + 47,"Änderung zum, Gültigkeit, Beginndatum",SG4,DTM,2380,00018,,,"Datum oder Uhrzeit oderZeitspanne, Wert",X [UB2],[528] Hinweis: Es ist das Datum/ Daten aus der Anfrage zu verwenden + 48,"Änderung zum, Gültigkeit, Beginndatum",SG4,DTM,2379,00018,303,,CCYYMMDDHHMMZZZ,X, + 49,Transaktionsgrund,SG4,STS,,00026,,,,Muss [2061],[2061] Segment bzw. Segmentgruppe ist genau einmal je SG4 IDE (Vorgang) anzugeben + 50,Transaktionsgrund,SG4,STS,9015,00026,7,,Transaktionsgrund,X, + 51,Transaktionsgrund,SG4,STS,9013,00026,ZJ1,,Anfrage der komplexenMarktlokationsstruktur,X, + 52,Status der Antwort,SG4,STS,,00028,,,,,[249] Innerhalb eines SG4 IDE müssen alle DE1131 der SG4 STS+E01 den identischen Wert enthalten + 53,Status der Antwort,SG4,STS,9015,00028,E01,,Status der Antwort,, + 54,Status der Antwort,SG4,STS,9013,00028,,,Code des Prüfschritts,, + 55,Status der Antwort,SG4,STS,1131,00028,G_0035,,Codeliste Gas Nr.G_0035,, + 56,Status der Antwort,SG4,STS,1131,,G_0036,,Codeliste Gas Nr.G_0036,, + 57,Meldepunkt,SG5,,,,,,,Muss [590],"[590] Hinweis: Es ist die ID der Marktlokation, welche dem LF zugeordnet sind, sowie alle Identifikatoren der Messlokationen anzugeben" + 58,Meldepunkt,SG5,LOC,,00035,,,,Muss, + 59,Meldepunkt,SG5,LOC,3227,00035,172,,Meldepunkt,X, + 60,Meldepunkt,SG5,LOC,3225,00035,,,Identifikator,X [953],[953] Format: Marktlokations-ID oder Zählpunktbezeichnung + 61,Prüfidentifikator,SG6,,,,,,,Muss, + 62,Prüfidentifikator,SG6,RFF,,00037,,,,Muss, + 63,Prüfidentifikator,SG6,RFF,1153,00037,Z13,,Prüfidentifikator,X, + 64,Prüfidentifikator,SG6,RFF,1154,00037,44180,,SDÄ Gas / Anfrage derkomplexenMarktlokationsstrukturLF an NB,X, + 65,Prüfidentifikator,SG6,RFF,1154,,44181,,SDÄ Gas / Antwort aufAnfrage der komplexenMarktlokationsstrukturNB an LF,, + 66,Prüfidentifikator,SG6,RFF,1154,,44182,,SDÄ Gas / Ablehnung derAnfrage der komplexenMarktlokationsstrukturNB an LF,, + 67,Referenz Vorgangsnummer (aus Anfragenachricht),SG6,,,,,,,, + 68,Referenz Vorgangsnummer (aus Anfragenachricht),SG6,RFF,,00038,,,,, + 69,Referenz Vorgangsnummer (aus Anfragenachricht),SG6,RFF,1153,00038,TN,,Transaktions-Referenznummer,, + 70,Referenz Vorgangsnummer (aus Anfragenachricht),SG6,RFF,1154,00038,,,Vorgangsnummer,, + 71,Nachrichten-Endesegment,,UNT,,00149,,,,Muss, + 72,Nachrichten-Endesegment,,UNT,0074,00149,,,Anzahl der Segmente in einerNachricht,X, + 73,Nachrichten-Endesegment,,UNT,0062,00149,,,Nachrichten-Referenznummer,X, + + ''' +# --- +# name: TestCli.test_kohlrahbi_cli_with_valid_arguments[55003] + ''' + ,Segmentname,Segmentgruppe,Segment,Datenelement,Segment ID,Code,Qualifier,Beschreibung,Bedingungsausdruck,Bedingung + 0,Nachrichten-Kopfsegment,,UNH,,00003,,,,Muss, + 1,Nachrichten-Kopfsegment,,UNH,0062,00003,,,Nachrichten-Referenznummer,X, + 2,Nachrichten-Kopfsegment,,UNH,0065,00003,UTILMD,,Netzanschluss-Stammdaten,X, + 3,Nachrichten-Kopfsegment,,UNH,0052,00003,D,,Entwurfs-Version,X, + 4,Nachrichten-Kopfsegment,,UNH,0054,00003,11A,,Ausgabe 2011 - A,X, + 5,Nachrichten-Kopfsegment,,UNH,0051,00003,UN,,UN/CEFACT,X, + 6,Nachrichten-Kopfsegment,,UNH,0057,00003,Versionsnummer derzugrundeliegendenBDEW-Nachrichtenbeschreibung,,S1.1a,X, + 7,Beginn der Nachricht,,BGM,,00004,,,,Muss, + 8,Beginn der Nachricht,,BGM,1001,00004,E01,,Anmeldungen,X, + 9,Beginn der Nachricht,,BGM,1004,00004,,,Dokumentennummer,X, + 10,Nachrichtendatum,,DTM,,00005,,,,Muss, + 11,Nachrichtendatum,,DTM,2005,00005,137,,Dokumenten-/Nachrichtendatum/-zeit,X, + 12,Nachrichtendatum,,DTM,2380,00005,,,"Datum oder Uhrzeit oderZeitspanne, Wert",X [931][494],"[494] Das hier genannte Datum muss der Zeitpunkt sein, zu dem das Dokument erstellt wurde, oder ein Zeitpunkt, der davor liegt + [931] Format: ZZZ = +00" + 13,Nachrichtendatum,,DTM,2379,00005,303,,CCYYMMDDHHMMZZZ,X, + 14,MP-ID Absender,SG2,,,,,,,Muss, + 15,MP-ID Absender,SG2,NAD,,00008,,,,Muss, + 16,MP-ID Absender,SG2,NAD,3035,00008,MS,,Dokumenten-/Nachrichtenausstellerbzw. -absender,X, + 17,MP-ID Absender,SG2,NAD,3039,00008,,,MP-ID,X, + 18,MP-ID Absender,SG2,NAD,3055,00008,9,,GS1,X, + 19,MP-ID Absender,SG2,NAD,3055,,293,,"DE, BDEW(Bundesverband derEnergie- undWasserwirtschaft e.V.)",X, + 20,Ansprechpartner,SG3,,,,,,,Kann, + 21,Ansprechpartner,SG3,CTA,,00009,,,,Muss, + 22,Ansprechpartner,SG3,CTA,3139,00009,IC,,Informationskontakt,X, + 23,Ansprechpartner,SG3,CTA,3412,00009,,,Name vom Ansprechpartner,X, + 24,Kommunikationsverbindung,SG3,COM,,00010,,,,Muss, + 25,Kommunikationsverbindung,SG3,COM,3148,00010,,,Nummer / Adresse,X (([939],[321] Wenn im DE3155 + 26,Kommunikationsverbindung,SG3,COM,3155,00010,EM,,Elektronische Post,X [1P0..1], + 27,Kommunikationsverbindung,SG3,COM,3155,,FX,,Telefax,X [1P0..1], + 28,Kommunikationsverbindung,SG3,COM,3155,,TE,,Telefon,X [1P0..1], + 29,Kommunikationsverbindung,SG3,COM,3155,,AJ,,weiteres Telefon,X [1P0..1], + 30,Kommunikationsverbindung,SG3,COM,3155,,AL,,Handy,X [1P0..1], + 31,MP-ID Empfänger,SG2,,,,,,,Muss, + 32,MP-ID Empfänger,SG2,NAD,,00011,,,,Muss, + 33,MP-ID Empfänger,SG2,NAD,3035,00011,MR,,Nachrichtenempfänger,X, + 34,MP-ID Empfänger,SG2,NAD,3039,00011,,,MP-ID,X, + 35,MP-ID Empfänger,SG2,NAD,3055,00011,9,,GS1,X, + 36,MP-ID Empfänger,SG2,NAD,3055,,293,,"DE, BDEW(Bundesverband derEnergie- undWasserwirtschaft e.V.)",X, + 37,Vorgang,SG4,,,,,,,Muss, + 38,Vorgang,SG4,IDE,,00020,,,,Muss, + 39,Vorgang,SG4,IDE,7495,00020,24,,Transaktion,X, + 40,Vorgang,SG4,IDE,7402,00020,,,Vorgangsnummer,X, + 41,Identifikationslogik,SG4,IMD,,00021,,,,, + 42,Identifikationslogik,SG4,IMD,7081,00021,Z36,,Identifikationslogik,, + 43,Identifikationslogik,SG4,IMD,7009,00021,Z12,,Marktlokations-ID,, + 44,Identifikationslogik,SG4,IMD,7009,,Z13,,Alle Identifikationsdaten,, + 45,Beginn zum,SG4,DTM,,00024,,,,, + 46,Beginn zum,SG4,DTM,2005,00024,92,,Datum Vertragsbeginn,, + 47,Beginn zum,SG4,DTM,2380,00024,,,"Datum oder Uhrzeit oderZeitspanne, Wert",, + 48,Beginn zum,SG4,DTM,2379,00024,303,,CCYYMMDDHHMMZZZ,, + 49,Ende zum,SG4,DTM,,00025,,,,,[10] Wenn SG4 STS+Z17 (Transaktionsgrund für befristete Anmeldung) vorhanden + 50,Ende zum,SG4,DTM,2005,00025,93,,Datum Vertragsende,, + 51,Ende zum,SG4,DTM,2380,00025,,,"Datum oder Uhrzeit oderZeitspanne, Wert",, + 52,Ende zum,SG4,DTM,2379,00025,303,,CCYYMMDDHHMMZZZ,, + 53,Bilanzierungsbeginn,SG4,DTM,,00029,,,,,"[18] Wenn SG4 DTM+93 (Ende zum) nicht vorhanden + [28] Wenn SG4 DTM+93 (Ende zum) vorhanden + [29] Wenn eine Bilanzierung stattfindet" + 54,Bilanzierungsbeginn,SG4,DTM,2005,00029,158,,Bilanzierungsbeginn,, + 55,Bilanzierungsbeginn,SG4,DTM,2380,00029,,,"Datum oder Uhrzeit oderZeitspanne, Wert",, + 56,Bilanzierungsbeginn,SG4,DTM,2379,00029,303,,CCYYMMDDHHMMZZZ,, + 57,Bilanzierungsende,SG4,DTM,,00030,,,,,"[28] Wenn SG4 DTM+93 (Ende zum) vorhanden + [64] Wenn SG4 DTM+158 (Bilanzierungsbeginn) vorhanden" + 58,Bilanzierungsende,SG4,DTM,2005,00030,159,,Bilanzierungsende,, + 59,Bilanzierungsende,SG4,DTM,2380,00030,,,"Datum oder Uhrzeit oderZeitspanne, Wert",, + 60,Bilanzierungsende,SG4,DTM,2379,00030,303,,CCYYMMDDHHMMZZZ,, + 61,Lieferbeginndatum in Bearbeitung,SG4,DTM,,00033,,,,Muss [355],[355] Wenn SG4 STS+E01++A11 vorhanden + 62,Lieferbeginndatum in Bearbeitung,SG4,DTM,2005,00033,Z07,,Lieferbeginndatum inBearbeitung,X, + 63,Lieferbeginndatum in Bearbeitung,SG4,DTM,2380,00033,,,"Datum oder Uhrzeit oderZeitspanne, Wert",X [UB1], + 64,Lieferbeginndatum in Bearbeitung,SG4,DTM,2379,00033,303,,CCYYMMDDHHMMZZZ,X, + 65,Datum für nächste Bearbeitung,SG4,DTM,,00034,,,,Muss [355],[355] Wenn SG4 STS+E01++A11 vorhanden + 66,Datum für nächste Bearbeitung,SG4,DTM,2005,00034,Z08,,Datum für nächsteBearbeitung,X, + 67,Datum für nächste Bearbeitung,SG4,DTM,2380,00034,,,"Datum oder Uhrzeit oderZeitspanne, Wert",X [UB1], + 68,Datum für nächste Bearbeitung,SG4,DTM,2379,00034,303,,CCYYMMDDHHMMZZZ,X, + 69,Transaktionsgrund,SG4,STS,,00037,,,,Muss [2061],[2061] Segment bzw. Segmentgruppe ist genau einmal je SG4 IDE (Vorgang) anzugeben + 70,Transaktionsgrund,SG4,STS,9015,00037,7,,Transaktionsgrund,X, + 71,Transaktionsgrund,SG4,STS,9013,00037,E01,,Ein-/Auszug (Umzug),X, + 72,Transaktionsgrund,SG4,STS,9013,,E02,,Einzug in Neuanlage,X, + 73,Transaktionsgrund,SG4,STS,9013,,E03,,Wechsel,X, + 74,Transaktionsgrund,SG4,STS,9013,,ZD2,,Lieferbeginn und,X, + 75,Transaktionsgrundergänzun g für Lieferende bei befristeter Anmeldung,SG4,STS,,00038,,,,Soll [37],[37] Wenn Anmeldung/ Änderung befristet + 76,Transaktionsgrundergänzun g für Lieferende bei befristeter Anmeldung,SG4,STS,9015,00038,Z17,,Transaktionsgrundergänzung für befristeteAnmeldung,X, + 77,Transaktionsgrundergänzun g für Lieferende bei befristeter Anmeldung,SG4,STS,9013,00038,E01,,Ein-/Auszug (Umzug),X, + 78,Transaktionsgrundergänzun g für Lieferende bei befristeter Anmeldung,SG4,STS,9013,,E03,,Wechsel,X, + 79,Status der Antwort,SG4,STS,,00039,,,,Muss [249],[249] Innerhalb eines SG4 IDE müssen alle DE1131 der SG4 STS+E01 den identischen Wert enthalten + 80,Status der Antwort,SG4,STS,9015,00039,E01,,Status der Antwort,X, + 81,Status der Antwort,SG4,STS,9013,00039,,,Code des Prüfschritts,X [359],"[359] Es sind nur Antwortcodes aus dem Cluster Ablehnung erlaubt + [360] Es sind nur Antwortcodes aus dem Cluster Zustimmung erlaubt" + 82,Status der Antwort,SG4,STS,1131,00039,E_0404,,EBD Nr. E_0404,X, + 83,Status der Antwort,SG4,STS,1131,,E_0462,,EBD Nr. E_0462,X, + 84,Status der Antwort des dritten Marktbeteiligten,SG4,STS,,00040,,,,Muss [356],[356] Wenn SG4 STS+E01++A50 vorhanden + 85,Status der Antwort des dritten Marktbeteiligten,SG4,STS,9015,00040,Z35,,Status der Antwort desdritten Marktbeteiligten,X, + 86,Status der Antwort des dritten Marktbeteiligten,SG4,STS,9013,00040,,,Code des Prüfschritts,X [366],[366] Bis auf den Code A30 sind alle Codes aus EBD E_0403 im Cluster Ablehnung erlaubt   + 87,Status der Antwort des dritten Marktbeteiligten,SG4,STS,1131,00040,E_0403,,EBD Nr. E_0403,X, + 88,Bemerkung (Feld für allgemeine Hinweise),SG4,FTX,,00043,,,,Kann, + 89,Bemerkung (Feld für allgemeine Hinweise),SG4,FTX,4451,00043,ACB,,ZusätzlicheInformationen (fürallgemeine Hinweise),X, + 90,Bemerkung (Feld für allgemeine Hinweise),SG4,FTX,4440,00043,,,Text für allgemeine Information,X, + 91,Netzlokation,SG5,,,,,,,,"[46] Wenn ID für Objekt vergeben wurde + [688] Hinweis: Es sind alle ID der Netzlokationen, welche der im LOC+Z16 angegebenen Marktlokation vorgelagert sind anzugeben" + 92,Netzlokation,SG5,LOC,,00050,,,,, + 93,Netzlokation,SG5,LOC,3227,00050,Z18,,Netzlokation,, + 94,Netzlokation,SG5,LOC,3225,00050,,,ID der Netzlokation,,[960] Format: Netzlokations-ID + 95,Marktlokation,SG5,,,,,,,Muss [2061]∧ [354],[165] Wenn bekannt + 96,Marktlokation,SG5,LOC,,00051,,,,Muss, + 97,Marktlokation,SG5,LOC,3227,00051,Z16,,Marktlokation,X, + 98,Marktlokation,SG5,LOC,3225,00051,,,ID der Marktlokation,X [950],[950] Format: Marktlokations-ID + 99,Technische Ressource,SG5,,,,,,,,"[46] Wenn ID für Objekt vergeben wurde + [689] Hinweis: Es sind alle ID der Technischen Ressourcen, welche der im LOC+Z16 angegebenen Marktlokation zugehören anzugeben + [694] Hinweis: Wenn in einer Marktlokation eine ID für eine Technischen Ressource vergeben wird, müssen für alle ggf. weitere Technische Ressourcen in der Marktlokation ID vergeben werden. Hintergrund: MSB und LF benötigen einen vollständigen Überblick auf die Art und Nutzung der Technischen Ressourcen in einer Marktlokation für die Plausibilisierung, Ersatzwertbildung, Produktauswahl bzw." + 100,Technische Ressource,SG5,LOC,,00052,,,,, + 101,Technische Ressource,SG5,LOC,3227,00052,Z20,,Technische Ressource,, + 102,Technische Ressource,SG5,LOC,3225,00052,,,ID der Technischen Ressource,,[922] Format: TR-ID + 103,Steuerbare Ressource,SG5,,,,,,,,"[46] Wenn ID für Objekt vergeben wurde + [690] Hinweis: Es sind alle ID der Steuerbaren Ressourcen, welche der im LOC+Z20 angegebenen Technischen Ressourcen zugeordnet sind anzugeben" + 104,Steuerbare Ressource,SG5,LOC,,00053,,,,, + 105,Steuerbare Ressource,SG5,LOC,3227,00053,Z19,,Steuerbare Ressource,, + 106,Steuerbare Ressource,SG5,LOC,3225,00053,,,ID der Steuerbaren Ressource,,[961] Format: SR-ID + 107,Messlokation,SG5,,,,,,,,"[165] Wenn bekannt + [166] Wenn vorhanden + [333] Wenn IMD+Z36+Z13 (Identifikationslogik: Alle Identifikationsdaten) vorhanden + [527] Hinweis: Es sind alle Identifikatoren der Messlokationen anzugeben + [669] Hinweis: Es können mehrere Messlokationen angegeben werden" + 108,Messlokation,SG5,LOC,,00055,,,,, + 109,Messlokation,SG5,LOC,3227,00055,Z17,,Messlokation,, + 110,Messlokation,SG5,LOC,3225,00055,,,ID der Messlokation,,[951] Format: Zählpunktbezeichnung + 111,Prüfidentifikator,SG6,,,,,,,Muss, + 112,Prüfidentifikator,SG6,RFF,,00057,,,,Muss, + 113,Prüfidentifikator,SG6,RFF,1153,00057,Z13,,Prüfidentifikator,X, + 114,Prüfidentifikator,SG6,RFF,1154,00057,55001,,GPKE / Anmeldung NN,, + 115,Prüfidentifikator,SG6,RFF,1154,,55002,,GPKE / BestätigungAnmeldung,, + 116,Prüfidentifikator,SG6,RFF,1154,,55003,,GPKE / AblehnungAnmeldung,X, + 117,Referenz Vorgangsnummer (aus Anfragenachricht),SG6,,,,,,,Muss, + 118,Referenz Vorgangsnummer (aus Anfragenachricht),SG6,RFF,,00058,,,,Muss, + 119,Referenz Vorgangsnummer (aus Anfragenachricht),SG6,RFF,1153,00058,TN,,Transaktions-Referenznummer,X, + 120,Referenz Vorgangsnummer (aus Anfragenachricht),SG6,RFF,1154,00058,,,Vorgangsnummer,X, + 121,Referenz auf die ID der Marktlokation für Termine der Marktlokation,SG6,,,,,,,, + 122,Referenz auf die ID der Marktlokation für Termine der Marktlokation,SG6,RFF,,00066,,,,,[636] Hinweis: Dieses RFF klassifiziert mit einem Code im DE1153 die in derselben Segmentgruppe enthaltenen DTM zu einem Markt- bzw. Messlokation relevanten Inhalt + 123,Referenz auf die ID der Marktlokation für Termine der Marktlokation,SG6,RFF,1153,00066,Z18,,Marktlokation,, + 124,Referenz auf die ID der Marktlokation für Termine der Marktlokation,SG6,RFF,1154,00066,,,ID der Marktlokation,,[950] Format: Marktlokations-ID + 125,Turnusablesung des MSB,SG6,DTM,,00067,,,,,"[21] Wenn SG10 CCI+++ZA6 (Prognose auf Basis von Profilen) in dieser SG8 vorhanden + [234] Wenn SG10 CCI+++Z83 (Messtechnische Einordnung der Marktlokation) CAV+Z53 (kME/ mME) vorhanden" + 126,Turnusablesung des MSB,SG6,DTM,2005,00067,752,,Turnusablesung,, + 127,Turnusablesung des MSB,SG6,DTM,2380,00067,,,"Datum oder Uhrzeit oderZeitspanne, Wert",, + 128,Turnusablesung des MSB,SG6,DTM,2379,00067,104,,MMWW-MMWW,, + 129,Turnusablesung des MSB,SG6,DTM,2379,,106,,MMDD,, + 130,Termin der Netznutzungsabrechnung,SG6,DTM,,00068,,,,, + 131,Termin der Netznutzungsabrechnung,SG6,DTM,2005,00068,Z21,,Termin derNetznutzungsabrechnung,, + 132,Termin der Netznutzungsabrechnung,SG6,DTM,2380,00068,,,"Datum oder Uhrzeit oderZeitspanne, Wert",, + 133,Termin der Netznutzungsabrechnung,SG6,DTM,2379,00068,106,,MMDD,, + 134,Termin der Netznutzungsabrechnung,SG6,DTM,2379,,104,,MMWW-MMWW,, + 135,Nächste Netznutzungsabrechnung,SG6,DTM,,00069,,,,,[230] Sich ergebendes Datum/ bzw. Endedatum des Turnuszeitraums aus DTM+Z21 (Termin der Netznutzungsabrechnun g) und DTM+Z09 (Nächste Netznutzungsabrechnun g) muss >= DTM+92 (Beginn zum) sein + 136,Nächste Netznutzungsabrechnung,SG6,DTM,2005,00069,Z09,,NächsteNetznutzungsabrechnung,, + 137,Nächste Netznutzungsabrechnung,SG6,DTM,2380,00069,,,"Datum oder Uhrzeit oderZeitspanne, Wert",, + 138,Nächste Netznutzungsabrechnung,SG6,DTM,2379,00069,602,,CCYY,, + 139,Netznutzungsabrechnungsi ntervall des NB,SG6,DTM,,00070,,,,, + 140,Netznutzungsabrechnungsi ntervall des NB,SG6,DTM,2005,00070,Z22,,Netznutzungsabrechnungs- bzw.Einspeisevergütungsintervall des NB,, + 141,Netznutzungsabrechnungsi ntervall des NB,SG6,DTM,2380,00070,,,"Datum oder Uhrzeit oderZeitspanne, Wert",, + 142,Netznutzungsabrechnungsi ntervall des NB,SG6,DTM,2379,00070,802,,Monat,, + 143,Referenz auf die Lokationsbündelstruktur,SG8,,,,,,,,"[309] Wenn DTM+137 (Nachrichtendatum) im DE2380 ≥ 202409302200?+00 + [513] Hinweis: Bei Anwendung dieser Segmentgruppe vor dem 01.10.2024 sind die Codes in diesem Segment noch nicht gültig. Somit wird der Geschäftsvorfall mit einer Verarbeitbarkeitsfehlerm eldung mit Fehlercode Z39 (Code nicht aus erlaubtem Wertebereich“) abgelehnt werden + [2061] Segment bzw. Segmentgruppe ist genau einmal je SG4 IDE (Vorgang) anzugeben" + 144,Referenz auf die Lokationsbündelstruktur,SG8,SEQ,,00071,,,,, + 145,Referenz auf die Lokationsbündelstruktur,SG8,SEQ,1229,00071,Z78,,Referenz auf dieLokationsbündelstruktur,, + 146,Referenz auf die Lokationsbündelstruktur,SG8,RFF,,00072,,,,, + 147,Referenz auf die Lokationsbündelstruktur,SG8,RFF,1153,00072,Z31,,Lokationsbündelstruktur,, + 148,Referenz auf die Lokationsbündelstruktur,SG8,RFF,1153,,Z39,,Keine standardisierteLokationsbündelstrukturvorhanden,, + 149,Referenz auf die Lokationsbündelstruktur,SG8,RFF,1154,00072,,,ID der Lokationsbündelstruktur,,"[335] Wenn im SG8 SEQ+Z78 RFF+Z31 ""Referenz auf die Lokationsbündelstruktur "" im DE1153 der Code Z31 ""Lokationsbündelstruktu r"" vorhanden ist" + 150,Referenz auf die Lokationsbündelstruktur,SG8,RFF,1156,00072,,,Fortlaufende Nummer einesLokationsbündels imGeschäftsvorfall,,"[32] Wenn mehr als ein SG8 SEQ+Z78 (Referenz auf die Lokationsbündelstruktur) vorhanden + [914] Format: Möglicher Wert: > 0 + [937] Format: keine Nachkommastelle" + 151,Zuordnung Lokation zum Objektcode des Lokationsbündels,SG8,,,,,,,,"[335] Wenn im SG8 SEQ+Z78 RFF+Z31 ""Referenz auf die Lokationsbündelstruktur "" im DE1153 der Code Z31 ""Lokationsbündelstruktu r"" vorhanden ist + [513] Hinweis: Bei Anwendung dieser Segmentgruppe vor dem 01.10.2024 sind die Codes in diesem Segment noch nicht gültig. Somit wird der Geschäftsvorfall mit einer Verarbeitbarkeitsfehlerm eldung mit Fehlercode Z39 (Code nicht aus erlaubtem Wertebereich“)" + 152,Zuordnung Lokation zum Objektcode des Lokationsbündels,SG8,SEQ,,00073,,,,, + 153,Zuordnung Lokation zum Objektcode des Lokationsbündels,SG8,SEQ,1229,00073,Z58,,Zuordnung Lokation zumObjektcode desLokationsbündels,, + 154,Referenz auf die ID der Netzlokation / Marktlokation / Messlokation / Technischen Ressource,SG8,RFF,,00074,,,,, + 155,Referenz auf die ID der Netzlokation / Marktlokation / Messlokation / Technischen Ressource,SG8,RFF,1153,00074,Z32,,Netzlokation,, + 156,Referenz auf die ID der Netzlokation / Marktlokation / Messlokation / Technischen Ressource,SG8,RFF,1153,,Z18,,Marktlokation,, + 157,Referenz auf die ID der Netzlokation / Marktlokation / Messlokation / Technischen Ressource,SG8,RFF,1153,,Z19,,Messlokation,, + 158,Referenz auf die ID der Netzlokation / Marktlokation / Messlokation / Technischen Ressource,SG8,RFF,1153,,Z37,,Technische Ressource,, + 159,Referenz auf die ID der Netzlokation / Marktlokation / Messlokation / Technischen Ressource,SG8,RFF,1154,00074,,,ID einer Lokation,,"[450] Wenn in demselben RFF der Code Z32 (Netzlokation) im DE1153 vorhanden + [451] Wenn in demselben RFF der Code Z18 (Marktlokation) im DE1153 vorhanden + [452] Wenn in demselben RFF der Code Z19 (Messlokation) im DE1153 vorhanden + [456] Wenn in demselben RFF der Code Z37 (Technische Ressource) im DE1153 vorhanden + [922] Format: TR-ID + [950] Format: Marktlokations-ID + [951] Format: Zählpunktbezeichnung + [960] Format: Netzlokations-ID" + 160,Referenz auf den Objektcode in der Lokationsbündelstruktur,SG8,RFF,,00075,,,,,[2313] Je SG8 SEQ+Z58 (Zuordnung Lokation zum Objektcode des Lokationsbündels) genau einmal anzugeben + 161,Referenz auf den Objektcode in der Lokationsbündelstruktur,SG8,RFF,1153,00075,Z33,,Objektcode der Lokationin derLokationsbündelstruktur,, + 162,Referenz auf den Objektcode in der Lokationsbündelstruktur,SG8,RFF,1154,00075,,,Objekt Code,, + 163,Referenz auf den Objektcode in der Lokationsbündelstruktur,SG8,RFF,1156,00075,,,Fortlaufende Nummer einesLokationsbündels imGeschäftsvorfall,,"[32] Wenn mehr als ein SG8 SEQ+Z78 (Referenz auf die Lokationsbündelstruktur) vorhanden + [914] Format: Möglicher Wert: > 0 + [937] Format: keine Nachkommastelle" + 164,Referenz auf die ID der vorgelagerten Netzlokation / Messlokation ,SG8,RFF,,00076,,,,,[290] Wenn der Objektcode im RFF+Z33 (Referenz auf den Objektcode in der Lokationsbündelstruktur) im DE1154 derselben SG8 SEQ+Z58 (Zuordnung Lokation zum Objektcode des Lokationsbündels) in einem weiteren SG8 SEQ+Z58 vorhanden ist + 165,Referenz auf die ID der vorgelagerten Netzlokation / Messlokation ,SG8,RFF,1153,00076,Z34,,vorgelagerteMesslokation,, + 166,Referenz auf die ID der vorgelagerten Netzlokation / Messlokation ,SG8,RFF,1153,,Z35,,vorgelagerteNetzlokation,, + 167,Referenz auf die ID der vorgelagerten Netzlokation / Messlokation ,SG8,RFF,1154,00076,,,ID einer Lokation,,"[471] Wenn in demselben RFF der Code Z35 (vorgelagerte Netzlokation) im DE1153 vorhanden + [472] Wenn in demselben RFF der Code Z34 (vorgelagerte Messlokation) im DE1153 vorhanden" + 168,Referenz auf die der Technischen Ressource zugeordneten Marktlokation ,SG8,RFF,,00077,,,,,"[290] Wenn der Objektcode im RFF+Z33 (Referenz auf den Objektcode in der Lokationsbündelstruktur) im DE1154 derselben SG8 SEQ+Z58 (Zuordnung Lokation zum Objektcode des Lokationsbündels) in einem weiteren SG8 SEQ+Z58 vorhanden ist + [291] Wenn in derselben SG8 SEQ+Z58 (Zuordnung Lokation zum Objektcode des Lokationsbündels) das RFF+Z37 vorhanden" + 169,Referenz auf die der Technischen Ressource zugeordneten Marktlokation ,SG8,RFF,1153,00077,Z16,,zugeordneteMarktlokation,, + 170,Referenz auf die der Technischen Ressource zugeordneten Marktlokation ,SG8,RFF,1154,00077,,,ID der Marktlokation,,[950] Format: Marktlokations-ID + 171,Daten der Netzlokation,SG8,,,,,,,,"[294] Wenn SG5 LOC+Z18 (Netzlokation) vorhanden + [2356] Je SG5 LOC+Z18 (Netzlokation) ist genau einmal die Segmentgruppe anzugeben" + 172,Daten der Netzlokation,SG8,SEQ,,00078,,,,, + 173,Daten der Netzlokation,SG8,SEQ,1229,00078,Z51,,Daten der Netzlokation,, + 174,Referenz auf die ID der Netzlokation,SG8,RFF,,00079,,,,, + 175,Referenz auf die ID der Netzlokation,SG8,RFF,1153,00079,Z32,,Netzlokation,, + 176,Referenz auf die ID der Netzlokation,SG8,RFF,1154,00079,,,ID der Netzlokation,,[960] Format: Netzlokations-ID + 177,Steuerkanal,SG10,,,,,,,, + 178,Steuerkanal,SG10,CCI,,00080,,,,, + 179,Steuerkanal,SG10,CCI,7059,00080,Z49,,Steuerkanal,, + 180,Steuerkanal,SG10,CCI,7037,00080,ZF2,,Kein Steuerkanalvorhanden,, + 181,Steuerkanal,SG10,CCI,7037,,ZF3,,Steuerkanal vorhanden,, + 182,Zugeordnete Marktpartner,SG10,,,,,,,, + 183,Zugeordnete Marktpartner,SG10,CCI,,00081,,,,, + 184,Zugeordnete Marktpartner,SG10,CCI,7037,00081,ZB3,,ZugeordneterMarktpartner,, + 185,Messstellenbetreiber,SG10,CAV,,00082,,,,, + 186,Messstellenbetreiber,SG10,CAV,7111,00082,Z91,,MSB,, + 187,Messstellenbetreiber,SG10,CAV,1131,00082,,,MP-ID,, + 188,Messstellenbetreiber,SG10,CAV,7110,00082,Z39,,GrundzuständigerMessstellenbetreiber,, + 189,Messstellenbetreiber,SG10,CAV,7110,,Z40,,WettbewerblicherMessstellenbetreiber,, + 190,Messstellenbetreiber,SG10,CAV,7110,,Z41,,Auffangmessstellenbetreiber,, + 191,OBIS-Daten der Netzlokation,SG8,,,,,,,,"[166] Wenn vorhanden + [294] Wenn SG5 LOC+Z18 (Netzlokation) vorhanden" + 192,OBIS-Daten der Netzlokation,SG8,SEQ,,00088,,,,, + 193,OBIS-Daten der Netzlokation,SG8,SEQ,1229,00088,Z57,,OBIS-Daten derNetzlokation,, + 194,Referenz auf die ID der Netzlokation,SG8,RFF,,00089,,,,, + 195,Referenz auf die ID der Netzlokation,SG8,RFF,1153,00089,Z32,,Netzlokation,, + 196,Referenz auf die ID der Netzlokation,SG8,RFF,1154,00089,,,ID der Netzlokation,,[960] Format: Netzlokations-ID + 197,OBIS-Kennzahl der Netzlokation,SG8,PIA,,00090,,,,, + 198,OBIS-Kennzahl der Netzlokation,SG8,PIA,4347,00090,5,,Produktidentifikation,, + 199,OBIS-Kennzahl der Netzlokation,SG8,PIA,7140,00090,,,OBIS-Kennzahl der Netzlokation,, + 200,OBIS-Kennzahl der Netzlokation,SG8,PIA,7143,00090,SRW,,OBIS-Kennzahl,, + 201,Produkt-Daten für Lieferant relevant,SG10,,,,,,,, + 202,Produkt-Daten für Lieferant relevant,SG10,CCI,,00093,,,,, + 203,Produkt-Daten für Lieferant relevant,SG10,CCI,7037,00093,ZA7,,LF,, + 204,Verwendungszweck der Werte,SG10,CAV,,00094,,,,, + 205,Verwendungszweck der Werte,SG10,CAV,7111,00094,Z47,,Endkundenabrechnung,, + 206,Verwendungszweck der Werte,SG10,CAV,7111,,ZD1,,Blindarbeitabrechnung /Betriebsführung,, + 207,Produkt-Daten der Netzlokation,SG8,,,,,,,,"[166] Wenn vorhanden + [294] Wenn SG5 LOC+Z18 (Netzlokation) vorhanden" + 208,Produkt-Daten der Netzlokation,SG8,SEQ,,00095,,,,, + 209,Produkt-Daten der Netzlokation,SG8,SEQ,1229,00095,Z60,,Produkt-Daten derNetzlokation,, + 210,Referenz auf die ID der Netzlokation,SG8,RFF,,00096,,,,, + 211,Referenz auf die ID der Netzlokation,SG8,RFF,1153,00096,Z32,,Netzlokation,, + 212,Referenz auf die ID der Netzlokation,SG8,RFF,1154,00096,,,ID einer Netzlokation,,[960] Format: Netzlokations-ID + 213,Produkt-Daten der Netzlokation,SG8,PIA,,00097,,,,, + 214,Produkt-Daten der Netzlokation,SG8,PIA,4347,00097,5,,Produktidentifikation,, + 215,Produkt-Daten der Netzlokation,SG8,PIA,7140,00097,,,Konfigurationsprodukt-Code,,"[412] Es sind ausschließlich Konfigurationsprodukt- Codes der ""EDI@Energy Codeliste der Konfigurationen"" aus Kapitel 4.2 Konfigurationsprodukte Leistungskurvendefinitio n erlaubt" + 216,Produkt-Daten der Netzlokation,SG8,PIA,7143,00097,Z12,,Konfigurationsprodukt,, + 217,Zugeordnete Leistungskurvendefinition,SG10,,,,,,,,[190] Wenn in derselben SG8 SEQ+Z60 (Produkt- Daten der Netzlokation) PIA+5+9991000000721: Z12 vorhanden + 218,Zugeordnete Leistungskurvendefinition,SG10,CCI,,00099,,,,, + 219,Zugeordnete Leistungskurvendefinition,SG10,CCI,7059,00099,Z53,,Code derLeistungskurvendefinitio,, + 220,Zugeordnete Leistungskurvendefinition,SG10,CCI,7037,00099,,,Code derLeistungskurvendefinition,, + 221,Auftraggebender Marktpartner,SG10,,,,,,,, + 222,Auftraggebender Marktpartner,SG10,CCI,,00100,,,,, + 223,Auftraggebender Marktpartner,SG10,CCI,7037,00100,ZB3,,ZugeordneterMarktpartner,, + 224,Auftraggebender Marktpartner,SG10,CAV,,00101,,,,, + 225,Auftraggebender Marktpartner,SG10,CAV,7111,00101,Z88,,NB,, + 226,Auftraggebender Marktpartner,SG10,CAV,7111,,Z89,,LF,, + 227,Auftraggebender Marktpartner,SG10,CAV,1131,00101,,,MP-ID,, + 228,Produkt-Daten für Marktrolle relevant,SG10,,,,,,,, + 229,Produkt-Daten für Marktrolle relevant,SG10,CCI,,00102,,,,, + 230,Produkt-Daten für Marktrolle relevant,SG10,CCI,7037,00102,ZA7,,LF,, + 231,Daten der Marktlokation,SG8,,,,,,,Muss [2061]∧ [25],"[25] Wenn SG5 LOC+Z16 (Marktlokation) vorhanden + [2061] Segment bzw. Segmentgruppe ist genau einmal je SG4 IDE (Vorgang) anzugeben" + 232,Daten der Marktlokation,SG8,SEQ,,00103,,,,Muss, + 233,Daten der Marktlokation,SG8,SEQ,1229,00103,Z01,,Daten der Marktlokation,X, + 234,Referenz auf die ID der Marktlokation,SG8,RFF,,00104,,,,, + 235,Referenz auf die ID der Marktlokation,SG8,RFF,1153,00104,Z18,,Marktlokation,, + 236,Referenz auf die ID der Marktlokation,SG8,RFF,1154,00104,,,ID der Marktlokation,,[950] Format: Marktlokations-ID + 237,Arbeit / Leistung für tagesparameterabhängige Marktlokation,SG9,,,,,,,,[101] Wenn SG10 CCI+++ZA6 (Prognosegrundlage der Marktlokation: Prognose auf Basis von Profilen) CAV+E14/ Z36 (TLP/ TEP/ TEP mit Ref.messung) in dieser SG8 vorhanden + 238,Arbeit / Leistung für tagesparameterabhängige Marktlokation,SG9,QTY,,00105,,,,, + 239,Arbeit / Leistung für tagesparameterabhängige Marktlokation,SG9,QTY,6063,00105,265,,VeranschlagteJahresmenge Gesamt/Jahresverbrauchsprognose für spezifische Arbeitfürtagesparameterabhängige Marktlokation,, + 240,Arbeit / Leistung für tagesparameterabhängige Marktlokation,SG9,QTY,6063,,Z08,,"Angepasste elektrischeArbeit nach Anhang Dder VDN-Richtlinie""Lastprofile fürunterbrechbareVerbrauchseinrichtungen""",, + 241,Arbeit / Leistung für tagesparameterabhängige Marktlokation,SG9,QTY,6060,00105,,,Menge,,[902] Format: Möglicher Wert: ≥ 0 + 242,Arbeit / Leistung für tagesparameterabhängige Marktlokation,SG9,QTY,6411,00105,Z16,,kWh/K (Kilowatt-Stunde/Kelvin),, + 243,Arbeit / Leistung für tagesparameterabhängige Marktlokation,SG9,QTY,6411,,KWH,,Kilowattstunde,,"[103] Wenn SG9 QTY+265 (Arbeit / Leistung für tagesparameterabhängig e Marktlokation: Veranschlagte Jahresmenge Gesamt) in dieser SG8 vorhanden + [104] Wenn SG9 QTY+Z08 (Arbeit / Leistung für tagesparameterabhängig e Marktlokation: angepasste elektrische Arbeit nach Anhang D) in dieser SG8 vorhanden" + 244,Veranschlagte Jahresmenge gesamt,SG9,,,,,,,,[106] Wenn in dieser SG8 SEQ+Z01 SG10 CCI+++ZA6 (Prognosegrundlage der Marktlokation: Prognose auf Basis von Profilen) CAV+E02 (SLP/SEP) vorhanden + 245,Veranschlagte Jahresmenge gesamt,SG9,QTY,,00106,,,,, + 246,Veranschlagte Jahresmenge gesamt,SG9,QTY,6063,00106,31,,VeranschlagteJahresmenge Gesamt,, + 247,Veranschlagte Jahresmenge gesamt,SG9,QTY,6060,00106,,,Mengenangabe,,"[902] Format: Möglicher Wert: ≥ 0 + [937] Format: keine Nachkommastelle" + 248,Veranschlagte Jahresmenge gesamt,SG9,QTY,6411,00106,KWH,,Kilowattstunde,, + 249,Lieferrichtung,SG10,,,,,,,Muss, + 250,Lieferrichtung,SG10,CCI,,00110,,,,Muss, + 251,Lieferrichtung,SG10,CCI,7059,00110,Z30,,Lieferrichtung,X, + 252,Lieferrichtung,SG10,CCI,7037,00110,Z07,,Verbrauch,X, + 253,Zugeordnete Marktpartner,SG10,,,,,,,, + 254,Zugeordnete Marktpartner,SG10,CCI,,00111,,,,, + 255,Zugeordnete Marktpartner,SG10,CCI,7037,00111,ZB3,,ZugeordneterMarktpartner,, + 256,Übertragungsnetzbetreiber,SG10,CAV,,00114,,,,, + 257,Übertragungsnetzbetreiber,SG10,CAV,7111,00114,Z90,,ÜNB,, + 258,Übertragungsnetzbetreiber,SG10,CAV,1131,00114,,,MP-ID,, + 259,Messstellenbetreiber,SG10,CAV,,00115,,,,,"[232] Wenn SG10 CCI+++Z83 CAV+Z52 (Messtechnische Einordnung der Marktlokation: iMS) vorhanden + [234] Wenn SG10 CCI+++Z83 (Messtechnische Einordnung der Marktlokation) CAV+Z53 (kME/ mME) vorhanden" + 260,Messstellenbetreiber,SG10,CAV,7111,00115,Z91,,MSB,, + 261,Messstellenbetreiber,SG10,CAV,1131,00115,,,MP-ID,, + 262,Messstellenbetreiber,SG10,CAV,7110,00115,Z19,,Auf vertraglicherGrundlage gegenüberAnschlussnutzer /Anschlussnehmer,, + 263,Messstellenbetreiber,SG10,CAV,7110,,Z20,,In der Ausübung derWeiterverpflichtungdurch den gMSB,, + 264,Messstellenbetreiber,SG10,CAV,7110,00115,Z39,,GrundzuständigerMessstellenbetreiber,, + 265,Messstellenbetreiber,SG10,CAV,7110,,Z40,,WettbewerblicherMessstellenbetreiber,, + 266,Messstellenbetreiber,SG10,CAV,7110,,Z41,,Auffangmessstellenbetreiber,, + 267,Regelzone,SG10,,,,,,,, + 268,Regelzone,SG10,CCI,,00116,,,,, + 269,Regelzone,SG10,CCI,7059,00116,Z18,,Regelzone,, + 270,Regelzone,SG10,CCI,7037,00116,,,Regelzone,, + 271,Bilanzkreis,SG10,,,,,,,,[64] Wenn SG4 DTM+158 (Bilanzierungsbeginn) vorhanden + 272,Bilanzkreis,SG10,CCI,,00117,,,,, + 273,Bilanzkreis,SG10,CCI,7059,00117,Z19,,Bilanzkreis,, + 274,Bilanzkreis,SG10,CCI,7037,00117,,,Bilanzkreis,, + 275,Bilanzierungsgebiet,SG10,,,,,,,, + 276,Bilanzierungsgebiet,SG10,CCI,,00118,,,,, + 277,Bilanzierungsgebiet,SG10,CCI,7059,00118,Z20,,Bilanzierungsgebiet,, + 278,Bilanzierungsgebiet,SG10,CCI,7037,00118,,,Bilanzierungsgebiet,, + 279,Verbrauchsaufteilung für temperaturabhängige Marktlokation,SG10,,,,,,,,"[89] Wenn im SG8 SEQ+Z01 (Daten der Marktlokation) das SG10 CCI+++ZA6 (Prognosegrundlage der Marktlokation: Prognose auf Basis von Profilen) CAV+E14 (TLP/TEP) vorhanden + [106] Wenn in dieser SG8 SEQ+Z01 SG10 CCI+++ZA6 (Prognosegrundlage der Marktlokation: Prognose auf Basis von Profilen) CAV+E02 (SLP/SEP) vorhanden" + 280,Verbrauchsaufteilung für temperaturabhängige Marktlokation,SG10,CCI,,00119,,,,, + 281,Verbrauchsaufteilung für temperaturabhängige Marktlokation,SG10,CCI,7037,00119,E17,,Verbrauchsaufteilung (in%) fürtemperaturabhängigeMarktlokation,, + 282,Verbrauchsaufteilung für temperaturabhängige Marktlokation,SG10,CAV,,00120,,,,, + 283,Verbrauchsaufteilung für temperaturabhängige Marktlokation,SG10,CAV,7111,00120,Z22,,Verbrauchsaufteilung in%,, + 284,Verbrauchsaufteilung für temperaturabhängige Marktlokation,SG10,CAV,7110,00120,,,Verbrauchsaufteilung in %,,[902] Format: Möglicher Wert: ≥ 0 + 285,Zeitreihentyp,SG10,,,,,,,,[90] Wenn SG10 CCI+++ZA6 (Prognosegrundlage der Marktlokation: Prognose + 286,Zeitreihentyp,SG10,CCI,,00121,,,,, + 287,Zeitreihentyp,SG10,CCI,7059,00121,15,,Struktur,, + 288,Zeitreihentyp,SG10,CCI,7037,00121,Z21,,Summenzeitreihentyp,, + 289,Zeitreihentyp,SG10,CAV,,00122,,,,, + 290,Zeitreihentyp,SG10,CAV,7111,00122,,,Code des Zeitreihentyps,, + 291,Spannungsebene der Marktlokation,SG10,,,,,,,, + 292,Spannungsebene der Marktlokation,SG10,CCI,,00123,,,,, + 293,Spannungsebene der Marktlokation,SG10,CCI,7037,00123,E03,,Spannungsebene derMarktlokation,, + 294,Spannungsebene der Marktlokation,SG10,CAV,,00124,,,,, + 295,Spannungsebene der Marktlokation,SG10,CAV,7111,00124,E03,,Höchstspannung,, + 296,Spannungsebene der Marktlokation,SG10,CAV,7111,,E04,,Hochspannung,, + 297,Spannungsebene der Marktlokation,SG10,CAV,7111,,E05,,Mittelspannung,, + 298,Spannungsebene der Marktlokation,SG10,CAV,7111,,E06,,Niederspannung,, + 299,Umspannung der Marktlokation,SG10,CAV,,00125,,,,,[166] Wenn vorhanden + 300,Umspannung der Marktlokation,SG10,CAV,7111,00125,E07,,Hös/HS Umspannung,, + 301,Umspannung der Marktlokation,SG10,CAV,7111,,E08,,HS/MS Umspannung,, + 302,Umspannung der Marktlokation,SG10,CAV,7111,,E09,,MS/NS Umspannung,,"[114] Wenn das SG10 CCI+E03 (Spannungsebene der Marktlokation) CAV E06 (Niederspannung) in dieser SG vorhanden + [115] Wenn das SG10 CCI+E03 (Spannungsebene der Marktlokation) CAV E05 (Mittelspannung) in dieser SG vorhanden " + 303,Messtechnische Einordnung der Marktlokation,SG10,,,,,,,, + 304,Messtechnische Einordnung der Marktlokation,SG10,CCI,,00126,,,,, + 305,Messtechnische Einordnung der Marktlokation,SG10,CCI,7037,00126,Z83,,MesstechnischeEinordnung derMarktlokation,, + 306,Messtechnische Einordnung der Marktlokation,SG10,CAV,,00127,,,,, + 307,Messtechnische Einordnung der Marktlokation,SG10,CAV,7111,00127,Z52,,iMS,, + 308,Messtechnische Einordnung der Marktlokation,SG10,CAV,7111,,Z53,,kME / mME,, + 309,Messtechnische Einordnung der Marktlokation,SG10,CAV,7111,,Z68,,keine Messung,, + 310,Aggregationsverantwortung in MaBiS,SG10,,,,,,,, + 311,Aggregationsverantwortung in MaBiS,SG10,CCI,,00128,,,,, + 312,Aggregationsverantwortung in MaBiS,SG10,CCI,7059,00128,6,,Verantwortlicher,, + 313,Aggregationsverantwortung in MaBiS,SG10,CCI,7037,00128,ZA8,,NB,, + 314,Aggregationsverantwortung in MaBiS,SG10,CCI,7037,,ZA9,,ÜNB,, + 315,Prognosegrundlage der Marktlokation,SG10,,,,,,,, + 316,Prognosegrundlage der Marktlokation,SG10,CCI,,00130,,,,, + 317,Prognosegrundlage der Marktlokation,SG10,CCI,7037,00130,ZC0,,Prognose auf Basis vonWerten,, + 318,Prognosegrundlage der Marktlokation,SG10,CCI,7037,,ZA6,,Prognose auf Basis vonProfilen,, + 319,Details der Prognosegrundlage,SG10,CAV,,00131,,,,,"[21] Wenn SG10 CCI+++ZA6 (Prognose auf Basis von Profilen) in dieser SG8 vorhanden + [90] Wenn SG10 CCI+++ZA6 (Prognosegrundlage der Marktlokation: Prognose auf Basis von Profilen) einmal mit CAV+E14 (TLP/TEP) und einmal mit CAV+E02 (SLP/SEP) in dieser SG8 vorhanden" + 320,Details der Prognosegrundlage,SG10,CAV,7111,00131,E02,,SLP/SEP,, + 321,Details der Prognosegrundlage,SG10,CAV,7111,,E14,,TLP/TEP,, + 322,Wahlrecht der Prognosegrundlage der Marktlokation,SG10,,,,,,,,[244] Wenn SG10 CCI+6++ZA9 (Aggreg. verantw. ÜNB) in dieser SG8 vorhanden + 323,Wahlrecht der Prognosegrundlage der Marktlokation,SG10,CCI,,00134,,,,, + 324,Wahlrecht der Prognosegrundlage der Marktlokation,SG10,CCI,7037,00134,Z84,,Wahlrecht derPrognosegrundlage,, + 325,Wahlrecht der Prognosegrundlage der Marktlokation,SG10,CAV,,00135,,,,, + 326,Wahlrecht der Prognosegrundlage der Marktlokation,SG10,CAV,7111,00135,Z54,,Wahlrecht durch LFgegeben,, + 327,Wahlrecht der Prognosegrundlage der Marktlokation,SG10,CAV,7111,,ZE2,,Wahlrecht durch LF nichtgegeben,, + 328,Grund für nicht vorhandenes Wahlrecht der Prognosegrundlage der Marktlokation,SG10,CAV,,00136,,,,,[247] Wenn CAV+ZE2 (Wahlrecht durch LF nicht gegeben) vorhanden + 329,Grund für nicht vorhandenes Wahlrecht der Prognosegrundlage der Marktlokation,SG10,CAV,7111,00136,Z55,,Wahlrecht nichtvorhanden wegenVerbrauch > 10.000kWh/a,, + 330,Grund für nicht vorhandenes Wahlrecht der Prognosegrundlage der Marktlokation,SG10,CAV,7111,,ZC1,,Wahlrecht nichtvorhanden wegenEigenverbrauch,, + 331,Grund für nicht vorhandenes Wahlrecht der Prognosegrundlage der Marktlokation,SG10,CAV,7111,,ZD2,,Wahlrecht nichtvorhanden wegentagesparameterabhängigem Verbrauch,, + 332,Gruppenzuordnung (nach EnWG) ,SG10,,,,,,,, + 333,Gruppenzuordnung (nach EnWG) ,SG10,CCI,,00139,,,,, + 334,Gruppenzuordnung (nach EnWG) ,SG10,CCI,7037,00139,Z15,,Haushaltskunde gem.EnWG,, + 335,Gruppenzuordnung (nach EnWG) ,SG10,CCI,7037,,Z18,,Kein Haushaltskundegem. EnWG,, + 336,Netznutzung,SG10,,,,,,,, + 337,Netznutzung,SG10,CCI,,00140,,,,, + 338,Netznutzung,SG10,CCI,7037,00140,Z88,,Netznutzung,, + 339,Netznutzungsvertrag,SG10,CAV,,00141,,,,, + 340,Netznutzungsvertrag,SG10,CAV,7111,00141,Z74,,Netznutzungsvertrag,, + 341,Netznutzungsvertrag,SG10,CAV,7110,00141,Z08,,Direkter Vertragzwischen Kunden und NB,, + 342,Netznutzungsvertrag,SG10,CAV,7110,,Z09,,Vertrag zwischenLieferanten und NB,, + 343,Zahlung der Netznutzung,SG10,CAV,,00142,,,,, + 344,Zahlung der Netznutzung,SG10,CAV,7111,00142,Z73,,Zahlung der Netznutzung,, + 345,Zahlung der Netznutzung,SG10,CAV,7110,00142,Z10,,Kunde,, + 346,Zahlung der Netznutzung,SG10,CAV,7110,,Z11,,Lieferant,,[216] Wenn CCI+++Z88 (Netznutzung) CAV+Z74:::Z08 (Netznutzungsvertrag: Direkter Vertrag zwischen Kunden und NB) vorhanden + 347,Netznutzungsabrechnungsv ariante,SG10,CAV,,00143,,,,, + 348,Netznutzungsabrechnungsv ariante,SG10,CAV,7111,00143,ZB1,,Netznutzungsabrechnungsvariante,, + 349,Netznutzungsabrechnungsv ariante,SG10,CAV,7110,00143,Z14,,Arbeitspreis/Grundpreis,, + 350,Netznutzungsabrechnungsv ariante,SG10,CAV,7110,,Z15,,Arbeitspreis/Leistungspreis,, + 351,Grundlage der Lieferscheinprüfung,SG10,CAV,,00144,,,,, + 352,Grundlage der Lieferscheinprüfung,SG10,CAV,7111,00144,ZA7,,Grundlage fürLieferscheinprüfung,, + 353,Grundlage der Lieferscheinprüfung,SG10,CAV,7110,00144,Z12,,In derMarktkommunikation,, + 354,Abwicklungsmodell,SG10,,,,,,,, + 355,Abwicklungsmodell,SG10,CCI,,00153,,,,, + 356,Abwicklungsmodell,SG10,CCI,7059,00153,ZA2,,Abwicklungsmodell,, + 357,Abwicklungsmodell,SG10,CCI,7037,00153,ZE9,,"Modell 1 ""Bilanzierungan der Marktlokation""",, + 358,Netznutzungsabrechnungsd aten der Marktlokation,SG8,,,,,,,,[225] Wenn CCI+++Z88 (Netznutzung) CAV+Z73:::Z11 (Zahlung der Netznutzung: Lieferant) vorhanden + 359,Netznutzungsabrechnungsd aten der Marktlokation,SG8,SEQ,,00170,,,,, + 360,Netznutzungsabrechnungsd aten der Marktlokation,SG8,SEQ,1229,00170,Z45,,Netznutzungsabrechnungsdaten derMarktlokation,, + 361,Gruppenartikel-ID / Artikel- ID,SG8,PIA,,00171,,,,, + 362,Gruppenartikel-ID / Artikel- ID,SG8,PIA,4347,00171,Z02,,Gruppenartikel-ID /Artikel-ID,, + 363,Gruppenartikel-ID / Artikel- ID,SG8,PIA,7140,00171,,,Produkt-/Leistungsnummer,,"[259] Wenn in diesem PIA der Code im DE7140 mit 1-01, 1-03, 1-05 enthalten ist + [261] Wenn in diesem PIA der Code im DE7140 mit 1-07-1/2, 1-10-1/2/ 4/5/6/7/8/9, 1-11-1 beginnt + [270] Wenn in diesem PIA der Code im DE7140 mit 1-02, 1-04, 1-06, 1- 09 beginnt + [282] Wenn in diesem PIA der Code im DE7140 1-01-6-005, 1-01-9-001, 1-07-3-001, 1-08-1-001, 1-08-3-001, 1-08-4- 001/002/003/004, 1- 10-3-001 enthalten ist + [284] Erlaubte Codes aus der Codeliste der Gruppenartikel- und" + 364,Gruppenartikel-ID / Artikel- ID,SG8,PIA,7143,00171,Z09,,Artikel-ID,, + 365,Gruppenartikel-ID / Artikel- ID,SG8,PIA,7143,,Z10,,Gruppenartikel-ID,,"[392] Wenn in diesem PIA der Code im Format n1-n2-n1 angegeben ist + [393] Wenn in diesem PIA der Code im Format n1-n2-n1-n3 angegeben ist + [394] Wenn in diesem PIA der Code im Format n1-n2-n1-n8-n2 angegeben ist + [395] Wenn in diesem PIA der Code im Format n1-n2-n1-n8 angegeben ist + [397] Wenn in diesem PIA der Code im DE7140 mit 1-08-1/1-08-4 beginnt + [398] Wenn in diesem PIA der Code im DE7140 mit 1-08-2/1-08-5" + 366,Anzahl in der NNA abzurechenden Positionen der Gruppenartikel-ID / Artikel-ID,SG9,,,,,,,,[237] Wenn in derselben SG8 im DE7140 des PIA+Z02 (Gruppenartikel-ID / Artikel-ID) eine Gruppenartikel-ID / Artikel-ID mit 1-06 (entspricht Entgelte des Messstellenbetriebs bei kME) beginnt + 367,Anzahl in der NNA abzurechenden Positionen der Gruppenartikel-ID / Artikel-ID,SG9,QTY,,00172,,,,, + 368,Anzahl in der NNA abzurechenden Positionen der Gruppenartikel-ID / Artikel-ID,SG9,QTY,6063,00172,Z38,,Anzahl derabzurechendenPositionen derGruppenartikel-ID /Artikel-ID,, + 369,Anzahl in der NNA abzurechenden Positionen der Gruppenartikel-ID / Artikel-ID,SG9,QTY,6060,00172,,,Menge,,"[914] Format: Möglicher Wert: > 0 + [937] Format: keine Nachkommastelle" + 370,Anzahl in der NNA abzurechenden Positionen der Gruppenartikel-ID / Artikel-ID,SG9,QTY,6411,00172,PCS,,Stück,, + 371,Gemeinderabatt,SG9,,,,,,,, + 372,Gemeinderabatt,SG9,QTY,,00173,,,,, + 373,Gemeinderabatt,SG9,QTY,6063,00173,Z16,,Gemeinderabatt,, + 374,Gemeinderabatt,SG9,QTY,6060,00173,,,Menge,,"[902] Format: Möglicher Wert: ≥ 0 + [930] Format: max. 2 Nachkommastellen + [938] Format: Möglicher Wert: <= 10" + 375,Gemeinderabatt,SG9,QTY,6411,00173,P1,,Prozent,, + 376,Zuschlag oder Abschlag,SG9,,,,,,,, + 377,Zuschlag oder Abschlag,SG9,QTY,,00174,,,,, + 378,Zuschlag oder Abschlag,SG9,QTY,6063,00174,Z34,,Zuschlag,, + 379,Zuschlag oder Abschlag,SG9,QTY,6063,,Z35,,Abschlag,, + 380,Zuschlag oder Abschlag,SG9,QTY,6063,,Z37,,Kein Zu-/Abschlag,, + 381,Zuschlag oder Abschlag,SG9,QTY,6060,00174,,,Menge,,"[140] Wenn im selben QTY im DE6063 Z34/Z35 (Zuschlag/Abschlag) vorhanden + [172] Wenn im selben QTY im DE6063 Z37 (Kein Zu- und Abschlag)" + 382,Zuschlag oder Abschlag,SG9,QTY,6411,00174,P1,,Prozent,, + 383,Menge der Singulär genutzten Betriebsmittel,SG9,,,,,,,,"[73] Wenn in derselben SG8 im PIA DE7140 ein Code aus der Codeliste der Gruppenartikel- und Artikel-ID vorhanden ist, der in der Spalte UTILMD/Preisangabe mit X gekennzeichnet ist" + 384,Menge der Singulär genutzten Betriebsmittel,SG9,QTY,,00175,,,,, + 385,Menge der Singulär genutzten Betriebsmittel,SG9,QTY,6063,00175,Z33,,Singulär genutzteBetriebsmittel,, + 386,Menge der Singulär genutzten Betriebsmittel,SG9,QTY,6060,00175,,,Menge,, + 387,Preisangabe für Singulär genutzte Betriebsmittel,SG10,,,,,,,,"[73] Wenn in derselben SG8 im PIA DE7140 ein Code aus der Codeliste der Gruppenartikel- und Artikel-ID vorhanden ist, der in der Spalte UTILMD/Preisangabe mit X gekennzeichnet ist" + 388,Preisangabe für Singulär genutzte Betriebsmittel,SG10,CCI,,00176,,,,, + 389,Preisangabe für Singulär genutzte Betriebsmittel,SG10,CCI,7059,00176,Z44,,Berechnungspreis,, + 390,Preisangabe für Singulär genutzte Betriebsmittel,SG10,CCI,7037,00176,ZD8,,Tag,, + 391,Preisangabe für Singulär genutzte Betriebsmittel,SG10,CCI,7036,00176,,,"Preis, Betrag",,"[914] Format: Möglicher Wert: > 0 + [946] Format: max. 11 Nachkommastellen" + 392,Zugeordnete Zählzeitdefinition,SG10,,,,,,,,[59] Wenn mehr als eine SG8 SEQ+Z45 (Netznutzungsabrechnun gsdaten der Marktlokation) mit einer Gruppen-/Artikel-ID im + 393,Zugeordnete Zählzeitdefinition,SG10,CCI,,00177,,,,, + 394,Zugeordnete Zählzeitdefinition,SG10,CCI,7059,00177,Z39,,Code derZählzeitdefinition,, + 395,Zugeordnete Zählzeitdefinition,SG10,CCI,7037,00177,,,Code der Zählzeitdefinition,, + 396,Zugeordnetes Zählzeitregister ,SG10,,,,,,,,"[59] Wenn mehr als eine SG8 SEQ+Z45 (Netznutzungsabrechnun gsdaten der Marktlokation) mit einer Gruppen-/Artikel-ID im SG8 PIA+Z02 (Gruppenartikel-ID / Artikel-ID), welche mit 1-08-1/2/3/4/5 beginnt, vorhanden + [108] Wenn in derselben SG8 SEQ+Z45 (Netznutzungsabrechnun gsdaten der Marktlokation) eine Gruppen-/Artikel-ID im SG8 PIA+Z02 (Gruppenartikel-ID / Artikel-ID), welche mit 1-08-1/2/3/4/5 beginnt, vorhanden" + 397,Zugeordnetes Zählzeitregister ,SG10,CCI,,00178,,,,, + 398,Zugeordnetes Zählzeitregister ,SG10,CCI,7059,00178,Z38,,Code desZählzeitregisters,, + 399,Zugeordnetes Zählzeitregister ,SG10,CCI,7037,00178,,,Code des Zählzeitregisters,, + 400,OBIS-Daten der Marktlokation,SG8,,,,,,,, + 401,OBIS-Daten der Marktlokation,SG8,SEQ,,00198,,,,, + 402,OBIS-Daten der Marktlokation,SG8,SEQ,1229,00198,Z02,,OBIS-Daten der,, + 403,Referenz auf die ID der Marktlokation,SG8,RFF,,00199,,,,, + 404,Referenz auf die ID der Marktlokation,SG8,RFF,1153,00199,Z18,,Marktlokation,, + 405,Referenz auf die ID der Marktlokation,SG8,RFF,1154,00199,,,ID einer Marktlokation,,[950] Format: Marktlokations-ID + 406,OBIS-Kennzahl der Marktlokation,SG8,PIA,,00200,,,,, + 407,OBIS-Kennzahl der Marktlokation,SG8,PIA,4347,00200,5,,Produktidentifikation,, + 408,OBIS-Kennzahl der Marktlokation,SG8,PIA,7140,00200,,,OBIS-Kennzahl der Marktlokation,,"[314] Es sind alle OBIS- Kennzahlen gem. EDI@Energy Codeliste der OBIS-Kennzahlen und Medien für den deutschen Energiemarkt Kap. 3 anzugeben, welche an der Marktlokation erforderlich sind. Der Mindestumfang der OBIS-Kennzahlen ergibt sich aus den genannten Messprodukt-Codes dem Kap. 5.1 des Dokumentes ""Codeliste der Konfigurationen""" + 409,OBIS-Kennzahl der Marktlokation,SG8,PIA,7143,00200,SRW,,OBIS-Kennzahl,, + 410,Wertegranularität,SG10,,,,,,,,[257] Wenn in derselben SG8 SEQ+Z02 (OBIS- Daten der Marktlokation) das PIA+5+1-b?:1.9.e vorhanden + 411,Wertegranularität,SG10,CCI,,00201,,,,, + 412,Wertegranularität,SG10,CCI,7037,00201,ZE4,,Wertegranularität,, + 413,Wertegranularität,SG10,CAV,,00202,,,,, + 414,Wertegranularität,SG10,CAV,7111,00202,ZD9,,Jährlich,, + 415,Wertegranularität,SG10,CAV,7111,,ZE8,,Halbjährlich,, + 416,Wertegranularität,SG10,CAV,7111,,ZE9,,Quartalsweise,, + 417,Wertegranularität,SG10,CAV,7111,,ZB7,,Monatlich,, + 418,Zugeordnete Zählzeitdefinition,SG10,,,,,,,,[386] Wenn mehr als eine SG8 SEQ+Z02 (OBIS-Daten der + 419,Zugeordnete Zählzeitdefinition,SG10,CCI,,00203,,,,, + 420,Zugeordnete Zählzeitdefinition,SG10,CCI,7059,00203,Z39,,Code derZählzeitdefinition,, + 421,Zugeordnete Zählzeitdefinition,SG10,CCI,7037,00203,,,Code der Zählzeitdefinition,, + 422,Zugeordnetes Zählzeitregister ,SG10,,,,,,,,[421] Wenn in dieser SG8 das SG10 CCI+Z39 (Zugeordnete Zählzeitdefinition) vorhanden ist + 423,Zugeordnetes Zählzeitregister ,SG10,CCI,,00204,,,,, + 424,Zugeordnetes Zählzeitregister ,SG10,CCI,7059,00204,Z38,,Code desZählzeitregisters,, + 425,Zugeordnetes Zählzeitregister ,SG10,CCI,7037,00204,,,Code des Zählzeitregisters,, + 426,OBIS Daten für Lieferant relevant,SG10,,,,,,,, + 427,OBIS Daten für Lieferant relevant,SG10,CCI,,00207,,,,, + 428,OBIS Daten für Lieferant relevant,SG10,CCI,7037,00207,ZA7,,LF,, + 429,Verwendungszweck der Werte,SG10,CAV,,00208,,,,, + 430,Verwendungszweck der Werte,SG10,CAV,7111,00208,Z84,,Netznutzungsabrechnun,, + 431,Verwendungszweck der Werte,SG10,CAV,7111,,Z85,,Bilanzkreisabrechnung,, + 432,Verwendungszweck der Werte,SG10,CAV,7111,,Z86,,Mehrmindermengenabrechnung,, + 433,Verwendungszweck der Werte,SG10,CAV,7111,,Z47,,Endkundenabrechnung,, + 434,Produkt-Daten der Marktlokation,SG8,,,,,,,,[166] Wenn vorhanden + 435,Produkt-Daten der Marktlokation,SG8,SEQ,,00211,,,,, + 436,Produkt-Daten der Marktlokation,SG8,SEQ,1229,00211,Z59,,Produkt-Daten derMarktlokation,, + 437,Referenz auf die ID der Marktlokation,SG8,RFF,,00212,,,,, + 438,Referenz auf die ID der Marktlokation,SG8,RFF,1153,00212,Z18,,Marktlokation,, + 439,Referenz auf die ID der Marktlokation,SG8,RFF,1154,00212,,,ID einer Marktlokation,,[950] Format: Marktlokations-ID + 440,Produkt-Daten der Marktlokation,SG8,PIA,,00213,,,,, + 441,Produkt-Daten der Marktlokation,SG8,PIA,4347,00213,5,,Produktidentifikation,, + 442,Produkt-Daten der Marktlokation,SG8,PIA,7140,00213,,,Produkt-/Leistungsnummer,, + 443,Produkt-Daten der Marktlokation,SG8,PIA,7143,00213,Z12,,Konfigurationsprodukt,, + 444,Zugeordnete Definition,SG10,,,,,,,, + 445,Zugeordnete Definition,SG10,CCI,,00214,,,,, + 446,Zugeordnete Definition,SG10,CCI,7059,00214,Z53,,Code derLeistungskurvendefinition,, + 447,Zugeordnete Definition,SG10,CCI,7037,00214,,,Code der Definition,, + 448,Produkt-Daten für Marktrolle relevant,SG10,,,,,,,, + 449,Produkt-Daten für Marktrolle relevant,SG10,CCI,,00215,,,,, + 450,Produkt-Daten für Marktrolle relevant,SG10,CCI,7037,00215,ZA7,,LF,, + 451,Verbrauchsart und Nutzung der OBIS-Kennzahl der Marktlokation,SG8,,,,,,,,[298] Wenn SG5 LOC+Z20 (Technische Ressource) nicht vorhanden + 452,Verbrauchsart und Nutzung der OBIS-Kennzahl der Marktlokation,SG8,SEQ,,00216,,,,, + 453,Verbrauchsart und Nutzung der OBIS-Kennzahl der Marktlokation,SG8,SEQ,1229,00216,Z44,,Verbrauchsart undNutzung der OBIS-Kennzahl an derMarktlokation,, + 454,Referenz auf die OBIS- Kennzahl der Marktlokation,SG8,RFF,,00217,,,,, + 455,Referenz auf die OBIS- Kennzahl der Marktlokation,SG8,RFF,1153,00217,Z10,,OBIS-Kennzahl,, + 456,Referenz auf die OBIS- Kennzahl der Marktlokation,SG8,RFF,1154,00217,,,OBIS-Kennzahl,, + 457,Verbrauchsart und Nutzung an der OBIS-Kennzahl der Marktlokation,SG10,,,,,,,, + 458,Verbrauchsart und Nutzung an der OBIS-Kennzahl der Marktlokation,SG10,CCI,,00218,,,,, + 459,Verbrauchsart und Nutzung an der OBIS-Kennzahl der Marktlokation,SG10,CCI,7059,00218,Z17,,Stromverbrauchsart,, + 460,Verbrauchsart,SG10,CAV,,00219,,,,, + 461,Verbrauchsart,SG10,CAV,7111,00219,Z64,,Kraft/Licht,, + 462,Verbrauchsart,SG10,CAV,7111,,Z65,,Wärme,, + 463,Verbrauchsart,SG10,CAV,7111,,ZE5,,E-Mobilität,, + 464,Verbrauchsart,SG10,CAV,7111,,ZA8,,Straßenbeleuchtung,, + 465,Verbrauchsart,SG10,CAV,7111,,ZB3,,SteuerungWärmeabgabe,, + 466,Unterbrechbarkeit,SG10,CAV,,00220,,,,, + 467,Unterbrechbarkeit,SG10,CAV,7111,00220,Z62,,unterbrechbareVerbrauchseinrichtung,, + 468,Unterbrechbarkeit,SG10,CAV,7111,,Z63,,nicht-unterbrechbareVerbrauchseinrichtung,, + 469,Wärmenutzung,SG10,CAV,,00221,,,,,[239] Wenn in derselben SG10 das CCI+Z17 (Stromverbrauchsart) im CAV+Z65 (Wärme) vorhanden + 470,Wärmenutzung,SG10,CAV,7111,00221,Z56,,Speicherheizung,, + 471,Wärmenutzung,SG10,CAV,7111,,Z57,,Wärmepumpe,, + 472,Wärmenutzung,SG10,CAV,7111,,Z61,,Direktheizung,, + 473,Art der E-Mobilität,SG10,CAV,,00222,,,,,[95] Wenn in derselben SG10 das CCI+Z17 (Stromverbrauchsart) CAV+ZE5 (E-Mobilität) vorhanden + 474,Art der E-Mobilität,SG10,CAV,7111,00222,ZE6,,Wallbox,, + 475,Art der E-Mobilität,SG10,CAV,7111,,Z87,,E-Mobilitätsladesäule,, + 476,Art der E-Mobilität,SG10,CAV,7111,,ZE7,,Ladepark,, + 477,Konzessionsabgabedaten,SG8,,,,,,,,"[127] Hat der Lieferant auf Grund seines Vertrags Kenntnis, dass der Kunde keine hohe KA hat so muss er dies dem NB mitteilen" + 478,Konzessionsabgabedaten,SG8,SEQ,,00229,,,,, + 479,Konzessionsabgabedaten,SG8,SEQ,1229,00229,Z07,,Konzessionsabgabedaten,, + 480,Zuordnung Konzessionsabgabe,SG10,,,,,,,, + 481,Zuordnung Konzessionsabgabe,SG10,CCI,,00231,,,,, + 482,Zuordnung Konzessionsabgabe,SG10,CCI,7037,00231,Z08,,Konzessionsabgabe,, + 483,Konzessionsabgabe,SG10,CAV,,00232,,,,, + 484,Konzessionsabgabe,SG10,CAV,7111,00232,KAS,,"für allekonzessionsvertraglichenSonderregelungen, dienicht in die Systematikder KAV eingegliedertsind",, + 485,Konzessionsabgabe,SG10,CAV,7111,,SA,,"Sondervertragskunden <1 kV nach § 2 (7) und > 1kV, Preis nach § 2 (3) (fürStrom 0,11 ct/kWh undfür Gas 0,03 ct/kWh)",, + 486,Konzessionsabgabe,SG10,CAV,7111,,SAS,,"Kennzeichnung, dass einabweichender Preis fürSondervertragskundenvorliegt",, + 487,Konzessionsabgabe,SG10,CAV,7111,,TAS,,"Kennzeichnung, dass einabweichender Preis fürTarifkunden vorliegt",, + 488,Konzessionsabgabe,SG10,CAV,7111,,TKS,,"Kennzeichnung, wennnach KAV § 2 (2) 2a einanderer Preis zuverwenden ist",, + 489,Konzessionsabgabe,SG10,CAV,7111,,TS,,"für Strom mitSchwachlast § 2. (2) 1aNT (niedrige KA, 0,61ct/kWh)",, + 490,Konzessionsabgabe,SG10,CAV,7111,,TSS,,"Kennzeichnung, dass einabweichender Preis fürSchwachlast angewendetwird",, + 491,Konzessionsabgabe,SG10,CAV,7110,00232,,,Konzessionsabgabe in Euro/kWh,,"[129] Hat der Lieferant auf Grund seines Vertrags Kenntnis über die Höhe der Sonder-KA, so muss er diesen dem NB mitteilen + [902] Format: Möglicher Wert: ≥ 0 + [912] Format: max. 6 Nachkommastellen + [914] Format: Möglicher Wert: > 0" + 492,Konzessionsabgabe,SG10,CAV,7110,00232,,,Gebührenkategorie derKonzessionsabgabe,, + 493,Steuer-/ Abgabeninformation,SG8,,,,,,,, + 494,Steuer-/ Abgabeninformation,SG8,SEQ,,00233,,,,, + 495,Steuer-/ Abgabeninformation,SG8,SEQ,1229,00233,Z10,,Steuer-/Abgabeninformation,, + 496,Steuern-/Abgabenbefreiung,SG10,,,,,,,, + 497,Steuern-/Abgabenbefreiung,SG10,CCI,,00235,,,,, + 498,Steuern-/Abgabenbefreiung,SG10,CCI,7059,00235,Z13,,Steuerinformation,, + 499,Steuern-/Abgabenbefreiung,SG10,CCI,7037,00235,Z65,,Stromsteuer befreit,, + 500,Steuern-/Abgabenbefreiung,SG10,CCI,7037,,Z66,,Stromsteuer pflichtig,, + 501,Gemeinderabatt,SG8,,,,,,,, + 502,Gemeinderabatt,SG8,SEQ,,00236,,,,, + 503,Gemeinderabatt,SG8,SEQ,1229,00236,Z12,,Gemeinderabatt,, + 504,Gemeinderabatt,SG9,,,,,,,, + 505,Gemeinderabatt,SG9,QTY,,00237,,,,, + 506,Gemeinderabatt,SG9,QTY,6063,00237,Z16,,Gemeinderabatt,, + 507,Gemeinderabatt,SG9,QTY,6060,00237,,,Menge,,"[902] Format: Möglicher Wert: ≥ 0 + [930] Format: max. 2 Nachkommastellen + [938] Format: Möglicher Wert: <= 10" + 508,Gemeinderabatt,SG9,QTY,6411,00237,P1,,Prozent,, + 509,Daten der Technischen Ressource,SG8,,,,,,,,"[296] Wenn SG5 LOC+Z20 (Technische Ressource) vorhanden + [2357] Je SG5 LOC+Z20 (Technische Ressource) ist genau einmal die Segmentgruppe anzugeben" + 510,Daten der Technischen Ressource,SG8,SEQ,,00273,,,,, + 511,Daten der Technischen Ressource,SG8,SEQ,1229,00273,Z52,,Daten der TechnischenRessource,, + 512,Referenz auf die ID der Technischen Ressource,SG8,RFF,,00274,,,,, + 513,Referenz auf die ID der Technischen Ressource,SG8,RFF,1153,00274,Z37,,Technische Ressource,, + 514,Referenz auf die ID der Technischen Ressource,SG8,RFF,1154,00274,,,ID der Technischen Ressource,,[922] Format: TR-ID + 515,Referenz auf die ID der vorgelagerten Messlokation,SG8,RFF,,00275,,,,,"[166] Wenn vorhanden + [668] Hinweis: Dieses Segment wird nach Abschluss der Einführung der Lokationsbündelstruktur zum 01.10.2025 aus der UTILMD entfernt" + 516,Referenz auf die ID der vorgelagerten Messlokation,SG8,RFF,1153,00275,Z34,,vorgelagerteMesslokation,, + 517,Referenz auf die ID der vorgelagerten Messlokation,SG8,RFF,1154,00275,,,ID einer Lokation,,[951] Format: Zählpunktbezeichnung + 518,Referenz auf die der Technischen Ressource zugeordneten Marktlokation ,SG8,RFF,,00276,,,,,[668] Hinweis: Dieses Segment wird nach Abschluss der Einführung der Lokationsbündelstruktur zum 01.10.2025 aus der UTILMD entfernt + 519,Referenz auf die der Technischen Ressource zugeordneten Marktlokation ,SG8,RFF,1153,00276,Z16,,zugeordneteMarktlokation,, + 520,Referenz auf die der Technischen Ressource zugeordneten Marktlokation ,SG8,RFF,1154,00276,,,ID der Marktlokation,,[950] Format: Marktlokations-ID + 521,Referenz auf die der Technischen Ressource zugeordneten Steuerbaren Ressource,SG8,RFF,,00277,,,,,"[166] Wenn vorhanden + [699] Hinweis: Es ist die ID der Steuerbare Ressource zu nennen über die die Technische Ressource gesteuert wird" + 522,Referenz auf die der Technischen Ressource zugeordneten Steuerbaren Ressource,SG8,RFF,1153,00277,Z38,,Steuerbare Ressource,, + 523,Referenz auf die der Technischen Ressource zugeordneten Steuerbaren Ressource,SG8,RFF,1154,00277,,,ID der Steuerbaren Ressource,,[961] Format: SR-ID + 524,Referenz auf die der Technischen Ressource zugeordneten Netzlokation,SG8,RFF,,00278,,,,,"[166] Wenn vorhanden + [700] Hinweis: Es ist die ID der Netzlokation zu" + 525,Referenz auf die der Technischen Ressource zugeordneten Netzlokation,SG8,RFF,1153,00278,Z32,,Netzlokation,, + 526,Referenz auf die der Technischen Ressource zugeordneten Netzlokation,SG8,RFF,1154,00278,,,ID der Netzlokation,,[960] Format: Netzlokations-ID + 527,Nennleistung (Aufnahme),SG9,,,,,,,,"[165] Wenn bekannt + [446] Wenn in derselben SG8 das CCI+Z17 (Stromverbrauchsart) vorhanden + [448] Wenn in derselben SG8 das CCI+Z56 (Speicher) vorhanden + [465] Wenn in derselben SG8 SEQ+Z52 (Daten der Technischen Ressource) das RFF+Z38 (Referenz auf die der Technischen Ressource zugeordnete Steuerbare Ressource) vorhanden ist + [466] Wenn in derselben SG8 SEQ+Z52 (Daten der Technischen Ressource) das RFF+Z32 (Referenz auf die der Technischen Ressource zugeordneten Netzlokation) vorhanden ist + [467] Wenn in derselben SG8 SEQ+Z52 (Daten der Technischen Ressource) das CAV+ZG8 (Technischen Ressource fällt unter §14a EnWG) vorhanden ist + [468] Wenn in derselben SG8 SEQ+Z52 (Daten der Technischen Ressource) das SG10 CAV+ZH0 (Inbetriebsetzung der TR nach 2023) vorhanden ist + [469] Wenn in derselben SG8 SEQ+Z52 (Daten der Technischen Ressource)" + 528,Nennleistung (Aufnahme),SG9,QTY,,00279,,,,, + 529,Nennleistung (Aufnahme),SG9,QTY,6063,00279,Z43,,Nennleistung(Aufnahme),, + 530,Nennleistung (Aufnahme),SG9,QTY,6060,00279,,,Menge,, + 531,Nennleistung (Aufnahme),SG9,QTY,6411,00279,KWT,,Kilowatt,, + 532,Nennleistung (Abgabe),SG9,,,,,,,,[448] Wenn in derselben SG8 das CCI+Z56 (Speicher) vorhanden + 533,Nennleistung (Abgabe),SG9,QTY,,00280,,,,, + 534,Nennleistung (Abgabe),SG9,QTY,6063,00280,Z44,,Nennleistung (Abgabe),, + 535,Nennleistung (Abgabe),SG9,QTY,6060,00280,,,Menge,, + 536,Nennleistung (Abgabe),SG9,QTY,6411,00280,KWT,,Kilowatt,, + 537,Speicherkapazität,SG9,,,,,,,,[448] Wenn in derselben SG8 das CCI+Z56 (Speicher) vorhanden + 538,Speicherkapazität,SG9,QTY,,00281,,,,, + 539,Speicherkapazität,SG9,QTY,6063,00281,Z42,,Speicherkapazität,, + 540,Speicherkapazität,SG9,QTY,6060,00281,,,Menge,, + 541,Speicherkapazität,SG9,QTY,6411,00281,KWH,,Kilowattstunde,, + 542,Art und Nutzung der Technischen Ressource,SG10,,,,,,,, + 543,Art und Nutzung der Technischen Ressource,SG10,CCI,,00282,,,,, + 544,Art und Nutzung der Technischen Ressource,SG10,CCI,7059,00282,Z17,,Stromverbrauchsart,, + 545,Art und Nutzung der Technischen Ressource,SG10,CCI,7059,,Z56,,Speicher,, + 546,Verbrauchsart,SG10,CAV,,00283,,,,,[446] Wenn in derselben SG8 das CCI+Z17 (Stromverbrauchsart) vorhanden + 547,Verbrauchsart,SG10,CAV,7111,00283,Z64,,Kraft/Licht,, + 548,Verbrauchsart,SG10,CAV,7111,,Z65,,Wärme,, + 549,Verbrauchsart,SG10,CAV,7111,,ZE5,,E-Mobilität,, + 550,Verbrauchsart,SG10,CAV,7111,,ZA8,,Straßenbeleuchtung,, + 551,Wärmenutzung,SG10,CAV,,00284,,,,,[239] Wenn in derselben SG10 das CCI+Z17 (Stromverbrauchsart) im CAV+Z65 (Wärme) vorhanden + 552,Wärmenutzung,SG10,CAV,7111,00284,Z56,,Speicherheizung,, + 553,Wärmenutzung,SG10,CAV,7111,,Z57,,Wärmepumpe,, + 554,Wärmenutzung,SG10,CAV,7111,,Z61,,Direktheizung,, + 555,Art der E-Mobilität,SG10,CAV,,00285,,,,,[95] Wenn in derselben SG10 das CCI+Z17 (Stromverbrauchsart) CAV+ZE5 (E-Mobilität) vorhanden + 556,Art der E-Mobilität,SG10,CAV,7111,00285,ZE6,,Wallbox,, + 557,Art der E-Mobilität,SG10,CAV,7111,,Z87,,E-Mobilitätsladesäule,, + 558,Art der E-Mobilität,SG10,CAV,7111,,ZE7,,Ladepark,, + 559,Speicherart,SG10,CAV,,00287,,,,,[448] Wenn in derselben SG8 das CCI+Z56 (Speicher) vorhanden + 560,Speicherart,SG10,CAV,7111,00287,ZF7,,Wasserstoffspeicher,, + 561,Speicherart,SG10,CAV,7111,,ZF8,,Pumpspeicher,, + 562,Speicherart,SG10,CAV,7111,,ZF9,,Batteriespeicher,, + 563,Speicherart,SG10,CAV,7111,,ZG6,,Sonstige Speicherart,, + 564,Kategorie der verbrauchenden Technischen Ressource,SG10,CAV,,00288,,,,,"[446] Wenn in derselben SG8 das CCI+Z17 (Stromverbrauchsart) vorhanden + [448] Wenn in derselben SG8 das CCI+Z56 (Speicher) vorhanden" + 565,Kategorie der verbrauchenden Technischen Ressource,SG10,CAV,7111,00288,ZG8,,Technischen Ressourcefällt unter § 14a EnWG,, + 566,Kategorie der verbrauchenden Technischen Ressource,SG10,CAV,7111,,ZG9,,Technischen Ressourcefällt nicht unter § 14aEnWG,, + 567,Inbetriebsetzungsdatum der verbrauchenden Technischen Ressource nach § 14a EnWG,SG10,CAV,,00289,,,,,[461] Wenn in derselben SG10 das CCI+Z17 + 568,Inbetriebsetzungsdatum der verbrauchenden Technischen Ressource nach § 14a EnWG,SG10,CAV,7111,00289,ZH0,,Inbetriebsetzung der TRnach 2023,, + 569,Inbetriebsetzungsdatum der verbrauchenden Technischen Ressource nach § 14a EnWG,SG10,CAV,7111,,ZH1,,Inbetriebsetzung der TRvor 2024,, + 570,Einordnung der verbrauchenden Technischen Ressource nach § 14a EnWG mit Inbetriebsetzung vor 2024,SG10,CAV,,00290,,,,,[462] Wenn in derselben SG10 das CCI+Z17 (Stromverbrauchsart) im CAV+ZH1 (Inbetriebsetzung der TR vor 2024) vorhanden + 571,Einordnung der verbrauchenden Technischen Ressource nach § 14a EnWG mit Inbetriebsetzung vor 2024,SG10,CAV,7111,00290,ZH2,,Wechselmöglichkeit indas § 14a EnWG-Modellgem. Festlegung BK6-22-300 einmalig nochmöglich,, + 572,Einordnung der verbrauchenden Technischen Ressource nach § 14a EnWG mit Inbetriebsetzung vor 2024,SG10,CAV,7111,,ZH3,,Wechselmöglichkeit indas § 14a EnWG-Modellgem. Festlegung BK6-22-300 nicht möglich,, + 573,Einordnung der verbrauchenden Technischen Ressource nach § 14a EnWG mit Inbetriebsetzung vor 2024,SG10,CAV,7111,,ZH4,,Befristet im alten § 14aEnWG-Modell bis 2028ohneWechselmöglichkeit,, + 574,Einordnung der verbrauchenden Technischen Ressource nach § 14a EnWG mit Inbetriebsetzung vor 2024,SG10,CAV,7111,,ZH5,,Wechsel in das § 14aEnWG-Modell gem.Festlegung BK6-22-300wurde durchgeführt,, + 575,Information zu weiteren technischen Einrichtungen,SG10,,,,,,,,"[446] Wenn in derselben SG8 das CCI+Z17 (Stromverbrauchsart) vorhanden + [467] Wenn in derselben SG8 SEQ+Z52 (Daten der Technischen Ressource) das CAV+ZG8 (Technischen Ressource fällt unter §14a EnWG) vorhanden ist" + 576,Information zu weiteren technischen Einrichtungen,SG10,CCI,,00291,,,,, + 577,Information zu weiteren technischen Einrichtungen,SG10,CCI,7059,00291,Z63,,Information zu weiterentechnischen,, + 578,Information zu weiteren technischen Einrichtungen,SG10,CAV,,00292,,,,, + 579,Information zu weiteren technischen Einrichtungen,SG10,CAV,7111,00292,ZH7,,Weitere technischeEinrichtungen vorhanden,, + 580,Information zu weiteren technischen Einrichtungen,SG10,CAV,7111,,ZH8,,Keine weitere technischeEinrichtung vorhanden,, + 581,Daten der Steuerbaren Ressource,SG8,,,,,,,,"[205] Wenn SG5 LOC+Z19 (Steuerbare Ressource) vorhanden + [2358] Je SG5 LOC+Z19 (Steuerbare Ressource) ist genau einmal die Segmentgruppe anzugeben" + 582,Daten der Steuerbaren Ressource,SG8,SEQ,,00293,,,,, + 583,Daten der Steuerbaren Ressource,SG8,SEQ,1229,00293,Z62,,Daten der SteuerbarenRessource,, + 584,Referenz auf die ID der Steuerbaren Ressource,SG8,RFF,,00294,,,,, + 585,Referenz auf die ID der Steuerbaren Ressource,SG8,RFF,1153,00294,Z38,,Steuerbare Ressource,, + 586,Referenz auf die ID der Steuerbaren Ressource,SG8,RFF,1154,00294,,,ID der Steuerbaren Ressource,,[961] Format: SR-ID + 587,Steuerkanal,SG10,,,,,,,, + 588,Steuerkanal,SG10,CCI,,00295,,,,, + 589,Steuerkanal,SG10,CCI,7059,00295,Z49,,Steuerkanal,, + 590,Leistungsbeschreibung des Steuerkanals,SG10,CAV,,00296,,,,, + 591,Leistungsbeschreibung des Steuerkanals,SG10,CAV,7111,00296,ZF2,,Leistungsbeschreibungdes Steuerkanals,, + 592,Leistungsbeschreibung des Steuerkanals,SG10,CAV,1131,00296,Z14,,An/Aus,, + 593,Leistungsbeschreibung des Steuerkanals,SG10,CAV,1131,,Z15,,Gestuft,, + 594,Zugeordnete Marktpartner,SG10,,,,,,,, + 595,Zugeordnete Marktpartner,SG10,CCI,,00297,,,,, + 596,Zugeordnete Marktpartner,SG10,CCI,7037,00297,ZB3,,ZugeordneterMarktpartner,, + 597,Messstellenbetreiber,SG10,CAV,,00298,,,,, + 598,Messstellenbetreiber,SG10,CAV,7111,00298,Z91,,MSB,, + 599,Messstellenbetreiber,SG10,CAV,1131,00298,,,MP-ID,, + 600,Messstellenbetreiber,SG10,CAV,7110,00298,Z39,,GrundzuständigerMessstellenbetreiber,, + 601,Messstellenbetreiber,SG10,CAV,7110,,Z40,,WettbewerblicherMessstellenbetreiber,, + 602,Messstellenbetreiber,SG10,CAV,7110,,Z41,,Auffangmessstellenbetreiber,, + 603,Produkt-Daten der Steuerbaren Ressource,SG8,,,,,,,,"[166] Wenn vorhanden + [205] Wenn SG5 LOC+Z19 (Steuerbare Ressource) vorhanden" + 604,Produkt-Daten der Steuerbaren Ressource,SG8,SEQ,,00299,,,,, + 605,Produkt-Daten der Steuerbaren Ressource,SG8,SEQ,1229,00299,Z61,,Produkt-Daten derSteuerbaren Ressource,, + 606,Referenz auf die ID der Steuerbaren Ressource,SG8,RFF,,00300,,,,, + 607,Referenz auf die ID der Steuerbaren Ressource,SG8,RFF,1153,00300,Z38,,Steuerbare Ressource,, + 608,Referenz auf die ID der Steuerbaren Ressource,SG8,RFF,1154,00300,,,ID einer Steuerbaren Ressource,,[961] Format: SR-ID + 609,Produkt-Daten der Steuerbaren Ressource,SG8,PIA,,00301,,,,, + 610,Produkt-Daten der Steuerbaren Ressource,SG8,PIA,4347,00301,5,,Produktidentifikation,, + 611,Produkt-Daten der Steuerbaren Ressource,SG8,PIA,7140,00301,,,Konfigurationsprodukt-Code,, + 612,Produkt-Daten der Steuerbaren Ressource,SG8,PIA,7143,00301,Z12,,Konfigurationsprodukt,, + 613,Zugeordnete Definition,SG10,,,,,,,, + 614,Zugeordnete Definition,SG10,CCI,,00302,,,,, + 615,Zugeordnete Definition,SG10,CCI,7059,00302,Z52,,Code derSchaltzeitdefinition,, + 616,Zugeordnete Definition,SG10,CCI,7059,,Z53,,Code derLeistungskurvendefinition,, + 617,Zugeordnete Definition,SG10,CCI,7037,00302,,,Code der Definition,, + 618,Auftraggebender Marktpartner,SG10,,,,,,,, + 619,Auftraggebender Marktpartner,SG10,CCI,,00303,,,,, + 620,Auftraggebender Marktpartner,SG10,CCI,7037,00303,ZB3,,ZugeordneterMarktpartner,, + 621,Auftraggebender Marktpartner,SG10,CAV,,00304,,,,, + 622,Auftraggebender Marktpartner,SG10,CAV,7111,00304,Z88,,NB,, + 623,Auftraggebender Marktpartner,SG10,CAV,7111,,Z89,,LF,, + 624,Auftraggebender Marktpartner,SG10,CAV,1131,00304,,,MP-ID,, + 625,Produkt-Daten für Marktrolle relevant,SG10,,,,,,,, + 626,Produkt-Daten für Marktrolle relevant,SG10,CCI,,00305,,,,, + 627,Produkt-Daten für Marktrolle relevant,SG10,CCI,7037,00305,ZA7,,LF,, + 628,Daten der Messlokation,SG8,,,,,,,,[2284] Für jede Messlokations-ID im SG5 LOC+Z17 (Messlokation) DE3225 genau einmal anzugeben + 629,Daten der Messlokation,SG8,SEQ,,00306,,,,, + 630,Daten der Messlokation,SG8,SEQ,1229,00306,Z18,,Daten der Messlokation,, + 631,Referenz auf die ID der Messlokation,SG8,RFF,,00307,,,,, + 632,Referenz auf die ID der Messlokation,SG8,RFF,1153,00307,Z19,,Messlokation,, + 633,Referenz auf die ID der Messlokation,SG8,RFF,1154,00307,,,ID der Messlokation,,[951] Format: Zählpunktbezeichnung + 634,Abrechnung des Messstellenbetriebs über NNE für kME,SG8,RFF,,00309,,,,,"[235] Wenn das RFF+Z19 (Messlokation) aus dieser SG8 auf das gleiche SG5 LOC+Z17 (Messlokation), wie ein RFF+Z19 (Messlokation) aus einer SG8 SEQ+Z03 (Zähleinrichtungsdaten), in dem SG10 CCI+++E13 CAV+MME (Zählertyp: mME) nicht vorhanden ist, referenziert" + 635,Abrechnung des Messstellenbetriebs über NNE für kME,SG8,RFF,1153,00309,Z05,,Abrechnung desMessstellenbetriebs überNNE für kME,, + 636,Abrechnung des Messstellenbetriebs über NNE für kME,SG8,RFF,1154,00309,,,Abrechnung über NNE (Ja/Nein),, + 637,Zugeordnete Marktpartner,SG10,,,,,,,, + 638,Zugeordnete Marktpartner,SG10,CCI,,00310,,,,, + 639,Zugeordnete Marktpartner,SG10,CCI,7037,00310,ZB3,,ZugeordneterMarktpartner,, + 640,Messstellenbetreiber,SG10,CAV,,00311,,,,, + 641,Messstellenbetreiber,SG10,CAV,7111,00311,Z91,,MSB,, + 642,Messstellenbetreiber,SG10,CAV,1131,00311,,,MP-ID,, + 643,Messstellenbetreiber,SG10,CAV,7110,00311,Z19,,Auf vertraglicherGrundlage gegenüberAnschlussnutzer /Anschlussnehmer,, + 644,Messstellenbetreiber,SG10,CAV,7110,,Z20,,In der Ausübung derWeiterverpflichtungdurch den gMSB,, + 645,Messstellenbetreiber,SG10,CAV,7110,00311,Z39,,GrundzuständigerMessstellenbetreiber,, + 646,Messstellenbetreiber,SG10,CAV,7110,,Z40,,WettbewerblicherMessstellenbetreiber,, + 647,Messstellenbetreiber,SG10,CAV,7110,,Z41,,Auffangmessstellenbetreiber,, + 648,Grundzuständiger Messstellenbetreiber,SG10,CAV,,00312,,,,, + 649,Grundzuständiger Messstellenbetreiber,SG10,CAV,7111,00312,ZF0,,gMSB,, + 650,Grundzuständiger Messstellenbetreiber,SG10,CAV,1131,00312,,,MP-ID,, + 651,Spannungsebene der Messlokation,SG10,,,,,,,, + 652,Spannungsebene der Messlokation,SG10,CCI,,00314,,,,, + 653,Spannungsebene der Messlokation,SG10,CCI,7037,00314,E04,,Spannungsebene derMesslokation,, + 654,Spannungsebene der Messlokation,SG10,CAV,,00315,,,,, + 655,Spannungsebene der Messlokation,SG10,CAV,7111,00315,E03,,Höchstspannung,, + 656,Spannungsebene der Messlokation,SG10,CAV,7111,,E04,,Hochspannung,, + 657,Spannungsebene der Messlokation,SG10,CAV,7111,,E05,,Mittelspannung,, + 658,Spannungsebene der Messlokation,SG10,CAV,7111,,E06,,Niederspannung,, + 659,Zähleinrichtungsdaten,SG8,,,,,,,,[2286] Für jede SEQ+Z18 (Daten der Messlokation) mindestens einmal anzugeben + 660,Zähleinrichtungsdaten,SG8,SEQ,,00326,,,,, + 661,Zähleinrichtungsdaten,SG8,SEQ,1229,00326,Z03,,Zähleinrichtungsdaten,, + 662,Referenz auf die ID einer Messlokation,SG8,RFF,,00327,,,,, + 663,Referenz auf die ID einer Messlokation,SG8,RFF,1153,00327,Z19,,Messlokation,, + 664,Referenz auf die ID einer Messlokation,SG8,RFF,1154,00327,,,ID einer Messlokation,,[951] Format: Zählpunktbezeichnung + 665,Referenz auf das Smartmeter-Gateway,SG8,RFF,,00328,,,,,"[166] Wenn vorhanden + [215] Wenn in derselben SG8 SEQ+Z03 (Zähleinrichtungsdaten) SG10 CCI+++E13 CAV+MME (Zählertyp: mME) vorhanden" + 666,Referenz auf das Smartmeter-Gateway,SG8,RFF,1153,00328,Z14,,Smartmeter-Gateway,, + 667,Referenz auf das Smartmeter-Gateway,SG8,RFF,1154,00328,,,Identifikation / Nummer desSmartmeter-Gateways,, + 668,Zählertyp,SG10,,,,,,,, + 669,Zählertyp,SG10,CCI,,00329,,,,, + 670,Zählertyp,SG10,CCI,7037,00329,E13,,Zählertyp,, + 671,Zählertyp,SG10,CAV,,00330,,,,, + 672,Zählertyp,SG10,CAV,7111,00330,AHZ,,analoger Haushaltszähler(Drehstrom),, + 673,Zählertyp,SG10,CAV,7111,,WSZ,,analogerWechselstromzähler,, + 674,Zählertyp,SG10,CAV,7111,,LAZ,,Lastgangzähler,, + 675,Zählertyp,SG10,CAV,7111,,MAZ,,Maximumzähler,, + 676,Zählertyp,SG10,CAV,7111,,MME,,moderneMesseinrichtung nachMsbG,, + 677,Zählertyp,SG10,CAV,7111,,EHZ,,elektronischerHaushaltszähler,, + 678,Zählertyp,SG10,CAV,7111,,IVA,,Individuelle Abstimmung(Sonderausstattung),, + 679,Zählertyp,SG10,CAV,7110,00330,Z01,,EDL40,, + 680,Zählertyp,SG10,CAV,7110,,Z02,,EDL21,, + 681,Zählertyp,SG10,CAV,7110,,Z03,,sonstiger EHZ,, + 682,Zählertyp,SG10,CAV,7110,,Z04,,Standard,, + 683,Zählertyp,SG10,CAV,7110,,Z05,,MeDa-Zähler,,"[136] Wenn SG10 CCI+++E13 (Zählertyp) CAV+EHZ (elektronischer Haushaltszähler) vorhanden + [346] Wenn SG10 CCI+++E13 (Zählertyp) CAV+MME (mME) vorhanden" + 684,Identifikation / Nummer des Gerätes,SG10,CAV,,00331,,,,, + 685,Identifikation / Nummer des Gerätes,SG10,CAV,7111,00331,Z30,,Gerätenummer,, + 686,Identifikation / Nummer des Gerätes,SG10,CAV,7110,00331,,,Gerätenummer,, + 687,Registeranzahl,SG10,CAV,,00332,,,,,[139] Wenn SG10 CAV+IVA (Individuelle Abstimmung) nicht vorhanden + 688,Registeranzahl,SG10,CAV,7111,00332,ETZ,,Eintarif,, + 689,Registeranzahl,SG10,CAV,7111,,ZTZ,,Zweitarif,, + 690,Registeranzahl,SG10,CAV,7111,,NTZ,,Mehrtarif,, + 691,Energierichtung,SG10,CAV,,00333,,,,, + 692,Energierichtung,SG10,CAV,7111,00333,ERZ,,Einrichtungszähler,, + 693,Energierichtung,SG10,CAV,7111,,ZRZ,,Zweirichtungszähler,, + 694,Fernschaltung der Zähleinrichtung,SG10,CAV,,00334,,,,, + 695,Fernschaltung der Zähleinrichtung,SG10,CAV,7111,00334,Z58,,Fernschaltung derZähleinrichtung,, + 696,Fernschaltung der Zähleinrichtung,SG10,CAV,7110,00334,Z06,,vorhanden,, + 697,Fernschaltung der Zähleinrichtung,SG10,CAV,7110,,Z07,,nicht vorhanden,, + 698,Messwerterfassung an der Zähleinrichtung,SG10,,,,,,,,[316] Wenn in derselben SG8 das RFF+Z14 (Smartmeter-Gateway) nicht vorhanden + 699,Messwerterfassung an der Zähleinrichtung,SG10,CCI,,00337,,,,, + 700,Messwerterfassung an der Zähleinrichtung,SG10,CCI,7037,00337,E12,,Messwerterfassung ander Zähleinrichtung,, + 701,Messwerterfassung an der Zähleinrichtung,SG10,CAV,,00338,,,,, + 702,Messwerterfassung an der Zähleinrichtung,SG10,CAV,7111,00338,AMR,,fernauslesbare Zähler,, + 703,Messwerterfassung an der Zähleinrichtung,SG10,CAV,7111,,MMR,,manuell ausgeleseneZähler,, + 704,OBIS-Daten der Zähleinrichtung / Smartmeter-Gateway,SG8,,,,,,,,"[121] Wenn in dem SEQ+Z03 (Zähleinrichtungsdaten) das SG8 RFF+Z14 (Referenz auf das Smartmeter-Gateway) nicht vorhanden + [2287] Für jede SEQ+Z03 (Zähleinrichtungsdaten) mindestens einmal anzugeben + [2350] Für jedes SMGW das im SEQ+Z13 (Smartmeter-Gateway) SG10 CCI+++Z75" + 705,OBIS-Daten der Zähleinrichtung / Smartmeter-Gateway,SG8,SEQ,,00339,,,,, + 706,OBIS-Daten der Zähleinrichtung / Smartmeter-Gateway,SG8,SEQ,1229,00339,Z20,,OBIS-Daten derZähleinrichtung,, + 707,Referenz auf die Gerätenummer,SG8,RFF,,00340,,,,,[665] Hinweis: Wenn ein Zähler mit einem SMGW parametriert ist werden an dem Zähler keine OBIS-Kennzahlen angegeben Hier gibt es nur OBIS Kennzahlen vom SMGW + 708,Referenz auf die Gerätenummer,SG8,RFF,1153,00340,MG,,Gerätenummer desZählers,, + 709,Referenz auf die Gerätenummer,SG8,RFF,1153,,Z14,,Smartmeter-Gateway,,[441] Wenn im SG8+SEQ+Z03 (Zähleinrichtungsdaten) für die in diesem RFF DE1154 genannte Gerätenummer eines Zählers das RFF+Z14 (Referenz auf das Smartmeter-Gateway) nicht vorhanden ist + 710,Referenz auf die Gerätenummer,SG8,RFF,1154,00340,,,Gerätenummer,, + 711,Referenz auf die ID einer Messlokation,SG8,RFF,,00341,,,,, + 712,Referenz auf die ID einer Messlokation,SG8,RFF,1153,00341,Z19,,Messlokation,, + 713,Referenz auf die ID einer Messlokation,SG8,RFF,1154,00341,,,ID einer Messlokation,,[951] Format: Zählpunktbezeichnung + 714,Konfigurations-ID,SG8,RFF,,00343,,,,,"[40] Wenn SG4 STS+7++E02 (Transaktionsgrund: Einzug in Neuanlage) vorhanden + [78] Wenn SG4 STS+7++E02 (Transaktionsgrund: Einzug in Neuanlage)" + 715,Konfigurations-ID,SG8,RFF,1153,00343,AGK,,Anwendungsreferenznummer,, + 716,Konfigurations-ID,SG8,RFF,1154,00343,,,"Referenz, Identifikation",, + 717,OBIS-Kennzahl der Zähleinrichtung / Smartmeter-Gateway,SG8,PIA,,00344,,,,, + 718,OBIS-Kennzahl der Zähleinrichtung / Smartmeter-Gateway,SG8,PIA,4347,00344,5,,Produktidentifikation,, + 719,OBIS-Kennzahl der Zähleinrichtung / Smartmeter-Gateway,SG8,PIA,7140,00344,,,OBIS-Kennzahl derZähleinrichtung,,"[323] Es sind alle OBIS- Kennzahlen gem. EDI@Energy Codeliste der OBIS-Kennzahlen und Medien für den deutschen Energiemarkt Kap. 3. anzugeben, welche an der" + 720,OBIS-Kennzahl der Zähleinrichtung / Smartmeter-Gateway,SG8,PIA,7143,00344,SRW,,OBIS-Kennzahl,, + 721,Wertegranularität,SG10,,,,,,,,[256] Wenn in derselben SG8 SEQ+Z20 (OBIS- Daten der Zähleinrichtung / Smartmeter-Gateway) das PIA+5+1-b?:1.8.e / 1-b?:2.8.e vorhanden + 722,Wertegranularität,SG10,CCI,,00345,,,,, + 723,Wertegranularität,SG10,CCI,7037,00345,ZE4,,Wertegranularität,, + 724,Wertegranularität,SG10,CAV,,00346,,,,, + 725,Wertegranularität,SG10,CAV,7111,00346,ZD9,,Jährlich,, + 726,Wertegranularität,SG10,CAV,7111,,ZE8,,Halbjährlich,, + 727,Wertegranularität,SG10,CAV,7111,,ZE9,,Quartalsweise,, + 728,Wertegranularität,SG10,CAV,7111,,ZB7,,Monatlich,, + 729,Zugeordnete Zählzeitdefinition,SG10,,,,,,,,"[389] Wenn mehr als eine SG8 SEQ+Z20 (OBIS-Daten der Zähleinrichtung / Smartmeter-Gateway), die mit dem RFF+MG/ Z14 (Referenz auf die Gerätenummer) auf die gleiche Gerätenummer referenziert, mit einer OBIS-Kennzahl der Werteart ""Zählerstand"" im PIA+5 vorhanden + [391] Wenn in derselben SG8 SEQ+Z20 (OBIS Daten der Zähleinrichtung / Smartmeter-Gateway) eine OBIS-Kennzahl für Zählerstand im PIA+5 vorhanden und es sich lt. Codeliste OBIS um eine OBIS mit zugeordneter Zählzeit handelt (Tarif: e = 1 .. 62)" + 730,Zugeordnete Zählzeitdefinition,SG10,CCI,,00347,,,,, + 731,Zugeordnete Zählzeitdefinition,SG10,CCI,7059,00347,Z39,,Code derZählzeitdefinition,, + 732,Zugeordnete Zählzeitdefinition,SG10,CCI,7037,00347,,,Code der Zählzeitdefinition,, + 733,Zugeordnetes Zählzeitregister ,SG10,,,,,,,,[421] Wenn in dieser SG8 das SG10 CCI+Z39 (Zugeordnete Zählzeitdefinition) vorhanden ist + 734,Zugeordnetes Zählzeitregister ,SG10,CCI,,00348,,,,, + 735,Zugeordnetes Zählzeitregister ,SG10,CCI,7059,00348,Z38,,Code desZählzeitregisters,, + 736,Zugeordnetes Zählzeitregister ,SG10,CCI,7037,00348,,,Code des Zählzeitregisters,, + 737,Vor- und Nachkommastellen des Zählwerks,SG10,,,,,,,,[273] Wenn in derselben SG8 SEQ+Z20 (OBIS- Daten der Zähleinrichtung / Smartmeter-Gateway) das PIA+5+1-b?:1.8.e / 1-b?:2.8.e / 1-b?:3.8.e / 1-b?:4.8.e / 1-b?:5.8.e / 1-b?:6.8.e / 1-b?:7.8.e / 1-b?:8.8.e /  1-b?:1.8.63 vorhanden + 738,Vor- und Nachkommastellen des Zählwerks,SG10,CCI,,00349,,,,, + 739,Vor- und Nachkommastellen des Zählwerks,SG10,CCI,7059,00349,11,,Produkt,, + 740,Vor- und Nachkommastellen des Zählwerks,SG10,CCI,7037,00349,Z33,,Vor- undNachkommastellen desZählwerkes,, + 741,Vor- und Nachkommastellen des Zählwerks,SG10,CAV,,00350,,,,, + 742,Vor- und Nachkommastellen des Zählwerks,SG10,CAV,7110,00350,,,Angabe der Vorkommastelle,, + 743,Vor- und Nachkommastellen des Zählwerks,SG10,CAV,7110,00350,,,Angabe der Nachkommastelle,, + 744,Bezeichnung des Zählwerks auf dem Gerät,SG10,,,,,,,,[123] Wenn noch mindestens eine weitere SG8 SEQ+Z20 (OBIS- Daten der Zähleinrichtung Smartmeter-Gateway) mit dem SG8 RFF+MG (Gerätenummer des Zählers) auf die gleiche Identifikation/Nummer + 745,Bezeichnung des Zählwerks auf dem Gerät,SG10,CCI,,00351,,,,, + 746,Bezeichnung des Zählwerks auf dem Gerät,SG10,CCI,7037,00351,Z63,,Lokale Kennzeichnung zuKontrollzwecken,, + 747,Bezeichnung des Zählwerks auf dem Gerät,SG10,CCI,7036,00351,,,Bezeichnung des Zählwerks aufdem Gerät,, + 748,Wandlerdaten,SG8,,,,,,,,[130] Wenn an Messlokation vorhanden + 749,Wandlerdaten,SG8,SEQ,,00353,,,,, + 750,Wandlerdaten,SG8,SEQ,1229,00353,Z04,,Wandler-Daten,, + 751,Referenz auf die Gerätenummer,SG8,RFF,,00354,,,,, + 752,Referenz auf die Gerätenummer,SG8,RFF,1153,00354,MG,,Gerätenummer desZählers,, + 753,Referenz auf die Gerätenummer,SG8,RFF,1154,00354,,,Gerätenummer,, + 754,Wandler,SG10,,,,,,,, + 755,Wandler,SG10,CCI,,00355,,,,, + 756,Wandler,SG10,CCI,7037,00355,Z25,,Wandler,, + 757,Identifikation / Nummer des Gerätes,SG10,CAV,,00356,,,,,"[2317] Wenn in derselben SG8 SEQ+Z04 (Wandlerdaten) das SG10 CCI+++Z25 (Wandler) CAV+MIW/ MPW/MUW vorhanden, ist das Segment mindestens zweimal anzugeben + [2318] Wenn in derselben SG8 SEQ+Z04 (Wandlerdaten) das SG10 CCI+++Z25 (Wandler) CAV+MBW (Blockstromwandler)" + 758,Identifikation / Nummer des Gerätes,SG10,CAV,7111,00356,Z30,,Gerätenummer,, + 759,Identifikation / Nummer des Gerätes,SG10,CAV,7110,00356,,,Gerätenummer,, + 760,Wandlertyp und Faktor,SG10,CAV,,00357,,,,, + 761,Wandlertyp und Faktor,SG10,CAV,7111,00357,MIW,,Messwandlersatz Strom,, + 762,Wandlertyp und Faktor,SG10,CAV,7111,,MPW,,Kombimesswandlersatz(Strom und Spannung),, + 763,Wandlertyp und Faktor,SG10,CAV,7111,,MBW,,Blockstromwandler,, + 764,Wandlertyp und Faktor,SG10,CAV,7111,,MUW,,MesswandlersatzSpannung,, + 765,Wandlertyp und Faktor,SG10,CAV,7110,00357,,,Wandlerfaktor,,"[141] Wenn SG10 CAV+MIW/ MPW/ MBW vorhanden + [902] Format: Möglicher Wert: ≥ 0" + 766,Kommunikationseinrichtun gsdaten,SG8,,,,,,,,"[130] Wenn an Messlokation vorhanden + [2119] Je SG8 SEQ+Z13 (Smartmeter-Gateway) ist genau einmal die Segmentgruppe anzugeben" + 767,Kommunikationseinrichtun gsdaten,SG8,SEQ,,00358,,,,, + 768,Kommunikationseinrichtun gsdaten,SG8,SEQ,1229,00358,Z05,,Kommunikationseinrichtungsdaten,, + 769,Referenz auf die Gerätenummer,SG8,RFF,,00359,,,,, + 770,Referenz auf die Gerätenummer,SG8,RFF,1153,00359,MG,,Gerätenummer desZählers,, + 771,Referenz auf die Gerätenummer,SG8,RFF,1154,00359,,,Gerätenummer,, + 772,Kommunikationseinrichtun g,SG10,,,,,,,, + 773,Kommunikationseinrichtun g,SG10,CCI,,00360,,,,, + 774,Kommunikationseinrichtun g,SG10,CCI,7037,00360,Z26,,Kommunikationseinrichtung,, + 775,Identifikation / Nummer des Gerätes,SG10,CAV,,00361,,,,, + 776,Identifikation / Nummer des Gerätes,SG10,CAV,7111,00361,Z30,,Gerätenummer,, + 777,Identifikation / Nummer des Gerätes,SG10,CAV,7110,00361,,,Gerätenummer,, + 778,Kommunikationseinrichtun gstyp,SG10,CAV,,00362,,,,, + 779,Kommunikationseinrichtun gstyp,SG10,CAV,7111,00362,GSM,,GSM/GPRS/UMTS-Kom.-Einr.,, + 780,Kommunikationseinrichtun gstyp,SG10,CAV,7111,,ETH,,Ethernet-Kom.-Einricht.LAN/WLAN,, + 781,Kommunikationseinrichtun gstyp,SG10,CAV,7111,,PLC,,PLC-Kom.-Einrichtung,, + 782,Kommunikationseinrichtun gstyp,SG10,CAV,7111,,PST,,Festnetz-Kom.-Einricht.TAE,, + 783,Kommunikationseinrichtun gstyp,SG10,CAV,7111,,DSL,,DSL-Kom.Einr.,, + 784,Kommunikationseinrichtun gstyp,SG10,CAV,7111,,LTE,,LTE-Kom.-Einr.,, + 785,Daten der technischen Steuereinrichtung,SG8,,,,,,,,[130] Wenn an Messlokation vorhanden + 786,Daten der technischen Steuereinrichtung,SG8,SEQ,,00363,,,,, + 787,Daten der technischen Steuereinrichtung,SG8,SEQ,1229,00363,Z06,,Daten der technischenSteuereinrichtung,, + 788,Referenz auf die Gerätenummer,SG8,RFF,,00364,,,,, + 789,Referenz auf die Gerätenummer,SG8,RFF,1153,00364,MG,,Gerätenummer desZählers,, + 790,Referenz auf die Gerätenummer,SG8,RFF,1154,00364,,,Gerätenummer,, + 791,Technische Steuereinrichtung,SG10,,,,,,,, + 792,Technische Steuereinrichtung,SG10,CCI,,00365,,,,, + 793,Technische Steuereinrichtung,SG10,CCI,7037,00365,Z27,,TechnischeSteuereinrichtung,, + 794,Identifikation / Nummer des Gerätes,SG10,CAV,,00366,,,,, + 795,Identifikation / Nummer des Gerätes,SG10,CAV,7111,00366,Z30,,Gerätenummer,, + 796,Identifikation / Nummer des Gerätes,SG10,CAV,7110,00366,,,Gerätenummer,, + 797,Technische Steuereinrichtungstyp,SG10,CAV,,00367,,,,, + 798,Technische Steuereinrichtungstyp,SG10,CAV,7111,00367,RSU,,Rundsteuerempfänger,, + 799,Technische Steuereinrichtungstyp,SG10,CAV,7111,,TSU,,Tarifschaltuhr,, + 800,Smartmeter-Gateway,SG8,,,,,,,,[130] Wenn an Messlokation vorhanden + 801,Smartmeter-Gateway,SG8,SEQ,,00368,,,,, + 802,Smartmeter-Gateway,SG8,SEQ,1229,00368,Z13,,Smartmeter-Gateway,, + 803,Smartmeter-Gateway,SG10,,,,,,,, + 804,Smartmeter-Gateway,SG10,CCI,,00369,,,,, + 805,Smartmeter-Gateway,SG10,CCI,7037,00369,Z75,,Smartmeter-Gateway,, + 806,Identifikation / Nummer des Gerätes,SG10,CAV,,00370,,,,, + 807,Identifikation / Nummer des Gerätes,SG10,CAV,7111,00370,Z30,,Gerätenummer,, + 808,Identifikation / Nummer des Gerätes,SG10,CAV,7110,00370,,,Gerätenummer,,[952] Format: Gerätenummer nach DIN 43863-5 + 809,Daten der Steuerbox,SG8,,,,,,,,[133] Wenn an der übermittelten Marktlokation / Messlokation vorhanden + 810,Daten der Steuerbox,SG8,SEQ,,00371,,,,, + 811,Daten der Steuerbox,SG8,SEQ,1229,00371,Z14,,Steuerbox,, + 812,Referenz auf das Smartmeter-Gateway,SG8,RFF,,00372,,,,, + 813,Referenz auf das Smartmeter-Gateway,SG8,RFF,1153,00372,Z14,,Smartmeter-Gateway,, + 814,Referenz auf das Smartmeter-Gateway,SG8,RFF,1154,00372,,,Identifikation / Nummer desSmartmeter-Gateways,, + 815,Referenz auf die ID der Marktlokation,SG8,RFF,,00373,,,,, + 816,Referenz auf die ID der Marktlokation,SG8,RFF,1153,00373,Z18,,Marktlokation,, + 817,Referenz auf die ID der Marktlokation,SG8,RFF,1154,00373,,,ID einer Marktlokation,,[950] Format: Marktlokations-ID + 818,Steuerbox,SG10,,,,,,,, + 819,Steuerbox,SG10,CCI,,00374,,,,, + 820,Steuerbox,SG10,CCI,7037,00374,Z76,,Steuerbox,, + 821,Identifikation / Nummer des Gerätes,SG10,CAV,,00375,,,,, + 822,Identifikation / Nummer des Gerätes,SG10,CAV,7111,00375,Z30,,Gerätenummer,, + 823,Identifikation / Nummer des Gerätes,SG10,CAV,7110,00375,,,Gerätenummer,,[952] Format: Gerätenummer nach DIN 43863-5 + 824,Profildaten,SG8,,,,,,,,[119] Wenn in der SG8 SEQ+Z01 SG10 CCI+++ZA6 (Prognosegrundlage der + 825,Profildaten,SG8,SEQ,,00376,,,,, + 826,Profildaten,SG8,SEQ,1229,00376,Z21,,Profildaten,, + 827,Referenz auf die ID der Marktlokation,SG8,RFF,,00378,,,,, + 828,Referenz auf die ID der Marktlokation,SG8,RFF,1153,00378,Z18,,Marktlokation,, + 829,Referenz auf die ID der Marktlokation,SG8,RFF,1154,00378,,,ID einer Marktlokation,,[950] Format: Marktlokations-ID + 830,Normiertes Profil,SG10,,,,,,,, + 831,Normiertes Profil,SG10,CCI,,00380,,,,, + 832,Normiertes Profil,SG10,CCI,7059,00380,Z02,,Standardlastprofil,, + 833,Normiertes Profil,SG10,CCI,7037,00380,E01,,synthetisches Verfahren,, + 834,Normiertes Profil,SG10,CCI,7037,,Z10,,analytisches Verfahren,,[332] Wenn im SG8 SEQ+Z01 (Daten der Marktlokation) das SG10 CCI+6++ZA9 (Aggreg. verantw. ÜNB) nicht vorhanden + 835,Normiertes Profil,SG10,CAV,,00381,,,,, + 836,Normiertes Profil,SG10,CAV,7111,00381,,,Code des Normierten Profils,, + 837,Profilschardaten,SG8,,,,,,,,[89] Wenn im SG8 SEQ+Z01 (Daten der Marktlokation) das SG10 CCI+++ZA6 (Prognosegrundlage der Marktlokation: Prognose auf Basis von Profilen) CAV+E14 (TLP/TEP) vorhanden + 838,Profilschardaten,SG8,SEQ,,00387,,,,, + 839,Profilschardaten,SG8,SEQ,1229,00387,Z08,,Profilschardaten,, + 840,Referenz auf die ID der Marktlokation,SG8,RFF,,00389,,,,, + 841,Referenz auf die ID der Marktlokation,SG8,RFF,1153,00389,Z18,,Marktlokation,, + 842,Referenz auf die ID der Marktlokation,SG8,RFF,1154,00389,,,ID einer Marktlokation,,[950] Format: Marktlokations-ID + 843,Profilschar,SG10,,,,,,,, + 844,Profilschar,SG10,CCI,,00397,,,,, + 845,Profilschar,SG10,CCI,7037,00397,Z12,,Profilschar,, + 846,Profilschar,SG10,CAV,,00398,,,,, + 847,Profilschar,SG10,CAV,7111,00398,,,Code der Profilschar,, + 848,Normiertes Profil,SG10,,,,,,,, + 849,Normiertes Profil,SG10,CCI,,00399,,,,, + 850,Normiertes Profil,SG10,CCI,7059,00399,Z03,,tagesparameterabhängiges Lastprofil,, + 851,Normiertes Profil,SG10,CCI,7037,00399,E01,,synthetisches Verfahren,, + 852,Normiertes Profil,SG10,CCI,7037,,Z10,,analytisches Verfahren,, + 853,Normiertes Profil,SG10,CAV,,00400,,,,, + 854,Normiertes Profil,SG10,CAV,7111,00400,,,Code des Normierten Profils,, + 855,Klimazone / Temperaturmessstelle,SG10,,,,,,,, + 856,Klimazone / Temperaturmessstelle,SG10,CCI,,00403,,,,, + 857,Klimazone / Temperaturmessstelle,SG10,CCI,7059,00403,Z99,,Messstelle desTagesparameters(derzeit ist nur dieTemperatur ein erlaubterTagesparameter),, + 858,Klimazone / Temperaturmessstelle,SG10,CCI,7059,,ZA0,,Klimazone desTagesparameters(derzeit istTagesparameter),, + 859,Klimazone / Temperaturmessstelle,SG10,CCI,7037,00403,,,ID Klimazone /Temperaturmessstelle,, + 860,Klimazone / Temperaturmessstelle,SG10,CCI,1131,00403,,,Dienstanbieter,,[58] Wenn in diesem CCI das DE3055 mit dem Code 293 vorhanden + 861,Klimazone / Temperaturmessstelle,SG10,CCI,3055,00403,89,,Vergeben vom Händler(hier Netzbetreiber),, + 862,Klimazone / Temperaturmessstelle,SG10,CCI,3055,,293,,"DE, BDEW(Bundesverband derEnergie- undWasserwirtschaft e.V.)",, + 863,Daten des Kunden des Lieferanten,SG8,,,,,,,, + 864,Daten des Kunden des Lieferanten,SG8,SEQ,,00515,,,,, + 865,Daten des Kunden des Lieferanten,SG8,SEQ,1229,00515,Z75,,Daten des Kunden desLieferanten,, + 866,Grundlage zur Verringerung der Umlagen nach EnFG,SG10,,,,,,,, + 867,Grundlage zur Verringerung der Umlagen nach EnFG,SG10,CCI,,00516,,,,, + 868,Grundlage zur Verringerung der Umlagen nach EnFG,SG10,CCI,7059,00516,Z61,,Grundlage zurVerringerung der,, + 869,Grundlage zur Verringerung der Umlagen nach EnFG,SG10,CCI,7037,00516,ZF9,,Kunde erfüllt dieVoraussetzung nachEnFG,, + 870,Grundlage zur Verringerung der Umlagen nach EnFG,SG10,CCI,7037,,ZG0,,Kunde erfüllt nicht dieVoraussetzung nachEnFG,, + 871,Grundlage zur Verringerung der Umlagen nach EnFG,SG10,CCI,7037,,ZG1,,"Keine Angabe, daMarktlokation dieVoraussetzung zurVerringerung derUmlagen nach EnFGnicht erfüllt",, + 872,Grund der Privilegierung nach EnFG,SG10,CAV,,00517,,,,,[463] Wenn in derselben SG10 das CCI+Z61++ZF9 (Kunde erfüllt die Voraussetzung nach EnFG) vorhanden + 873,Grund der Privilegierung nach EnFG,SG10,CAV,7111,00517,ZU5,,§ 21 EnFG Stromspeicherund Verlustenergie,, + 874,Grund der Privilegierung nach EnFG,SG10,CAV,7111,,ZU6,,§ 22 EnFG elektrischangetriebeneWärmepumpen,, + 875,Grund der Privilegierung nach EnFG,SG10,CAV,7111,,ZU7,,§ 23 EnFGUmlageerhebung beiAnlagen zurVerstromung vonKuppelgasen,, + 876,Grund der Privilegierung nach EnFG,SG10,CAV,7111,,ZU8,,§ 24 EnFG Herstellungvon Grünen Wasserstoff,, + 877,Grund der Privilegierung nach EnFG,SG10,CAV,7111,,ZU9,,§§ 30 - 35 EnFGstromkostenintensiveUnternehmen,, + 878,Grund der Privilegierung nach EnFG,SG10,CAV,7111,,ZV0,,§ 36 EnFG Herstellungvon Wasserstoff instromkostenintensivenUnternehmen,, + 879,Grund der Privilegierung nach EnFG,SG10,CAV,7111,,ZV1,,§ 37 EnFGSchienenbahnen,, + 880,Grund der Privilegierung nach EnFG,SG10,CAV,7111,,ZV2,,§ 38 EnFG elektrischebetriebene Bussen imLinienverkehr,, + 881,Grund der Privilegierung nach EnFG,SG10,CAV,7111,,ZV3,,§ 39 EnFGLandstromanlagen,, + 882,Kunde des Lieferanten,SG12,,,,,,,,[572] Hinweis: Kundenname aus Anmeldung Lieferant neu + 883,Kunde des Lieferanten,SG12,NAD,,00518,,,,, + 884,Kunde des Lieferanten,SG12,NAD,3035,00518,Z09,,Kunde des LF,, + 885,Kunde des Lieferanten,SG12,NAD,3036,00518,,,Name,, + 886,Kunde des Lieferanten,SG12,NAD,3045,00518,Z01,,Struktur von,, + 887,Kundennummer beim Lieferanten,SG12,RFF,,00519,,,,,[147] Wenn in Anfrage vorhanden + 888,Kundennummer beim Lieferanten,SG12,RFF,1153,00519,AVC,,Kundennummer beimLieferanten,, + 889,Kundennummer beim Lieferanten,SG12,RFF,1154,00519,,,Kundennummer beim LF,, + 890,Kundennummer beim Altlieferant,SG12,RFF,,00520,,,,,"[165] Wenn bekannt + [333] Wenn IMD+Z36+Z13 (Identifikationslogik: Alle Identifikationsdaten) vorhanden" + 891,Kundennummer beim Altlieferant,SG12,RFF,1153,00520,Z01,,Kundennummer beimAltlieferanten,, + 892,Kundennummer beim Altlieferant,SG12,RFF,1154,00520,,,Kundennummer beim LFA,, + 893,Referenz auf die ID der Marktlokation,SG12,RFF,,00521,,,,, + 894,Referenz auf die ID der Marktlokation,SG12,RFF,1153,00521,Z18,,Marktlokation,, + 895,Referenz auf die ID der Marktlokation,SG12,RFF,1154,00521,,,ID der Marktlokation,,[950] Format: Marktlokations-ID + 896,Korrespondenzanschrift des Kunden des Lieferanten,SG12,,,,,,,,"[556] Hinweis: Wenn keine Korrespondenzanschrift des Endverbrauchers/ Kunden vorliegt, ist die Anschrift der Marktlokation zu übermitteln + [559] Hinweis: Die Korrespondenzanschrift des Endverbrauchers/ Kunden wird nicht zur Identifikation genutzt" + 897,Korrespondenzanschrift des Kunden des Lieferanten,SG12,NAD,,00522,,,,, + 898,Korrespondenzanschrift des Kunden des Lieferanten,SG12,NAD,3035,00522,Z04,,Korrespondenzanschriftdes Kunden des LF,, + 899,Korrespondenzanschrift des Kunden des Lieferanten,SG12,NAD,3036,00522,,,Name,, + 900,Korrespondenzanschrift des Kunden des Lieferanten,SG12,NAD,3045,00522,Z01,,Struktur vonPersonennamen,, + 901,Korrespondenzanschrift des Kunden des Lieferanten,SG12,NAD,3042,00522,,,Straße und Hausnummer oderPostfach,, + 902,Korrespondenzanschrift des Kunden des Lieferanten,SG12,NAD,3164,00522,,,Ort,, + 903,Korrespondenzanschrift des Kunden des Lieferanten,SG12,NAD,3251,00522,,,Postleitzahl,,"[166] Wenn vorhanden + [268] Wenn der Code im DE3207 in der ""EDI@Energy Codeliste der europäischen Ländercodes"" in der Spalte ""PLZ vorhanden"" ein ""X"" aufgeführt ist" + 904,Korrespondenzanschrift des Kunden des Lieferanten,SG12,NAD,3207,00522,,,"Ländername, Code",, + 905,Referenz auf die ID der Marktlokation,SG12,RFF,,00523,,,,, + 906,Referenz auf die ID der Marktlokation,SG12,RFF,1153,00523,Z18,,Marktlokation,, + 907,Referenz auf die ID der Marktlokation,SG12,RFF,1154,00523,,,ID der Marktlokation,,[950] Format: Marktlokations-ID + 908,Beteiligter Marktpartner MP-ID,SG12,,,,,,,Muss ([363]∧ [566]) ⊻([367] ∧[643]),"[363] Wenn SG4 STS+E01++A50 vorhanden + [367] Wenn SG4 STS+E01++A04 vorhanden + [566] Hinweis: Altlieferant + [643] Hinweis: Nachfolgender Netzbetreiber" + 909,Beteiligter Marktpartner MP-ID,SG12,NAD,,00533,,,,Muss, + 910,Beteiligter Marktpartner MP-ID,SG12,NAD,3035,00533,VY,,andere zugehörige Partei,X, + 911,Beteiligter Marktpartner MP-ID,SG12,NAD,3039,00533,,,MP-ID,X, + 912,Beteiligter Marktpartner MP-ID,SG12,NAD,3055,00533,9,,GS1,X, + 913,Beteiligter Marktpartner MP-ID,SG12,NAD,3055,,293,,"DE, BDEW(Bundesverband derEnergie- undWasserwirtschaft e.V.)",X, + 914,Referenz auf die ID einer Marktlokation / Tranche,SG12,RFF,,00534,,,,Muss, + 915,Referenz auf die ID einer Marktlokation / Tranche,SG12,RFF,1153,00534,Z18,,Marktlokation,X, + 916,Referenz auf die ID einer Marktlokation / Tranche,SG12,RFF,1154,00534,,,ID einer Marktlokation / Tranche,X [950],[950] Format: Marktlokations-ID + 917,Marktlokationsanschrift,SG12,,,,,,,,"[165] Wenn bekannt + [333] Wenn IMD+Z36+Z13 (Identifikationslogik: Alle Identifikationsdaten) vorhanden" + 918,Marktlokationsanschrift,SG12,NAD,,00535,,,,, + 919,Marktlokationsanschrift,SG12,NAD,3035,00535,DP,,Lieferanschrift,, + 920,Marktlokationsanschrift,SG12,NAD,3124,00535,,,Zusatzinformation zurIdentifizierung,, + 921,Marktlokationsanschrift,SG12,NAD,3042,00535,,,Straße und Hausnummer oderPostfach,,"[165] Wenn bekannt + [166] Wenn vorhanden + [212] Wenn im selben SG12 NAD DE3124 nicht vorhanden" + 922,Marktlokationsanschrift,SG12,NAD,3164,00535,,,Ort,, + 923,Marktlokationsanschrift,SG12,NAD,3251,00535,,,Postleitzahl,, + 924,Marktlokationsanschrift,SG12,NAD,3207,00535,,,"Ländername, Code",, + 925,Name und Adresse für die Ablesekarte,SG12,,,,,,,,"[234] Wenn SG10 CCI+++Z83 (Messtechnische Einordnung der Marktlokation) CAV+Z53 (kME/ mME) vorhanden + [560] Hinweis: Die Angabe Name und Adresse für die Ablesekarte wird nicht zur Identifikation genutzt" + 926,Name und Adresse für die Ablesekarte,SG12,NAD,,00538,,,,, + 927,Name und Adresse für die Ablesekarte,SG12,NAD,3035,00538,Z05,,Name und Adresse fürdie Ablesekarte,, + 928,Name und Adresse für die Ablesekarte,SG12,NAD,3036,00538,,,Name,, + 929,Name und Adresse für die Ablesekarte,SG12,NAD,3045,00538,Z01,,Struktur vonPersonennamen,, + 930,Name und Adresse für die Ablesekarte,SG12,NAD,3045,,Z02,,Struktur derFirmenbezeichnung,, + 931,Name und Adresse für die Ablesekarte,SG12,NAD,3042,00538,,,Straße und Hausnummer oderPostfach,, + 932,Name und Adresse für die Ablesekarte,SG12,NAD,3164,00538,,,Ort,, + 933,Name und Adresse für die Ablesekarte,SG12,NAD,3251,00538,,,Postleitzahl,,"[166] Wenn vorhanden + [268] Wenn der Code im DE3207 in der ""EDI@Energy Codeliste der europäischen Ländercodes"" in der" + 934,Name und Adresse für die Ablesekarte,SG12,NAD,3207,00538,,,"Ländername, Code",, + 935,Referenz auf die ID einer Messlokation,SG12,RFF,,00539,,,,, + 936,Referenz auf die ID einer Messlokation,SG12,RFF,1153,00539,Z19,,Messlokation,, + 937,Referenz auf die ID einer Messlokation,SG12,RFF,1154,00539,,,ID einer Messlokation,,[951] Format: Zählpunktbezeichnung + 938,Nachrichten-Endesegment,,UNT,,00540,,,,Muss, + 939,Nachrichten-Endesegment,,UNT,0074,00540,,,Anzahl der Segmente in einerNachricht,X, + 940,Nachrichten-Endesegment,,UNT,0062,00540,,,Nachrichten-Referenznummer,X, + + ''' +# --- +# name: TestCli.test_kohlrahbi_cli_with_valid_arguments[55009] + ''' + ,Segmentname,Segmentgruppe,Segment,Datenelement,Segment ID,Code,Qualifier,Beschreibung,Bedingungsausdruck,Bedingung + 0,Nachrichten-Kopfsegment,,UNH,,00003,,,,Muss, + 1,Nachrichten-Kopfsegment,,UNH,0062,00003,,,Nachrichten-Referenznummer,X, + 2,Nachrichten-Kopfsegment,,UNH,0065,00003,UTILMD,,Netzanschluss-Stammdaten,X, + 3,Nachrichten-Kopfsegment,,UNH,0052,00003,D,,Entwurfs-Version,X, + 4,Nachrichten-Kopfsegment,,UNH,0054,00003,11A,,Ausgabe 2011 - A,X, + 5,Nachrichten-Kopfsegment,,UNH,0051,00003,UN,,UN/CEFACT,X, + 6,Nachrichten-Kopfsegment,,UNH,0057,00003,Versionsnummer derzugrundeliegendenBDEW-Nachrichtenbeschreibung,,S1.1a,X, + 7,Beginn der Nachricht,,BGM,,00004,,,,Muss, + 8,Beginn der Nachricht,,BGM,1001,00004,E02,,Abmeldungen,X, + 9,Beginn der Nachricht,,BGM,1004,00004,,,Dokumentennummer,X, + 10,Nachrichtendatum,,DTM,,00005,,,,Muss, + 11,Nachrichtendatum,,DTM,2005,00005,137,,Dokumenten-/Nachrichtendatum/-zeit,X, + 12,Nachrichtendatum,,DTM,2380,00005,,,"Datum oder Uhrzeit oderZeitspanne, Wert",X [931][494],"[494] Das hier genannte Datum muss der Zeitpunkt sein, zu dem das Dokument erstellt wurde, oder ein Zeitpunkt, der davor liegt + [931] Format: ZZZ = +00" + 13,Nachrichtendatum,,DTM,2379,00005,303,,CCYYMMDDHHMMZZZ,X, + 14,MP-ID Absender,SG2,,,,,,,Muss, + 15,MP-ID Absender,SG2,NAD,,00008,,,,Muss, + 16,MP-ID Absender,SG2,NAD,3035,00008,MS,,Dokumenten-/Nachrichtenausstellerbzw. -absender,X, + 17,MP-ID Absender,SG2,NAD,3039,00008,,,MP-ID,X, + 18,MP-ID Absender,SG2,NAD,3055,00008,9,,GS1,X, + 19,MP-ID Absender,SG2,NAD,3055,,293,,"DE, BDEW(Bundesverband derEnergie- undWasserwirtschaft e.V.)",X, + 20,Ansprechpartner,SG3,,,,,,,Kann, + 21,Ansprechpartner,SG3,CTA,,00009,,,,Muss, + 22,Ansprechpartner,SG3,CTA,3139,00009,IC,,Informationskontakt,X, + 23,Ansprechpartner,SG3,CTA,3412,00009,,,Name vom Ansprechpartner,X, + 24,Kommunikationsverbindung,SG3,COM,,00010,,,,Muss, + 25,Kommunikationsverbindung,SG3,COM,3148,00010,,,Nummer / Adresse,X (([939][321]) ∨([940][322])) ∧[514],"[321] Wenn im DE3155 in demselben COM der Code EM vorhanden ist + [322] Wenn im DE3155 in demselben COM der Code TE / FX / AJ / AL vorhanden ist + [514] Hinweis: Es darf nur eine Information im DE3148 übermittelt werden + [939] Format: Die Zeichenkette muss die Zeichen @ und . enthalten + [940] Format: Die Zeichenkette muss mit dem Zeichen + beginnen und danach dürfen nur noch Ziffern folgen" + 26,Kommunikationsverbindung,SG3,COM,3155,00010,EM,,Elektronische Post,X [1P0..1], + 27,Kommunikationsverbindung,SG3,COM,3155,,FX,,Telefax,X [1P0..1], + 28,Kommunikationsverbindung,SG3,COM,3155,,TE,,Telefon,X [1P0..1], + 29,Kommunikationsverbindung,SG3,COM,3155,,AJ,,weiteres Telefon,X [1P0..1], + 30,Kommunikationsverbindung,SG3,COM,3155,,AL,,Handy,X [1P0..1], + 31,MP-ID Empfänger,SG2,,,,,,,Muss, + 32,MP-ID Empfänger,SG2,NAD,,00011,,,,Muss, + 33,MP-ID Empfänger,SG2,NAD,3035,00011,MR,,Nachrichtenempfänger,X, + 34,MP-ID Empfänger,SG2,NAD,3039,00011,,,MP-ID,X, + 35,MP-ID Empfänger,SG2,NAD,3055,00011,9,,GS1,X, + 36,MP-ID Empfänger,SG2,NAD,3055,,293,,"DE, BDEW(Bundesverband derEnergie- undWasserwirtschaft e.V.)",X, + 37,Vorgang,SG4,,,,,,,Muss, + 38,Vorgang,SG4,IDE,,00020,,,,Muss, + 39,Vorgang,SG4,IDE,7495,00020,24,,Transaktion,X, + 40,Vorgang,SG4,IDE,7402,00020,,,Vorgangsnummer,X, + 41,Ende zum,SG4,DTM,,00025,,,,, + 42,Ende zum,SG4,DTM,2005,00025,93,,Datum Vertragsende,, + 43,Ende zum,SG4,DTM,2380,00025,,,"Datum oder Uhrzeit oderZeitspanne, Wert",, + 44,Ende zum,SG4,DTM,2379,00025,303,,CCYYMMDDHHMMZZZ,, + 45,Bilanzierungsende,SG4,DTM,,00030,,,,,"[29] Wenn eine Bilanzierung stattfindet + [33] Wenn in Abmeldung ein Bilanzierungsende vorhanden" + 46,Bilanzierungsende,SG4,DTM,2005,00030,159,,Bilanzierungsende,, + 47,Bilanzierungsende,SG4,DTM,2380,00030,,,"Datum oder Uhrzeit oderZeitspanne, Wert",, + 48,Bilanzierungsende,SG4,DTM,2379,00030,303,,CCYYMMDDHHMMZZZ,, + 49,Transaktionsgrund,SG4,STS,,00037,,,,Muss [2061],[2061] Segment bzw. Segmentgruppe ist genau einmal je SG4 IDE (Vorgang) anzugeben + 50,Transaktionsgrund,SG4,STS,9015,00037,7,,Transaktionsgrund,X, + 51,Transaktionsgrund,SG4,STS,9013,00037,Z33,,Auszug wegen Stilllegung,X, + 52,Transaktionsgrund,SG4,STS,9013,,ZQ7,,Abmeldung wg. fehl.Zuordnungsermächtigung,X, + 53,Transaktionsgrund,SG4,STS,9013,,ZT0,,Abmeldung wegen fehl.Zuordnungsermächtigung aufgrund ÄnderungZRT,X, + 54,Status der Antwort,SG4,STS,,00039,,,,Muss [249],[249] Innerhalb eines SG4 IDE müssen alle DE1131 der SG4 STS+E01 den identischen Wert enthalten + 55,Status der Antwort,SG4,STS,9015,00039,E01,,Status der Antwort,X, + 56,Status der Antwort,SG4,STS,9013,00039,,,Code des Prüfschritts,X [359],"[359] Es sind nur Antwortcodes aus dem Cluster Ablehnung erlaubt + [360] Es sind nur Antwortcodes aus dem Cluster Zustimmung erlaubt" + 57,Status der Antwort,SG4,STS,1131,00039,E_0502,,EBD Nr. E_0502,X, + 58,Bemerkung (Feld für allgemeine Hinweise),SG4,FTX,,00043,,,,Muss [48] ⊻[437]Kann,[48] Wenn in dieser SG4 das STS+E01++E14/ A99 (Status der Antwort: Ablehnung Sonstiges) vorhanden + 59,Bemerkung (Feld für allgemeine Hinweise),SG4,FTX,4451,00043,ACB,,ZusätzlicheInformationen (fürallgemeine Hinweise),X, + 60,Bemerkung (Feld für allgemeine Hinweise),SG4,FTX,4440,00043,,,Text für allgemeine Information,X, + 61,Marktlokation,SG5,,,,,,,Muss [2061],[2061] Segment bzw. Segmentgruppe ist genau einmal je SG4 IDE (Vorgang) anzugeben + 62,Marktlokation,SG5,LOC,,00051,,,,Muss, + 63,Marktlokation,SG5,LOC,3227,00051,Z16,,Marktlokation,X, + 64,Marktlokation,SG5,LOC,3225,00051,,,ID der Marktlokation,X [950],[950] Format: Marktlokations-ID + 65,Prüfidentifikator,SG6,,,,,,,Muss, + 66,Prüfidentifikator,SG6,RFF,,00057,,,,Muss, + 67,Prüfidentifikator,SG6,RFF,1153,00057,Z13,,Prüfidentifikator,X, + 68,Prüfidentifikator,SG6,RFF,1154,00057,55007,,GPKE / Abmeldung NNvom NB,, + 69,Prüfidentifikator,SG6,RFF,1154,,55008,,GPKE / BestätigungAbmeldung vom NB,, + 70,Prüfidentifikator,SG6,RFF,1154,,55009,,GPKE / AblehnungAbmeldung vom NB,X, + 71,Referenz Vorgangsnummer (aus Anfragenachricht),SG6,,,,,,,Muss, + 72,Referenz Vorgangsnummer (aus Anfragenachricht),SG6,RFF,,00058,,,,Muss, + 73,Referenz Vorgangsnummer (aus Anfragenachricht),SG6,RFF,1153,00058,TN,,Transaktions-Referenznummer,X, + 74,Referenz Vorgangsnummer (aus Anfragenachricht),SG6,RFF,1154,00058,,,Vorgangsnummer,X, + 75,Daten der Marktlokation,SG8,,,,,,,Muss [2061],[2061] Segment bzw. Segmentgruppe ist genau einmal je SG4 IDE (Vorgang) anzugeben + 76,Daten der Marktlokation,SG8,SEQ,,00103,,,,Muss, + 77,Daten der Marktlokation,SG8,SEQ,1229,00103,Z01,,Daten der Marktlokation,X, + 78,Referenz auf die ID der Marktlokation,SG8,RFF,,00104,,,,Muss, + 79,Referenz auf die ID der Marktlokation,SG8,RFF,1153,00104,Z18,,Marktlokation,X, + 80,Referenz auf die ID der Marktlokation,SG8,RFF,1154,00104,,,ID der Marktlokation,X [950],[950] Format: Marktlokations-ID + 81,Lieferrichtung,SG10,,,,,,,Muss, + 82,Lieferrichtung,SG10,CCI,,00110,,,,Muss, + 83,Lieferrichtung,SG10,CCI,7059,00110,Z30,,Lieferrichtung,X, + 84,Lieferrichtung,SG10,CCI,7037,00110,Z07,,Verbrauch,X, + 85,Nachrichten-Endesegment,,UNT,,00540,,,,Muss, + 86,Nachrichten-Endesegment,,UNT,0074,00540,,,Anzahl der Segmente in einerNachricht,X, + 87,Nachrichten-Endesegment,,UNT,0062,00540,,,Nachrichten-Referenznummer,X, + + ''' +# --- +# name: TestCli.test_kohlrahbi_cli_with_valid_arguments[55014] + ''' + ,Segmentname,Segmentgruppe,Segment,Datenelement,Segment ID,Code,Qualifier,Beschreibung,Bedingungsausdruck,Bedingung + 0,Nachrichten-Kopfsegment,,UNH,,00003,,,,Muss, + 1,Nachrichten-Kopfsegment,,UNH,0062,00003,,,Nachrichten-Referenznummer,X, + 2,Nachrichten-Kopfsegment,,UNH,0065,00003,UTILMD,,Netzanschluss-Stammdaten,X, + 3,Nachrichten-Kopfsegment,,UNH,0052,00003,D,,Entwurfs-Version,X, + 4,Nachrichten-Kopfsegment,,UNH,0054,00003,11A,,Ausgabe 2011 - A,X, + 5,Nachrichten-Kopfsegment,,UNH,0051,00003,UN,,UN/CEFACT,X, + 6,Nachrichten-Kopfsegment,,UNH,0057,00003,Versionsnummer derzugrundeliegendenBDEW-Nachrichtenbeschreibung,,S1.1a,X, + 7,Beginn der Nachricht,,BGM,,00004,,,,Muss, + 8,Beginn der Nachricht,,BGM,1001,00004,E01,,Anmeldungen,X, + 9,Beginn der Nachricht,,BGM,1004,00004,,,Dokumentennummer,X, + 10,Nachrichtendatum,,DTM,,00005,,,,Muss, + 11,Nachrichtendatum,,DTM,2005,00005,137,,Dokumenten-/Nachrichtendatum/-zeit,X, + 12,Nachrichtendatum,,DTM,2380,00005,,,"Datum oder Uhrzeit oderZeitspanne, Wert",X [931][494],"[494] Das hier genannte Datum muss der Zeitpunkt sein, zu dem das Dokument erstellt wurde, oder ein Zeitpunkt, der davor liegt + [931] Format: ZZZ = +00" + 13,Nachrichtendatum,,DTM,2379,00005,303,,CCYYMMDDHHMMZZZ,X, + 14,MP-ID Absender,SG2,,,,,,,Muss, + 15,MP-ID Absender,SG2,NAD,,00008,,,,Muss, + 16,MP-ID Absender,SG2,NAD,3035,00008,MS,,Dokumenten-/Nachrichtenausstellerbzw. -absender,X, + 17,MP-ID Absender,SG2,NAD,3039,00008,,,MP-ID,X, + 18,MP-ID Absender,SG2,NAD,3055,00008,9,,GS1,X, + 19,MP-ID Absender,SG2,NAD,3055,,293,,"DE, BDEW(Bundesverband derEnergie- undWasserwirtschaft e.V.)",X, + 20,Ansprechpartner,SG3,,,,,,,Kann, + 21,Ansprechpartner,SG3,CTA,,00009,,,,Muss, + 22,Ansprechpartner,SG3,CTA,3139,00009,IC,,Informationskontakt,X, + 23,Ansprechpartner,SG3,CTA,3412,00009,,,Name vom Ansprechpartner,X, + 24,Kommunikationsverbindung,SG3,COM,,00010,,,,Muss, + 25,Kommunikationsverbindung,SG3,COM,3148,00010,,,Nummer / Adresse,X (([939][321]) ∨([940][322])) ∧[514],"[321] Wenn im DE3155 in demselben COM der Code EM vorhanden ist + [322] Wenn im DE3155 in demselben COM der Code TE / FX / AJ / AL vorhanden ist + [514] Hinweis: Es darf nur eine Information im DE3148 übermittelt werden + [939] Format: Die Zeichenkette muss die Zeichen @ und . enthalten + [940] Format: Die Zeichenkette muss mit dem Zeichen + beginnen und danach dürfen nur noch Ziffern folgen" + 26,Kommunikationsverbindung,SG3,COM,3155,00010,EM,,Elektronische Post,X [1P0..1], + 27,Kommunikationsverbindung,SG3,COM,3155,,FX,,Telefax,X [1P0..1], + 28,Kommunikationsverbindung,SG3,COM,3155,,TE,,Telefon,X [1P0..1], + 29,Kommunikationsverbindung,SG3,COM,3155,,AJ,,weiteres Telefon,X [1P0..1], + 30,Kommunikationsverbindung,SG3,COM,3155,,AL,,Handy,X [1P0..1], + 31,MP-ID Empfänger,SG2,,,,,,,Muss, + 32,MP-ID Empfänger,SG2,NAD,,00011,,,,Muss, + 33,MP-ID Empfänger,SG2,NAD,3035,00011,MR,,Nachrichtenempfänger,X, + 34,MP-ID Empfänger,SG2,NAD,3039,00011,,,MP-ID,X, + 35,MP-ID Empfänger,SG2,NAD,3055,00011,9,,GS1,X, + 36,MP-ID Empfänger,SG2,NAD,3055,,293,,"DE, BDEW(Bundesverband derEnergie- undWasserwirtschaft e.V.)",X, + 37,Vorgang,SG4,,,,,,,Muss, + 38,Vorgang,SG4,IDE,,00020,,,,Muss, + 39,Vorgang,SG4,IDE,7495,00020,24,,Transaktion,X, + 40,Vorgang,SG4,IDE,7402,00020,,,Vorgangsnummer,X, + 41,Beginn zum,SG4,DTM,,00024,,,,Muss, + 42,Beginn zum,SG4,DTM,2005,00024,92,,Datum Vertragsbeginn,X, + 43,Beginn zum,SG4,DTM,2380,00024,,,"Datum oder Uhrzeit oderZeitspanne, Wert",X [UB1], + 44,Beginn zum,SG4,DTM,2379,00024,303,,CCYYMMDDHHMMZZZ,X, + 45,Ende zum,SG4,DTM,,00025,,,,Muss [10],[10] Wenn SG4 STS+Z17 (Transaktionsgrund für befristete Anmeldung) vorhanden + 46,Ende zum,SG4,DTM,2005,00025,93,,Datum Vertragsende,X, + 47,Ende zum,SG4,DTM,2380,00025,,,"Datum oder Uhrzeit oderZeitspanne, Wert",X [UB1], + 48,Ende zum,SG4,DTM,2379,00025,303,,CCYYMMDDHHMMZZZ,X, + 49,Bilanzierungsbeginn,SG4,DTM,,00029,,,,Muss [18]Soll [28] ∧[29],"[18] Wenn SG4 DTM+93 (Ende zum) nicht vorhanden + [28] Wenn SG4 DTM+93 (Ende zum) vorhanden + [29] Wenn eine Bilanzierung stattfindet" + 50,Bilanzierungsbeginn,SG4,DTM,2005,00029,158,,Bilanzierungsbeginn,X, + 51,Bilanzierungsbeginn,SG4,DTM,2380,00029,,,"Datum oder Uhrzeit oderZeitspanne, Wert",X [UB1], + 52,Bilanzierungsbeginn,SG4,DTM,2379,00029,303,,CCYYMMDDHHMMZZZ,X, + 53,Bilanzierungsende,SG4,DTM,,00030,,,,Muss [28] ∧[64],"[28] Wenn SG4 DTM+93 (Ende zum) vorhanden + [64] Wenn SG4 DTM+158 (Bilanzierungsbeginn) vorhanden" + 54,Bilanzierungsende,SG4,DTM,2005,00030,159,,Bilanzierungsende,X, + 55,Bilanzierungsende,SG4,DTM,2380,00030,,,"Datum oder Uhrzeit oderZeitspanne, Wert",X [UB1], + 56,Bilanzierungsende,SG4,DTM,2379,00030,303,,CCYYMMDDHHMMZZZ,X, + 57,Transaktionsgrund,SG4,STS,,00037,,,,Muss [2061],[2061] Segment bzw. Segmentgruppe ist genau einmal je SG4 IDE (Vorgang) anzugeben + 58,Transaktionsgrund,SG4,STS,9015,00037,7,,Transaktionsgrund,X, + 59,Transaktionsgrund,SG4,STS,9013,00037,E06,,Ersatzbelieferung,X [580], + 60,Transaktionsgrund,SG4,STS,9013,,Z02,,KündigungLieferantenrahmenvertrag,X, + 61,Transaktionsgrund,SG4,STS,9013,,Z36,,EoG aus Ein-/Auszug(Umzug),X, + 62,Transaktionsgrund,SG4,STS,9013,,Z37,,EoG wegen Einzug inNeuanlage,X,"[580] Hinweis: Ersatzbelieferung gibt es nur bei - Marktlokationen in der Niederspannung, die kein Haushaltskunde gem. EnWG sind und die nicht mehr der" + 63,Transaktionsgrundergänzun g für Lieferende bei befristeter Anmeldung,SG4,STS,,00038,,,,Soll [37],[37] Wenn Anmeldung/ Änderung befristet + 64,Transaktionsgrundergänzun g für Lieferende bei befristeter Anmeldung,SG4,STS,9015,00038,Z17,,Transaktionsgrundergänzung für befristeteAnmeldung,X, + 65,Transaktionsgrundergänzun g für Lieferende bei befristeter Anmeldung,SG4,STS,9013,00038,E01,,Ein-/Auszug (Umzug),X, + 66,Transaktionsgrundergänzun g für Lieferende bei befristeter Anmeldung,SG4,STS,9013,,E03,,Wechsel,X, + 67,Status der Antwort,SG4,STS,,00039,,,,Muss [249],[249] Innerhalb eines SG4 IDE müssen alle DE1131 der SG4 STS+E01 den identischen Wert enthalten + 68,Status der Antwort,SG4,STS,9015,00039,E01,,Status der Antwort,X, + 69,Status der Antwort,SG4,STS,9013,00039,,,Code des Prüfschritts,X, + 70,Status der Antwort,SG4,STS,1131,00039,Codeliste Strom Nr.S_0003Codeliste Strom Nr.S_0004,,S_0003S_0004,X, + 71,Bemerkung (Feld für allgemeine Hinweise),SG4,FTX,,00043,,,,Kann,[48] Wenn in dieser SG4 das STS+E01++E14/ A99 (Status der Antwort: Ablehnung Sonstiges) vorhanden + 72,Bemerkung (Feld für allgemeine Hinweise),SG4,FTX,4451,00043,ACB,,ZusätzlicheInformationen (fürallgemeine Hinweise),X, + 73,Bemerkung (Feld für allgemeine Hinweise),SG4,FTX,4440,00043,,,Text für allgemeine Information,X, + 74,Netzlokation,SG5,,,,,,,Soll [46] ∧[688],"[46] Wenn ID für Objekt vergeben wurde + [688] Hinweis: Es sind alle ID der Netzlokationen, welche der im LOC+Z16 angegebenen Marktlokation vorgelagert sind anzugeben" + 75,Netzlokation,SG5,LOC,,00050,,,,Muss, + 76,Netzlokation,SG5,LOC,3227,00050,Z18,,Netzlokation,X, + 77,Netzlokation,SG5,LOC,3225,00050,,,ID der Netzlokation,X [960],[960] Format: Netzlokations-ID + 78,Marktlokation,SG5,,,,,,,Muss [2061],[2061] Segment bzw. Segmentgruppe ist genau einmal je SG4 IDE (Vorgang) anzugeben + 79,Marktlokation,SG5,LOC,,00051,,,,Muss, + 80,Marktlokation,SG5,LOC,3227,00051,Z16,,Marktlokation,X, + 81,Marktlokation,SG5,LOC,3225,00051,,,ID der Marktlokation,X [950],[950] Format: Marktlokations-ID + 82,Technische Ressource,SG5,,,,,,,Soll [46] ∧[689],"[46] Wenn ID für Objekt vergeben wurde + [689] Hinweis: Es sind alle ID der Technischen Ressourcen, welche der im LOC+Z16 angegebenen Marktlokation zugehören anzugeben + [694] Hinweis: Wenn in einer Marktlokation eine ID für eine Technischen Ressource vergeben wird, müssen für alle ggf. weitere Technische Ressourcen in der Marktlokation ID vergeben werden. Hintergrund: MSB und LF benötigen einen vollständigen Überblick auf die Art und Nutzung der Technischen Ressourcen in einer Marktlokation für die Plausibilisierung," + 83,Technische Ressource,SG5,LOC,,00052,,,,Muss, + 84,Technische Ressource,SG5,LOC,3227,00052,Z20,,Technische Ressource,X, + 85,Technische Ressource,SG5,LOC,3225,00052,,,ID der Technischen Ressource,X [922],[922] Format: TR-ID + 86,Steuerbare Ressource,SG5,,,,,,,Soll [46] ∧[690],"[46] Wenn ID für Objekt vergeben wurde + [690] Hinweis: Es sind alle ID der Steuerbaren Ressourcen, welche der im LOC+Z20 angegebenen Technischen Ressourcen zugeordnet sind anzugeben" + 87,Steuerbare Ressource,SG5,LOC,,00053,,,,Muss, + 88,Steuerbare Ressource,SG5,LOC,3227,00053,Z19,,Steuerbare Ressource,X, + 89,Steuerbare Ressource,SG5,LOC,3225,00053,,,ID der Steuerbaren Ressource,X [961],[961] Format: SR-ID + 90,Messlokation,SG5,,,,,,,Soll [166] ∧[527],"[166] Wenn vorhanden + [527] Hinweis: Es sind alle Identifikatoren der Messlokationen anzugeben" + 91,Messlokation,SG5,LOC,,00055,,,,Muss, + 92,Messlokation,SG5,LOC,3227,00055,Z17,,Messlokation,X, + 93,Messlokation,SG5,LOC,3225,00055,,,ID der Messlokation,X [951],[951] Format: Zählpunktbezeichnung + 94,Prüfidentifikator,SG6,,,,,,,Muss, + 95,Prüfidentifikator,SG6,RFF,,00057,,,,Muss, + 96,Prüfidentifikator,SG6,RFF,1153,00057,Z13,,Prüfidentifikator,X, + 97,Prüfidentifikator,SG6,RFF,1154,00057,55013,,GPKE / Anmeldung EoG,, + 98,Prüfidentifikator,SG6,RFF,1154,,55014,,GPKE / Bestätigung EoGAnmeldung,X, + 99,Prüfidentifikator,SG6,RFF,1154,,55015,,GPKE / Ablehnung EoGAnmeldung,, + 100,Referenz Vorgangsnummer (aus Anfragenachricht),SG6,,,,,,,Muss, + 101,Referenz Vorgangsnummer (aus Anfragenachricht),SG6,RFF,,00058,,,,Muss, + 102,Referenz Vorgangsnummer (aus Anfragenachricht),SG6,RFF,1153,00058,TN,,Transaktions-Referenznummer,X, + 103,Referenz Vorgangsnummer (aus Anfragenachricht),SG6,RFF,1154,00058,,,Vorgangsnummer,X, + 104,Referenz auf die ID der Marktlokation für Termine der Marktlokation,SG6,,,,,,,Muss, + 105,Referenz auf die ID der Marktlokation für Termine der Marktlokation,SG6,RFF,,00066,,,,Muss [636],[636] Hinweis: Dieses RFF klassifiziert mit einem Code im DE1153 die in derselben Segmentgruppe enthaltenen DTM zu einem Markt- bzw. Messlokation relevanten Inhalt + 106,Referenz auf die ID der Marktlokation für Termine der Marktlokation,SG6,RFF,1153,00066,Z18,,Marktlokation,X, + 107,Referenz auf die ID der Marktlokation für Termine der Marktlokation,SG6,RFF,1154,00066,,,ID der Marktlokation,X [950],[950] Format: Marktlokations-ID + 108,Turnusablesung des MSB,SG6,DTM,,00067,,,,Muss [21] ∧[234],"[21] Wenn SG10 CCI+++ZA6 (Prognose auf Basis von Profilen) in dieser SG8 vorhanden + [234] Wenn SG10 CCI+++Z83 (Messtechnische Einordnung der Marktlokation) CAV+Z53 (kME/ mME) vorhanden" + 109,Turnusablesung des MSB,SG6,DTM,2005,00067,752,,Turnusablesung,X, + 110,Turnusablesung des MSB,SG6,DTM,2380,00067,,,"Datum oder Uhrzeit oderZeitspanne, Wert",X, + 111,Turnusablesung des MSB,SG6,DTM,2379,00067,104,,MMWW-MMWW,X, + 112,Turnusablesung des MSB,SG6,DTM,2379,,106,,MMDD,X, + 113,Termin der Netznutzungsabrechnung,SG6,DTM,,00068,,,,Muss, + 114,Termin der Netznutzungsabrechnung,SG6,DTM,2005,00068,Z21,,Termin derNetznutzungsabrechnung,X, + 115,Termin der Netznutzungsabrechnung,SG6,DTM,2380,00068,,,"Datum oder Uhrzeit oderZeitspanne, Wert",X, + 116,Termin der Netznutzungsabrechnung,SG6,DTM,2379,00068,106,,MMDD,X, + 117,Termin der Netznutzungsabrechnung,SG6,DTM,2379,,104,,MMWW-MMWW,X, + 118,Nächste Netznutzungsabrechnung,SG6,DTM,,00069,,,,Muss [230],[230] Sich ergebendes Datum/ bzw. Endedatum des Turnuszeitraums aus DTM+Z21 (Termin der Netznutzungsabrechnun g) und DTM+Z09 (Nächste Netznutzungsabrechnun + 119,Nächste Netznutzungsabrechnung,SG6,DTM,2005,00069,Z09,,NächsteNetznutzungsabrechnung,X, + 120,Nächste Netznutzungsabrechnung,SG6,DTM,2380,00069,,,"Datum oder Uhrzeit oderZeitspanne, Wert",X, + 121,Nächste Netznutzungsabrechnung,SG6,DTM,2379,00069,602,,CCYY,X, + 122,Netznutzungsabrechnungsi ntervall des NB,SG6,DTM,,00070,,,,Muss, + 123,Netznutzungsabrechnungsi ntervall des NB,SG6,DTM,2005,00070,Z22,,Netznutzungsabrechnungs- bzw.Einspeisevergütungsintervall des NB,X, + 124,Netznutzungsabrechnungsi ntervall des NB,SG6,DTM,2380,00070,,,"Datum oder Uhrzeit oderZeitspanne, Wert",X, + 125,Netznutzungsabrechnungsi ntervall des NB,SG6,DTM,2379,00070,802,,Monat,X, + 126,Referenz auf die Lokationsbündelstruktur,SG8,,,,,,,Muss [309]∧ [513] ∧[2061],"[309] Wenn DTM+137 (Nachrichtendatum) im DE2380 ≥ 202409302200?+00 + [513] Hinweis: Bei Anwendung dieser Segmentgruppe vor dem 01.10.2024 sind die Codes in diesem Segment noch nicht gültig. Somit wird der Geschäftsvorfall mit einer Verarbeitbarkeitsfehlerm eldung mit Fehlercode Z39 (Code nicht aus erlaubtem Wertebereich“) abgelehnt werden + [2061] Segment bzw. Segmentgruppe ist genau einmal je SG4 IDE (Vorgang) anzugeben" + 127,Referenz auf die Lokationsbündelstruktur,SG8,SEQ,,00071,,,,Muss, + 128,Referenz auf die Lokationsbündelstruktur,SG8,SEQ,1229,00071,Z78,,Referenz auf dieLokationsbündelstruktur,X, + 129,Referenz auf die Lokationsbündelstruktur,SG8,RFF,,00072,,,,Muss, + 130,Referenz auf die Lokationsbündelstruktur,SG8,RFF,1153,00072,Z31,,Lokationsbündelstruktur,X, + 131,Referenz auf die Lokationsbündelstruktur,SG8,RFF,1153,,Z39,,Keine standardisierteLokationsbündelstrukturvorhanden,X, + 132,Referenz auf die Lokationsbündelstruktur,SG8,RFF,1154,00072,,,ID der Lokationsbündelstruktur,X [335],"[335] Wenn im SG8 SEQ+Z78 RFF+Z31 ""Referenz auf die Lokationsbündelstruktur "" im DE1153 der Code Z31 ""Lokationsbündelstruktu r"" vorhanden ist" + 133,Referenz auf die Lokationsbündelstruktur,SG8,RFF,1156,00072,,,Fortlaufende Nummer einesLokationsbündels imGeschäftsvorfall,M [914] ∧[937] [32],"[32] Wenn mehr als ein SG8 SEQ+Z78 (Referenz auf die Lokationsbündelstruktur) vorhanden + [914] Format: Möglicher Wert: > 0 + [937] Format: keine Nachkommastelle" + 134,Zuordnung Lokation zum Objektcode des Lokationsbündels,SG8,,,,,,,Muss [2354]∧ [335] ∧[513],"[335] Wenn im SG8 SEQ+Z78 RFF+Z31 ""Referenz auf die Lokationsbündelstruktur "" im DE1153 der Code Z31 ""Lokationsbündelstruktu r"" vorhanden ist + [513] Hinweis: Bei Anwendung dieser Segmentgruppe vor dem 01.10.2024 sind die Codes in diesem Segment noch nicht gültig. Somit wird der Geschäftsvorfall mit einer Verarbeitbarkeitsfehlerm eldung mit Fehlercode Z39 (Code nicht aus erlaubtem Wertebereich“) abgelehnt werden + [2354] Für jede ID im SG5 LOC+Z16 / Z17 / Z18 / Z20 (Marktlokation / Messlokation /" + 135,Zuordnung Lokation zum Objektcode des Lokationsbündels,SG8,SEQ,,00073,,,,Muss, + 136,Zuordnung Lokation zum Objektcode des Lokationsbündels,SG8,SEQ,1229,00073,Z58,,Zuordnung Lokation zumObjektcode desLokationsbündels,X, + 137,Referenz auf die ID der Netzlokation / Marktlokation / Messlokation / Technischen Ressource,SG8,RFF,,00074,,,,Muss, + 138,Referenz auf die ID der Netzlokation / Marktlokation / Messlokation / Technischen Ressource,SG8,RFF,1153,00074,Z32,,Netzlokation,X, + 139,Referenz auf die ID der Netzlokation / Marktlokation / Messlokation / Technischen Ressource,SG8,RFF,1153,,Z18,,Marktlokation,X, + 140,Referenz auf die ID der Netzlokation / Marktlokation / Messlokation / Technischen Ressource,SG8,RFF,1153,,Z19,,Messlokation,X, + 141,Referenz auf die ID der Netzlokation / Marktlokation / Messlokation / Technischen Ressource,SG8,RFF,1153,,Z37,,Technische Ressource,X, + 142,Referenz auf die ID der Netzlokation / Marktlokation / Messlokation / Technischen Ressource,SG8,RFF,1154,00074,,,ID einer Lokation,X ([451] ∧[950]) ⊻([452] ∧[951]) ⊻([450] ∧[960]) ⊻([456] ∧[922]),"[450] Wenn in demselben RFF der Code Z32 (Netzlokation) im DE1153 vorhanden + [451] Wenn in demselben RFF der Code Z18 (Marktlokation) im DE1153 vorhanden + [452] Wenn in demselben RFF der Code Z19 (Messlokation) im DE1153 vorhanden + [456] Wenn in demselben RFF der Code Z37 (Technische Ressource) im DE1153 vorhanden + [922] Format: TR-ID + [950] Format: Marktlokations-ID + [951] Format: Zählpunktbezeichnung + [960] Format: Netzlokations-ID" + 143,Referenz auf den Objektcode in der Lokationsbündelstruktur,SG8,RFF,,00075,,,,Muss [2313],[2313] Je SG8 SEQ+Z58 (Zuordnung Lokation zum Objektcode des Lokationsbündels) genau einmal anzugeben + 144,Referenz auf den Objektcode in der Lokationsbündelstruktur,SG8,RFF,1153,00075,Z33,,Objektcode der Lokationin derLokationsbündelstruktur,X, + 145,Referenz auf den Objektcode in der Lokationsbündelstruktur,SG8,RFF,1154,00075,,,Objekt Code,X, + 146,Referenz auf den Objektcode in der Lokationsbündelstruktur,SG8,RFF,1156,00075,,,Fortlaufende Nummer einesLokationsbündels imGeschäftsvorfall,M [914] ∧[937] [32],"[32] Wenn mehr als ein SG8 SEQ+Z78 (Referenz auf die Lokationsbündelstruktur) vorhanden + [914] Format: Möglicher Wert: > 0 + [937] Format: keine Nachkommastelle" + 147,Referenz auf die ID der vorgelagerten Netzlokation / Messlokation ,SG8,RFF,,00076,,,,Muss [290],[290] Wenn der Objektcode im RFF+Z33 (Referenz auf den Objektcode in der Lokationsbündelstruktur) im DE1154 derselben SG8 SEQ+Z58 (Zuordnung Lokation zum Objektcode des Lokationsbündels) in einem weiteren SG8 SEQ+Z58 vorhanden ist + 148,Referenz auf die ID der vorgelagerten Netzlokation / Messlokation ,SG8,RFF,1153,00076,Z34,,vorgelagerteMesslokation,X, + 149,Referenz auf die ID der vorgelagerten Netzlokation / Messlokation ,SG8,RFF,1153,,Z35,,vorgelagerteNetzlokation,X, + 150,Referenz auf die ID der vorgelagerten Netzlokation / Messlokation ,SG8,RFF,1154,00076,,,ID einer Lokation,X ([472] ∧[951]) ⊻([471] ∧[960]),"[471] Wenn in demselben RFF der Code Z35 (vorgelagerte Netzlokation) im DE1153 vorhanden + [472] Wenn in demselben RFF der Code Z34 (vorgelagerte Messlokation) im DE1153 vorhanden + [951] Format: Zählpunktbezeichnung " + 151,Referenz auf die der Technischen Ressource zugeordneten Marktlokation ,SG8,RFF,,00077,,,,Muss [290]∧ [291],"[290] Wenn der Objektcode im RFF+Z33 (Referenz auf den Objektcode in der Lokationsbündelstruktur) im DE1154 derselben SG8 SEQ+Z58 (Zuordnung Lokation zum Objektcode des Lokationsbündels) in einem weiteren SG8 SEQ+Z58 vorhanden ist + [291] Wenn in derselben SG8 SEQ+Z58 (Zuordnung Lokation zum Objektcode des Lokationsbündels) das RFF+Z37 vorhanden" + 152,Referenz auf die der Technischen Ressource zugeordneten Marktlokation ,SG8,RFF,1153,00077,Z16,,zugeordneteMarktlokation,X, + 153,Referenz auf die der Technischen Ressource zugeordneten Marktlokation ,SG8,RFF,1154,00077,,,ID der Marktlokation,X [950],[950] Format: Marktlokations-ID + 154,Daten der Netzlokation,SG8,,,,,,,Muss [294]∧ [2356],"[294] Wenn SG5 LOC+Z18 (Netzlokation) vorhanden + [2356] Je SG5 LOC+Z18 (Netzlokation) ist genau einmal die Segmentgruppe anzugeben" + 155,Daten der Netzlokation,SG8,SEQ,,00078,,,,Muss, + 156,Daten der Netzlokation,SG8,SEQ,1229,00078,Z51,,Daten der Netzlokation,X, + 157,Referenz auf die ID der Netzlokation,SG8,RFF,,00079,,,,Muss, + 158,Referenz auf die ID der Netzlokation,SG8,RFF,1153,00079,Z32,,Netzlokation,X, + 159,Referenz auf die ID der Netzlokation,SG8,RFF,1154,00079,,,ID der Netzlokation,X [960],[960] Format: Netzlokations-ID + 160,Steuerkanal,SG10,,,,,,,Muss, + 161,Steuerkanal,SG10,CCI,,00080,,,,Muss, + 162,Steuerkanal,SG10,CCI,7059,00080,Z49,,Steuerkanal,X, + 163,Steuerkanal,SG10,CCI,7037,00080,ZF2,,Kein Steuerkanalvorhanden,X, + 164,Steuerkanal,SG10,CCI,7037,,ZF3,,Steuerkanal vorhanden,X, + 165,Zugeordnete Marktpartner,SG10,,,,,,,Muss, + 166,Zugeordnete Marktpartner,SG10,CCI,,00081,,,,Muss, + 167,Zugeordnete Marktpartner,SG10,CCI,7037,00081,ZB3,,ZugeordneterMarktpartner,X, + 168,Messstellenbetreiber,SG10,CAV,,00082,,,,Muss, + 169,Messstellenbetreiber,SG10,CAV,7111,00082,Z91,,MSB,X, + 170,Messstellenbetreiber,SG10,CAV,1131,00082,,,MP-ID,X, + 171,Messstellenbetreiber,SG10,CAV,7110,00082,Z39,,GrundzuständigerMessstellenbetreiber,X, + 172,Messstellenbetreiber,SG10,CAV,7110,,Z40,,WettbewerblicherMessstellenbetreiber,X, + 173,Messstellenbetreiber,SG10,CAV,7110,,Z41,,Auffangmessstellenbetreiber,X, + 174,OBIS-Daten der Netzlokation,SG8,,,,,,,Soll [166] ∧[294],"[166] Wenn vorhanden + [294] Wenn SG5 LOC+Z18 (Netzlokation) vorhanden" + 175,OBIS-Daten der Netzlokation,SG8,SEQ,,00088,,,,Muss, + 176,OBIS-Daten der Netzlokation,SG8,SEQ,1229,00088,Z57,,OBIS-Daten derNetzlokation,X, + 177,Referenz auf die ID der Netzlokation,SG8,RFF,,00089,,,,Muss, + 178,Referenz auf die ID der Netzlokation,SG8,RFF,1153,00089,Z32,,Netzlokation,X, + 179,Referenz auf die ID der Netzlokation,SG8,RFF,1154,00089,,,ID der Netzlokation,X [960],[960] Format: Netzlokations-ID + 180,OBIS-Kennzahl der Netzlokation,SG8,PIA,,00090,,,,Muss, + 181,OBIS-Kennzahl der Netzlokation,SG8,PIA,4347,00090,5,,Produktidentifikation,X, + 182,OBIS-Kennzahl der Netzlokation,SG8,PIA,7140,00090,,,OBIS-Kennzahl der Netzlokation,X, + 183,OBIS-Kennzahl der Netzlokation,SG8,PIA,7143,00090,SRW,,OBIS-Kennzahl,X, + 184,Produkt-Daten für Lieferant relevant,SG10,,,,,,,Muss, + 185,Produkt-Daten für Lieferant relevant,SG10,CCI,,00093,,,,Muss, + 186,Produkt-Daten für Lieferant relevant,SG10,CCI,7037,00093,ZA7,,LF,X, + 187,Verwendungszweck der Werte,SG10,CAV,,00094,,,,Muss, + 188,Verwendungszweck der Werte,SG10,CAV,7111,00094,Z47,,Endkundenabrechnung,X [1P1..1], + 189,Verwendungszweck der Werte,SG10,CAV,7111,,ZD1,,Blindarbeitabrechnung /Betriebsführung,X [1P1..1], + 190,Produkt-Daten der Netzlokation,SG8,,,,,,,Soll [166] ∧[294],"[166] Wenn vorhanden + [294] Wenn SG5 LOC+Z18 (Netzlokation) vorhanden" + 191,Produkt-Daten der Netzlokation,SG8,SEQ,,00095,,,,Muss, + 192,Produkt-Daten der Netzlokation,SG8,SEQ,1229,00095,Z60,,Produkt-Daten derNetzlokation,X, + 193,Referenz auf die ID der Netzlokation,SG8,RFF,,00096,,,,Muss, + 194,Referenz auf die ID der Netzlokation,SG8,RFF,1153,00096,Z32,,Netzlokation,X, + 195,Referenz auf die ID der Netzlokation,SG8,RFF,1154,00096,,,ID einer Netzlokation,X [960],[960] Format: Netzlokations-ID + 196,Produkt-Daten der Netzlokation,SG8,PIA,,00097,,,,Muss, + 197,Produkt-Daten der Netzlokation,SG8,PIA,4347,00097,5,,Produktidentifikation,X, + 198,Produkt-Daten der Netzlokation,SG8,PIA,7140,00097,,,Konfigurationsprodukt-Code,X [412],"[412] Es sind ausschließlich Konfigurationsprodukt- Codes der ""EDI@Energy Codeliste der Konfigurationen"" aus Kapitel 4.2 Konfigurationsprodukte Leistungskurvendefinitio n erlaubt" + 199,Produkt-Daten der Netzlokation,SG8,PIA,7143,00097,Z12,,Konfigurationsprodukt,X, + 200,Zugeordnete Leistungskurvendefinition,SG10,,,,,,,Muss [190],[190] Wenn in derselben SG8 SEQ+Z60 (Produkt- Daten der Netzlokation) PIA+5+9991000000721: Z12 vorhanden + 201,Zugeordnete Leistungskurvendefinition,SG10,CCI,,00099,,,,Muss, + 202,Zugeordnete Leistungskurvendefinition,SG10,CCI,7059,00099,Z53,,Code derLeistungskurvendefinition,X, + 203,Zugeordnete Leistungskurvendefinition,SG10,CCI,7037,00099,,,Code derLeistungskurvendefinition,X, + 204,Auftraggebender Marktpartner,SG10,,,,,,,Muss, + 205,Auftraggebender Marktpartner,SG10,CCI,,00100,,,,Muss, + 206,Auftraggebender Marktpartner,SG10,CCI,7037,00100,ZB3,,ZugeordneterMarktpartner,X, + 207,Auftraggebender Marktpartner,SG10,CAV,,00101,,,,Muss, + 208,Auftraggebender Marktpartner,SG10,CAV,7111,00101,Z88,,NB,X, + 209,Auftraggebender Marktpartner,SG10,CAV,7111,,Z89,,LF,X, + 210,Auftraggebender Marktpartner,SG10,CAV,1131,00101,,,MP-ID,X, + 211,Produkt-Daten für Marktrolle relevant,SG10,,,,,,,Muss, + 212,Produkt-Daten für Marktrolle relevant,SG10,CCI,,00102,,,,Muss, + 213,Produkt-Daten für Marktrolle relevant,SG10,CCI,7037,00102,ZA7,,LF,X, + 214,Daten der Marktlokation,SG8,,,,,,,Muss [2061],[2061] Segment bzw. Segmentgruppe ist genau einmal je SG4 IDE (Vorgang) anzugeben + 215,Daten der Marktlokation,SG8,SEQ,,00103,,,,Muss, + 216,Daten der Marktlokation,SG8,SEQ,1229,00103,Z01,,Daten der Marktlokation,X, + 217,Referenz auf die ID der Marktlokation,SG8,RFF,,00104,,,,Muss, + 218,Referenz auf die ID der Marktlokation,SG8,RFF,1153,00104,Z18,,Marktlokation,X, + 219,Referenz auf die ID der Marktlokation,SG8,RFF,1154,00104,,,ID der Marktlokation,X [950],[950] Format: Marktlokations-ID + 220,Arbeit / Leistung für tagesparameterabhängige Marktlokation,SG9,,,,,,,Muss [101],[101] Wenn SG10 CCI+++ZA6 (Prognosegrundlage der Marktlokation: Prognose auf Basis von Profilen) CAV+E14/ Z36 (TLP/ TEP/ TEP mit Ref.messung) in dieser SG8 vorhanden + 221,Arbeit / Leistung für tagesparameterabhängige Marktlokation,SG9,QTY,,00105,,,,Muss, + 222,Arbeit / Leistung für tagesparameterabhängige Marktlokation,SG9,QTY,6063,00105,265,,VeranschlagteJahresmenge Gesamt/Jahresverbrauchsprognose für spezifische Arbeit,X, + 223,Arbeit / Leistung für tagesparameterabhängige Marktlokation,SG9,QTY,6060,00105,,,Menge,X [902],[902] Format: Möglicher Wert: ≥ 0 + 224,Arbeit / Leistung für tagesparameterabhängige Marktlokation,SG9,QTY,6411,00105,Z16,,kWh/K (Kilowatt-Stunde/Kelvin),X [103], + 225,Arbeit / Leistung für tagesparameterabhängige Marktlokation,SG9,QTY,6411,,KWH,,Kilowattstunde,X [104],"[103] Wenn SG9 QTY+265 (Arbeit / Leistung für tagesparameterabhängig e Marktlokation: Veranschlagte Jahresmenge Gesamt) in dieser SG8 vorhanden + [104] Wenn SG9 QTY+Z08 (Arbeit / Leistung für tagesparameterabhängig e Marktlokation: angepasste elektrische Arbeit nach Anhang D) in dieser SG8 vorhanden" + 226,Veranschlagte Jahresmenge gesamt,SG9,,,,,,,Muss [106]∨ ([232] ∧[598]),"[106] Wenn in dieser SG8 SEQ+Z01 SG10 CCI+++ZA6 (Prognosegrundlage der Marktlokation: Prognose auf Basis von Profilen) CAV+E02 (SLP/SEP) vorhanden + [232] Wenn SG10 CCI+++Z83 CAV+Z52 (Messtechnische Einordnung der Marktlokation: iMS) vorhanden + [598] Hinweis: Die Übermittlung dieser Angabe dient dazu, dass der LF auch bei iMS gemessenen Marktlokationen mit Prognosegrundlage auf Basis von Werten einen" + 227,Veranschlagte Jahresmenge gesamt,SG9,QTY,,00106,,,,Muss, + 228,Veranschlagte Jahresmenge gesamt,SG9,QTY,6063,00106,31,,VeranschlagteJahresmenge Gesamt,X, + 229,Veranschlagte Jahresmenge gesamt,SG9,QTY,6060,00106,,,Mengenangabe,X [902] ∧[937],"[902] Format: Möglicher Wert: ≥ 0 + [937] Format: keine Nachkommastelle" + 230,Veranschlagte Jahresmenge gesamt,SG9,QTY,6411,00106,KWH,,Kilowattstunde,X, + 231,Lieferrichtung,SG10,,,,,,,Muss, + 232,Lieferrichtung,SG10,CCI,,00110,,,,Muss, + 233,Lieferrichtung,SG10,CCI,7059,00110,Z30,,Lieferrichtung,X, + 234,Lieferrichtung,SG10,CCI,7037,00110,Z07,,Verbrauch,X, + 235,Zugeordnete Marktpartner,SG10,,,,,,,Muss, + 236,Zugeordnete Marktpartner,SG10,CCI,,00111,,,,Muss, + 237,Zugeordnete Marktpartner,SG10,CCI,7037,00111,ZB3,,ZugeordneterMarktpartner,X, + 238,Übertragungsnetzbetreiber,SG10,CAV,,00114,,,,Muss, + 239,Übertragungsnetzbetreiber,SG10,CAV,7111,00114,Z90,,ÜNB,X, + 240,Übertragungsnetzbetreiber,SG10,CAV,1131,00114,,,MP-ID,X, + 241,Messstellenbetreiber,SG10,CAV,,00115,,,,Muss [232]⊻ [234],"[232] Wenn SG10 CCI+++Z83 CAV+Z52 (Messtechnische Einordnung der Marktlokation: iMS) vorhanden + [234] Wenn SG10 CCI+++Z83 (Messtechnische Einordnung der Marktlokation) CAV+Z53 (kME/ mME) vorhanden" + 242,Messstellenbetreiber,SG10,CAV,7111,00115,Z91,,MSB,X, + 243,Messstellenbetreiber,SG10,CAV,1131,00115,,,MP-ID,X, + 244,Messstellenbetreiber,SG10,CAV,7110,00115,Z19,,Auf vertraglicherGrundlage gegenüberAnschlussnutzer /Anschlussnehmer,X, + 245,Messstellenbetreiber,SG10,CAV,7110,,Z20,,In der Ausübung derWeiterverpflichtungdurch den gMSB,X, + 246,Messstellenbetreiber,SG10,CAV,7110,00115,Z39,,GrundzuständigerMessstellenbetreiber,X, + 247,Messstellenbetreiber,SG10,CAV,7110,,Z40,,WettbewerblicherMessstellenbetreiber,X, + 248,Messstellenbetreiber,SG10,CAV,7110,,Z41,,Auffangmessstellenbetreiber,X, + 249,Regelzone,SG10,,,,,,,Muss, + 250,Regelzone,SG10,CCI,,00116,,,,Muss, + 251,Regelzone,SG10,CCI,7059,00116,Z18,,Regelzone,X, + 252,Regelzone,SG10,CCI,7037,00116,,,Regelzone,X, + 253,Bilanzkreis,SG10,,,,,,,Muss [2061]∧ [64],"[64] Wenn SG4 DTM+158 (Bilanzierungsbeginn) vorhanden + [2061] Segment bzw. Segmentgruppe ist genau einmal je SG4 IDE (Vorgang) anzugeben" + 254,Bilanzkreis,SG10,CCI,,00117,,,,Muss, + 255,Bilanzkreis,SG10,CCI,7059,00117,Z19,,Bilanzkreis,X, + 256,Bilanzkreis,SG10,CCI,7037,00117,,,Bilanzkreis,X, + 257,Bilanzierungsgebiet,SG10,,,,,,,Muss, + 258,Bilanzierungsgebiet,SG10,CCI,,00118,,,,Muss, + 259,Bilanzierungsgebiet,SG10,CCI,7059,00118,Z20,,Bilanzierungsgebiet,X, + 260,Bilanzierungsgebiet,SG10,CCI,7037,00118,,,Bilanzierungsgebiet,X, + 261,Verbrauchsaufteilung für temperaturabhängige Marktlokation,SG10,,,,,,,Muss [89] ∧[106],"[89] Wenn im SG8 SEQ+Z01 (Daten der Marktlokation) das SG10 CCI+++ZA6 (Prognosegrundlage der Marktlokation: Prognose auf Basis von Profilen) CAV+E14 (TLP/TEP) vorhanden + [106] Wenn in dieser SG8 SEQ+Z01 SG10 CCI+++ZA6 (Prognosegrundlage der Marktlokation: Prognose auf Basis von Profilen) CAV+E02 (SLP/SEP) vorhanden" + 262,Verbrauchsaufteilung für temperaturabhängige Marktlokation,SG10,CCI,,00119,,,,Muss, + 263,Verbrauchsaufteilung für temperaturabhängige Marktlokation,SG10,CCI,7037,00119,E17,,Verbrauchsaufteilung (in,X, + 264,Verbrauchsaufteilung für temperaturabhängige Marktlokation,SG10,CAV,,00120,,,,Muss, + 265,Verbrauchsaufteilung für temperaturabhängige Marktlokation,SG10,CAV,7111,00120,Z22,,Verbrauchsaufteilung in%,X, + 266,Verbrauchsaufteilung für temperaturabhängige Marktlokation,SG10,CAV,7110,00120,,,Verbrauchsaufteilung in %,X [902],[902] Format: Möglicher Wert: ≥ 0 + 267,Zeitreihentyp,SG10,,,,,,,Muss [2061]⊻ ([90] ∧[2096]),"[90] Wenn SG10 CCI+++ZA6 (Prognosegrundlage der Marktlokation: Prognose auf Basis von Profilen) einmal mit CAV+E14 (TLP/TEP) und einmal mit CAV+E02 (SLP/SEP) in dieser SG8 vorhanden + [2061] Segment bzw. Segmentgruppe ist genau einmal je SG4 IDE (Vorgang) anzugeben + [2096] Segmentgruppe ist genau zweimal je SG4 IDE anzugeben" + 268,Zeitreihentyp,SG10,CCI,,00121,,,,Muss, + 269,Zeitreihentyp,SG10,CCI,7059,00121,15,,Struktur,X, + 270,Zeitreihentyp,SG10,CCI,7037,00121,Z21,,Summenzeitreihentyp,X, + 271,Zeitreihentyp,SG10,CAV,,00122,,,,Muss, + 272,Zeitreihentyp,SG10,CAV,7111,00122,,,Code des Zeitreihentyps,X, + 273,Spannungsebene der Marktlokation,SG10,,,,,,,Muss, + 274,Spannungsebene der Marktlokation,SG10,CCI,,00123,,,,Muss, + 275,Spannungsebene der Marktlokation,SG10,CCI,7037,00123,E03,,Spannungsebene derMarktlokation,X, + 276,Spannungsebene der Marktlokation,SG10,CAV,,00124,,,,Muss, + 277,Spannungsebene der Marktlokation,SG10,CAV,7111,00124,E03,,Höchstspannung,X, + 278,Spannungsebene der Marktlokation,SG10,CAV,7111,,E04,,Hochspannung,X, + 279,Spannungsebene der Marktlokation,SG10,CAV,7111,,E05,,Mittelspannung,X, + 280,Umspannung der Marktlokation,SG10,CAV,,00125,,,,Soll [166],[166] Wenn vorhanden + 281,Umspannung der Marktlokation,SG10,CAV,7111,00125,E07,,Hös/HS Umspannung,X [116], + 282,Umspannung der Marktlokation,SG10,CAV,7111,,E08,,HS/MS Umspannung,X [115], + 283,Umspannung der Marktlokation,SG10,CAV,7111,,E09,,MS/NS Umspannung,X [114],"[114] Wenn das SG10 CCI+E03 (Spannungsebene der Marktlokation) CAV E06 (Niederspannung) in dieser SG vorhanden + [115] Wenn das SG10 CCI+E03 (Spannungsebene der Marktlokation) CAV E05 (Mittelspannung) in dieser SG vorhanden + [116] Wenn das SG10 CCI+E03 (Spannungsebene der Marktlokation) CAV E04 (Hochspannung) in dieser SG vorhanden" + 284,Messtechnische Einordnung der Marktlokation,SG10,,,,,,,Muss, + 285,Messtechnische Einordnung der Marktlokation,SG10,CCI,,00126,,,,Muss, + 286,Messtechnische Einordnung der Marktlokation,SG10,CCI,7037,00126,Z83,,MesstechnischeEinordnung derMarktlokation,X, + 287,Messtechnische Einordnung der Marktlokation,SG10,CAV,,00127,,,,Muss, + 288,Messtechnische Einordnung der Marktlokation,SG10,CAV,7111,00127,Z52,,iMS,X, + 289,Messtechnische Einordnung der Marktlokation,SG10,CAV,7111,,Z53,,kME / mME,X, + 290,Messtechnische Einordnung der Marktlokation,SG10,CAV,7111,,Z68,,keine Messung,X, + 291,Aggregationsverantwortung in MaBiS,SG10,,,,,,,Muss, + 292,Aggregationsverantwortung in MaBiS,SG10,CCI,,00128,,,,Muss, + 293,Aggregationsverantwortung in MaBiS,SG10,CCI,7059,00128,6,,Verantwortlicher,X, + 294,Aggregationsverantwortung in MaBiS,SG10,CCI,7037,00128,ZA8,,NB,X, + 295,Aggregationsverantwortung in MaBiS,SG10,CCI,7037,,ZA9,,ÜNB,X, + 296,Prognosegrundlage der Marktlokation,SG10,,,,,,,Muss, + 297,Prognosegrundlage der Marktlokation,SG10,CCI,,00130,,,,Muss, + 298,Prognosegrundlage der Marktlokation,SG10,CCI,7037,00130,ZC0,,Prognose auf Basis von,X, + 299,Details der Prognosegrundlage,SG10,CAV,,00131,,,,Muss [21] ∧([2182] ⊻([90] ∧[2183])),"[21] Wenn SG10 CCI+++ZA6 (Prognose auf Basis von Profilen) in dieser SG8 vorhanden + [90] Wenn SG10 CCI+++ZA6 (Prognosegrundlage der Marktlokation: Prognose auf Basis von Profilen) einmal mit CAV+E14 (TLP/TEP) und einmal mit CAV+E02 (SLP/SEP) in dieser SG8 vorhanden + [2182] Segmentgruppe ist genau einmal je SG8 SEQ+Z01 (Daten der Marktlokation) anzugeben + [2183] Segmentgruppe ist genau zweimal je SG8 SEQ+Z01 (Daten der Marktlokation) anzugeben" + 300,Details der Prognosegrundlage,SG10,CAV,7111,00131,E02,,SLP/SEP,X [6P0..1] ⊻[7P1..1], + 301,Details der Prognosegrundlage,SG10,CAV,7111,,E14,,TLP/TEP,X [6P0..1], + 302,Wahlrecht der Prognosegrundlage der Marktlokation,SG10,,,,,,,Muss [244],[244] Wenn SG10 CCI+6++ZA9 (Aggreg. verantw. ÜNB) in dieser SG8 vorhanden + 303,Wahlrecht der Prognosegrundlage der Marktlokation,SG10,CCI,,00134,,,,Muss, + 304,Wahlrecht der Prognosegrundlage der Marktlokation,SG10,CCI,7037,00134,Z84,,Wahlrecht derPrognosegrundlage,X, + 305,Wahlrecht der Prognosegrundlage der Marktlokation,SG10,CAV,,00135,,,,Muss, + 306,Wahlrecht der Prognosegrundlage der Marktlokation,SG10,CAV,7111,00135,Z54,,Wahlrecht durch LFgegeben,X, + 307,Wahlrecht der Prognosegrundlage der Marktlokation,SG10,CAV,7111,,ZE2,,Wahlrecht durch LF nicht,X, + 308,Grund für nicht vorhandenes Wahlrecht der Prognosegrundlage der Marktlokation,SG10,CAV,,00136,,,,Muss [247],[247] Wenn CAV+ZE2 (Wahlrecht durch LF nicht gegeben) vorhanden + 309,Grund für nicht vorhandenes Wahlrecht der Prognosegrundlage der Marktlokation,SG10,CAV,7111,00136,Z55,,Wahlrecht nichtvorhanden wegenVerbrauch > 10.000kWh/a,X [1P0..1], + 310,Grund für nicht vorhandenes Wahlrecht der Prognosegrundlage der Marktlokation,SG10,CAV,7111,,ZC1,,Wahlrecht nichtvorhanden wegenEigenverbrauch,X [1P0..1], + 311,Grund für nicht vorhandenes Wahlrecht der Prognosegrundlage der Marktlokation,SG10,CAV,7111,,ZD2,,Wahlrecht nichtvorhanden wegentagesparameterabhängigem Verbrauch,X [1P0..1], + 312,Grund für nicht vorhandenes Wahlrecht der Prognosegrundlage der Marktlokation,SG10,CAV,7111,,ZE3,,Wahlrecht nichtvorhanden wegen § 14aEnWG,X [1P0..1], + 313,Gruppenzuordnung (nach EnWG) ,SG10,,,,,,,Muss, + 314,Gruppenzuordnung (nach EnWG) ,SG10,CCI,,00139,,,,Muss, + 315,Gruppenzuordnung (nach EnWG) ,SG10,CCI,7037,00139,Z15,,Haushaltskunde gem.EnWG,X, + 316,Gruppenzuordnung (nach EnWG) ,SG10,CCI,7037,,Z18,,Kein Haushaltskundegem. EnWG,X, + 317,Netznutzung,SG10,,,,,,,Muss, + 318,Netznutzung,SG10,CCI,,00140,,,,Muss, + 319,Netznutzung,SG10,CCI,7037,00140,Z88,,Netznutzung,X, + 320,Netznutzungsvertrag,SG10,CAV,,00141,,,,Muss, + 321,Netznutzungsvertrag,SG10,CAV,7111,00141,Z74,,Netznutzungsvertrag,X, + 322,Netznutzungsvertrag,SG10,CAV,7110,00141,Z08,,Direkter Vertragzwischen Kunden und NB,X, + 323,Netznutzungsvertrag,SG10,CAV,7110,,Z09,,Vertrag zwischenLieferanten und NB,X, + 324,Zahlung der Netznutzung,SG10,CAV,,00142,,,,Muss, + 325,Zahlung der Netznutzung,SG10,CAV,7111,00142,Z73,,Zahlung der Netznutzung,X, + 326,Zahlung der Netznutzung,SG10,CAV,7110,00142,Z10,,Kunde,X [216], + 327,Zahlung der Netznutzung,SG10,CAV,7110,,Z11,,Lieferant,X,[216] Wenn CCI+++Z88 (Netznutzung) CAV+Z74:::Z08 + 328,Netznutzungsabrechnungsv ariante,SG10,CAV,,00143,,,,Muss, + 329,Netznutzungsabrechnungsv ariante,SG10,CAV,7111,00143,ZB1,,Netznutzungsabrechnungsvariante,X, + 330,Netznutzungsabrechnungsv ariante,SG10,CAV,7110,00143,Z14,,Arbeitspreis/Grundpreis,X, + 331,Netznutzungsabrechnungsv ariante,SG10,CAV,7110,,Z15,,Arbeitspreis/Leistungspreis,X, + 332,Grundlage der Lieferscheinprüfung,SG10,CAV,,00144,,,,Muss, + 333,Grundlage der Lieferscheinprüfung,SG10,CAV,7111,00144,ZA7,,Grundlage fürLieferscheinprüfung,X, + 334,Grundlage der Lieferscheinprüfung,SG10,CAV,7110,00144,Z12,,In derMarktkommunikationausgetauschte Daten,X, + 335,Grundlage der Lieferscheinprüfung,SG10,CAV,7110,,Z13,,Abweichend vertraglichmit Anschlussnutzervereinbarte Grundlage,X, + 336,Versorgungsart der Marktlokation,SG10,,,,,,,Muss, + 337,Versorgungsart der Marktlokation,SG10,CCI,,00151,,,,Muss, + 338,Versorgungsart der Marktlokation,SG10,CCI,7059,00151,Z36,,Versorgungsart derMarktlokation,X, + 339,Versorgungsart der Marktlokation,SG10,CCI,7037,00151,ZC9,,Ersatzversorgung,X, + 340,Versorgungsart der Marktlokation,SG10,CCI,7037,,ZD0,,Grundversorgung,X, + 341,Versorgungsart der Marktlokation,SG10,CCI,7037,,ZE3,,Ersatzbelieferung,X, + 342,Betriebszustand der Marktlokation,SG10,,,,,,,, + 343,Betriebszustand der Marktlokation,SG10,CCI,,00152,,,,, + 344,Betriebszustand der Marktlokation,SG10,CCI,7059,00152,Z42,,Betriebszustand derMarktlokation,, + 345,Betriebszustand der Marktlokation,SG10,CCI,7037,00152,ZB9,,Marktlokation gesperrt,, + 346,Betriebszustand der Marktlokation,SG10,CCI,7037,,ZD3,,Marktlokation imRegelbetrieb,, + 347,Abwicklungsmodell,SG10,,,,,,,Muss, + 348,Abwicklungsmodell,SG10,CCI,,00153,,,,Muss, + 349,Abwicklungsmodell,SG10,CCI,7059,00153,ZA2,,Abwicklungsmodell,X, + 350,Abwicklungsmodell,SG10,CCI,7037,00153,ZE9,,"Modell 1 ""Bilanzierungan der Marktlokation""",X, + 351,Netznutzungsabrechnungsd aten der Marktlokation,SG8,,,,,,,Muss [225],[225] Wenn CCI+++Z88 (Netznutzung) CAV+Z73:::Z11 (Zahlung der Netznutzung: Lieferant) vorhanden + 352,Netznutzungsabrechnungsd aten der Marktlokation,SG8,SEQ,,00170,,,,Muss, + 353,Netznutzungsabrechnungsd aten der Marktlokation,SG8,SEQ,1229,00170,Z45,,Netznutzungsabrechnungsdaten derMarktlokation,X, + 354,Gruppenartikel-ID / Artikel- ID,SG8,PIA,,00171,,,,Muss, + 355,Gruppenartikel-ID / Artikel- ID,SG8,PIA,4347,00171,Z02,,Gruppenartikel-ID /Artikel-ID,X, + 356,Gruppenartikel-ID / Artikel- ID,SG8,PIA,7140,00171,,,Produkt-/Leistungsnummer,X ([942]([270] ⊻[282]) ∧[284]) ⊻ ([943] ([259]⊻ [261]) ∧[284]) ⊻([957] [285]∧ [287]) ⊻([948] [286]∧ [287]) ,"[259] Wenn in diesem PIA der Code im DE7140 mit 1-01, 1-03, 1-05 enthalten ist + [261] Wenn in diesem PIA der Code im DE7140 mit 1-07-1/2, 1-10-1/2/ 4/5/6/7/8/9, 1-11-1 beginnt + [270] Wenn in diesem PIA der Code im DE7140 mit 1-02, 1-04, 1-06, 1- 09 beginnt + [282] Wenn in diesem PIA der Code im DE7140 1-01-6-005, 1-01-9-001, 1-07-3-001, 1-08-1-001, 1-08-3-001, 1-08-4- 001/002/003/004, 1- 10-3-001 enthalten ist + [284] Erlaubte Codes aus der Codeliste der Gruppenartikel- und Artikel-ID sind in der Spalte UTILMD/ Codeverwendung mit X gekennzeichnet + [285] Wenn in diesem PIA der Code im DE7140 mit 1-08-3-AGS angegeben ist + [286] Wenn in diesem PIA der Code im DE7140" + 357,Gruppenartikel-ID / Artikel- ID,SG8,PIA,7143,00171,Z09,,Artikel-ID,X [393] ⊻([394] ∧[397]) ⊻[395], + 358,Gruppenartikel-ID / Artikel- ID,SG8,PIA,7143,,Z10,,Gruppenartikel-ID,X [392] ⊻([394] ∧[398]),"[392] Wenn in diesem PIA der Code im Format n1-n2-n1 angegeben ist + [393] Wenn in diesem PIA der Code im Format n1-n2-n1-n3 angegeben ist + [394] Wenn in diesem PIA der Code im Format n1-n2-n1-n8-n2 angegeben ist + [395] Wenn in diesem PIA der Code im Format n1-n2-n1-n8 angegeben ist + [397] Wenn in diesem PIA der Code im DE7140 mit 1-08-1/1-08-4 beginnt + [398] Wenn in diesem PIA der Code im DE7140 mit 1-08-2/1-08-5 beginnt" + 359,Anzahl in der NNA abzurechenden Positionen der Gruppenartikel-ID / Artikel-ID,SG9,,,,,,,Muss [237],[237] Wenn in derselben SG8 im DE7140 des PIA+Z02 (Gruppenartikel-ID / Artikel-ID) eine + 360,Anzahl in der NNA abzurechenden Positionen der Gruppenartikel-ID / Artikel-ID,SG9,QTY,,00172,,,,Muss, + 361,Anzahl in der NNA abzurechenden Positionen der Gruppenartikel-ID / Artikel-ID,SG9,QTY,6063,00172,Z38,,Anzahl derabzurechendenPositionen derGruppenartikel-ID /Artikel-ID,X, + 362,Anzahl in der NNA abzurechenden Positionen der Gruppenartikel-ID / Artikel-ID,SG9,QTY,6060,00172,,,Menge,X [914] ∧[937],"[914] Format: Möglicher Wert: > 0 + [937] Format: keine Nachkommastelle" + 363,Anzahl in der NNA abzurechenden Positionen der Gruppenartikel-ID / Artikel-ID,SG9,QTY,6411,00172,PCS,,Stück,X, + 364,Gemeinderabatt,SG9,,,,,,,Muss, + 365,Gemeinderabatt,SG9,QTY,,00173,,,,Muss, + 366,Gemeinderabatt,SG9,QTY,6063,00173,Z16,,Gemeinderabatt,X, + 367,Gemeinderabatt,SG9,QTY,6060,00173,,,Menge,X [902] ∧[930] ∧[938],"[902] Format: Möglicher Wert: ≥ 0 + [930] Format: max. 2 Nachkommastellen + [938] Format: Möglicher Wert: <= 10" + 368,Gemeinderabatt,SG9,QTY,6411,00173,P1,,Prozent,X, + 369,Zuschlag oder Abschlag,SG9,,,,,,,Muss, + 370,Zuschlag oder Abschlag,SG9,QTY,,00174,,,,Muss, + 371,Zuschlag oder Abschlag,SG9,QTY,6063,00174,Z34,,Zuschlag,X, + 372,Zuschlag oder Abschlag,SG9,QTY,6063,,Z35,,Abschlag,X, + 373,Zuschlag oder Abschlag,SG9,QTY,6063,,Z37,,Kein Zu-/Abschlag,X, + 374,Zuschlag oder Abschlag,SG9,QTY,6060,00174,,,Menge,X ([914] ∧[930] [140])⊻ ([926] ∧[937] [172]),"[140] Wenn im selben QTY im DE6063 Z34/Z35 (Zuschlag/Abschlag) vorhanden + [172] Wenn im selben QTY im DE6063 Z37 (Kein Zu- und Abschlag) vorhanden + [914] Format: Möglicher Wert: > 0 + [926] Format: Möglicher Wert: 0 + [930] Format: max. 2" + 375,Zuschlag oder Abschlag,SG9,QTY,6411,00174,P1,,Prozent,X, + 376,Menge der Singulär genutzten Betriebsmittel,SG9,,,,,,,Muss [73],"[73] Wenn in derselben SG8 im PIA DE7140 ein Code aus der Codeliste der Gruppenartikel- und Artikel-ID vorhanden ist, der in der Spalte UTILMD/Preisangabe mit X gekennzeichnet ist" + 377,Menge der Singulär genutzten Betriebsmittel,SG9,QTY,,00175,,,,Muss, + 378,Menge der Singulär genutzten Betriebsmittel,SG9,QTY,6063,00175,Z33,,Singulär genutzteBetriebsmittel,X, + 379,Menge der Singulär genutzten Betriebsmittel,SG9,QTY,6060,00175,,,Menge,X, + 380,Preisangabe für Singulär genutzte Betriebsmittel,SG10,,,,,,,Muss [73],"[73] Wenn in derselben SG8 im PIA DE7140 ein Code aus der Codeliste der Gruppenartikel- und Artikel-ID vorhanden ist, der in der Spalte UTILMD/Preisangabe mit X gekennzeichnet ist" + 381,Preisangabe für Singulär genutzte Betriebsmittel,SG10,CCI,,00176,,,,Muss, + 382,Preisangabe für Singulär genutzte Betriebsmittel,SG10,CCI,7059,00176,Z44,,Berechnungspreis,X, + 383,Preisangabe für Singulär genutzte Betriebsmittel,SG10,CCI,7037,00176,ZD8,,Tag,X, + 384,Preisangabe für Singulär genutzte Betriebsmittel,SG10,CCI,7036,00176,,,"Preis, Betrag",X [914] ∧[946],"[914] Format: Möglicher Wert: > 0 + [946] Format: max. 11 Nachkommastellen" + 385,Zugeordnete Zählzeitdefinition,SG10,,,,,,,Muss [59] ∧[108],"[59] Wenn mehr als eine SG8 SEQ+Z45 (Netznutzungsabrechnun gsdaten der Marktlokation) mit einer Gruppen-/Artikel-ID im SG8 PIA+Z02 (Gruppenartikel-ID / Artikel-ID), welche mit 1-08-1/2/3/4/5 beginnt, vorhanden + [108] Wenn in derselben SG8 SEQ+Z45" + 386,Zugeordnete Zählzeitdefinition,SG10,CCI,,00177,,,,Muss, + 387,Zugeordnete Zählzeitdefinition,SG10,CCI,7059,00177,Z39,,Code derZählzeitdefinition,X, + 388,Zugeordnete Zählzeitdefinition,SG10,CCI,7037,00177,,,Code der Zählzeitdefinition,X, + 389,Zugeordnetes Zählzeitregister ,SG10,,,,,,,Muss [59] ∧[108],"[59] Wenn mehr als eine SG8 SEQ+Z45 (Netznutzungsabrechnun gsdaten der Marktlokation) mit einer Gruppen-/Artikel-ID im SG8 PIA+Z02 (Gruppenartikel-ID / Artikel-ID), welche mit 1-08-1/2/3/4/5 beginnt, vorhanden + [108] Wenn in derselben SG8 SEQ+Z45 (Netznutzungsabrechnun gsdaten der Marktlokation) eine Gruppen-/Artikel-ID im SG8 PIA+Z02 (Gruppenartikel-ID / Artikel-ID), welche mit 1-08-1/2/3/4/5 beginnt, vorhanden" + 390,Zugeordnetes Zählzeitregister ,SG10,CCI,,00178,,,,Muss, + 391,Zugeordnetes Zählzeitregister ,SG10,CCI,7059,00178,Z38,,Code desZählzeitregisters,X, + 392,Zugeordnetes Zählzeitregister ,SG10,CCI,7037,00178,,,Code des Zählzeitregisters,X, + 393,OBIS-Daten der Marktlokation,SG8,,,,,,,Muss, + 394,OBIS-Daten der Marktlokation,SG8,SEQ,,00198,,,,Muss, + 395,OBIS-Daten der Marktlokation,SG8,SEQ,1229,00198,Z02,,OBIS-Daten derMarktlokation,X, + 396,Referenz auf die ID der Marktlokation,SG8,RFF,,00199,,,,Muss, + 397,Referenz auf die ID der Marktlokation,SG8,RFF,1153,00199,Z18,,Marktlokation,X, + 398,Referenz auf die ID der Marktlokation,SG8,RFF,1154,00199,,,ID einer Marktlokation,X [950],[950] Format: Marktlokations-ID + 399,OBIS-Kennzahl der Marktlokation,SG8,PIA,,00200,,,,Muss, + 400,OBIS-Kennzahl der Marktlokation,SG8,PIA,4347,00200,5,,Produktidentifikation,X, + 401,OBIS-Kennzahl der Marktlokation,SG8,PIA,7140,00200,,,OBIS-Kennzahl der Marktlokation,X [314],"[314] Es sind alle OBIS- Kennzahlen gem. EDI@Energy Codeliste der OBIS-Kennzahlen und Medien für den deutschen Energiemarkt Kap. 3 anzugeben, welche an der Marktlokation erforderlich sind. Der Mindestumfang der OBIS-Kennzahlen ergibt sich aus den genannten Messprodukt-Codes dem Kap. 5.1 des Dokumentes ""Codeliste der Konfigurationen""" + 402,OBIS-Kennzahl der Marktlokation,SG8,PIA,7143,00200,SRW,,OBIS-Kennzahl,X, + 403,Wertegranularität,SG10,,,,,,,Muss [257],[257] Wenn in derselben SG8 SEQ+Z02 (OBIS- Daten der Marktlokation) das PIA+5+1-b?:1.9.e vorhanden + 404,Wertegranularität,SG10,CCI,,00201,,,,Muss, + 405,Wertegranularität,SG10,CCI,7037,00201,ZE4,,Wertegranularität,X, + 406,Wertegranularität,SG10,CAV,,00202,,,,Muss, + 407,Wertegranularität,SG10,CAV,7111,00202,ZD9,,Jährlich,X, + 408,Wertegranularität,SG10,CAV,7111,,ZE8,,Halbjährlich,X, + 409,Wertegranularität,SG10,CAV,7111,,ZE9,,Quartalsweise,X, + 410,Wertegranularität,SG10,CAV,7111,,ZB7,,Monatlich,X, + 411,Zugeordnete Zählzeitdefinition,SG10,,,,,,,Muss [386]∧ [387],[386] Wenn mehr als eine SG8 SEQ+Z02 (OBIS-Daten der Marktlokation) mit einer OBIS-Kennzahl für Energiemenge im PIA+5 vorhanden + 412,Zugeordnete Zählzeitdefinition,SG10,CCI,,00203,,,,Muss, + 413,Zugeordnete Zählzeitdefinition,SG10,CCI,7059,00203,Z39,,Code derZählzeitdefinition,X, + 414,Zugeordnete Zählzeitdefinition,SG10,CCI,7037,00203,,,Code der Zählzeitdefinition,X, + 415,Zugeordnetes Zählzeitregister ,SG10,,,,,,,Muss [421],[421] Wenn in dieser SG8 das SG10 CCI+Z39 (Zugeordnete Zählzeitdefinition) vorhanden ist + 416,Zugeordnetes Zählzeitregister ,SG10,CCI,,00204,,,,Muss, + 417,Zugeordnetes Zählzeitregister ,SG10,CCI,7059,00204,Z38,,Code desZählzeitregisters,X, + 418,Zugeordnetes Zählzeitregister ,SG10,CCI,7037,00204,,,Code des Zählzeitregisters,X, + 419,OBIS Daten für Lieferant relevant,SG10,,,,,,,Muss, + 420,OBIS Daten für Lieferant relevant,SG10,CCI,,00207,,,,Muss, + 421,OBIS Daten für Lieferant relevant,SG10,CCI,7037,00207,ZA7,,LF,X, + 422,Verwendungszweck der Werte,SG10,CAV,,00208,,,,Muss, + 423,Verwendungszweck der Werte,SG10,CAV,7111,00208,Z84,,Netznutzungsabrechnun,X [29P0..1] ⊻[30P0..1] ⊻[32P0..1] ⊻[36P0..1], + 424,Verwendungszweck der Werte,SG10,CAV,7111,,Z85,,Bilanzkreisabrechnung,X [31P1..1] ⊻[32P1..1], + 425,Verwendungszweck der Werte,SG10,CAV,7111,,Z86,,Mehrmindermengenabrechnung,X [30P1..1], + 426,Verwendungszweck der Werte,SG10,CAV,7111,,Z47,,Endkundenabrechnung,X [28P0..1] ⊻[29P1..1] ⊻[30P0..1] ⊻[32P1..1] ⊻[36P0..1], + 427,Verwendungszweck der Werte,SG10,CAV,7111,,ZD1,,Blindarbeitabrechnung /Betriebsführung,X [28P0..1], + 428,Produkt-Daten der Marktlokation,SG8,,,,,,,Soll [166],[166] Wenn vorhanden + 429,Produkt-Daten der Marktlokation,SG8,SEQ,,00211,,,,Muss, + 430,Produkt-Daten der Marktlokation,SG8,SEQ,1229,00211,Z59,,Produkt-Daten derMarktlokation,X, + 431,Referenz auf die ID der Marktlokation,SG8,RFF,,00212,,,,Muss, + 432,Referenz auf die ID der Marktlokation,SG8,RFF,1153,00212,Z18,,Marktlokation,X, + 433,Referenz auf die ID der Marktlokation,SG8,RFF,1154,00212,,,ID einer Marktlokation,X [950],[950] Format: Marktlokations-ID + 434,Produkt-Daten der Marktlokation,SG8,PIA,,00213,,,,Muss, + 435,Produkt-Daten der Marktlokation,SG8,PIA,4347,00213,5,,Produktidentifikation,X, + 436,Produkt-Daten der Marktlokation,SG8,PIA,7140,00213,,,Produkt-/Leistungsnummer,X, + 437,Produkt-Daten der Marktlokation,SG8,PIA,7143,00213,Z12,,Konfigurationsprodukt,X, + 438,Zugeordnete Definition,SG10,,,,,,,Muss, + 439,Zugeordnete Definition,SG10,CCI,,00214,,,,Muss, + 440,Zugeordnete Definition,SG10,CCI,7059,00214,Z53,,Code derLeistungskurvendefinition,X, + 441,Zugeordnete Definition,SG10,CCI,7037,00214,,,Code der Definition,X, + 442,Produkt-Daten für Marktrolle relevant,SG10,,,,,,,Muss, + 443,Produkt-Daten für Marktrolle relevant,SG10,CCI,,00215,,,,Muss, + 444,Produkt-Daten für Marktrolle relevant,SG10,CCI,7037,00215,ZA7,,LF,X, + 445,Verbrauchsart und Nutzung der OBIS-Kennzahl der Marktlokation,SG8,,,,,,,Muss [298],[298] Wenn SG5 LOC+Z20 (Technische Ressource) nicht vorhanden + 446,Verbrauchsart und Nutzung der OBIS-Kennzahl der Marktlokation,SG8,SEQ,,00216,,,,Muss, + 447,Verbrauchsart und Nutzung der OBIS-Kennzahl der Marktlokation,SG8,SEQ,1229,00216,Z44,,Verbrauchsart undNutzung der OBIS-Kennzahl an derMarktlokation,X, + 448,Referenz auf die OBIS- Kennzahl der Marktlokation,SG8,RFF,,00217,,,,Muss, + 449,Referenz auf die OBIS- Kennzahl der Marktlokation,SG8,RFF,1153,00217,Z10,,OBIS-Kennzahl,X, + 450,Referenz auf die OBIS- Kennzahl der Marktlokation,SG8,RFF,1154,00217,,,OBIS-Kennzahl,X, + 451,Verbrauchsart und Nutzung an der OBIS-Kennzahl der Marktlokation,SG10,,,,,,,Muss, + 452,Verbrauchsart und Nutzung an der OBIS-Kennzahl der Marktlokation,SG10,CCI,,00218,,,,Muss, + 453,Verbrauchsart und Nutzung an der OBIS-Kennzahl der Marktlokation,SG10,CCI,7059,00218,Z17,,Stromverbrauchsart,X, + 454,Verbrauchsart,SG10,CAV,,00219,,,,Muss, + 455,Verbrauchsart,SG10,CAV,7111,00219,Z64,,Kraft/Licht,X [1P0..1], + 456,Verbrauchsart,SG10,CAV,7111,,Z65,,Wärme,X [1P0..1], + 457,Verbrauchsart,SG10,CAV,7111,,ZE5,,E-Mobilität,X [1P0..1], + 458,Verbrauchsart,SG10,CAV,7111,,ZA8,,Straßenbeleuchtung,X [1P0..1], + 459,Verbrauchsart,SG10,CAV,7111,,ZB3,,SteuerungWärmeabgabe,X [1P0..1], + 460,Unterbrechbarkeit,SG10,CAV,,00220,,,,Muss, + 461,Unterbrechbarkeit,SG10,CAV,7111,00220,Z62,,unterbrechbareVerbrauchseinrichtung,X, + 462,Unterbrechbarkeit,SG10,CAV,7111,,Z63,,nicht-unterbrechbareVerbrauchseinrichtung,X, + 463,Wärmenutzung,SG10,CAV,,00221,,,,Muss [239],[239] Wenn in derselben SG10 das CCI+Z17 (Stromverbrauchsart) im CAV+Z65 (Wärme) vorhanden + 464,Wärmenutzung,SG10,CAV,7111,00221,Z56,,Speicherheizung,X, + 465,Wärmenutzung,SG10,CAV,7111,,Z57,,Wärmepumpe,X, + 466,Wärmenutzung,SG10,CAV,7111,,Z61,,Direktheizung,X, + 467,Art der E-Mobilität,SG10,CAV,,00222,,,,Muss [95],[95] Wenn in derselben SG10 das CCI+Z17 (Stromverbrauchsart) CAV+ZE5 (E-Mobilität) vorhanden + 468,Art der E-Mobilität,SG10,CAV,7111,00222,ZE6,,Wallbox,X, + 469,Art der E-Mobilität,SG10,CAV,7111,,Z87,,E-Mobilitätsladesäule,X, + 470,Art der E-Mobilität,SG10,CAV,7111,,ZE7,,Ladepark,X, + 471,Daten der Technischen Ressource,SG8,,,,,,,Muss [296]∧ [2357],"[296] Wenn SG5 LOC+Z20 (Technische Ressource) vorhanden + [2357] Je SG5 LOC+Z20 (Technische Ressource) ist genau einmal die Segmentgruppe" + 472,Daten der Technischen Ressource,SG8,SEQ,,00273,,,,Muss, + 473,Daten der Technischen Ressource,SG8,SEQ,1229,00273,Z52,,Daten der TechnischenRessource,X, + 474,Referenz auf die ID der Technischen Ressource,SG8,RFF,,00274,,,,Muss, + 475,Referenz auf die ID der Technischen Ressource,SG8,RFF,1153,00274,Z37,,Technische Ressource,X, + 476,Referenz auf die ID der Technischen Ressource,SG8,RFF,1154,00274,,,ID der Technischen Ressource,X [922],[922] Format: TR-ID + 477,Referenz auf die ID der vorgelagerten Messlokation,SG8,RFF,,00275,,,,Soll [166] ∧[668],"[166] Wenn vorhanden + [668] Hinweis: Dieses Segment wird nach Abschluss der Einführung der Lokationsbündelstruktur zum 01.10.2025 aus der UTILMD entfernt" + 478,Referenz auf die ID der vorgelagerten Messlokation,SG8,RFF,1153,00275,Z34,,vorgelagerteMesslokation,X, + 479,Referenz auf die ID der vorgelagerten Messlokation,SG8,RFF,1154,00275,,,ID einer Lokation,X [951],[951] Format: Zählpunktbezeichnung + 480,Referenz auf die der Technischen Ressource zugeordneten Marktlokation ,SG8,RFF,,00276,,,,Muss [668],[668] Hinweis: Dieses Segment wird nach Abschluss der Einführung der Lokationsbündelstruktur zum 01.10.2025 aus der UTILMD entfernt + 481,Referenz auf die der Technischen Ressource zugeordneten Marktlokation ,SG8,RFF,1153,00276,Z16,,zugeordneteMarktlokation,X, + 482,Referenz auf die der Technischen Ressource zugeordneten Marktlokation ,SG8,RFF,1154,00276,,,ID der Marktlokation,X [950],[950] Format: Marktlokations-ID + 483,Referenz auf die der Technischen Ressource zugeordneten Steuerbaren Ressource,SG8,RFF,,00277,,,,Soll [166] ∧[699],"[166] Wenn vorhanden + [699] Hinweis: Es ist die ID der Steuerbare Ressource zu nennen" + 484,Referenz auf die der Technischen Ressource zugeordneten Steuerbaren Ressource,SG8,RFF,1153,00277,Z38,,Steuerbare Ressource,X, + 485,Referenz auf die der Technischen Ressource zugeordneten Steuerbaren Ressource,SG8,RFF,1154,00277,,,ID der Steuerbaren Ressource,X [961],[961] Format: SR-ID + 486,Referenz auf die der Technischen Ressource zugeordneten Netzlokation,SG8,RFF,,00278,,,,Soll [166] ∧[700],"[166] Wenn vorhanden + [700] Hinweis: Es ist die ID der Netzlokation zu nennen über die die Technische Ressource gesteuert wird" + 487,Referenz auf die der Technischen Ressource zugeordneten Netzlokation,SG8,RFF,1153,00278,Z32,,Netzlokation,X, + 488,Referenz auf die der Technischen Ressource zugeordneten Netzlokation,SG8,RFF,1154,00278,,,ID der Netzlokation,X [960],[960] Format: Netzlokations-ID + 489,Nennleistung (Aufnahme),SG9,,,,,,,Muss ([446]∧ ([465] ∨[466]) ∧[467] ∧([468] ⊻([469] ∧[470]))) ⊻[448]Soll [165],"[165] Wenn bekannt + [446] Wenn in derselben SG8 das CCI+Z17 (Stromverbrauchsart) vorhanden + [448] Wenn in derselben SG8 das CCI+Z56 (Speicher) vorhanden + [465] Wenn in derselben SG8 SEQ+Z52 (Daten der Technischen Ressource) das RFF+Z38 (Referenz auf die der Technischen Ressource zugeordnete Steuerbare Ressource) vorhanden ist + [466] Wenn in derselben SG8 SEQ+Z52 (Daten der Technischen Ressource) das RFF+Z32 (Referenz auf die der Technischen Ressource zugeordneten Netzlokation) vorhanden ist + [467] Wenn in derselben SG8 SEQ+Z52 (Daten der Technischen Ressource) das CAV+ZG8 (Technischen Ressource" + 490,Nennleistung (Aufnahme),SG9,QTY,,00279,,,,Muss, + 491,Nennleistung (Aufnahme),SG9,QTY,6063,00279,Z43,,Nennleistung(Aufnahme),X, + 492,Nennleistung (Aufnahme),SG9,QTY,6060,00279,,,Menge,X, + 493,Nennleistung (Aufnahme),SG9,QTY,6411,00279,KWT,,Kilowatt,X, + 494,Nennleistung (Abgabe),SG9,,,,,,,Muss [448],[448] Wenn in derselben SG8 das CCI+Z56 (Speicher) vorhanden + 495,Nennleistung (Abgabe),SG9,QTY,,00280,,,,Muss, + 496,Nennleistung (Abgabe),SG9,QTY,6063,00280,Z44,,Nennleistung (Abgabe),X, + 497,Nennleistung (Abgabe),SG9,QTY,6060,00280,,,Menge,X, + 498,Nennleistung (Abgabe),SG9,QTY,6411,00280,KWT,,Kilowatt,X, + 499,Speicherkapazität,SG9,,,,,,,Muss [448],[448] Wenn in derselben SG8 das CCI+Z56 (Speicher) vorhanden + 500,Speicherkapazität,SG9,QTY,,00281,,,,Muss, + 501,Speicherkapazität,SG9,QTY,6063,00281,Z42,,Speicherkapazität,X, + 502,Speicherkapazität,SG9,QTY,6060,00281,,,Menge,X, + 503,Speicherkapazität,SG9,QTY,6411,00281,KWH,,Kilowattstunde,X, + 504,Art und Nutzung der Technischen Ressource,SG10,,,,,,,Muss, + 505,Art und Nutzung der Technischen Ressource,SG10,CCI,,00282,,,,Muss, + 506,Art und Nutzung der Technischen Ressource,SG10,CCI,7059,00282,Z17,,Stromverbrauchsart,X, + 507,Art und Nutzung der Technischen Ressource,SG10,CCI,7059,,Z56,,Speicher,X, + 508,Verbrauchsart,SG10,CAV,,00283,,,,Muss [446],[446] Wenn in derselben SG8 das CCI+Z17 (Stromverbrauchsart) vorhanden + 509,Verbrauchsart,SG10,CAV,7111,00283,Z64,,Kraft/Licht,X [1P0..1], + 510,Verbrauchsart,SG10,CAV,7111,,Z65,,Wärme,X [1P0..1], + 511,Verbrauchsart,SG10,CAV,7111,,ZE5,,E-Mobilität,X [1P0..1], + 512,Verbrauchsart,SG10,CAV,7111,,ZA8,,Straßenbeleuchtung,X [1P0..1], + 513,Wärmenutzung,SG10,CAV,,00284,,,,Muss [239],[239] Wenn in derselben SG10 das CCI+Z17 (Stromverbrauchsart) im CAV+Z65 (Wärme) vorhanden + 514,Wärmenutzung,SG10,CAV,7111,00284,Z56,,Speicherheizung,X, + 515,Wärmenutzung,SG10,CAV,7111,,Z57,,Wärmepumpe,X, + 516,Wärmenutzung,SG10,CAV,7111,,Z61,,Direktheizung,X, + 517,Art der E-Mobilität,SG10,CAV,,00285,,,,Muss [95],[95] Wenn in derselben SG10 das CCI+Z17 (Stromverbrauchsart) CAV+ZE5 (E-Mobilität) vorhanden + 518,Art der E-Mobilität,SG10,CAV,7111,00285,ZE6,,Wallbox,X, + 519,Art der E-Mobilität,SG10,CAV,7111,,Z87,,E-Mobilitätsladesäule,X, + 520,Art der E-Mobilität,SG10,CAV,7111,,ZE7,,Ladepark,X, + 521,Speicherart,SG10,CAV,,00287,,,,Muss [448],[448] Wenn in derselben SG8 das CCI+Z56 (Speicher) vorhanden + 522,Speicherart,SG10,CAV,7111,00287,ZF7,,Wasserstoffspeicher,X, + 523,Speicherart,SG10,CAV,7111,,ZF8,,Pumpspeicher,X, + 524,Speicherart,SG10,CAV,7111,,ZF9,,Batteriespeicher,X, + 525,Speicherart,SG10,CAV,7111,,ZG6,,Sonstige Speicherart,X, + 526,Kategorie der verbrauchenden Technischen Ressource,SG10,CAV,,00288,,,,Muss [446]⊻ [448],[446] Wenn in derselben SG8 das CCI+Z17 (Stromverbrauchsart) vorhanden + 527,Kategorie der verbrauchenden Technischen Ressource,SG10,CAV,7111,00288,ZG8,,Technischen Ressourcefällt unter § 14a EnWG,X, + 528,Kategorie der verbrauchenden Technischen Ressource,SG10,CAV,7111,,ZG9,,Technischen Ressourcefällt nicht unter § 14aEnWG,X, + 529,Inbetriebsetzungsdatum der verbrauchenden Technischen Ressource nach § 14a EnWG,SG10,CAV,,00289,,,,Muss [461],[461] Wenn in derselben SG10 das CCI+Z17 (Stromverbrauchsart) im CAV+ZG8 (Technischen Ressource fällt unter § 14a EnWG) vorhanden + 530,Inbetriebsetzungsdatum der verbrauchenden Technischen Ressource nach § 14a EnWG,SG10,CAV,7111,00289,ZH0,,Inbetriebsetzung der TRnach 2023,X, + 531,Inbetriebsetzungsdatum der verbrauchenden Technischen Ressource nach § 14a EnWG,SG10,CAV,7111,,ZH1,,Inbetriebsetzung der TRvor 2024,X, + 532,Einordnung der verbrauchenden Technischen Ressource nach § 14a EnWG mit Inbetriebsetzung vor 2024,SG10,CAV,,00290,,,,Muss [462],[462] Wenn in derselben SG10 das CCI+Z17 (Stromverbrauchsart) im CAV+ZH1 (Inbetriebsetzung der TR vor 2024) vorhanden + 533,Einordnung der verbrauchenden Technischen Ressource nach § 14a EnWG mit Inbetriebsetzung vor 2024,SG10,CAV,7111,00290,ZH2,,Wechselmöglichkeit indas § 14a EnWG-Modellgem. Festlegung BK6-22-300 einmalig nochmöglich,X, + 534,Einordnung der verbrauchenden Technischen Ressource nach § 14a EnWG mit Inbetriebsetzung vor 2024,SG10,CAV,7111,,ZH3,,Wechselmöglichkeit indas § 14a EnWG-Modellgem. Festlegung BK6-22-300 nicht möglich,X, + 535,Einordnung der verbrauchenden Technischen Ressource nach § 14a EnWG mit Inbetriebsetzung vor 2024,SG10,CAV,7111,,ZH4,,Befristet im alten § 14aEnWG-Modell bis 2028ohneWechselmöglichkeit,X, + 536,Einordnung der verbrauchenden Technischen Ressource nach § 14a EnWG mit Inbetriebsetzung vor 2024,SG10,CAV,7111,,ZH5,,Wechsel in das § 14aEnWG-Modell gem.Festlegung BK6-22-300wurde durchgeführt,X, + 537,Information zu weiteren technischen Einrichtungen,SG10,,,,,,,Muss [446]∧ [467],"[446] Wenn in derselben SG8 das CCI+Z17 (Stromverbrauchsart) vorhanden + [467] Wenn in derselben SG8 SEQ+Z52 (Daten der Technischen Ressource) das CAV+ZG8 (Technischen Ressource fällt unter §14a EnWG) vorhanden ist" + 538,Information zu weiteren technischen Einrichtungen,SG10,CCI,,00291,,,,Muss, + 539,Information zu weiteren technischen Einrichtungen,SG10,CCI,7059,00291,Z63,,Information zu weiterentechnischenEinrichtungen,X, + 540,Information zu weiteren technischen Einrichtungen,SG10,CAV,,00292,,,,Muss, + 541,Information zu weiteren technischen Einrichtungen,SG10,CAV,7111,00292,ZH7,,Weitere technischeEinrichtungen vorhanden,X, + 542,Information zu weiteren technischen Einrichtungen,SG10,CAV,7111,,ZH8,,Keine weitere technischeEinrichtung vorhanden,X, + 543,Daten der Steuerbaren Ressource,SG8,,,,,,,Muss [205]∧ [2358],"[205] Wenn SG5 LOC+Z19 (Steuerbare Ressource) vorhanden + [2358] Je SG5 LOC+Z19 (Steuerbare Ressource) ist genau einmal die Segmentgruppe anzugeben" + 544,Daten der Steuerbaren Ressource,SG8,SEQ,,00293,,,,Muss, + 545,Daten der Steuerbaren Ressource,SG8,SEQ,1229,00293,Z62,,Daten der SteuerbarenRessource,X, + 546,Referenz auf die ID der Steuerbaren Ressource,SG8,RFF,,00294,,,,Muss, + 547,Referenz auf die ID der Steuerbaren Ressource,SG8,RFF,1153,00294,Z38,,Steuerbare Ressource,X, + 548,Referenz auf die ID der Steuerbaren Ressource,SG8,RFF,1154,00294,,,ID der Steuerbaren Ressource,X [961],[961] Format: SR-ID + 549,Steuerkanal,SG10,,,,,,,Muss, + 550,Steuerkanal,SG10,CCI,,00295,,,,Muss, + 551,Steuerkanal,SG10,CCI,7059,00295,Z49,,Steuerkanal,X, + 552,Leistungsbeschreibung des Steuerkanals,SG10,CAV,,00296,,,,Muss, + 553,Leistungsbeschreibung des Steuerkanals,SG10,CAV,7111,00296,ZF2,,Leistungsbeschreibungdes Steuerkanals,X, + 554,Leistungsbeschreibung des Steuerkanals,SG10,CAV,1131,00296,Z14,,An/Aus,X, + 555,Leistungsbeschreibung des Steuerkanals,SG10,CAV,1131,,Z15,,Gestuft,X, + 556,Zugeordnete Marktpartner,SG10,,,,,,,Muss, + 557,Zugeordnete Marktpartner,SG10,CCI,,00297,,,,Muss, + 558,Zugeordnete Marktpartner,SG10,CCI,7037,00297,ZB3,,ZugeordneterMarktpartner,X, + 559,Messstellenbetreiber,SG10,CAV,,00298,,,,Muss, + 560,Messstellenbetreiber,SG10,CAV,7111,00298,Z91,,MSB,X, + 561,Messstellenbetreiber,SG10,CAV,1131,00298,,,MP-ID,X, + 562,Messstellenbetreiber,SG10,CAV,7110,00298,Z39,,GrundzuständigerMessstellenbetreiber,X, + 563,Messstellenbetreiber,SG10,CAV,7110,,Z40,,WettbewerblicherMessstellenbetreiber,X, + 564,Messstellenbetreiber,SG10,CAV,7110,,Z41,,Auffangmessstellenbetreiber,X, + 565,Produkt-Daten der Steuerbaren Ressource,SG8,,,,,,,Soll [166] ∧[205],"[166] Wenn vorhanden + [205] Wenn SG5 LOC+Z19 (Steuerbare Ressource) vorhanden" + 566,Produkt-Daten der Steuerbaren Ressource,SG8,SEQ,,00299,,,,Muss, + 567,Produkt-Daten der Steuerbaren Ressource,SG8,SEQ,1229,00299,Z61,,Produkt-Daten derSteuerbaren Ressource,X, + 568,Referenz auf die ID der Steuerbaren Ressource,SG8,RFF,,00300,,,,Muss, + 569,Referenz auf die ID der Steuerbaren Ressource,SG8,RFF,1153,00300,Z38,,Steuerbare Ressource,X, + 570,Referenz auf die ID der Steuerbaren Ressource,SG8,RFF,1154,00300,,,ID einer Steuerbaren Ressource,X [961],[961] Format: SR-ID + 571,Produkt-Daten der Steuerbaren Ressource,SG8,PIA,,00301,,,,Muss, + 572,Produkt-Daten der Steuerbaren Ressource,SG8,PIA,4347,00301,5,,Produktidentifikation,X, + 573,Produkt-Daten der Steuerbaren Ressource,SG8,PIA,7140,00301,,,Konfigurationsprodukt-Code,X, + 574,Produkt-Daten der Steuerbaren Ressource,SG8,PIA,7143,00301,Z12,,Konfigurationsprodukt,X, + 575,Zugeordnete Definition,SG10,,,,,,,Muss, + 576,Zugeordnete Definition,SG10,CCI,,00302,,,,Muss, + 577,Zugeordnete Definition,SG10,CCI,7059,00302,Z52,,Code der,X, + 578,Zugeordnete Definition,SG10,CCI,7037,00302,,,Code der Definition,X, + 579,Auftraggebender Marktpartner,SG10,,,,,,,Muss, + 580,Auftraggebender Marktpartner,SG10,CCI,,00303,,,,Muss, + 581,Auftraggebender Marktpartner,SG10,CCI,7037,00303,ZB3,,ZugeordneterMarktpartner,X, + 582,Auftraggebender Marktpartner,SG10,CAV,,00304,,,,Muss, + 583,Auftraggebender Marktpartner,SG10,CAV,7111,00304,Z88,,NB,X, + 584,Auftraggebender Marktpartner,SG10,CAV,7111,,Z89,,LF,X, + 585,Auftraggebender Marktpartner,SG10,CAV,1131,00304,,,MP-ID,X, + 586,Produkt-Daten für Marktrolle relevant,SG10,,,,,,,Muss, + 587,Produkt-Daten für Marktrolle relevant,SG10,CCI,,00305,,,,Muss, + 588,Produkt-Daten für Marktrolle relevant,SG10,CCI,7037,00305,ZA7,,LF,X, + 589,Daten der Messlokation,SG8,,,,,,,Muss [2284],[2284] Für jede Messlokations-ID im SG5 LOC+Z17 (Messlokation) DE3225 genau einmal anzugeben + 590,Daten der Messlokation,SG8,SEQ,,00306,,,,Muss, + 591,Daten der Messlokation,SG8,SEQ,1229,00306,Z18,,Daten der Messlokation,X, + 592,Referenz auf die ID der Messlokation,SG8,RFF,,00307,,,,Muss, + 593,Referenz auf die ID der Messlokation,SG8,RFF,1153,00307,Z19,,Messlokation,X, + 594,Referenz auf die ID der Messlokation,SG8,RFF,1154,00307,,,ID der Messlokation,X [951],[951] Format: Zählpunktbezeichnung + 595,Abrechnung des Messstellenbetriebs über NNE für kME,SG8,RFF,,00309,,,,Muss [235],"[235] Wenn das RFF+Z19 (Messlokation) aus dieser SG8 auf das gleiche SG5 LOC+Z17 (Messlokation), wie ein RFF+Z19 (Messlokation) aus einer SG8 SEQ+Z03 (Zähleinrichtungsdaten)," + 596,Abrechnung des Messstellenbetriebs über NNE für kME,SG8,RFF,1153,00309,Z05,,Abrechnung desMessstellenbetriebs überNNE für kME,X, + 597,Abrechnung des Messstellenbetriebs über NNE für kME,SG8,RFF,1154,00309,,,Abrechnung über NNE (Ja/Nein),X, + 598,Zugeordnete Marktpartner,SG10,,,,,,,Muss, + 599,Zugeordnete Marktpartner,SG10,CCI,,00310,,,,Muss, + 600,Zugeordnete Marktpartner,SG10,CCI,7037,00310,ZB3,,ZugeordneterMarktpartner,X, + 601,Messstellenbetreiber,SG10,CAV,,00311,,,,Muss, + 602,Messstellenbetreiber,SG10,CAV,7111,00311,Z91,,MSB,X, + 603,Messstellenbetreiber,SG10,CAV,1131,00311,,,MP-ID,X, + 604,Messstellenbetreiber,SG10,CAV,7110,00311,Z19,,Auf vertraglicherGrundlage gegenüberAnschlussnutzer /Anschlussnehmer,X, + 605,Messstellenbetreiber,SG10,CAV,7110,,Z20,,In der Ausübung derWeiterverpflichtungdurch den gMSB,X, + 606,Messstellenbetreiber,SG10,CAV,7110,00311,Z39,,GrundzuständigerMessstellenbetreiber,X, + 607,Messstellenbetreiber,SG10,CAV,7110,,Z40,,WettbewerblicherMessstellenbetreiber,X, + 608,Messstellenbetreiber,SG10,CAV,7110,,Z41,,Auffangmessstellenbetreiber,X, + 609,Grundzuständiger Messstellenbetreiber,SG10,CAV,,00312,,,,Muss, + 610,Grundzuständiger Messstellenbetreiber,SG10,CAV,7111,00312,ZF0,,gMSB,X, + 611,Grundzuständiger Messstellenbetreiber,SG10,CAV,1131,00312,,,MP-ID,X, + 612,Spannungsebene der Messlokation,SG10,,,,,,,Muss, + 613,Spannungsebene der Messlokation,SG10,CCI,,00314,,,,Muss, + 614,Spannungsebene der Messlokation,SG10,CCI,7037,00314,E04,,Spannungsebene derMesslokation,X, + 615,Spannungsebene der Messlokation,SG10,CAV,,00315,,,,Muss, + 616,Spannungsebene der Messlokation,SG10,CAV,7111,00315,E03,,Höchstspannung,X, + 617,Spannungsebene der Messlokation,SG10,CAV,7111,,E04,,Hochspannung,X, + 618,Spannungsebene der Messlokation,SG10,CAV,7111,,E05,,Mittelspannung,X, + 619,Spannungsebene der Messlokation,SG10,CAV,7111,,E06,,Niederspannung,X, + 620,Zähleinrichtungsdaten,SG8,,,,,,,Muss [2286],[2286] Für jede SEQ+Z18 (Daten der Messlokation) mindestens einmal anzugeben + 621,Zähleinrichtungsdaten,SG8,SEQ,,00326,,,,Muss, + 622,Zähleinrichtungsdaten,SG8,SEQ,1229,00326,Z03,,Zähleinrichtungsdaten,X, + 623,Referenz auf die ID einer Messlokation,SG8,RFF,,00327,,,,Muss, + 624,Referenz auf die ID einer Messlokation,SG8,RFF,1153,00327,Z19,,Messlokation,X, + 625,Referenz auf die ID einer Messlokation,SG8,RFF,1154,00327,,,ID einer Messlokation,X [951],[951] Format: Zählpunktbezeichnung + 626,Referenz auf das Smartmeter-Gateway,SG8,RFF,,00328,,,,Soll [166] ∧[215],"[166] Wenn vorhanden + [215] Wenn in derselben SG8 SEQ+Z03 (Zähleinrichtungsdaten) SG10 CCI+++E13 CAV+MME (Zählertyp: mME) vorhanden" + 627,Referenz auf das Smartmeter-Gateway,SG8,RFF,1153,00328,Z14,,Smartmeter-Gateway,X, + 628,Referenz auf das Smartmeter-Gateway,SG8,RFF,1154,00328,,,Identifikation / Nummer desSmartmeter-Gateways,X, + 629,Zählertyp,SG10,,,,,,,Muss, + 630,Zählertyp,SG10,CCI,,00329,,,,Muss, + 631,Zählertyp,SG10,CCI,7037,00329,E13,,Zählertyp,X, + 632,Zählertyp,SG10,CAV,,00330,,,,Muss, + 633,Zählertyp,SG10,CAV,7111,00330,AHZ,,analoger Haushaltszähler(Drehstrom),X, + 634,Zählertyp,SG10,CAV,7111,,WSZ,,analogerWechselstromzähler,X, + 635,Zählertyp,SG10,CAV,7111,,LAZ,,Lastgangzähler,X, + 636,Zählertyp,SG10,CAV,7111,,MAZ,,Maximumzähler,X, + 637,Zählertyp,SG10,CAV,7111,,MME,,moderneMesseinrichtung nachMsbG,X, + 638,Zählertyp,SG10,CAV,7111,,EHZ,,elektronischerHaushaltszähler,X , + 639,Zählertyp,SG10,CAV,7111,,IVA,,Individuelle Abstimmung(Sonderausstattung),X, + 640,Zählertyp,SG10,CAV,7110,00330,Z01,,EDL40,X [136], + 641,Zählertyp,SG10,CAV,7110,,Z02,,EDL21,X [136], + 642,Zählertyp,SG10,CAV,7110,,Z03,,sonstiger EHZ,X [136],[136] Wenn SG10 CCI+++E13 (Zählertyp) CAV+EHZ (elektronischer + 643,Identifikation / Nummer des Gerätes,SG10,CAV,,00331,,,,Muss, + 644,Identifikation / Nummer des Gerätes,SG10,CAV,7111,00331,Z30,,Gerätenummer,X, + 645,Identifikation / Nummer des Gerätes,SG10,CAV,7110,00331,,,Gerätenummer,X, + 646,Registeranzahl,SG10,CAV,,00332,,,,Muss [139],[139] Wenn SG10 CAV+IVA (Individuelle Abstimmung) nicht vorhanden + 647,Registeranzahl,SG10,CAV,7111,00332,ETZ,,Eintarif,X, + 648,Registeranzahl,SG10,CAV,7111,,ZTZ,,Zweitarif,X, + 649,Registeranzahl,SG10,CAV,7111,,NTZ,,Mehrtarif,X, + 650,Energierichtung,SG10,CAV,,00333,,,,Muss, + 651,Energierichtung,SG10,CAV,7111,00333,ERZ,,Einrichtungszähler,X, + 652,Energierichtung,SG10,CAV,7111,,ZRZ,,Zweirichtungszähler,X, + 653,Fernschaltung der Zähleinrichtung,SG10,CAV,,00334,,,,Muss, + 654,Fernschaltung der Zähleinrichtung,SG10,CAV,7111,00334,Z58,,Fernschaltung derZähleinrichtung,X, + 655,Fernschaltung der Zähleinrichtung,SG10,CAV,7110,00334,Z06,,vorhanden,X, + 656,Fernschaltung der Zähleinrichtung,SG10,CAV,7110,,Z07,,nicht vorhanden,X, + 657,Messwerterfassung an der Zähleinrichtung,SG10,,,,,,,Muss [316],[316] Wenn in derselben SG8 das RFF+Z14 (Smartmeter-Gateway) nicht vorhanden + 658,Messwerterfassung an der Zähleinrichtung,SG10,CCI,,00337,,,,Muss, + 659,Messwerterfassung an der Zähleinrichtung,SG10,CCI,7037,00337,E12,,Messwerterfassung ander Zähleinrichtung,X, + 660,Messwerterfassung an der Zähleinrichtung,SG10,CAV,,00338,,,,Muss, + 661,Messwerterfassung an der Zähleinrichtung,SG10,CAV,7111,00338,AMR,,fernauslesbare Zähler,X, + 662,Messwerterfassung an der Zähleinrichtung,SG10,CAV,7111,,MMR,,manuell ausgelesene,X, + 663,OBIS-Daten der Zähleinrichtung / Smartmeter-Gateway,SG8,,,,,,,Muss([2287] ∧[121]) ∨[2350],"[121] Wenn in dem SEQ+Z03 (Zähleinrichtungsdaten) das SG8 RFF+Z14 (Referenz auf das Smartmeter-Gateway) nicht vorhanden + [2287] Für jede SEQ+Z03 (Zähleinrichtungsdaten) mindestens einmal anzugeben + [2350] Für jedes SMGW das im SEQ+Z13 (Smartmeter-Gateway) SG10 CCI+++Z75 CAV+Z30 (Gerätenummer) genannt ist, mindestens einmal je SEQ+Z03 (Zähleinrichtungsdaten) das mit SG8 RFF+Z14 (Referenz auf das Smartmeter-Gateway) auf das SMGW referenziert" + 664,OBIS-Daten der Zähleinrichtung / Smartmeter-Gateway,SG8,SEQ,,00339,,,,Muss, + 665,OBIS-Daten der Zähleinrichtung / Smartmeter-Gateway,SG8,SEQ,1229,00339,Z20,,OBIS-Daten derZähleinrichtung,X, + 666,Referenz auf die Gerätenummer,SG8,RFF,,00340,,,,Muss [665],[665] Hinweis: Wenn ein Zähler mit einem SMGW parametriert ist werden an dem Zähler keine OBIS-Kennzahlen angegeben Hier gibt es nur OBIS Kennzahlen vom SMGW + 667,Referenz auf die Gerätenummer,SG8,RFF,1153,00340,MG,,Gerätenummer desZählers,X [441], + 668,Referenz auf die Gerätenummer,SG8,RFF,1153,,Z14,,Smartmeter-Gateway,X,[441] Wenn im SG8+SEQ+Z03 (Zähleinrichtungsdaten) für die in diesem RFF DE1154 genannte Gerätenummer eines Zählers das RFF+Z14 (Referenz auf das Smartmeter-Gateway) + 669,Referenz auf die Gerätenummer,SG8,RFF,1154,00340,,,Gerätenummer,X, + 670,Referenz auf die ID einer Messlokation,SG8,RFF,,00341,,,,Muss, + 671,Referenz auf die ID einer Messlokation,SG8,RFF,1153,00341,Z19,,Messlokation,X, + 672,Referenz auf die ID einer Messlokation,SG8,RFF,1154,00341,,,ID einer Messlokation,X [951],[951] Format: Zählpunktbezeichnung + 673,Konfigurations-ID,SG8,RFF,,00343,,,,Muss [96] ∧[402] ∧[420] ∧[661]Soll [166] ∧[80] ∧ [402]∧ [420],"[80] Wenn SG4 STS+7++Z37 (Transaktionsgrund: EoG aus Einzug in Neuanlage) vorhanden + [96] Wenn SG4 STS+7++Z37 (Transaktionsgrund: EoG aus Einzug in Neuanlage) nicht vorhanden + [166] Wenn vorhanden + [402] Wenn in derselben SG8 SEQ+Z20 (OBIS- Daten der Zähleinrichtung / Smartmeter-Gateway) eine OBIS-Kennzahl der Werteart ""Zählerstand"" im PIA+5 vorhanden + [420] Wenn in dieser SG8 das RFF+Z14 (Smartmeter-Gateway) vorhanden ist + [661] Hinweis: Ist dem NB bereits die ab dem Lieferbeginn zu verwendende Konfuigurations-ID bekannt, teilt er diese bereits hier mit. Liegt diese noch nicht vor, teilt der NB die aktuell verwendete Konfigurations-ID mit und veranlasst beim MSB eine Konfigurationsänderung, welche nach" + 674,Konfigurations-ID,SG8,RFF,1153,00343,AGK,,Anwendungsreferenznummer,X, + 675,Konfigurations-ID,SG8,RFF,1154,00343,,,"Referenz, Identifikation",X, + 676,OBIS-Kennzahl der Zähleinrichtung / Smartmeter-Gateway,SG8,PIA,,00344,,,,Muss, + 677,OBIS-Kennzahl der Zähleinrichtung / Smartmeter-Gateway,SG8,PIA,4347,00344,5,,Produktidentifikation,X, + 678,OBIS-Kennzahl der Zähleinrichtung / Smartmeter-Gateway,SG8,PIA,7140,00344,,,OBIS-Kennzahl derZähleinrichtung,X [323],"[323] Es sind alle OBIS- Kennzahlen gem. EDI@Energy Codeliste der OBIS-Kennzahlen und Medien für den deutschen Energiemarkt Kap. 3. anzugeben, welche an der Zähleinrichtung genutzt werden. Der Mindestumfang der OBIS-Kennzahlen ergibt sich aus den genannten Messprodukt-Codes dem Kap. 5.1 des Dokumentes ""Codeliste der Konfigurationen""" + 679,OBIS-Kennzahl der Zähleinrichtung / Smartmeter-Gateway,SG8,PIA,7143,00344,SRW,,OBIS-Kennzahl,X, + 680,Wertegranularität,SG10,,,,,,,Muss [256],[256] Wenn in derselben SG8 SEQ+Z20 (OBIS- Daten der Zähleinrichtung / Smartmeter-Gateway) das PIA+5+1-b?:1.8.e / 1-b?:2.8.e vorhanden + 681,Wertegranularität,SG10,CCI,,00345,,,,Muss, + 682,Wertegranularität,SG10,CCI,7037,00345,ZE4,,Wertegranularität,X, + 683,Wertegranularität,SG10,CAV,,00346,,,,Muss, + 684,Wertegranularität,SG10,CAV,7111,00346,ZD9,,Jährlich,X, + 685,Wertegranularität,SG10,CAV,7111,,ZE8,,Halbjährlich,X, + 686,Wertegranularität,SG10,CAV,7111,,ZE9,,Quartalsweise,X, + 687,Wertegranularität,SG10,CAV,7111,,ZB7,,Monatlich,X, + 688,Zugeordnete Zählzeitdefinition,SG10,,,,,,,Muss [389]∧ [391],"[389] Wenn mehr als eine SG8 SEQ+Z20 (OBIS-Daten der Zähleinrichtung / Smartmeter-Gateway), die mit dem RFF+MG/ Z14 (Referenz auf die Gerätenummer) auf die gleiche Gerätenummer referenziert, mit einer OBIS-Kennzahl der Werteart ""Zählerstand"" im PIA+5 vorhanden + [391] Wenn in derselben SG8 SEQ+Z20 (OBIS Daten der Zähleinrichtung / Smartmeter-Gateway) eine OBIS-Kennzahl für Zählerstand im PIA+5 vorhanden und es sich lt. Codeliste OBIS um eine OBIS mit zugeordneter Zählzeit handelt (Tarif: e = 1 .. 62)" + 689,Zugeordnete Zählzeitdefinition,SG10,CCI,,00347,,,,Muss, + 690,Zugeordnete Zählzeitdefinition,SG10,CCI,7059,00347,Z39,,Code derZählzeitdefinition,X, + 691,Zugeordnete Zählzeitdefinition,SG10,CCI,7037,00347,,,Code der Zählzeitdefinition,X, + 692,Zugeordnetes Zählzeitregister ,SG10,,,,,,,Muss [421],[421] Wenn in dieser SG8 das SG10 CCI+Z39 (Zugeordnete Zählzeitdefinition) vorhanden ist + 693,Zugeordnetes Zählzeitregister ,SG10,CCI,,00348,,,,Muss, + 694,Zugeordnetes Zählzeitregister ,SG10,CCI,7059,00348,Z38,,Code desZählzeitregisters,X, + 695,Zugeordnetes Zählzeitregister ,SG10,CCI,7037,00348,,,Code des Zählzeitregisters,X, + 696,Vor- und Nachkommastellen des Zählwerks,SG10,,,,,,,Muss [273],[273] Wenn in derselben SG8 SEQ+Z20 (OBIS- Daten der Zähleinrichtung / Smartmeter-Gateway) das PIA+5+1-b?:1.8.e / 1-b?:2.8.e / 1-b?:3.8.e / 1-b?:4.8.e / 1-b?:5.8.e / 1-b?:6.8.e / 1-b?:7.8.e / 1-b?:8.8.e /  1-b?:1.8.63 + 697,Vor- und Nachkommastellen des Zählwerks,SG10,CCI,,00349,,,,Muss, + 698,Vor- und Nachkommastellen des Zählwerks,SG10,CCI,7059,00349,11,,Produkt,X, + 699,Vor- und Nachkommastellen des Zählwerks,SG10,CCI,7037,00349,Z33,,Vor- undNachkommastellen desZählwerkes,X, + 700,Vor- und Nachkommastellen des Zählwerks,SG10,CAV,,00350,,,,Muss, + 701,Vor- und Nachkommastellen des Zählwerks,SG10,CAV,7110,00350,,,Angabe der Vorkommastelle,X, + 702,Vor- und Nachkommastellen des Zählwerks,SG10,CAV,7110,00350,,,Angabe der Nachkommastelle,X, + 703,Bezeichnung des Zählwerks auf dem Gerät,SG10,,,,,,,Muss [123]∧ [273],"[123] Wenn noch mindestens eine weitere SG8 SEQ+Z20 (OBIS- Daten der Zähleinrichtung Smartmeter-Gateway) mit dem SG8 RFF+MG (Gerätenummer des Zählers) auf die gleiche Identifikation/Nummer des Gerätes referenziert + [273] Wenn in derselben SG8 SEQ+Z20 (OBIS- Daten der Zähleinrichtung / Smartmeter-Gateway) das PIA+5+1-b?:1.8.e / 1-b?:2.8.e / 1-b?:3.8.e / 1-b?:4.8.e / 1-b?:5.8.e / 1-b?:6.8.e / 1-b?:7.8.e / 1-b?:8.8.e /  1-b?:1.8.63 vorhanden" + 704,Bezeichnung des Zählwerks auf dem Gerät,SG10,CCI,,00351,,,,Muss, + 705,Bezeichnung des Zählwerks auf dem Gerät,SG10,CCI,7037,00351,Z63,,Lokale Kennzeichnung zuKontrollzwecken,X, + 706,Bezeichnung des Zählwerks auf dem Gerät,SG10,CCI,7036,00351,,,Bezeichnung des Zählwerks aufdem Gerät,X, + 707,Wandlerdaten,SG8,,,,,,,Soll [130],[130] Wenn an Messlokation vorhanden + 708,Wandlerdaten,SG8,SEQ,,00353,,,,Muss, + 709,Wandlerdaten,SG8,SEQ,1229,00353,Z04,,Wandler-Daten,X, + 710,Referenz auf die Gerätenummer,SG8,RFF,,00354,,,,Muss, + 711,Referenz auf die Gerätenummer,SG8,RFF,1153,00354,MG,,Gerätenummer desZählers,X, + 712,Referenz auf die Gerätenummer,SG8,RFF,1154,00354,,,Gerätenummer,X, + 713,Wandler,SG10,,,,,,,Muss, + 714,Wandler,SG10,CCI,,00355,,,,Muss, + 715,Wandler,SG10,CCI,7037,00355,Z25,,Wandler,X, + 716,Identifikation / Nummer des Gerätes,SG10,CAV,,00356,,,,Muss [2317]⊻ [2318],"[2317] Wenn in derselben SG8 SEQ+Z04 (Wandlerdaten) das SG10 CCI+++Z25 (Wandler) CAV+MIW/ MPW/MUW vorhanden, ist das Segment mindestens zweimal anzugeben + [2318] Wenn in derselben SG8 SEQ+Z04 (Wandlerdaten) das SG10 CCI+++Z25 (Wandler) CAV+MBW (Blockstromwandler) vorhanden, ist das Segment genau einmal anzugeben" + 717,Identifikation / Nummer des Gerätes,SG10,CAV,7111,00356,Z30,,Gerätenummer,X, + 718,Identifikation / Nummer des Gerätes,SG10,CAV,7110,00356,,,Gerätenummer,X, + 719,Wandlertyp und Faktor,SG10,CAV,,00357,,,,Muss, + 720,Wandlertyp und Faktor,SG10,CAV,7111,00357,MIW,,Messwandlersatz Strom,X, + 721,Wandlertyp und Faktor,SG10,CAV,7111,,MPW,,Kombimesswandlersatz(Strom und Spannung),X, + 722,Wandlertyp und Faktor,SG10,CAV,7111,,MBW,,Blockstromwandler,X, + 723,Wandlertyp und Faktor,SG10,CAV,7111,,MUW,,MesswandlersatzSpannung,X, + 724,Wandlertyp und Faktor,SG10,CAV,7110,00357,,,Wandlerfaktor,X [902][141],"[141] Wenn SG10 CAV+MIW/ MPW/ MBW vorhanden + [902] Format: Möglicher Wert: ≥ 0" + 725,Kommunikationseinrichtun gsdaten,SG8,,,,,,,Muss [2119]Soll [130] ,"[130] Wenn an Messlokation vorhanden + [2119] Je SG8 SEQ+Z13" + 726,Kommunikationseinrichtun gsdaten,SG8,SEQ,,00358,,,,Muss, + 727,Kommunikationseinrichtun gsdaten,SG8,SEQ,1229,00358,Z05,,Kommunikationseinrichtungsdaten,X, + 728,Referenz auf die Gerätenummer,SG8,RFF,,00359,,,,Muss, + 729,Referenz auf die Gerätenummer,SG8,RFF,1153,00359,MG,,Gerätenummer desZählers,X, + 730,Referenz auf die Gerätenummer,SG8,RFF,1154,00359,,,Gerätenummer,X, + 731,Kommunikationseinrichtun g,SG10,,,,,,,Muss, + 732,Kommunikationseinrichtun g,SG10,CCI,,00360,,,,Muss, + 733,Kommunikationseinrichtun g,SG10,CCI,7037,00360,Z26,,Kommunikationseinrichtung,X, + 734,Identifikation / Nummer des Gerätes,SG10,CAV,,00361,,,,Muss, + 735,Identifikation / Nummer des Gerätes,SG10,CAV,7111,00361,Z30,,Gerätenummer,X, + 736,Identifikation / Nummer des Gerätes,SG10,CAV,7110,00361,,,Gerätenummer,X, + 737,Kommunikationseinrichtun gstyp,SG10,CAV,,00362,,,,Muss, + 738,Kommunikationseinrichtun gstyp,SG10,CAV,7111,00362,GSM,,GSM/GPRS/UMTS-Kom.-Einr.,X, + 739,Kommunikationseinrichtun gstyp,SG10,CAV,7111,,ETH,,Ethernet-Kom.-Einricht.LAN/WLAN,X, + 740,Kommunikationseinrichtun gstyp,SG10,CAV,7111,,PLC,,PLC-Kom.-Einrichtung,X, + 741,Kommunikationseinrichtun gstyp,SG10,CAV,7111,,PST,,Festnetz-Kom.-Einricht.TAE,X, + 742,Kommunikationseinrichtun gstyp,SG10,CAV,7111,,DSL,,DSL-Kom.Einr.,X, + 743,Kommunikationseinrichtun gstyp,SG10,CAV,7111,,LTE,,LTE-Kom.-Einr.,X, + 744,Daten der technischen Steuereinrichtung,SG8,,,,,,,Soll [130],[130] Wenn an Messlokation vorhanden + 745,Daten der technischen Steuereinrichtung,SG8,SEQ,,00363,,,,Muss, + 746,Daten der technischen Steuereinrichtung,SG8,SEQ,1229,00363,Z06,,Daten der technischenSteuereinrichtung,X, + 747,Referenz auf die Gerätenummer,SG8,RFF,,00364,,,,Muss, + 748,Referenz auf die Gerätenummer,SG8,RFF,1153,00364,MG,,Gerätenummer desZählers,X, + 749,Referenz auf die Gerätenummer,SG8,RFF,1154,00364,,,Gerätenummer,X, + 750,Technische Steuereinrichtung,SG10,,,,,,,Muss, + 751,Technische Steuereinrichtung,SG10,CCI,,00365,,,,Muss, + 752,Technische Steuereinrichtung,SG10,CCI,7037,00365,Z27,,TechnischeSteuereinrichtung,X, + 753,Identifikation / Nummer des Gerätes,SG10,CAV,,00366,,,,Muss, + 754,Identifikation / Nummer des Gerätes,SG10,CAV,7111,00366,Z30,,Gerätenummer,X, + 755,Identifikation / Nummer des Gerätes,SG10,CAV,7110,00366,,,Gerätenummer,X, + 756,Technische Steuereinrichtungstyp,SG10,CAV,,00367,,,,Muss, + 757,Technische Steuereinrichtungstyp,SG10,CAV,7111,00367,RSU,,Rundsteuerempfänger,X, + 758,Technische Steuereinrichtungstyp,SG10,CAV,7111,,TSU,,Tarifschaltuhr,X, + 759,Smartmeter-Gateway,SG8,,,,,,,Soll [130],[130] Wenn an Messlokation vorhanden + 760,Smartmeter-Gateway,SG8,SEQ,,00368,,,,Muss, + 761,Smartmeter-Gateway,SG8,SEQ,1229,00368,Z13,,Smartmeter-Gateway,X, + 762,Smartmeter-Gateway,SG10,,,,,,,Muss, + 763,Smartmeter-Gateway,SG10,CCI,,00369,,,,Muss, + 764,Smartmeter-Gateway,SG10,CCI,7037,00369,Z75,,Smartmeter-Gateway,X, + 765,Identifikation / Nummer des Gerätes,SG10,CAV,,00370,,,,Muss, + 766,Identifikation / Nummer des Gerätes,SG10,CAV,7111,00370,Z30,,Gerätenummer,X, + 767,Identifikation / Nummer des Gerätes,SG10,CAV,7110,00370,,,Gerätenummer,X [952],[952] Format: Gerätenummer nach DIN 43863-5 + 768,Daten der Steuerbox,SG8,,,,,,,Soll [133],[133] Wenn an der übermittelten Marktlokation / Messlokation vorhanden + 769,Daten der Steuerbox,SG8,SEQ,,00371,,,,Muss, + 770,Daten der Steuerbox,SG8,SEQ,1229,00371,Z14,,Steuerbox,X, + 771,Referenz auf das Smartmeter-Gateway,SG8,RFF,,00372,,,,Muss, + 772,Referenz auf das Smartmeter-Gateway,SG8,RFF,1153,00372,Z14,,Smartmeter-Gateway,X, + 773,Referenz auf das Smartmeter-Gateway,SG8,RFF,1154,00372,,,Identifikation / Nummer desSmartmeter-Gateways,X, + 774,Referenz auf die ID der Marktlokation,SG8,RFF,,00373,,,,Muss, + 775,Referenz auf die ID der Marktlokation,SG8,RFF,1153,00373,Z18,,Marktlokation,X, + 776,Referenz auf die ID der Marktlokation,SG8,RFF,1154,00373,,,ID einer Marktlokation,X [950],[950] Format: Marktlokations-ID + 777,Steuerbox,SG10,,,,,,,Muss, + 778,Steuerbox,SG10,CCI,,00374,,,,Muss, + 779,Steuerbox,SG10,CCI,7037,00374,Z76,,Steuerbox,X, + 780,Identifikation / Nummer des Gerätes,SG10,CAV,,00375,,,,Muss, + 781,Identifikation / Nummer des Gerätes,SG10,CAV,7111,00375,Z30,,Gerätenummer,X, + 782,Identifikation / Nummer des Gerätes,SG10,CAV,7110,00375,,,Gerätenummer,X [952],[952] Format: Gerätenummer nach DIN 43863-5 + 783,Profildaten,SG8,,,,,,,Muss [119],[119] Wenn in der SG8 SEQ+Z01 SG10 CCI+++ZA6 (Prognosegrundlage der Marktlokation: Prognose auf Basis von Profilen) CAV+E02 (SLP/SEP) vorhanden + 784,Profildaten,SG8,SEQ,,00376,,,,Muss, + 785,Profildaten,SG8,SEQ,1229,00376,Z21,,Profildaten,X, + 786,Referenz auf die ID der Marktlokation,SG8,RFF,,00378,,,,Muss, + 787,Referenz auf die ID der Marktlokation,SG8,RFF,1153,00378,Z18,,Marktlokation,X, + 788,Referenz auf die ID der Marktlokation,SG8,RFF,1154,00378,,,ID einer Marktlokation,X [950],[950] Format: Marktlokations-ID + 789,Normiertes Profil,SG10,,,,,,,Muss, + 790,Normiertes Profil,SG10,CCI,,00380,,,,Muss, + 791,Normiertes Profil,SG10,CCI,7059,00380,Z02,,Standardlastprofil,X, + 792,Normiertes Profil,SG10,CCI,7037,00380,E01,,synthetisches Verfahren,X, + 793,Normiertes Profil,SG10,CCI,7037,,Z10,,analytisches Verfahren,X [332],[332] Wenn im SG8 SEQ+Z01 (Daten der Marktlokation) das SG10 CCI+6++ZA9 (Aggreg. verantw. ÜNB) nicht + 794,Normiertes Profil,SG10,CAV,,00381,,,,Muss, + 795,Normiertes Profil,SG10,CAV,7111,00381,,,Code des Normierten Profils,X, + 796,Profilschardaten,SG8,,,,,,,Muss [89],[89] Wenn im SG8 SEQ+Z01 (Daten der Marktlokation) das SG10 CCI+++ZA6 (Prognosegrundlage der Marktlokation: Prognose auf Basis von Profilen) CAV+E14 (TLP/TEP) vorhanden + 797,Profilschardaten,SG8,SEQ,,00387,,,,Muss, + 798,Profilschardaten,SG8,SEQ,1229,00387,Z08,,Profilschardaten,X, + 799,Referenz auf die ID der Marktlokation,SG8,RFF,,00389,,,,Muss, + 800,Referenz auf die ID der Marktlokation,SG8,RFF,1153,00389,Z18,,Marktlokation,X, + 801,Referenz auf die ID der Marktlokation,SG8,RFF,1154,00389,,,ID einer Marktlokation,X [950],[950] Format: Marktlokations-ID + 802,Profilschar,SG10,,,,,,,Muss, + 803,Profilschar,SG10,CCI,,00397,,,,Muss, + 804,Profilschar,SG10,CCI,7037,00397,Z12,,Profilschar,X, + 805,Profilschar,SG10,CAV,,00398,,,,Muss, + 806,Profilschar,SG10,CAV,7111,00398,,,Code der Profilschar,X, + 807,Normiertes Profil,SG10,,,,,,,Muss, + 808,Normiertes Profil,SG10,CCI,,00399,,,,Muss, + 809,Normiertes Profil,SG10,CCI,7059,00399,Z03,,tagesparameterabhängiges Lastprofil,X, + 810,Normiertes Profil,SG10,CCI,7037,00399,E01,,synthetisches Verfahren,X, + 811,Normiertes Profil,SG10,CCI,7037,,Z10,,analytisches Verfahren,X, + 812,Normiertes Profil,SG10,CAV,,00400,,,,Muss, + 813,Normiertes Profil,SG10,CAV,7111,00400,,,Code des Normierten Profils,X, + 814,Klimazone / Temperaturmessstelle,SG10,,,,,,,Muss, + 815,Klimazone / Temperaturmessstelle,SG10,CCI,,00403,,,,Muss, + 816,Klimazone / Temperaturmessstelle,SG10,CCI,7059,00403,Z99,,Messstelle des,X, + 817,Klimazone / Temperaturmessstelle,SG10,CCI,7037,00403,,,ID Klimazone /Temperaturmessstelle,X, + 818,Klimazone / Temperaturmessstelle,SG10,CCI,1131,00403,,,Dienstanbieter,X [58],[58] Wenn in diesem CCI das DE3055 mit dem Code 293 vorhanden + 819,Klimazone / Temperaturmessstelle,SG10,CCI,3055,00403,89,,Vergeben vom Händler(hier Netzbetreiber),X, + 820,Klimazone / Temperaturmessstelle,SG10,CCI,3055,,293,,"DE, BDEW(Bundesverband derEnergie- undWasserwirtschaft e.V.)",X, + 821,Daten des Kunden des Lieferanten,SG8,,,,,,,Muss, + 822,Daten des Kunden des Lieferanten,SG8,SEQ,,00515,,,,Muss, + 823,Daten des Kunden des Lieferanten,SG8,SEQ,1229,00515,Z75,,Daten des Kunden desLieferanten,X, + 824,Grundlage zur Verringerung der Umlagen nach EnFG,SG10,,,,,,,Muss, + 825,Grundlage zur Verringerung der Umlagen nach EnFG,SG10,CCI,,00516,,,,Muss, + 826,Grundlage zur Verringerung der Umlagen nach EnFG,SG10,CCI,7059,00516,Z61,,Grundlage zurVerringerung derUmlagen nach EnFG,X, + 827,Grundlage zur Verringerung der Umlagen nach EnFG,SG10,CCI,7037,00516,ZF9,,Kunde erfüllt dieVoraussetzung nachEnFG,X, + 828,Grundlage zur Verringerung der Umlagen nach EnFG,SG10,CCI,7037,,ZG0,,Kunde erfüllt nicht dieVoraussetzung nachEnFG,X, + 829,Grundlage zur Verringerung der Umlagen nach EnFG,SG10,CCI,7037,,ZG1,,"Keine Angabe, daMarktlokation dieVoraussetzung zurVerringerung derUmlagen nach EnFGnicht erfüllt",X, + 830,Grund der Privilegierung nach EnFG,SG10,CAV,,00517,,,,Muss [463],[463] Wenn in derselben SG10 das CCI+Z61++ZF9 (Kunde erfüllt die Voraussetzung nach EnFG) vorhanden + 831,Grund der Privilegierung nach EnFG,SG10,CAV,7111,00517,ZU5,,§ 21 EnFG Stromspeicher,X [1P0..1], + 832,Kunde des Lieferanten,SG12,,,,,,,Muss [203]Soll [165],"[165] Wenn bekannt + [203] Wenn STS+7++E06 / Z39 / ZC6 / ZC7/ ZT6/ ZT7 vorhanden" + 833,Kunde des Lieferanten,SG12,NAD,,00518,,,,Muss, + 834,Kunde des Lieferanten,SG12,NAD,3035,00518,Z09,,Kunde des LF,X, + 835,Kunde des Lieferanten,SG12,NAD,3036,00518,,,Name,X, + 836,Kunde des Lieferanten,SG12,NAD,3045,00518,Z01,,Struktur vonPersonennamen,X, + 837,Kunde des Lieferanten,SG12,NAD,3045,,Z02,,Struktur derFirmenbezeichnung,X, + 838,Referenz auf die ID der Marktlokation,SG12,RFF,,00521,,,,Muss, + 839,Referenz auf die ID der Marktlokation,SG12,RFF,1153,00521,Z18,,Marktlokation,X, + 840,Referenz auf die ID der Marktlokation,SG12,RFF,1154,00521,,,ID der Marktlokation,X [950],[950] Format: Marktlokations-ID + 841,Korrespondenzanschrift des Kunden des Lieferanten,SG12,,,,,,,Muss [213],"[213] Wenn SG12 NAD+Z09 (Kunde des Lieferanten) vorhanden + [559] Hinweis: Die Korrespondenzanschrift" + 842,Korrespondenzanschrift des Kunden des Lieferanten,SG12,NAD,,00522,,,,Muss, + 843,Korrespondenzanschrift des Kunden des Lieferanten,SG12,NAD,3035,00522,Z04,,Korrespondenzanschriftdes Kunden des LF,X, + 844,Korrespondenzanschrift des Kunden des Lieferanten,SG12,NAD,3036,00522,,,Name,X, + 845,Korrespondenzanschrift des Kunden des Lieferanten,SG12,NAD,3045,00522,Z01,,Struktur vonPersonennamen,X, + 846,Korrespondenzanschrift des Kunden des Lieferanten,SG12,NAD,3045,,Z02,,Struktur derFirmenbezeichnung,X, + 847,Korrespondenzanschrift des Kunden des Lieferanten,SG12,NAD,3042,00522,,,Straße und Hausnummer oderPostfach,X, + 848,Korrespondenzanschrift des Kunden des Lieferanten,SG12,NAD,3164,00522,,,Ort,X, + 849,Korrespondenzanschrift des Kunden des Lieferanten,SG12,NAD,3251,00522,,,Postleitzahl,M [268]S [166],"[166] Wenn vorhanden + [268] Wenn der Code im DE3207 in der ""EDI@Energy Codeliste der europäischen Ländercodes"" in der Spalte ""PLZ vorhanden"" ein ""X"" aufgeführt ist" + 850,Korrespondenzanschrift des Kunden des Lieferanten,SG12,NAD,3207,00522,,,"Ländername, Code",X, + 851,Referenz auf die ID der Marktlokation,SG12,RFF,,00523,,,,Muss, + 852,Referenz auf die ID der Marktlokation,SG12,RFF,1153,00523,Z18,,Marktlokation,X, + 853,Referenz auf die ID der Marktlokation,SG12,RFF,1154,00523,,,ID der Marktlokation,X [950],[950] Format: Marktlokations-ID + 854,Kunde des Netzbetreibers,SG12,,,,,,,, + 855,Kunde des Netzbetreibers,SG12,NAD,,00527,,,,, + 856,Kunde des Netzbetreibers,SG12,NAD,3035,00527,Z25,,Kunde des NB,, + 857,Kunde des Netzbetreibers,SG12,NAD,3036,00527,,,Name,, + 858,Kunde des Netzbetreibers,SG12,NAD,3045,00527,Z01,,Struktur vonPersonennamen,, + 859,Kunde des Netzbetreibers,SG12,NAD,3045,,Z02,,Struktur derFirmenbezeichnung,, + 860,Referenz auf die ID der Marktlokation,SG12,RFF,,00528,,,,, + 861,Referenz auf die ID der Marktlokation,SG12,RFF,1153,00528,Z18,,Marktlokation,, + 862,Referenz auf die ID der Marktlokation,SG12,RFF,1154,00528,,,ID der Marktlokation,,[950] Format: Marktlokations-ID + 863,Korrespondenzanschrift des Kunde des Netzbetreibers,SG12,,,,,,,, + 864,Korrespondenzanschrift des Kunde des Netzbetreibers,SG12,NAD,,00529,,,,, + 865,Korrespondenzanschrift des Kunde des Netzbetreibers,SG12,NAD,3035,00529,Z26,,Korrespondenzanschriftdes Kunden des NB,, + 866,Korrespondenzanschrift des Kunde des Netzbetreibers,SG12,NAD,3036,00529,,,Name,, + 867,Korrespondenzanschrift des Kunde des Netzbetreibers,SG12,NAD,3045,00529,Z01,,Struktur vonPersonennamen,, + 868,Korrespondenzanschrift des Kunde des Netzbetreibers,SG12,NAD,3045,,Z02,,Struktur derFirmenbezeichnung,, + 869,Korrespondenzanschrift des Kunde des Netzbetreibers,SG12,NAD,3042,00529,,,Straße und Hausnummer oderPostfach,, + 870,Korrespondenzanschrift des Kunde des Netzbetreibers,SG12,NAD,3164,00529,,,Ort,, + 871,Korrespondenzanschrift des Kunde des Netzbetreibers,SG12,NAD,3251,00529,,,Postleitzahl,,"[166] Wenn vorhanden + [268] Wenn der Code im DE3207 in der ""EDI@Energy Codeliste der europäischen Ländercodes"" in der Spalte ""PLZ vorhanden"" ein ""X"" aufgeführt ist" + 872,Korrespondenzanschrift des Kunde des Netzbetreibers,SG12,NAD,3207,00529,,,"Ländername, Code",, + 873,Referenz auf die ID der Marktlokation,SG12,RFF,,00530,,,,, + 874,Referenz auf die ID der Marktlokation,SG12,RFF,1153,00530,Z18,,Marktlokation,, + 875,Referenz auf die ID der Marktlokation,SG12,RFF,1154,00530,,,ID der Marktlokation,,[950] Format: Marktlokations-ID + 876,Anschlussnehmer,SG12,,,,,,,, + 877,Anschlussnehmer,SG12,NAD,,00531,,,,, + 878,Anschlussnehmer,SG12,NAD,3035,00531,EO,,Anschlussnehmer,, + 879,Anschlussnehmer,SG12,NAD,3036,00531,,,Name,, + 880,Anschlussnehmer,SG12,NAD,3045,00531,Z01,,Struktur vonPersonennamen,, + 881,Anschlussnehmer,SG12,NAD,3045,,Z02,,Struktur derFirmenbezeichnung,, + 882,Anschlussnehmer,SG12,NAD,3042,00531,,,Straße und Hausnummer oderPostfach,, + 883,Anschlussnehmer,SG12,NAD,3164,00531,,,Ort,, + 884,Anschlussnehmer,SG12,NAD,3251,00531,,,Postleitzahl,,"[166] Wenn vorhanden + [268] Wenn der Code im DE3207 in der ""EDI@Energy Codeliste der europäischen Ländercodes"" in der Spalte ""PLZ vorhanden"" ein ""X"" aufgeführt ist" + 885,Anschlussnehmer,SG12,NAD,3207,00531,,,"Ländername, Code",, + 886,Hausverwalter,SG12,,,,,,,, + 887,Hausverwalter,SG12,NAD,,00532,,,,, + 888,Hausverwalter,SG12,NAD,3035,00532,DDO,,Location manager,, + 889,Hausverwalter,SG12,NAD,3036,00532,,,Name,, + 890,Hausverwalter,SG12,NAD,3045,00532,Z01,,Struktur vonPersonennamen,, + 891,Hausverwalter,SG12,NAD,3045,,Z02,,Struktur derFirmenbezeichnung,, + 892,Hausverwalter,SG12,NAD,3042,00532,,,Straße und Hausnummer oderPostfach,, + 893,Hausverwalter,SG12,NAD,3164,00532,,,Ort,, + 894,Hausverwalter,SG12,NAD,3251,00532,,,Postleitzahl,,"[166] Wenn vorhanden + [268] Wenn der Code im DE3207 in der ""EDI@Energy Codeliste der europäischen Ländercodes"" in der Spalte ""PLZ vorhanden"" ein ""X"" aufgeführt ist" + 895,Hausverwalter,SG12,NAD,3207,00532,,,"Ländername, Code",, + 896,Marktlokationsanschrift,SG12,,,,,,,Muss, + 897,Marktlokationsanschrift,SG12,NAD,,00535,,,,Muss, + 898,Marktlokationsanschrift,SG12,NAD,3035,00535,DP,,Lieferanschrift,X, + 899,Marktlokationsanschrift,SG12,NAD,3124,00535,,,Zusatzinformation zurIdentifizierung,K, + 900,Marktlokationsanschrift,SG12,NAD,3042,00535,,,Straße und Hausnummer oderPostfach,S [166]M [212],"[166] Wenn vorhanden + [212] Wenn im selben SG12 NAD DE3124 nicht vorhanden" + 901,Marktlokationsanschrift,SG12,NAD,3164,00535,,,Ort,X, + 902,Marktlokationsanschrift,SG12,NAD,3251,00535,,,Postleitzahl,X, + 903,Marktlokationsanschrift,SG12,NAD,3207,00535,,,"Ländername, Code",X, + 904,Name und Adresse für die Ablesekarte,SG12,,,,,,,Muss [213]∧ [234],"[213] Wenn SG12 NAD+Z09 (Kunde des Lieferanten) vorhanden + [234] Wenn SG10 CCI+++Z83 (Messtechnische Einordnung der Marktlokation) CAV+Z53 (kME/ mME) vorhanden + [560] Hinweis: Die Angabe Name und Adresse für die Ablesekarte wird nicht zur Identifikation genutzt " + 905,Name und Adresse für die Ablesekarte,SG12,NAD,,00538,,,,Muss, + 906,Name und Adresse für die Ablesekarte,SG12,NAD,3035,00538,Z05,,Name und Adresse fürdie Ablesekarte,X, + 907,Name und Adresse für die Ablesekarte,SG12,NAD,3036,00538,,,Name,X, + 908,Name und Adresse für die Ablesekarte,SG12,NAD,3045,00538,Z01,,Struktur vonPersonennamen,X, + 909,Name und Adresse für die Ablesekarte,SG12,NAD,3045,,Z02,,Struktur derFirmenbezeichnung,X, + 910,Name und Adresse für die Ablesekarte,SG12,NAD,3042,00538,,,Straße und Hausnummer oderPostfach,X, + 911,Name und Adresse für die Ablesekarte,SG12,NAD,3164,00538,,,Ort,X, + 912,Name und Adresse für die Ablesekarte,SG12,NAD,3251,00538,,,Postleitzahl,M [268]S [166],"[166] Wenn vorhanden + [268] Wenn der Code im DE3207 in der ""EDI@Energy Codeliste der europäischen Ländercodes"" in der Spalte ""PLZ vorhanden"" ein ""X"" aufgeführt ist" + 913,Name und Adresse für die Ablesekarte,SG12,NAD,3207,00538,,,"Ländername, Code",X, + 914,Referenz auf die ID einer Messlokation,SG12,RFF,,00539,,,,Muss, + 915,Referenz auf die ID einer Messlokation,SG12,RFF,1153,00539,Z19,,Messlokation,X, + 916,Referenz auf die ID einer Messlokation,SG12,RFF,1154,00539,,,ID einer Messlokation,X [951],[951] Format: Zählpunktbezeichnung + 917,Nachrichten-Endesegment,,UNT,,00540,,,,Muss, + 918,Nachrichten-Endesegment,,UNT,0074,00540,,,Anzahl der Segmente in einerNachricht,X, + 919,Nachrichten-Endesegment,,UNT,0062,00540,,,Nachrichten-Referenznummer,X, + + ''' +# --- +# name: TestCli.test_kohlrahbi_cli_with_valid_arguments[55035] + ''' + ,Segmentname,Segmentgruppe,Segment,Datenelement,Segment ID,Code,Qualifier,Beschreibung,Bedingungsausdruck,Bedingung + 0,Nachrichten-Kopfsegment,,UNH,,00003,,,,Muss, + 1,Nachrichten-Kopfsegment,,UNH,0062,00003,,,Nachrichten-Referenznummer,X, + 2,Nachrichten-Kopfsegment,,UNH,0065,00003,UTILMD,,Netzanschluss-Stammdaten,X, + 3,Nachrichten-Kopfsegment,,UNH,0052,00003,D,,Entwurfs-Version,X, + 4,Nachrichten-Kopfsegment,,UNH,0054,00003,11A,,Ausgabe 2011 - A,X, + 5,Nachrichten-Kopfsegment,,UNH,0051,00003,UN,,UN/CEFACT,X, + 6,Nachrichten-Kopfsegment,,UNH,0057,00003,Versionsnummer derzugrundeliegendenBDEW-Nachrichtenbeschreibung,,S1.1a,X, + 7,Beginn der Nachricht,,BGM,,00004,,,,Muss, + 8,Beginn der Nachricht,,BGM,1001,00004,Z14,,Stammdaten der Markt-oder Messlokation,X, + 9,Beginn der Nachricht,,BGM,1004,00004,,,Dokumentennummer,X, + 10,Nachrichtendatum,,DTM,,00005,,,,Muss, + 11,Nachrichtendatum,,DTM,2005,00005,137,,Dokumenten-/Nachrichtendatum/-zeit,X, + 12,Nachrichtendatum,,DTM,2380,00005,,,"Datum oder Uhrzeit oderZeitspanne, Wert",X [931] [494],"[494] Das hier genannte Datum muss der Zeitpunkt sein, zu dem das Dokument erstellt wurde, oder ein Zeitpunkt, der davor liegt + [931] Format: ZZZ = +00" + 13,Nachrichtendatum,,DTM,2379,00005,303,,CCYYMMDDHHMMZZZ,X, + 14,MP-ID Absender,SG2,,,,,,,Muss, + 15,MP-ID Absender,SG2,NAD,,00008,,,,Muss, + 16,MP-ID Absender,SG2,NAD,3035,00008,MS,,Dokumenten-/Nachrichtenausstellerbzw. -absender,X, + 17,MP-ID Absender,SG2,NAD,3039,00008,,,MP-ID,X, + 18,MP-ID Absender,SG2,NAD,3055,00008,9,,GS1,X, + 19,MP-ID Absender,SG2,NAD,3055,,293,,"DE, BDEW(Bundesverband derEnergie- undWasserwirtschaft e.V.)",X, + 20,Ansprechpartner,SG3,,,,,,,Kann, + 21,Ansprechpartner,SG3,CTA,,00009,,,,Muss, + 22,Ansprechpartner,SG3,CTA,3139,00009,IC,,Informationskontakt,X, + 23,Ansprechpartner,SG3,CTA,3412,00009,,,Name vom Ansprechpartner,X, + 24,Kommunikationsverbindung,SG3,COM,,00010,,,,Muss, + 25,Kommunikationsverbindung,SG3,COM,3148,00010,,,Nummer / Adresse,X (([939] [321])∨ ([940] [322]))∧ [514],"[321] Wenn im DE3155 in demselben COM der Code EM vorhanden ist + [322] Wenn im DE3155 in demselben COM der Code TE / FX / AJ / AL vorhanden ist + [514] Hinweis: Es darf nur eine Information im DE3148 übermittelt werden + [939] Format: Die Zeichenkette muss die Zeichen @ und . enthalten + [940] Format: Die Zeichenkette muss mit dem Zeichen + beginnen und danach dürfen nur noch Ziffern folgen" + 26,Kommunikationsverbindung,SG3,COM,3155,00010,EM,,Elektronische Post,X [1P0..1], + 27,Kommunikationsverbindung,SG3,COM,3155,,FX,,Telefax,X [1P0..1], + 28,Kommunikationsverbindung,SG3,COM,3155,,TE,,Telefon,X [1P0..1], + 29,Kommunikationsverbindung,SG3,COM,3155,,AJ,,weiteres Telefon,X [1P0..1], + 30,Kommunikationsverbindung,SG3,COM,3155,,AL,,Handy,X [1P0..1], + 31,MP-ID Empfänger,SG2,,,,,,,Muss, + 32,MP-ID Empfänger,SG2,NAD,,00011,,,,Muss, + 33,MP-ID Empfänger,SG2,NAD,3035,00011,MR,,Nachrichtenempfänger,X, + 34,MP-ID Empfänger,SG2,NAD,3039,00011,,,MP-ID,X,[280] Nur MP-ID aus Sparte Strom + 35,MP-ID Empfänger,SG2,NAD,3055,00011,9,,GS1,X, + 36,MP-ID Empfänger,SG2,NAD,3055,,293,,"DE, BDEW(Bundesverband derEnergie- undWasserwirtschaft e.V.)",X, + 37,Vorgang,SG4,,,,,,,Muss, + 38,Vorgang,SG4,IDE,,00020,,,,Muss, + 39,Vorgang,SG4,IDE,7495,00020,24,,Transaktion,X, + 40,Vorgang,SG4,IDE,7402,00020,,,Vorgangsnummer,X, + 41,Transaktionsgrund,SG4,STS,,00037,,,,Muss [2061],[2061] Segment bzw. Segmentgruppe ist genau einmal je SG4 IDE (Vorgang) anzugeben + 42,Transaktionsgrund,SG4,STS,9015,00037,7,,Transaktionsgrund,X, + 43,Transaktionsgrund,SG4,STS,9013,00037,Z40,,Geschäftsdatenanfrage,X, + 44,Bemerkung (Feld für allgemeine Hinweise),SG4,FTX,,00043,,,,Kann, + 45,Bemerkung (Feld für allgemeine Hinweise),SG4,FTX,4451,00043,ACB,,ZusätzlicheInformationen (fürallgemeine Hinweise),X, + 46,Bemerkung (Feld für allgemeine Hinweise),SG4,FTX,4440,00043,,,Text für allgemeine Information,X, + 47,Netzlokation,SG5,,,,,,,Soll [46] ∧ [688],"[46] Wenn ID für Objekt vergeben wurde + [688] Hinweis: Es sind alle ID der Netzlokationen, welche der im LOC+Z16 angegebenen Marktlokation vorgelagert sind anzugeben" + 48,Netzlokation,SG5,LOC,,00050,,,,Muss, + 49,Netzlokation,SG5,LOC,3227,00050,Z18,,Netzlokation,X, + 50,Netzlokation,SG5,LOC,3225,00050,,,ID der Netzlokation,X [960],[960] Format: Netzlokations- ID + 51,Marktlokation,SG5,,,,,,,Muss [2061],[2061] Segment bzw. Segmentgruppe ist genau einmal je SG4 IDE (Vorgang) anzugeben + 52,Marktlokation,SG5,LOC,,00051,,,,Muss, + 53,Marktlokation,SG5,LOC,3227,00051,Z16,,Marktlokation,X, + 54,Marktlokation,SG5,LOC,3225,00051,,,ID der Marktlokation,X [950],[950] Format: Marktlokations-ID + 55,Technische Ressource,SG5,,,,,,,Soll [46] ∧ [689]∧ [694],"[46] Wenn ID für Objekt vergeben wurde + [689] Hinweis: Es sind alle ID der Technischen Ressourcen, welche der im LOC+Z16 angegebenen Marktlokation zugehören anzugeben + [694] Hinweis: Wenn in einer Marktlokation eine ID für eine Technischen Ressource vergeben wird, müssen für alle ggf. weitere Technische Ressourcen in der Marktlokation ID vergeben werden. Hintergrund: MSB und LF benötigen einen vollständigen Überblick auf die Art und Nutzung der Technischen Ressourcen in einer Marktlokation für die Plausibilisierung, Ersatzwertbildung," + 56,Technische Ressource,SG5,LOC,,00052,,,,Muss, + 57,Technische Ressource,SG5,LOC,3227,00052,Z20,,Technische Ressource,X, + 58,Technische Ressource,SG5,LOC,3225,00052,,,ID der Technischen Ressource,X [922],[922] Format: TR-ID + 59,Steuerbare Ressource,SG5,,,,,,,Soll [46] ∧ [690],"[46] Wenn ID für Objekt vergeben wurde + [690] Hinweis: Es sind alle ID der Steuerbaren Ressourcen, welche der im LOC+Z20 angegebenen Technischen Ressourcen zugeordnet sind anzugeben" + 60,Steuerbare Ressource,SG5,LOC,,00053,,,,Muss, + 61,Steuerbare Ressource,SG5,LOC,3227,00053,Z19,,Steuerbare Ressource,X, + 62,Steuerbare Ressource,SG5,LOC,3225,00053,,,ID der Steuerbaren Ressource,X [961],[961] Format: SR-ID + 63,Tranche,SG5,,,,,,,,[166] Wenn vorhanden + 64,Tranche,SG5,LOC,,00054,,,,, + 65,Tranche,SG5,LOC,3227,00054,Z21,,Tranche,, + 66,Tranche,SG5,LOC,3225,00054,,,ID der Tranche,,[950] Format: Marktlokations-ID + 67,Messlokation,SG5,,,,,,,Soll [165],[165] Wenn bekannt + 68,Messlokation,SG5,LOC,,00055,,,,Muss, + 69,Messlokation,SG5,LOC,3227,00055,Z17,,Messlokation,X, + 70,Messlokation,SG5,LOC,3225,00055,,,ID der Messlokation,X [951],[951] Format: Zählpunktbezeichnung + 71,Prüfidentifikator,SG6,,,,,,,Muss, + 72,Prüfidentifikator,SG6,RFF,,00057,,,,Muss, + 73,Prüfidentifikator,SG6,RFF,1153,00057,Z13,,Prüfidentifikator,X, + 74,Prüfidentifikator,SG6,RFF,1154,00057,55035,,GPKE / Antwort auf dieGeschäftsdatenanfrage,X, + 75,Prüfidentifikator,SG6,RFF,1154,,55215,,GPKE / Antwort auf dieGeschäftsdatenanfragedes ÜNB,, + 76,Referenz auf eine vorangegangene Anfrage,SG6,,,,,,,Muss, + 77,Referenz auf eine vorangegangene Anfrage,SG6,RFF,,00060,,,,Muss, + 78,Referenz auf eine vorangegangene Anfrage,SG6,RFF,1153,00060,AAV,,Nummer der Anfrage,X, + 79,Referenz auf eine vorangegangene Anfrage,SG6,RFF,1154,00060,,,Vorgangsnummer,X, + 80,Referenz auf die ID der Marktlokation für Termine der Marktlokation,SG6,,,,,,,Muss, + 81,Referenz auf die ID der Marktlokation für Termine der Marktlokation,SG6,RFF,,00066,,,,Muss [636],[636] Hinweis: Dieses RFF + 82,Referenz auf die ID der Marktlokation für Termine der Marktlokation,SG6,RFF,1153,00066,Z18,,Marktlokation,X, + 83,Referenz auf die ID der Marktlokation für Termine der Marktlokation,SG6,RFF,1154,00066,,,ID der Marktlokation,X [950],[950] Format: Marktlokations-ID + 84,Turnusablesung des MSB,SG6,DTM,,00067,,,,Muss [21] ∧[234],"[21] Wenn SG10 CCI+++ZA6 (Prognose auf Basis von Profilen) in dieser SG8 vorhanden + [234] Wenn SG10 CCI+++Z83 (Messtechnische Einordnung der Marktlokation) CAV+Z53 (kME/ mME) vorhanden" + 85,Turnusablesung des MSB,SG6,DTM,2005,00067,752,,Turnusablesung,X, + 86,Turnusablesung des MSB,SG6,DTM,2380,00067,,,"Datum oder Uhrzeit oderZeitspanne, Wert",X, + 87,Turnusablesung des MSB,SG6,DTM,2379,00067,104,,MMWW-MMWW,X, + 88,Turnusablesung des MSB,SG6,DTM,2379,,106,,MMDD,X, + 89,Termin der Netznutzungsabrechnung,SG6,DTM,,00068,,,,Muss, + 90,Termin der Netznutzungsabrechnung,SG6,DTM,2005,00068,Z21,,Termin derNetznutzungsabrechnung,X, + 91,Termin der Netznutzungsabrechnung,SG6,DTM,2380,00068,,,"Datum oder Uhrzeit oderZeitspanne, Wert",X, + 92,Termin der Netznutzungsabrechnung,SG6,DTM,2379,00068,106,,MMDD,X, + 93,Termin der Netznutzungsabrechnung,SG6,DTM,2379,,104,,MMWW-MMWW,X, + 94,Netznutzungsabrechnungsi ntervall des NB,SG6,DTM,,00070,,,,Muss, + 95,Netznutzungsabrechnungsi ntervall des NB,SG6,DTM,2005,00070,Z22,,Netznutzungsabrechnungs- bzw.Einspeisevergütungsintervall des NB,X, + 96,Netznutzungsabrechnungsi ntervall des NB,SG6,DTM,2380,00070,,,"Datum oder Uhrzeit oderZeitspanne, Wert",X, + 97,Netznutzungsabrechnungsi ntervall des NB,SG6,DTM,2379,00070,802,,Monat,X, + 98,Referenz auf die Lokationsbündelstruktur,SG8,,,,,,,Muss [309] ∧[513] ∧ [2061],[309] Wenn DTM+137 (Nachrichtendatum) im DE2380 ≥ 202409302200?+00 + 99,Referenz auf die Lokationsbündelstruktur,SG8,SEQ,,00071,,,,Muss, + 100,Referenz auf die Lokationsbündelstruktur,SG8,SEQ,1229,00071,Z78,,Referenz auf dieLokationsbündelstruktur,X, + 101,Referenz auf die Lokationsbündelstruktur,SG8,RFF,,00072,,,,Muss, + 102,Referenz auf die Lokationsbündelstruktur,SG8,RFF,1153,00072,Z31,,Lokationsbündelstruktur,X, + 103,Referenz auf die Lokationsbündelstruktur,SG8,RFF,1153,,Z39,,Keine standardisierteLokationsbündelstrukturvorhanden,X, + 104,Referenz auf die Lokationsbündelstruktur,SG8,RFF,1154,00072,,,ID der Lokationsbündelstruktur,X [335],"[335] Wenn im SG8 SEQ+Z78 RFF+Z31 ""Referenz auf die Lokationsbündelstruktur"" im DE1153 der Code Z31 ""Lokationsbündelstruktur"" vorhanden ist" + 105,Referenz auf die Lokationsbündelstruktur,SG8,RFF,1156,00072,,,Fortlaufende Nummer einesLokationsbündels imGeschäftsvorfall,M [914] ∧ [937][32],"[32] Wenn mehr als ein SG8 SEQ+Z78 (Referenz auf die Lokationsbündelstruktur) vorhanden + [914] Format: Möglicher Wert: > 0 + [937] Format: keine Nachkommastelle" + 106,Zuordnung Lokation zum Objektcode des Lokationsbündels,SG8,,,,,,,Muss [2354] ∧[335] ∧ [513],"[335] Wenn im SG8 SEQ+Z78 RFF+Z31 ""Referenz auf die Lokationsbündelstruktur"" im DE1153 der Code Z31 ""Lokationsbündelstruktur"" vorhanden ist " + 107,Zuordnung Lokation zum Objektcode des Lokationsbündels,SG8,SEQ,,00073,,,,Muss, + 108,Zuordnung Lokation zum Objektcode des Lokationsbündels,SG8,SEQ,1229,00073,Z58,,Zuordnung Lokation zumObjektcode desLokationsbündels,X, + 109,Referenz auf die ID der Netzlokation / Marktlokation / Messlokation / Technischen Ressource,SG8,RFF,,00074,,,,Muss, + 110,Referenz auf die ID der Netzlokation / Marktlokation / Messlokation / Technischen Ressource,SG8,RFF,1153,00074,Z32,,Netzlokation,X, + 111,Referenz auf die ID der Netzlokation / Marktlokation / Messlokation / Technischen Ressource,SG8,RFF,1153,,Z18,,Marktlokation,X, + 112,Referenz auf die ID der Netzlokation / Marktlokation / Messlokation / Technischen Ressource,SG8,RFF,1153,,Z19,,Messlokation,X, + 113,Referenz auf die ID der Netzlokation / Marktlokation / Messlokation / Technischen Ressource,SG8,RFF,1153,,Z37,,Technische Ressource,X, + 114,Referenz auf die ID der Netzlokation / Marktlokation / Messlokation / Technischen Ressource,SG8,RFF,1154,00074,,,ID einer Lokation,X ([451] ∧ [950])⊻ ([452] ∧[951]) ⊻ ([450]∧ [960]) ⊻([456] ∧ [922]),"[450] Wenn in demselben RFF der Code Z32 (Netzlokation) im DE1153 vorhanden + [451] Wenn in demselben RFF der Code Z18 (Marktlokation) im DE1153 vorhanden + [452] Wenn in demselben RFF der Code Z19 (Messlokation) im DE1153 vorhanden + [456] Wenn in demselben RFF der Code Z37 (Technische Ressource) im DE1153 vorhanden + [922] Format: TR-ID + [950] Format: Marktlokations-ID " + 115,Referenz auf den Objektcode in der Lokationsbündelstruktur,SG8,RFF,,00075,,,,Muss [2313],[2313] Je SG8 SEQ+Z58 (Zuordnung Lokation zum Objektcode des Lokationsbündels) genau einmal anzugeben + 116,Referenz auf den Objektcode in der Lokationsbündelstruktur,SG8,RFF,1153,00075,Z33,,Objektcode der Lokationin derLokationsbündelstruktur,X, + 117,Referenz auf den Objektcode in der Lokationsbündelstruktur,SG8,RFF,1154,00075,,,Objekt Code,X, + 118,Referenz auf den Objektcode in der Lokationsbündelstruktur,SG8,RFF,1156,00075,,,Fortlaufende Nummer einesLokationsbündels imGeschäftsvorfall,M [914] ∧ [937][32],"[32] Wenn mehr als ein SG8 SEQ+Z78 (Referenz auf die Lokationsbündelstruktur) vorhanden + [914] Format: Möglicher Wert: > 0 + [937] Format: keine Nachkommastelle" + 119,Referenz auf die ID der vorgelagerten Netzlokation / Messlokation ,SG8,RFF,,00076,,,,Muss [290],[290] Wenn der Objektcode im RFF+Z33 (Referenz auf den Objektcode in der Lokationsbündelstruktur) im DE1154 derselben SG8 SEQ+Z58 (Zuordnung Lokation zum Objektcode des Lokationsbündels) in einem weiteren SG8 SEQ+Z58 vorhanden ist + 120,Referenz auf die ID der vorgelagerten Netzlokation / Messlokation ,SG8,RFF,1153,00076,Z34,,vorgelagerteMesslokation,X, + 121,Referenz auf die ID der vorgelagerten Netzlokation / Messlokation ,SG8,RFF,1153,,Z35,,vorgelagerteNetzlokation,X, + 122,Referenz auf die ID der vorgelagerten Netzlokation / Messlokation ,SG8,RFF,1154,00076,,,ID einer Lokation,X ([472] ∧ [951])⊻ ([471] ∧[960]),"[471] Wenn in demselben RFF der Code Z35 (vorgelagerte Netzlokation) im DE1153 vorhanden + [472] Wenn in demselben RFF der Code Z34 (vorgelagerte Messlokation) im DE1153" + 123,Referenz auf die der Technischen Ressource zugeordneten Marktlokation ,SG8,RFF,,00077,,,,Muss [290] ∧[291],"[290] Wenn der Objektcode im RFF+Z33 (Referenz auf den Objektcode in der Lokationsbündelstruktur) im DE1154 derselben SG8 SEQ+Z58 (Zuordnung Lokation zum Objektcode des Lokationsbündels) in einem weiteren SG8 SEQ+Z58 vorhanden ist + [291] Wenn in derselben SG8 SEQ+Z58 (Zuordnung Lokation zum Objektcode des Lokationsbündels) das RFF+Z37 vorhanden" + 124,Referenz auf die der Technischen Ressource zugeordneten Marktlokation ,SG8,RFF,1153,00077,Z16,,zugeordneteMarktlokation,X, + 125,Referenz auf die der Technischen Ressource zugeordneten Marktlokation ,SG8,RFF,1154,00077,,,ID der Marktlokation,X [950],[950] Format: Marktlokations-ID + 126,Daten der Netzlokation,SG8,,,,,,,Muss [294] ∧[2356],"[294] Wenn SG5 LOC+Z18 (Netzlokation) vorhanden + [2356] Je SG5 LOC+Z18 (Netzlokation) ist genau einmal die Segmentgruppe anzugeben" + 127,Daten der Netzlokation,SG8,SEQ,,00078,,,,Muss, + 128,Daten der Netzlokation,SG8,SEQ,1229,00078,Z51,,Daten der Netzlokation,X, + 129,Referenz auf die ID der Netzlokation,SG8,RFF,,00079,,,,Muss, + 130,Referenz auf die ID der Netzlokation,SG8,RFF,1153,00079,Z32,,Netzlokation,X, + 131,Referenz auf die ID der Netzlokation,SG8,RFF,1154,00079,,,ID der Netzlokation,X [960],[960] Format: Netzlokations- ID + 132,Steuerkanal,SG10,,,,,,,Muss, + 133,Steuerkanal,SG10,CCI,,00080,,,,Muss, + 134,Steuerkanal,SG10,CCI,7059,00080,Z49,,Steuerkanal,X, + 135,Steuerkanal,SG10,CCI,7037,00080,ZF2,,Kein Steuerkanalvorhanden,X, + 136,Steuerkanal,SG10,CCI,7037,,ZF3,,Steuerkanal vorhanden,X, + 137,Zugeordnete Marktpartner,SG10,,,,,,,Muss, + 138,Zugeordnete Marktpartner,SG10,CCI,,00081,,,,Muss, + 139,Zugeordnete Marktpartner,SG10,CCI,7037,00081,ZB3,,ZugeordneterMarktpartner,X, + 140,Messstellenbetreiber,SG10,CAV,,00082,,,,Muss, + 141,Messstellenbetreiber,SG10,CAV,7111,00082,Z91,,MSB,X, + 142,Messstellenbetreiber,SG10,CAV,1131,00082,,,MP-ID,X, + 143,Messstellenbetreiber,SG10,CAV,7110,00082,Z39,,GrundzuständigerMessstellenbetreiber,X, + 144,Messstellenbetreiber,SG10,CAV,7110,,Z40,,WettbewerblicherMessstellenbetreiber,X, + 145,Messstellenbetreiber,SG10,CAV,7110,,Z41,,Auffangmessstellenbetreiber,X, + 146,OBIS-Daten der Netzlokation,SG8,,,,,,,Soll [166] ∧[294],"[166] Wenn vorhanden + [294] Wenn SG5 LOC+Z18 (Netzlokation) vorhanden" + 147,OBIS-Daten der Netzlokation,SG8,SEQ,,00088,,,,Muss, + 148,OBIS-Daten der Netzlokation,SG8,SEQ,1229,00088,Z57,,OBIS-Daten derNetzlokation,X, + 149,Referenz auf die ID der Netzlokation,SG8,RFF,,00089,,,,Muss, + 150,Referenz auf die ID der Netzlokation,SG8,RFF,1153,00089,Z32,,Netzlokation,X, + 151,Referenz auf die ID der Netzlokation,SG8,RFF,1154,00089,,,ID der Netzlokation,X [960],[960] Format: Netzlokations- ID + 152,OBIS-Kennzahl der Netzlokation,SG8,PIA,,00090,,,,Muss, + 153,OBIS-Kennzahl der Netzlokation,SG8,PIA,4347,00090,5,,Produktidentifikation,X, + 154,OBIS-Kennzahl der Netzlokation,SG8,PIA,7140,00090,,,OBIS-Kennzahl der Netzlokation,X, + 155,OBIS-Kennzahl der Netzlokation,SG8,PIA,7143,00090,SRW,,OBIS-Kennzahl,X, + 156,Produkt-Daten für Lieferant relevant,SG10,,,,,,,Muss, + 157,Produkt-Daten für Lieferant relevant,SG10,CCI,,00093,,,,Muss, + 158,Produkt-Daten für Lieferant relevant,SG10,CCI,7037,00093,ZA7,,LF,X, + 159,Verwendungszweck der Werte,SG10,CAV,,00094,,,,Muss, + 160,Verwendungszweck der Werte,SG10,CAV,7111,00094,Z47,,Endkundenabrechnung,X [1P1..1], + 161,Verwendungszweck der Werte,SG10,CAV,7111,,ZD1,,Blindarbeitabrechnung /Betriebsführung,X [1P1..1], + 162,Produkt-Daten der Netzlokation,SG8,,,,,,,Soll [166] ∧[294],"[166] Wenn vorhanden + [294] Wenn SG5 LOC+Z18 (Netzlokation) vorhanden" + 163,Produkt-Daten der Netzlokation,SG8,SEQ,,00095,,,,Muss, + 164,Produkt-Daten der Netzlokation,SG8,SEQ,1229,00095,Z60,,Produkt-Daten derNetzlokation,X, + 165,Referenz auf die ID der Netzlokation,SG8,RFF,,00096,,,,Muss, + 166,Referenz auf die ID der Netzlokation,SG8,RFF,1153,00096,Z32,,Netzlokation,X, + 167,Referenz auf die ID der Netzlokation,SG8,RFF,1154,00096,,,ID einer Netzlokation,X [960],[960] Format: Netzlokations- ID + 168,Produkt-Daten der Netzlokation,SG8,PIA,,00097,,,,Muss, + 169,Produkt-Daten der Netzlokation,SG8,PIA,4347,00097,5,,Produktidentifikation,X, + 170,Produkt-Daten der Netzlokation,SG8,PIA,7140,00097,,,Konfigurationsprodukt-Code,X [412],"[412] Es sind ausschließlich Konfigurationsprodukt-Codes der ""EDI@Energy Codeliste der Konfigurationen"" aus Kapitel 4.2 Konfigurationsprodukte Leistungskurvendefinition erlaubt" + 171,Produkt-Daten der Netzlokation,SG8,PIA,7143,00097,Z12,,Konfigurationsprodukt,X, + 172,Zugeordnete Leistungskurvendefinition,SG10,,,,,,,Muss [190],[190] Wenn in derselben SG8 SEQ+Z60 (Produkt-Daten der Netzlokation) PIA+5+9991000000721:Z12 vorhanden + 173,Zugeordnete Leistungskurvendefinition,SG10,CCI,,00099,,,,Muss, + 174,Zugeordnete Leistungskurvendefinition,SG10,CCI,7059,00099,Z53,,Code derLeistungskurvendefinition,X, + 175,Zugeordnete Leistungskurvendefinition,SG10,CCI,7037,00099,,,Code derLeistungskurvendefinition,X, + 176,Auftraggebender Marktpartner,SG10,,,,,,,Muss, + 177,Auftraggebender Marktpartner,SG10,CCI,,00100,,,,Muss, + 178,Auftraggebender Marktpartner,SG10,CCI,7037,00100,ZB3,,ZugeordneterMarktpartner,X, + 179,Auftraggebender Marktpartner,SG10,CAV,,00101,,,,Muss, + 180,Auftraggebender Marktpartner,SG10,CAV,7111,00101,Z88,,NB,X, + 181,Auftraggebender Marktpartner,SG10,CAV,7111,,Z89,,LF,X, + 182,Auftraggebender Marktpartner,SG10,CAV,1131,00101,,,MP-ID,X, + 183,Produkt-Daten für Marktrolle relevant,SG10,,,,,,,Muss, + 184,Produkt-Daten für Marktrolle relevant,SG10,CCI,,00102,,,,Muss, + 185,Produkt-Daten für Marktrolle relevant,SG10,CCI,7037,00102,ZA7,,LF,X, + 186,Daten der Marktlokation,SG8,,,,,,,Muss [2061],[2061] Segment bzw. Segmentgruppe ist genau einmal je SG4 IDE (Vorgang) anzugeben + 187,Daten der Marktlokation,SG8,SEQ,,00103,,,,Muss, + 188,Daten der Marktlokation,SG8,SEQ,1229,00103,Z01,,Daten der Marktlokation,X, + 189,Referenz auf die ID der Marktlokation,SG8,RFF,,00104,,,,Muss, + 190,Referenz auf die ID der Marktlokation,SG8,RFF,1153,00104,Z18,,Marktlokation,X, + 191,Referenz auf die ID der Marktlokation,SG8,RFF,1154,00104,,,ID der Marktlokation,X [950],[950] Format: Marktlokations-ID + 192,Arbeit / Leistung für tagesparameterabhängige Marktlokation,SG9,,,,,,,Muss [101],"[101] Wenn SG10 CCI+++ZA6 (Prognosegrundlage der Marktlokation: Prognose auf Basis von Profilen) CAV+E14/ Z36 (TLP/ TEP/ TEP mit Ref. messung) in dieser SG8 vorhanden + [243] Wenn SG10 CCI+6++ZA8 (Aggreg.verantw. NB) in dieser SG8 vorhanden" + 193,Arbeit / Leistung für tagesparameterabhängige Marktlokation,SG9,QTY,,00105,,,,Muss, + 194,Arbeit / Leistung für tagesparameterabhängige Marktlokation,SG9,QTY,6063,00105,Z10,,Leistung derMarktlokation,, + 195,Arbeit / Leistung für tagesparameterabhängige Marktlokation,SG9,QTY,6063,,265,,VeranschlagteJahresmenge Gesamt/Jahresverbrauchsprognose für spezifische Arbeit,X,[102] Wenn SG10 CCI+++ZA6 (Prognosegrundlage der Marktlokation: Prognose auf Basis von Profilen) CAV+Z36 (TEP mit Ref.messung) in dieser SG8 vorhanden + 196,Arbeit / Leistung für tagesparameterabhängige Marktlokation,SG9,QTY,6060,00105,,,Menge,X [902],[902] Format: Möglicher Wert: ≥ 0 + 197,Arbeit / Leistung für tagesparameterabhängige Marktlokation,SG9,QTY,6411,00105,Z16,,kWh/K (Kilowatt-Stunde/Kelvin),X [103], + 198,Arbeit / Leistung für tagesparameterabhängige Marktlokation,SG9,QTY,6411,,KWH,,Kilowattstunde,X [104], + 199,Arbeit / Leistung für tagesparameterabhängige Marktlokation,SG9,QTY,6411,,KWT,,Kilowatt,,"[103] Wenn SG9 QTY+265 (Arbeit / Leistung für tagesparameterabhängig e Marktlokation: Veranschlagte Jahresmenge Gesamt) in dieser SG8 vorhanden + [104] Wenn SG9 QTY+Z08 (Arbeit / Leistung für tagesparameterabhängige Marktlokation: angepasste elektrische Arbeit nach Anhang D) in dieser SG8 vorhanden + [105] Wenn SG9 QTY+Z10 (Arbeit / Leistung für tagesparameterabhängige Marktlokation: Leistung der Marktlokation) in dieser SG8 vorhanden" + 200,Veranschlagte Jahresmenge gesamt,SG9,,,,,,,Muss [106],"[106] Wenn in dieser SG8 SEQ+Z01 SG10 CCI+++ZA6 (Prognosegrundlage der Marktlokation: Prognose auf Basis von Profilen) CAV+E02 (SLP/SEP) vorhanden + [332] Wenn im SG8 SEQ+Z01 (Daten der Marktlokation) das SG10 CCI+6++ZA9 (Aggreg. verantw. ÜNB) nicht vorhanden" + 201,Veranschlagte Jahresmenge gesamt,SG9,QTY,,00106,,,,Muss, + 202,Veranschlagte Jahresmenge gesamt,SG9,QTY,6063,00106,31,,VeranschlagteJahresmenge Gesamt,X, + 203,Veranschlagte Jahresmenge gesamt,SG9,QTY,6060,00106,,,Mengenangabe,X [902] ∧ [937],"[902] Format: Möglicher Wert: ≥ 0 + [937] Format: keine Nachkommastelle" + 204,Veranschlagte Jahresmenge gesamt,SG9,QTY,6411,00106,KWH,,Kilowattstunde,X, + 205,Lieferrichtung,SG10,,,,,,,Muss, + 206,Lieferrichtung,SG10,CCI,,00110,,,,Muss, + 207,Lieferrichtung,SG10,CCI,7059,00110,Z30,,Lieferrichtung,X, + 208,Lieferrichtung,SG10,CCI,7037,00110,Z06,,Erzeugung,, + 209,Lieferrichtung,SG10,CCI,7037,,Z07,,Verbrauch,X, + 210,Zugeordnete Marktpartner,SG10,,,,,,,Muss, + 211,Zugeordnete Marktpartner,SG10,CCI,,00111,,,,Muss, + 212,Zugeordnete Marktpartner,SG10,CCI,7037,00111,ZB3,,ZugeordneterMarktpartner,X, + 213,Lieferant,SG10,CAV,,00113,,,,,[300] Wenn SG8 SEQ+Z15 (Daten der Tranche) nicht vorhanden + 214,Lieferant,SG10,CAV,7111,00113,Z89,,LF,, + 215,Lieferant,SG10,CAV,1131,00113,,,MP-ID,,"[611] Hinweis: Wenn das Unternehmen NB die Aufgaben der Marktrolle LF wahrnimmt, ist die MP-ID des Unternehmens NB in der Marktrolle LF anzugeben" + 216,Übertragungsnetzbetreiber,SG10,CAV,,00114,,,,Muss, + 217,Übertragungsnetzbetreiber,SG10,CAV,7111,00114,Z90,,ÜNB,X, + 218,Übertragungsnetzbetreiber,SG10,CAV,1131,00114,,,MP-ID,X, + 219,Messstellenbetreiber,SG10,CAV,,00115,,,,Muss [232] ⊻[234],"[19] Wenn SG8 SEQ+Z01 (Daten der Marktlokation) SG10 CCI+++ZC0 (Prognose auf Basis von Werten) vorhanden + [232] Wenn SG10 CCI+++Z83 CAV+Z52 (Messtechnische Einordnung der Marktlokation: iMS) vorhanden + [234] Wenn SG10 CCI+++Z83 (Messtechnische Einordnung der Marktlokation) CAV+Z53 (kME/ mME) vorhanden" + 220,Messstellenbetreiber,SG10,CAV,7111,00115,Z91,,MSB,X, + 221,Messstellenbetreiber,SG10,CAV,1131,00115,,,MP-ID,X, + 222,Messstellenbetreiber,SG10,CAV,7110,00115,Z19,,Auf vertraglicherGrundlage gegenüberAnschlussnutzer /,X, + 223,Messstellenbetreiber,SG10,CAV,7110,00115,Z39,,GrundzuständigerMessstellenbetreiber,X, + 224,Messstellenbetreiber,SG10,CAV,7110,,Z40,,WettbewerblicherMessstellenbetreiber,X, + 225,Messstellenbetreiber,SG10,CAV,7110,,Z41,,Auffangmessstellenbetreiber,X, + 226,Regelzone,SG10,,,,,,,Muss, + 227,Regelzone,SG10,CCI,,00116,,,,Muss, + 228,Regelzone,SG10,CCI,7059,00116,Z18,,Regelzone,X, + 229,Regelzone,SG10,CCI,7037,00116,,,Regelzone,X, + 230,Bilanzierungsgebiet,SG10,,,,,,,Muss, + 231,Bilanzierungsgebiet,SG10,CCI,,00118,,,,Muss, + 232,Bilanzierungsgebiet,SG10,CCI,7059,00118,Z20,,Bilanzierungsgebiet,X, + 233,Bilanzierungsgebiet,SG10,CCI,7037,00118,,,Bilanzierungsgebiet,X, + 234,Verbrauchsaufteilung für temperaturabhängige Marktlokation,SG10,,,,,,,Muss [89] ∧[106],"[89] Wenn im SG8 SEQ+Z01 (Daten der Marktlokation) das SG10 CCI+++ZA6 (Prognosegrundlage der Marktlokation: Prognose auf Basis von Profilen) CAV+E14 (TLP/TEP) vorhanden + [106] Wenn in dieser SG8 SEQ+Z01 SG10 CCI+++ZA6 (Prognosegrundlage der Marktlokation: Prognose auf Basis von Profilen) CAV+E02 (SLP/SEP) vorhanden" + 235,Verbrauchsaufteilung für temperaturabhängige Marktlokation,SG10,CCI,,00119,,,,Muss, + 236,Verbrauchsaufteilung für temperaturabhängige Marktlokation,SG10,CCI,7037,00119,E17,,Verbrauchsaufteilung (in%) fürtemperaturabhängigeMarktlokation,X, + 237,Verbrauchsaufteilung für temperaturabhängige Marktlokation,SG10,CAV,,00120,,,,Muss, + 238,Verbrauchsaufteilung für temperaturabhängige Marktlokation,SG10,CAV,7111,00120,Z22,,Verbrauchsaufteilung in%,X, + 239,Verbrauchsaufteilung für temperaturabhängige Marktlokation,SG10,CAV,7110,00120,,,Verbrauchsaufteilung in %,X [902],[902] Format: Möglicher Wert: ≥ 0 + 240,Zeitreihentyp,SG10,,,,,,,Muss [2061] ⊻([90] ∧ [2096]),"[90] Wenn SG10 CCI+++ZA6 (Prognosegrundlage der Marktlokation: Prognose auf Basis von Profilen) einmal mit CAV+E14 (TLP/TEP) und einmal mit CAV+E02 (SLP/SEP) in dieser SG8 vorhanden + [2061] Segment bzw. Segmentgruppe ist genau einmal je SG4 IDE (Vorgang) anzugeben + [2096] Segmentgruppe ist genau zweimal je SG4 IDE anzugeben" + 241,Zeitreihentyp,SG10,CCI,,00121,,,,Muss, + 242,Zeitreihentyp,SG10,CCI,7059,00121,15,,Struktur,X, + 243,Zeitreihentyp,SG10,CCI,7037,00121,Z21,,Summenzeitreihentyp,X, + 244,Zeitreihentyp,SG10,CAV,,00122,,,,Muss, + 245,Zeitreihentyp,SG10,CAV,7111,00122,,,Code des Zeitreihentyps,X, + 246,Spannungsebene der Marktlokation,SG10,,,,,,,Muss, + 247,Spannungsebene der Marktlokation,SG10,CCI,,00123,,,,Muss, + 248,Spannungsebene der Marktlokation,SG10,CCI,7037,00123,E03,,Spannungsebene derMarktlokation,X, + 249,Spannungsebene der Marktlokation,SG10,CAV,,00124,,,,Muss, + 250,Spannungsebene der Marktlokation,SG10,CAV,7111,00124,E03,,Höchstspannung,X, + 251,Spannungsebene der Marktlokation,SG10,CAV,7111,,E04,,Hochspannung,X, + 252,Spannungsebene der Marktlokation,SG10,CAV,7111,,E05,,Mittelspannung,X, + 253,Spannungsebene der Marktlokation,SG10,CAV,7111,,E06,,Niederspannung,X, + 254,Umspannung der Marktlokation,SG10,CAV,,00125,,,,Soll [166],[166] Wenn vorhanden + 255,Umspannung der Marktlokation,SG10,CAV,7111,00125,E07,,Hös/HS Umspannung,X [116], + 256,Umspannung der Marktlokation,SG10,CAV,7111,,E08,,HS/MS Umspannung,X [115], + 257,Umspannung der Marktlokation,SG10,CAV,7111,,E09,,MS/NS Umspannung,X [114],"[114] Wenn das SG10 CCI+E03 (Spannungsebene der Marktlokation) CAV E06 (Niederspannung) in dieser SG vorhanden + [115] Wenn das SG10 CCI+E03 (Spannungsebene der Marktlokation) CAV E05 (Mittelspannung) in dieser SG" + 258,Messtechnische Einordnung der Marktlokation,SG10,,,,,,,Muss, + 259,Messtechnische Einordnung der Marktlokation,SG10,CCI,,00126,,,,Muss, + 260,Messtechnische Einordnung der Marktlokation,SG10,CCI,7037,00126,Z83,,MesstechnischeEinordnung derMarktlokation,X, + 261,Messtechnische Einordnung der Marktlokation,SG10,CAV,,00127,,,,Muss, + 262,Messtechnische Einordnung der Marktlokation,SG10,CAV,7111,00127,Z52,,iMS,X, + 263,Messtechnische Einordnung der Marktlokation,SG10,CAV,7111,,Z53,,kME / mME,X, + 264,Messtechnische Einordnung der Marktlokation,SG10,CAV,7111,,Z68,,keine Messung,X, + 265,Aggregationsverantwortung in MaBiS,SG10,,,,,,,Muss, + 266,Aggregationsverantwortung in MaBiS,SG10,CCI,,00128,,,,Muss, + 267,Aggregationsverantwortung in MaBiS,SG10,CCI,7059,00128,6,,Verantwortlicher,X, + 268,Aggregationsverantwortung in MaBiS,SG10,CCI,7037,00128,ZA8,,NB,X, + 269,Aggregationsverantwortung in MaBiS,SG10,CCI,7037,,ZA9,,ÜNB,X, + 270,Prognosegrundlage der Marktlokation,SG10,,,,,,,Muss, + 271,Prognosegrundlage der Marktlokation,SG10,CCI,,00130,,,,Muss, + 272,Prognosegrundlage der Marktlokation,SG10,CCI,7037,00130,ZC0,,Prognose auf Basis von,X, + 273,Prognosegrundlage der Marktlokation,SG10,CCI,7037,,ZA6,,Prognose auf Basis von,X, + 274,Details der Prognosegrundlage,SG10,CAV,,00131,,,,Muss [21] ∧([2182] ⊻ ([90]∧ [2183])),"[21] Wenn SG10 CCI+++ZA6 (Prognose auf Basis von Profilen) in dieser SG8 vorhanden + [90] Wenn SG10 CCI+++ZA6 (Prognosegrundlage der Marktlokation: Prognose auf Basis von Profilen) einmal mit CAV+E14 (TLP/TEP) und einmal mit CAV+E02 (SLP/SEP)" + 275,Details der Prognosegrundlage,SG10,CAV,7111,00131,E02,,SLP/SEP,X [6P0..1] ⊻[7P1..1], + 276,Details der Prognosegrundlage,SG10,CAV,7111,,E14,,TLP/TEP,X [6P0..1], + 277,Details der Prognosegrundlage,SG10,CAV,7111,,Z36,,TEP mitReferenzmessung,, + 278,Wahlrecht der Prognosegrundlage der Marktlokation,SG10,,,,,,,Muss [244],[244] Wenn SG10 CCI+6++ZA9 (Aggreg.verantw. ÜNB) in dieser SG8 vorhanden + 279,Wahlrecht der Prognosegrundlage der Marktlokation,SG10,CCI,,00134,,,,Muss, + 280,Wahlrecht der Prognosegrundlage der Marktlokation,SG10,CCI,7037,00134,Z84,,Wahlrecht derPrognosegrundlage,X, + 281,Wahlrecht der Prognosegrundlage der Marktlokation,SG10,CAV,,00135,,,,Muss, + 282,Wahlrecht der Prognosegrundlage der Marktlokation,SG10,CAV,7111,00135,Z54,,Wahlrecht durch LFgegeben,X, + 283,Wahlrecht der Prognosegrundlage der Marktlokation,SG10,CAV,7111,,ZE2,,Wahlrecht durch LF nichtgegeben,X, + 284,Grund für nicht vorhandenes Wahlrecht der Prognosegrundlage der Marktlokation,SG10,CAV,,00136,,,,Muss [247],[247] Wenn CAV+ZE2 (Wahlrecht durch LF nicht gegeben) vorhanden + 285,Grund für nicht vorhandenes Wahlrecht der Prognosegrundlage der Marktlokation,SG10,CAV,7111,00136,Z55,,Wahlrecht nichtvorhanden wegenVerbrauch > 10.000kWh/a,X [1P0..1], + 286,Grund für nicht vorhandenes Wahlrecht der Prognosegrundlage der Marktlokation,SG10,CAV,7111,,ZC1,,Wahlrecht nichtvorhanden wegenEigenverbrauch,X [1P0..1], + 287,Grund für nicht vorhandenes Wahlrecht der Prognosegrundlage der Marktlokation,SG10,CAV,7111,,ZD2,,Wahlrecht nichtvorhanden wegentagesparameterabhängigem Verbrauch,X [1P0..1], + 288,Gruppenzuordnung (nach EnWG) ,SG10,,,,,,,Muss, + 289,Gruppenzuordnung (nach EnWG) ,SG10,CCI,,00139,,,,Muss, + 290,Gruppenzuordnung (nach EnWG) ,SG10,CCI,7037,00139,Z15,,Haushaltskunde gem.EnWG,X, + 291,Gruppenzuordnung (nach EnWG) ,SG10,CCI,7037,,Z18,,Kein Haushaltskundegem. EnWG,X, + 292,Netznutzung,SG10,,,,,,,Muss, + 293,Netznutzung,SG10,CCI,,00140,,,,Muss, + 294,Netznutzung,SG10,CCI,7037,00140,Z88,,Netznutzung,X, + 295,Netznutzungsvertrag,SG10,CAV,,00141,,,,Muss, + 296,Netznutzungsvertrag,SG10,CAV,7111,00141,Z74,,Netznutzungsvertrag,X, + 297,Netznutzungsvertrag,SG10,CAV,7110,00141,Z08,,Direkter Vertragzwischen Kunden und NB,X, + 298,Netznutzungsvertrag,SG10,CAV,7110,,Z09,,Vertrag zwischenLieferanten und NB,X, + 299,Zahlung der Netznutzung,SG10,CAV,,00142,,,,Soll [283],[283] Wenn Empfänger der Nachricht der zum Nachrichtendatum aktuell zugeordnete Lieferant ist + 300,Zahlung der Netznutzung,SG10,CAV,7111,00142,Z73,,Zahlung der Netznutzung,X, + 301,Zahlung der Netznutzung,SG10,CAV,7110,00142,Z10,,Kunde,X [216], + 302,Zahlung der Netznutzung,SG10,CAV,7110,,Z11,,Lieferant,X,[216] Wenn CCI+++Z88 (Netznutzung) CAV+Z74:::Z08 (Netznutzungsvertrag: Direkter Vertrag zwischen Kunden und NB) vorhanden + 303,Netznutzungsabrechnungsv ariante,SG10,CAV,,00143,,,,Muss, + 304,Netznutzungsabrechnungsv ariante,SG10,CAV,7111,00143,ZB1,,Netznutzungsabrechnungsvariante,X, + 305,Netznutzungsabrechnungsv ariante,SG10,CAV,7110,00143,Z14,,Arbeitspreis/Grundpreis,X, + 306,Netznutzungsabrechnungsv ariante,SG10,CAV,7110,,Z15,,Arbeitspreis/Leistungspreis,X, + 307,Grundlage der Lieferscheinprüfung,SG10,CAV,,00144,,,,Muss, + 308,Grundlage der Lieferscheinprüfung,SG10,CAV,7111,00144,ZA7,,Grundlage fürLieferscheinprüfung,X, + 309,Grundlage der Lieferscheinprüfung,SG10,CAV,7110,00144,Z12,,In derMarktkommunikationausgetauschte Daten,X, + 310,Grundlage der Lieferscheinprüfung,SG10,CAV,7110,,Z13,,Abweichend vertraglichmit Anschlussnutzervereinbarte Grundlage,X, + 311,Abwicklungsmodell,SG10,,,,,,,Muss, + 312,Abwicklungsmodell,SG10,CCI,,00153,,,,Muss, + 313,Abwicklungsmodell,SG10,CCI,7059,00153,ZA2,,Abwicklungsmodell,X, + 314,Abwicklungsmodell,SG10,CCI,7037,00153,ZE9,,"Modell 1 ""Bilanzierungan der Marktlokation""",X, + 315,Abwicklungsmodell,SG10,CCI,7037,,ZF0,,"Modell 2 ""Bilanzierungim Bilanzierungsgebiet(BG) des LPB""",X, + 316,Netznutzungsabrechnungsd aten der Marktlokation,SG8,,,,,,,Muss, + 317,Netznutzungsabrechnungsd aten der Marktlokation,SG8,SEQ,,00170,,,,Muss, + 318,Netznutzungsabrechnungsd aten der Marktlokation,SG8,SEQ,1229,00170,Z45,,Netznutzungsabrechnungsdaten derMarktlokation,X, + 319,Gruppenartikel-ID / Artikel- ID,SG8,PIA,,00171,,,,Muss, + 320,Gruppenartikel-ID / Artikel- ID,SG8,PIA,4347,00171,Z02,,Gruppenartikel-ID /Artikel-ID,X, + 321,Gruppenartikel-ID / Artikel- ID,SG8,PIA,7140,00171,,,Produkt-/Leistungsnummer,X ([942] ([270] ⊻[282]) ∧ [284])⊻ ([943] ([259] ⊻[261]) ∧ [284])⊻([957] [285] ∧[287]) ⊻([948] [286] ∧[287]) ,"[259] Wenn in diesem PIA der Code im DE7140 mit 1-01, 1- 03, 1-05 enthalten ist + [261] Wenn in diesem PIA der Code im DE7140 mit 1-07-1/2, 1-10-1/2/4/5/6/7/8/9, 1-11-1 beginnt + [270] Wenn in diesem PIA der Code im DE7140 mit 1-02, 1- 04, 1-06, 1-09 beginnt + [282] Wenn in diesem PIA der Code im DE7140 1-01-6-005, 1-01-9-001, 1-07-3-001, 1- 08-1-001, 1-08-3-001, 1-08- 4-001/002/003/004, 1-10-3- 001 enthalten ist + [284] Erlaubte Codes aus der Codeliste der Gruppenartikel- und Artikel-ID sind in der Spalte UTILMD/ Codeverwendung mit X" + 322,Gruppenartikel-ID / Artikel- ID,SG8,PIA,7143,00171,Z09,,Artikel-ID,X [393] ⊻ ([394]∧ [397]) ⊻ [395], + 323,Gruppenartikel-ID / Artikel- ID,SG8,PIA,7143,,Z10,,Gruppenartikel-ID,X [392] ⊻ ([394]∧ [398]),"[392] Wenn in diesem PIA der Code im Format n1-n2-n1 angegeben ist + [393] Wenn in diesem PIA der Code im Format n1-n2-n1-n3 angegeben ist + [394] Wenn in diesem PIA der Code im Format n1-n2-n1- n8-n2 angegeben ist + [395] Wenn in diesem PIA der Code im Format n1-n2-n1-n8 angegeben ist + [397] Wenn in diesem PIA der Code im DE7140 mit 1-08-1/ 1-08-4 beginnt + [398] Wenn in diesem PIA der Code im DE7140 mit 1-08-2/ 1-08-5 beginnt" + 324,Anzahl in der NNA abzurechenden Positionen der Gruppenartikel-ID / Artikel-ID,SG9,,,,,,,Muss [237],[237] Wenn in derselben SG8 im DE7140 des PIA+Z02 (Gruppenartikel-ID / Artikel- ID) eine Gruppenartikel-ID / Artikel-ID mit 1-06 (entspricht Entgelte des + 325,Anzahl in der NNA abzurechenden Positionen der Gruppenartikel-ID / Artikel-ID,SG9,QTY,,00172,,,,Muss, + 326,Anzahl in der NNA abzurechenden Positionen der Gruppenartikel-ID / Artikel-ID,SG9,QTY,6063,00172,Z38,,Anzahl derabzurechendenPositionen derGruppenartikel-ID /Artikel-ID,X, + 327,Anzahl in der NNA abzurechenden Positionen der Gruppenartikel-ID / Artikel-ID,SG9,QTY,6060,00172,,,Menge,X [914] ∧ [937],"[914] Format: Möglicher Wert: > 0 + [937] Format: keine Nachkommastelle" + 328,Anzahl in der NNA abzurechenden Positionen der Gruppenartikel-ID / Artikel-ID,SG9,QTY,6411,00172,PCS,,Stück,X, + 329,Gemeinderabatt,SG9,,,,,,,Muss, + 330,Gemeinderabatt,SG9,QTY,,00173,,,,Muss, + 331,Gemeinderabatt,SG9,QTY,6063,00173,Z16,,Gemeinderabatt,X, + 332,Gemeinderabatt,SG9,QTY,6060,00173,,,Menge,X [902] ∧ [930]∧ [938],"[902] Format: Möglicher Wert: ≥ 0 + [930] Format: max. 2 Nachkommastellen + [938] Format: Möglicher Wert: <= 10" + 333,Gemeinderabatt,SG9,QTY,6411,00173,P1,,Prozent,X, + 334,Zuschlag oder Abschlag,SG9,,,,,,,Muss, + 335,Zuschlag oder Abschlag,SG9,QTY,,00174,,,,Muss, + 336,Zuschlag oder Abschlag,SG9,QTY,6063,00174,Z34,,Zuschlag,X, + 337,Zuschlag oder Abschlag,SG9,QTY,6063,,Z35,,Abschlag,X, + 338,Zuschlag oder Abschlag,SG9,QTY,6063,,Z37,,Kein Zu-/Abschlag,X, + 339,Zuschlag oder Abschlag,SG9,QTY,6060,00174,,,Menge,X ([914] ∧ [930][140]) ⊻ ([926]∧ [937] [172]),"[140] Wenn im selben QTY im DE6063 Z34/Z35 (Zuschlag/ Abschlag) vorhanden + [172] Wenn im selben QTY im DE6063 Z37 (Kein Zu- und Abschlag) vorhanden + [914] Format: Möglicher Wert: > 0 + [926] Format: Möglicher Wert: 0 + [930] Format: max. 2 Nachkommastellen + [937] Format: keine Nachkommastelle" + 340,Zuschlag oder Abschlag,SG9,QTY,6411,00174,P1,,Prozent,X, + 341,Menge der Singulär genutzten Betriebsmittel,SG9,,,,,,,Muss [73],"[73] Wenn in derselben SG8 im PIA DE7140 ein Code aus der Codeliste der Gruppenartikel- und Artikel-ID vorhanden ist, der in der Spalte UTILMD/Preisangabe mit X gekennzeichnet ist" + 342,Menge der Singulär genutzten Betriebsmittel,SG9,QTY,,00175,,,,Muss, + 343,Menge der Singulär genutzten Betriebsmittel,SG9,QTY,6063,00175,Z33,,Singulär genutzteBetriebsmittel,X, + 344,Menge der Singulär genutzten Betriebsmittel,SG9,QTY,6060,00175,,,Menge,X, + 345,Preisangabe für Singulär genutzte Betriebsmittel,SG10,,,,,,,Muss [73],"[73] Wenn in derselben SG8 im PIA DE7140 ein Code aus der Codeliste der Gruppenartikel- und Artikel-ID vorhanden ist, der in der Spalte UTILMD/Preisangabe mit X gekennzeichnet ist" + 346,Preisangabe für Singulär genutzte Betriebsmittel,SG10,CCI,,00176,,,,Muss, + 347,Preisangabe für Singulär genutzte Betriebsmittel,SG10,CCI,7059,00176,Z44,,Berechnungspreis,X, + 348,Preisangabe für Singulär genutzte Betriebsmittel,SG10,CCI,7037,00176,ZD8,,Tag,X, + 349,Preisangabe für Singulär genutzte Betriebsmittel,SG10,CCI,7036,00176,,,"Preis, Betrag",X [914] ∧ [946],"[914] Format: Möglicher Wert: > 0 + [946] Format: max. 11 Nachkommastellen" + 350,Zugeordnete Zählzeitdefinition,SG10,,,,,,,Muss [59] ∧[108],"[59] Wenn mehr als eine SG8 SEQ+Z45 (Netznutzungsabrechnungsdat en der Marktlokation) mit einer Gruppen-/Artikel-ID im SG8 PIA+Z02 (Gruppenartikel- ID / Artikel-ID), welche mit 1- 08-1/2/3/4/5 beginnt, vorhanden + [108] Wenn in derselben SG8 SEQ+Z45 (Netznutzungsabrechnungsdat en der Marktlokation) eine Gruppen-/Artikel-ID im SG8 PIA+Z02 (Gruppenartikel-ID / Artikel-ID), welche mit 1-08- 1/2/3/4/5 beginnt, vorhanden" + 351,Zugeordnete Zählzeitdefinition,SG10,CCI,,00177,,,,Muss, + 352,Zugeordnete Zählzeitdefinition,SG10,CCI,7059,00177,Z39,,Code derZählzeitdefinition,X, + 353,Zugeordnete Zählzeitdefinition,SG10,CCI,7037,00177,,,Code der Zählzeitdefinition,X, + 354,Zugeordnetes Zählzeitregister ,SG10,,,,,,,Muss [59] ∧[108],"[59] Wenn mehr als eine SG8 SEQ+Z45 (Netznutzungsabrechnungsdat en der Marktlokation) mit einer Gruppen-/Artikel-ID im SG8 PIA+Z02 (Gruppenartikel- ID / Artikel-ID), welche mit 1- 08-1/2/3/4/5 beginnt, vorhanden + [108] Wenn in derselben SG8 SEQ+Z45 (Netznutzungsabrechnungsdat en der Marktlokation) eine Gruppen-/Artikel-ID im SG8 PIA+Z02 (Gruppenartikel-ID / Artikel-ID), welche mit 1-08- 1/2/3/4/5 beginnt, vorhanden" + 355,Zugeordnetes Zählzeitregister ,SG10,CCI,,00178,,,,Muss, + 356,Zugeordnetes Zählzeitregister ,SG10,CCI,7059,00178,Z38,,Code desZählzeitregisters,X, + 357,Zugeordnetes Zählzeitregister ,SG10,CCI,7037,00178,,,Code des Zählzeitregisters,X, + 358,OBIS-Daten der Marktlokation,SG8,,,,,,,Muss,"[19] Wenn SG8 SEQ+Z01 (Daten der Marktlokation) SG10 CCI+++ZC0 (Prognose auf Basis von Werten) vorhanden + [20] Wenn SG8 SEQ+Z01 (Daten der Marktlokation) SG10 CCI+Z30++Z07 (Verbrauch) vorhanden + [54] Wenn SG8 SEQ+Z01 (Daten der Marktlokation) SG10 CCI+Z30++Z06 (Lieferrichtung: Erzeugung) vorhanden + [300] Wenn SG8 SEQ+Z15 (Daten der Tranche) nicht vorhanden" + 359,OBIS-Daten der Marktlokation,SG8,SEQ,,00198,,,,Muss, + 360,OBIS-Daten der Marktlokation,SG8,SEQ,1229,00198,Z02,,OBIS-Daten derMarktlokation,X, + 361,Referenz auf die ID der Marktlokation,SG8,RFF,,00199,,,,Muss, + 362,Referenz auf die ID der Marktlokation,SG8,RFF,1153,00199,Z18,,Marktlokation,X, + 363,Referenz auf die ID der Marktlokation,SG8,RFF,1154,00199,,,ID einer Marktlokation,X [950],[950] Format: Marktlokations-ID + 364,OBIS-Kennzahl der Marktlokation,SG8,PIA,,00200,,,,Muss, + 365,OBIS-Kennzahl der Marktlokation,SG8,PIA,4347,00200,5,,Produktidentifikation,X, + 366,OBIS-Kennzahl der Marktlokation,SG8,PIA,7140,00200,,,OBIS-Kennzahl der Marktlokation,X [314],"[314] Es sind alle OBIS- Kennzahlen gem. EDI@Energy Codeliste der OBIS-Kennzahlen und Medien für den deutschen Energiemarkt Kap. 3 anzugeben, welche an der Marktlokation erforderlich sind. Der Mindestumfang der OBIS-Kennzahlen ergibt sich aus den genannten Messprodukt-Codes dem Kap. 5.1 des Dokumentes ""Codeliste der Konfigurationen"" + [614] Hinweis: Es werden nur die OBIS Kennzahlen übermittelt die für die Bilanzierung relevant sind" + 367,OBIS-Kennzahl der Marktlokation,SG8,PIA,7143,00200,SRW,,OBIS-Kennzahl,X, + 368,Wertegranularität,SG10,,,,,,,Muss [257],[257] Wenn in derselben SG8 SEQ+Z02 (OBIS-Daten der Marktlokation) das PIA+5+1- b?:1.9.e vorhanden + 369,Wertegranularität,SG10,CCI,,00201,,,,Muss, + 370,Wertegranularität,SG10,CCI,7037,00201,ZE4,,Wertegranularität,X, + 371,Wertegranularität,SG10,CAV,,00202,,,,Muss, + 372,Wertegranularität,SG10,CAV,7111,00202,ZD9,,Jährlich,X, + 373,Wertegranularität,SG10,CAV,7111,,ZE8,,Halbjährlich,X, + 374,Wertegranularität,SG10,CAV,7111,,ZE9,,Quartalsweise,X, + 375,Wertegranularität,SG10,CAV,7111,,ZB7,,Monatlich,X, + 376,Zugeordnete Zählzeitdefinition,SG10,,,,,,,Muss [386] ∧[387],[386] Wenn mehr als eine SG8 SEQ+Z02 (OBIS-Daten der Marktlokation) mit einer OBIS-Kennzahl für Energiemenge im PIA+5 vorhanden + 377,Zugeordnete Zählzeitdefinition,SG10,CCI,,00203,,,,Muss, + 378,Zugeordnete Zählzeitdefinition,SG10,CCI,7059,00203,Z39,,Code derZählzeitdefinition,X, + 379,Zugeordnete Zählzeitdefinition,SG10,CCI,7037,00203,,,Code der Zählzeitdefinition,X, + 380,Zugeordnetes Zählzeitregister ,SG10,,,,,,,Muss [421],[421] Wenn in dieser SG8 das SG10 CCI+Z39 (Zugeordnete Zählzeitdefinition) vorhanden ist + 381,Zugeordnetes Zählzeitregister ,SG10,CCI,,00204,,,,Muss, + 382,Zugeordnetes Zählzeitregister ,SG10,CCI,7059,00204,Z38,,Code desZählzeitregisters,X, + 383,Zugeordnetes Zählzeitregister ,SG10,CCI,7037,00204,,,Code des Zählzeitregisters,X, + 384,OBIS Daten für Lieferant relevant,SG10,,,,,,,Muss, + 385,OBIS Daten für Lieferant relevant,SG10,CCI,,00207,,,,Muss, + 386,OBIS Daten für Lieferant relevant,SG10,CCI,7037,00207,ZA7,,LF,X, + 387,Verwendungszweck der Werte,SG10,CAV,,00208,,,,Muss, + 388,Verwendungszweck der Werte,SG10,CAV,7111,00208,Z84,,Netznutzungsabrechnun,X [29P0..1] ⊻g[32P0..1] ⊻[36P0..1], + 389,Verwendungszweck der Werte,SG10,CAV,7111,,Z85,,Bilanzkreisabrechnung,X [31P1..1] ⊻[32P1..1], + 390,Verwendungszweck der Werte,SG10,CAV,7111,,Z86,,Mehrmindermengenabrechnung,X [30P1..1], + 391,Verwendungszweck der Werte,SG10,CAV,7111,,Z47,,Endkundenabrechnung,X [28P0..1] ⊻[29P1..1] ⊻[30P0..1] ⊻[32P1..1] ⊻[36P0..1], + 392,Verwendungszweck der Werte,SG10,CAV,7111,,ZD1,,Blindarbeitabrechnung /Betriebsführung,X [28P0..1], + 393,OBIS Daten für Übertragungsnetzbetreiber relevant,SG10,,,,,,,, + 394,OBIS Daten für Übertragungsnetzbetreiber relevant,SG10,CCI,,00209,,,,, + 395,OBIS Daten für Übertragungsnetzbetreiber relevant,SG10,CCI,7037,00209,ZA9,,ÜNB,, + 396,Verwendungszweck der Werte,SG10,CAV,,00210,,,,, + 397,Verwendungszweck der Werte,SG10,CAV,7111,00210,Z85,,Bilanzkreisabrechnung,, + 398,Verwendungszweck der Werte,SG10,CAV,7111,,ZB5,,Zur Ermittlung derAusgeglichenheit vonBilanzkreisen,, + 399,Produkt-Daten der Marktlokation,SG8,,,,,,,Soll [166],[166] Wenn vorhanden + 400,Produkt-Daten der Marktlokation,SG8,SEQ,,00211,,,,Muss, + 401,Produkt-Daten der Marktlokation,SG8,SEQ,1229,00211,Z59,,Produkt-Daten derMarktlokation,X, + 402,Referenz auf die ID der Marktlokation,SG8,RFF,,00212,,,,Muss, + 403,Referenz auf die ID der Marktlokation,SG8,RFF,1153,00212,Z18,,Marktlokation,X, + 404,Referenz auf die ID der Marktlokation,SG8,RFF,1154,00212,,,ID einer Marktlokation,X [950],[950] Format: Marktlokations-ID + 405,Produkt-Daten der Marktlokation,SG8,PIA,,00213,,,,Muss, + 406,Produkt-Daten der Marktlokation,SG8,PIA,4347,00213,5,,Produktidentifikation,X, + 407,Produkt-Daten der Marktlokation,SG8,PIA,7140,00213,,,Produkt-/Leistungsnummer,X, + 408,Produkt-Daten der Marktlokation,SG8,PIA,7143,00213,Z12,,Konfigurationsprodukt,X, + 409,Zugeordnete Definition,SG10,,,,,,,Muss, + 410,Zugeordnete Definition,SG10,CCI,,00214,,,,Muss, + 411,Zugeordnete Definition,SG10,CCI,7059,00214,Z53,,Code derLeistungskurvendefinition,X, + 412,Zugeordnete Definition,SG10,CCI,7037,00214,,,Code der Definition,X, + 413,Produkt-Daten für Marktrolle relevant,SG10,,,,,,,Muss, + 414,Produkt-Daten für Marktrolle relevant,SG10,CCI,,00215,,,,Muss, + 415,Produkt-Daten für Marktrolle relevant,SG10,CCI,7037,00215,ZA7,,LF,X, + 416,Verbrauchsart und Nutzung der OBIS-Kennzahl der Marktlokation,SG8,,,,,,,Muss [298],[298] Wenn SG5 LOC+Z20 (Technische Ressource) nicht vorhanden + 417,Verbrauchsart und Nutzung der OBIS-Kennzahl der Marktlokation,SG8,SEQ,,00216,,,,Muss, + 418,Verbrauchsart und Nutzung der OBIS-Kennzahl der Marktlokation,SG8,SEQ,1229,00216,Z44,,Verbrauchsart und,X, + 419,Referenz auf die OBIS- Kennzahl der Marktlokation,SG8,RFF,,00217,,,,Muss, + 420,Referenz auf die OBIS- Kennzahl der Marktlokation,SG8,RFF,1153,00217,Z10,,OBIS-Kennzahl,X, + 421,Referenz auf die OBIS- Kennzahl der Marktlokation,SG8,RFF,1154,00217,,,OBIS-Kennzahl,X, + 422,Verbrauchsart und Nutzung an der OBIS-Kennzahl der Marktlokation,SG10,,,,,,,Muss, + 423,Verbrauchsart und Nutzung an der OBIS-Kennzahl der Marktlokation,SG10,CCI,,00218,,,,Muss, + 424,Verbrauchsart und Nutzung an der OBIS-Kennzahl der Marktlokation,SG10,CCI,7059,00218,Z17,,Stromverbrauchsart,X, + 425,Verbrauchsart,SG10,CAV,,00219,,,,Muss, + 426,Verbrauchsart,SG10,CAV,7111,00219,Z64,,Kraft/Licht,X [1P0..1], + 427,Verbrauchsart,SG10,CAV,7111,,Z65,,Wärme,X [1P0..1], + 428,Verbrauchsart,SG10,CAV,7111,,ZE5,,E-Mobilität,X [1P0..1], + 429,Verbrauchsart,SG10,CAV,7111,,ZA8,,Straßenbeleuchtung,X [1P0..1], + 430,Verbrauchsart,SG10,CAV,7111,,ZB3,,SteuerungWärmeabgabe,X [1P0..1], + 431,Unterbrechbarkeit,SG10,CAV,,00220,,,,Muss, + 432,Unterbrechbarkeit,SG10,CAV,7111,00220,Z62,,unterbrechbareVerbrauchseinrichtung,X, + 433,Unterbrechbarkeit,SG10,CAV,7111,,Z63,,nicht-unterbrechbareVerbrauchseinrichtung,X, + 434,Wärmenutzung,SG10,CAV,,00221,,,,Muss [239],[239] Wenn in derselben SG10 das CCI+Z17 (Stromverbrauchsart) im CAV+Z65 (Wärme) vorhanden + 435,Wärmenutzung,SG10,CAV,7111,00221,Z56,,Speicherheizung,X, + 436,Wärmenutzung,SG10,CAV,7111,,Z57,,Wärmepumpe,X, + 437,Wärmenutzung,SG10,CAV,7111,,Z61,,Direktheizung,X, + 438,Art der E-Mobilität,SG10,CAV,,00222,,,,Muss [95],[95] Wenn in derselben SG10 das CCI+Z17 (Stromverbrauchsart) CAV+ZE5 (E-Mobilität) vorhanden + 439,Art der E-Mobilität,SG10,CAV,7111,00222,ZE6,,Wallbox,X, + 440,Art der E-Mobilität,SG10,CAV,7111,,Z87,,E-Mobilitätsladesäule,X, + 441,Art der E-Mobilität,SG10,CAV,7111,,ZE7,,Ladepark,X, + 442,Daten der Tranche,SG8,,,,,,,,"[54] Wenn SG8 SEQ+Z01 (Daten der Marktlokation) SG10 CCI+Z30++Z06 (Lieferrichtung: Erzeugung) vorhanden + [607] Hinweis: In diesem Segment bzw. SG sind die zwischen LF und NB im Rahmen der Marktkommunikation ausgetauschten Daten aus der Sicht des NB anzugeben + [2307] Für jede ID im SG5 LOC+Z21 (Tranche) DE3225 genau einmal anzugeben" + 443,Daten der Tranche,SG8,SEQ,,00238,,,,, + 444,Daten der Tranche,SG8,SEQ,1229,00238,Z15,,Daten der Tranche,, + 445,Referenz auf die ID der Tranche,SG8,RFF,,00239,,,,, + 446,Referenz auf die ID der Tranche,SG8,RFF,1153,00239,Z20,,Tranche,, + 447,Referenz auf die ID der Tranche,SG8,RFF,1154,00239,,,ID der Tranche,,[950] Format: Marktlokations-ID + 448,Prozentualer Anteil der Tranche an der erzeugenden Marktlokation,SG9,,,,,,,,[384] Wenn SG10 CCI+Z37++ZD1 (Basis zur Bildung der Tranchengröße) (Prozentual) vorhanden + 449,Prozentualer Anteil der Tranche an der erzeugenden Marktlokation,SG9,QTY,,00242,,,,, + 450,Prozentualer Anteil der Tranche an der erzeugenden Marktlokation,SG9,QTY,6063,00242,11,,Aufteilungsmenge,, + 451,Prozentualer Anteil der Tranche an der erzeugenden Marktlokation,SG9,QTY,6060,00242,,,Mengenangabe in %,,"[914] Format: Möglicher Wert: > 0 + [930] Format: max. 2 Nachkommastellen + [955] Format: Möglicher Wert: < 100" + 452,Prozentualer Anteil der Tranche an der erzeugenden Marktlokation,SG9,QTY,6411,00242,P1,,Prozent,, + 453,Zugeordnete Marktpartner,SG10,,,,,,,, + 454,Zugeordnete Marktpartner,SG10,CCI,,00243,,,,, + 455,Zugeordnete Marktpartner,SG10,CCI,7037,00243,ZB3,,ZugeordneterMarktpartner,, + 456,Lieferant,SG10,CAV,,00244,,,,, + 457,Lieferant,SG10,CAV,7111,00244,Z89,,LF,, + 458,Lieferant,SG10,CAV,1131,00244,,,MP-ID,, + 459,Bilanzkreis,SG10,,,,,,,, + 460,Bilanzkreis,SG10,CCI,,00245,,,,, + 461,Bilanzkreis,SG10,CCI,7059,00245,Z19,,Bilanzkreis,, + 462,Bilanzkreis,SG10,CCI,7037,00245,,,Bilanzkreis,, + 463,Basis zur Bildung der Tranchengröße,SG10,,,,,,,, + 464,Basis zur Bildung der Tranchengröße,SG10,CCI,,00248,,,,, + 465,Basis zur Bildung der Tranchengröße,SG10,CCI,7059,00248,Z37,,Basis zur Bildung derTranchengröße,, + 466,Basis zur Bildung der Tranchengröße,SG10,CCI,7037,00248,ZD1,,Prozentual,, + 467,Basis zur Bildung der Tranchengröße,SG10,CCI,7037,,ZD2,,Aufteilungsfaktor aufBasis vonReferenzenträger/installierter Leistung,, + 468,OBIS-Daten der Tranche,SG8,,,,,,,,"[607] Hinweis: In diesem Segment bzw. SG sind die zwischen LF und NB im Rahmen der Marktkommunikation ausgetauschten Daten aus der Sicht des NB anzugeben + [2311] Für jede ID im SG5 LOC+Z21 (Tranche) DE3225, mindestens einmal anzugeben" + 469,OBIS-Daten der Tranche,SG8,SEQ,,00260,,,,, + 470,OBIS-Daten der Tranche,SG8,SEQ,1229,00260,Z17,,OBIS-Daten der Tranche,, + 471,Referenz auf die ID einer Tranche,SG8,RFF,,00261,,,,, + 472,Referenz auf die ID einer Tranche,SG8,RFF,1153,00261,Z20,,Tranche,, + 473,Referenz auf die ID einer Tranche,SG8,RFF,1154,00261,,,ID einer Tranche,,[950] Format: Marktlokations-ID + 474,OBIS-Kennzahl der Tranche,SG8,PIA,,00262,,,,, + 475,OBIS-Kennzahl der Tranche,SG8,PIA,4347,00262,5,,Produktidentifikation,, + 476,OBIS-Kennzahl der Tranche,SG8,PIA,7140,00262,,,OBIS-Kennzahl der Tranche,,[269] Es sind alle OBIS- Kennzahlen gem. EDI@Energy Codeliste der OBIS-Kennzahlen und Medien für den deutschen Energiemarkt Kap.3 anzugeben welche an der Tranche erforderlich sind + 477,OBIS-Kennzahl der Tranche,SG8,PIA,7143,00262,SRW,,OBIS-Kennzahl,, + 478,OBIS Daten für Übertragungsnetzbetreiber relevant,SG10,,,,,,,, + 479,OBIS Daten für Übertragungsnetzbetreiber relevant,SG10,CCI,,00267,,,,, + 480,OBIS Daten für Übertragungsnetzbetreiber relevant,SG10,CCI,7037,00267,ZA9,,ÜNB,, + 481,Verwendungszweck der Werte,SG10,CAV,,00268,,,,, + 482,Verwendungszweck der Werte,SG10,CAV,7111,00268,Z85,,Bilanzkreisabrechnung,, + 483,Verwendungszweck der Werte,SG10,CAV,7111,,ZB5,,Zur Ermittlung derAusgeglichenheit vonBilanzkreisen,, + 484,Daten der Technischen Ressource,SG8,,,,,,,Muss [296] ∧[2357],"[296] Wenn SG5 LOC+Z20 (Technische Ressource) vorhanden + [2357] Je SG5 LOC+Z20 (Technische Ressource) ist genau einmal die Segmentgruppe anzugeben" + 485,Daten der Technischen Ressource,SG8,SEQ,,00273,,,,Muss, + 486,Daten der Technischen Ressource,SG8,SEQ,1229,00273,Z52,,Daten der TechnischenRessource,X, + 487,Referenz auf die ID der Technischen Ressource,SG8,RFF,,00274,,,,Muss, + 488,Referenz auf die ID der Technischen Ressource,SG8,RFF,1153,00274,Z37,,Technische Ressource,X, + 489,Referenz auf die ID der Technischen Ressource,SG8,RFF,1154,00274,,,ID der Technischen Ressource,X [922],[922] Format: TR-ID + 490,Referenz auf die ID der vorgelagerten Messlokation,SG8,RFF,,00275,,,,Soll [166] ∧[668],"[166] Wenn vorhanden + [668] Hinweis: Dieses Segment wird nach Abschluss der Einführung der Lokationsbündelstruktur zum 01.10.2025 aus der UTILMD entfernt" + 491,Referenz auf die ID der vorgelagerten Messlokation,SG8,RFF,1153,00275,Z34,,vorgelagerteMesslokation,X, + 492,Referenz auf die ID der vorgelagerten Messlokation,SG8,RFF,1154,00275,,,ID einer Lokation,X [951],[951] Format: Zählpunktbezeichnung + 493,Referenz auf die der Technischen Ressource zugeordneten Marktlokation,SG8,RFF,,00276,,,,Muss [668],[668] Hinweis: Dieses Segment wird nach Abschluss der Einführung der Lokationsbündelstruktur zum 01.10.2025 aus der UTILMD entfernt + 494,Referenz auf die der Technischen Ressource zugeordneten Marktlokation,SG8,RFF,1153,00276,Z16,,zugeordneteMarktlokation,X, + 495,Referenz auf die der Technischen Ressource zugeordneten Marktlokation,SG8,RFF,1154,00276,,,ID der Marktlokation,X [950],[950] Format: Marktlokations-ID + 496,Referenz auf die der Technischen Ressource zugeordneten Steuerbaren Ressource,SG8,RFF,,00277,,,,Soll [166] ∧[699],"[166] Wenn vorhanden + [699] Hinweis: Es ist die ID der Steuerbare Ressource zu nennen über die die Technische Ressource gesteuert wird" + 497,Referenz auf die der Technischen Ressource zugeordneten Steuerbaren Ressource,SG8,RFF,1153,00277,Z38,,Steuerbare Ressource,X, + 498,Referenz auf die der Technischen Ressource zugeordneten Steuerbaren Ressource,SG8,RFF,1154,00277,,,ID der Steuerbaren Ressource,X [961],[961] Format: SR-ID + 499,Referenz auf die der Technischen Ressource zugeordneten Netzlokation,SG8,RFF,,00278,,,,Soll [166] ∧[700],"[166] Wenn vorhanden + [700] Hinweis: Es ist die ID der Netzlokation zu nennen über die die Technische Ressource gesteuert wird" + 500,Referenz auf die der Technischen Ressource zugeordneten Netzlokation,SG8,RFF,1153,00278,Z32,,Netzlokation,X, + 501,Referenz auf die der Technischen Ressource zugeordneten Netzlokation,SG8,RFF,1154,00278,,,ID der Netzlokation,X [960],[960] Format: Netzlokations- ID + 502,Nennleistung (Aufnahme),SG9,,,,,,,Muss ([446] ∧([465] ∨ [466])∧ [467] ∧ ([468]⊻ ([469] ∧[470]))) ⊻ [448]Soll [165],"[165] Wenn bekannt + [446] Wenn in derselben SG8 das CCI+Z17 (Stromverbrauchsart) vorhanden + [448] Wenn in derselben SG8 das CCI+Z56 (Speicher) vorhanden" + 503,Nennleistung (Aufnahme),SG9,QTY,,00279,,,,Muss, + 504,Nennleistung (Aufnahme),SG9,QTY,6063,00279,Z43,,Nennleistung(Aufnahme),X, + 505,Nennleistung (Aufnahme),SG9,QTY,6060,00279,,,Menge,X, + 506,Nennleistung (Aufnahme),SG9,QTY,6411,00279,KWT,,Kilowatt,X, + 507,Nennleistung (Abgabe),SG9,,,,,,,Muss [448],[448] Wenn in derselben SG8 das CCI+Z56 (Speicher) vorhanden + 508,Nennleistung (Abgabe),SG9,QTY,,00280,,,,Muss, + 509,Nennleistung (Abgabe),SG9,QTY,6063,00280,Z44,,Nennleistung (Abgabe),X, + 510,Nennleistung (Abgabe),SG9,QTY,6060,00280,,,Menge,X, + 511,Nennleistung (Abgabe),SG9,QTY,6411,00280,KWT,,Kilowatt,X, + 512,Speicherkapazität,SG9,,,,,,,Muss [448],[448] Wenn in derselben SG8 das CCI+Z56 (Speicher) vorhanden + 513,Speicherkapazität,SG9,QTY,,00281,,,,Muss, + 514,Speicherkapazität,SG9,QTY,6063,00281,Z42,,Speicherkapazität,X, + 515,Speicherkapazität,SG9,QTY,6060,00281,,,Menge,X, + 516,Speicherkapazität,SG9,QTY,6411,00281,KWH,,Kilowattstunde,X, + 517,Art und Nutzung der Technischen Ressource,SG10,,,,,,,Muss, + 518,Art und Nutzung der Technischen Ressource,SG10,CCI,,00282,,,,Muss, + 519,Art und Nutzung der Technischen Ressource,SG10,CCI,7059,00282,Z17,,Stromverbrauchsart,X, + 520,Art und Nutzung der Technischen Ressource,SG10,CCI,7059,,Z56,,Speicher,X, + 521,Verbrauchsart,SG10,CAV,,00283,,,,Muss [446],[446] Wenn in derselben SG8 das CCI+Z17 (Stromverbrauchsart) vorhanden + 522,Verbrauchsart,SG10,CAV,7111,00283,Z64,,Kraft/Licht,X [1P0..1], + 523,Verbrauchsart,SG10,CAV,7111,,Z65,,Wärme,X [1P0..1], + 524,Verbrauchsart,SG10,CAV,7111,,ZE5,,E-Mobilität,X [1P0..1], + 525,Verbrauchsart,SG10,CAV,7111,,ZA8,,Straßenbeleuchtung,X [1P0..1], + 526,Wärmenutzung,SG10,CAV,,00284,,,,Muss [239],[239] Wenn in derselben SG10 das CCI+Z17 (Stromverbrauchsart) im CAV+Z65 (Wärme) vorhanden + 527,Wärmenutzung,SG10,CAV,7111,00284,Z56,,Speicherheizung,X, + 528,Wärmenutzung,SG10,CAV,7111,,Z57,,Wärmepumpe,X, + 529,Wärmenutzung,SG10,CAV,7111,,Z61,,Direktheizung,X, + 530,Art der E-Mobilität,SG10,CAV,,00285,,,,Muss [95],[95] Wenn in derselben SG10 das CCI+Z17 (Stromverbrauchsart) CAV+ZE5 (E-Mobilität) vorhanden + 531,Art der E-Mobilität,SG10,CAV,7111,00285,ZE6,,Wallbox,X, + 532,Art der E-Mobilität,SG10,CAV,7111,,Z87,,E-Mobilitätsladesäule,X, + 533,Art der E-Mobilität,SG10,CAV,7111,,ZE7,,Ladepark,X, + 534,Speicherart,SG10,CAV,,00287,,,,Muss [448],[448] Wenn in derselben SG8 + 535,Speicherart,SG10,CAV,7111,00287,ZF7,,Wasserstoffspeicher,X, + 536,Speicherart,SG10,CAV,7111,,ZF8,,Pumpspeicher,X, + 537,Speicherart,SG10,CAV,7111,,ZF9,,Batteriespeicher,X, + 538,Speicherart,SG10,CAV,7111,,ZG6,,Sonstige Speicherart,X, + 539,Kategorie der verbrauchenden Technischen Ressource,SG10,CAV,,00288,,,,Muss [446] ⊻[448],"[446] Wenn in derselben SG8 das CCI+Z17 (Stromverbrauchsart) vorhanden + [448] Wenn in derselben SG8 das CCI+Z56 (Speicher) vorhanden" + 540,Kategorie der verbrauchenden Technischen Ressource,SG10,CAV,7111,00288,ZG8,,Technischen Ressourcefällt unter § 14a EnWG,X, + 541,Kategorie der verbrauchenden Technischen Ressource,SG10,CAV,7111,,ZG9,,Technischen Ressourcefällt nicht unter § 14aEnWG,X, + 542,Inbetriebsetzungsdatum der verbrauchenden Technischen Ressource nach § 14a EnWG,SG10,CAV,,00289,,,,Muss [461],[461] Wenn in derselben SG10 das CCI+Z17 (Stromverbrauchsart) im CAV+ZG8 (Technischen Ressource fällt unter § 14a EnWG) vorhanden + 543,Inbetriebsetzungsdatum der verbrauchenden Technischen Ressource nach § 14a EnWG,SG10,CAV,7111,00289,ZH0,,Inbetriebsetzung der TRnach 2023,X, + 544,Inbetriebsetzungsdatum der verbrauchenden Technischen Ressource nach § 14a EnWG,SG10,CAV,7111,,ZH1,,Inbetriebsetzung der TRvor 2024,X, + 545,Einordnung der verbrauchenden Technischen Ressource nach § 14a EnWG mit Inbetriebsetzung vor 2024,SG10,CAV,,00290,,,,Muss [462],[462] Wenn in derselben SG10 das CCI+Z17 (Stromverbrauchsart) im CAV+ZH1 (Inbetriebsetzung der TR vor 2024) vorhanden + 546,Einordnung der verbrauchenden Technischen Ressource nach § 14a EnWG mit Inbetriebsetzung vor 2024,SG10,CAV,7111,00290,ZH2,,Wechselmöglichkeit indas § 14a EnWG-Modellgem. Festlegung BK6-,X, + 547,Information zu weiteren technischen Einrichtungen,SG10,,,,,,,Muss [446] ∧[467],"[446] Wenn in derselben SG8 das CCI+Z17 (Stromverbrauchsart) vorhanden + [467] Wenn in derselben SG8 SEQ+Z52 (Daten der Technischen Ressource) das CAV+ZG8 (Technischen Ressource fällt unter §14a EnWG) vorhanden ist" + 548,Information zu weiteren technischen Einrichtungen,SG10,CCI,,00291,,,,Muss, + 549,Information zu weiteren technischen Einrichtungen,SG10,CCI,7059,00291,Z63,,Information zu weiterentechnischenEinrichtungen,X, + 550,Information zu weiteren technischen Einrichtungen,SG10,CAV,,00292,,,,Muss, + 551,Information zu weiteren technischen Einrichtungen,SG10,CAV,7111,00292,ZH7,,Weitere technischeEinrichtungen vorhanden,X, + 552,Information zu weiteren technischen Einrichtungen,SG10,CAV,7111,,ZH8,,Keine weitere technischeEinrichtung vorhanden,X, + 553,Daten der Steuerbaren Ressource,SG8,,,,,,,Muss [205] ∧[2358],"[205] Wenn SG5 LOC+Z19 (Steuerbare Ressource) vorhanden + [2358] Je SG5 LOC+Z19 (Steuerbare Ressource) ist genau einmal die Segmentgruppe anzugeben" + 554,Daten der Steuerbaren Ressource,SG8,SEQ,,00293,,,,Muss, + 555,Daten der Steuerbaren Ressource,SG8,SEQ,1229,00293,Z62,,Daten der SteuerbarenRessource,X, + 556,Referenz auf die ID der Steuerbaren Ressource,SG8,RFF,,00294,,,,Muss, + 557,Referenz auf die ID der Steuerbaren Ressource,SG8,RFF,1153,00294,Z38,,Steuerbare Ressource,X, + 558,Referenz auf die ID der Steuerbaren Ressource,SG8,RFF,1154,00294,,,ID der Steuerbaren Ressource,X [961],[961] Format: SR-ID + 559,Steuerkanal,SG10,,,,,,,Muss, + 560,Steuerkanal,SG10,CCI,,00295,,,,Muss, + 561,Steuerkanal,SG10,CCI,7059,00295,Z49,,Steuerkanal,X, + 562,Leistungsbeschreibung des Steuerkanals,SG10,CAV,,00296,,,,Muss, + 563,Leistungsbeschreibung des Steuerkanals,SG10,CAV,7111,00296,ZF2,,Leistungsbeschreibungdes Steuerkanals,X, + 564,Leistungsbeschreibung des Steuerkanals,SG10,CAV,1131,00296,Z14,,An/Aus,X, + 565,Leistungsbeschreibung des Steuerkanals,SG10,CAV,1131,,Z15,,Gestuft,X, + 566,Zugeordnete Marktpartner,SG10,,,,,,,Muss, + 567,Zugeordnete Marktpartner,SG10,CCI,,00297,,,,Muss, + 568,Zugeordnete Marktpartner,SG10,CCI,7037,00297,ZB3,,ZugeordneterMarktpartner,X, + 569,Messstellenbetreiber,SG10,CAV,,00298,,,,Muss, + 570,Messstellenbetreiber,SG10,CAV,7111,00298,Z91,,MSB,X, + 571,Messstellenbetreiber,SG10,CAV,1131,00298,,,MP-ID,X, + 572,Messstellenbetreiber,SG10,CAV,7110,00298,Z39,,GrundzuständigerMessstellenbetreiber,X, + 573,Messstellenbetreiber,SG10,CAV,7110,,Z40,,WettbewerblicherMessstellenbetreiber,X, + 574,Messstellenbetreiber,SG10,CAV,7110,,Z41,,Auffangmessstellenbetreiber,X, + 575,Produkt-Daten der Steuerbaren Ressource,SG8,,,,,,,Soll [166] ∧[205],"[166] Wenn vorhanden + [205] Wenn SG5 LOC+Z19 (Steuerbare Ressource) vorhanden" + 576,Produkt-Daten der Steuerbaren Ressource,SG8,SEQ,,00299,,,,Muss, + 577,Produkt-Daten der Steuerbaren Ressource,SG8,SEQ,1229,00299,Z61,,Produkt-Daten derSteuerbaren Ressource,X, + 578,Referenz auf die ID der Steuerbaren Ressource,SG8,RFF,,00300,,,,Muss, + 579,Referenz auf die ID der Steuerbaren Ressource,SG8,RFF,1153,00300,Z38,,Steuerbare Ressource,X, + 580,Referenz auf die ID der Steuerbaren Ressource,SG8,RFF,1154,00300,,,ID einer Steuerbaren Ressource,X [961],[961] Format: SR-ID + 581,Produkt-Daten der Steuerbaren Ressource,SG8,PIA,,00301,,,,Muss, + 582,Produkt-Daten der Steuerbaren Ressource,SG8,PIA,4347,00301,5,,Produktidentifikation,X, + 583,Produkt-Daten der Steuerbaren Ressource,SG8,PIA,7140,00301,,,Konfigurationsprodukt-Code,X, + 584,Produkt-Daten der Steuerbaren Ressource,SG8,PIA,7143,00301,Z12,,Konfigurationsprodukt,X, + 585,Zugeordnete Definition,SG10,,,,,,,Muss, + 586,Zugeordnete Definition,SG10,CCI,,00302,,,,Muss, + 587,Zugeordnete Definition,SG10,CCI,7059,00302,Z52,,Code derSchaltzeitdefinition,X, + 588,Zugeordnete Definition,SG10,CCI,7059,,Z53,,Code derLeistungskurvendefinition,X, + 589,Zugeordnete Definition,SG10,CCI,7037,00302,,,Code der Definition,X, + 590,Auftraggebender Marktpartner,SG10,,,,,,,Muss, + 591,Auftraggebender Marktpartner,SG10,CCI,,00303,,,,Muss, + 592,Auftraggebender Marktpartner,SG10,CCI,7037,00303,ZB3,,ZugeordneterMarktpartner,X, + 593,Auftraggebender Marktpartner,SG10,CAV,,00304,,,,Muss, + 594,Auftraggebender Marktpartner,SG10,CAV,7111,00304,Z88,,NB,X, + 595,Auftraggebender Marktpartner,SG10,CAV,7111,,Z89,,LF,X, + 596,Auftraggebender Marktpartner,SG10,CAV,1131,00304,,,MP-ID,X, + 597,Produkt-Daten für Marktrolle relevant,SG10,,,,,,,Muss, + 598,Produkt-Daten für Marktrolle relevant,SG10,CCI,,00305,,,,Muss, + 599,Produkt-Daten für Marktrolle relevant,SG10,CCI,7037,00305,ZA7,,LF,X, + 600,Daten der Messlokation,SG8,,,,,,,Muss [2284],[2284] Für jede Messlokations-ID im SG5 LOC+Z17 (Messlokation) DE3225 genau einmal anzugeben + 601,Daten der Messlokation,SG8,SEQ,,00306,,,,Muss, + 602,Daten der Messlokation,SG8,SEQ,1229,00306,Z18,,Daten der Messlokation,X, + 603,Referenz auf die ID der Messlokation,SG8,RFF,,00307,,,,Muss, + 604,Referenz auf die ID der Messlokation,SG8,RFF,1153,00307,Z19,,Messlokation,X, + 605,Referenz auf die ID der Messlokation,SG8,RFF,1154,00307,,,ID der Messlokation,X [951],[951] Format: + 606,Abrechnung des Messstellenbetriebs über NNE für kME,SG8,RFF,,00309,,,,Muss [235],"[235] Wenn das RFF+Z19 (Messlokation) aus dieser SG8 auf das gleiche SG5 LOC+Z17 (Messlokation), wie ein RFF+Z19 (Messlokation) aus einer SG8 SEQ+Z03 (Zähleinrichtungsdaten), in dem SG10 CCI+++E13 CAV+MME (Zählertyp: mME) nicht vorhanden ist, referenziert" + 607,Abrechnung des Messstellenbetriebs über NNE für kME,SG8,RFF,1153,00309,Z05,,Abrechnung desMessstellenbetriebs überNNE für kME,X, + 608,Abrechnung des Messstellenbetriebs über NNE für kME,SG8,RFF,1154,00309,,,Abrechnung über NNE (Ja/Nein),X, + 609,Zugeordnete Marktpartner,SG10,,,,,,,Muss, + 610,Zugeordnete Marktpartner,SG10,CCI,,00310,,,,Muss, + 611,Zugeordnete Marktpartner,SG10,CCI,7037,00310,ZB3,,ZugeordneterMarktpartner,X, + 612,Messstellenbetreiber,SG10,CAV,,00311,,,,Muss, + 613,Messstellenbetreiber,SG10,CAV,7111,00311,Z91,,MSB,X, + 614,Messstellenbetreiber,SG10,CAV,1131,00311,,,MP-ID,X, + 615,Messstellenbetreiber,SG10,CAV,7110,00311,Z19,,Auf vertraglicherGrundlage gegenüberAnschlussnutzer /Anschlussnehmer,X, + 616,Messstellenbetreiber,SG10,CAV,7110,,Z20,,In der Ausübung derWeiterverpflichtungdurch den gMSB,X, + 617,Messstellenbetreiber,SG10,CAV,7110,00311,Z39,,GrundzuständigerMessstellenbetreiber,X, + 618,Messstellenbetreiber,SG10,CAV,7110,,Z40,,WettbewerblicherMessstellenbetreiber,X, + 619,Messstellenbetreiber,SG10,CAV,7110,,Z41,,Auffangmessstellenbetreiber,X, + 620,Grundzuständiger Messstellenbetreiber,SG10,CAV,,00312,,,,Muss, + 621,Grundzuständiger Messstellenbetreiber,SG10,CAV,7111,00312,ZF0,,gMSB,X, + 622,Grundzuständiger Messstellenbetreiber,SG10,CAV,1131,00312,,,MP-ID,X, + 623,Spannungsebene der Messlokation,SG10,,,,,,,Muss, + 624,Spannungsebene der Messlokation,SG10,CCI,,00314,,,,Muss, + 625,Spannungsebene der Messlokation,SG10,CCI,7037,00314,E04,,Spannungsebene derMesslokation,X, + 626,Spannungsebene der Messlokation,SG10,CAV,,00315,,,,Muss, + 627,Spannungsebene der Messlokation,SG10,CAV,7111,00315,E03,,Höchstspannung,X, + 628,Spannungsebene der Messlokation,SG10,CAV,7111,,E04,,Hochspannung,X, + 629,Spannungsebene der Messlokation,SG10,CAV,7111,,E05,,Mittelspannung,X, + 630,Spannungsebene der Messlokation,SG10,CAV,7111,,E06,,Niederspannung,X, + 631,Zähleinrichtungsdaten,SG8,,,,,,,Muss [2286],[2286] Für jede SEQ+Z18 (Daten der Messlokation) mindestens einmal anzugeben + 632,Zähleinrichtungsdaten,SG8,SEQ,,00326,,,,Muss, + 633,Zähleinrichtungsdaten,SG8,SEQ,1229,00326,Z03,,Zähleinrichtungsdaten,X, + 634,Referenz auf die ID einer Messlokation,SG8,RFF,,00327,,,,Muss, + 635,Referenz auf die ID einer Messlokation,SG8,RFF,1153,00327,Z19,,Messlokation,X, + 636,Referenz auf die ID einer Messlokation,SG8,RFF,1154,00327,,,ID einer Messlokation,X [951],[951] Format: Zählpunktbezeichnung + 637,Referenz auf das Smartmeter-Gateway,SG8,RFF,,00328,,,,Soll [166] ∧[215],"[166] Wenn vorhanden + [215] Wenn in derselben SG8 SEQ+Z03 (Zähleinrichtungsdaten) SG10 CCI+++E13 CAV+MME (Zählertyp: mME) vorhanden" + 638,Referenz auf das Smartmeter-Gateway,SG8,RFF,1153,00328,Z14,,Smartmeter-Gateway,X, + 639,Referenz auf das Smartmeter-Gateway,SG8,RFF,1154,00328,,,Identifikation / Nummer desSmartmeter-Gateways,X, + 640,Zählertyp,SG10,,,,,,,Muss, + 641,Zählertyp,SG10,CCI,,00329,,,,Muss, + 642,Zählertyp,SG10,CCI,7037,00329,E13,,Zählertyp,X, + 643,Zählertyp,SG10,CAV,,00330,,,,Muss, + 644,Zählertyp,SG10,CAV,7111,00330,AHZ,,analoger Haushaltszähler(Drehstrom),X, + 645,Zählertyp,SG10,CAV,7111,,WSZ,,analogerWechselstromzähler,X, + 646,Zählertyp,SG10,CAV,7111,,LAZ,,Lastgangzähler,X, + 647,Zählertyp,SG10,CAV,7110,00330,Z01,,EDL40,X [136], + 648,Zählertyp,SG10,CAV,7110,,Z02,,EDL21,X [136], + 649,Zählertyp,SG10,CAV,7110,,Z03,,sonstiger EHZ,X [136], + 650,Zählertyp,SG10,CAV,7110,,Z04,,Standard,X [346], + 651,Zählertyp,SG10,CAV,7110,,Z05,,MeDa-Zähler,X [346],"[136] Wenn SG10 CCI+++E13 (Zählertyp) CAV+EHZ (elektronischer Haushaltszähler) vorhanden + [346] Wenn SG10 CCI+++E13 (Zählertyp) CAV+MME (mME) vorhanden" + 652,Identifikation / Nummer des Gerätes,SG10,CAV,,00331,,,,Muss, + 653,Identifikation / Nummer des Gerätes,SG10,CAV,7111,00331,Z30,,Gerätenummer,X, + 654,Identifikation / Nummer des Gerätes,SG10,CAV,7110,00331,,,Gerätenummer,X, + 655,Registeranzahl,SG10,CAV,,00332,,,,Muss [139],[139] Wenn SG10 CAV+IVA (Individuelle Abstimmung) nicht vorhanden + 656,Registeranzahl,SG10,CAV,7111,00332,ETZ,,Eintarif,X, + 657,Registeranzahl,SG10,CAV,7111,,ZTZ,,Zweitarif,X, + 658,Registeranzahl,SG10,CAV,7111,,NTZ,,Mehrtarif,X, + 659,Energierichtung,SG10,CAV,,00333,,,,Muss, + 660,Energierichtung,SG10,CAV,7111,00333,ERZ,,Einrichtungszähler,X, + 661,Energierichtung,SG10,CAV,7111,,ZRZ,,Zweirichtungszähler,X, + 662,Fernschaltung der Zähleinrichtung,SG10,CAV,,00334,,,,Muss, + 663,Fernschaltung der Zähleinrichtung,SG10,CAV,7111,00334,Z58,,Fernschaltung derZähleinrichtung,X, + 664,Fernschaltung der Zähleinrichtung,SG10,CAV,7110,00334,Z06,,vorhanden,X, + 665,Fernschaltung der Zähleinrichtung,SG10,CAV,7110,,Z07,,nicht vorhanden,X, + 666,Messwerterfassung an der Zähleinrichtung,SG10,,,,,,,Muss [316],[316] Wenn in derselben SG8 das RFF+Z14 (Smartmeter- Gateway) nicht vorhanden + 667,Messwerterfassung an der Zähleinrichtung,SG10,CCI,,00337,,,,Muss, + 668,Messwerterfassung an der Zähleinrichtung,SG10,CCI,7037,00337,E12,,Messwerterfassung ander Zähleinrichtung,X, + 669,Messwerterfassung an der Zähleinrichtung,SG10,CAV,,00338,,,,Muss, + 670,Messwerterfassung an der Zähleinrichtung,SG10,CAV,7111,00338,AMR,,fernauslesbare Zähler,X, + 671,Messwerterfassung an der Zähleinrichtung,SG10,CAV,7111,,MMR,,manuell ausgeleseneZähler,X, + 672,OBIS-Daten der Zähleinrichtung / Smartmeter-Gateway,SG8,,,,,,,Muss ([2287] ∧[121]) ∨ [2350],"[121] Wenn in dem SEQ+Z03 (Zähleinrichtungsdaten) das SG8 RFF+Z14 (Referenz auf das Smartmeter-Gateway) nicht vorhanden + [2287] Für jede SEQ+Z03 (Zähleinrichtungsdaten) mindestens einmal anzugeben + [2350] Für jedes SMGW das im SEQ+Z13 (Smartmeter- Gateway) SG10 CCI+++Z75 CAV+Z30 (Gerätenummer) genannt ist, mindestens einmal je SEQ+Z03 (Zähleinrichtungsdaten) das mit SG8 RFF+Z14 (Referenz auf das Smartmeter-Gateway) auf das SMGW referenziert" + 673,OBIS-Daten der Zähleinrichtung / Smartmeter-Gateway,SG8,SEQ,,00339,,,,Muss, + 674,OBIS-Daten der Zähleinrichtung / Smartmeter-Gateway,SG8,SEQ,1229,00339,Z20,,OBIS-Daten derZähleinrichtung,X, + 675,Referenz auf die Gerätenummer,SG8,RFF,,00340,,,,Muss [665],[665] Hinweis: Wenn ein Zähler mit einem SMGW parametriert ist werden an dem Zähler keine OBIS- Kennzahlen angegeben Hier gibt es nur OBIS Kennzahlen vom SMGW + 676,Referenz auf die Gerätenummer,SG8,RFF,1153,00340,MG,,Gerätenummer desZählers,X [441], + 677,Referenz auf die Gerätenummer,SG8,RFF,1153,,Z14,,Smartmeter-Gateway,X,[441] Wenn im SG8+SEQ+Z03 (Zähleinrichtungsdaten) für die in diesem RFF DE1154 genannte Gerätenummer eines Zählers das RFF+Z14 (Referenz auf das Smartmeter-Gateway) nicht vorhanden ist + 678,Referenz auf die Gerätenummer,SG8,RFF,1154,00340,,,Gerätenummer,X, + 679,Referenz auf die ID einer Messlokation,SG8,RFF,,00341,,,,Muss, + 680,Referenz auf die ID einer Messlokation,SG8,RFF,1153,00341,Z19,,Messlokation,X, + 681,Referenz auf die ID einer Messlokation,SG8,RFF,1154,00341,,,ID einer Messlokation,X [951],[951] Format: Zählpunktbezeichnung + 682,Konfigurations-ID,SG8,RFF,,00343,,,,Muss [402] ∧[420],"[402] Wenn in derselben SG8 SEQ+Z20 (OBIS-Daten der Zähleinrichtung / Smartmeter-Gateway) eine OBIS-Kennzahl der Werteart ""Zählerstand"" im PIA+5 vorhanden + [420] Wenn in dieser SG8 das RFF+Z14 (Smartmeter- Gateway) vorhanden ist" + 683,Konfigurations-ID,SG8,RFF,1153,00343,AGK,,Anwendungsreferenznummer,X, + 684,Konfigurations-ID,SG8,RFF,1154,00343,,,"Referenz, Identifikation",X, + 685,OBIS-Kennzahl der Zähleinrichtung / Smartmeter-Gateway,SG8,PIA,,00344,,,,Muss, + 686,OBIS-Kennzahl der Zähleinrichtung / Smartmeter-Gateway,SG8,PIA,4347,00344,5,,Produktidentifikation,X, + 687,OBIS-Kennzahl der Zähleinrichtung / Smartmeter-Gateway,SG8,PIA,7140,00344,,,OBIS-Kennzahl derZähleinrichtung,X [323],"[323] Es sind alle OBIS- Kennzahlen gem. EDI@Energy Codeliste der OBIS-Kennzahlen und Medien für den deutschen Energiemarkt Kap. 3. anzugeben, welche an der Zähleinrichtung genutzt werden. Der Mindestumfang der OBIS-Kennzahlen ergibt sich aus den genannten Messprodukt-Codes dem Kap. 5.1 des Dokumentes ""Codeliste der Konfigurationen""" + 688,OBIS-Kennzahl der Zähleinrichtung / Smartmeter-Gateway,SG8,PIA,7143,00344,SRW,,OBIS-Kennzahl,X, + 689,Wertegranularität,SG10,,,,,,,Muss [256],[256] Wenn in derselben SG8 SEQ+Z20 (OBIS-Daten der Zähleinrichtung / Smartmeter-Gateway) das PIA+5+1-b?:1.8.e / 1-b?:2.8.e vorhanden + 690,Wertegranularität,SG10,CCI,,00345,,,,Muss, + 691,Wertegranularität,SG10,CCI,7037,00345,ZE4,,Wertegranularität,X, + 692,Wertegranularität,SG10,CAV,,00346,,,,Muss, + 693,Wertegranularität,SG10,CAV,7111,00346,ZD9,,Jährlich,X, + 694,Wertegranularität,SG10,CAV,7111,,ZE8,,Halbjährlich,X, + 695,Wertegranularität,SG10,CAV,7111,,ZE9,,Quartalsweise,X, + 696,Wertegranularität,SG10,CAV,7111,,ZB7,,Monatlich,X, + 697,Zugeordnete Zählzeitdefinition,SG10,,,,,,,Muss [389] ∧[391],"[389] Wenn mehr als eine SG8 SEQ+Z20 (OBIS-Daten der Zähleinrichtung / Smartmeter-Gateway), die mit dem RFF+MG/Z14 (Referenz auf die Gerätenummer) auf die gleiche Gerätenummer referenziert, mit einer OBIS- Kennzahl der Werteart ""Zählerstand"" im PIA+5 vorhanden + [391] Wenn in derselben SG8 SEQ+Z20 (OBIS Daten der Zähleinrichtung / Smartmeter-Gateway) eine OBIS-Kennzahl für Zählerstand im PIA+5 vorhanden und es sich lt. Codeliste OBIS um eine OBIS mit zugeordneter Zählzeit handelt (Tarif: e = 1 .. 62)" + 698,Zugeordnete Zählzeitdefinition,SG10,CCI,,00347,,,,Muss, + 699,Zugeordnete Zählzeitdefinition,SG10,CCI,7059,00347,Z39,,Code derZählzeitdefinition,X, + 700,Zugeordnete Zählzeitdefinition,SG10,CCI,7037,00347,,,Code der Zählzeitdefinition,X, + 701,Zugeordnetes Zählzeitregister ,SG10,,,,,,,Muss [421],[421] Wenn in dieser SG8 das SG10 CCI+Z39 (Zugeordnete Zählzeitdefinition) vorhanden ist + 702,Zugeordnetes Zählzeitregister ,SG10,CCI,,00348,,,,Muss, + 703,Zugeordnetes Zählzeitregister ,SG10,CCI,7059,00348,Z38,,Code desZählzeitregisters,X, + 704,Zugeordnetes Zählzeitregister ,SG10,CCI,7037,00348,,,Code des Zählzeitregisters,X, + 705,Vor- und Nachkommastellen des Zählwerks,SG10,,,,,,,Muss [273],[273] Wenn in derselben SG8 SEQ+Z20 (OBIS-Daten der Zähleinrichtung / Smartmeter-Gateway) das PIA+5+1-b?:1.8.e / 1-b?:2.8.e / + 706,Vor- und Nachkommastellen des Zählwerks,SG10,CCI,,00349,,,,Muss, + 707,Vor- und Nachkommastellen des Zählwerks,SG10,CCI,7059,00349,11,,Produkt,X, + 708,Vor- und Nachkommastellen des Zählwerks,SG10,CCI,7037,00349,Z33,,Vor- undNachkommastellen desZählwerkes,X, + 709,Vor- und Nachkommastellen des Zählwerks,SG10,CAV,,00350,,,,Muss, + 710,Vor- und Nachkommastellen des Zählwerks,SG10,CAV,7110,00350,,,Angabe der Vorkommastelle,X, + 711,Vor- und Nachkommastellen des Zählwerks,SG10,CAV,7110,00350,,,Angabe der Nachkommastelle,X, + 712,Bezeichnung des Zählwerks auf dem Gerät,SG10,,,,,,,Muss [123] ∧[273],"[123] Wenn noch mindestens eine weitere SG8 SEQ+Z20 (OBIS-Daten der Zähleinrichtung Smartmeter- Gateway) mit dem SG8 RFF+MG (Gerätenummer des Zählers) auf die gleiche Identifikation/Nummer des Gerätes referenziert + [273] Wenn in derselben SG8 SEQ+Z20 (OBIS-Daten der Zähleinrichtung / Smartmeter-Gateway) das PIA+5+1-b?:1.8.e / 1-b?:2.8.e / 1-b?:3.8.e / 1-b?:4.8.e / 1-b?: 5.8.e / 1-b?:6.8.e / 1-b?:7.8.e / 1-b?:8.8.e /  1-b?:1.8.63 vorhanden" + 713,Bezeichnung des Zählwerks auf dem Gerät,SG10,CCI,,00351,,,,Muss, + 714,Bezeichnung des Zählwerks auf dem Gerät,SG10,CCI,7037,00351,Z63,,Lokale Kennzeichnung zuKontrollzwecken,X, + 715,Bezeichnung des Zählwerks auf dem Gerät,SG10,CCI,7036,00351,,,Bezeichnung des Zählwerks aufdem Gerät,X, + 716,Wandlerdaten,SG8,,,,,,,Soll [130],[130] Wenn an Messlokation vorhanden + 717,Wandlerdaten,SG8,SEQ,,00353,,,,Muss, + 718,Wandlerdaten,SG8,SEQ,1229,00353,Z04,,Wandler-Daten,X, + 719,Referenz auf die Gerätenummer,SG8,RFF,,00354,,,,Muss, + 720,Referenz auf die Gerätenummer,SG8,RFF,1153,00354,MG,,Gerätenummer des,X, + 721,Referenz auf die Gerätenummer,SG8,RFF,1154,00354,,,Gerätenummer,X, + 722,Wandler,SG10,,,,,,,Muss, + 723,Wandler,SG10,CCI,,00355,,,,Muss, + 724,Wandler,SG10,CCI,7037,00355,Z25,,Wandler,X, + 725,Identifikation / Nummer des Gerätes,SG10,CAV,,00356,,,,Muss [2317] ⊻[2318],"[2317] Wenn in derselben SG8 SEQ+Z04 (Wandlerdaten) das SG10 CCI+++Z25 (Wandler) CAV+MIW/MPW/MUW vorhanden, ist das Segment mindestens zweimal anzugeben + [2318] Wenn in derselben SG8 SEQ+Z04 (Wandlerdaten) das SG10 CCI+++Z25 (Wandler) CAV+MBW (Blockstromwandler) vorhanden, ist das Segment genau einmal anzugeben" + 726,Identifikation / Nummer des Gerätes,SG10,CAV,7111,00356,Z30,,Gerätenummer,X, + 727,Identifikation / Nummer des Gerätes,SG10,CAV,7110,00356,,,Gerätenummer,X, + 728,Wandlertyp und Faktor,SG10,CAV,,00357,,,,Muss, + 729,Wandlertyp und Faktor,SG10,CAV,7111,00357,MIW,,Messwandlersatz Strom,X, + 730,Wandlertyp und Faktor,SG10,CAV,7111,,MPW,,Kombimesswandlersatz(Strom und Spannung),X, + 731,Wandlertyp und Faktor,SG10,CAV,7111,,MBW,,Blockstromwandler,X, + 732,Wandlertyp und Faktor,SG10,CAV,7111,,MUW,,MesswandlersatzSpannung,X, + 733,Wandlertyp und Faktor,SG10,CAV,7110,00357,,,Wandlerfaktor,X [902] [141],"[141] Wenn SG10 CAV+MIW/ MPW/ MBW vorhanden + [902] Format: Möglicher Wert: ≥ 0" + 734,Kommunikationseinrichtun gsdaten,SG8,,,,,,,Muss [2119] Soll [130] ,"[130] Wenn an Messlokation vorhanden + [2119] Je SG8 SEQ+Z13 (Smartmeter-Gateway) ist genau einmal die Segmentgruppe anzugeben" + 735,Kommunikationseinrichtun gsdaten,SG8,SEQ,,00358,,,,Muss, + 736,Kommunikationseinrichtun gsdaten,SG8,SEQ,1229,00358,Z05,,Kommunikationseinrichtungsdaten,X, + 737,Referenz auf die Gerätenummer,SG8,RFF,,00359,,,,Muss, + 738,Referenz auf die Gerätenummer,SG8,RFF,1153,00359,MG,,Gerätenummer desZählers,X, + 739,Referenz auf die Gerätenummer,SG8,RFF,1154,00359,,,Gerätenummer,X, + 740,Kommunikationseinrichtun g,SG10,,,,,,,Muss, + 741,Kommunikationseinrichtun g,SG10,CCI,,00360,,,,Muss, + 742,Kommunikationseinrichtun g,SG10,CCI,7037,00360,Z26,,Kommunikationseinrichtung,X, + 743,Identifikation / Nummer des Gerätes,SG10,CAV,,00361,,,,Muss, + 744,Identifikation / Nummer des Gerätes,SG10,CAV,7111,00361,Z30,,Gerätenummer,X, + 745,Identifikation / Nummer des Gerätes,SG10,CAV,7110,00361,,,Gerätenummer,X, + 746,Kommunikationseinrichtun gstyp,SG10,CAV,,00362,,,,Muss, + 747,Kommunikationseinrichtun gstyp,SG10,CAV,7111,00362,GSM,,GSM/GPRS/UMTS-Kom.-Einr.,X, + 748,Kommunikationseinrichtun gstyp,SG10,CAV,7111,,ETH,,Ethernet-Kom.-Einricht.LAN/WLAN,X, + 749,Kommunikationseinrichtun gstyp,SG10,CAV,7111,,PLC,,PLC-Kom.-Einrichtung,X, + 750,Kommunikationseinrichtun gstyp,SG10,CAV,7111,,PST,,Festnetz-Kom.-Einricht.TAE,X, + 751,Kommunikationseinrichtun gstyp,SG10,CAV,7111,,DSL,,DSL-Kom.Einr.,X, + 752,Kommunikationseinrichtun gstyp,SG10,CAV,7111,,LTE,,LTE-Kom.-Einr.,X, + 753,Daten der technischen Steuereinrichtung,SG8,,,,,,,Soll [130],[130] Wenn an Messlokation vorhanden + 754,Daten der technischen Steuereinrichtung,SG8,SEQ,,00363,,,,Muss, + 755,Daten der technischen Steuereinrichtung,SG8,SEQ,1229,00363,Z06,,Daten der technischenSteuereinrichtung,X, + 756,Referenz auf die Gerätenummer,SG8,RFF,,00364,,,,Muss, + 757,Referenz auf die Gerätenummer,SG8,RFF,1153,00364,MG,,Gerätenummer desZählers,X, + 758,Referenz auf die Gerätenummer,SG8,RFF,1154,00364,,,Gerätenummer,X, + 759,Technische Steuereinrichtung,SG10,,,,,,,Muss, + 760,Technische Steuereinrichtung,SG10,CCI,,00365,,,,Muss, + 761,Technische Steuereinrichtung,SG10,CCI,7037,00365,Z27,,TechnischeSteuereinrichtung,X, + 762,Identifikation / Nummer des Gerätes,SG10,CAV,,00366,,,,Muss, + 763,Identifikation / Nummer des Gerätes,SG10,CAV,7111,00366,Z30,,Gerätenummer,X, + 764,Identifikation / Nummer des Gerätes,SG10,CAV,7110,00366,,,Gerätenummer,X, + 765,Technische Steuereinrichtungstyp,SG10,CAV,,00367,,,,Muss, + 766,Technische Steuereinrichtungstyp,SG10,CAV,7111,00367,RSU,,Rundsteuerempfänger,X, + 767,Technische Steuereinrichtungstyp,SG10,CAV,7111,,TSU,,Tarifschaltuhr,X, + 768,Smartmeter-Gateway,SG8,,,,,,,Soll [130],[130] Wenn an Messlokation vorhanden + 769,Smartmeter-Gateway,SG8,SEQ,,00368,,,,Muss, + 770,Smartmeter-Gateway,SG8,SEQ,1229,00368,Z13,,Smartmeter-Gateway,X, + 771,Smartmeter-Gateway,SG10,,,,,,,Muss, + 772,Smartmeter-Gateway,SG10,CCI,,00369,,,,Muss, + 773,Smartmeter-Gateway,SG10,CCI,7037,00369,Z75,,Smartmeter-Gateway,X, + 774,Identifikation / Nummer des Gerätes,SG10,CAV,,00370,,,,Muss, + 775,Identifikation / Nummer des Gerätes,SG10,CAV,7111,00370,Z30,,Gerätenummer,X, + 776,Identifikation / Nummer des Gerätes,SG10,CAV,7110,00370,,,Gerätenummer,X [952],[952] Format: Gerätenummer nach DIN 43863-5 + 777,Daten der Steuerbox,SG8,,,,,,,Soll [133],[133] Wenn an der übermittelten Marktlokation / Messlokation vorhanden + 778,Daten der Steuerbox,SG8,SEQ,,00371,,,,Muss, + 779,Daten der Steuerbox,SG8,SEQ,1229,00371,Z14,,Steuerbox,X, + 780,Referenz auf das Smartmeter-Gateway,SG8,RFF,,00372,,,,Muss, + 781,Referenz auf das Smartmeter-Gateway,SG8,RFF,1153,00372,Z14,,Smartmeter-Gateway,X, + 782,Referenz auf das Smartmeter-Gateway,SG8,RFF,1154,00372,,,Identifikation / Nummer desSmartmeter-Gateways,X, + 783,Referenz auf die ID der Marktlokation,SG8,RFF,,00373,,,,Muss, + 784,Referenz auf die ID der Marktlokation,SG8,RFF,1153,00373,Z18,,Marktlokation,X, + 785,Referenz auf die ID der Marktlokation,SG8,RFF,1154,00373,,,ID einer Marktlokation,X [950],[950] Format: Marktlokations-ID + 786,Steuerbox,SG10,,,,,,,Muss, + 787,Steuerbox,SG10,CCI,,00374,,,,Muss, + 788,Steuerbox,SG10,CCI,7037,00374,Z76,,Steuerbox,X, + 789,Identifikation / Nummer des Gerätes,SG10,CAV,,00375,,,,Muss, + 790,Identifikation / Nummer des Gerätes,SG10,CAV,7111,00375,Z30,,Gerätenummer,X, + 791,Identifikation / Nummer des Gerätes,SG10,CAV,7110,00375,,,Gerätenummer,X [952],[952] Format: Gerätenummer nach DIN 43863-5 + 792,Profildaten,SG8,,,,,,,Muss [119],"[119] Wenn in der SG8 SEQ+Z01 SG10 CCI+++ZA6 (Prognosegrundlage der Marktlokation: Prognose auf Basis von Profilen) CAV+E02 (SLP/SEP) vorhanden + [607] Hinweis: In diesem Segment bzw. SG sind die zwischen LF und NB im Rahmen der Marktkommunikation ausgetauschten Daten aus der Sicht des NB anzugeben" + 793,Profildaten,SG8,SEQ,,00376,,,,Muss, + 794,Profildaten,SG8,SEQ,1229,00376,Z21,,Profildaten,X, + 795,Referenz auf die ID der Marktlokation,SG8,RFF,,00378,,,,Muss, + 796,Referenz auf die ID der Marktlokation,SG8,RFF,1153,00378,Z18,,Marktlokation,X, + 797,Referenz auf die ID der Marktlokation,SG8,RFF,1154,00378,,,ID einer Marktlokation,X [950],[950] Format: Marktlokations-ID + 798,Normiertes Profil,SG10,,,,,,,Muss, + 799,Normiertes Profil,SG10,CCI,,00380,,,,Muss, + 800,Normiertes Profil,SG10,CCI,7059,00380,Z02,,Standardlastprofil,X,[20] Wenn SG8 SEQ+Z01 (Daten der Marktlokation) SG10 CCI+Z30++Z07 (Verbrauch) vorhanden + 801,Normiertes Profil,SG10,CCI,7037,00380,E01,,synthetisches Verfahren,X, + 802,Normiertes Profil,SG10,CCI,7037,,Z10,,analytisches Verfahren,X [332],[332] Wenn im SG8 SEQ+Z01 (Daten der Marktlokation) das SG10 CCI+6++ZA9 (Aggreg. verantw. ÜNB) nicht vorhanden + 803,Normiertes Profil,SG10,CAV,,00381,,,,Muss, + 804,Normiertes Profil,SG10,CAV,7111,00381,,,Code des Normierten Profils,X, + 805,Profilschardaten,SG8,,,,,,,Muss [89],[89] Wenn im SG8 SEQ+Z01 (Daten der Marktlokation) das SG10 CCI+++ZA6 (Prognosegrundlage der Marktlokation: Prognose auf Basis von Profilen) CAV+E14 (TLP/TEP) vorhanden + 806,Profilschardaten,SG8,SEQ,,00387,,,,Muss, + 807,Profilschardaten,SG8,SEQ,1229,00387,Z08,,Profilschardaten,X, + 808,Referenz auf die ID der Marktlokation,SG8,RFF,,00389,,,,Muss, + 809,Referenz auf die ID der Marktlokation,SG8,RFF,1153,00389,Z18,,Marktlokation,X, + 810,Referenz auf die ID der Marktlokation,SG8,RFF,1154,00389,,,ID einer Marktlokation,X [950],[950] Format: Marktlokations-ID + 811,Profilschar,SG10,,,,,,,Muss, + 812,Profilschar,SG10,CCI,,00397,,,,Muss, + 813,Profilschar,SG10,CCI,7037,00397,Z12,,Profilschar,X, + 814,Profilschar,SG10,CAV,,00398,,,,Muss, + 815,Profilschar,SG10,CAV,7111,00398,,,Code der Profilschar,X, + 816,Normiertes Profil,SG10,,,,,,,Muss, + 817,Normiertes Profil,SG10,CCI,,00399,,,,Muss, + 818,Normiertes Profil,SG10,CCI,7059,00399,Z03,,tagesparameterabhängiges Lastprofil,X, + 819,Normiertes Profil,SG10,CCI,7037,00399,E01,,synthetisches Verfahren,X, + 820,Normiertes Profil,SG10,CCI,7037,,Z10,,analytisches Verfahren,X, + 821,Normiertes Profil,SG10,CAV,,00400,,,,Muss, + 822,Normiertes Profil,SG10,CAV,7111,00400,,,Code des Normierten Profils,X, + 823,Klimazone / Temperaturmessstelle,SG10,,,,,,,Muss, + 824,Klimazone / Temperaturmessstelle,SG10,CCI,,00403,,,,Muss, + 825,Klimazone / Temperaturmessstelle,SG10,CCI,7059,00403,Z99,,Messstelle desTagesparameters(derzeit ist nur dieTemperatur ein erlaubterTagesparameter),X, + 826,Klimazone / Temperaturmessstelle,SG10,CCI,7059,,ZA0,,Klimazone des,X, + 827,Klimazone / Temperaturmessstelle,SG10,CCI,7037,00403,,,ID Klimazone /Temperaturmessstelle,X, + 828,Klimazone / Temperaturmessstelle,SG10,CCI,1131,00403,,,Dienstanbieter,X [58],[58] Wenn in diesem CCI das DE3055 mit dem Code 293 vorhanden + 829,Klimazone / Temperaturmessstelle,SG10,CCI,3055,00403,89,,Vergeben vom Händler(hier Netzbetreiber),X, + 830,Klimazone / Temperaturmessstelle,SG10,CCI,3055,,293,,"DE, BDEW(Bundesverband derEnergie- undWasserwirtschaft e.V.)",X, + 831,Kunde des Lieferanten,SG12,,,,,,,Soll [283],[283] Wenn Empfänger der Nachricht der zum Nachrichtendatum aktuell zugeordnete Lieferant ist + 832,Kunde des Lieferanten,SG12,NAD,,00518,,,,Muss, + 833,Kunde des Lieferanten,SG12,NAD,3035,00518,Z09,,Kunde des LF,X, + 834,Kunde des Lieferanten,SG12,NAD,3036,00518,,,Name,X, + 835,Kunde des Lieferanten,SG12,NAD,3045,00518,Z01,,Struktur vonPersonennamen,X, + 836,Kunde des Lieferanten,SG12,NAD,3045,,Z02,,Struktur derFirmenbezeichnung,X, + 837,Kundennummer beim Lieferanten,SG12,RFF,,00519,,,,Kann, + 838,Kundennummer beim Lieferanten,SG12,RFF,1153,00519,AVC,,Kundennummer beimLieferanten,X, + 839,Kundennummer beim Lieferanten,SG12,RFF,1154,00519,,,Kundennummer beim LF,X, + 840,Referenz auf die ID der Marktlokation,SG12,RFF,,00521,,,,Muss, + 841,Referenz auf die ID der Marktlokation,SG12,RFF,1153,00521,Z18,,Marktlokation,X, + 842,Referenz auf die ID der Marktlokation,SG12,RFF,1154,00521,,,ID der Marktlokation,X [950],[950] Format: Marktlokations-ID + 843,Marktlokationsanschrift,SG12,,,,,,,Muss, + 844,Marktlokationsanschrift,SG12,NAD,,00535,,,,Muss, + 845,Marktlokationsanschrift,SG12,NAD,3035,00535,DP,,Lieferanschrift,X, + 846,Marktlokationsanschrift,SG12,NAD,3124,00535,,,Zusatzinformation zurIdentifizierung,K, + 847,Marktlokationsanschrift,SG12,NAD,3042,00535,,,Straße und Hausnummer oderPostfach,S [166]M [212],"[166] Wenn vorhanden + [212] Wenn im selben SG12 NAD DE3124 nicht vorhanden" + 848,Marktlokationsanschrift,SG12,NAD,3164,00535,,,Ort,X, + 849,Marktlokationsanschrift,SG12,NAD,3251,00535,,,Postleitzahl,X, + 850,Marktlokationsanschrift,SG12,NAD,3207,00535,,,"Ländername, Code",X, + 851,Nachrichten-Endesegment,,UNT,,00540,,,,Muss, + 852,Nachrichten-Endesegment,,UNT,0074,00540,,,Anzahl der Segmente in einerNachricht,X, + 853,Nachrichten-Endesegment,,UNT,0062,00540,,,Nachrichten-Referenznummer,X, + + ''' +# --- +# name: TestCli.test_kohlrahbi_cli_with_valid_arguments[55041] + ''' + ,Segmentname,Segmentgruppe,Segment,Datenelement,Segment ID,Code,Qualifier,Beschreibung,Bedingungsausdruck,Bedingung + 0,Nachrichten-Kopfsegment,,UNH,,00003,,,,Muss, + 1,Nachrichten-Kopfsegment,,UNH,0062,00003,,,Nachrichten-Referenznummer,X, + 2,Nachrichten-Kopfsegment,,UNH,0065,00003,UTILMD,,Netzanschluss-Stammdaten,X, + 3,Nachrichten-Kopfsegment,,UNH,0052,00003,D,,Entwurfs-Version,X, + 4,Nachrichten-Kopfsegment,,UNH,0054,00003,11A,,Ausgabe 2011 - A,X, + 5,Nachrichten-Kopfsegment,,UNH,0051,00003,UN,,UN/CEFACT,X, + 6,Nachrichten-Kopfsegment,,UNH,0057,00003,Versionsnummer derzugrundeliegendenBDEW-Nachrichtenbeschreibung,,S1.1a,X, + 7,Beginn der Nachricht,,BGM,,00004,,,,Muss, + 8,Beginn der Nachricht,,BGM,1001,00004,E35,,Kündigung,X, + 9,Beginn der Nachricht,,BGM,1004,00004,,,Dokumentennummer,X, + 10,Nachrichtendatum,,DTM,,00005,,,,Muss, + 11,Nachrichtendatum,,DTM,2005,00005,137,,Dokumenten-/Nachrichtendatum/-zeit,X, + 12,Nachrichtendatum,,DTM,2380,00005,,,"Datum oder Uhrzeit oderZeitspanne, Wert",X [931][494],"[494] Das hier genannte Datum muss der Zeitpunkt sein, zu dem das Dokument erstellt wurde, oder ein Zeitpunkt, der davor liegt + [931] Format: ZZZ = +00" + 13,Nachrichtendatum,,DTM,2379,00005,303,,CCYYMMDDHHMMZZZ,X, + 14,MP-ID Absender,SG2,,,,,,,Muss, + 15,MP-ID Absender,SG2,NAD,,00008,,,,Muss, + 16,MP-ID Absender,SG2,NAD,3035,00008,MS,,Dokumenten-/Nachrichtenausstellerbzw. -absender,X, + 17,MP-ID Absender,SG2,NAD,3039,00008,,,MP-ID,X, + 18,MP-ID Absender,SG2,NAD,3055,00008,9,,GS1,X, + 19,MP-ID Absender,SG2,NAD,3055,,293,,"DE, BDEW(Bundesverband derEnergie- undWasserwirtschaft e.V.)",X, + 20,Ansprechpartner,SG3,,,,,,,Kann, + 21,Ansprechpartner,SG3,CTA,,00009,,,,Muss, + 22,Ansprechpartner,SG3,CTA,3139,00009,IC,,Informationskontakt,X, + 23,Ansprechpartner,SG3,CTA,3412,00009,,,Name vom Ansprechpartner,X, + 24,Kommunikationsverbindung,SG3,COM,,00010,,,,Muss, + 25,Kommunikationsverbindung,SG3,COM,3148,00010,,,Nummer / Adresse,X (([939][321]) ∨([940][322])) ∧[514],"[321] Wenn im DE3155 in demselben COM der Code EM vorhanden ist + [322] Wenn im DE3155 in demselben COM der Code TE / FX / AJ / AL vorhanden ist + [514] Hinweis: Es darf nur eine Information im DE3148 übermittelt werden + [939] Format: Die Zeichenkette muss die Zeichen @ und . enthalten + [940] Format: Die Zeichenkette muss mit dem Zeichen + beginnen und danach dürfen nur noch Ziffern folgen" + 26,Kommunikationsverbindung,SG3,COM,3155,00010,EM,,Elektronische Post,X [1P0..1], + 27,Kommunikationsverbindung,SG3,COM,3155,,FX,,Telefax,X [1P0..1], + 28,Kommunikationsverbindung,SG3,COM,3155,,TE,,Telefon,X [1P0..1], + 29,Kommunikationsverbindung,SG3,COM,3155,,AJ,,weiteres Telefon,X [1P0..1], + 30,Kommunikationsverbindung,SG3,COM,3155,,AL,,Handy,X [1P0..1], + 31,MP-ID Empfänger,SG2,,,,,,,Muss, + 32,MP-ID Empfänger,SG2,NAD,,00011,,,,Muss, + 33,MP-ID Empfänger,SG2,NAD,3035,00011,MR,,Nachrichtenempfänger,X, + 34,MP-ID Empfänger,SG2,NAD,3039,00011,,,MP-ID,X, + 35,MP-ID Empfänger,SG2,NAD,3055,00011,9,,GS1,X, + 36,MP-ID Empfänger,SG2,NAD,3055,,293,,"DE, BDEW(Bundesverband derEnergie- undWasserwirtschaft e.V.)",X, + 37,Vorgang,SG4,,,,,,,Muss, + 38,Vorgang,SG4,IDE,,00020,,,,Muss, + 39,Vorgang,SG4,IDE,7495,00020,24,,Transaktion,X, + 40,Vorgang,SG4,IDE,7402,00020,,,Vorgangsnummer,X, + 41,Ende zum,SG4,DTM,,00025,,,,,[12] Wenn SG4 DTM+471 (Ende zum nächstmöglichem Termin) nicht vorhanden + 42,Ende zum,SG4,DTM,2005,00025,93,,Datum Vertragsende,, + 43,Ende zum,SG4,DTM,2380,00025,,,"Datum oder Uhrzeit oderZeitspanne, Wert",, + 44,Ende zum,SG4,DTM,2379,00025,303,,CCYYMMDDHHMMZZZ,, + 45,"Änderung zum, Gültigkeit, Beginndatum",SG4,DTM,,00027,,,,Muss [16] ∧[581],"[16] Wenn SG4 STS+E01++Z12 (Status der Antwort: Ablehnung Vertragsbindung) vorhanden + [581] Hinweis: Es ist das nächst mögliche Kündigungsdatum anzugeben" + 46,"Änderung zum, Gültigkeit, Beginndatum",SG4,DTM,2005,00027,157,,"Gültigkeit, Beginndatum",X, + 47,"Änderung zum, Gültigkeit, Beginndatum",SG4,DTM,2380,00027,,,"Datum oder Uhrzeit oderZeitspanne, Wert",X [UB1], + 48,"Änderung zum, Gültigkeit, Beginndatum",SG4,DTM,2379,00027,303,,CCYYMMDDHHMMZZZ,X, + 49,Ende zum (nächstmöglichem Termin),SG4,DTM,,00028,,,,,[18] Wenn SG4 DTM+93 (Ende zum) nicht vorhanden + 50,Ende zum (nächstmöglichem Termin),SG4,DTM,2005,00028,471,,Ende zum(nächstmöglichemTermin),, + 51,Ende zum (nächstmöglichem Termin),SG4,DTM,2380,00028,,,"Datum oder Uhrzeit oderZeitspanne, Wert",, + 52,Ende zum (nächstmöglichem Termin),SG4,DTM,2379,00028,303,,CCYYMMDDHHMMZZZ,, + 53,Kündigungsfrist des Vertrags,SG4,DTM,,00031,,,,Muss, + 54,Kündigungsfrist des Vertrags,SG4,DTM,2005,00031,Z01,,Kündigungsfrist,X, + 55,Kündigungsfrist des Vertrags,SG4,DTM,2380,00031,,,"Datum oder Uhrzeit oderZeitspanne, Wert",X, + 56,Kündigungsfrist des Vertrags,SG4,DTM,2379,00031,Z01,,ZZRB,X, + 57,Kündigungstermin des Vertrags,SG4,DTM,,00032,,,,Muss [35],[35] Wenn das DE2380 von SG4 DTM+Z01 (Kündigungsfrist des Vertrags) an vierter Stelle T (Termin) enthält + 58,Kündigungstermin des Vertrags,SG4,DTM,2005,00032,Z10,,Kündigungstermin,X, + 59,Kündigungstermin des Vertrags,SG4,DTM,2380,00032,,,"Datum oder Uhrzeit oderZeitspanne, Wert",X [UB1] ∧[209],[209] Wenn im selben Segment im DE2379 der Code 303 vorhanden ist + 60,Kündigungstermin des Vertrags,SG4,DTM,2379,00032,106,,MMDD,X, + 61,Kündigungstermin des Vertrags,SG4,DTM,2379,,303,,CCYYMMDDHHMMZZZ,X, + 62,Transaktionsgrund,SG4,STS,,00037,,,,Muss [2061],[2061] Segment bzw. Segmentgruppe ist genau einmal je SG4 IDE (Vorgang) anzugeben + 63,Transaktionsgrund,SG4,STS,9015,00037,7,,Transaktionsgrund,X, + 64,Transaktionsgrund,SG4,STS,9013,00037,E03,,Wechsel,X, + 65,Transaktionsgrund,SG4,STS,9013,,ZR9,,Kündigung aufgrundVertrag mitAnschlussnehmer,X, + 66,Status der Antwort,SG4,STS,,00039,,,,Muss [249],[249] Innerhalb eines SG4 IDE müssen alle DE1131 der SG4 STS+E01 den identischen Wert enthalten + 67,Status der Antwort,SG4,STS,9015,00039,E01,,Status der Antwort,X, + 68,Status der Antwort,SG4,STS,9013,00039,,,Code des Prüfschritts,X, + 69,Status der Antwort,SG4,STS,1131,00039,Codeliste Strom Nr.S_0054Codeliste Strom Nr.S_0090,,S_0054S_0090,X, + 70,Marktlokation,SG5,,,,,,,,"[77] Wenn SG8 SEQ+Z03 (Zähleinrichtungsdaten) CAV+Z30 (Identifikation/Nummer des Gerätes) nicht vorhanden + [349] Wenn SG5 LOC+Z17 (Messlokation) nicht vorhanden" + 71,Marktlokation,SG5,LOC,,00051,,,,, + 72,Marktlokation,SG5,LOC,3227,00051,Z16,,Marktlokation,, + 73,Marktlokation,SG5,LOC,3225,00051,,,ID der Marktlokation,,[950] Format: Marktlokations-ID + 74,Messlokation,SG5,,,,,,,Muss [2061],"[77] Wenn SG8 SEQ+Z03 (Zähleinrichtungsdaten) CAV+Z30 (Identifikation/Nummer des Gerätes) nicht vorhanden + [347] Wenn SG5 LOC+Z16 (Marktlokation) nicht vorhanden + [2061] Segment bzw. Segmentgruppe ist genau einmal je SG4 IDE (Vorgang) anzugeben" + 75,Messlokation,SG5,LOC,,00055,,,,Muss, + 76,Messlokation,SG5,LOC,3227,00055,Z17,,Messlokation,X, + 77,Messlokation,SG5,LOC,3225,00055,,,ID der Messlokation,X [951],[951] Format: Zählpunktbezeichnung + 78,Prüfidentifikator,SG6,,,,,,,Muss, + 79,Prüfidentifikator,SG6,RFF,,00057,,,,Muss, + 80,Prüfidentifikator,SG6,RFF,1153,00057,Z13,,Prüfidentifikator,X, + 81,Prüfidentifikator,SG6,RFF,1154,00057,55039,,WiM Strom / KündigungMSB,, + 82,Prüfidentifikator,SG6,RFF,1154,,55040,,WiM Strom / BestätigungKündigung MSB,, + 83,Prüfidentifikator,SG6,RFF,1154,,55041,,WiM Strom / AblehnungKündigung MSB,X, + 84,Referenz Vorgangsnummer (aus Anfragenachricht),SG6,,,,,,,Muss, + 85,Referenz Vorgangsnummer (aus Anfragenachricht),SG6,RFF,,00058,,,,Muss, + 86,Referenz Vorgangsnummer (aus Anfragenachricht),SG6,RFF,1153,00058,TN,,Transaktions-Referenznummer,X, + 87,Referenz Vorgangsnummer (aus Anfragenachricht),SG6,RFF,1154,00058,,,Vorgangsnummer,X, + 88,Zähleinrichtungsdaten,SG8,,,,,,,,"[347] Wenn SG5 LOC+Z16 (Marktlokation) nicht vorhanden + [349] Wenn SG5 LOC+Z17 (Messlokation) nicht vorhanden" + 89,Zähleinrichtungsdaten,SG8,SEQ,,00326,,,,, + 90,Zähleinrichtungsdaten,SG8,SEQ,1229,00326,Z03,,Zähleinrichtungsdaten,, + 91,Referenz auf die ID einer Messlokation,SG8,RFF,,00327,,,,, + 92,Referenz auf die ID einer Messlokation,SG8,RFF,1153,00327,Z19,,Messlokation,, + 93,Referenz auf die ID einer Messlokation,SG8,RFF,1154,00327,,,ID einer Messlokation,,[951] Format: Zählpunktbezeichnung + 94,Zählertyp,SG10,,,,,,,, + 95,Zählertyp,SG10,CCI,,00329,,,,, + 96,Zählertyp,SG10,CCI,7037,00329,E13,,Zählertyp,, + 97,Identifikation / Nummer des Gerätes,SG10,CAV,,00331,,,,, + 98,Identifikation / Nummer des Gerätes,SG10,CAV,7111,00331,Z30,,Gerätenummer,, + 99,Identifikation / Nummer des Gerätes,SG10,CAV,7110,00331,,,Gerätenummer,, + 100,Kunde des Messstellenbetreibers,SG12,,,,,,,, + 101,Kunde des Messstellenbetreibers,SG12,NAD,,00524,,,,, + 102,Kunde des Messstellenbetreibers,SG12,NAD,3035,00524,Z07,,Kunde des MSB,, + 103,Kunde des Messstellenbetreibers,SG12,NAD,3036,00524,,,Name,, + 104,Kunde des Messstellenbetreibers,SG12,NAD,3045,00524,Z01,,Struktur vonPersonennamen,, + 105,Kunde des Messstellenbetreibers,SG12,NAD,3045,,Z02,,Struktur derFirmenbezeichnung,, + 106,Referenz auf die ID der Messlokation,SG12,RFF,,00525,,,,, + 107,Referenz auf die ID der Messlokation,SG12,RFF,1153,00525,Z19,,Messlokation,, + 108,Referenz auf die ID der Messlokation,SG12,RFF,1154,00525,,,ID der Messlokation,,[951] Format: Zählpunktbezeichnung + 109,Messlokationsadresse,SG12,,,,,,,,[165] Wenn bekannt + 110,Messlokationsadresse,SG12,NAD,,00536,,,,, + 111,Messlokationsadresse,SG12,NAD,3035,00536,Z03,,Messlokationsadresse,, + 112,Messlokationsadresse,SG12,NAD,3124,00536,,,Zusatzinformation zurIdentifizierung,, + 113,Messlokationsadresse,SG12,NAD,3042,00536,,,Straße und Hausnummer oderPostfach,,"[166] Wenn vorhanden + [212] Wenn im selben SG12 NAD DE3124 nicht vorhanden" + 114,Messlokationsadresse,SG12,NAD,3164,00536,,,Ort,, + 115,Messlokationsadresse,SG12,NAD,3251,00536,,,Postleitzahl,, + 116,Messlokationsadresse,SG12,NAD,3207,00536,,,"Ländername, Code",, + 117,Referenz auf die ID einer Messlokation,SG12,RFF,,00537,,,,, + 118,Referenz auf die ID einer Messlokation,SG12,RFF,1153,00537,Z19,,Messlokation,, + 119,Referenz auf die ID einer Messlokation,SG12,RFF,1154,00537,,,ID einer Messlokation,,[951] Format: Zählpunktbezeichnung + 120,Nachrichten-Endesegment,,UNT,,00540,,,,Muss, + 121,Nachrichten-Endesegment,,UNT,0074,00540,,,Anzahl der Segmente in einerNachricht,X, + 122,Nachrichten-Endesegment,,UNT,0062,00540,,,Nachrichten-Referenznummer,X, + + ''' +# --- +# name: TestCli.test_kohlrahbi_cli_with_valid_arguments[55062] + ''' + ,Segmentname,Segmentgruppe,Segment,Datenelement,Segment ID,Code,Qualifier,Beschreibung,Bedingungsausdruck,Bedingung + 0,Nachrichten-Kopfsegment,,UNH,,00003,,,,Muss, + 1,Nachrichten-Kopfsegment,,UNH,0062,00003,,,Nachrichten-Referenznummer,X, + 2,Nachrichten-Kopfsegment,,UNH,0065,00003,UTILMD,,Netzanschluss-Stammdaten,X, + 3,Nachrichten-Kopfsegment,,UNH,0052,00003,D,,Entwurfs-Version,X, + 4,Nachrichten-Kopfsegment,,UNH,0054,00003,11A,,Ausgabe 2011 - A,X, + 5,Nachrichten-Kopfsegment,,UNH,0051,00003,UN,,UN/CEFACT,X, + 6,Nachrichten-Kopfsegment,,UNH,0057,00003,Versionsnummer derzugrundeliegendenBDEW-Nachrichtenbeschreibung,,S1.1a,X, + 7,Beginn der Nachricht,,BGM,,00004,,,,Muss, + 8,Beginn der Nachricht,,BGM,1001,00004,Z07,,Aktivierung/Deaktivierung vonMaBiS-ZP,X, + 9,Beginn der Nachricht,,BGM,1004,00004,,,Dokumentennummer,X, + 10,Nachrichtendatum,,DTM,,00005,,,,Muss, + 11,Nachrichtendatum,,DTM,2005,00005,137,,Dokumenten-/Nachrichtendatum/-zeit,X, + 12,Nachrichtendatum,,DTM,2380,00005,,,"Datum oder Uhrzeit oderZeitspanne, Wert",X [931][494],"[494] Das hier genannte Datum muss der Zeitpunkt sein, zu dem das Dokument erstellt wurde, oder ein Zeitpunkt, der davor liegt + [931] Format: ZZZ = +00" + 13,Nachrichtendatum,,DTM,2379,00005,303,,CCYYMMDDHHMMZZZ,X, + 14,MP-ID Absender,SG2,,,,,,,Muss, + 15,MP-ID Absender,SG2,NAD,,00008,,,,Muss, + 16,MP-ID Absender,SG2,NAD,3035,00008,MS,,Dokumenten-/Nachrichtenausstellerbzw. -absender,X, + 17,MP-ID Absender,SG2,NAD,3039,00008,,,MP-ID,X, + 18,MP-ID Absender,SG2,NAD,3055,00008,9,,GS1,X, + 19,MP-ID Absender,SG2,NAD,3055,,293,,"DE, BDEW(Bundesverband derEnergie- undWasserwirtschaft e.V.)",X, + 20,Ansprechpartner,SG3,,,,,,,Kann, + 21,Ansprechpartner,SG3,CTA,,00009,,,,Muss, + 22,Ansprechpartner,SG3,CTA,3139,00009,IC,,Informationskontakt,X, + 23,Ansprechpartner,SG3,CTA,3412,00009,,,Name vom Ansprechpartner,X, + 24,Kommunikationsverbindung,SG3,COM,,00010,,,,Muss, + 25,Kommunikationsverbindung,SG3,COM,3148,00010,,,Nummer / Adresse,X (([939][321]) ∨([940][322])) ∧[514],"[321] Wenn im DE3155 in demselben COM der Code EM vorhanden ist + [322] Wenn im DE3155 in demselben COM der Code TE / FX / AJ / AL vorhanden ist + [514] Hinweis: Es darf nur eine Information im DE3148 übermittelt werden + [939] Format: Die Zeichenkette muss die Zeichen @ und . enthalten + [940] Format: Die Zeichenkette muss mit dem Zeichen + beginnen und danach dürfen nur noch Ziffern folgen" + 26,Kommunikationsverbindung,SG3,COM,3155,00010,EM,,Elektronische Post,X [1P0..1], + 27,Kommunikationsverbindung,SG3,COM,3155,,FX,,Telefax,X [1P0..1], + 28,Kommunikationsverbindung,SG3,COM,3155,,TE,,Telefon,X [1P0..1], + 29,Kommunikationsverbindung,SG3,COM,3155,,AJ,,weiteres Telefon,X [1P0..1], + 30,Kommunikationsverbindung,SG3,COM,3155,,AL,,Handy,X [1P0..1], + 31,MP-ID Empfänger,SG2,,,,,,,Muss, + 32,MP-ID Empfänger,SG2,NAD,,00011,,,,Muss, + 33,MP-ID Empfänger,SG2,NAD,3035,00011,MR,,Nachrichtenempfänger,X, + 34,MP-ID Empfänger,SG2,NAD,3039,00011,,,MP-ID,X [280],[280] Nur MP-ID aus Sparte Strom + 35,MP-ID Empfänger,SG2,NAD,3055,00011,9,,GS1,X, + 36,MP-ID Empfänger,SG2,NAD,3055,,293,,"DE, BDEW",X, + 37,Vorgang,SG4,,,,,,,Muss, + 38,Vorgang,SG4,IDE,,00020,,,,Muss, + 39,Vorgang,SG4,IDE,7495,00020,24,,Transaktion,X, + 40,Vorgang,SG4,IDE,7402,00020,,,Vorgangsnummer,X, + 41,Bilanzierungsbeginn,SG4,DTM,,00029,,,,Muss,[30] Wenn Antwort auf Aktivierung übermittelt wird + 42,Bilanzierungsbeginn,SG4,DTM,2005,00029,158,,Bilanzierungsbeginn,X, + 43,Bilanzierungsbeginn,SG4,DTM,2380,00029,,,"Datum oder Uhrzeit oderZeitspanne, Wert",X [UB1], + 44,Bilanzierungsbeginn,SG4,DTM,2379,00029,303,,CCYYMMDDHHMMZZZ,X, + 45,Bilanzierungsende,SG4,DTM,,00030,,,,,[34] Wenn Antwort auf Deaktivierung übermittelt wird + 46,Bilanzierungsende,SG4,DTM,2005,00030,159,,Bilanzierungsende,, + 47,Bilanzierungsende,SG4,DTM,2380,00030,,,"Datum oder Uhrzeit oderZeitspanne, Wert",, + 48,Bilanzierungsende,SG4,DTM,2379,00030,303,,CCYYMMDDHHMMZZZ,, + 49,Status der Antwort,SG4,STS,,00039,,,,,[249] Innerhalb eines SG4 IDE müssen alle DE1131 der SG4 STS+E01 den identischen Wert enthalten + 50,Status der Antwort,SG4,STS,9015,00039,E01,,Status der Antwort,, + 51,Status der Antwort,SG4,STS,9013,00039,,,Code des Prüfschritts,, + 52,Status der Antwort,SG4,STS,1131,00039,E_0009,,EBD Nr. E_0009,, + 53,Status der Antwort,SG4,STS,1131,,E_0010,,EBD Nr. E_0010,, + 54,Status der Antwort,SG4,STS,1131,,E_0011,,EBD Nr. E_0011,,"[6] Wenn MP-ID in SG2 NAD+MR (Nachrichtenempfänger) in der Rolle ÜNB + [98] Wenn MP-ID in SG2 NAD+MS" + 55,MaBiS-Zählpunkt,SG5,,,,,,,Muss [2061],[2061] Segment bzw. Segmentgruppe ist genau einmal je SG4 IDE (Vorgang) anzugeben + 56,MaBiS-Zählpunkt,SG5,LOC,,00056,,,,Muss, + 57,MaBiS-Zählpunkt,SG5,LOC,3227,00056,Z15,,MaBiS-Zählpunkt,X, + 58,MaBiS-Zählpunkt,SG5,LOC,3225,00056,,,Identifikator,X [951],[951] Format: Zählpunktbezeichnung + 59,Prüfidentifikator,SG6,,,,,,,Muss, + 60,Prüfidentifikator,SG6,RFF,,00057,,,,Muss, + 61,Prüfidentifikator,SG6,RFF,1153,00057,Z13,,Prüfidentifikator,X, + 62,Prüfidentifikator,SG6,RFF,1154,00057,55062,,MaBiS / Aktivierung vonMaBiS-ZP,X, + 63,Prüfidentifikator,SG6,RFF,1154,,55063,,MaBiS / Deaktivierungvon MaBiS-ZP,, + 64,Prüfidentifikator,SG6,RFF,1154,,55064,,MaBiS / Antwort aufAktivierung /Deaktivierung vonMaBiS-ZP,, + 65,Referenz Vorgangsnummer (aus Anfragenachricht),SG6,,,,,,,, + 66,Referenz Vorgangsnummer (aus Anfragenachricht),SG6,RFF,,00058,,,,, + 67,Referenz Vorgangsnummer (aus Anfragenachricht),SG6,RFF,1153,00058,TN,,Transaktions-,, + 68,Referenz Vorgangsnummer (aus Anfragenachricht),SG6,RFF,1154,00058,,,Vorgangsnummer,, + 69,Daten der Summenzeitreihe,SG8,,,,,,,Muss [2061],[2061] Segment bzw. Segmentgruppe ist genau einmal je SG4 IDE (Vorgang) anzugeben + 70,Daten der Summenzeitreihe,SG8,SEQ,,00422,,,,Muss, + 71,Daten der Summenzeitreihe,SG8,SEQ,1229,00422,Z22,,Daten derSummenzeitreihe,X, + 72,Bezeichnung der Summenzeitreihe,SG10,,,,,,,Muss, + 73,Bezeichnung der Summenzeitreihe,SG10,CCI,,00425,,,,Muss, + 74,Bezeichnung der Summenzeitreihe,SG10,CCI,7037,00425,ZB4,,Bezeichnung derSummenzeitreihe,X, + 75,Bezeichnung der Summenzeitreihe,SG10,CAV,,00426,,,,Muss, + 76,Bezeichnung der Summenzeitreihe,SG10,CAV,7111,00426,Z95,,BG-SZR (Kategorie B),X, + 77,Bezeichnung der Summenzeitreihe,SG10,CAV,7111,,Z96,,BG-SZR (Kategorie C),X, + 78,Bezeichnung der Summenzeitreihe,SG10,CAV,7111,,Z97,,BK-SZR (Kategorie A),X, + 79,Bezeichnung der Summenzeitreihe,SG10,CAV,7111,,Z98,,BK-SZR (Kategorie B) aufEbene Regelzone,X, + 80,Bezeichnung der Summenzeitreihe,SG10,CAV,7111,,Z99,,BK-SZR (Kategorie B) aufEbeneBilanzierungsgebiet,X, + 81,Bezeichnung der Summenzeitreihe,SG10,CAV,7111,,ZA0,,BK-SZR (Kategorie C),X, + 82,Bezeichnung der Summenzeitreihe,SG10,CAV,7111,,ZA1,,LF-SZR (Kategorie A),X, + 83,Bezeichnung der Summenzeitreihe,SG10,CAV,7111,,ZA2,,LF-SZR (Kategorie B) aufEbene Regelzone,X, + 84,Bezeichnung der Summenzeitreihe,SG10,CAV,7111,,ZA3,,LF-SZR (Kategorie B) aufEbeneBilanzierungsgebiet,X, + 85,Bezeichnung der Summenzeitreihe,SG10,CAV,7111,,ZA4,,Deltazeitreihenübertrag(DZÜ),X, + 86,Bezeichnung der Summenzeitreihe,SG10,CAV,7111,,ZA5,,Netzzeitreihe (NZR),X, + 87,Bezeichnung der Summenzeitreihe,SG10,CAV,7111,,ZA6,,Abrechnungssummenzeitreihe,X, + 88,Bezeichnung der Summenzeitreihe,SG10,CAV,7111,,ZG7,,"BK-SZR (eMob, täglich)",X, + 89,Verantwortliche Marktrolle für Summenzeitreihe,SG10,,,,,,,Muss, + 90,Verantwortliche Marktrolle für Summenzeitreihe,SG10,CCI,,00427,,,,Muss, + 91,Verantwortliche Marktrolle für Summenzeitreihe,SG10,CCI,7059,00427,6,,Verantwortlicher,X, + 92,Verantwortliche Marktrolle für Summenzeitreihe,SG10,CCI,7037,00427,ZA8,,NB,X, + 93,Verantwortliche Marktrolle für Summenzeitreihe,SG10,CCI,7037,,ZA9,,ÜNB,X, + 94,Verantwortliche Marktrolle für Summenzeitreihe,SG10,CCI,7037,,ZB7,,BIKO,X, + 95,Regelzone,SG10,,,,,,,Muss, + 96,Regelzone,SG10,CCI,,00428,,,,Muss, + 97,Regelzone,SG10,CCI,7059,00428,Z18,,Regelzone,X, + 98,Regelzone,SG10,CCI,7037,00428,,,Regelzone,X, + 99,Bilanzierungsgebiet,SG10,,,,,,,Muss [2060]⊻ [338]Soll [166],"[166] Wenn vorhanden + [338] Wenn CCI+++ZB4 (Bezeichnung der Summenzeitreihe) CAV+Z95/ Z96/ Z97/ Z99/ ZA1/ ZA3/ ZA4/ZG7 vorhanden + [2060] Wenn SG10 CAV+NZR ist die Segmentgruppe genau zwei Mal je IDE+24 anzugeben" + 100,Bilanzierungsgebiet,SG10,CCI,,00429,,,,Muss, + 101,Bilanzierungsgebiet,SG10,CCI,7059,00429,Z20,,Bilanzierungsgebiet,X, + 102,Bilanzierungsgebiet,SG10,CCI,7037,00429,,,Bilanzierungsgebiet,X, + 103,Bilanzkreis,SG10,,,,,,,Muss [339],[339] Wenn CCI+++ZB4 (Bezeichnung der Summenzeitreihe) CAV+Z97/ Z98/ Z99/ ZA0/ ZA1/ ZA2/ ZA3/ ZA6/ ZG7 vorhanden + 104,Bilanzkreis,SG10,CCI,,00430,,,,Muss, + 105,Bilanzkreis,SG10,CCI,7059,00430,Z19,,Bilanzkreis,X, + 106,Bilanzkreis,SG10,CCI,7037,00430,,,Bilanzkreis,X, + 107,Zeitreihentyp,SG10,,,,,,,Muss, + 108,Zeitreihentyp,SG10,CCI,,00431,,,,Muss, + 109,Zeitreihentyp,SG10,CCI,7059,00431,15,,Struktur,X, + 110,Zeitreihentyp,SG10,CCI,7037,00431,Z21,,Summenzeitreihentyp,X, + 111,Zeitreihentyp,SG10,CAV,,00432,,,,Muss, + 112,Zeitreihentyp,SG10,CAV,7111,00432,,,Code des Zeitreihentyps,X, + 113,Bezugszeitraum der Summenzeitreihe,SG10,,,,,,,Muss, + 114,Bezugszeitraum der Summenzeitreihe,SG10,CCI,,00433,,,,Muss, + 115,Bezugszeitraum der Summenzeitreihe,SG10,CCI,7037,00433,ZB6,,Bezugszeitraum derSummenzeitreihe,X, + 116,Bezugszeitraum der Summenzeitreihe,SG10,CAV,,00434,,,,Muss, + 117,Bezugszeitraum der Summenzeitreihe,SG10,CAV,7111,00434,Z94,,Monat,X [340], + 118,Bezugszeitraum der Summenzeitreihe,SG10,CAV,7111,,Z93,,Tag,X [341],"[340] Wenn CCI+++ZB4 (Bezeichnung der Summenzeitreihe) CAV+Z95/ Z97/ Z98/ Z99/ ZA1/ ZA2/ ZA3/ ZA4/ ZA5/ ZA6 vorhanden + [341] Wenn CCI+++ZB4 (Bezeichnung der Summenzeitreihe) CAV+Z96/ ZA0/ ZG7 vorhanden" + 119,Spannungsebene der Summenzeitreihe,SG10,,,,,,,Muss [337],[337] Wenn SG10 CCI+++ZB4 (Bezeichnung der Summenzeitreihe) CAV+Z95/ Z96 vorhanden + 120,Spannungsebene der Summenzeitreihe,SG10,CCI,,00435,,,,Muss, + 121,Spannungsebene der Summenzeitreihe,SG10,CCI,7037,00435,ZB5,,Spannungsebene derSummenzeitreihe,X, + 122,Spannungsebene der Summenzeitreihe,SG10,CAV,,00436,,,,Muss, + 123,Spannungsebene der Summenzeitreihe,SG10,CAV,7111,00436,E03,,Höchstspannung,X, + 124,Spannungsebene der Summenzeitreihe,SG10,CAV,7111,,E04,,Hochspannung,X, + 125,Spannungsebene der Summenzeitreihe,SG10,CAV,7111,,E05,,Mittelspannung,X, + 126,Umspannung,SG10,CAV,,00437,,,,Soll [166],[166] Wenn vorhanden + 127,Umspannung,SG10,CAV,7111,00437,E07,,Hös/HS Umspannung,X [195], + 128,Umspannung,SG10,CAV,7111,,E08,,HS/MS Umspannung,X [194], + 129,Umspannung,SG10,CAV,7111,,E09,,MS/NS Umspannung,X [193],"[193] Wenn das SG10 CCI ZB5 (Spannungsebene der Summenzeitreihe) CAV E06 (Niederspannung) in dieser SG vorhanden + [194] Wenn das SG10 CCI ZB5 (Spannungsebene der Summenzeitreihe) CAV E05 (Mittelspannung) in dieser SG vorhanden + [195] Wenn das SG10 CCI ZB5 (Spannungsebene der Summenzeitreihe) CAV E04 (Hochspannung) in dieser SG vorhanden" + 130,Produkt-Daten der Summenzeitreihe,SG8,,,,,,,Muss [2080],[2080] Segmentgruppe ist max. zweimal je SG4 IDE+24 (Vorgang) anzugeben + 131,Produkt-Daten der Summenzeitreihe,SG8,SEQ,,00440,,,,Muss, + 132,Produkt-Daten der Summenzeitreihe,SG8,SEQ,1229,00440,Z23,,Produkt-Daten derSummenzeitreihe,X, + 133,Produktidentifikation der Summenzeitreihe,SG8,PIA,,00441,,,,Muss, + 134,Produktidentifikation der Summenzeitreihe,SG8,PIA,4347,00441,5,,Produktidentifikation,X, + 135,Produktidentifikation der Summenzeitreihe,SG8,PIA,7140,00441,,,Produktidentifikation derSummenzeitreihe,X, + 136,Produktidentifikation der Summenzeitreihe,SG8,PIA,7143,00441,SRW,,OBIS-Kennzahl,X, + 137,Nachrichten-Endesegment,,UNT,,00540,,,,Muss, + 138,Nachrichten-Endesegment,,UNT,0074,00540,,,Anzahl der Segmente in einer,X, + 139,Nachrichten-Endesegment,,UNT,0062,00540,,,Nachrichten-Referenznummer,X, + + ''' +# --- +# name: TestCli.test_kohlrahbi_cli_with_valid_arguments[55074] + ''' + ,Segmentname,Segmentgruppe,Segment,Datenelement,Segment ID,Code,Qualifier,Beschreibung,Bedingungsausdruck,Bedingung + 0,Nachrichten-Kopfsegment,,UNH,,00003,,,,Muss, + 1,Nachrichten-Kopfsegment,,UNH,0062,00003,,,Nachrichten-Referenznummer,X, + 2,Nachrichten-Kopfsegment,,UNH,0065,00003,UTILMD,,Netzanschluss-Stammdaten,X, + 3,Nachrichten-Kopfsegment,,UNH,0052,00003,D,,Entwurfs-Version,X, + 4,Nachrichten-Kopfsegment,,UNH,0054,00003,11A,,Ausgabe 2011 - A,X, + 5,Nachrichten-Kopfsegment,,UNH,0051,00003,UN,,UN/CEFACT,X, + 6,Nachrichten-Kopfsegment,,UNH,0057,00003,Versionsnummer derzugrundeliegendenBDEW-Nachrichtenbeschreibung,,S1.1a,X, + 7,Beginn der Nachricht,,BGM,,00004,,,,Muss, + 8,Beginn der Nachricht,,BGM,1001,00004,E03,,Änderungsmeldungen,, + 9,Beginn der Nachricht,,BGM,1001,,Z14,,Stammdaten der Markt-oder Messlokation,X, + 10,Beginn der Nachricht,,BGM,1004,00004,,,Dokumentennummer,X, + 11,Nachrichtendatum,,DTM,,00005,,,,Muss, + 12,Nachrichtendatum,,DTM,2005,00005,137,,Dokumenten-/Nachrichtendatum/-zeit,X, + 13,Nachrichtendatum,,DTM,2380,00005,,,"Datum oder Uhrzeit oderZeitspanne, Wert",X [931][494],"[494] Das hier genannte Datum muss der Zeitpunkt sein, zu dem das Dokument erstellt wurde, oder ein Zeitpunkt, der davor liegt + [931] Format: ZZZ = +00" + 14,Nachrichtendatum,,DTM,2379,00005,303,,CCYYMMDDHHMMZZZ,X, + 15,Referenz auf eine vorangegangene Anfrage,SG1,,,,,,,Muss, + 16,Referenz auf eine vorangegangene Anfrage,SG1,RFF,,00007,,,,Muss, + 17,Referenz auf eine vorangegangene Anfrage,SG1,RFF,1153,00007,AAV,,Nummer der Anfrage,X, + 18,Referenz auf eine vorangegangene Anfrage,SG1,RFF,1154,00007,,,"Referenz, Identifikation",X [503],[503] Hinweis: Angabe des BGM DE1004 aus der ORDERS + 19,MP-ID Absender,SG2,,,,,,,Muss, + 20,MP-ID Absender,SG2,NAD,,00008,,,,Muss, + 21,MP-ID Absender,SG2,NAD,3035,00008,MS,,Dokumenten-/Nachrichtenausstellerbzw. -absender,X, + 22,MP-ID Absender,SG2,NAD,3039,00008,,,MP-ID,X, + 23,MP-ID Absender,SG2,NAD,3055,00008,9,,GS1,X, + 24,MP-ID Absender,SG2,NAD,3055,,293,,"DE, BDEW(Bundesverband der",X, + 25,Ansprechpartner,SG3,,,,,,,Kann, + 26,Ansprechpartner,SG3,CTA,,00009,,,,Muss, + 27,Ansprechpartner,SG3,CTA,3139,00009,IC,,Informationskontakt,X, + 28,Ansprechpartner,SG3,CTA,3412,00009,,,Name vom Ansprechpartner,X, + 29,Kommunikationsverbindung,SG3,COM,,00010,,,,Muss, + 30,Kommunikationsverbindung,SG3,COM,3148,00010,,,Nummer / Adresse,X (([939][321]) ∨([940][322])) ∧[514],"[321] Wenn im DE3155 in demselben COM der Code EM vorhanden ist + [322] Wenn im DE3155 in demselben COM der Code TE / FX / AJ / AL vorhanden ist + [514] Hinweis: Es darf nur eine Information im DE3148 übermittelt werden + [939] Format: Die Zeichenkette muss die Zeichen @ und . enthalten + [940] Format: Die Zeichenkette muss mit dem Zeichen + beginnen und danach dürfen nur noch Ziffern folgen" + 31,Kommunikationsverbindung,SG3,COM,3155,00010,EM,,Elektronische Post,X [1P0..1], + 32,Kommunikationsverbindung,SG3,COM,3155,,FX,,Telefax,X [1P0..1], + 33,Kommunikationsverbindung,SG3,COM,3155,,TE,,Telefon,X [1P0..1], + 34,Kommunikationsverbindung,SG3,COM,3155,,AJ,,weiteres Telefon,X [1P0..1], + 35,Kommunikationsverbindung,SG3,COM,3155,,AL,,Handy,X [1P0..1], + 36,MP-ID Empfänger,SG2,,,,,,,Muss, + 37,MP-ID Empfänger,SG2,NAD,,00011,,,,Muss, + 38,MP-ID Empfänger,SG2,NAD,3035,00011,MR,,Nachrichtenempfänger,X, + 39,MP-ID Empfänger,SG2,NAD,3039,00011,,,MP-ID,X [280],[280] Nur MP-ID aus Sparte Strom + 40,MP-ID Empfänger,SG2,NAD,3055,00011,9,,GS1,X, + 41,MP-ID Empfänger,SG2,NAD,3055,,293,,"DE, BDEW(Bundesverband derEnergie- undWasserwirtschaft e.V.)",, + 42,Vorgang,SG4,,,,,,,Muss, + 43,Vorgang,SG4,IDE,,00020,,,,Muss, + 44,Vorgang,SG4,IDE,7495,00020,24,,Transaktion,X, + 45,Vorgang,SG4,IDE,7402,00020,,,Vorgangsnummer,X, + 46,"Änderung zum, Gültigkeit, Beginndatum",SG4,DTM,,00027,,,,Muss, + 47,"Änderung zum, Gültigkeit, Beginndatum",SG4,DTM,2005,00027,157,,"Gültigkeit, Beginndatum",X, + 48,"Änderung zum, Gültigkeit, Beginndatum",SG4,DTM,2380,00027,,,"Datum oder Uhrzeit oderZeitspanne, Wert",X [UB1], + 49,"Änderung zum, Gültigkeit, Beginndatum",SG4,DTM,2379,00027,303,,CCYYMMDDHHMMZZZ,X, + 50,Transaktionsgrund,SG4,STS,,00037,,,,,[2061] Segment bzw. Segmentgruppe ist genau einmal je SG4 IDE (Vorgang) anzugeben + 51,Transaktionsgrund,SG4,STS,9015,00037,7,,Transaktionsgrund,, + 52,Transaktionsgrund,SG4,STS,9013,00037,E03,,Wechsel,, + 53,Transaktionsgrund,SG4,STS,9013,,ZE3,,Stammdatenänderung,, + 54,Status der Antwort,SG4,STS,,00039,,,,,[249] Innerhalb eines SG4 IDE müssen alle DE1131 der SG4 STS+E01 den identischen Wert enthalten + 55,Status der Antwort,SG4,STS,9015,00039,E01,,Status der Antwort,, + 56,Status der Antwort,SG4,STS,9013,00039,,,Code des Prüfschritts,, + 57,Status der Antwort,SG4,STS,1131,00039,Codeliste Strom Nr.S_0091,,S_0091,, + 58,Marktlokation,SG5,,,,,,,Muss [2061],[2061] Segment bzw. Segmentgruppe ist genau einmal je SG4 IDE (Vorgang) anzugeben + 59,Marktlokation,SG5,LOC,,00051,,,,Muss, + 60,Marktlokation,SG5,LOC,3227,00051,Z16,,Marktlokation,X, + 61,Marktlokation,SG5,LOC,3225,00051,,,ID der Marktlokation,X [950],[950] Format: Marktlokations-ID + 62,Tranche,SG5,,,,,,,Soll [166] ∧[601],"[166] Wenn vorhanden + [601] Hinweis: Es ist die ID der Marktlokation und alle Identifikatoren der Messlokationen" + 63,Tranche,SG5,LOC,,00054,,,,Muss, + 64,Tranche,SG5,LOC,3227,00054,Z21,,Tranche,X, + 65,Tranche,SG5,LOC,3225,00054,,,ID der Tranche,X [950],[950] Format: Marktlokations-ID + 66,Messlokation,SG5,,,,,,,Muss [601],[601] Hinweis: Es ist die ID der Marktlokation und alle Identifikatoren der Messlokationen anzugeben. Sowie wenn vorhanden die Tranche/n der Marklokation + 67,Messlokation,SG5,LOC,,00055,,,,Muss, + 68,Messlokation,SG5,LOC,3227,00055,Z17,,Messlokation,X, + 69,Messlokation,SG5,LOC,3225,00055,,,ID der Messlokation,X [951],[951] Format: Zählpunktbezeichnung + 70,Prüfidentifikator,SG6,,,,,,,Muss, + 71,Prüfidentifikator,SG6,RFF,,00057,,,,Muss, + 72,Prüfidentifikator,SG6,RFF,1153,00057,Z13,,Prüfidentifikator,X, + 73,Prüfidentifikator,SG6,RFF,1154,00057,55074,,HKNR / Stammdaten aufeine ORDERS,X, + 74,Prüfidentifikator,SG6,RFF,1154,,55075,,HKNR / Stammdatenaufgrund einer Änderung,, + 75,Prüfidentifikator,SG6,RFF,1154,,55076,,HKNR / Antwort aufStammdatenänderung,, + 76,Referenz Vorgangsnummer (aus Anfragenachricht),SG6,,,,,,,, + 77,Referenz Vorgangsnummer (aus Anfragenachricht),SG6,RFF,,00058,,,,, + 78,Referenz Vorgangsnummer (aus Anfragenachricht),SG6,RFF,1153,00058,TN,,Transaktions-Referenznummer,, + 79,Referenz Vorgangsnummer (aus Anfragenachricht),SG6,RFF,1154,00058,,,Vorgangsnummer,, + 80,Daten der Marktlokation,SG8,,,,,,,Muss [2061],[2061] Segment bzw. Segmentgruppe ist genau einmal je SG4 IDE (Vorgang) anzugeben + 81,Daten der Marktlokation,SG8,SEQ,,00103,,,,Muss, + 82,Daten der Marktlokation,SG8,SEQ,1229,00103,Z01,,Daten der Marktlokation,X, + 83,Referenz auf die ID der Marktlokation,SG8,RFF,,00104,,,,Muss, + 84,Referenz auf die ID der Marktlokation,SG8,RFF,1153,00104,Z18,,Marktlokation,X, + 85,Referenz auf die ID der Marktlokation,SG8,RFF,1154,00104,,,ID der Marktlokation,X [950],[950] Format: Marktlokations-ID + 86,Zugeordnete Marktpartner,SG10,,,,,,,Muss [300],[300] Wenn SG8 SEQ+Z15 (Daten der Tranche) nicht vorhanden + 87,Zugeordnete Marktpartner,SG10,CCI,,00111,,,,Muss, + 88,Zugeordnete Marktpartner,SG10,CCI,7037,00111,ZB3,,ZugeordneterMarktpartner,X, + 89,Lieferant,SG10,CAV,,00113,,,,Muss, + 90,Lieferant,SG10,CAV,7111,00113,Z89,,LF,X, + 91,Lieferant,SG10,CAV,1131,00113,,,MP-ID,X [611],"[611] Hinweis: Wenn das Unternehmen NB die Aufgaben der Marktrolle LF wahrnimmt, ist die MP-ID des Unternehmens NB in der Marktrolle LF anzugeben" + 92,Bilanzkreis,SG10,,,,,,,Muss [2061]∧ [300],"[300] Wenn SG8 SEQ+Z15 (Daten der Tranche) nicht vorhanden + [2061] Segment bzw. Segmentgruppe ist genau einmal je SG4 IDE (Vorgang) anzugeben" + 93,Bilanzkreis,SG10,CCI,,00117,,,,Muss, + 94,Bilanzkreis,SG10,CCI,7059,00117,Z19,,Bilanzkreis,X, + 95,Bilanzkreis,SG10,CCI,7037,00117,,,Bilanzkreis,X, + 96,Zeitreihentyp,SG10,,,,,,,Muss [2061],[2061] Segment bzw. Segmentgruppe ist genau einmal je SG4 IDE (Vorgang) anzugeben + 97,Zeitreihentyp,SG10,CCI,,00121,,,,Muss, + 98,Zeitreihentyp,SG10,CCI,7059,00121,15,,Struktur,X, + 99,Zeitreihentyp,SG10,CCI,7037,00121,Z21,,Summenzeitreihentyp,X, + 100,Zeitreihentyp,SG10,CAV,,00122,,,,Muss, + 101,Zeitreihentyp,SG10,CAV,7111,00122,,,Code des Zeitreihentyps,X, + 102,Art der erzeugenden Marktlokation,SG10,,,,,,,Muss, + 103,Art der erzeugenden Marktlokation,SG10,CCI,,00137,,,,Muss, + 104,Art der erzeugenden Marktlokation,SG10,CCI,7037,00137,Z34,,Art der erzeugendenMarktlokation,X, + 105,Art der erzeugenden Marktlokation ,SG10,CAV,,00138,,,,Muss, + 106,Art der erzeugenden Marktlokation ,SG10,CAV,7111,00138,Z33,,EEG-Marktlokation ohneDV-Pflicht,X, + 107,Art der erzeugenden Marktlokation ,SG10,CAV,7111,,Z34,,KWKG-Marktlokationohne DV-Pflicht,X, + 108,Art der erzeugenden Marktlokation ,SG10,CAV,7111,,Z35,,sonstige Marktlokation,X, + 109,Art der erzeugenden Marktlokation ,SG10,CAV,7111,,Z37,,EEG-Marktlokation mitDV-Pflicht,X, + 110,Art der erzeugenden Marktlokation ,SG10,CAV,7111,,Z46,,KWKG-Marktlokation mitDV-Pflicht,X, + 111,Status der erzeugenden Marktlokation,SG10,,,,,,,Muss, + 112,Status der erzeugenden Marktlokation,SG10,CCI,,00148,,,,Muss, + 113,Status der erzeugenden Marktlokation,SG10,CCI,7059,00148,Z22,,Gesetzliche Kategorie,X, + 114,Status der erzeugenden Marktlokation,SG10,CCI,7037,00148,Z90,,EEG-Veräußerungsform:Ausfallvergütung,X [695], + 115,Status der erzeugenden Marktlokation,SG10,CCI,7037,,Z91,,EEG-Veräußerungsform:Marktprämie,X [696], + 116,Status der erzeugenden Marktlokation,SG10,CCI,7037,,Z92,,EEG-Veräußerungsform:Sonstiges,X [696], + 117,Status der erzeugenden Marktlokation,SG10,CCI,7037,,Z94,,KWKG-Vergütung,X [695],"[695] Hinweis: Verwendung, wenn Rolle LF einem Unternehmen NB zugeordnet ist + [696] Hinweis: Verwendung, nur wenn die Rolle LF nicht einem Unternehmen NB zugeordnet ist" + 118,Land der Förderung,SG10,,,,,,,Muss [240],[240] Wenn SG8 SEQ+Z01 (Daten der Marktlokation) CCI+Z22++Z91 (Status der erzeugenden Marktlokation: Veräußerungsform Geförderte Direktvermarktung bzw. Marktprämie) vorhanden + 119,Land der Förderung,SG10,CCI,,00149,,,,Muss, + 120,Land der Förderung,SG10,CCI,7059,00149,Z23,,Land der Förderung,X, + 121,Land der Förderung,SG10,CCI,7037,00149,,,Land der Förderung,X, + 122,Land der Förderung,SG10,CCI,1131,00149,LAND,,EDI@Energy Codelisteder europäischenLändercodes,X, + 123,Land der Förderung,SG10,CCI,3055,00149,293,,"DE, BDEW(Bundesverband derEnergie- undWasserwirtschaft e.V.)",X, + 124,OBIS-Daten der Marktlokation,SG8,,,,,,,Muss [300],[300] Wenn SG8 + 125,OBIS-Daten der Marktlokation,SG8,SEQ,,00198,,,,Muss, + 126,OBIS-Daten der Marktlokation,SG8,SEQ,1229,00198,Z02,,OBIS-Daten derMarktlokation,X, + 127,Referenz auf die ID der Marktlokation,SG8,RFF,,00199,,,,Muss, + 128,Referenz auf die ID der Marktlokation,SG8,RFF,1153,00199,Z18,,Marktlokation,X, + 129,Referenz auf die ID der Marktlokation,SG8,RFF,1154,00199,,,ID einer Marktlokation,X [950],[950] Format: Marktlokations-ID + 130,OBIS-Kennzahl der Marktlokation,SG8,PIA,,00200,,,,Muss, + 131,OBIS-Kennzahl der Marktlokation,SG8,PIA,4347,00200,5,,Produktidentifikation,X, + 132,OBIS-Kennzahl der Marktlokation,SG8,PIA,7140,00200,,,OBIS-Kennzahl der Marktlokation,X [314],"[314] Es sind alle OBIS- Kennzahlen gem. EDI@Energy Codeliste der OBIS-Kennzahlen und Medien für den deutschen Energiemarkt Kap. 3 anzugeben, welche an der Marktlokation erforderlich sind. Der Mindestumfang der OBIS-Kennzahlen ergibt sich aus den genannten Messprodukt-Codes dem Kap. 5.1 des Dokumentes ""Codeliste der Konfigurationen""" + 133,OBIS-Kennzahl der Marktlokation,SG8,PIA,7143,00200,SRW,,OBIS-Kennzahl,X, + 134,Daten der Tranche,SG8,,,,,,,Muss [2307],[2307] Für jede ID im SG5 LOC+Z21 (Tranche) DE3225 genau einmal anzugeben + 135,Daten der Tranche,SG8,SEQ,,00238,,,,Muss, + 136,Daten der Tranche,SG8,SEQ,1229,00238,Z15,,Daten der Tranche,X, + 137,Referenz auf die ID der Tranche,SG8,RFF,,00239,,,,Muss, + 138,Referenz auf die ID der Tranche,SG8,RFF,1153,00239,Z20,,Tranche,X, + 139,Referenz auf die ID der Tranche,SG8,RFF,1154,00239,,,ID der Tranche,X [950],[950] Format: Marktlokations-ID + 140,Prozentualer Anteil der Tranche an der erzeugenden Marktlokation,SG9,,,,,,,Muss [384],[384] Wenn SG10 CCI+Z37++ZD1 (Basis zur Bildung der Tranchengröße) (Prozentual) vorhanden + 141,Prozentualer Anteil der Tranche an der erzeugenden Marktlokation,SG9,QTY,,00242,,,,Muss, + 142,Prozentualer Anteil der Tranche an der erzeugenden Marktlokation,SG9,QTY,6063,00242,11,,Aufteilungsmenge,X, + 143,Prozentualer Anteil der Tranche an der erzeugenden Marktlokation,SG9,QTY,6060,00242,,,Mengenangabe in %,X [914] ∧[930] ∧[955],"[914] Format: Möglicher Wert: > 0 + [930] Format: max. 2 Nachkommastellen + [955] Format: Möglicher Wert: < 100" + 144,Prozentualer Anteil der Tranche an der erzeugenden Marktlokation,SG9,QTY,6411,00242,P1,,Prozent,X, + 145,Zugeordnete Marktpartner,SG10,,,,,,,Muss, + 146,Zugeordnete Marktpartner,SG10,CCI,,00243,,,,Muss, + 147,Zugeordnete Marktpartner,SG10,CCI,7037,00243,ZB3,,ZugeordneterMarktpartner,X, + 148,Lieferant,SG10,CAV,,00244,,,,Muss, + 149,Lieferant,SG10,CAV,7111,00244,Z89,,LF,X, + 150,Lieferant,SG10,CAV,1131,00244,,,MP-ID,X, + 151,Bilanzkreis,SG10,,,,,,,Muss, + 152,Bilanzkreis,SG10,CCI,,00245,,,,Muss, + 153,Bilanzkreis,SG10,CCI,7059,00245,Z19,,Bilanzkreis,X, + 154,Bilanzkreis,SG10,CCI,7037,00245,,,Bilanzkreis,X, + 155,Basis zur Bildung der Tranchengröße,SG10,,,,,,,Muss, + 156,Basis zur Bildung der Tranchengröße,SG10,CCI,,00248,,,,Muss, + 157,Basis zur Bildung der Tranchengröße,SG10,CCI,7059,00248,Z37,,Basis zur Bildung derTranchengröße,X, + 158,Basis zur Bildung der Tranchengröße,SG10,CCI,7037,00248,ZD1,,Prozentual,X, + 159,Basis zur Bildung der Tranchengröße,SG10,CCI,7037,,ZD2,,Aufteilungsfaktor aufBasis vonReferenzenträger/installierter Leistung,X, + 160,OBIS-Daten der Tranche,SG8,,,,,,,Muss [2311],"[2311] Für jede ID im SG5 LOC+Z21 (Tranche) DE3225, mindestens" + 161,OBIS-Daten der Tranche,SG8,SEQ,,00260,,,,Muss, + 162,OBIS-Daten der Tranche,SG8,SEQ,1229,00260,Z17,,OBIS-Daten der Tranche,X, + 163,Referenz auf die ID einer Tranche,SG8,RFF,,00261,,,,Muss, + 164,Referenz auf die ID einer Tranche,SG8,RFF,1153,00261,Z20,,Tranche,X, + 165,Referenz auf die ID einer Tranche,SG8,RFF,1154,00261,,,ID einer Tranche,X [950],[950] Format: Marktlokations-ID + 166,OBIS-Kennzahl der Tranche,SG8,PIA,,00262,,,,Muss, + 167,OBIS-Kennzahl der Tranche,SG8,PIA,4347,00262,5,,Produktidentifikation,X, + 168,OBIS-Kennzahl der Tranche,SG8,PIA,7140,00262,,,OBIS-Kennzahl der Tranche,X [269],[269] Es sind alle OBIS- Kennzahlen gem. EDI@Energy Codeliste der OBIS-Kennzahlen und Medien für den deutschen Energiemarkt Kap.3 anzugeben welche an der Tranche erforderlich sind + 169,OBIS-Kennzahl der Tranche,SG8,PIA,7143,00262,SRW,,OBIS-Kennzahl,X, + 170,Zähleinrichtungsdaten,SG8,,,,,,,Muss [2309],[2309] Für jede ID im SG5 LOC+Z17 (Messlokation) DE3225 mindestens einmal anzugeben + 171,Zähleinrichtungsdaten,SG8,SEQ,,00326,,,,Muss, + 172,Zähleinrichtungsdaten,SG8,SEQ,1229,00326,Z03,,Zähleinrichtungsdaten,X, + 173,Referenz auf die ID einer Messlokation,SG8,RFF,,00327,,,,Muss, + 174,Referenz auf die ID einer Messlokation,SG8,RFF,1153,00327,Z19,,Messlokation,X, + 175,Referenz auf die ID einer Messlokation,SG8,RFF,1154,00327,,,ID einer Messlokation,X [951],[951] Format: Zählpunktbezeichnung + 176,Referenz auf das Smartmeter-Gateway,SG8,RFF,,00328,,,,Soll [166] ∧[215],"[166] Wenn vorhanden + [215] Wenn in derselben SG8 SEQ+Z03 (Zähleinrichtungsdaten) SG10 CCI+++E13 CAV+MME (Zählertyp: mME) vorhanden" + 177,Referenz auf das Smartmeter-Gateway,SG8,RFF,1153,00328,Z14,,Smartmeter-Gateway,X, + 178,Referenz auf das Smartmeter-Gateway,SG8,RFF,1154,00328,,,Identifikation / Nummer desSmartmeter-Gateways,X, + 179,Zählertyp,SG10,,,,,,,Muss, + 180,Zählertyp,SG10,CCI,,00329,,,,Muss, + 181,Zählertyp,SG10,CCI,7037,00329,E13,,Zählertyp,X, + 182,Zählertyp,SG10,CAV,,00330,,,,Muss, + 183,Zählertyp,SG10,CAV,7111,00330,AHZ,,analoger Haushaltszähler(Drehstrom),X, + 184,Zählertyp,SG10,CAV,7111,,WSZ,,analogerWechselstromzähler,X, + 185,Zählertyp,SG10,CAV,7111,,LAZ,,Lastgangzähler,X, + 186,Zählertyp,SG10,CAV,7111,,MAZ,,Maximumzähler,X, + 187,Zählertyp,SG10,CAV,7111,,MME,,moderneMesseinrichtung nachMsbG,X, + 188,Zählertyp,SG10,CAV,7111,,EHZ,,elektronischerHaushaltszähler,X , + 189,Zählertyp,SG10,CAV,7111,,IVA,,Individuelle Abstimmung(Sonderausstattung),X, + 190,Identifikation / Nummer des Gerätes,SG10,CAV,,00331,,,,Muss, + 191,Identifikation / Nummer des Gerätes,SG10,CAV,7111,00331,Z30,,Gerätenummer,X, + 192,Identifikation / Nummer des Gerätes,SG10,CAV,7110,00331,,,Gerätenummer,X, + 193,Registeranzahl,SG10,CAV,,00332,,,,Muss [139],[139] Wenn SG10 CAV+IVA (Individuelle Abstimmung) nicht vorhanden + 194,Registeranzahl,SG10,CAV,7111,00332,ETZ,,Eintarif,X, + 195,Registeranzahl,SG10,CAV,7111,,ZTZ,,Zweitarif,X, + 196,Registeranzahl,SG10,CAV,7111,,NTZ,,Mehrtarif,X, + 197,Energierichtung,SG10,CAV,,00333,,,,Muss, + 198,Energierichtung,SG10,CAV,7111,00333,ERZ,,Einrichtungszähler,X, + 199,Energierichtung,SG10,CAV,7111,,ZRZ,,Zweirichtungszähler,X, + 200,OBIS-Daten der Zähleinrichtung / Smartmeter-Gateway,SG8,,,,,,,Muss([2287] ∧[121]) ∨,[121] Wenn in dem SEQ+Z03 (Zähleinrichtungsdaten) + 201,OBIS-Daten der Zähleinrichtung / Smartmeter-Gateway,SG8,SEQ,,00339,,,,Muss, + 202,OBIS-Daten der Zähleinrichtung / Smartmeter-Gateway,SG8,SEQ,1229,00339,Z20,,OBIS-Daten derZähleinrichtung,X, + 203,Referenz auf die Gerätenummer,SG8,RFF,,00340,,,,Muss [665],[665] Hinweis: Wenn ein Zähler mit einem SMGW parametriert ist werden an dem Zähler keine OBIS-Kennzahlen angegeben Hier gibt es nur OBIS Kennzahlen vom SMGW + 204,Referenz auf die Gerätenummer,SG8,RFF,1153,00340,MG,,Gerätenummer desZählers,X [441], + 205,Referenz auf die Gerätenummer,SG8,RFF,1153,,Z14,,Smartmeter-Gateway,X,[441] Wenn im SG8+SEQ+Z03 (Zähleinrichtungsdaten) für die in diesem RFF DE1154 genannte Gerätenummer eines Zählers das RFF+Z14 (Referenz auf das Smartmeter-Gateway) nicht vorhanden ist + 206,Referenz auf die Gerätenummer,SG8,RFF,1154,00340,,,Gerätenummer,X, + 207,Referenz auf die ID einer Messlokation,SG8,RFF,,00341,,,,Muss, + 208,Referenz auf die ID einer Messlokation,SG8,RFF,1153,00341,Z19,,Messlokation,X, + 209,Referenz auf die ID einer Messlokation,SG8,RFF,1154,00341,,,ID einer Messlokation,X [951],[951] Format: Zählpunktbezeichnung + 210,Konfigurations-ID,SG8,RFF,,00343,,,,Muss [402]∧ [420],"[402] Wenn in derselben SG8 SEQ+Z20 (OBIS- Daten der Zähleinrichtung / Smartmeter-Gateway) eine OBIS-Kennzahl der Werteart ""Zählerstand"" im PIA+5 vorhanden + [420] Wenn in dieser SG8 das RFF+Z14 (Smartmeter-Gateway) vorhanden ist" + 211,Konfigurations-ID,SG8,RFF,1153,00343,AGK,,Anwendungsreferenznummer,X, + 212,Konfigurations-ID,SG8,RFF,1154,00343,,,"Referenz, Identifikation",X, + 213,OBIS-Kennzahl der Zähleinrichtung / Smartmeter-Gateway,SG8,PIA,,00344,,,,Muss, + 214,OBIS-Kennzahl der Zähleinrichtung / Smartmeter-Gateway,SG8,PIA,4347,00344,5,,Produktidentifikation,X, + 215,OBIS-Kennzahl der Zähleinrichtung / Smartmeter-Gateway,SG8,PIA,7140,00344,,,OBIS-Kennzahl derZähleinrichtung,X [323],"[323] Es sind alle OBIS- Kennzahlen gem. EDI@Energy Codeliste der OBIS-Kennzahlen und Medien für den deutschen Energiemarkt Kap. 3. anzugeben, welche an der Zähleinrichtung genutzt werden. Der Mindestumfang der OBIS-Kennzahlen ergibt sich aus den genannten Messprodukt-Codes dem Kap. 5.1 des Dokumentes ""Codeliste der Konfigurationen""" + 216,OBIS-Kennzahl der Zähleinrichtung / Smartmeter-Gateway,SG8,PIA,7143,00344,SRW,,OBIS-Kennzahl,X, + 217,Wertegranularität,SG10,,,,,,,Muss [256],[256] Wenn in derselben SG8 SEQ+Z20 (OBIS- Daten der Zähleinrichtung / Smartmeter-Gateway) das PIA+5+1-b?:1.8.e / + 218,Wertegranularität,SG10,CCI,,00345,,,,Muss, + 219,Wertegranularität,SG10,CCI,7037,00345,ZE4,,Wertegranularität,X, + 220,Wertegranularität,SG10,CAV,,00346,,,,Muss, + 221,Wertegranularität,SG10,CAV,7111,00346,ZD9,,Jährlich,X, + 222,Wertegranularität,SG10,CAV,7111,,ZE8,,Halbjährlich,X, + 223,Wertegranularität,SG10,CAV,7111,,ZE9,,Quartalsweise,X, + 224,Wertegranularität,SG10,CAV,7111,,ZB7,,Monatlich,X, + 225,Vor- und Nachkommastellen des Zählwerks,SG10,,,,,,,Muss [273],[273] Wenn in derselben SG8 SEQ+Z20 (OBIS- Daten der Zähleinrichtung / Smartmeter-Gateway) das PIA+5+1-b?:1.8.e / 1-b?:2.8.e / 1-b?:3.8.e / 1-b?:4.8.e / 1-b?:5.8.e / 1-b?:6.8.e / 1-b?:7.8.e / 1-b?:8.8.e /  1-b?:1.8.63 vorhanden + 226,Vor- und Nachkommastellen des Zählwerks,SG10,CCI,,00349,,,,Muss, + 227,Vor- und Nachkommastellen des Zählwerks,SG10,CCI,7059,00349,11,,Produkt,X, + 228,Vor- und Nachkommastellen des Zählwerks,SG10,CCI,7037,00349,Z33,,Vor- undNachkommastellen desZählwerkes,X, + 229,Vor- und Nachkommastellen des Zählwerks,SG10,CAV,,00350,,,,Muss, + 230,Vor- und Nachkommastellen des Zählwerks,SG10,CAV,7110,00350,,,Angabe der Vorkommastelle,X, + 231,Vor- und Nachkommastellen des Zählwerks,SG10,CAV,7110,00350,,,Angabe der Nachkommastelle,X, + 232,Wandlerdaten,SG8,,,,,,,Soll [130],[130] Wenn an Messlokation vorhanden + 233,Wandlerdaten,SG8,SEQ,,00353,,,,Muss, + 234,Wandlerdaten,SG8,SEQ,1229,00353,Z04,,Wandler-Daten,X, + 235,Referenz auf die Gerätenummer,SG8,RFF,,00354,,,,Muss, + 236,Referenz auf die Gerätenummer,SG8,RFF,1153,00354,MG,,Gerätenummer desZählers,X, + 237,Referenz auf die Gerätenummer,SG8,RFF,1154,00354,,,Gerätenummer,X, + 238,Wandler,SG10,,,,,,,Muss, + 239,Wandler,SG10,CCI,,00355,,,,Muss, + 240,Wandler,SG10,CCI,7037,00355,Z25,,Wandler,X, + 241,Identifikation / Nummer des Gerätes,SG10,CAV,,00356,,,,Muss [2317]⊻ [2318],"[2317] Wenn in derselben SG8 SEQ+Z04 (Wandlerdaten) das SG10 CCI+++Z25 (Wandler) CAV+MIW/ MPW/MUW vorhanden, ist das Segment mindestens zweimal anzugeben + [2318] Wenn in derselben SG8 SEQ+Z04 (Wandlerdaten) das SG10 CCI+++Z25 (Wandler) CAV+MBW (Blockstromwandler) vorhanden, ist das Segment genau einmal anzugeben" + 242,Identifikation / Nummer des Gerätes,SG10,CAV,7111,00356,Z30,,Gerätenummer,X, + 243,Identifikation / Nummer des Gerätes,SG10,CAV,7110,00356,,,Gerätenummer,X, + 244,Wandlertyp und Faktor,SG10,CAV,,00357,,,,Muss, + 245,Wandlertyp und Faktor,SG10,CAV,7111,00357,MIW,,Messwandlersatz Strom,X, + 246,Wandlertyp und Faktor,SG10,CAV,7111,,MPW,,Kombimesswandlersatz(Strom und Spannung),X, + 247,Wandlertyp und Faktor,SG10,CAV,7111,,MBW,,Blockstromwandler,X, + 248,Wandlertyp und Faktor,SG10,CAV,7111,,MUW,,MesswandlersatzSpannung,X, + 249,Wandlertyp und Faktor,SG10,CAV,7110,00357,,,Wandlerfaktor,X [902][141],"[141] Wenn SG10 CAV+MIW/ MPW/ MBW vorhanden + [902] Format: Möglicher Wert: ≥ 0" + 250,Smartmeter-Gateway,SG8,,,,,,,Soll [130],[130] Wenn an Messlokation vorhanden + 251,Smartmeter-Gateway,SG8,SEQ,,00368,,,,Muss, + 252,Smartmeter-Gateway,SG8,SEQ,1229,00368,Z13,,Smartmeter-Gateway,X, + 253,Smartmeter-Gateway,SG10,,,,,,,Muss, + 254,Smartmeter-Gateway,SG10,CCI,,00369,,,,Muss, + 255,Smartmeter-Gateway,SG10,CCI,7037,00369,Z75,,Smartmeter-Gateway,X, + 256,Identifikation / Nummer des Gerätes,SG10,CAV,,00370,,,,Muss, + 257,Identifikation / Nummer des Gerätes,SG10,CAV,7111,00370,Z30,,Gerätenummer,X, + 258,Identifikation / Nummer des Gerätes,SG10,CAV,7110,00370,,,Gerätenummer,X [952],[952] Format: Gerätenummer nach DIN 43863-5 + 259,Daten der Steuerbox,SG8,,,,,,,Soll [133],[133] Wenn an der übermittelten Marktlokation / Messlokation vorhanden + 260,Daten der Steuerbox,SG8,SEQ,,00371,,,,Muss, + 261,Daten der Steuerbox,SG8,SEQ,1229,00371,Z14,,Steuerbox,X, + 262,Referenz auf das Smartmeter-Gateway,SG8,RFF,,00372,,,,Muss, + 263,Referenz auf das Smartmeter-Gateway,SG8,RFF,1153,00372,Z14,,Smartmeter-Gateway,X, + 264,Referenz auf das Smartmeter-Gateway,SG8,RFF,1154,00372,,,Identifikation / Nummer desSmartmeter-Gateways,X, + 265,Referenz auf die ID der Marktlokation,SG8,RFF,,00373,,,,Muss, + 266,Referenz auf die ID der Marktlokation,SG8,RFF,1153,00373,Z18,,Marktlokation,X, + 267,Referenz auf die ID der Marktlokation,SG8,RFF,1154,00373,,,ID einer Marktlokation,X [950],[950] Format: Marktlokations-ID + 268,Steuerbox,SG10,,,,,,,Muss, + 269,Steuerbox,SG10,CCI,,00374,,,,Muss, + 270,Steuerbox,SG10,CCI,7037,00374,Z76,,Steuerbox,X, + 271,Identifikation / Nummer des Gerätes,SG10,CAV,,00375,,,,Muss, + 272,Identifikation / Nummer des Gerätes,SG10,CAV,7111,00375,Z30,,Gerätenummer,X, + 273,Identifikation / Nummer des Gerätes,SG10,CAV,7110,00375,,,Gerätenummer,X [952],[952] Format: Gerätenummer nach DIN 43863-5 + 274,Beteiligter Marktpartner MP-ID,SG12,,,,,,,,"[198] Wenn SG4 STS+7++E03(Transaktion sgrund: Wechsel) vorhanden + [570] Hinweis:" + 275,Beteiligter Marktpartner MP-ID,SG12,NAD,,00533,,,,, + 276,Beteiligter Marktpartner MP-ID,SG12,NAD,3035,00533,VY,,andere zugehörige Partei,, + 277,Beteiligter Marktpartner MP-ID,SG12,NAD,3039,00533,,,MP-ID,, + 278,Beteiligter Marktpartner MP-ID,SG12,NAD,3055,00533,9,,GS1,, + 279,Beteiligter Marktpartner MP-ID,SG12,NAD,3055,,293,,"DE, BDEW(Bundesverband derEnergie- undWasserwirtschaft e.V.)",, + 280,Referenz auf die ID einer Marktlokation / Tranche,SG12,RFF,,00534,,,,, + 281,Referenz auf die ID einer Marktlokation / Tranche,SG12,RFF,1153,00534,Z18,,Marktlokation,, + 282,Referenz auf die ID einer Marktlokation / Tranche,SG12,RFF,1153,,Z20,,Tranche,, + 283,Referenz auf die ID einer Marktlokation / Tranche,SG12,RFF,1154,00534,,,ID einer Marktlokation / Tranche,,[950] Format: Marktlokations-ID + 284,Marktlokationsanschrift,SG12,,,,,,,Soll [170],[170] Wenn Anschrift der Marktlokation vorhanden + 285,Marktlokationsanschrift,SG12,NAD,,00535,,,,Muss, + 286,Marktlokationsanschrift,SG12,NAD,3035,00535,DP,,Lieferanschrift,X, + 287,Marktlokationsanschrift,SG12,NAD,3124,00535,,,Zusatzinformation zurIdentifizierung,K, + 288,Marktlokationsanschrift,SG12,NAD,3042,00535,,,Straße und Hausnummer oderPostfach,S [166]M [212],"[166] Wenn vorhanden + [212] Wenn im selben SG12 NAD DE3124 nicht vorhanden" + 289,Marktlokationsanschrift,SG12,NAD,3164,00535,,,Ort,X, + 290,Marktlokationsanschrift,SG12,NAD,3251,00535,,,Postleitzahl,X, + 291,Marktlokationsanschrift,SG12,NAD,3207,00535,,,"Ländername, Code",X, + 292,Nachrichten-Endesegment,,UNT,,00540,,,,Muss, + 293,Nachrichten-Endesegment,,UNT,0074,00540,,,Anzahl der Segmente in einerNachricht,X, + 294,Nachrichten-Endesegment,,UNT,0062,00540,,,Nachrichten-Referenznummer,X, + + ''' +# --- +# name: TestCli.test_kohlrahbi_cli_with_valid_arguments[55075] + ''' + ,Segmentname,Segmentgruppe,Segment,Datenelement,Segment ID,Code,Qualifier,Beschreibung,Bedingungsausdruck,Bedingung + 0,Nachrichten-Kopfsegment,,UNH,,00003,,,,Muss, + 1,Nachrichten-Kopfsegment,,UNH,0062,00003,,,Nachrichten-Referenznummer,X, + 2,Nachrichten-Kopfsegment,,UNH,0065,00003,UTILMD,,Netzanschluss-Stammdaten,X, + 3,Nachrichten-Kopfsegment,,UNH,0052,00003,D,,Entwurfs-Version,X, + 4,Nachrichten-Kopfsegment,,UNH,0054,00003,11A,,Ausgabe 2011 - A,X, + 5,Nachrichten-Kopfsegment,,UNH,0051,00003,UN,,UN/CEFACT,X, + 6,Nachrichten-Kopfsegment,,UNH,0057,00003,Versionsnummer derzugrundeliegendenBDEW-Nachrichtenbeschreibung,,S1.1a,X, + 7,Beginn der Nachricht,,BGM,,00004,,,,Muss, + 8,Beginn der Nachricht,,BGM,1001,00004,E03,,Änderungsmeldungen,X, + 9,Beginn der Nachricht,,BGM,1001,,Z14,,Stammdaten der Markt-oder Messlokation,, + 10,Beginn der Nachricht,,BGM,1004,00004,,,Dokumentennummer,X, + 11,Nachrichtendatum,,DTM,,00005,,,,Muss, + 12,Nachrichtendatum,,DTM,2005,00005,137,,Dokumenten-/Nachrichtendatum/-zeit,X, + 13,Nachrichtendatum,,DTM,2380,00005,,,"Datum oder Uhrzeit oderZeitspanne, Wert",X [931][494],"[494] Das hier genannte Datum muss der Zeitpunkt sein, zu dem das Dokument erstellt wurde, oder ein Zeitpunkt, der davor liegt + [931] Format: ZZZ = +00" + 14,Nachrichtendatum,,DTM,2379,00005,303,,CCYYMMDDHHMMZZZ,X, + 15,Referenz auf eine vorangegangene Anfrage,SG1,,,,,,,, + 16,Referenz auf eine vorangegangene Anfrage,SG1,RFF,,00007,,,,, + 17,Referenz auf eine vorangegangene Anfrage,SG1,RFF,1153,00007,AAV,,Nummer der Anfrage,, + 18,Referenz auf eine vorangegangene Anfrage,SG1,RFF,1154,00007,,,"Referenz, Identifikation",,[503] Hinweis: Angabe des BGM DE1004 aus der ORDERS + 19,MP-ID Absender,SG2,,,,,,,Muss, + 20,MP-ID Absender,SG2,NAD,,00008,,,,Muss, + 21,MP-ID Absender,SG2,NAD,3035,00008,MS,,Dokumenten-/Nachrichtenausstellerbzw. -absender,X, + 22,MP-ID Absender,SG2,NAD,3039,00008,,,MP-ID,X, + 23,MP-ID Absender,SG2,NAD,3055,00008,9,,GS1,X, + 24,MP-ID Absender,SG2,NAD,3055,,293,,"DE, BDEW(Bundesverband der",X, + 25,Ansprechpartner,SG3,,,,,,,Kann, + 26,Ansprechpartner,SG3,CTA,,00009,,,,Muss, + 27,Ansprechpartner,SG3,CTA,3139,00009,IC,,Informationskontakt,X, + 28,Ansprechpartner,SG3,CTA,3412,00009,,,Name vom Ansprechpartner,X, + 29,Kommunikationsverbindung,SG3,COM,,00010,,,,Muss, + 30,Kommunikationsverbindung,SG3,COM,3148,00010,,,Nummer / Adresse,X (([939][321]) ∨([940][322])) ∧[514],"[321] Wenn im DE3155 in demselben COM der Code EM vorhanden ist + [322] Wenn im DE3155 in demselben COM der Code TE / FX / AJ / AL vorhanden ist + [514] Hinweis: Es darf nur eine Information im DE3148 übermittelt werden + [939] Format: Die Zeichenkette muss die Zeichen @ und . enthalten + [940] Format: Die Zeichenkette muss mit dem Zeichen + beginnen und danach dürfen nur noch Ziffern folgen" + 31,Kommunikationsverbindung,SG3,COM,3155,00010,EM,,Elektronische Post,X [1P0..1], + 32,Kommunikationsverbindung,SG3,COM,3155,,FX,,Telefax,X [1P0..1], + 33,Kommunikationsverbindung,SG3,COM,3155,,TE,,Telefon,X [1P0..1], + 34,Kommunikationsverbindung,SG3,COM,3155,,AJ,,weiteres Telefon,X [1P0..1], + 35,Kommunikationsverbindung,SG3,COM,3155,,AL,,Handy,X [1P0..1], + 36,MP-ID Empfänger,SG2,,,,,,,Muss, + 37,MP-ID Empfänger,SG2,NAD,,00011,,,,Muss, + 38,MP-ID Empfänger,SG2,NAD,3035,00011,MR,,Nachrichtenempfänger,X, + 39,MP-ID Empfänger,SG2,NAD,3039,00011,,,MP-ID,X [280],[280] Nur MP-ID aus Sparte Strom + 40,MP-ID Empfänger,SG2,NAD,3055,00011,9,,GS1,X, + 41,MP-ID Empfänger,SG2,NAD,3055,,293,,"DE, BDEW(Bundesverband derEnergie- undWasserwirtschaft e.V.)",, + 42,Vorgang,SG4,,,,,,,Muss, + 43,Vorgang,SG4,IDE,,00020,,,,Muss, + 44,Vorgang,SG4,IDE,7495,00020,24,,Transaktion,X, + 45,Vorgang,SG4,IDE,7402,00020,,,Vorgangsnummer,X, + 46,"Änderung zum, Gültigkeit, Beginndatum",SG4,DTM,,00027,,,,Muss, + 47,"Änderung zum, Gültigkeit, Beginndatum",SG4,DTM,2005,00027,157,,"Gültigkeit, Beginndatum",X, + 48,"Änderung zum, Gültigkeit, Beginndatum",SG4,DTM,2380,00027,,,"Datum oder Uhrzeit oderZeitspanne, Wert",X [UB1], + 49,"Änderung zum, Gültigkeit, Beginndatum",SG4,DTM,2379,00027,303,,CCYYMMDDHHMMZZZ,X, + 50,Transaktionsgrund,SG4,STS,,00037,,,,Muss [2061],[2061] Segment bzw. Segmentgruppe ist genau einmal je SG4 IDE (Vorgang) anzugeben + 51,Transaktionsgrund,SG4,STS,9015,00037,7,,Transaktionsgrund,X, + 52,Transaktionsgrund,SG4,STS,9013,00037,E03,,Wechsel,X, + 53,Transaktionsgrund,SG4,STS,9013,,ZE3,,Stammdatenänderung,X, + 54,Status der Antwort,SG4,STS,,00039,,,,,[249] Innerhalb eines SG4 IDE müssen alle DE1131 der SG4 STS+E01 den identischen Wert enthalten + 55,Status der Antwort,SG4,STS,9015,00039,E01,,Status der Antwort,, + 56,Status der Antwort,SG4,STS,9013,00039,,,Code des Prüfschritts,, + 57,Status der Antwort,SG4,STS,1131,00039,Codeliste Strom Nr.S_0091,,S_0091,, + 58,Marktlokation,SG5,,,,,,,Muss [2061],[2061] Segment bzw. Segmentgruppe ist genau einmal je SG4 IDE (Vorgang) anzugeben + 59,Marktlokation,SG5,LOC,,00051,,,,Muss, + 60,Marktlokation,SG5,LOC,3227,00051,Z16,,Marktlokation,X, + 61,Marktlokation,SG5,LOC,3225,00051,,,ID der Marktlokation,X [950],[950] Format: Marktlokations-ID + 62,Tranche,SG5,,,,,,,Soll [166] ∧[601],"[166] Wenn vorhanden + [601] Hinweis: Es ist die ID der Marktlokation und alle Identifikatoren der Messlokationen" + 63,Tranche,SG5,LOC,,00054,,,,Muss, + 64,Tranche,SG5,LOC,3227,00054,Z21,,Tranche,X, + 65,Tranche,SG5,LOC,3225,00054,,,ID der Tranche,X [950],[950] Format: Marktlokations-ID + 66,Messlokation,SG5,,,,,,,Muss [601],[601] Hinweis: Es ist die ID der Marktlokation und alle Identifikatoren der Messlokationen anzugeben. Sowie wenn vorhanden die Tranche/n der Marklokation + 67,Messlokation,SG5,LOC,,00055,,,,Muss, + 68,Messlokation,SG5,LOC,3227,00055,Z17,,Messlokation,X, + 69,Messlokation,SG5,LOC,3225,00055,,,ID der Messlokation,X [951],[951] Format: Zählpunktbezeichnung + 70,Prüfidentifikator,SG6,,,,,,,Muss, + 71,Prüfidentifikator,SG6,RFF,,00057,,,,Muss, + 72,Prüfidentifikator,SG6,RFF,1153,00057,Z13,,Prüfidentifikator,X, + 73,Prüfidentifikator,SG6,RFF,1154,00057,55074,,HKNR / Stammdaten aufeine ORDERS,, + 74,Prüfidentifikator,SG6,RFF,1154,,55075,,HKNR / Stammdatenaufgrund einer Änderung,X, + 75,Prüfidentifikator,SG6,RFF,1154,,55076,,HKNR / Antwort aufStammdatenänderung,, + 76,Referenz Vorgangsnummer (aus Anfragenachricht),SG6,,,,,,,, + 77,Referenz Vorgangsnummer (aus Anfragenachricht),SG6,RFF,,00058,,,,, + 78,Referenz Vorgangsnummer (aus Anfragenachricht),SG6,RFF,1153,00058,TN,,Transaktions-Referenznummer,, + 79,Referenz Vorgangsnummer (aus Anfragenachricht),SG6,RFF,1154,00058,,,Vorgangsnummer,, + 80,Daten der Marktlokation,SG8,,,,,,,Muss [2061],[2061] Segment bzw. Segmentgruppe ist genau einmal je SG4 IDE (Vorgang) anzugeben + 81,Daten der Marktlokation,SG8,SEQ,,00103,,,,Muss, + 82,Daten der Marktlokation,SG8,SEQ,1229,00103,Z01,,Daten der Marktlokation,X, + 83,Referenz auf die ID der Marktlokation,SG8,RFF,,00104,,,,Muss, + 84,Referenz auf die ID der Marktlokation,SG8,RFF,1153,00104,Z18,,Marktlokation,X, + 85,Referenz auf die ID der Marktlokation,SG8,RFF,1154,00104,,,ID der Marktlokation,X [950],[950] Format: Marktlokations-ID + 86,Zugeordnete Marktpartner,SG10,,,,,,,Muss [300],[300] Wenn SG8 SEQ+Z15 (Daten der Tranche) nicht vorhanden + 87,Zugeordnete Marktpartner,SG10,CCI,,00111,,,,Muss, + 88,Zugeordnete Marktpartner,SG10,CCI,7037,00111,ZB3,,ZugeordneterMarktpartner,X, + 89,Lieferant,SG10,CAV,,00113,,,,Muss, + 90,Lieferant,SG10,CAV,7111,00113,Z89,,LF,X, + 91,Lieferant,SG10,CAV,1131,00113,,,MP-ID,X [611],"[611] Hinweis: Wenn das Unternehmen NB die Aufgaben der Marktrolle LF wahrnimmt, ist die MP-ID des Unternehmens NB in der Marktrolle LF anzugeben" + 92,Bilanzkreis,SG10,,,,,,,Muss [2061]∧ [300],"[300] Wenn SG8 SEQ+Z15 (Daten der Tranche) nicht vorhanden + [2061] Segment bzw. Segmentgruppe ist genau einmal je SG4 IDE (Vorgang) anzugeben" + 93,Bilanzkreis,SG10,CCI,,00117,,,,Muss, + 94,Bilanzkreis,SG10,CCI,7059,00117,Z19,,Bilanzkreis,X, + 95,Bilanzkreis,SG10,CCI,7037,00117,,,Bilanzkreis,X, + 96,Zeitreihentyp,SG10,,,,,,,Muss [2061],[2061] Segment bzw. Segmentgruppe ist genau einmal je SG4 IDE (Vorgang) anzugeben + 97,Zeitreihentyp,SG10,CCI,,00121,,,,Muss, + 98,Zeitreihentyp,SG10,CCI,7059,00121,15,,Struktur,X, + 99,Zeitreihentyp,SG10,CCI,7037,00121,Z21,,Summenzeitreihentyp,X, + 100,Zeitreihentyp,SG10,CAV,,00122,,,,Muss, + 101,Zeitreihentyp,SG10,CAV,7111,00122,,,Code des Zeitreihentyps,X, + 102,Art der erzeugenden Marktlokation,SG10,,,,,,,Muss, + 103,Art der erzeugenden Marktlokation,SG10,CCI,,00137,,,,Muss, + 104,Art der erzeugenden Marktlokation,SG10,CCI,7037,00137,Z34,,Art der erzeugendenMarktlokation,X, + 105,Art der erzeugenden Marktlokation ,SG10,CAV,,00138,,,,Muss, + 106,Art der erzeugenden Marktlokation ,SG10,CAV,7111,00138,Z33,,EEG-Marktlokation ohneDV-Pflicht,X, + 107,Art der erzeugenden Marktlokation ,SG10,CAV,7111,,Z34,,KWKG-Marktlokationohne DV-Pflicht,X, + 108,Art der erzeugenden Marktlokation ,SG10,CAV,7111,,Z35,,sonstige Marktlokation,X, + 109,Art der erzeugenden Marktlokation ,SG10,CAV,7111,,Z37,,EEG-Marktlokation mitDV-Pflicht,X, + 110,Art der erzeugenden Marktlokation ,SG10,CAV,7111,,Z46,,KWKG-Marktlokation mitDV-Pflicht,X, + 111,Status der erzeugenden Marktlokation,SG10,,,,,,,Muss, + 112,Status der erzeugenden Marktlokation,SG10,CCI,,00148,,,,Muss, + 113,Status der erzeugenden Marktlokation,SG10,CCI,7059,00148,Z22,,Gesetzliche Kategorie,X, + 114,Status der erzeugenden Marktlokation,SG10,CCI,7037,00148,Z90,,EEG-Veräußerungsform:Ausfallvergütung,X [695], + 115,Status der erzeugenden Marktlokation,SG10,CCI,7037,,Z91,,EEG-Veräußerungsform:Marktprämie,X [696], + 116,Status der erzeugenden Marktlokation,SG10,CCI,7037,,Z92,,EEG-Veräußerungsform:Sonstiges,X [696], + 117,Status der erzeugenden Marktlokation,SG10,CCI,7037,,Z94,,KWKG-Vergütung,X [695],"[695] Hinweis: Verwendung, wenn Rolle LF einem Unternehmen NB zugeordnet ist + [696] Hinweis: Verwendung, nur wenn die Rolle LF nicht einem Unternehmen NB zugeordnet ist" + 118,Land der Förderung,SG10,,,,,,,Muss [240],[240] Wenn SG8 SEQ+Z01 (Daten der Marktlokation) CCI+Z22++Z91 (Status der erzeugenden Marktlokation: Veräußerungsform Geförderte Direktvermarktung bzw. Marktprämie) vorhanden + 119,Land der Förderung,SG10,CCI,,00149,,,,Muss, + 120,Land der Förderung,SG10,CCI,7059,00149,Z23,,Land der Förderung,X, + 121,Land der Förderung,SG10,CCI,7037,00149,,,Land der Förderung,X, + 122,Land der Förderung,SG10,CCI,1131,00149,LAND,,EDI@Energy Codelisteder europäischenLändercodes,X, + 123,Land der Förderung,SG10,CCI,3055,00149,293,,"DE, BDEW(Bundesverband derEnergie- undWasserwirtschaft e.V.)",X, + 124,OBIS-Daten der Marktlokation,SG8,,,,,,,Muss [300],[300] Wenn SG8 + 125,OBIS-Daten der Marktlokation,SG8,SEQ,,00198,,,,Muss, + 126,OBIS-Daten der Marktlokation,SG8,SEQ,1229,00198,Z02,,OBIS-Daten derMarktlokation,X, + 127,Referenz auf die ID der Marktlokation,SG8,RFF,,00199,,,,Muss, + 128,Referenz auf die ID der Marktlokation,SG8,RFF,1153,00199,Z18,,Marktlokation,X, + 129,Referenz auf die ID der Marktlokation,SG8,RFF,1154,00199,,,ID einer Marktlokation,X [950],[950] Format: Marktlokations-ID + 130,OBIS-Kennzahl der Marktlokation,SG8,PIA,,00200,,,,Muss, + 131,OBIS-Kennzahl der Marktlokation,SG8,PIA,4347,00200,5,,Produktidentifikation,X, + 132,OBIS-Kennzahl der Marktlokation,SG8,PIA,7140,00200,,,OBIS-Kennzahl der Marktlokation,X [314],"[314] Es sind alle OBIS- Kennzahlen gem. EDI@Energy Codeliste der OBIS-Kennzahlen und Medien für den deutschen Energiemarkt Kap. 3 anzugeben, welche an der Marktlokation erforderlich sind. Der Mindestumfang der OBIS-Kennzahlen ergibt sich aus den genannten Messprodukt-Codes dem Kap. 5.1 des Dokumentes ""Codeliste der Konfigurationen""" + 133,OBIS-Kennzahl der Marktlokation,SG8,PIA,7143,00200,SRW,,OBIS-Kennzahl,X, + 134,Daten der Tranche,SG8,,,,,,,Muss [2307],[2307] Für jede ID im SG5 LOC+Z21 (Tranche) DE3225 genau einmal anzugeben + 135,Daten der Tranche,SG8,SEQ,,00238,,,,Muss, + 136,Daten der Tranche,SG8,SEQ,1229,00238,Z15,,Daten der Tranche,X, + 137,Referenz auf die ID der Tranche,SG8,RFF,,00239,,,,Muss, + 138,Referenz auf die ID der Tranche,SG8,RFF,1153,00239,Z20,,Tranche,X, + 139,Referenz auf die ID der Tranche,SG8,RFF,1154,00239,,,ID der Tranche,X [950],[950] Format: Marktlokations-ID + 140,Prozentualer Anteil der Tranche an der erzeugenden Marktlokation,SG9,,,,,,,Muss [384],[384] Wenn SG10 CCI+Z37++ZD1 (Basis zur Bildung der Tranchengröße) (Prozentual) vorhanden + 141,Prozentualer Anteil der Tranche an der erzeugenden Marktlokation,SG9,QTY,,00242,,,,Muss, + 142,Prozentualer Anteil der Tranche an der erzeugenden Marktlokation,SG9,QTY,6063,00242,11,,Aufteilungsmenge,X, + 143,Prozentualer Anteil der Tranche an der erzeugenden Marktlokation,SG9,QTY,6060,00242,,,Mengenangabe in %,X [914] ∧[930] ∧[955],"[914] Format: Möglicher Wert: > 0 + [930] Format: max. 2 Nachkommastellen + [955] Format: Möglicher Wert: < 100" + 144,Prozentualer Anteil der Tranche an der erzeugenden Marktlokation,SG9,QTY,6411,00242,P1,,Prozent,X, + 145,Zugeordnete Marktpartner,SG10,,,,,,,Muss, + 146,Zugeordnete Marktpartner,SG10,CCI,,00243,,,,Muss, + 147,Zugeordnete Marktpartner,SG10,CCI,7037,00243,ZB3,,ZugeordneterMarktpartner,X, + 148,Lieferant,SG10,CAV,,00244,,,,Muss, + 149,Lieferant,SG10,CAV,7111,00244,Z89,,LF,X, + 150,Lieferant,SG10,CAV,1131,00244,,,MP-ID,X, + 151,Bilanzkreis,SG10,,,,,,,Muss, + 152,Bilanzkreis,SG10,CCI,,00245,,,,Muss, + 153,Bilanzkreis,SG10,CCI,7059,00245,Z19,,Bilanzkreis,X, + 154,Bilanzkreis,SG10,CCI,7037,00245,,,Bilanzkreis,X, + 155,Basis zur Bildung der Tranchengröße,SG10,,,,,,,Muss, + 156,Basis zur Bildung der Tranchengröße,SG10,CCI,,00248,,,,Muss, + 157,Basis zur Bildung der Tranchengröße,SG10,CCI,7059,00248,Z37,,Basis zur Bildung derTranchengröße,X, + 158,Basis zur Bildung der Tranchengröße,SG10,CCI,7037,00248,ZD1,,Prozentual,X, + 159,Basis zur Bildung der Tranchengröße,SG10,CCI,7037,,ZD2,,Aufteilungsfaktor aufBasis vonReferenzenträger/installierter Leistung,X, + 160,OBIS-Daten der Tranche,SG8,,,,,,,Muss [2311],"[2311] Für jede ID im SG5 LOC+Z21 (Tranche) DE3225, mindestens" + 161,OBIS-Daten der Tranche,SG8,SEQ,,00260,,,,Muss, + 162,OBIS-Daten der Tranche,SG8,SEQ,1229,00260,Z17,,OBIS-Daten der Tranche,X, + 163,Referenz auf die ID einer Tranche,SG8,RFF,,00261,,,,Muss, + 164,Referenz auf die ID einer Tranche,SG8,RFF,1153,00261,Z20,,Tranche,X, + 165,Referenz auf die ID einer Tranche,SG8,RFF,1154,00261,,,ID einer Tranche,X [950],[950] Format: Marktlokations-ID + 166,OBIS-Kennzahl der Tranche,SG8,PIA,,00262,,,,Muss, + 167,OBIS-Kennzahl der Tranche,SG8,PIA,4347,00262,5,,Produktidentifikation,X, + 168,OBIS-Kennzahl der Tranche,SG8,PIA,7140,00262,,,OBIS-Kennzahl der Tranche,X [269],[269] Es sind alle OBIS- Kennzahlen gem. EDI@Energy Codeliste der OBIS-Kennzahlen und Medien für den deutschen Energiemarkt Kap.3 anzugeben welche an der Tranche erforderlich sind + 169,OBIS-Kennzahl der Tranche,SG8,PIA,7143,00262,SRW,,OBIS-Kennzahl,X, + 170,Zähleinrichtungsdaten,SG8,,,,,,,Muss [2309],[2309] Für jede ID im SG5 LOC+Z17 (Messlokation) DE3225 mindestens einmal anzugeben + 171,Zähleinrichtungsdaten,SG8,SEQ,,00326,,,,Muss, + 172,Zähleinrichtungsdaten,SG8,SEQ,1229,00326,Z03,,Zähleinrichtungsdaten,X, + 173,Referenz auf die ID einer Messlokation,SG8,RFF,,00327,,,,Muss, + 174,Referenz auf die ID einer Messlokation,SG8,RFF,1153,00327,Z19,,Messlokation,X, + 175,Referenz auf die ID einer Messlokation,SG8,RFF,1154,00327,,,ID einer Messlokation,X [951],[951] Format: Zählpunktbezeichnung + 176,Referenz auf das Smartmeter-Gateway,SG8,RFF,,00328,,,,Soll [166] ∧[215],"[166] Wenn vorhanden + [215] Wenn in derselben SG8 SEQ+Z03 (Zähleinrichtungsdaten) SG10 CCI+++E13 CAV+MME (Zählertyp: mME) vorhanden" + 177,Referenz auf das Smartmeter-Gateway,SG8,RFF,1153,00328,Z14,,Smartmeter-Gateway,X, + 178,Referenz auf das Smartmeter-Gateway,SG8,RFF,1154,00328,,,Identifikation / Nummer desSmartmeter-Gateways,X, + 179,Zählertyp,SG10,,,,,,,Muss, + 180,Zählertyp,SG10,CCI,,00329,,,,Muss, + 181,Zählertyp,SG10,CCI,7037,00329,E13,,Zählertyp,X, + 182,Zählertyp,SG10,CAV,,00330,,,,Muss, + 183,Zählertyp,SG10,CAV,7111,00330,AHZ,,analoger Haushaltszähler(Drehstrom),X, + 184,Zählertyp,SG10,CAV,7111,,WSZ,,analogerWechselstromzähler,X, + 185,Zählertyp,SG10,CAV,7111,,LAZ,,Lastgangzähler,X, + 186,Zählertyp,SG10,CAV,7111,,MAZ,,Maximumzähler,X, + 187,Zählertyp,SG10,CAV,7111,,MME,,moderneMesseinrichtung nachMsbG,X, + 188,Zählertyp,SG10,CAV,7111,,EHZ,,elektronischerHaushaltszähler,X, + 189,Zählertyp,SG10,CAV,7111,,IVA,,Individuelle Abstimmung(Sonderausstattung),X, + 190,Identifikation / Nummer des Gerätes,SG10,CAV,,00331,,,,Muss, + 191,Identifikation / Nummer des Gerätes,SG10,CAV,7111,00331,Z30,,Gerätenummer,X, + 192,Identifikation / Nummer des Gerätes,SG10,CAV,7110,00331,,,Gerätenummer,X, + 193,Registeranzahl,SG10,CAV,,00332,,,,Muss [139],[139] Wenn SG10 CAV+IVA (Individuelle Abstimmung) nicht vorhanden + 194,Registeranzahl,SG10,CAV,7111,00332,ETZ,,Eintarif,X, + 195,Registeranzahl,SG10,CAV,7111,,ZTZ,,Zweitarif,X, + 196,Registeranzahl,SG10,CAV,7111,,NTZ,,Mehrtarif,X, + 197,Energierichtung,SG10,CAV,,00333,,,,Muss, + 198,Energierichtung,SG10,CAV,7111,00333,ERZ,,Einrichtungszähler,X, + 199,Energierichtung,SG10,CAV,7111,,ZRZ,,Zweirichtungszähler,X, + 200,OBIS-Daten der Zähleinrichtung / Smartmeter-Gateway,SG8,,,,,,,Muss([2287] ∧[121]) ∨,[121] Wenn in dem SEQ+Z03 (Zähleinrichtungsdaten) + 201,OBIS-Daten der Zähleinrichtung / Smartmeter-Gateway,SG8,SEQ,,00339,,,,Muss, + 202,OBIS-Daten der Zähleinrichtung / Smartmeter-Gateway,SG8,SEQ,1229,00339,Z20,,OBIS-Daten derZähleinrichtung,X, + 203,Referenz auf die Gerätenummer,SG8,RFF,,00340,,,,Muss [665],[665] Hinweis: Wenn ein Zähler mit einem SMGW parametriert ist werden an dem Zähler keine OBIS-Kennzahlen angegeben Hier gibt es nur OBIS Kennzahlen vom SMGW + 204,Referenz auf die Gerätenummer,SG8,RFF,1153,00340,MG,,Gerätenummer desZählers,X [441], + 205,Referenz auf die Gerätenummer,SG8,RFF,1153,,Z14,,Smartmeter-Gateway,X,[441] Wenn im SG8+SEQ+Z03 (Zähleinrichtungsdaten) für die in diesem RFF DE1154 genannte Gerätenummer eines Zählers das RFF+Z14 (Referenz auf das Smartmeter-Gateway) nicht vorhanden ist + 206,Referenz auf die Gerätenummer,SG8,RFF,1154,00340,,,Gerätenummer,X, + 207,Referenz auf die ID einer Messlokation,SG8,RFF,,00341,,,,Muss, + 208,Referenz auf die ID einer Messlokation,SG8,RFF,1153,00341,Z19,,Messlokation,X, + 209,Referenz auf die ID einer Messlokation,SG8,RFF,1154,00341,,,ID einer Messlokation,X [951],[951] Format: Zählpunktbezeichnung + 210,Konfigurations-ID,SG8,RFF,,00343,,,,Muss [402]∧ [420],"[402] Wenn in derselben SG8 SEQ+Z20 (OBIS- Daten der Zähleinrichtung / Smartmeter-Gateway) eine OBIS-Kennzahl der Werteart ""Zählerstand"" im PIA+5 vorhanden + [420] Wenn in dieser SG8 das RFF+Z14 (Smartmeter-Gateway) vorhanden ist" + 211,Konfigurations-ID,SG8,RFF,1153,00343,AGK,,Anwendungsreferenznummer,X, + 212,Konfigurations-ID,SG8,RFF,1154,00343,,,"Referenz, Identifikation",X, + 213,OBIS-Kennzahl der Zähleinrichtung / Smartmeter-Gateway,SG8,PIA,,00344,,,,Muss, + 214,OBIS-Kennzahl der Zähleinrichtung / Smartmeter-Gateway,SG8,PIA,4347,00344,5,,Produktidentifikation,X, + 215,OBIS-Kennzahl der Zähleinrichtung / Smartmeter-Gateway,SG8,PIA,7140,00344,,,OBIS-Kennzahl derZähleinrichtung,X [323],"[323] Es sind alle OBIS- Kennzahlen gem. EDI@Energy Codeliste der OBIS-Kennzahlen und Medien für den deutschen Energiemarkt Kap. 3. anzugeben, welche an der Zähleinrichtung genutzt werden. Der Mindestumfang der OBIS-Kennzahlen ergibt sich aus den genannten Messprodukt-Codes dem Kap. 5.1 des Dokumentes ""Codeliste der Konfigurationen""" + 216,OBIS-Kennzahl der Zähleinrichtung / Smartmeter-Gateway,SG8,PIA,7143,00344,SRW,,OBIS-Kennzahl,X, + 217,Wertegranularität,SG10,,,,,,,Muss [256],[256] Wenn in derselben SG8 SEQ+Z20 (OBIS- Daten der Zähleinrichtung / Smartmeter-Gateway) das PIA+5+1-b?:1.8.e / + 218,Wertegranularität,SG10,CCI,,00345,,,,Muss, + 219,Wertegranularität,SG10,CCI,7037,00345,ZE4,,Wertegranularität,X, + 220,Wertegranularität,SG10,CAV,,00346,,,,Muss, + 221,Wertegranularität,SG10,CAV,7111,00346,ZD9,,Jährlich,X, + 222,Wertegranularität,SG10,CAV,7111,,ZE8,,Halbjährlich,X, + 223,Wertegranularität,SG10,CAV,7111,,ZE9,,Quartalsweise,X, + 224,Wertegranularität,SG10,CAV,7111,,ZB7,,Monatlich,X, + 225,Vor- und Nachkommastellen des Zählwerks,SG10,,,,,,,Muss [273],[273] Wenn in derselben SG8 SEQ+Z20 (OBIS- Daten der Zähleinrichtung / Smartmeter-Gateway) das PIA+5+1-b?:1.8.e / 1-b?:2.8.e / 1-b?:3.8.e / 1-b?:4.8.e / 1-b?:5.8.e / 1-b?:6.8.e / 1-b?:7.8.e / 1-b?:8.8.e /  1-b?:1.8.63 vorhanden + 226,Vor- und Nachkommastellen des Zählwerks,SG10,CCI,,00349,,,,Muss, + 227,Vor- und Nachkommastellen des Zählwerks,SG10,CCI,7059,00349,11,,Produkt,X, + 228,Vor- und Nachkommastellen des Zählwerks,SG10,CCI,7037,00349,Z33,,Vor- undNachkommastellen desZählwerkes,X, + 229,Vor- und Nachkommastellen des Zählwerks,SG10,CAV,,00350,,,,Muss, + 230,Vor- und Nachkommastellen des Zählwerks,SG10,CAV,7110,00350,,,Angabe der Vorkommastelle,X, + 231,Vor- und Nachkommastellen des Zählwerks,SG10,CAV,7110,00350,,,Angabe der Nachkommastelle,X, + 232,Wandlerdaten,SG8,,,,,,,Soll [130],[130] Wenn an Messlokation vorhanden + 233,Wandlerdaten,SG8,SEQ,,00353,,,,Muss, + 234,Wandlerdaten,SG8,SEQ,1229,00353,Z04,,Wandler-Daten,X, + 235,Referenz auf die Gerätenummer,SG8,RFF,,00354,,,,Muss, + 236,Referenz auf die Gerätenummer,SG8,RFF,1153,00354,MG,,Gerätenummer desZählers,X, + 237,Referenz auf die Gerätenummer,SG8,RFF,1154,00354,,,Gerätenummer,X, + 238,Wandler,SG10,,,,,,,Muss, + 239,Wandler,SG10,CCI,,00355,,,,Muss, + 240,Wandler,SG10,CCI,7037,00355,Z25,,Wandler,X, + 241,Identifikation / Nummer des Gerätes,SG10,CAV,,00356,,,,Muss [2317]⊻ [2318],"[2317] Wenn in derselben SG8 SEQ+Z04 (Wandlerdaten) das SG10 CCI+++Z25 (Wandler) CAV+MIW/ MPW/MUW vorhanden, ist das Segment mindestens zweimal anzugeben + [2318] Wenn in derselben SG8 SEQ+Z04 (Wandlerdaten) das SG10 CCI+++Z25 (Wandler) CAV+MBW (Blockstromwandler) vorhanden, ist das Segment genau einmal anzugeben" + 242,Identifikation / Nummer des Gerätes,SG10,CAV,7111,00356,Z30,,Gerätenummer,X, + 243,Identifikation / Nummer des Gerätes,SG10,CAV,7110,00356,,,Gerätenummer,X, + 244,Wandlertyp und Faktor,SG10,CAV,,00357,,,,Muss, + 245,Wandlertyp und Faktor,SG10,CAV,7111,00357,MIW,,Messwandlersatz Strom,X, + 246,Wandlertyp und Faktor,SG10,CAV,7111,,MPW,,Kombimesswandlersatz(Strom und Spannung),X, + 247,Wandlertyp und Faktor,SG10,CAV,7111,,MBW,,Blockstromwandler,X, + 248,Wandlertyp und Faktor,SG10,CAV,7111,,MUW,,MesswandlersatzSpannung,X, + 249,Wandlertyp und Faktor,SG10,CAV,7110,00357,,,Wandlerfaktor,X [902][141],"[141] Wenn SG10 CAV+MIW/ MPW/ MBW vorhanden + [902] Format: Möglicher Wert: ≥ 0" + 250,Smartmeter-Gateway,SG8,,,,,,,Soll [130],[130] Wenn an Messlokation vorhanden + 251,Smartmeter-Gateway,SG8,SEQ,,00368,,,,Muss, + 252,Smartmeter-Gateway,SG8,SEQ,1229,00368,Z13,,Smartmeter-Gateway,X, + 253,Smartmeter-Gateway,SG10,,,,,,,Muss, + 254,Smartmeter-Gateway,SG10,CCI,,00369,,,,Muss, + 255,Smartmeter-Gateway,SG10,CCI,7037,00369,Z75,,Smartmeter-Gateway,X, + 256,Identifikation / Nummer des Gerätes,SG10,CAV,,00370,,,,Muss, + 257,Identifikation / Nummer des Gerätes,SG10,CAV,7111,00370,Z30,,Gerätenummer,X, + 258,Identifikation / Nummer des Gerätes,SG10,CAV,7110,00370,,,Gerätenummer,X [952],[952] Format: Gerätenummer nach DIN 43863-5 + 259,Daten der Steuerbox,SG8,,,,,,,Soll [133],[133] Wenn an der übermittelten Marktlokation / Messlokation vorhanden + 260,Daten der Steuerbox,SG8,SEQ,,00371,,,,Muss, + 261,Daten der Steuerbox,SG8,SEQ,1229,00371,Z14,,Steuerbox,X, + 262,Referenz auf das Smartmeter-Gateway,SG8,RFF,,00372,,,,Muss, + 263,Referenz auf das Smartmeter-Gateway,SG8,RFF,1153,00372,Z14,,Smartmeter-Gateway,X, + 264,Referenz auf das Smartmeter-Gateway,SG8,RFF,1154,00372,,,Identifikation / Nummer desSmartmeter-Gateways,X, + 265,Referenz auf die ID der Marktlokation,SG8,RFF,,00373,,,,Muss, + 266,Referenz auf die ID der Marktlokation,SG8,RFF,1153,00373,Z18,,Marktlokation,X, + 267,Referenz auf die ID der Marktlokation,SG8,RFF,1154,00373,,,ID einer Marktlokation,X [950],[950] Format: Marktlokations-ID + 268,Steuerbox,SG10,,,,,,,Muss, + 269,Steuerbox,SG10,CCI,,00374,,,,Muss, + 270,Steuerbox,SG10,CCI,7037,00374,Z76,,Steuerbox,X, + 271,Identifikation / Nummer des Gerätes,SG10,CAV,,00375,,,,Muss, + 272,Identifikation / Nummer des Gerätes,SG10,CAV,7111,00375,Z30,,Gerätenummer,X, + 273,Identifikation / Nummer des Gerätes,SG10,CAV,7110,00375,,,Gerätenummer,X [952],[952] Format: Gerätenummer nach DIN 43863-5 + 274,Beteiligter Marktpartner MP-ID,SG12,,,,,,,Muss [198]∧ [570],"[198] Wenn SG4 STS+7++E03(Transaktion sgrund: Wechsel) vorhanden + [570] Hinweis:" + 275,Beteiligter Marktpartner MP-ID,SG12,NAD,,00533,,,,Muss, + 276,Beteiligter Marktpartner MP-ID,SG12,NAD,3035,00533,VY,,andere zugehörige Partei,X, + 277,Beteiligter Marktpartner MP-ID,SG12,NAD,3039,00533,,,MP-ID,X, + 278,Beteiligter Marktpartner MP-ID,SG12,NAD,3055,00533,9,,GS1,X, + 279,Beteiligter Marktpartner MP-ID,SG12,NAD,3055,,293,,"DE, BDEW(Bundesverband derEnergie- undWasserwirtschaft e.V.)",X, + 280,Referenz auf die ID einer Marktlokation / Tranche,SG12,RFF,,00534,,,,Muss, + 281,Referenz auf die ID einer Marktlokation / Tranche,SG12,RFF,1153,00534,Z18,,Marktlokation,X, + 282,Referenz auf die ID einer Marktlokation / Tranche,SG12,RFF,1153,,Z20,,Tranche,X, + 283,Referenz auf die ID einer Marktlokation / Tranche,SG12,RFF,1154,00534,,,ID einer Marktlokation / Tranche,X [950],[950] Format: Marktlokations-ID + 284,Marktlokationsanschrift,SG12,,,,,,,Soll [170],[170] Wenn Anschrift der Marktlokation vorhanden + 285,Marktlokationsanschrift,SG12,NAD,,00535,,,,Muss, + 286,Marktlokationsanschrift,SG12,NAD,3035,00535,DP,,Lieferanschrift,X, + 287,Marktlokationsanschrift,SG12,NAD,3124,00535,,,Zusatzinformation zurIdentifizierung,K, + 288,Marktlokationsanschrift,SG12,NAD,3042,00535,,,Straße und Hausnummer oderPostfach,S [166]M [212],"[166] Wenn vorhanden + [212] Wenn im selben SG12 NAD DE3124 nicht vorhanden" + 289,Marktlokationsanschrift,SG12,NAD,3164,00535,,,Ort,X, + 290,Marktlokationsanschrift,SG12,NAD,3251,00535,,,Postleitzahl,X, + 291,Marktlokationsanschrift,SG12,NAD,3207,00535,,,"Ländername, Code",X, + 292,Nachrichten-Endesegment,,UNT,,00540,,,,Muss, + 293,Nachrichten-Endesegment,,UNT,0074,00540,,,Anzahl der Segmente in einerNachricht,X, + 294,Nachrichten-Endesegment,,UNT,0062,00540,,,Nachrichten-Referenznummer,X, + + ''' +# --- +# name: TestCli.test_kohlrahbi_cli_with_valid_arguments[55077] + ''' + ,Segmentname,Segmentgruppe,Segment,Datenelement,Segment ID,Code,Qualifier,Beschreibung,Bedingungsausdruck,Bedingung + 0,Nachrichten-Kopfsegment,,UNH,,00003,,,,Muss, + 1,Nachrichten-Kopfsegment,,UNH,0062,00003,,,Nachrichten-Referenznummer,X, + 2,Nachrichten-Kopfsegment,,UNH,0065,00003,UTILM,,Netzanschluss-,X, + 3,Nachrichten-Kopfsegment,,UNH,0065,,D,,Stammdaten,, + 4,Nachrichten-Kopfsegment,,UNH,0052,00003,D,,Entwurfs-Version,X, + 5,Nachrichten-Kopfsegment,,UNH,0054,00003,11A,,Ausgabe 2011 - A,X, + 6,Nachrichten-Kopfsegment,,UNH,0051,00003,UN,,UN/CEFACT,X, + 7,Nachrichten-Kopfsegment,,UNH,0057,00003,VersionsnummerderzugrundeliegendenBDEW-Nachrichtenbeschreibung,,S1.1a,X, + 8,Beginn der Nachricht,,BGM,,00004,,,,Muss, + 9,Beginn der Nachricht,,BGM,1001,00004,E01,,Anmeldungen,X, + 10,Beginn der Nachricht,,BGM,1004,00004,,,Dokumentennummer,X, + 11,Nachrichtendatum,,DTM,,00005,,,,Muss, + 12,Nachrichtendatum,,DTM,2005,00005,137,,Dokumenten-/Nachrichtendatum/-zeit,X, + 13,Nachrichtendatum,,DTM,2380,00005,,,"Datum oder Uhrzeit oderZeitspanne, Wert",X [931][494],"[494] Das hier genannte Datum muss der Zeitpunkt sein, zu dem das Dokument erstellt wurde, oder ein Zeitpunkt, der davor liegt + [931] Format: ZZZ = +00" + 14,Nachrichtendatum,,DTM,2379,00005,303,,CCYYMMDDHHMMZZZ,X, + 15,MP-ID Absender,SG2,,,,,,,Muss, + 16,MP-ID Absender,SG2,NAD,,00008,,,,Muss, + 17,MP-ID Absender,SG2,NAD,3035,00008,MS,,Dokumenten-/Nachrichtenaussteller bzw. -absender,X, + 18,MP-ID Absender,SG2,NAD,3039,00008,,,MP-ID,X, + 19,MP-ID Absender,SG2,NAD,3055,00008,9,,GS1,X, + 20,MP-ID Absender,SG2,NAD,3055,,293,,"DE, BDEW(Bundesverband derEnergie- und",X, + 21,Ansprechpartner,SG3,,,,,,,Kann, + 22,Ansprechpartner,SG3,CTA,,00009,,,,Muss, + 23,Ansprechpartner,SG3,CTA,3139,00009,IC,,Informationskontakt,X, + 24,Ansprechpartner,SG3,CTA,3412,00009,,,Name vom Ansprechpartner,X, + 25,Kommunikationsverbindu ng,SG3,COM,,00010,,,,Muss, + 26,Kommunikationsverbindu ng,SG3,COM,3148,00010,,,Nummer / Adresse,X (([939][321]) ∨([940][322])) ∧[514],"[321] Wenn im DE3155 in demselben COM der Code EM vorhanden ist + [322] Wenn im DE3155 in demselben COM der Code TE / FX / AJ / AL vorhanden ist + [514] Hinweis: Es darf nur eine Information im DE3148 übermittelt werden + [939] Format: Die Zeichenkette muss die Zeichen @ und . enthalten + [940] Format: Die Zeichenkette muss mit dem Zeichen + beginnen und danach dürfen nur noch Ziffern folgen" + 27,Kommunikationsverbindu ng,SG3,COM,3155,00010,EM,,Elektronische Post,X [1P0..1], + 28,Kommunikationsverbindu ng,SG3,COM,3155,,FX,,Telefax,X [1P0..1], + 29,Kommunikationsverbindu ng,SG3,COM,3155,,TE,,Telefon,X [1P0..1], + 30,Kommunikationsverbindu ng,SG3,COM,3155,,AJ,,weiteres Telefon,X [1P0..1], + 31,Kommunikationsverbindu ng,SG3,COM,3155,,AL,,Handy,X [1P0..1], + 32,MP-ID Empfänger,SG2,,,,,,,Muss, + 33,MP-ID Empfänger,SG2,NAD,,00011,,,,Muss, + 34,MP-ID Empfänger,SG2,NAD,3035,00011,MR,,Nachrichtenempfänger,X, + 35,MP-ID Empfänger,SG2,NAD,3039,00011,,,MP-ID,X [280],[280] Nur MP-ID aus + 36,MP-ID Empfänger,SG2,NAD,3055,00011,9,,GS1,X, + 37,MP-ID Empfänger,SG2,NAD,3055,,293,,"DE, BDEW(Bundesverband derEnergie- undWasserwirtschafte.V.)",X, + 38,Vorgang,SG4,,,,,,,Muss, + 39,Vorgang,SG4,IDE,,00020,,,,Muss, + 40,Vorgang,SG4,IDE,7495,00020,24,,Transaktion,X, + 41,Vorgang,SG4,IDE,7402,00020,,,Vorgangsnummer,X, + 42,Beginn zum,SG4,DTM,,00024,,,,Muss, + 43,Beginn zum,SG4,DTM,2005,00024,92,,DatumVertragsbeginn,X, + 44,Beginn zum,SG4,DTM,2380,00024,,,"Datum oder Uhrzeit oderZeitspanne, Wert",X [UB1], + 45,Beginn zum,SG4,DTM,2379,00024,303,,CCYYMMDDHHMMZZZ,X, + 46,Bilanzierungsbeginn,SG4,DTM,,00029,,,,, + 47,Bilanzierungsbeginn,SG4,DTM,2005,00029,158,,Bilanzierungsbeginn,, + 48,Bilanzierungsbeginn,SG4,DTM,2380,00029,,,"Datum oder Uhrzeit oderZeitspanne, Wert",, + 49,Bilanzierungsbeginn,SG4,DTM,2379,00029,303,,CCYYMMDDHHMMZZZ,, + 50,Lieferbeginndatum in Bearbeitung,SG4,DTM,,00033,,,,,[36] Wenn SG4 STS+E01++ZC5 (Status der Antwort: Ablehnung andere Anmeldung in Bearbeitung) vorhanden + 51,Lieferbeginndatum in Bearbeitung,SG4,DTM,2005,00033,Z07,,Lieferbeginndatumin Bearbeitung,, + 52,Lieferbeginndatum in Bearbeitung,SG4,DTM,2380,00033,,,"Datum oder Uhrzeit oderZeitspanne, Wert",, + 53,Lieferbeginndatum in Bearbeitung,SG4,DTM,2379,00033,303,,CCYYMMDDHHMMZZZ,, + 54,Datum für nächste Bearbeitung,SG4,DTM,,00034,,,,,[36] Wenn SG4 STS+E01++ZC5 (Status der Antwort: Ablehnung andere Anmeldung in Bearbeitung) vorhanden + 55,Datum für nächste Bearbeitung,SG4,DTM,2005,00034,Z08,,Datum für nächsteBearbeitung,, + 56,Datum für nächste Bearbeitung,SG4,DTM,2380,00034,,,"Datum oder Uhrzeit oderZeitspanne, Wert",, + 57,Datum für nächste Bearbeitung,SG4,DTM,2379,00034,303,,CCYYMMDDHHMMZZZ,, + 58,Transaktionsgrund,SG4,STS,,00037,,,,Muss[2061],[2061] Segment bzw. Segmentgruppe ist genau einmal je SG4 IDE (Vorgang) anzugeben + 59,Transaktionsgrund,SG4,STS,9015,00037,7,,Transaktionsgrund,X, + 60,Transaktionsgrund,SG4,STS,9013,00037,E02,,Einzug in Neuanlage,, + 61,Transaktionsgrund,SG4,STS,9013,,E03,,Wechsel,X, + 62,Status der Antwort,SG4,STS,,00039,,,,,[249] Innerhalb eines SG4 IDE müssen alle DE1131 der SG4 STS+E01 den identischen Wert enthalten + 63,Status der Antwort,SG4,STS,9015,00039,E01,,Status der Antwort,, + 64,Status der Antwort,SG4,STS,9013,00039,,,Code des Prüfschritts,, + 65,Status der Antwort,SG4,STS,1131,00039,Codeliste Strom Nr.S_0049Codeliste Strom Nr.S_0050Codeliste Strom Nr.S_0051,,S_0049S_0050S_0051,, + 66,Status der Antwort des dritten Marktbeteiligten,SG4,STS,,00040,,,,,[84] Wenn SG4 STS+E01++Z35 (Status + 67,Status der Antwort des dritten Marktbeteiligten,SG4,STS,9015,00040,Z35,,Status der Antwortdes drittenMarktbeteiligten,, + 68,Status der Antwort des dritten Marktbeteiligten,SG4,STS,9013,00040,,,Code des Prüfschritts,, + 69,Status der Antwort des dritten Marktbeteiligten,SG4,STS,1131,00040,Codeliste Strom Nr.S_0048,,S_0048,, + 70,Netzlokation,SG5,,,,,,,,"[46] Wenn ID für Objekt vergeben wurde + [688] Hinweis: Es sind alle ID der Netzlokationen, welche der im LOC+Z16 angegebenen Marktlokation vorgelagert sind anzugeben" + 71,Netzlokation,SG5,LOC,,00050,,,,, + 72,Netzlokation,SG5,LOC,3227,00050,Z18,,Netzlokation,, + 73,Netzlokation,SG5,LOC,3225,00050,,,ID der Netzlokation,,[960] Format: Netzlokations-ID + 74,Marktlokation,SG5,,,,,,,Muss[2061] ∧[348] ∧[524],"[348] Wenn SG5 LOC+Z21 (Tranche) nicht vorhanden + [524] Hinweis: Bei Geschäftsvorfall 1 und 3: ist die ID der Marktlokation anzugeben + [2061] Segment bzw. Segmentgruppe ist genau einmal je SG4 IDE (Vorgang) anzugeben" + 75,Marktlokation,SG5,LOC,,00051,,,,Muss, + 76,Marktlokation,SG5,LOC,3227,00051,Z16,,Marktlokation,X, + 77,Marktlokation,SG5,LOC,3225,00051,,,ID der Marktlokation,X [950],[950] Format: Marktlokations-ID + 78,Technische Ressource,SG5,,,,,,,,"[46] Wenn ID für Objekt vergeben wurde + [689] Hinweis: Es sind alle ID der Technischen Ressourcen, welche der im LOC+Z16 angegebenen Marktlokation zugehören anzugeben + [694] Hinweis: Wenn in einer Marktlokation eine ID für eine Technischen Ressource vergeben wird, müssen für alle ggf. weitere Technische Ressourcen in der Marktlokation ID vergeben werden. Hintergrund: MSB und LF benötigen einen vollständigen Überblick auf die Art und Nutzung der Technischen Ressourcen in einer Marktlokation für die Plausibilisierung, Ersatzwertbildung, Produktauswahl bzw. Prognose + [698] Hinweis: Für eine erzeugende Marktlokation muss für jede Technische Ressource eine ID der Technischen Ressourcen vergeben werden. Dies ist notwendig um die Nennleistung der Technische Ressource bekannt zu geben, da auf Basis diese Information die POG" + 79,Technische Ressource,SG5,LOC,,00052,,,,, + 80,Technische Ressource,SG5,LOC,3227,00052,Z20,,TechnischeRessource,, + 81,Technische Ressource,SG5,LOC,3225,00052,,,ID der TechnischenRessource,,[922] Format: TR-ID + 82,Steuerbare Ressource,SG5,,,,,,,,"[46] Wenn ID für Objekt vergeben wurde + [690] Hinweis: Es sind alle ID der Steuerbaren Ressourcen, welche der im LOC+Z20 angegebenen Technischen Ressourcen zugeordnet sind anzugeben" + 83,Steuerbare Ressource,SG5,LOC,,00053,,,,, + 84,Steuerbare Ressource,SG5,LOC,3227,00053,Z19,,SteuerbareRessource,, + 85,Steuerbare Ressource,SG5,LOC,3225,00053,,,ID der SteuerbarenRessource,,[961] Format: SR-ID + 86,Tranche,SG5,,,,,,,Muss[2061] ∧[347] ∧[582],"[347] Wenn SG5 LOC+Z16 (Marktlokation) nicht vorhanden + [526] Hinweis: Bei Geschäftsvorfall 2: ID der Marktlokation und ID der Tranche, bei Geschäfts-vorfall 1 und 3: ID der Marktlokation + [582] Hinweis: Bei Geschäftsvorfall 2 ist die ID der Tranche anzugeben + [625] Hinweis: Bei" + 87,Tranche,SG5,LOC,,00054,,,,Muss, + 88,Tranche,SG5,LOC,3227,00054,Z21,,Tranche,X, + 89,Tranche,SG5,LOC,3225,00054,,,ID der Tranche,X [950],[950] Format: Marktlokations-ID + 90,Messlokation,SG5,,,,,,,,"[623] Hinweis: Es sind alle Identifikatoren der Messlokationen anzugeben, die zur Ermittlung der Energiemenge der im Vorgang genannten Marktlokation benötigt werden" + 91,Messlokation,SG5,LOC,,00055,,,,, + 92,Messlokation,SG5,LOC,3227,00055,Z17,,Messlokation,, + 93,Messlokation,SG5,LOC,3225,00055,,,ID der Messlokation,,[951] Format: Zählpunktbezeichnung + 94,Prüfidentifikator,SG6,,,,,,,Muss, + 95,Prüfidentifikator,SG6,RFF,,00057,,,,Muss, + 96,Prüfidentifikator,SG6,RFF,1153,00057,Z13,,Prüfidentifikator,X, + 97,Prüfidentifikator,SG6,RFF,1154,00057,55077,,MPES / Anmeldung,X, + 98,Prüfidentifikator,SG6,RFF,1154,,55078,,MPES / BestätigungAnmeldung,, + 99,Prüfidentifikator,SG6,RFF,1154,,55079,,MPES / BestätigungAnmeldungNeuanlage und,, + 100,Referenz Vorgangsnummer (aus Anfragenachricht),SG6,,,,,,,, + 101,Referenz Vorgangsnummer (aus Anfragenachricht),SG6,RFF,,00058,,,,, + 102,Referenz Vorgangsnummer (aus Anfragenachricht),SG6,RFF,1153,00058,TN,,Transaktions-Referenznummer,, + 103,Referenz Vorgangsnummer (aus Anfragenachricht),SG6,RFF,1154,00058,,,Vorgangsnummer,, + 104,Referenz auf die ID der Marktlokation für Termine der Marktlokation,SG6,,,,,,,Kann [624],"[21] Wenn SG10 CCI+++ZA6 (Prognose auf Basis von Profilen) in dieser SG8 vorhanden + [234] Wenn SG10 CCI+++Z83 (Messtechnische Einordnung der Marktlokation) CAV+Z53 (kME/ mME) vorhanden + [624] Hinweis: Bei Geschäftsvorfall 1" + 105,Referenz auf die ID der Marktlokation für Termine der Marktlokation,SG6,RFF,,00066,,,,Muss [636],[636] Hinweis: Dieses RFF klassifiziert mit einem Code im DE1153 die in derselben Segmentgruppe enthaltenen DTM zu einem Markt- bzw. Messlokation relevanten Inhalt + 106,Referenz auf die ID der Marktlokation für Termine der Marktlokation,SG6,RFF,1153,00066,Z18,,Marktlokation,X, + 107,Referenz auf die ID der Marktlokation für Termine der Marktlokation,SG6,RFF,1154,00066,,,ID der Marktlokation,X [950],[950] Format: Marktlokations-ID + 108,Turnusablesung des MSB,SG6,DTM,,00067,,,,,"[21] Wenn SG10 CCI+++ZA6 (Prognose auf Basis von Profilen) in dieser SG8 vorhanden + [234] Wenn SG10 CCI+++Z83 (Messtechnische Einordnung der Marktlokation) CAV+Z53 (kME/ mME) vorhanden" + 109,Turnusablesung des MSB,SG6,DTM,2005,00067,752,,Turnusablesung,, + 110,Turnusablesung des MSB,SG6,DTM,2380,00067,,,"Datum oder Uhrzeit oderZeitspanne, Wert",, + 111,Turnusablesung des MSB,SG6,DTM,2379,00067,104,,MMWW-MMWW,, + 112,Turnusablesung des MSB,SG6,DTM,2379,,106,,MMDD,, + 113,Referenz auf die Lokationsbündelstruktur,SG8,,,,,,,,"[309] Wenn DTM+137 (Nachrichtendatum) im DE2380 ≥ 202409302200?+00 + [513] Hinweis: Bei Anwendung dieser Segmentgruppe vor dem 01.10.2024 sind die Codes in diesem Segment noch nicht gültig. Somit wird der Geschäftsvorfall mit einer Verarbeitbarkeitsfehle rmeldung mit Fehlercode Z39 (Code nicht aus erlaubtem Wertebereich“) abgelehnt werden + [2061] Segment bzw. Segmentgruppe ist genau einmal je SG4 IDE (Vorgang) anzugeben" + 114,Referenz auf die Lokationsbündelstruktur,SG8,SEQ,,00071,,,,, + 115,Referenz auf die Lokationsbündelstruktur,SG8,SEQ,1229,00071,Z78,,Referenz auf die,, + 116,Referenz auf die Lokationsbündelstruktur,SG8,RFF,,00072,,,,, + 117,Referenz auf die Lokationsbündelstruktur,SG8,RFF,1153,00072,Z31,,Lokationsbündelstruktur,, + 118,Referenz auf die Lokationsbündelstruktur,SG8,RFF,1153,,Z39,,KeinestandardisierteLokationsbündelstruktur vorhanden,, + 119,Referenz auf die Lokationsbündelstruktur,SG8,RFF,1154,00072,,,ID derLokationsbündelstruktur,,"[335] Wenn im SG8 SEQ+Z78 RFF+Z31 ""Referenz auf die Lokationsbündelstrukt ur"" im DE1153 der Code Z31 ""Lokationsbündelstruk tur"" vorhanden ist" + 120,Referenz auf die Lokationsbündelstruktur,SG8,RFF,1156,00072,,,Fortlaufende Nummer einesLokationsbündels imGeschäftsvorfall,,"[32] Wenn mehr als ein SG8 SEQ+Z78 (Referenz auf die Lokationsbündelstrukt ur) vorhanden + [914] Format: Möglicher Wert: > 0 + [937] Format: keine Nachkommastelle" + 121,Zuordnung Lokation zum Objektcode des Lokationsbündels,SG8,,,,,,,,"[335] Wenn im SG8 SEQ+Z78 RFF+Z31 ""Referenz auf die Lokationsbündelstrukt ur"" im DE1153 der Code Z31 ""Lokationsbündelstruk tur"" vorhanden ist + [513] Hinweis: Bei Anwendung dieser Segmentgruppe vor dem 01.10.2024 sind die Codes in diesem Segment noch nicht" + 122,Zuordnung Lokation zum Objektcode des Lokationsbündels,SG8,SEQ,,00073,,,,, + 123,Zuordnung Lokation zum Objektcode des Lokationsbündels,SG8,SEQ,1229,00073,Z58,,Zuordnung Lokationzum Objektcode desLokationsbündels,, + 124,Referenz auf die ID der Netzlokation / Marktlokation / Messlokation / Technischen Ressource,SG8,RFF,,00074,,,,, + 125,Referenz auf die ID der Netzlokation / Marktlokation / Messlokation / Technischen Ressource,SG8,RFF,1153,00074,Z32,,Netzlokation,, + 126,Referenz auf die ID der Netzlokation / Marktlokation / Messlokation / Technischen Ressource,SG8,RFF,1153,,Z18,,Marktlokation,, + 127,Referenz auf die ID der Netzlokation / Marktlokation / Messlokation / Technischen Ressource,SG8,RFF,1153,,Z19,,Messlokation,, + 128,Referenz auf die ID der Netzlokation / Marktlokation / Messlokation / Technischen Ressource,SG8,RFF,1153,,Z37,,TechnischeRessource,, + 129,Referenz auf die ID der Netzlokation / Marktlokation / Messlokation / Technischen Ressource,SG8,RFF,1154,00074,,,ID einer Lokation,,"[450] Wenn in demselben RFF der Code Z32 (Netzlokation) im DE1153 vorhanden + [451] Wenn in demselben RFF der Code Z18 (Marktlokation) im DE1153 vorhanden + [452] Wenn in demselben RFF der" + 130,Referenz auf den Objektcode in der Lokationsbündelstruktur,SG8,RFF,,00075,,,,,[2313] Je SG8 SEQ+Z58 (Zuordnung Lokation zum Objektcode des Lokationsbündels) genau einmal anzugeben + 131,Referenz auf den Objektcode in der Lokationsbündelstruktur,SG8,RFF,1153,00075,Z33,,Objektcode derLokation in derLokationsbündelstruktur,, + 132,Referenz auf den Objektcode in der Lokationsbündelstruktur,SG8,RFF,1154,00075,,,Objekt Code,, + 133,Referenz auf den Objektcode in der Lokationsbündelstruktur,SG8,RFF,1156,00075,,,Fortlaufende Nummer einesLokationsbündels imGeschäftsvorfall,,"[32] Wenn mehr als ein SG8 SEQ+Z78 (Referenz auf die Lokationsbündelstrukt ur) vorhanden + [914] Format: Möglicher Wert: > 0 + [937] Format: keine Nachkommastelle" + 134,Referenz auf die ID der vorgelagerten Netzlokation / Messlokation ,SG8,RFF,,00076,,,,,[290] Wenn der Objektcode im RFF+Z33 (Referenz auf den Objektcode in der Lokationsbündelstrukt ur) im DE1154 derselben SG8 SEQ+Z58 (Zuordnung Lokation zum Objektcode des Lokationsbündels) in einem weiteren SG8 SEQ+Z58 vorhanden ist + 135,Referenz auf die ID der vorgelagerten Netzlokation / Messlokation ,SG8,RFF,1153,00076,Z34,,vorgelagerteMesslokation,, + 136,Referenz auf die ID der vorgelagerten Netzlokation / Messlokation ,SG8,RFF,1153,,Z35,,vorgelagerteNetzlokation,, + 137,Referenz auf die ID der vorgelagerten Netzlokation / Messlokation ,SG8,RFF,1154,00076,,,ID einer Lokation,,"[471] Wenn in demselben RFF der Code Z35 (vorgelagerte Netzlokation) im DE1153 vorhanden + [472] Wenn in demselben RFF der Code Z34 (vorgelagerte Messlokation) im DE1153 vorhanden + [951] Format: Zählpunktbezeichnung + [960] Format: Netzlokations-ID" + 138,Referenz auf die der Technischen Ressource zugeordneten Marktlokation ,SG8,RFF,,00077,,,,,[290] Wenn der Objektcode im RFF+Z33 (Referenz auf den Objektcode in der Lokationsbündelstrukt ur) im DE1154 derselben SG8 + 139,Referenz auf die der Technischen Ressource zugeordneten Marktlokation ,SG8,RFF,1153,00077,Z16,,zugeordneteMarktlokation,, + 140,Referenz auf die der Technischen Ressource zugeordneten Marktlokation ,SG8,RFF,1154,00077,,,ID der Marktlokation,,[950] Format: Marktlokations-ID + 141,Daten der Netzlokation,SG8,,,,,,,,"[294] Wenn SG5 LOC+Z18 (Netzlokation) vorhanden + [2356] Je SG5 LOC+Z18 (Netzlokation) ist genau einmal die Segmentgruppe anzugeben" + 142,Daten der Netzlokation,SG8,SEQ,,00078,,,,, + 143,Daten der Netzlokation,SG8,SEQ,1229,00078,Z51,,Daten derNetzlokation,, + 144,Referenz auf die ID der Netzlokation,SG8,RFF,,00079,,,,, + 145,Referenz auf die ID der Netzlokation,SG8,RFF,1153,00079,Z32,,Netzlokation,, + 146,Referenz auf die ID der Netzlokation,SG8,RFF,1154,00079,,,ID der Netzlokation,,[960] Format: Netzlokations-ID + 147,Steuerkanal,SG10,,,,,,,, + 148,Steuerkanal,SG10,CCI,,00080,,,,, + 149,Steuerkanal,SG10,CCI,7059,00080,Z49,,Steuerkanal,, + 150,Steuerkanal,SG10,CCI,7037,00080,ZF2,,Kein Steuerkanalvorhanden,, + 151,Steuerkanal,SG10,CCI,7037,,ZF3,,Steuerkanal,, + 152,Zugeordnete Marktpartner,SG10,,,,,,,, + 153,Zugeordnete Marktpartner,SG10,CCI,,00081,,,,, + 154,Zugeordnete Marktpartner,SG10,CCI,7037,00081,ZB3,,ZugeordneterMarktpartner,, + 155,Messstellenbetreiber,SG10,CAV,,00082,,,,, + 156,Messstellenbetreiber,SG10,CAV,7111,00082,Z91,,MSB,, + 157,Messstellenbetreiber,SG10,CAV,1131,00082,,,MP-ID,, + 158,Messstellenbetreiber,SG10,CAV,7110,00082,Z39,,GrundzuständigerMessstellenbetreiber,, + 159,Messstellenbetreiber,SG10,CAV,7110,,Z40,,WettbewerblicherMessstellenbetreiber,, + 160,Messstellenbetreiber,SG10,CAV,7110,,Z41,,Auffangmessstellenbetreiber,, + 161,Produkt-Daten der Netzlokation,SG8,,,,,,,,"[166] Wenn vorhanden + [294] Wenn SG5 LOC+Z18 (Netzlokation) vorhanden" + 162,Produkt-Daten der Netzlokation,SG8,SEQ,,00095,,,,, + 163,Produkt-Daten der Netzlokation,SG8,SEQ,1229,00095,Z60,,Produkt-Daten derNetzlokation,, + 164,Referenz auf die ID der Netzlokation,SG8,RFF,,00096,,,,, + 165,Referenz auf die ID der Netzlokation,SG8,RFF,1153,00096,Z32,,Netzlokation,, + 166,Referenz auf die ID der Netzlokation,SG8,RFF,1154,00096,,,ID einer Netzlokation,,[960] Format: Netzlokations-ID + 167,Produkt-Daten der Netzlokation,SG8,PIA,,00097,,,,, + 168,Produkt-Daten der Netzlokation,SG8,PIA,4347,00097,5,,Produktidentifikation,, + 169,Produkt-Daten der Netzlokation,SG8,PIA,7140,00097,,,Konfigurationsprodukt-,,[412] Es sind + 170,Produkt-Daten der Netzlokation,SG8,PIA,7143,00097,Z12,,Konfigurationsprodukt,, + 171,Zugeordnete Leistungskurvendefinition,SG10,,,,,,,,[190] Wenn in derselben SG8 SEQ+Z60 (Produkt- Daten der Netzlokation) PIA+5+999100000072 1:Z12 vorhanden + 172,Zugeordnete Leistungskurvendefinition,SG10,CCI,,00099,,,,, + 173,Zugeordnete Leistungskurvendefinition,SG10,CCI,7059,00099,Z53,,Code derLeistungskurvendefinition,, + 174,Zugeordnete Leistungskurvendefinition,SG10,CCI,7037,00099,,,Code derLeistungskurvendefinition,, + 175,Auftraggebender Marktpartner,SG10,,,,,,,, + 176,Auftraggebender Marktpartner,SG10,CCI,,00100,,,,, + 177,Auftraggebender Marktpartner,SG10,CCI,7037,00100,ZB3,,ZugeordneterMarktpartner,, + 178,Auftraggebender Marktpartner,SG10,CAV,,00101,,,,, + 179,Auftraggebender Marktpartner,SG10,CAV,7111,00101,Z88,,NB,, + 180,Auftraggebender Marktpartner,SG10,CAV,7111,,Z89,,LF,, + 181,Auftraggebender Marktpartner,SG10,CAV,1131,00101,,,MP-ID,, + 182,Produkt-Daten für Marktrolle relevant,SG10,,,,,,,, + 183,Produkt-Daten für Marktrolle relevant,SG10,CCI,,00102,,,,, + 184,Produkt-Daten für Marktrolle relevant,SG10,CCI,7037,00102,ZA7,,LF,, + 185,Daten der Marktlokation,SG8,,,,,,,Muss[2061],[2061] Segment bzw. Segmentgruppe ist genau einmal je SG4 IDE (Vorgang) anzugeben + 186,Daten der Marktlokation,SG8,SEQ,,00103,,,,Muss, + 187,Daten der Marktlokation,SG8,SEQ,1229,00103,Z01,,Daten derMarktlokation,X, + 188,Referenz auf die ID der Marktlokation,SG8,RFF,,00104,,,,Muss [439]∧ [627],"[439] Wenn in dem SG8 SEQ+Z15 (Daten der Tranche) das RFF+Z20 (Referenz auf die ID der Tranche) nicht vorhanden + [627] Hinweis: Bei Geschäftsvorfall 1 und 3" + 189,Referenz auf die ID der Marktlokation,SG8,RFF,1153,00104,Z18,,Marktlokation,X, + 190,Referenz auf die ID der Marktlokation,SG8,RFF,1154,00104,,,ID der Marktlokation,X [950],[950] Format: Marktlokations-ID + 191,Arbeit / Leistung für tagesparameterabhängige Marktlokation,SG9,,,,,,,,"[101] Wenn SG10 CCI+++ZA6 (Prognosegrundlage der Marktlokation: Prognose auf Basis von Profilen) CAV+E14/ Z36 (TLP/ TEP/ TEP mit Ref. messung) in dieser SG8 vorhanden + [300] Wenn SG8 SEQ+Z15 (Daten der Tranche) nicht vorhanden" + 192,Arbeit / Leistung für tagesparameterabhängige Marktlokation,SG9,QTY,,00105,,,,, + 193,Arbeit / Leistung für tagesparameterabhängige Marktlokation,SG9,QTY,6063,00105,Z10,,Leistung derMarktlokation,, + 194,Arbeit / Leistung für tagesparameterabhängige Marktlokation,SG9,QTY,6063,,265,,VeranschlagteJahresmengeGesamt/,,[102] Wenn SG10 CCI+++ZA6 (Prognosegrundlage der Marktlokation: Prognose auf Basis + 195,Arbeit / Leistung für tagesparameterabhängige Marktlokation,SG9,QTY,6060,00105,,,Menge,,[902] Format: Möglicher Wert: ≥ 0 + 196,Arbeit / Leistung für tagesparameterabhängige Marktlokation,SG9,QTY,6411,00105,Z16,,kWh/K (Kilowatt-Stunde/Kelvin),, + 197,Arbeit / Leistung für tagesparameterabhängige Marktlokation,SG9,QTY,6411,,KWH,,Kilowattstunde,, + 198,Arbeit / Leistung für tagesparameterabhängige Marktlokation,SG9,QTY,6411,,KWT,,Kilowatt,,"[103] Wenn SG9 QTY+265 (Arbeit / Leistung für tagesparameterabhän gig e Marktlokation: Veranschlagte Jahresmenge Gesamt) in dieser SG8 vorhanden + [104] Wenn SG9 QTY+Z08 (Arbeit / Leistung für tagesparameterabhän gige Marktlokation: angepasste elektrische Arbeit nach Anhang D) in dieser SG8 vorhanden + [105] Wenn SG9 QTY+Z10 (Arbeit / Leistung für tagesparameterabhän gige Marktlokation: Leistung der Marktlokation) in dieser SG8 vorhanden" + 199,Veranschlagte Jahresmenge gesamt,SG9,,,,,,,Kann,[106] Wenn in dieser SG8 SEQ+Z01 SG10 CCI+++ZA6 + 200,Veranschlagte Jahresmenge gesamt,SG9,QTY,,00106,,,,Muss, + 201,Veranschlagte Jahresmenge gesamt,SG9,QTY,6063,00106,31,,VeranschlagteJahresmengeGesamt,X, + 202,Veranschlagte Jahresmenge gesamt,SG9,QTY,6060,00106,,,Mengenangabe,X [902] ∧[937],"[902] Format: Möglicher Wert: ≥ 0 + [937] Format: keine Nachkommastelle" + 203,Veranschlagte Jahresmenge gesamt,SG9,QTY,6411,00106,KWH,,Kilowattstunde,X, + 204,Lieferrichtung,SG10,,,,,,,Muss, + 205,Lieferrichtung,SG10,CCI,,00110,,,,Muss, + 206,Lieferrichtung,SG10,CCI,7059,00110,Z30,,Lieferrichtung,X, + 207,Lieferrichtung,SG10,CCI,7037,00110,Z06,,Erzeugung,X, + 208,Zugeordnete Marktpartner,SG10,,,,,,,, + 209,Zugeordnete Marktpartner,SG10,CCI,,00111,,,,, + 210,Zugeordnete Marktpartner,SG10,CCI,7037,00111,ZB3,,ZugeordneterMarktpartner,, + 211,Übertragungsnetzbetreib er,SG10,CAV,,00114,,,,, + 212,Übertragungsnetzbetreib er,SG10,CAV,7111,00114,Z90,,ÜNB,, + 213,Übertragungsnetzbetreib er,SG10,CAV,1131,00114,,,MP-ID,, + 214,Messstellenbetreiber,SG10,CAV,,00115,,,,, + 215,Messstellenbetreiber,SG10,CAV,7111,00115,Z91,,MSB,, + 216,Messstellenbetreiber,SG10,CAV,1131,00115,,,MP-ID,, + 217,Messstellenbetreiber,SG10,CAV,7110,00115,Z19,,Auf vertraglicherGrundlagegegenüberAnschlussnutzer /,, + 218,Messstellenbetreiber,SG10,CAV,7110,00115,Z39,,GrundzuständigerMessstellenbetreiber,, + 219,Messstellenbetreiber,SG10,CAV,7110,,Z40,,WettbewerblicherMessstellenbetreiber,, + 220,Messstellenbetreiber,SG10,CAV,7110,,Z41,,Auffangmessstellenbetreiber,, + 221,Regelzone,SG10,,,,,,,, + 222,Regelzone,SG10,CCI,,00116,,,,, + 223,Regelzone,SG10,CCI,7059,00116,Z18,,Regelzone,, + 224,Regelzone,SG10,CCI,7037,00116,,,Regelzone,, + 225,Bilanzkreis,SG10,,,,,,,Muss[2061] ∧[111] ∧[624],"[111] Wenn CCI+Z19 (Bilanzkreis) in SG8 SEQ+Z15 (Daten der Tranche) nicht vorhanden + [300] Wenn SG8 SEQ+Z15 (Daten der Tranche) nicht vorhanden + [624] Hinweis: Bei Geschäftsvorfall 1 + [2061] Segment bzw. Segmentgruppe ist genau einmal je SG4 IDE (Vorgang) anzugeben" + 226,Bilanzkreis,SG10,CCI,,00117,,,,Muss, + 227,Bilanzkreis,SG10,CCI,7059,00117,Z19,,Bilanzkreis,X, + 228,Bilanzkreis,SG10,CCI,7037,00117,,,Bilanzkreis,X, + 229,Bilanzierungsgebiet,SG10,,,,,,,, + 230,Bilanzierungsgebiet,SG10,CCI,,00118,,,,, + 231,Bilanzierungsgebiet,SG10,CCI,7059,00118,Z20,,Bilanzierungsgebiet,, + 232,Bilanzierungsgebiet,SG10,CCI,7037,00118,,,Bilanzierungsgebiet,, + 233,Zeitreihentyp,SG10,,,,,,,,[2061] Segment bzw. + 234,Zeitreihentyp,SG10,CCI,,00121,,,,, + 235,Zeitreihentyp,SG10,CCI,7059,00121,15,,Struktur,, + 236,Zeitreihentyp,SG10,CCI,7037,00121,Z21,,Summenzeitreihentyp,, + 237,Zeitreihentyp,SG10,CAV,,00122,,,,, + 238,Zeitreihentyp,SG10,CAV,7111,00122,,,Code des Zeitreihentyps,, + 239,Spannungsebene der Marktlokation,SG10,,,,,,,, + 240,Spannungsebene der Marktlokation,SG10,CCI,,00123,,,,, + 241,Spannungsebene der Marktlokation,SG10,CCI,7037,00123,E03,,Spannungsebeneder Marktlokation,, + 242,Spannungsebene der Marktlokation,SG10,CAV,,00124,,,,, + 243,Spannungsebene der Marktlokation,SG10,CAV,7111,00124,E03,,Höchstspannung,, + 244,Spannungsebene der Marktlokation,SG10,CAV,7111,,E04,,Hochspannung,, + 245,Spannungsebene der Marktlokation,SG10,CAV,7111,,E05,,Mittelspannung,, + 246,Spannungsebene der Marktlokation,SG10,CAV,7111,,E06,,Niederspannung,, + 247,Umspannung der Marktlokation,SG10,CAV,,00125,,,,,[166] Wenn vorhanden + 248,Umspannung der Marktlokation,SG10,CAV,7111,00125,E07,,Hös/HSUmspannung,, + 249,Umspannung der Marktlokation,SG10,CAV,7111,,E08,,HS/MS Umspannung,, + 250,Umspannung der Marktlokation,SG10,CAV,7111,,E09,,MS/NS Umspannung,,"[114] Wenn das SG10 CCI+E03 (Spannungsebene der Marktlokation) CAV E06 (Niederspannung) in dieser SG vorhanden + [115] Wenn das SG10 CCI+E03 (Spannungsebene der Marktlokation) CAV E05 (Mittelspannung) in dieser SG vorhanden " + 251,Messtechnische Einordnung der Marktlokation,SG10,,,,,,,, + 252,Messtechnische Einordnung der Marktlokation,SG10,CCI,,00126,,,,, + 253,Messtechnische Einordnung der Marktlokation,SG10,CCI,7037,00126,Z83,,MesstechnischeEinordnung derMarktlokation,, + 254,Messtechnische Einordnung der Marktlokation,SG10,CAV,,00127,,,,, + 255,Messtechnische Einordnung der Marktlokation,SG10,CAV,7111,00127,Z52,,iMS,, + 256,Messtechnische Einordnung der Marktlokation,SG10,CAV,7111,,Z53,,kME / mME,, + 257,Aggregationsverantwortu ng in MaBiS,SG10,,,,,,,, + 258,Aggregationsverantwortu ng in MaBiS,SG10,CCI,,00128,,,,, + 259,Aggregationsverantwortu ng in MaBiS,SG10,CCI,7059,00128,6,,Verantwortlicher,, + 260,Aggregationsverantwortu ng in MaBiS,SG10,CCI,7037,00128,ZA8,,NB,, + 261,Aggregationsverantwortu ng in MaBiS,SG10,CCI,7037,,ZA9,,ÜNB,, + 262,Prognosegrundlage der Marktlokation,SG10,,,,,,,, + 263,Prognosegrundlage der Marktlokation,SG10,CCI,,00130,,,,, + 264,Prognosegrundlage der Marktlokation,SG10,CCI,7037,00130,ZC0,,Prognose auf Basis,, + 265,Prognosegrundlage der Marktlokation,SG10,CCI,7037,,ZA6,,Prognose auf Basisvon Profilen,, + 266,Details der Prognosegrundlage,SG10,CAV,,00131,,,,,[21] Wenn SG10 CCI+++ZA6 (Prognose auf Basis von Profilen) in dieser SG8 vorhanden + 267,Details der Prognosegrundlage,SG10,CAV,7111,00131,E02,,SLP/SEP,, + 268,Details der Prognosegrundlage,SG10,CAV,7111,,E14,,TLP/TEP,, + 269,Details der Prognosegrundlage,SG10,CAV,7111,,Z36,,TEP mitReferenzmessung,, + 270,Art der erzeugenden Marktlokation,SG10,,,,,,,,[118] Wenn SG4 STS+E01++Z35 (Status der Antwort: Ablehnung der Abmeldeanfrage) nicht vorhanden + 271,Art der erzeugenden Marktlokation,SG10,CCI,,00137,,,,, + 272,Art der erzeugenden Marktlokation,SG10,CCI,7037,00137,Z34,,Art der erzeugendenMarktlokation,, + 273,Art der erzeugenden Marktlokation ,SG10,CAV,,00138,,,,, + 274,Art der erzeugenden Marktlokation ,SG10,CAV,7111,00138,Z33,,EEG-Marktlokationohne DV-Pflicht,, + 275,Art der erzeugenden Marktlokation ,SG10,CAV,7111,,Z34,,KWKG-Marktlokation ohneDV-Pflicht,, + 276,Art der erzeugenden Marktlokation ,SG10,CAV,7111,,Z35,,sonstigeMarktlokation,, + 277,Art der erzeugenden Marktlokation ,SG10,CAV,7111,,Z37,,EEG-Marktlokationmit DV-Pflicht,, + 278,Art der erzeugenden Marktlokation ,SG10,CAV,7111,,Z46,,KWKG-Marktlokation mitDV-Pflicht,, + 279,Empfänger der Vergütung zur Einspeisung,SG10,,,,,,,Muss [55],[55] Wenn SG10 CCI+Z22++Z91 (Status der erzeugenden Marktlokation: Veräußerungsform Geförderte Direktvermarktung bzw. Marktprämie) vorhanden + 280,Empfänger der Vergütung zur Einspeisung,SG10,CCI,,00146,,,,Muss, + 281,Empfänger der Vergütung zur Einspeisung,SG10,CCI,7037,00146,Z89,,Empfänger derVergütung,X, + 282,Empfänger der Vergütung zur Einspeisung,SG10,CAV,,00147,,,,Muss, + 283,Empfänger der Vergütung zur Einspeisung,SG10,CAV,7110,00147,Z10,,Kunde,X, + 284,Empfänger der Vergütung zur Einspeisung,SG10,CAV,7110,,Z11,,Lieferant,X, + 285,Status der erzeugenden Marktlokation,SG10,,,,,,,Muss, + 286,Status der erzeugenden Marktlokation,SG10,CCI,,00148,,,,Muss, + 287,Status der erzeugenden Marktlokation,SG10,CCI,7059,00148,Z22,,GesetzlicheKategorie,X, + 288,Status der erzeugenden Marktlokation,SG10,CCI,7037,00148,Z90,,EEG-Veräußerungsform:Ausfallvergütung,X [695], + 289,Status der erzeugenden Marktlokation,SG10,CCI,7037,,Z91,,EEG-Veräußerungsform:Marktprämie,X [696], + 290,Status der erzeugenden Marktlokation,SG10,CCI,7037,,Z92,,EEG-Veräußerungsform:Sonstiges,X [696], + 291,Status der erzeugenden Marktlokation,SG10,CCI,7037,,Z94,,KWKG-Vergütung,X [695],"[695] Hinweis: Verwendung, wenn Rolle LF einem Unternehmen NB zugeordnet ist + [696] Hinweis: Verwendung, nur wenn die Rolle LF nicht einem Unternehmen NB zugeordnet ist" + 292,Land der Förderung,SG10,,,,,,,Muss[240],[240] Wenn SG8 SEQ+Z01 (Daten der Marktlokation) CCI+Z22++Z91 (Status der erzeugenden Marktlokation: Veräußerungsform Geförderte Direktvermarktung bzw. Marktprämie) vorhanden + 293,Land der Förderung,SG10,CCI,,00149,,,,Muss, + 294,Land der Förderung,SG10,CCI,7059,00149,Z23,,Land der Förderung,X, + 295,Land der Förderung,SG10,CCI,7037,00149,,,Land der Förderung,X, + 296,Land der Förderung,SG10,CCI,1131,00149,LAND,,EDI@EnergyCodeliste dereuropäischenLändercodes,X, + 297,Land der Förderung,SG10,CCI,3055,00149,293,,"DE, BDEW(Bundesverband derEnergie- und",X, + 298,Status der Fernsteuerbarkeit,SG10,,,,,,,Muss [55],[55] Wenn SG10 CCI+Z22++Z91 (Status der erzeugenden Marktlokation: Veräußerungsform Geförderte Direktvermarktung bzw. Marktprämie) vorhanden + 299,Status der Fernsteuerbarkeit,SG10,CCI,,00150,,,,Muss, + 300,Status der Fernsteuerbarkeit,SG10,CCI,7059,00150,Z24,,Status derFernsteuerbarkeit,X, + 301,Status der Fernsteuerbarkeit,SG10,CCI,7037,00150,Z96,,Marktlokation isttechnisch nichtfernsteuerbar,X, + 302,Status der Fernsteuerbarkeit,SG10,CCI,7037,,Z97,,Marktlokation isttechnischfernsteuerbar,X, + 303,Status der Fernsteuerbarkeit,SG10,CCI,7037,,Z98,,Marktlokation istdurch denLieferantenfernsteuerbar,X, + 304,OBIS-Daten der Marktlokation,SG8,,,,,,,,[300] Wenn SG8 SEQ+Z15 (Daten der Tranche) nicht vorhanden + 305,OBIS-Daten der Marktlokation,SG8,SEQ,,00198,,,,, + 306,OBIS-Daten der Marktlokation,SG8,SEQ,1229,00198,Z02,,OBIS-Daten derMarktlokation,, + 307,Referenz auf die ID der Marktlokation,SG8,RFF,,00199,,,,, + 308,Referenz auf die ID der Marktlokation,SG8,RFF,1153,00199,Z18,,Marktlokation,, + 309,Referenz auf die ID der Marktlokation,SG8,RFF,1154,00199,,,ID einer Marktlokation,,[950] Format: Marktlokations-ID + 310,OBIS-Kennzahl der Marktlokation,SG8,PIA,,00200,,,,, + 311,OBIS-Kennzahl der Marktlokation,SG8,PIA,4347,00200,5,,Produktidentifikatio,, + 312,OBIS-Kennzahl der Marktlokation,SG8,PIA,7140,00200,,,OBIS-Kennzahl derMarktlokation,,"[314] Es sind alle OBIS-Kennzahlen gem. EDI@Energy Codeliste der OBIS-Kennzahlen und Medien für den deutschen Energiemarkt Kap. 3 anzugeben, welche an der Marktlokation erforderlich sind. Der Mindestumfang der OBIS-Kennzahlen ergibt sich aus den genannten Messprodukt-Codes dem Kap. 5.1 des Dokumentes ""Codeliste der Konfigurationen""" + 313,OBIS-Kennzahl der Marktlokation,SG8,PIA,7143,00200,SRW,,OBIS-Kennzahl,, + 314,Wertegranularität,SG10,,,,,,,,[288] Wenn in derselben SG8 SEQ+Z02 (OBIS-Daten der Marktlokation) das PIA+5+1-b?:2.9.e vorhanden + 315,Wertegranularität,SG10,CCI,,00201,,,,, + 316,Wertegranularität,SG10,CCI,7037,00201,ZE4,,Wertegranularität,, + 317,Wertegranularität,SG10,CAV,,00202,,,,, + 318,Wertegranularität,SG10,CAV,7111,00202,ZD9,,Jährlich,, + 319,Wertegranularität,SG10,CAV,7111,,ZE8,,Halbjährlich,, + 320,Wertegranularität,SG10,CAV,7111,,ZE9,,Quartalsweise,, + 321,Wertegranularität,SG10,CAV,7111,,ZB7,,Monatlich,, + 322,OBIS Daten für Lieferant relevant,SG10,,,,,,,, + 323,OBIS Daten für Lieferant relevant,SG10,CCI,,00207,,,,, + 324,OBIS Daten für Lieferant relevant,SG10,CCI,7037,00207,ZA7,,LF,, + 325,Verwendungszweck der Werte,SG10,CAV,,00208,,,,, + 326,Verwendungszweck der Werte,SG10,CAV,7111,00208,Z85,,Bilanzkreisabrechnu,, + 327,Produkt-Daten der Marktlokation,SG8,,,,,,,,[166] Wenn vorhanden + 328,Produkt-Daten der Marktlokation,SG8,SEQ,,00211,,,,, + 329,Produkt-Daten der Marktlokation,SG8,SEQ,1229,00211,Z59,,Produkt-Daten derMarktlokation,, + 330,Referenz auf die ID der Marktlokation,SG8,RFF,,00212,,,,, + 331,Referenz auf die ID der Marktlokation,SG8,RFF,1153,00212,Z18,,Marktlokation,, + 332,Referenz auf die ID der Marktlokation,SG8,RFF,1154,00212,,,ID einer Marktlokation,,[950] Format: Marktlokations-ID + 333,Produkt-Daten der Marktlokation,SG8,PIA,,00213,,,,, + 334,Produkt-Daten der Marktlokation,SG8,PIA,4347,00213,5,,Produktidentifikation,, + 335,Produkt-Daten der Marktlokation,SG8,PIA,7140,00213,,,Produkt-/Leistungsnummer,, + 336,Produkt-Daten der Marktlokation,SG8,PIA,7143,00213,Z12,,Konfigurationsprodukt,, + 337,Zugeordnete Definition,SG10,,,,,,,, + 338,Zugeordnete Definition,SG10,CCI,,00214,,,,, + 339,Zugeordnete Definition,SG10,CCI,7059,00214,Z53,,Code derLeistungskurvendefinition,, + 340,Zugeordnete Definition,SG10,CCI,7037,00214,,,Code der Definition,, + 341,Produkt-Daten für Marktrolle relevant,SG10,,,,,,,, + 342,Produkt-Daten für Marktrolle relevant,SG10,CCI,,00215,,,,, + 343,Produkt-Daten für Marktrolle relevant,SG10,CCI,7037,00215,ZA7,,LF,, + 344,Produkt-Daten der Marktlokation des NB,SG8,,,,,,,,[255] Wenn Marktlokation am Redispatch 2.0 teilnimmt + 345,Produkt-Daten der Marktlokation des NB,SG8,SEQ,,00227,,,,, + 346,Produkt-Daten der Marktlokation des NB,SG8,SEQ,1229,00227,Z40,,Produkt-Daten derMarktlokation desNB,, + 347,Produktidentifikation der Marktlokation,SG8,PIA,,00228,,,,, + 348,Produktidentifikation der Marktlokation,SG8,PIA,4347,00228,5,,Produktidentifikation,, + 349,Produktidentifikation der Marktlokation,SG8,PIA,7140,00228,AUA,,Ausfallarbeit,, + 350,Produktidentifikation der Marktlokation,SG8,PIA,7143,00228,Z08,,Medium,, + 351,Daten der Tranche,SG8,,,,,,,Muss,[2307] Für jede ID im SG5 LOC+Z21 (Tranche) DE3225 genau einmal anzugeben + 352,Daten der Tranche,SG8,SEQ,,00238,,,,Muss, + 353,Daten der Tranche,SG8,SEQ,1229,00238,Z15,,Daten der Tranche,X, + 354,Referenz auf die ID der Tranche,SG8,RFF,,00239,,,,Muss [440]∧ [626],"[440] Wenn SG8 SEQ+Z01 (Daten der Marktlokation) RFF+Z18 (Referenz auf die ID der Marktlokation) nicht vorhanden + [626] Hinweis: Bei Geschäftsvorfall 2" + 355,Referenz auf die ID der Tranche,SG8,RFF,1153,00239,Z20,,Tranche,X, + 356,Referenz auf die ID der Tranche,SG8,RFF,1154,00239,,,ID der Tranche,X [950],[950] Format: Marktlokations-ID + 357,Prozentualer Anteil der Tranche an der erzeugenden Marktlokation,SG9,,,,,,,Muss[124] ∧[384] ∧,[124] Wenn in derselben SG8 SEQ+Z15 (Daten der + 358,Prozentualer Anteil der Tranche an der erzeugenden Marktlokation,SG9,QTY,,00242,,,,Muss, + 359,Prozentualer Anteil der Tranche an der erzeugenden Marktlokation,SG9,QTY,6063,00242,11,,Aufteilungsmenge,X, + 360,Prozentualer Anteil der Tranche an der erzeugenden Marktlokation,SG9,QTY,6060,00242,,,Mengenangabe in %,X [914] ∧[930] ∧([958] [522]⊻ [955][523]),"[118] Wenn SG4 STS+E01++Z35 (Status der Antwort: Ablehnung der Abmeldeanfrage) nicht vorhanden + [196] Wenn SG4 STS+E01++Z35 (Status der Antwort: Ablehnung der Abmeldeanfrage) vorhanden + [520] Hinweis: Bei Geschäftsvorfall 1 100% + [521] Hinweis: Bei Geschäftsvorfall 2 100% + [522] Hinweis: Bei Geschäftsvorfall 2 prozentualer Anteil der Tranche von der Marktlokation + [523] Hinweis: Bei Geschäftsvorfall 3 prozentualer Anteil der Tranche von der Marktlokation " + 361,Prozentualer Anteil der Tranche an der erzeugenden Marktlokation,SG9,QTY,6411,00242,P1,,Prozent,X, + 362,Bilanzkreis,SG10,,,,,,,Muss[186] ∧[625],"[186] Wenn SG8 SEQ+Z01 (Daten der Marktlokation) SG10 CCI+Z19 (Bilanzkreis) nicht vorhanden + [625] Hinweis: Bei Geschäftsvorfall 2 und 3" + 363,Bilanzkreis,SG10,CCI,,00245,,,,Muss, + 364,Bilanzkreis,SG10,CCI,7059,00245,Z19,,Bilanzkreis,X, + 365,Bilanzkreis,SG10,CCI,7037,00245,,,Bilanzkreis,X, + 366,Empfänger der Vergütung zur Einspeisung,SG10,,,,,,,Muss [55],[55] Wenn SG10 CCI+Z22++Z91 (Status der erzeugenden Marktlokation: Veräußerungsform Geförderte Direktvermarktung bzw. Marktprämie) vorhanden + 367,Empfänger der Vergütung zur Einspeisung,SG10,CCI,,00246,,,,Muss, + 368,Empfänger der Vergütung zur Einspeisung,SG10,CCI,7037,00246,Z89,,Empfänger derVergütung,X, + 369,Empfänger der Vergütung zur Einspeisung,SG10,CAV,,00247,,,,Muss, + 370,Empfänger der Vergütung zur Einspeisung,SG10,CAV,7110,00247,Z10,,Kunde,X, + 371,Empfänger der Vergütung zur Einspeisung,SG10,CAV,7110,,Z11,,Lieferant,X, + 372,Basis zur Bildung der Tranchengröße,SG10,,,,,,,Muss[124] ∧[627],"[124] Wenn in derselben SG8 SEQ+Z15 (Daten der Tranche) das RFF+Z20 (Referenz auf die ID der Tranche) nicht vorhanden + [627] Hinweis: Bei Geschäftsvorfall 1 und 3" + 373,Basis zur Bildung der Tranchengröße,SG10,CCI,,00248,,,,Muss, + 374,Basis zur Bildung der Tranchengröße,SG10,CCI,7059,00248,Z37,,Basis zur Bildung derTranchengröße,X, + 375,Basis zur Bildung der Tranchengröße,SG10,CCI,7037,00248,ZD1,,Prozentual,X, + 376,Basis zur Bildung der Tranchengröße,SG10,CCI,7037,,ZD2,,Aufteilungsfaktorauf Basis vonReferenzenträger/installierter Leistung,X, + 377,OBIS-Daten der Tranche,SG8,,,,,,,,"[2311] Für jede ID im SG5 LOC+Z21 (Tranche) DE3225, mindestens einmal anzugeben" + 378,OBIS-Daten der Tranche,SG8,SEQ,,00260,,,,, + 379,OBIS-Daten der Tranche,SG8,SEQ,1229,00260,Z17,,OBIS-Daten derTranche,, + 380,Referenz auf die ID einer Tranche,SG8,RFF,,00261,,,,, + 381,Referenz auf die ID einer Tranche,SG8,RFF,1153,00261,Z20,,Tranche,, + 382,Referenz auf die ID einer Tranche,SG8,RFF,1154,00261,,,ID einer Tranche,,[950] Format: Marktlokations-ID + 383,OBIS-Kennzahl der Tranche,SG8,PIA,,00262,,,,, + 384,OBIS-Kennzahl der Tranche,SG8,PIA,4347,00262,5,,Produktidentifikation,, + 385,OBIS-Kennzahl der Tranche,SG8,PIA,7140,00262,,,OBIS-Kennzahl der Tranche,,[269] Es sind alle OBIS-Kennzahlen gem. EDI@Energy Codeliste der OBIS-Kennzahlen und Medien für den deutschen Energiemarkt Kap.3 + 386,OBIS-Kennzahl der Tranche,SG8,PIA,7143,00262,SRW,,OBIS-Kennzahl,, + 387,OBIS Daten für Lieferant relevant,SG10,,,,,,,, + 388,OBIS Daten für Lieferant relevant,SG10,CCI,,00265,,,,, + 389,OBIS Daten für Lieferant relevant,SG10,CCI,7037,00265,ZA7,,LF,, + 390,Verwendungszweck der Werte,SG10,CAV,,00266,,,,, + 391,Verwendungszweck der Werte,SG10,CAV,7111,00266,Z85,,Bilanzkreisabrechnung,, + 392,Verwendungszweck der Werte,SG10,CAV,7111,,Z47,,Endkundenabrechnung,, + 393,Daten der Technischen Ressource,SG8,,,,,,,,"[296] Wenn SG5 LOC+Z20 (Technische Ressource) vorhanden + [2357] Je SG5 LOC+Z20 (Technische Ressource) ist genau einmal die Segmentgruppe anzugeben" + 394,Daten der Technischen Ressource,SG8,SEQ,,00273,,,,, + 395,Daten der Technischen Ressource,SG8,SEQ,1229,00273,Z52,,Daten derTechnischenRessource,, + 396,Referenz auf die ID der Technischen Ressource,SG8,RFF,,00274,,,,, + 397,Referenz auf die ID der Technischen Ressource,SG8,RFF,1153,00274,Z37,,TechnischeRessource,, + 398,Referenz auf die ID der Technischen Ressource,SG8,RFF,1154,00274,,,ID der TechnischenRessource,,[922] Format: TR-ID + 399,Referenz auf die ID der vorgelagerten Messlokation ,SG8,RFF,,00275,,,,,[166] Wenn + 400,Referenz auf die ID der vorgelagerten Messlokation ,SG8,RFF,1153,00275,Z34,,vorgelagerteMesslokation,, + 401,Referenz auf die ID der vorgelagerten Messlokation ,SG8,RFF,1154,00275,,,ID einer Lokation,,[951] Format: Zählpunktbezeichnung + 402,Referenz auf die der Technischen Ressource zugeordneten Marktlokation ,SG8,RFF,,00276,,,,,[668] Hinweis: Dieses Segment wird nach Abschluss der Einführung der Lokationsbündelstrukt ur zum 01.10.2025 aus der UTILMD entfernt + 403,Referenz auf die der Technischen Ressource zugeordneten Marktlokation ,SG8,RFF,1153,00276,Z16,,zugeordneteMarktlokation,, + 404,Referenz auf die der Technischen Ressource zugeordneten Marktlokation ,SG8,RFF,1154,00276,,,ID der Marktlokation,,[950] Format: Marktlokations-ID + 405,Referenz auf die der Technischen Ressource zugeordneten Steuerbaren Ressource,SG8,RFF,,00277,,,,,"[166] Wenn vorhanden + [699] Hinweis: Es ist die ID der Steuerbare Ressource zu nennen über die die Technische Ressource gesteuert wird" + 406,Referenz auf die der Technischen Ressource zugeordneten Steuerbaren Ressource,SG8,RFF,1153,00277,Z38,,SteuerbareRessource,, + 407,Referenz auf die der Technischen Ressource zugeordneten Steuerbaren Ressource,SG8,RFF,1154,00277,,,ID der SteuerbarenRessource,,[961] Format: SR-ID + 408,Referenz auf die der Technischen Ressource zugeordneten Netzlokation,SG8,RFF,,00278,,,,,"[166] Wenn vorhanden + [700] Hinweis: Es ist die ID der Netzlokation zu nennen über die die Technische Ressource gesteuert wird" + 409,Referenz auf die der Technischen Ressource zugeordneten Netzlokation,SG8,RFF,1153,00278,Z32,,Netzlokation,, + 410,Referenz auf die der Technischen Ressource zugeordneten Netzlokation,SG8,RFF,1154,00278,,,ID der Netzlokation,,[960] Format: Netzlokations-ID + 411,Nennleistung (Aufnahme),SG9,,,,,,,,[448] Wenn in derselben SG8 das CCI+Z56 (Speicher) vorhanden + 412,Nennleistung (Aufnahme),SG9,QTY,,00279,,,,, + 413,Nennleistung (Aufnahme),SG9,QTY,6063,00279,Z43,,Nennleistung(Aufnahme),, + 414,Nennleistung (Aufnahme),SG9,QTY,6060,00279,,,Menge,, + 415,Nennleistung (Aufnahme),SG9,QTY,6411,00279,KWT,,Kilowatt,, + 416,Nennleistung (Abgabe),SG9,,,,,,,,"[447] Wenn in derselben SG8 das CCI+Z50 (Stromerzeugungsart) vorhanden + [448] Wenn in derselben SG8 das CCI+Z56 (Speicher) vorhanden" + 417,Nennleistung (Abgabe),SG9,QTY,,00280,,,,, + 418,Nennleistung (Abgabe),SG9,QTY,6063,00280,Z44,,Nennleistung(Abgabe),, + 419,Nennleistung (Abgabe),SG9,QTY,6060,00280,,,Menge,, + 420,Nennleistung (Abgabe),SG9,QTY,6411,00280,KWT,,Kilowatt,, + 421,Speicherkapazität,SG9,,,,,,,,[448] Wenn in derselben SG8 das CCI+Z56 (Speicher) vorhanden + 422,Speicherkapazität,SG9,QTY,,00281,,,,, + 423,Speicherkapazität,SG9,QTY,6063,00281,Z42,,Speicherkapazität,, + 424,Speicherkapazität,SG9,QTY,6060,00281,,,Menge,, + 425,Speicherkapazität,SG9,QTY,6411,00281,KWH,,Kilowattstunde,, + 426,Art und Nutzung der Technischen Ressource,SG10,,,,,,,, + 427,Art und Nutzung der Technischen Ressource,SG10,CCI,,00282,,,,, + 428,Art und Nutzung der Technischen Ressource,SG10,CCI,7059,00282,Z17,,Stromverbrauchsart,, + 429,Art und Nutzung der Technischen Ressource,SG10,CCI,7059,,Z50,,Stromerzeugungsart,, + 430,Art und Nutzung der Technischen Ressource,SG10,CCI,7059,,Z56,,Speicher,, + 431,Erzeugungsart,SG10,CAV,,00286,,,,,[447] Wenn in derselben SG8 das CCI+Z50 (Stromerzeugungsart) vorhanden + 432,Erzeugungsart,SG10,CAV,7111,00286,ZF5,,Solar,, + 433,Erzeugungsart,SG10,CAV,7111,,ZF6,,Wind,, + 434,Erzeugungsart,SG10,CAV,7111,,ZG0,,Gas,, + 435,Erzeugungsart,SG10,CAV,7111,,ZG1,,Wasser,, + 436,Erzeugungsart,SG10,CAV,7111,,ZG5,,SonstigeErzeugungsart,, + 437,Speicherart,SG10,CAV,,00287,,,,,[448] Wenn in derselben SG8 das CCI+Z56 (Speicher) vorhanden + 438,Speicherart,SG10,CAV,7111,00287,ZF7,,Wasserstoffspeicher,, + 439,Speicherart,SG10,CAV,7111,,ZF8,,Pumpspeicher,, + 440,Speicherart,SG10,CAV,7111,,ZF9,,Batteriespeicher,, + 441,Speicherart,SG10,CAV,7111,,ZG6,,Sonstige Speicherart,, + 442,Daten der Steuerbaren Ressource,SG8,,,,,,,,"[205] Wenn SG5 LOC+Z19 (Steuerbare Ressource) vorhanden + [2358] Je SG5 LOC+Z19 (Steuerbare Ressource) ist genau einmal die Segmentgruppe anzugeben" + 443,Daten der Steuerbaren Ressource,SG8,SEQ,,00293,,,,, + 444,Daten der Steuerbaren Ressource,SG8,SEQ,1229,00293,Z62,,Daten derSteuerbarenRessource,, + 445,Referenz auf die ID der Steuerbaren Ressource,SG8,RFF,,00294,,,,, + 446,Referenz auf die ID der Steuerbaren Ressource,SG8,RFF,1153,00294,Z38,,SteuerbareRessource,, + 447,Referenz auf die ID der Steuerbaren Ressource,SG8,RFF,1154,00294,,,ID der SteuerbarenRessource,,[961] Format: SR-ID + 448,Steuerkanal,SG10,,,,,,,, + 449,Steuerkanal,SG10,CCI,,00295,,,,, + 450,Steuerkanal,SG10,CCI,7059,00295,Z49,,Steuerkanal,, + 451,Leistungsbeschreibung des Steuerkanals,SG10,CAV,,00296,,,,, + 452,Leistungsbeschreibung des Steuerkanals,SG10,CAV,7111,00296,ZF2,,Leistungsbeschreibung des Steuerkanals,, + 453,Leistungsbeschreibung des Steuerkanals,SG10,CAV,1131,00296,Z14,,An/Aus,, + 454,Leistungsbeschreibung des Steuerkanals,SG10,CAV,1131,,Z15,,Gestuft,, + 455,Zugeordnete Marktpartner,SG10,,,,,,,, + 456,Zugeordnete Marktpartner,SG10,CCI,,00297,,,,, + 457,Zugeordnete Marktpartner,SG10,CCI,7037,00297,ZB3,,ZugeordneterMarktpartner,, + 458,Messstellenbetreiber,SG10,CAV,,00298,,,,, + 459,Messstellenbetreiber,SG10,CAV,7111,00298,Z91,,MSB,, + 460,Messstellenbetreiber,SG10,CAV,1131,00298,,,MP-ID,, + 461,Messstellenbetreiber,SG10,CAV,7110,00298,Z39,,GrundzuständigerMessstellenbetreiber,, + 462,Messstellenbetreiber,SG10,CAV,7110,,Z40,,WettbewerblicherMessstellenbetreiber,, + 463,Messstellenbetreiber,SG10,CAV,7110,,Z41,,Auffangmessstellenbetreiber,, + 464,Produkt-Daten der Steuerbaren Ressource,SG8,,,,,,,,[166] Wenn + 465,Produkt-Daten der Steuerbaren Ressource,SG8,SEQ,,00299,,,,, + 466,Produkt-Daten der Steuerbaren Ressource,SG8,SEQ,1229,00299,Z61,,Produkt-Daten derSteuerbarenRessource,, + 467,Referenz auf die ID der Steuerbaren Ressource,SG8,RFF,,00300,,,,, + 468,Referenz auf die ID der Steuerbaren Ressource,SG8,RFF,1153,00300,Z38,,SteuerbareRessource,, + 469,Referenz auf die ID der Steuerbaren Ressource,SG8,RFF,1154,00300,,,ID einer SteuerbarenRessource,,[961] Format: SR-ID + 470,Produkt-Daten der Steuerbaren Ressource,SG8,PIA,,00301,,,,, + 471,Produkt-Daten der Steuerbaren Ressource,SG8,PIA,4347,00301,5,,Produktidentifikation,, + 472,Produkt-Daten der Steuerbaren Ressource,SG8,PIA,7140,00301,,,Konfigurationsprodukt-Code,, + 473,Produkt-Daten der Steuerbaren Ressource,SG8,PIA,7143,00301,Z12,,Konfigurationsprodukt,, + 474,Zugeordnete Definition,SG10,,,,,,,, + 475,Zugeordnete Definition,SG10,CCI,,00302,,,,, + 476,Zugeordnete Definition,SG10,CCI,7059,00302,Z52,,Code derSchaltzeitdefinition,, + 477,Zugeordnete Definition,SG10,CCI,7059,,Z53,,Code derLeistungskurvendefinition,, + 478,Zugeordnete Definition,SG10,CCI,7037,00302,,,Code der Definition,, + 479,Auftraggebender Marktpartner,SG10,,,,,,,, + 480,Auftraggebender Marktpartner,SG10,CCI,,00303,,,,, + 481,Auftraggebender Marktpartner,SG10,CCI,7037,00303,ZB3,,ZugeordneterMarktpartner,, + 482,Auftraggebender Marktpartner,SG10,CAV,,00304,,,,, + 483,Auftraggebender Marktpartner,SG10,CAV,7111,00304,Z88,,NB,, + 484,Auftraggebender Marktpartner,SG10,CAV,7111,,Z89,,LF,, + 485,Auftraggebender Marktpartner,SG10,CAV,1131,00304,,,MP-ID,, + 486,Produkt-Daten für Marktrolle relevant,SG10,,,,,,,, + 487,Produkt-Daten für Marktrolle relevant,SG10,CCI,,00305,,,,, + 488,Produkt-Daten für Marktrolle relevant,SG10,CCI,7037,00305,ZA7,,LF,, + 489,Daten der Messlokation,SG8,,,,,,,,[2284] Für jede Messlokations-ID im SG5 LOC+Z17 (Messlokation) DE3225 genau einmal anzugeben + 490,Daten der Messlokation,SG8,SEQ,,00306,,,,, + 491,Daten der Messlokation,SG8,SEQ,1229,00306,Z18,,Daten derMesslokation,, + 492,Referenz auf die ID der Messlokation,SG8,RFF,,00307,,,,, + 493,Referenz auf die ID der Messlokation,SG8,RFF,1153,00307,Z19,,Messlokation,, + 494,Referenz auf die ID der Messlokation,SG8,RFF,1154,00307,,,ID der Messlokation,,[951] Format: Zählpunktbezeichnung + 495,Abrechnung des Messstellenbetriebs über NNE für kME,SG8,RFF,,00309,,,,,"[235] Wenn das RFF+Z19 (Messlokation) aus dieser SG8 auf das gleiche SG5 LOC+Z17 (Messlokation), wie ein RFF+Z19 (Messlokation) aus einer SG8 SEQ+Z03 (Zähleinrichtungsdate n), in dem SG10 CCI+++E13 CAV+MME (Zählertyp: mME) nicht vorhanden ist, referenziert" + 496,Abrechnung des Messstellenbetriebs über NNE für kME,SG8,RFF,1153,00309,Z05,,Abrechnung desMessstellenbetriebsüber NNE für kME,, + 497,Abrechnung des Messstellenbetriebs über NNE für kME,SG8,RFF,1154,00309,,,Abrechnung über NNE (Ja/Nein),, + 498,Zugeordnete Marktpartner,SG10,,,,,,,, + 499,Zugeordnete Marktpartner,SG10,CCI,,00310,,,,, + 500,Zugeordnete Marktpartner,SG10,CCI,7037,00310,ZB3,,ZugeordneterMarktpartner,, + 501,Messstellenbetreiber,SG10,CAV,,00311,,,,, + 502,Messstellenbetreiber,SG10,CAV,7111,00311,Z91,,MSB,, + 503,Messstellenbetreiber,SG10,CAV,1131,00311,,,MP-ID,, + 504,Messstellenbetreiber,SG10,CAV,7110,00311,Z19,,Auf vertraglicherGrundlagegegenüberAnschlussnutzer /Anschlussnehmer,, + 505,Messstellenbetreiber,SG10,CAV,7110,,Z20,,In der Ausübung derWeiterverpflichtungdurch den gMSB,, + 506,Messstellenbetreiber,SG10,CAV,7110,00311,Z39,,GrundzuständigerMessstellenbetreiber,, + 507,Messstellenbetreiber,SG10,CAV,7110,,Z40,,WettbewerblicherMessstellenbetreiber,, + 508,Messstellenbetreiber,SG10,CAV,7110,,Z41,,Auffangmessstellenbetreiber,, + 509,Grundzuständiger Messstellenbetreiber,SG10,CAV,,00312,,,,, + 510,Grundzuständiger Messstellenbetreiber,SG10,CAV,7111,00312,ZF0,,gMSB,, + 511,Grundzuständiger Messstellenbetreiber,SG10,CAV,1131,00312,,,MP-ID,, + 512,Spannungsebene der Messlokation,SG10,,,,,,,, + 513,Spannungsebene der Messlokation,SG10,CCI,,00314,,,,, + 514,Spannungsebene der Messlokation,SG10,CCI,7037,00314,E04,,Spannungsebeneder Messlokation,, + 515,Spannungsebene der Messlokation,SG10,CAV,,00315,,,,, + 516,Spannungsebene der Messlokation,SG10,CAV,7111,00315,E03,,Höchstspannung,, + 517,Zähleinrichtungsdaten,SG8,,,,,,,,"[40] Wenn SG4 STS+7++E02 (Transaktionsgrund: Einzug in Neuanlage) vorhanden + [130] Wenn an Messlokation vorhanden + [143] Wenn STS+7++E03 (Transaktionsgrund: Wechsel) vorhanden + [2309] Für jede ID im SG5 LOC+Z17 (Messlokation) DE3225 mindestens einmal anzugeben" + 518,Zähleinrichtungsdaten,SG8,SEQ,,00326,,,,, + 519,Zähleinrichtungsdaten,SG8,SEQ,1229,00326,Z03,,Zähleinrichtungsdaten,, + 520,Referenz auf die ID einer Messlokation,SG8,RFF,,00327,,,,, + 521,Referenz auf die ID einer Messlokation,SG8,RFF,1153,00327,Z19,,Messlokation,, + 522,Referenz auf die ID einer Messlokation,SG8,RFF,1154,00327,,,ID einer Messlokation,,[951] Format: Zählpunktbezeichnung + 523,Referenz auf das Smartmeter-Gateway,SG8,RFF,,00328,,,,,"[166] Wenn vorhanden + [215] Wenn in derselben SG8 SEQ+Z03 (Zähleinrichtungsdate n) SG10 CCI+++E13 CAV+MME (Zählertyp: mME) vorhanden" + 524,Referenz auf das Smartmeter-Gateway,SG8,RFF,1153,00328,Z14,,Smartmeter-,, + 525,Referenz auf das Smartmeter-Gateway,SG8,RFF,1154,00328,,,Identifikation / Nummer desSmartmeter-Gateways,, + 526,Zählertyp,SG10,,,,,,,, + 527,Zählertyp,SG10,CCI,,00329,,,,, + 528,Zählertyp,SG10,CCI,7037,00329,E13,,Zählertyp,, + 529,Zählertyp,SG10,CAV,,00330,,,,, + 530,Zählertyp,SG10,CAV,7111,00330,AHZ,,analogerHaushaltszähler(Drehstrom),, + 531,Zählertyp,SG10,CAV,7111,,WSZ,,analogerWechselstromzähler,, + 532,Zählertyp,SG10,CAV,7111,,LAZ,,Lastgangzähler,, + 533,Zählertyp,SG10,CAV,7111,,MAZ,,Maximumzähler,, + 534,Zählertyp,SG10,CAV,7111,,MME,,moderneMesseinrichtungnach MsbG,, + 535,Zählertyp,SG10,CAV,7111,,EHZ,,elektronischerHaushaltszähler,, + 536,Zählertyp,SG10,CAV,7111,,IVA,,IndividuelleAbstimmung(Sonderausstattung),, + 537,Zählertyp,SG10,CAV,7110,00330,Z01,,EDL40,, + 538,Zählertyp,SG10,CAV,7110,,Z02,,EDL21,, + 539,Zählertyp,SG10,CAV,7110,,Z03,,sonstiger EHZ,, + 540,Zählertyp,SG10,CAV,7110,,Z04,,Standard,, + 541,Zählertyp,SG10,CAV,7110,,Z05,,MeDa-Zähler,,"[136] Wenn SG10 CCI+++E13 (Zählertyp) CAV+EHZ (elektronischer Haushaltszähler) vorhanden + [346] Wenn SG10 CCI+++E13 (Zählertyp) CAV+MME (mME) vorhanden" + 542,Identifikation / Nummer des Gerätes,SG10,CAV,,00331,,,,, + 543,Identifikation / Nummer des Gerätes,SG10,CAV,7111,00331,Z30,,Gerätenummer,, + 544,Identifikation / Nummer des Gerätes,SG10,CAV,7110,00331,,,Gerätenummer,, + 545,Registeranzahl,SG10,CAV,,00332,,,,,[139] Wenn SG10 CAV+IVA (Individuelle Abstimmung) nicht + 546,Registeranzahl,SG10,CAV,7111,00332,ETZ,,Eintarif,, + 547,Registeranzahl,SG10,CAV,7111,,ZTZ,,Zweitarif,, + 548,Registeranzahl,SG10,CAV,7111,,NTZ,,Mehrtarif,, + 549,Energierichtung,SG10,CAV,,00333,,,,, + 550,Energierichtung,SG10,CAV,7111,00333,ERZ,,Einrichtungszähler,, + 551,Energierichtung,SG10,CAV,7111,,ZRZ,,Zweirichtungszähler,, + 552,Fernschaltung der Zähleinrichtung,SG10,CAV,,00334,,,,, + 553,Fernschaltung der Zähleinrichtung,SG10,CAV,7111,00334,Z58,,Fernschaltung derZähleinrichtung,, + 554,Fernschaltung der Zähleinrichtung,SG10,CAV,7110,00334,Z06,,vorhanden,, + 555,Fernschaltung der Zähleinrichtung,SG10,CAV,7110,,Z07,,nicht vorhanden,, + 556,Messwerterfassung an der Zähleinrichtung,SG10,,,,,,,,[316] Wenn in derselben SG8 das RFF+Z14 (Smartmeter- Gateway) nicht vorhanden + 557,Messwerterfassung an der Zähleinrichtung,SG10,CCI,,00337,,,,, + 558,Messwerterfassung an der Zähleinrichtung,SG10,CCI,7037,00337,E12,,Messwerterfassungan derZähleinrichtung,, + 559,Messwerterfassung an der Zähleinrichtung,SG10,CAV,,00338,,,,, + 560,Messwerterfassung an der Zähleinrichtung,SG10,CAV,7111,00338,AMR,,fernauslesbareZähler,, + 561,Messwerterfassung an der Zähleinrichtung,SG10,CAV,7111,,MMR,,manuellausgelesene Zähler,, + 562,OBIS-Daten der Zähleinrichtung / Smartmeter-Gateway,SG8,,,,,,,,[121] Wenn in dem SEQ+Z03 (Zähleinrichtungsdate n) das SG8 RFF+Z14 (Referenz auf das Smartmeter-Gateway) + 563,OBIS-Daten der Zähleinrichtung / Smartmeter-Gateway,SG8,SEQ,,00339,,,,, + 564,OBIS-Daten der Zähleinrichtung / Smartmeter-Gateway,SG8,SEQ,1229,00339,Z20,,OBIS-Daten derZähleinrichtung,, + 565,Referenz auf die Gerätenummer,SG8,RFF,,00340,,,,,[665] Hinweis: Wenn ein Zähler mit einem SMGW parametriert ist werden an dem Zähler keine OBIS- Kennzahlen angegeben Hier gibt es nur OBIS Kennzahlen vom SMGW + 566,Referenz auf die Gerätenummer,SG8,RFF,1153,00340,MG,,Gerätenummer desZählers,, + 567,Referenz auf die Gerätenummer,SG8,RFF,1153,,Z14,,Smartmeter-Gateway,,[441] Wenn im SG8+SEQ+Z03 (Zähleinrichtungsdate n) für die in diesem RFF DE1154 genannte Gerätenummer eines Zählers das RFF+Z14 (Referenz auf das Smartmeter-Gateway) nicht vorhanden ist + 568,Referenz auf die Gerätenummer,SG8,RFF,1154,00340,,,Gerätenummer,, + 569,Referenz auf die ID einer Messlokation,SG8,RFF,,00341,,,,, + 570,Referenz auf die ID einer Messlokation,SG8,RFF,1153,00341,Z19,,Messlokation,, + 571,Referenz auf die ID einer Messlokation,SG8,RFF,1154,00341,,,ID einer Messlokation,,[951] Format: Zählpunktbezeichnung + 572,Konfigurations-ID,SG8,RFF,,00343,,,,,"[402] Wenn in derselben SG8 SEQ+Z20 (OBIS-Daten der Zähleinrichtung / Smartmeter-Gateway) eine OBIS-Kennzahl der Werteart ""Zählerstand"" im PIA+5 vorhanden + [420] Wenn in dieser SG8 das RFF+Z14 (Smartmeter- Gateway) vorhanden ist" + 573,Konfigurations-ID,SG8,RFF,1153,00343,AGK,,Anwendungsreferenznummer,, + 574,Konfigurations-ID,SG8,RFF,1154,00343,,,"Referenz, Identifikation",, + 575,OBIS-Kennzahl der Zähleinrichtung / Smartmeter-Gateway,SG8,PIA,,00344,,,,, + 576,OBIS-Kennzahl der Zähleinrichtung / Smartmeter-Gateway,SG8,PIA,4347,00344,5,,Produktidentifikation,, + 577,OBIS-Kennzahl der Zähleinrichtung / Smartmeter-Gateway,SG8,PIA,7140,00344,,,OBIS-Kennzahl derZähleinrichtung,,"[323] Es sind alle OBIS-Kennzahlen gem. EDI@Energy Codeliste der OBIS-Kennzahlen und Medien für den deutschen Energiemarkt Kap. 3. anzugeben, welche an der Zähleinrichtung genutzt werden. Der Mindestumfang der OBIS-Kennzahlen ergibt sich aus den genannten" + 578,OBIS-Kennzahl der Zähleinrichtung / Smartmeter-Gateway,SG8,PIA,7143,00344,SRW,,OBIS-Kennzahl,, + 579,Wertegranularität,SG10,,,,,,,,[256] Wenn in derselben SG8 SEQ+Z20 (OBIS-Daten der Zähleinrichtung / Smartmeter-Gateway) das PIA+5+1-b?:1.8.e / 1-b?:2.8.e vorhanden + 580,Wertegranularität,SG10,CCI,,00345,,,,, + 581,Wertegranularität,SG10,CCI,7037,00345,ZE4,,Wertegranularität,, + 582,Wertegranularität,SG10,CAV,,00346,,,,, + 583,Wertegranularität,SG10,CAV,7111,00346,ZD9,,Jährlich,, + 584,Wertegranularität,SG10,CAV,7111,,ZE8,,Halbjährlich,, + 585,Wertegranularität,SG10,CAV,7111,,ZE9,,Quartalsweise,, + 586,Wertegranularität,SG10,CAV,7111,,ZB7,,Monatlich,, + 587,Vor- und Nachkommastellen des Zählwerks,SG10,,,,,,,,[273] Wenn in derselben SG8 SEQ+Z20 (OBIS-Daten der Zähleinrichtung / Smartmeter-Gateway) das PIA+5+1-b?:1.8.e / 1-b?:2.8.e / 1-b?:3.8.e / 1-b?:4.8.e / 1-b?:5. 8.e / 1-b?:6.8.e / 1- b?:7.8.e / 1-b?:8.8.e / 1-b?:1.8.63 vorhanden + 588,Vor- und Nachkommastellen des Zählwerks,SG10,CCI,,00349,,,,, + 589,Vor- und Nachkommastellen des Zählwerks,SG10,CCI,7059,00349,11,,Produkt,, + 590,Vor- und Nachkommastellen des Zählwerks,SG10,CCI,7037,00349,Z33,,Vor- undNachkommastellendes Zählwerkes,, + 591,Vor- und Nachkommastellen des Zählwerks,SG10,CAV,,00350,,,,, + 592,Vor- und Nachkommastellen des Zählwerks,SG10,CAV,7110,00350,,,Angabe derVorkommastelle,, + 593,Vor- und Nachkommastellen des Zählwerks,SG10,CAV,7110,00350,,,Angabe derNachkommastelle,, + 594,Bezeichnung des Zählwerks auf dem Gerät,SG10,,,,,,,,"[123] Wenn noch mindestens eine weitere SG8 SEQ+Z20 (OBIS-Daten der Zähleinrichtung Smartmeter-Gateway) mit dem SG8 RFF+MG (Gerätenummer des Zählers) auf die gleiche Identifikation/ Nummer des Gerätes referenziert + [273] Wenn in derselben SG8 SEQ+Z20 (OBIS-Daten der Zähleinrichtung / Smartmeter-Gateway) das PIA+5+1-b?:1.8.e / 1-b?:2.8.e / 1-b?:3.8.e / 1-b?:4.8.e / 1-b?:5. 8.e / 1-b?:6.8.e / 1- b?:7.8.e / 1-b?:8.8.e / 1-b?:1.8.63 vorhanden" + 595,Bezeichnung des Zählwerks auf dem Gerät,SG10,CCI,,00351,,,,, + 596,Bezeichnung des Zählwerks auf dem Gerät,SG10,CCI,7037,00351,Z63,,LokaleKennzeichnung zuKontrollzwecken,, + 597,Bezeichnung des Zählwerks auf dem Gerät,SG10,CCI,7036,00351,,,Bezeichnung des Zählwerksauf dem Gerät,, + 598,Wandlerdaten,SG8,,,,,,,,[130] Wenn an Messlokation vorhanden + 599,Wandlerdaten,SG8,SEQ,,00353,,,,, + 600,Wandlerdaten,SG8,SEQ,1229,00353,Z04,,Wandler-Daten,, + 601,Referenz auf die Gerätenummer,SG8,RFF,,00354,,,,, + 602,Referenz auf die Gerätenummer,SG8,RFF,1153,00354,MG,,Gerätenummer desZählers,, + 603,Referenz auf die Gerätenummer,SG8,RFF,1154,00354,,,Gerätenummer,, + 604,Wandler,SG10,,,,,,,, + 605,Wandler,SG10,CCI,,00355,,,,, + 606,Wandler,SG10,CCI,7037,00355,Z25,,Wandler,, + 607,Identifikation / Nummer des Gerätes,SG10,CAV,,00356,,,,,"[2317] Wenn in derselben SG8 SEQ+Z04 (Wandlerdaten) das SG10 CCI+++Z25 (Wandler) CAV+MIW/MPW/ MUW vorhanden, ist das Segment mindestens zweimal anzugeben + [2318] Wenn in derselben SG8 SEQ+Z04 (Wandlerdaten) das SG10 CCI+++Z25 (Wandler) CAV+MBW (Blockstromwandler) vorhanden, ist das Segment genau einmal anzugeben" + 608,Identifikation / Nummer des Gerätes,SG10,CAV,7111,00356,Z30,,Gerätenummer,, + 609,Identifikation / Nummer des Gerätes,SG10,CAV,7110,00356,,,Gerätenummer,, + 610,Wandlertyp und Faktor,SG10,CAV,,00357,,,,, + 611,Wandlertyp und Faktor,SG10,CAV,7111,00357,MIW,,MesswandlersatzStrom,, + 612,Wandlertyp und Faktor,SG10,CAV,7111,,MPW,,Kombimesswandlersatz (Strom undSpannung),, + 613,Wandlertyp und Faktor,SG10,CAV,7111,,MBW,,Blockstromwandler,, + 614,Wandlertyp und Faktor,SG10,CAV,7111,,MUW,,MesswandlersatzSpannung,, + 615,Wandlertyp und Faktor,SG10,CAV,7110,00357,,,Wandlerfaktor,,"[141] Wenn SG10 CAV+MIW/ MPW/ MBW vorhanden + [902] Format:" + 616,Kommunikationseinrichtu ngsdaten,SG8,,,,,,,,"[130] Wenn an Messlokation vorhanden + [2119] Je SG8 SEQ+Z13 (Smartmeter- Gateway) ist genau einmal die Segmentgruppe anzugeben" + 617,Kommunikationseinrichtu ngsdaten,SG8,SEQ,,00358,,,,, + 618,Kommunikationseinrichtu ngsdaten,SG8,SEQ,1229,00358,Z05,,Kommunikationseinrichtungsdaten,, + 619,Referenz auf die Gerätenummer,SG8,RFF,,00359,,,,, + 620,Referenz auf die Gerätenummer,SG8,RFF,1153,00359,MG,,Gerätenummer desZählers,, + 621,Referenz auf die Gerätenummer,SG8,RFF,1154,00359,,,Gerätenummer,, + 622,Kommunikationseinrichtu ng,SG10,,,,,,,, + 623,Kommunikationseinrichtu ng,SG10,CCI,,00360,,,,, + 624,Kommunikationseinrichtu ng,SG10,CCI,7037,00360,Z26,,Kommunikationseinrichtung,, + 625,Identifikation / Nummer des Gerätes,SG10,CAV,,00361,,,,, + 626,Identifikation / Nummer des Gerätes,SG10,CAV,7111,00361,Z30,,Gerätenummer,, + 627,Identifikation / Nummer des Gerätes,SG10,CAV,7110,00361,,,Gerätenummer,, + 628,Kommunikationseinrichtu ngstyp,SG10,CAV,,00362,,,,, + 629,Kommunikationseinrichtu ngstyp,SG10,CAV,7111,00362,GSM,,GSM/GPRS/UMTS-Kom.-Einr.,, + 630,Kommunikationseinrichtu ngstyp,SG10,CAV,7111,,ETH,,Ethernet-Kom.-Einricht. LAN/WLAN,, + 631,Kommunikationseinrichtu ngstyp,SG10,CAV,7111,,PLC,,PLC-Kom.-Einrichtung,, + 632,Kommunikationseinrichtu ngstyp,SG10,CAV,7111,,PST,,Festnetz-Kom.-,, + 633,Daten der technischen Steuereinrichtung,SG8,,,,,,,,[130] Wenn an Messlokation vorhanden + 634,Daten der technischen Steuereinrichtung,SG8,SEQ,,00363,,,,, + 635,Daten der technischen Steuereinrichtung,SG8,SEQ,1229,00363,Z06,,Daten dertechnischenSteuereinrichtung,, + 636,Referenz auf die Gerätenummer,SG8,RFF,,00364,,,,, + 637,Referenz auf die Gerätenummer,SG8,RFF,1153,00364,MG,,Gerätenummer desZählers,, + 638,Referenz auf die Gerätenummer,SG8,RFF,1154,00364,,,Gerätenummer,, + 639,Technische Steuereinrichtung,SG10,,,,,,,, + 640,Technische Steuereinrichtung,SG10,CCI,,00365,,,,, + 641,Technische Steuereinrichtung,SG10,CCI,7037,00365,Z27,,TechnischeSteuereinrichtung,, + 642,Identifikation / Nummer des Gerätes,SG10,CAV,,00366,,,,, + 643,Identifikation / Nummer des Gerätes,SG10,CAV,7111,00366,Z30,,Gerätenummer,, + 644,Identifikation / Nummer des Gerätes,SG10,CAV,7110,00366,,,Gerätenummer,, + 645,Technische Steuereinrichtungstyp,SG10,CAV,,00367,,,,, + 646,Technische Steuereinrichtungstyp,SG10,CAV,7111,00367,RSU,,Rundsteuerempfänger,, + 647,Technische Steuereinrichtungstyp,SG10,CAV,7111,,TSU,,Tarifschaltuhr,, + 648,Smartmeter-Gateway,SG8,,,,,,,,[130] Wenn an Messlokation vorhanden + 649,Smartmeter-Gateway,SG8,SEQ,,00368,,,,, + 650,Smartmeter-Gateway,SG8,SEQ,1229,00368,Z13,,Smartmeter-Gateway,, + 651,Smartmeter-Gateway,SG10,,,,,,,, + 652,Smartmeter-Gateway,SG10,CCI,,00369,,,,, + 653,Smartmeter-Gateway,SG10,CCI,7037,00369,Z75,,Smartmeter-Gateway,, + 654,Identifikation / Nummer des Gerätes,SG10,CAV,,00370,,,,, + 655,Identifikation / Nummer des Gerätes,SG10,CAV,7111,00370,Z30,,Gerätenummer,, + 656,Identifikation / Nummer des Gerätes,SG10,CAV,7110,00370,,,Gerätenummer,,[952] Format: Gerätenummer nach DIN 43863-5 + 657,Daten der Steuerbox,SG8,,,,,,,,[133] Wenn an der übermittelten Marktlokation / Messlokation vorhanden + 658,Daten der Steuerbox,SG8,SEQ,,00371,,,,, + 659,Daten der Steuerbox,SG8,SEQ,1229,00371,Z14,,Steuerbox,, + 660,Referenz auf das Smartmeter-Gateway,SG8,RFF,,00372,,,,, + 661,Referenz auf das Smartmeter-Gateway,SG8,RFF,1153,00372,Z14,,Smartmeter-Gateway,, + 662,Referenz auf das Smartmeter-Gateway,SG8,RFF,1154,00372,,,Identifikation / Nummer desSmartmeter-Gateways,, + 663,Referenz auf die ID der Marktlokation,SG8,RFF,,00373,,,,, + 664,Referenz auf die ID der Marktlokation,SG8,RFF,1153,00373,Z18,,Marktlokation,, + 665,Referenz auf die ID der Marktlokation,SG8,RFF,1154,00373,,,ID einer Marktlokation,,[950] Format: Marktlokations-ID + 666,Steuerbox,SG10,,,,,,,, + 667,Steuerbox,SG10,CCI,,00374,,,,, + 668,Steuerbox,SG10,CCI,7037,00374,Z76,,Steuerbox,, + 669,Identifikation / Nummer des Gerätes,SG10,CAV,,00375,,,,, + 670,Identifikation / Nummer des Gerätes,SG10,CAV,7111,00375,Z30,,Gerätenummer,, + 671,Identifikation / Nummer des Gerätes,SG10,CAV,7110,00375,,,Gerätenummer,,[952] Format: Gerätenummer nach DIN 43863-5 + 672,Profildaten,SG8,,,,,,,Kann,[119] Wenn in der SG8 SEQ+Z01 SG10 CCI+++ZA6 (Prognosegrundlage der Marktlokation: Prognose auf Basis von Profilen) CAV+E02 (SLP/SEP) vorhanden + 673,Profildaten,SG8,SEQ,,00376,,,,Muss, + 674,Profildaten,SG8,SEQ,1229,00376,Z21,,Profildaten,X, + 675,Referenz auf die ID der Marktlokation,SG8,RFF,,00378,,,,Muss, + 676,Referenz auf die ID der Marktlokation,SG8,RFF,1153,00378,Z18,,Marktlokation,X, + 677,Referenz auf die ID der Marktlokation,SG8,RFF,1154,00378,,,ID einer Marktlokation,X [950],[950] Format: Marktlokations-ID + 678,Normiertes Profil,SG10,,,,,,,Muss, + 679,Normiertes Profil,SG10,CCI,,00380,,,,Muss, + 680,Normiertes Profil,SG10,CCI,7059,00380,Z04,,Standardeinspeiseprofil,X, + 681,Normiertes Profil,SG10,CCI,7037,00380,E01,,synthetischesVerfahren,X, + 682,Normiertes Profil,SG10,CAV,,00381,,,,Muss, + 683,Normiertes Profil,SG10,CAV,7111,00381,,,Code des Normierten Profils,X, + 684,Profilschardaten,SG8,,,,,,,Kann,[89] Wenn im SG8 SEQ+Z01 (Daten der Marktlokation) das SG10 CCI+++ZA6 (Prognosegrundlage der Marktlokation: Prognose auf Basis von Profilen) CAV+E14 (TLP/TEP) vorhanden + 685,Profilschardaten,SG8,SEQ,,00387,,,,Muss, + 686,Profilschardaten,SG8,SEQ,1229,00387,Z08,,Profilschardaten,X, + 687,Referenz auf die ID der Marktlokation,SG8,RFF,,00389,,,,Muss, + 688,Referenz auf die ID der Marktlokation,SG8,RFF,1153,00389,Z18,,Marktlokation,X, + 689,Referenz auf die ID der Marktlokation,SG8,RFF,1154,00389,,,ID einer Marktlokation,X [950],[950] Format: Marktlokations-ID + 690,Profilschar,SG10,,,,,,,Muss, + 691,Profilschar,SG10,CCI,,00397,,,,Muss, + 692,Profilschar,SG10,CCI,7037,00397,Z12,,Profilschar,X, + 693,Profilschar,SG10,CAV,,00398,,,,Muss, + 694,Profilschar,SG10,CAV,7111,00398,,,Code der Profilschar,X, + 695,Normiertes Profil,SG10,,,,,,,Muss, + 696,Normiertes Profil,SG10,CCI,,00399,,,,Muss, + 697,Normiertes Profil,SG10,CCI,7059,00399,Z05,,tagesparameterabhängigesEinspeiseprofil,X, + 698,Normiertes Profil,SG10,CCI,7037,00399,E01,,synthetischesVerfahren,X, + 699,Normiertes Profil,SG10,CCI,7037,,Z10,,analytischesVerfahren,X, + 700,Normiertes Profil,SG10,CAV,,00400,,,,Muss, + 701,Normiertes Profil,SG10,CAV,7111,00400,,,Code des Normierten Profils,X, + 702,Klimazone / Temperaturmessstelle,SG10,,,,,,,, + 703,Klimazone / Temperaturmessstelle,SG10,CCI,,00403,,,,, + 704,Klimazone / Temperaturmessstelle,SG10,CCI,7059,00403,Z99,,Messstelle desTagesparameters(derzeit ist nur dieTemperatur einerlaubterTagesparameter),, + 705,Klimazone / Temperaturmessstelle,SG10,CCI,7059,,ZA0,,Klimazone desTagesparameters(derzeit istTagesparameter),, + 706,Klimazone / Temperaturmessstelle,SG10,CCI,7037,00403,,,ID Klimazone /Temperaturmessstelle,, + 707,Klimazone / Temperaturmessstelle,SG10,CCI,1131,00403,,,Dienstanbieter,,[58] Wenn in diesem + 708,Klimazone / Temperaturmessstelle,SG10,CCI,3055,00403,89,,Vergeben vomHändler (hierNetzbetreiber),, + 709,Klimazone / Temperaturmessstelle,SG10,CCI,3055,,293,,"DE, BDEW(Bundesverband derEnergie- undWasserwirtschafte.V.)",, + 710,Referenzprofildaten,SG8,,,,,,,Kann,[265] Wenn im SG8 SEQ+Z01 (Daten der Marktlokation) das SG10 CCI+++ZA6 (Prognosegrundlage der Marktlokation: Prognose auf Basis von Profilen) CAV+Z36 (TEP m. Referenzmessung) vorhanden + 711,Referenzprofildaten,SG8,SEQ,,00411,,,,Muss, + 712,Referenzprofildaten,SG8,SEQ,1229,00411,Z38,,Referenzprofildaten,X, + 713,Referenz auf die ID der Marktlokation,SG8,RFF,,00413,,,,Muss, + 714,Referenz auf die ID der Marktlokation,SG8,RFF,1153,00413,Z18,,Marktlokation,X, + 715,Referenz auf die ID der Marktlokation,SG8,RFF,1154,00413,,,ID einer Marktlokation,X [950],[950] Format: Marktlokations-ID + 716,Referenzprofil,SG10,,,,,,,Muss, + 717,Referenzprofil,SG10,CCI,,00415,,,,Muss, + 718,Referenzprofil,SG10,CCI,7059,00415,Z05,,tagesparameterabhängigesEinspeiseprofil,X, + 719,Referenzprofil,SG10,CAV,,00416,,,,Muss, + 720,Referenzprofil,SG10,CAV,7111,00416,,,Code des Referenzprofils,X, + 721,Beteiligter Marktpartner MP-ID,SG12,,,,,,,,[84] Wenn SG4 STS+E01++Z35 (Status + 722,Beteiligter Marktpartner MP-ID,SG12,NAD,,00533,,,,, + 723,Beteiligter Marktpartner MP-ID,SG12,NAD,3035,00533,VY,,andere zugehörigePartei,, + 724,Beteiligter Marktpartner MP-ID,SG12,NAD,3039,00533,,,MP-ID,, + 725,Beteiligter Marktpartner MP-ID,SG12,NAD,3055,00533,9,,GS1,, + 726,Beteiligter Marktpartner MP-ID,SG12,NAD,3055,,293,,"DE, BDEW(Bundesverband derEnergie- undWasserwirtschafte.V.)",, + 727,Referenz auf die ID einer Marktlokation / Tranche,SG12,RFF,,00534,,,,, + 728,Referenz auf die ID einer Marktlokation / Tranche,SG12,RFF,1153,00534,Z18,,Marktlokation,, + 729,Referenz auf die ID einer Marktlokation / Tranche,SG12,RFF,1153,,Z20,,Tranche,, + 730,Referenz auf die ID einer Marktlokation / Tranche,SG12,RFF,1154,00534,,,ID einer Marktlokation /Tranche,,[950] Format: Marktlokations-ID + 731,Marktlokationsanschrift,SG12,,,,,,,,[170] Wenn Anschrift der Marktlokation vorhanden + 732,Marktlokationsanschrift,SG12,NAD,,00535,,,,, + 733,Marktlokationsanschrift,SG12,NAD,3035,00535,DP,,Lieferanschrift,, + 734,Marktlokationsanschrift,SG12,NAD,3124,00535,,,Zusatzinformation zurIdentifizierung,, + 735,Marktlokationsanschrift,SG12,NAD,3042,00535,,,Straße und Hausnummeroder Postfach,,"[166] Wenn vorhanden + [212] Wenn im selben SG12 NAD DE3124 nicht vorhanden" + 736,Marktlokationsanschrift,SG12,NAD,3164,00535,,,Ort,, + 737,Marktlokationsanschrift,SG12,NAD,3251,00535,,,Postleitzahl,, + 738,Marktlokationsanschrift,SG12,NAD,3207,00535,,,"Ländername, Code",, + 739,Nachrichten- Endesegment,,UNT,,00540,,,,Muss, + 740,Nachrichten- Endesegment,,UNT,0074,00540,,,Anzahl der Segmente ineiner Nachricht,X, + 741,Nachrichten- Endesegment,,UNT,0062,00540,,,Nachrichten-Referenznummer,X, + + ''' +# --- +# name: TestCli.test_kohlrahbi_cli_with_valid_arguments[55081] + ''' + ,Segmentname,Segmentgruppe,Segment,Datenelement,Segment ID,Code,Qualifier,Beschreibung,Bedingungsausdruck,Bedingung + 0,Nachrichten-Kopfsegment,,UNH,,00003,,,,Muss, + 1,Nachrichten-Kopfsegment,,UNH,0062,00003,,,Nachrichten-Referenznummer,X, + 2,Nachrichten-Kopfsegment,,UNH,0065,00003,UTILMD,,Netzanschluss-Stammdaten,X, + 3,Nachrichten-Kopfsegment,,UNH,0052,00003,D,,Entwurfs-Version,X, + 4,Nachrichten-Kopfsegment,,UNH,0054,00003,11A,,Ausgabe 2011 - A,X, + 5,Nachrichten-Kopfsegment,,UNH,0051,00003,UN,,UN/CEFACT,X, + 6,Nachrichten-Kopfsegment,,UNH,0057,00003,Versionsnummer derzugrundeliegendenBDEW-Nachrichtenbeschreibung,,S1.1a,X, + 7,Beginn der Nachricht,,BGM,,00004,,,,Muss, + 8,Beginn der Nachricht,,BGM,1001,00004,E02,,Abmeldungen,X, + 9,Beginn der Nachricht,,BGM,1004,00004,,,Dokumentennummer,X, + 10,Nachrichtendatum,,DTM,,00005,,,,Muss, + 11,Nachrichtendatum,,DTM,2005,00005,137,,Dokumenten-/Nachrichtendatum/-zeit,X, + 12,Nachrichtendatum,,DTM,2380,00005,,,"Datum oder Uhrzeit oderZeitspanne, Wert",X [931][494],"[494] Das hier genannte Datum muss der Zeitpunkt sein, zu dem das Dokument erstellt wurde, oder ein Zeitpunkt, der davor liegt + [931] Format: ZZZ = +00" + 13,Nachrichtendatum,,DTM,2379,00005,303,,CCYYMMDDHHMMZZZ,X, + 14,MP-ID Absender,SG2,,,,,,,Muss, + 15,MP-ID Absender,SG2,NAD,,00008,,,,Muss, + 16,MP-ID Absender,SG2,NAD,3035,00008,MS,,Dokumenten-/Nachrichtenausstellerbzw. -absender,X, + 17,MP-ID Absender,SG2,NAD,3039,00008,,,MP-ID,X, + 18,MP-ID Absender,SG2,NAD,3055,00008,9,,GS1,X, + 19,MP-ID Absender,SG2,NAD,3055,,293,,"DE, BDEW(Bundesverband derEnergie- undWasserwirtschaft e.V.)",X, + 20,Ansprechpartner,SG3,,,,,,,Kann, + 21,Ansprechpartner,SG3,CTA,,00009,,,,Muss, + 22,Ansprechpartner,SG3,CTA,3139,00009,IC,,Informationskontakt,X, + 23,Ansprechpartner,SG3,CTA,3412,00009,,,Name vom Ansprechpartner,X, + 24,Kommunikationsverbindung,SG3,COM,,00010,,,,Muss, + 25,Kommunikationsverbindung,SG3,COM,3148,00010,,,Nummer / Adresse,X (([939],[321] Wenn im DE3155 + 26,Kommunikationsverbindung,SG3,COM,3155,00010,EM,,Elektronische Post,X [1P0..1], + 27,Kommunikationsverbindung,SG3,COM,3155,,FX,,Telefax,X [1P0..1], + 28,Kommunikationsverbindung,SG3,COM,3155,,TE,,Telefon,X [1P0..1], + 29,Kommunikationsverbindung,SG3,COM,3155,,AJ,,weiteres Telefon,X [1P0..1], + 30,Kommunikationsverbindung,SG3,COM,3155,,AL,,Handy,X [1P0..1], + 31,MP-ID Empfänger,SG2,,,,,,,Muss, + 32,MP-ID Empfänger,SG2,NAD,,00011,,,,Muss, + 33,MP-ID Empfänger,SG2,NAD,3035,00011,MR,,Nachrichtenempfänger,X, + 34,MP-ID Empfänger,SG2,NAD,3039,00011,,,MP-ID,X [280],[280] Nur MP-ID aus Sparte Strom + 35,MP-ID Empfänger,SG2,NAD,3055,00011,9,,GS1,X, + 36,MP-ID Empfänger,SG2,NAD,3055,,293,,"DE, BDEW(Bundesverband derEnergie- undWasserwirtschaft e.V.)",X, + 37,Vorgang,SG4,,,,,,,Muss, + 38,Vorgang,SG4,IDE,,00020,,,,Muss, + 39,Vorgang,SG4,IDE,7495,00020,24,,Transaktion,X, + 40,Vorgang,SG4,IDE,7402,00020,,,Vorgangsnummer,X, + 41,Beginn zum,SG4,DTM,,00024,,,,Muss [7] ∧[577],[7] Wenn SG4 STS+7++ZG9/ZH1/ZH2 (Transaktionsgrund: Aufhebung einer zukünftigen Zuordnung wegen Auszug des Kunden / -wegen Stilllegung / -wegen + 42,Beginn zum,SG4,DTM,2005,00024,92,,Datum Vertragsbeginn,X, + 43,Beginn zum,SG4,DTM,2380,00024,,,"Datum oder Uhrzeit oderZeitspanne, Wert",X [UB1], + 44,Beginn zum,SG4,DTM,2379,00024,303,,CCYYMMDDHHMMZZZ,X, + 45,Ende zum,SG4,DTM,,00025,,,,Muss [11],[11] Wenn SG4 STS+7++ZG9/ZH1/ZH2 (Transaktionsgrund: Aufhebung einer zukünftigen Zuordnung wegen Auszug des Kunden / -wegen Stilllegung / -wegen aufgehobenem Vertragsverhältnis) nicht vorhanden + 46,Ende zum,SG4,DTM,2005,00025,93,,Datum Vertragsende,X, + 47,Ende zum,SG4,DTM,2380,00025,,,"Datum oder Uhrzeit oderZeitspanne, Wert",X [UB1], + 48,Ende zum,SG4,DTM,2379,00025,303,,CCYYMMDDHHMMZZZ,X, + 49,Bilanzierungsende,SG4,DTM,,00030,,,,,[29] Wenn eine Bilanzierung stattfindet + 50,Bilanzierungsende,SG4,DTM,2005,00030,159,,Bilanzierungsende,, + 51,Bilanzierungsende,SG4,DTM,2380,00030,,,"Datum oder Uhrzeit oderZeitspanne, Wert",, + 52,Bilanzierungsende,SG4,DTM,2379,00030,303,,CCYYMMDDHHMMZZZ,, + 53,Transaktionsgrund,SG4,STS,,00037,,,,Muss [2061],[2061] Segment bzw. Segmentgruppe ist genau einmal je SG4 IDE (Vorgang) anzugeben + 54,Transaktionsgrund,SG4,STS,9015,00037,7,,Transaktionsgrund,X, + 55,Transaktionsgrund,SG4,STS,9013,00037,E03,,Wechsel,X, + 56,Transaktionsgrund,SG4,STS,9013,,ZH2,,Aufhebung einerzukünftigen Zuordnungwegen aufgehobenemVertragsverhältnis,X, + 57,Status der Antwort,SG4,STS,,00039,,,,,[249] Innerhalb eines + 58,Status der Antwort,SG4,STS,9015,00039,E01,,Status der Antwort,, + 59,Status der Antwort,SG4,STS,9013,00039,,,Code des Prüfschritts,, + 60,Status der Antwort,SG4,STS,1131,00039,E_0306,,EBD Nr. E_0306,, + 61,Bemerkung (Feld für allgemeine Hinweise),SG4,FTX,,00043,,,,,[48] Wenn in dieser SG4 das STS+E01++E14/ A99 (Status der Antwort: Ablehnung Sonstiges) vorhanden + 62,Bemerkung (Feld für allgemeine Hinweise),SG4,FTX,4451,00043,ACB,,ZusätzlicheInformationen (fürallgemeine Hinweise),, + 63,Bemerkung (Feld für allgemeine Hinweise),SG4,FTX,4440,00043,,,Text für allgemeine Information,, + 64,Marktlokation,SG5,,,,,,,Muss [2061]∧ [348],"[348] Wenn SG5 LOC+Z21 (Tranche) nicht vorhanden + [2061] Segment bzw. Segmentgruppe ist genau einmal je SG4 IDE (Vorgang) anzugeben" + 65,Marktlokation,SG5,LOC,,00051,,,,Muss, + 66,Marktlokation,SG5,LOC,3227,00051,Z16,,Marktlokation,X, + 67,Marktlokation,SG5,LOC,3225,00051,,,ID der Marktlokation,X [950],[950] Format: Marktlokations-ID + 68,Tranche,SG5,,,,,,,Muss [2061]∧ [347],"[347] Wenn SG5 LOC+Z16 (Marktlokation) nicht vorhanden + [2061] Segment bzw. Segmentgruppe ist genau einmal je SG4 IDE (Vorgang) anzugeben" + 69,Tranche,SG5,LOC,,00054,,,,Muss, + 70,Tranche,SG5,LOC,3227,00054,Z21,,Tranche,X, + 71,Tranche,SG5,LOC,3225,00054,,,ID der Tranche,X [950],[950] Format: Marktlokations-ID + 72,Prüfidentifikator,SG6,,,,,,,Muss, + 73,Prüfidentifikator,SG6,RFF,,00057,,,,Muss, + 74,Prüfidentifikator,SG6,RFF,1153,00057,Z13,,Prüfidentifikator,X, + 75,Prüfidentifikator,SG6,RFF,1154,00057,55081,,MPES / Abmeldung,X, + 76,Prüfidentifikator,SG6,RFF,1154,,55082,,MPES / Bestätigung,, + 77,Referenz Vorgangsnummer (aus Anfragenachricht),SG6,,,,,,,, + 78,Referenz Vorgangsnummer (aus Anfragenachricht),SG6,RFF,,00058,,,,, + 79,Referenz Vorgangsnummer (aus Anfragenachricht),SG6,RFF,1153,00058,TN,,Transaktions-Referenznummer,, + 80,Referenz Vorgangsnummer (aus Anfragenachricht),SG6,RFF,1154,00058,,,Vorgangsnummer,, + 81,Daten der Marktlokation,SG8,,,,,,,Muss [2061],[2061] Segment bzw. Segmentgruppe ist genau einmal je SG4 IDE (Vorgang) anzugeben + 82,Daten der Marktlokation,SG8,SEQ,,00103,,,,Muss, + 83,Daten der Marktlokation,SG8,SEQ,1229,00103,Z01,,Daten der Marktlokation,X, + 84,Referenz auf die ID der Marktlokation,SG8,RFF,,00104,,,,Muss [25],[25] Wenn SG5 LOC+Z16 (Marktlokation) vorhanden + 85,Referenz auf die ID der Marktlokation,SG8,RFF,1153,00104,Z18,,Marktlokation,X, + 86,Referenz auf die ID der Marktlokation,SG8,RFF,1154,00104,,,ID der Marktlokation,X [950],[950] Format: Marktlokations-ID + 87,Lieferrichtung,SG10,,,,,,,Muss, + 88,Lieferrichtung,SG10,CCI,,00110,,,,Muss, + 89,Lieferrichtung,SG10,CCI,7059,00110,Z30,,Lieferrichtung,X, + 90,Lieferrichtung,SG10,CCI,7037,00110,Z06,,Erzeugung,X, + 91,Nachrichten-Endesegment,,UNT,,00540,,,,Muss, + 92,Nachrichten-Endesegment,,UNT,0074,00540,,,Anzahl der Segmente in einerNachricht,X, + 93,Nachrichten-Endesegment,,UNT,0062,00540,,,Nachrichten-Referenznummer,X, + + ''' +# --- +# name: TestCli.test_kohlrahbi_cli_with_valid_arguments[55086] + ''' + ,Segmentname,Segmentgruppe,Segment,Datenelement,Segment ID,Code,Qualifier,Beschreibung,Bedingungsausdruck,Bedingung + 0,Nachrichten-Kopfsegment,,UNH,,00003,,,,Muss, + 1,Nachrichten-Kopfsegment,,UNH,0062,00003,,,Nachrichten-Referenznummer,X, + 2,Nachrichten-Kopfsegment,,UNH,0065,00003,UTILMD,,Netzanschluss-Stammdaten,X, + 3,Nachrichten-Kopfsegment,,UNH,0052,00003,D,,Entwurfs-Version,X, + 4,Nachrichten-Kopfsegment,,UNH,0054,00003,11A,,Ausgabe 2011 - A,X, + 5,Nachrichten-Kopfsegment,,UNH,0051,00003,UN,,UN/CEFACT,X, + 6,Nachrichten-Kopfsegment,,UNH,0057,00003,Versionsnummer derzugrundeliegendenBDEW-Nachrichtenbeschreibung,,S1.1a,X, + 7,Beginn der Nachricht,,BGM,,00004,,,,Muss, + 8,Beginn der Nachricht,,BGM,1001,00004,E02,,Abmeldungen,X, + 9,Beginn der Nachricht,,BGM,1004,00004,,,Dokumentennummer,X, + 10,Nachrichtendatum,,DTM,,00005,,,,Muss, + 11,Nachrichtendatum,,DTM,2005,00005,137,,Dokumenten-/Nachrichtendatum/-zeit,X, + 12,Nachrichtendatum,,DTM,2380,00005,,,"Datum oder Uhrzeit oderZeitspanne, Wert",X [931][494],"[494] Das hier genannte Datum muss der Zeitpunkt sein, zu dem das Dokument erstellt wurde, oder ein Zeitpunkt, der davor liegt + [931] Format: ZZZ = +00" + 13,Nachrichtendatum,,DTM,2379,00005,303,,CCYYMMDDHHMMZZZ,X, + 14,MP-ID Absender,SG2,,,,,,,Muss, + 15,MP-ID Absender,SG2,NAD,,00008,,,,Muss, + 16,MP-ID Absender,SG2,NAD,3035,00008,MS,,Dokumenten-/Nachrichtenausstellerbzw. -absender,X, + 17,MP-ID Absender,SG2,NAD,3039,00008,,,MP-ID,X, + 18,MP-ID Absender,SG2,NAD,3055,00008,9,,GS1,X, + 19,MP-ID Absender,SG2,NAD,3055,,293,,"DE, BDEW(Bundesverband derEnergie- undWasserwirtschaft e.V.)",X, + 20,Ansprechpartner,SG3,,,,,,,Kann, + 21,Ansprechpartner,SG3,CTA,,00009,,,,Muss, + 22,Ansprechpartner,SG3,CTA,3139,00009,IC,,Informationskontakt,X, + 23,Ansprechpartner,SG3,CTA,3412,00009,,,Name vom Ansprechpartner,X, + 24,Kommunikationsverbindung,SG3,COM,,00010,,,,Muss, + 25,Kommunikationsverbindung,SG3,COM,3148,00010,,,Nummer / Adresse,X (([939][321]) ∨([940][322])) ∧[514],"[321] Wenn im DE3155 in demselben COM der Code EM vorhanden ist + [322] Wenn im DE3155 in demselben COM der Code TE / FX / AJ / AL vorhanden ist + [514] Hinweis: Es darf nur eine Information im DE3148 übermittelt werden + [939] Format: Die Zeichenkette muss die Zeichen @ und . enthalten + [940] Format: Die Zeichenkette muss mit dem Zeichen + beginnen und danach dürfen nur noch Ziffern folgen" + 26,Kommunikationsverbindung,SG3,COM,3155,00010,EM,,Elektronische Post,X [1P0..1], + 27,Kommunikationsverbindung,SG3,COM,3155,,FX,,Telefax,X [1P0..1], + 28,Kommunikationsverbindung,SG3,COM,3155,,TE,,Telefon,X [1P0..1], + 29,Kommunikationsverbindung,SG3,COM,3155,,AJ,,weiteres Telefon,X [1P0..1], + 30,Kommunikationsverbindung,SG3,COM,3155,,AL,,Handy,X [1P0..1], + 31,MP-ID Empfänger,SG2,,,,,,,Muss, + 32,MP-ID Empfänger,SG2,NAD,,00011,,,,Muss, + 33,MP-ID Empfänger,SG2,NAD,3035,00011,MR,,Nachrichtenempfänger,X, + 34,MP-ID Empfänger,SG2,NAD,3039,00011,,,MP-ID,X [280],[280] Nur MP-ID aus Sparte Strom + 35,MP-ID Empfänger,SG2,NAD,3055,00011,9,,GS1,X, + 36,MP-ID Empfänger,SG2,NAD,3055,,293,,"DE, BDEW(Bundesverband derEnergie- undWasserwirtschaft e.V.)",X, + 37,Vorgang,SG4,,,,,,,Muss, + 38,Vorgang,SG4,IDE,,00020,,,,Muss, + 39,Vorgang,SG4,IDE,7495,00020,24,,Transaktion,X, + 40,Vorgang,SG4,IDE,7402,00020,,,Vorgangsnummer,X, + 41,Ende zum,SG4,DTM,,00025,,,,Muss, + 42,Ende zum,SG4,DTM,2005,00025,93,,Datum Vertragsende,X, + 43,Ende zum,SG4,DTM,2380,00025,,,"Datum oder Uhrzeit oderZeitspanne, Wert",X [UB1], + 44,Ende zum,SG4,DTM,2379,00025,303,,CCYYMMDDHHMMZZZ,X, + 45,Transaktionsgrund,SG4,STS,,00037,,,,Muss [2061],[2061] Segment bzw. Segmentgruppe ist genau einmal je SG4 IDE (Vorgang) anzugeben + 46,Transaktionsgrund,SG4,STS,9015,00037,7,,Transaktionsgrund,X, + 47,Transaktionsgrund,SG4,STS,9013,00037,E03,,Wechsel,X, + 48,Status der Antwort,SG4,STS,,00039,,,,,[249] Innerhalb eines SG4 IDE müssen alle DE1131 der SG4 STS+E01 den identischen Wert enthalten + 49,Status der Antwort,SG4,STS,9015,00039,E01,,Status der Antwort,, + 50,Status der Antwort,SG4,STS,9013,00039,,,Code des Prüfschritts,, + 51,Status der Antwort,SG4,STS,1131,00039,Codeliste Strom Nr.S_0047Codeliste Strom Nr.S_0048,,S_0047S_0048,, + 52,Marktlokation,SG5,,,,,,,Muss [2061]∧ [348],"[348] Wenn SG5 LOC+Z21 (Tranche) nicht vorhanden + [2061] Segment bzw. Segmentgruppe ist genau einmal je SG4 IDE (Vorgang) anzugeben" + 53,Marktlokation,SG5,LOC,,00051,,,,Muss, + 54,Marktlokation,SG5,LOC,3227,00051,Z16,,Marktlokation,X, + 55,Marktlokation,SG5,LOC,3225,00051,,,ID der Marktlokation,X [950],[950] Format: Marktlokations-ID + 56,Tranche,SG5,,,,,,,Muss [2061]∧ [347],"[347] Wenn SG5 LOC+Z16 (Marktlokation) nicht vorhanden + [2061] Segment bzw. Segmentgruppe ist genau einmal je SG4 IDE (Vorgang) anzugeben" + 57,Tranche,SG5,LOC,,00054,,,,Muss, + 58,Tranche,SG5,LOC,3227,00054,Z21,,Tranche,X, + 59,Tranche,SG5,LOC,3225,00054,,,ID der Tranche,X [950],[950] Format: Marktlokations-ID + 60,Prüfidentifikator,SG6,,,,,,,Muss, + 61,Prüfidentifikator,SG6,RFF,,00057,,,,Muss, + 62,Prüfidentifikator,SG6,RFF,1153,00057,Z13,,Prüfidentifikator,X, + 63,Prüfidentifikator,SG6,RFF,1154,00057,55086,,MPES / Abmeldeanfragedes NB,X, + 64,Prüfidentifikator,SG6,RFF,1154,,55087,,MPES / BestätigungAbmeldeanfrage,, + 65,Prüfidentifikator,SG6,RFF,1154,,55088,,MPES / AblehnungAbmeldeanfrage,, + 66,Referenz Vorgangsnummer (aus Anfragenachricht),SG6,,,,,,,, + 67,Referenz Vorgangsnummer (aus Anfragenachricht),SG6,RFF,,00058,,,,, + 68,Referenz Vorgangsnummer (aus Anfragenachricht),SG6,RFF,1153,00058,TN,,Transaktions-Referenznummer,, + 69,Referenz Vorgangsnummer (aus Anfragenachricht),SG6,RFF,1154,00058,,,Vorgangsnummer,, + 70,Daten der Marktlokation,SG8,,,,,,,Muss [2061],[2061] Segment bzw. Segmentgruppe ist genau einmal je SG4 IDE (Vorgang) anzugeben + 71,Daten der Marktlokation,SG8,SEQ,,00103,,,,Muss, + 72,Daten der Marktlokation,SG8,SEQ,1229,00103,Z01,,Daten der Marktlokation,X, + 73,Referenz auf die ID der Marktlokation,SG8,RFF,,00104,,,,Muss, + 74,Referenz auf die ID der Marktlokation,SG8,RFF,1153,00104,Z18,,Marktlokation,X, + 75,Referenz auf die ID der Marktlokation,SG8,RFF,1154,00104,,,ID der Marktlokation,X [950],[950] Format: Marktlokations-ID + 76,Lieferrichtung,SG10,,,,,,,Muss, + 77,Lieferrichtung,SG10,CCI,,00110,,,,Muss, + 78,Lieferrichtung,SG10,CCI,7059,00110,Z30,,Lieferrichtung,X, + 79,Lieferrichtung,SG10,CCI,7037,00110,Z06,,Erzeugung,X, + 80,Beteiligter Marktpartner MP-ID,SG12,,,,,,,Muss [567],[567] Hinweis: Neulieferant + 81,Beteiligter Marktpartner MP-ID,SG12,NAD,,00533,,,,Muss, + 82,Beteiligter Marktpartner MP-ID,SG12,NAD,3035,00533,VY,,andere zugehörige Partei,X, + 83,Beteiligter Marktpartner MP-ID,SG12,NAD,3039,00533,,,MP-ID,X, + 84,Beteiligter Marktpartner MP-ID,SG12,NAD,3055,00533,9,,GS1,X, + 85,Beteiligter Marktpartner MP-ID,SG12,NAD,3055,,293,,"DE, BDEW(Bundesverband derEnergie- undWasserwirtschaft e.V.)",X, + 86,Referenz auf die ID einer Marktlokation / Tranche,SG12,RFF,,00534,,,,Muss, + 87,Referenz auf die ID einer Marktlokation / Tranche,SG12,RFF,1153,00534,Z18,,Marktlokation,X, + 88,Referenz auf die ID einer Marktlokation / Tranche,SG12,RFF,1154,00534,,,ID einer Marktlokation / Tranche,X [950],[950] Format: Marktlokations-ID + 89,Nachrichten-Endesegment,,UNT,,00540,,,,Muss, + 90,Nachrichten-Endesegment,,UNT,0074,00540,,,Anzahl der Segmente in einerNachricht,X, + 91,Nachrichten-Endesegment,,UNT,0062,00540,,,Nachrichten-Referenznummer,X, + + ''' +# --- +# name: TestCli.test_kohlrahbi_cli_with_valid_arguments[55093] + ''' + ,Segmentname,Segmentgruppe,Segment,Datenelement,Segment ID,Code,Qualifier,Beschreibung,Bedingungsausdruck,Bedingung + 0,Nachrichten-Kopfsegment,,UNH,,00003,,,,Muss, + 1,Nachrichten-Kopfsegment,,UNH,0062,00003,,,Nachrichten-Referenznummer,X, + 2,Nachrichten-Kopfsegment,,UNH,0065,00003,UTILMD,,Netzanschluss-Stammdaten,X, + 3,Nachrichten-Kopfsegment,,UNH,0052,00003,D,,Entwurfs-Version,X, + 4,Nachrichten-Kopfsegment,,UNH,0054,00003,11A,,Ausgabe 2011 - A,X, + 5,Nachrichten-Kopfsegment,,UNH,0051,00003,UN,,UN/CEFACT,X, + 6,Nachrichten-Kopfsegment,,UNH,0057,00003,Versionsnummer derzugrundeliegendenBDEW-Nachrichtenbeschreibung,,S1.1a,X, + 7,Beginn der Nachricht,,BGM,,00004,,,,Muss, + 8,Beginn der Nachricht,,BGM,1001,00004,E44,,Informationsmeldung,X, + 9,Beginn der Nachricht,,BGM,1004,00004,,,Dokumentennummer,X, + 10,Nachrichtendatum,,DTM,,00005,,,,Muss, + 11,Nachrichtendatum,,DTM,2005,00005,137,,Dokumenten-/Nachrichtendatum/-zeit,X, + 12,Nachrichtendatum,,DTM,2380,00005,,,"Datum oder Uhrzeit oderZeitspanne, Wert",X [931][494],"[494] Das hier genannte Datum muss der Zeitpunkt sein, zu dem das Dokument erstellt wurde, oder ein Zeitpunkt, der davor liegt + [931] Format: ZZZ = +00" + 13,Nachrichtendatum,,DTM,2379,00005,303,,CCYYMMDDHHMMZZZ,X, + 14,MP-ID Absender,SG2,,,,,,,Muss, + 15,MP-ID Absender,SG2,NAD,,00008,,,,Muss, + 16,MP-ID Absender,SG2,NAD,3035,00008,MS,,Dokumenten-/Nachrichtenausstellerbzw. -absender,X, + 17,MP-ID Absender,SG2,NAD,3039,00008,,,MP-ID,X, + 18,MP-ID Absender,SG2,NAD,3055,00008,9,,GS1,X, + 19,MP-ID Absender,SG2,NAD,3055,,293,,"DE, BDEW(Bundesverband derEnergie- undWasserwirtschaft e.V.)",X, + 20,Ansprechpartner,SG3,,,,,,,Kann, + 21,Ansprechpartner,SG3,CTA,,00009,,,,Muss, + 22,Ansprechpartner,SG3,CTA,3139,00009,IC,,Informationskontakt,X, + 23,Ansprechpartner,SG3,CTA,3412,00009,,,Name vom Ansprechpartner,X, + 24,Kommunikationsverbindung,SG3,COM,,00010,,,,Muss, + 25,Kommunikationsverbindung,SG3,COM,3148,00010,,,Nummer / Adresse,X (([939][321]) ∨([940][322])) ∧[514],"[321] Wenn im DE3155 in demselben COM der Code EM vorhanden ist + [322] Wenn im DE3155 in demselben COM der Code TE / FX / AJ / AL vorhanden ist + [514] Hinweis: Es darf nur eine Information im DE3148 übermittelt werden + [939] Format: Die Zeichenkette muss die Zeichen @ und . enthalten + [940] Format: Die Zeichenkette muss mit dem Zeichen + beginnen und danach dürfen nur noch Ziffern folgen" + 26,Kommunikationsverbindung,SG3,COM,3155,00010,EM,,Elektronische Post,X [1P0..1], + 27,Kommunikationsverbindung,SG3,COM,3155,,FX,,Telefax,X [1P0..1], + 28,Kommunikationsverbindung,SG3,COM,3155,,TE,,Telefon,X [1P0..1], + 29,Kommunikationsverbindung,SG3,COM,3155,,AJ,,weiteres Telefon,X [1P0..1], + 30,Kommunikationsverbindung,SG3,COM,3155,,AL,,Handy,X [1P0..1], + 31,MP-ID Empfänger,SG2,,,,,,,Muss, + 32,MP-ID Empfänger,SG2,NAD,,00011,,,,Muss, + 33,MP-ID Empfänger,SG2,NAD,3035,00011,MR,,Nachrichtenempfänger,X, + 34,MP-ID Empfänger,SG2,NAD,3039,00011,,,MP-ID,X [280],[280] Nur MP-ID aus Sparte Strom + 35,MP-ID Empfänger,SG2,NAD,3055,00011,9,,GS1,X, + 36,MP-ID Empfänger,SG2,NAD,3055,,293,,"DE, BDEW(Bundesverband derEnergie- undWasserwirtschaft e.V.)",X, + 37,Vorgang,SG4,,,,,,,Muss, + 38,Vorgang,SG4,IDE,,00020,,,,Muss, + 39,Vorgang,SG4,IDE,7495,00020,24,,Transaktion,X, + 40,Vorgang,SG4,IDE,7402,00020,,,Vorgangsnummer,X, + 41,Beginn zum,SG4,DTM,,00024,,,,,[507] Hinweis: Ursprünglich vom NB bestätigtes Beginndatum + 42,Beginn zum,SG4,DTM,2005,00024,92,,Datum Vertragsbeginn,, + 43,Beginn zum,SG4,DTM,2380,00024,,,"Datum oder Uhrzeit oderZeitspanne, Wert",, + 44,Beginn zum,SG4,DTM,2379,00024,303,,CCYYMMDDHHMMZZZ,, + 45,Ende zum,SG4,DTM,,00025,,,,Muss, + 46,Ende zum,SG4,DTM,2005,00025,93,,Datum Vertragsende,X, + 47,Ende zum,SG4,DTM,2380,00025,,,"Datum oder Uhrzeit oderZeitspanne, Wert",X [UB1], + 48,Ende zum,SG4,DTM,2379,00025,303,,CCYYMMDDHHMMZZZ,X, + 49,Bilanzierungsende,SG4,DTM,,00030,,,,Soll [29],[29] Wenn eine Bilanzierung stattfindet + 50,Bilanzierungsende,SG4,DTM,2005,00030,159,,Bilanzierungsende,X, + 51,Bilanzierungsende,SG4,DTM,2380,00030,,,"Datum oder Uhrzeit oderZeitspanne, Wert",X [UB1], + 52,Bilanzierungsende,SG4,DTM,2379,00030,303,,CCYYMMDDHHMMZZZ,X, + 53,Transaktionsgrund,SG4,STS,,00037,,,,Muss [2061],[2061] Segment bzw. Segmentgruppe ist genau einmal je SG4 IDE (Vorgang) anzugeben + 54,Transaktionsgrund,SG4,STS,9015,00037,7,,Transaktionsgrund,X, + 55,Transaktionsgrund,SG4,STS,9013,00037,Z26,,Information überexistierende Zuordnung,, + 56,Transaktionsgrund,SG4,STS,9013,,ZC8,,Beendigung derZuordnung,X, + 57,Transaktionsgrund,SG4,STS,9013,,ZH0,,Aufhebung einerzukünftigen Zuordnungwegen Anmeldung einesanderen Lieferanten zueinem früheren Termin,, + 58,Transaktionsgrund,SG4,STS,9013,,ZH1,,Aufhebung einerzukünftigen Zuordnungwegen Stilllegung,, + 59,Transaktionsgrund,SG4,STS,9013,,ZD9,,Beendigung wegenRückzuordnungsmeldung,X, + 60,Transaktionsgrund,SG4,STS,9013,,ZG5,,Aufhebung einerzukünftigen Zuordnungaufgrund §38 EEG 2014bzw. § 21b Abs. 1 Nr. 2EEG 2017,, + 61,Transaktionsgrund,SG4,STS,9013,,ZG6,,Beendigung der,X, + 62,Marktlokation,SG5,,,,,,,Muss [2061]∧ [348],"[348] Wenn SG5 LOC+Z21 (Tranche) nicht vorhanden + [2061] Segment bzw. Segmentgruppe ist genau einmal je SG4 IDE (Vorgang) anzugeben" + 63,Marktlokation,SG5,LOC,,00051,,,,Muss, + 64,Marktlokation,SG5,LOC,3227,00051,Z16,,Marktlokation,X, + 65,Marktlokation,SG5,LOC,3225,00051,,,ID der Marktlokation,X [950],[950] Format: Marktlokations-ID + 66,Tranche,SG5,,,,,,,Muss [2061]∧ [347],"[347] Wenn SG5 LOC+Z16 (Marktlokation) nicht vorhanden + [2061] Segment bzw. Segmentgruppe ist genau einmal je SG4 IDE (Vorgang) anzugeben" + 67,Tranche,SG5,LOC,,00054,,,,Muss, + 68,Tranche,SG5,LOC,3227,00054,Z21,,Tranche,X, + 69,Tranche,SG5,LOC,3225,00054,,,ID der Tranche,X [950],[950] Format: Marktlokations-ID + 70,Prüfidentifikator,SG6,,,,,,,Muss, + 71,Prüfidentifikator,SG6,RFF,,00057,,,,Muss, + 72,Prüfidentifikator,SG6,RFF,1153,00057,Z13,,Prüfidentifikator,X, + 73,Prüfidentifikator,SG6,RFF,1154,00057,55092,,MPES /Informationsmeldungüber existierendeZuordnung,, + 74,Prüfidentifikator,SG6,RFF,1154,,55093,,MPES /Informationsmeldung zurBeendigung derZuordnung,X, + 75,Prüfidentifikator,SG6,RFF,1154,,55094,,MPES /Informationsmeldung zurAufhebung einer zuk.Zuordnung,, + 76,Referenz Vorgangsnummer (aus Anfragenachricht),SG6,,,,,,,, + 77,Referenz Vorgangsnummer (aus Anfragenachricht),SG6,RFF,,00058,,,,, + 78,Referenz Vorgangsnummer (aus Anfragenachricht),SG6,RFF,1153,00058,TN,,Transaktions-,, + 79,Referenz Vorgangsnummer (aus Anfragenachricht),SG6,RFF,1154,00058,,,Vorgangsnummer,, + 80,Daten der Marktlokation,SG8,,,,,,,Muss [2061],[2061] Segment bzw. Segmentgruppe ist genau einmal je SG4 IDE (Vorgang) anzugeben + 81,Daten der Marktlokation,SG8,SEQ,,00103,,,,Muss, + 82,Daten der Marktlokation,SG8,SEQ,1229,00103,Z01,,Daten der Marktlokation,X, + 83,Referenz auf die ID der Marktlokation,SG8,RFF,,00104,,,,Muss, + 84,Referenz auf die ID der Marktlokation,SG8,RFF,1153,00104,Z18,,Marktlokation,X, + 85,Referenz auf die ID der Marktlokation,SG8,RFF,1154,00104,,,ID der Marktlokation,X [950],[950] Format: Marktlokations-ID + 86,Lieferrichtung,SG10,,,,,,,Muss, + 87,Lieferrichtung,SG10,CCI,,00110,,,,Muss, + 88,Lieferrichtung,SG10,CCI,7059,00110,Z30,,Lieferrichtung,X, + 89,Lieferrichtung,SG10,CCI,7037,00110,Z06,,Erzeugung,X, + 90,Beteiligter Marktpartner MP-ID,SG12,,,,,,,,"[206] Wenn SG4 STS+7++ZG5 (Transaktionsgrund: Aufhebung der zukünftigen Zuordnung aufgrund §38 EEG 2014 bzw. §21b Abs. 1 Nr. 2 EEG 2017) nicht vorhanden + [518] Hinweis: Es sind alle Altlieferanten anzugeben, an die eine Abmeldeanfrage gesendet wird + [566] Hinweis: Altlieferant + [579] Hinweis: Auslösender Marktpartner (LFN bei STS+7++ZH0, NB bei STS+7++ZH1)" + 91,Beteiligter Marktpartner MP-ID,SG12,NAD,,00533,,,,, + 92,Beteiligter Marktpartner MP-ID,SG12,NAD,3035,00533,VY,,andere zugehörige Partei,, + 93,Beteiligter Marktpartner MP-ID,SG12,NAD,3039,00533,,,MP-ID,, + 94,Beteiligter Marktpartner MP-ID,SG12,NAD,3055,00533,9,,GS1,, + 95,Beteiligter Marktpartner MP-ID,SG12,NAD,3055,,293,,"DE, BDEW(Bundesverband derEnergie- undWasserwirtschaft e.V.)",, + 96,Referenz auf die ID einer Marktlokation / Tranche,SG12,RFF,,00534,,,,, + 97,Referenz auf die ID einer Marktlokation / Tranche,SG12,RFF,1153,00534,Z18,,Marktlokation,, + 98,Referenz auf die ID einer Marktlokation / Tranche,SG12,RFF,1153,,Z20,,Tranche,, + 99,Referenz auf die ID einer Marktlokation / Tranche,SG12,RFF,1154,00534,,,ID einer Marktlokation / Tranche,,[950] Format: Marktlokations-ID + 100,Nachrichten-Endesegment,,UNT,,00540,,,,Muss, + 101,Nachrichten-Endesegment,,UNT,0074,00540,,,Anzahl der Segmente in einerNachricht,X, + 102,Nachrichten-Endesegment,,UNT,0062,00540,,,Nachrichten-Referenznummer,X, + + ''' +# --- +# name: TestCli.test_kohlrahbi_cli_with_valid_arguments[55105] + ''' + ,Segmentname,Segmentgruppe,Segment,Datenelement,Segment ID,Code,Qualifier,Beschreibung,Bedingungsausdruck,Bedingung + 0,Nachrichten-Kopfsegment,,UNH,,00003,,,,Muss, + 1,Nachrichten-Kopfsegment,,UNH,0062,00003,,,Nachrichten-Referenznummer,X, + 2,Nachrichten-Kopfsegment,,UNH,0065,00003,UTILMD,,Netzanschluss-Stammdaten,X, + 3,Nachrichten-Kopfsegment,,UNH,0052,00003,D,,Entwurfs-Version,X, + 4,Nachrichten-Kopfsegment,,UNH,0054,00003,11A,,Ausgabe 2011 - A,X, + 5,Nachrichten-Kopfsegment,,UNH,0051,00003,UN,,UN/CEFACT,X, + 6,Nachrichten-Kopfsegment,,UNH,0057,00003,Versionsnummer derzugrundeliegendenBDEW-Nachrichtenbeschreibung,,S1.1a,X, + 7,Nachrichten-Kopfsegment,,UNH,0068,00003,,,Allgemeine Zuordnungs-Referenz,,[1] Wenn Aufteilung vorhanden + 8,Nachrichten-Kopfsegment,,UNH,0070,00003,,,Übermittlungsfolgenummer,,[252] Wenn DE0068 vorhanden + 9,Nachrichten-Kopfsegment,,UNH,0073,00003,C,,Beginn,, + 10,Nachrichten-Kopfsegment,,UNH,0073,,F,,Ende,,"[2] Wenn UNH DE0070 (Übermittlungsfolgenum mer) mit 1 vorhanden + [3] Bei Aufteilung, in der Nachricht mit der höchsten Übermittlungsfolgenum mer" + 11,Beginn der Nachricht,,BGM,,00004,,,,Muss, + 12,Beginn der Nachricht,,BGM,1001,00004,Z22,,Netzbetreiberwechsel,X, + 13,Beginn der Nachricht,,BGM,1004,00004,,,Dokumentennummer,X, + 14,Nachrichtendatum,,DTM,,00005,,,,Muss, + 15,Nachrichtendatum,,DTM,2005,00005,137,,Dokumenten-/Nachrichtendatum/-zeit,X, + 16,Nachrichtendatum,,DTM,2380,00005,,,"Datum oder Uhrzeit oderZeitspanne, Wert",X [931][494],"[494] Das hier genannte Datum muss der Zeitpunkt sein, zu dem das Dokument erstellt wurde, oder ein Zeitpunkt, der davor liegt + [931] Format: ZZZ = +00" + 17,Nachrichtendatum,,DTM,2379,00005,303,,CCYYMMDDHHMMZZZ,X, + 18,MP-ID Absender,SG2,,,,,,,Muss, + 19,MP-ID Absender,SG2,NAD,,00008,,,,Muss, + 20,MP-ID Absender,SG2,NAD,3035,00008,MS,,Dokumenten-/Nachrichtenaussteller,X, + 21,MP-ID Absender,SG2,NAD,3039,00008,,,MP-ID,X, + 22,MP-ID Absender,SG2,NAD,3055,00008,9,,GS1,X, + 23,MP-ID Absender,SG2,NAD,3055,,293,,"DE, BDEW(Bundesverband derEnergie- undWasserwirtschaft e.V.)",X, + 24,Ansprechpartner,SG3,,,,,,,Kann, + 25,Ansprechpartner,SG3,CTA,,00009,,,,Muss, + 26,Ansprechpartner,SG3,CTA,3139,00009,IC,,Informationskontakt,X, + 27,Ansprechpartner,SG3,CTA,3412,00009,,,Name vom Ansprechpartner,X, + 28,Kommunikationsverbindung,SG3,COM,,00010,,,,Muss, + 29,Kommunikationsverbindung,SG3,COM,3148,00010,,,Nummer / Adresse,X (([939][321]) ∨([940][322])) ∧[514],"[321] Wenn im DE3155 in demselben COM der Code EM vorhanden ist + [322] Wenn im DE3155 in demselben COM der Code TE / FX / AJ / AL vorhanden ist + [514] Hinweis: Es darf nur eine Information im DE3148 übermittelt werden + [939] Format: Die Zeichenkette muss die Zeichen @ und . enthalten + [940] Format: Die Zeichenkette muss mit dem Zeichen + beginnen und danach dürfen nur noch Ziffern folgen" + 30,Kommunikationsverbindung,SG3,COM,3155,00010,EM,,Elektronische Post,X [1P0..1], + 31,Kommunikationsverbindung,SG3,COM,3155,,FX,,Telefax,X [1P0..1], + 32,Kommunikationsverbindung,SG3,COM,3155,,TE,,Telefon,X [1P0..1], + 33,Kommunikationsverbindung,SG3,COM,3155,,AJ,,weiteres Telefon,X [1P0..1], + 34,Kommunikationsverbindung,SG3,COM,3155,,AL,,Handy,X [1P0..1], + 35,MP-ID Empfänger,SG2,,,,,,,Muss, + 36,MP-ID Empfänger,SG2,NAD,,00011,,,,Muss, + 37,MP-ID Empfänger,SG2,NAD,3035,00011,MR,,Nachrichtenempfänger,X, + 38,MP-ID Empfänger,SG2,NAD,3039,00011,,,MP-ID,X, + 39,MP-ID Empfänger,SG2,NAD,3055,00011,9,,GS1,X, + 40,MP-ID Empfänger,SG2,NAD,3055,,293,,"DE, BDEW(Bundesverband derEnergie- undWasserwirtschaft e.V.)",X, + 41,Vorgang,SG4,,,,,,,Muss , + 42,Vorgang,SG4,IDE,,00020,,,,Muss, + 43,Vorgang,SG4,IDE,7495,00020,24,,Transaktion,X, + 44,Vorgang,SG4,IDE,7402,00020,,,Vorgangsnummer,X, + 45,Beginn zum,SG4,DTM,,00024,,,,,"[9] Wenn SG4 STS+7++ZE4 (Transaktionsgrund: Weggefallene Markt- bzw. Messlokation) nicht vorhanden + [508] Hinweis: Beginndatum beim neuen NB" + 46,Beginn zum,SG4,DTM,2005,00024,92,,Datum Vertragsbeginn,, + 47,Beginn zum,SG4,DTM,2380,00024,,,"Datum oder Uhrzeit oderZeitspanne, Wert",, + 48,Beginn zum,SG4,DTM,2379,00024,303,,CCYYMMDDHHMMZZZ,, + 49,Ende zum,SG4,DTM,,00025,,,,,"[9] Wenn SG4 STS+7++ZE4 (Transaktionsgrund: Weggefallene Markt- bzw. Messlokation) nicht vorhanden + [14] Wenn Datum bekannt" + 50,Ende zum,SG4,DTM,2005,00025,93,,Datum Vertragsende,, + 51,Ende zum,SG4,DTM,2380,00025,,,"Datum oder Uhrzeit oderZeitspanne, Wert",, + 52,Ende zum,SG4,DTM,2379,00025,303,,CCYYMMDDHHMMZZZ,, + 53,"Änderung zum, Gültigkeit, Beginndatum",SG4,DTM,,00027,,,,Muss,[9] Wenn SG4 STS+7++ZE4 (Transaktionsgrund: Weggefallene Markt- + 54,"Änderung zum, Gültigkeit, Beginndatum",SG4,DTM,2005,00027,157,,"Gültigkeit, Beginndatum",X, + 55,"Änderung zum, Gültigkeit, Beginndatum",SG4,DTM,2380,00027,,,"Datum oder Uhrzeit oderZeitspanne, Wert",X [UB1], + 56,"Änderung zum, Gültigkeit, Beginndatum",SG4,DTM,2379,00027,303,,CCYYMMDDHHMMZZZ,X, + 57,Bilanzierungsbeginn,SG4,DTM,,00029,,,,,[9] Wenn SG4 STS+7++ZE4 (Transaktionsgrund: Weggefallene Markt- bzw. Messlokation) nicht vorhanden + 58,Bilanzierungsbeginn,SG4,DTM,2005,00029,158,,Bilanzierungsbeginn,, + 59,Bilanzierungsbeginn,SG4,DTM,2380,00029,,,"Datum oder Uhrzeit oderZeitspanne, Wert",, + 60,Bilanzierungsbeginn,SG4,DTM,2379,00029,303,,CCYYMMDDHHMMZZZ,, + 61,Bilanzierungsende,SG4,DTM,,00030,,,,,"[9] Wenn SG4 STS+7++ZE4 (Transaktionsgrund: Weggefallene Markt- bzw. Messlokation) nicht vorhanden + [28] Wenn SG4 DTM+93 (Ende zum) vorhanden + [64] Wenn SG4 DTM+158 (Bilanzierungsbeginn) vorhanden" + 62,Bilanzierungsende,SG4,DTM,2005,00030,159,,Bilanzierungsende,, + 63,Bilanzierungsende,SG4,DTM,2380,00030,,,"Datum oder Uhrzeit oderZeitspanne, Wert",, + 64,Bilanzierungsende,SG4,DTM,2379,00030,303,,CCYYMMDDHHMMZZZ,, + 65,Transaktionsgrund,SG4,STS,,00037,,,,Muss [2061],[2061] Segment bzw. Segmentgruppe ist genau einmal je SG4 IDE (Vorgang) anzugeben + 66,Transaktionsgrund,SG4,STS,9015,00037,7,,Transaktionsgrund,X, + 67,Transaktionsgrund,SG4,STS,9013,00037,Z15,,Zusätzlicher Datensatz,X, + 68,Transaktionsgrund,SG4,STS,9013,,ZE3,,Stammdatenänderung,X, + 69,Transaktionsgrund,SG4,STS,9013,,ZE4,,Weggefallene Markt-,X, + 70,Status der Antwort,SG4,STS,,00039,,,,Muss [249],[249] Innerhalb eines SG4 IDE müssen alle DE1131 der SG4 STS+E01 den identischen Wert enthalten + 71,Status der Antwort,SG4,STS,9015,00039,E01,,Status der Antwort,X, + 72,Status der Antwort,SG4,STS,9013,00039,,,Code des Prüfschritts,X, + 73,Status der Antwort,SG4,STS,1131,00039,Codeliste Gas und StromNr. GS_001,,GS_001,X, + 74,Bilanzkreiszuordnung zur Marktlokation bzw. Tranche,SG4,STS,,00041,,,,,[9] Wenn SG4 STS+7++ZE4 (Transaktionsgrund: Weggefallene Markt- bzw. Messlokation) nicht vorhanden + 75,Bilanzkreiszuordnung zur Marktlokation bzw. Tranche,SG4,STS,9015,00041,Z18,,Bilanzkreiszuordnung zurMarktlokation,, + 76,Bilanzkreiszuordnung zur Marktlokation bzw. Tranche,SG4,STS,4405,00041,Z13,,gescheitert,, + 77,Bilanzkreiszuordnung zur Marktlokation bzw. Tranche,SG4,STS,4405,,Z14,,erfolgreich,, + 78,Netzlokation,SG5,,,,,,,,[46] Wenn ID für Objekt vergeben wurde + 79,Netzlokation,SG5,LOC,,00050,,,,, + 80,Netzlokation,SG5,LOC,3227,00050,Z18,,Netzlokation,, + 81,Netzlokation,SG5,LOC,3225,00050,,,ID der Netzlokation,,[960] Format: Netzlokations-ID + 82,Marktlokation,SG5,,,,,,,Muss [2061],[2061] Segment bzw. Segmentgruppe ist genau einmal je SG4 IDE (Vorgang) anzugeben + 83,Marktlokation,SG5,LOC,,00051,,,,Muss, + 84,Marktlokation,SG5,LOC,3227,00051,Z16,,Marktlokation,X, + 85,Marktlokation,SG5,LOC,3225,00051,,,ID der Marktlokation,X [950],[950] Format: Marktlokations-ID + 86,Prüfidentifikator,SG6,,,,,,,Muss, + 87,Prüfidentifikator,SG6,RFF,,00057,,,,Muss, + 88,Prüfidentifikator,SG6,RFF,1153,00057,Z13,,Prüfidentifikator,X, + 89,Prüfidentifikator,SG6,RFF,1154,00057,55103,,NBW Strom /Stammdaten zurverbrauchendenMarktlokation,, + 90,Prüfidentifikator,SG6,RFF,1154,,55104,,NBW Strom /AktualisierteStammdaten zurverbrauchendenMarktlokation,, + 91,Prüfidentifikator,SG6,RFF,1154,,55105,,NBW Strom / Ablehnungauf Stammdaten zurverbrauchendenMarktlokation,X, + 92,Referenz Vorgangsnummer (aus Anfragenachricht),SG6,,,,,,,Muss, + 93,Referenz Vorgangsnummer (aus Anfragenachricht),SG6,RFF,,00058,,,,Muss, + 94,Referenz Vorgangsnummer (aus Anfragenachricht),SG6,RFF,1153,00058,TN,,Transaktions-Referenznummer,X, + 95,Referenz Vorgangsnummer (aus Anfragenachricht),SG6,RFF,1154,00058,,,Vorgangsnummer,X, + 96,Daten der Marktlokation,SG8,,,,,,,,"[9] Wenn SG4 STS+7++ZE4 (Transaktionsgrund: Weggefallene Markt- bzw. Messlokation) nicht vorhanden + [2061] Segment bzw. Segmentgruppe ist genau einmal je SG4 IDE (Vorgang) anzugeben" + 97,Daten der Marktlokation,SG8,SEQ,,00103,,,,, + 98,Daten der Marktlokation,SG8,SEQ,1229,00103,Z01,,Daten der Marktlokation,, + 99,Referenz auf die ID der Marktlokation,SG8,RFF,,00104,,,,, + 100,Referenz auf die ID der Marktlokation,SG8,RFF,1153,00104,Z18,,Marktlokation,, + 101,Referenz auf die ID der Marktlokation,SG8,RFF,1154,00104,,,ID der Marktlokation,,[950] Format: Marktlokations-ID + 102,Arbeit / Leistung für tagesparameterabhängige Marktlokation,SG9,,,,,,,,[4] Wenn MP-ID in SG2 NAD+MR (Nachrichtenempfänger) in der Rolle LF + 103,Arbeit / Leistung für tagesparameterabhängige Marktlokation,SG9,QTY,,00105,,,,, + 104,Arbeit / Leistung für tagesparameterabhängige Marktlokation,SG9,QTY,6063,00105,265,,VeranschlagteJahresmenge Gesamt/Jahresverbrauchsprognose für spezifische Arbeitfürtagesparameterabhängige Marktlokation,, + 105,Arbeit / Leistung für tagesparameterabhängige Marktlokation,SG9,QTY,6063,,Z08,,"Angepasste elektrischeArbeit nach Anhang Dder VDN-Richtlinie""Lastprofile fürunterbrechbareVerbrauchseinrichtungen""",, + 106,Arbeit / Leistung für tagesparameterabhängige Marktlokation,SG9,QTY,6060,00105,,,Menge,,[902] Format: Möglicher Wert: ≥ 0 + 107,Arbeit / Leistung für tagesparameterabhängige Marktlokation,SG9,QTY,6411,00105,Z16,,kWh/K (Kilowatt-Stunde/Kelvin),, + 108,Arbeit / Leistung für tagesparameterabhängige Marktlokation,SG9,QTY,6411,,KWH,,Kilowattstunde,,"[103] Wenn SG9 QTY+265 (Arbeit / Leistung für tagesparameterabhängig e Marktlokation: Veranschlagte Jahresmenge Gesamt) in dieser SG8 vorhanden + [104] Wenn SG9 QTY+Z08 (Arbeit / Leistung für tagesparameterabhängig e Marktlokation: angepasste elektrische Arbeit nach Anhang D) in dieser SG8 vorhanden" + 109,Veranschlagte Jahresmenge gesamt,SG9,,,,,,,,[106] Wenn in dieser SG8 + 110,Veranschlagte Jahresmenge gesamt,SG9,QTY,,00106,,,,, + 111,Veranschlagte Jahresmenge gesamt,SG9,QTY,6063,00106,31,,VeranschlagteJahresmenge Gesamt,, + 112,Veranschlagte Jahresmenge gesamt,SG9,QTY,6060,00106,,,Mengenangabe,,"[902] Format: Möglicher Wert: ≥ 0 + [937] Format: keine Nachkommastelle" + 113,Veranschlagte Jahresmenge gesamt,SG9,QTY,6411,00106,KWH,,Kilowattstunde,, + 114,Lieferrichtung,SG10,,,,,,,, + 115,Lieferrichtung,SG10,CCI,,00110,,,,, + 116,Lieferrichtung,SG10,CCI,7059,00110,Z30,,Lieferrichtung,, + 117,Lieferrichtung,SG10,CCI,7037,00110,Z07,,Verbrauch,, + 118,Zugeordnete Marktpartner,SG10,,,,,,,, + 119,Zugeordnete Marktpartner,SG10,CCI,,00111,,,,, + 120,Zugeordnete Marktpartner,SG10,CCI,7037,00111,ZB3,,ZugeordneterMarktpartner,, + 121,Lieferant,SG10,CAV,,00113,,,,, + 122,Lieferant,SG10,CAV,7111,00113,Z89,,LF,, + 123,Lieferant,SG10,CAV,1131,00113,,,MP-ID,, + 124,Bilanzierungsgebiet,SG10,,,,,,,, + 125,Bilanzierungsgebiet,SG10,CCI,,00118,,,,, + 126,Bilanzierungsgebiet,SG10,CCI,7059,00118,Z20,,Bilanzierungsgebiet,, + 127,Bilanzierungsgebiet,SG10,CCI,7037,00118,,,Bilanzierungsgebiet,, + 128,Zeitreihentyp,SG10,,,,,,,,[90] Wenn SG10 CCI+++ZA6 (Prognosegrundlage der Marktlokation: Prognose auf Basis von Profilen) einmal mit CAV+E14 (TLP/TEP) und einmal mit CAV+E02 (SLP/SEP) in dieser SG8 vorhanden + 129,Zeitreihentyp,SG10,CCI,,00121,,,,, + 130,Zeitreihentyp,SG10,CCI,7059,00121,15,,Struktur,, + 131,Zeitreihentyp,SG10,CCI,7037,00121,Z21,,Summenzeitreihentyp,, + 132,Zeitreihentyp,SG10,CAV,,00122,,,,, + 133,Zeitreihentyp,SG10,CAV,7111,00122,,,Code des Zeitreihentyps,, + 134,Bereits ausgetauschte Aggregationsverantwortung in MaBiS,SG10,,,,,,,, + 135,Bereits ausgetauschte Aggregationsverantwortung in MaBiS,SG10,CCI,,00129,,,,, + 136,Bereits ausgetauschte Aggregationsverantwortung in MaBiS,SG10,CCI,7059,00129,Z31,,Bereits ausgetauschteAggregationsverantwortung in MaBiS,, + 137,Bereits ausgetauschte Aggregationsverantwortung in MaBiS,SG10,CCI,7037,00129,ZA8,,NB,, + 138,Bereits ausgetauschte Aggregationsverantwortung in MaBiS,SG10,CCI,7037,,ZA9,,ÜNB,, + 139,Prognosegrundlage der Marktlokation,SG10,,,,,,,, + 140,Prognosegrundlage der Marktlokation,SG10,CCI,,00130,,,,, + 141,Prognosegrundlage der Marktlokation,SG10,CCI,7037,00130,ZC0,,Prognose auf Basis vonWerten,, + 142,Prognosegrundlage der Marktlokation,SG10,CCI,7037,,ZA6,,Prognose auf Basis vonProfilen,, + 143,Details der Prognosegrundlage,SG10,CAV,,00131,,,,,"[21] Wenn SG10 CCI+++ZA6 (Prognose auf Basis von Profilen) in dieser SG8 vorhanden + [90] Wenn SG10 CCI+++ZA6 (Prognosegrundlage der Marktlokation: Prognose auf Basis von Profilen) einmal mit CAV+E14 (TLP/TEP) und einmal" + 144,Details der Prognosegrundlage,SG10,CAV,7111,00131,E02,,SLP/SEP,, + 145,Details der Prognosegrundlage,SG10,CAV,7111,,E14,,TLP/TEP,, + 146,Profildaten,SG8,,,,,,,,"[9] Wenn SG4 STS+7++ZE4 (Transaktionsgrund: Weggefallene Markt- bzw. Messlokation) nicht vorhanden + [119] Wenn in der SG8 SEQ+Z01 SG10 CCI+++ZA6 (Prognosegrundlage der Marktlokation: Prognose auf Basis von Profilen) CAV+E02 (SLP/SEP) vorhanden" + 147,Profildaten,SG8,SEQ,,00376,,,,, + 148,Profildaten,SG8,SEQ,1229,00376,Z21,,Profildaten,, + 149,Referenz auf die ID der Marktlokation,SG8,RFF,,00378,,,,, + 150,Referenz auf die ID der Marktlokation,SG8,RFF,1153,00378,Z18,,Marktlokation,, + 151,Referenz auf die ID der Marktlokation,SG8,RFF,1154,00378,,,ID einer Marktlokation,,[950] Format: Marktlokations-ID + 152,Normiertes Profil,SG10,,,,,,,, + 153,Normiertes Profil,SG10,CCI,,00380,,,,, + 154,Normiertes Profil,SG10,CCI,7059,00380,Z02,,Standardlastprofil,, + 155,Normiertes Profil,SG10,CCI,7037,00380,E01,,synthetisches Verfahren,, + 156,Normiertes Profil,SG10,CCI,7037,,Z10,,analytisches Verfahren,,[148] Möglich wenn SG10 CCI+Z31++ZA9 (bereits ausg. Aggreg. + 157,Normiertes Profil,SG10,CAV,,00381,,,,, + 158,Normiertes Profil,SG10,CAV,7111,00381,,,Code des Normierten Profils,, + 159,Profilschardaten,SG8,,,,,,,,"[4] Wenn MP-ID in SG2 NAD+MR (Nachrichtenempfänger) in der Rolle LF + [9] Wenn SG4 STS+7++ZE4 (Transaktionsgrund: Weggefallene Markt- bzw. Messlokation) nicht vorhanden + [89] Wenn im SG8 SEQ+Z01 (Daten der Marktlokation) das SG10 CCI+++ZA6 (Prognosegrundlage der Marktlokation: Prognose auf Basis von Profilen) CAV+E14 (TLP/TEP) vorhanden + [145] Wenn SG10 CCI+Z31++ZA8 (bereits ausg. Aggreg.verantw. in MaBiS: NB) vorhanden" + 160,Profilschardaten,SG8,SEQ,,00387,,,,, + 161,Profilschardaten,SG8,SEQ,1229,00387,Z08,,Profilschardaten,, + 162,Referenz auf die ID der Marktlokation,SG8,RFF,,00389,,,,, + 163,Referenz auf die ID der Marktlokation,SG8,RFF,1153,00389,Z18,,Marktlokation,, + 164,Referenz auf die ID der Marktlokation,SG8,RFF,1154,00389,,,ID einer Marktlokation,,[950] Format: Marktlokations-ID + 165,Profilschar,SG10,,,,,,,, + 166,Profilschar,SG10,CCI,,00397,,,,, + 167,Profilschar,SG10,CCI,7037,00397,Z12,,Profilschar,, + 168,Profilschar,SG10,CAV,,00398,,,,, + 169,Profilschar,SG10,CAV,7111,00398,,,Code der Profilschar,, + 170,Normiertes Profil,SG10,,,,,,,, + 171,Normiertes Profil,SG10,CCI,,00399,,,,, + 172,Normiertes Profil,SG10,CCI,7059,00399,Z03,,tagesparameterabhängiges Lastprofil,, + 173,Normiertes Profil,SG10,CCI,7037,00399,E01,,synthetisches Verfahren,, + 174,Normiertes Profil,SG10,CCI,7037,,Z10,,analytisches Verfahren,, + 175,Normiertes Profil,SG10,CAV,,00400,,,,, + 176,Normiertes Profil,SG10,CAV,7111,00400,,,Code des Normierten Profils,, + 177,Klimazone / Temperaturmessstelle,SG10,,,,,,,, + 178,Klimazone / Temperaturmessstelle,SG10,CCI,,00403,,,,, + 179,Klimazone / Temperaturmessstelle,SG10,CCI,7059,00403,Z99,,Messstelle desTagesparameters(derzeit ist nur dieTemperatur ein erlaubterTagesparameter),, + 180,Klimazone / Temperaturmessstelle,SG10,CCI,7059,,ZA0,,Klimazone desTagesparameters(derzeit istTagesparameter),, + 181,Klimazone / Temperaturmessstelle,SG10,CCI,7037,00403,,,ID Klimazone /Temperaturmessstelle,, + 182,Klimazone / Temperaturmessstelle,SG10,CCI,1131,00403,,,Dienstanbieter,,[58] Wenn in diesem CCI das DE3055 mit dem Code 293 vorhanden + 183,Klimazone / Temperaturmessstelle,SG10,CCI,3055,00403,89,,Vergeben vom Händler(hier Netzbetreiber),, + 184,Klimazone / Temperaturmessstelle,SG10,CCI,3055,,293,,"DE, BDEW(Bundesverband derEnergie- undWasserwirtschaft e.V.)",, + 185,Beteiligter Marktpartner MP-ID,SG12,,,,,,,,[570] Hinweis: Netzbetreiber Alt + 186,Beteiligter Marktpartner MP-ID,SG12,NAD,,00533,,,,, + 187,Beteiligter Marktpartner MP-ID,SG12,NAD,3035,00533,VY,,andere zugehörige Partei,, + 188,Beteiligter Marktpartner MP-ID,SG12,NAD,3039,00533,,,MP-ID,, + 189,Beteiligter Marktpartner MP-ID,SG12,NAD,3055,00533,9,,GS1,, + 190,Beteiligter Marktpartner MP-ID,SG12,NAD,3055,,293,,"DE, BDEW(Bundesverband der",, + 191,Referenz auf die ID einer Marktlokation / Tranche,SG12,RFF,,00534,,,,, + 192,Referenz auf die ID einer Marktlokation / Tranche,SG12,RFF,1153,00534,Z18,,Marktlokation,, + 193,Referenz auf die ID einer Marktlokation / Tranche,SG12,RFF,1153,,Z20,,Tranche,, + 194,Referenz auf die ID einer Marktlokation / Tranche,SG12,RFF,1154,00534,,,ID einer Marktlokation / Tranche,,[950] Format: Marktlokations-ID + 195,Nachrichten-Endesegment,,UNT,,00540,,,,Muss, + 196,Nachrichten-Endesegment,,UNT,0074,00540,,,Anzahl der Segmente in einerNachricht,X, + 197,Nachrichten-Endesegment,,UNT,0062,00540,,,Nachrichten-Referenznummer,X, + + ''' +# --- +# name: TestCli.test_kohlrahbi_cli_with_valid_arguments[55115] + ''' + ,Segmentname,Segmentgruppe,Segment,Datenelement,Segment ID,Code,Qualifier,Beschreibung,Bedingungsausdruck,Bedingung + 0,Nachrichten-Kopfsegment,,UNH,,00003,,,,Muss, + 1,Nachrichten-Kopfsegment,,UNH,0062,00003,,,Nachrichten-Referenznummer,X, + 2,Nachrichten-Kopfsegment,,UNH,0065,00003,UTILMD,,Netzanschluss-Stammdaten,X, + 3,Nachrichten-Kopfsegment,,UNH,0052,00003,D,,Entwurfs-Version,X, + 4,Nachrichten-Kopfsegment,,UNH,0054,00003,11A,,Ausgabe 2011 - A,X, + 5,Nachrichten-Kopfsegment,,UNH,0051,00003,UN,,UN/CEFACT,X, + 6,Nachrichten-Kopfsegment,,UNH,0057,00003,Versionsnummer derzugrundeliegendenBDEW-Nachrichtenbeschreibung,,S1.1a,X, + 7,Beginn der Nachricht,,BGM,,00004,,,,Muss, + 8,Beginn der Nachricht,,BGM,1001,00004,E03,,Änderungsmeldungen,X, + 9,Beginn der Nachricht,,BGM,1004,00004,,,Dokumentennummer,X, + 10,Nachrichtendatum,,DTM,,00005,,,,Muss, + 11,Nachrichtendatum,,DTM,2005,00005,137,,Dokumenten-/Nachrichtendatum/-zeit,X, + 12,Nachrichtendatum,,DTM,2380,00005,,,"Datum oder Uhrzeit oderZeitspanne, Wert",X [931][494],"[494] Das hier genannte Datum muss der Zeitpunkt sein, zu dem das Dokument erstellt wurde, oder ein Zeitpunkt, der davor liegt + [931] Format: ZZZ = +00" + 13,Nachrichtendatum,,DTM,2379,00005,303,,CCYYMMDDHHMMZZZ,X, + 14,MP-ID Absender,SG2,,,,,,,Muss, + 15,MP-ID Absender,SG2,NAD,,00008,,,,Muss, + 16,MP-ID Absender,SG2,NAD,3035,00008,MS,,Dokumenten-/Nachrichtenausstellerbzw. -absender,X, + 17,MP-ID Absender,SG2,NAD,3039,00008,,,MP-ID,X, + 18,MP-ID Absender,SG2,NAD,3055,00008,9,,GS1,X, + 19,MP-ID Absender,SG2,NAD,3055,,293,,"DE, BDEW(Bundesverband derEnergie- undWasserwirtschaft e.V.)",X, + 20,Ansprechpartner,SG3,,,,,,,Kann, + 21,Ansprechpartner,SG3,CTA,,00009,,,,Muss, + 22,Ansprechpartner,SG3,CTA,3139,00009,IC,,Informationskontakt,X, + 23,Ansprechpartner,SG3,CTA,3412,00009,,,Name vom Ansprechpartner,X, + 24,Kommunikationsverbindung,SG3,COM,,00010,,,,Muss, + 25,Kommunikationsverbindung,SG3,COM,3148,00010,,,Nummer / Adresse,X (([939][321]) ∨([940][322])) ∧[514],"[321] Wenn im DE3155 in demselben COM der Code EM vorhanden ist + [322] Wenn im DE3155 in demselben COM der Code TE / FX / AJ / AL vorhanden ist + [514] Hinweis: Es darf nur eine Information im DE3148 übermittelt werden + [939] Format: Die Zeichenkette muss die Zeichen @ und . enthalten + [940] Format: Die Zeichenkette muss mit dem Zeichen + beginnen und danach dürfen nur noch Ziffern folgen" + 26,Kommunikationsverbindung,SG3,COM,3155,00010,EM,,Elektronische Post,X [1P0..1], + 27,Kommunikationsverbindung,SG3,COM,3155,,FX,,Telefax,X [1P0..1], + 28,Kommunikationsverbindung,SG3,COM,3155,,TE,,Telefon,X [1P0..1], + 29,Kommunikationsverbindung,SG3,COM,3155,,AJ,,weiteres Telefon,X [1P0..1], + 30,Kommunikationsverbindung,SG3,COM,3155,,AL,,Handy,X [1P0..1], + 31,MP-ID Empfänger,SG2,,,,,,,Muss, + 32,MP-ID Empfänger,SG2,NAD,,00011,,,,Muss, + 33,MP-ID Empfänger,SG2,NAD,3035,00011,MR,,Nachrichtenempfänger,X, + 34,MP-ID Empfänger,SG2,NAD,3039,00011,,,MP-ID,X, + 35,MP-ID Empfänger,SG2,NAD,3055,00011,9,,GS1,X, + 36,MP-ID Empfänger,SG2,NAD,3055,,293,,"DE, BDEW(Bundesverband derEnergie- undWasserwirtschaft e.V.)",X, + 37,Vorgang,SG4,,,,,,,Muss, + 38,Vorgang,SG4,IDE,,00020,,,,Muss, + 39,Vorgang,SG4,IDE,7495,00020,24,,Transaktion,X, + 40,Vorgang,SG4,IDE,7402,00020,,,Vorgangsnummer,X, + 41,Beginn zum,SG4,DTM,,00024,,,,, + 42,Beginn zum,SG4,DTM,2005,00024,92,,Datum Vertragsbeginn,, + 43,Beginn zum,SG4,DTM,2380,00024,,,"Datum oder Uhrzeit oderZeitspanne, Wert",, + 44,Beginn zum,SG4,DTM,2379,00024,303,,CCYYMMDDHHMMZZZ,, + 45,"Änderung zum, Gültigkeit, Beginndatum",SG4,DTM,,00027,,,,, + 46,"Änderung zum, Gültigkeit, Beginndatum",SG4,DTM,2005,00027,157,,"Gültigkeit, Beginndatum",, + 47,"Änderung zum, Gültigkeit, Beginndatum",SG4,DTM,2380,00027,,,"Datum oder Uhrzeit oderZeitspanne, Wert",, + 48,"Änderung zum, Gültigkeit, Beginndatum",SG4,DTM,2379,00027,303,,CCYYMMDDHHMMZZZ,, + 49,Transaktionsgrund,SG4,STS,,00037,,,,Muss [2061],[2061] Segment bzw. Segmentgruppe ist genau einmal je SG4 IDE (Vorgang) anzugeben + 50,Transaktionsgrund,SG4,STS,9015,00037,7,,Transaktionsgrund,X, + 51,Transaktionsgrund,SG4,STS,9013,00037,ZE7,,Nicht bila.rel. Änderungvom NB,X, + 52,Status der Antwort,SG4,STS,,00039,,,,Muss [249],[249] Innerhalb eines SG4 IDE müssen alle DE1131 der SG4 STS+E01 den identischen Wert enthalten + 53,Status der Antwort,SG4,STS,9015,00039,E01,,Status der Antwort,X, + 54,Status der Antwort,SG4,STS,9013,00039,,,Code des Prüfschritts,X, + 55,Status der Antwort,SG4,STS,1131,00039,Codeliste Strom Nr.S_0005Codeliste Strom Nr.S_0006,,S_0005S_0006,X [5]X [135],"[5] Wenn MP-ID in SG2 NAD+MS (Nachrichtenabsender) in der Rolle LF + [135] Wenn MP-ID in SG2 NAD+MS (Nachrichtenabsender) in der Rolle MSB" + 56,Netzlokation,SG5,,,,,,,Muss [2061]∧ [298] ∧[299] ∧[347] ∧[348] ∧[349],"[298] Wenn SG5 LOC+Z20 (Technische Ressource) nicht vorhanden + [299] Wenn SG5 LOC+Z19 (Steuerbare Ressource) nicht vorhanden " + 57,Netzlokation,SG5,LOC,,00050,,,,Muss, + 58,Netzlokation,SG5,LOC,3227,00050,Z18,,Netzlokation,X, + 59,Netzlokation,SG5,LOC,3225,00050,,,ID der Netzlokation,X [960],[960] Format: Netzlokations-ID + 60,Marktlokation,SG5,,,,,,,Muss [2061]∧ [297] ∧[298] ∧[299] ∧[348] ∧[349],"[297] Wenn SG5 LOC+Z18 (Netzlokation) nicht vorhanden + [298] Wenn SG5 LOC+Z20 (Technische Ressource) nicht vorhanden + [299] Wenn SG5 LOC+Z19 (Steuerbare Ressource) nicht vorhanden + [348] Wenn SG5 LOC+Z21 (Tranche) nicht vorhanden + [349] Wenn SG5 LOC+Z17 (Messlokation) nicht vorhanden + [2061] Segment bzw. Segmentgruppe ist genau einmal je SG4 IDE (Vorgang) anzugeben" + 61,Marktlokation,SG5,LOC,,00051,,,,Muss, + 62,Marktlokation,SG5,LOC,3227,00051,Z16,,Marktlokation,X, + 63,Marktlokation,SG5,LOC,3225,00051,,,ID der Marktlokation,X [950],[950] Format: Marktlokations-ID + 64,Technische Ressource,SG5,,,,,,,Muss [2061]∧ [297] ∧[299] ∧[347] ∧[348] ∧[349],"[297] Wenn SG5 LOC+Z18 (Netzlokation) nicht vorhanden + [299] Wenn SG5 LOC+Z19 (Steuerbare Ressource) nicht vorhanden + [347] Wenn SG5 LOC+Z16 (Marktlokation) nicht vorhanden + [348] Wenn SG5 LOC+Z21 (Tranche) nicht vorhanden + [349] Wenn SG5 LOC+Z17 (Messlokation) nicht vorhanden + [2061] Segment bzw. Segmentgruppe ist genau einmal je SG4 IDE (Vorgang) anzugeben" + 65,Technische Ressource,SG5,LOC,,00052,,,,Muss, + 66,Technische Ressource,SG5,LOC,3227,00052,Z20,,Technische Ressource,X, + 67,Technische Ressource,SG5,LOC,3225,00052,,,ID der Technischen Ressource,X [922],[922] Format: TR-ID + 68,Steuerbare Ressource,SG5,,,,,,,Muss [2061]∧ [297] ∧[298] ∧[347] ∧[348] ∧[349],"[297] Wenn SG5 LOC+Z18 (Netzlokation) nicht vorhanden + [298] Wenn SG5 LOC+Z20 (Technische Ressource) nicht vorhanden + [347] Wenn SG5 LOC+Z16 (Marktlokation) nicht vorhanden + [348] Wenn SG5 LOC+Z21 (Tranche) nicht vorhanden + [349] Wenn SG5 LOC+Z17 (Messlokation) nicht vorhanden + [2061] Segment bzw. Segmentgruppe ist genau einmal je SG4 IDE" + 69,Steuerbare Ressource,SG5,LOC,,00053,,,,Muss, + 70,Steuerbare Ressource,SG5,LOC,3227,00053,Z19,,Steuerbare Ressource,X, + 71,Steuerbare Ressource,SG5,LOC,3225,00053,,,ID der Steuerbaren Ressource,X [961],[961] Format: SR-ID + 72,Tranche,SG5,,,,,,,Muss [2061]∧ [297] ∧[298] ∧[299] ∧[347] ∧[349],"[297] Wenn SG5 LOC+Z18 (Netzlokation) nicht vorhanden + [298] Wenn SG5 LOC+Z20 (Technische Ressource) nicht vorhanden + [299] Wenn SG5 LOC+Z19 (Steuerbare Ressource) nicht vorhanden + [347] Wenn SG5 LOC+Z16 (Marktlokation) nicht vorhanden + [349] Wenn SG5 LOC+Z17 (Messlokation) nicht vorhanden + [2061] Segment bzw. Segmentgruppe ist genau einmal je SG4 IDE (Vorgang) anzugeben" + 73,Tranche,SG5,LOC,,00054,,,,Muss, + 74,Tranche,SG5,LOC,3227,00054,Z21,,Tranche,X, + 75,Tranche,SG5,LOC,3225,00054,,,ID der Tranche,X [950],[950] Format: Marktlokations-ID + 76,Messlokation,SG5,,,,,,,Muss [2061]∧ [297] ∧[298] ∧[299] ∧[347] ∧[348],"[297] Wenn SG5 LOC+Z18 (Netzlokation) nicht vorhanden + [298] Wenn SG5 LOC+Z20 (Technische Ressource) nicht vorhanden + [299] Wenn SG5 LOC+Z19 (Steuerbare Ressource) nicht vorhanden + [347] Wenn SG5 LOC+Z16 (Marktlokation)" + 77,Messlokation,SG5,LOC,,00055,,,,Muss, + 78,Messlokation,SG5,LOC,3227,00055,Z17,,Messlokation,X, + 79,Messlokation,SG5,LOC,3225,00055,,,ID der Messlokation,X [951],[951] Format: Zählpunktbezeichnung + 80,Prüfidentifikator,SG6,,,,,,,Muss, + 81,Prüfidentifikator,SG6,RFF,,00057,,,,Muss, + 82,Prüfidentifikator,SG6,RFF,1153,00057,Z13,,Prüfidentifikator,X, + 83,Prüfidentifikator,SG6,RFF,1154,00057,55112,,SDÄ Strom / Nicht bila.rel. Änderung vom NB anLF,, + 84,Prüfidentifikator,SG6,RFF,1154,,55113,,SDÄ Strom / Nicht bila.rel. Änderung vom NB anMSB,, + 85,Prüfidentifikator,SG6,RFF,1154,,55115,,SDÄ Strom / Antwort aufÄnderung vom NB AG anNB,X, + 86,Referenz Vorgangsnummer (aus Anfragenachricht),SG6,,,,,,,Muss, + 87,Referenz Vorgangsnummer (aus Anfragenachricht),SG6,RFF,,00058,,,,Muss, + 88,Referenz Vorgangsnummer (aus Anfragenachricht),SG6,RFF,1153,00058,TN,,Transaktions-Referenznummer,X, + 89,Referenz Vorgangsnummer (aus Anfragenachricht),SG6,RFF,1154,00058,,,Vorgangsnummer,X, + 90,Referenz auf die ID der Marktlokation für Termine der Marktlokation,SG6,,,,,,,,"[25] Wenn SG5 LOC+Z16 (Marktlokation) vorhanden + [92] Wenn Wert innerhalb SG bzw. Segment geändert wird" + 91,Referenz auf die ID der Marktlokation für Termine der Marktlokation,SG6,RFF,,00066,,,,,[636] Hinweis: Dieses RFF klassifiziert mit einem Code im DE1153 die in derselben Segmentgruppe enthaltenen DTM zu einem Markt- bzw. + 92,Referenz auf die ID der Marktlokation für Termine der Marktlokation,SG6,RFF,1153,00066,Z18,,Marktlokation,, + 93,Referenz auf die ID der Marktlokation für Termine der Marktlokation,SG6,RFF,1154,00066,,,ID der Marktlokation,,[950] Format: Marktlokations-ID + 94,Termin der Netznutzungsabrechnung,SG6,DTM,,00068,,,,,[92] Wenn Wert innerhalb SG bzw. Segment geändert wird + 95,Termin der Netznutzungsabrechnung,SG6,DTM,2005,00068,Z21,,Termin derNetznutzungsabrechnung,, + 96,Termin der Netznutzungsabrechnung,SG6,DTM,2380,00068,,,"Datum oder Uhrzeit oderZeitspanne, Wert",, + 97,Termin der Netznutzungsabrechnung,SG6,DTM,2379,00068,106,,MMDD,, + 98,Termin der Netznutzungsabrechnung,SG6,DTM,2379,,104,,MMWW-MMWW,, + 99,Nächste Netznutzungsabrechnung,SG6,DTM,,00069,,,,,"[24] Wenn SG6 DTM+Z21 (Termin der Netznutzungsabrechnun g) vorhanden + [230] Sich ergebendes Datum/ bzw. Endedatum des Turnuszeitraums aus DTM+Z21 (Termin der Netznutzungsabrechnun g) und DTM+Z09 (Nächste Netznutzungsabrechnun g) muss >= DTM+92 (Beginn zum) sein" + 100,Nächste Netznutzungsabrechnung,SG6,DTM,2005,00069,Z09,,NächsteNetznutzungsabrechnung,, + 101,Nächste Netznutzungsabrechnung,SG6,DTM,2380,00069,,,"Datum oder Uhrzeit oderZeitspanne, Wert",, + 102,Nächste Netznutzungsabrechnung,SG6,DTM,2379,00069,602,,CCYY,, + 103,Netznutzungsabrechnungsi ntervall des NB,SG6,DTM,,00070,,,,,[92] Wenn Wert innerhalb SG bzw. Segment geändert wird + 104,Netznutzungsabrechnungsi ntervall des NB,SG6,DTM,2005,00070,Z22,,Netznutzungsabrechnungs- bzw.Einspeisevergütungsinter,, + 105,Netznutzungsabrechnungsi ntervall des NB,SG6,DTM,2380,00070,,,"Datum oder Uhrzeit oderZeitspanne, Wert",, + 106,Netznutzungsabrechnungsi ntervall des NB,SG6,DTM,2379,00070,802,,Monat,, + 107,Daten der Netzlokation,SG8,,,,,,,,[294] Wenn SG5 LOC+Z18 (Netzlokation) vorhanden + 108,Daten der Netzlokation,SG8,SEQ,,00078,,,,, + 109,Daten der Netzlokation,SG8,SEQ,1229,00078,Z51,,Daten der Netzlokation,, + 110,Referenz auf die ID der Netzlokation,SG8,RFF,,00079,,,,, + 111,Referenz auf die ID der Netzlokation,SG8,RFF,1153,00079,Z32,,Netzlokation,, + 112,Referenz auf die ID der Netzlokation,SG8,RFF,1154,00079,,,ID der Netzlokation,,[960] Format: Netzlokations-ID + 113,Zugeordnete Marktpartner,SG10,,,,,,,, + 114,Zugeordnete Marktpartner,SG10,CCI,,00081,,,,, + 115,Zugeordnete Marktpartner,SG10,CCI,7037,00081,ZB3,,ZugeordneterMarktpartner,, + 116,Messstellenbetreiber,SG10,CAV,,00082,,,,, + 117,Messstellenbetreiber,SG10,CAV,7111,00082,Z91,,MSB,, + 118,Messstellenbetreiber,SG10,CAV,1131,00082,,,MP-ID,, + 119,Messstellenbetreiber,SG10,CAV,7110,00082,Z39,,GrundzuständigerMessstellenbetreiber,, + 120,Messstellenbetreiber,SG10,CAV,7110,,Z40,,WettbewerblicherMessstellenbetreiber,, + 121,Messstellenbetreiber,SG10,CAV,7110,,Z41,,Auffangmessstellenbetreiber,, + 122,Daten der Marktlokation,SG8,,,,,,,,"[25] Wenn SG5 LOC+Z16 (Marktlokation) vorhanden + [92] Wenn Wert innerhalb SG bzw. Segment geändert wird + [2061] Segment bzw. Segmentgruppe ist genau einmal je SG4 IDE (Vorgang) anzugeben" + 123,Daten der Marktlokation,SG8,SEQ,,00103,,,,, + 124,Daten der Marktlokation,SG8,SEQ,1229,00103,Z01,,Daten der Marktlokation,, + 125,Referenz auf die ID der Marktlokation,SG8,RFF,,00104,,,,, + 126,Referenz auf die ID der Marktlokation,SG8,RFF,1153,00104,Z18,,Marktlokation,, + 127,Referenz auf die ID der Marktlokation,SG8,RFF,1154,00104,,,ID der Marktlokation,,[950] Format: Marktlokations-ID + 128,Lieferrichtung,SG10,,,,,,,, + 129,Lieferrichtung,SG10,CCI,,00110,,,,, + 130,Lieferrichtung,SG10,CCI,7059,00110,Z30,,Lieferrichtung,, + 131,Lieferrichtung,SG10,CCI,7037,00110,Z06,,Erzeugung,, + 132,Lieferrichtung,SG10,CCI,7037,,Z07,,Verbrauch,, + 133,Zugeordnete Marktpartner,SG10,,,,,,,,[92] Wenn Wert innerhalb SG bzw. Segment geändert wird + 134,Zugeordnete Marktpartner,SG10,CCI,,00111,,,,, + 135,Zugeordnete Marktpartner,SG10,CCI,7037,00111,ZB3,,ZugeordneterMarktpartner,, + 136,Lieferant,SG10,CAV,,00113,,,,,"[20] Wenn SG8 SEQ+Z01 (Daten der Marktlokation) SG10 CCI+Z30++Z07 (Verbrauch) vorhanden + [369] Wenn Marktlokation nicht tranchiert" + 137,Lieferant,SG10,CAV,7111,00113,Z89,,LF,, + 138,Lieferant,SG10,CAV,1131,00113,,,MP-ID,,"[611] Hinweis: Wenn das Unternehmen NB die Aufgaben der Marktrolle LF wahrnimmt, ist die MP-ID des Unternehmens NB in der Marktrolle LF anzugeben" + 139,Übertragungsnetzbetreiber,SG10,CAV,,00114,,,,, + 140,Übertragungsnetzbetreiber,SG10,CAV,7111,00114,Z90,,ÜNB,, + 141,Übertragungsnetzbetreiber,SG10,CAV,1131,00114,,,MP-ID,, + 142,Messstellenbetreiber,SG10,CAV,,00115,,,,, + 143,Messstellenbetreiber,SG10,CAV,7111,00115,Z91,,MSB,, + 144,Messstellenbetreiber,SG10,CAV,1131,00115,,,MP-ID,, + 145,Messstellenbetreiber,SG10,CAV,7110,00115,Z19,,Auf vertraglicherGrundlage gegenüberAnschlussnutzer /Anschlussnehmer,, + 146,Messstellenbetreiber,SG10,CAV,7110,,Z20,,In der Ausübung derWeiterverpflichtungdurch den gMSB,, + 147,Messstellenbetreiber,SG10,CAV,7110,00115,Z39,,GrundzuständigerMessstellenbetreiber,, + 148,Messstellenbetreiber,SG10,CAV,7110,,Z40,,WettbewerblicherMessstellenbetreiber,, + 149,Messstellenbetreiber,SG10,CAV,7110,,Z41,,Auffangmessstellenbetreiber,, + 150,Verbrauchsaufteilung für temperaturabhängige Marktlokation,SG10,,,,,,,,[92] Wenn Wert innerhalb SG bzw. Segment geändert wird + 151,Verbrauchsaufteilung für temperaturabhängige Marktlokation,SG10,CCI,,00119,,,,, + 152,Verbrauchsaufteilung für temperaturabhängige Marktlokation,SG10,CCI,7037,00119,E17,,Verbrauchsaufteilung (in%) fürtemperaturabhängigeMarktlokation,, + 153,Verbrauchsaufteilung für temperaturabhängige Marktlokation,SG10,CAV,,00120,,,,, + 154,Verbrauchsaufteilung für temperaturabhängige Marktlokation,SG10,CAV,7111,00120,Z22,,Verbrauchsaufteilung in%,, + 155,Verbrauchsaufteilung für temperaturabhängige Marktlokation,SG10,CAV,7110,00120,,,Verbrauchsaufteilung in %,,[902] Format: Möglicher Wert: ≥ 0 + 156,Spannungsebene der Marktlokation,SG10,,,,,,,,[92] Wenn Wert innerhalb SG bzw. Segment geändert wird + 157,Spannungsebene der Marktlokation,SG10,CCI,,00123,,,,, + 158,Spannungsebene der Marktlokation,SG10,CCI,7037,00123,E03,,Spannungsebene derMarktlokation,, + 159,Spannungsebene der Marktlokation,SG10,CAV,,00124,,,,, + 160,Spannungsebene der Marktlokation,SG10,CAV,7111,00124,E03,,Höchstspannung,, + 161,Spannungsebene der Marktlokation,SG10,CAV,7111,,E04,,Hochspannung,, + 162,Spannungsebene der Marktlokation,SG10,CAV,7111,,E05,,Mittelspannung,, + 163,Spannungsebene der Marktlokation,SG10,CAV,7111,,E06,,Niederspannung,, + 164,Umspannung der Marktlokation,SG10,CAV,,00125,,,,,[166] Wenn vorhanden + 165,Umspannung der Marktlokation,SG10,CAV,7111,00125,E07,,Hös/HS Umspannung,, + 166,Umspannung der Marktlokation,SG10,CAV,7111,,E08,,HS/MS Umspannung,, + 167,Umspannung der Marktlokation,SG10,CAV,7111,,E09,,MS/NS Umspannung,,"[114] Wenn das SG10 CCI+E03 (Spannungsebene der Marktlokation) CAV E06 (Niederspannung) in dieser SG vorhanden + [115] Wenn das SG10 CCI+E03 (Spannungsebene der Marktlokation) CAV E05 (Mittelspannung) in dieser SG vorhanden + [116] Wenn das SG10 CCI+E03 (Spannungsebene der Marktlokation) CAV E04 (Hochspannung) in dieser SG vorhanden" + 168,Messtechnische Einordnung der Marktlokation,SG10,,,,,,,, + 169,Messtechnische Einordnung der Marktlokation,SG10,CCI,,00126,,,,, + 170,Messtechnische Einordnung der Marktlokation,SG10,CCI,7037,00126,Z83,,MesstechnischeEinordnung derMarktlokation,, + 171,Messtechnische Einordnung der Marktlokation,SG10,CAV,,00127,,,,, + 172,Messtechnische Einordnung der Marktlokation,SG10,CAV,7111,00127,Z52,,iMS,, + 173,Messtechnische Einordnung der Marktlokation,SG10,CAV,7111,,Z53,,kME / mME,, + 174,Messtechnische Einordnung der Marktlokation,SG10,CAV,7111,,Z68,,keine Messung,, + 175,Netznutzung,SG10,,,,,,,,"[20] Wenn SG8 SEQ+Z01 (Daten der Marktlokation) SG10 CCI+Z30++Z07 (Verbrauch) vorhanden + [92] Wenn Wert innerhalb SG bzw. Segment geändert wird" + 176,Netznutzung,SG10,CCI,,00140,,,,, + 177,Netznutzung,SG10,CCI,7037,00140,Z88,,Netznutzung,, + 178,Netznutzungsvertrag,SG10,CAV,,00141,,,,, + 179,Netznutzungsvertrag,SG10,CAV,7111,00141,Z74,,Netznutzungsvertrag,, + 180,Netznutzungsvertrag,SG10,CAV,7110,00141,Z08,,Direkter Vertragzwischen Kunden und NB,, + 181,Netznutzungsvertrag,SG10,CAV,7110,,Z09,,Vertrag zwischenLieferanten und NB,, + 182,Zahlung der Netznutzung,SG10,CAV,,00142,,,,, + 183,Zahlung der Netznutzung,SG10,CAV,7111,00142,Z73,,Zahlung der Netznutzung,, + 184,Zahlung der Netznutzung,SG10,CAV,7110,00142,Z10,,Kunde,, + 185,Zahlung der Netznutzung,SG10,CAV,7110,,Z11,,Lieferant,,[216] Wenn CCI+++Z88 (Netznutzung) CAV+Z74:::Z08 (Netznutzungsvertrag: Direkter Vertrag zwischen Kunden und NB) vorhanden + 186,Netznutzungsabrechnungsv ariante,SG10,CAV,,00143,,,,, + 187,Netznutzungsabrechnungsv ariante,SG10,CAV,7111,00143,ZB1,,Netznutzungsabrechnungsvariante,, + 188,Netznutzungsabrechnungsv ariante,SG10,CAV,7110,00143,Z14,,Arbeitspreis/Grundpreis,, + 189,Netznutzungsabrechnungsv ariante,SG10,CAV,7110,,Z15,,Arbeitspreis/Leistungspreis,, + 190,Grundlage der Lieferscheinprüfung,SG10,CAV,,00144,,,,, + 191,Grundlage der Lieferscheinprüfung,SG10,CAV,7111,00144,ZA7,,Grundlage fürLieferscheinprüfung,, + 192,Grundlage der Lieferscheinprüfung,SG10,CAV,7110,00144,Z12,,In derMarktkommunikationausgetauschte Daten,, + 193,Grundlage der Lieferscheinprüfung,SG10,CAV,7110,,Z13,,Abweichend vertraglichmit Anschlussnutzervereinbarte Grundlage,, + 194,Singulär genutzte Betriebsmittel in der Netznutzungsabrechnung,SG10,CAV,,00145,,,,,[308] Wenn DTM+92 (Beginn zum) im DE2380 < 202212312300?+00 + 195,Singulär genutzte Betriebsmittel in der Netznutzungsabrechnung,SG10,CAV,7111,00145,ZB2,,Singulär genutzteBetriebsmittel in der,, + 196,Singulär genutzte Betriebsmittel in der Netznutzungsabrechnung,SG10,CAV,7110,00145,Z06,,vorhanden,, + 197,Singulär genutzte Betriebsmittel in der Netznutzungsabrechnung,SG10,CAV,7110,,Z07,,nicht vorhanden,, + 198,Empfänger der Vergütung zur Einspeisung,SG10,,,,,,,,"[54] Wenn SG8 SEQ+Z01 (Daten der Marktlokation) SG10 CCI+Z30++Z06 (Lieferrichtung: Erzeugung) vorhanden + [92] Wenn Wert innerhalb SG bzw. Segment geändert wird" + 199,Empfänger der Vergütung zur Einspeisung,SG10,CCI,,00146,,,,, + 200,Empfänger der Vergütung zur Einspeisung,SG10,CCI,7037,00146,Z89,,Empfänger derVergütung,, + 201,Empfänger der Vergütung zur Einspeisung,SG10,CAV,,00147,,,,, + 202,Empfänger der Vergütung zur Einspeisung,SG10,CAV,7110,00147,Z10,,Kunde,, + 203,Empfänger der Vergütung zur Einspeisung,SG10,CAV,7110,,Z11,,Lieferant,, + 204,Status der Fernsteuerbarkeit,SG10,,,,,,,,"[54] Wenn SG8 SEQ+Z01 (Daten der Marktlokation) SG10 CCI+Z30++Z06 (Lieferrichtung: Erzeugung) vorhanden + [92] Wenn Wert innerhalb SG bzw. Segment geändert wird" + 205,Status der Fernsteuerbarkeit,SG10,CCI,,00150,,,,, + 206,Status der Fernsteuerbarkeit,SG10,CCI,7059,00150,Z24,,Status derFernsteuerbarkeit,, + 207,Status der Fernsteuerbarkeit,SG10,CCI,7037,00150,Z96,,Marktlokation isttechnisch nichtfernsteuerbar,, + 208,Status der Fernsteuerbarkeit,SG10,CCI,7037,,Z97,,Marktlokation isttechnisch fernsteuerbar,, + 209,Status der Fernsteuerbarkeit,SG10,CCI,7037,,Z98,,Marktlokation ist durchden Lieferantenfernsteuerbar,, + 210,Verbrauchsart und Nutzung der OBIS-Kennzahl der Marktlokation,SG8,,,,,,,,"[25] Wenn SG5 LOC+Z16 (Marktlokation) vorhanden + [92] Wenn Wert innerhalb SG bzw. Segment geändert wird + [530] Hinweis: Es sind alle an der Lokation vorhandenen Daten, die mit dieser Segmentgruppe übermittelt werden und zum Datum „Änderung zum“ Gültigkeit haben, anzugeben. Dies kann zur Folge haben, dass Segmentgruppen bzw. Segmente zu wiederholen sind" + 211,Verbrauchsart und Nutzung der OBIS-Kennzahl der Marktlokation,SG8,SEQ,,00216,,,,, + 212,Verbrauchsart und Nutzung der OBIS-Kennzahl der Marktlokation,SG8,SEQ,1229,00216,Z44,,Verbrauchsart undNutzung der OBIS-Kennzahl an derMarktlokation,, + 213,Referenz auf die OBIS- Kennzahl der Marktlokation,SG8,RFF,,00217,,,,, + 214,Referenz auf die OBIS- Kennzahl der Marktlokation,SG8,RFF,1153,00217,Z10,,OBIS-Kennzahl,, + 215,Referenz auf die OBIS- Kennzahl der Marktlokation,SG8,RFF,1154,00217,,,OBIS-Kennzahl,, + 216,Verbrauchsart und Nutzung an der OBIS-Kennzahl der Marktlokation,SG10,,,,,,,, + 217,Verbrauchsart und Nutzung an der OBIS-Kennzahl der Marktlokation,SG10,CCI,,00218,,,,, + 218,Verbrauchsart und Nutzung an der OBIS-Kennzahl der Marktlokation,SG10,CCI,7059,00218,Z17,,Stromverbrauchsart,, + 219,Verbrauchsart,SG10,CAV,,00219,,,,, + 220,Verbrauchsart,SG10,CAV,7111,00219,Z64,,Kraft/Licht,, + 221,Verbrauchsart,SG10,CAV,7111,,Z65,,Wärme,, + 222,Verbrauchsart,SG10,CAV,7111,,ZE5,,E-Mobilität,, + 223,Verbrauchsart,SG10,CAV,7111,,ZA8,,Straßenbeleuchtung,, + 224,Verbrauchsart,SG10,CAV,7111,,ZB3,,SteuerungWärmeabgabe,, + 225,Unterbrechbarkeit,SG10,CAV,,00220,,,,, + 226,Unterbrechbarkeit,SG10,CAV,7111,00220,Z62,,unterbrechbareVerbrauchseinrichtung,, + 227,Unterbrechbarkeit,SG10,CAV,7111,,Z63,,nicht-unterbrechbareVerbrauchseinrichtung,, + 228,Wärmenutzung,SG10,CAV,,00221,,,,,[239] Wenn in derselben SG10 das CCI+Z17 (Stromverbrauchsart) im CAV+Z65 (Wärme) vorhanden + 229,Wärmenutzung,SG10,CAV,7111,00221,Z56,,Speicherheizung,, + 230,Wärmenutzung,SG10,CAV,7111,,Z57,,Wärmepumpe,, + 231,Wärmenutzung,SG10,CAV,7111,,Z61,,Direktheizung,, + 232,Art der E-Mobilität,SG10,CAV,,00222,,,,,[95] Wenn in derselben SG10 das CCI+Z17 (Stromverbrauchsart) CAV+ZE5 (E-Mobilität) vorhanden + 233,Art der E-Mobilität,SG10,CAV,7111,00222,ZE6,,Wallbox,, + 234,Art der E-Mobilität,SG10,CAV,7111,,Z87,,E-Mobilitätsladesäule,, + 235,Art der E-Mobilität,SG10,CAV,7111,,ZE7,,Ladepark,, + 236,Produkt-Daten der Marktlokation des NB,SG8,,,,,,,,"[25] Wenn SG5 LOC+Z16 (Marktlokation) vorhanden + [54] Wenn SG8 SEQ+Z01 (Daten der Marktlokation) SG10 CCI+Z30++Z06 (Lieferrichtung: Erzeugung) vorhanden + [92] Wenn Wert innerhalb SG bzw. Segment geändert wird" + 237,Produkt-Daten der Marktlokation des NB,SG8,SEQ,,00227,,,,, + 238,Produkt-Daten der Marktlokation des NB,SG8,SEQ,1229,00227,Z40,,Produkt-Daten derMarktlokation des NB,, + 239,Produktidentifikation der Marktlokation,SG8,PIA,,00228,,,,,[262] Wenn Produkt an der Marktlokation vorhanden ist + 240,Produktidentifikation der Marktlokation,SG8,PIA,4347,00228,5,,Produktidentifikation,, + 241,Produktidentifikation der Marktlokation,SG8,PIA,7140,00228,AUA,,Ausfallarbeit,, + 242,Produktidentifikation der Marktlokation,SG8,PIA,7143,00228,Z08,,Medium,, + 243,Konzessionsabgabedaten,SG8,,,,,,,,"[25] Wenn SG5 LOC+Z16 (Marktlokation) vorhanden + [92] Wenn Wert innerhalb SG bzw. Segment geändert wird + [312] Wenn DTM+157 (Änderung zum) im DE2380 < 202212312300?+00 + [530] Hinweis: Es sind alle an der Lokation vorhandenen Daten, die mit dieser Segmentgruppe übermittelt werden und zum Datum „Änderung zum“ Gültigkeit haben, anzugeben. Dies kann zur Folge haben, dass Segmentgruppen bzw. Segmente zu wiederholen sind" + 244,Konzessionsabgabedaten,SG8,SEQ,,00229,,,,, + 245,Konzessionsabgabedaten,SG8,SEQ,1229,00229,Z07,,Konzessionsabgabedaten,, + 246,Referenz auf die OBIS- Kennzahl der Marktlokation,SG8,RFF,,00230,,,,, + 247,Referenz auf die OBIS- Kennzahl der Marktlokation,SG8,RFF,1153,00230,Z10,,OBIS-Kennzahl,, + 248,Referenz auf die OBIS- Kennzahl der Marktlokation,SG8,RFF,1154,00230,,,OBIS-Kennzahl,, + 249,Zuordnung Konzessionsabgabe,SG10,,,,,,,, + 250,Zuordnung Konzessionsabgabe,SG10,CCI,,00231,,,,, + 251,Zuordnung Konzessionsabgabe,SG10,CCI,7037,00231,Z08,,Konzessionsabgabe,, + 252,Konzessionsabgabe,SG10,CAV,,00232,,,,, + 253,Konzessionsabgabe,SG10,CAV,7111,00232,KAS,,"für allekonzessionsvertraglichenSonderregelungen, dienicht in die Systematikder KAV eingegliedertsind",, + 254,Konzessionsabgabe,SG10,CAV,7111,,SA,,"Sondervertragskunden <1 kV nach § 2 (7) und > 1kV, Preis nach § 2 (3) (fürStrom 0,11 ct/kWh undfür Gas 0,03 ct/kWh)",, + 255,Konzessionsabgabe,SG10,CAV,7111,,SAS,,"Kennzeichnung, dass einabweichender Preis fürSondervertragskundenvorliegt",, + 256,Konzessionsabgabe,SG10,CAV,7111,,TA,,"Tarifkunden, für Strom §2. (2) 1b HT bzw. ET(hohe KA) und für Gas §2 (2) 2b",, + 257,Konzessionsabgabe,SG10,CAV,7111,,TAS,,"Kennzeichnung, dass einabweichender Preis fürTarifkunden vorliegt",, + 258,Konzessionsabgabe,SG10,CAV,7111,,TKS,,"Kennzeichnung, wennnach KAV § 2 (2) 2a einanderer Preis zuverwenden ist",, + 259,Konzessionsabgabe,SG10,CAV,7111,,TS,,"für Strom mitSchwachlast § 2. (2) 1aNT (niedrige KA, 0,61ct/kWh)",, + 260,Konzessionsabgabe,SG10,CAV,7111,,TSS,,"Kennzeichnung, dass einabweichender Preis fürSchwachlast angewendetwird",, + 261,Konzessionsabgabe,SG10,CAV,7110,00232,,,Konzessionsabgabe in Euro/kWh,,"[128] Wenn SG10 CAV+TAS/ TSS/ TKS/ SAS/ KAS vorhanden + [902] Format: Möglicher Wert: ≥ 0 + [912] Format: max. 6 Nachkommastellen" + 262,Konzessionsabgabe,SG10,CAV,7110,00232,,,Gebührenkategorie derKonzessionsabgabe,,[219] Wenn an Marktlokation vorhanden + 263,Steuer-/ Abgabeninformation,SG8,,,,,,,,[25] Wenn SG5 LOC+Z16 (Marktlokation) + 264,Steuer-/ Abgabeninformation,SG8,SEQ,,00233,,,,, + 265,Steuer-/ Abgabeninformation,SG8,SEQ,1229,00233,Z10,,Steuer-/Abgabeninformation,, + 266,Referenz auf die OBIS- Kennzahl der Marktlokation,SG8,RFF,,00234,,,,, + 267,Referenz auf die OBIS- Kennzahl der Marktlokation,SG8,RFF,1153,00234,Z10,,OBIS-Kennzahl,, + 268,Referenz auf die OBIS- Kennzahl der Marktlokation,SG8,RFF,1154,00234,,,OBIS-Kennzahl,, + 269,Steuern-/Abgabenbefreiung,SG10,,,,,,,, + 270,Steuern-/Abgabenbefreiung,SG10,CCI,,00235,,,,, + 271,Steuern-/Abgabenbefreiung,SG10,CCI,7059,00235,Z13,,Steuerinformation,, + 272,Steuern-/Abgabenbefreiung,SG10,CCI,7037,00235,Z65,,Stromsteuer befreit,, + 273,Steuern-/Abgabenbefreiung,SG10,CCI,7037,,Z66,,Stromsteuer pflichtig,, + 274,Gemeinderabatt,SG8,,,,,,,,"[25] Wenn SG5 LOC+Z16 (Marktlokation) vorhanden + [92] Wenn Wert innerhalb SG bzw. Segment geändert wird + [312] Wenn DTM+157 (Änderung zum) im DE2380 <" + 275,Gemeinderabatt,SG8,SEQ,,00236,,,,, + 276,Gemeinderabatt,SG8,SEQ,1229,00236,Z12,,Gemeinderabatt,, + 277,Gemeinderabatt,SG9,,,,,,,, + 278,Gemeinderabatt,SG9,QTY,,00237,,,,, + 279,Gemeinderabatt,SG9,QTY,6063,00237,Z16,,Gemeinderabatt,, + 280,Gemeinderabatt,SG9,QTY,6060,00237,,,Menge,,"[902] Format: Möglicher Wert: ≥ 0 + [930] Format: max. 2 Nachkommastellen + [938] Format: Möglicher Wert: <= 10" + 281,Gemeinderabatt,SG9,QTY,6411,00237,P1,,Prozent,, + 282,Daten der Tranche,SG8,,,,,,,,"[92] Wenn Wert innerhalb SG bzw. Segment geändert wird + [167] Wenn SG5 LOC+Z21 (Tranche) vorhanden" + 283,Daten der Tranche,SG8,SEQ,,00238,,,,, + 284,Daten der Tranche,SG8,SEQ,1229,00238,Z15,,Daten der Tranche,, + 285,Referenz auf die ID der Tranche,SG8,RFF,,00239,,,,, + 286,Referenz auf die ID der Tranche,SG8,RFF,1153,00239,Z20,,Tranche,, + 287,Referenz auf die ID der Tranche,SG8,RFF,1154,00239,,,ID der Tranche,,[950] Format: Marktlokations-ID + 288,Prozentualer Anteil der Tranche an der erzeugenden Marktlokation,SG9,,,,,,,,[384] Wenn SG10 CCI+Z37++ZD1 (Basis zur Bildung der Tranchengröße) (Prozentual) vorhanden + 289,Prozentualer Anteil der Tranche an der erzeugenden Marktlokation,SG9,QTY,,00242,,,,, + 290,Prozentualer Anteil der Tranche an der erzeugenden Marktlokation,SG9,QTY,6063,00242,11,,Aufteilungsmenge,, + 291,Prozentualer Anteil der Tranche an der erzeugenden Marktlokation,SG9,QTY,6060,00242,,,Mengenangabe in %,,"[914] Format: Möglicher Wert: > 0 + [930] Format: max. 2 Nachkommastellen + [955] Format: Möglicher" + 292,Prozentualer Anteil der Tranche an der erzeugenden Marktlokation,SG9,QTY,6411,00242,P1,,Prozent,, + 293,Zugeordnete Marktpartner,SG10,,,,,,,, + 294,Zugeordnete Marktpartner,SG10,CCI,,00243,,,,, + 295,Zugeordnete Marktpartner,SG10,CCI,7037,00243,ZB3,,ZugeordneterMarktpartner,, + 296,Lieferant,SG10,CAV,,00244,,,,, + 297,Lieferant,SG10,CAV,7111,00244,Z89,,LF,, + 298,Lieferant,SG10,CAV,1131,00244,,,MP-ID,, + 299,Empfänger der Vergütung zur Einspeisung,SG10,,,,,,,, + 300,Empfänger der Vergütung zur Einspeisung,SG10,CCI,,00246,,,,, + 301,Empfänger der Vergütung zur Einspeisung,SG10,CCI,7037,00246,Z89,,Empfänger derVergütung,, + 302,Empfänger der Vergütung zur Einspeisung,SG10,CAV,,00247,,,,, + 303,Empfänger der Vergütung zur Einspeisung,SG10,CAV,7110,00247,Z10,,Kunde,, + 304,Empfänger der Vergütung zur Einspeisung,SG10,CAV,7110,,Z11,,Lieferant,, + 305,Basis zur Bildung der Tranchengröße,SG10,,,,,,,, + 306,Basis zur Bildung der Tranchengröße,SG10,CCI,,00248,,,,, + 307,Basis zur Bildung der Tranchengröße,SG10,CCI,7059,00248,Z37,,Basis zur Bildung derTranchengröße,, + 308,Basis zur Bildung der Tranchengröße,SG10,CCI,7037,00248,ZD1,,Prozentual,, + 309,Basis zur Bildung der Tranchengröße,SG10,CCI,7037,,ZD2,,Aufteilungsfaktor aufBasis vonReferenzenträger/installierter Leistung,, + 310,Daten der Technischen Ressource,SG8,,,,,,,,[296] Wenn SG5 LOC+Z20 (Technische Ressource) vorhanden + 311,Daten der Technischen Ressource,SG8,SEQ,,00273,,,,, + 312,Daten der Technischen Ressource,SG8,SEQ,1229,00273,Z52,,Daten der TechnischenRessource,, + 313,Referenz auf die ID der Technischen Ressource,SG8,RFF,,00274,,,,, + 314,Referenz auf die ID der Technischen Ressource,SG8,RFF,1153,00274,Z37,,Technische Ressource,, + 315,Referenz auf die ID der Technischen Ressource,SG8,RFF,1154,00274,,,ID der Technischen Ressource,,[922] Format: TR-ID + 316,Referenz auf die ID der vorgelagerten Messlokation,SG8,RFF,,00275,,,,,"[166] Wenn vorhanden + [668] Hinweis: Dieses Segment wird nach Abschluss der Einführung der Lokationsbündelstruktur zum 01.10.2025 aus der UTILMD entfernt" + 317,Referenz auf die ID der vorgelagerten Messlokation,SG8,RFF,1153,00275,Z34,,vorgelagerteMesslokation,, + 318,Referenz auf die ID der vorgelagerten Messlokation,SG8,RFF,1154,00275,,,ID einer Lokation,,[951] Format: Zählpunktbezeichnung + 319,Referenz auf die der Technischen Ressource zugeordneten Marktlokation ,SG8,RFF,,00276,,,,,[668] Hinweis: Dieses Segment wird nach Abschluss der Einführung der Lokationsbündelstruktur zum 01.10.2025 aus der UTILMD entfernt + 320,Referenz auf die der Technischen Ressource zugeordneten Marktlokation ,SG8,RFF,1153,00276,Z16,,zugeordneteMarktlokation,, + 321,Referenz auf die der Technischen Ressource zugeordneten Marktlokation ,SG8,RFF,1154,00276,,,ID der Marktlokation,,[950] Format: Marktlokations-ID + 322,Referenz auf die der Technischen Ressource zugeordneten Steuerbaren Ressource,SG8,RFF,,00277,,,,,"[166] Wenn vorhanden + [699] Hinweis: Es ist die ID der Steuerbare Ressource zu nennen über die die Technische Ressource gesteuert wird" + 323,Referenz auf die der Technischen Ressource zugeordneten Steuerbaren Ressource,SG8,RFF,1153,00277,Z38,,Steuerbare Ressource,, + 324,Referenz auf die der Technischen Ressource zugeordneten Steuerbaren Ressource,SG8,RFF,1154,00277,,,ID der Steuerbaren Ressource,,[961] Format: SR-ID + 325,Referenz auf die der Technischen Ressource zugeordneten Netzlokation,SG8,RFF,,00278,,,,,"[166] Wenn vorhanden + [700] Hinweis: Es ist die ID der Netzlokation zu nennen über die die Technische Ressource gesteuert wird" + 326,Referenz auf die der Technischen Ressource zugeordneten Netzlokation,SG8,RFF,1153,00278,Z32,,Netzlokation,, + 327,Referenz auf die der Technischen Ressource zugeordneten Netzlokation,SG8,RFF,1154,00278,,,ID der Netzlokation,,[960] Format: Netzlokations-ID + 328,Nennleistung (Aufnahme),SG9,,,,,,,,"[165] Wenn bekannt + [446] Wenn in derselben SG8 das CCI+Z17 (Stromverbrauchsart) vorhanden + [448] Wenn in derselben SG8 das CCI+Z56 (Speicher) vorhanden + [465] Wenn in derselben SG8 SEQ+Z52 (Daten der Technischen Ressource) das RFF+Z38 (Referenz auf die der Technischen Ressource zugeordnete Steuerbare Ressource) vorhanden ist + [466] Wenn in derselben SG8 SEQ+Z52 (Daten der Technischen Ressource) das RFF+Z32 (Referenz auf die der Technischen Ressource zugeordneten Netzlokation) vorhanden ist + [467] Wenn in derselben SG8 SEQ+Z52 (Daten der Technischen Ressource) das CAV+ZG8 (Technischen Ressource fällt unter §14a EnWG) vorhanden ist + [468] Wenn in derselben SG8 SEQ+Z52 (Daten der" + 329,Nennleistung (Aufnahme),SG9,QTY,,00279,,,,, + 330,Nennleistung (Aufnahme),SG9,QTY,6063,00279,Z43,,Nennleistung(Aufnahme),, + 331,Nennleistung (Aufnahme),SG9,QTY,6060,00279,,,Menge,, + 332,Nennleistung (Aufnahme),SG9,QTY,6411,00279,KWT,,Kilowatt,, + 333,Nennleistung (Abgabe),SG9,,,,,,,,"[447] Wenn in derselben SG8 das CCI+Z50 (Stromerzeugungsart) vorhanden + [448] Wenn in derselben SG8 das CCI+Z56 (Speicher) vorhanden" + 334,Nennleistung (Abgabe),SG9,QTY,,00280,,,,, + 335,Nennleistung (Abgabe),SG9,QTY,6063,00280,Z44,,Nennleistung (Abgabe),, + 336,Nennleistung (Abgabe),SG9,QTY,6060,00280,,,Menge,, + 337,Nennleistung (Abgabe),SG9,QTY,6411,00280,KWT,,Kilowatt,, + 338,Speicherkapazität,SG9,,,,,,,,[448] Wenn in derselben SG8 das CCI+Z56 (Speicher) vorhanden + 339,Speicherkapazität,SG9,QTY,,00281,,,,, + 340,Speicherkapazität,SG9,QTY,6063,00281,Z42,,Speicherkapazität,, + 341,Speicherkapazität,SG9,QTY,6060,00281,,,Menge,, + 342,Speicherkapazität,SG9,QTY,6411,00281,KWH,,Kilowattstunde,, + 343,Art und Nutzung der Technischen Ressource,SG10,,,,,,,, + 344,Art und Nutzung der Technischen Ressource,SG10,CCI,,00282,,,,, + 345,Art und Nutzung der Technischen Ressource,SG10,CCI,7059,00282,Z17,,Stromverbrauchsart,, + 346,Art und Nutzung der Technischen Ressource,SG10,CCI,7059,,Z50,,Stromerzeugungsart,, + 347,Art und Nutzung der Technischen Ressource,SG10,CCI,7059,,Z56,,Speicher,, + 348,Verbrauchsart,SG10,CAV,,00283,,,,,[446] Wenn in derselben SG8 das CCI+Z17 (Stromverbrauchsart) vorhanden + 349,Verbrauchsart,SG10,CAV,7111,00283,Z64,,Kraft/Licht,, + 350,Verbrauchsart,SG10,CAV,7111,,Z65,,Wärme,, + 351,Verbrauchsart,SG10,CAV,7111,,ZE5,,E-Mobilität,, + 352,Verbrauchsart,SG10,CAV,7111,,ZA8,,Straßenbeleuchtung,, + 353,Wärmenutzung,SG10,CAV,,00284,,,,,[239] Wenn in derselben SG10 das CCI+Z17 (Stromverbrauchsart) im CAV+Z65 (Wärme) vorhanden + 354,Wärmenutzung,SG10,CAV,7111,00284,Z56,,Speicherheizung,, + 355,Wärmenutzung,SG10,CAV,7111,,Z57,,Wärmepumpe,, + 356,Wärmenutzung,SG10,CAV,7111,,Z61,,Direktheizung,, + 357,Art der E-Mobilität,SG10,CAV,,00285,,,,,[95] Wenn in derselben SG10 das CCI+Z17 (Stromverbrauchsart) CAV+ZE5 (E-Mobilität) vorhanden + 358,Art der E-Mobilität,SG10,CAV,7111,00285,ZE6,,Wallbox,, + 359,Art der E-Mobilität,SG10,CAV,7111,,Z87,,E-Mobilitätsladesäule,, + 360,Art der E-Mobilität,SG10,CAV,7111,,ZE7,,Ladepark,, + 361,Erzeugungsart,SG10,CAV,,00286,,,,,[447] Wenn in derselben SG8 das CCI+Z50 (Stromerzeugungsart) vorhanden + 362,Erzeugungsart,SG10,CAV,7111,00286,ZF5,,Solar,, + 363,Erzeugungsart,SG10,CAV,7111,,ZF6,,Wind,, + 364,Erzeugungsart,SG10,CAV,7111,,ZG0,,Gas,, + 365,Erzeugungsart,SG10,CAV,7111,,ZG1,,Wasser,, + 366,Erzeugungsart,SG10,CAV,7111,,ZG5,,Sonstige Erzeugungsart,, + 367,Speicherart,SG10,CAV,,00287,,,,,[448] Wenn in derselben + 368,Speicherart,SG10,CAV,7111,00287,ZF7,,Wasserstoffspeicher,, + 369,Speicherart,SG10,CAV,7111,,ZF8,,Pumpspeicher,, + 370,Speicherart,SG10,CAV,7111,,ZF9,,Batteriespeicher,, + 371,Speicherart,SG10,CAV,7111,,ZG6,,Sonstige Speicherart,, + 372,Kategorie der verbrauchenden Technischen Ressource,SG10,CAV,,00288,,,,,"[446] Wenn in derselben SG8 das CCI+Z17 (Stromverbrauchsart) vorhanden + [448] Wenn in derselben SG8 das CCI+Z56 (Speicher) vorhanden" + 373,Kategorie der verbrauchenden Technischen Ressource,SG10,CAV,7111,00288,ZG8,,Technischen Ressourcefällt unter § 14a EnWG,, + 374,Kategorie der verbrauchenden Technischen Ressource,SG10,CAV,7111,,ZG9,,Technischen Ressourcefällt nicht unter § 14aEnWG,, + 375,Inbetriebsetzungsdatum der verbrauchenden Technischen Ressource nach § 14a EnWG,SG10,CAV,,00289,,,,,[461] Wenn in derselben SG10 das CCI+Z17 (Stromverbrauchsart) im CAV+ZG8 (Technischen Ressource fällt unter § 14a EnWG) vorhanden + 376,Inbetriebsetzungsdatum der verbrauchenden Technischen Ressource nach § 14a EnWG,SG10,CAV,7111,00289,ZH0,,Inbetriebsetzung der TRnach 2023,, + 377,Inbetriebsetzungsdatum der verbrauchenden Technischen Ressource nach § 14a EnWG,SG10,CAV,7111,,ZH1,,Inbetriebsetzung der TRvor 2024,, + 378,Einordnung der verbrauchenden Technischen Ressource nach § 14a EnWG mit Inbetriebsetzung vor 2024,SG10,CAV,,00290,,,,,[462] Wenn in derselben SG10 das CCI+Z17 (Stromverbrauchsart) im CAV+ZH1 (Inbetriebsetzung der TR vor 2024) vorhanden + 379,Einordnung der verbrauchenden Technischen Ressource nach § 14a EnWG mit Inbetriebsetzung vor 2024,SG10,CAV,7111,00290,ZH2,,Wechselmöglichkeit indas § 14a EnWG-Modellgem. Festlegung BK6-22-300 einmalig nochmöglich,, + 380,Einordnung der verbrauchenden Technischen Ressource nach § 14a EnWG mit Inbetriebsetzung vor 2024,SG10,CAV,7111,,ZH3,,Wechselmöglichkeit indas § 14a EnWG-Modellgem. Festlegung BK6-22-300 nicht möglich,, + 381,Einordnung der verbrauchenden Technischen Ressource nach § 14a EnWG mit Inbetriebsetzung vor 2024,SG10,CAV,7111,,ZH4,,Befristet im alten § 14aEnWG-Modell bis 2028ohneWechselmöglichkeit,, + 382,Einordnung der verbrauchenden Technischen Ressource nach § 14a EnWG mit Inbetriebsetzung vor 2024,SG10,CAV,7111,,ZH5,,Wechsel in das § 14aEnWG-Modell gem.Festlegung BK6-22-300wurde durchgeführt,, + 383,Information zu weiteren technischen Einrichtungen,SG10,,,,,,,,"[446] Wenn in derselben SG8 das CCI+Z17 (Stromverbrauchsart) vorhanden + [467] Wenn in derselben SG8 SEQ+Z52 (Daten der Technischen Ressource) das CAV+ZG8 (Technischen Ressource fällt unter §14a EnWG) vorhanden ist" + 384,Information zu weiteren technischen Einrichtungen,SG10,CCI,,00291,,,,, + 385,Information zu weiteren technischen Einrichtungen,SG10,CCI,7059,00291,Z63,,Information zu weiterentechnischenEinrichtungen,, + 386,Information zu weiteren technischen Einrichtungen,SG10,CAV,,00292,,,,, + 387,Information zu weiteren technischen Einrichtungen,SG10,CAV,7111,00292,ZH7,,Weitere technischeEinrichtungen vorhanden,, + 388,Information zu weiteren technischen Einrichtungen,SG10,CAV,7111,,ZH8,,Keine weitere technischeEinrichtung vorhanden,, + 389,Daten der Steuerbaren Ressource,SG8,,,,,,,,[205] Wenn SG5 LOC+Z19 (Steuerbare Ressource) vorhanden + 390,Daten der Steuerbaren Ressource,SG8,SEQ,,00293,,,,, + 391,Daten der Steuerbaren Ressource,SG8,SEQ,1229,00293,Z62,,Daten der Steuerbaren,, + 392,Referenz auf die ID der Steuerbaren Ressource,SG8,RFF,,00294,,,,, + 393,Referenz auf die ID der Steuerbaren Ressource,SG8,RFF,1153,00294,Z38,,Steuerbare Ressource,, + 394,Referenz auf die ID der Steuerbaren Ressource,SG8,RFF,1154,00294,,,ID der Steuerbaren Ressource,,[961] Format: SR-ID + 395,Zugeordnete Marktpartner,SG10,,,,,,,, + 396,Zugeordnete Marktpartner,SG10,CCI,,00297,,,,, + 397,Zugeordnete Marktpartner,SG10,CCI,7037,00297,ZB3,,ZugeordneterMarktpartner,, + 398,Messstellenbetreiber,SG10,CAV,,00298,,,,, + 399,Messstellenbetreiber,SG10,CAV,7111,00298,Z91,,MSB,, + 400,Messstellenbetreiber,SG10,CAV,1131,00298,,,MP-ID,, + 401,Messstellenbetreiber,SG10,CAV,7110,00298,Z39,,GrundzuständigerMessstellenbetreiber,, + 402,Messstellenbetreiber,SG10,CAV,7110,,Z40,,WettbewerblicherMessstellenbetreiber,, + 403,Messstellenbetreiber,SG10,CAV,7110,,Z41,,Auffangmessstellenbetreiber,, + 404,Daten der Messlokation,SG8,,,,,,,,"[92] Wenn Wert innerhalb SG bzw. Segment geändert wird + [345] Wenn SG5 LOC+Z17 (Messlokation) vorhanden" + 405,Daten der Messlokation,SG8,SEQ,,00306,,,,, + 406,Daten der Messlokation,SG8,SEQ,1229,00306,Z18,,Daten der Messlokation,, + 407,Referenz auf die ID der Messlokation,SG8,RFF,,00307,,,,, + 408,Referenz auf die ID der Messlokation,SG8,RFF,1153,00307,Z19,,Messlokation,, + 409,Referenz auf die ID der Messlokation,SG8,RFF,1154,00307,,,ID der Messlokation,,[951] Format: Zählpunktbezeichnung + 410,Abrechnung des Messstellenbetriebs über NNE für kME,SG8,RFF,,00309,,,,,[92] Wenn Wert innerhalb SG bzw. Segment geändert wird + 411,Abrechnung des Messstellenbetriebs über NNE für kME,SG8,RFF,1153,00309,Z05,,Abrechnung des,, + 412,Abrechnung des Messstellenbetriebs über NNE für kME,SG8,RFF,1154,00309,,,Abrechnung über NNE (Ja/Nein),, + 413,Zugeordnete Marktpartner,SG10,,,,,,,,[92] Wenn Wert innerhalb SG bzw. Segment geändert wird + 414,Zugeordnete Marktpartner,SG10,CCI,,00310,,,,, + 415,Zugeordnete Marktpartner,SG10,CCI,7037,00310,ZB3,,ZugeordneterMarktpartner,, + 416,Messstellenbetreiber,SG10,CAV,,00311,,,,, + 417,Messstellenbetreiber,SG10,CAV,7111,00311,Z91,,MSB,, + 418,Messstellenbetreiber,SG10,CAV,1131,00311,,,MP-ID,, + 419,Messstellenbetreiber,SG10,CAV,7110,00311,Z19,,Auf vertraglicherGrundlage gegenüberAnschlussnutzer /Anschlussnehmer,, + 420,Messstellenbetreiber,SG10,CAV,7110,,Z20,,In der Ausübung derWeiterverpflichtungdurch den gMSB,, + 421,Messstellenbetreiber,SG10,CAV,7110,00311,Z39,,GrundzuständigerMessstellenbetreiber,, + 422,Messstellenbetreiber,SG10,CAV,7110,,Z40,,WettbewerblicherMessstellenbetreiber,, + 423,Messstellenbetreiber,SG10,CAV,7110,,Z41,,Auffangmessstellenbetreiber,, + 424,Grundzuständiger Messstellenbetreiber,SG10,CAV,,00312,,,,, + 425,Grundzuständiger Messstellenbetreiber,SG10,CAV,7111,00312,ZF0,,gMSB,, + 426,Grundzuständiger Messstellenbetreiber,SG10,CAV,1131,00312,,,MP-ID,, + 427,Kunde des Netzbetreibers,SG12,,,,,,,,"[25] Wenn SG5 LOC+Z16 (Marktlokation) vorhanden + [92] Wenn Wert innerhalb SG bzw. Segment geändert wird + [558] Hinweis: Diese Information kann freiwillig ausgetauscht werden" + 428,Kunde des Netzbetreibers,SG12,NAD,,00527,,,,, + 429,Kunde des Netzbetreibers,SG12,NAD,3035,00527,Z25,,Kunde des NB,, + 430,Kunde des Netzbetreibers,SG12,NAD,3036,00527,,,Name,, + 431,Kunde des Netzbetreibers,SG12,NAD,3045,00527,Z01,,Struktur vonPersonennamen,, + 432,Kunde des Netzbetreibers,SG12,NAD,3045,,Z02,,Struktur derFirmenbezeichnung,, + 433,Referenz auf die ID der Marktlokation,SG12,RFF,,00528,,,,, + 434,Referenz auf die ID der Marktlokation,SG12,RFF,1153,00528,Z18,,Marktlokation,, + 435,Referenz auf die ID der Marktlokation,SG12,RFF,1154,00528,,,ID der Marktlokation,,[950] Format: Marktlokations-ID + 436,Korrespondenzanschrift des Kunde des Netzbetreibers,SG12,,,,,,,,"[25] Wenn SG5 LOC+Z16 (Marktlokation) vorhanden + [92] Wenn Wert innerhalb SG bzw. Segment geändert wird + [558] Hinweis: Diese Information kann freiwillig ausgetauscht werden" + 437,Korrespondenzanschrift des Kunde des Netzbetreibers,SG12,NAD,,00529,,,,, + 438,Korrespondenzanschrift des Kunde des Netzbetreibers,SG12,NAD,3035,00529,Z26,,Korrespondenzanschriftdes Kunden des NB,, + 439,Korrespondenzanschrift des Kunde des Netzbetreibers,SG12,NAD,3036,00529,,,Name,, + 440,Korrespondenzanschrift des Kunde des Netzbetreibers,SG12,NAD,3045,00529,Z01,,Struktur vonPersonennamen,, + 441,Korrespondenzanschrift des Kunde des Netzbetreibers,SG12,NAD,3045,,Z02,,Struktur derFirmenbezeichnung,, + 442,Korrespondenzanschrift des Kunde des Netzbetreibers,SG12,NAD,3042,00529,,,Straße und Hausnummer oderPostfach,, + 443,Korrespondenzanschrift des Kunde des Netzbetreibers,SG12,NAD,3164,00529,,,Ort,, + 444,Korrespondenzanschrift des Kunde des Netzbetreibers,SG12,NAD,3251,00529,,,Postleitzahl,,"[166] Wenn vorhanden + [268] Wenn der Code im DE3207 in der ""EDI@Energy Codeliste der europäischen Ländercodes"" in der Spalte ""PLZ vorhanden"" ein ""X"" aufgeführt ist" + 445,Korrespondenzanschrift des Kunde des Netzbetreibers,SG12,NAD,3207,00529,,,"Ländername, Code",, + 446,Referenz auf die ID der Marktlokation,SG12,RFF,,00530,,,,, + 447,Referenz auf die ID der Marktlokation,SG12,RFF,1153,00530,Z18,,Marktlokation,, + 448,Referenz auf die ID der Marktlokation,SG12,RFF,1154,00530,,,ID der Marktlokation,,[950] Format: Marktlokations-ID + 449,Anschlussnehmer,SG12,,,,,,,,"[25] Wenn SG5 LOC+Z16 (Marktlokation) vorhanden + [92] Wenn Wert innerhalb SG bzw. Segment geändert wird + [558] Hinweis: Diese Information kann freiwillig ausgetauscht werden" + 450,Anschlussnehmer,SG12,NAD,,00531,,,,, + 451,Anschlussnehmer,SG12,NAD,3035,00531,EO,,Anschlussnehmer,, + 452,Anschlussnehmer,SG12,NAD,3036,00531,,,Name,, + 453,Anschlussnehmer,SG12,NAD,3045,00531,Z01,,Struktur vonPersonennamen,, + 454,Anschlussnehmer,SG12,NAD,3045,,Z02,,Struktur derFirmenbezeichnung,, + 455,Anschlussnehmer,SG12,NAD,3042,00531,,,Straße und Hausnummer oderPostfach,, + 456,Anschlussnehmer,SG12,NAD,3164,00531,,,Ort,, + 457,Anschlussnehmer,SG12,NAD,3251,00531,,,Postleitzahl,,"[166] Wenn vorhanden + [268] Wenn der Code im DE3207 in der ""EDI@Energy Codeliste der europäischen Ländercodes"" in der Spalte ""PLZ vorhanden"" ein ""X"" aufgeführt ist" + 458,Anschlussnehmer,SG12,NAD,3207,00531,,,"Ländername, Code",, + 459,Hausverwalter,SG12,,,,,,,,"[25] Wenn SG5 LOC+Z16 (Marktlokation) vorhanden + [92] Wenn Wert innerhalb SG bzw. Segment geändert wird + [558] Hinweis: Diese Information kann freiwillig ausgetauscht werden" + 460,Hausverwalter,SG12,NAD,,00532,,,,, + 461,Hausverwalter,SG12,NAD,3035,00532,DDO,,Location manager,, + 462,Hausverwalter,SG12,NAD,3036,00532,,,Name,, + 463,Hausverwalter,SG12,NAD,3045,00532,Z01,,Struktur vonPersonennamen,, + 464,Hausverwalter,SG12,NAD,3045,,Z02,,Struktur derFirmenbezeichnung,, + 465,Hausverwalter,SG12,NAD,3042,00532,,,Straße und Hausnummer oderPostfach,, + 466,Hausverwalter,SG12,NAD,3164,00532,,,Ort,, + 467,Hausverwalter,SG12,NAD,3251,00532,,,Postleitzahl,,"[166] Wenn vorhanden + [268] Wenn der Code im DE3207 in der ""EDI@Energy Codeliste der europäischen Ländercodes"" in der Spalte ""PLZ vorhanden"" ein ""X"" aufgeführt ist" + 468,Hausverwalter,SG12,NAD,3207,00532,,,"Ländername, Code",, + 469,Marktlokationsanschrift,SG12,,,,,,,,"[25] Wenn SG5 LOC+Z16 (Marktlokation) vorhanden + [92] Wenn Wert innerhalb SG bzw. Segment geändert wird" + 470,Marktlokationsanschrift,SG12,NAD,,00535,,,,, + 471,Marktlokationsanschrift,SG12,NAD,3035,00535,DP,,Lieferanschrift,, + 472,Marktlokationsanschrift,SG12,NAD,3124,00535,,,Zusatzinformation zurIdentifizierung,, + 473,Marktlokationsanschrift,SG12,NAD,3042,00535,,,Straße und Hausnummer oderPostfach,,"[166] Wenn vorhanden + [212] Wenn im selben SG12 NAD DE3124 nicht vorhanden" + 474,Marktlokationsanschrift,SG12,NAD,3164,00535,,,Ort,, + 475,Marktlokationsanschrift,SG12,NAD,3251,00535,,,Postleitzahl,, + 476,Marktlokationsanschrift,SG12,NAD,3207,00535,,,"Ländername, Code",, + 477,Nachrichten-Endesegment,,UNT,,00540,,,,Muss, + 478,Nachrichten-Endesegment,,UNT,0074,00540,,,Anzahl der Segmente in einerNachricht,X, + 479,Nachrichten-Endesegment,,UNT,0062,00540,,,Nachrichten-Referenznummer,X, + + ''' +# --- +# name: TestCli.test_kohlrahbi_cli_with_valid_arguments[55127] + ''' + ,Segmentname,Segmentgruppe,Segment,Datenelement,Segment ID,Code,Qualifier,Beschreibung,Bedingungsausdruck,Bedingung + 0,Nachrichten-Kopfsegment,,UNH,,00003,,,,Muss, + 1,Nachrichten-Kopfsegment,,UNH,0062,00003,,,Nachrichten-Referenznummer,X, + 2,Nachrichten-Kopfsegment,,UNH,0065,00003,UTILMD,,Netzanschluss-Stammdaten,X, + 3,Nachrichten-Kopfsegment,,UNH,0052,00003,D,,Entwurfs-Version,X, + 4,Nachrichten-Kopfsegment,,UNH,0054,00003,11A,,Ausgabe 2011 - A,X, + 5,Nachrichten-Kopfsegment,,UNH,0051,00003,UN,,UN/CEFACT,X, + 6,Nachrichten-Kopfsegment,,UNH,0057,00003,Versionsnummer derzugrundeliegendenBDEW-Nachrichtenbeschreibung,,S1.1a,X, + 7,Beginn der Nachricht,,BGM,,00004,,,,Muss, + 8,Beginn der Nachricht,,BGM,1001,00004,E03,,Änderungsmeldungen,X, + 9,Beginn der Nachricht,,BGM,1004,00004,,,Dokumentennummer,X, + 10,Nachrichtendatum,,DTM,,00005,,,,Muss, + 11,Nachrichtendatum,,DTM,2005,00005,137,,Dokumenten-/Nachrichtendatum/-zeit,X, + 12,Nachrichtendatum,,DTM,2380,00005,,,"Datum oder Uhrzeit oderZeitspanne, Wert",X [931] [494],"[494] Das hier genannte Datum muss der Zeitpunkt sein, zu dem das Dokument erstellt wurde, oder ein Zeitpunkt, der davor liegt + [931] Format: ZZZ = +00" + 13,Nachrichtendatum,,DTM,2379,00005,303,,CCYYMMDDHHMMZZZ,X, + 14,MP-ID Absender,SG2,,,,,,,Muss, + 15,MP-ID Absender,SG2,NAD,,00008,,,,Muss, + 16,MP-ID Absender,SG2,NAD,3035,00008,MS,,Dokumenten-/Nachrichtenausstellerbzw. -absender,X, + 17,MP-ID Absender,SG2,NAD,3039,00008,,,MP-ID,X, + 18,MP-ID Absender,SG2,NAD,3055,00008,9,,GS1,X, + 19,MP-ID Absender,SG2,NAD,3055,,293,,"DE, BDEW(Bundesverband derEnergie- undWasserwirtschaft e.V.)",X, + 20,Ansprechpartner,SG3,,,,,,,Kann, + 21,Ansprechpartner,SG3,CTA,,00009,,,,Muss, + 22,Ansprechpartner,SG3,CTA,3139,00009,IC,,Informationskontakt,X, + 23,Ansprechpartner,SG3,CTA,3412,00009,,,Name vom Ansprechpartner,X, + 24,Kommunikationsverbindung,SG3,COM,,00010,,,,Muss, + 25,Kommunikationsverbindung,SG3,COM,3148,00010,,,Nummer / Adresse,X (([939] [321])∨ ([940] [322]))∧ [514],"[321] Wenn im DE3155 in demselben COM der Code EM vorhanden ist + [322] Wenn im DE3155 in demselben COM der Code TE / FX / AJ / AL vorhanden ist + [514] Hinweis: Es darf nur eine Information im DE3148 übermittelt werden + [939] Format: Die Zeichenkette muss die Zeichen @ und . enthalten + [940] Format: Die Zeichenkette muss mit dem Zeichen + beginnen und danach dürfen nur noch Ziffern folgen" + 26,Kommunikationsverbindung,SG3,COM,3155,00010,EM,,Elektronische Post,X [1P0..1], + 27,Kommunikationsverbindung,SG3,COM,3155,,FX,,Telefax,X [1P0..1], + 28,Kommunikationsverbindung,SG3,COM,3155,,TE,,Telefon,X [1P0..1], + 29,Kommunikationsverbindung,SG3,COM,3155,,AJ,,weiteres Telefon,X [1P0..1], + 30,Kommunikationsverbindung,SG3,COM,3155,,AL,,Handy,X [1P0..1], + 31,MP-ID Empfänger,SG2,,,,,,,Muss, + 32,MP-ID Empfänger,SG2,NAD,,00011,,,,Muss, + 33,MP-ID Empfänger,SG2,NAD,3035,00011,MR,,Nachrichtenempfänger,X, + 34,MP-ID Empfänger,SG2,NAD,3039,00011,,,MP-ID,X, + 35,MP-ID Empfänger,SG2,NAD,3055,00011,9,,GS1,X, + 36,MP-ID Empfänger,SG2,NAD,3055,,293,,"DE, BDEW(Bundesverband derEnergie- undWasserwirtschaft e.V.)",X, + 37,Vorgang,SG4,,,,,,,Muss, + 38,Vorgang,SG4,IDE,,00020,,,,Muss, + 39,Vorgang,SG4,IDE,7495,00020,24,,Transaktion,X, + 40,Vorgang,SG4,IDE,7402,00020,,,Vorgangsnummer,X, + 41,Beginn zum,SG4,DTM,,00024,,,,, + 42,Beginn zum,SG4,DTM,2005,00024,92,,Datum Vertragsbeginn,, + 43,Beginn zum,SG4,DTM,2380,00024,,,"Datum oder Uhrzeit oderZeitspanne, Wert",, + 44,Beginn zum,SG4,DTM,2379,00024,303,,CCYYMMDDHHMMZZZ,, + 45,"Änderung zum, Gültigkeit, Beginndatum",SG4,DTM,,00027,,,,, + 46,"Änderung zum, Gültigkeit, Beginndatum",SG4,DTM,2005,00027,157,,"Gültigkeit, Beginndatum",, + 47,"Änderung zum, Gültigkeit, Beginndatum",SG4,DTM,2380,00027,,,"Datum oder Uhrzeit oderZeitspanne, Wert",, + 48,"Änderung zum, Gültigkeit, Beginndatum",SG4,DTM,2379,00027,303,,CCYYMMDDHHMMZZZ,, + 49,Transaktionsgrund,SG4,STS,,00037,,,,Muss [2061],[2061] Segment bzw. Segmentgruppe ist genau einmal je SG4 IDE (Vorgang) anzugeben + 50,Transaktionsgrund,SG4,STS,9015,00037,7,,Transaktionsgrund,X, + 51,Transaktionsgrund,SG4,STS,9013,00037,ZF1,,Änderung derPrognosegrundlage,X, + 52,Status der Antwort,SG4,STS,,00039,,,,Muss [249],[249] Innerhalb eines SG4 IDE müssen alle DE1131 der SG4 STS+E01 den identischen Wert enthalten + 53,Status der Antwort,SG4,STS,9015,00039,E01,,Status der Antwort,X, + 54,Status der Antwort,SG4,STS,9013,00039,,,Code des Prüfschritts,X, + 55,Status der Antwort,SG4,STS,1131,00039,Codeliste Strom Nr.S_0009Codeliste Strom Nr.S_0010,,S_0009S_0010,X [5]X [135],"[5] Wenn MP-ID in SG2 NAD+MS (Nachrichtenabsender) in der Rolle LF + [135] Wenn MP-ID in SG2 NAD+MS (Nachrichtenabsender) in der Rolle MSB" + 56,Marktlokation,SG5,,,,,,,Muss [2061],[2061] Segment bzw. Segmentgruppe ist genau einmal je SG4 IDE (Vorgang) anzugeben + 57,Marktlokation,SG5,LOC,,00051,,,,Muss, + 58,Marktlokation,SG5,LOC,3227,00051,Z16,,Marktlokation,X, + 59,Marktlokation,SG5,LOC,3225,00051,,,ID der Marktlokation,X [950],[950] Format: Marktlokations-ID + 60,Prüfidentifikator,SG6,,,,,,,Muss, + 61,Prüfidentifikator,SG6,RFF,,00057,,,,Muss, + 62,Prüfidentifikator,SG6,RFF,1153,00057,Z13,,Prüfidentifikator,X, + 63,Prüfidentifikator,SG6,RFF,1154,00057,55126,,SDÄ Strom / Änderungder PrognosegrundlageNB an LF / MSB,, + 64,Prüfidentifikator,SG6,RFF,1154,,55127,,SDÄ Strom / Antwort aufÄnderung der,X, + 65,Referenz Vorgangsnummer (aus Anfragenachricht),SG6,,,,,,,Muss, + 66,Referenz Vorgangsnummer (aus Anfragenachricht),SG6,RFF,,00058,,,,Muss, + 67,Referenz Vorgangsnummer (aus Anfragenachricht),SG6,RFF,1153,00058,TN,,Transaktions-Referenznummer,X, + 68,Referenz Vorgangsnummer (aus Anfragenachricht),SG6,RFF,1154,00058,,,Vorgangsnummer,X, + 69,Daten der Marktlokation,SG8,,,,,,,,[2061] Segment bzw. Segmentgruppe ist genau einmal je SG4 IDE (Vorgang) anzugeben + 70,Daten der Marktlokation,SG8,SEQ,,00103,,,,, + 71,Daten der Marktlokation,SG8,SEQ,1229,00103,Z01,,Daten der Marktlokation,, + 72,Referenz auf die ID der Marktlokation,SG8,RFF,,00104,,,,, + 73,Referenz auf die ID der Marktlokation,SG8,RFF,1153,00104,Z18,,Marktlokation,, + 74,Referenz auf die ID der Marktlokation,SG8,RFF,1154,00104,,,ID der Marktlokation,,[950] Format: Marktlokations-ID + 75,Arbeit / Leistung für tagesparameterabhängige Marktlokation,SG9,,,,,,,,[101] Wenn SG10 CCI+++ZA6 (Prognosegrundlage der Marktlokation: Prognose auf Basis von Profilen) CAV+E14/ Z36 (TLP/ TEP/ TEP mit Ref. messung) in dieser SG8 vorhanden + 76,Arbeit / Leistung für tagesparameterabhängige Marktlokation,SG9,QTY,,00105,,,,, + 77,Arbeit / Leistung für tagesparameterabhängige Marktlokation,SG9,QTY,6063,00105,Z10,,Leistung derMarktlokation,, + 78,Arbeit / Leistung für tagesparameterabhängige Marktlokation,SG9,QTY,6063,,265,,VeranschlagteJahresmenge Gesamt/Jahresverbrauchsprognose für spezifische Arbeitfürtagesparameterabhängige Marktlokation,, + 79,Arbeit / Leistung für tagesparameterabhängige Marktlokation,SG9,QTY,6063,,Z08,,"Angepasste elektrischeArbeit nach Anhang Dder VDN-Richtlinie""Lastprofile fürunterbrechbareVerbrauchseinrichtungen""",,[102] Wenn SG10 CCI+++ZA6 (Prognosegrundlage der Marktlokation: Prognose auf Basis von Profilen) CAV+Z36 (TEP mit Ref.messung) in dieser SG8 vorhanden + 80,Arbeit / Leistung für tagesparameterabhängige Marktlokation,SG9,QTY,6060,00105,,,Menge,,[902] Format: Möglicher Wert: + 81,Arbeit / Leistung für tagesparameterabhängige Marktlokation,SG9,QTY,6411,00105,Z16,,kWh/K (Kilowatt-Stunde/Kelvin),, + 82,Arbeit / Leistung für tagesparameterabhängige Marktlokation,SG9,QTY,6411,,KWH,,Kilowattstunde,, + 83,Arbeit / Leistung für tagesparameterabhängige Marktlokation,SG9,QTY,6411,,KWT,,Kilowatt,,"[103] Wenn SG9 QTY+265 (Arbeit / Leistung für tagesparameterabhängig e Marktlokation: Veranschlagte Jahresmenge Gesamt) in dieser SG8 vorhanden + [104] Wenn SG9 QTY+Z08 (Arbeit / Leistung für tagesparameterabhängige Marktlokation: angepasste elektrische Arbeit nach Anhang D) in dieser SG8 vorhanden + [105] Wenn SG9 QTY+Z10 (Arbeit / Leistung für tagesparameterabhängige Marktlokation: Leistung der Marktlokation) in dieser SG8 vorhanden" + 84,Veranschlagte Jahresmenge gesamt,SG9,,,,,,,,"[106] Wenn in dieser SG8 SEQ+Z01 SG10 CCI+++ZA6 (Prognosegrundlage der Marktlokation: Prognose auf Basis von Profilen) CAV+E02 (SLP/SEP) vorhanden + [241] Wenn MP-ID in SG2 NAD+MR (Nachrichtenempfänger) in der Rolle MSB + [248] Wenn die Inbetriebnahme der verbrauchenden Marktlokation innerhalb der letzten drei Jahre war und die Energie der Marktlokation mit iMS ausgestatteten Messlokationen erfolgt " + 85,Veranschlagte Jahresmenge gesamt,SG9,QTY,,00106,,,,, + 86,Veranschlagte Jahresmenge gesamt,SG9,QTY,6063,00106,31,,VeranschlagteJahresmenge Gesamt,, + 87,Veranschlagte Jahresmenge gesamt,SG9,QTY,6060,00106,,,Mengenangabe,,"[902] Format: Möglicher Wert: ≥ 0 + [937] Format: keine Nachkommastelle" + 88,Veranschlagte Jahresmenge gesamt,SG9,QTY,6411,00106,KWH,,Kilowattstunde,, + 89,Lieferrichtung,SG10,,,,,,,, + 90,Lieferrichtung,SG10,CCI,,00110,,,,, + 91,Lieferrichtung,SG10,CCI,7059,00110,Z30,,Lieferrichtung,, + 92,Lieferrichtung,SG10,CCI,7037,00110,Z06,,Erzeugung,, + 93,Lieferrichtung,SG10,CCI,7037,,Z07,,Verbrauch,, + 94,Regelzone,SG10,,,,,,,,[4] Wenn MP-ID in SG2 NAD+MR (Nachrichtenempfänger) in der Rolle LF + 95,Regelzone,SG10,CCI,,00116,,,,, + 96,Regelzone,SG10,CCI,7059,00116,Z18,,Regelzone,, + 97,Regelzone,SG10,CCI,7037,00116,,,Regelzone,, + 98,Bilanzierungsgebiet,SG10,,,,,,,,[4] Wenn MP-ID in SG2 NAD+MR (Nachrichtenempfänger) in der Rolle LF + 99,Bilanzierungsgebiet,SG10,CCI,,00118,,,,, + 100,Bilanzierungsgebiet,SG10,CCI,7059,00118,Z20,,Bilanzierungsgebiet,, + 101,Bilanzierungsgebiet,SG10,CCI,7037,00118,,,Bilanzierungsgebiet,, + 102,Verbrauchsaufteilung für temperaturabhängige Marktlokation,SG10,,,,,,,,"[4] Wenn MP-ID in SG2 NAD+MR (Nachrichtenempfänger) in der Rolle LF + [89] Wenn im SG8 SEQ+Z01 (Daten der Marktlokation) das SG10 CCI+++ZA6 (Prognosegrundlage der Marktlokation: Prognose auf Basis von Profilen) CAV+E14 (TLP/TEP) vorhanden + [106] Wenn in dieser SG8 SEQ+Z01 SG10 CCI+++ZA6 (Prognosegrundlage der Marktlokation: Prognose auf Basis von Profilen) CAV+E02 (SLP/SEP) vorhanden" + 103,Verbrauchsaufteilung für temperaturabhängige Marktlokation,SG10,CCI,,00119,,,,, + 104,Verbrauchsaufteilung für temperaturabhängige Marktlokation,SG10,CCI,7037,00119,E17,,Verbrauchsaufteilung (in%) fürtemperaturabhängigeMarktlokation,, + 105,Verbrauchsaufteilung für temperaturabhängige Marktlokation,SG10,CAV,,00120,,,,, + 106,Verbrauchsaufteilung für temperaturabhängige Marktlokation,SG10,CAV,7111,00120,Z22,,Verbrauchsaufteilung in%,, + 107,Verbrauchsaufteilung für temperaturabhängige Marktlokation,SG10,CAV,7110,00120,,,Verbrauchsaufteilung in %,,[902] Format: Möglicher Wert: ≥ 0 + 108,Zeitreihentyp,SG10,,,,,,,,"[4] Wenn MP-ID in SG2 NAD+MR (Nachrichtenempfänger) in der Rolle LF + [90] Wenn SG10 CCI+++ZA6 (Prognosegrundlage der Marktlokation: Prognose auf Basis von Profilen) einmal mit CAV+E14 (TLP/TEP) und einmal mit CAV+E02 (SLP/SEP) in dieser SG8 vorhanden + [2061] Segment bzw. Segmentgruppe ist genau einmal je SG4 IDE (Vorgang) anzugeben + [2096] Segmentgruppe ist genau zweimal je SG4 IDE anzugeben" + 109,Zeitreihentyp,SG10,CCI,,00121,,,,, + 110,Zeitreihentyp,SG10,CCI,7059,00121,15,,Struktur,, + 111,Zeitreihentyp,SG10,CCI,7037,00121,Z21,,Summenzeitreihentyp,, + 112,Zeitreihentyp,SG10,CAV,,00122,,,,, + 113,Zeitreihentyp,SG10,CAV,7111,00122,,,Code des Zeitreihentyps,, + 114,Aggregationsverantwortung in MaBiS,SG10,,,,,,,, + 115,Aggregationsverantwortung in MaBiS,SG10,CCI,,00128,,,,, + 116,Aggregationsverantwortung in MaBiS,SG10,CCI,7059,00128,6,,Verantwortlicher,, + 117,Aggregationsverantwortung in MaBiS,SG10,CCI,7037,00128,ZA8,,NB,, + 118,Aggregationsverantwortung in MaBiS,SG10,CCI,7037,,ZA9,,ÜNB,, + 119,Prognosegrundlage der Marktlokation,SG10,,,,,,,, + 120,Prognosegrundlage der Marktlokation,SG10,CCI,,00130,,,,, + 121,Prognosegrundlage der Marktlokation,SG10,CCI,7037,00130,ZC0,,Prognose auf Basis vonWerten,, + 122,Prognosegrundlage der Marktlokation,SG10,CCI,7037,,ZA6,,Prognose auf Basis vonProfilen,, + 123,Details der Prognosegrundlage,SG10,CAV,,00131,,,,,"[21] Wenn SG10 CCI+++ZA6 (Prognose auf Basis von Profilen) in dieser SG8 vorhanden + [90] Wenn SG10 CCI+++ZA6 (Prognosegrundlage der Marktlokation: Prognose auf Basis von Profilen) einmal mit CAV+E14 (TLP/TEP) und einmal mit CAV+E02 (SLP/SEP) in dieser SG8 vorhanden + [2182] Segmentgruppe ist genau einmal je SG8 SEQ+Z01 (Daten der Marktlokation) anzugeben + [2183] Segmentgruppe ist genau zweimal je SG8 SEQ+Z01 (Daten der Marktlokation) anzugeben" + 124,Details der Prognosegrundlage,SG10,CAV,7111,00131,E02,,SLP/SEP,, + 125,Details der Prognosegrundlage,SG10,CAV,7111,,E14,,TLP/TEP,, + 126,Details der Prognosegrundlage,SG10,CAV,7111,,Z36,,TEP mitReferenzmessung,, + 127,Wahlrecht der Prognosegrundlage der Marktlokation,SG10,,,,,,,,"[4] Wenn MP-ID in SG2 NAD+MR (Nachrichtenempfänger) in der Rolle LF + [20] Wenn SG8 SEQ+Z01 (Daten der Marktlokation) SG10 CCI+Z30++Z07 (Verbrauch) vorhanden + [244] Wenn SG10 CCI+6++ZA9 (Aggreg.verantw. ÜNB) in dieser SG8 vorhanden" + 128,Wahlrecht der Prognosegrundlage der Marktlokation,SG10,CCI,,00134,,,,, + 129,Wahlrecht der Prognosegrundlage der Marktlokation,SG10,CCI,7037,00134,Z84,,Wahlrecht derPrognosegrundlage,, + 130,Wahlrecht der Prognosegrundlage der Marktlokation,SG10,CAV,,00135,,,,, + 131,Wahlrecht der Prognosegrundlage der Marktlokation,SG10,CAV,7111,00135,Z54,,Wahlrecht durch LFgegeben,, + 132,Wahlrecht der Prognosegrundlage der Marktlokation,SG10,CAV,7111,,ZE2,,Wahlrecht durch LF nichtgegeben,, + 133,Grund für nicht vorhandenes Wahlrecht der Prognosegrundlage der Marktlokation,SG10,CAV,,00136,,,,,[247] Wenn CAV+ZE2 (Wahlrecht durch LF nicht gegeben) vorhanden + 134,Grund für nicht vorhandenes Wahlrecht der Prognosegrundlage der Marktlokation,SG10,CAV,7111,00136,Z55,,Wahlrecht nichtvorhanden wegenVerbrauch > 10.000kWh/a,, + 135,Grund für nicht vorhandenes Wahlrecht der Prognosegrundlage der Marktlokation,SG10,CAV,7111,,ZC1,,Wahlrecht nichtvorhanden wegenEigenverbrauch,, + 136,Grund für nicht vorhandenes Wahlrecht der Prognosegrundlage der Marktlokation,SG10,CAV,7111,,ZD2,,Wahlrecht nichtvorhanden wegentagesparameterabhängigem Verbrauch,, + 137,Grund für nicht vorhandenes Wahlrecht der Prognosegrundlage der Marktlokation,SG10,CAV,7111,,ZE3,,Wahlrecht nichtvorhanden wegen § 14aEnWG,, + 138,Abwicklungsmodell,SG10,,,,,,,,[20] Wenn SG8 SEQ+Z01 (Daten der Marktlokation) SG10 CCI+Z30++Z07 (Verbrauch) vorhanden + 139,Abwicklungsmodell,SG10,CCI,,00153,,,,, + 140,Abwicklungsmodell,SG10,CCI,7059,00153,ZA2,,Abwicklungsmodell,, + 141,Abwicklungsmodell,SG10,CCI,7037,00153,ZE9,,"Modell 1 ""Bilanzierungan der Marktlokation""",, + 142,Abwicklungsmodell,SG10,CCI,7037,,ZF0,,"Modell 2 ""Bilanzierungim Bilanzierungsgebiet(BG) des LPB""",, + 143,Profildaten,SG8,,,,,,,,[119] Wenn in der SG8 SEQ+Z01 SG10 CCI+++ZA6 (Prognosegrundlage der Marktlokation: Prognose auf Basis von Profilen) CAV+E02 (SLP/SEP) vorhanden + 144,Profildaten,SG8,SEQ,,00376,,,,, + 145,Profildaten,SG8,SEQ,1229,00376,Z21,,Profildaten,, + 146,Referenz auf die ID der Marktlokation,SG8,RFF,,00378,,,,, + 147,Referenz auf die ID der Marktlokation,SG8,RFF,1153,00378,Z18,,Marktlokation,, + 148,Referenz auf die ID der Marktlokation,SG8,RFF,1154,00378,,,ID einer Marktlokation,,[950] Format: Marktlokations-ID + 149,Normiertes Profil,SG10,,,,,,,, + 150,Normiertes Profil,SG10,CCI,,00380,,,,, + 151,Normiertes Profil,SG10,CCI,7059,00380,Z02,,Standardlastprofil,, + 152,Normiertes Profil,SG10,CCI,7059,,Z04,,Standardeinspeiseprofil,,"[20] Wenn SG8 SEQ+Z01 (Daten der Marktlokation) SG10 CCI+Z30++Z07 (Verbrauch) vorhanden + [54] Wenn SG8 SEQ+Z01 (Daten der Marktlokation) SG10 CCI+Z30++Z06 (Lieferrichtung: Erzeugung) vorhanden" + 153,Normiertes Profil,SG10,CCI,7037,00380,E01,,synthetisches Verfahren,, + 154,Normiertes Profil,SG10,CCI,7037,,Z10,,analytisches Verfahren,,[332] Wenn im SG8 SEQ+Z01 (Daten der Marktlokation) das SG10 CCI+6++ZA9 (Aggreg. verantw. ÜNB) nicht vorhanden + 155,Normiertes Profil,SG10,CAV,,00381,,,,, + 156,Normiertes Profil,SG10,CAV,7111,00381,,,Code des Normierten Profils,, + 157,Profilschardaten,SG8,,,,,,,,[89] Wenn im SG8 SEQ+Z01 (Daten der Marktlokation) das SG10 CCI+++ZA6 (Prognosegrundlage der Marktlokation: Prognose auf Basis von Profilen) CAV+E14 (TLP/TEP) vorhanden + 158,Profilschardaten,SG8,SEQ,,00387,,,,, + 159,Profilschardaten,SG8,SEQ,1229,00387,Z08,,Profilschardaten,, + 160,Referenz auf die ID der Marktlokation,SG8,RFF,,00389,,,,, + 161,Referenz auf die ID der Marktlokation,SG8,RFF,1153,00389,Z18,,Marktlokation,, + 162,Referenz auf die ID der Marktlokation,SG8,RFF,1154,00389,,,ID einer Marktlokation,,[950] Format: Marktlokations-ID + 163,Profilschar,SG10,,,,,,,, + 164,Profilschar,SG10,CCI,,00397,,,,, + 165,Profilschar,SG10,CCI,7037,00397,Z12,,Profilschar,, + 166,Profilschar,SG10,CAV,,00398,,,,, + 167,Profilschar,SG10,CAV,7111,00398,,,Code der Profilschar,, + 168,Normiertes Profil,SG10,,,,,,,, + 169,Normiertes Profil,SG10,CCI,,00399,,,,, + 170,Normiertes Profil,SG10,CCI,7059,00399,Z03,,tagesparameterabhängiges Lastprofil,, + 171,Normiertes Profil,SG10,CCI,7059,,Z05,,tagesparameterabhängiges Einspeiseprofil,,"[20] Wenn SG8 SEQ+Z01 (Daten der Marktlokation) SG10 CCI+Z30++Z07 (Verbrauch) vorhanden + [54] Wenn SG8 SEQ+Z01 (Daten der Marktlokation) SG10 CCI+Z30++Z06 (Lieferrichtung: Erzeugung) vorhanden" + 172,Normiertes Profil,SG10,CCI,7037,00399,E01,,synthetisches Verfahren,, + 173,Normiertes Profil,SG10,CCI,7037,,Z10,,analytisches Verfahren,, + 174,Normiertes Profil,SG10,CAV,,00400,,,,, + 175,Normiertes Profil,SG10,CAV,7111,00400,,,Code des Normierten Profils,, + 176,Klimazone / Temperaturmessstelle,SG10,,,,,,,, + 177,Klimazone / Temperaturmessstelle,SG10,CCI,,00403,,,,, + 178,Klimazone / Temperaturmessstelle,SG10,CCI,7059,00403,Z99,,Messstelle desTagesparameters(derzeit ist nur dieTemperatur ein erlaubterTagesparameter),, + 179,Klimazone / Temperaturmessstelle,SG10,CCI,7059,,ZA0,,Klimazone desTagesparameters(derzeit istTagesparameter),, + 180,Klimazone / Temperaturmessstelle,SG10,CCI,7037,00403,,,ID Klimazone /Temperaturmessstelle,, + 181,Klimazone / Temperaturmessstelle,SG10,CCI,1131,00403,,,Dienstanbieter,,[58] Wenn in diesem CCI das DE3055 mit dem Code 293 vorhanden + 182,Klimazone / Temperaturmessstelle,SG10,CCI,3055,00403,89,,Vergeben vom Händler(hier Netzbetreiber),, + 183,Klimazone / Temperaturmessstelle,SG10,CCI,3055,,293,,"DE, BDEW(Bundesverband derEnergie- undWasserwirtschaft e.V.)",, + 184,Referenzprofildaten,SG8,,,,,,,,[54] Wenn SG8 SEQ+Z01 (Daten der Marktlokation) SG10 CCI+Z30++Z06 (Lieferrichtung: Erzeugung) vorhanden + 185,Referenzprofildaten,SG8,SEQ,,00411,,,,, + 186,Referenzprofildaten,SG8,SEQ,1229,00411,Z38,,Referenzprofildaten,, + 187,Referenz auf die ID der Marktlokation,SG8,RFF,,00413,,,,, + 188,Referenz auf die ID der Marktlokation,SG8,RFF,1153,00413,Z18,,Marktlokation,, + 189,Referenz auf die ID der Marktlokation,SG8,RFF,1154,00413,,,ID einer Marktlokation,,[950] Format: Marktlokations-ID + 190,Referenzprofil,SG10,,,,,,,, + 191,Referenzprofil,SG10,CCI,,00415,,,,, + 192,Referenzprofil,SG10,CCI,7059,00415,Z05,,tagesparameterabhängiges Einspeiseprofil,, + 193,Referenzprofil,SG10,CAV,,00416,,,,, + 194,Referenzprofil,SG10,CAV,7111,00416,,,Code des Referenzprofils,, + 195,Nachrichten-Endesegment,,UNT,,00540,,,,Muss, + 196,Nachrichten-Endesegment,,UNT,0074,00540,,,Anzahl der Segmente in einerNachricht,X, + 197,Nachrichten-Endesegment,,UNT,0062,00540,,,Nachrichten-Referenznummer,X, + + ''' +# --- +# name: TestCli.test_kohlrahbi_cli_with_valid_arguments[55147] + ''' + ,Segmentname,Segmentgruppe,Segment,Datenelement,Segment ID,Code,Qualifier,Beschreibung,Bedingungsausdruck,Bedingung + 0,Nachrichten-Kopfsegment,,UNH,,00003,,,,Muss, + 1,Nachrichten-Kopfsegment,,UNH,0062,00003,,,Nachrichten-Referenznummer,X, + 2,Nachrichten-Kopfsegment,,UNH,0065,00003,UTILMD,,Netzanschluss-Stammdaten,X, + 3,Nachrichten-Kopfsegment,,UNH,0052,00003,D,,Entwurfs-Version,X, + 4,Nachrichten-Kopfsegment,,UNH,0054,00003,11A,,Ausgabe 2011 - A,X, + 5,Nachrichten-Kopfsegment,,UNH,0051,00003,UN,,UN/CEFACT,X, + 6,Nachrichten-Kopfsegment,,UNH,0057,00003,Versionsnummer derzugrundeliegendenBDEW-Nachrichtenbeschreibung,,S1.1a,X, + 7,Beginn der Nachricht,,BGM,,00004,,,,Muss, + 8,Beginn der Nachricht,,BGM,1001,00004,E03,,Änderungsmeldungen,X, + 9,Beginn der Nachricht,,BGM,1004,00004,,,Dokumentennummer,X, + 10,Nachrichtendatum,,DTM,,00005,,,,Muss, + 11,Nachrichtendatum,,DTM,2005,00005,137,,Dokumenten-/Nachrichtendatum/-zeit,X, + 12,Nachrichtendatum,,DTM,2380,00005,,,"Datum oder Uhrzeit oderZeitspanne, Wert",X [931][494],"[494] Das hier genannte Datum muss der Zeitpunkt sein, zu dem das Dokument erstellt wurde, oder ein Zeitpunkt, der davor liegt + [931] Format: ZZZ = +00" + 13,Nachrichtendatum,,DTM,2379,00005,303,,CCYYMMDDHHMMZZZ,X, + 14,MP-ID Absender,SG2,,,,,,,Muss, + 15,MP-ID Absender,SG2,NAD,,00008,,,,Muss, + 16,MP-ID Absender,SG2,NAD,3035,00008,MS,,Dokumenten-/Nachrichtenausstellerbzw. -absender,X, + 17,MP-ID Absender,SG2,NAD,3039,00008,,,MP-ID,X, + 18,MP-ID Absender,SG2,NAD,3055,00008,9,,GS1,X, + 19,MP-ID Absender,SG2,NAD,3055,,293,,"DE, BDEW(Bundesverband derEnergie- undWasserwirtschaft e.V.)",X, + 20,Ansprechpartner,SG3,,,,,,,Kann, + 21,Ansprechpartner,SG3,CTA,,00009,,,,Muss, + 22,Ansprechpartner,SG3,CTA,3139,00009,IC,,Informationskontakt,X, + 23,Ansprechpartner,SG3,CTA,3412,00009,,,Name vom Ansprechpartner,X, + 24,Kommunikationsverbindung,SG3,COM,,00010,,,,Muss, + 25,Kommunikationsverbindung,SG3,COM,3148,00010,,,Nummer / Adresse,X (([939][321]) ∨([940][322])) ∧[514],"[321] Wenn im DE3155 in demselben COM der Code EM vorhanden ist + [322] Wenn im DE3155 in demselben COM der Code TE / FX / AJ / AL vorhanden ist + [514] Hinweis: Es darf nur eine Information im DE3148 übermittelt werden + [939] Format: Die Zeichenkette muss die Zeichen @ und . enthalten + [940] Format: Die Zeichenkette muss mit dem Zeichen + beginnen und danach dürfen nur noch Ziffern folgen" + 26,Kommunikationsverbindung,SG3,COM,3155,00010,EM,,Elektronische Post,X [1P0..1], + 27,Kommunikationsverbindung,SG3,COM,3155,,FX,,Telefax,X [1P0..1], + 28,Kommunikationsverbindung,SG3,COM,3155,,TE,,Telefon,X [1P0..1], + 29,Kommunikationsverbindung,SG3,COM,3155,,AJ,,weiteres Telefon,X [1P0..1], + 30,Kommunikationsverbindung,SG3,COM,3155,,AL,,Handy,X [1P0..1], + 31,MP-ID Empfänger,SG2,,,,,,,Muss, + 32,MP-ID Empfänger,SG2,NAD,,00011,,,,Muss, + 33,MP-ID Empfänger,SG2,NAD,3035,00011,MR,,Nachrichtenempfänger,X, + 34,MP-ID Empfänger,SG2,NAD,3039,00011,,,MP-ID,X, + 35,MP-ID Empfänger,SG2,NAD,3055,00011,9,,GS1,X, + 36,MP-ID Empfänger,SG2,NAD,3055,,293,,"DE, BDEW(Bundesverband derEnergie- undWasserwirtschaft e.V.)",X, + 37,Vorgang,SG4,,,,,,,Muss, + 38,Vorgang,SG4,IDE,,00020,,,,Muss, + 39,Vorgang,SG4,IDE,7495,00020,24,,Transaktion,X, + 40,Vorgang,SG4,IDE,7402,00020,,,Vorgangsnummer,X, + 41,Beginn zum,SG4,DTM,,00024,,,,Muss, + 42,Beginn zum,SG4,DTM,2005,00024,92,,Datum Vertragsbeginn,X, + 43,Beginn zum,SG4,DTM,2380,00024,,,"Datum oder Uhrzeit oderZeitspanne, Wert",X [UB1] ∧[528],[528] Hinweis: Es ist das Datum/ Daten aus der Anfrage zu verwenden + 44,Beginn zum,SG4,DTM,2379,00024,303,,CCYYMMDDHHMMZZZ,X, + 45,"Änderung zum, Gültigkeit, Beginndatum",SG4,DTM,,00027,,,,Muss, + 46,"Änderung zum, Gültigkeit, Beginndatum",SG4,DTM,2005,00027,157,,"Gültigkeit, Beginndatum",X, + 47,"Änderung zum, Gültigkeit, Beginndatum",SG4,DTM,2380,00027,,,"Datum oder Uhrzeit oderZeitspanne, Wert",X [UB1] ∧[528],[528] Hinweis: Es ist das Datum/ Daten aus der Anfrage zu verwenden + 48,"Änderung zum, Gültigkeit, Beginndatum",SG4,DTM,2379,00027,303,,CCYYMMDDHHMMZZZ,X, + 49,Transaktionsgrund,SG4,STS,,00037,,,,Muss [2061],[2061] Segment bzw. Segmentgruppe ist genau einmal je SG4 IDE (Vorgang) anzugeben + 50,Transaktionsgrund,SG4,STS,9015,00037,7,,Transaktionsgrund,X, + 51,Transaktionsgrund,SG4,STS,9013,00037,ZF5,,Anfrage an MSB mitAbhängigkeiten,X, + 52,Status der Antwort,SG4,STS,,00039,,,,,[249] Innerhalb eines SG4 IDE müssen alle DE1131 der SG4 STS+E01 den identischen Wert enthalten + 53,Status der Antwort,SG4,STS,9015,00039,E01,,Status der Antwort,, + 54,Status der Antwort,SG4,STS,9013,00039,,,Code des Prüfschritts,, + 55,Status der Antwort,SG4,STS,1131,00039,Codeliste Strom Nr.S_0038,,S_0038,, + 56,Netzlokation,SG5,,,,,,,Muss [2061]∧ [298] ∧[299] ∧[347] ∧[348] ∧[349],"[298] Wenn SG5 LOC+Z20 (Technische Ressource) nicht vorhanden + [299] Wenn SG5 LOC+Z19 (Steuerbare Ressource) nicht vorhanden " + 57,Netzlokation,SG5,LOC,,00050,,,,Muss, + 58,Netzlokation,SG5,LOC,3227,00050,Z18,,Netzlokation,X, + 59,Netzlokation,SG5,LOC,3225,00050,,,ID der Netzlokation,X [960],[960] Format: Netzlokations-ID + 60,Marktlokation,SG5,,,,,,,Muss [2061]∧ [297] ∧[298] ∧[299] ∧[348] ∧[349],"[297] Wenn SG5 LOC+Z18 (Netzlokation) nicht vorhanden + [298] Wenn SG5 LOC+Z20 (Technische Ressource) nicht vorhanden + [299] Wenn SG5 LOC+Z19 (Steuerbare Ressource) nicht vorhanden + [348] Wenn SG5 LOC+Z21 (Tranche) nicht vorhanden + [349] Wenn SG5 LOC+Z17 (Messlokation) nicht vorhanden + [2061] Segment bzw. Segmentgruppe ist genau einmal je SG4 IDE (Vorgang) anzugeben" + 61,Marktlokation,SG5,LOC,,00051,,,,Muss, + 62,Marktlokation,SG5,LOC,3227,00051,Z16,,Marktlokation,X, + 63,Marktlokation,SG5,LOC,3225,00051,,,ID der Marktlokation,X [950],[950] Format: Marktlokations-ID + 64,Technische Ressource,SG5,,,,,,,Muss [2061]∧ [297] ∧[299] ∧[347] ∧[348] ∧[349],"[297] Wenn SG5 LOC+Z18 (Netzlokation) nicht vorhanden + [299] Wenn SG5 LOC+Z19 (Steuerbare Ressource) nicht vorhanden + [347] Wenn SG5 LOC+Z16 (Marktlokation) nicht vorhanden + [348] Wenn SG5 LOC+Z21 (Tranche) nicht vorhanden + [349] Wenn SG5 LOC+Z17 (Messlokation) nicht vorhanden + [2061] Segment bzw. Segmentgruppe ist genau einmal je SG4 IDE (Vorgang) anzugeben" + 65,Technische Ressource,SG5,LOC,,00052,,,,Muss, + 66,Technische Ressource,SG5,LOC,3227,00052,Z20,,Technische Ressource,X, + 67,Technische Ressource,SG5,LOC,3225,00052,,,ID der Technischen Ressource,X [922],[922] Format: TR-ID + 68,Steuerbare Ressource,SG5,,,,,,,Muss [2061]∧ [297] ∧[298] ∧[347] ∧[348] ∧[349],"[297] Wenn SG5 LOC+Z18 (Netzlokation) nicht vorhanden + [298] Wenn SG5 LOC+Z20 (Technische Ressource) nicht vorhanden + [347] Wenn SG5 LOC+Z16 (Marktlokation) nicht vorhanden + [348] Wenn SG5 LOC+Z21 (Tranche) nicht vorhanden + [349] Wenn SG5 LOC+Z17 (Messlokation) nicht vorhanden " + 69,Steuerbare Ressource,SG5,LOC,,00053,,,,Muss, + 70,Steuerbare Ressource,SG5,LOC,3227,00053,Z19,,Steuerbare Ressource,X, + 71,Steuerbare Ressource,SG5,LOC,3225,00053,,,ID der Steuerbaren Ressource,X [961],[961] Format: SR-ID + 72,Tranche,SG5,,,,,,,Muss [2061]∧ [297] ∧[298] ∧[299] ∧[347] ∧[349],"[297] Wenn SG5 LOC+Z18 (Netzlokation) nicht vorhanden + [298] Wenn SG5 LOC+Z20 (Technische Ressource) nicht vorhanden + [299] Wenn SG5 LOC+Z19 (Steuerbare Ressource) nicht vorhanden + [347] Wenn SG5 LOC+Z16 (Marktlokation) nicht vorhanden + [349] Wenn SG5 LOC+Z17 (Messlokation) nicht vorhanden + [2061] Segment bzw. Segmentgruppe ist genau einmal je SG4 IDE (Vorgang) anzugeben" + 73,Tranche,SG5,LOC,,00054,,,,Muss, + 74,Tranche,SG5,LOC,3227,00054,Z21,,Tranche,X, + 75,Tranche,SG5,LOC,3225,00054,,,ID der Tranche,X [950],[950] Format: Marktlokations-ID + 76,Messlokation,SG5,,,,,,,Muss [2061]∧ [297] ∧[298] ∧[299] ∧[347] ∧[348],"[297] Wenn SG5 LOC+Z18 (Netzlokation) nicht vorhanden + [298] Wenn SG5 LOC+Z20 (Technische Ressource) nicht vorhanden + [299] Wenn SG5 LOC+Z19 (Steuerbare" + 77,Messlokation,SG5,LOC,,00055,,,,Muss, + 78,Messlokation,SG5,LOC,3227,00055,Z17,,Messlokation,X, + 79,Messlokation,SG5,LOC,3225,00055,,,ID der Messlokation,X [951],[951] Format: Zählpunktbezeichnung + 80,Prüfidentifikator,SG6,,,,,,,Muss, + 81,Prüfidentifikator,SG6,RFF,,00057,,,,Muss, + 82,Prüfidentifikator,SG6,RFF,1153,00057,Z13,,Prüfidentifikator,X, + 83,Prüfidentifikator,SG6,RFF,1154,00057,55147,,SDÄ Strom / Anfrage anMSB mit AbhängigkeitenNB [Verteiler] an MSB,X, + 84,Prüfidentifikator,SG6,RFF,1154,,55148,,SDÄ Strom / Anfrage anMSB mit AbhängigkeitenNB [Berechtigt] an MSB,, + 85,Prüfidentifikator,SG6,RFF,1154,,55149,,SDÄ Strom / Antwort aufAnfrage an MSB mitAbhängigkeiten MSB anNB,, + 86,Referenz Vorgangsnummer (aus Anfragenachricht),SG6,,,,,,,, + 87,Referenz Vorgangsnummer (aus Anfragenachricht),SG6,RFF,,00058,,,,, + 88,Referenz Vorgangsnummer (aus Anfragenachricht),SG6,RFF,1153,00058,TN,,Transaktions-Referenznummer,, + 89,Referenz Vorgangsnummer (aus Anfragenachricht),SG6,RFF,1154,00058,,,Vorgangsnummer,, + 90,Daten der Netzlokation,SG8,,,,,,,Muss [294],[294] Wenn SG5 LOC+Z18 (Netzlokation) vorhanden + 91,Daten der Netzlokation,SG8,SEQ,,00078,,,,Muss, + 92,Daten der Netzlokation,SG8,SEQ,1229,00078,Z51,,Daten der Netzlokation,X, + 93,Referenz auf die ID der Netzlokation,SG8,RFF,,00079,,,,Muss, + 94,Referenz auf die ID der Netzlokation,SG8,RFF,1153,00079,Z32,,Netzlokation,X, + 95,Referenz auf die ID der Netzlokation,SG8,RFF,1154,00079,,,ID der Netzlokation,X [960],[960] Format: Netzlokations-ID + 96,Steuerkanal,SG10,,,,,,,Muss, + 97,Steuerkanal,SG10,CCI,,00080,,,,Muss, + 98,Steuerkanal,SG10,CCI,7059,00080,Z49,,Steuerkanal,X, + 99,Steuerkanal,SG10,CCI,7037,00080,ZF2,,Kein Steuerkanalvorhanden,X, + 100,Steuerkanal,SG10,CCI,7037,,ZF3,,Steuerkanal vorhanden,X, + 101,OBIS-Daten der Netzlokation,SG8,,,,,,,Kann [294]∧ [343],"[166] Wenn vorhanden + [294] Wenn SG5 LOC+Z18 (Netzlokation) vorhanden + [343] Wenn DTM+157 (Änderung zum) im DE2380 ≥ 202312312300?+00" + 102,OBIS-Daten der Netzlokation,SG8,SEQ,,00088,,,,Muss, + 103,OBIS-Daten der Netzlokation,SG8,SEQ,1229,00088,Z57,,OBIS-Daten derNetzlokation,X, + 104,Referenz auf die ID der Netzlokation,SG8,RFF,,00089,,,,Muss, + 105,Referenz auf die ID der Netzlokation,SG8,RFF,1153,00089,Z32,,Netzlokation,X, + 106,Referenz auf die ID der Netzlokation,SG8,RFF,1154,00089,,,ID der Netzlokation,X [960],[960] Format: Netzlokations-ID + 107,OBIS-Kennzahl der Netzlokation,SG8,PIA,,00090,,,,Muss, + 108,OBIS-Kennzahl der Netzlokation,SG8,PIA,4347,00090,5,,Produktidentifikation,X, + 109,OBIS-Kennzahl der Netzlokation,SG8,PIA,7140,00090,,,OBIS-Kennzahl der Netzlokation,X, + 110,OBIS-Kennzahl der Netzlokation,SG8,PIA,7143,00090,SRW,,OBIS-Kennzahl,X, + 111,Produkt-Daten für Netzbetreiber relevant,SG10,,,,,,,Muss, + 112,Produkt-Daten für Netzbetreiber relevant,SG10,CCI,,00091,,,,Muss, + 113,Produkt-Daten für Netzbetreiber relevant,SG10,CCI,7037,00091,ZA8,,NB,X, + 114,Verwendungszweck der Werte,SG10,CAV,,00092,,,,Muss, + 115,Verwendungszweck der Werte,SG10,CAV,7111,00092,ZD1,,Blindarbeitabrechnung /Betriebsführung,X, + 116,Produkt-Daten für Lieferant relevant,SG10,,,,,,,Muss, + 117,Produkt-Daten für Lieferant relevant,SG10,CCI,,00093,,,,Muss, + 118,Produkt-Daten für Lieferant relevant,SG10,CCI,7037,00093,ZA7,,LF,X, + 119,Verwendungszweck der Werte,SG10,CAV,,00094,,,,Muss, + 120,Verwendungszweck der Werte,SG10,CAV,7111,00094,Z47,,Endkundenabrechnung,X [1P1..1], + 121,Verwendungszweck der Werte,SG10,CAV,7111,,ZD1,,Blindarbeitabrechnung /Betriebsführung,X [1P1..1], + 122,Produkt-Daten der Netzlokation,SG8,,,,,,,Soll [294] ∧[336],"[294] Wenn SG5 LOC+Z18 (Netzlokation) vorhanden + [336] Wenn in Änderungsmeldung gefüllt + [530] Hinweis: Es sind alle an der Lokation vorhandenen Daten, die mit dieser Segmentgruppe übermittelt werden und zum Datum „Änderung zum“ Gültigkeit haben, anzugeben. Dies kann zur Folge haben, dass Segmentgruppen bzw. Segmente zu wiederholen sind" + 123,Produkt-Daten der Netzlokation,SG8,SEQ,,00095,,,,Muss, + 124,Produkt-Daten der Netzlokation,SG8,SEQ,1229,00095,Z60,,Produkt-Daten derNetzlokation,X, + 125,Referenz auf die ID der Netzlokation,SG8,RFF,,00096,,,,Muss, + 126,Referenz auf die ID der Netzlokation,SG8,RFF,1153,00096,Z32,,Netzlokation,X, + 127,Referenz auf die ID der Netzlokation,SG8,RFF,1154,00096,,,ID einer Netzlokation,X [960],[960] Format: Netzlokations-ID + 128,Produkt-Daten der Netzlokation,SG8,PIA,,00097,,,,Muss [445],[445] Wenn in derselben SG8 SEQ+Z60 (Produkt- Daten der Netzlokation) das SG10 CCI+11 (Details zum Produkt der Netzlokation) nicht vorhanden + 129,Produkt-Daten der Netzlokation,SG8,PIA,4347,00097,5,,Produktidentifikation,X, + 130,Produkt-Daten der Netzlokation,SG8,PIA,7140,00097,,,Konfigurationsprodukt-Code,X [412],"[412] Es sind ausschließlich Konfigurationsprodukt- Codes der ""EDI@Energy Codeliste der Konfigurationen"" aus Kapitel 4.2 Konfigurationsprodukte Leistungskurvendefinitio n erlaubt" + 131,Produkt-Daten der Netzlokation,SG8,PIA,7143,00097,Z12,,Konfigurationsprodukt,X, + 132,Details zum Produkt der Netzlokation,SG10,,,,,,,Muss [444],[444] Wenn in derselben SG8 SEQ+Z60 (Produkt- Daten der Netzlokation) das PIA+5 (Produkt- Daten der Netzlokation) nicht vorhanden + 133,Details zum Produkt der Netzlokation,SG10,CCI,,00098,,,,Muss, + 134,Details zum Produkt der Netzlokation,SG10,CCI,7059,00098,11,,Produkt,X, + 135,Details zum Produkt der Netzlokation,SG10,CCI,7037,00098,ZF6,,Kein Produkt an derNetzlokation zugeordnet,X, + 136,Zugeordnete Leistungskurvendefinition,SG10,,,,,,,Muss [190],[190] Wenn in derselben SG8 SEQ+Z60 (Produkt- Daten der Netzlokation) PIA+5+9991000000721: Z12 vorhanden + 137,Zugeordnete Leistungskurvendefinition,SG10,CCI,,00099,,,,Muss, + 138,Zugeordnete Leistungskurvendefinition,SG10,CCI,7059,00099,Z53,,Code derLeistungskurvendefinition,X, + 139,Zugeordnete Leistungskurvendefinition,SG10,CCI,7037,00099,,,Code der,X, + 140,Auftraggebender Marktpartner,SG10,,,,,,,Muss, + 141,Auftraggebender Marktpartner,SG10,CCI,,00100,,,,Muss, + 142,Auftraggebender Marktpartner,SG10,CCI,7037,00100,ZB3,,ZugeordneterMarktpartner,X, + 143,Auftraggebender Marktpartner,SG10,CAV,,00101,,,,Muss, + 144,Auftraggebender Marktpartner,SG10,CAV,7111,00101,Z88,,NB,X, + 145,Auftraggebender Marktpartner,SG10,CAV,7111,,Z89,,LF,X, + 146,Auftraggebender Marktpartner,SG10,CAV,1131,00101,,,MP-ID,X, + 147,Produkt-Daten für Marktrolle relevant,SG10,,,,,,,Muss, + 148,Produkt-Daten für Marktrolle relevant,SG10,CCI,,00102,,,,Muss, + 149,Produkt-Daten für Marktrolle relevant,SG10,CCI,7037,00102,ZA7,,LF,X [1P0..1], + 150,Produkt-Daten für Marktrolle relevant,SG10,CCI,7037,,ZA8,,NB,X [1P0..1], + 151,Daten der Marktlokation,SG8,,,,,,,Muss [25] ∧[2061],"[25] Wenn SG5 LOC+Z16 (Marktlokation) vorhanden + [2061] Segment bzw. Segmentgruppe ist genau einmal je SG4 IDE (Vorgang) anzugeben" + 152,Daten der Marktlokation,SG8,SEQ,,00103,,,,Muss, + 153,Daten der Marktlokation,SG8,SEQ,1229,00103,Z01,,Daten der Marktlokation,X, + 154,Referenz auf die ID der Marktlokation,SG8,RFF,,00104,,,,Muss, + 155,Referenz auf die ID der Marktlokation,SG8,RFF,1153,00104,Z18,,Marktlokation,X, + 156,Referenz auf die ID der Marktlokation,SG8,RFF,1154,00104,,,ID der Marktlokation,X [950],[950] Format: Marktlokations-ID + 157,Lieferrichtung,SG10,,,,,,,Muss, + 158,Lieferrichtung,SG10,CCI,,00110,,,,Muss, + 159,Lieferrichtung,SG10,CCI,7059,00110,Z30,,Lieferrichtung,X, + 160,Lieferrichtung,SG10,CCI,7037,00110,Z06,,Erzeugung,X, + 161,Lieferrichtung,SG10,CCI,7037,,Z07,,Verbrauch,X, + 162,OBIS-Daten der Marktlokation,SG8,,,,,,,Soll [25] ∧[336],"[25] Wenn SG5 LOC+Z16 (Marktlokation) vorhanden + [336] Wenn in Änderungsmeldung gefüllt + [530] Hinweis: Es sind alle an der Lokation vorhandenen Daten, die mit dieser Segmentgruppe übermittelt werden und zum Datum „Änderung zum“ Gültigkeit haben, anzugeben. Dies kann zur Folge haben, dass Segmentgruppen bzw. Segmente zu wiederholen sind" + 163,OBIS-Daten der Marktlokation,SG8,SEQ,,00198,,,,Muss, + 164,OBIS-Daten der Marktlokation,SG8,SEQ,1229,00198,Z02,,OBIS-Daten derMarktlokation,X, + 165,Referenz auf die ID der Marktlokation,SG8,RFF,,00199,,,,Muss, + 166,Referenz auf die ID der Marktlokation,SG8,RFF,1153,00199,Z18,,Marktlokation,X, + 167,Referenz auf die ID der Marktlokation,SG8,RFF,1154,00199,,,ID einer Marktlokation,X [950],[950] Format: Marktlokations-ID + 168,OBIS-Kennzahl der Marktlokation,SG8,PIA,,00200,,,,Muss, + 169,OBIS-Kennzahl der Marktlokation,SG8,PIA,4347,00200,5,,Produktidentifikation,X, + 170,OBIS-Kennzahl der Marktlokation,SG8,PIA,7140,00200,,,OBIS-Kennzahl der Marktlokation,X [314],"[314] Es sind alle OBIS- Kennzahlen gem. EDI@Energy Codeliste der OBIS-Kennzahlen und Medien für den deutschen Energiemarkt Kap. 3 anzugeben, welche an der Marktlokation erforderlich sind. Der Mindestumfang der OBIS-Kennzahlen ergibt sich aus den genannten" + 171,OBIS-Kennzahl der Marktlokation,SG8,PIA,7143,00200,SRW,,OBIS-Kennzahl,X, + 172,Wertegranularität,SG10,,,,,,,Muss [257]⊻ [288],"[257] Wenn in derselben SG8 SEQ+Z02 (OBIS- Daten der Marktlokation) das PIA+5+1-b?:1.9.e vorhanden + [288] Wenn in derselben SG8 SEQ+Z02 (OBIS- Daten der Marktlokation) das PIA+5+1-b?:2.9.e vorhanden" + 173,Wertegranularität,SG10,CCI,,00201,,,,Muss, + 174,Wertegranularität,SG10,CCI,7037,00201,ZE4,,Wertegranularität,X, + 175,Wertegranularität,SG10,CAV,,00202,,,,Muss, + 176,Wertegranularität,SG10,CAV,7111,00202,ZD9,,Jährlich,X, + 177,Wertegranularität,SG10,CAV,7111,,ZE8,,Halbjährlich,X, + 178,Wertegranularität,SG10,CAV,7111,,ZE9,,Quartalsweise,X, + 179,Wertegranularität,SG10,CAV,7111,,ZB7,,Monatlich,X, + 180,Zugeordnete Zählzeitdefinition,SG10,,,,,,,Muss [327]∧ [386] ∧[387],"[327] Wenn DTM+157 (Änderung zum) im DE2380 ≥ 202212312300?+00 + [386] Wenn mehr als eine SG8 SEQ+Z02 (OBIS-Daten der Marktlokation) mit einer OBIS-Kennzahl für Energiemenge im PIA+5 vorhanden + [387] Wenn in derselben SG8 SEQ+Z02 (OBIS Daten der Marktlokation) eine OBIS-Kennzahl für Energiemenge im PIA+5" + 181,Zugeordnete Zählzeitdefinition,SG10,CCI,,00203,,,,Muss, + 182,Zugeordnete Zählzeitdefinition,SG10,CCI,7059,00203,Z39,,Code derZählzeitdefinition,X, + 183,Zugeordnete Zählzeitdefinition,SG10,CCI,7037,00203,,,Code der Zählzeitdefinition,X, + 184,Zugeordnetes Zählzeitregister ,SG10,,,,,,,Muss [421],[421] Wenn in dieser SG8 das SG10 CCI+Z39 (Zugeordnete Zählzeitdefinition) vorhanden ist + 185,Zugeordnetes Zählzeitregister ,SG10,CCI,,00204,,,,Muss, + 186,Zugeordnetes Zählzeitregister ,SG10,CCI,7059,00204,Z38,,Code desZählzeitregisters,X, + 187,Zugeordnetes Zählzeitregister ,SG10,CCI,7037,00204,,,Code des Zählzeitregisters,X, + 188,OBIS Daten für Netzbetreiber relevant,SG10,,,,,,,Muss, + 189,OBIS Daten für Netzbetreiber relevant,SG10,CCI,,00205,,,,Muss, + 190,OBIS Daten für Netzbetreiber relevant,SG10,CCI,7037,00205,ZA8,,NB,X, + 191,Verwendungszweck der Werte,SG10,CAV,,00206,,,,Muss, + 192,Verwendungszweck der Werte,SG10,CAV,7111,00206,Z84,,Netznutzungsabrechnun,X [29P1..1] ⊻g[32P1..1] ⊻[36P1..1], + 193,Verwendungszweck der Werte,SG10,CAV,7111,,Z85,,Bilanzkreisabrechnung,X [31P0..1] ⊻[32P0..1] ⊻[33P0..1] ⊻[34P0..1], + 194,Verwendungszweck der Werte,SG10,CAV,7111,,Z86,,Mehrmindermengenabre,X [30P1..1] ⊻chnung, + 195,Verwendungszweck der Werte,SG10,CAV,7111,,Z92,,Übermittlung an das,X [33P1..1] ⊻HKNR, + 196,Verwendungszweck der Werte,SG10,CAV,7111,,ZD1,,Blindarbeitabrechnung /Betriebsführung,X [28P1..1], + 197,Verwendungszweck der Werte,SG10,CAV,7111,,ZE1,,Es liegt keinVerwendungszweck vor,X [38P1..1], + 198,OBIS Daten für Lieferant relevant,SG10,,,,,,,Muss, + 199,OBIS Daten für Lieferant relevant,SG10,CCI,,00207,,,,Muss, + 200,OBIS Daten für Lieferant relevant,SG10,CCI,7037,00207,ZA7,,LF,X, + 201,Verwendungszweck der Werte,SG10,CAV,,00208,,,,Muss, + 202,Verwendungszweck der Werte,SG10,CAV,7111,00208,Z84,,Netznutzungsabrechnun,X [29P0..1] ⊻g[32P0..1] ⊻[36P0..1], + 203,Verwendungszweck der Werte,SG10,CAV,7111,,Z85,,Bilanzkreisabrechnung,X [31P1..1] ⊻[32P1..1] ⊻[33P1..1] ⊻[34P1..1], + 204,Verwendungszweck der Werte,SG10,CAV,7111,,Z86,,Mehrmindermengenabre,X [30P1..1] ⊻chnung, + 205,Verwendungszweck der Werte,SG10,CAV,7111,,Z47,,Endkundenabrechnung,X [28P0..1] ⊻[29P1..1] ⊻[30P0..1] ⊻[32P1..1] ⊻[34P1..1] ⊻[35P1..1] ⊻[36P0..1] ⊻[37P1..1], + 206,Verwendungszweck der Werte,SG10,CAV,7111,,ZD1,,Blindarbeitabrechnung /Betriebsführung,X [28P0..1], + 207,Verwendungszweck der Werte,SG10,CAV,7111,,ZE1,,Es liegt keinVerwendungszweck vor,X [38P1..1], + 208,OBIS Daten für Übertragungsnetzbetreiber relevant,SG10,,,,,,,Muss [396],[396] Wenn in derselben SG8 SEQ+Z02 (OBIS- Daten der Marktlokation) eine OBIS-Kennzahl für Wirkarbeit und 1/4 Stunde im PIA+5 vorhanden + 209,OBIS Daten für Übertragungsnetzbetreiber relevant,SG10,CCI,,00209,,,,Muss, + 210,OBIS Daten für Übertragungsnetzbetreiber relevant,SG10,CCI,7037,00209,ZA9,,ÜNB,X, + 211,Verwendungszweck der Werte,SG10,CAV,,00210,,,,Muss, + 212,Verwendungszweck der Werte,SG10,CAV,7111,00210,Z85,,Bilanzkreisabrechnung,X [1P0..1], + 213,Verwendungszweck der Werte,SG10,CAV,7111,,ZB5,,Zur Ermittlung derAusgeglichenheit vonBilanzkreisen,X [1P1..1], + 214,Produkt-Daten der Marktlokation,SG8,,,,,,,Soll [25] ∧[336],"[25] Wenn SG5 LOC+Z16 (Marktlokation) vorhanden + [166] Wenn vorhanden + [336] Wenn in Änderungsmeldung gefüllt + [530] Hinweis: Es sind alle an der Lokation vorhandenen Daten, die mit dieser Segmentgruppe übermittelt werden und zum Datum „Änderung zum“ Gültigkeit haben, anzugeben. Dies kann zur Folge haben, dass Segmentgruppen bzw. Segmente zu wiederholen sind" + 215,Produkt-Daten der Marktlokation,SG8,SEQ,,00211,,,,Muss, + 216,Produkt-Daten der Marktlokation,SG8,SEQ,1229,00211,Z59,,Produkt-Daten derMarktlokation,X, + 217,Referenz auf die ID der Marktlokation,SG8,RFF,,00212,,,,Muss, + 218,Referenz auf die ID der Marktlokation,SG8,RFF,1153,00212,Z18,,Marktlokation,X, + 219,Referenz auf die ID der Marktlokation,SG8,RFF,1154,00212,,,ID einer Marktlokation,X [950],[950] Format: Marktlokations-ID + 220,Produkt-Daten der Marktlokation,SG8,PIA,,00213,,,,Muss, + 221,Produkt-Daten der Marktlokation,SG8,PIA,4347,00213,5,,Produktidentifikation,X, + 222,Produkt-Daten der Marktlokation,SG8,PIA,7140,00213,,,Produkt-/Leistungsnummer,X, + 223,Produkt-Daten der Marktlokation,SG8,PIA,7143,00213,Z12,,Konfigurationsprodukt,X, + 224,Zugeordnete Definition,SG10,,,,,,,Muss, + 225,Zugeordnete Definition,SG10,CCI,,00214,,,,Muss, + 226,Zugeordnete Definition,SG10,CCI,7059,00214,Z53,,Code derLeistungskurvendefinition,X, + 227,Zugeordnete Definition,SG10,CCI,7037,00214,,,Code der Definition,X, + 228,Produkt-Daten für Marktrolle relevant,SG10,,,,,,,Muss, + 229,Produkt-Daten für Marktrolle relevant,SG10,CCI,,00215,,,,Muss, + 230,Produkt-Daten für Marktrolle relevant,SG10,CCI,7037,00215,ZA8,,NB,X [1P0..1], + 231,Produkt-Daten für Marktrolle relevant,SG10,CCI,7037,,ZA7,,LF,X [1P0..1], + 232,OBIS-Daten der Tranche,SG8,,,,,,,Soll [336],"[167] Wenn SG5 LOC+Z21 (Tranche) vorhanden + [336] Wenn in Änderungsmeldung gefüllt + [530] Hinweis: Es sind alle an der Lokation vorhandenen Daten, die mit dieser Segmentgruppe übermittelt werden und zum Datum „Änderung zum“ Gültigkeit haben, anzugeben. Dies kann zur Folge haben, dass Segmentgruppen bzw. Segmente zu wiederholen sind" + 233,OBIS-Daten der Tranche,SG8,SEQ,,00260,,,,Muss, + 234,OBIS-Daten der Tranche,SG8,SEQ,1229,00260,Z17,,OBIS-Daten der Tranche,X, + 235,Referenz auf die ID einer Tranche,SG8,RFF,,00261,,,,Muss, + 236,Referenz auf die ID einer Tranche,SG8,RFF,1153,00261,Z20,,Tranche,X, + 237,Referenz auf die ID einer Tranche,SG8,RFF,1154,00261,,,ID einer Tranche,X [950],[950] Format: Marktlokations-ID + 238,OBIS-Kennzahl der Tranche,SG8,PIA,,00262,,,,Muss, + 239,OBIS-Kennzahl der Tranche,SG8,PIA,4347,00262,5,,Produktidentifikation,X, + 240,OBIS-Kennzahl der Tranche,SG8,PIA,7140,00262,,,OBIS-Kennzahl der Tranche,X [269],[269] Es sind alle OBIS- Kennzahlen gem. EDI@Energy Codeliste der OBIS-Kennzahlen und Medien für den deutschen Energiemarkt + 241,OBIS-Kennzahl der Tranche,SG8,PIA,7143,00262,SRW,,OBIS-Kennzahl,X, + 242,OBIS Daten für Netzbetreiber relevant,SG10,,,,,,,Muss, + 243,OBIS Daten für Netzbetreiber relevant,SG10,CCI,,00263,,,,Muss, + 244,OBIS Daten für Netzbetreiber relevant,SG10,CCI,7037,00263,ZA8,,NB,X, + 245,Verwendungszweck der Werte,SG10,CAV,,00264,,,,Muss, + 246,Verwendungszweck der Werte,SG10,CAV,7111,00264,Z85,,Bilanzkreisabrechnung,X [1P0..1], + 247,Verwendungszweck der Werte,SG10,CAV,7111,,Z92,,Übermittlung an dasHKNR,, + 248,OBIS Daten für Lieferant relevant,SG10,,,,,,,Muss, + 249,OBIS Daten für Lieferant relevant,SG10,CCI,,00265,,,,Muss, + 250,OBIS Daten für Lieferant relevant,SG10,CCI,7037,00265,ZA7,,LF,X, + 251,Verwendungszweck der Werte,SG10,CAV,,00266,,,,Muss, + 252,Verwendungszweck der Werte,SG10,CAV,7111,00266,Z85,,Bilanzkreisabrechnung,X [1P1..1], + 253,Verwendungszweck der Werte,SG10,CAV,7111,,Z47,,Endkundenabrechnung,X [1P1..1], + 254,OBIS Daten für Übertragungsnetzbetreiber relevant,SG10,,,,,,,Muss, + 255,OBIS Daten für Übertragungsnetzbetreiber relevant,SG10,CCI,,00267,,,,Muss, + 256,OBIS Daten für Übertragungsnetzbetreiber relevant,SG10,CCI,7037,00267,ZA9,,ÜNB,X, + 257,Verwendungszweck der Werte,SG10,CAV,,00268,,,,Muss, + 258,Verwendungszweck der Werte,SG10,CAV,7111,00268,Z85,,Bilanzkreisabrechnung,X [1P0..1], + 259,Verwendungszweck der Werte,SG10,CAV,7111,,ZB5,,Zur Ermittlung derAusgeglichenheit vonBilanzkreisen,X [1P1..1], + 260,Daten der Steuerbaren Ressource,SG8,,,,,,,Muss [205],[205] Wenn SG5 LOC+Z19 (Steuerbare Ressource) vorhanden + 261,Daten der Steuerbaren Ressource,SG8,SEQ,,00293,,,,Muss, + 262,Daten der Steuerbaren Ressource,SG8,SEQ,1229,00293,Z62,,Daten der SteuerbarenRessource,X, + 263,Referenz auf die ID der Steuerbaren Ressource,SG8,RFF,,00294,,,,Muss, + 264,Referenz auf die ID der Steuerbaren Ressource,SG8,RFF,1153,00294,Z38,,Steuerbare Ressource,X, + 265,Referenz auf die ID der Steuerbaren Ressource,SG8,RFF,1154,00294,,,ID der Steuerbaren Ressource,X [961],[961] Format: SR-ID + 266,Steuerkanal,SG10,,,,,,,Muss, + 267,Steuerkanal,SG10,CCI,,00295,,,,Muss, + 268,Steuerkanal,SG10,CCI,7059,00295,Z49,,Steuerkanal,X, + 269,Leistungsbeschreibung des Steuerkanals,SG10,CAV,,00296,,,,Muss, + 270,Leistungsbeschreibung des Steuerkanals,SG10,CAV,7111,00296,ZF2,,Leistungsbeschreibungdes Steuerkanals,X, + 271,Leistungsbeschreibung des Steuerkanals,SG10,CAV,1131,00296,Z14,,An/Aus,X, + 272,Leistungsbeschreibung des Steuerkanals,SG10,CAV,1131,,Z15,,Gestuft,X, + 273,Produkt-Daten der Steuerbaren Ressource,SG8,,,,,,,Soll [205] ∧[336],"[205] Wenn SG5 LOC+Z19 (Steuerbare Ressource) vorhanden + [336] Wenn in Änderungsmeldung gefüllt + [530] Hinweis: Es sind alle an der Lokation vorhandenen Daten, die mit dieser Segmentgruppe übermittelt werden und zum Datum „Änderung zum“ Gültigkeit haben, anzugeben. Dies kann zur Folge haben, dass Segmentgruppen bzw. Segmente zu wiederholen sind" + 274,Produkt-Daten der Steuerbaren Ressource,SG8,SEQ,,00299,,,,Muss, + 275,Produkt-Daten der Steuerbaren Ressource,SG8,SEQ,1229,00299,Z61,,Produkt-Daten derSteuerbaren Ressource,X, + 276,Referenz auf die ID der Steuerbaren Ressource,SG8,RFF,,00300,,,,Muss, + 277,Referenz auf die ID der Steuerbaren Ressource,SG8,RFF,1153,00300,Z38,,Steuerbare Ressource,X, + 278,Referenz auf die ID der Steuerbaren Ressource,SG8,RFF,1154,00300,,,ID einer Steuerbaren Ressource,X [961],[961] Format: SR-ID + 279,Produkt-Daten der Steuerbaren Ressource,SG8,PIA,,00301,,,,Muss, + 280,Produkt-Daten der Steuerbaren Ressource,SG8,PIA,4347,00301,5,,Produktidentifikation,X, + 281,Produkt-Daten der Steuerbaren Ressource,SG8,PIA,7140,00301,,,Konfigurationsprodukt-Code,X, + 282,Produkt-Daten der Steuerbaren Ressource,SG8,PIA,7143,00301,Z12,,Konfigurationsprodukt,X, + 283,Zugeordnete Definition,SG10,,,,,,,Muss, + 284,Zugeordnete Definition,SG10,CCI,,00302,,,,Muss, + 285,Zugeordnete Definition,SG10,CCI,7059,00302,Z52,,Code derSchaltzeitdefinition,X, + 286,Zugeordnete Definition,SG10,CCI,7059,,Z53,,Code derLeistungskurvendefinition,X, + 287,Zugeordnete Definition,SG10,CCI,7037,00302,,,Code der Definition,X, + 288,Auftraggebender Marktpartner,SG10,,,,,,,Muss, + 289,Auftraggebender Marktpartner,SG10,CCI,,00303,,,,Muss, + 290,Auftraggebender Marktpartner,SG10,CCI,7037,00303,ZB3,,ZugeordneterMarktpartner,X, + 291,Auftraggebender Marktpartner,SG10,CAV,,00304,,,,Muss, + 292,Auftraggebender Marktpartner,SG10,CAV,7111,00304,Z88,,NB,X, + 293,Auftraggebender Marktpartner,SG10,CAV,7111,,Z89,,LF,X, + 294,Auftraggebender Marktpartner,SG10,CAV,1131,00304,,,MP-ID,X, + 295,Produkt-Daten für Marktrolle relevant,SG10,,,,,,,Muss, + 296,Produkt-Daten für Marktrolle relevant,SG10,CCI,,00305,,,,Muss, + 297,Produkt-Daten für Marktrolle relevant,SG10,CCI,7037,00305,ZA8,,NB,X [1P0..1], + 298,Produkt-Daten für Marktrolle relevant,SG10,CCI,7037,,ZA7,,LF,X [1P0..1], + 299,Daten der Messlokation,SG8,,,,,,,Muss [345] ,[345] Wenn SG5 LOC+Z17 (Messlokation) vorhanden + 300,Daten der Messlokation,SG8,SEQ,,00306,,,,Muss, + 301,Daten der Messlokation,SG8,SEQ,1229,00306,Z18,,Daten der Messlokation,X, + 302,Referenz auf die ID der Messlokation,SG8,RFF,,00307,,,,Muss, + 303,Referenz auf die ID der Messlokation,SG8,RFF,1153,00307,Z19,,Messlokation,X, + 304,Referenz auf die ID der Messlokation,SG8,RFF,1154,00307,,,ID der Messlokation,X [951],[951] Format: Zählpunktbezeichnung + 305,Spannungsebene der Messlokation,SG10,,,,,,,Muss, + 306,Spannungsebene der Messlokation,SG10,CCI,,00314,,,,Muss, + 307,Spannungsebene der Messlokation,SG10,CCI,7037,00314,E04,,Spannungsebene derMesslokation,X, + 308,Spannungsebene der Messlokation,SG10,CAV,,00315,,,,Muss, + 309,Spannungsebene der Messlokation,SG10,CAV,7111,00315,E03,,Höchstspannung,X, + 310,Spannungsebene der Messlokation,SG10,CAV,7111,,E04,,Hochspannung,X, + 311,Spannungsebene der Messlokation,SG10,CAV,7111,,E05,,Mittelspannung,X, + 312,Spannungsebene der Messlokation,SG10,CAV,7111,,E06,,Niederspannung,X, + 313,Zähleinrichtungsdaten,SG8,,,,,,,Soll [336],"[336] Wenn in Änderungsmeldung gefüllt + [345] Wenn SG5 LOC+Z17 (Messlokation) vorhanden + [530] Hinweis: Es sind alle an der Lokation vorhandenen Daten, die mit dieser Segmentgruppe übermittelt werden und zum Datum „Änderung zum“ Gültigkeit haben, anzugeben. Dies kann zur Folge haben, dass Segmentgruppen bzw. Segmente zu wiederholen sind" + 314,Zähleinrichtungsdaten,SG8,SEQ,,00326,,,,Muss, + 315,Zähleinrichtungsdaten,SG8,SEQ,1229,00326,Z03,,Zähleinrichtungsdaten,X, + 316,Referenz auf die ID einer Messlokation,SG8,RFF,,00327,,,,Muss, + 317,Referenz auf die ID einer Messlokation,SG8,RFF,1153,00327,Z19,,Messlokation,X, + 318,Referenz auf die ID einer Messlokation,SG8,RFF,1154,00327,,,ID einer Messlokation,X [951],[951] Format: Zählpunktbezeichnung + 319,Referenz auf das Smartmeter-Gateway,SG8,RFF,,00328,,,,Soll [166] ∧[215],"[166] Wenn vorhanden + [215] Wenn in derselben SG8 SEQ+Z03 (Zähleinrichtungsdaten) SG10 CCI+++E13 CAV+MME (Zählertyp: mME) vorhanden" + 320,Referenz auf das Smartmeter-Gateway,SG8,RFF,1153,00328,Z14,,Smartmeter-Gateway,X, + 321,Referenz auf das Smartmeter-Gateway,SG8,RFF,1154,00328,,,Identifikation / Nummer desSmartmeter-Gateways,X, + 322,Zählertyp,SG10,,,,,,,Muss, + 323,Zählertyp,SG10,CCI,,00329,,,,Muss, + 324,Zählertyp,SG10,CCI,7037,00329,E13,,Zählertyp,X, + 325,Zählertyp,SG10,CAV,,00330,,,,Muss, + 326,Zählertyp,SG10,CAV,7111,00330,AHZ,,analoger Haushaltszähler(Drehstrom),X, + 327,Zählertyp,SG10,CAV,7111,,WSZ,,analogerWechselstromzähler,X, + 328,Zählertyp,SG10,CAV,7111,,LAZ,,Lastgangzähler,X, + 329,Zählertyp,SG10,CAV,7111,,MAZ,,Maximumzähler,X, + 330,Zählertyp,SG10,CAV,7111,,MME,,moderneMesseinrichtung nachMsbG,X, + 331,Zählertyp,SG10,CAV,7111,,EHZ,,elektronischerHaushaltszähler,X, + 332,Zählertyp,SG10,CAV,7111,,IVA,,Individuelle Abstimmung(Sonderausstattung),X, + 333,Zählertyp,SG10,CAV,7110,00330,Z01,,EDL40,X [136], + 334,Zählertyp,SG10,CAV,7110,,Z02,,EDL21,X [136], + 335,Zählertyp,SG10,CAV,7110,,Z03,,sonstiger EHZ,X [136], + 336,Zählertyp,SG10,CAV,7110,,Z04,,Standard,X [346], + 337,Zählertyp,SG10,CAV,7110,,Z05,,MeDa-Zähler,X [346],"[136] Wenn SG10 CCI+++E13 (Zählertyp) CAV+EHZ (elektronischer Haushaltszähler) vorhanden + [346] Wenn SG10" + 338,Identifikation / Nummer des Gerätes,SG10,CAV,,00331,,,,Muss, + 339,Identifikation / Nummer des Gerätes,SG10,CAV,7111,00331,Z30,,Gerätenummer,X, + 340,Identifikation / Nummer des Gerätes,SG10,CAV,7110,00331,,,Gerätenummer,X, + 341,Registeranzahl,SG10,CAV,,00332,,,,Muss [139],[139] Wenn SG10 CAV+IVA (Individuelle Abstimmung) nicht vorhanden + 342,Registeranzahl,SG10,CAV,7111,00332,ETZ,,Eintarif,X, + 343,Registeranzahl,SG10,CAV,7111,,ZTZ,,Zweitarif,X, + 344,Registeranzahl,SG10,CAV,7111,,NTZ,,Mehrtarif,X, + 345,Energierichtung,SG10,CAV,,00333,,,,Muss, + 346,Energierichtung,SG10,CAV,7111,00333,ERZ,,Einrichtungszähler,X, + 347,Energierichtung,SG10,CAV,7111,,ZRZ,,Zweirichtungszähler,X, + 348,Fernschaltung der Zähleinrichtung,SG10,CAV,,00334,,,,Muss, + 349,Fernschaltung der Zähleinrichtung,SG10,CAV,7111,00334,Z58,,Fernschaltung derZähleinrichtung,X, + 350,Fernschaltung der Zähleinrichtung,SG10,CAV,7110,00334,Z06,,vorhanden,X, + 351,Fernschaltung der Zähleinrichtung,SG10,CAV,7110,,Z07,,nicht vorhanden,X, + 352,Befestigungsart Zähleinrichtung,SG10,,,,,,,, + 353,Befestigungsart Zähleinrichtung,SG10,CCI,,00335,,,,, + 354,Befestigungsart Zähleinrichtung,SG10,CCI,7037,00335,Z28,,BefestigungsartZähleinrichtung,, + 355,Befestigungsart Zähleinrichtung,SG10,CAV,,00336,,,,, + 356,Befestigungsart Zähleinrichtung,SG10,CAV,7111,00336,BKE,,Stecktechnik(Befestigungs- undKontaktierungseinrichtung),, + 357,Befestigungsart Zähleinrichtung,SG10,CAV,7111,,DPA,,3-Dreipunktaufhängung,, + 358,Messwerterfassung an der Zähleinrichtung,SG10,,,,,,,Muss [316],[316] Wenn in derselben SG8 das RFF+Z14 (Smartmeter-Gateway) nicht vorhanden + 359,Messwerterfassung an der Zähleinrichtung,SG10,CCI,,00337,,,,Muss, + 360,Messwerterfassung an der Zähleinrichtung,SG10,CCI,7037,00337,E12,,Messwerterfassung ander Zähleinrichtung,X, + 361,Messwerterfassung an der Zähleinrichtung,SG10,CAV,,00338,,,,Muss, + 362,Messwerterfassung an der Zähleinrichtung,SG10,CAV,7111,00338,AMR,,fernauslesbare Zähler,X, + 363,Messwerterfassung an der Zähleinrichtung,SG10,CAV,7111,,MMR,,manuell ausgeleseneZähler,X, + 364,OBIS-Daten der Zähleinrichtung / Smartmeter-Gateway,SG8,,,,,,,Soll [336],"[121] Wenn in dem SEQ+Z03 (Zähleinrichtungsdaten) das SG8 RFF+Z14 (Referenz auf das Smartmeter-Gateway) nicht vorhanden + [336] Wenn in Änderungsmeldung gefüllt + [345] Wenn SG5 LOC+Z17 (Messlokation) vorhanden + [530] Hinweis: Es sind alle an der Lokation vorhandenen Daten, die mit dieser Segmentgruppe übermittelt werden und zum Datum „Änderung zum“ Gültigkeit haben, anzugeben. Dies kann zur Folge haben, dass Segmentgruppen bzw. Segmente zu wiederholen sind " + 365,OBIS-Daten der Zähleinrichtung / Smartmeter-Gateway,SG8,SEQ,,00339,,,,Muss, + 366,OBIS-Daten der Zähleinrichtung / Smartmeter-Gateway,SG8,SEQ,1229,00339,Z20,,OBIS-Daten derZähleinrichtung,X, + 367,Referenz auf die Gerätenummer,SG8,RFF,,00340,,,,Muss [665],[665] Hinweis: Wenn ein Zähler mit einem SMGW parametriert ist werden an dem Zähler keine OBIS-Kennzahlen angegeben Hier gibt es nur OBIS Kennzahlen vom SMGW + 368,Referenz auf die Gerätenummer,SG8,RFF,1153,00340,MG,,Gerätenummer desZählers,X [441], + 369,Referenz auf die Gerätenummer,SG8,RFF,1153,,Z14,,Smartmeter-Gateway,X,[441] Wenn im SG8+SEQ+Z03 (Zähleinrichtungsdaten) für die in diesem RFF DE1154 genannte Gerätenummer eines Zählers das RFF+Z14 (Referenz auf das Smartmeter-Gateway) nicht vorhanden ist + 370,Referenz auf die Gerätenummer,SG8,RFF,1154,00340,,,Gerätenummer,X, + 371,Referenz auf die ID einer Messlokation,SG8,RFF,,00341,,,,Muss, + 372,Referenz auf die ID einer Messlokation,SG8,RFF,1153,00341,Z19,,Messlokation,X, + 373,Referenz auf die ID einer Messlokation,SG8,RFF,1154,00341,,,ID einer Messlokation,X [951],[951] Format: + 374,Referenz auf die ID einer Marktlokation,SG8,RFF,,00342,,,,Muss [402]∧ [420] ∧[651],"[402] Wenn in derselben SG8 SEQ+Z20 (OBIS- Daten der Zähleinrichtung / Smartmeter-Gateway) eine OBIS-Kennzahl der Werteart ""Zählerstand"" im PIA+5 vorhanden + [420] Wenn in dieser SG8 das RFF+Z14 (Smartmeter-Gateway) vorhanden ist + [651] Hinweis: Es sind die Marktlokationen anzugeben, zu welchen die hier genannte OBIS benötigt wird " + 375,Referenz auf die ID einer Marktlokation,SG8,RFF,1153,00342,Z18,,Marktlokation,X, + 376,Referenz auf die ID einer Marktlokation,SG8,RFF,1154,00342,,,ID einer Marktlokation,X [950],[950] Format: Marktlokations-ID + 377,Konfigurations-ID,SG8,RFF,,00343,,,,Muss [402]∧ [420],"[402] Wenn in derselben SG8 SEQ+Z20 (OBIS- Daten der Zähleinrichtung / Smartmeter-Gateway) eine OBIS-Kennzahl der Werteart ""Zählerstand"" im PIA+5 vorhanden + [420] Wenn in dieser SG8 das RFF+Z14 (Smartmeter-Gateway) vorhanden ist" + 378,Konfigurations-ID,SG8,RFF,1153,00343,AGK,,Anwendungsreferenznummer,X, + 379,Konfigurations-ID,SG8,RFF,1154,00343,,,"Referenz, Identifikation",X, + 380,OBIS-Kennzahl der Zähleinrichtung / Smartmeter-Gateway,SG8,PIA,,00344,,,,Muss, + 381,OBIS-Kennzahl der Zähleinrichtung / Smartmeter-Gateway,SG8,PIA,4347,00344,5,,Produktidentifikation,X, + 382,OBIS-Kennzahl der Zähleinrichtung / Smartmeter-Gateway,SG8,PIA,7140,00344,,,OBIS-Kennzahl derZähleinrichtung,X [323],"[323] Es sind alle OBIS- Kennzahlen gem. EDI@Energy Codeliste der OBIS-Kennzahlen und Medien für den deutschen Energiemarkt Kap. 3. anzugeben, welche an der Zähleinrichtung genutzt werden. Der Mindestumfang der OBIS-Kennzahlen ergibt sich aus den genannten Messprodukt-Codes dem Kap. 5.1 des Dokumentes ""Codeliste der Konfigurationen""" + 383,OBIS-Kennzahl der Zähleinrichtung / Smartmeter-Gateway,SG8,PIA,7143,00344,SRW,,OBIS-Kennzahl,X, + 384,Wertegranularität,SG10,,,,,,,Muss [256],[256] Wenn in derselben SG8 SEQ+Z20 (OBIS- Daten der Zähleinrichtung / Smartmeter-Gateway) das PIA+5+1-b?:1.8.e / 1-b?:2.8.e vorhanden + 385,Wertegranularität,SG10,CCI,,00345,,,,Muss, + 386,Wertegranularität,SG10,CCI,7037,00345,ZE4,,Wertegranularität,X, + 387,Wertegranularität,SG10,CAV,,00346,,,,Muss, + 388,Wertegranularität,SG10,CAV,7111,00346,ZD9,,Jährlich,X, + 389,Wertegranularität,SG10,CAV,7111,,ZE8,,Halbjährlich,X, + 390,Wertegranularität,SG10,CAV,7111,,ZE9,,Quartalsweise,X, + 391,Wertegranularität,SG10,CAV,7111,,ZB7,,Monatlich,X, + 392,Zugeordnete Zählzeitdefinition,SG10,,,,,,,Muss [390]∧ [391] ∧[327],"[327] Wenn DTM+157 (Änderung zum) im DE2380 ≥ 202212312300?+00 + [390] Wenn mindestens eine weitere SG8 SEQ+Z20 (OBIS-Daten der Zähleinrichtung / Smartmeter-Gateway), die mit dem RFF+Z18" + 393,Zugeordnete Zählzeitdefinition,SG10,CCI,,00347,,,,Muss, + 394,Zugeordnete Zählzeitdefinition,SG10,CCI,7059,00347,Z39,,Code derZählzeitdefinition,X, + 395,Zugeordnete Zählzeitdefinition,SG10,CCI,7037,00347,,,Code der Zählzeitdefinition,X, + 396,Zugeordnetes Zählzeitregister ,SG10,,,,,,,Muss [421],[421] Wenn in dieser SG8 das SG10 CCI+Z39 (Zugeordnete Zählzeitdefinition) vorhanden ist + 397,Zugeordnetes Zählzeitregister ,SG10,CCI,,00348,,,,Muss, + 398,Zugeordnetes Zählzeitregister ,SG10,CCI,7059,00348,Z38,,Code desZählzeitregisters,X, + 399,Zugeordnetes Zählzeitregister ,SG10,CCI,7037,00348,,,Code des Zählzeitregisters,X, + 400,Vor- und Nachkommastellen des Zählwerks,SG10,,,,,,,Soll [336],"[273] Wenn in derselben SG8 SEQ+Z20 (OBIS- Daten der Zähleinrichtung / Smartmeter-Gateway) das PIA+5+1-b?:1.8.e / 1-b?:2.8.e / 1-b?:3.8.e / 1-b?:4.8.e / 1-b?:5.8.e / 1-b?:6.8.e / 1-b?:7.8.e / 1-b?:8.8.e /  1-b?:1.8.63 vorhanden + [336] Wenn in Änderungsmeldung gefüllt" + 401,Vor- und Nachkommastellen des Zählwerks,SG10,CCI,,00349,,,,Muss, + 402,Vor- und Nachkommastellen des Zählwerks,SG10,CCI,7059,00349,11,,Produkt,X, + 403,Vor- und Nachkommastellen des Zählwerks,SG10,CCI,7037,00349,Z33,,Vor- undNachkommastellen desZählwerkes,X, + 404,Vor- und Nachkommastellen des Zählwerks,SG10,CAV,,00350,,,,Muss, + 405,Vor- und Nachkommastellen des Zählwerks,SG10,CAV,7110,00350,,,Angabe der Vorkommastelle,X, + 406,Vor- und Nachkommastellen des Zählwerks,SG10,CAV,7110,00350,,,Angabe der Nachkommastelle,X, + 407,Bezeichnung des Zählwerks auf dem Gerät,SG10,,,,,,,Soll [336],"[123] Wenn noch mindestens eine weitere SG8 SEQ+Z20 (OBIS- Daten der Zähleinrichtung Smartmeter-Gateway) mit dem SG8 RFF+MG (Gerätenummer des Zählers) auf die gleiche Identifikation/Nummer des Gerätes referenziert + [273] Wenn in derselben SG8 SEQ+Z20 (OBIS- Daten der Zähleinrichtung / Smartmeter-Gateway) das PIA+5+1-b?:1.8.e /" + 408,Bezeichnung des Zählwerks auf dem Gerät,SG10,CCI,,00351,,,,Muss, + 409,Bezeichnung des Zählwerks auf dem Gerät,SG10,CCI,7037,00351,Z63,,Lokale Kennzeichnung zuKontrollzwecken,X, + 410,Bezeichnung des Zählwerks auf dem Gerät,SG10,CCI,7036,00351,,,Bezeichnung des Zählwerks aufdem Gerät,X, + 411,Schwachlastfähigkeit,SG10,,,,,,,Muss [256]∧ [312],"[256] Wenn in derselben SG8 SEQ+Z20 (OBIS- Daten der Zähleinrichtung / Smartmeter-Gateway) das PIA+5+1-b?:1.8.e / 1-b?:2.8.e vorhanden + [312] Wenn DTM+157 (Änderung zum) im DE2380 < 202212312300?+00" + 412,Schwachlastfähigkeit,SG10,CCI,,00352,,,,Muss, + 413,Schwachlastfähigkeit,SG10,CCI,7059,00352,Z10,,Schwachlastfähigkeit,X, + 414,Schwachlastfähigkeit,SG10,CCI,7037,00352,Z59,,Nicht-Schwachlast fähig,X, + 415,Schwachlastfähigkeit,SG10,CCI,7037,,Z60,,Schwachlast fähig,X, + 416,Wandlerdaten,SG8,,,,,,,Soll [336] ∧[345],"[133] Wenn an der übermittelten Marktlokation / Messlokation vorhanden + [336] Wenn in Änderungsmeldung gefüllt + [345] Wenn SG5 LOC+Z17 (Messlokation) vorhanden + [530] Hinweis: Es sind alle an der Lokation vorhandenen Daten, die mit dieser Segmentgruppe" + 417,Wandlerdaten,SG8,SEQ,,00353,,,,Muss, + 418,Wandlerdaten,SG8,SEQ,1229,00353,Z04,,Wandler-Daten,X, + 419,Referenz auf die Gerätenummer,SG8,RFF,,00354,,,,Muss, + 420,Referenz auf die Gerätenummer,SG8,RFF,1153,00354,MG,,Gerätenummer desZählers,X, + 421,Referenz auf die Gerätenummer,SG8,RFF,1154,00354,,,Gerätenummer,X, + 422,Wandler,SG10,,,,,,,Muss, + 423,Wandler,SG10,CCI,,00355,,,,Muss, + 424,Wandler,SG10,CCI,7037,00355,Z25,,Wandler,X, + 425,Identifikation / Nummer des Gerätes,SG10,CAV,,00356,,,,Muss [2317]⊻ [2318],"[2317] Wenn in derselben SG8 SEQ+Z04 (Wandlerdaten) das SG10 CCI+++Z25 (Wandler) CAV+MIW/ MPW/MUW vorhanden, ist das Segment mindestens zweimal anzugeben + [2318] Wenn in derselben SG8 SEQ+Z04 (Wandlerdaten) das SG10 CCI+++Z25 (Wandler) CAV+MBW (Blockstromwandler) vorhanden, ist das Segment genau einmal anzugeben" + 426,Identifikation / Nummer des Gerätes,SG10,CAV,7111,00356,Z30,,Gerätenummer,X, + 427,Identifikation / Nummer des Gerätes,SG10,CAV,7110,00356,,,Gerätenummer,X, + 428,Wandlertyp und Faktor,SG10,CAV,,00357,,,,Muss, + 429,Wandlertyp und Faktor,SG10,CAV,7111,00357,MIW,,Messwandlersatz Strom,X, + 430,Wandlertyp und Faktor,SG10,CAV,7111,,MPW,,Kombimesswandlersatz(Strom und Spannung),X, + 431,Wandlertyp und Faktor,SG10,CAV,7111,,MBW,,Blockstromwandler,X, + 432,Wandlertyp und Faktor,SG10,CAV,7111,,MUW,,MesswandlersatzSpannung,X, + 433,Wandlertyp und Faktor,SG10,CAV,7110,00357,,,Wandlerfaktor,X [902][141],"[141] Wenn SG10 CAV+MIW/ MPW/ MBW vorhanden + [902] Format: Möglicher Wert: ≥ 0" + 434,Kommunikationseinrichtun gsdaten,SG8,,,,,,,Soll [336] ∧[345],"[133] Wenn an der übermittelten Marktlokation / Messlokation vorhanden + [336] Wenn in Änderungsmeldung gefüllt + [345] Wenn SG5 LOC+Z17 (Messlokation) vorhanden + [530] Hinweis: Es sind alle an der Lokation vorhandenen Daten, die mit dieser Segmentgruppe übermittelt werden und zum Datum „Änderung zum“ Gültigkeit haben, anzugeben. Dies kann zur Folge haben, dass Segmentgruppen bzw. Segmente zu wiederholen sind + [2119] Je SG8 SEQ+Z13 (Smartmeter-Gateway) ist genau einmal die Segmentgruppe anzugeben" + 435,Kommunikationseinrichtun gsdaten,SG8,SEQ,,00358,,,,Muss, + 436,Kommunikationseinrichtun gsdaten,SG8,SEQ,1229,00358,Z05,,Kommunikationseinrichtungsdaten,X, + 437,Referenz auf die Gerätenummer,SG8,RFF,,00359,,,,Muss, + 438,Referenz auf die Gerätenummer,SG8,RFF,1153,00359,MG,,Gerätenummer desZählers,X, + 439,Referenz auf die Gerätenummer,SG8,RFF,1154,00359,,,Gerätenummer,X, + 440,Kommunikationseinrichtun g,SG10,,,,,,,Muss, + 441,Kommunikationseinrichtun g,SG10,CCI,,00360,,,,Muss, + 442,Kommunikationseinrichtun g,SG10,CCI,7037,00360,Z26,,Kommunikationseinrichtung,X, + 443,Identifikation / Nummer des Gerätes,SG10,CAV,,00361,,,,Muss, + 444,Identifikation / Nummer des Gerätes,SG10,CAV,7111,00361,Z30,,Gerätenummer,X, + 445,Identifikation / Nummer des Gerätes,SG10,CAV,7110,00361,,,Gerätenummer,X, + 446,Kommunikationseinrichtun gstyp,SG10,CAV,,00362,,,,Muss, + 447,Kommunikationseinrichtun gstyp,SG10,CAV,7111,00362,GSM,,GSM/GPRS/UMTS-Kom.-Einr.,X, + 448,Kommunikationseinrichtun gstyp,SG10,CAV,7111,,ETH,,Ethernet-Kom.-Einricht.LAN/WLAN,X, + 449,Kommunikationseinrichtun gstyp,SG10,CAV,7111,,PLC,,PLC-Kom.-Einrichtung,X, + 450,Kommunikationseinrichtun gstyp,SG10,CAV,7111,,PST,,Festnetz-Kom.-Einricht.TAE,X, + 451,Kommunikationseinrichtun gstyp,SG10,CAV,7111,,DSL,,DSL-Kom.Einr.,X, + 452,Kommunikationseinrichtun gstyp,SG10,CAV,7111,,LTE,,LTE-Kom.-Einr.,X, + 453,Daten der technischen Steuereinrichtung,SG8,,,,,,,Soll [336] ∧[345],"[133] Wenn an der übermittelten Marktlokation / Messlokation vorhanden + [336] Wenn in Änderungsmeldung gefüllt + [345] Wenn SG5 LOC+Z17 (Messlokation) vorhanden + [530] Hinweis: Es sind alle an der Lokation" + 454,Daten der technischen Steuereinrichtung,SG8,SEQ,,00363,,,,Muss, + 455,Daten der technischen Steuereinrichtung,SG8,SEQ,1229,00363,Z06,,Daten der technischenSteuereinrichtung,X, + 456,Referenz auf die Gerätenummer,SG8,RFF,,00364,,,,Muss, + 457,Referenz auf die Gerätenummer,SG8,RFF,1153,00364,MG,,Gerätenummer desZählers,X, + 458,Referenz auf die Gerätenummer,SG8,RFF,1154,00364,,,Gerätenummer,X, + 459,Technische Steuereinrichtung,SG10,,,,,,,Muss, + 460,Technische Steuereinrichtung,SG10,CCI,,00365,,,,Muss, + 461,Technische Steuereinrichtung,SG10,CCI,7037,00365,Z27,,TechnischeSteuereinrichtung,X, + 462,Identifikation / Nummer des Gerätes,SG10,CAV,,00366,,,,Muss, + 463,Identifikation / Nummer des Gerätes,SG10,CAV,7111,00366,Z30,,Gerätenummer,X, + 464,Identifikation / Nummer des Gerätes,SG10,CAV,7110,00366,,,Gerätenummer,X, + 465,Technische Steuereinrichtungstyp,SG10,CAV,,00367,,,,Muss, + 466,Technische Steuereinrichtungstyp,SG10,CAV,7111,00367,RSU,,Rundsteuerempfänger,X, + 467,Technische Steuereinrichtungstyp,SG10,CAV,7111,,TSU,,Tarifschaltuhr,X, + 468,Smartmeter-Gateway,SG8,,,,,,,Soll [336] ∧[345],"[130] Wenn an Messlokation vorhanden + [336] Wenn in Änderungsmeldung gefüllt " + 469,Smartmeter-Gateway,SG8,SEQ,,00368,,,,Muss, + 470,Smartmeter-Gateway,SG8,SEQ,1229,00368,Z13,,Smartmeter-Gateway,X, + 471,Smartmeter-Gateway,SG10,,,,,,,Muss, + 472,Smartmeter-Gateway,SG10,CCI,,00369,,,,Muss, + 473,Smartmeter-Gateway,SG10,CCI,7037,00369,Z75,,Smartmeter-Gateway,X, + 474,Identifikation / Nummer des Gerätes,SG10,CAV,,00370,,,,Muss, + 475,Identifikation / Nummer des Gerätes,SG10,CAV,7111,00370,Z30,,Gerätenummer,X, + 476,Identifikation / Nummer des Gerätes,SG10,CAV,7110,00370,,,Gerätenummer,X [952],[952] Format: Gerätenummer nach DIN 43863-5 + 477,Daten der Steuerbox,SG8,,,,,,,Soll [336] ∧[345],"[133] Wenn an der übermittelten Marktlokation / Messlokation vorhanden + [336] Wenn in Änderungsmeldung gefüllt + [345] Wenn SG5 LOC+Z17 (Messlokation) vorhanden" + 478,Daten der Steuerbox,SG8,SEQ,,00371,,,,Muss, + 479,Daten der Steuerbox,SG8,SEQ,1229,00371,Z14,,Steuerbox,X, + 480,Referenz auf das Smartmeter-Gateway,SG8,RFF,,00372,,,,Muss, + 481,Referenz auf das Smartmeter-Gateway,SG8,RFF,1153,00372,Z14,,Smartmeter-Gateway,X, + 482,Referenz auf das Smartmeter-Gateway,SG8,RFF,1154,00372,,,Identifikation / Nummer desSmartmeter-Gateways,X, + 483,Referenz auf die ID der Marktlokation,SG8,RFF,,00373,,,,Muss, + 484,Referenz auf die ID der Marktlokation,SG8,RFF,1153,00373,Z18,,Marktlokation,X, + 485,Referenz auf die ID der Marktlokation,SG8,RFF,1154,00373,,,ID einer Marktlokation,X [950],[950] Format: Marktlokations-ID + 486,Steuerbox,SG10,,,,,,,Muss, + 487,Steuerbox,SG10,CCI,,00374,,,,Muss, + 488,Steuerbox,SG10,CCI,7037,00374,Z76,,Steuerbox,X, + 489,Identifikation / Nummer des Gerätes,SG10,CAV,,00375,,,,Muss, + 490,Identifikation / Nummer des Gerätes,SG10,CAV,7111,00375,Z30,,Gerätenummer,X, + 491,Identifikation / Nummer des Gerätes,SG10,CAV,7110,00375,,,Gerätenummer,X [952],[952] Format: Gerätenummer nach DIN 43863-5 + 492,Nachrichten-Endesegment,,UNT,,00540,,,,Muss, + 493,Nachrichten-Endesegment,,UNT,0074,00540,,,Anzahl der Segmente in einerNachricht,X, + 494,Nachrichten-Endesegment,,UNT,0062,00540,,,Nachrichten-Referenznummer,X, + + ''' +# --- +# name: TestCli.test_kohlrahbi_cli_with_valid_arguments[55157] + ''' + ,Segmentname,Segmentgruppe,Segment,Datenelement,Segment ID,Code,Qualifier,Beschreibung,Bedingungsausdruck,Bedingung + 0,Nachrichten-Kopfsegment,,UNH,,00003,,,,Muss, + 1,Nachrichten-Kopfsegment,,UNH,0062,00003,,,Nachrichten-Referenznummer,X, + 2,Nachrichten-Kopfsegment,,UNH,0065,00003,UTILMD,,Netzanschluss-Stammdaten,X, + 3,Nachrichten-Kopfsegment,,UNH,0052,00003,D,,Entwurfs-Version,X, + 4,Nachrichten-Kopfsegment,,UNH,0054,00003,11A,,Ausgabe 2011 - A,X, + 5,Nachrichten-Kopfsegment,,UNH,0051,00003,UN,,UN/CEFACT,X, + 6,Nachrichten-Kopfsegment,,UNH,0057,00003,Versionsnummer derzugrundeliegendenBDEW-Nachrichtenbeschreibung,,S1.1a,X, + 7,Beginn der Nachricht,,BGM,,00004,,,,Muss, + 8,Beginn der Nachricht,,BGM,1001,00004,E03,,Änderungsmeldungen,X, + 9,Beginn der Nachricht,,BGM,1004,00004,,,Dokumentennummer,X, + 10,Nachrichtendatum,,DTM,,00005,,,,Muss, + 11,Nachrichtendatum,,DTM,2005,00005,137,,Dokumenten-/Nachrichtendatum/-zeit,X, + 12,Nachrichtendatum,,DTM,2380,00005,,,"Datum oder Uhrzeit oderZeitspanne, Wert",X [931] [494],"[494] Das hier genannte Datum muss der Zeitpunkt sein, zu dem das Dokument erstellt wurde, oder ein Zeitpunkt, der davor liegt + [931] Format: ZZZ = +00" + 13,Nachrichtendatum,,DTM,2379,00005,303,,CCYYMMDDHHMMZZZ,X, + 14,MP-ID Absender,SG2,,,,,,,Muss, + 15,MP-ID Absender,SG2,NAD,,00008,,,,Muss, + 16,MP-ID Absender,SG2,NAD,3035,00008,MS,,Dokumenten-/Nachrichtenausstellerbzw. -absender,X, + 17,MP-ID Absender,SG2,NAD,3039,00008,,,MP-ID,X, + 18,MP-ID Absender,SG2,NAD,3055,00008,9,,GS1,X, + 19,MP-ID Absender,SG2,NAD,3055,,293,,"DE, BDEW(Bundesverband derEnergie- undWasserwirtschaft e.V.)",X, + 20,Ansprechpartner,SG3,,,,,,,Kann, + 21,Ansprechpartner,SG3,CTA,,00009,,,,Muss, + 22,Ansprechpartner,SG3,CTA,3139,00009,IC,,Informationskontakt,X, + 23,Ansprechpartner,SG3,CTA,3412,00009,,,Name vom Ansprechpartner,X, + 24,Kommunikationsverbindung,SG3,COM,,00010,,,,Muss, + 25,Kommunikationsverbindung,SG3,COM,3148,00010,,,Nummer / Adresse,X (([939] [321])∨ ([940] [322]))∧ [514],"[321] Wenn im DE3155 in demselben COM der Code EM vorhanden ist + [322] Wenn im DE3155 in demselben COM der Code TE / FX / AJ / AL vorhanden ist + [514] Hinweis: Es darf nur eine Information im DE3148 übermittelt werden + [939] Format: Die Zeichenkette muss die Zeichen @ und . enthalten + [940] Format: Die Zeichenkette muss mit dem Zeichen + beginnen und danach dürfen nur noch Ziffern folgen" + 26,Kommunikationsverbindung,SG3,COM,3155,00010,EM,,Elektronische Post,X [1P0..1], + 27,Kommunikationsverbindung,SG3,COM,3155,,FX,,Telefax,X [1P0..1], + 28,Kommunikationsverbindung,SG3,COM,3155,,TE,,Telefon,X [1P0..1], + 29,Kommunikationsverbindung,SG3,COM,3155,,AJ,,weiteres Telefon,X [1P0..1], + 30,Kommunikationsverbindung,SG3,COM,3155,,AL,,Handy,X [1P0..1], + 31,MP-ID Empfänger,SG2,,,,,,,Muss, + 32,MP-ID Empfänger,SG2,NAD,,00011,,,,Muss, + 33,MP-ID Empfänger,SG2,NAD,3035,00011,MR,,Nachrichtenempfänger,X, + 34,MP-ID Empfänger,SG2,NAD,3039,00011,,,MP-ID,X, + 35,MP-ID Empfänger,SG2,NAD,3055,00011,9,,GS1,X, + 36,MP-ID Empfänger,SG2,NAD,3055,,293,,"DE, BDEW(Bundesverband derEnergie- undWasserwirtschaft e.V.)",X, + 37,Vorgang,SG4,,,,,,,Muss, + 38,Vorgang,SG4,IDE,,00020,,,,Muss, + 39,Vorgang,SG4,IDE,7495,00020,24,,Transaktion,X, + 40,Vorgang,SG4,IDE,7402,00020,,,Vorgangsnummer,X, + 41,Beginn zum,SG4,DTM,,00024,,,,Muss, + 42,Beginn zum,SG4,DTM,2005,00024,92,,Datum Vertragsbeginn,X, + 43,Beginn zum,SG4,DTM,2380,00024,,,"Datum oder Uhrzeit oderZeitspanne, Wert",X [UB1] ∧ [528],[528] Hinweis: Es ist das Datum/ Daten aus der Anfrage zu verwenden + 44,Beginn zum,SG4,DTM,2379,00024,303,,CCYYMMDDHHMMZZZ,X, + 45,"Änderung zum, Gültigkeit, Beginndatum",SG4,DTM,,00027,,,,Muss, + 46,"Änderung zum, Gültigkeit, Beginndatum",SG4,DTM,2005,00027,157,,"Gültigkeit, Beginndatum",X, + 47,"Änderung zum, Gültigkeit, Beginndatum",SG4,DTM,2380,00027,,,"Datum oder Uhrzeit oderZeitspanne, Wert",X [UB1] ∧ [528],[528] Hinweis: Es ist das Datum/ Daten aus der Anfrage zu verwenden + 48,"Änderung zum, Gültigkeit, Beginndatum",SG4,DTM,2379,00027,303,,CCYYMMDDHHMMZZZ,X, + 49,Transaktionsgrund,SG4,STS,,00037,,,,Muss [2061],[2061] Segment bzw. Segmentgruppe ist genau einmal je SG4 IDE (Vorgang) anzugeben + 50,Transaktionsgrund,SG4,STS,9015,00037,7,,Transaktionsgrund,X, + 51,Transaktionsgrund,SG4,STS,9013,00037,ZF8,,Bila.rel. Anfrage an NBmit Abhängigkeiten,X, + 52,Status der Antwort,SG4,STS,,00039,,,,Muss [249],[249] Innerhalb eines SG4 IDE müssen alle DE1131 der SG4 STS+E01 den identischen Wert enthalten + 53,Status der Antwort,SG4,STS,9015,00039,E01,,Status der Antwort,X, + 54,Status der Antwort,SG4,STS,9013,00039,,,Code des Prüfschritts,X, + 55,Status der Antwort,SG4,STS,1131,00039,Codeliste Strom Nr.S_0025Codeliste Strom Nr.S_0026,,S_0025S_0026,X [4]X [241],"[4] Wenn MP-ID in SG2 NAD+MR (Nachrichtenempfänger) in der Rolle LF + [241] Wenn MP-ID in SG2 NAD+MR (Nachrichtenempfänger) in der Rolle MSB" + 56,Marktlokation,SG5,,,,,,,Muss [2061],[2061] Segment bzw. Segmentgruppe ist genau einmal je SG4 IDE (Vorgang) anzugeben + 57,Marktlokation,SG5,LOC,,00051,,,,Muss, + 58,Marktlokation,SG5,LOC,3227,00051,Z16,,Marktlokation,X, + 59,Marktlokation,SG5,LOC,3225,00051,,,ID der Marktlokation,X [950],[950] Format: Marktlokations-ID + 60,Prüfidentifikator,SG6,,,,,,,Muss, + 61,Prüfidentifikator,SG6,RFF,,00057,,,,Muss, + 62,Prüfidentifikator,SG6,RFF,1153,00057,Z13,,Prüfidentifikator,X, + 63,Prüfidentifikator,SG6,RFF,1154,00057,55156,,SDÄ Strom / Bila.rel.Anfrage an NB mitAbhängigkeiten,, + 64,Referenz Vorgangsnummer (aus Anfragenachricht),SG6,,,,,,,Muss, + 65,Referenz Vorgangsnummer (aus Anfragenachricht),SG6,RFF,,00058,,,,Muss, + 66,Referenz Vorgangsnummer (aus Anfragenachricht),SG6,RFF,1153,00058,TN,,Transaktions-Referenznummer,X, + 67,Referenz Vorgangsnummer (aus Anfragenachricht),SG6,RFF,1154,00058,,,Vorgangsnummer,X, + 68,Daten der Marktlokation,SG8,,,,,,,Muss [2061],[2061] Segment bzw. Segmentgruppe ist genau einmal je SG4 IDE (Vorgang) anzugeben + 69,Daten der Marktlokation,SG8,SEQ,,00103,,,,Muss, + 70,Daten der Marktlokation,SG8,SEQ,1229,00103,Z01,,Daten der Marktlokation,X, + 71,Referenz auf die ID der Marktlokation,SG8,RFF,,00104,,,,Muss, + 72,Referenz auf die ID der Marktlokation,SG8,RFF,1153,00104,Z18,,Marktlokation,X, + 73,Referenz auf die ID der Marktlokation,SG8,RFF,1154,00104,,,ID der Marktlokation,X [950],[950] Format: Marktlokations-ID + 74,Arbeit / Leistung für tagesparameterabhängige Marktlokation,SG9,,,,,,,Muss [101],[101] Wenn SG10 CCI+++ZA6 (Prognosegrundlage der Marktlokation: Prognose auf Basis von Profilen) CAV+E14/ Z36 (TLP/ TEP/ TEP mit Ref. messung) in dieser SG8 vorhanden + 75,Arbeit / Leistung für tagesparameterabhängige Marktlokation,SG9,QTY,,00105,,,,Muss, + 76,Arbeit / Leistung für tagesparameterabhängige Marktlokation,SG9,QTY,6063,00105,Z10,,Leistung derMarktlokation,X [102], + 77,Arbeit / Leistung für tagesparameterabhängige Marktlokation,SG9,QTY,6063,,265,,VeranschlagteJahresmenge Gesamt/Jahresverbrauchsprognose für spezifische Arbeitfürtagesparameterabhängige Marktlokation,X, + 78,Arbeit / Leistung für tagesparameterabhängige Marktlokation,SG9,QTY,6063,,Z08,,"Angepasste elektrischeArbeit nach Anhang Dder VDN-Richtlinie""Lastprofile fürunterbrechbareVerbrauchseinrichtungen""",X,[102] Wenn SG10 CCI+++ZA6 (Prognosegrundlage der Marktlokation: Prognose auf Basis von Profilen) CAV+Z36 (TEP mit Ref.messung) in dieser SG8 vorhanden + 79,Arbeit / Leistung für tagesparameterabhängige Marktlokation,SG9,QTY,6060,00105,,,Menge,X [902],[902] Format: Möglicher Wert: ≥ 0 + 80,Arbeit / Leistung für tagesparameterabhängige Marktlokation,SG9,QTY,6411,00105,Z16,,kWh/K (Kilowatt-Stunde/Kelvin),X [103], + 81,Arbeit / Leistung für tagesparameterabhängige Marktlokation,SG9,QTY,6411,,KWH,,Kilowattstunde,X [104], + 82,Arbeit / Leistung für tagesparameterabhängige Marktlokation,SG9,QTY,6411,,KWT,,Kilowatt,X [105],"[103] Wenn SG9 QTY+265 (Arbeit / Leistung für tagesparameterabhängig e Marktlokation: Veranschlagte Jahresmenge Gesamt) in dieser SG8 vorhanden + [104] Wenn SG9 QTY+Z08 (Arbeit / Leistung für tagesparameterabhängige Marktlokation: angepasste elektrische Arbeit nach Anhang D) in dieser SG8 vorhanden + [105] Wenn SG9 QTY+Z10 (Arbeit / Leistung für tagesparameterabhängige Marktlokation: Leistung der Marktlokation) in dieser SG8 vorhanden" + 83,Veranschlagte Jahresmenge gesamt,SG9,,,,,,,Muss [106]Soll [241] ∧[248],"[106] Wenn in dieser SG8 SEQ+Z01 SG10 CCI+++ZA6 (Prognosegrundlage der Marktlokation: Prognose auf Basis von Profilen) CAV+E02 (SLP/SEP) vorhanden + [241] Wenn MP-ID in SG2 NAD+MR (Nachrichtenempfänger) in der Rolle MSB + [248] Wenn die Inbetriebnahme der verbrauchenden Marktlokation innerhalb der letzten drei Jahre war und die Energie der Marktlokation mit iMS ausgestatteten Messlokationen erfolgt " + 84,Veranschlagte Jahresmenge gesamt,SG9,QTY,,00106,,,,Muss, + 85,Veranschlagte Jahresmenge gesamt,SG9,QTY,6063,00106,31,,VeranschlagteJahresmenge Gesamt,X, + 86,Veranschlagte Jahresmenge gesamt,SG9,QTY,6060,00106,,,Mengenangabe,X [902] ∧ [937],"[902] Format: Möglicher Wert: ≥ 0 + [937] Format: keine Nachkommastelle" + 87,Veranschlagte Jahresmenge gesamt,SG9,QTY,6411,00106,KWH,,Kilowattstunde,X, + 88,Lieferrichtung,SG10,,,,,,,Muss, + 89,Lieferrichtung,SG10,CCI,,00110,,,,Muss, + 90,Lieferrichtung,SG10,CCI,7059,00110,Z30,,Lieferrichtung,X, + 91,Lieferrichtung,SG10,CCI,7037,00110,Z06,,Erzeugung,X, + 92,Lieferrichtung,SG10,CCI,7037,,Z07,,Verbrauch,X, + 93,Regelzone,SG10,,,,,,,Muss [4],"[4] Wenn MP-ID in SG2 NAD+MR (Nachrichtenempfänger) in der Rolle LF + [5] Wenn MP-ID in SG2 NAD+MS (Nachrichtenabsender) in der Rolle LF" + 94,Regelzone,SG10,CCI,,00116,,,,Muss, + 95,Regelzone,SG10,CCI,7059,00116,Z18,,Regelzone,X, + 96,Regelzone,SG10,CCI,7037,00116,,,Regelzone,X, + 97,Bilanzierungsgebiet,SG10,,,,,,,Muss [4],"[4] Wenn MP-ID in SG2 NAD+MR (Nachrichtenempfänger) in der Rolle LF + [5] Wenn MP-ID in SG2 NAD+MS (Nachrichtenabsender) in der Rolle LF" + 98,Bilanzierungsgebiet,SG10,CCI,,00118,,,,Muss, + 99,Bilanzierungsgebiet,SG10,CCI,7059,00118,Z20,,Bilanzierungsgebiet,X, + 100,Bilanzierungsgebiet,SG10,CCI,7037,00118,,,Bilanzierungsgebiet,X, + 101,Verbrauchsaufteilung für temperaturabhängige Marktlokation,SG10,,,,,,,Muss [4] ∧ [89]∧ [106],"[4] Wenn MP-ID in SG2 NAD+MR (Nachrichtenempfänger) in der Rolle LF + [89] Wenn im SG8 SEQ+Z01 (Daten der Marktlokation) das SG10 CCI+++ZA6 (Prognosegrundlage der Marktlokation: Prognose auf Basis von Profilen) CAV+E14 (TLP/TEP) vorhanden + [106] Wenn in dieser SG8 SEQ+Z01 SG10 CCI+++ZA6 (Prognosegrundlage der Marktlokation: Prognose auf" + 102,Verbrauchsaufteilung für temperaturabhängige Marktlokation,SG10,CCI,,00119,,,,Muss, + 103,Verbrauchsaufteilung für temperaturabhängige Marktlokation,SG10,CCI,7037,00119,E17,,Verbrauchsaufteilung (in%) fürtemperaturabhängigeMarktlokation,X, + 104,Verbrauchsaufteilung für temperaturabhängige Marktlokation,SG10,CAV,,00120,,,,Muss, + 105,Verbrauchsaufteilung für temperaturabhängige Marktlokation,SG10,CAV,7111,00120,Z22,,Verbrauchsaufteilung in%,X, + 106,Verbrauchsaufteilung für temperaturabhängige Marktlokation,SG10,CAV,7110,00120,,,Verbrauchsaufteilung in %,X [902],[902] Format: Möglicher Wert: ≥ 0 + 107,Zeitreihentyp,SG10,,,,,,,Muss [4] ∧([2061] ⊻ ([90]∧ [2096])),"[4] Wenn MP-ID in SG2 NAD+MR (Nachrichtenempfänger) in der Rolle LF + [5] Wenn MP-ID in SG2 NAD+MS (Nachrichtenabsender) in der Rolle LF + [90] Wenn SG10 CCI+++ZA6 (Prognosegrundlage der Marktlokation: Prognose auf Basis von Profilen) einmal mit CAV+E14 (TLP/TEP) und einmal mit CAV+E02 (SLP/SEP) in dieser SG8 vorhanden + [2061] Segment bzw. Segmentgruppe ist genau einmal je SG4 IDE (Vorgang) anzugeben + [2096] Segmentgruppe ist genau zweimal je SG4 IDE anzugeben" + 108,Zeitreihentyp,SG10,CCI,,00121,,,,Muss, + 109,Zeitreihentyp,SG10,CCI,7059,00121,15,,Struktur,X, + 110,Zeitreihentyp,SG10,CCI,7037,00121,Z21,,Summenzeitreihentyp,X, + 111,Zeitreihentyp,SG10,CAV,,00122,,,,Muss, + 112,Zeitreihentyp,SG10,CAV,7111,00122,,,Code des Zeitreihentyps,X, + 113,Messtechnische Einordnung der Marktlokation,SG10,,,,,,,Muss [4],[4] Wenn MP-ID in SG2 NAD+MR (Nachrichtenempfänger) in der Rolle LF + 114,Messtechnische Einordnung der Marktlokation,SG10,CCI,,00126,,,,Muss, + 115,Messtechnische Einordnung der Marktlokation,SG10,CCI,7037,00126,Z83,,MesstechnischeEinordnung derMarktlokation,X, + 116,Messtechnische Einordnung der Marktlokation,SG10,CAV,,00127,,,,Muss, + 117,Messtechnische Einordnung der Marktlokation,SG10,CAV,7111,00127,Z52,,iMS,X, + 118,Messtechnische Einordnung der Marktlokation,SG10,CAV,7111,,Z53,,kME / mME,X, + 119,Messtechnische Einordnung der Marktlokation,SG10,CAV,7111,,Z68,,keine Messung,X [20],[20] Wenn SG8 SEQ+Z01 (Daten der Marktlokation) SG10 CCI+Z30++Z07 (Verbrauch) vorhanden + 120,Aggregationsverantwortung in MaBiS,SG10,,,,,,,Muss, + 121,Aggregationsverantwortung in MaBiS,SG10,CCI,,00128,,,,Muss, + 122,Aggregationsverantwortung in MaBiS,SG10,CCI,7059,00128,6,,Verantwortlicher,X, + 123,Aggregationsverantwortung in MaBiS,SG10,CCI,7037,00128,ZA8,,NB,X, + 124,Aggregationsverantwortung in MaBiS,SG10,CCI,7037,,ZA9,,ÜNB,X, + 125,Prognosegrundlage der Marktlokation,SG10,,,,,,,Muss, + 126,Prognosegrundlage der Marktlokation,SG10,CCI,,00130,,,,Muss, + 127,Prognosegrundlage der Marktlokation,SG10,CCI,7037,00130,ZC0,,Prognose auf Basis vonWerten,X, + 128,Prognosegrundlage der Marktlokation,SG10,CCI,7037,,ZA6,,Prognose auf Basis vonProfilen,X, + 129,Details der Prognosegrundlage,SG10,CAV,,00131,,,,Muss [21] ∧([2182] ⊻ ([90]∧ [2183])),"[21] Wenn SG10 CCI+++ZA6 (Prognose auf Basis von Profilen) in dieser SG8 vorhanden + [90] Wenn SG10 CCI+++ZA6 (Prognosegrundlage der Marktlokation: Prognose auf Basis von Profilen) einmal mit CAV+E14 (TLP/TEP) und einmal mit CAV+E02 (SLP/SEP) in dieser SG8 vorhanden + [2182] Segmentgruppe ist genau einmal je SG8 SEQ+Z01 (Daten der Marktlokation)" + 130,Details der Prognosegrundlage,SG10,CAV,7111,00131,E02,,SLP/SEP,X [6P0..1] ⊻[7P1..1], + 131,Details der Prognosegrundlage,SG10,CAV,7111,,E14,,TLP/TEP,X [6P0..1], + 132,Details der Prognosegrundlage,SG10,CAV,7111,,Z36,,TEP mitReferenzmessung,X [12P0..1], + 133,Wahlrecht der Prognosegrundlage der Marktlokation,SG10,,,,,,,Muss [4] ∧ [20]∧ [244],"[4] Wenn MP-ID in SG2 NAD+MR (Nachrichtenempfänger) in der Rolle LF + [5] Wenn MP-ID in SG2 NAD+MS (Nachrichtenabsender) in der Rolle LF + [20] Wenn SG8 SEQ+Z01 (Daten der Marktlokation) SG10 CCI+Z30++Z07 (Verbrauch) vorhanden + [244] Wenn SG10 CCI+6++ZA9 (Aggreg.verantw. ÜNB) in dieser SG8 vorhanden" + 134,Wahlrecht der Prognosegrundlage der Marktlokation,SG10,CCI,,00134,,,,Muss, + 135,Wahlrecht der Prognosegrundlage der Marktlokation,SG10,CCI,7037,00134,Z84,,Wahlrecht derPrognosegrundlage,X, + 136,Wahlrecht der Prognosegrundlage der Marktlokation,SG10,CAV,,00135,,,,Muss, + 137,Wahlrecht der Prognosegrundlage der Marktlokation,SG10,CAV,7111,00135,Z54,,Wahlrecht durch LFgegeben,X, + 138,Wahlrecht der Prognosegrundlage der Marktlokation,SG10,CAV,7111,,ZE2,,Wahlrecht durch LF nichtgegeben,X, + 139,Grund für nicht vorhandenes Wahlrecht der Prognosegrundlage der Marktlokation,SG10,CAV,,00136,,,,Muss [247],[247] Wenn CAV+ZE2 (Wahlrecht durch LF nicht gegeben) vorhanden + 140,Grund für nicht vorhandenes Wahlrecht der Prognosegrundlage der Marktlokation,SG10,CAV,7111,00136,Z55,,Wahlrecht nichtvorhanden wegenVerbrauch > 10.000kWh/a,X [1P0..1], + 141,Grund für nicht vorhandenes Wahlrecht der Prognosegrundlage der Marktlokation,SG10,CAV,7111,,ZC1,,Wahlrecht nichtvorhanden wegenEigenverbrauch,X [1P0..1], + 142,Grund für nicht vorhandenes Wahlrecht der Prognosegrundlage der Marktlokation,SG10,CAV,7111,,ZD2,,Wahlrecht nichtvorhanden wegentagesparameterabhängigem Verbrauch,X [1P0..1], + 143,Grund für nicht vorhandenes Wahlrecht der Prognosegrundlage der Marktlokation,SG10,CAV,7111,,ZE3,,Wahlrecht nichtvorhanden wegen § 14aEnWG,X [1P0..1], + 144,Abwicklungsmodell,SG10,,,,,,,Muss [20],[20] Wenn SG8 SEQ+Z01 (Daten der Marktlokation) SG10 CCI+Z30++Z07 (Verbrauch) vorhanden + 145,Abwicklungsmodell,SG10,CCI,,00153,,,,Muss, + 146,Abwicklungsmodell,SG10,CCI,7059,00153,ZA2,,Abwicklungsmodell,X, + 147,Abwicklungsmodell,SG10,CCI,7037,00153,ZE9,,"Modell 1 ""Bilanzierungan der Marktlokation""",X, + 148,Abwicklungsmodell,SG10,CCI,7037,,ZF0,,"Modell 2 ""Bilanzierungim Bilanzierungsgebiet(BG) des LPB""",X, + 149,Profildaten,SG8,,,,,,,Muss [119],[119] Wenn in der SG8 SEQ+Z01 SG10 CCI+++ZA6 (Prognosegrundlage der Marktlokation: Prognose auf Basis von Profilen) CAV+E02 (SLP/SEP) vorhanden + 150,Profildaten,SG8,SEQ,,00376,,,,Muss, + 151,Profildaten,SG8,SEQ,1229,00376,Z21,,Profildaten,X, + 152,Referenz auf die ID der Marktlokation,SG8,RFF,,00378,,,,Muss, + 153,Referenz auf die ID der Marktlokation,SG8,RFF,1153,00378,Z18,,Marktlokation,X, + 154,Referenz auf die ID der Marktlokation,SG8,RFF,1154,00378,,,ID einer Marktlokation,X [950],[950] Format: Marktlokations-ID + 155,Normiertes Profil,SG10,,,,,,,Muss, + 156,Normiertes Profil,SG10,CCI,,00380,,,,Muss, + 157,Normiertes Profil,SG10,CCI,7059,00380,Z02,,Standardlastprofil,X [20], + 158,Normiertes Profil,SG10,CCI,7059,,Z04,,Standardeinspeiseprofil,X [54],"[20] Wenn SG8 SEQ+Z01 (Daten der Marktlokation) SG10 CCI+Z30++Z07 (Verbrauch) vorhanden + [54] Wenn SG8 SEQ+Z01" + 159,Normiertes Profil,SG10,CCI,7037,00380,E01,,synthetisches Verfahren,X, + 160,Normiertes Profil,SG10,CCI,7037,,Z10,,analytisches Verfahren,X [332],[332] Wenn im SG8 SEQ+Z01 (Daten der Marktlokation) das SG10 CCI+6++ZA9 (Aggreg. verantw. ÜNB) nicht vorhanden + 161,Normiertes Profil,SG10,CAV,,00381,,,,Muss, + 162,Normiertes Profil,SG10,CAV,7111,00381,,,Code des Normierten Profils,X, + 163,Profilschardaten,SG8,,,,,,,Muss [89],[89] Wenn im SG8 SEQ+Z01 (Daten der Marktlokation) das SG10 CCI+++ZA6 (Prognosegrundlage der Marktlokation: Prognose auf Basis von Profilen) CAV+E14 (TLP/TEP) vorhanden + 164,Profilschardaten,SG8,SEQ,,00387,,,,Muss, + 165,Profilschardaten,SG8,SEQ,1229,00387,Z08,,Profilschardaten,X, + 166,Referenz auf die ID der Marktlokation,SG8,RFF,,00389,,,,Muss, + 167,Referenz auf die ID der Marktlokation,SG8,RFF,1153,00389,Z18,,Marktlokation,X, + 168,Referenz auf die ID der Marktlokation,SG8,RFF,1154,00389,,,ID einer Marktlokation,X [950],[950] Format: Marktlokations-ID + 169,Profilschar,SG10,,,,,,,Muss, + 170,Profilschar,SG10,CCI,,00397,,,,Muss, + 171,Profilschar,SG10,CCI,7037,00397,Z12,,Profilschar,X, + 172,Profilschar,SG10,CAV,,00398,,,,Muss, + 173,Profilschar,SG10,CAV,7111,00398,,,Code der Profilschar,X, + 174,Normiertes Profil,SG10,,,,,,,Muss, + 175,Normiertes Profil,SG10,CCI,,00399,,,,Muss, + 176,Normiertes Profil,SG10,CCI,7059,00399,Z03,,tagesparameterabhängiges Lastprofil,X [20], + 177,Normiertes Profil,SG10,CCI,7059,,Z05,,tagesparameterabhängiges Einspeiseprofil,X [54],"[20] Wenn SG8 SEQ+Z01 (Daten der Marktlokation) SG10 CCI+Z30++Z07 (Verbrauch) vorhanden + [54] Wenn SG8 SEQ+Z01 (Daten der Marktlokation) SG10 CCI+Z30++Z06" + 178,Normiertes Profil,SG10,CCI,7037,00399,E01,,synthetisches Verfahren,X, + 179,Normiertes Profil,SG10,CCI,7037,,Z10,,analytisches Verfahren,X, + 180,Normiertes Profil,SG10,CAV,,00400,,,,Muss, + 181,Normiertes Profil,SG10,CAV,7111,00400,,,Code des Normierten Profils,X, + 182,Klimazone / Temperaturmessstelle,SG10,,,,,,,Muss, + 183,Klimazone / Temperaturmessstelle,SG10,CCI,,00403,,,,Muss, + 184,Klimazone / Temperaturmessstelle,SG10,CCI,7059,00403,Z99,,Messstelle desTagesparameters(derzeit ist nur dieTemperatur ein erlaubterTagesparameter),X, + 185,Klimazone / Temperaturmessstelle,SG10,CCI,7059,,ZA0,,Klimazone desTagesparameters(derzeit istTagesparameter),X, + 186,Klimazone / Temperaturmessstelle,SG10,CCI,7037,00403,,,ID Klimazone /Temperaturmessstelle,X, + 187,Klimazone / Temperaturmessstelle,SG10,CCI,1131,00403,,,Dienstanbieter,X [58],[58] Wenn in diesem CCI das DE3055 mit dem Code 293 vorhanden + 188,Klimazone / Temperaturmessstelle,SG10,CCI,3055,00403,89,,Vergeben vom Händler(hier Netzbetreiber),X, + 189,Klimazone / Temperaturmessstelle,SG10,CCI,3055,,293,,"DE, BDEW(Bundesverband derEnergie- undWasserwirtschaft e.V.)",X, + 190,Referenzprofildaten,SG8,,,,,,,Muss [54] ∧[265],"[54] Wenn SG8 SEQ+Z01 (Daten der Marktlokation) SG10 CCI+Z30++Z06 (Lieferrichtung: Erzeugung) vorhanden + [265] Wenn im SG8 SEQ+Z01 (Daten der Marktlokation) das SG10 CCI+++ZA6 (Prognosegrundlage der Marktlokation: Prognose auf Basis von Profilen) CAV+Z36 (TEP m. Referenzmessung) vorhanden" + 191,Referenzprofildaten,SG8,SEQ,,00411,,,,Muss, + 192,Referenzprofildaten,SG8,SEQ,1229,00411,Z38,,Referenzprofildaten,X, + 193,Referenz auf die ID der Marktlokation,SG8,RFF,,00413,,,,Muss, + 194,Referenz auf die ID der Marktlokation,SG8,RFF,1153,00413,Z18,,Marktlokation,X, + 195,Referenz auf die ID der Marktlokation,SG8,RFF,1154,00413,,,ID einer Marktlokation,X [950],[950] Format: Marktlokations-ID + 196,Referenzprofil,SG10,,,,,,,Muss, + 197,Referenzprofil,SG10,CCI,,00415,,,,Muss, + 198,Referenzprofil,SG10,CCI,7059,00415,Z05,,tagesparameterabhängiges Einspeiseprofil,X, + 199,Referenzprofil,SG10,CAV,,00416,,,,Muss, + 200,Referenzprofil,SG10,CAV,7111,00416,,,Code des Referenzprofils,X, + 201,Nachrichten-Endesegment,,UNT,,00540,,,,Muss, + 202,Nachrichten-Endesegment,,UNT,0074,00540,,,Anzahl der Segmente in einerNachricht,X, + 203,Nachrichten-Endesegment,,UNT,0062,00540,,,Nachrichten-Referenznummer,X, + + ''' +# --- +# name: TestCli.test_kohlrahbi_cli_with_valid_arguments[55182] + ''' + ,Segmentname,Segmentgruppe,Segment,Datenelement,Segment ID,Code,Qualifier,Beschreibung,Bedingungsausdruck,Bedingung + 0,Nachrichten-Kopfsegment,,UNH,,00003,,,,Muss, + 1,Nachrichten-Kopfsegment,,UNH,0062,00003,,,Nachrichten-Referenznummer,X, + 2,Nachrichten-Kopfsegment,,UNH,0065,00003,UTILMD,,Netzanschluss-Stammdaten,X, + 3,Nachrichten-Kopfsegment,,UNH,0052,00003,D,,Entwurfs-Version,X, + 4,Nachrichten-Kopfsegment,,UNH,0054,00003,11A,,Ausgabe 2011 - A,X, + 5,Nachrichten-Kopfsegment,,UNH,0051,00003,UN,,UN/CEFACT,X, + 6,Nachrichten-Kopfsegment,,UNH,0057,00003,Versionsnummer derzugrundeliegendenBDEW-Nachrichtenbeschreibung,,S1.1a,X, + 7,Beginn der Nachricht,,BGM,,00004,,,,Muss, + 8,Beginn der Nachricht,,BGM,1001,00004,E03,,Änderungsmeldungen,X, + 9,Beginn der Nachricht,,BGM,1004,00004,,,Dokumentennummer,X, + 10,Nachrichtendatum,,DTM,,00005,,,,Muss, + 11,Nachrichtendatum,,DTM,2005,00005,137,,Dokumenten-/Nachrichtendatum/-zeit,X, + 12,Nachrichtendatum,,DTM,2380,00005,,,"Datum oder Uhrzeit oderZeitspanne, Wert",X [931][494],"[494] Das hier genannte Datum muss der Zeitpunkt sein, zu dem das Dokument erstellt wurde, oder ein Zeitpunkt, der davor liegt + [931] Format: ZZZ = +00" + 13,Nachrichtendatum,,DTM,2379,00005,303,,CCYYMMDDHHMMZZZ,X, + 14,MP-ID Absender,SG2,,,,,,,Muss, + 15,MP-ID Absender,SG2,NAD,,00008,,,,Muss, + 16,MP-ID Absender,SG2,NAD,3035,00008,MS,,Dokumenten-/Nachrichtenausstellerbzw. -absender,X, + 17,MP-ID Absender,SG2,NAD,3039,00008,,,MP-ID,X, + 18,MP-ID Absender,SG2,NAD,3055,00008,9,,GS1,X, + 19,MP-ID Absender,SG2,NAD,3055,,293,,"DE, BDEW(Bundesverband derEnergie- undWasserwirtschaft e.V.)",X, + 20,Ansprechpartner,SG3,,,,,,,Kann, + 21,Ansprechpartner,SG3,CTA,,00009,,,,Muss, + 22,Ansprechpartner,SG3,CTA,3139,00009,IC,,Informationskontakt,X, + 23,Ansprechpartner,SG3,CTA,3412,00009,,,Name vom Ansprechpartner,X, + 24,Kommunikationsverbindung,SG3,COM,,00010,,,,Muss, + 25,Kommunikationsverbindung,SG3,COM,3148,00010,,,Nummer / Adresse,X (([939][321]) ∨([940][322])) ∧[514],"[321] Wenn im DE3155 in demselben COM der Code EM vorhanden ist + [322] Wenn im DE3155 in demselben COM der Code TE / FX / AJ / AL vorhanden ist + [514] Hinweis: Es darf nur eine Information im DE3148 übermittelt werden + [939] Format: Die Zeichenkette muss die Zeichen @ und . enthalten + [940] Format: Die Zeichenkette muss mit dem Zeichen + beginnen und danach dürfen nur noch Ziffern folgen" + 26,Kommunikationsverbindung,SG3,COM,3155,00010,EM,,Elektronische Post,X [1P0..1], + 27,Kommunikationsverbindung,SG3,COM,3155,,FX,,Telefax,X [1P0..1], + 28,Kommunikationsverbindung,SG3,COM,3155,,TE,,Telefon,X [1P0..1], + 29,Kommunikationsverbindung,SG3,COM,3155,,AJ,,weiteres Telefon,X [1P0..1], + 30,Kommunikationsverbindung,SG3,COM,3155,,AL,,Handy,X [1P0..1], + 31,MP-ID Empfänger,SG2,,,,,,,Muss, + 32,MP-ID Empfänger,SG2,NAD,,00011,,,,Muss, + 33,MP-ID Empfänger,SG2,NAD,3035,00011,MR,,Nachrichtenempfänger,X, + 34,MP-ID Empfänger,SG2,NAD,3039,00011,,,MP-ID,X, + 35,MP-ID Empfänger,SG2,NAD,3055,00011,9,,GS1,X, + 36,MP-ID Empfänger,SG2,NAD,3055,,293,,"DE, BDEW(Bundesverband derEnergie- undWasserwirtschaft e.V.)",X, + 37,Vorgang,SG4,,,,,,,Muss, + 38,Vorgang,SG4,IDE,,00020,,,,Muss, + 39,Vorgang,SG4,IDE,7495,00020,24,,Transaktion,X, + 40,Vorgang,SG4,IDE,7402,00020,,,Vorgangsnummer,X, + 41,Beginn zum,SG4,DTM,,00024,,,,, + 42,Beginn zum,SG4,DTM,2005,00024,92,,Datum Vertragsbeginn,, + 43,Beginn zum,SG4,DTM,2380,00024,,,"Datum oder Uhrzeit oderZeitspanne, Wert",,[528] Hinweis: Es ist das Datum/ Daten aus der Anfrage zu verwenden + 44,Beginn zum,SG4,DTM,2379,00024,303,,CCYYMMDDHHMMZZZ,, + 45,"Änderung zum, Gültigkeit, Beginndatum",SG4,DTM,,00027,,,,, + 46,"Änderung zum, Gültigkeit, Beginndatum",SG4,DTM,2005,00027,157,,"Gültigkeit, Beginndatum",, + 47,"Änderung zum, Gültigkeit, Beginndatum",SG4,DTM,2380,00027,,,"Datum oder Uhrzeit oderZeitspanne, Wert",,[528] Hinweis: Es ist das Datum/ Daten aus der Anfrage zu verwenden + 48,"Änderung zum, Gültigkeit, Beginndatum",SG4,DTM,2379,00027,303,,CCYYMMDDHHMMZZZ,, + 49,Transaktionsgrund,SG4,STS,,00037,,,,Muss [2061],[2061] Segment bzw. Segmentgruppe ist genau einmal je SG4 IDE (Vorgang) anzugeben + 50,Transaktionsgrund,SG4,STS,9015,00037,7,,Transaktionsgrund,X, + 51,Transaktionsgrund,SG4,STS,9013,00037,ZJ1,,Anfrage der komplexenMarktlokationsstruktur,X, + 52,Status der Antwort,SG4,STS,,00039,,,,Muss [249],[249] Innerhalb eines SG4 IDE müssen alle DE1131 der SG4 STS+E01 den identischen Wert enthalten + 53,Status der Antwort,SG4,STS,9015,00039,E01,,Status der Antwort,X, + 54,Status der Antwort,SG4,STS,9013,00039,,,Code des Prüfschritts,X, + 55,Status der Antwort,SG4,STS,1131,00039,Codeliste Strom Nr.S_0027Codeliste Strom Nr.S_0101,,S_0027S_0101,X, + 56,Netzlokation,SG5,,,,,,,,"[46] Wenn ID für Objekt vergeben wurde + [683] Hinweis: Es sind alle ID der Netzlokationen, welche der im SG5 LOC+Z16 angegebenen Marktlokation aktuell und / oder zukünftig vorgelagert sind anzugeben. Zudem ist über das DE5479 mit der" + 57,Netzlokation,SG5,LOC,,00050,,,,, + 58,Netzlokation,SG5,LOC,3227,00050,Z18,,Netzlokation,, + 59,Netzlokation,SG5,LOC,3225,00050,,,ID der Netzlokation,,[960] Format: Netzlokations-ID + 60,Netzlokation,SG5,LOC,5479,00050,Z01,,Lokationszuordnungunverändert,, + 61,Netzlokation,SG5,LOC,5479,,Z02,,Lokationszuordnungbeginnt,, + 62,Netzlokation,SG5,LOC,5479,,Z03,,Lokationszuordnungendet,, + 63,Marktlokation,SG5,,,,,,,Muss [2061],[2061] Segment bzw. Segmentgruppe ist genau einmal je SG4 IDE (Vorgang) anzugeben + 64,Marktlokation,SG5,LOC,,00051,,,,Muss, + 65,Marktlokation,SG5,LOC,3227,00051,Z16,,Marktlokation,X, + 66,Marktlokation,SG5,LOC,3225,00051,,,ID der Marktlokation,X [950],[950] Format: Marktlokations-ID + 67,Technische Ressource,SG5,,,,,,,,"[46] Wenn ID für Objekt vergeben wurde + [684] Hinweis: Es sind alle ID der Technischen Ressourcen, welche der im LOC+Z16 angegebenen Marktlokation aktuell und / oder zukünftig zugehören anzugeben. Zudem ist über das DE5479 mit der Angabe des entsprechenden Codes der Zustand der Technischen Ressource zu beschreiben + [694] Hinweis: Wenn in einer Marktlokation eine ID für eine Technischen Ressource vergeben wird, müssen für alle ggf. weitere Technische Ressourcen in der Marktlokation ID vergeben werden." + 68,Technische Ressource,SG5,LOC,,00052,,,,, + 69,Technische Ressource,SG5,LOC,3227,00052,Z20,,Technische Ressource,, + 70,Technische Ressource,SG5,LOC,3225,00052,,,ID der Technischen Ressource,,[922] Format: TR-ID + 71,Technische Ressource,SG5,LOC,5479,00052,Z01,,Lokationszuordnungunverändert,, + 72,Technische Ressource,SG5,LOC,5479,,Z02,,Lokationszuordnungbeginnt,, + 73,Technische Ressource,SG5,LOC,5479,,Z03,,Lokationszuordnungendet,, + 74,Steuerbare Ressource,SG5,,,,,,,,"[46] Wenn ID für Objekt vergeben wurde + [685] Hinweis: Es sind alle ID der Steuerbaren Ressourcen, welche der im LOC+Z20 angegebenen Technischen Ressourcen aktuell und / oder zukünftig zugeordnet sind anzugeben. Zudem ist über das DE5479 mit der Angabe des entsprechenden Codes" + 75,Steuerbare Ressource,SG5,LOC,,00053,,,,, + 76,Steuerbare Ressource,SG5,LOC,3227,00053,Z19,,Steuerbare Ressource,, + 77,Steuerbare Ressource,SG5,LOC,3225,00053,,,ID der Steuerbaren Ressource,,[961] Format: SR-ID + 78,Steuerbare Ressource,SG5,LOC,5479,00053,Z01,,Lokationszuordnungunverändert,, + 79,Steuerbare Ressource,SG5,LOC,5479,,Z02,,Lokationszuordnungbeginnt,, + 80,Steuerbare Ressource,SG5,LOC,5479,,Z03,,Lokationszuordnungendet,, + 81,Tranche,SG5,,,,,,,,"[166] Wenn vorhanden + [686] Hinweis: Es sind alle ID der Tranchen, welche dem LF an der im LOC+Z16 angegebenen Marktlokation die aktuell und / oder zukünftig zugeordnet sind anzugeben." + 82,Tranche,SG5,LOC,,00054,,,,, + 83,Tranche,SG5,LOC,3227,00054,Z21,,Tranche,, + 84,Tranche,SG5,LOC,3225,00054,,,ID der Tranche,,[950] Format: Marktlokations-ID + 85,Messlokation,SG5,,,,,,,,"[399] Wenn im SG8 SEQ+Z78 RFF+Z31 (Referenz auf die Lokationsbündelstruktur) im DE1153 der Code Z31 (Lokationsbündelstruktur ) vorhanden ist und im DE1154 (ID der Lokationsbündelstruktur) der Code 9992 00000 001 8 nicht vorhanden ist. + [687] Hinweis: Es sind alle Messlokationen zu nennen, die für die Energiemengenermittlun g aktuell und / oder zukünftig der im LOC+Z16 angegebenen Marktlokation notwendig sind. Zudem ist über das DE5479 mit der Angabe des" + 86,Messlokation,SG5,LOC,,00055,,,,, + 87,Messlokation,SG5,LOC,3227,00055,Z17,,Messlokation,, + 88,Messlokation,SG5,LOC,3225,00055,,,ID der Messlokation,,[951] Format: Zählpunktbezeichnung + 89,Messlokation,SG5,LOC,5479,00055,Z01,,Lokationszuordnungunverändert,, + 90,Messlokation,SG5,LOC,5479,,Z02,,Lokationszuordnungbeginnt,, + 91,Messlokation,SG5,LOC,5479,,Z03,,Lokationszuordnungendet,, + 92,Prüfidentifikator,SG6,,,,,,,Muss, + 93,Prüfidentifikator,SG6,RFF,,00057,,,,Muss, + 94,Prüfidentifikator,SG6,RFF,1153,00057,Z13,,Prüfidentifikator,X, + 95,Prüfidentifikator,SG6,RFF,1154,00057,55180,,SDÄ Strom / Anfrage derkomplexenMarktlokationsstrukturLF an NB,, + 96,Prüfidentifikator,SG6,RFF,1154,,55181,,SDÄ Strom / Antwort aufAnfrage der komplexenMarktlokationsstrukturNB an LF,, + 97,Prüfidentifikator,SG6,RFF,1154,,55182,,SDÄ Strom / Ablehnungder Anfrage derkomplexenMarktlokationsstrukturNB an LF,X, + 98,Referenz Vorgangsnummer (aus Anfragenachricht),SG6,,,,,,,Muss, + 99,Referenz Vorgangsnummer (aus Anfragenachricht),SG6,RFF,,00058,,,,Muss, + 100,Referenz Vorgangsnummer (aus Anfragenachricht),SG6,RFF,1153,00058,TN,,Transaktions-Referenznummer,X, + 101,Referenz Vorgangsnummer (aus Anfragenachricht),SG6,RFF,1154,00058,,,Vorgangsnummer,X, + 102,Referenz auf die Lokationsbündelstruktur,SG8,,,,,,,,"[309] Wenn DTM+137 (Nachrichtendatum) im DE2380 ≥ 202409302200?+00 + [513] Hinweis: Bei Anwendung dieser Segmentgruppe vor dem 01.10.2024 sind die Codes in diesem Segment noch nicht" + 103,Referenz auf die Lokationsbündelstruktur,SG8,SEQ,,00071,,,,, + 104,Referenz auf die Lokationsbündelstruktur,SG8,SEQ,1229,00071,Z78,,Referenz auf dieLokationsbündelstruktur,, + 105,Referenz auf die Lokationsbündelstruktur,SG8,RFF,,00072,,,,, + 106,Referenz auf die Lokationsbündelstruktur,SG8,RFF,1153,00072,Z31,,Lokationsbündelstruktur,, + 107,Referenz auf die Lokationsbündelstruktur,SG8,RFF,1153,,Z39,,Keine standardisierteLokationsbündelstrukturvorhanden,, + 108,Referenz auf die Lokationsbündelstruktur,SG8,RFF,1154,00072,,,ID der Lokationsbündelstruktur,,"[335] Wenn im SG8 SEQ+Z78 RFF+Z31 ""Referenz auf die Lokationsbündelstruktur "" im DE1153 der Code Z31 ""Lokationsbündelstruktu r"" vorhanden ist" + 109,Referenz auf die Lokationsbündelstruktur,SG8,RFF,1156,00072,,,Fortlaufende Nummer einesLokationsbündels imGeschäftsvorfall,,"[32] Wenn mehr als ein SG8 SEQ+Z78 (Referenz auf die Lokationsbündelstruktur) vorhanden + [914] Format: Möglicher Wert: > 0 + [937] Format: keine Nachkommastelle" + 110,Zuordnung Lokation zum Objektcode des Lokationsbündels,SG8,,,,,,,,"[335] Wenn im SG8 SEQ+Z78 RFF+Z31 ""Referenz auf die Lokationsbündelstruktur "" im DE1153 der Code" + 111,Zuordnung Lokation zum Objektcode des Lokationsbündels,SG8,SEQ,,00073,,,,, + 112,Zuordnung Lokation zum Objektcode des Lokationsbündels,SG8,SEQ,1229,00073,Z58,,Zuordnung Lokation zumObjektcode desLokationsbündels,, + 113,Referenz auf die ID der Netzlokation / Marktlokation / Messlokation / Technischen Ressource,SG8,RFF,,00074,,,,, + 114,Referenz auf die ID der Netzlokation / Marktlokation / Messlokation / Technischen Ressource,SG8,RFF,1153,00074,Z32,,Netzlokation,, + 115,Referenz auf die ID der Netzlokation / Marktlokation / Messlokation / Technischen Ressource,SG8,RFF,1153,,Z18,,Marktlokation,, + 116,Referenz auf die ID der Netzlokation / Marktlokation / Messlokation / Technischen Ressource,SG8,RFF,1153,,Z19,,Messlokation,, + 117,Referenz auf die ID der Netzlokation / Marktlokation / Messlokation / Technischen Ressource,SG8,RFF,1153,,Z37,,Technische Ressource,, + 118,Referenz auf die ID der Netzlokation / Marktlokation / Messlokation / Technischen Ressource,SG8,RFF,1154,00074,,,ID einer Lokation,,"[450] Wenn in demselben RFF der Code Z32 (Netzlokation) im DE1153 vorhanden + [451] Wenn in demselben RFF der Code Z18 (Marktlokation) im DE1153 vorhanden" + 119,Referenz auf den Objektcode in der Lokationsbündelstruktur,SG8,RFF,,00075,,,,,[2313] Je SG8 SEQ+Z58 (Zuordnung Lokation zum Objektcode des Lokationsbündels) genau einmal anzugeben + 120,Referenz auf den Objektcode in der Lokationsbündelstruktur,SG8,RFF,1153,00075,Z33,,Objektcode der Lokationin derLokationsbündelstruktur,, + 121,Referenz auf den Objektcode in der Lokationsbündelstruktur,SG8,RFF,1154,00075,,,Objekt Code,, + 122,Referenz auf den Objektcode in der Lokationsbündelstruktur,SG8,RFF,1156,00075,,,Fortlaufende Nummer einesLokationsbündels imGeschäftsvorfall,,"[32] Wenn mehr als ein SG8 SEQ+Z78 (Referenz auf die Lokationsbündelstruktur) vorhanden + [914] Format: Möglicher Wert: > 0 + [937] Format: keine Nachkommastelle" + 123,Referenz auf die ID der vorgelagerten Netzlokation / Messlokation ,SG8,RFF,,00076,,,,,[290] Wenn der Objektcode im RFF+Z33 (Referenz auf den + 124,Referenz auf die ID der vorgelagerten Netzlokation / Messlokation ,SG8,RFF,1153,00076,Z34,,vorgelagerteMesslokation,, + 125,Referenz auf die ID der vorgelagerten Netzlokation / Messlokation ,SG8,RFF,1153,,Z35,,vorgelagerteNetzlokation,, + 126,Referenz auf die ID der vorgelagerten Netzlokation / Messlokation ,SG8,RFF,1154,00076,,,ID einer Lokation,,"[471] Wenn in demselben RFF der Code Z35 (vorgelagerte Netzlokation) im DE1153 vorhanden + [472] Wenn in demselben RFF der Code Z34 (vorgelagerte Messlokation) im DE1153 vorhanden + [951] Format: Zählpunktbezeichnung + [960] Format: Netzlokations-ID" + 127,Referenz auf die der Technischen Ressource zugeordneten Marktlokation ,SG8,RFF,,00077,,,,,"[290] Wenn der Objektcode im RFF+Z33 (Referenz auf den Objektcode in der Lokationsbündelstruktur) im DE1154 derselben SG8 SEQ+Z58 (Zuordnung Lokation zum Objektcode des Lokationsbündels) in einem weiteren SG8 SEQ+Z58 vorhanden ist + [291] Wenn in derselben SG8 SEQ+Z58 (Zuordnung Lokation zum Objektcode des Lokationsbündels) das" + 128,Referenz auf die der Technischen Ressource zugeordneten Marktlokation ,SG8,RFF,1153,00077,Z16,,zugeordneteMarktlokation,, + 129,Referenz auf die der Technischen Ressource zugeordneten Marktlokation ,SG8,RFF,1154,00077,,,ID der Marktlokation,,[950] Format: Marktlokations-ID + 130,Nachrichten-Endesegment,,UNT,,00540,,,,Muss, + 131,Nachrichten-Endesegment,,UNT,0074,00540,,,Anzahl der Segmente in einerNachricht,X, + 132,Nachrichten-Endesegment,,UNT,0062,00540,,,Nachrichten-Referenznummer,X, + + ''' +# --- +# name: TestCli.test_kohlrahbi_cli_with_valid_arguments[55200] + ''' + ,Segmentname,Segmentgruppe,Segment,Datenelement,Segment ID,Code,Qualifier,Beschreibung,Bedingungsausdruck,Bedingung + 0,Nachrichten-Kopfsegment,,UNH,,00003,,,,Muss, + 1,Nachrichten-Kopfsegment,,UNH,0062,00003,,,Nachrichten-Referenznummer,X, + 2,Nachrichten-Kopfsegment,,UNH,0065,00003,UTILMD,,Netzanschluss-Stammdaten,X, + 3,Nachrichten-Kopfsegment,,UNH,0052,00003,D,,Entwurfs-Version,X, + 4,Nachrichten-Kopfsegment,,UNH,0054,00003,11A,,Ausgabe 2011 - A,X, + 5,Nachrichten-Kopfsegment,,UNH,0051,00003,UN,,UN/CEFACT,X, + 6,Nachrichten-Kopfsegment,,UNH,0057,00003,Versionsnummer derzugrundeliegendenBDEW-Nachrichtenbeschreibung,,S1.1a,X, + 7,Beginn der Nachricht,,BGM,,00004,,,,Muss, + 8,Beginn der Nachricht,,BGM,1001,00004,Z07,,Aktivierung/Deaktivierung vonMaBiS-ZP,X, + 9,Beginn der Nachricht,,BGM,1004,00004,,,Dokumentennummer,X, + 10,Nachrichtendatum,,DTM,,00005,,,,Muss, + 11,Nachrichtendatum,,DTM,2005,00005,137,,Dokumenten-/Nachrichtendatum/-zeit,X, + 12,Nachrichtendatum,,DTM,2380,00005,,,"Datum oder Uhrzeit oderZeitspanne, Wert",X [931] [494],"[494] Das hier genannte Datum muss der Zeitpunkt sein, zu dem das Dokument erstellt wurde, oder ein Zeitpunkt, der davor liegt + [931] Format: ZZZ = +00" + 13,Nachrichtendatum,,DTM,2379,00005,303,,CCYYMMDDHHMMZZZ,X, + 14,MP-ID Absender,SG2,,,,,,,Muss, + 15,MP-ID Absender,SG2,NAD,,00008,,,,Muss, + 16,MP-ID Absender,SG2,NAD,3035,00008,MS,,Dokumenten-/Nachrichtenausstellerbzw. -absender,X, + 17,MP-ID Absender,SG2,NAD,3039,00008,,,MP-ID,X, + 18,MP-ID Absender,SG2,NAD,3055,00008,9,,GS1,X, + 19,MP-ID Absender,SG2,NAD,3055,,293,,"DE, BDEW(Bundesverband derEnergie- undWasserwirtschaft e.V.)",X, + 20,Ansprechpartner,SG3,,,,,,,Kann, + 21,Ansprechpartner,SG3,CTA,,00009,,,,Muss, + 22,Ansprechpartner,SG3,CTA,3139,00009,IC,,Informationskontakt,X, + 23,Ansprechpartner,SG3,CTA,3412,00009,,,Name vom Ansprechpartner,X, + 24,Kommunikationsverbindung,SG3,COM,,00010,,,,Muss, + 25,Kommunikationsverbindung,SG3,COM,3148,00010,,,Nummer / Adresse,X (([939] [321])∨ ([940] [322]))∧ [514],"[321] Wenn im DE3155 in demselben COM der Code EM vorhanden ist + [322] Wenn im DE3155 in demselben COM der Code TE / FX / AJ / AL vorhanden ist + [514] Hinweis: Es darf nur eine Information im DE3148 übermittelt werden + [939] Format: Die Zeichenkette muss die Zeichen @ und . enthalten + [940] Format: Die Zeichenkette muss mit dem Zeichen + beginnen und danach dürfen nur noch Ziffern folgen" + 26,Kommunikationsverbindung,SG3,COM,3155,00010,EM,,Elektronische Post,X [1P0..1], + 27,Kommunikationsverbindung,SG3,COM,3155,,FX,,Telefax,X [1P0..1], + 28,Kommunikationsverbindung,SG3,COM,3155,,TE,,Telefon,X [1P0..1], + 29,Kommunikationsverbindung,SG3,COM,3155,,AJ,,weiteres Telefon,X [1P0..1], + 30,Kommunikationsverbindung,SG3,COM,3155,,AL,,Handy,X [1P0..1], + 31,MP-ID Empfänger,SG2,,,,,,,Muss, + 32,MP-ID Empfänger,SG2,NAD,,00011,,,,Muss, + 33,MP-ID Empfänger,SG2,NAD,3035,00011,MR,,Nachrichtenempfänger,X, + 34,MP-ID Empfänger,SG2,NAD,3039,00011,,,MP-ID,X [280],[280] Nur MP-ID aus Sparte Strom + 35,MP-ID Empfänger,SG2,NAD,3055,00011,9,,GS1,X, + 36,MP-ID Empfänger,SG2,NAD,3055,,293,,"DE, BDEW(Bundesverband derEnergie- undWasserwirtschaft e.V.)",X, + 37,Vorgang,SG4,,,,,,,Muss, + 38,Vorgang,SG4,IDE,,00020,,,,Muss, + 39,Vorgang,SG4,IDE,7495,00020,24,,Transaktion,X, + 40,Vorgang,SG4,IDE,7402,00020,,,Vorgangsnummer,X, + 41,Bilanzierungsbeginn,SG4,DTM,,00029,,,,, + 42,Bilanzierungsbeginn,SG4,DTM,2005,00029,158,,Bilanzierungsbeginn,, + 43,Bilanzierungsbeginn,SG4,DTM,2380,00029,,,"Datum oder Uhrzeit oderZeitspanne, Wert",, + 44,Bilanzierungsbeginn,SG4,DTM,2379,00029,303,,CCYYMMDDHHMMZZZ,, + 45,Bilanzierungsende,SG4,DTM,,00030,,,,Muss, + 46,Bilanzierungsende,SG4,DTM,2005,00030,159,,Bilanzierungsende,X, + 47,Bilanzierungsende,SG4,DTM,2380,00030,,,"Datum oder Uhrzeit oderZeitspanne, Wert",X [UB1], + 48,Bilanzierungsende,SG4,DTM,2379,00030,303,,CCYYMMDDHHMMZZZ,X, + 49,MaBiS-Zählpunkt,SG5,,,,,,,Muss [2061],[2061] Segment bzw. Segmentgruppe ist genau einmal je SG4 IDE (Vorgang) anzugeben + 50,MaBiS-Zählpunkt,SG5,LOC,,00056,,,,Muss, + 51,MaBiS-Zählpunkt,SG5,LOC,3227,00056,Z15,,MaBiS-Zählpunkt,X, + 52,MaBiS-Zählpunkt,SG5,LOC,3225,00056,,,Identifikator,X [951],[951] Format: Zählpunktbezeichnung + 53,Prüfidentifikator,SG6,,,,,,,Muss, + 54,Prüfidentifikator,SG6,RFF,,00057,,,,Muss, + 55,Prüfidentifikator,SG6,RFF,1153,00057,Z13,,Prüfidentifikator,X, + 56,Prüfidentifikator,SG6,RFF,1154,00057,55199,,Redispatch / AktivierungZP LF-AASZR,, + 57,Prüfidentifikator,SG6,RFF,1154,,55200,,Redispatch /Deaktivierung ZP LF-AASZR,X, + 58,Daten der Summenzeitreihe,SG8,,,,,,,,[2061] Segment bzw. Segmentgruppe ist genau einmal je SG4 IDE (Vorgang) anzugeben + 59,Daten der Summenzeitreihe,SG8,SEQ,,00422,,,,, + 60,Daten der Summenzeitreihe,SG8,SEQ,1229,00422,Z22,,Daten derSummenzeitreihe,, + 61,Regelzone,SG10,,,,,,,, + 62,Regelzone,SG10,CCI,,00428,,,,, + 63,Regelzone,SG10,CCI,7059,00428,Z18,,Regelzone,, + 64,Regelzone,SG10,CCI,7037,00428,,,Regelzone,, + 65,Bilanzierungsgebiet,SG10,,,,,,,, + 66,Bilanzierungsgebiet,SG10,CCI,,00429,,,,, + 67,Bilanzierungsgebiet,SG10,CCI,7059,00429,Z20,,Bilanzierungsgebiet,, + 68,Bilanzierungsgebiet,SG10,CCI,7037,00429,,,Bilanzierungsgebiet,, + 69,Bilanzkreis,SG10,,,,,,,, + 70,Bilanzkreis,SG10,CCI,,00430,,,,, + 71,Bilanzkreis,SG10,CCI,7059,00430,Z19,,Bilanzkreis,, + 72,Bilanzkreis,SG10,CCI,7037,00430,,,Bilanzkreis,,[645] Hinweis: Es ist der Bilanzkreis des LF anzugeben + 73,Zeitreihentyp,SG10,,,,,,,, + 74,Zeitreihentyp,SG10,CCI,,00431,,,,, + 75,Zeitreihentyp,SG10,CCI,7059,00431,15,,Struktur,, + 76,Zeitreihentyp,SG10,CCI,7037,00431,Z21,,Summenzeitreihentyp,, + 77,Zeitreihentyp,SG10,CAV,,00432,,,,, + 78,Zeitreihentyp,SG10,CAV,7111,00432,,,Code des Zeitreihentyps,, + 79,Produkt-Daten der Summenzeitreihe,SG8,,,,,,,, + 80,Produkt-Daten der Summenzeitreihe,SG8,SEQ,,00440,,,,, + 81,Produkt-Daten der Summenzeitreihe,SG8,SEQ,1229,00440,Z23,,Produkt-Daten derSummenzeitreihe,, + 82,Produktidentifikation der Summenzeitreihe,SG8,PIA,,00441,,,,, + 83,Produktidentifikation der Summenzeitreihe,SG8,PIA,4347,00441,5,,Produktidentifikation,, + 84,Produktidentifikation der Summenzeitreihe,SG8,PIA,7140,00441,,,Produktidentifikation derSummenzeitreihe,,"[254] Es ist der Code ""AUA"" einzutragen" + 85,Produktidentifikation der Summenzeitreihe,SG8,PIA,7143,00441,Z08,,Medium,, + 86,Nachrichten-Endesegment,,UNT,,00540,,,,Muss, + 87,Nachrichten-Endesegment,,UNT,0074,00540,,,Anzahl der Segmente in einerNachricht,X, + 88,Nachrichten-Endesegment,,UNT,0062,00540,,,Nachrichten-Referenznummer,X, + + ''' +# --- +# name: TestCli.test_kohlrahbi_cli_with_valid_arguments[55213] + ''' + ,Segmentname,Segmentgruppe,Segment,Datenelement,Segment ID,Code,Qualifier,Beschreibung,Bedingungsausdruck,Bedingung + 0,Nachrichten-Kopfsegment,,UNH,,00003,,,,Muss, + 1,Nachrichten-Kopfsegment,,UNH,0062,00003,,,Nachrichten-Referenznummer,X, + 2,Nachrichten-Kopfsegment,,UNH,0065,00003,UTILMD,,Netzanschluss-Stammdaten,X, + 3,Nachrichten-Kopfsegment,,UNH,0052,00003,D,,Entwurfs-Version,X, + 4,Nachrichten-Kopfsegment,,UNH,0054,00003,11A,,Ausgabe 2011 - A,X, + 5,Nachrichten-Kopfsegment,,UNH,0051,00003,UN,,UN/CEFACT,X, + 6,Nachrichten-Kopfsegment,,UNH,0057,00003,Versionsnummer derzugrundeliegendenBDEW-Nachrichtenbeschreibung,,S1.1a,X, + 7,Beginn der Nachricht,,BGM,,00004,,,,Muss, + 8,Beginn der Nachricht,,BGM,1001,00004,Z07,,Aktivierung/Deaktivierung vonMaBiS-ZP,X, + 9,Beginn der Nachricht,,BGM,1004,00004,,,Dokumentennummer,X, + 10,Nachrichtendatum,,DTM,,00005,,,,Muss, + 11,Nachrichtendatum,,DTM,2005,00005,137,,Dokumenten-/Nachrichtendatum/-zeit,X, + 12,Nachrichtendatum,,DTM,2380,00005,,,"Datum oder Uhrzeit oderZeitspanne, Wert",X [931][494],"[494] Das hier genannte Datum muss der Zeitpunkt sein, zu dem das Dokument erstellt wurde, oder ein Zeitpunkt, der davor liegt + [931] Format: ZZZ = +00" + 13,Nachrichtendatum,,DTM,2379,00005,303,,CCYYMMDDHHMMZZZ,X, + 14,MP-ID Absender,SG2,,,,,,,Muss, + 15,MP-ID Absender,SG2,NAD,,00008,,,,Muss, + 16,MP-ID Absender,SG2,NAD,3035,00008,MS,,Dokumenten-/Nachrichtenausstellerbzw. -absender,X, + 17,MP-ID Absender,SG2,NAD,3039,00008,,,MP-ID,X, + 18,MP-ID Absender,SG2,NAD,3055,00008,9,,GS1,X, + 19,MP-ID Absender,SG2,NAD,3055,,293,,"DE, BDEW(Bundesverband derEnergie- undWasserwirtschaft e.V.)",X, + 20,Ansprechpartner,SG3,,,,,,,Kann, + 21,Ansprechpartner,SG3,CTA,,00009,,,,Muss, + 22,Ansprechpartner,SG3,CTA,3139,00009,IC,,Informationskontakt,X, + 23,Ansprechpartner,SG3,CTA,3412,00009,,,Name vom Ansprechpartner,X, + 24,Kommunikationsverbindung,SG3,COM,,00010,,,,Muss, + 25,Kommunikationsverbindung,SG3,COM,3148,00010,,,Nummer / Adresse,X (([939][321]) ∨([940][322])) ∧[514],"[321] Wenn im DE3155 in demselben COM der Code EM vorhanden ist + [322] Wenn im DE3155 in demselben COM der Code TE / FX / AJ / AL vorhanden ist + [514] Hinweis: Es darf nur eine Information im DE3148 übermittelt werden + [939] Format: Die Zeichenkette muss die Zeichen @ und . enthalten + [940] Format: Die Zeichenkette muss mit dem Zeichen + beginnen und danach dürfen nur noch Ziffern folgen" + 26,Kommunikationsverbindung,SG3,COM,3155,00010,EM,,Elektronische Post,X [1P0..1], + 27,Kommunikationsverbindung,SG3,COM,3155,,FX,,Telefax,X [1P0..1], + 28,Kommunikationsverbindung,SG3,COM,3155,,TE,,Telefon,X [1P0..1], + 29,Kommunikationsverbindung,SG3,COM,3155,,AJ,,weiteres Telefon,X [1P0..1], + 30,Kommunikationsverbindung,SG3,COM,3155,,AL,,Handy,X [1P0..1], + 31,MP-ID Empfänger,SG2,,,,,,,Muss, + 32,MP-ID Empfänger,SG2,NAD,,00011,,,,Muss, + 33,MP-ID Empfänger,SG2,NAD,3035,00011,MR,,Nachrichtenempfänger,X, + 34,MP-ID Empfänger,SG2,NAD,3039,00011,,,MP-ID,X [280],[280] Nur MP-ID aus Sparte Strom + 35,MP-ID Empfänger,SG2,NAD,3055,00011,9,,GS1,X, + 36,MP-ID Empfänger,SG2,NAD,3055,,293,,"DE, BDEW(Bundesverband derEnergie- undWasserwirtschaft e.V.)",X, + 37,Vorgang,SG4,,,,,,,Muss, + 38,Vorgang,SG4,IDE,,00020,,,,Muss, + 39,Vorgang,SG4,IDE,7495,00020,24,,Transaktion,X, + 40,Vorgang,SG4,IDE,7402,00020,,,Vorgangsnummer,X, + 41,Bilanzierungsende,SG4,DTM,,00030,,,,Muss, + 42,Bilanzierungsende,SG4,DTM,2005,00030,159,,Bilanzierungsende,X, + 43,Bilanzierungsende,SG4,DTM,2380,00030,,,"Datum oder Uhrzeit oderZeitspanne, Wert",X [UB1], + 44,Bilanzierungsende,SG4,DTM,2379,00030,303,,CCYYMMDDHHMMZZZ,X, + 45,Status der Antwort,SG4,STS,,00039,,,,Muss [249],[249] Innerhalb eines SG4 IDE müssen alle DE1131 der SG4 STS+E01 den identischen Wert enthalten + 46,Status der Antwort,SG4,STS,9015,00039,E01,,Status der Antwort,X, + 47,Status der Antwort,SG4,STS,9013,00039,,,Code des Prüfschritts,X, + 48,Status der Antwort,SG4,STS,1131,00039,E_0079,,EBD Nr. E_0079,X, + 49,MaBiS-Zählpunkt,SG5,,,,,,,Muss [2061],[2061] Segment bzw. Segmentgruppe ist genau einmal je SG4 IDE (Vorgang) anzugeben + 50,MaBiS-Zählpunkt,SG5,LOC,,00056,,,,Muss, + 51,MaBiS-Zählpunkt,SG5,LOC,3227,00056,Z15,,MaBiS-Zählpunkt,X, + 52,MaBiS-Zählpunkt,SG5,LOC,3225,00056,,,Identifikator,X [951],[951] Format: Zählpunktbezeichnung + 53,Prüfidentifikator,SG6,,,,,,,Muss, + 54,Prüfidentifikator,SG6,RFF,,00057,,,,Muss, + 55,Prüfidentifikator,SG6,RFF,1153,00057,Z13,,Prüfidentifikator,X, + 56,Prüfidentifikator,SG6,RFF,1154,00057,55212,,Redispatch /Deaktivierung ZPmonatliche AAÜZ,, + 57,Prüfidentifikator,SG6,RFF,1154,,55213,,Redispatch / Antwort aufDeaktivierung ZP,X, + 58,Prüfidentifikator,SG6,RFF,1154,,55214,,Redispatch /WeiterleitungDeaktivierung ZP,, + 59,Referenz Vorgangsnummer (aus Anfragenachricht),SG6,,,,,,,Muss, + 60,Referenz Vorgangsnummer (aus Anfragenachricht),SG6,RFF,,00058,,,,Muss, + 61,Referenz Vorgangsnummer (aus Anfragenachricht),SG6,RFF,1153,00058,TN,,Transaktions-Referenznummer,X, + 62,Referenz Vorgangsnummer (aus Anfragenachricht),SG6,RFF,1154,00058,,,Vorgangsnummer,X, + 63,Nachrichten-Endesegment,,UNT,,00540,,,,Muss, + 64,Nachrichten-Endesegment,,UNT,0074,00540,,,Anzahl der Segmente in einerNachricht,X, + 65,Nachrichten-Endesegment,,UNT,0062,00540,,,Nachrichten-Referenznummer,X, + + ''' +# --- +# name: TestCli.test_kohlrahbi_cli_with_valid_arguments[55555] + ''' + ,Segmentname,Segmentgruppe,Segment,Datenelement,Segment ID,Code,Qualifier,Beschreibung,Bedingungsausdruck,Bedingung + 0,Nachrichten-Kopfsegment,,UNH,,00003,,,,Muss, + 1,Nachrichten-Kopfsegment,,UNH,0062,00003,,,Nachrichten-Referenznummer,X, + 2,Nachrichten-Kopfsegment,,UNH,0065,00003,UTILMD,,Netzanschluss-Stammdaten,X, + 3,Nachrichten-Kopfsegment,,UNH,0052,00003,D,,Entwurfs-Version,X, + 4,Nachrichten-Kopfsegment,,UNH,0054,00003,11A,,Ausgabe 2011 - A,X, + 5,Nachrichten-Kopfsegment,,UNH,0051,00003,UN,,UN/CEFACT,X, + 6,Nachrichten-Kopfsegment,,UNH,0057,00003,Versionsnummer derzugrundeliegendenBDEW-Nachrichtenbeschreibung,,S1.1a,X, + 7,Beginn der Nachricht,,BGM,,00004,,,,Muss, + 8,Beginn der Nachricht,,BGM,1001,00004,Z56,,Änderung individuellerKonfiguration,X, + 9,Beginn der Nachricht,,BGM,1004,00004,,,Dokumentennummer,X, + 10,Nachrichtendatum,,DTM,,00005,,,,Muss, + 11,Nachrichtendatum,,DTM,2005,00005,137,,Dokumenten-/Nachrichtendatum/-zeit,X, + 12,Nachrichtendatum,,DTM,2380,00005,,,"Datum oder Uhrzeit oderZeitspanne, Wert",X [931] [494],"[494] Das hier genannte Datum muss der Zeitpunkt sein, zu dem das Dokument erstellt wurde, oder ein Zeitpunkt, der davor liegt + [931] Format: ZZZ = +00" + 13,Nachrichtendatum,,DTM,2379,00005,303,,CCYYMMDDHHMMZZZ,X, + 14,MP-ID Absender,SG2,,,,,,,Muss, + 15,MP-ID Absender,SG2,NAD,,00008,,,,Muss, + 16,MP-ID Absender,SG2,NAD,3035,00008,MS,,Dokumenten-/Nachrichtenausstellerbzw. -absender,X, + 17,MP-ID Absender,SG2,NAD,3039,00008,,,MP-ID,X, + 18,MP-ID Absender,SG2,NAD,3055,00008,9,,GS1,X, + 19,MP-ID Absender,SG2,NAD,3055,,293,,"DE, BDEW(Bundesverband derEnergie- undWasserwirtschaft e.V.)",X, + 20,Ansprechpartner,SG3,,,,,,,Kann, + 21,Ansprechpartner,SG3,CTA,,00009,,,,Muss, + 22,Ansprechpartner,SG3,CTA,3139,00009,IC,,Informationskontakt,X, + 23,Ansprechpartner,SG3,CTA,3412,00009,,,Name vom Ansprechpartner,X, + 24,Kommunikationsverbindung,SG3,COM,,00010,,,,Muss, + 25,Kommunikationsverbindung,SG3,COM,3148,00010,,,Nummer / Adresse,X (([939] [321])∨ ([940] [322]))∧ [514],"[321] Wenn im DE3155 in demselben COM der Code EM vorhanden ist + [322] Wenn im DE3155 in demselben COM der Code TE / FX / AJ / AL vorhanden ist + [514] Hinweis: Es darf nur eine Information im DE3148 übermittelt werden + [939] Format: Die Zeichenkette muss die Zeichen @ und . enthalten + [940] Format: Die Zeichenkette muss mit dem Zeichen + beginnen und danach dürfen nur noch Ziffern folgen" + 26,Kommunikationsverbindung,SG3,COM,3155,00010,EM,,Elektronische Post,X [1P0..1], + 27,Kommunikationsverbindung,SG3,COM,3155,,FX,,Telefax,X [1P0..1], + 28,Kommunikationsverbindung,SG3,COM,3155,,TE,,Telefon,X [1P0..1], + 29,Kommunikationsverbindung,SG3,COM,3155,,AJ,,weiteres Telefon,X [1P0..1], + 30,Kommunikationsverbindung,SG3,COM,3155,,AL,,Handy,X [1P0..1], + 31,MP-ID Empfänger,SG2,,,,,,,Muss, + 32,MP-ID Empfänger,SG2,NAD,,00011,,,,Muss, + 33,MP-ID Empfänger,SG2,NAD,3035,00011,MR,,Nachrichtenempfänger,X, + 34,MP-ID Empfänger,SG2,NAD,3039,00011,,,MP-ID,X, + 35,MP-ID Empfänger,SG2,NAD,3055,00011,9,,GS1,X, + 36,MP-ID Empfänger,SG2,NAD,3055,,293,,"DE, BDEW(Bundesverband derEnergie- undWasserwirtschaft e.V.)",X, + 37,Vorgang,SG4,,,,,,,Muss, + 38,Vorgang,SG4,IDE,,00020,,,,Muss, + 39,Vorgang,SG4,IDE,7495,00020,24,,Transaktion,X, + 40,Vorgang,SG4,IDE,7402,00020,,,Vorgangsnummer,X, + 41,"Änderung zum, Gültigkeit, Beginndatum",SG4,DTM,,00027,,,,Muss, + 42,"Änderung zum, Gültigkeit, Beginndatum",SG4,DTM,2005,00027,157,,"Gültigkeit, Beginndatum",X, + 43,"Änderung zum, Gültigkeit, Beginndatum",SG4,DTM,2380,00027,,,"Datum oder Uhrzeit oderZeitspanne, Wert",X [UB1], + 44,"Änderung zum, Gültigkeit, Beginndatum",SG4,DTM,2379,00027,303,,CCYYMMDDHHMMZZZ,X, + 45,Transaktionsgrund,SG4,STS,,00037,,,,Muss [2061],[2061] Segment bzw. Segmentgruppe ist genau einmal je SG4 IDE (Vorgang) anzugeben + 46,Transaktionsgrund,SG4,STS,9015,00037,7,,Transaktionsgrund,X, + 47,Transaktionsgrund,SG4,STS,9013,00037,ZT9,,Stammdatenanfrage,X, + 48,Status der Antwort,SG4,STS,,00039,,,,,[249] Innerhalb eines SG4 IDE müssen alle DE1131 der SG4 STS+E01 den identischen Wert enthalten + 49,Status der Antwort,SG4,STS,9015,00039,E01,,Status der Antwort,, + 50,Status der Antwort,SG4,STS,9013,00039,,,Code des Prüfschritts,, + 51,Status der Antwort,SG4,STS,1131,00039,E_0557,,EBD Nr. E_0557,, + 52,Status der Antwort,SG4,STS,1131,,E_0559S_0038,,EBD Nr. E_0559Codeliste Strom Nr.S_0038,,"[4] Wenn MP-ID in SG2 NAD+MR (Nachrichtenempfänger) in der Rolle LF + [233] Wenn MP-ID in SG2 NAD+MR (Nachrichtenempfänger) in der Rolle NB + [241] Wenn MP-ID in SG2 NAD+MR (Nachrichtenempfänger) in der Rolle MSB" + 53,Zieladresse URI,SG4,FTX,,00045,,,,Soll [458],"[4] Wenn MP-ID in SG2 NAD+MR (Nachrichtenempfänger) in der Rolle LF + [233] Wenn MP-ID in SG2 NAD+MR (Nachrichtenempfänger) in der Rolle NB + [453] Wenn bei der Bestellung ein Messprodukt der Codeliste der Konfigurationen aus dem Kapitel 4.4 mit dem Auslöser „Bei Schwellwertunter-/ - überschreitung“ mit selbständiger" + 54,Zieladresse URI,SG4,FTX,4451,00045,Z17,,Zieladresse URI,X, + 55,Zieladresse URI,SG4,FTX,4440,00045,,,Zieladresse URI,X, + 56,Zertifikatsaussteller (Issuer),SG4,FTX,,00046,,,,Soll [458],"[26] Wenn SG4 FTX+Z17 (Zieladresse URI) vorhanden + [458] Wenn bei der Bestellung das Konfigurationsprodukte 9991 00000 073 9 bestellt wurde" + 57,Zertifikatsaussteller (Issuer),SG4,FTX,4451,00046,Z24,,Aussteller (Issuer),X, + 58,Zertifikatsaussteller (Issuer),SG4,FTX,4440,00046,,,Zertifikatsaussteller,X [967],"[967] Format: Zertifikatskörper gemäß X509.1, BSI TR-03109-4" + 59,Zertifikatsnutzer (Subject),SG4,FTX,,00047,,,,Soll [458],"[26] Wenn SG4 FTX+Z17 (Zieladresse URI) vorhanden + [458] Wenn bei der Bestellung das Konfigurationsprodukte 9991 00000 073 9 bestellt wurde" + 60,Zertifikatsnutzer (Subject),SG4,FTX,4451,00047,Z23,,Zertifikatsnutzer(Subject),X, + 61,Zertifikatsnutzer (Subject),SG4,FTX,4440,00047,,,Zertifikatsnutzer,X [967],"[967] Format: Zertifikatskörper gemäß X509.1, BSI TR-03109-4" + 62,IP-Adresse für das CLS- Device,SG4,FTX,,00048,,,,Soll [459],[4] Wenn MP-ID in SG2 NAD+MR (Nachrichtenempfänger) in + 63,IP-Adresse für das CLS- Device,SG4,FTX,4451,00048,Z18,,IP-Adresse für das CLS-Device,X, + 64,IP-Adresse für das CLS- Device,SG4,FTX,4440,00048,,,Freier Text,X, + 65,Prüfidentifikator,SG6,,,,,,,Muss, + 66,Prüfidentifikator,SG6,RFF,,00057,,,,Muss, + 67,Prüfidentifikator,SG6,RFF,1153,00057,Z13,,Prüfidentifikator,X, + 68,Prüfidentifikator,SG6,RFF,1154,00057,55555,,GPKE / AnfrageStammdaten aufindividuelle Bestellung,X, + 69,Prüfidentifikator,SG6,RFF,1154,,55556,,GPKE / Antwort aufAnfrage der individuellenBestellung,, + 70,Referenz Vorgangsnummer (aus Anfragenachricht),SG6,,,,,,,, + 71,Referenz Vorgangsnummer (aus Anfragenachricht),SG6,RFF,,00058,,,,, + 72,Referenz Vorgangsnummer (aus Anfragenachricht),SG6,RFF,1153,00058,TN,,Transaktions-Referenznummer,, + 73,Referenz Vorgangsnummer (aus Anfragenachricht),SG6,RFF,1154,00058,,,Vorgangsnummer,, + 74,Referenznummer der Nachricht der betroffenen Antwort auf Bestellung ,SG6,,,,,,,Muss, + 75,Referenznummer der Nachricht der betroffenen Antwort auf Bestellung ,SG6,RFF,,00061,,,,Muss, + 76,Referenznummer der Nachricht der betroffenen Antwort auf Bestellung ,SG6,RFF,1153,00061,Z42,,Referenznummer derNachricht derbetroffenen Antwort aufBestellung(Bestellbestätigung),X, + 77,Referenznummer der Nachricht der betroffenen Antwort auf Bestellung ,SG6,RFF,1154,00061,,,"Referenz, Identifikation",X, + 78,Referenznummer des Vorgangs der betroffenen Antwort auf Bestellung,SG6,,,,,,,Muss, + 79,Referenznummer des Vorgangs der betroffenen Antwort auf Bestellung,SG6,RFF,,00062,,,,Muss, + 80,Referenznummer des Vorgangs der betroffenen Antwort auf Bestellung,SG6,RFF,1153,00062,Z43,,Referenznummer desVorgangs derbetroffenen Antwort aufBestellung(Bestellbestätigung),X, + 81,Referenznummer des Vorgangs der betroffenen Antwort auf Bestellung,SG6,RFF,1154,00062,,,"Referenz, Identifikation",X, + 82,OBIS-Daten der Marktlokation,SG8,,,,,,,Soll [457],"[4] Wenn MP-ID in SG2 NAD+MR (Nachrichtenempfänger) in der Rolle LF + [457] Wenn bei der Bestellung das Messprodukten 9991 00000 149 8 bestellt wurde" + 83,OBIS-Daten der Marktlokation,SG8,SEQ,,00198,,,,Muss, + 84,OBIS-Daten der Marktlokation,SG8,SEQ,1229,00198,Z02,,OBIS-Daten derMarktlokation,Muss, + 85,Referenz auf die ID der Marktlokation,SG8,RFF,,00199,,,,Muss, + 86,Referenz auf die ID der Marktlokation,SG8,RFF,1153,00199,Z18,,Marktlokation,X, + 87,Referenz auf die ID der Marktlokation,SG8,RFF,1154,00199,,,ID einer Marktlokation,X [950],[950] Format: Marktlokations-ID + 88,OBIS-Kennzahl der Marktlokation,SG8,PIA,,00200,,,,Muss, + 89,OBIS-Kennzahl der Marktlokation,SG8,PIA,4347,00200,5,,Produktidentifikation,X, + 90,OBIS-Kennzahl der Marktlokation,SG8,PIA,7140,00200,,,OBIS-Kennzahl der Marktlokation,X, + 91,OBIS-Kennzahl der Marktlokation,SG8,PIA,7143,00200,SRW,,OBIS-Kennzahl,X, + 92,Wertegranularität,SG10,,,,,,,Muss [257],[257] Wenn in derselben SG8 SEQ+Z02 (OBIS-Daten der Marktlokation) das PIA+5+1- b?:1.9.e vorhanden + 93,Wertegranularität,SG10,CCI,,00201,,,,Muss, + 94,Wertegranularität,SG10,CCI,7037,00201,ZE4,,Wertegranularität,X, + 95,Wertegranularität,SG10,CAV,,00202,,,,Muss, + 96,Wertegranularität,SG10,CAV,7111,00202,ZD9,,Jährlich,X, + 97,Wertegranularität,SG10,CAV,7111,,ZE8,,Halbjährlich,X, + 98,Wertegranularität,SG10,CAV,7111,,ZE9,,Quartalsweise,X, + 99,Wertegranularität,SG10,CAV,7111,,ZB7,,Monatlich,X, + 100,Zugeordnete Zählzeitdefinition,SG10,,,,,,,Soll [166],[166] Wenn vorhanden + 101,Zugeordnete Zählzeitdefinition,SG10,CCI,,00203,,,,Muss, + 102,Zugeordnete Zählzeitdefinition,SG10,CCI,7059,00203,Z39,,Code derZählzeitdefinition,X, + 103,Zugeordnete Zählzeitdefinition,SG10,CCI,7037,00203,,,Code der Zählzeitdefinition,X, + 104,Zugeordnetes Zählzeitregister ,SG10,,,,,,,Muss [421],[421] Wenn in dieser SG8 das SG10 CCI+Z39 (Zugeordnete Zählzeitdefinition) vorhanden ist + 105,Zugeordnetes Zählzeitregister ,SG10,CCI,,00204,,,,Muss, + 106,Zugeordnetes Zählzeitregister ,SG10,CCI,7059,00204,Z38,,Code desZählzeitregisters,X, + 107,Zugeordnetes Zählzeitregister ,SG10,CCI,7037,00204,,,Code des Zählzeitregisters,X, + 108,Zähleinrichtungsdaten,SG8,,,,,,,Soll [457],[457] Wenn bei der Bestellung das Messprodukten 9991 00000 149 8 bestellt wurde + 109,Zähleinrichtungsdaten,SG8,SEQ,,00326,,,,Muss, + 110,Zähleinrichtungsdaten,SG8,SEQ,1229,00326,Z03,,Zähleinrichtungsdaten,X, + 111,Referenz auf die ID einer Messlokation,SG8,RFF,,00327,,,,Muss, + 112,Referenz auf die ID einer Messlokation,SG8,RFF,1153,00327,Z19,,Messlokation,X, + 113,Referenz auf die ID einer Messlokation,SG8,RFF,1154,00327,,,ID einer Messlokation,X [951],[951] Format: Zählpunktbezeichnung + 114,Referenz auf das Smartmeter-Gateway,SG8,RFF,,00328,,,,Muss, + 115,Referenz auf das Smartmeter-Gateway,SG8,RFF,1153,00328,Z14,,Smartmeter-Gateway,X, + 116,Referenz auf das Smartmeter-Gateway,SG8,RFF,1154,00328,,,Identifikation / Nummer desSmartmeter-Gateways,X, + 117,Zählertyp,SG10,,,,,,,Muss, + 118,Zählertyp,SG10,CCI,,00329,,,,Muss, + 119,Zählertyp,SG10,CCI,7037,00329,E13,,Zählertyp,X, + 120,Identifikation / Nummer des Gerätes,SG10,CAV,,00331,,,,Muss, + 121,Identifikation / Nummer des Gerätes,SG10,CAV,7111,00331,Z30,,Gerätenummer,X, + 122,Identifikation / Nummer des Gerätes,SG10,CAV,7110,00331,,,Gerätenummer,X, + 123,OBIS-Daten der Zähleinrichtung / Smartmeter-Gateway,SG8,,,,,,,Soll [166],"[4] Wenn MP-ID in SG2 NAD+MR (Nachrichtenempfänger) in der Rolle LF + [166] Wenn vorhanden + [233] Wenn MP-ID in SG2 NAD+MR (Nachrichtenempfänger) in der Rolle NB + [241] Wenn MP-ID in SG2 NAD+MR (Nachrichtenempfänger) in der Rolle MSB + [457] Wenn bei der Bestellung das Messprodukten 9991 00000 149 8 bestellt wurde + [460] Wenn bei der Bestellung ein Messprodukt der Codeliste der Konfigurationen aus dem Kapitel 4.4 mit dem Übertragungsweg ""aus dem SMGW"" bestellt wurde" + 124,OBIS-Daten der Zähleinrichtung / Smartmeter-Gateway,SG8,SEQ,,00339,,,,Muss, + 125,OBIS-Daten der Zähleinrichtung / Smartmeter-Gateway,SG8,SEQ,1229,00339,Z20,,OBIS-Daten derZähleinrichtung,X, + 126,Referenz auf die Gerätenummer,SG8,RFF,,00340,,,,Muss [665],[665] Hinweis: Wenn ein Zähler mit einem SMGW parametriert ist werden an dem Zähler keine OBIS- Kennzahlen angegeben Hier gibt es nur OBIS Kennzahlen vom SMGW + 127,Referenz auf die Gerätenummer,SG8,RFF,1153,00340,Z14,,Smartmeter-Gateway,X, + 128,Referenz auf die Gerätenummer,SG8,RFF,1154,00340,,,Gerätenummer,X [952],[952] Format: Gerätenummer nach DIN 43863-5 + 129,Referenz auf die ID einer Messlokation,SG8,RFF,,00341,,,,Muss, + 130,Referenz auf die ID einer Messlokation,SG8,RFF,1153,00341,Z19,,Messlokation,X, + 131,Referenz auf die ID einer Messlokation,SG8,RFF,1154,00341,,,ID einer Messlokation,X [951],[951] Format: Zählpunktbezeichnung + 132,Konfigurations-ID,SG8,RFF,,00343,,,,Muss, + 133,Konfigurations-ID,SG8,RFF,1153,00343,AGK,,Anwendungsreferenznummer,X, + 134,Konfigurations-ID,SG8,RFF,1154,00343,,,"Referenz, Identifikation",X, + 135,OBIS-Kennzahl der Zähleinrichtung / Smartmeter-Gateway,SG8,PIA,,00344,,,,Muss, + 136,OBIS-Kennzahl der Zähleinrichtung / Smartmeter-Gateway,SG8,PIA,4347,00344,5,,Produktidentifikation,X, + 137,OBIS-Kennzahl der Zähleinrichtung / Smartmeter-Gateway,SG8,PIA,7140,00344,,,OBIS-Kennzahl derZähleinrichtung,X, + 138,OBIS-Kennzahl der Zähleinrichtung / Smartmeter-Gateway,SG8,PIA,7143,00344,SRW,,OBIS-Kennzahl,X, + 139,Wertegranularität,SG10,,,,,,,Muss [256],[256] Wenn in derselben SG8 SEQ+Z20 (OBIS-Daten der Zähleinrichtung / Smartmeter-Gateway) das PIA+5+1-b?:1.8.e / 1-b?:2.8.e vorhanden + 140,Wertegranularität,SG10,CCI,,00345,,,,Muss, + 141,Wertegranularität,SG10,CCI,7037,00345,ZE4,,Wertegranularität,X, + 142,Wertegranularität,SG10,CAV,,00346,,,,Muss, + 143,Wertegranularität,SG10,CAV,7111,00346,ZD9,,Jährlich,X, + 144,Wertegranularität,SG10,CAV,7111,,ZE8,,Halbjährlich,X, + 145,Wertegranularität,SG10,CAV,7111,,ZE9,,Quartalsweise,X, + 146,Wertegranularität,SG10,CAV,7111,,ZB7,,Monatlich,X, + 147,Zugeordnete Zählzeitdefinition,SG10,,,,,,,Soll [166],[166] Wenn vorhanden + 148,Zugeordnete Zählzeitdefinition,SG10,CCI,,00347,,,,Muss, + 149,Zugeordnete Zählzeitdefinition,SG10,CCI,7059,00347,Z39,,Code derZählzeitdefinition,X, + 150,Zugeordnete Zählzeitdefinition,SG10,CCI,7037,00347,,,Code der Zählzeitdefinition,X, + 151,Zugeordnetes Zählzeitregister ,SG10,,,,,,,Muss [421],[421] Wenn in dieser SG8 das SG10 CCI+Z39 (Zugeordnete Zählzeitdefinition) vorhanden ist + 152,Zugeordnetes Zählzeitregister ,SG10,CCI,,00348,,,,Muss, + 153,Zugeordnetes Zählzeitregister ,SG10,CCI,7059,00348,Z38,,Code desZählzeitregisters,X, + 154,Zugeordnetes Zählzeitregister ,SG10,CCI,7037,00348,,,Code des Zählzeitregisters,X, + 155,Vor- und Nachkommastellen des Zählwerks,SG10,,,,,,,Muss, + 156,Vor- und Nachkommastellen des Zählwerks,SG10,CCI,,00349,,,,Muss, + 157,Vor- und Nachkommastellen des Zählwerks,SG10,CCI,7059,00349,11,,Produkt,X, + 158,Vor- und Nachkommastellen des Zählwerks,SG10,CCI,7037,00349,Z33,,Vor- undNachkommastellen desZählwerkes,X, + 159,Vor- und Nachkommastellen des Zählwerks,SG10,CAV,,00350,,,,Muss, + 160,Vor- und Nachkommastellen des Zählwerks,SG10,CAV,7110,00350,,,Angabe der Vorkommastelle,X, + 161,Vor- und Nachkommastellen des Zählwerks,SG10,CAV,7110,00350,,,Angabe der Nachkommastelle,X, + 162,Bezeichnung des Zählwerks auf dem Gerät,SG10,,,,,,,Muss, + 163,Bezeichnung des Zählwerks auf dem Gerät,SG10,CCI,,00351,,,,Muss, + 164,Bezeichnung des Zählwerks auf dem Gerät,SG10,CCI,7037,00351,Z63,,Lokale Kennzeichnung zuKontrollzwecken,X, + 165,Bezeichnung des Zählwerks auf dem Gerät,SG10,CCI,7036,00351,,,Bezeichnung des Zählwerks aufdem Gerät,X, + 166,Nachrichten-Endesegment,,UNT,,00540,,,,Muss, + 167,Nachrichten-Endesegment,,UNT,0074,00540,,,Anzahl der Segmente in einerNachricht,X, + 168,Nachrichten-Endesegment,,UNT,0062,00540,,,Nachrichten-Referenznummer,X, + + ''' # --- diff --git a/unittests/test_ahb.py b/unittests/test_ahb.py index 8442c313..b03edf4c 100644 --- a/unittests/test_ahb.py +++ b/unittests/test_ahb.py @@ -12,45 +12,14 @@ from unittests import path_to_test_edi_energy_mirror_repo, path_to_test_files_fv2310 +@pytest.mark.snapshot class TestAhb: - def test_extract_pruefis_from_docx(self) -> None: - """ - extract_pruefis_from_docx. - """ - input_path = path_to_test_files_fv2310 / Path( - "COMDISAHB-informatorischeLesefassung1.0dKonsolidierteLesefassungmitFehlerkorrekturenStand19.06.2023_20230719_20231001.docx" - ) - pruefis = extract_pruefis_from_docx(input_path) - assert ( - "29001" in pruefis - and pruefis["29001"] - == "COMDISAHB-informatorischeLesefassung1.0dKonsolidierteLesefassungmitFehlerkorrekturenStand19.06.2023_20230719_20231001.docx" - ) - assert ( - "29002" in pruefis - and pruefis["29002"] - == "COMDISAHB-informatorischeLesefassung1.0dKonsolidierteLesefassungmitFehlerkorrekturenStand19.06.2023_20230719_20231001.docx" - ) - - def test_find_pruefidentifikatoren(self): + def test_find_pruefidentifikatoren(self, snapshot): """ test find_pruefidentifikatoren. """ - pruefis = find_pruefidentifikatoren(path_to_test_files_fv2310) - assert ( - "29001" in pruefis - and pruefis["29001"] - == "COMDISAHB-informatorischeLesefassung1.0dKonsolidierteLesefassungmitFehlerkorrekturenStand19.06.2023_20230719_20231001.docx" - ) - assert ( - "17201" in pruefis - and pruefis["17201"] == "ORDERSORDRSPAHBMaBiS-informatorischeLesefassung2.2c_99991231_20231001.docx" - ) - assert ( - "37001" in pruefis - and pruefis["37001"] - == "PARTINAHB-informatorischeLesefassung1.0cKonsolidierteLesefassungmitFehlerkorrekturenStand29.09.2023_20240402_20231001.docx" - ) + pruefis = find_pruefidentifikatoren(Path(__file__).parents[1] / "edi_energy_mirror/edi_energy_de/FV2310") + assert pruefis == snapshot def test_get_ahb_documents_path(self): """ diff --git a/unittests/test_current_state.py b/unittests/test_current_state.py index 9faff87f..e905af69 100644 --- a/unittests/test_current_state.py +++ b/unittests/test_current_state.py @@ -10,7 +10,7 @@ from click.testing import CliRunner, Result from kohlrahbi import cli -from unittests import path_to_test_edi_energy_mirror_repo, path_to_test_files_fv2310 +from unittests import current_state_pruefis # Setup basic configuration for logging logging.basicConfig(level=logging.INFO, format="%(asctime)s - %(levelname)s - %(message)s") @@ -25,6 +25,7 @@ def get_csv_paths(root_dir) -> list[Path]: return [path for path in root_path.rglob("*.csv")] +@pytest.mark.snapshot class TestCli: """ This class contains the unit tests for the CLI tool. @@ -36,29 +37,32 @@ class TestCli: pytest.param( [ "ahb", + "--assume-yes", "--format-version", - "FV2310", + "FV2404", "--file-type", "csv", + "-p", + pruefi, ], {"exit_code": 0, "output_snippet": ""}, - id="proof of concept", + id=pruefi, ) + for pruefi in current_state_pruefis ], ) def test_kohlrahbi_cli_with_valid_arguments( - self, argument_options: list[str], expected_response: dict[str, Union[str, int]], snapshot + self, argument_options: list[str], expected_response: dict[str, Union[str, int]], snapshot, tmp_path ): """ This test runs the CLI tool with valid arguments and checks if the output is as expected. """ - - actual_output_dir = path_to_test_files_fv2310 / "actual-output" + actual_output_dir = tmp_path / "actual-output" argument_options.extend( [ "--edi-energy-mirror-path", - str(path_to_test_edi_energy_mirror_repo), + str(Path(__file__).parents[1] / "edi_energy_mirror"), "--output-path", str(actual_output_dir), ] @@ -76,10 +80,7 @@ def test_kohlrahbi_cli_with_valid_arguments( # Check if the generated files are the same as the expected files - path_to_actual_csv_files = get_csv_paths(actual_output_dir) + path_to_actual_csv_file = get_csv_paths(actual_output_dir) - actual_csv_dict: dict[str, str] = {} - for file in path_to_actual_csv_files: - with open(file, "r", encoding="utf-8") as actual_csv: - actual_csv_dict[file.name] = actual_csv.read() - assert snapshot == actual_csv_dict + with open(path_to_actual_csv_file[0], "r", encoding="utf-8") as actual_csv: + assert snapshot == actual_csv.read()