diff --git a/EasyEplanner.Tests/EplanDevice.Test/IODevice.Test/C.Test.cs b/EasyEplanner.Tests/EplanDevice.Test/IODevice.Test/C.Test.cs
index 24f37f7c..530856fb 100644
--- a/EasyEplanner.Tests/EplanDevice.Test/IODevice.Test/C.Test.cs
+++ b/EasyEplanner.Tests/EplanDevice.Test/IODevice.Test/C.Test.cs
@@ -146,10 +146,7 @@ private static object[] ParametersTestData()
var paramters_THLD = new string[]
{
IODevice.Parameter.P_is_reverse,
- IODevice.Parameter.P_DELTA,
- IODevice.Parameter.P_ON_TIME,
- IODevice.Parameter.P_OFF_TIME,
-
+ IODevice.Parameter.P_delta,
};
var defaultValues = new double[]
@@ -183,7 +180,7 @@ private static object[] ParametersTestData()
new object[]
{
paramters_THLD,
- new double[]{ 0, 0, 0, 0, },
+ new double[]{ 0, 0, },
C_THLD,
GetNewCDevice(),
},
diff --git a/docs/user_manual/ReadMe.md b/docs/user_manual/ReadMe.md
index 7786c175..41e407ed 100644
--- a/docs/user_manual/ReadMe.md
+++ b/docs/user_manual/ReadMe.md
@@ -1043,9 +1043,7 @@ C_THLD | Пороговый регулятор.
C_THLD (пороговый регулятор)
| P_is_reverse | Выход обратного действия (1 - true, 0 - false). Задает вектор изменения измеряемой величины. |
- P_DELTA | Дельта срабатывания, % |
- P_ON_TIME | Задержка включения, мс |
- P_OFF_TIME | Задержка выключения, мс
+ | P_delta | Дельта срабатывания, % |
CAM
| P_READY_TIME | Предельное время отсутствия готовности к работе, с (для CAM_DO1_DI2 и CAM_DO1_DI3)
diff --git a/src/Device/IODevices/C.cs b/src/Device/IODevices/C.cs
index ef5b13d5..30a15bd6 100644
--- a/src/Device/IODevices/C.cs
+++ b/src/Device/IODevices/C.cs
@@ -79,10 +79,7 @@ public override string SetSubType(string subType)
properties.Add(Property.OUT_VALUE, null);
parameters.Add(Parameter.P_is_reverse, null);
- parameters.Add(Parameter.P_DELTA, null);
- parameters.Add(Parameter.P_ON_TIME, null);
- parameters.Add(Parameter.P_OFF_TIME, null);
-
+ parameters.Add(Parameter.P_delta, null);
break;
default:
diff --git a/src/Device/Parameter.cs b/src/Device/Parameter.cs
index 168cc64d..f3efd107 100644
--- a/src/Device/Parameter.cs
+++ b/src/Device/Parameter.cs
@@ -136,7 +136,7 @@ public class Parameter
public static readonly Parameter P_ERR_MIN_FLOW = new Parameter("P_ERR_MIN_FLOW", "Ошибка счета импульсов");
/// Дельта значение
- public static readonly Parameter P_DELTA = new Parameter(nameof(P_DELTA), "Дельта срабатывания");
+ public static readonly Parameter P_delta = new Parameter(nameof(P_delta), "Дельта срабатывания");
protected static readonly Lazy> AllParameters = InitParameters();
@@ -211,7 +211,7 @@ public static string GetFormatValue(Parameter parameter, object value, IODevice
return string.Format(UnitFormat.Kilograms, displayedValue);
break;
case DeviceType.C:
- if (parameter == P_max || parameter == P_min || parameter == P_DELTA)
+ if (parameter == P_max || parameter == P_min || parameter == P_delta)
{
var inValue = device.Properties[Property.IN_VALUE];
|