Notifications
You must be signed in to change notification settings - Fork 54
McStas and Mantid
- Introduction
- Background and Motivation
- The NeXus data format
- McStas Mantid workflow
- Setup the McStas instrument to create a Mantid instrument
- McStas GUI
- McStas CLI
- MantidPlot view of McStas event data
- Mantid reduction of McStas event data
- ISIS SANS2D
- Install NeXus
- References Label
The McStas-Mantid data interface can be used to load McStas event data into Mantid, from whereon further data reduction and analysis can be performed. The purpose of this page is to demonstrate the methodologies, techniques and workflows used when combining McStas and Mantid.
To demonstrate this we use the templateSANS_Mantid.instr file, which is distributed along with McStas in the neutron suite of instrument files. As a second example, we show how to apply the McStas–Mantid interface to the ISIS SANS2D beamline.
For the first description of the McStas-Mantid data interface see [1]. This wiki aims to provide up-to-date information on how to use this interface.
The McStas neutron ray-tracing simulation package is a versatile tool for producing accurate simulations of neutron scattering instruments at reactors and pulsed spallation sources [2, 3, 5]. McStas is extensively used for the design and optimization of instruments, virtual experiments, and user training. McStas is an abbreviation for Monte Carlo Simulation of triple axis spectrometers, but allows for describing and simulating any types of neutron scattering instrument.
The Mantid project provides a framework that supports high-performance computing and visualisation of scientific data [4, 6]. The Mantid framework is a software solution developed for the analysis and visualization of neutron scattering and muon spin measurements. Mantid is an abbreviation for Manipulation and Analysis Toolkit for Instrument Data.
By combining both the McStas neutron transport and the Mantid reduction framework a complete simulation of a neutron scattering experiment can be achieved; where neutron transport and data reduction can be done in one go.
A number of large-scale neutron facilities uses the NeXus data format [7] for storing neutron data. NeXus is derived from the Hierarchical Data Format (HDF) [8]. The specific detail of how the neutron counts and metadata are stored in the NeXus files changes from beam line to beam line. However, the NeXus application programming interface (API) is supported on multiple platforms and has library support for multiple programming languages [7]. McStas can write NeXus files and Mantid can read and write NeXus data files.
To use the McStas-Mantid interface the libraries for the NeXus data format must be installed on your computer. See section Install NeXus for how to install NeXus.
Generating McStas event data for Mantid is slightly different from running a standard McStas simulation. It requires the following procedure:
- Generate the instrument file for Mantid, from the McStas instrument file.
- Compile the McStas c code. Remember to link correctly to NeXus libraries.
- Run McStas simulation with the NeXus flag "on" to produce event data for Mantid.
Step 1 will generate an xml file for Mantid with a description of the instrument geometry known as the Instrument Definition File (IDF). The IDF is used for time-of-flight (TOF) conversions in Mantid. Importantly, the IDF requires a unique Detector ID for each detector pixel, which are used to link neutron events with detector pixels. Step 2 is used to make sure your McStas simulation can produce a NeXus file as output. Step 3 is used to run the McStas simulation and ask for a NeXus file as output of the simulation, as opposed to several ascii files, which is the default setup in McStas.
The McStas graphical user interface (GUI) is named mcgui
. Below we show how to configure mcgui
such that McStas event data for Mantid can easily be performed from the McStas GUI. Step 2 and 3 depend on your computers operating system (OS), as we show below.
Figure 0: McStas Mantid workflow.
For McStas to autogenerate a Mantid IDF the McStas instrument file must obey:
- McStas instrument file name and the McStas defined name of the instrument must be the same
- E.g.
templateSANS_Mantid.instr
andDEFINE INSTRUMENT templateSANS_Mantid(…)
- E.g.
- In the McStas instrument file the source must be named “sourceMantid”
- E.g.
COMPONENT sourceMantid = Source_simple(…)
- E.g.
- In the McStas instrument file the sample must be named “sampleMantid”
- E.g.
COMPONENT sampleMantid = Sans_spheres(…)
- E.g.
- In the McStas instrument file the event monitors must be named “nD_Mantid_#”
- E.g.
COMPONENT nD_Mantid_1 = Monitor_nD(…)
for the first event detector bank - E.g.
COMPONENT nD_Mantid_2 = Monitor_nD(…)
for the second event detector bank
- E.g.
To use a square shaped monitor_nD the COMPONENT nD_Mantid_1 must be called with the argument: options ="mantid square x limits=[-0.2] bins=128 y limits=[-0.2] bins=128, neutron pixel min=0 t, list all neutrons". The number of bins and limits can be chosen freely, but "list all neutrons" is required. 'min=0' specifies the detector IDs required for Mantid, where 'min=0' means that the first detector ID will be 0 the next 1 and so on. Each detector pixel in Mantid must have associated with it a unique detector ID. Hence if you if have a mcstas instrument with several detector banks then you much ensure that these are unique. However these numbers don't have to be in increments of one.
For a simple example of an instrument with one bank see: templateSANS_Mantid.instr.
For a simple example of an instrument setup to study multiple scattering see: templateVanadiumMultipleScat_Mantid.instr. Multiple scattering is a special case since exactly the same Mcstas detector components are specified more than once in the McStas instrument file. In the simple example this is:
%{
if (SCATTERED == 1) single_flag =1 ;
if (SCATTERED > 1) multi_flag =1 ;
%}
COMPONENT nD_Mantid_0 = Monitor_nD(
options ="Mantid square, x limits=[-2.5 2.5] bins=50 y limits=[-2.5 2.5] bins=50, neutron pixel min=0 t limits [0.002,0.005] list all neutrons, file=multi",
xwidth = 5, yheight = 5, restore_neutron = 1)
WHEN (multi_flag ==1)
AT (0, 0, 1) RELATIVE sampleMantid
COMPONENT Mantid_1 = Monitor_nD(
options ="square, x limits=[-2.5 2.5] bins=50 y limits=[-2.5 2.5] bins=50, neutron pixel min=0 t limits [0.002,0.005] list all neutrons, file=single",
xwidth = 5, yheight = 5, restore_neutron = 1)
WHEN (single_flag ==1)
AT (0, 0, 1) RELATIVE sampleMantid
As is seen above exactly the same component is specified twice with particles recorded in file=multi and file=single respectively. To avoid that a Mantid instrument is created with two identical components sitting on top of each other, the Mantid key-words are only used for the first component. That way only this first component is added to the Mantid IDF and Mantid will use this IDF to create workspaces for both file=multi and file=single.
A banana shaped monitor can be added as follows: nD_Mantid_1 = Monitor_nD(xwidth=2*radius, yheight=0.8, options="mantid banana, theta limits=[-173 173] bins=100, y limits=[-0.4 0.4] bins=100, neutron pixel min=0 t, list all neutrons"). A full example of how to such a component can be specified is:
COMPONENT nD_Mantid_1 = Monitor_nD(
xwidth=sampdet, yheight=0.1,
options="mantid banana, theta limits=[0 27] bins=256, y bins=1, neutron pixel min=0 t, list all neutrons",
filename = "bank01_events.dat")
AT(0.0, 0.0, 0.0) RELATIVE PREVIOUS
McStas also supports event monitors defined by OFF geometry files. Contact the McStas developers on how to use OFF detectors at [email protected].
Generating McStas event data for Mantid can be achieved from the McStas GUI mcgui
. Below we show how to setup the simulation on Windows 7, OSX 10.12, and Ubuntu 16.04. For McStas we use version 2.4.1. For Mantid use version 3.4 or later.
- Open the McStas configuration file. In
mcgui
go to: File -> Configuration - Change the setting as shown in figures below:
- In the section
mcrun
selectmcrun --format=NeXus
- In the section
mcplot
selectmcplot-pyqtgraph
- In the section
mcdisplay
selectmcdisplay-pl --format=Mantid
(Windows) ormcdisplay.pl --format=Mantid
(OSX or Ubuntu) - In the section
C flags
select this line depending on your OS- Windows:
-g -O2 -lm -DUSE_NEXUS -llibNeXus-0 -I "C:/Program Files (x86)/NeXus Data Format/include/nexus" -L "C:/Program Files (x86)/NeXus Data Format/lib/nexus"
- OS X:
-g -O2 -lm -DUSE_NEXUS -lNeXus -I/usr/local/include/nexus
- Ubuntu:
-g -O2 -lm -DUSE_NEXUS -lNeXus
- Windows:
- In the section
Figure 1: McStas GUI configuration widget. Windows 7 (top left), OS X 10.12 (top right), Ubuntu 16.04 (bottom).
In Fig. 1 the mcgui
configuration widgets for Windows, Mac OS X, and Ubuntu are shown. Press Save
to keep the configuration settings.
You should check your local installation if the above mentioned paths to libraries and header files are equal – otherwise modify accordingly to your laptop settings.
- Load instrument file:
- Download and use the latest version of templateSANS_Mantid.inst. Select
Open
and choose the downloaded instrument file.
- Download and use the latest version of templateSANS_Mantid.inst. Select
- Compile the instrument file: Simulation -> Compile Instrument
- Generate the IDF: Press
Run
inmcgui
:- In the section
Simulation/Trace
chooseTrace
- In the section
Particle count
type1
- Run simulation: Press
Start
- In the section
Figure 2: McStas GUI for generating the IDF xml file for Mantid.
A new file is written to disk: templateSANS_Mantid.instr.xml
- Run the McStas simulation: Press
Run
inmcgui
:- In the section
Simulation/Trace:
chooseSimulation
- In the section
Particle count:
type1E8
- In the section
Output subdir(optional):
type1E8
- Run simulation: Press
Start
- In the section
Figure 3: McStas GUI run widget (top). McStas GUI simulation started (bottom).
A new folder is written to disk 1E8
with two files: mccode.h5
and templateSANS_Mantid.instr
. Notice: NeXus files cannot be plotted from McStas.
Generating McStas event data for Mantid can also be controlled from the terminal, using this command line interface (CLI). Below we show how to setup the simulation for OSX 10.12 and Ubuntu 14.04. The procedure for Windows is similar. For McStas we use version 2.4.1.
- Compile McStas instrument file
$ mcstas templateSANS_Mantid.instr --trace
- Generate the IDF for Mantid
$ mcdisplay.pl templateSANS_Mantid.instr --format=Mantid -n0
- Generate the executable for Mac OS X
$ gcc -o templateSANS_Mantid.out templateSANS_Mantid.c -lm -DUSE_NEXUS -lNeXus -I/usr/local/include/nexus/
And for Ubuntu
$ gcc -o templateSANS_Mantid.out templateSANS_Mantid.c -lm -DUSE_NEXUS -lNeXus
- Run the executable and use the default parameters
$ ./templateSANS_Mantid.out --format=NeXus -d 1E8
- Compile McStas instrument file
C:\Users\jsmith mcstas templateSANS_Mantid.instr --trace
- Generate the IDF for Mantid
C:\Users\jsmith mcdisplay-pl templateSANS_Mantid.instr --format=Mantid -n0
- Generate the executable for Windows
c:\Users\jsmith gcc.exe -o templateSANS_Mantid.exe templateSANS_Mantid.c -lm -DUSE_NEXUS -llibNeXus-0 -L "C:\Program Files\NeXus Data Format\lib\nexus" -I "C:\Program Files\NeXus Data Format\include\nexus"
- Run the executable for Windows
c:\Users\jsmith templateSANS_Mantid.exe --format=NeXus -d 01
- Generate the MPI executable for Windows
gcc.exe -o templateSANS_Mantid.exe templateSANS_Mantid.c -g -O2 -lm -DUSE_MPI -DUSE_NEXUS -llibNeXus-0 -L "C:\Program Files\NeXus Data Format\lib\nexus" -I "C:\Program Files\NeXus Data Format\include\nexus" -lmsmpi -I"C:\Program Files (x86)\Microsoft SDKs\MPI\Include" -L"C:\Program Files (x86)\Microsoft SDKs\MPI\Lib\x64"
- Run the executable for Windows - method 1
c:\Users\jsmith mpiexec -np 2 templateSANS_Mantid.exe --format=NeXus -d 01_MPI
- Run the executable for Windows - method 2
c:\Users\jsmith mcrun templateSANS_Mantid.exe --mpi=2 --format=NeXus -d 02_MPI
Below we show how the simulated data from templateSANS_Mantid.instr can be viewed in Mantid by just using the Mantid GUI. Use Mantid version 3.4 or later.
- Open MantidPlot
- Press
load
and select the just created Mcstas file mccode.h5 (created following the above procedure)
Figure 4 shows a typical view of McStas data in Mantid. Use the following steps:
- In
Workspaces
left-click on the McStas datamccode
- Right-click on
EventData_mccode
chooseShow Instrument
- Zoom in/out and rotate to find the detector
- Right-click on
Edet0.dat_mccode
choosePlot Spectrum
. (Use log scale for y-axis.) - Right-click on
PSD.dat_mccode
chooseColor fill plot
. (Use log scale for colour plot.)
Figure 4: Mantidplot used to display event and histogram data stored in the McStas file mccode.h5
Once McStas event data has been loaded into Mantid, all of Mantid analysis methods can be applied to the dataset. This makes already developed and tested methods from Mantid directly applicable to McStas data, and will in turn make the analysis faster as the users do not have to reinvent and re-implement reduction and analysis methods.
To show how the reduction methodology works in Mantid we shall consider the McStas event data set generated with the templateSANS_Mantid.instr file. The goal of this small exercise is to compare the reduced scattering curve evaluated by Mantid to the scattering kernel used in the McStas sample component. By a proper set of operations on the original McStas event data [1], Mantid can eventually return the scattering curve I(q) for the data recorded on the detector, and hence the scattering cross section of the sample can be deduced; including sample specific parameters.
Use the steps and python script listed below in Mantid to evaluate I(q):
- In the
Script Interpreter
window (i.e. the IPython Console) navigate to the folder with the McStas NeXus event data:cd /path/to/folder
- Open the Python script editor:
View
->Script Window
- Copy the following Python code to the
Script Window
- Run reduction:
Execute
->Execute All
from mantid.simpleapi import *
# load McStas NeXus file
ws = Load('mccode.h5')
# Read the event data. Rebin and TOF conversion
sample = Rebin(ws[0],'10', False)
sample = ConvertUnits(sample, 'Wavelength')
binning = '1.75,0.05,16.5'
sample = Rebin(sample, binning)
# Read normalizaion data
mcstasMonitor = CloneWorkspace(mtd['Edet0.dat_ws'])
mcstasMonitor = ConvertToHistogram(mcstasMonitor)
mcstasMonitor = rebin(mcstasMonitor, binning)
monitor = CreateWorkspace(mcstasMonitor.dataX(0), mcstasMonitor.dataY(0), mcstasMonitor.dataE(0), UnitX='Wavelength')
# Reduce data to scattering cuvre I(q)
binningMASK = '0.0035,0.001,0.7'
Iq_1D = Q1D(sample, binningMASK, WavelengthAdj='monitor')
See Ref. [1] for full explanations of the specific Mantid methods used in this tutorial. For comparison, we have also included the scattering curve evaluated by SasView, a SANS data analysis tool [9], using the same material parameters as given in the McStas scattering sample “Sans_spheres”.
Figure 5: Mantidplot used reduced McStas event data. The Python script is copied to Script Window (left) and the associated reduced data I(q) is plotted and compared with a theoretical prediction using SasView (right).
In this section, we shall consider a more realistic McStas description of a neutron scattering instrument: the ISIS SANS2d beam line. A McStas instrument file of the base line for SANS2d can be found in the McStas neutron suites of instruments: ISIS_SANS2d.instr. To generate McStas event data for SANS2d ready to be loaded by Mantid we need to change the ISIS_SANS2d.instr file according to the McStas conventions (described above in the section Setup the McStas instrument to create a Mantid instrument). This implies adding the keywords and the associated McStas components: soruceMantid, sampleMantid and nD_Mantid_1. The resulting McStas instrument file we will denote ISIS_SANS2d_Mantid.instr. It can be downloaded from the McStas repository. For this tutorial, we shall also need to download the latest version of SANS_benchmark2.comp. It is the SANS scattering sample we will use for the instrument simulation. Run the McStas simulation as described above.
Figure 6: Mantid view on the neutron optics geometry used in the McStas instrument file. Use the method LoadEmptyInstrument in Mantid to display the IDF file. The IDF file must be generated by using mcdisplay with the option "--complete". This will render the complete instrument file in IDF xml file.
The SANS2D instrument has a curved neutron guide. See Fig. 6. The bending optics is included in the McStas description, but it poses a problem for Mantid, since the time-of-flight (TOF) conversion in Mantid assumes a straight flight path from source to sample. To by-pass this, we simply artificially introduce the sourceMantid component as a specific point in space without any neutron transport duties associated (i.e. just as an Arm). At the same time, we keep the ISIS source component at the origin, see Fig.7. In summary we have then kept the neutron transport correct, but adjusted the geometry (the IDF file) passed on to Mantid, such that the flight path from source to sample appears as a straight line to Mantid. See the instrument file ISIS_SANS2d_Mantid.instr for implementation details.
Figure 7: Mantid view on the neutron optics geometry used in the McStas instrument file with a zoom-in on the origin around the source.
Figure 8 below shows the resulting reduced data I(q) for running two simulations of the ISIS_SANS2D_Mantid.instr file. In both cases the sample consists of identical nano spheres with a radius of 150Å; i.e. monodisperse, homogeneous particles in dilute solution, where the particles are located randomly in the sample. In the first simulation, Sim1, we have kept the default instrument settings and run a McStas simulation with 1E8 rays. In the second simulation, Sim2, we have change the radius of slit S6 and collimation slit A2 to 1mm and run a McStas simulation with 3E10 rays. The McStas event data can then be reduced to get the scattering curve I(q) using the Python script as described above in the section Mantid reduction of McStas event data.
Figure 8: Plots of reduced data I(q) using Mantid for simulation Sim1 and Sim2 compared with the theoretical predictions from SasView.
In order for McStas to produce Mantid readable output, NeXus needs to be installed.
The latest binary NeXus installer for Windows can be found at the McStas web site. Download the NeXus file and follow the install instructions.
NeXus can be obtained from the Homebrew page. Installation is done from the command line.
- Open a browser and go to the webpage https://brew.sh. If brew is installed, then jump to item 3.
- Follow the install instructions. Type in a terminal:
$ /usr/bin/ruby -e "$(curl -fsSL https://raw.githubusercontent.com/Homebrew/install/master/install)"
- Ensure homebrew is fully updated
$ brew update && brew update
- Install hdf5
$ brew install hdf5
- Build and install nexusformat via the Legacy “science” tap
$ brew install brewsci/science/nexusformat --build-from-source
NeXus can be installed from the command line. (NeXus for other Linux distributions are installed in a similar manner.)
- Search for NeXus
$ apt-cache search libnexus
- Install NeXus
$ sudo apt-get install libnexus0v5 libnexus0-dev
NeXus can be installed from the command line. (NeXus for other Linux distributions are installed in a similar manner.)
- Search for NeXus
$ apt-cache search libnexus
- Install NeXus
$ apt-get install libnexus1 libnexus-dev
- Use mcrun --format=NeXus and compile with
CFLAGS=-g -O2 -lm -DUSE_NEXUS -l NeXus -I/usr/include/nexus
Optionally you may download the NeXus source code (https://github.com/nexusformat/code) and compile the library locally.
[1] Nielsen, T.R.; Markvardsen, A.J. and Willendrup, P. "McStas and Mantid integration". Journal of Neutron Research, vol. 18, no. 2-3, pp. 79-92, 2015. http://content.iospress.com/articles/journal-of-neutron-research/jnr026
[2] Willendrup P.; Farhi E. and Lefmann K. "McStas 1.7 - A New Version of the Flexible Monte Carlo Neutron Scattering Package", Physica B: Condensed Matter. Volume 350, Issues 1–3, Supplement, 15 July 2004, Pages E735–E737. https://doi.org/10.1016/j.physb.2004.03.193
[3] Willendrup, P.; Farhi E.; Knudsen E.; Filges U. and Lefmann K; "McStas: past, present and future". Journal of Neutron Research, vol. 17, no. 1, pp. 35-43, 2014. http://content.iospress.com/articles/journal-of-neutron-research/jnr004
[4] O. Arnold; et al., "Mantid—Data analysis and visualization package for neutron scattering and μSR experiments", Nuclear Instruments and Methods in Physics Research Section A, Volume 764, 11 November 2014, Pages 156-166. http://dx.doi.org/10.1016/j.nima.2014.07.029
[6] http://www.mantidproject.org
[7] http://www.nexusformat.org