Notifications
You must be signed in to change notification settings - Fork 0
/
gsw_CT_from_enthalpy_exact.m
executable file
·143 lines (126 loc) · 5.61 KB
/
gsw_CT_from_enthalpy_exact.m
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
function CT = gsw_CT_from_enthalpy_exact(SA,h,p)
% gsw_CT_from_enthalpy_exact Conservative Temperature from specific
% enthalpy of seawater
%==========================================================================
%
% USAGE:
% CT = gsw_CT_from_enthalpy_exact(SA,h,p)
%
% DESCRIPTION:
% Calculates the Conservative Temperature of seawater, given the Absolute
% Salinity, SA, specific enthalpy, h, and pressure p. The specific
% enthalpy input is calculated from the full Gibbs function of seawater,
% gsw_enthalpy_t_exact.
%
% Note that this function uses the full Gibbs function. There is an
% alternative to calling this function, namely
% gsw_CT_from_enthalpy(SA,h,p), which uses the computationally
% efficient 75-term expression for specific volume in terms of SA, CT
% and p (Roquet et al., 2015).
%
% INPUT:
% SA = Absolute Salinity [ g/kg ]
% h = specific enthalpy [ J/kg ]
% p = sea pressure [ dbar ]
% ( i.e. absolute pressure - 10.1325 dbar )
%
% SA & h need to have the same dimensions.
% p may have dimensions 1x1 or Mx1 or 1xN or MxN, where SA & h are MxN.
%
% OUTPUT:
% CT = Conservative Temperature ( ITS-90) [ deg C ]
%
% AUTHOR:
% Trevor McDougall and Paul Barker. [ [email protected] ]
%
% VERSION NUMBER: 3.05 (27th January 2015)
%
% REFERENCES:
% IOC, SCOR and IAPSO, 2010: The international thermodynamic equation of
% seawater - 2010: Calculation and use of thermodynamic properties.
% Intergovernmental Oceanographic Commission, Manuals and Guides No. 56,
% UNESCO (English), 196 pp. Available from http://www.TEOS-10.org
%
% McDougall, T.J., 2003: Potential enthalpy: A conservative oceanic
% variable for evaluating heat content and heat fluxes. Journal of
% Physical Oceanography, 33, 945-963.
%
% McDougall T.J. and S.J. Wotherspoon, 2013: A simple modification of
% Newton's method to achieve convergence of order 1 + sqrt(2). Applied
% Mathematics Letters, 29, 20-25.
%
% Roquet, F., G. Madec, T.J. McDougall, P.M. Barker, 2015: Accurate
% polynomial expressions for the density and specifc volume of seawater
% using the TEOS-10 standard. Ocean Modelling.
%
% The software is available from http://www.TEOS-10.org
%
%==========================================================================
%--------------------------------------------------------------------------
% Check variables and resize if necessary
%--------------------------------------------------------------------------
if ~(nargin == 3)
error('gsw_CT_from_enthalpy_exact: requires three inputs')
end
[ms,ns] = size(SA);
[mh,nh] = size(h);
[mp,np] = size(p);
if (mh ~= ms | nh ~= ns)
error('gsw_CT_from_enthalpy_exact: SA and h must have same dimensions')
end
if (mp == 1) & (np == 1) % p scalar - fill to size of SA
p = p*ones(ms,ns);
elseif (ns == np) & (mp == 1) % p is row vector,
p = p(ones(1,ms), :); % copy down each column.
elseif (ms == mp) & (np == 1) % p is column vector,
p = p(:,ones(1,ns)); % copy across each row.
elseif (ns == mp) & (np == 1) % p is a transposed row vector,
p = p.'; % transposed then
p = p(ones(1,ms), :); % copy down each column.
elseif (ms == mp) & (ns == np)
% ok
else
error('gsw_CT_from_enthalpy_exact: Inputs array dimensions do not agree; check p')
end %if
if ms == 1
SA = SA.';
h = h.';
p = p.';
transposed = 1;
else
transposed = 0;
end
%--------------------------------------------------------------------------
% Start of the calculation
%--------------------------------------------------------------------------
SA(SA < 0) = 0; % This line ensures that SA is non-negative
CT_freezing = gsw_CT_freezing(SA,p,0); % This is the CT freezing temperature
h_below_freeze = gsw_cp0; %This allows for water to be approx. 1C below the freezing temperature
h_freezing = gsw_enthalpy_CT_exact(SA,CT_freezing,p);
if any(h(:) < (h_freezing(:) - h_below_freeze)) %The input, seawater enthalpy h, is less than the enthalpy at the freezing temperature, i.e. the water is frozen
[I] = find(h < h_freezing);
SA(I) = NaN;
end
h_40 = gsw_enthalpy_CT_exact(SA,40*ones(size(SA)),p);
if any(h(:) > h_40(:)) % The input, seawater enthalpy h, is greater than the enthalpy when CT is 40 C
[I] = find(h > h_40);
SA(I) = NaN;
end
CT = CT_freezing + (40 - CT_freezing).*(h - h_freezing)./(h_40 - h_freezing); % First guess of CT
[dummy, h_CT] = gsw_enthalpy_first_derivatives_CT_exact(SA,CT,p);
%--------------------------------------------------------------------------
% Begin the modified Newton-Raphson iterative procedure
%--------------------------------------------------------------------------
CT_old = CT;
f = gsw_enthalpy_CT_exact(SA,CT_old,p) - h;
CT = CT_old - f./h_CT ; % this is half way through the modified Newton's method (McDougall and Wotherspoon, 2013)
CT_mean = 0.5*(CT + CT_old);
[dummy, h_CT] = gsw_enthalpy_first_derivatives_CT_exact(SA,CT_mean,p);
CT = CT_old - f./h_CT ; % this is the end of one full iteration of the modified Newton's method
% After 1 iteration of this modified Newton-Raphson iteration, the error in
% CT is no larger than 5x10^-14 degrees C, which is machine precision for
% this calculation.
if transposed
CT = CT.';
end
end