Notifications
You must be signed in to change notification settings - Fork 16
New issue
Have a question about this project? Sign up for a free GitHub account to open an issue and contact its maintainers and the community.
By clicking “Sign up for GitHub”, you agree to our terms of service and privacy statement. We’ll occasionally send you account related emails.
Already on GitHub? Sign in to your account
Q350 cannot be discovered and cannot connect #44
Comments
You can pass --pin for this. |
I'm getting the same error. Is the PIN equal to the password on the unit itself or is this something different? |
Not sure. It's what you also need to enter in the mobile app to register. |
Thank you for your fast responses. I changed the PIN but still get a NOT_ALLOWED error. |
Hi Michael, could it be that the PIN argument is not used in the code? Looking at line 86 of main.py you're only passing the found bridge and the UUID to the connect method. If the PIN is not passed this would explain why there is no difference in behavior between the different PINs? |
The pin is passed to cmd_register_app at line 97. To login, only the UUID is needed. It's only when registering that the pin needs to be passed. The library is using a DEFAULT_UUID of 000...1, maybe this is giving issues. You could try to change this, or pass another --uuid on the command line. It needs to be a random 32 char hexadecimal string. |
Got it working now with a test sample. Thanks! |
Can you indicate what the problem was and how you fixed it? This might help someone in the future :) |
Sure: I've created a short test script and this works fine now. `import asyncio from aiocomfoconnect import ComfoConnect async def main():
if name == "main": ` |
I assume the correct Python program is this one (the one above has a funny indentation and mispelled Note that import asyncio
from aiocomfoconnect import ComfoConnect
from aiocomfoconnect.const import VentilationSpeed
from aiocomfoconnect.sensors import SENSORS
async def main():
""" Basic example."""
uuid = '00000000001010188001144fd71def56'
local_uuid = '74FFBA365BB2E62C635349CE17881B09'
host = 'x.x.x.x'
pin = 'xxxx'
name = 'pythontest'
registered = False
# Connect to the bridge
comfoconnect = ComfoConnect(host, uuid)
try:
# Login
await comfoconnect.connect(local_uuid)
print("UUID is already registered: " + local_uuid)
registered = True
except:
print("UUID is not registered: " + local_uuid)
try:
# Register application
await comfoconnect.cmd_register_app(local_uuid, name, pin)
print(f"UUID {local_uuid} is now registered.")
except:
await comfoconnect.disconnect()
print("Registration failed. Please check the PIN.")
await comfoconnect.disconnect()
if registered:
def sensor_callback(sensor, value):
""" Print sensor updates. """
print(f"{sensor.name} = {value}")
comfoconnect = ComfoConnect(host, uuid, sensor_callback=sensor_callback)
await comfoconnect.connect(local_uuid)
# Register all sensors
for key in SENSORS:
await comfoconnect.register_sensor(SENSORS[key])
# Wait 2 minutes so we can see some sensor updates
await asyncio.sleep(120)
# Disconnect from the bridge
await comfoconnect.disconnect()
if __name__ == "__main__":
asyncio.run(main()) Yet, it fails for me, too, as does any command like It's a Q600, with a ComfoConnect Gateway firmware version U1.1.10 (I think there's a newer version, but I can't get a straight answer from Zehnder's support, which is abysmal). Should I report that in a new issue, or is that something being worked on? It looks like the latter. |
For me this is working at this moment. |
Yes, you said so before. Good for you, I guess. 😉 |
Hi,
The connection to my Q350 doesn't work. I have a feeling this is related to the PIN, but I don't think I can change this in the device. Error when connecting:
_python -m aiocomfoconnect --debug register --host 192.168.20.36
DEBUG:asyncio:Using proactor: IocpProactor
INFO:asyncio:Datagram endpoint local_addr=('0.0.0.0', 0) remote_addr=None created: (<_ProactorDatagramTransport fd=424>, <aiocomfoconnect.discovery.BridgeDiscoveryProtocol object at 0x0000021860064980>)
DEBUG:aiocomfoconnect.discovery:Socket has been created
DEBUG:aiocomfoconnect.discovery:Sending discovery request to 192.168.20.36:56747
DEBUG:aiocomfoconnect.discovery:Data received from ('192.168.20.36', 56747): b'\x12#\n\r192.168.20.36\x12\x10\x00\x00\x00\x00\x00\x10\x10\x18\x80\x01\x14O\xd7\x1d\xefV\x18\x01'
DEBUG:aiocomfoconnect.bridge:Connecting to bridge 192.168.20.36
DEBUG:asyncio:<asyncio.TransportSocket fd=508, family=2, type=1, proto=6, laddr=('192.168.20.100', 62312), raddr=('192.168.20.36', 56747)> connected to 192.168.20.36:56747: (<_ProactorSocketTransport fd=508 read=<_OverlappedFuture pending cb=[_ProactorReadPipeTransport._loop_reading()] created at C:\Users\mverh\AppData\Local\Programs\Python\Python312\Lib\asyncio\windows_events.py:506>>, <asyncio.streams.StreamReaderProtocol object at 0x00000218600B7F50>)
DEBUG:aiocomfoconnect.bridge:Connected to bridge 192.168.20.36
DEBUG:aiocomfoconnect.bridge:StartSessionRequest
DEBUG:aiocomfoconnect.bridge:Adding listener for event 1
DEBUG:aiocomfoconnect.bridge:TX 00000000000000000000000000000001 -> 00000000001010188001144fd71def56: 08032001 0801
type: StartSessionRequestType
reference: 1
takeover: true
DEBUG:aiocomfoconnect.bridge:RX 00000000001010188001144fd71def56 -> 00000000000000000000000000000001: 083510052001
type: StartSessionConfirmType
result: NOT_ALLOWED
reference: 1
DEBUG:aiocomfoconnect.bridge:Emitting for event 1_
Is the PIN the "password" that needs to be used when logging into the display on the device? If so, can I change the default PIN with a parameter, or do I need to adjust the code for this?
The text was updated successfully, but these errors were encountered: