Skip to content
New issue

Have a question about this project? Sign up for a free GitHub account to open an issue and contact its maintainers and the community.

By clicking “Sign up for GitHub”, you agree to our terms of service and privacy statement. We’ll occasionally send you account related emails.

Already on GitHub? Sign in to your account

respawn fails on HP servers #155

Open
dyasny opened this issue Nov 13, 2014 · 1 comment
Open

respawn fails on HP servers #155

dyasny opened this issue Nov 13, 2014 · 1 comment

Comments

@dyasny
Copy link

dyasny commented Nov 13, 2014

The previous run of hpacucli remains locking in memory, so a call to respawn will produce:

Error: Another instance of ACU is already running (possibly a service). Please
terminate the ACU application before running the ACU CLI.

In my scenario, there were no lockfiles to be found under /opt/compaq or any mutex references in /dev/shm. Nothing HP related in ps either, only thing that helps is a reboot, since the pxe environment has no strace for debugging

@ErwanAliasr1
Copy link
Contributor

As per http://uppayinix.blogspot.fr/2010/10/hpacucli-error-another-instance-of-acu.html, it seems to be related to a blocked semaphore.

If you have ti issue again, please provide a ps -a and ipcs -p.

Sign up for free to join this conversation on GitHub. Already have an account? Sign in to comment
Labels
None yet
Projects
None yet
Development

No branches or pull requests

2 participants