ergoCub 1.0 S/N:000 – Right hip pitch gives AEA encoder invalid data #1658

Closed
GiulioRomualdi opened this issue Oct 13, 2023 · 1 comment
Assignees
Labels
ergoCub 1.0 S/N:000 ergoCub robot (prototype)

Comments

@GiulioRomualdi
Copy link
Member

GiulioRomualdi commented Oct 13, 2023

Robot Name πŸ€–

ergoCub 1.0 S/N:000

Request/Failure description

We noticed that after finish the calibration the r_hip_pitch goes in HF with the MC AEA encoder data

Detailed context

image

Additional context

cc @G-Cervettini @isorrentino

How does it affect you?

No response

@GiulioRomualdi GiulioRomualdi added the ergoCub 1.0 S/N:000 ergoCub robot (prototype) label Oct 13, 2023
@github-actions github-actions bot changed the title Right hip pitch gives AEA encoder invalid data ergoCub 1.0 S/N:000 – Right hip pitch gives AEA encoder invalid data Oct 13, 2023
@AntonioConsilvio
Copy link
Contributor

Hi @GiulioRomualdi, I found the cable RLS0 (that connect the EMS EB6 with the AMO sensor) damaged.

II fixed it and the robot works properly now.

cc @sgiraz