Official client to use HTTP polling for firmware updates from NervesHub
NervesHub is an open-source firmware update server that works well with Nerves-based devices. A managed version is available at nerves-hub.org and it's possible to host your own.
NervesHub provides many of the features that you'd expect in a firmware update server. Fundamentally, devices connect to the server either by polling at a pre-configured interval or by joining a long-lived Phoenix channel. If a firmware update is available, NervesHub will provide a URL to the device and the device can update immediately or when convenient.
NervesHub does impose some requirements on devices and firmware that may require changes to your Nerves projects:
- Firmware images are cryptographically signed (both NervesHub and devices validate signatures)
- Devices are identified by a unique serial number
- Each device has its own SSL certificate for authentication with NervesHub
These changes enable NervesHub to provide assurances that the firmware bits that you intend to install on a set of devices make it to those devices unaltered.
The following sections will walk you through updating your Nerves project to work with the nerves-hub.org NervesHub server. Using your own NervesHub server will require setting URLs to point elsewhere and is not covered below to simplify first usage.
Many of the steps below may feel manual, but they can and are automated by NervesHub users to set up automatic firmware updates from CI and to manufacture large numbers of devices.
The nerves-hub.org NervesHub server is currently in
limited beta so it does not allow new users to sign up. However, you found these
docs and if you can use mix
and endure some API changes, you can join us.
In addition to the web site, NervesHub provides a command line interface (CLI). Some features are only available via the CLI. To enable the CLI in your project, addnerves_hub_cli to your dependency list:
defp deps do
[
{:nerves, "~> 1.3", runtime: false},
{:nerves_hub_cli, "~> 0.1", runtime: false}
...
] ++ deps(@target)
end
Run mix deps.get
to download the nerves_hub_cli
dependency.
Presumably you do not have an account yet. Create one by running:
mix nerves_hub.user register
If you already have an account, make sure that you have authenticated by running:
mix nerves_hub.user auth
The first step is to add nerves_hub_link_http
to your target dependencies in your
project's mix.exs
. Since NervesHub uses SSL certificates, the time must be set
on the device or certificate validity checks will fail. If you're not already
setting the time, add nerves_time
to
your dependencies. For example:
defp deps(target) do
[
{:nerves_runtime, "~> 0.9"},
{:nerves_hub_link_http, "~> 0.1"},
{:nerves_time, "~> 0.2"},
...
] ++ system(target)
end
Next, update your config.exs
so that the nerves_hub_link_http
library can help
provision devices. Do this by adding provisioning: :nerves_hub_link_http
to the
:nerves, :firmware
option like this:
config :nerves, :firmware,
provisioning: :nerves_hub_link_http
You can now use NervesHubLinkHTTP.update/0
to request any available updates from NervesHub.
A NervesHub product groups devices that run the same kind of firmware. All devices and firmware images have a product. NervesHub provides finer grain mechanisms for grouping devices, but a product is needed to get started.
By default, NervesHub uses the :app
name in your mix.exs
for the product
name. If you would like it to use a different name, add a :name
field to your
Mix.Project.config()
. For example, NervesHub would use "My Example" instead of
"example" for the following project:
def project do
[
app: :example,
name: "My Example"
]
end
For the remainder of this document, though, we will not use the :name
field
and simply use the product name example
.
Create a new product on NervesHub by running:
mix nerves_hub.product create
NervesHub requires cryptographic signatures on all managed firmware. Devices receiving firmware from NervesHub validate signatures. Since firmware is signed before uploading to NervesHub, NervesHub or any service NervesHub uses cannot modify it.
Firmware authentication uses Ed25519 digital signatures. You need to create at least one public/private key pair and copy the public key part to NervesHub and to devices. NervesHub tooling helps with both. A typical setup has multiple signing keys to support key rotation and "development" keys that are not as protected.
Start by creating a devkey
firmware signing key pair:
mix nerves_hub.key create devkey
On success, you'll see the public key. You can confirm using the NervesHub web interface that the public key exists. Private keys are never sent to the NervesHub server. NervesHub requires valid signatures from known keys on all firmware it distributes.
The next step is to make sure that the public key is embedded into the firmware image. This is important. The device uses this key to verify the firmware it receives from a NervesHub server before applying the update. This protects the device against anyone tampering with the firmware image between when it was signed by you and when it is installed.
All firmware signing public keys need to be added to your config.exs
. Keys
that are stored locally (like the one we just created) can be referred to by
their atom name:
config :nerves_hub_link_http,
fwup_public_keys: [:devkey]
If you have keys that cannot be stored locally, you will have to copy/paste their public key:
config :nerves_hub_link_http,
fwup_public_keys: [
# devkey
"bM/O9+ykZhCWx8uZVgx0sU3f0JJX7mqnAVU9VGeuHr4="
]
The nerves_hub_link_http
dependency converts key names to public keys at compile time.
If you haven't compiled your project yet, run mix firmware
now. If you have
compiled it, mix
won't know to recompile nerves_hub_link_http
due to the configuration
change. Force it to recompile by running:
mix deps.compile nerves_hub_link_http --force
mix firmware
While not shown here, you can export keys for safe storage. Additionally, key
creation and firmware signing can be done outside of the mix
tooling. The only
part that is required is that the firmware signing public keys be added to your
config.exs
and to the NervesHub server.
Uploading firmware to NervesHub is called publishing. To publish firmware start by calling:
mix firmware
Firmware can only be published if has been signed. You can sign the firmware by running.
mix nerves_hub.firmware sign --key devkey
Firmware can also be signed while publishing:
mix nerves_hub.firmware publish --key devkey
In this example we will create a device with a hardware identifier 1234
. The
device will also be tagged with qa
so we can target it in our deployment
group. We will select y
when asked if we would like to generate device
certificates. Device certificates are required for a device to establish a
connection with the NervesHub server.
$ mix nerves_hub.device create
NervesHub organization: nerveshub
identifier: 1234
description: test-1234
tags: qa
Local user password:
Device 1234 created
Would you like to generate certificates? [Yn] y
Creating certificate for 1234
Finished
It is important to note that device certificate private keys are generated and
stay on your host computer. A certificate signing request is sent to the server,
and a signed public key is passed back. Generated certificates will be placed in
a folder titled nerves-hub
in the current working directory. You can specify a
different location by passing --path /path/to/certs
to NervesHubCLI mix
commands.
NervesHub certificates and hardware identifiers are persisted to the firmware
when the firmware is burned to the SD card. To make this process easier, you can
call nerves_hub.device burn IDENTIFIER
. In this example, we are going to burn
the firmware and certificates for device 1234
that we created.
mix nerves_hub.device burn 1234
Your device will now connect to NervesHub when it boots and establishes an network connection.
Deployments associate firmware images to devices. NervesHub won't send firmware to a device until you create a deployment. First find the UUID of the firmware. You can list the firmware on NervesHub by calling:
mix nerves_hub.firmware list
Firmwares:
------------
product: example
version: 0.3.0
platform: rpi3
architecture: arm
uuid: 1cbecdbb-aa7d-5aee-4ba2-864d518417df
In this example we will create a new deployment for our test group using firmware
1cbecdbb-aa7d-5aee-4ba2-864d518417df
.
mix nerves_hub.deployment create
NervesHub organization: nerveshub
Deployment name: qa_deployment
firmware uuid: 1cbecdbb-aa7d-5aee-4ba2-864d518417df
version condition:
tags: qa
Local user password:
Deployment test created
Here we create a new deployment called qa_deployment
. In the conditions of this
deployment we left the version condition
unspecified and the tags
set to
only qa
. This means that in order for a device to qualify for an update, it
needs to have at least the tags [qa]
and the device can be coming from any
version.
At this point we can try to update the connected device.
Start by bumping the application version number from 0.1.0
to 0.1.1
. Then,
create new firmware:
mix firmware
We can publish, sign, and deploy firmware in a single command now.
mix nerves_hub.firmware publish --key devkey --deploy qa_deployment
If you see the following in your logs:
14:26:06.926 [info] ['TLS', 32, 'client', 58, 32, 73, 110, 32, 115, 116, 97, 116, 101, 32, 'cipher', 32, 'received SERVER ALERT: Fatal - Unknown CA', 10]
This probably indicates that the signing certificate hasn't been uploaded to nerves-hub.org so the device can't be authenticated. Double check that you ran:
mix nerves_hub.ca_certificate register my-signer.cert
Another possibility is that the device wasn't provisioned with the certificate that's on nerves-hub.org.