10 changes: 10 additions & 0 deletions Hybrid_SHXXRT_Holding-Register.tsv
Original file line number Diff line number Diff line change
Expand Up @@ -56,3 +56,13 @@ _address name description unit type len factor offset formula role room poll wp
33216 Forced Charging End Time 2h 0-23 h uint16be 1 1 0 value true false false false
33217 Forced Charging End Time 2min 0-59 min uint16be 1 1 0 value true false false false
33218 Forced Charging Target SOC2 0-100 % uint16be 1 1 0 value true false false false
33540 WB charging mode wb charging mode (160=fastCharge 161=pvSurplus 162=quantity&timeBased 163=userDefined) uint16be 1 1 0 value true false false false
33541 WB charching quantity wb charching quantity (e.g. 12kwh = 120) uint16be 1 1 0 value true false false false
33542 WB charching duration wb charching duration uint32be 2 1 0 value true false false false
33543 WB WB ? uint32be 2 1 0 value true false false false
33544 WB charching power user defined charge wb user defined charching (eg. 10A = 100) uint16be 1 1 0 value true false false false
33545 WB user defined charge start time wb user defined charge start time uint32be 2 1 0 value true false false false
33546 WB WB ? uint32be 2 1 0 value true false false false
33547 WB user defined charge end time wb user defined charge end time uint32be 2 1 0 value true false false false
33548 WB WB ? uint32be 2 1 0 value true false false false
33549 WB surplus power from grid wb surplus ??? 85=powerFromGrid 170=? 1 1 0 value true false false false