看了下 6200 的 UM,手册中 PID 写的是
0x0002
,但我手上 6300 的板子 PID 也是0x0002
,应该是手册描述有误,先给你合了。感谢 PR。There was a problem hiding this comment.
Choose a reason for hiding this comment
The reason will be displayed to describe this comment to others. Learn more.
刚看到,6200我开始是没看手册的,直接尝试使用发现一直报错无法打开USB设备。改了代码打印USB信息,然后找到同vid的设备有一个pid是
0x0003